55GGENERAL USE
The 55G lends itself to a wide variety of uses in the communications field, particularly where unusual wind loading and height requirements exist. The 55G was designed to provide excel-lent strength in heights up to 400’. When properly installed, the standard tower will support loads as shown on various guyed and self-supporting information sheets in the ROHN catalog.
FEATURES• Completely hot-dip galvanized after fabrication • Heavy steel tube or solid steel rod side rails• Built on 17” equilateral triangle design• Utilizes high strength steel tubing side rails• Zig-Zag® cross bracing is formed from a con- tinuous 7/16” solid steel rod electrically welded every 16 1/4” on the side rails• Each 10’ section is joined to the other and double bolted at each leg joint for extra strength
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
G G U Y E D T O W E R S - 5 5 G
S T A N D A R D 5 5 G G U Y E D T O W E R
92© 2010 ROHN PRODUCTS LLC
The first. The original.ROHN 55G
CAUTION: the mixing of so-called interchangeable copies of ROHN towers with ROHN towers is dangerous and voids all engineering or warranty data supplied by ROHN. Materials used by the so-called copies are not the same quality and have not been tested or engineered by ROHN to conform to the same quality standards. Mixing of
ROHN items may endanger the lives of your customers and cause serious tower failures and financial misfortune for all concerned.
* Per Rev. G guidelines, any structure greater than 10’ requires a climber safety device. Please see page 108 for ordering information.
REV. G
includes
REV. F &
10’ - 0”
18 1/2“
1.50” O.D.(11 GA. wall)
STANDARD SECTION55G - 10’ Section
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
GG U Y E D T O W E R S - 5 5 G
S T A N D A R D 5 5 G G U Y E D T O W E RS E C T I O N S
93
9 13/16”
7/16” Dia. bar
© 2010 ROHN PRODUCTS LLC
17”PARTS & ACCESSORIES PAGES 107-108GROUNDING INFORMATION PAGE 109-110FOUNDATION INFORMATION PAGES 111-112
QUICK REFERENCE14 3/4”
CONCRETE BASE PLATEBPC55G*
FOR USE WITH PIER PIN EMBEDDED IN CONCRETE.
PIER PIN3/4x12PP
MUST BE ORDERED SEPARATELY.
BEACON PLATEAPL55G
FOR MOUNTING BEACON. BEACONPLATE BOLTS TO THE TOP OF
A STANDARD SECTION.
EPA (SQ. FT.) For Exposure B, Revision G
EPA (SQ. FT.) For Exposure C, Revision G
EPA (SQ. FT.), Revision F
P/N 55G90R100
117’
90’
85’
42’
80’
3/16” EHS(399#)
30.4
32.0
39.0
P/N 55G90R100 Tower Model
Windspeed (Rev. G) ROHN TowerTower Height
EPA= Effective Projected Area
Tower and foundation installations should be performed by qualified and experienced personnel using construction drawings. This document is to serve as a guide for sizing and buying the 55G tower.
All types of antenna installations should be thoroughly inspected by qualified personnel and re-marked with appropriatedanger and anti-climb labels at least twice a year to ensure safety and proper performance.
DESIGN NOTES:
1. Tower designs are in accordance with ANSI/TIA-222-F-1996 and ANSI/TIA-222-G-2005, Class I Structures. 2. Design assumes towers are installed on level ground. Lower EPA values will apply for roof mounted towers or for sites located on unusual terrain. 3. Designs assume two 7/8” diameter lines on each tower face. 4. Anchor radius is from tower base to intersection of anchor rod with ground. 5. Tower designs and guy chord lengths shown are based on level ground. Initial tensions for guys in pounds at 60º Fahrenheit are shown in ( ). 6. Antenna and mounts are assumed symmetrically placed at the tower top.
PARTS LIST NOTES:
1. Items listed are required for complete (ground) guyed towers. Base and anchor details will be required for installation on roofs or for sites located on unusual terrains and wind loading criteria, for all roof type installations. 2. Standard guys provided with each standard tower include an additional 6% length. 3. Anchor grounding (AGK1GGX) and base grounding (BGK3GGX) are included with the tower material. 4. Installation information and a safety package (P/N: ACWS) are included with each tower.
FOR FOUNDATION INFORMATION, PLEASE SEE PAGES 111-112.
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
G G U Y E D T O W E R S - 5 5 G
S T A N D A R D D E S I G N - 5 5 G9 0 M P H R E V . G , 7 0 M P H R E V . F
94© 2010 ROHN PRODUCTS LLC
1/4” EHS(665#)
S T A N D A R D D E S I G N - 5 5 G9 0 M P H R E V . G , 7 0 M P H R E V . F
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
GG U Y E D T O W E R S - 5 5 G
95© 2010 ROHN PRODUCTS LLC
P/N: 55G90R120
120’ TOWER
105’37.0 29.3OR
142’
96’
3/16” EHS(399#)
122’75’
35’ 102’
1/4” EHS(665#)
P/N: 55G90R100
100’ TOWER
85’39.0 30.4OR
117’
80’
1/4” EHS(665#)
90’42’
3/16” EHS(399#)
P/N: 55G90R110
110’ TOWER
95’37.9 29.8OR
129’
88’
1/4” EHS(665#)
100’47’
3/16” EHS(399#)
P/N: 55G90R130
130’ TOWER
115’36.1 28.7OR
155’
104’
3/16” EHS(399#)
129’76’
38’ 111’
1/4” EHS(665#)
P/N: 55G90R140
140’ TOWER
125’35.4 28.3OR
168’
112’
3/16” EHS(399#)
139’83’
41’ 119’
1/4” EHS(665#)
TOWER PARTSINCLUDED
GUY WIRE &CONNECTION
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
GAC3455TOP AGK1GGX BGK2GGX
10 1 1 2
300’ 375’ 6 6 6
3 1 3
100’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G90R100
FDNSBASE ANCHOR
3/8THH
6 6
1/2TBE&J
TOWER PARTSINCLUDED
GUY WIRE &CONNECTION
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
AGK1GGX BGK2GGX
11 1 1 2
325’ 425’ 6 6 6
3 1 3
110’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G90R110
FDNSBASE ANCHOR
3/8THH
6 6
1/2TBE&J
TOWER PARTSINCLUDED
GUY WIRE &CONNECTION
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
AGK1GGX BGK2GGX
12 1 1 3
725’ 475’ 12 6 12
3 1 3
120’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G90R120
FDNSBASE ANCHOR
3/8THH
6 9
1/2TBE&J
TOWER PARTSINCLUDED
GUY WIRE &CONNECTION
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
AGK1GGX BGK2GGX
13 1 1 3
775’ 500’ 12 6 12
3 1 3
130’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G90R130
FDNSBASE ANCHOR
3/8THH
6 9
1/2TBE&J
TOWER PARTSINCLUDED
GUY WIRE &CONNECTION
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
AGK1GGX BGK2GGX
14 1 1 3
825’ 550’ 12 6 12
3 1 3
140’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G90R140
FDNSBASE ANCHOR
3/8THH
6 9
1/2TBE&J
CPC.5/.75
3
TBSAFETY
3
CPC.5/.75
3
TBSAFETY
3
TBSAFETY
3
CPC.5/.75
3
TBSAFETY
3
CPC.5/.75
3
TBSAFETY
3
CPC.5/.75
3
CB1G AB2
CB1G AB2
CB1G AB2
CB1G AB2
CB1G AB2
32.0
31.2
30.4
29.8
29.0
GAC3455TOP
GAC3455TOP
GAC3455TOP
GAC3455TOP
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
G G U Y E D T O W E R S - 5 5 G
S T A N D A R D D E S I G N - 5 5 G9 0 M P H R E V . G , 7 0 M P H R E V . F
96© 2010 ROHN PRODUCTS LLC
P/N: 55G90R150
150’ TOWER
135’34.7 27.9OR
180’
120’
3/16” EHS(399#)
151’92’
45’ 128’
1/4” EHS(665#)
P/N: 55G90R160
160’ TOWER
145’33.9 27.5OR
193’
128’
3/16” EHS(399#)
160’96’
48’ 137’
1/4” EHS(665#)
P/N: 55G90R170
170’ TOWER
155’33.3 27.2OR
206’
136’
178’115’
37’ 141’
75’155’ 3/16” EHS
(399#)
1/4” EHS(665#)
P/N: 55G90R180
180’ TOWER
165’32.8 26.8OR
219’
144’
190’124’
42’ 150’
83’166’ 3/16” EHS
(399#)
1/4” EHS(665#)
P/N: 55G90R190
190’ TOWER
175’32.4 26.5OR
232’
152’
201’131’
43’ 158’
87’175’ 3/16” EHS
(399#)
5/16” EHS(1,120#)
TOWER PARTSINCLUDED
GUY WIRE &CONNECTION
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
AGK1GGX BGK2GGX
15 1 1 3
900’ 600’ 12 6 12
3 1 3
150’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G90R150
FDNSBASE ANCHOR
3/8THH
6 6
1/2TBE&J
TOWER PARTSINCLUDED
GUY WIRE &CONNECTION
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
AGK1GGX BGK2GGX
16 1 1 3
950’ 625’ 12 6 12
3 1 3
160’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G90R160
FDNSBASE ANCHOR
3/8THH
6 9
1/2TBE&J
TOWER PARTSINCLUDED
GUY WIRE &CONNECTION
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
GAC3455TOP AGK1GGX BGK2GGX
17 1 1 4
1525’ 675’ 18 6 18
3 1 3
170’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G90R170
FDNSBASE ANCHOR
3/8THH
6 12
1/2TBE&J
TOWER PARTSINCLUDED
GUY WIRE &CONNECTION
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
GAC3455TOP AGK1GGX BGK2GGX
18 1 1 4
1625’ 700’ 18 6 18
3 1 3
180’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G90R180
FDNSBASE ANCHOR
3/8THH
6 12
1/2TBE&J
TOWER PARTSINCLUDED
GUY WIRE &CONNECTION
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
3/16EHS142265 BG2142 BG2146 5/16THH
GAC5655TOP AGK1GGX BGK2GGX
19 1 1 4
1700’ 750’ 18 6 18
3 1 3
190’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G90R190
FDNSBASE ANCHOR
7/16THH
6 12
5/8TBE&J
CPC.5/.75
3
TBSAFETY
3
CPC.5/.75
3
TBSAFETY
3
CPC.5/.75
3
TBSAFETY
3
CPC.5/.75
3
TBSAFETY
3
CPC.5/.75
3
TBSAFETY
3
CB2G AB2
CB2G AB2
CB2G AB2
CB2G AB2
CB2G AB3
28.6
28.0
27.4
27.0
26.6
GAC3455TOP
GAC3455TOP
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
GG U Y E D T O W E R S - 5 5 G
S T A N D A R D D E S I G N - 5 5 G9 0 M P H R E V . G , 7 0 M P H R E V . F
97© 2010 ROHN PRODUCTS LLC
P/N: 55G90R200
200’ TOWER
185’31.9 26.2OR
244’
160’
212’139’
47’ 167’
93’185’ 3/16” EHS
(399#)
TOWER PARTSINCLUDED
GUY WIRE &CONNECTION
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
3/16EHS 142265 BG2142 BG2146 5/16THH
GAC5655TOP AGK1GGX BGK2GGX
20 1 1 4
1800’ 800’ 18 6 18
3 1 3
200’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G90R200
FDNSBASE ANCHOR
7/16THH
6 12
5/8TBE&J
TOWER PARTSINCLUDED
GUY WIRE &CONNECTION
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
3/16EHS 142265 BG2142 BG2146 5/16THH
GAC5755TOP AGK1GGX BGK2GGX
22 1 1 5
2650’ 875’ 24 6 24
3 1 3
220’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G90R220
FDNSBASE ANCHOR
7/16THH
6 15
3/4TBE&J
P/N: 55G90R220
220’ TOWER
205’31.1 25.7OR
270’
176’
241’
164’
41’
123’215’
3/16” EHS(399#)
194’
180’
82’5/16” EHS(1,120#)
TOWER PARTSINCLUDED
GUY WIRE &CONNECTION
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
3/16EHS 142265 BG2142 BG2146 5/16THH
AGK1GGX BGK2GGX
24 1 1 5
2900’ 950’ 24 6 24
3 1 3
240’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G90R240
FDNSBASE ANCHOR
7/16THH
6 12
1/2TBE&J
P/N: 55G90R240
240’ TOWER
225’30.3 25.3OR
296’
192’
265’
182’
45’
135’235’
3/16” EHS(399#)
213’
197’
92’
5/16” EHS(1,120#)
CPC1.5/2
3
TBSAFETY
3
CPC1.5/2
3
TBSAFETY
3
CPC1/1.25
3
TBSAFETY
3
260’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G90R260
P/N: 55G90R260
260’ TOWER
245’29.6 24.8OR
321’
208’
5/16” EHS(1,120#)
202’
42’
162’
122’
77’104’
3/16” EHS(399#)
64’
82’241’
264’
290’
TOWER PARTSINCLUDED
GUY WIRE &CONNECTION
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
GAC5655TOP BGK2GGX
CPC.5/.75
26 1 1 6
3
3 3
3/16EHS
3125’
7/16THH
6
142265
1025’
BG2142
30
1/2TBE&J
6
BG2146
6
5/8TBE&J
12
5/16THH
30
CPC1/1.25
3
AGK1GGX
23
CB2G AB3
CB2G AB3
CB3G AB3
BASE INNERANCHOR
CB3G
OUTERANCHOR
AB3AB2
24.2
23.4
25.3
22.2
5/16” EHS(1,120#)
GAC5755TOP
GAC3455TOP TBSAFETY
6
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
G G U Y E D T O W E R S - 5 5 G
S T A N D A R D D E S I G N - 5 5 G9 0 M P H R E V . G , 7 0 M P H R E V . F
98© 2010 ROHN PRODUCTS LLC
280’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G90R280
P/N: 55G90R280
280’ TOWER
265’29.0 24.4OR
347’
224’
5/16” EHS(1,120#)
222’
43’
175’
132’
82’110’
3/16” EHS(399#)
70’
85’260’
284’
315’
300’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G90R300
P/N: 55G90R300
300’ TOWER
285’28.4 24.1OR
373’
240’
5/16” EHS(1,120#)
242’
42’
202’162’ 3/16” EHS
(399#)
100’
82’
290’
314’
341’
108’129’158’
122’
320’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G90R320
P/N: 55G90R320
320’ TOWER
305’27.9 23.8OR
398’
256’
5/16” EHS(1,120#)
262’
42’
215’172’ 3/16” EHS
(399#)
100’
82’
308’
334’
366’
108’129’160’
125’
340’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G90R340
P/N: 55G90R340
340’ TOWER
325’27.4 23.5OR
424’
272’
5/16” EHS(1,120#)
282’
42’
202’162’ 3/16” EHS
(399#)
96’
82’
317’
364’
105’126’155’
122’
339’
392’242’
21.8
21.2
20.8
20.4
TOWER PARTSINCLUDED
GUY WIRE &CONNECTION
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
GAC5655TOP BGK2GGX
CPC.5/.75
28 1 1 6
3
3 3
3/16EHS
3350
7/16THH
6
142265
1125’
BG2142
30
1/2TBE&J
6
BG2146
6
5/8TBE&J
12
5/16THH
30
CPC1/1.25
3
AGK1GGX
23
BASE INNERANCHOR
CB4G
OUTERANCHOR
AB3AB2
TOWER PARTSINCLUDED
GUY WIRE &CONNECTION
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
CPC.5/.75
30 1 1 7
3
3 3
3/16EHS
4275’
7/16THH
6
142265
1200’
BG2142
36
1/2TBE&J
9
BG2146
6
5/8TBE&J
12
5/16THH
36
TBSAFETY
6
AGK1GGX
23
BASE INNERANCHOR
CB4G
OUTERANCHOR
AB3AB2
TOWER PARTSINCLUDED
GUY WIRE &CONNECTION
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX CPC.5/.75
32 1 1 7
33 3
3/16EHS
2250’
7/16THH
6
1/4EHS
2250’
BG2142
24
1/2TBE&J
9
BG2146
6
5/8TBE&J
12
BG2144
12
TBSAFETY
6
AGK1GGX
23
BASE INNERANCHOR
CB4G
OUTERANCHOR
AB3AB2
TOWER PARTSINCLUDED
GUY WIRE &CONNECTION
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX CPC.5/.75
34 1 1 8
33 3
3/16EHS
5725’
7/16THH
6
142265
1350’
BG2142
30
1/2TBE&J
12
BG2146
6
5/8TBE&J
3
5/16THH
30
TBSAFETY
6
AGK1GGX
23
BASE INNERANCHOR
CB4G
OUTERANCHOR
AB3AB2
142265
1275’1/4” EHS(665#)
1/4” EHS(665#)
1/4EHS
5725’
GAC3455TOP
GAC5655TOPGAC3455TOP
GAC5655TOPGAC3455TOP
GAC5655TOPGAC3455TOP
TBSAFETY
6
CPC1/1.25
3
3/8THH
12
5/16THH
24
CPC1/1.25
3
CPC1/1.25
3
3/8THH
12
BG2144
12
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
GG U Y E D T O W E R S - 5 5 G
S T A N D A R D D E S I G N - 5 5 G9 0 M P H R E V . G , 7 0 M P H R E V . F
99© 2010 ROHN PRODUCTS LLC
360’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G90R360
P/N: 55G90R360
360’ TOWER
345’27.0 23.2OR
449’
288’
5/16” EHS(1,120#)
302’
42’
212’168’ 3/16” EHS
(399#)
100’
84’
333’
385’
108’131’161’
126’
358’
417’255’
1/4” EHS(665#)
380’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G90R380
P/N: 55G90R380
380’ TOWER
365’26.6 22.9OR
475’
304’
5/16” EHS(1,120#)
319’
45’
227’181’ 3/16” EHS
(399#)
110’
92’
353’
409’
119’143’174’
135’
354’
441’273’
1/4” EHS(665#)
P/N: 55G90R400
400’ TOWER
385’13.2 22.7OR
501’
320’
5/16” EHS(1,120#)
335’
46’
235’185’ 3/16” EHS
(399#)
120’
92’
370’
429’
128’151’183’
138’
397’
463’285’
1/4” EHS(665#)
20.0
19.6
19.2
TOWER PARTSINCLUDED
GUY WIRE &CONNECTION
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX CPC.5/.75
36 1 1 8
33 3
3/16EHS
3475’
5/16THH
30
1/4EHS
2575’
3/8THH
12
142265
1450’
7/16THH
6
BG2142
30
BG2144
12
1/2TBE&J
9
AGK1GGX
23
APL1258UM
1
BG2146
6
5/8TBE&J
15
BASE INNERANCHOR
CB5G
OUTERANCHOR
AB4AB2
TOWER PARTSINCLUDED
GUY WIRE &CONNECTION
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX CPC.5/.75
38 1 1 8
33
3/16EHS
3175’
5/16THH
24
1/4EHS
3275’
3/8THH
18
142265
1525’
7/16THH
6
BG2142
24
BG2144
18
15
AGK1GGX
23
APL1258UM
1
BG2146
6
5/8TBE&J
BASE INNERANCHOR
CB5G
OUTERANCHOR
AB4AB2
400’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G90R400
TOWER PARTSINCLUDED
GUY WIRE &CONNECTION
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX CPC.5/.75
40 1 1 8
33
3/16EHS
2075’
5/16THH
18
1/4EHS
4700’
3/8THH
24
142265
1600’
7/16THH
6
BG2142
18
BG2144
24
9
AGK1GGX
2
APL1258UM
1
BG2146
6
1/2TBE&J
BASE INNERANCHOR
CB5G
OUTERANCHOR
AB4AB2
TBSAFETY
6
1/2TBE&J
9
TBSAFETY
6
GAC5655TOPGAC3455TOP
GAC5655TOPGAC3455TOP
3
3
GAC5655TOPGAC3455TOP
3
TBSAFETY
6
15
5/8TBE&J
CPC1/1.25
3
CPC1/1.25
3
CPC1/1.25
3
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
G G U Y E D T O W E R S - 5 5 G
S T A N D A R D D E S I G N - 5 5 G1 1 0 M P H R E V . G , 9 0 M P H R E V . F
100© 2010 ROHN PRODUCTS LLC
P/N: 55G110R120
120’ TOWER
115’24.7 19.6OR
150’
96’
3/16” EHS(399#)
123’77’
38’ 103’
1/4” EHS(665#)
P/N: 55G110R130
130’ TOWER
125’24.2 19.2OR
163’
104’
3/16” EHS(399#)
133’83’
42’ 112’
1/4” EHS(665#)
TOWER PARTSINCLUDED
GUY WIRE &CONNECTION
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
GAC3455TOP AGK1GGX BGK2GGX
10 1 1 3
600’ 400’ 12 6 12
3 1 3
100’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G110R100
FDNSBASE ANCHOR
3/8THH
6 9
1/2TBE&J
3
TBSAFETY
3P/N: 55G110R100
100’ TOWER
95’26.1 20.4OR
124’
80’
3/16” EHS(399#)
102’63’
33’ 86’
1/4” EHS(665#)
P/N: 55G110R110
110’ TOWER
105’25.4 19.9OR
137’
88’
3/16” EHS(399#)
112’70’
35’ 95’
1/4” EHS(665#)
P/N: 55G110R140
140’ TOWER
135’23.6 18.9OR
175’
112’
151’101’
34’ 117’
67’130’ 3/16” EHS
(399#)
1/4” EHS(665#)
TOWER PARTSINCLUDED
GUY WIRE &CONNECTION
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
GAC3455TOP AGK1GGX BGK2GGX
11 1 1 3
675’ 450’ 12 6 12
3 1 3
110’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G110R110
FDNSBASE ANCHOR
3/8THH
6 9
1/2TBE&J
3
TBSAFETY
3
TOWER PARTSINCLUDED
GUY WIRE &CONNECTION
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
GAC3455TOP AGK1GGX BGK2GGX
12 1 1 3
725’ 500’ 12 6 12
3 1 3
120’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G110R120
FDNSBASE ANCHOR
3/8THH
6 9
1/2TBE&J
3
TBSAFETY
3
TOWER PARTSINCLUDED
GUY WIRE &CONNECTION
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
GAC3455TOP AGK1GGX BGK2GGX
13 1 1 3
800’ 525’ 12 6 12
3 1 3
130’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G110R130
FDNSBASE ANCHOR
3/8THH
6 9
1/2TBE&J
3
TBSAFETY
3
TOWER PARTSINCLUDED
GUY WIRE &CONNECTION
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
GAC3455TOP AGK1GGX BGK2GGX
14 1 1 4
1275’ 575’ 18 6 18
3 1 3
140’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G110R140
FDNSBASE ANCHOR
3/8THH
6 12
1/2TBE&J
3
TBSAFETY
3
CB1G AB2
CB1G AB2
CB2G AB2
CB2G AB2
CB2G AB2
19.2
18.6
18.2
17.8
17.2
CPC.5/.75
CPC.5/.75
CPC.5/.75
CPC.5/.75
CPC.5/.75
S T A N D A R D D E S I G N - 5 5 G1 1 0 M P H R E V . G , 9 0 M P H R E V . F
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
GG U Y E D T O W E R S - 5 5 G
101© 2010 ROHN PRODUCTS LLC
P/N: 55G110R150
150’ TOWER
145’23.2 18.7OR
188’
120’
161’108’
36’ 125’
72’140’ 3/16” EHS
(399#)
1/4” EHS(665#)
TOWER PARTSINCLUDED
GUY WIRE &CONNECTION
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
GAC5655TOP AGK1GGX BGK2GGX
15 1 1 4
1375’ 600’ 18 6 18
3 1 3
150’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G110R150
FDNSBASE ANCHOR
3/8THH
6 12
5/8TBE&J
3
TBSAFETY
3
P/N: 55G110R180
180’ TOWER
175’22.0 18.0OR
227’
144’
201’
140’
35’
105’178’
3/16” EHS(399#)
160’
148’
70’
1/4” EHS(665#)
P/N: 55G110R160
160’ TOWER
155’22.8 18.4OR
201’
128’
173’116’
39’ 134’
78’150’ 3/16” EHS
(399#)
5/16” EHS(1,120#)
P/N: 55G110R170
170’ TOWER
165’22.0 18.0OR
214’
136’
184’124’
41’ 142’
83’159’ 3/16” EHS
(399#)
1/4” EHS(665#)
TOWER PARTSINCLUDED
GUY WIRE &CONNECTION
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
GAC5655TOP AGK1GGX BGK2GGX
17 1 1 4
975’ 1275’ 12 12 12
3 1 3
170’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G110R170
FDNSBASE ANCHOR
3/8THH
12 12
5/8TBE&J
3
TBSAFETY
3
P/N: 55G110R190
190’ TOWER
185’21.7 17.8OR
239’
152’
212’
148’
37’
111’188’
3/16” EHS(399#)
169’
156’
74’
5/16” EHS(1,120#)
1/4” EHS(665#)
TOWER PARTSINCLUDED
GUY WIRE &CONNECTION
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
3/16EHS 142265 BG2142 BG2146 5/16THH
GAC5655TOP AGK1GGX BGK2GGX
16 1 1 4
1475’ 650’ 18 6 18
3 1 3
160’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G110R160
FDNSBASE ANCHOR
7/16THH
6 12
5/8TBE&J
3
TBSAFETY
3
TOWER PARTSINCLUDED
GUY WIRE &CONNECTION
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
3/16EHS1/4EHS BG2142 BG2144 5/16THH
GAC5655TOP AGK1GGX BGK2GGX
18 1 1 5
1550’ 1375’ 18 12 18
3 1 3
180’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G110R180
FDNSBASE ANCHOR
3/8THH
12 15
5/8TBE&J
3
TBSAFETY
3
190’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G110R190
TOWER PARTSINCLUDED
GUY WIRE &CONNECTION
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
19 1 1 5
33
FDNSBASE ANCHOR
3/16EHS
1650’
5/16THH
18
1/4EHS
675’
3/8THH
6
142265
775’
7/16THH
6
BG2142
18
5/8TBE&J
15
BG2144
6
AGK1GGX
1
GAC5655TOP
3
BG2146
6
TBSAFETY
3
CB2G AB3
CB2G AB3
CB2G AB3
CB3G AB3
CB3G AB315.6
15.8
16.2
16.4
16.8
CPC1/1.25
CPC1/1.25
CPC1/1.25
CPC1/1.25
CPC1/1.25
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
G G U Y E D T O W E R S - 5 5 G
S T A N D A R D D E S I G N - 5 5 G1 1 0 M P H R E V . G , 9 0 M P H R E V . F
102© 2010 ROHN PRODUCTS LLC
P/N: 55G110R200
200’ TOWER
195’21.4 17.6OR
252’
160’
223’
156’
39’
117’198’
3/16” EHS(399#)
178’
165’
78’
5/16” EHS(1,120#)
1/4” EHS(665#)
200’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G110R200
TOWER PARTSINCLUDED
GUY WIRE &CONNECTION
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
20 1 1 5
33
FDNSBASE ANCHOR
3/16EHS
1750’
5/16THH
18
1/4EHS
725’
3/8THH
6
142265
825’
7/16THH
6
BG2142
18
BG2144
6
AGK1GGX
1
GAC5655TOP
3
BG2146
6
5/8TBE&J
15
TBSAFETY
3
220’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G110R220P/N: 55G110R220
220’ TOWER
215’20.8 17.2OR
278’
176’
5/16” EHS(1,120#)
182’
36’
145’
112’
70’94’
3/16” EHS(399#)
60’
73’209’
228’
253’
1/4” EHS(665#)
TOWER PARTSINCLUDED
GUY WIRE &CONNECTION
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
22 1 1 6
33
3/16EHS
1925’
5/16THH
24
1/4EHS
825’
3/8THH
6
142265
900’
7/16THH
6
BG2142
24
BG2144
6
AGK1GGX
2
GAC5655TOP
3
BG2146
6
1/2TBE&J
6
TBSAFETY
6
5/8TBE&J
12
3
P/N: 55G110R240
240’ TOWER
235’20.3 16.9OR
303’
192’
5/16” EHS(1,120#)
201’
33’
167’133’ 3/16” EHS
(399#)
80’
66’
233’
254’
278’
86’104’127’
99’ 240’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G110R240
TOWER PARTSINCLUDED
GUY WIRE &CONNECTION
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
24 1 1 7
3
3/16EHS
1750’
5/16THH
24
1/4EHS
1700’
3/8THH
12
142265
975’
7/16THH
6
BG2142
24
BG2144
12
AGK1GGX
23
BG2146
6
1/2TBE&J
9
TBSAFETY
6
5/8TBE&J
12
3
P/N: 55G110R260
260’ TOWER
255’19.8 16.6OR
329’
208’
5/16” EHS(1,120#)
219’
38’
183’147’ 3/16” EHS
(399#)
88’
75’
255’
277’
302’
96’115’142’
111’
1/4” EHS(665#)
1/4” EHS(665#)
260’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G110R260
TOWER PARTSINCLUDED
GUY WIRE &CONNECTION
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
26 1 1 7
33
3/16EHS
1500’
5/16THH
18
1/4EHS
2300’
3/8THH
18
142265
1050’
7/16THH
6
BG2142
18
BG2144
18
AGK1GGX
23
BG2146
6
1/2TBE&J
9
TBSAFETY
6
5/8TBE&J
12
3
CB3G AB313.2
12.8
12.4
12.0
BASE INNERANCHOR
CB4G
OUTERANCHOR
AB3AB2
BASE INNERANCHOR
CB4G
OUTERANCHOR
AB3AB2
BASE INNERANCHOR
CB5G
OUTERANCHOR
AB3AB2
CPC1/1.25
CPC.5/.75
CPC.5/.75
CPC.5/.75
GAC3455TOP
GAC5655TOPGAC3455TOP
GAC5655TOPGAC3455TOP
3
CPC1/1.25
3
CPC1/1.25
3
3
CPC1/1.25
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
GG U Y E D T O W E R S - 5 5 G
S T A N D A R D D E S I G N - 5 5 G1 1 0 M P H R E V . G , 9 0 M P H R E V . F
103© 2010 ROHN PRODUCTS LLC
P/N: 55G110R280
280’ TOWER
275’19.4 16.4OR
355’
224’
5/16” EHS(1,120#)
241’
35’
173’139’ 3/16” EHS
(399#)
84’
71’
264’
305’
91’110’134’
105’
283’
329’207’
1/4” EHS(665#)
280’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G110R280
TOWER PARTSINCLUDED
GUY WIRE &CONNECTION
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
28 1 1 8
33
3/16EHS
2825’
5/16THH
30
1/4EHS
2025’
3/8THH
12
142265
1150’
7/16THH
6
BG2142
30
1/2TBE&J
9
BG2144
12
AGK1GGX
23
BG2146
6
TBSAFETY
6
5/8TBE&J
15
3
P/N: 55G110R300
300’ TOWER
295’19.0 16.1OR
380’
240’
5/16” EHS(1,120#)
259’
41’
187’151’ 3/16” EHS
(399#)
100’
79’
283’
328’
108’127’152’
115’
304’
353’223’
1/4” EHS(665#)
300’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G110R300
TOWER PARTSINCLUDED
GUY WIRE &CONNECTION
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
30 1 1 8
33
3/16EHS
1675’
5/16THH
18
1/4EHS
2500’
3/8THH
18
142265
2350’
7/16THH
12
BG2142
18
1/2TBE&J
9
BG2144
18
AGK1GGX
23
BG2146
12
TBSAFETY
6
5/8TBE&J
15
3
11.6
BASE INNERANCHOR
CB5G
OUTERANCHOR
AB4AB2
BASE INNERANCHOR
CB5G
OUTERANCHOR
AB4AB211.2
CPC.5/.75
CPC.5/.75
GAC5655TOPGAC3455TOP
GAC5655TOPGAC3455TOP
3
CPC1/1.25
3
CPC1/1.25
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
G G U Y E D T O W E R S - 5 5 G
S T A N D A R D D E S I G N - 5 5 G1 3 0 M P H R E V . G , 1 1 0 M P H R E V . F
104© 2010 ROHN PRODUCTS LLC
P/N: 55G130R100
100’ TOWER
95’18.7 14.6OR
124’
80’
3/16” EHS(400#)
102’63’
33’ 87’
1/4” EHS(660#) 100’ ROHN 55G
Al l par ts shown intable are inc luded
when order ingPar t No: 55G130R100
TOWER PARTSINCLUDED
GUY WIRE &CONNECTION
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
10 1 1 3
33
FDNSBASE ANCHOR
3/16EHS
300’
5/16THH
6
1/4EHS
325’
3/8THH
6
142265
400’
7/16THH
6
BG2142
6
1/2TBE&J
6
BG2144
6
AGK1GGX
1
BG2146
6
TBSAFETY
3
5/8TBE&J
3
3
5/16” EHS(1100#)
P/N: 55G130R110
110’ TOWER
105’18.2 14.2OR
137’
88’
3/16” EHS(400#)
112’70’
35’ 95’
1/4” EHS(660#) 110’ ROHN 55G
Al l par ts shown intable are inc luded
when order ingPar t No: 55G130R110
TOWER PARTSINCLUDED
GUY WIRE &CONNECTION
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
11 1 1 3
33
FDNSBASE ANCHOR
3/16EHS
325’
5/16THH
6
1/4EHS
375’
3/8THH
6
142265
450’
7/16THH
6
BG2142
6
1/2TBE&J
6
BG2144
6
AGK1GGX
1
BG2146
6
TBSAFETY
3
5/8TBE&J
3
GAC5655TOP
3
5/16” EHS(1100#)
P/N: 55G130R120
120’ TOWER
115’17.7 14.0OR
150’
96’
3/16” EHS(400#)
123’77’
38’ 103’
1/4” EHS(660#) 120’ ROHN 55G
Al l par ts shown intable are inc luded
when order ingPar t No: 55G130R120
TOWER PARTSINCLUDED
GUY WIRE &CONNECTION
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
12 1 1 3
33
FDNSBASE ANCHOR
3/16EHS
350’
5/16THH
6
1/4EHS
400’
3/8THH
6
142265
500’
7/16THH
6
BG2142
6
1/2TBE&J
6
BG2144
6
AGK1GGX
1
BG2146
6
TBSAFETY
3
5/8TBE&J
3
GAC5655TOP
3
5/16” EHS(1100#)
P/N: 55G130R130
130’ TOWER
125’17.3 13.8OR
163’
104’
133’83’
42’ 112’
1/4” EHS(660#)
130’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G130R130
TOWER PARTSINCLUDED
GUY WIRE &CONNECTION
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
13 1 1 3
33
FDNSBASE ANCHOR
5/16THH
6
1/4EHS
425’
3/8THH
6
142265
525’
7/16THH
6
BG2142
6
1/2TBE&J
6
BG2144
6
AGK1GGX
1
BG2146
6
TBSAFETY
3
5/8TBE&J
3
GAC5655TOP
3
5/16” EHS(1100#)
CB2G AB2
CB2G AB3
CB2G AB3
CB2G AB3
11.6
11.6
11.6
11.6
GAC3455TOP
CPC.5/.75
CPC.5/.75
CPC.5/.75
CPC.5/.75
S T A N D A R D D E S I G N - 5 5 G1 3 0 M P H R E V . G , 1 1 0 M P H R E V . F
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
GG U Y E D T O W E R S - 5 5 G
105© 2010 ROHN PRODUCTS LLC
140’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G130R140
TOWER PARTSINCLUDED
GUY WIRE &CONNECTION
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
14 1 1 4
33
FDNSBASE ANCHOR
3/16EHS
875’
5/16THH
12
1/4EHS
500’
3/8THH
6
142265
575’
7/16THH
6
BG2142
12
1/2TBE&J
9
BG2144
6
AGK1GGX
1
BG2146
6
TBSAFETY
3
5/8TBE&J
3
GAC5655TOP
3
P/N: 55G130R140
140’ TOWER
135’16.9 13.6OR
232’
112’
200’101’
34’ 158’
67’175’ 3/16” EHS
(400#)
1/4” EHS(660#)
150’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G130R150
TOWER PARTSINCLUDED
GUY WIRE &CONNECTION
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
15 1 1 4
33
FDNSBASE ANCHOR
3/16EHS
900’
5/16THH
12
1/4EHS
525’
3/8THH
6
142265
600’
7/16THH
6
BG2142
12
1/2TBE&J
9
BG2144
6
AGK1GGX
1
BG2146
6
TBSAFETY
3
5/8TBE&J
3
GAC5655TOP
3
P/N: 55G130R150
150’ TOWER
145’16.6 13.4OR
188’
120’
161’108’
36’ 125’
72’140’ 3/16” EHS
(400#)
1/4” EHS(660#)
160’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G130R160
TOWER PARTSINCLUDED
GUY WIRE &CONNECTION
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
16 1 1 4
33
FDNSBASE ANCHOR
3/16EHS
950’
5/16THH
12
1/4EHS
550’
3/8THH
6
142265
650’
7/16THH
6
BG2142
12
1/2TBE&J
9
BG2144
6
AGK1GGX
1
BG2146
6
TBSAFETY
3
5/8TBE&J
3
GAC5655TOP
3
P/N: 55G130R160
160’ TOWER
155’16.3 13.2OR
201’
128’
173’116’
39’ 134’
78’150’ 3/16” EHS
(400#)
1/4” EHS(660#)
170’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G130R170
TOWER PARTSINCLUDED
GUY WIRE &CONNECTION
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
17 1 1 4
33
FDNSBASE ANCHOR
3/16EHS
500’
5/16THH
6
1/4EHS
1175’
3/8THH
12
142265
700’
7/16THH
6
BG2142
6
1/2TBE&J
9
BG2144
12
AGK1GGX
1
BG2146
6
TBSAFETY
3
5/8TBE&J
3
GAC5655TOP
3
5/16” EHS(1100#)
5/16” EHS(1100#)
5/16” EHS(1100#)
P/N: 55G130R170
170’ TOWER
165’16.0 13.0OR
214’
136’
184’124’
41’ 142’
83’159’ 3/16” EHS
(400#)
1/4” EHS(660#)
5/16” EHS(1100#)
CB3G AB3
CB3G AB3
CB3G AB3
CB3G AB4
11.0
10.0
9.8
9.6
CPC.5/.75
CPC.5/.75
CPC.5/.75
CPC.5/.75
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
G G U Y E D T O W E R S - 5 5 G
S T A N D A R D D E S I G N - 5 5 G1 3 0 M P H R E V . G , 1 1 0 M P H R E V . F
106© 2010 ROHN PRODUCTS LLC
180’ ROHN 55GAl l par ts shown intable are inc luded
when order ingPar t No: 55G130R180
TOWER PARTSINCLUDED
GUY WIRE &CONNECTION
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
18 1 1 5
33
FDNSBASE ANCHOR
3/16EHS
1000’
5/16THH
12
1/4EHS
1225’
3/8THH
12
142265
725’
7/16THH
6
BG2142
12
5/8TBE&J
15
BG2144
12
AGK1GGX
1
BG2146
6
TBSAFETY
3
GAC5655TOP
3
P/N: 55G130R180
180’ TOWER
175’15.8 12.9OR
227’
144’
201’
140’
35’
105’178’
3/16” EHS(400#)160’
148’
70’
5/16” EHS(1100#)
1/4” EHS(660#)
P/N: 55G130R190
190’ TOWER
185’15.5 12.7OR
239’
152’
214’
150’
41’
115’191’
173’
157’
82’
5/16” EHS(1100#)
1/4” EHS(660#) 190’ ROHN 55G
Al l par ts shown intable are inc luded
when order ingPar t No: 55G130R190
TOWER PARTSINCLUDED
GUY WIRE &CONNECTION
INCLUDED
ANCHORS &GROUNDINGINCLUDED
55G BPC55G APL55G GA55GD
BGK2GGX
19 1 1 5
33
FDNSBASE ANCHOR
5/16THH
12
1/4EHS
1425’
3/8THH
12
142265
775’
7/16THH
6
BG2142
12
5/8TBE&J
15
BG2144
12
AGK1GGX
1
BG2146
6
TBSAFETY
3
GAC5655TOP
3
CB3G AB4
CB4G AB49.0
9.2
CPC.5/.75
CPC.5/.75
GG U Y E D T O W E R S - 5 5 G
5’ SHORT BASESB55G
THESE BASE SECTIONS FOR EMBEDMENT IN CONCRETE.
CONCRETE BASE PLATEBPC55G*
FOR USE WITH PIER PIN EMBEDDED IN CONCRETE.
PIER PIN3/4x12PP
MUST BE ORDERED SEPARATELY.
* TOWERS MOUNTED ON THESE BASES MUST BE BRACKETED OR GUYED AT ALL TIMES. TEMPORARY STEEL GUYING MAY ALSO BE NECESSARY DURING INSTALLATION AND DISMANTLING.
BEARING PLATEBPL55G
CONVERTS STANDARD SECTION TO ATOP SECTION. SHOWN WITH TB3 (2” O.D.)THRUST BEARING. TB4 (3” O.D.) THRUST
BEARING ALSO AVAILABLE.
BEACON PLATEAPL55G
FOR MOUNTING BEACON. BOLTS TO TOP OF STANDARD SECTION.
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
P A R T S & A C C E S S O R I E S
107© 2010 ROHN PRODUCTS LLC
ACCESSORY SHELFAS455G
FOR MOUNTING MANY POPULARROTORS. FIELD DRILLING MAY BE NECESSARY FOR SOME ROTORS.
TORQUE ARM STABILIZERASSEMBLY
TA55SHOWN WITH 45TDM TOP DISH MOUNT.
FACE MOUNTDM55G2 - 2 3/8” O.D. 5’ LONG
DM554 - 4 1/2” O.D. PIPE, 5’ LONG
HEAVY DUTY UNIVERSALHOUSE BRACKET
HBUTVROADJUSTABLE TO POSITION TOWER
18” - 36” FROM WALL.
THRUST BEARINGTB3 - SUPPORTS UP TO 2” O.D. MAST.TB4 - SUPPORTS UP TO 3” O.D. MAST.
SIDE ARM BRACKETSA253UA
MOUNTING TUBE PROVIDED IS 3’ LONG, 2 - 1/4” O.D.
TOP MOUNT55TDMKD - NO PIPE
55TDM2S3KD - 2” PIPE55TDM25S3KD - 2 1/2” PIPE
55TDM3S3KD - 3” PIPE55TDM35S3KD - 3 1/2” PIPE
55TDM4S3KD - 4” PIPE
TAPERED BASE
55TG - STANDARD
55TGIA - USE WITH A4197L BASE INSULATOR
55TGIAA - USE WITH A4722B BASE INSULATOR
PIER PIN MUST BE ORDEREDSEPARATELY.
CLIMBING HARNESSTTFBH-4D
4D RING HARNESSTTFBH-C/P
PROFESSIONAL HARNESS
SAFETY CABLE SYSTEMORDERING INFORMATION
TOWER HEIGHT
50’100’150’200’250’300’350’400’
PARTNUMBER
TT0504555TT1004555TT1504555TT2004555TT2504555TT3004555TT3504555TT4004555
SAFETY CABLESLIDER
TT-WG-500-W/SMCWIRE ROPE GRAB WITH
CARABINEER.
G G U Y E D T O W E R S - 5 5 G
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
P A R T S & A C C E S S O R I E S
108© 2010 ROHN PRODUCTS LLC
ANTI-CLIMB PANELS455ACL3
BOLT ON SHEETS TO PROVIDE ANTI-CLIMBPROTECTION.
SAFETY RINGSR55
SNAPS INTO PLACE AT ANY LEVEL. NO BOLTS REQUIRED.
WORK PLATFORMWP55G
SNAPS INTO PLACE AT ANY LEVEL.NO BOLTS REQUIRED.
FLAT ROOF MOUNTFR55G
BOLTS DIRECTLY TO FLAT ROOF SURFACE.
GUY BRACKETGA55GD
MOUNTS TO ANY TOWER AT ANYHORIZONTAL BRACE.
TORQUE BARSTB55D
REQUIRES THREE 3/8s SHACKLES FORINSTALLATION. (NOT SHOWN)
12”
G U Y A N C H O R I N F O R M A T I O N
Ground Wire
6” Min. (152mm) Ground Rod Clamp
Ground Rod
* Clamp fits 1/2” - 3/4” O.D.
* Clamp is included in grounding kits for complete package towers only.
Attach to leg withsupplied leg clamp
Ground Wire
6” Min.(152mm)
Ground Rod Clamp
Ground Rod
GG U Y E D T O W E R S - 5 5 G
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard 109© 2010 ROHN PRODUCTS LLC
3/8”
2”
ANCHOR GROUNDINGAGK1GGX
81”
3/4”
2 1/2”
P/N STAMPED HERE
GAC3455TOP( 17,670 LBS. ALLOWABLE LOAD)*
ANCHOR RODSNotes:1. GAC303 rods are supplied with type EP25343 and EP25345 equalizer plates.2. Part number suffixes 3, 5 and 55 denotes 3 or 5 holes in equalizer plates.3. Type EE equalizer plates are supplied in pairs for eye and eye turnbuckles.4. Type EJ equalizer plates are used with eye and jaw turnbuckles.
* INCLUDES 33.33 INCREASE IN ALLOWABLE STRESSES. Anchor Rod capacities are calculated per ANSI/TIA/EIA-222-F.
BASE GROUNDINGBGK3GGX
1/2”12”
120”
1 1/4”
3”
P/N STAMPED HERE
GAC5655TOP( 49,060 LBS. ALLOWABLE LOAD)*
2 1/2”
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
G G U Y E D T O W E R S - 5 5 G
110© 2010 ROHN PRODUCTS LLC
S T A N D A R D D E S I G NA N C H O R B L O C K S
Anchor Detail for:GAC34, 56, 57 & 58
E
3” Min.
All around stirrupsequally spaced 12” O.C.
NOTE:1. Due to variables involved during installation, it shall be the customer’s or installer’s responsibility to provide structurally adequate supports for pier and anchor connections. It may also be necessary for the customer or installer to secure the service of a local engineer to determine that installation complies with local building codes.2. Additional corrosion protection may be required for steel guy anchors in direct contact with soil.
* #3 Stirrups equally spaced 12” O.C.** #4 Stirrups equally spaced 12” O.C.
Anchor Detail for:GAC30 & GAR30
Horizontal bars equallyspaced all around
C
3” Min.
B
A
Ground LineGroundLine
D
May be singleor double roddepending ontype used
All around stirrupsequally spaced 12” O.C.
Horizontal bars equallyspaced all aroundE
Ground Line
3” Min.
3” Min.
B
A
D
Block
AB1*
AB2*
AB3*
AB4**
AB5**
AB6**
A
3’ - 0”
4’ - 0”
6’ - 0”
6‘ - 0”
8’ - 0”
8’ - 0”
BarSpacing
10” O.C.
10.5” O.C.
10” O.C.
10.5” O.C.
10” O.C.
10.5” O.C.
Concrete Vol.(Cu. Yds.)
Round Pier0.44 Per Block1.3 Total for 3
1.33 Per Block4.0 Total for 3
1.0 Per Block3.0 Total for 3
2.0 Per Block6.0 Total for 3
2.22 Per Block6.7 Total for 3
2.96 Per Block8.9 Total for 3
B
1’ - 0”
1‘ - 6”
1’ - 6”
1’ - 6”
2’ - 0”
2’ - 0”
C
3’ - 0”
4‘ - 0“
3’ - 0”
4‘ - 0“
3’ - 0”
4’ - 0”
Horizontal Bars
(Qty. & Size)(4) #5 Bars, Top Layer
(4) #5 Bars, Bottom Layer
(5) #6 Bars, Top Layer(5) #6 Bars, Bottom Layer
(4) #6 Bars, Top Layer(4) #6 Bars, Bottom Layer
(5) #6 Bars, Top Layer(5) #6 Bars, Bottom Layer
(4) #7 Bars, Top Layer(4) #7 Bars, Bottom Layer
(5) #7 Bars, Top Layer(5) #7 Bars, Bottom Layer
D
4’ - 0”
6’ - 0”
6’ - 0”
9’ - 0”
10’ - 0”
10’ - 0”
Anchor Dimensions (in.)
GroundLine
C
CL
(See tower assembly drawing for anchor rod slope ‘E’)
GG U Y E D T O W E R S - 5 5 G
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard 111© 2010 ROHN PRODUCTS LLC
S T A N D A R D B A S E F O U N D A T I O N S
AlternateSquarePier
PLAN VIEW
A
B
No. 4 Circular ties, 3” O.C. with 24” laps
Vertical bars equally spaced
Pier Pin
(2) No. 4 Circular ties, 2-1/2” O.C. with 2“ cover with 24” laps
4” Projection
6”
No. 4 Circular ties, 3” Max. O.C. with 24” laps
Vertical re-bars equally spacedwith 90 hooks at bottom
Roughen construction joint toa full amplitude of 1/4”
Foundation Pad
Horizontal reinforcing steel equally spacedeach way
C
E
D
F
ELEVATION VIEW
B
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
G G U Y E D T O W E R S - 5 5 G
112© 2010 ROHN PRODUCTS LLC
S T A N D A R D B A S E F O U N D A T I O N SF O R 5 5 G T O W E R S
NOTES: 1. See tower assembly drawing for foundation layout and part numbers for bearing plate and pier pin.*2. Use minimum 2’ - 6” sq. or 3’ - 0” diameter round pier when BPC45G or BPC55G is used. 3. Vertical reinforcing steel shall be replaced with straight bars when no pad is required. 4. Horizontal bars in chart refer only to the bars in the foundation pad (each way).
CB No.
1G
2G
3G
4G
5G
6G
7G
8G
9G
10G
11G
12G
13G
14G
15G
A
2’ - 6”
3’ - 0”
3’ - 6”
4’ - 0”
2’ - 0”
2’ - 0”
2’ - 0”
2’ - 0”
2’ - 0”
2’ - 0”
2’ - 6”
2’ - 6”
2’ - 6”
3’ - 0”
3’ - 0”
Vertical Bars(No. & Size)
(8) #7
(10) #7
(12) #7
(12) #8
(8) #6
(8) #6
(8) #6
(8) #6
(8) #6
(8) #6
(8) #7
(8) #7
(8) #7
(12) #7
(12) #7
Concrete Vol.(Cu. Yds.)
Round Pier
0.80
1.20
1.60
2.10
1.10
1.30
1.60
1.80
2.40
2.80
3.90
4.30
4.80
6.30
6.90
B
2’ - 6”
3’ - 0”
3’ - 6”
4’ - 0”
4’ - 0”
4’ - 6”
5’ - 0”
5’ - 6”
6’ - 0”
6’ - 6”
7’ - 0”
7’ - 6”
8’ - 0”
8’ - 6”
9’ - 0”
C
0
0
0
0
1’ - 0”
1’ - 3”
1’ - 6”
1’ - 9”
2’ - 0”
2’ - 3”
2’ - 3”
2’ - 6”
2’ - 9”
2’ - 9”
3’ - 0”
Horiz. Barsin Pad**
(No. & Size)
NONE
NONE
NONE
NONE
(5) #5
(6) #5
(6) #5
(7) #5
(7) #6
(8) #5
(8) #6
(9) #6
(9) #6
(9) #7
(10) #7
D
4’ - 0”
4’ - 0”
4’ - 0”
4’ - 0”
4’ - 0”
4’ - 0”
4’ - 6”
4’ - 6”
4’ - 6”
4’ - 6”
5’ - 0”
5’ - 0”
5’ - 0”
5’ - 0”
5’ - 0”
E
0
0
0
0
3’ - 3”
3’ - 3”
3’ - 9”
3’ - 9”
3’ - 6”
3’ - 6”
3’ - 9”
3’ - 9”
3’ - 9”
3’ - 6”
3’ - 6”
F
0
0
0
0
1’ - 3”
1’ - 3”
1’ - 3”
1’ - 3”
1’ - 6”
1’ - 6”
1’ - 9”
1’ - 9”
1’ - 9”
2’ - 0”
2’ - 0”
*
**