122
Mull-1 19972255 Marvin Architectural Detail Manual General Mulling Information General Mull Information - Mull Types ............................................................................................................................. 3 Clad Ultimate Casement Mull Types ................................................................................................................................9 Clad Ultimate Replacement Casement Mull Types ........................................................................................................23 Clad Direct Glaze Mull Types .........................................................................................................................................37 Clad Direct Glaze Round Top Mull Types .......................................................................................................................49 Clad Narrow Frame (Contemporary) Direct Glaze Mull Types ........................................................................................61 Clad Ultimate Double Hung - NG 2.0 Mull Types ............................................................................................................75 Clad Ultimate Glider Mull Types .....................................................................................................................................91 Multi-High, Multi-Wide Mulling ......................................................................................................................................101 Clad Ultimate Inswing French Door Mull Types ............................................................................................................107 Clad Ultimate Outswing French Door Mull Types .........................................................................................................111 Clad Ultimate Sliding French Door Mull Types .............................................................................................................115 Clad Sliding Patio Door Mull Types ..............................................................................................................................119

General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Embed Size (px)

Citation preview

Page 1: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

General Mulling Information

General Mull Information - Mull Types ............................................................................................................................. 3Clad Ultimate Casement Mull Types ................................................................................................................................9Clad Ultimate Replacement Casement Mull Types ........................................................................................................23Clad Direct Glaze Mull Types .........................................................................................................................................37Clad Direct Glaze Round Top Mull Types .......................................................................................................................49Clad Narrow Frame (Contemporary) Direct Glaze Mull Types ........................................................................................61Clad Ultimate Double Hung - NG 2.0 Mull Types ............................................................................................................75Clad Ultimate Glider Mull Types .....................................................................................................................................91Multi-High, Multi-Wide Mulling ......................................................................................................................................101Clad Ultimate Inswing French Door Mull Types ............................................................................................................107Clad Ultimate Outswing French Door Mull Types .........................................................................................................111Clad Ultimate Sliding French Door Mull Types .............................................................................................................115Clad Sliding Patio Door Mull Types ..............................................................................................................................119

Mull-1 19972255Marvin Architectural Detail Manual

Page 2: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

General Mulling Information

Mull-2 19972255Marvin Architectural Detail Manual

Page 3: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

General Mulling Information

General Mull Information - Mull Types

Marvin offers a variety of mull options for many of the Marvin window and door projects. Some mulls can be done in the factory.Others would need to be done in the field. Some mulls create a certified assembly according to third-party testing.

Marvin Mull Options:

Marvin-Supplied Standard Mull: Two units mulled directly together without any reinforcement or space mulls between the frames.

3/8" Mull Reinforcement (MRF): A two-piece, thermally-broken aluminum reinforcement that allows for either factory or fieldassembly of the mullion.

Solid Space Mull: Solid continuous wood piece is used to reinforce the units and space them apart.

◦ 3/8", 1", 2", 3", 4" and 6" widths are available. LVL Mull Reinforcement: Laminated Veneered Lumber is used as a solid space mull.

◦ LVL is 1.7 to 1.9 times stronger than regular wood.

◦ 1" and 2" widths are available from Marvin. Space Mull: Non-continuous blocks of wood are used to space units apart.

◦ 3/8", 1", 2", 3", 4" and 6" widths are available. Stud Pocket: An exterior mull cap is applied to the units with a space in between the units to allow for installation of an existing

structure in the opening. Units are shipped with temporary blocking. Remove before installation.

Field Supplied and Applied (these are other available mulling options, not provided by Marvin) Tube Mull: Tube aluminum or steel used to reinforce mulled assemblies.

Flat Mull: Flat Steel or Aluminum used to reinforce mulled assemblies.

These reinforcement types must be primed to prevent corrosion.

Anchoring Special considerations need to be made when installing mulled assemblies. Mullions create point loads that need to be

transferred to the rough opening. For Marvin standard, MRF, LVL, and space mulls, the ends of the mull need to be fastened oneach side of the splice with either jamb screws or brackets. Aluminum, steel and other structural mulls need to be anchoreddirectly to the rough opening or building structure.

Section Details:

Cross sections will illustrate the mulling of two units.

Tributary and Span:

Tributary Width - The area supported by the mullion. In the case of a vertical mull, this is equal to the sum of half of the width of eachunit on each side of the mull.

Span - The length of the mullion

TributaryWidth

Span

TributaryWidth

TributaryWidth

TributaryWidth

Span

Ribbon Mull Stacked Mull

Mull-3 19972255Marvin Architectural Detail Manual

Ver 2017.6 2017-12-18

Page 4: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

General Mulling Information

General Mull Information - Mull Types

Charts:

Mullion Performance Charts

In accordance with the International Building Code, mullion performance is determined through either physical testing or calculations. A combination of both methods has been used to develop the performance charts. Calculated mulls limit deflection to L/175 (L=length of mullion) and limit allowable stress to 2/3 of the mull material’s allowable stress. Physically tested mulls often outperform calculations and this will show up on the charts as jumps in performances.

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 8824-58

59606162 PG 65 DP 50 636465666768 DP 40 697071727374 PG50 DP 30 75767778798081828384 DP 20 85 DP 50 86878889909192939495969798 PG4099

100101102103104105106107108109110 DP30111 DP20112113114115116117118119120

Span

Tributary Width

Tested Sizes

Tested Size

Calculated Range

Mull-4 19972255Marvin Architectural Detail Manual

Ver 2017.6 2017-12-18

Page 5: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

General Mulling Information

Field-Supplied and Applied Mull Types

Mull-5 19972255Marvin Architectural Detail Manual

Ver 2017.6 2017-12-18

Page 6: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

General Mulling Information

Marvin Mull Types

NOTE: Mulls displayed with Clad Ultimate Casement frames, but other products can also be used.

Mull-6 19972255Marvin Architectural Detail Manual

Ver 2017.6 2017-12-18

Page 7: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

General Mulling Information

Marvin Mull Types

NOTE: Mulls displayed with Clad Ultimate Casement frames, but other products can also be used.

Mull-7 19972255Marvin Architectural Detail Manual

Ver 2017.6 2017-12-18

Page 8: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

General Mulling Information

Mull-8 19972255Marvin Architectural Detail Manual

Ver 2017.6 2017-12-18

Page 9: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Ultimate Casement Mull Types

Marvin offers a variety of mull options for many of the Marvin window and door projects. This document is a compilation of mullingoptions for the Clad Ultimate Casement product.

Mull Types: Standard Mull: Two units mulled directly together without any reinforcement or space mulls between the frames.

3/8" Mull Reinforcement (MRF): A two-piece, thermally-broken aluminum reinforcement that allows for either factory or fieldassembly of the mullion.

Space Mull: Non-continuous blocks of wood are used to space units apart.

◦ 3/8", 1", 2", 3", 4" and 6" widths are available. Solid Space Mull: Solid continuous wood piece is used to reinforce the units and space them apart.

◦ 3/8", 1", 2", 3", 4" and 6" widths are available. LVL Mull: Laminated Veneered Lumber is used as a solid space mull.

◦ LVL is 1.7 to 1.9 times stronger than regular wood.

◦ 1" and 2" widths are available. Stud Pocket: An exterior mull cap is applied to the units with a space in between the units to allow for installation around an

existing structure in the opening.

Products IncludedClad Ultimate Casement and Awning

Clad Ultimate Casement Picture

Clad Ultimate Venting Picture

Clad Ultimate Pushout Casement and Awning

Clad Ultimate French Casement and Push Out French Casement

IZ3 StormPlus

Certified Mull Installation Methods:Masonry Clips

Jamb Screws

Structural Brackets

Tributary and Span:

Tributary Width - In the case of a vertical mull, this is equal to the sum of half of the width of each unit on each side of the mull. Inthe case of a horizontal mull, this is equal to the sum of half of the height of each unit on each side of the mull.

Span - The length of the mullion.

TributaryWidth

Span

TributaryWidth

TributaryWidth

TributaryWidth

Span

Ribbon Mull Stacked Mull

Mull-9 19972255Marvin Architectural Detail Manual

Ver 2018.1 2018-02-26

Page 10: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Section Details: Clad Ultimate Casement Mulling Types

Mull-10 19972255Marvin Architectural Detail Manual

Ver 2017.6 2017-12-18

Page 11: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Section Details: Clad Ultimate Casement Mulling Types (Continued)

Space Mulls and Solid Space Mulls are available in3/8", 1", 2", 3", 4" and 6" widths.

Marvin provides interior mull trim for mulls up to 2".

Mull-11 19972255Marvin Architectural Detail Manual

Ver 2017.6 2017-12-18

Page 12: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Ultimate Casement Mulling - Standard Frame (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 8824-58 DP 65

59606162 PG 65 DP 50 636465666768 DP 40 697071727374 PG50 DP 30 75767778798081828384 DP 20 85 DP 50 86878889909192939495969798 PG4099

100101102103104105106107108109110 DP30111 DP20112113114115116117118119120

Span

Tributary Width

Mull-12 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 13: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Ultimate Casement Mulling - 3/8" Mull Reinforcement (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 8824-58

596061 DP65626364656667686970717273 DP50747576777879808182 DP408384858687888990919293949596979899

100 DP40101102103104 DP30105106107 DP20108109110111112113 DP25114115116117118119120

Span

Tributary Width

Mull-13 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 14: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Ultimate Casement Mulling - 1" LVL (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 8824-58

596061 DP65626364656667686970717273747576 DP5077787980818283848586878889909192 DP4093949596979899

100 DP30101102103104105106107108109110 DP20111112113114115116117118119120

Tributary Width

Span

Mull-14 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 15: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Ultimate Casement Mulling - 2" LVL (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 8824-58

596061 DP65626364656667686970717273747576 DP5077787980818283848586878889909192 DP4093949596979899

100 DP30101102103104105106107108109110111112113114115 DP20116117118119120

Span

Tributary Width

Mull-15 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 16: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Ultimate Casement Mulling - 3/8" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 8824-58

5960 DP6561626364656667 DP5068697071727374 DP407576777879808182 DP3083848586878889909192 DP2093949596979899

100101102103104105106107108109110111112113114115116117118119120

Tributary Width

Span

Mull-16 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 17: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Ultimate Casement Mulling - 1" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 8824-58

5960 DP6561626364656667 DP5068697071727374 DP407576777879808182 DP3083848586878889909192 DP2093949596979899

100101102103104105106107108109110111112113114115116117118119120

Tributary Width

Span

Mull-17 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 18: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Ultimate Casement Mulling - 2" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 8824-58

596061 DP6562636465666768697071 DP5072737475767778798081 DP408283848586878889909192939495 DP3096979899

100101102103104105106107108 DP20109110111112113114115116117118119120

Tributary Width

Span

Mull-18 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 19: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Ultimate Casement Mulling - 3" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 8824-58

596061 DP6562636465666768697071 DP507273747576777879808182 DP408384858687888990919293949596 DP30979899

100101102103104105106107108109110111112113114115 DP20 116117118119120

Span

Tributary Width

Mull-19 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 20: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Ultimate Casement Mulling - 4" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88

24-58

59

60

61

62 DP65

63

64

65

66

67

68

69

70

71 DP50

72

73

74

75

76

77

78

79

80

81 DP40

82

83

84

85

86

87

88

89

90

91

92

93

94 DP30

95

96

97

98

99

100

101

102

103

104

105

106

107

108

109 DP20

110

111

112

113

114

115

116

117

118

119

120

Span

Tributary Width

Mull-20 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 21: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Ultimate Casement Mulling - 6" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 8824-58

596061 DP6562636465666768697071 DP5072737475767778798081 DP4082838485868788899091929394 DP309596979899

100101102103104105106107108109110111 DP20112113114115116117118119120

Span

Tributary Width

Mull-21 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 22: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Mull-22 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 23: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Ultimate Replacement Casement Mull Types

Marvin offers a variety of mull options for many of the Marvin window and door projects. This document is a compilation of mullingoptions for the Clad Ultimate Replacement Casement product.

Mull Types: Standard Mull: Two units mulled directly together without any reinforcement or space mulls between the frames.

3/8" Mull Reinforcement (MRF): A two-piece, thermally-broken aluminum reinforcement that allows for either factory or fieldassembly of the mullion.

Space Mull: Non-continuous blocks of wood are used to space units apart.

◦ 3/8", 1", 2", 3", 4" and 6" widths are available. Solid Space Mull: Solid continuous wood piece is used to reinforce the units and space them apart.

◦ 3/8", 1", 2", 3", 4" and 6" widths are available. LVL Mull: Laminated Veneered Lumber is used as a solid space mull.

◦ LVL is 1.7 to 1.9 times stronger than regular wood.

◦ 1" and 2" widths are available. Stud Pocket: An exterior mull cap is applied to the units with a space in between the units to allow for installation around an

existing structure in the opening.

Products IncludedClad Ultimate Replacement Casement

Clad Ultimate Replacement Awning

Clad Ultimate Replacement Pushout Casement

Clad Ultimate Replacement Pushout Awning

Clad Ultimate Replacement Casement/Awning Picture

NOTE: Multi-High Multi-Wide Assemblies with any side that exceed 72” in either direction will be shipped with a temporary blockingaround the entire perimeter of the assembly to provide support during shipping and handling.

Certified Mull Installation Methods: Jamb Screws

Tributary and Span:

Tributary Width - In the case of a vertical mull, this is equal to the sum of half of the width of each unit on each side of the mull. Inthe case of a horizontal mull, this is equal to the sum of half of the height of each unit on each side of the mull.

Span - The length of the mullion.

TributaryWidth

Span

TributaryWidth

TributaryWidth

TributaryWidth

Span

Ribbon Mull Stacked Mull

Mull-23 19972255Marvin Architectural Detail Manual

Ver 2018.1 2018-02-26

Page 24: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Section Details: Clad Ultimate Replacement Casement Mulling Types

Mull-24 19972255Marvin Architectural Detail Manual

Ver 2017.6 2017-12-18

Page 25: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Section Details: Clad Ultimate Replacement Casement Mulling Types (Continued)

Space Mulls and Solid Space Mulls areavailable in 3/8", 1", 2", 3", 4" and 6" widths.

Marvin provides interior mull trim for mullsup to 2".

Mull-25 19972255Marvin Architectural Detail Manual

Ver 2017.6 2017-12-18

Page 26: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Ultimate Replacement Casement Mulling-Standard Frame (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 722425262728293031 PG50 DP5032333435363738394041 DP 40 424344 DP3045464748495051 DP205253545556575859606162636465666768 PG406970717273747576777879 PG308081828384

Span

Tributary Width

Mull-26 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 27: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Ultimate Replacement Casement Mulling - 3/8" Mull Reinforcement (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 7224252627282930313233343536373839404142 DP50434445464748495051525354555657585960616263646566 DP4067686970717273747576 DP407778 DP 307980818283848586878889 DP 209091929394959697

Tributary Width

Span

Mull-27 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 28: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Ultimate Replacement Casement Mulling - 1" LVL (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 7224-31

323334353637383940 PG50 DP5041424344454647484950 DP4051525354 DP3055565758596061 DP2062636465666768697071727374 DP207576777879808182

Span

Tributary Width

Mull-28 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 29: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Ultimate Replacement Casement Mulling - 2" LVL (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 7224-31

323334353637383940414243444546 PG50 DP50474849505152535455565758 DP4059606162 DP30636465666768 DP20697071727374 DP3075767778798081828384 DP20858687888990919293

Tributary Width

Span

Mull-29 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 30: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Ultimate Replacement Casement Mulling - 3/8" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 7224252627282930313233 DP5034353637383940414243 DP4044454647 DP3048495051525354 DP205556575859606162636465666768697071

Tributary Width

Span

Mull-30 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 31: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Ultimate Replacement Casement Mulling - 1" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 7224252627282930313233343536373839 DP5040414243444546 DP4047484950 DP30515253545556 DP205758596061626364656667686970717273747576

Span

Tributary Width

Mull-31 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 32: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Ultimate Replacement Casement Mulling - 2" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 7224-31

32333435 DP50363738394041424344454647484950 DP405152535455 DP3056575859606162 DP206364656667686970717273747576777879808182

Tributary Width

Span

Mull-32 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 33: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Ultimate Replacement Casement Mulling - 3" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 7224-31

3233343536 DP50373839404142434445464748495051525354 DP405556575859 DP3060616263646566 DP206768697071727374757677787980818283848586878889

Tributary Width

Span

Mull-33 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 34: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Ultimate Replacement Casement Mulling - 4" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 7224-41

424344454647 DP504849505152535455565758 DP405960616263 DP30646566676869 DP207071727374757677787980818283848586878889909192939495

Tributary Width

Span

Mull-34 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 35: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Ultimate Replacement Casement Mulling - 6" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 7224-41

42434445464748495051 DP5052535455565758596061626364 DP4065666768 DP3069707172737475 DP2076777879808182838485868788899091929394959697

Tributary Width

Span

Mull-35 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 36: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Mull-36 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 37: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Direct Glaze Mull Types

Marvin offers a variety of mull options for many of the Marvin window and door projects. This document is a compilation of mullingoptions for the Clad Direct Glaze product.

Mull Types: Standard Mull: Two units mulled directly together without any reinforcement or space mulls between the frames.

3/8" Mull Reinforcement (MRF): A two-piece, thermally-broken aluminum reinforcement that allows for either factory or fieldassembly of the mullion.

Space Mull: Non-continuous blocks of wood are used to space units apart.

◦ 3/8", 1", 2", 3", 4" and 6" widths are available. Solid Space Mull: Solid continuous wood piece is used to reinforce the units and space them apart.

◦ 3/8", 1", 2", 3", 4" and 6" widths are available. LVL Mull: Laminated Veneered Lumber is used as a solid space mull.

◦ LVL is 1.7 to 1.9 times stronger than regular wood.

◦ 1" and 2" widths are available. Stud Pocket: An exterior mull cap is applied to the units with a space in between the units to allow for installation around an

existing structure in the opening.

Products IncludedClad Direct Glaze

IZ3 Clad Direct Glaze

Certified Mull Installation MethodsMasonry Clips

Jamb Screws

Structural Brackets

Tributary and Span:

Tributary Width - In the case of a vertical mull, this is equal to the sum of half of the width of each unit on each side of the mull. Inthe case of a horizontal mull, this is equal to the sum of half of the height of each unit on each side of the mull.

Span - The length of the mullion.

TributaryWidth

Span

TributaryWidth

TributaryWidth

TributaryWidth

Span

Ribbon Mull Stacked Mull

Mull-37 19972255Marvin Architectural Detail Manual

Ver 2017.6 2017-12-18

Page 38: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Section Details: Clad Direct Glaze Mulling Types

Mull-38 19972255Marvin Architectural Detail Manual

Ver 2017.6 2017-12-18

Page 39: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Section Details: Clad Ultimate Casement Mulling Types (Continued)

Space Mulls and Solid Space Mulls are avail-able in 3/8", 1", 2", 3", 4" and 6" widths.

Marvin provides interior mull trim for mulls upto 2".

Mull-39 19972255Marvin Architectural Detail Manual

Ver 2017.6 2017-12-18

Page 40: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

88

Clad Direct Glaze Mulling - Standard Frame (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86363840424446 DP6548505254565860626466 DP50687072 DP40747678 DP308082848688 DP 209092 PG50949698

100102 PG40104106108110 DP30112114 DP20116118120

Tributary Width

Span

Mull-40 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 41: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

6 88

Clad Direct Glaze Mulling - 3/8" Mull Reinforcement (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 83638404244464850 DP655254565860626466687072 DP507476788082 DP408486889092 DP30949698

100102104106 DP20108110112114116118120

Span

Tributary Width

Mull-41 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 42: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

88

Clad Direct Glaze Mulling - 1" LVL (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 8636384042444648505254 DP65565860626466687072 DP507476788082 DP408486889092 DP30949698

100102104106 DP20108110112114116118120

Span

Tributary Width

Mull-42 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 43: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Direct Glaze Mulling - 2" LVL (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88363840424446 DP6548505254565860626466687072 DP507476788082 DP40848688909294 DP309698

100102104106108110 DP20112114116118120

Span

Tributary Width

Mull-43 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 44: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

6 88

Clad Direct Glaze Mulling - 3/8" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 8363840424446485052 DP65545658606264666870 DP50727476 DP4078808284 DP308688909294 DP209698

100102104106108110112114116118120

Tributary Width

Span

Mull-44 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 45: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

6 88

Clad Direct Glaze Mulling - 1" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 8363840424446485052 DP6554565860626466687072 DP507476788082 DP4084868890 DP3092949698

100 DP20102104106108110112114116118120

Span

Tributary Width

Mull-45 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 46: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

88

Clad Direct Glaze Mulling - 2" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86363840424446485052 DP6554565860626466687072 DP507476788082 DP40848688909294 DP309698

100102104106108 DP20110112114116118120

Span

Tributary Width

Mull-46 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 47: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

8

Clad Direct Glaze Mulling - 3" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 836384042444648 DP65505254565860626466687072 DP507476788082 DP40848688909294 DP309698

100102104106108110 DP20112114116118120

Span

Tributary Width

Mull-47 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 48: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

88

Clad Direct Glaze Mulling - 4" and 6" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 863638404244464850 DP655254565860626466687072 DP507476788082 DP40848688909294 DP309698

100102104106108110112 DP20114116118120

Span

Tributary Width

Mull-48 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 49: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Direct Glaze Round Top Mull Types

Marvin offers a variety of mull options for many of the Marvin window and door projects. This document is a compilation of mullingoptions for the Clad Direct Glaze Round Top product.

Mull Types: Standard Mull: Two units mulled directly together without any reinforcement or space mulls between the frames.

3/8" Mull Reinforcement (MRF): A two-piece, thermally-broken aluminum reinforcement that allows for either factory or fieldassembly of the mullion.

Space Mull: Non-continuous blocks of wood are used to space units apart.

◦ 3/8", 1", 2", 3", 4" and 6" widths are available. Solid Space Mull: Solid continuous wood piece is used to reinforce the units and space them apart.

◦ 3/8", 1", 2", 3", 4" and 6" widths are available. LVL Mull: Laminated Veneered Lumber is used as a solid space mull.

◦ LVL is 1.7 to 1.9 times stronger than regular wood.

◦ 1" and 2" widths are available. Stud Pocket: An exterior mull cap is applied to the units with a space in between the units to allow for installation around an

existing structure in the opening.

Products IncludedClad Direct Glaze Round Top

4/4 Polygon

IZ3 Clad Direct Glaze Round Top

Certified Mull Installation MethodsMasonry Clips

Jamb Screws

Structural Brackets

Tributary and Span

Tributary Width - In the case of a vertical mull, this is equal to the sum of half of the width of each unit on each side of the mull. Inthe case of a horizontal mull, this is equal to the sum of half of the height of each unit on each side of the mull.

Span - The length of the mullion.

TributaryWidth

Span

TributaryWidth

TributaryWidth

TributaryWidth

Span

Ribbon Mull Stacked Mull

Mull-49 19972255Marvin Architectural Detail Manual

Ver 2018.1 2018-02-26

Page 50: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Section Details: Clad Direct Glaze Round Top Mulling Types

Mull-50 19972255Marvin Architectural Detail Manual

Ver 2017.6 2017-12-18

Page 51: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Section Details: Clad Direct Glaze Round Top Mulling Types (Continued)

Space Mulls and Solid Space Mulls are avail-able in 3/8", 1", 2", 3", 4" and 6" widths.

Marvin provides interior mull trim for mulls up to2".

Mull-51 19972255Marvin Architectural Detail Manual

Ver 2017.6 2017-12-18

Page 52: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

8

Clad Direct Glaze Round Top Mulling - Standard Frame (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 83638404244 DP6546485052545658 DP50606264 DP4066687072 DP307476788082 DP208486889092949698

100102104106108110112114116118120

Tributary Width

Span

Mull-52 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 53: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Direct Glaze Round Top Mulling - 3/8" Mull Reinforcement (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 8836384042444648 DP65505254565860626466687072 DP50747678808284 DP408688909294 DP309698100102104 DP20106108110112114116118120

Tributary Width

Span

Mull-53 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 54: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Direct Glaze Round Top Mulling - 1" LVL (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 8836384042444648 DP6550525456586062646668707274 DP50767880828486 DP408890929496 DP3098

100102104106 DP20108110112114116118120

Tributary Width

Mull-54 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 55: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Direct Glaze Round Top Mulling - 2" LVL (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 883638404244464850 DP655254565860626466687072 DP507476788082 DP4084868890929496 DP3098

100102104106108110112114 DP20116118120

Span

Tributary Width

Mull-55 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 56: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Direct Glaze Round Top Mulling - 3/8" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 883638404244464850 DP655254565860626466687072 DP507476788082 DP4084868890929496 DP3098

100102104106108110112114 DP20116118120

Span

Tributary Width

Mull-56 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 57: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

88

Clad Direct Glaze Round Top Mulling - 1" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 8636384042444648 DP655052545658606264666870 DP5072747678 DP4080828486 DP308890929496 DP2098

100102104106108110112114116118120

Span

Tributary Width

Mull-57 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 58: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

88

Clad Direct Glaze Round Top Mulling - 2" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 8636384042444648 DP6550525456586062646668707274 DP50767880828486 DP408890929496 DP3098

100102104106108 DP20110112114116118120

Tributary Width

Span

Mull-58 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 59: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Direct Glaze Round Top Mulling - 3" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 8836384042444648 DP65505254565860626466687072 DP 50747678808284 DP4086889092949698 DP30

100102104106108110112 DP20114116118120

Span

Tributary Width

Mull-59 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 60: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Direct Glaze Round Top Mulling - 4" and 6" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 8836384042444648 DP65505254565860626466687072 DP50747678808284 DP4086889092949698 DP30

100102104106108110 DP20112114116118120

Tributary Width

Span

Mull-60 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 61: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Narrow Frame (Contemporary) Direct Glaze Mull Types

Marvin offers a variety of mull options for many of the Marvin window and door projects. This document is a compilation of mullingoptions for the Clad Narrow Frame (Contemporary) Direct Glaze product.

Mull Types: Standard Mull: Two units mulled directly together without any reinforcement or space mulls between the frames.

3/8" Mull Reinforcement (MRF): A two-piece, thermally-broken aluminum reinforcement that allows for either factory or fieldassembly of the mullion.

Space Mull: Non-continuous blocks of wood are used to space units apart.

◦ 3/8", 1", 2", 3", 4" and 6" widths are available. Solid Space Mull: Solid continuous wood piece is used to reinforce the units and space them apart.

◦ 3/8", 1", 2", 3", 4" and 6" widths are available. LVL Mull: Laminated Veneered Lumber is used as a solid space mull.

◦ LVL is 1.7 to 1.9 times stronger than regular wood.

◦ 1" and 2" widths are available. Stud Pocket: An exterior mull cap is applied to the units with a space in between the units to allow for installation around an

existing structure in the opening.

Products IncludedClad Narrow Frame (Contemporary) Direct Glaze

NOTE: Multi-High Multi-Wide Assemblies with any side that exceed 72” in either direction will be shipped with a temporary blockingaround the entire perimeter of the assembly to provide support during shipping and handling.

Certified Mull Installation Methods Jamb Screws

Tributary and Span:

Tributary Width - In the case of a vertical mull, this is equal to the sum of half of the width of each unit on each side of the mull. Inthe case of a horizontal mull, this is equal to the sum of half of the height of each unit on each side of the mull.

Span - The length of the mullion.

TributaryWidth

Span

TributaryWidth

TributaryWidth

TributaryWidth

Span

Ribbon Mull Stacked Mull

Mull-61 19972255Marvin Architectural Detail Manual

Ver 2018.1 2018-02-26

Page 62: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Section Details: Clad Narrow Frame (Contemporary) Direct Glaze Mulling Types

Mull-62 19972255Marvin Architectural Detail Manual

Ver 2017.6 2017-12-18

Page 63: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Section Details: Clad Narrow Frame (Contemporary) Direct Glaze Mulling Types (Continued)

Space Mulls and Solid Space Mulls are avail-able in 3/8", 1", 2", 3", 4" and 6" widths.

Marvin provides interior mull trim for mulls upto 2".

Mull-63 19972255Marvin Architectural Detail Manual

Ver 2017.6 2017-12-18

Page 64: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

8-120

Clad Narrow Frame (Contemporary) Direct Glaze Mulling - Standard Frame (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 83638404244 PG50 DP504648505254 DP40565860 DP30626466 DP20687072747678808284 PG25868890929496

Span

Tributary Width

Mull-64 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 65: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Narrow Frame (Contemporary) Direct Glaze Mulling - 3/8" Mull Reinforcement (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88-1203638404244 DP5046485052545658606264666870 DP40727476 DP 30788082 DP 208486889092949698100102104106108110112114116118120

Tributary Width

Span

Mull-65 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 66: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Narrow Frame (Contemporary) Direct Glaze Mulling - 1" LVL (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88-1203638404244 DP504648505254565860 DP40626466 DP30687072 DP2074767880828486889092949698

Span

Tributary Width

Mull-66 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 67: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Narrow Frame (Contemporary) Direct Glaze Mulling - 2" LVL (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88-1203638404244 DP504648505254565860 DP40626466 DP30687072 DP2074767880828486889092949698

Span

Tributary Width

Mull-67 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 68: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Narrow Frame (Contemporary) Direct Glaze Mulling - 3/8" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88-1203638404244 DP50464850525456 DP40586062 DP30646668 DP20707274767880828486889092

Span

Tributary Width

Mull-68 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 69: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Narrow Frame (Contemporary) Direct Glaze Mulling - 1" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 '88-1203638404244 DP5046485052545658 DP40606264 DP30666870 DP2072747678808284868890929496

Span

Tributary Width

Mull-69 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 70: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Narrow Frame (Contemporary) Direct Glaze Mulling - 2" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88-120363840424446 DP50485052545658 DP40606264 DP3066687072 DP2074767880828486889092949698

100

Span

Tributary Width

Mull-70 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 71: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Narrow Frame (Contemporary) Direct Glaze Mulling - 3" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88-12036384042444648 DP5050525456586062 DP40646668 DP30707274 DP20767880828486889092949698

100102104

Span

Tributary Width

Mull-71 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 72: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Narrow Frame (Contemporary) Direct Glaze Mulling - 4" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88-12036384042444648 DP505052545658606264 DP40666870 DP30727476 DP207880828486889092949698

100102104106108

Span

Tributary Width

Mull-72 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 73: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Narrow Frame (Contemporary) Direct Glaze Mulling - 6" Solid Space Mull (Ribbon or Stacked Assembly)

20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88-120363840424446485052 DP505456586062646668 DP407072 DP3074767880 DP20828486889092949698

100102104106108110112114

Span

Tributary Width

Mull-73 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 74: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Mull-74 19972255Marvin Architectural Detail Manual

Page 75: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Ultimate Double Hung - NG 2.0 Mull Types

Marvin offers a variety of mull options for many of the Marvin window and door projects. This document is a compilation of mullingoptions for the Clad Ultimate Double Hung - Next Generation 2.0 product.

Mull Types: Standard Mull: Two units mulled directly together without any reinforcement or space mulls between the frames.

3/8" Mull Reinforcement (MRF): A two-piece, thermally-broken aluminum reinforcement that allows for either factory or fieldassembly of the mullion.

Space Mull: Non-continuous blocks of wood are used to space units apart.

◦ 3/8", 1", 2", 3", 4" and 6" widths are available. Solid Space Mull: Solid continuous wood piece is used to reinforce the units and space them apart.

◦ 3/8", 1", 2", 3", 4" and 6" widths are available. LVL Mull: Laminated Veneered Lumber is used as a solid space mull.

◦ LVL is 1.7 to 1.9 times stronger than regular wood.

◦ 1" and 2" widths are available. Stud Pocket: An exterior mull cap is applied to the units with a space in between the units to allow for installation around an

existing structure in the opening.

Products IncludedClad Ultimate Double Hung Next Generation 2.0

IZ3 Clad Ultimate Double Hung Next Generation 2.0

Certified Mull Installation MethodsMasonry Clips

Tributary and Span:

Tributary Width - In the case of a vertical mull, this is equal to the sum of half of the width of each unit on each side of the mull. Inthe case of a horizontal mull, this is equal to the sum of half of the height of each unit on each side of the mull.

Span - The length of the mullion.

TributaryWidth

Span

TributaryWidth

TributaryWidth

TributaryWidth

Span

Ribbon Mull Stacked Mull

Mull-75 19972255Marvin Architectural Detail Manual

Ver 2018.1 2018-02-26

Page 76: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Section Details: Clad Ultimate Double Hung - NG 2.0 Mulling Types

Mull-76 19972255Marvin Architectural Detail Manual

Ver 2017.6 2017-12-18

Page 77: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Section Details: Clad Ultimate Double Hung - NG 2.0 Mulling Types (Continued)

Mull-77 19972255Marvin Architectural Detail Manual

Ver 2017.6 2017-12-18

Page 78: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Section Details: Clad Ultimate Double Hung - NG 2.0 Mulling Types (Continued)

Space Mulls and Solid Space Mulls areavailable in 3/8", 1", 2", 3", 4" and 6" widths.

Marvin provides interior mull trim for mulls upto 2".

Mull-78 19972255Marvin Architectural Detail Manual

Ver 2017.6 2017-12-18

Page 79: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Section Details: Clad Ultimate Double Hung - NG 2.0 Mulling Types (Continued)

Space Mulls and Solid Space Mulls are also available in 1", 2", 3" and 4" widths.

Marvin provides interior mull trim for mulls up to 2".

Mull-79 19972255Marvin Architectural Detail Manual

Ver 2017.6 2017-12-18

Page 80: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Ultimate Double Hung - NG 2.0 Mulling - Standard Frame (Vertical) (Ribbon or Stacked Assembly)

CN 16 20 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60CN Frame OM 21.25 25.25 29.25 31.25 33.25 35.25 37.25 39.25 41.25 43.25 45.25 47.25 49.25 51.25 53.25 55.25 57.25 59.25 61.25 63.25 65.25

12 31.5

14 35.5

16 39.5 DP65

18 43.5

20 47.5 PG65

22 51.5 DP 50

24 55.5 DP40

26 59.5 DP30

28 63.5 DP20

30 67.5 PG50

32 71.5

34 75.5

36 79.5

38 83.5 PG 25

40 87.5

42 91.5

44 95.5

Tributary Width

Span

Mull-80 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 81: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Ultimate Double Hung - NG 2.0 Mulling - Standard Frame (Horizontal) (Ribbon or Stacked Assembly)

Frame OM 21.25 25.25 29.25 33.25 37.25 41.25 45.25 49.25 53.25 57.25 61.25 65.25 69.25 73.25

51.188

53.188

55.188

57.188

59.188

61.188

63.188

65.188

67.188 DP65

69.188

71.188

73.188

75.188

77.188

79.188

81.188

83.188

85.188

87.188

89.188

91.188

93.188 DP50

95.188

97.188

99.188

101.188

103.188

105.188

107.188

109.188

111.188

113.188

115.188

117.188

119.188

121.188

123.188

125.188

127.188 DP50 DP45

129.188

131.188

133.188

135.188

137.188

139.188

141.188

143.188

145.188

147.188

149.188

151.188

153.188

Span

Tributary Width (combined unit heights/2)

Mull-81 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 82: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Ultimate Double Hung - NG 2.0 Mulling - 1" LVL (Vertical) (Ribbon or Stacked Assembly)

CN 16 20 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60CN Frame OM 21.25 25.25 29.25 31.25 33.25 35.25 37.25 39.25 41.25 43.25 45.25 47.25 49.25 51.25 53.25 55.25 57.25 59.25 61.25 63.25 65.25

12 31.5

14 35.5

16 39.5

18 43.5

20 47.5 DP65

22 51.5

24 55.5

26 59.5

28 63.5

30 67.5

32 71.5

34 75.5 DP50

36 79.5

38 83.5 DP40

40 87.5 DP 30

42 91.5

44 95.5

46 99.5 DP 20

48 103.5

50 107.5

52 111.5

54 115.5

56 119.5

58 123.5

60 127.5

Span

Tributary Width

Mull-82 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 83: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Ultimate Double Hung - NG 2.0 Mulling - 2" LVL (Vertical) (Ribbon or Stacked Assembly)

CN 16 20 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60CN Frame OM 21.25 25.25 29.25 31.25 33.25 35.25 37.25 39.25 41.25 43.25 45.25 47.25 49.25 51.25 53.25 55.25 57.25 59.25 61.25 63.25 65.25

12 31.5

14 35.5

16 39.5

18 43.5

20 47.5 DP65

22 51.5

24 55.5

26 59.5

28 63.5

30 67.5

32 71.5

34 75.5

36 79.5 DP50

38 83.5

40 87.5

42 91.5 DP40

44 95.5

46 99.5

48 103.5

50 107.5 DP30

52 111.5

54 115.5

56 119.5 DP20

58 123.5

60 127.5

Tributary Width

Span

Mull-83 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 84: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Direct Glaze Mulling - 3/8" Mull Reinforcement (Ribbon or Stacked Assembly)

CN 16 20 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60CN Frame OM 21.25 25.25 29.25 31.25 33.25 35.25 37.25 39.25 41.25 43.25 45.25 47.25 49.25 51.25 53.25 55.25 57.25 59.25 61.25 63.25 65.25

12 31.5

14 35.5

16 39.5

18 43.5

20 47.5

22 51.5 DP65 DP65

24 55.5

26 59.5

28 63.5

30 67.5

32 71.5 DP50

34 75.5

36 79.5

38 83.5 DP40

40 87.5

42 91.5

44 95.5 DP30

46 99.5 DP20

48 103.5

50 107.5

52 111.5

54 115.5

56 119.5

58 123.5

60 127.5

Tributary Width

Span

Mull-84 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 85: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Ultimate Double Hung - NG 2.0 Mulling - 3/8" Solid Space Mull (Ribbon or Stacked Assembly)

CN 16 20 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60CN Frame OM 21.25 25.25 29.25 31.25 33.25 35.25 37.25 39.25 41.25 43.25 45.25 47.25 49.25 51.25 53.25 55.25 57.25 59.25 61.25 63.25 65.25

12 31.5

14 35.5

16 39.5 DP65

18 43.5

20 47.5

22 51.5 DP50

24 55.5

26 59.5 DP40

28 63.5 DP30

30 67.5

32 71.5

34 75.5 DP20

36 79.5

38 83.5

40 87.5

42 91.5

44 95.5

46 99.5

48 103.5

Tributary Width

Span

Mull-85 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 86: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Ultimate Double Hung - NG 2.0 Mulling - 1" Solid Space Mull (Ribbon or Stacked Assembly)

CN 16 20 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60CN Frame OM 21.25 25.25 29.25 31.25 33.25 35.25 37.25 39.25 41.25 43.25 45.25 47.25 49.25 51.25 53.25 55.25 57.25 59.25 61.25 63.25 65.25

12 31.5

14 35.5

16 39.5

18 43.5 DP65

20 47.5

22 51.5

24 55.5

26 59.5

28 63.5 DP50

30 67.5

32 71.5 DP40

34 75.5

36 79.5

38 83.5 DP30

40 87.5

42 91.5 DP20

44 95.5

46 99.5

48 103.5

50 107.5

52 111.5

54 115.5

56 119.5

58 123.5

60 127.5

Span

Tributary Width

Mull-86 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 87: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Ultimate Double Hung - NG 2.0 Mulling - 2" Solid Space Mull (Ribbon or Stacked Assembly)

CN 16 20 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60

CN Frame OM 21.25 25.25 29.25 31.25 33.25 35.25 37.25 39.25 41.25 43.25 45.25 47.25 49.25 51.25 53.25 55.25 57.25 59.25 61.25 63.25 65.25

12 31.5

14 35.5

16 39.5

18 43.5

20 47.5

22 51.5 DP65

24 55.5

26 59.5

28 63.5

30 67.5

32 71.5

34 75.5 DP50

36 79.5

38 83.5 DP40

40 87.5

42 91.5 DP30

44 95.5

46 99.5

48 103.5

50 107.5 DP20

52 111.5

54 115.5

56 119.5

58 123.5

60 127.5

Span

Tributary Width

Mull-87 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 88: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Ultimate Double Hung - NG 2.0 Mulling - 3" Solid Space Mull (Ribbon or Stacked Assembly)

CN 16 20 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60CN Frame OM 21.25 25.25 29.25 31.25 33.25 35.25 37.25 39.25 41.25 43.25 45.25 47.25 49.25 51.25 53.25 55.25 57.25 59.25 61.25 63.25 65.25

12 31.5

14 35.5

16 39.5

18 43.5

20 47.5 DP65

22 51.5

24 55.5

26 59.5

28 63.5

30 67.5

32 71.5

34 75.5 DP50

36 79.5

38 83.5

40 87.5 DP40

42 91.5

44 95.5

46 99.5 DP30

48 103.5

50 107.5

52 111.5 DP20

54 115.5

56 119.5

58 123.5

60 127.5Span

Tributary Width

Mull-88 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 89: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Ultimate Double Hung - NG 2.0 Mulling - 4" Solid Space Mull (Ribbon or Stacked Assembly)

CN 16 20 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60CN Frame OM 21.25 25.25 29.25 31.25 33.25 35.25 37.25 39.25 41.25 43.25 45.25 47.25 49.25 51.25 53.25 55.25 57.25 59.25 61.25 63.25 65.25

12 31.5

14 35.5

16 39.5

18 43.5

20 47.5 DP65

22 51.5

24 55.5

26 59.5

28 63.5

30 67.5

32 71.5

34 75.5 DP50

36 79.5

38 83.5

40 87.5 DP40

42 91.5

44 95.5

46 99.5 DP30

48 103.5

50 107.5

52 111.5 DP20

54 115.5

56 119.5

58 123.5

60 127.5Span

Tributary Width

Mull-89 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 90: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Ultimate Double Hung - NG 2.0 Mulling - 6" Solid Space Mull (Ribbon or Stacked Assembly)

CN 16 20 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60CN Frame OM 21.25 25.25 29.25 31.25 33.25 35.25 37.25 39.25 41.25 43.25 45.25 47.25 49.25 51.25 53.25 55.25 57.25 59.25 61.25 63.25 65.25

12 31.5

14 35.5

16 39.5

18 43.5

20 47.5 DP65

22 51.5

24 55.5

26 59.5

28 63.5

30 67.5

32 71.5

34 75.5

36 79.5 DP50

38 83.5

40 87.5

42 91.5

44 95.5 DP40

46 99.5

48 103.5

50 107.5

52 111.5 DP30

54 115.5

56 119.5 DP20

58 123.5

60 127.5

Span

Tributary Width

Mull-90 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 91: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Ultimate Glider Mull Types

Marvin offers a variety of mull options for many of the Marvin window and door projects. This document is a compilation of mullingoptions for the Clad Ultimate Glider product.

Mull Types: Standard Mull: Two units mulled directly together without any reinforcement or space mulls between the frames.

3/8" Mull Reinforcement (MRF): A two-piece, thermally-broken aluminum reinforcement that allows for either factory or fieldassembly of the mullion.

Space Mull: Non-continuous blocks of wood are used to space units apart.

◦ 3/8", 1", 2", 3", 4" and 6" widths are available. Solid Space Mull: Solid continuous wood piece is used to reinforce the units and space them apart.

◦ 3/8", 1", 2", 3", 4" and 6" widths are available. LVL Mull: Laminated Veneered Lumber is used as a solid space mull.

◦ LVL is 1.7 to 1.9 times stronger than regular wood.

◦ 1" and 2" widths are available. Stud Pocket: An exterior mull cap is applied to the units with a space in between the units to allow for installation of an existing

structure in the opening.

Products IncludedClad Ultimate Glider

Certified Mull Installation MethodsMasonry Clips

Jamb Screws

Structural Brackets

Tributary and Span:

Tributary Width - In the case of a vertical mull, this is equal to the sum of half of the width of each unit on each side of the mull. Inthe case of a horizontal mull, this is equal to the sum of half of the height of each unit on each side of the mull.

Span - The length of the mullion.

TributaryWidth

Span

TributaryWidth

TributaryWidth

TributaryWidth

Span

Ribbon Mull Stacked Mull

Mull-91 19972255Marvin Architectural Detail Manual

Ver 2018.1 2018-02-26

Page 92: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Section Details: Clad Ultimate Glider Mulling Types

Mull-92 19972255Marvin Architectural Detail Manual

Ver 2017.6 2017-12-18

Page 93: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Section Details: Clad Ultimate Glider Mulling Types (Continued)

Space Mulls and Solid Space Mulls are avail-able in 3/8", 1", 2", 3", 4" and 6" widths.

Marvin provides interior mull trim for mulls up to2".

Mull-93 19972255Marvin Architectural Detail Manual

Ver 2017.6 2017-12-18

Page 94: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Ultimate Glider Mulling - Standard Frame Vertical (Ribbon or Stacked Assembly)

CN 30 36 40 46 50 56 60 70 80 90 100CN Frame OM 35 1/2 41 1/2 47 1/2 53 1/2 59 1/2 65 1/2 71 1/2 83 1/2 95 1/2 107 1/2 119 1/2

30 35 1/2

36 41 1/2DP 50

40 47 1/2

46 53 1/2DP 40

50 59 1/2DP 30

56 65 1/2 DP 20

60 71 1/2

Span

Tributary Width

Mull-94 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 95: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Ultimate Glider Mulling - 3/8" MRF, 1" LVL, 2" LVL (Vertical) (Ribbon or Stacked Assembly)

CN 30 36 40 46 50 56 60 70 80 90 100CN Frame OM 35 1/2 41 1/2 47 1/2 53 1/2 59 1/2 65 1/2 71 1/2 83 1/2 95 1/2 107 1/2 119 1/2

30 35 1/2

36 41 1/2

40 47 1/2

46 53 1/2DP 50

50 59 1/2

56 65 1/2

60 71 1/2

Span

Tributary Width

Mull-95 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 96: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Ultimate Glider Mulling - 3/8" Solid Space Mull (Vertical) (Ribbon or Stacked Assembly)

CN 30 36 40 46 50 56 60 70 80 90 100CN Frame OM 35 1/2 41 1/2 47 1/2 53 1/2 59 1/2 65 1/2 71 1/2 83 1/2 95 1/2 107 1/2 119 1/2

30 35 1/2

36 41 1/2 DP 50

40 47 1/2

46 53 1/2

50 59 1/2DP 40

56 65 1/2DP 30

60 71 1/2DP 20

Tributary Width

Span

Mull-96 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 97: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Ultimate Glider Mulling - 1" Solid Space Mull (Vertical) (Ribbon or Stacked Assembly)

CN 30 36 40 46 50 56 60 70 80 90 100CN Frame OM 35 1/2 41 1/2 47 1/2 53 1/2 59 1/2 65 1/2 71 1/2 83 1/2 95 1/2 107 1/2 119 1/2

30 35 1/2

36 41 1/2

40 47 1/2 DP 50

46 53 1/2

50 59 1/2

56 65 1/2

60 71 1/2DP 40 DP 30

Span

Tributary Width

Mull-97 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 98: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Ultimate Glider Mulling - 1" and 2" LVL (Horizontal) (Ribbon or Stacked Assembly)

CN 30 36 40 46 50 56 60CN Frame OM 35 1/2 41 1/2 47 1/2 53 1/2 59 1/2 65 1/2 71 1/2

30 35 1/2

36 41 1/2

40 47 1/2

46 53 1/2DP 50

50 59 1/2

56 65 1/2

60 71 1/2

66 77 1/2 DP 40

70 83 1/2

76 89 1/2 DP 30

80 95 1/2

86 101 1/2

90 107 1/2DP 20

96 113 1/2

Tributary Width

Span

Mull-98 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 99: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Ultimate Glider Mulling - Solid Space Mull (2", 3", 4" and 6") (Ribbon or Stacked Assembly)

CN 30 36 40 46 50 56 60 70 80 90 100CN Frame OM 35 1/2 41 1/2 47 1/2 53 1/2 59 1/2 65 1/2 71 1/2 83 1/2 95 1/2 107 1/2 119 1/2

30 35 1/2

36 41 1/2

40 47 1/2DP 50

46 53 1/2

50 59 1/2

56 65 1/2

60 71 1/2

Tributary Width

Span

Mull-99 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 100: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Mull-100 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 101: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

General Mulling Information

Multi-High, Multi-Wide Mulling

Marvin offers a variety of mull options for many of the Marvin window and door projects. Some mulls can be done in the factory.Others would need to be done in the field. Some mulls create a certified assembly according to third-party testing.

Marvin Mull Options:

Marvin-Supplied Standard Mull: Two units mulled directly together without any reinforcement or space mulls between the frames.

3/8" Mull Reinforcement (MRF): A two-piece, thermally-broken aluminum reinforcement that allows for either factory or fieldassembly of the mullion.

Solid Space Mull: Solid continuous wood piece is used to reinforce the units and space them apart.

◦ 3/8", 1", 2", 3", 4" and 6" widths are available. LVL Mull Reinforcement: Laminated Veneered Lumber is used as a solid space mull.

◦ LVL is 1.7 to 1.9 times stronger than regular wood.

◦ 1" and 2" widths are available from Marvin. Space Mull: Non-continuous blocks of wood are used to space units apart.

◦ 3/8", 1", 2", 3", 4" and 6" widths are available. Stud Pocket: An exterior mull cap is applied to the units with a space in between the units to allow for installation of an existing

structure in the opening.

Field Supplied and Applied Tube Mull: Tube aluminum or steel used to reinforce mulled assemblies.

Flat Mull: Flat Steel or Aluminum used to reinforce mulled assemblies.

NOTE: Multi-High Multi-Wide Assemblies with any side that exceed 72” in either direction will be shipped with a temporary blockingaround the entire perimeter of the assembly to provide support during shipping and handling.

Certified Mull Installation MethodsMasonry Clips

Jamb Screws

Structural Brackets

Anchoring Special considerations need to be made when installing mulled assemblies. Mullions create point loads that need to be

transferred to the rough opening. For Marvin standard, MRF, LVL, and space mulls, the ends of the mull need to be fastened oneach side of the splice with either jamb screws or brackets. Aluminum, steel and other structural mulls need to be anchoreddirectly to the rough opening or building structure.

Tributary and Span:

Tributary Width - The area supported by the mullion. In the case of a vertical mull, this is equal to the sum of half of the width of eachunit on each side of the mull.

Span - The length of the mullion

TributaryWidth

SpanTributary

Width

Span

Reinforcement

Rei

nfor

cem

ent

2 Wide 2 High 2 Wide 2 High

Multi-Wide Multi-High Mull

Mull-101 19972255Marvin Architectural Detail Manual

Ver 2018.1 2018-02-26

Page 102: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

General Mulling Information

Multi-High Multi-Wide (Full Frame 3/8" Mull Reinforcement)

Mullion Performance Charts

In accordance with the Intern

24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88485052 DP 50545658 DP 40606264 PG 6566 DP 3068707274 PG 40 DP 2576788082 DP 2084868890 PG 5092949698

100102104106108 PG 25110112114116118120

Span

Tributary Width

Mull-102 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 103: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

General Mulling Information

Multi-High Multi-Wide (Narrow Frame 3/8" Mull Reinforcement)

24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 884850 DP 4052545658 DP 5060 DP 206264 DP 3066687072747678 DP 408082848688 DP 20909294

Tributary Width

Span

Mull-103 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 104: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

General Mulling Information

Multi-High Multi-Wide (Full Frame 1" LVL)

24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 884850 DP 505254 DP 405658 DP 656062 DP 306466687072747678 DP 5080 DP 40 DP 30 DP 20828486889092949698

100102104106108110112114116118120

Span

Tributary Width

Mull-104 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 105: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

General Mulling Information

Multi-High Multi-Wide (Full Frame 2" LVL)

24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88485052545658 DP 65606264666870727476788082 DP 50848688 DP 4090929496 DP 3098

100102104106 DP 20108110112114116118120

Span

Tributary Width

Mull-105 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 106: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

General Mulling Information

Mull-106 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 107: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Ultimate Inswing French Door Mull Types

Marvin offers a variety of mull options for many of the Marvin window and door projects. This document is a compilation of mullingoptions for the Clad Ultimate Inswing French Door product.

Mull Types: Standard Mull: Two units mulled directly together without any reinforcement or space mulls between the frames.

2" LVL Mull: Laminated Veneered Lumber is used as a solid space mull.

Products IncludedClad Ultimate Inswing French Door

IZ3 Clad Ultimate Inswing French Door

Certified Mull Installation MethodsMasonry Clips

Jamb Screws

Structural Brackets

Tributary and Span:

Tributary Width - In the case of a vertical mull, this is equal to the sum of half of the width of each unit on each side of the mull. Inthe case of a horizontal mull, this is equal to the sum of half of the height of each unit on each side of the mull.

Span - The length of the mullion.

TributaryWidth

Span

Mull-107 19972255Marvin Architectural Detail Manual

Ver 2018.1 2018-02-26

Page 108: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Section Details: Clad Ultimate Inswing French Door Mulling Types

Mull-108 19972255Marvin Architectural Detail Manual

Ver 2017.6 2017-12-18

Page 109: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Section Details: Clad Ultimate Inswing French Door Mulling Types (Continued)

Mull-109 19972255Marvin Architectural Detail Manual

Ver 2017.6 2017-12-18

Page 110: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Ultimate Inswing French Door Mulling - All Mull Types

NOTE: Includes CUIFD with transoms of 1 frame and 1 sash (French Door Transoms, CUDH NG 2.0 Transoms, Clad Direct GlazeTransoms or Clad Ultimate Casement Transoms.

48 50 52 54 56 58 60 62.75

60.625 DP 50

72.625

PG 40

84.625

96.625 DP 30

110.719

DP 20

125.813

Span

Tributary Width

Mull-110 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 111: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Ultimate Outswing French Door Mull Types

Marvin offers a variety of mull options for many of the Marvin window and door projects. This document is a compilation of mullingoptions for the Clad Ultimate Outswing French Door product.

Mull Types: Standard Mull: Two units mulled directly together without any reinforcement or space mulls between the frames.

2" LVL Mull: Laminated Veneered Lumber is used as a solid space mull.

Products IncludedClad Ultimate Outswing French Door

IZ3 Clad Ultimate Outswing French Door

Certified Mull Installation MethodsMasonry Clips

Jamb Screws

Structural Brackets

Tributary and Span:

Tributary Width - In the case of a vertical mull, this is equal to the sum of half of the width of each unit on each side of the mull. Inthe case of a horizontal mull, this is equal to the sum of half of the height of each unit on each side of the mull.

Span - The length of the mullion.

TributaryWidth

Span

Mull-111 19972255Marvin Architectural Detail Manual

Ver 2018.1 2018-02-26

Page 112: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Section Details: Clad Ultimate Outswing French Door Mulling Types

Mull-112 19972255Marvin Architectural Detail Manual

Ver 2017.6 2017-12-18

Page 113: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Section Details: Clad Ultimate Outswing French Door Mulling Types (Continued)

Mull-113 19972255Marvin Architectural Detail Manual

Ver 2017.6 2017-12-18

Page 114: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Ultimate Outswing French Door Mulling - All Mull Types

NOTE: Includes CUOFD with transoms of 1 frame and 1 sash (French Door Transoms, CUDH NG 2.0 Transoms, Clad Direct GlazeTransoms or Clad Ultimate Casement Transoms.

48 50 52 54 56 58 60 62.75

60.625 DP 50

72.625

PG 40

84.625

96.625 DP 30

110.719

DP 20

125.813

Span

Tributary Width

Mull-114 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 115: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Ultimate Sliding French Door Mull Types

Marvin offers a variety of mull options for many of the Marvin window and door projects. This document is a compilation of mullingoptions for the Clad Ultimate Sliding French Door product.

Mull Types: Standard Mull: Two units mulled directly together without any reinforcement or space mulls between the frames.

2" LVL Mull: Laminated Veneered Lumber is used as a solid space mull.

Products IncludedClad Ultimate Sliding French Door

IZ3 Clad Ultimate Sliding French Door

Certified Mull Installation MethodsMasonry Clips

Jamb Screws

Structural Brackets

Tributary and Span:

Tributary Width - In the case of a vertical mull, this is equal to the sum of half of the width of each unit on each side of the mull. Inthe case of a horizontal mull, this is equal to the sum of half of the height of each unit on each side of the mull.

Span - The length of the mullion.

TributaryWidth

Span

Mull-115 19972255Marvin Architectural Detail Manual

Ver 2018.1 2018-02-26

Page 116: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Section Details: Clad Ultimate Sliding French Door Mulling Types

Mull-116 19972255Marvin Architectural Detail Manual

Ver 2017.6 2017-12-18

Page 117: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Section Details: Clad Ultimate Sliding French Door Mulling Types (Continued)

Mull-117 19972255Marvin Architectural Detail Manual

Ver 2017.6 2017-12-18

Page 118: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Ultimate Sliding French Door Mulling - All Mull Types

NOTE: Includes CUSFD with transoms of 1 frame and 1 sash (French Door Transoms, CUDH NG 2.0 Transoms, Clad Direct GlazeTransoms or Clad Ultimate Casement Transoms.

48 50 52 54 56 58 60 62.75

60.625 DP 50

72.625

PG 40

84.625

96.625 DP 30

110.719

DP 20

125.813

Span

Tributary Width

Mull-118 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25

Page 119: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Sliding Patio Door Mull Types

Marvin offers a variety of mull options for many of the Marvin window and door projects. This document is a compilation of mullingoptions for the Clad Sliding Patio Door product.

Mull Types: Standard Mull: Two units mulled directly together without any reinforcement or space mulls between the frames.

2" LVL Mull: Laminated Veneered Lumber is used as a solid space mull.

Products IncludedClad Sliding Patio Door

Certified Mull Installation MethodsMasonry Clips

Jamb Screws

Structural Brackets

Tributary and Span:

Tributary Width - In the case of a vertical mull, this is equal to the sum of half of the width of each unit on each side of the mull. Inthe case of a horizontal mull, this is equal to the sum of half of the height of each unit on each side of the mull.

Span - The length of the mullion.

TributaryWidth

Span

Mull-119 19972255Marvin Architectural Detail Manual

Ver 2018.1 2018-02-26

Page 120: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Section Details: Clad Sliding Patio Door Mulling Types

Mull-120 19972255Marvin Architectural Detail Manual

Ver 2017.6 2017-12-18

Page 121: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Section Details: Clad Sliding Patio Door Mulling Types (Continued)

Mull-121 19972255Marvin Architectural Detail Manual

Ver 2017.6 2017-12-18

Page 122: General Mulling Information - Marvin ADM Mulls All.pdf · General Mulling Information Mull-4 19972255 Marvin Architectural Detail Manual Ver 2017.6 2017-12-18 General Mull Information

Clad Mulling

Clad Sliding Patio Door Mulling - All Mull Types

NOTE: Includes CSPD with transoms of 1 frame and 1 sash (French Door Transoms, CUDH NG 2.0 Transoms, Clad Direct GlazeTransoms or Clad Ultimate Casement Transoms.

48 50 52 54 56 58 60 62.75

60.625 DP 50

72.625

PG 40

84.625

96.625 DP 30

110.719

DP 20

125.813

Span

Tributary Width

Mull-122 19972255Marvin Architectural Detail Manual

Ver 2018.3 2018-06-25