Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
S E L F - S U P P O R T I N G T O W E R S
186© 2011 ROHN PRODUCTS LLC
S S V S E L F - S U P P O R T I N G T O W E R S
20’ 2W
20’ 3WN
20’ 4N
20’ 5N
20’ 6N
20’ 7N
20’ 8N
20’ 9N
20’ 10N
20’ 11N
20’ 12N
20’ 13N
20’ 14N
20’ 15N
20’ 16N
Field BoltedConstruction
All-WeldedConstruction
SectionNumber Upper Lower
NominalSpread Dimension
1WB
2W
3WN
4N
5N
6N
7N
8N
9N
10N
11N
12N
13N
14N
15N
16N
1’ - 2”
1’ - 2”
1‘ - 6“
1’ - 10”
2’ - 2”
2’ - 6”
4’ - 6 1/4”
6’ - 6 3/4”
8’ - 6 3/4”
10’ - 6 3/4”
12’ - 7 1/4”
14’ - 7 7/8”
16’ - 8 3/8”
18’ - 8 3/8”
20’ - 9 3/8”
22’ - 9 3/8”
1’ - 2”
1’ - 6”
1‘ - 10“
2’ - 2”
2’ - 6”
4’ - 6 1/4”
6’ - 6 3/4”
8’ - 6 3/4”
10’ - 6 3/4”
12’ - 7 1/4”
14’ - 7 7/8”
16’ - 8 3/8”
18’ - 8 3/8”
20’ - 9 3/8”
22’ - 9 3/8”
24’ - 9 3/8”
SS
GENERAL USE
The ROHN SSV tower has been in service for over50 years. The design utilizes standard partsarranged to create a unique structure. The legsare tubular with angle braces at the bottom andsolid legs and braces in the top sections. This tower is used in a variety of applications, fromPCS structures and broadband to security, sportslighting and more. The SSV has proven to be one of the industry’s most e�cient and preferredstructures. All ROHN SSV towers are hot-dipgalvanized, inside and out for corrosion protection.
SSVSTANDARD
Per Rev G requirements, any structure greater than 10’ requires a climber safety device. Please contact ROHN for ordering information.
10’ 1WB
SS040D70
SS050D70
SS060D70
SS070D70
SS080D70
SS090D70
SS100D70
SS110D70
SS120D70
SS130D70
SS140D70
SS150D70
SS160D70
SS170D70
SS180D70
SS190D70
2W
1WB
2W
1WB
2W
1WB
2W
1WB
2W
1WB
2W
1WB
2W
1WB
2W
1WB
3WN
3WN
4N
4N
5N
5N
6N
6N
7N
7N
8N
8N
9N
9N
10N
10N
SB3
SB3
SB4
SB4
SB5
SB5
-
-
-
-
-
-
-
-
-
-
16.7 (10)
15 (9)
15 (9)
13.3 (8)
13.8 (8)
11.7 (7)
11.7 (7)
10 (6)
10 (6)
9.2 (5.5)
9.2 (5.5)
8.3 (5)
8.3 (5)
7.5 (4.5)
7.5 (4.5)
6.7 (4)
20 (12)
18.3 (11)
18.3 (11)
16.7 (10)
16.7 (10)
15 (9)
15 (9)
14.2 (8.5)
14.2 (8.5)
13.3 (8)
13.3 (8)
12.5 (7.5)
12.5 (7.5)
12.5 (7.5)
12.5 (7.5)
11.7 (7)
S E L F - S U P P O R T I N G S T A N D A R D T O W E R S4 0 ’ - 1 9 0 ’
7 0 M P H R E V F . [ N O I C E ]
TowerAssemblyNumber
TowerHeight
(ft.)
TopSection
Base Section
SectionNumber
ShortBase P/N
Allowable Projected Area
Tower TopRounds (Flats)
30’ Below TopRounds (Flats)
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
S E L F - S U P P O R T I N G T O W E R S
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard© 2011 ROHN PRODUCTS LLC
187
SS
General Notes:1. Standard tower designs are in accordance with approved national standard ANSI/EIA-222-F (no ice).2. Equivalent flat-plate antenna areas based on EIA RS-222-C, must not exceed the areas shown for flat members. 3. Tower designs assume allowable projected areas are symmetrically placed on the tower.4. Designs assume one 7/8 line to top and two 7/8 lines to 30 feet below top, one line on each face.5. All towers are provided with a tapered top.6. A Rev F grounding kit is provided with each tower.7. Assembly drawings and standard foundation details are supplied with the tower.8. Custom designs for site-specific applications are available upon request.
Assy. P/N Tower Section No.
1TT
3TT
4TTN5TTN6TT
1W, 1WB, 2W
2WST, 2WB, 3WN
3WNST, 3WNB, 4N4NST, 4NA, 4WB, 4NC, 5N5NST, 5NA, 5NB, 5NC, 6C
Tapered Top
14”2 3/8” O.D. Tube
495
564
1012
1077
1441
1505
1863
1927
2449
2513
3173
3248
3952
4017
4816
4880
TowerWeight
(lbs.)
-
-
-
-
-
-
5/8X42
5/8X42
5/8X42
5/8X42
5/8X42
5/8X42
5/8X42
5/8X42
3/4X48
3/4X48
A-Bolts(12 Req.)
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
S E L F - S U P P O R T I N G T O W E R S
188© 2011 ROHN PRODUCTS LLC
S E L F - S U P P O R T I N GS T A N D A R D S E C T I O N S
SS
Bracing Detail for Tapered Sections 6N - 16NTubular Legs & Angle Braces Part No: SB2, SB3, SB4 & SB5
Installed when 2N - 5N sections areused as tower base.
TYPICAL SHORT BASE
Bracing Detail for Sections 1W - 3WNSolid Round Legs & Solid Round Braces
Straight and Tapered Sectionsavailable.
Bracing Detail for Straight Sections 6N - 11NTubular Legs & Angle Braces
Bracing Detail for Sections 4N & 5NSolid Round Legs & Solid Round Braces
Straight and Tapered Sectionsavailable.
Anchor bolt con�gurations are provided with larger towers.
Pier & PadElevation View
6” Grade
Horizontal Barseach way
Vert. Barsequallyspaced
D
CircularTies
2’
C
A(square)
Y
Drilled PierElevation View
6”
D
CircularTies
Vert. Barsequallyspaced
Section A-A
YY
Vertical Bars
AA
MatElevation View
Tower Axisand center
of pad
Plan View
Horizontal bars each way,top and bottom
6”
4’
W(square)
Round or Square Pier
Tower Axis
Plan View
Grade Grade
S E L F - S U P P O R T I N G T O W E R S
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard© 2011 ROHN PRODUCTS LLC
189
SSS E L F - S U P P O R T I N G
S T A N D A R D F O U N D A T I O N S
TowerBaseSect.No.
Pier & Pad
D A C
Dimensions Req’d Conc.(cu. yds.3 fdns)
Mat
WReq’dConc.
(cu. yds.)D Y
Req’dConc.
(cu. yds.)
Drilled Pier
1W2W
3WN4N5N6N7N8N9N
10N11N12N13N14N15N16N
------
8‘ - 0”8’ - 9”8‘ - 9”8’ - 9”
10‘ - 0”10’ - 0”11‘ - 0”11’ - 0”12‘ - 6”12’ - 6”
------
4’ - 6”5‘ - 6”5’ - 6”5‘ - 6”5’ - 6”5‘ - 6”5’ - 6”5‘ - 6”6 ‘- 6”6’ - 6”
------
2‘ - 0”2’ - 0”2‘ - 0”2’ - 0”2‘ - 6”2’ - 6”2‘ - 6”2’ - 6”3‘ - 0”3’ - 0”
Round Square------
6.38.78.78.7
10.810.811.311.317.317.3
------
6.99.49.49.4
12.012.012.712.719.719.7
4’ - 0”5’ - 6”6’ - 9”8’ - 0”8’ - 9”
10’ - 3”11’ - 6”14’ - 3“16’ - 0”18’ - 3”
------
2.44.56.89.5
11.315.619.630.137.949. 3
------
-------
18’ - 6”16’ - 0”16’ - 0”21’ - 9”21’ - 6”22’ - 0”22’ - 0”27’ - 6”27’ - 6”
-------
2’ - 6”2‘ - 6”2’ - 6”2‘ - 6”2’ - 6”3‘ - 0”3’ - 0”3‘ - 6”3’ - 6”
-------
10.49.09.0
12.212.017.717.730.030.0
Standard foundations illustrated are for general information purposes only and are based on Rev F normal soil parameters. Foundation installation details are provided with tower assembly drawings.
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
S E L F - S U P P O R T I N G T O W E R S
190© 2011 ROHN PRODUCTS LLC
SSV HD SELF-SUPPORTING TOWERS
20’ 3WN10’
3WNB
20’ 4N
20’ 5N
20’ 6N
20’ 7N
20’ 8N
20’ 9NH
20’ 10NH
20’ 11N
20’ 12NH
20’ 13NH
20’ 14NH
20’ 15NH
20’ 16NH
Field BoltedConstruction
3WN
3WNB
4N
5N
6N
7N
8N
9NH
10NH
11N
12NH
13NH
14NH
15NH
16NH
1’ - 6”
1’ - 10”
1’ - 10”
2’ - 2”
2’ - 6”
4’ - 6 1/4”
6’ - 6 3/4”
8’ - 6 3/4”
10’ - 6 3/4”
12’ - 7 1/4”
14’ - 7 7/8”
16’ - 8 3/8”
18’ - 8 3/8”
20’ - 9 3/8”
22’ - 9 3/8”
1’ - 10”
1’ - 10”
2’ - 2”
2’ - 6”
4’ - 6 1/4”
6’ - 6 3/4”
8’ - 6 3/4”
10’ - 6 3/4”
12’ - 7 1/4”
14’ - 7 7/8”
16’ - 8 3/8”
18’ - 8 3/8”
20’ - 9 3/8”
22’ - 9 3/8”
24’ - 9 3/8”
SectionNumber Upper Lower
NominalSpread Dimension
SS
GENERAL USE
The ROHN SSV HD tower has the same featuresand utility as the SSV tower, but with Heavy Dutylegs and braces. The heavy duty tower allows forthe structure to support more loading and higherwind and ice loading. This tower serves the sameapplications as the SSV including: PCS, broadband,security, sports lighting and many others. TheSSV HD also has standard “pre-engineered” towerscreated from standard sections. All ROHN SSVtowers are hot-dip galvanized, inside and out for corrosion protection.
SSVHEAVY DUTY
Per Rev G requirements, any structure greater than 10’ requires a climber safety device. Please contact ROHN for ordering information.
All-WeldedConstruction
Tapered Top
14”2 3/8” O.D. Tube
S E L F - S U P P O R T I N G H E A V Y D U T Y S T A N D A R D T O W E R S4 0 ’ - 1 9 0 ’
9 0 M P H R E V . F [ N O I C E ]
TowerAssemblyNumber
TowerHeight
(ft.)
TopSection
Base Section
SectionNumber
ShortBase P/N
Allowable Projected Area
Tower TopRounds (Flats)
30’ Below TopRounds (Flats)
SS040D90
SS050D90
SS060D90
SS070D90
SS080D90
SS090D90
SS100D90
SS110D90
SS120D90
SS130D90
SS140D90
SS150D90
SS160D90
SS170D90
SS180D90
SS190D90
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
3WN
3WNB
3WN
3WNB
3WN
3WNB
3WN
3WNB
3WN
3WNB
3WN
3WNB
3WN
3WNB
3WN
3WNB
4N
5N
5N
6N
6N
7N
7N
8N
8N
9NH
9NH
10NH
10NH
11N
11N
12NH
SB4
SB5
SB5
-
-
-
-
-
-
-
-
-
-
-
-
-
16.7 (10)
16.7 (10)
14.2 (8.5)
14.2 (8.5)
12.5 (7.5)
12.5 (7.5)
10 (6)
10 (6)
8.3 (5)
8.3 (5)
6.7 (4)
6.7 (4)
5.8 (3.5)
5.8 (3.5)
5 (3)
5 (3)
20 (12)
20 (12)
17.5 (10.5)
17.5 (10.5)
15.8 (9.5)
15.8 (9.5)
13.3 (8)
13.3 (8)
11.7 (7)
11.7 (7)
10 (6)
10 (6)
8.3 (5)
8.3 (5)
7.5 (4.5)
7.5 (4.5)
S E L F - S U P P O R T I N G T O W E R S
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard© 2011 ROHN PRODUCTS LLC
191
SS
General Notes:1. Standard tower designs are in accordance with approved national standard ANSI/EIA-222-F (no ice).2. Equivalent flat-plate antenna areas based on EIA RS-222-C, must not exceed the areas shown for flat members. 3. Tower designs assume allowable projected areas are symmetrically placed on the tower.4. Designs assume one 7/8 line to top and two 7/8 lines to 30 feet below top, one line on each face.5. All towers are provided with a tapered top.6. A Rev F grounding kit is provided with each tower.7. Assembly drawings and standard foundation details are supplied with the tower.8. Custom designs for site-specific applications are available upon request.
Assy. P/N Tower Section No.
1TT
3TT
4TTN5TTN6TT
1W, 1WB, 2W
2WST, 2WB, 3WN
3WNST, 3WNB, 4N4NST, 4NA, 4WB, 4NC, 5N5NST, 5NA, 5NB, 5NC, 6C
TowerWeight
(lbs.)
853
1198
1282
1620
1704
2206
2290
2941
3025
3829
3913
4810
4894
5712
5796
8045
A-Bolts(12 Req.)
-
-
-
5/8X42
5/8X42
5/8X42
5/8X42
5/8X42
5/8X42
5/8X42
5/8X42
3/4X48
3/4X48
7/8X60
7/8X60
7/8X60
TYPICAL SHORT BASE
Part No: SB2, SB3, SB4 & SB5Installed when 2N - 5N sections are
used as tower base.
Bracing Detail for Sections 1W - 3WNSolid Round Legs & Solid Round Braces
Straight and Tapered Sectionsavailable.
Bracing Detail for Straight Sections 6N - 11NTubular Legs & Angle Braces
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard
S E L F - S U P P O R T I N G T O W E R S
192© 2011 ROHN PRODUCTS LLC
S E L F - S U P P O R T I N GH E A V Y D U T Y S E C T I O N S
SS
Bracing Detail for Sections 4N & 5NSolid Round Legs & Solid Round Braces
Straight and Tapered Sectionsavailable.
Bracing Detail for Tapered Sections 6N - 16NHTubular Legs & Angle Braces
Anchor bolt con�gurations are provided with larger towers.
S E L F - S U P P O R T I N G T O W E R S
Phone (309) 566-3000 • Fax (309) 566-3079 • www.rohnnet.com • The Industry Standard© 2011 ROHN PRODUCTS LLC
193
SS
TowerBaseSect.No.
Pier & Pad
D A C
Dimensions Req’d Conc.(cu. yds.3 fdns)
Mat
WReq’dConc.
(cu. yds.)D Y
Req’dConc.
(cu. yds.)
Drilled Pier
1W2W
3WN4N5N6N7N8N
9NH10NH11N
12NH13NH14NH15NH16NH
Round Square------
8’ - 0”8’ - 9”9’ - 0”9’ - 0”
10’ - 0”11’ - 0”12‘ - 0”12’ - 0”13‘ - 0”13’ - 0”
------
4’ - 6”5‘ - 6”5’ - 6”5‘ - 6”5’ - 6”5‘ - 6”6’ - 3”6’ - 3”7‘ - 3”7‘ - 3”
------
2’ - 0”2’ - 0”2’ - 0”2’ - 0”2‘ - 6”2’ - 6”3’ - 0”3’ - 0”3‘ - 0”3’ - 0”
------
6.38.78.88.8
10.811.316.316.319.919.9
------
6.99.49.59.5
12.012.718.518.522.422.4
4’ - 0”5’ - 6”6’ - 9”8’ - 0”8’ - 9”
10’ - 3”11’ - 6”14’ - 3”16’ - 0”18’ - 3”
------
2.44.56.89.5
11.315.619.630.137.949. 3
------
-------
18’ - 6”19’ - 6”19’ - 6”21’ - 9”22’ - 9”25’ - 0”25’ - 0”30’ - 0”30’ - 0”
-------
2’ - 6”2’ - 6”2’ - 6”2’ - 6”3’ - 0”3’ - 6”3’ - 6”4’ - 0”4’ - 0”
-------
10.410.910.912.218.327.327.342.642.6
S E L F - S U P P O R T I N GH E A V Y D U T Y S T A N D A R D F O U N D A T I O N S
Pier & PadElevation View
6” Grade
Horizontal Barseach way
Vert. Barsequallyspaced
D
CircularTies
2’
C
A(square)
Y
Drilled PierElevation View
6”
D
CircularTies
Vert. Barsequallyspaced
Section A-A
YY
Vertical Bars
AA
MatElevation View
Tower Axisand center
of pad
Plan View
Horizontal bars each way,top and bottom
6”
4’
W(square)
Round or Square Pier
Tower Axis
Plan View
Grade Grade
Standard foundations illustrated are for general information purposes only and are based on Rev F normal soil parameters. Foundation installation details are provided with tower assembly drawings.