GSM VAC2 Installers Manual

Embed Size (px)

Citation preview

  • 8/7/2019 GSM VAC2 Installers Manual

    1/30

    EDGARSSON SECURITY DESIGNS

    GSM-VAC2+VOICE and SMS DIAL-SYSTEM onGSM NETWORK

    INSTALLERS MANUALV1.1f

    10/04/07

  • 8/7/2019 GSM VAC2 Installers Manual

    2/30

    _____________________________________________________________________________

    2

  • 8/7/2019 GSM VAC2 Installers Manual

    3/30

    Quick Start Guide

    1, Put the SIM card into your phone

    2, Check that you have credit on the SIM.

    3, Make sure that you can dial a number without having to enter a PIN number or keypadunlock.

    4, Enter the following names and numbers into the SIM phone book.

    ( Letters have to be capitals )( Make sure these are stored in the SIM card and not in the Phones memory.

    You may need to copy, transfer or save to the SIM card

    Name TL1 NumberYour Mobile NumberNameLK1 Number1

    NameIP1Number0Name #1AlarmNumber 1

    5, Put SIM card into GSM-VAC2+ SIM holder.

    6, Connect 12 Volts to Screw terminal marked +12VConnect 0 Volts to the 0V screw terminal to the right of the 12V terminal ( GND )

    7, Turn on 12 Volt Supply.

    8, Green LED lamp will be OnBlue LED will come on and go off.

    After around 30 seconds the blue LED will start to flash ( the number of flashes indicatesGSM network signal strength, 1 flash is poor, 5 is max )

    9, Press and continue to hold down the push button to record message 1, the buttonnearest to the top of the unit, when the red LED comes on, speak your message into the

    Microphone, remove your finger from the button.Press the same button momentarily to listen to the message.

    10. When the blue LED is flashing, indicating the the unit is connected to the network,connect input 1 ( IN1 ) to 0 Volts for 5 seconds.

    11, The Green LED will flash, the blue LED will be on, the unit is now sending a text andvoice message to your phone.

    12, Your phone will receive a text message.

    13, Your phone will ring, answer it and you will hear your voice message, press # or 88 tocancel the alarm. You will hear a beep and the call will end.

    _____________________________________________________________________________

    3

  • 8/7/2019 GSM VAC2 Installers Manual

    4/30

    FEATURES

    Builtin GSM module

    4 alarm inputs

    4 remote control outputs 4 voice messages (maximum length of 10 seconds for each input)

    Shortened message (SMS) for each alarm input

    Memory stores up to 10 different telephone numbers

    Programmable dialling number sequence. Listen-in function ( optional )

    3 LED displays enable easy monitoring

    Builtin speaker and microphone

    Activated dialling sequence can be stopped by means of user's

    telephone unit

    New features of the GSM-VAC2+

    Download programming by SMS

    Input and Output status checking by SMS and DTMF command

    Outputs remote control by SMS, CLIP and DTMF command

    System activating and deactivating by SMS, CLIP and DTMF command

    Phone book memory clear by SMS command

    Full print out of programming parameters by SMS

    Print out by parameters groups Special security codes (telephone numbers) to enter in program

    Call back device checking

    Output Alarm can directly activate alarm output

    Input filter can be set from 2 up to 24 seconds

    Telephone numbers (10) which give the ability to activate the outputs, switch the system

    ON/OFF or make call back device checking by using the CLIP

    Security telephone numbers (10) to enter into programming or remote control mode

    _____________________________________________________________________________

    4

  • 8/7/2019 GSM VAC2 Installers Manual

    5/30

    1. DESCRIPTION

    The GSM-VAC2 is a new kind of a mobile voice and SMS dialling system. The phonememory in the form of a SIM card is used either to store telephone numbers or to programcertain parameters. It is possible to record four different messages and send them to 10different telephone numbers. The alarm inputs can be normal open(N.O.) and are thustriggered by a positive (+12V) or a negative pulse (GND); or they can be normal close(+12V or GND lost). Each alarm input enables us to send a pre-recorded voice message,an SMS or both.The GSM-VAC2 has also four outputs giving the user the ability to control a certain systemfrom distance.

    2. PURPOSE and APPLICATION

    The GSM-VAC2 mobile unit can provide us with different information on the state of thealarm mounted on the protected object. It can also transmit other useful informationimportant for operating applications such as:

    vending machines

    various engines out of the reach of manual operation

    home care or emergency alarm

    car and boat alarm transmitter

    temperature regulation by means of a sensor

    _____________________________________________________________________________

    5

  • 8/7/2019 GSM VAC2 Installers Manual

    6/30

    3. CONNECTION DIAGRAM

    _____________________________________________________________________________

    6

  • 8/7/2019 GSM VAC2 Installers Manual

    7/30

    4. GSM-VAC2 PROGRAMMING MODE

    All data, programming values and telephone numbers need to be stored in the phone booklocated on the SIM card. Therefore the use of a personal mobile phone is recommended.

    5.1 HOW TO PROGRAM TELEPHONE NUMBERS

    5.2 PROGRAMMING TABLE

    GSM-VAC2 PROGRAMMING TABLE

    SIM CARD PHONE BOOK

    NAMENUMBER

    (DEFAULT)DESCRIPTION

    TL0 1st telephone number

    TL1 2nd telephone number

    TL2 3rd telephone number

    TL3 4th telephone number

    TL4 5th telephone number

    TL5 6th telephone number

    TL6 7th telephone number

    TL7 8th telephone number

    TL8 9th telephone number

    TL9 10th telephone number

    GSM-VAC2 can send only a pre-recorded voice message, an 18 characterSMS message

    or both. If the corresponding name ends with the letter C, only a voice message is sent;and if the name ends with the letter S, only an SMS is sent.

    Example: We wish to send a voice and an SMS message to the first telephone number,only a voice message to the second one and only an SMS message to the third one. (Seethe table below.)

    GSM-VAC2PROGRAMMING TABLE

    SIM CARD PHONE BOOK

    NAMENUMBER

    (DEFAULT)DESCRIPTION

    TL0 1st telephone number (voice & SMS message)

    TL1C 2nd telephone number (voice message only)

    TL2S 3rd telephone number (SMS message only)

    Do not send text messages to land lines.Very important Make sure you name the first telephone number TL0 and not TLO.i.e. a zero and not a letter O.The unit will not operate with old style Orange SIMs with 90 memory positions.

    _____________________________________________________________________________

    7

  • 8/7/2019 GSM VAC2 Installers Manual

    8/30

    4.3

    HOW TO PROGRAM INPUT STATUS

    Alarm and reset input can be triggered in 4 different ways. The status of the input can either benormally closed (N.C) or normally open (N.O.) with positive (+ 12V) or negative (GND) voltage.

    A text message can also be sent when the input returns to the non alarm state. To get return SMSuse IP=4,5 or 6.

    IP = 0 Normal Open triggered with negative voltage (GND)

    IP = 1 Normal Close breaking negative or positive voltage loop IP = 2 Normal Open triggered with positive voltage (+ 12VDC)

    IP = 3 Input disable

    IP = 4 = IP = 0 + input reset SMS

    IP = 5 = IP = 1 + input reset SMS

    IP = 6 = IP = 2 + input reset SMS

    5.3.1 TYPICAL INPUT CONNECTIONS

    5.3.2 PROGRAMMING TABLE FOR INPUT STATUS

    GSM-VAC2PROGRAMMING TABLE

    SIM CARD PHONE BOOK

    NAMENUMBER

    (DEFAULT)DESCRIPTION

    IP0 0 Input status for RST (reset)

    IP1 0 Input status for alarm input 1

    IP2 0 Input status for alarm input 2

    IP3 0 Input status for alarm input 3

    IP4 0 Input status for alarm input 4

    _____________________________________________________________________________

    8

  • 8/7/2019 GSM VAC2 Installers Manual

    9/30

    5.4 HOW TO PROGRAM OUTPUT STATUS

    The GSM-VAC2 device has four open collector outputs and each of them can be

    programmed through network in a different way: as a bi-stable or mono-stable output. Oneof them can be programmed so as to signal certain failure on the main device or to notifyus about the expiring validity of the SIM card.

    5.4.1 TYPICAL CONNECTION OF AN OUTPUT

    5.4.2 PROGRAMMING TABLE FOR OUTPUT STATUS

    GSM-VAC2 PROGRAMMING TABLE

    SIM CARD PHONE BOOK

    NAMENUMBER

    (DEFAULT)DESCRIPTION

    OP1 0 Status for the 1st output - disabled

    OP2 0 Status for the 2nd output - disabled

    OP3 0 Status for the 3rd output disabledOP4 0 Status for the 4th output - disabled

    OP (x) = 1 bi-stable ON/OFF modeOP (x) = 2 240 mono-stable (pulse length in seconds)OP (x) = 241 GSM network failure (H/L)OP (x) = 242 GSM network failure (L/H)OP (x) = 243 warning notice on the expiring validity of the SIM card (H/L)OP (x) = 244 warning notice on the expiring validity of the SIM card (L/H)

    _____________________________________________________________________________

    9

  • 8/7/2019 GSM VAC2 Installers Manual

    10/30

    5.5 INPUTS AND TELEPHONE NUMBERS LINKING

    It is possible to link each number or any combination of numbers to any of the four corresponding

    inputs. The link LK0 is specially designed for SIM card refill SMS warning message.

    5.5.1 PROGRAMMING TABLE FOR LINKING THE INPUTS AND TELEPHONE NUMBERS

    GSM-VAC2 PROGRAMMING TABLE

    SIM CARD PHONE BOOK

    NAMENUMBER

    (DEFAULT)DESCRIPTION

    LK0 Refill SIM SMS (#0) & telephone No. link (TL0 - TL9)

    LK1 Input & telephone No. link for 1st alarm input (TL0 - TL9)

    LK2 Input & telephone No. link for 2nd alarm input (TL0 - TL9)

    LK3 Input & telephone No. link for 3rd alarm input (TL0 - TL9)

    LK4 Input & telephone No. link for 4th alarm input (TL0 - TL9)

    LK5 Test SMS and telephone No. link (TL0 - TL9)

    Example: Alarm on the first input should call the first, the third and the fourth telephonenumber.

    GSM-VAC2PROGRAMMING TABLESIM CARD PHONE BOOK

    NAMNUMBER

    (DEFAULT)DESCRIPTION

    LK1 023 Input & telephone No. link for 1st alarm input (TL0, TL2, TL3)

    5.6 INPUT DELAY BEFORE DIALLING

    The activation of the dialling procedure can be for a defined period of time (maximum of240 seconds) delayed on each alarm input. The default value is set to "0" having nodelay before the beginning of the dialling procedure on all alarm inputs.

    5.6.1 PROGRAMMING TABLE TO DEFINE THE DELAY BEFORE DIALLING PROCEDURE

    GSM-VAC2 PROGRAMMING TABLE

    SIM CARD PHONE BOOK

    NAMENUMBER

    (DEFAULT)DESCRIPTION

    DL1 0 Delay before dialling for the 1st alarm input (0 240)

    DL2 0 Delay before dialling for the 2nd alarm input (0 240)

    DL3 0 Delay before dialling for the 3rd alarm input (0 240)

    DL4 0 Delay before dialling for the 4thalarm input (0 240)

    The period of time for the delay of each input varies from 0 to 240 seconds.

    _____________________________________________________________________________

    10

  • 8/7/2019 GSM VAC2 Installers Manual

    11/30

    5.7 GSM-VAC2 SET-UP PARAMERTERS

    RED repetition of calling sequences. With the number from 1 to 9 we define howoften the sequence is repeated in case the number is busy or not answered. Thedefault value is set to number 3.

    CLP hidden telephone number. This function (0 value) is used in order toconceal the telephone number of the device. The default value is set to 1 whichmeans that the number is displayed.

    RFL SIM card validity. The period of valid operating time varies with differentGSM network providers. The value can be programmed between 1 36, whereasdays represent multiplication of the mentioned value by 10. The default value doesnot presume any kind of expiry warning.

    Example: If we want to get an expiry warning message after 90 days, we shouldenter the number 9.

    RFT Temporary validity of theSIM card. This function is predefined on the SIMcard memory from the micro controller on the SIM card location 98. The user canonly change it when the RFL time is not regular (due to power failure or some otherconstant operating mode ).

    PTM A test SMS is sent periodically. The UNIT can send the test message in theinterval ranging from 1hour up to 240 hours.Example: if the PTM value is set to 12, the numbers linked to LK5 get a testmessage every 12 hours.

    5.7.1 PROGRAMMING TABLE FOR GSM-VAC2 SET-UP PARAMERTERS

    PROGRAMMING TABLE

    SIM CARD PHONE BOOK

    NAMENUMBER

    (DEFAULT)DESCRIPTION

    RED 3 Number of dialling attempts (1 9)

    CLP 1 Hidden telephone number (1= displayed, 0 = hidden)

    RFL Empty SIM card time validity (1 36) 1 = 10days, 36 = 360days

    RFT Temporary validity of the SIM card

    PTM Empty Periodic test SMS - disabled

    5.8 SMS MESSAGES TRANSLATOR

    _____________________________________________________________________________

    11

  • 8/7/2019 GSM VAC2 Installers Manual

    12/30

    The GSM-VAC2 can send a very short SMS message via each alarm input. The defaultmessage is English, but it is possible to formulate the notice in any other language.Different messages, being no longer than 18 characters, can be defined for each alarminput. Between words it is necessary to use _ instead of the space character.Example: ALARM_ON_INPUT

    5.8.1 SMS MESSAGES PROGRAMMING TABLE

    PHONE BOOK NAME1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20# 0 R E F I L L _ S I M _ C A R D# 1 A L A R M _ I N _ P R O G R E S S# 2 F I R E _ I N _ P R O G R E S S# 3# 4# 5 P K N 4 _ P E R I O D I C _ T E S T

    Normally, when we want to store the SMS text, the telephone number needs to beentered. Since the latter is required only because of the basic design of the phone bookmemory, it is not important what kind of a number we enter.

    Each text starts with a twocharacter command: # and number:

    #0 text for SIM card refill default = refill SIM in days#1 text for 1st alarm input default = alarm on input#2 text for 2nd alarm input default = alarm on input

    #3 text for 3rd

    alarm input default = alarm on input#4 text for 4th alarm input default = alarm on input#5 text for periodic test default = periodic test

    5. RECORDING AND LISTENING TO VOICE MESSAGE

    _____________________________________________________________________________

    12

  • 8/7/2019 GSM VAC2 Installers Manual

    13/30

    The memory of each alarm input enables us to record our own voice message in the totallength of 10 seconds. The device is namely equipped with a microphone and a speaker,giving us the option to listen to what we have recorded. The speaker can be switched offby removing the jumper JP1 compound.

    Recording process:

    1. Press PLAY/REC key (1-4) and hold it as long as the LED3 display is lit.2. Start speaking.3. Release key message recording process finished.4. Check recorded message by quickly pressing the (1-4) key.

    Erasing:

    Press PLAY/REC key (1-4) and hold it as long as the LED3 display is lit, then stoprecording.Follow the same procedure for all four messages.

    7. START UP

    Insert SIM card to be used for GSM-VAC2 in your personal mobile phone.

    Enter telephone numbers and the required operating parameters in SIM memory

    Insert SIM card in the GSM module ON the GSM-VAC2 device.

    Connect alarm inputs and outputs

    Connect device to source voltage.

    Record voice messages.

    Wait until LED1 starts flashing. GSM-VAC2 s now ready to operate.

    8. LED DISPLAY

    LED1 Blue - Flashing: - Within GSM signal power. The number of flashes ranging from 1 (poor) to 5(very good) shows quality of the GSM network signal

    -

    LED2 Green - Flashing:1 alarm on input 12 alarm on input 23 alarm on input 34 alarm on input 4

    LED3 redHelps to control recording and playback of voice message.Turned on: Message being recorded.Flashing: Recorded message being listened.

    9. GSM-VAC2 REMOTE COMMANDS

    _____________________________________________________________________________

    13

  • 8/7/2019 GSM VAC2 Installers Manual

    14/30

    We can call the device from any phone and according to that it answers only if thecalling number is in the phone book from TL0 to TL4. This is made with a short beep.

    NOTE:

    ONLY TELEPHONE NUMBERS STORED UNDER THE NAME TL0

    TL4 CAN ENTER THE REMOTE MODE!

    9.1 REMOTE COMMAND TABLE

    REMOTECOMMAND

    ACTION DESCRIPTION

    00 All outputs OFF

    01 Play message 1

    02 Play message 2

    03 Play message 3

    04 Play message 410 Output 1 OFF (bi-stable)

    11 Output 1 ON (bi-stable) or ON for mono-stable

    12 Check the output 1 state (1 beep=ON, 3 beeps=OFF)

    20 Output 2 OFF (bi-stable)

    21 Output 2 ON (bi-stable) or ON for mono-stable

    22 Check the output 2 state (1 beep=ON, 3 beeps=OFF)

    30 Output 3 OFF (bi-stable)

    31 Output 3 ON (bi-stable) or ON for mono-stable

    32 Check the output3 state (1 beep=ON, 3 beeps=OFF)

    40 Output 4 OFF (bi-stable)

    41 Output 4 ON (bi-stable) or ON for mono-stable

    42 Check the output4 state (1 beep=ON, 3 beeps=OFF)

    90 Valid SIM counter set to RFL value (after SIM refill)

    99 Listen-in ON (optional)

    * Don't call this tel. number again (tel. no. from TL0 - TL9)

    # OR 88 Cancel the dialling procedure (only tel. no. from TL0 - TL4)

    Important To terminate Listen in mode key 01 to play message 1.If you forget, the next time the dialler calls it will still be in listen-in mode and will not playthe speech message.

    10. TECHNICAL SPECIFICATION

    _____________________________________________________________________________

    14

  • 8/7/2019 GSM VAC2 Installers Manual

    15/30

    Power supply...13,8V DC (+/- 15%) Current consumption (idle mode)..50 mA Current consumption (idle mode)..350 mA Dual band GSM module..900/1800 MHz Number of inputs..4 Number of outputs4

    Number of voice messages....4 Total length of recording time.....40 second Number of SMS messages. 6 PCB dimensions...........105 x 76 mm Box dimensions...........................................................108 x165 x 56 mm

    _____________________________________________________________________________

    15

  • 8/7/2019 GSM VAC2 Installers Manual

    16/30

    GSM-VAC2 PLUS new parameters description

    OUTPUT ALARM OA

    If you want to activate a local alarm (siren) you can program any GSM-VAC2 PLUS output for this

    function.

    Type of the Output (ON/OFF or pulse time) is determinate with parameter OP (see the GSM-VAC2user manual).

    Also the outputs can be controlled remotely.

    OA parameters programming directly on SIM card

    Example:

    Input 1 (IN1) and Input2 (IN2) will activate the first Output (OUT1), Input 3 (IN3) will activate the

    second Output (OUT2) and Input 4 (IN4) will activate the third output (OUT3).

    It is possible to choose different combinations between outputs and inputs

    GSM-VAC2 - GSM PROGRAMMING TABLE

    SIM CARD PHONE BOOK

    NAME NUMBER* DESCRIPTION

    OA1 11 Input 1 will trigger the Output 1

    OA2 11 Input 2 wi ll trigger the Output 1

    OA3 21 Input 3will trigger the Output 2

    OA4 31 Input 4will trigger the Output 3

    *NOTE: The first digit is output number and the second must be always 1.

    OA parameters programming by SMS

    For the above example send the following SMS to GSM-VAC2 PLUS:

    ;OA1=11;OA2=11;OA3=21;OA4=31;

    _____________________________________________________________________________

    16

  • 8/7/2019 GSM VAC2 Installers Manual

    17/30

    INPUT FILTER IF

    Parameter IF determinate length of the pulse, that is required to create the alarm. The pulse time can

    be from 2 seconds up to 24 seconds.

    IF parameters programming directly on SIM card

    GSM-VAC2 - GSM PROGRAMMING TABLE

    SIM CARD PHONE BOOK

    NAME NUMBER DESCRIPTION

    IF0 1 Default IF filter is 2 seconds RST input

    IF1 1 Default IF filter is 2 seconds input 1

    IF2 1 Default IF filter is 2 seconds input 2

    IF3 1 Default IF filter is 2 seconds input 3

    IF4 1 Default IF filter is 2 seconds input 4

    Example:

    Input filter 1 (IF1) will be 2 second and Input filter 2 (IF2) will be 24 seconds

    GSM-VAC2 - GSM PROGRAMMING TABLE

    SIM CARD PHONE BOOK

    NAME NUMBER DESCRIPTION

    IF1 2 Pulse length is 2 second

    IF2 24 Pulse length is 24 seconds

    IF parameters programming by SMS

    For the above example send the following SMS to GSM-VAC2 PLUS:

    ;IF1=2;IF2=24;

    CLIP TELEPHONE NUMBERS TO

    Telephone numbers stored into the phone book from TO0 to TO9 can manage following functionsusing CLIP without any GSM call cost.

    _____________________________________________________________________________

    17

  • 8/7/2019 GSM VAC2 Installers Manual

    18/30

    - Trigger one of the GSM-VAC2 PLUS Output (parameter 1-4)- Switch the system ON/OFF (parameter 0)

    - System control with Call back function (parameter 5)

    -

    NOTE: With one telephone number it is only possible to use one of these 3 functions!

    When we use any of the CLIP function it is necessary to hang-up the call after the first ring.TO parameters programming directly on SIM card

    GSM-VAC2 - GSM PROGRAMMING TABLE

    SIM CARD PHONE BOOK

    NAME NUMBER DESCRIPTION

    TO0:X 1st CLIP telephone number

    TO1:X 2nd CLIP telephone number

    TO2:X 3rd CLIP telephone number

    TO3:X 4th CLIP telephone number

    TO4:X 5th CLIP telephone number

    TO5:X 6th CLIP telephone number

    TO6:X 7th CLIP telephone number

    TO7:X 8th CLIP telephone number

    TO8:X 9th CLIP telephone number

    TO9:X 10th CLIP telephone number

    X=1-4 Out1 to Out 4

    X=0 System ON/OFF

    X=5 Call back function

    Example:

    TO0 will trigger Out3, TO1 will switch the system ON/OFF and TO2 will make a call back.

    GSM-VAC2 - GSM PROGRAMMING TABLE

    SIM CARD PHONE BOOK

    NAME NUMBER DESCRIPTION

    TO1:3 0779 250299 1st CLIP telephone number

    TO1:0 01437 56390 2nd CLIP telephone number

    TO2:5 0779 118671 3rd CLIP telephone number

    TO parameters programming by SMS

    For the above example send the following SMS to GSM-VAC2 PLUS:

    ;TO0:3=0779250299;TO1:0=0143756390;TO2:5=0779118671;

    SECURITY TELEPHONE NUMBERS TK

    WARNING: In the previous version (GSM-VAC2) TL numbers (TL0..TL9) were the numbers to

    call out (for alarm voice messages) AND the numbers for security access / remote control purposes.

    In the GSM-VAC2+ TL numbers are ONLY the numbers to call out (for voice messages).Only telephone numbers, stored into the phone book from TK0 TK9 can enter the programming

    and remote control of the GSM-VAC2+ (dialling the GSM-VAC2+ No. or sending the SMS).

    _____________________________________________________________________________

    18

  • 8/7/2019 GSM VAC2 Installers Manual

    19/30

    Telephone numbers are divided in two groups:TK0 TK4 These telephone numbers have full access into programming and remote control mode;

    TK5 TK9These telephone numbers can not access programming mode but they can use other

    remote control functions;

    TK parameters programming directly on SIM card

    GSM-VAC2 - GSM PROGRAMMING TABLE

    SIM CARD PHONE BOOK

    NAME NUMBER DESCRIPTION

    TK0 1st security telephone number

    TK1 2nd security telephone number

    TK2 3rd security telephone number

    TK3 4th security telephone number

    TK4 5th security telephone number

    TK5 6th security telephone number

    TK6 7th security telephone number

    TK7 8th security telephone number

    TK8 9th security telephone number

    TK9 10th security telephone number

    Example:

    Youd like to have 2 telephone numbers for full access and 2 telephone numbers for partly access:

    GSM-VAC2 - GSM PROGRAMMING TABLE

    SIM CARD PHONE BOOK

    NAME NUMBER DESCRIPTION

    TK0 077071347 1st security telephone number

    TK1 077023222 2nd security telephone number

    TK5 077034040 5th security telephone number

    TK6 077077170 6th security telephone number

    Telephone numbers stored under TK0 and TK1 will have full access to the GSM-VAC2 PLUS and

    telephone numbers stored under TK5 and TK6 will have only partly access to the GSM-VAC2+.

    TK parameters programming by SMS

    For the above example send the following SMS to GSM-VAC2 PLUS:;TK0=077071347;TK1=077023222;TK5=077034040;TK6=077077170;

    NOTE: Before programming the first TK number on the SIM, anyone can get into the GSM-

    VAC2+ programming and remote mode but after TK programming only TK stored numbers!LISTEN-IN MICROPHONE SENSITIVITY ADJUSTING - MIC

    If we use the external Listen-In microphone or Duplex voice module HA200we can adjust the

    sensitivity of the microphone from the level 0 (minimum) to the level 24 (maximum). The default

    value is 5.MIC parameters programming directly on SIM card

    GSM-VAC2 - GSM PROGRAMMING TABLE

    _____________________________________________________________________________

    19

  • 8/7/2019 GSM VAC2 Installers Manual

    20/30

    SIM CARD PHONE BOOK

    NAME NUMBER DESCRIPTION

    MIC 1 External microphone sensitivity

    MIC parameter programming by SMS

    ;MIC=1;SMS COMAND DESCRIPTION

    NOTE: For using the SMS command you must use ; on the beginning and on the end of the

    SMS command.

    Use the CAPITAL letters for the SMS command.

    PRINT-OUT OF THE PARAMETERS

    ;PRALL;

    Print All sending this command to the GSM-VAC2 PLUS you will get 12 SMS back from it with

    all parameters that are currently programmed on the SIM.

    _____________________________________________________________________________

    20

  • 8/7/2019 GSM VAC2 Installers Manual

    21/30

    ;PRTL;

    Print TL - sending this command to the GSM-VAC2 PLUS you will get back the SMS with all

    currently programmed telephone numbers (TL0 TL9).

    ;PRLK;

    Print LK - sending this command to the GSM-VAC2 PLUS you will get back the SMS with all

    currently programmed links (LK0 LK5).

    ;PRIP;

    Print IP - sending this command to the GSM-VAC2 PLUS you will get back the SMS with all

    currently programmed Input parameters (IP0 IP5).

    ;PRIF;

    Print IF - sending this command to the GSM-VAC2 PLUS you will get back the SMS with all

    currently programmed Input filters (IF0 IF5).

    ;PRTO;

    Print TO - sending this command to the GSM-VAC2 PLUS you will get back the SMS with all

    currently programmed telephone numbers which are use for CLIP identification (TO0 TO9).

    ;PRTK;

    Print TK - sending this command to the GSM-VAC2 PLUS you will get back the SMS with allcurrently programmed telephone numbers which are use to enter into programming and remote

    control mode (TK0 TK9).

    ;PROP;

    Print OP- sending this command to the GSM-VAC2 PLUS you will get back the SMS with all

    currently programmed Outputs parameters (OP1 OP4).

    ;PROA;Print OA - sending this command to the GSM-VAC2 PLUS you will get back the SMS with all

    currently programmed Output Alarm links (OA1 OA4).;PRDL;

    Print DL - sending this command to the GSM-VAC2 PLUS you will get back the SMS with all

    currently programmed Delays before dial (DL1 DL4).

    ;PR#;

    Print # - sending this command to the GSM-VAC2 PLUS you will get back the SMS with all

    currently programmed Alarm SMS (#0 - #5)

    ;PRP;Print P - sending this command to the GSM-VAC2 PLUS you will get back the SMS with all

    currently programmed Set-up parameters (RFL, RFT, PTM, RED, CLP)

    CHECKING AND CHANGING THE SYSTEM STATUS;SYS;

    Sending this command to the GSM-VAC2 PLUS you will get back the SMS with state of the

    system. The replay SMS will be:

    ;SYS= ON; System is ON (active inputs)

    ;SYS= OFF; System is OFF (inputs are not active)

    ;SYS=ON;

    Sending this command to the GSM-VAC2 PLUS you will switch the system ON.

    _____________________________________________________________________________

    21

  • 8/7/2019 GSM VAC2 Installers Manual

    22/30

    ;SYS=OFF;

    Sending this command to the GSM-VAC2 PLUS you will switch the system OFF.

    CHECKING THE INPUT STATUS;INP;

    Sending this command to the GSM-VAC2 PLUS you will get the replay SMS with Input status.The replay can be:

    ;INP(1-4)=(OPEN-ON) alarm loop is open and the input is in the alarm state

    ;INP(1-4)=(OPEN-OFF) alarm loop is open and the alarm input is in the idle state

    ;INP(1-4)=(LOW-ON) alarm loop is close on GND and the input is in the alarm state

    ;INP(1-4)=(LOW-OFF) alarm loop is close on the GND and the alarm input is in the idle state

    ;INP(1-4)=(HGH-ON) alarm loop is close on +12VDC and the input is in the alarm state

    ;INP(1-4)=(HIGH-OFF) alarm loop is close on the +12V and the alarm input is in the idle state

    OUTPUTS REMOTE CONTROL BY SMS COMMAND

    ;OUT;

    Sending this command to the GSM-VAC2 PLUS you will get the replay SMS with Output status.The status can be ON or OFF.

    ;OUTX=1;

    Sending this command to the GSM-VAC2 PLUS the output X is going ON.

    ;OUTX=0;

    Sending this command to the GSM-VAC2 PLUS the output X is going OFF.

    X=1,2,3 or 4 for OUT1, OUT2, OUT3 and OUT4

    When you want to get the return message with the Output status you must press + before the

    command. For example:;+OUTX=1;

    The return message will be:

    OUTX=(ON)

    ERASE ALL DATA FROM THE SIM;SIMCLR;

    WARNING!!! Sending this command to the GSM-VAC2 PLUS you will erase all programmed

    data!

    PARAMETERS CHANGING USING THE SMS

    For the fist time programming we suggest to send the; PRALL; command to the GSM-VAC2

    PLUS. On your mobile phone youll get back 12 SMS with all parameters. You can simply re-write

    the parameters and resend the SMS back to GSM-VAC2 PLUS.

    For Example:

    _____________________________________________________________________________

    22

  • 8/7/2019 GSM VAC2 Installers Manual

    23/30

    The first SMS will be SMS with telephone numbers (TK0 TK9). If the SIM card is empty youll

    get following SMS:

    ;TK 0=0;TK1=0;TK2=0;TK3=0;TK 4=0;TK5=0;TK6=0;TK7=0;TK 8=0;TK9=0;

    Youd like to change the TK0 (0770 713 47), TK1 (0774236480) and TK2 (077125563)

    ;TK0=0770 713 47;TK1=077236480;TK2=077125563;TK3=0;TK 4=0;TK5=0;TK6=0;TK7=0;TK8=0;TK9=0;

    If you put the + before SMS string than youll automatically get the return message with just

    programming values.

    Example:

    SMS to GSM-VAC2+:

    ;+TK0=0770 713 47;TK1=0772364800;TK2=077125563;TK3=0;TK4=0;TK5=0;TK6=0;TK7=0;TK 8=0;TK9=0;

    Return SMS from GSM-VAC2 PLUS if you use +:

    ;TK0=040 713 470;TK1=077236480;TK2=077125563;TK3=0;TK 4=0;TK5=0;TK6=0;TK7=0;TK

    8=0;TK9=0;

    You can use the same programming procedure for all parameters.

    It is also possible to change just a few different parameters with one SMS. Consider that the SMS

    should not be longer than 160 characters (included space bar).

    For example, you want to change the following parameters and you want to get the confirmation

    SMS back:

    TK1, IP1, IP2, OP3, OP4; IF1, LK1 and RED

    You will create the following SMS:

    ;+TK1=077071347;IP1=1;IP2=1;OP3=15;IF1=120;LK1=1;RED=4;

    Send the SMS to the GSM-VAC2+ telephone number and in a few seconds you will get the replySMS. The sentence of the SMS must be the same as the original you sent to the GSM-VAC2 +.

    Other New Parameters

    _____________________________________________________________________________

    23

  • 8/7/2019 GSM VAC2 Installers Manual

    24/30

    Receive revision of software and quality of signal (PRSQ)

    Command: ;PRSQ;When we send SMS with PRSQ command we receive revision of the device software and signalquality. The signal is momentary, minimal, maximum and average. Form of SMS is like this:

    P4+1.6m(300806)-SQ(5)=30, SQ MIN=21, SQ MAX=30, SQ AVE=25;SQ(5) means momentary signal on VM5 (flashes of blue LED). Value 30 means the strength of

    signal. This value is measured by GSM module. Value of the signal is between 1- 31, where 1means the weakest signal and 31 the strongest signal.

    MGT message replay time

    Is time in seconds, which tells us how long we will hear the voice message during alarm. Default

    value is 20s.

    RGT ring time duration

    Is time in seconds, which tells us how long the ring will last when alarm is on and then skip to call

    the second number or cancel the RING. Default value is 90s.

    C00 conversion 00 to +

    If parameter is set to C00=1 VM5 converts 00 to +. In case that we have on SIM card thefollowing number 0038642364807 and parameter C00=1, VM5 will dial this number

    +38642364807. Parameter is suitable for countries where they dont support calling with starting

    numbers 00. Default value is 0.

    TAM tamper input

    With this parameter we set the desired input to be active even if we reset the inputs. It means that

    the desired input is active for 24h.

    MRES module reset

    Time in hours. Resetting the GSM module is recommended because it is possible that GSM module

    goes in to undefined state. Default time is 168h (one week).

    NEW GSM-VAC2+ FEATURES

    MAIN POWER LOST AND TELEPHONE NUMBERS LINKING LK6, LK7

    The GSM-VAC2+ will send an SMS message in case when the main power is lost (too low or off).

    In this case the unit will send an SMS to user. The default SMS is Main Power Lost and it is

    possible to change it. You can also program how long the unit must be without power. The default

    level is 5 second.The new GSM-VAC2+ can control also the battery level and when the level is under 10, 5 V will

    send the SMS Low Battery.

    _____________________________________________________________________________

    24

  • 8/7/2019 GSM VAC2 Installers Manual

    25/30

    The low level of the battery can be detected in cases where the unit works without main powersupply.

    Programming table for MAIN POWER LOST and telephone numbers linking

    GSM-VAC2+ PROGRAMMING TABLE

    SIM CARD PHONE BOOK

    Name

    Number

    (Default) Description

    LK6 Main Power Lost

    LK7 Main Power OK

    Example:

    GSM-VAC2+ PROGRAMMING TABLE

    SIM CARD PHONE BOOK

    NameNumber(Default)

    Description

    LK6 01 Main Power Lost SMS will be send to TL0 and TL1LK7 02 Main Power OK SMS will be send to TL0 and TL2LK remote programming by SMS

    For the upper example send the following SMS from the host phone to the GSM-VAC2+:

    ;LK6=01;LK7=02;If you want to get the confirmation SMS back then write + before SMS command:

    ;+ LK6=01;LK7=02;

    LOW BATTERY AND TELEPHONE NUMBERS LINKING LK7, LK8Programming table for LOW BATTERY and telephone numbers linking

    GSM-VAC2+ PROGRAMMING TABLE

    SIM CARD PHONE BOOK

    NameNumber

    (Default)Description

    LK8 Low Battery (less then 10,5V)

    LK9 Low Battery OK (under 10,5V)

    Example:

    GSM-VAC2+ PROGRAMMING TABLE

    SIM CARD PHONE BOOK

    NameNumber

    (Default)Description

    LK8 01 Low Battery SMS will be send to TL0 and TL1

    LK9 02 Low Battery OK SMS will be send to TL0 and TL2LK6 and LK7 remote programming by SMS

    For the upper example send the following SMS from the host phone to the GSM-VAC2+:

    ;LK6=01;LK7=02;If you want to get the confirmation SMS back then write + before SMS command:

    ;+ LK6=01;LK7=02;

    _____________________________________________________________________________

    25

  • 8/7/2019 GSM VAC2 Installers Manual

    26/30

    MAIN POWER LOST FILTER PARAMETR - VMTParameter VMT determines the length of the pulse which is required to create the alarm after the

    main power is lost. This time can be from 1 second up to 240 seconds. The default value is 5

    seconds.

    For example: When the GSM-VAC2+ is without main power supply more than 5 seconds (default)

    then will send the SMS message with following text: Main Power Lost.

    At the moment when the main power comes back the GSM-VAC2+ will send the SMS messagewith following text: Main Power OK.

    Programming table for MAIN POWER LOST filter VMT

    GSM-VAC2+ PROGRAMMING TABLE

    SIM CARD PHONE BOOK

    NameNumber

    (Default) Description

    VMT 5 Main Power Lost filter (5 seconds default)MAIN POWER LOST filter remote programming by SMS

    For the upper example send the following SMS from the host phone to the GSM-VAC2+:

    ;VMT=5;If you want to get the confirmation SMS back then write + before SMS command:

    ;+VMT=5;LOW BATTERY FILTER PARAMETR - VBT

    Parameter VBT determinate length of the pulse which is required to create the alarm after the power

    of the battery is low and it is below 10,5V. This time can be from 1 second up to 240 seconds. The

    default value is 10 seconds.

    NOTE:The Low battery will be detected when the GSM-VAC2+ operates only with back-up battery

    and it is not connected on the Main Power Supply.

    For example: When the voltage of the back up battery is less then 10,5V, the GSM-VAC2+ will

    send the SMS message with the following text: Low Battery.

    At the moment when the battery power will be higher then 10,5V the GSM-VAC2+ will send the

    SMS message with the following text: Low Battery OK.Programming table for LOW BATTERY filter - VBT

    GSM-VAC2+ PROGRAMMING TABLE

    SIM CARD PHONE BOOK

    NameNumber

    (Default)Description

    VBT 10 Low Battery filter (10 seconds default)LOW BATTERY filter remote programming by SMS

    For the upper example send the following SMS from the host phone to the GSM-VAC2+:

    ;VBT=10;

    If you want to get the confirmation SMS back then write + before SMS command:

    _____________________________________________________________________________

    26

  • 8/7/2019 GSM VAC2 Installers Manual

    27/30

    ;+VBT=10;MAIN POWER LOST and LOW BATTERY text editor

    In case of Main Power Lost or Low Battery event you can send also short SMS message to the

    client. It is possible to use default pre-programming SMS messages or you can write your own text

    (different languages).Programming table for MAIN POWER LOST and LOW BATTERY text messages

    PHONE BOOK NAME DEFAULT MESSAGES

    1 2 3 4 5 6 7 8 9 10 11 12 13 14# 6 M A I N P O W R L O S T# 7 M A I N P O W R O K# 8 B A T T E R Y L O W# 9 B A T T E R Y O K

    Normally, when we want to store the SMS text, the telephone number needs to beentered. Sincethe latter is required only because of the basic design of the phone book memory, it is not important

    what number we enter.

    When we enter the number which is not equal to 0 this number will be pasted together with text

    message.MAIN POWER LOST and LOW BATTERY text messages remote programming by SMS

    For the upper example send the following SMS from the host phone to the GSM-VAC2+:

    ;#6MAIN POWER LOST=0; #7MAIN POWER OK=0; BATTERY LOW =0;BATTERYOK=0;If you want to get the confirmation SMS back then write + before SMS command:

    ;+#6MAIN POWER LOST=0; #7MAIN POWER OK=0; BATTERY LOW =0;BATTERYOK=0;INPUT TRIGGER COUNTER BEFORE ALARM - IC

    With IC parameter you can program how many triggers on the input there must be for the alarm

    activation. The counter can be programmed from 1 to 240 pulses. The default value is 0 and thismean immediate alarm.Programming table for the input trigger counter - IC

    GSM-VAC2+ PROGRAMMING TABLE

    SIM CARD PHONE BOOK

    NameNumber

    (Default)Description

    IC1 0 Default value is 0 immediate alarm on Input 1

    IC2 0 Default value is 0 immediate alarm on Input 2

    IC3 0 Default value is 0 immediate alarm on Input 3

    IC4 0 Default value is 0 immediate alarm on Input 4

    Example:

    GSM-VAC2+ PROGRAMMING TABLE

    SIM CARD PHONE BOOK

    NAME NUMBER DESCRIPTION

    IC1 3 2 triggers on Input 1 for alarm

    IC2 5 5 triggers on Input 2 for alarm

    IC3 0 Immediate alarm on Input 3

    IC4 4 4 triggers on Input 4 for alarm

    The input trigger counter before alarm remote programming by SMS

    For the above example send the following SMS from the host phone to the GSM-VAC2+

    _____________________________________________________________________________

    27

  • 8/7/2019 GSM VAC2 Installers Manual

    28/30

    ;IC1=3;IC2=5;IC3=0;IC4=4;If you want to get the confirmation SMS back then write + before SMS command:

    ;+IC1=3;IC2=5;IC3=0;IC4=4;INPUT TRIGGER COUNT UP INACTIVITY PRESET IR

    The IR parameter determines the time before the pulse counter (ICn parameter) will be reset on 0.

    The IRn value can be in second, hours and days.For example:

    1 - 60 in second (1 = 1s, 60 = 60s)

    61 120 in minutes (61 = 1min., 120 = 60min.)

    121 - 150 in hours (121 = 1h, 150 = 30h)

    151 250 in days (151 = 1 day, 250 = 100 days)

    Programming table for the input trigger count up inactivity preset - IR

    GSM-VAC2+ PROGRAMMING TABLE

    SIM CARD PHONE BOOK

    NameNumber

    (Default)Description

    IR1 0 Default value is 0 no counter preset

    IR2 0 Default value is 0 no counter preset

    IR3 0 Default value is 0 no counter preset

    IR4 0 Default value is 0 no counter preset

    Example:

    GSM-VAC2+ PROGRAMMING TABLE

    SIM CARD PHONE BOOK

    NAME NUMBER DESCRIPTION

    IR1 20 Counter preset time is 20 seconds

    IR2 75 Counter preset time is 15 minutes

    IR3 131 Counter preset time is 10 hours

    IR4 157 Counter preset time is 7 days

    The input trigger count up inactivity preset remote programming by SMS

    For the above example send the following SMS from the host phone to the GSM-VAC2+:

    ;IR1=20;IR2=75;IR3=131;IR4=157;If you want to get the confirmation SMS back then write + before SMS command:

    ;+IR1=20;IR2=75;IR3=131;IR4=157;ACTIV ALARM SMS MESSAGE RE-SEND TIME - IA

    The GSM-VAC2+ can resend the alarm SMS message when the Input is still in the alarm condition.This time is programmed by IA parameter and it can be in minutes, hours or days.

    For example:1 - 60 in second (1 = 1s, 60 = 60s)

    61 120 in minutes (61 = 1min., 120 = 60min.)

    121 - 150 in hours (121 = 1h, 150 = 30h)

    151 250 in days (151 = 1 day, 250 = 100 days)

    _____________________________________________________________________________

    28

  • 8/7/2019 GSM VAC2 Installers Manual

    29/30

    Programming table for the active alarm re-send time - IA

    GSM-VAC2+ PROGRAMMING TABLE

    SIM CARD PHONE BOOK

    NameNumber(Default)

    Description

    IA1 0 Default value is 0 the re-send time is not activeIA2 0 Default value is 0 the re-send time is not active

    IA3 0 Default value is 0 the re-send time is not active

    IA4 0 Default value is 0 the re-send time is not active

    Example:

    GSM-VAC2+ PROGRAMMING TABLE

    SIM CARD PHONE BOOK

    NameNumber(Default)

    Description

    IA1 20 SMS will be re-send after 20s of the Input activity

    IA2 75 SMS will be re-send after 15min of the Input activity

    IA3 131 SMS will be re-send after 10h of the Input activity

    IA4 157 SMS will be re-send after 7 days of the Input activity

    The active alarm re-send time remote programming by SMS

    For the above example send the following SMS from the host phone to the GSM-VAC2+:

    ;IA1=20;IA2=75;IA3=131;IA4=157;If you want to get the confirmation SMS back then write + before SMS command:

    ;+IA1=20;IA2=75;IA3=131;IA4=157;

    Check credit for a PRE-PAYSIM CARD

    V1 Command

    Command ;PRV1;Sending this command to the GSM-VAC2+ you will get back the SMS with Credit amount on yourPre-pay SIM card

    V1=*#1345# for Vodafone

    V1=*#10# for O2

    V1=*#check code with tmobile# for T MOBILEOrange only have a voice system so this feature is not available.

    Send text ;PRV1;

    Remaining credit will be received on your phone.

    _____________________________________________________________________________

    29

  • 8/7/2019 GSM VAC2 Installers Manual

    30/30

    Edgarsson Security DesignsCilymaenllwyd House

    LoginWhitland

    SA34 0XA

    Tel. 01437 563900

    Fax. 0870 122 0613

    Email [email protected]

    Web pages at

    www.edgarsson.co.uk