Upload
trish
View
43
Download
0
Embed Size (px)
DESCRIPTION
GMS provides “One stop solution”. Sacace Biotechnologies Srl “Complete qPCR Solutions”. Founded in 2001. Sacace Biotechnologies s.r.l . , is an innovative Italian company, located in Como, Lombardia. 2001-2009: Caserta, Campania region. Now: Como, Lombardia region. Our Mission. - PowerPoint PPT Presentation
Citation preview
GMS provides “One stop solution”Sacace Biotechnologies Srl
“Complete qPCR Solutions”
2
Founded in 2001 Sacace Biotechnologies s.r.l., is an innovative Italian
company, located in Como, Lombardia
2001-2009: Caserta, Campania region Now: Como, Lombardia region
3
Our MissionTo supply the best products to the
international diagnostics and pharmaceutical industry, as well as to hospitals and laboratories
through a global network of distributors located in more than 60 countries all over the world.
Sacace Worldwide
5
Functions• Research & Development• Manufacturing• Logistics• Marketing• Certifications (ISO 9001:2008
13485:2012, CE Mark - Directive 98/79 EC)
• International external quality control
Hepatitis Viruses (Quantitative tests for HCV, HBV, HDV, HGV, HAV detection)
Human Papilloma Viruses (Screening, Typing, Quantitative detection of Low & High Risk genotypes)
STD (Multiplex detection of Chlamydia, Neisseria, Trichomonas, Mycoplasma, Treponema, Candida ….)
Herpes Viruses (Quantitative Multiplex detection of CMV, EBV, HHV6, HSV, VZV)
Our PCR Kits
TORCH infections (Toxoplasma, Rubella, Parvovirus)
Respiratory infections (Tuberculosis, Influenza, hRSV, Bordetella, Pseudomonas, Legionella)
Neurological infections (Enteroviruses, N.meningitidis, H.influenza, Str.pneumoniae)
Gastrointestinal infections (Shigella, Salmonella, E.coli, Rotavirus, Astrovirus, Norovirus, H.pylori)
Our PCR Kits
Single Nucleotide Polymorphisms (SNP):
• Cardio Trombophilia Panel (FII, FV, FVII, FXIII, FGB)
• Cardio Hypertension Panel (ADD, AGT, NOS....)
• Folates Methabolism Panel (MTHFR, MTR, MTRR)
• Haemochromatosis Panel (HFE 187, HFE193,
HFE845)
• Warfarin Panel (CYP2C9, CYP4F2, VKORC1)
Our PCR Kits
Oncologic diseases (Mbcr-ABL, BRCA)Genetically Modified Organisms (Soya,
Corn, Rice, Tomatoes)Veterinary kits (CPV, PPV, CSVF,
BVDV, ASF, Brucella, TGEV...)RNA/DNA extraction kits
Our PCR Kits
Our Real Time PCR kits can work on multiple instruments:
Qiagen Rotorgene TM
Bio-Rad iQ5TM
Cepheid SmartCycler TM
Applied Biosystems 7300/7500/StepOne TM
Stratagene MX3005P TM
Roche LightCycler 2.0 TM
Bioer LineGene-K TM
SaCycler-96 TM from Sacace Biotechnologies ...more to come
Our PCR Kits
SaCycler™-96
SaCycler™-96 Features
4 or 5 channels multiplexing for discrimination of up to five targets in a single reaction well
Strong flexibility thanks to the 96-well format suited for standard PCR microplates, test tubes and strips
Possibility to use tubes with different heights with regulation of the matrix block
Optimal signal/noise ratio and absence of crosstalk ensured by the unique design of the optical track including a separate light source for each channel and a matrix CCD camera
Light emitting diodes (LED) as a light source with a lifetime of about 100,000 hours that does not require maintenance
SaCycler™-96 Features
Wide dynamic range of detection using multiple exposure method, which leads the optimization of signal registration conditions to a whole new level, greatly simplifying or even eliminating the need for fluorescence settings
Main applications are Real-Time quantitation, single nucleotide polymorphisms (SNPs) genotyping, melting curve and gene expression analysis
Instrument comes with the most used Sacace protocols already installed in the software minimizing possibility of error during programming.
SaCycler™-96 Characteristics
Thermal block format 96 test tubes of 0.2 ml (12 х 8) Test tube type 0.2-ml test tubes for PCR (individual, in strips, 8 pieces each or a
holder 12 x 8) Range of thermal block temperature control 0 C…100°С Resolution of temperature setting 0.1°С Absolute accuracy of temperature maintenance ±0.2°С Uniformity of thermal block temperature ±0.15 °С Maximum heating rate of the thermal block within temperature range of 4…99
°С 3.5 °С /s Maximum cooling rate of the thermal block within temperature range of
99….55 °С 2.5°С /s “Hot cover” temperature 105°С 1°С Actuating device of the thermal block Peltier elements Excitation source Light-emitting diode (LED) Detector CCD (charge coupled device) -matrix Number of the fluorescence measurement channels 4 or 5 Excitation/detection wave length 470/525, 532/570, 585/633, 633/670, 690/750
SaCycler™-96 Comparison ABI 7500
BioRad CFX96
Qiagen RotorGene Q SaCycler-96
Thermal System Peltier Peltier air cooled PeltierAverage ramp rate (°C/s) 1.6 3.3 15-20 3.3Temperature accuracy (°C) ±0.25 ±0.2 ±0.25 ±0.2Uniformity of thermal block temperature (°C) ±0.5 ±0.4 ±0.01 ±0.15Range of temperature (°C) 4-100 0-100 ambient-99 0-100
Optical SystemTungsten halogen
lamp LED LED LEDExcitation spectrum 5 filters 450-684 nm 365-680 470-750Detector CCD camera Photodiodes PMT CCD cameraEmission filters/channels 5 6 6 4 or 5
Compatible dyes
FAM, JOE, VIC, NED, TAMRA, Rox, TexasRed,
Cy3, Cy5
FAM, JOE, VIC, NED,
TAMRA, Rox, TexasRed, Cy3, Cy5
FAM, JOE, VIC, NED, TAMRA, Rox, TexasRed,
Cy3, Cy5
FAM, JOE, HEX, R6G, ROX,
TexasRed, Cy5, Cy5.5
Format 96-well plates 96-well plates rotor disk 96-well platesTest tube type (ml) 0.2 0.2 0.1 - 0.2 0.2Supported volumes (µl) 20-100 up to 50 10-50 10-100Weight (Kg) 64 21.4 14 27
Sacace thermalcycling protocols
UROGENITAL + CMV + EBV + TORCH + HPV INFECTIONS
Chlamydia trachomatis Real-TMNeisseria gonorrhoeae Real-TMTreponema pallidum Real-TMMycoplasma genitalium Real-TMUreaplasma parvum, Ureaplasma urealyticum Real-TMMycoplasma hominis Real-TMGardnerella vaginalis Real-TMHSV I,II Real-TMCMV Real-TM QualCMV Real-TM QuantEBV Real-TM QualEBV Real-TM QuantTrichomonas vaginalis Real-TMCandida albicans Real-TMChlamydia trachomatis / Ureaplasma spp. / Mycoplasma genitalium Real-TMChlamydia trachomatis / Ureaplasma spp. / Mycoplasma hominis Real-TMNeisseria gonorrhoeae / Chlamydia trachomatis / Mycoplasma genitalium Real-TMHSV I,II Typing Real-TMUreaplasma parvum / Ureaplasma urealyticum Real-TMTrichomonas vaginalis /Neisseria gonorrhoeae Real-TM
Chlamydia trachomatis / Ureaplasma spp. Real-TMChlamydia trachomatis / Mycoplasma genitalium Real-TMCandida albicans / Candida glabrata / Candida krusei Real-TMHSV / CMV Real-TMMycoplasma hominis / Gardnerella vaginalis Real-TMUreaplasma parvum / Ureaplasma urealyticum / Mycoplasma Real-TMTrichomonas vaginalis / Neisseria gonorrhoeae /Chlamydia trachomatis Real-TMNeisseria gonorrhoeae / Chlamydia trachomatis Real-TMPseudomonas aeruginos Real-TMPneumocystis jirovecii Real-TMCMV/EBV/HHV6 QuantHHV6 Real-TM QuantRubella Real-TMToxoplasma Real-TMParvovirus B19 Real-TM QuantHPV High Risk Screening Real-TM QuantHPV High Risk Typing Real-TMHPV 6/11 Real-TMHPV 16/18 Real-TM
38 different kits
Sacace thermalcycling protocols
NEUROLOGICALPoliovirus Real-TMNHS Meningitidis (N. meningitidis, H. influenzae, Str. pneumoniae) Real-TM
INTESTINAL INFECTIONSNorovirus/Astrovirus/Rotavirus Real-TMShigella/Salmonella/Campylobacter Real-TMEHEC Real-TM
Helicobacter pylori Real-TM
RESPIRATORY INFECTIONSInfluenza A/B Real-TMInfluenza A Real-TMInfluenza A H5N1 Real-TMInfluenza A H1N1 Real-TMInfluenza A H1N1/H3N2 Real-TM
Influenza A H5/H7/H9 Real-TMhRSV Real-TM
MTB INFECTIONMTB Real-TMMTB Diff Real-TM
2 different kits
2 different kits
7 different kits
4 different kits
Thanks for your attention