82
General Catalogue 01. 2010

General Catalogue 2010

  • Upload
    rps-spa

  • View
    221

  • Download
    3

Embed Size (px)

DESCRIPTION

General Catalogue 2010

Citation preview

General Catalogue01. 2010

CATG

ENX0

110R

UGB

I

n th

e in

tere

sts

of p

rodu

ct im

prov

emen

t Rie

llo U

PS re

serv

es th

e rig

ht to

cha

nge

spec

ifica

tions

with

out n

otice

.

1

06 iPlug08 iDialog10 Win Dialog Plus12 Dialog Vision16 Premium Pro20 Premium Dual24 Dialog Dual28 Power Dialog 332 Multi Plus38 Multi Dialog MDT40 Master Plus48 Master Plus HIP52 Master Plus Industrial54 Master Plus 400 Hz56 Multi Switch58 Master Switch

Product Range

67 Powershield3

68 Power Net Guard69 Netman 101 Plus69 Netman 202 Plus70 Environmental Sensors70 Multicom 301/30271 Multicom 351/35271 Multicom 36271 Multicom 37272 Multicom 38272 Multi I/O72 I/O73 Multicom 40173 Kit for AS400 and i-series73 Multi Panel74 Connectivity: some solutions76 Compatibility Table

Connectivity

Services and Consultancy

By-pass Accessories

Standby Power Systems

78

77

62-6364 Sinux Inverters

Index

2

Riello UPS & Riello Elettronica

The main activities of RIELLO UPS are the research & development, design, manufacture, sale and service of Uninterruptible Power Supplies. These are used throughout the world to provide a guaranteed continuous supply of electrical energy to information technology systems, used within data centres and IT network operations within finance, transportation, industrial manufacturing, health and other critical sectors.Riello UPS has become a market leader in Europe and one of the World’s top five UPS manufacturers thanks to its focus on customer service, investments and experience. The Riello UPS product range includes solutions for powering the smallest desktop PCs or the latest super computers used within the most advanced data centre operations. Riello UPS can be found within banks, hospitals, airports and almost wherever a continuous electrical supply is critical. The UPS range includes single-phase and three-phase systems from 400VA up to 6.4MVA.

POWER QUALITY: CONTINUOUS ENERGYRiello UPS is committed to the supply of power solutions providing the highest level of efficiency, resilience and power quality on a global basis and for any application requiring continuous energy.

Established in 1986, Riello Elettronica is the parent company of a group of businesses operating within the Energy, and Automation and Security sectors. The company started manufacturing switching power supplies for information technology applications, before moving into the manufacture of Uninterruptible Power Supplies (UPS). In 1995 Riello Elettronica became a holding company with operations within civil and industrial electronics, plant engineering and information technology sectors, security and intelligent home systems, and its established UPS manufacturing business. Also part of this strategic development was the restructuring of its energy-related activities under a new organisation – Riello UPS.

Power Quality can be defined using two parameters:• Continuity - the availability of the power supply and its resilience• Waveform - the purity of the waveform in terms of its voltage and

current characteristicsThe Riello UPS product range is extensive, ensuring the availability of a power solution for any critical application requiring a single UPS or turn-key solution combining UPS, Static Transfer Switches, Inverters and other power products.

BUSINESS CONTINUITY AND CONNECTIVITYRIELLO UPS products represent ‘state-of-the-art’ developments within the energy management sector. There are currently 15 UPS product lines offering various operating topologies and configurations. Their principle application is within ‘Business Continuity’. Here Riello UPS guarantee the power quality supplied to critical applications, to allow them to function during partial or complete mains power supply failures. This quality concept is central to the Riello UPS corporate culture and every aspect (including products, personnel and services) revolves around this. Whilst product quality is a prerequisite, it is the human element that can also differentiate a company and deliver true value added. All Riello UPS personnel are actively encouraged, wherever they are within the organisation, to contribute towards improvements, whether they relate to products, systems or services. Teamwork is an essential aspect of this approach to quality and the certifications received from external bodies and customer endorsements are proof that Riello UPS is achieving its quality objectives.

3

Phase Power (KVA)

0,5 0,75 1 2 4 5 10 20 40 80 100 200 400 800

iPlug 1/1

iDialog 1/1

Dialog Vision 1/1

Premium Pro 1/1

Premium Dual 1/1

Dialog Dual1/1

3/1

Power Dialog 31/1

3/1

Multi Plus

1/1

3/1

3/3

Multi Dialog MDT 3/3

Master Plus3/3

3/1

Master Plus HIP 3/3

Master Plus Industrial 3/1

Master Plus 400 Hz 3/3

0,6-0,8

0,4-1,6

0,5-3

0,7-3

1-3

3,3-10

10-800

10-100

100-400

10-20

10-20

10-40

30-80

30-120

60-80

100-120

5-6

6,5-10

6,5-10

UPS Range

INNOVATION. THE PRIMARY OBJECTIVERiello UPS operates two research centres in Italy: one in Legnago (near Verona) for transformerless UPS up to 120kVA and the other in Cormano (Milan) for transformer-based systems up to 800KVA and custom-design products. A separate design team also operates from the Milan facility and is dedicated to the research and development of inverter photovoltaic applications. The research centres are separated into three distinct areas of activity within the new product development process:• Projects: concerned with concept design• Experimental: for concept testing, analysis and evaluation within

laboratory conditions• Testing: prototype validationEach phase is part of a continuous innovation process that is designed to deliver world beating power solutions to solve today’s energy problems.

EUROPEAN PRODUCTS - AN INTERNATIONAL COMPANYIn a world where many companies are choosing to locate manufacturing based on labour costs, often sacrificing product and service quality, Riello UPS continues to invest in a European production system. This creates two positive benefits: the Riello UPS product range is highly reliable, benefiting from an approach to research & development, manufacturing, distribution and service that it totally integrated. Secondly, the process strengthens a culture of ‘continuous improvement”, providing timely feedback, even during manufacture and assembly. The end result is a superior product range that enhances the reputation that Riello UPS enjoys for efficiency, resilience and quality.

4

ECO LINE

SUSTAINABLE ENERGY fOR OUR fUTUREWith a concern for the environment, Riello UPS has taken an active role in developing a culture of sustainable development and reduced energy consumption. It has established a number of environmentally friendly projects and made substantial R&D investments into new technologies. These are targeted at the generation of ‘clean energy’ products and the development of even more efficient UPS in the future. This is a social commitment, which will benefit the present and have a positive impact on the future; the Riello UPS Environmental Management System is accredited to ISO14001 as testament to the Riello commitment to the environment.

RIELLO UPS AND ENVIRONMENTRiello UPS has a company-wide initiative to become the most environmentally friendly power protection company in Europe. As a company, Riello UPS is a major contributor to the European Commission – Code of Conduct on Energy Efficiency and Quality of AC Uninterruptible Power Supplies - and the first European manufacturer to rate its products for ECO Energy Level effciency.The European Commission Code of Conduct is a document signed by the major UPS manufacturers in Europe which outlines the efficiency levels to reach for specific size bands from 10-800kVA, from 25% to 100% loading. For a 200kVA UPS at full load the benchmark is 93% in full on-line mode.In addition to making its products achieve the highest possible operating efficiencies, Riello UPS has also focused its research and development efforts on other aspects that impact the environment.• Adaptive battery management to lengthen the period between battery

replacement and disposal programmes and reduce the wear on other consumables such as fans and capacitors.

• Low Total Harmonic Distortion on the input side (THDi) of (3%) to reduce the impact on upstream equipment and a high input power factor (0.99).

• Adaptive “Smart Mode” operation in which the UPS selects a mode of operation that matches the electrical characteristics of the mains power supply to the power protection performance required by the load.

ECO LINERiello UPS exceeds the specifications of the European Code of Conduct (on Energy Efficiency and Quality of Uninterruptible Power Supplies) and has also introduced energy savings products below 3kVA – known as the ‘ECO LINE’. Again the focus is on energy efficiency and savings – for instance by ensuring that power is not consumed by the UPS when it is connected to the mains power supply, with no load or output voltage.

Riello UPS and Environment

5

1 2 3 4 5 6

ECO Energy Levels

ECO ENERGY LEVELSRiello UPS powers some of the most critical data centres in use today. Within such environments, energy management is critical. Running costs must be minimised without compromising resilience and the capabilities to withstand a mains power supply interruption and disruption of service. Efficiency levels must be at the highest possible levels to reduce the stress on critical power supplies and minimise the effect on local ambients.The ECO Energy Level ratings used within this guide identify how Riello UPS products comply with the European Commission Code of Conduct. There are six levels, with level 6 being the highest that can be achieved by a UPS in full on-line mode as defined by VFI-SS-111. ‘Smart Mode’ is an intelligent economy mode at which even higher levels of efficiency can be achieved.The Riello UPS ECO Energy Levels rating system demonstrates the Riello commitment to the environment and promotes an open-way for users to identify potential cost-savings from reduced operational energy usage, lower heat outputs and carbon-footprints. Riello UPS is the first UPS manufacture to differentiate its products using the ECO Energy Levels guide. The rating system has been applied from 3kVA (below the 10kVA threshold limit applied by the European Commission) because Riello UPS is committed to the environmental impact of its entire product range.

Riello UPS ECO Energy Levels is more than a concept. As well as playing a part in the wider corporate initiative the system demonstrates how Riello UPS can achieve capital payment periods that are up to half the industry standard, and with a reduced ‘carbon-footprint’ - both important benefits in an environmentally and energy challenged world.On the Riello UPS website (www.riello-ups.com) is an Energy Savings Calculator that can be used to show the energy and money saved using Riello ECO Energy level 6 products. The calculator also shows the reductions in CO

2 available per model.

Energy Level Comparison betweenUPS efficiency with CoC

“Smart Mode”availability

ECO 6 Higher Yes

ECO 5 Higher -

ECO 4 Matches Yes

ECO 3 Matches -

ECO 2 Lower Yes

ECO 1 Lower -

6

iPlu

g 6

00-8

00 V

A

6

ECO LINE

iPlug600-800 VAsingle-phase

PERSONAL COMPUTERS

The iPlug series is the ideal solution for household, and small home office systems. Its compact size and versatility - push-button operation, LED status panel and user-replaceable batteries - make iPlug easy to install within a domestic environment to protect systems from surges and blackouts. When mains power fails the load is powered by the inverter and built-in battery. PowerShield3 UPS monitoring and control software (available for download from www.riello-ups.com) can be used for an orderly unattended shutdown of IT systems.

LOAD CONfIGURATOR

fEATURES• ECO LINE energy efficient product• Compact, ergonomic design• 5 sockets with battery backup• 3 sockets with surge protection only• Cold start capability to power up the UPS without mains power• User replaceable batteries• USB interface for remote monitoring• Power cable included• Protection from short-circuits• Auto restart - when the mains returns after battery exhaustion• GS/Nemko safety marking• Available with French (2P+E), English, Schuko and Italian outlets.

ADVANCED COMMUNICATION• PowerShield3 supervision and shut-down software for Windows 7,

2008, Vista, 2003, XP, Linux, Mac OS X and Sun Solaris operating systems

• Plug and Play function.

2 YEAR WARRANTY

Load type Power (VA)*

Personal computer 250

LCD Monitor 70

15” Monitor 150

Scanner, printer 200

Modem, TV, DVD reader, PlayStation, Hi-Fi, Phone, Fax 50

Laser printer** 200

*Average estimated value. **Use the iPLUG filtered power output.

7

iPlu

g 6

00-8

00 V

A

7

iPlug 600 iPlug 800

600VA/360W 800VA/480W

iPlug 600 - iPlug 800

MODELS

POWER

INPUT

Rated voltage 220-240 Vac

Voltage range 230 Vac (+20/-25%)

Frequency 50/60 Hz with auto sensing

OUTPUT

Voltage on mains operation 230 Vac (+20/-25%)

Voltage on battery operation 230 Vac (+/- 10%)

Frequency on battery operation 50 or 60 Hz (+/- 1%)

BATTERIES

Type VRLA AGM Maintenance-free lead-acid

Recharge time 6-8 h

ENVIRONMENTAL

Net weight (kg) 3.7 4.1

Gross weight (kg) 4 4.4

Dimensions (hwd) (mm) 99 x 175 x 313

Packaging dimensions (hwd) (mm) 260 x 380 x 140

Communication USB

Compliance EN 62040-1-1 and Directive 2006/95/EC; EN 62040-3EN 62040-2 and Directive 2004/108 EC

Marks CE; GS/NEMKO on Schuko version

Operating temperature 0°C / +40°C

Colour Black

Altitude and relative humidity 6000 meters max. elevation, <95% non condensing

Accessories provided 1 input supply cable, user guide

TECHNICAL DETAILS

IEC OUTLETS WITH UPS PROTECTION

USB COMMUNICATION PORTSAFETY FUSE

SOCKETS WITH UPS PROTECTION(NO BREAK IN POWER IF MAINS FAILS)

FILTERED SOCKETS: OVERVOLTAGE PROTECTION ONLY

AVAILABLE SOCKETS

FRENCH SOCKETCEE 7/5

SCHUKO SOCKETCEE 7/7P

ITALIAN SOCKETCEI 23/16

BRITISH SOCKETBS1363A

Rear detail

LED detail

8

iDia

log

400

-160

0 VA

ECO LINE

iDialog400-1600 VA

SMALL COMPUTERSNETWORK

PERSONAL COMPUTERS

single-phase

• Suitable for installation on PCs running Windows 7, 2008, Vista, 2003, Xp, Linux, Mac OSX and Sun Solaris operating system.

• Compact dimensions and ergonomic design: iDialog can be placed on a desk top or other convenient location, with easy to access connections and informative front panel.

• Silent running: iDialog can be used to protect other senstiive electronic devices including Home Cinemas, CD Writers, DVD players, Satellite and Digital Terrestrial receivers.

2 YEAR WARRANTY

The iDialog UPS has been designed to protect PCs and critical peripherals in home and small office environments. iDialog is easy to install and provides powerful, economic protection for:• IT equipment including PCs, Media Centers, PoE, VoIP and other such

peripherals.• TVs, Home Cinemas, Satellite and Digital Terrestrial receivers, DVD

readers and writers.• Modems and xDSL routers.• Small household appliances.

CHARACTERISTICS• Maximum power protection with PowerShield3 UPS monitoring and

shutdown software available for free download from our website www.riello-ups.com

9

iDia

log

400

-160

0 VA

ID 40 - ID 60 - ID 80 ID 120 - ID 160

ID 40 ID 60 ID 80 ID 120 ID 160

400VA/240W 600VA/360W 800VA/480W 1100VA/660W 1600VA/960W

MODELS

POWER

INPUT

Rated voltage 220-240 Vac

Input voltage tolerance 230 Vac (+20/-25%)

Frequency 50/60 Hz with auto sensing

OUTPUT

Voltage during mains operation 230 Vac (+20/-25%)

Voltage during battery operation 230 Vac (+/- 10%)

Frequency during battery operation 50 or 60 Hz (+/- 1%)

BATTERIES

Type VRLA AGM Maintenance-free lead-acid

Recharge time 6-8 h

ENVIRONMENTAL

Net weight (kg) 3.2 3.4 6.6 7

Gross weight (kg) 3.7 4.1 8.1 8.6

Dimensions (hwd) (mm) 192 x 90 x 232 275 x 97 x 315

Packaging dimensions (hwd) (mm) 278 x 300 x 138 370 x 400 x 170

Communication USB

Output sockets 4 IEC 6 IEC

Compliance EN 62040-1-1 and Directive 2006/95/EC; EN 62040-3EN 62040-2 and Directive 2004/108 EC

Marks CE; GS/Nemko

Operating temperature 0°C / +40°C

Colour Black

Altitude and relative humidity 6000 meters max. elevation, < 95% non condensing

Accessories provided 2 output supply cables, 1 USB cable, user guide

SOCKETS WITH UPS PROTECTION(NO BREAK IN POWER IF MAINS FAILS)

FILTERED SOCKETS: OVERVOLTAGEPROTECTION ONLY

USB COMMUNICATION PORT

MAINS INPUT

TECHNICAL DETAILS

SAFETYFUSE

RS232 SERIALPORT

LED detail

10

Win

Dia

log

Plus

400

-800

VA

Win Dialog Plus400-800 VA

The WIN DIALOG PLUS series includes the 400-600-800VA models and uses digital technology. The load is powered from the mains through an AVR to stabilise brownout, sag and surge voltages, and EMI filters to suppress spikes and transients. When the mains fails, the load is powered by the inverter with a pseudo sinewave to provide sufficient runtime for computer system shutdown using the PowerShield3 software supplied as standard.

CHARACTERISTICS• Mains power supply stabilisation and filtering (technology with AVR and filters for atmospheric disturbance suppression)• Cold Start capability: the UPS can power up without a mains supply present• High reliability with built-in battery test feature• Supplied with 2 output cables

ADVANCED COMMUNICATION• Advanced, multi-platform communication for all operating systems and

network environments: PowerShield3 monitoring and shut-down software included, for Windows 7, 2008, Vista, 2003, Xp, Linux, Mac OSX and Sun Solaris operating system.

• Advanced communication (standard USB interface).

2 YEAR WARRANTY

single-phase

SMALL COMPUTERSNETWORK

PERSONAL COMPUTERS

11

Win

Dia

log

Plus

400

-800

VA

WP 40UWP 60UWP 80U

WP 40U WP 60U WP 80U

400VA/240W 600VA/360W 800VA/480W

USB

OUTPUT SOCKETS

MAINS INPUT

TECHNICAL DETAILS

MODELS

POWER

INPUT

Rated voltage 220-240 Vac

Voltage range 230 Vac (+20/-26%)

Frequency 50/60 Hz auto sensing

OUTPUT

Voltage on mains operation 230 Vac (-8%, +10%)

Voltage on battery operation 230 Vac (+/- 5%)

Frequency on battery operation 50 or 60 Hz (+/- 0.5%)

Waveform from battery/inverter Pseudo sinewave

BATTERIES

Type VRLA AGM Maintenance-free lead-acid

Recharge time 6-8 h

ENVIRONMENTAL

Weight (kg) 5.8 6.2

Dimensions (hwd) (mm) 152 x 110 x 325

Communication USB

Compliance EN 62040-1-1 and Directive 2006/95/EC; EN 62040-3EN 62040-2 and Directive 2004/108 EC

Operating temperature 0°C ÷ +40°C

Colour Dark grey RAL 7016

Altitude and relative humidity 6000 meters max. elevation, < 95% non condensing

Accessories provided 2 output supply cables, comunication software; user guide

12

Dialog Vision500-3000 VA

Dia

log

Visi

on 5

00-3

000

VA

ECO LINE

90°

90°

The DIALOG VISION series includes the DVT (Tower version), DVR (Rack version) and DVD (Dual Rack/Tower version) with models from 500VA to 3000VA and uses sinewave digital technology.The DIALOG VISION range, with its advanced communications and connectivity options, is the ideal solution for the most demanding of customers looking for superior protection and versatility.

single-phase

DIALOG VISION is the best protection for network devices, rackmounted servers, conventional rack-mounted or tower servers, network storage systems.

1. Release the mimic panel by applying pressure to the catch

2. Rotate the mimic panel and fasten it back on again

3. Turn the UPS 90° 4. Slide the UPS into the rack cabinet

SMALL COMPUTERSNETWORK

LOCAL AREANETWORKS(LAN)

WORK- STATIONS

SERVERS EPOS (Electronic Point of Sales)SYSTEM

13

Dia

log

Visi

on 5

00-3

000

VA

DVR 50/80/110

DVD 150

DVT 50/80/110 DVT 150/200

DVD 220/300

VERY HIGH PROTECTIONAn Automatic Voltage Regulator (AVR) provides stabilisation from brownouts, sag and surge voltages. EMI filters then provide further protection from spikes and transients. When the mains power supply fails, the load is powered by the inverter and receives a true sinewave supply for maximum power continuity and reliability. The UPS also incorporates protection for PC and network, telephone line/modem connections (RJ45-RJ11).

HIGH AVAILABILITYOne PowerShare socket for load-shedding of the least critical loads to maximise back up time for the most critical servers.Hot swappable battery (front access) for simple and risk-free UPS maintenance.Additional Battery Boxes (with chargers) are available for the DVD 220 and 300 for long back up time applications.Battery Test facility to detect deteriorating battery performance and failure.Deep discharge protection: in the case of low load long discharge periods, the end-of-discharge voltage threshold is increased as recommended by battery manufacturers, in order to avoid damaging the battery

VERSATILITYDialog Vision Dual (DVD150, 220 and 300) can be placed directly onto the floor or mounted in 19’’ rackmount cabinets. The front panel digital display can be easily pulled out and rotated to suit the installation format.DVD and DVR versions include an Emergency Power Off (EPO) input contact.Cold Start function to allow a Dialog Vision to power up with no mains power supply present.

ADVANCED COMMUNICATION• Advanced communication, multiplatform, for all operating systems

and network environments: Powershield3 supervision and shut-down software included, with SNMP agent, for Windows 7, 2008, Vista, 2003, XP, Linux, Mac OS X, Sun Solaris, Linux, VMWare ESX operating systems and other Unix operating systems

• USB or RS232 serial port (selectable)• Slot-in SNMP network adapter card• LCD Display.

2 YEAR WARRANTY

SERIAL INTERFACE PORT RS232

TELEPHONE/IT NETWORKPROTECTION

MAINS INPUT IEC

SLOT FOR SNMP NETWORK

ADAPTER CARD

USB PORT

POWERSHARESOCKET

OUTPUT SOCKETS

IEC

BATTERY EXPANSION CONNECTOR

OUTPUT SOCKETS IEC 16A

THERMAL FUSES

EPO

TECHNICAL DETAILS

SERIAL INTERFACE

PORT RS232TELEPHONE/IT NETWORK

PROTECTION

MAINS INPUT IEC

POWERSHARESOCKET

OUTPUT SOCKETS IEC

USBPORT OUTPUT

SOCKETS IEC

14

Dia

log

Visi

on 5

00-3

000

VA

DVT 50 DVT 80 DVT 110 DVT 150 DVT 200

500VA/350W 800VA/540W 1100VA/740W 1500VA/1050W 2000VA/1350W

DVR 50 DVR 80 DVR 110 DVD 150 DVD 220 DVD 300

500VA/350W 800VA/540W 1100VA/740W 1500VA/1050W 2200VA/1540W 3000VA/2100W

BB 96-A5

DVD 220 - DVD 300

438 582

88

INPUT

Rated voltage 230 Vac (selectable 200, 208, 220, 240 V)

Voltage range 160 V - 294 V

Frequency 50/60 Hz auto sensing

Frequency range ±5%

OUTPUT

Rated voltage 230 Vac (selectable 200, 208, 220, 240 V)

Frequency 50 or 60 Hz auto sensing

Waveform True sinewave

BATTERIES

Type VRLA AGM Maintenance-free lead-acid

Recharge time 4-6 h

ENVIRONMENTAL

Protection Overload - short-circuit - overvoltage - undervoltage - temperature - low battery

Communication USB / RS232 / slot for interface communication

Compliance EN 62040-1-1 and Directive 2006/95/ECEN 62040-2 and Directive 2004/108 EC

Performance IEC / EN62040-3

Operating temperature 0°C ÷ +40°C

Storage temperature -15°C ÷ +45°C

Relative humidity < 95% non condensing

Noise < 50 dBA

Colour Dark grey RAL 7016

TOWER VERSION MODELS

POWER

Dimensions (hwd) (mm) 235 x 110 x 383 235 x 110 x 383 235 x 110 x 383 235 x 160 x 425 235 x 160 x 425

Weight (kg) 7.2 10.6 11 18 18.4

IEC mains input plug 1 (10A) 1 (10A) 1 (10A) 1 (10A) 1 (10A)

IEC output sockets 4 (10A) 4 (10A) 4 (10A) 4 (10A) 4 (10A)

RACK 1U and TOWER/RACK (Dual) 2U MODELS

POWER

Dimensions (hwd) (mm) 1U x 19” x 460 1U x 19” x 460 1U x 19” x 460 T 438 x 88 x 582R 2U x 19” x 582

T 438 x 88 x 582R 2U x 19” x 582

T 438 x 88 x 582R 2U x 19” x 582

Weight (kg) 12 13.5 15.6 28.7 31 32.8

IEC mains input plug 1 (10A) 1 (10A) 1 (10A) 1 (10A) 1 (16A) 1 (16A)

IEC output sockets 4 (10A) 4 (10A) 4 (10A) 8 (10A) 8 (10A) - 1 (16A) 8 (10A) - 1 (16A)

BATT. BOX MODELS

DVD MODEL

Dimensions (mm)h x w x d

15

Dia

log

Visi

on 5

00-3

000

VA

16

Premium Pro700-3000 VA

Prem

ium

Pro

700

-300

0 VA

ECO LINE

SMALL COMPUTERSNETWORK

LOCAL AREANETWORKS(LAN)

WORK- STATIONS

SERVERS EPOS (Electronic Point of Sales)SYSTEM

single-phase

PREMIUM PRO is the latest evolution of the successful Riello Dialog Plus online UPS. This latest development has been designed with the environment in mind and is part of the Riello ECO Line of UPS.PREMIUM PRO is an on-line double-conversion UPS offering the highest levels of reliability and protection for critical servers, voice and data processing IT systems.For long runtime applications, PREMIUM PRO (ER models) can be fitted with matching battery extension packs which also include additional battery boost chargers.In terms of communications, each PREMIUM PRO has a built-in mimic panel with an LCD to show input and output voltages, and battery charge status. The inverter is a totally new design, fully microprocessor controlled and constructed to achieve the highest levels of operating efficiency and configuration options. PREMIUM PRO UPS also have USB communication ports as standard, with a built-in expansion slot for additional adapters, protocol converters and relate contact cards.

The UPS is highly efficient. PREMIUM PRO is designed to save energy and has a power-off push-button feature to reduce energy consumption to zero, when no load is connected or switched off.PREMIUM PRO models include 700VA, 1000VA, 1500VA, 2200VA and 3000VA.

fEATURES• Filtered, stabilised, reliable output voltage: on-line double-conversion

technology (VFI in accordance with IEC 62040-3) with built-in EMI filters

• High overload capability up to 150%• Programmable auto-restart when mains power returns• Programmable cold-start from battery• Power factor correction (UPS input power factor close to 1)• Wide input voltage tolerance (from 120-280Vac) without battery usage• Possibility to extend autonomy for several hours • Fully configurable using UPS Tools configuration software

17

Prem

ium

Pro

700

-300

0 VA

PRP 100PRP 100 ER

PRP 70PRP 150

PRP 220PRP 220 ER

PRP 300PRP 300 ER

• High level of battery reliability (automatic and manually-activated battery tests)

• High level of UPS reliability (total microprocessor control)• Low impact on the mains (sinusoidal absorption)• Input protection with fuse which can be reset.

ADVANCED COMMUNICATION• Advanced communication, multiplatform, for all operating systems

and network environments, Powershield3 supervision and shut-down software included for Windows 7, 2008, Vista, 2003, XP, Linux, Mac OS X, Sun Solaris and VMware ESX operating systems and other Unix operating systems

• UPS Tools configuration and personalisation software supplied as standard

• RS232 serial port and opto-isolated contacts• USB port• Slot for communication cards.

2 YEAR WARRANTY

OUTPUT SOCKETS

THERMAL OUTPUTPROTECTION

INPUT THERMAL PROTECTION

BATTERYEXPANSION CONNECTOR

COMMUNICATION SLOTSERIAL

INTERFACE

USB PORT

INPUT SOCKET

TECHNICAL DETAILS

Display detail

18

Prem

ium

Pro

700

-300

0 VA

PRP 70 PRP 100 PRP 100 ER PRP 150 PRP 220 PRP 220 ER PRP 300 PRP 300 ER

700VA/560W 1000VA/800W 1500VA/1200W 2200VA/1760W 3000VA/2400W

MODELS

POWER

INPUT

Nominal voltage 220-230-240 Vac

Voltage range for no battery intervention 140 Vac < Vin < 276 Vac @50% LOAD / 184 Vac < Vin < 276 Vac @ 100% LOAD

Maximum permitted voltage 300 Vac

Nominal frequency 50/60 Hz

Frequency range 50 Hz ± 5% / 60 Hz ± 5%

Power factor > 0.99

Current distortion ≤7%

BY PASS

Voltage tolerance 180 - 264 Vac

Frequency tolerance Frequency selected (from ±0.Hz to ±5Hz configurable)

OUTPUT

Voltage distortion with linear load/with distorting load < 2% / < 4%

Frequency Can be selected: 50 Hz or 60 Hz or self-learning

Static variation ± 1%

Dynamic variation ≤ 5% in 20 msec.

Waveform Sinewave

Current crest factor 3 : 1

On Line / ECO Mode and Smart Active efficiency 98%

BATTERIES

Type VRLA AGM lead, maintenance-free

Charging time 2-4 hours N.A. 2-4 hours N.A. 2-4 hours N.A.

OVERLOAD TIMES

100% < Load < 110% 2 minutes

110% < Load < 150% 5 seconds

Load > 150% 1 second

ENVIRONMENTAL

Net weight (kg) 10,9 13,3 7 14,8 25,6 10,6 28 14

Gross weight (kg) 12,5 14,9 8,6 16,4 28,8 13,8 31,2 17,2

Dimensions (hwd) (mm) 158 x 422 x 235 190 x 446 x 333

Packaging dimensions (hwd) (mm) 245 x 500 x 340 325 x 585 x 470

Protection against overvoltages 300 joules

Protection devices Overcurrent - short circuit - overvoltage - undervoltage - circuit breaker - excessively low battery

Communication USB / DB9 with RS232 and contacts / Slot for communication interface

Standards Safety: EN 62040-1 and Directive 2006/95/EC; EMC: EN 620040-2 category C2 and Directive 2004/108/EC

Ambient temperature 0°C / +40°C

Relative humidity < 95% not condensed

Colour Black

Noise level < 40 dBA @ 1 m

Standard equipment Power cable, serial cable, USB cable, safety manual, quick start, software on CD-ROM

19

Prem

ium

Pro

700

-300

0 VA

BB 36-A3 / BB 36-M1 BB 72-A3 / BB 72-M1

PRP 100 PRP 220-300/ER

422

158

235

446

190

333

BATTERY BOX MODELS

PRP MODELS

Dimensions (mm)h x w x d

20

Premium Dual1000-3000 VA

Prem

ium

Dua

l 10

00-3

000

VA

ECO LINE

90°

90°

single-phase

PREMIUM DUAL is the high density version of the Premium Pro range of double-conversion on-line UPS. PREMIUM DUAL is designed to power critical loads such as servers, storage systems, telephone equipment, medical systems and industrial applications.The UPS is ideal for Blade servers with an input power factor close to Unity (1). The UPS has can be used as tower UPS or within a rackmount cabinet, and takes up only 2U in height.

PREMIUM DUAL has a modern design, choice of functional formats, and represents the state-of-the-art technology from the Riello UPS research & development team. The UPS can achieve an on-line operating efficiency of 92%.

1. Remove the synoptic panel 2. Rotate the synoptic panel and insert it in position

3. Rotate the UPS by 90º 4. Couple the rack supports

LocAL AreANetworks(LAN)

servers DAtA ceNters

INDUstrIAL PLcs

cAsh reGIsters

emerGeNcy DevIces (Lights/Alarms)

teLecom-mUNIcAtIoN DevIces

21

Prem

ium

Dua

l 10

00-3

000

VA

Rack version

PRD 150

PRD 100

BATTERY BOX

PRD 220/220ER300/300 ER

for critical business continuity applications requiring long runtimes, Premium Dual can be installed with battery extension packs (ER models) with their own internal battery chargers to maintain sensible recharge times.The UPS also incorporates the Riello UPS ‘power-off’ function found in other ECO Line UPS. PREMIUM DUAL is designed to save energy when no loads are connected.

SIMPLIfIED INSTALLATION• Tower or Rackmount UPS: Premium Dual can be installed as tower

or 19” rackmount UPS, with a front mimic panel that can be turned through 90º to suit the installation.

• Noise Free Operation (<40dBA): the UPS can be installed in any environment thanks to its PWM digitally-controlled high frequency inverter.

• High Temperature Operation: UPS components are sized for high temperature operation up to 40ºC and are not therefore stressed during normal operational environments.

• EnergyShare: Premium Dual output sockets can be programmed to disconnect less critical loads when the mains power fails.

REDUCED MANAGEMENT COSTSPREMIUM DUAL can be programmed remotely via software or set manually from the front mimic panel to operate in a range of energy saving operating modes:• On Line: maximum power protection and output voltage waveform

quality• ECO: to increase operating efficiency to 98% and provide line

interactive protection• Smart Active: with the UPS selecting automatically its operating

mode - ECO or On-Line dependent upon the reliability and quality of the local mains power supply.

• Backup: for emergencies only with the UPS only operating when mains power fails

• frequency converter: from 50 to 60Hz or 60 to 50Hz.

ADVANCED COMMUNICATIONPremium Dual offers maximum flexibility for integrations with any communication system.• Multiplatform communication for all operating systems and network

environments, Powershield3 supervision and shut-down software included for Windows 7, 2008, Vista, 2003, XP, Linux, Mac OS X, Sun Solaris and VMware ESX operating systems and other Unix operating systems.

• UPS Tools configuration and personalisation software supplied as standard.

• RS232 serial port and opto-isolated contacts.• USB port• Slot for communication cards such as Modbus/Jbus, TCP/IP, SNMP

and relay contacts.

HIGH OUTPUT VOLTAGE QUALITY• Even with distorting loads (IT loads with a crest factor of up to 3:1).• High short circuit current on bypass.• High overload capacity: 150% from inverter (even with no mains power).• Filtered, stabilised, reliable (On Line double conversion technology

(VFI in accordance with EN62040-2 class C1) standard with filters to

suppress atmospheric disturbances.• Load power factor correction: incoming UPS power factor close to 1

and sinusoidal current absorption.

HIGH LEVELS Of BATTERY RELIABILITY• Automatic and manual battery tests• Batteries are ‘hot-swappable’ and user replaceable.• Unlimited battery runtime extension using battery extension packs.

OTHER fEATURES• Output voltage can be selected using software (220-230-240V).• Auto-restart when mains power returns (programmed via software)• Stand-by on Bypass: when the machine is switched off, it

automatically goes into bypass operation with batteries charging.• Power-Off with zero load connected to save energy• Low battery warning• Power-on delay• Full microprocessor control.• Automatic bypass without interruption• Status, measurements and alarms available on the front panel mimic

panel and LCD• UPS firmware upgrade via PC platform• Input protection including a user reset thermal switch (up to 1500VA)• Back-feed protection• Manual option to switch to bypass.

2-YEAR WARRANTY

INPUT PLUG

OUTPUT SOCKETS

INPUT THERMAL PROTECTION

INPUTSOCKETS

EMERGENCY SWITCH DEVICE

(ESD)

RS232 SERIAL

USBPORT

BATTERY EXPANSION

OUTLET

TECHNICAL DETAILS

22

Prem

ium

Dua

l 10

00-3

000

VA

PRD 100 PRD 150 PRD 220 PRD 220 ER PRD 300 PRD 300 ER

1000VA/900W 1500VA/1350W 2200VA/1980W 2200VA/1760W 3000VA/2700W 3000VA/2400W

MODELS

POWER

INPUT

Nominal voltage 220-230-240 Vac

Voltage range for no battery intervention 140 Vac < Vin < 276 Vac @50% LOAD / 184 Vac < Vin < 276 Vac @ 100% LOAD

Maximum permitted voltage 300 V

Nominal frequency 50/60 Hz ±5Hz

Frequency range 50 Hz ± 5% / 60 Hz ± 5%

Power factor > 0.98

Current distortion ≤7%

BY PASS

Voltage tolerance 200 - 253 Vac

Frequency tolerance Frequency selected (from ±0.Hz to ±5Hz configurable)

OUTPUT

Voltage distortion with linear load/with distorting load < 2% / < 4%

Frequency Can be selected: 50 Hz or 60 Hz or self-learning

Static variation ±1%

Dynamic variation ≤5% in 20 msec

Waveform Sinewave

Current crest factor 3 : 1

On Line / ECO Mode and Smart Active efficiency 98%

BATTERIES

Type VRLA AGM lead, maintenance-free

Charging time 2-4 hours

OVERLOAD TIMES

100% < Load < 110% 1 minute

110% < Load < 150% 4 seconds

Load > 150% 0,5 seconds

ENVIRONMENTAL

Net weight (kg) 17.5 18 30.5 15 31 15

Gross weight (kg) 21 21.5 35 19.5 35.5 19.5

Dimensions (hwd) (mm) 87x425x450 (2Ux425x19”) 87x625x450 (2Ux625x19”)

Packaging dimensions (hwd) (mm) 550x600x245 600x760x245

Protection against overvoltages 300 joules

Protection devices Overcurrent - short circuit - overvoltage - undervoltage - circuit breaker - excessively low battery

Communication USB / DB9 with RS232 and contacts / Slot for communication interface

Standards Safety: EN 62040-1 and Directive 2006/95/EC; EMC: EN 620040-2 category C2 and Directive 2004/108/EC

Ambient temperature O°C / +40°C

Relative humidity < 95% not condensed

Colour Black

Noise level < 40 dBA @ 1 m

Standard equipment Power cable, serial cable, USB cable, safety manual, quick start, software on CD-ROM

N.B.: Consult us for the availability

23

Prem

ium

Dua

l 10

00-3

000

VA

BB 36-A3-ABB 36-M1-A

BB 72-A3-ABB 42-M1-A

PRD 100 PRD 220 - 300

625425

87 87

450

450

BATTERY BOX MODELS

PRD MODELS

Dimensions (mm)

h x w x d OPTIONS

Universal rails for installation in rack cabinets

Multipass 16 (mm/kg): 2U x 438 x 360 - rack version weight 6.8

24

Dialog Dual3,3-10 kVA

Dia

log

Dua

l 3,

3-10

kVA

6

90°

90°

ELECTRO-MEDICALDEVICES

LOCAL AREANETWORKS(LAN)

SERVERS DATA CENTERS

INDUSTRIAL PLCS

CASH REGISTERS

EMERGENCY DEVICES (Lights/Alarms)

single/single-phase and three/single-phase

1. Release the mimic panel by applying pressure to the catches

2. Rotate the mimic panel and fasten it back on again

3. Turn the UPS 90° 4. Slide the UPS into the rack cabinet

DIALOG DUAL is the best solution for protecting medium sized networking applications which require the highest possible levels of reliability. The UPS is designed to support a wide range of applications from IT to security. DIALOG DUAL is unique in that the UPS can be placed directly onto the floor or mounted in 19” rackmount cabinets. The range is available in 3.3-4-5-6-8-10 KVA models. The UPS is primarily an on-line double-conversion (VFI) technology system with

further selectable operating modes that can configure the UPS to protect applications including emergency lighting, security and medical systems.Each UPS features advanced communications and diagnostics including a digital front panel display that can be turned to suit the installation format, RS232 and USB interfaces, and an internal adaptor slot for SNMP and other interface card options from RIELLO UPS. PowerShield3 is supplied as standard.

25

Dia

log

Dua

l 3,

3-10

kVA

DLD 330DLD 400

DLD 500DLD 600

DLD 800DLD 1000

DLD 650 TMDLD 800 TM

DLD 1000 TM

SIMPLIfIED INSTALLATION• The UPS can be installed as a floor standing tower or 19” rackmount UPS. The front panel digital display can be pulled out (using the keys provided) and rotated to suit the installation format• Low noise level (<40dBA) thanks to the digitally PWM controlled ventilation system which is load and temperature dependent, and the use of an inverter with a high switching frequency• Optional bolt-on maintenance bypass (DLD 5-6-8-10 kVA models) to allow service without disruption to the loads• Performance guaranteed in temperatures up to 40°C• Two IEC output plugs with thermal protection (DLD5-6-8-10 kVA).• PowerShare output socket (2x10A IEC) functionality on DLD 5-6-8-10 kVA models

SELECTABLE OPERATING MODES• On line Mode (VFI).• Economy Mode: increases efficiency (up to 98%), and uses Line

Interactive technology to power low priority loads from the mains supply.

• Smart Mode: the UPS automatically decides which operating mode to use (VI or VFI) depending on the quality of the mains supply.

• Emergency Mode: the UPS can be set to operate only when mains power fails (emergency only mode).

• Frequency converter Mode (50 or 60 Hz).

GUARANTEED OUTPUT QUALITY• Even with typical distorting IT loads with crest factors of 3:1• Increased short circuit current on the bypass• Increased overload capacity: 150% on inverter even when mains supply has failed• Reliable, filtered, stabilised and regulated sinewave output (double conversion technology VFI in conformity with IEC 62040-3 specifications) with filters for atmospheric disturbance suppression• Rephasing of load as the UPS has an input power factor close to 1, with a sinusoidal input current

HIGHLY RELIABLE BATTERY PERfORMANCE• Automatic and manual battery tests• Unique Low Ripple Current Discharge (LRCD) to help prolong battery life• Hot-swap user replaceable batteries

• Unlimited extendable back-up time using modular design Battery Extension Packs• Increased ride through (without batteries) on mains breaks up to 40ms and for fluctuations ranging from 84 to 276Vac

OTHER CHARACTERISTICS• Output voltage selection: 220-230-240Vac• Auto restart when mains power returns - programmed using the UPS Tools Software supplied• Bypass on: when the UPS is switched off, it automatically goes into bypass mode to charge the batteries• Automatic power down due to minimum load • End of battery discharge pre-alarm• Delayed start up• Completely digitally controlled• Automatic bypass with no break in power supply• Use of IMS (Insulated Metallic Substrates) modules• Status, measurements, and alarms available on the standard backlit display• UPS can be updated digitally (flash upgradeable)• Input protected by resettable thermally activated switch• Back-feed protection: to avoid current being fed back into the mains should a fault occur• Manual switch over to bypass

ADVANCED COMMUNICATION• Advanced, multi-platform communication for all operating systems

and network environments: PowerShield3 monitoring and shut-down software included, for Windows 2008, Vista, 2003, XP; Mac OS X, Linux, Novell and most popular Unix operating systems.

•The UPS is supplied with a communications cable for ‘Plug and Play’ PC connection• USB port• RS232 serial port• Interface card slot

2 YEAR WARRANTY

TECHNICAL DETAILS

INPUT SOCKET

INTERFACE CARD SLOTSNMP OR ADDITIONALRS232 PORTS

OUTPUT SOCKETS

BATTERYEXTENSION PACK CONNECTOR

SERIAL PORT

USB PORT

INPUT THERMALPROTECTION RE-SET

INPUT CABLE ACCESS

OUTPUT CABLE ACCESS

26

Dia

log

Dua

l 3,

3-10

kVA

DLD 330 DLD 400 DLD 500 DLD 600 DLD 800 DLD 1000

3300VA/2300W 4000VA/2400W 5000VA/3500W 6000VA/4200W 8000VA/6400W 10000VA/8000W

MODELS

POWER

INPUT

Rated voltage 220-230-240 Vac

Minimum voltage 164 Vac @ load 100% / 84 Vac @ load 50%

Rated frequency 50/60 Hz ± 5 Hz

Power factor > 0.98

Current distortion ≤ 7%

BY PASS

Voltage range 180 - 264 Vac (selectable in Economy Mode and Smart Mode)

Frequency range Selected frequency ±5% (user configurable)

OUTPUT

Rated voltage 220-230-240 Vac selectable

Voltage distortion < 3% with linear load / < 6% with non-linear load

Frequency 50/60 Hz selectable

Static variation 1.5%

Dynamic variation ≤ 5% in 20 ms

Waveform Sinewave

Crest factor 3: 1

BATTERIES

Recharge time 4-6 h

OVERLOAD CAPACITY

100% < Load < 110% 1’

110% < Load < 150% 4”

Load > 150% 0.5”

ENVIRONMENTAL

Weight (kg) 38 40 62 64 80 85

Dimensions (hwd) (mm) 455 x 175 x 520 tower175(4U) x 483 x 520 rack

455 x 175 x 660 tower175(4U) x 483 x 660 rack

2 x 455 x 175 x 660 tower2 x 175(4U) x 483 x 660 rack

Efficiency up to 98%

Protection Overload - short-circuit - overvoltage - undervoltage - temperature - low battery

Communication USB / RS232 + communication interface slot

Compliance EN 62040-1 EMC EN 62040-2 Directives 2006/95/EC - 2004/108 EC EN 62040-3

Operating temperature 0°C ÷ +40°C

Relative humidity < 95% non condensing

Colour Dark grey

Noise < 40 dBA at 1 m < 45 dBA at 1 m

Accessories provided2x10A cables; 1xIEC-16A plug; software;

serial cable; plastic keys to release display; handles kit

2 cable guides; terminal board connection; software; serial cable;plastic keys to release display; handles kit

OPTIONS

Extended runtime solutions yes (with and without battery charger)

Telescopic rails for rack cabinet yes

27

Dia

log

Dua

l 3,

3-10

kVA

BB 108-7 - BC 108-14 BB 192-7BC 192-12

BB 240-A3BC 240-A5 BC 108-38

DLD 330-400 DLD 500-600 DLD 650TM-800-800TM-1000-1000TM DLD 330-400 Tower

DLD 650 TM DLD 800 TM DLD 1000 TM

6500VA/5200W 8000VA/6400W 10000VA/8000W

4U

19’’

455

175 520

520

4U

19’’

455

175 660660

630

215 655

4U = 176 mm; 19” = 438 mm

MODELS

POWER

INPUT

Rated voltage 400 Vac three-phase + N

Minimum voltage (PH + N) 164 Vac @ load 100% / 84 Vac @ load 50%

Rated frequency 50/60 Hz ± 5 Hz

Power factor > 0.95

BY PASS

Voltage range 180 - 264 Vac (selectable in Economy Mode and Smart Mode)

Frequency range Selected frequency ±5% (user configurable)

OUTPUT

Rated voltage 220-230-240 Vac selectable

Voltage distortion < 3% with linear load / < 6% with non-linear load

Frequency 50/60 Hz selectable

Static variation 1.5%

Dynamic variation ≤ 5% in 20 ms

Waveform Sinewave

Crest factor 3: 1

BATTERIES

Recharge time 4-6 h

OVERLOAD CAPACITY

100% < Load < 110% 1’

110% ≤ Load < 150% 4”

Load > 150% 0.5”

ENVIRONMENTAL

Weight (kg) 64 80 85

Dimensions (hwd) (mm) 2 x 455 x 175 x 660 tower / 2 x 175(4U) x 483 x 660 rack

Efficiency Smart Mode up to 98%

Protection Overload - short-circuit - overvoltage - undervoltage - temperature - low battery

Communication USB / RS232 + communication interface slot

Compliance EN 62040-1 EMC EN 62040-2 Directives 2006/95/EC - 2004/108 EC EN 62040-3

Operating temperature 0°C ÷ +40°C

Relative humidity < 95% non condensing

Colour Dark grey RAL 7016

Noise < 45 dBA at 1 m

Accessories provided 2 cable guides; terminal board connection; software; serial cable; plastic keys to release display; handles kit

BATT. BOX MODELS

DLD MODEL

Dimensions (mm)h x w x d

28

Power Dialog 35-6 kVA

Pow

er D

ialo

g 3

5-1

0 kV

A

6,5 -10 kVA6

EMERGENCY DEVICES (Lights/Alarms)

ELECTRO-MEDICALDEVICES

LOCAL AREANETWORKS(LAN)

SERVERS DATA CENTERS

INDUSTRIAL PLCS

CASH REGISTERS

TELECOM-MUNICATION DEVICES

single/single-phase

single/single-phase and three/single-phase

POWER DIALOG 3 is the ideal solution for powering vital mission critical, sensitive loads such as electro-medical security applications in order to guarantee maximum reliability and availability.The series includes 5kVA-6kVA single/single phase and 6.5kVA-8kVA-10kVA single/single phase and three/single phase models and uses double conversion on-line technology (VFI). The load is powered constantly by the inverter which supplies filtered, stabilised and regulated sinewave voltage.

Moreover, the input and output filters increase the immunity of the load against mains power disturbances and lightning strikes.POWER DIALOG 3 is without doubt one of the best UPS systems on the market today thanks to the technology used, the features (selectable Economy Mode and Smart Mode) and the diagnostics offered (custom LCD display, RS232 and USB interfaces complete with Powershield3 software, EPO contact and slots for optional interface boards).

29

Pow

er D

ialo

g 3

5-1

0 kV

A

HIGH UPS RELIABILITY• Full microprocessor control.• No break static and maintenance bypass.• Features guaranteed up to 40°C (the components are designed to

operate at high temperatures and thus are subject to less stress at ordinary temperatures).

SELECTABLE OPERATING MODESThe operating mode can be programmed using the software or selected manually on the digital front panel display.• On line Mode (VFI).• Economy Mode: increases efficiency (up to 98%), and uses Line

Interactive (VI) technology to power low priority loads from the mains supply.

• Smart Mode: the UPS automatically decides which operating mode to use (VI or VFI) depending on the quality of the mains supply.

• Emergency Mode: the UPS can be set to operate only when mains power fails (emergency only mode).

• Frequency converter Mode (50 or 60 Hz).

HIGH QUALITY OUTPUT VOLTAGE• Even with distorting loads (IT loads with crest factor of up to 3:1).• High short circuit current on bypass.• High overload capacity: 150% on inverter, even when mains power

fails.• Filtered, stabilised and reliable voltage (double conversion on-line

technology, VFI compliant with EN62040-3 specifications, with filters to suppress atmospheric interference).

• Rephasing of the load: UPS input power factor close to 1 with sinusoidal current absorption.

SIMPLIfIED INSTALLATION• The UPS can be connected to both single phase and three phase

mains supplies. • Output terminal board + 2 IEC plugs to power local equipment

(computers, modems, etc.). • Easy to move thanks to built-in wheels.

HIGH BATTERY RELIABILITY• Automatic and manual battery tests.• Low Ripple Current Discharge system “LRCD” to prolong battery life.• Unlimited extendable runtime thanks to dedicated modular design

Battery Boxes. • Increased ride-through for mains failures up to 40ms (high hold up

time) and for fluctuations in the input current ranging from 84V to 276V).

LOW IMPACT ON MAINS POWER• Sinusoidal input current on single phase/single phase series.

OTHER fEATURES• Filtered, stabilised and reliable current (double conversion on-line

technology, VFI compliant with EN62040-3 specifications, with filters to suppress atmospheric interference).

• Advanced diagnostics: status, measurements and alarms available on the custom LCD display

• Very low noise level (<40dBA): for installation in any environment thanks to the PWM digitally controlled ventilation that is load dependent, and the use of an inverter with high switching frequency (>20kHz, value above the audible range)

• Autorestart when mains power returns, can be programmed using software or the digital front panel display

• Emergency mode: the UPS can be programmed to work only when mains power fails (suitable for emergency lighting)

• Standard back feed protection: to avoid current being fed back into the mains system.

• Digital updating of the UPS (flash upgradable)

ADVANCED COMMUNICATION• Compatible with the Riello TeleNetGuard remote assistance system. • Advanced, multi-platform communication for all operating systems

and network environments: PowerShield3 monitoring and shut-down software included, for Windows 2008, Vista, 2003, XP; Mac OS X, Linux, Novell and most popular Unix operating systems.

• RS232 serial port.• Plug and Play connection.• Slots for communication interface boards.

Rear view

Display

30

Pow

er D

ialo

g 3

5-1

0 kV

A

PWN 500 PWN 600 PWN 650 PWN 800 PWN 1000

5000VA/4000W 6000VA/4800W 6500VA/5200W 8000VA/6400W 10000VA/8000W

MODELS

POWER

INPUT

Rated voltage 220-230-240 Vac single-phase 220-230-240 Vac single-phase or 380-400-415 Vac three-phase with neutral

Minimum voltage without battery intervention 170 Vac @ load 100% / 140 Vac @ load 50%

Rated frequency 50/60 Hz ± 5 Hz

BY PASS

Voltage range 180 - 264 Vac (selectable in Economy Mode and Smart Mode)

Frequency range Selected frequency ±5 Hz

OUTPUT

Rated voltage 220 - 230 - 240 Vac selectable

Voltage distortion < 3% with linear load / < 6% with non-linear load

Frequency 50/60 Hz selectable or auto sensing

Static variation ± 1,5 %

Dynamic variation ≤ 5% in 20 ms

Waveform Sinewave

Crest factor ≥ 3: 1

BATTERIES

Recharge time 6 - 8 h

OVERLOAD CAPACITY

100% < Load < 125% 1’

110% ≤ Load < 150% 4”

Load ≥ 150% 0.5”

ENVIRONMENTAL

Weight (kg) 89 90 91 94 95

Dimensions (hwd) (mm) 615 x 282 x 785

Efficiency Smart Mode up to 98%

Protection Overload - short-circuit - overvoltage - undervoltage - temperature - low battery

Communication RS232 + USB + remote contacts + communication interface slot

Compliance EN 62040-1 EMC EN 62040-2 Directives 2006/95/EC - 2004/108 EC EN 62040-3

Operating temperature 0°C ÷ +40°C

Relative humidity < 95% non condensing

Colour Dark grey RAL 7016

Noise < 45 dBA at 1 m

OPTIONS

Extended runtime solutions yes (with and without battery charger)

Isolation transformer box (HxWxD) mm/kg 500 x 400 x 265 / 80 -

Product characteristics can be customised to meet client specifications.

31

Pow

er D

ialo

g 3

5-1

0 kV

A

BB240-A3-ABB240-A5-ABB240-A7-ABC240-M1-ABC240-M5-A

615

282785

PWN 500 - PWN 600PWN 650 - PWN 800

PWN 1000

BATTERY BOX MODELS Dimensions (mm) h x w x d

TECHNICAL DETAILS

USB PORT

EMERGENCY POWER OFF (EPO)

ON/OFF SWITCHCOMMUNICATION INTERFACE SLOT

OUTPUT SWITCH (SWOUT)

MAINTENANCE BYPASS (SWMB)

SERIALINTERFACE PORT

BATTERY FUSE HOLDERS (SWBT)

INPUT SWITCH (SWIN)

IEC SOCKETS

32

Multi Plus10-20 kVA

Mul

ti Pl

us 1

0-40

/10

0-12

0 kV

A

10-40 kVA100-120 kVA

6

EMERGENCY DEVICES (Lights/Alarms)

ELECTRO-MEDICALDEVICES

LOCAL AREANETWORKS(LAN)

SERVERS DATA CENTERS

INDUSTRIAL PLCS

CASHREGISTERS

TELECOM-MUNICATION DEVICES

E-BUSINESS (Servers Farms, ISP/ASP/POP)

single-phase

MULTI PLUS has been designed and manufactured using state-of-the-art technologies in order to deliver maximum protection for critical users, a zero impact on the mains power supply and a high operating efficiency.The high level of flexibility at the design stage means that there is full compatibility both with three-phase power and with single-phase sources, thus eliminating any critical factors in the connection between UPS and system.

MULTI PLUS is ideal for the protection of critical information and telecommunications networks which cannot run the risk of being powered from a poor quality electrical supply.The MULTI PLUS series is available in 10-12-15-20 kVA three-phase and single-phase input and single-phase output models, and 10-12-15-20-30-40 and 100-120 kVA three-phase input and output models, with double conversion on-line technology according to the VFI-SS-111 classification, as defined by the IEC EN 62040-3 standard.

three-phase

33

Mul

ti Pl

us 1

0-40

/10

0-12

0 kV

A

Display MLT 10-20

100

98

96

94

92

90

88

86

84

82

80

78

760 20 30 40 60 80 100 120

MLT 40traditional UPS 40kVA

% load

% E

ffic

ienc

y

ZERO IMPACT SOURCEThe superior technology of a MULTI PLUS UPS allows it be used where the site mains power supply is limited in capacity, or has an on-site generator and/or loads that generate current harmonic problems.MULTI PLUS is designed to have a zero-impact on its upstream power supply (mains or generator):• Input current distortion < 3%• Input power factor 0.99• Power walk-in function to guarantee a progressive rectifier start-up• Delayed switch-on function, to sequentially restart the UPS when

installed as part of a parallel system.MULTi PLUS also act as a filter and phase-shift protection device in respect to its upstream supply, providing protection from any harmonic components or reactive power generated by downstream loads.

HIGH EffICIENCYHigh operating efficiency up to 96.5% providing a 50% saving in energy usage per annum compared to traditional UPS products (92%). This exceptional performance can lead to a full initial investment recovery within three years. The efficiency values quoted were tested independently by TÜV Rheinland.

BATTERY CARE SYSTEMBattery management is one of the fundamentals of UPS management in order to ensure the system can perform in emergencies. The Multi Plus Battery Care System consists of a number of functions that together guarantee optimum battery performance.Battery recharge: Multi Plus is suitable for use with sealed Valve Regulated (VRLA), AGM, GEL and open-vented lead acid batteries, in addition to Nickel-Cadmium. Depending on the battery type used, the recharging functions can include: • One-level recharge, typical for the most commonly used VRLA AGM batteries• Two voltage level recharge according the IU characteristic• Charge blocking system to reduce consumption of the electrolyte and further extend the life of VRLA batteries.Compensation of the recharge voltage according to temperature in order to avoid excessive battery charging currents and potential overheating problems.Battery Test in order to detect battery performance deterioration or failure.Protection against deep discharges: during extended low load discharges, the end-of-discharge voltage is increased as recommended by battery manufacturers, to prevent damage to the battery set.Current Ripple: recharge current ripple (residual AC component) is one of the most common causes of poor battery performance and reduced operating life. Multi Plus, with its high-frequency battery-charger, produces negligible current ripple levels and therefore helps to extend operating life.

Wide voltage range: the rectifier can operate from a wide input range (up to 40% at half load), reducing battery usage and helping to extend their operational life.

MAXIMUM RELIABILITY AND AVAILABILITYConnect up to 6 units in parallel or N+1 redundancy, even of different power ratings. The UPS continue to operate in parallel even if one of the interconnecting communication cables is disconnected (closed loop).

LOW MANAGEMENT COSTThe high performance components and technology used by Multi Plus means that the UPS achieves exceptional performance and efficiency levels, from a very small footprint and overall compact dimensions:• the lowest footprint in this category, only 0.26 m2 for 20kVA Multi Plus, batteries included• the type of input stage guarantees a power factor close to 1 and a low

current distortion without the addition of filters, which can be expensive and bulky

• output power factor of 0.9 providing up to 15% more active power than a traditional UPS and more load expansion

ADVANCED COMMUNICATIONMulti Plus is equipped with a graphic display that provides information, measures, states and alarms regarding the UPS in 5 different languages• Advanced, multi-platform communication for all operating systems

and network environments: PowerShield3 monitoring and shut-down software included, for Windows 2008, Vista, 2003, XP; Mac OS X, Linux, Novell and most popular Unix operating systems

• Compatible with the TeleNetGuard remote service monitoring system• RS232 or USB serial port• 3 slots for the installation of optional communication accessories such as network adapters and volt-free contacts• REPO (Remote Emergency Power Off) with which to power down the UPS through a remote emergency pushbutton• Input for connection of the auxiliary contact of an external manual bypass• Input for synchronisation from an external source• Graphic mimic panel display for remote connection

Display MLT 10-20

34

Mul

ti Pl

us 1

0-40

/10

0-12

0 kV

A

25 50 75 100 (% P UPS) P

100

80

60

40

20

% PA 0

20

40

60

80

100

(% PA UPS) PQ

(% PA UPS) PQ

PERSONAL COMPUTERS

TECHNICAL DETAILS

fLEXIBILITYMulti Plus is suitable for use in a broad spectrum of applications, thanks to a variety of configurations, accessories and options providing flexibility and a choice of performance levels:• suitable for powering capacitive loads, such as blade servers, without any

reduction in active power (0.9 lead to 0.9 lag)• multiple operating modes: On Line, Eco, Smart Mode and Stand By Off• Frequency converter mode• configurable Power Share connections to ensure backup for the most

critical loads or programmed to operate only when mains power fails •Cold Start facility that starts the UPS even when it is not connected to the

mains • MLT/MLM X version: in cabinet (1320x440x850 HWD) provides optimum

solutions when medium or long term runtime is required • optional temperature sensor for external battery cabinets, to assist the

recharge voltage compensation• additional battery chargers to optimise recharge times• optional dual input to mains power supply• isolation transformer options to vary neutral connectivity in the event of

separate power sources or for galvanic isolation input and output • battery cabinets of various sizes and capacities to ensure prolonged runtime.

CAPACITIVELeading

INDUCTIVELagging

P.F. 0.9eg: 10 kVA UPS supplies9 kW load

P.F. 1eg: 10 kVA UPS supplies9 kW load

P.F. 0.9eg: 10 kVA UPS supplies9 kW load

REPO - AS400USB - RS232

CONNECTORS

BATTERYFUSES

SERIALINTERFACE PORT

CONNECTORS REMOTE

CONTACTS

COMMUNICATION INTERFACE SLOT

COMMUNICATION INTERFACE SLOT

COMMUNICATION INTERFACE SLOT

POWERSHARE SOCKETS

PARALLELCONNECTORS

PARALLELCONNECTORS

USB PORT

BYPASS FUSE HOLDER (SWBYP)

INPUT SWITCH (SWIN)

INPUT SWITCH (SWIN)

MAINTENANCE BYPASS (SWMB)

OUTPUT SWITCH (SWOUT)

OUTPUT SWITCH (SWOUT)

CONNECTORSREPO - AS400USB - RS232

MAINTENANCEBYPASS (SWMB)

BYPASS SWITCH(SWBYP)

MULTICOM 382 SLOT

POWERSHARE SOCKETS

MLT/MLM 10-20

MLT 10 - 12 - 15 - 20(rear)

MLM 10 - 20 XMLT 10 - 40 X

(front)

MLT 100 - 120(front)

MLM 10 - 12 - 15 - 20

35

Mul

ti Pl

us 1

0-40

/10

0-12

0 kV

A

MLM 10 MLM 12 MLM 15 MLM 20 MODELS

INPUT

Rated voltage 380-400-415 Vac three-phase with Neutral / 220-230-240 single-phase

Rated frequency 50/60 Hz

Frequency tolerance 40 ÷ 72 Hz

Power factor at full load 0.99

Current distortion THDI ≤ 3%

BY PASS

Rated voltage 220-230-240 Vac

Number of phases 1

Voltage tolerance 180 ÷ 264 V (selectable)

Rated frequency 50/60 Hz (selectable)

Frequency tolerance ±5 (selectable)

OUTPUT

Rated power (kVA) 10 12 15 20

Active power (kW) 8 9.6 12 16

Output power factor 0.8

Number of phases 1

Rated voltage (V) 220-230-240 Vac (selectable)

Static variation ± 1%

Dynamic variation ± 3%

Crest factor (Ipeak/Irms) 3: 1

Voltage distortion ≤ 1% with linear load / ≤ 3% with non-linear load

Frequency 50/60 Hz

Frequency stability on battery mode 0.01%

Overload at pF 0.8 110% for 10 minutes, 133% for 1 minute, 150% for 5 seconds

BATTERIES

Type VRLA AGM/GEL

Recharge time 6 h

ENVIRONMENTAL

Weight with internal batteries (Kg) 180 182 190 195

Dimensions (hwd) (mm) 930 x 320 x 840 / 1320 x 440 x 850 (version MLM X)

Communication 3 communication interface slots/RS232/USB

Operating temperature O°C / +40°C

Relative humidity 90% non condensing

Colour Dark Grey RAL 7016

Noise < 52 dBA at 1 m

Protection rating IP20

Efficiency Smart Mode ≥ 98% in Economy mode

Compliance

European Directives: L V 2006/95/CE Low voltage directiveEMC 2004/108/EC Electromagnetic compatibility directive

Standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2 C2Classification according to IEC 62040-3 (Voltage Frequency Independent) VFI - SS - 111

36

Mul

ti Pl

us 1

0-40

/10

0-12

0 kV

A

MLT 10 MLT 12 MLT 15 MLT 20 MLT 30 X MLT 40 X MLT 100 MLT 120

(*) weight without batteries

MODELS

INPUT

Rated voltage 380-400-415 Vac three-phase with Neutral

Rated frequency 50/60 Hz

Frequency tolerance 40 ÷ 72 Hz

Power factor at full load 0.99

Current distortion THDI ≤ 3%

BY PASS

Rated voltage 380-400-415 Vac three-phase with Neutral

Number of phases 3 + N

Voltage tolerance 180 ÷ 264 V (selectable)

Rated frequency 50/60 Hz (selectable)

Frequency tolerance ±5 (selectable)

OUTPUT

Rated power (kVA) 10 12 15 20 30 40 100 120

Active power (kW) 9 10.8 13.5 18 27 36 90 108

Output power factor 0.9

Number of phases 3 + N

Rated voltage (V) 380-400-415 Vac (selectable)

Static variation ± 1%

Dynamic variation ± 3%

Crest factor (Ipeak/Irms) 3: 1

Voltage distortion ≤ 1% with linear load / ≤ 3% with non-linear load

Frequency 50/60 Hz

Frequency stability on battery mode 0.01%

Overload at pF 0.8 115% unlimited, 125% for 10 minutes, 150% for 1 minute, 168% for 5 seconds

BATTERIES

Type VRLA AGM/GEL

Recharge time 6 h

ENVIRONMENTAL

Weight with internal batteries (Kg) 180 182 190 195 335 350 460 (*) 480 (*)

Dimensions (hwd) (mm) 930 x 320 x 8401320 x 440 x 850 (MLT X version) 1320 x 440 x 850 1900 x 750 x 855

Communication 3 communication interface slots /RS232/USB

Operating temperature O°C / +40°C

Relative humidity 90% non condensing

Colour Dark Grey RAL 7016

Noise < 52 dBA at 1 m < 48 dBA at 1 m < 65 dBA at 1 m

Protection rating IP20

Efficiency Smart Mode up to 99%

Compliance

European Directives: L V 2006/95/CE Low voltage directiveEMC 2004/108/EC Electromagnetic compatibility directive

Standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2 C2Classification according to IEC 62040-3 (Voltage Frequency Independent) VFI - SS - 111

37

Mul

ti Pl

us 1

0-40

/10

0-12

0 kV

ABB 480X-M5

BB 480X-M6 / BB 480-M7 BB 480-B1BB 480Y-J8 / BB 480Y-J9BB 480Y-K1 / BB 480Y-K2

AB 480Y-B0

MLM 10 - 12 - 15 - 20 MLT 10 - 12 - 15 - 20 - 30 - 40

MLM 10 - 12 - 15 - 20 MLT 10 - 12 - 15 - 20 - 30 - 40

100 - 120

800

1900

860750

1600

650

1320

815400

Display MLT 30-120

BATTERY BOX MODELS

MODEL

Dimensions (mm)h x w x d

38

Multi Dialog mdtMDT 60-80 kVA

Mul

ti D

ialo

g M

DT 6

0-80

kVA

4

BB 576-26M

BB BB576-B1

BB 576-65M

BB 576-80M

BB 576-100M

60 60-80 60-80 60-80 60-80

500 740

1400

650 750

1600

900750

1600

860 800

1900

three/three-phase

BATTERYBOXES

MOD. MDT

Dimensions (mm)h x w x d

The MULTI DIALOG series includes 60-80 kVA three-phase models, and uses double conversion on-line technology (VFI). The load is powered continuously by the inverter with a filtered, Stabilised and regulated sinewave supply. The input and output filters considerably increase the immunity of the load to mains disturbances and surges, even on bypass.

LOW POWER CONSUMPTION• On-line Mode: up to 92% efficiency can be achieved due to the use of IGBT technology, increasing to 98% in one of the other operating modes• Economy Mode: uses Line Interactive (VI) technology to power less critical loads from the mains supply for certain periods• Smart Mode: if the mains supply is out of range, the UPS will power the load from the inverter as an On-line UPS. When the mains supply returns to within range again, the UPS will monitor this for a certain period before selecting Line Interactive operation

MAXIMUM RELIABILITY AND AVAILABILITY• Connect up to 8 units in parallel or N+1 redundancy, of even different power ratings

EMERGENCY DEVICES (Lights/Alarms)

ELECTRO-MEDICALDEVICES

LOCAL AREANETWORKS(LAN)

SERVERS DATA CENTERS

INDUSTRIAL PLCS

CASH REGISTERS

TELECOM-MUNICATION DEVICES

E-BUSINESS (Servers Farms, ISP/ASP/POP)

39

Mul

ti D

ialo

g M

DT 6

0-80

kVA

MDT60 MDT80HIGH LEVEL BATTERY RELIABILITY• Automatic battery test• Recharge compensated for temperature• Automatic or manual rapid charge (boost) – duration progammable

SENSITIVE SUPPLY COMPATIBLEFor power supply sources that are particularly sensitive to harmonics (generator sets or transformers of low power with respect to that of the UPS) it is often a good idea to take action to limit the harmonics injected back into the supply by the UPS.MULTI DIALOG AF series have an active filter and use high frequency Insulate Gate Bipolar Transistor (IGBT) Technology with Digital Signal Processor (DSP) control. The Active Filter helps to reduce harmonics generated by the UPS into the supply which could disrupt the operation of upstream generators and transformers whose rating is closely matched to that of the UPS• Advanced technology Multi Dialog AF systems reduce harmonic distortion of the phase and neutral currents. The Digital Signal Processor (DSP) and the “current mode” instantly control and monitor the input current to maintain a perfect sinewave with 4% harmonic distortion• Maximum efficiency Multi Dialog AF systems have low input distortion even at low loads and their overall efficiency is not affected by generator frequency variations or line impedance• Reduction of neutral current Multi Dialog AF systems reduce the input neutral current by up to 3.5 times their nominal rating to help avoid oversizing input protections and conductors• Maximum reliability Multi Dialog AF systems are extremely reliable. Overall UPS performance is unaffected should the harmonic filter fail.• Excellent capabilities input distortion: (THDi) 4% input power factor: > 0.99

Multi Dialog can also be supplied without the Active Filter for installations less sensitive to current harmonics.

OTHER CHARACTERISTICS• Suitable for powering capacitive loads such as blade servers, without any reduction of the active power, from 0.8 leading to 0.8 lagging• High level diagnostics: event log with 128 messages, states,

measurements and alarms - available from the built-in LCD in several languages

• Reduced noise levels: high frequency inverter bridge • Back feed protection standard: to avoid energy feeding back into the mains supply• Power factor correction (input power factor, close to 1)• By pass may be deactivated to allow operation as a frequency converter (at 50 or 60 Hz)• Emergency operation: the UPS can be set to operate only when the mains fails (for emergency lighting)

ADVANCED COMMUNICATION• Compatible with TeleNetGuard for remote maintenance• Advanced, multi-platform communication for all operating systems and

network environments: PowerShield3 monitoring and shut-down software included, for Windows 2008, Vista, 2003, XP; Mac OS X, Linux, Novell and most popular Unix operating systems.

• The UPS is supplied with a communications cable for ‘Plug and Play’ PC connection

• Double RS232 serial ports• Network adapter slot for SNMP agent• Emergency Power Off (EPO) shutdown input contact• Remote control mimic panel

MDT MODELS

INPUT

Rated voltage 400 Vac Three-phase + N

Voltage range ± 20%

Frequency range 45 ÷ 65 Hz

Power factor >0.99

Current distortion THDI 4% (AF version)

BY PASS

Rated voltage 400 Vac

Number of phases 3 + N

Permitted voltage range ± 15% (selectable from ± 5% a ± 25%)

Rated frequency 50/60 Hz

Permitted frequency range ± 2% (selectable from ± 1% a ± 5%)

OUTPUT

Rated power (kVA) 60 80

Active power (kW) 48 64

Number of phases 3 + N

Rated voltage (V) 380 - 400 - 415 V selectable

Voltage regulation range 346 ÷ 422 V

Crest factor (Ipeak/Irms) 3: 1

Waveform Sinewave

Distortion with linear load 2%

Static stability ± 1%

Dynamic stability ± 5% in 10 ms

Frequency 50/60 Hz selectable

Overload 125% 150% of the rated current for 10’/1’

BATTERIES

Type Lead, flooded and VRLA AGM / GEL; NiCd

Recharge time 4-8 h

ENVIRONMENTAL

Weight (kg) 180 192

Dimensions (hwd) (mm) 1400 x 500 x 740

Input Three-phase + N

Remote signalling Volt free contacts

Remote controls EPO and Bypass

Communication Double RS232/C + remote contacts + communication interface slot

Operating temperature O°C / +40°C

Relative humidity < 95% non condensing

Colour Dark grey RAL 7016

Noise < 56 dBA at 1 m < 60 dBA at 1 m

Protection rating IP20

Efficiency Smart Mode > 98.5 %

Compliance EN 62040-1 EMC EN 62040-2 EN 62040-3

40

Master Plus10-800 kVA

10-100 kVA

Mas

ter

Plus

10-

800

kVA 6

three/three-phase

three/single-phase

ABSOLUTE PROTECTIONMaster Plus is an on-line double conversion UPS (VFI SS 111 in accordance with IEC EN 62040-3) with a transformer isolated inverter. Master Plus has a compact foot print and high quality output to provide the ultimate power protection for “mission critical” applications: data processing, tele-communications, industrial processes, security and electro-medical systems. The Master Plus range includes three-phase output models from 10 to 800kVA, and single-phase output models from 10-100kVA – all with a three phase input. Models from 10-200kVA are available with a 6 or 12 pulse rectifier. From 100kVA to 400kVA Master Plus is available in a HIP (High Input Performance) format with an IGBT-based rectifier offering even lower input harmonic distortion (THDi) and unity input power factor. From 500kVA to 800kVA Master Plus has a 12-pulse rectifier as standard.

EASY SOURCEMaster Plus technology removes the problems of over sizing upstream power sources, whilst improving load power factors and current harmonics. The UPS features the latest input-current absorption techniques including progressive rectifier start-up and the option to reduce battery charging currents. These features make Master Plus one of the most generator and environmentally friendly UPS available.

POWER CONTINUITYRiello UPS has been researching and developing UPS technologies for critical applications, worldwide and for many years. Riello UPS solutions are flexible, offering the highest levels of availability, whilst achieving low total cost of ownership.Riello UPS are designed to be resilient, with key component inbuilt redundancy. The UPS are designed for ease of installation and maintenance, with top entry cable cabinet options, and simple but secure access to connection terminals and communications interfaces.

EMERGENCY DEVICES (Lights/Alarms)

ELECTRO-MEDICALDEVICES

LOCAL AREANETWORKS(LAN)

SERVERS DATA CENTERS

INDUSTRIAL PLCS

TELECOM-MUNICATION DEVICES

E-BUSINESS (Servers Farms, ISP/ASP/POP)

INDUSTRIAL PROCESSES

41

Mas

ter

Plus

10-

800

kVA

Batte

ry

Maintenance Bypass Cabinet

Load

Bypass mains

Mains

UPS1 UPS2 UPS3... UPS8

Mains Mains

Batte

ry

Batte

ry

Batte

ry

Load

Bypass mains

Mains

UPS1 UPS2 UPS3... UPS8 CommonBY PASS

Mains Mains

Batte

ry

Batte

ry

UPS1A UPS2A

UGSSinchroniser

Static TransferSWITCH

Bypass 1System A

Load 1

Batte

ry

Mains

System B Bypass 2

Mains Mains Mains

Batte

ry

Batte

ry

Batte

ry

UPS1B UPS2B

Load 2

Load 4

Load 3

Static TransferSWITCH

UPS1A UPS2A

PSJ

SWITCH

Bypass 1System A

Load 1

Batte

ry

Mains

System B Bypass 2

Mains Mains Mains

Batte

ry

Batte

ry

Batte

ry

UPS1B UPS2B

Load 2

MAXIMUM LEVELS Of RELIABILITY AND AVAILABILITYDistributed or centralised parallel up to 8 units per backup (N+1) or power parallel. A parallel between models with different power levels is possible.Hot System Expansion (HSE): HSE allows the insertion of a new UPS within an existing system, without the need to switch off the UPSs which are already operating or switch them to bypass mode.This guarantees maximum load protection, even during maintenance and enlargement.Maximum levels of availability also in the event of an interruption to the parallel bus cable: the system is “FAULT TOLERANT”. It is not affected by faults with the connection cables and continues to power the load without a continuity solution, signalling the anomaly with an alarm.High Efficiency Parallel System (HEPS): this is the system which optimises the efficiency of the system in parallel, according to the power required by the load at that moment. The N+1 redundancy is nevertheless guaranteed, but each UPS operating in parallel operates at the best possible load level in order to achieve the highest overall efficiency.

OPTIONS• UGS - UPS Group Synchroniser Allows 2 or more UPS not in parallel to remain synchronised even during a power failure. The UGS also enables a RIELLO UPS to be synchronised with an independent power source, even of a different power rating. • PSJ - Parallel Systems Joiner Connects two UPS groups operating in parallel configurations through a power coupling switch. The Slave UPS Group is permanently synchronised to the Master group. Should one of the UPS in one of the parallel groups fail, the PSJ will automatically connect the remaining UPS to the other group via an external bypass.

Parallel architecture which guarantees the redundancy of the power source. + flexibility and modularity

Solution which ensures redundancy until the distribution of the power supply to the loads + Downstream fault discrimination

Parallel configuration of up to 8 units with distributed bypass

Dynamic dual bus configuration

Parallel configuration of up to 8 units with common bypass

Parallel architecture which guarantees the redundancy of the power source, with autonomous bypass management. + Selectivity downstream faults in bypass mode

Solution which guarantees the redundancy of the power supply even during maintenance + High levels of availability and redundancy

Dual bus system configuration

42

Mas

ter

Plus

10-

800

kVA

32004400

1000

1900

1900

980

MP 100 - MP 120 MP 160- MP 200MM/MP 10÷40 MM/MP 60÷80 MM 100

800 800

1900

1070 800

1900

800 740

1400

555740

1400

12 MP 500 - 12 MP 600 12 MP 800

25 50 75 100 (% P UPS) P

100

80

60

40

20

% PA 0

20

40

60

80

100

(% PA UPS) PQ

(% PA UPS) PQ

BATTERY CARE SYSTEM: MAXIMUM LIfETIME POTENTIALTraditionally, when a mains supply is present the UPS charges its batteries. Battery power is used for the inverter should the input supply fail. Efficient battery management and care is therefore essential to the overall performance of the UPS in an emergency. The Master Plus Battery Care System consists of a range of features designed to provide optimum performance and enhanced operating life:• Dual level charging regime to optimise recharge currents and lower recharge times• Temperature compensation and deep discharge protection to reduce overall battery aging

fLEXIBILITYMaster Plus is suitable for a wide range of applications including IT and the most demanding industrial environments. The UPS is suitable for power capacitive loads such as blade servers, without any reduction in active power, from 0.9 leading to 0.8 lagging. With a broad range of accessories and options, complex configurations and system architectures can be achieved to guarantee maximum power availability and the option to add new UPS without interruption to existing users. Using the Riello UPS Group Synchroniser (UGS) and Parallel Systems Joiner (PSJ) sophisticated inter group parallel and redundant systems can be achieved to provide the highest possible levels of resilience and availability.

• Charge blocking system to reduce electrolyte consumption and lengthen the life of VRLA batteries• Predictive battery testing to spot potential battery deterioration and failureMaster Plus is also compatible with different battery technologies: open-vented lead acid and AGM and Gel VRLA, NiCd.

EASE Of INSTALLATIONMaster Plus is compact with a foot print of only 0.64 m2 for a 200kVA system. Front access to internal assemblies and top panel ventilation make space allocation within confined data processing or plant rooms easy. Master Plus can be placed against a wall as there is no requirement for rear or side panel access for maintenance or ventilation.

SPECIfIC SOLUTIONSThe UPS can be adapted to your requirements. Please contact TEC to discuss specific applications and options.

ADVANCED COMMUNICATION• Compatible with TeleNetGuard for remote maintenance• Advanced, multi-platform communication for all operating systems

and network environments: PowerShield3 monitoring and shut-down software included, for Windows 2008, Vista, 2003, XP; Mac OS X, Linux, Novell and most popular Unix operating systems. The UPS is supplied with a cable for direct connection to the PC (Plug and Play)

• Double RS232 serial port• Installation slot for an Emergency Power Off (EPO) interface to allow

the UPS to be switched off remotely in an emergency.• Generator interface: enables desynchronisation of the UPS output from a generator supply which may be subject to phase and frequency variations. The interface also enables more economic use of the battery charger.

MT 100 - 800 load diagram

Dimensions (mm)

CAPACITIVELeading

INDUCTIVELagging

P.F. 0.9eg: 100 kVA UPS supplies80 kW load

P.F. 1eg: 100 kVA UPS supplies80 kW load

P.F. 0.8eg: 100 kVA UPS supplies80 kW load

43

Mas

ter

Plus

10-

800

kVA

MM 10* MM 15* MM 20* MM 30 MM 40 MM 60 MM 80 MM 100

10 15 20 30 40 60 80 100

MODELS

POWER (kVA)

INPUT

Nominal voltage 380 - 400 - 415 Vac three-phase

Voltage tolerance 400 V + 20% /- 25%

Frequency 45 ÷ 65 Hz

Soft start 0 ÷ 100% in 30’’ (selectable)

Permitted frequency tolerance ± 2% (selectable from ± 1% to ± 5% from the front panel)

Standard features Back Feed protection; separable bypass line

BATTERIES

Type Lead, flooded and VRLA AGM / GEL; NiCd

AC ripple < 1%

Temperature compensation -0.5 Vx°C

Typical charging current 0.2 x C10

OUTPUT

Rated power (kVA) 10 15 20 30 40 60 80 100

Active power (kW) 9 13,5 18 27 36 54 72 90

Number of phases 1

Nominal voltage 220 - 230 - 240 Vac single-phase

Static stability ± 1%

Dynamic stability ± 5% in 10 ms

Voltage distortion < 1% with linear load / < 3% with no-linear load

Crest factor (lpeak/lrms) 3:1

Frequency stability on battery mode 0.05%

Frequency 50 or 60 Hz (selectable)

Overload 110% for 60’; 125% for 10’; 150% for 1’

ENVIRONMENTAL

Weight (kg) 200 220 230 290 340 440 520 650

Dimensions (hwd) (mm) 1400 x 555 x 740 1400 x 800 x 740 1400 x 555 x 740

Remote signalling Voltage-free contacts

Remote commands EPO and bypass

Communication double RS232 + remote contacts + 2 communication interface slots

Operating temperature 0°C / +40°C

Relative humidity < 95% non condensing

Colour Light grey RAL 7035

Noise 54 62 62 63

Protection rating IP20

Efficiency Smart Mode Up to 98%

Compliance European Directives: L V 2006/95/CE; EMC 2004/108/EC; Safety IEC EN 62040-1; EMC IEC EN 62040-2 C2

Classification according to IEC 62040-3 (Voltage Frequency Independent) VFI - SS - 111

* Also available with internal batteries

N.B.: Consult us for the availability

new new new new new new new new

44

Mas

ter

Plus

10-

800

kVA

MP 10* MP 15* MP 20* MP 30 MP 40 MP 60 MP 80

10 15 20 30 40 60 80

MODELS

POWER (kVA)

INPUT

Nominal voltage 380 - 400 - 415 Vac three-phase

Voltage tolerance 400 V + 20% /- 25%

Frequency 45 ÷ 65 Hz

Soft start 0 ÷ 100% in 30’’ (selectable)

Permitted frequency tolerance ± 2% (selectable from ± 1% to ± 5% from the front panel)

Standard features Back Feed protection; separable bypass line

BATTERIES

Type Lead, flooded and VRLA AGM / GEL; NiCd

AC ripple < 1%

Temperature compensation -0.5 Vx°C

Typical charging current 0.2 x C10

OUTPUT

Rated power (kVA) 10 15 20 30 40 60 80

Active power (kW) 9 13,5 18 27 36 54 72

Number of phases 3 + N

Nominal voltage 380 - 400 - 415 Vac three-phase + N

Static stability ± 1%

Dynamic stability ± 5% in 10 ms

Voltage distortion < 1% with linear load / < 3% with no-linear load

Crest factor (lpeak/lrms) 3:1

Frequency stability on battery mode 0.05%

Frequency 50 or 60 Hz (selectable)

Overload 110% for 60’; 125% for 10’; 150% for 1’

ENVIRONMENTAL

Weight (kg) without batteries 210 * 220 * 230 280 330 450 600

Dimensions (hwd) (mm) 1400 x 555 x 740 1400 x 800 x 740

Remote signalling Voltage-free contacts

Remote commands EPO and bypass

Communication double RS232 + remote contacts + 2 communication interface slots

Operating temperature 0°C / +40°C

Relative humidity < 95% non condensing

Colour Light grey RAL 7035

Noise 54 60 62

Protection rating IP20

Efficiency Smart Mode Up to 98%

Compliance European Directives: L V 2006/95/CE; EMC 2004/108/EC; Safety IEC EN 62040-1; EMC IEC EN 62040-2 C2

Classification according to IEC 62040-3 (Voltage Frequency Independent) VFI - SS - 111

new new new new new new new

* Also available with internal batteries

N.B.: Consult us for the availability

45

Mas

ter

Plus

10-

800

kVA

MP 100 MP 120 MP 160 MP 200

100 120 160 200

MODELS

POWER (kVA)

INPUT

Nominal voltage 380 - 400 - 415 Vac three-phase

Voltage tolerance 400 V + 20% /- 25%

Frequency 45 ÷ 65 Hz

Soft start 0 ÷ 100% in 30’’ (selectable)

Permitted frequency tolerance ± 2% (selectable from ± 1% to ± 5% from the front panel)

Standard features Back Feed protection; separable bypass line

BATTERIES

Type Lead, flooded and VRLA AGM / GEL; NiCd

AC ripple < 1%

Temperature compensation -0.5 Vx°C

Typical charging current 0.2 x C10

OUTPUT

Rated power (kVA) 100 120 160 200

Active power (kW) 80 96 128 160

Number of phases 3 + N

Nominal voltage 380 - 400 - 415 Vac three-phase + N

Static stability ± 1%

Dynamic stability ± 5% in 10 ms

Voltage distortion < 1% with linear load / < 3% with no-linear load

Crest factor (lpeak/lrms) 3:1

Frequency stability on battery mode 0.05%

Frequency 50 or 60 Hz (selectable)

Overload 110% for 60’; 125% for 10’; 150% for 1’

ENVIRONMENTAL

Weight (kg) 640 650 770 810

Dimensions (hwd) (mm) 1900 x 800 x 800

Remote signalling Voltage-free contacts

Remote commands EPO and bypass

Communication double RS232 + remote contacts + 2 communication interface slots

Operating temperature 0°C / +40°C

Relative humidity < 95% non condensing

Colour Light grey RAL 7035

Noise 63 ÷ 68 dBA at 1 m

Protection rating IP20

Efficiency Smart Mode Up to 98%

Compliance European Directives: L V 2006/95/CE; EMC 2004/108/EC; Safety IEC EN 62040-1; EMC IEC EN 62040-2 C2

Classification according to IEC 62040-3 (Voltage Frequency Independent) VFI - SS - 111

46

Mas

ter

Plus

10-

800

kVA

12 MP 500 12 MP 600 12 MP 800

500 600 800

OPTIONS

Isolation transformer module

UPS Group Syncroniser (see UGS)

Hot connection device (see PSJ)

MODELS

POWER (kVA)

INPUT

Nominal voltage 380 - 400 - 415 Vac three-phase

Voltage tolerance 400 V ± 20%

Frequency 45 ÷ 65 Hz

Power factor > 0.93 in HC version

Current distortion < 3% in HC version

Soft start 0 ÷ 100% in 30’’ (selectable)

Permitted frequency tolerance ± 2% (selectable from ± 1% to ± 5% from the front panel)

Standard features Back Feed protection; separable bypass line

BATTERIES

Type Lead, flooded and VRLA AGM / GEL; NiCd

AC ripple < 1%

Temperature compensation -0.5 Vx°C

Typical charging current 0.2 x C10

OUTPUT

Rated power (kVA) 500 600 800

Active power (kW) 400 480 640

Number of phases 3 + N

Nominal voltage 380 - 400 - 415 Vac three-phase + N

Static stability ± 1%

Dynamic stability ± 5% in 10 ms

Voltage distortion < 1% with linear load / < 3% with no-linear load

Crest factor (lpeak/lrms) 3:1

Frequency stability on battery mode 0.05%

Frequency 50 or 60 Hz (selectable)

Overload 110% for 60’; 125% for 10’; 150% for 1’

ENVIRONMENTAL

Weight (kg) 3600 4000 5300

Dimensions (hwd) (mm) 1900 x 3200 x 1000 1900 x 4400 x 1000

Remote signalling Voltage-free contacts

Remote commands EPO and bypass

Communication double RS232 + remote contacts + 2 communication interface slots

Operating temperature 0°C / +40°C

Relative humidity < 95% non condensing

Colour Light grey RAL 7035

Noise < 75 dBA at 1 m < 78 dBA at 1 m

Protection rating IP20

Efficiency Smart Mode Up to 98%

Compliance European Directives: L V 2006/95/CE; EMC 2004/108/EC; Safety IEC EN 62040-1; EMC IEC EN 62040-2 C2

Classification according to IEC 62040-3 (Voltage Frequency Independent) VFI - SS - 111

Interface for generator

Closed Loop parallel kit option (to be ordered with the UPS)

Empty or full battery cabinets for prolonged runtime

47

Mas

ter

Plus

10-

800

kVA

TI 10 T / TI 15 TTI 20 T / TI 30 T

TI 40 TTI 60 T / TI 80 T TI 100 T / TI 120 T

TI 160 T TI 200 T / TI 250 T TI 300 T / TI 400 TTI 500 T / TI 600 T

BB 396-J8 / BB 396-J9BB 396-K1 / BB 396-K2

AB 480-A0 / BB 480-J8BB 480-J9 / BB 480-K1

BB 480-K2BB 384-38C 384-65D / 384-80D

384-100D / 384-120D

MP 100-200MM 100

12MP 500-800MP 100-400 HIP MP 10-60 MP 10-80

TE 270 TE 400 C TE 400 L

MP 100-200 / MM 100 MP 100 HIP / MP 250 HIP 12 MP 500-800 / MP 300-400 HIP

1900

860 800

1900

400 850

1900

400 1000

1900

650 800

1400

640 720

1200

555 720

1900

800 800

1900

1200 1000

1400

555 740

1400

860 740

1900

800270

ISOLATIONTRANSfORMERMODULE

Dimensions (mm)

h x w x d

BATTERY BOXMODELS

UPS MODELS

Dimensions (mm)

h x w x d

CABINETS WITH TOP CABLE ENTRY

UPS MODELS

Dimensions (mm)

h x w x d

48

Mas

ter

Plus

HIP

100

-400

kVA

Master Plus HIP100-400 kVA

6

MP 100-HIPMP 120-HIP

MP 300-HIPMP 400-HIP

MP 160-HIPMP 200-HIPMP 250-HIP

800 850

1900

1000 850

1900

1500 1000

1900

The new HIP version available in 100 to 400kVA models has been added to the Master Plus series. Thanks to the double conversion on-line technology achieved entirely with IGBT and DSP (Digital Signal Processor) control, the Master Plus HIP series guarantees maximum protection as well as high quality power for any type of IT and industrial load. It is especially suited for mission critical applications and is classed VFI SS 111 (Voltage and Frequency Independent) in compliance with IEC EN 62040-3 standards.This series has been designed using a new configuration that includes an IGBT rectifier with sinusoidal input current in place of the traditional thyristor rectifier.

Dimensions (mm)

three-phase/three-phase

EMERGENCY DEVICES (Lights/Alarms)

ELECTRO-MEDICALDEVICES

LOCAL AREANETWORKS(LAN)

SERVERS DATA CENTERS

INDUSTRIAL PLCS

TELECOM-MUNICATION DEVICES

E-BUSINESS (Servers Farms, ISP/ASP/POP)

INDUSTRIAL PROCESSES

49

Mas

ter

Plus

HIP

100

-400

kVA

ZERO IMPACT SOURCEMaster Plus HIP is a further evolution of the Master Plus series with the added advantages offered by an IGBT-based rectifier assembly. This feature further reduces the impact of the UPS on the local supply and simplifies installation where there is limited power capacity in the form of available electrical supply rating or generator size. Master Plus HIP is classed as a ‘Zero Impact Source’ and provides:• low input current distortion – less than 2.5%• high input power factor 0.99• power walk-in function that ensures progressive rectifier start up• delayed start up phased with the return of mains power supply, when several UPS are connected in the system.Master Plus HIP also performs the role of a high performance filter, protecting its upstream power supply sources from any harmonics and reactive power generated by the loads powered.

BATTERY CARE SYSTEMMaster Plus HIP uses the Battery Care System, also available on the traditional Master Plus models, which optimises battery performance in order to extend the battery life for as long as possible.

fLEXIBILITYMaster Plus models (including the HIP versions) feature an output transformer with galvanic isolation (between the load and the battery supply) to provide greater versatility and installation options. The UPS can be supplied from two separate power sources (mains power and a second emergency standby source) which can help increase the resilience of parallel system configurations.

MAIN CHARACTERISTICS• Efficiency up to 98,5 %• Compact footprint: only 0.85 m2 for the 250kVA UPS model• Reduced weight• Double electronic and galvanic protection of the load from the battery

The whole Master Plus HIP range is suitable for use in the widest selection of applications; thanks to the flexible configurations, accessories and optionals available, it is suitable for powering capacitive loads, such as blade servers etc.Reliability and availability of the power supply for critical applications are guaranteed by the distributed or centralised parallel of up to 8 units, for a backup (N+1) or power parallel and by all the various configurations available in the Master Plus range.

OPTIONS

Isolation transformer

Synchroniser device (see Master Plus UGS)

Parallel Systems Joiner device (see Master Plus PSJ)

Interface for generator set

Closed Loop kit (to be ordered with the UPS)

Empty battery cabinets or cabinets for extended runtime (Battery Box modules BB 480 A0) (Master Plus)

50

Mas

ter

Plus

HIP

100

-400

kVA

MP 100-HIP MP 120-HIP MP 160-HIP MP 200-HIP MP 250-HIP MP 300-HIP MP 400-HIP

100 120 160 200 250 300 400

MODELS

POWER (kVA)

INPUT

Nominal voltage 380 - 400 - 415 Vac three-phase

Range acceptable without battery intervention 300÷480 Vac

Frequency 45÷65 Hz

Power factor > 0,99

Current harmonic distortion <3% THDi

Soft start 0÷100 in 30” (selectable)

Frequency tolerance ± 2% (selectable between ± 1% a ± 5% from the front panel)

Standard features Back Feed protection; separable bypass line

BATTERIES

Type Free lead-acid, and VRLA AGM / GEL; NiCd

Ripple current Zero

Recharge voltage compensation -0.5 Vx°C

OUTPUT

Nominal power (kVA) 100 120 160 200 250 300 400

Active power (kW) 80 96 128 160 200 270 360

Number of phases 3 + N

Nominal voltage 380 - 400 - 415 Vac 3-phase + N

Static stability ± 1%

Dynamic stability ± 5% in 10 ms

Voltage distortion < 1% with linear load / < 3% with distorting load

Peak factor (lpeak/lrms) 3:1

Frequency stability on battery 0.05%

Frequency 50 or 60 Hz (selectable)

Overload 110% for 60’; 125% for 10’; 150% for 1’

ENVIRONMENTAL

Weight (kg) 656 700 800 910 1000 1400 1700

Dimensions (hwd) (mm) 1900 x 800 x 850 1900 x 1000 x 850 1900 x 1500 x 1000

Remote signals Voltage-free contacts (configurable)

Remote commands EPO and bypass (configurable)

Communication Twin RS232 + remote contacts + 2 slots for communication interface

Environment temperature 0°C / +40°C

Relative humidity < 95% non-condensing

Colour RAL 7035 light grey

Noise level 63 ÷ 68 dBA at 1 m 70 ÷ 72 dBA at 1 m

Protection rating IP20 (others on request)

Efficiency Smart Mode Up to 98,5%

Compliance Safety: EN 62040-1-1 (directive 2006/95/EC); EMC: EN 62040-2 (directive 2004/108/EC)

Classification according to IEC 62040-3 (Voltage Frequency Independent) VFI - SS - 111

51

Mas

ter

Plus

HIP

100

-400

kVA

52

Master Plus Industrial30-80 kVA

Mas

ter

Plus

Indu

stria

l 30

-80

kVA

1600 800

1900

800 800

1900

MPI 30 - MPI 40 MPI 60 - MPI 80

three-phase/single-phaseDC BUS 220 Vdc

Dimensions (mm)

PROTECTION fOR INDUSTRIAL APPLICATIONMaster Plus Industrial is an on-line double conversion UPS (VFI SS 111 in accordance with IEC EN 62040-3) with a transformer isolated inverter and rectifier. Master Plus Industrial has a compact foot print and high quality output to provide the ultimate power protection for industrial applications: industrial and petrochemical processes, power plants and energy distribution systems.

INDUSTRIAL ENVIRONMENTMaster Plus Industrial is suitable for severe installation environments such as petrochemical manufacturing sites, where the operating conditions (levels of vibration, mechanical stress, ambient temperatures and dust ingress) require a more robust and industrialised UPS design to those installed within, for example, data centres.

HIGH IccA high short-circuit current (Icc = 3 In) making the UPS suitable for loads with high current peaks; during switch-on or a load step-change.

220V DC VOLTAGEAn input transformer and isolated inverter to protect the 220Vdc bus bar (from 108 to 114 blocks), the recognised industrial standard.

INDUSTRIAL PLCS

INDUSTRIAL PROCESSES

53

Mas

ter

Plus

Indu

stria

l 30

-80

kVA

MPI 30 MPI 40 MPI 60 MPI 80

30 40 60 80

REDUNDANT VENTILATION100% redundant ventilation with 50% fan loading at nominal load and each fan monitored for breakdown or failure.

The Easy Source input, the Battery Care System as well as the flexibility and communication features are the same as those offered on the traditional Master Plus series.

MODELS

POWER (kVA)

INPUT

Nominal voltage 380 - 400 - 415 Vac three-phasee

Voltage tolerance 400 V ± 20%

Frequency 45 ÷ 65 Hz

Power factor ≥ 0.93

Current distortion < 5% C

Soft start 0 ÷ 100% in 30’’ configurable

Permitted frequency tolerance ± 2% (selectable from ± 1% to ± 5% from the front panel)

Standard features Back Feed protection; separable bypass line

BATTERY

Number of cells 108 ÷ 114

Max Vdc 274 V

Temperature compensation -0,5 Vx°C

OUTPUT

Rated power (kVA) 30 40 60 80

Active power (kW) 24 32 48 64

Nominal voltage 230 Vac single phase

Static stability ± 1%

Dynamic stability ± 5%

Voltage distortion < 1% with linear load / < 3% with distorting load

Frequency 50 or 60 Hz configurable

Peak factor 3:1

Overload 110% for 60’; 125% for 10’; 150% for 1’

Short circuit current 3 Inom.

SYSTEM

Remote signalling Voltage-free contacts

Remote commands EPO and bypass

Communication double RS232 + remote contacts + 2 communication interface slots

Efficiency Up to 94%

Dimensions (hwd) (mm) 1900 x 800 x 800 1900 x 1600 x 800

Weight (kg) 850 900 1400 1500

Noise level 63 ÷ 68 dBA a 1 m

Ventilation Redundant fans

Operating temperature 0 °C ÷ +40 °C

Relative humidity < 95% non condensing

Protection rating IP20

Colour RAL 7035

Compliance Safety: EN 62040-1-1 (directive 2006/95/EC); EMC: EN 62040-2 (directive 2004/108/EC)

Classification according to IEC 62040-3

(Voltage Frequency Independent) VFI - SS - 111

54

Mas

ter

Plus

400

Hz

30-

120

kVA

Master Plus 400 Hz30-120 kVA

550 740

1200

800 800

1900

MP 80 fC 400 - MP 100 fC 400MP 120 fC 400MP 30 fC 400

MP 60 fC 400

INDUSTRIAL PLCS

INDUSTRIAL PROCESSES

three-phase/three-phase

Master Plus FC 400 series is a frequency converted based on the Master Plus UPS that can accept 50/60Hz and deliver a 400Hz output. The device has a double-conversion design (VFI SS 111 compliant with IEC EN 62040-3) with a transformer-isolated Inverter.The output voltage is 208Vac and configurable at 200Vac on site with a 115Vac version available on request.

The basic design is a solid state generator with IGBT- based Inverter controlled using PWM techniques.It is ideal for applications such as avionic repair workshops, hangars, aircraft ground power in civil airports and military bases.

MINIMUM IMPACT ON POWER SUPPLY – EASY SOURCESMP FC 400 technology removes the problems of over sizing upstream power sources, whilst improving load power factors and current harmonics.The UPS features the latest input current absorption techniques including progressive rectifier start-up and the option to reduce battery charging currents.These features make MP FC 400 one of the most generator compatible and environmentally friendly UPS available.

Dimensions (mm)

55

Mas

ter

Plus

400

Hz

30-

120

kVA

MP 30 fC 400 MP 60 fC 400 MP 80 fC 400 MP 100 fC 400 MP 120 fC 400

30 60 80 100 120

EASY TO INSTALLMP FC 400 is compact with a foot print of only 0.64 m2. Front access to internal assemblies and top panel ventilationmake space allocation within confined data processing or plant rooms easy. MP FC 400 can be placed against a wall as there is no requirement for rear or side panel access for maintenance or ventilation.

APPLICATIONS• Aircraft ground power• Airports• Navy• Military equipment• Testing laboratories

OPTIONS• Input Isolation transformer• 2 Programmable relay cards• LCD based remote Control panel• Remote Graphics Panel• Input Isolation transformer• Protection degrees higher than IP20• Parallel/Redundant N+X operation.

MODELS

POWER (kVA)

INPUT

Nominal voltage 380 - 400 - 415 Vac three-phase

Voltage tolerance 400 V ± 20%

Frequency 45 ÷ 65 Hz

Power factor ≥ 0.93 (HC Version)

Current distortion < 5% C (HC Version)

Soft start 0 ÷ 100% in 120’’ configurable

OUTPUT

Rated power (kVA) 30 60 80 100 120

Active power (kW) 24 48 64 80 96

Nominal voltage 230 Vac three-phase + Neutral

Static stability ± 1%

Dynamic stability ± 5%

Voltage distortion < 3% with linear load / < 4% with distorting load

Frequency 400 Hz

Crest factor 3:1

Overload 110% for 60’; 125% for 10’; 150% for 1’

SYSTEM

Remote signalling Voltage-free contacts

Remote commands EPO and ON/OFF

Communication double RS232 + remote contacts + 2 communication interface slots

Efficiency Up to 92%

Dimensions (hwd) (mm) 1200 x 550 x 740 1900 x 800 x 800

Weight (kg) 330 480 500 530 560

Noise level 61 ÷ 63 dBA at 1 m

Operating temperature 0 °C ÷ +40 °C (50°C @ 75% load)

Relative humidity < 95% non condensing

Protection rating IP20 (other on request)

Colour RAL 7035 light grey

Compliance Safety: EN 62040-1-1 (directive 2006/95/EC); EMC: EN 62040-2 (directive 2004/108/EC)

Classification according to IEC 62040-3

(Voltage Frequency Independent) VFI - SS - 111

56

Multi Switch

Mul

ti Sw

itch

Input 1

Input 2

Ouput 1

Max 4 A

Ouput 2

Max 4 A

Ouput 3

Max 4 A

Ouput 4

Max 4 A

Ouput 5

Max 4 A

Ouput 6

Max 4 A

Ouput 7

Max 4 A

Ouput 8

Max 4 A

Multi-SWITCH is a rackmount source transfer switch that can supply up to eight loads from two AC power sources. Should one source fail, the other automatically powers the load. The sources can be two separate AC sources including mains power and UPS, or a combination of the two.

PRINCIPLE Of OPERATIONThe Multi-SWITCH provides electrical distribution and remote management for up to eight network users, powered from two direct mains supplies or UPS or a combination of both.The Multi-SWITCH can connect each user (up to eight, each with a maximum power demand not greater than 4A), to either of the two power sources (1 and 2). Load demand is shown on the LCD. See “principle of operation” diagram.

PROTECTION AGAINST POWER SUPPLY fAILURESIf one of the two power source fails or falls outside specification, Multi-SWITCH will transfer the connected loads to the second power source (switching is instantaneous even if the two sources are not in phase).

PROTECTION AGAINST LOAD fAULTS If a fault occurs with one of the loads (for example due to a short-circuit or overload), Multi-SWITCH will disconnect the load to prevent disruption to the others. Multi-SWITCH protects sensitive installations from both power and hardware faults.

SERVERS

57

Mul

ti Sw

itch

MODELS MSW

8 x 4A output sockets

INPUT

Input voltage 180 - 276 Vac

Rated frequency 50/60 Hz

Maximum load for each input (A) 16

Input sockets 2 IEC 320 (16A)

OUTPUT

Output voltage Selection of one of the two input sources

Maximum load for each output (A) 4

Output sockets 8 IEC 320 10A

ENVIRONMENTAL

Weight (kg) 10

Dimensions (hwd) (mm) 2U x 19” x 360

Operating temperature 0°C ÷ +40°C

Relative humidity < 95% non condensing

Protection Overcurrent - overvoltage - undervoltage - back-feed protection

Compliance EN 62040-1 EMC EN 62040-2 Directives 2006/95/EC - 2004/108/EC; EN 62040-3

Maximum altitude 3000 m

Max. altitude (storage conditions) 6000 m; 45 °C

Communication RS232 in MSW-S / Ethernet in MSW-N

Enclosure protection rating IP 20

Colour Dark grey RAL 5004

Noise < 35 dBA at 1 m

Product characteristics can be customised to meet client specifications.

CHARACTERISTICS• Full protection against mains failures and load faults• Flexible power sources: Multi-SWITCH can be powered from 2 different sources (2 mains supplies, 2 UPS or a combination of both. Note than the UPS can be of a different size)• Designed for installation in a 19” rack-mount cabinet• LCD to provide measurements/alarms/states information• Management software included• Remote monitoring serial interface• No signal connection is required between Multi-SWITCH and the power sources or supplied hardware• Configuration software provided as standard• Slot-in SNMP network adapter card

fRONT

OUTPUT SOCKET INPUT SOCKETS

BACK

INPUT THERMAL PROTECTION RESET

TECHNICAL DETAILS

SERIAL RS232version “S”

ETHERNETversion “N”

MSW (2 input - 8 output)

58

Mas

ter

Switc

h

Master Switch

SERVERS

MASTER SWITCH is a static transfer switch commonly used within power continuity applications to improve resilience. The system can be used in conjunction with UPS or as separate standalone devices.

OPERATING PRINCIPLEMASTER SWITCH adds a source of redundancy to a critical installation and automatically transfers the connected load between two separate AC power sources. The transfer can be automatic when an input power

supply fails outside set tolerances or be manually forced using the front panel keypad or remotely via a communications network.

PROTECTION AGAINST POWER fAILURES In the event that one of the two power sources does not return to the accepted tolerance values, the MASTER SWITCH will transfer the other loads over to the second power source (this happens instantly if the two sources are in phase).

59

Mas

ter

Switc

h

685 530 685 580

1500 17

70

950 730

1900

MTS 100-XMTS 150-X MTS 600-X

MTS 200-X MTS 250-XMTS 300-XMTS 400-X

S4-1

inputMCCB 2

MaintenanceSwitch 2

MaintenanceSwitch 1

OutputSwitch 1

3P + NOutput

3P + NSource 1

input

3P + NSource 2input

inputMCCB 1

S4-2 SS2

S2

SS1

S1

S3

Dimensions (mm)

PROTECTION AGAINST ENVIRONMENTAL DISTURBANCESOVERLOADS AND LOAD fAULTSIn the event of an overload or fault condition, the internal protection system within the STS device can be configured to disconnect power at defined levels. In the extreme situation of a downstream short circuit MASTER SWITCH can disconnect the load to prevent disruption.

CHARACTERISTICS• Full protection of critical industrial and IT applications against power

failures and faults on the load.• Full microprocessor control which guarantees:

- fast and safe transfer between the power sources. - monitoring of all parameters on the LCD display.- Constant control of the SCRs- Remote advanced diagnostics (RS232 and TCP/IP)

• Redundant power circuits: - Power is supplied to the internal logic by two separate and

independent power circuits that are hot swappable so as to ensure no break in the supply to the loads.

- In the event that the power supplied by both sources fails, full system operation is guaranteed by the Power Supply Backup function that provides backup power to the circuits from an external, independent standby power source.

• High protection - In the event of an output short circuit, MASTER SWITCH will block

the transfer between the two power sources eliminating the risk of propagating the short circuit and its effects on the other loads.

- A backfeed control circuit will trigger automatic protection devices to avoid energy feeding back to one of the inputs of the MASTER SWITCH.

- MASTER SWITCH has double redundant ventilation called “fan redundancy plus”. Thanks to this function, in the remote possibility that two fans both fail at the same time, the others would still be able to dissipate the heat generated at nominal load. The fans can be hot swapped so as to ensure no break in system operation during the repair.

• Easy front access - power cable connections are easily accessed with entry from below- board slots are positioned in a dedicated area to allow rapid

diagnosis/replacement- all parts subject to controls, maintenance and/or replacement.

LED fUNCTION

L1 S1 Priority source

L2 S2 Priority source

L3 S1 Present

L4 S2 Present

L5 Static switch SS1 closed

L6 Static switch SS2 closed

L7 Alarm indicator

L8 Output selection ON/OFF

5 function keys and LCD operations

Display

60

Mas

ter

Switc

h

[PS]

[PS]

[PS]

[PS]

[AS]

[AS]

[AS]

[AS]

[AS]

[PS]

UPS

USER 1

USER 2

Independentseparate lines

USER 1

UPS UPS

UPS UPS

USER 1

USER 2

MASTER SWITCH in

REDUNDANT ModeThe reliable secondary source [AS] will power the load only and exclusively when the primary source (PS) fails, so as to guarantee maximum redundancy and quality of the power supply to the loads.

MASTER SWITCH in

CROSS fEEDING ModeThe two sources power a number of critical loads using the MASTER SWITCHES configured in such a way as to make one of the two power sources the priority source (PS). In cases of power faults or failure on one of the two sources, the other one will be able to supply power to all the loads connected to the system.

MASTER SWITCH in

BACK UP ModeMASTER SWITCH powers a number of loads using the priority source (PS). The secondary source (AS) is formed by independent and separate sources which can supply standby power should the priority source (PS) fail suddenly

UGSSinchroniser

Static TransferSWITCH

Bypass 1System A

Load 1

Bat

tery

Mains

UPS1A

System B Bypass 2

Mains Mains Mains

Bat

tery

Bat

tery

Bat

tery

UPS2A UPS1B UPS2B

Load 2

Load 4

Load 3

Static TransferSWITCH

DYNAMIC DUAL BUS CONFIGURATION

The solution offered by RIELLO UPS guarantees maximum reliability and ensures no break power supply in all operating conditions thanks to the UGS option that keeps the two systems A and B perfectly synchronised.The flexibility of the UGS system is able to guarantee that the power sources remain synchronised even when one of the two systems is not a RIELLO UPS model but made by another manufacturer or when the input sources are not UPS’s

[AS] = Secondaria[PS] = Prioritaria

[AS] = Secondaria[PS] = Prioritaria

[AS] = Secondaria[PS] = Prioritaria

61

Mas

ter

Switc

h

(1) X= 3 in cases of 3-pole switching (3 phases) ; X=4 in cases of 4-pole switching (3 phases + Neutral)

MODELS (1) MTS 100-x MTS 150-X MTS 200-X MTS 250-X MTS 300-X MTS 400-X MTS 600-X

NOMINAL CURRENT (A) 100 150 200 250 300 400 600

INPUT

Nominal voltage - sources S1/S2 380 - 400 - 415 Vac 3-phases with neutral

Input voltage tolerance 180÷264 Vac (selectable)

Switched input phases 3+N (4-pole) - 3 (3-pole)

Nominal frequency 50/60 Hz

Input frequency tolerance +/-10% (selectable)

Distribution compatibility IT, TT, TNS, TNC

OPERATING fEATURES

Transfer typology “Break Before Make” (no sources overlapping)

Available transfer modes Automatic / Manual / Remote

Transfer time for source failure < 4 msec (S1/S2 synchronised)10 msec (S1/S2 not synchronised)

ENVIRONMENTAL

Efficiency at full load (%) > 99%

Noise level at 1 m from front (from 0 to full load) - (dBA)

55 55 55 55 55 55 57

Storage temperature range -10°C to +50°C

Ambient temperature O°C - 40°C

Relative humidity 90% non-condensing

Max. Installation height 1000 m at rated power (-1% power for every 100 m above 1000 m) - Max 4000 m

Standard compatibility EN 62310-1 (safety) EN 62310-2 (electromagnetic compatibility)

ENVIRONMENTAL

Dimensions (hwd) (mm) 685 x 530 x 1500 685 x 580 x 1770 950 x 730 x 1900

Weight (kg) 155 175 205 210 220 240 375

Colour RAL 7035

Index of protection IP 20

62

PREMIUM PRO DIALOG DUAL POWER DIALOG 3 MULTI PLUS

1600 W 2000 W 3000 W 30,000 W

2100 W 3500 W 7000 W 64,000 W

Standby Power Systems

RIELLO UPS uninterruptible power supplies are also designed and built for use in applications such as central supply systems for emergency lighting, security alarms and electro-medical equipment.The EN 50171 standards and other guidelines set down the characteristics and performance levels required from such systems. The main ones are summarised below:

• Up to 3h back-up times• Battery recharge time of under 12h• Galvanically isolated input/output

• High-level diagnostics - preferably from a front mimic panel• Remote interface - normally volt-free contacts• High short circuit current capability

The applications require a continuous power system configured as follows:

• A standard UPS with high capacity battery charger• An isolation transformer option• A remote interface to communicate with other peripherals

Characteristics• Full microprocessor control: for greater reliability and compactness in size• Use of Insulated Gate Bipolar Transistors (IGBT) technology - used in

UPS for over 10 years to optimise performance (such as overloads) and reduce physical sizes

• Advanced communication interface - the units come with a volt-free contact interface and RS232/485 serial interface for communication with a local PC or computer network

• TeleNetGuard remote support service compatible for remote diagnostics and control

• Front panel LCD to display operating status, alarms, measurements and logs

• Option to expand the power and/or reliability through the parallel connection of units - 10kVA models and higher

Options• Communication interfaces: see accessories table for individual models• Isolation transformers

Advanced communication• Multiplatform communication for all operating systems and network

environments, Powershield3 supervision and shut-down software included for Windows 7, 2008, Vista, 2003, XP, Linux, Mac OS X, Sun Solaris and VMware ESX operating systems and other Unix operating systems.

Compliance with LegislationThe Dialog CSS range complies with the relevant European regulations (and national guidelines still in force in some countries) governing such applications.

Dialog CSS

Dialog CSS configurations

Stan

dby

Pow

er S

yste

ms

MODEL

Back-up times of up to 3 hours

POWER LOADS OF POWER UP TO

Back-up times of up to 1 hour

POWER LOADS OF POWER UP TO

63

1. ALwAys PowereD

Diagrams of the various system solutions

2. PowereD From the mAINs 3. emerGeNcy oNLy 4. ALwAys PowereD/emerGeNcy oNLy

A full range of CSS units, from 700VA to 200kVAThe Dialog CSS range units are comprised of the following blocks:

Rectifier: converts the alternating voltage input from the mains power supply or from an alternative source (generator) into direct current voltage.

Inverter: converts the direct current voltage supplied by the rectifier into alternating voltage: in this way the voltage is reconstructed, filtered and stabilised with regard to the input voltage.

By-pass: this allows switching between the inverter and the mains power supply. In “always powered” operating mode the CSS load is always powered from the inverter and is only switched onto the mains via the by-pass circuit in the event of a failure. In “powered from the mains” mode, the load is powered and only switched onto the inverter when there is no power from the mains. In “emergency only” mode the

load is only powered from the inverter in the event of a mains power failure. To deal with switch-on current surges, the inverter has a soft-start feature to limit the current supplied when required. In “always powered/emergency only” two outputs can be used: one always powered (such as for powering computer loads) and one that is only powered when there is no power from the mains (such as for powering emergency lights that by law must switch on within a maximum time of 0.5 seconds from a mains failure).

Batteries: used to feed the inverter output for the legally required time of 3 hours (if there is no generator). The batteries used are generally valve-regulated, lead-acid type, and do not require maintenance or a special installation room as they have very low gas emissions.

Stan

dby

Pow

er S

yste

ms

64

Sinux Inverters

S12 - S24 - S48 - SK1

Sinu

x In

vert

ers

SERIAL PORT

INPUTPROTECTION

INPUT/OUTPUTCONNECTIONS

ELECTRO-MEDICALDEVICES

INDUSTRIAL PLCS

SINUx is a range of 12/24/48/110 Vdc INVERTERS with a 230 Vac 50Hz sinewave output.The output is galvanically isolated thanks to a built in transformer. The inverters are very efficient and have a wide input voltage window, that allows them to be used directly with photovoltaic (solar) panels.

TECHNICAL DETAILS

CHARACTERISTICS• Standard galvanic isolation: the system has a built in transformer to ensure galvanic isolation.• Wide input voltage range: the inverters have a wide input range and are compatible with photovoltaic systems and do not require extra regulation hardware• Full diagnostics: the inverters provide both visual and audible status and diagnostic information• Built-in protection. Protection includes: over and under voltage, reverse polarity, overloads, short circuits and over temperature• Automatic restart: the inverters auto restart when the alarm condition is resolved• Optional bypass• Optional LCD display • Dry contacts interface board: - standard: dc voltage present; dc voltage low - optional: overload; inverter fault; overtemperature • Special versions available on request• Compatible options available on request

INDUSTRIAL PROCESSES

TELECOM-MUNICATION DEVICES

65

S12 120 115

S12 160 161

S12 350 345

S12 460 460

S12 580 575

S12 690 690

S12 800 805

S24 030 30

S24 230 230

S24 320 322

S24 530 529

S24 780 782

S24 920 920

S24 1K1 1150

S24 1K4 1380

S24 1K6 1610

S24 1K8 1840

S24 2K7 2760

S24 3K6 3680

S24 4K1 4140

S48 030 30

S48 100 100

S48 150 150

S48 320 322

S48 460 460

S48 690 690

S48 920 920

S48 1K1 1150

S48 1K4 1380

S48 1K7 1725

S48 2K0 2070

S48 2K5 2530

S48 3K4 3450

S48 4K1 4140

S48 5K0 5060

S48 6K2 6210

S48 6K9 6900

SK1 030 30

SK1 100 104

SK1 150 150

SK1 320 322

SK1 460 460

SK1 690 690

SK1 920 920

SK1 1K1 1150

SK1 1K4 1380

SK1 1K7 1825

SK1 2K0 2070

SK1 2K5 2530

SK1 2K8 2875

SK1 3K5 3450

SK1 4K1 4140

SK1 5K0 5060

SK1 6K2 6210

SK1 6K9 6900

Sinu

x In

vert

ers

MODELS POWER INPUT OUTPUT ENVIRONMENTAL AVAILABLE OPTIONS

(W) Ratedvoltage

Voltage range

Output current (A)

Overload (W) for 5” Weight (kg) Dimensions

(hwd) (mm) By-pass LCDDisplay

Remotecontacts

SINUX INVERTERS S12 (12 Vdc input)

12 V 10.2 - 18 V

0.5 300 13

4U x 19” x 410

• •

0.7 400 15 • •

1.5 600 30 • •

2 800 324U x 19” x 510

• •

2.5 1000 35 • •

3 1200 405U x 19” x 510

• •

3.5 1400 45 • •

SINUX INVERTERS S24 (24 Vdc input)

24 V 19 - 43 V

0.13 50 3 2U x 19” x 160

1 600 13

4U x 19” x 410

• • •

1.4 800 15 • • •

2.3 1000 19 • • •

3.4 1200 30 • • •

4 1600 324U x 19” x 510

• • •

5 2000 35 • • •

6 2500 40

5U x 19” x 510

• • •

7 2800 45 • • •

8 3000 52 • • •

12 4000 60

5U x 19” x 710

• •

16 5000 72 • •

18 6000 80 • •

SINUX INVERTERS S48 (48 Vdc input)

48 V

39 - 60 V

0.13 50 3

2U x 19” x 1600.45 130 3.5

0.65 230 4

1.4 800 13

4U x 19” x 410

• • •

2 1000 15 • • •

3 1200 19 • • •

39 - 80 V

4 1500 30 • • •

5 2000 324U x 19” x 510

• • •

6 2500 35 • • •

7.5 3500 40

5U x 19 ”x 510

• • •

9 4000 45 • • •

11 4500 52 • • •

15 6000 60

5U x 19” x 710

• •

18 7000 66 • •

22 8000 72 • •

27 9000 78 • •

39 - 60 V 30 10000 83 • •

SINUX INVERTERS SK1 (110 Vdc input)

110 V 88 - 145 V

0.13 50 3,5

2U x 19” x 1600.45 130 4

0.65 180 4

1.4 800 13

4Ux 19” x 410

• • •

2 1000 15 • • •

3 1200 19 • • •

4 1500 30 • • •

5 2000 324U x 19” x 510

• • •

6 2500 35 • • •

7.5 3500 40

5U x 19” x 510

• • •

9 4000 45 • • •

11 4500 50 • • •

12.5 5000 55 • • •

15 6000 60

5U x 19” x 710

• •

18 7000 66 • •

22 8000 72 • •

27 9000 78 • •

30 10000 83 • •

Product characteristics can be customised to meet client specifications.

66

Connectivity

Soft

war

e an

d Ac

cess

orie

s

67

Powershield3

Soft

war

e an

d Ac

cess

orie

s

• Sequential and priority-based shutdown: PowerShield3 provides unattended shut-down of single and networked PCs, saving any active work and the most widely used applications Windows. Users can define their own shutdown procedures and establish the order in which critical computers (such as servers) are to be powered down

• Multi-platform compatibility: PowerShield3 uses the TCP/IP communications protocol to achieve standardised management and monitoring across the widest possible range of platforms. This makes it possible to monitor computers with different operating systems from a single console, for example monitoring a UNIX server from a PC with Windows and also connecting to UPS located in different geographical areas using dedicated networks (intranets) or the Internet

• Event scheduling: PowerShield3 users can program their own shutdown procedures, detailing power-off and power-up scenarios to increase system safety and, equally important, power economy

• Messages management: PowerShield3 keeps users constantly informed about the status of their local and network UPS, and environmental sensors. A list can be defined of users who should receive e-mail messages, faxes and SMS when faults or sudden mains power supply failures occur

• Integrated SNMP agent: PowerShield3 features an integrated SNMP agent for UPS management which can send all the information required and generate traps using the RFC 1628 MIB standard and environmental sensors. This

All the trademarks indicated are the property of their respective owners.

PowerShield3 can be downloaded free of charge from www.riello-ups.com

Communication Software

feature makes it possilbe to manage the UPS in compatible SNMP management stations such as HP Open View, Novell Managewise and IBM NetView

• Wap server integrated: PowerShield3 allows the user to monitor a UPS through WAP mobile phone

• Security, easy to use and connect, communication is password protected to ensure UPS system security. Using the new discovery/browsing function, all the RIELLO UPS connected to a protected computer or LAN can be displayed in a list format. In the absence of a LAN connection, support is provided for modem-based communication.

• Windows 2000, 2003 Server, XP, Vista, 2008 Server, 7, on X86, X86_64 and IA64 processors

• Linux on X86, X86_64 and IA64 processors• Novell Netware 3.x, 4.x, 5.x, 6• Mac OS X• The most common UNIX operating systems such as: IBM AIX, HP, SUN Solaris

INTEL and SPARC, SCO Unixware and Open Server, Silicon Graphics IRIX, Compaq Tru64 UNIX and DEC UNIX, Open BSD UNIX and FreeBSD UNIX, NCR UNIX

• HP OPEN VMS• VMWare ESX, VSPHERE

PowerShield3 provides efficient, user-friendly UPS management using bar chart displays to show major operational information such as the input voltage, UPS load % and batteries charge %. The software also provides detailed information on fault conditions and UPS operating characteristics. PowerShield3 has been developed with a client/server architecture that makes it flexible and easy to use, and provides multi-lingual and on-line support.

Operating systems supported

Characteristics

GRAPHIC MONITORING OF UPS AND ENVIRONMENTAL SENSORS STATUS PowerShield3 is a simple but powerful rIeLLo UPs management tool. there are various graphic versions for all the operating systems.

DETAILED UPS PARAMETER DISPLAY AND ENVIRONMENTAL SENSORSPowerShield3 provides all the information required for first level diagnostics.

EVENTS LOG AND GRAPHICAL DISPLAYAll changes in UPs operating status are logged and displayed in a graphical format from which the user can monitor trends in the mains electrical parameters monitored.

PROGRAMMING OF UPS PARAMETERS the user can select several options remotely: turn the UPs on or off, restart after a power loss and instigate a battery test.

GRAPHIC MONITORING OF UPS STATUS VERSION FOR MAC OS x rIeLLo UPs PowerShield3 software is the only UPs control and shut-down software running under macintosh with a client-server cross platform architecture. It allows integration in tcP/IP networks with windows, Novell, IBm os/2 and the most widely used UNIX operating systems. PowerShield3 supports the Netman Plus series of network agents and provides multi-language support.

BLOCK AND FUNCTIONAL DIAGRAMSPowerShield3 also displays the UPs in block format providing the user with information regarding operating status.

NOTIFICATION OF ALARMS VIA E-MAIL, SMS, FAx AND VOICEPowerShield3 can be configured to forward alarm messages automatically via e-mail, sms, fax and voice.

68

PowerNETGuard

1.

1. 2.

1. Netman

Netman

Netman

PowerNETGuard software centralises UPS management using network interface (SNMP) communications. It is ideal for Data Centre managers and medium to large sized networks. PowerNETGuard uses the RFC1628 standard Management Information Base (MIB) and ensures standardised UPS management wherever they are located.

Supervision software

• Centralised control of remote UPS via Ethernet with SNMP protocol• Multiple-level display of geographical areas, building plans, maps, etc.• Multi-user access with various levels of security• Compatible with Netman Plus and RFC1628 standard network

interface (SNMP)• Graphs of physical input and output values stored and backed up to file• Alarm notification via e-mail and SMS• Wap Server• Operating systems supported: Windows (98, ME, NT, 2000, 2003,

XP and Vista), Linux, MacOSX, Solaris 8, 9 and 10 and Silicon Graphics IRIX

Centralised control of remote UPS

Characteristics

Soft

war

e an

d Ac

cess

orie

s

network agent

69

NetMan 102 Plus

NetMan 101 PlusNetwork agent

Network agent

Soft

war

e an

d Ac

cess

orie

s

The NetMan Plus network agent allows UPS management across a LAN using any of the main network communication protocols - TCP/IP, HTTP and network interface (SNMP). NetMan Plus enabled UPS integrate easily into medium and large sized networks and provide reliable communications between the UPS and management systems employed.

The NetMan Plus network agent allows UPS management across a LAN using any of the main network communication protocols - TCP/IP, HTTP and network interface (SNMP). NetMan Plus enabled UPS integrate easily into medium and large sized networks and provide reliable communications between the UPS and management systems employed.

• Configured via TELNET or a serial terminal• Compatible with PowerShield3 and PowerNETGuard control software• Supports the network interface (SNMP) standard communication protocol with proprietary RFC 1628 and MIB

• SNMP with RFC 3433 to manage the environmental sensors• Integrated Web server for browser-based display• TeleNetGuard modem compatible• Firmware upgradeable through the serial port• E-mail sent through SMTP server

Characteristics

• Configured via TELNET or a serial terminal• Compatible with PowerShield3 and PowerNETGuard control software• Supports the network interface (SNMP) standard communication protocol with proprietary RFC 1628 and MIB

• SNMP with RFC 3433 to manage the environmental sensors• Integrated Web server for browser-based display• TeleNetGuard modem compatible• Firmware upgradeable through the serial port• E-mail sent through SMTP server

Characteristics

70

Multicom 301/302

Netman Netman

EnvironmentalSensorsThe Netman environmental sensors monitor and record environmental conditions as well as activities in protected areas and at the premises where the UPS is installed. The sensors provide extensive management and control, triggering cooling fans and locks in response to changes in temperature and humidity. Remote monitoring and control can be provided via the internet, SNMP and the Riello PowerShield³ software. NetMan Plus can support up to 6 separate sensors. The environmental sensors are easy to install and do not need a separate external power supply.

The following sensors are available:- Sensor for temperature: -55 +125 °C- Sensor for temperature: -55 +125 °C and humidity: 0- 100%- Sensor for temperature: -55 +125 °C and digital I/O: 0-12Vdc. In, 1A max Out 48Vdc

APPLIcAtIoN DIAGrAm

temperature sensor

temperature sensor

temperature sensor

Air conditionersmoke detector

APPLIcAtIoN DIAGrAm

Protocol Converter

• Port configuration for MODBUS/JBUS as RS232 or RS485• Management of two independent serial lines• Suitable for Building Management System (BMS) integration

• LED communication flow indicators• Firmware upgradeable through the serial port

Characteristics

The MultiCOM 301/302 protocol converter may be used to monitor the UPS using the MODBUS/JBUS protocol on RS232 or RS485 serial lines. It can also manage a second independent RS232 serial line that can be used to connect to other devices such as the Netman 101 or a PC using PowerShield3 software.

Soft

war

e an

d Ac

cess

orie

s

71

Multicom 351/352

Multicom 362

Multicom 372

Serial / USB port

MultiCOM 362 provides a UPS with an additional RS232 serial interface or USB port. The USB port allows the UPS to communicate with Apple Macintosh computers as well as Windows and Linux operating systems.

• Compatible with USB 1 or 2• Compatible with PowerShield3

Characteristics

Serial link duplexer

The MultiCOM 351/352 is a serial duplexer that allows two devices to be connected to a single serial port on a UPS.It can be used where numerous serial connections and multiple UPS polling are required, and is ideal for LAN networks with a firewall.

• Cascading configuration giving a maximum of 4 serial communication ports

• LED communication flow indicators• Firmware upgradeable through the serial port.

Characteristics

Serial / EPO port

MultiCOM 372 provides a UPS with an additional RS232 serial interface port. The card has Emergency Power Off (EPO) and Remote Shut Down (RSD) inputs with terminal connections.

• EPO and UPS shutdown interface• 12Vdc 80mA contact option

Characteristics

Soft

war

e an

d Ac

cess

orie

s

72

I/O

Multicom 382

Multi I/O

Contacts / EPO board

MultiCOM 382 provides a set of relay contacts to provide UPS alarm and status indication.The contacts are connected through terminal connections. Signal contacts include Emergency Power Off (EPO), Remote Shut Down (RSD), On Battery, On Bypass, Alarm and Low battery. The contacts are change over or normally open.

• Max. 3A current at 250Vac• Signal contact customisation

Characteristics

Protocol converter

Multi I/O has configurable input and output signal contacts to allow UPS integration with control systems. It can be used to connect two devices to a single UPS serial communication port. It can also communicate using the MODBUS/JBUS protocol on RS485 lines.

• 8 analog/digital inputs• 8 relay outputs to monitor UPS and mains status• It can control two independent RS232/RS485 serial lines to monitor the UPS and its operating states using the MODBUS/JBUS protocol• Firmware upgradeable through the serial port

Characteristics

The I/O expansion card, for the Master Plus range, is equipped with:• 6 outputs with voltage-free NC/NO contacts (250V/5A), electrically isolated from each other and from other circuits• 2 self-powered inputs

Each output or input can be configured with different meanings, via the relative menu.

Expansion card

73

Multi Panel

Multicom 401

Kit AS400 / i-Series

Soft

war

e an

d Ac

cess

orie

s

Protocol converter

The Multicom 401 is an accessory with which you can connect a UPS to a Profibus DP network. With this device management and monitoring of the UPS can be integrated in a control system based on one of the field buses most widely used in industry for communication between control/automation systems and distributed I/O.

• PROFIBUS DP-V1 Protocol• Configurable address from 0 to 99

• Profidrive V2 PP05• Configurable baud rate from 9.6 kBit/s to 12 MBit/s• Led reporting the communication flow

Characteristics

Communication Kit

The IBM AS/400 has a single-level memory management feature that makes it compulsory for the system to be shutdown in a controlled and orderly manner. Without UPS protection an AS/400 is not protected from mains failures. A momentary loss of power can cause hardware damage, data corruption and a lengthy reboot period.The RIELLO UPS AS/400 interface kit allows a UPS to be connected to the AS/400 to initiate an orderly system shutdown on mains failure.

• Compatible with all AS/400 systems• Supports all the RIELLO UPS ranges

Characteristics

MultiPanel is a remote monitoring device that can provide a detailed UPS status overview in real time. It is compatible with all Riello UPS and can display values for UPS specific input and output supplies, and battery set measurements.MultiPanel has a high-definition graphical display and can report in 7 languages: English, Italian, German, French, Spanish, Russian and Chinese. It has 3 independent serial ports, one of which allows for UPS monitoring via the MODBUS/JBUS protocol (on either an RS485 or RS232 serial line). The others can be used with devices such as the Netman 101 Plus or a PC running PowerShield3 software.

• Graphical high definition LCD panel• Three independent serial connections

• Compatible with most BMS management programs• Communications flow LED status indicator• Serial port upgradeable firmware

Characteristics

Remote Monitoring Panel

74

MODBUS

PROfIBUS

Point-to-point connectionswith serial lines

Connections with field buswith serial linesC

onne

ctiv

ity: s

ome

solu

tions

Connectivity: some solutions

SoftwarePowershield3

RS232

USB

SoftwarePowershield3

RS232

USB

SoftwarePowershield3

RS232

USB

Multicom 362

LocalLocation

LocalLocation

LocalLocation

free

free

full license

management PC

RS485 MODBUSMulticom 301/302

PLCMulticom 301/302

Multicom 301/302

LocalLocation

management PC

Multicom 401

Profibus DPPLC

Multicom 401

75

TCP/IP Ethernet connections WAN

Connection with PLC to contacts

TCP/IP Ethernet connections LAN/WAN

Con

nect

ivity

: som

e so

lutio

ns

Netman 101/102 plus

Netman 101/102 plus

Netman 101/102 plus

Netman 101/102 plus

SWITCH

SWITCH

internet SoftwarePowerNetGuard

RemoteLocation

WAN

Netman 101/202 plus

Netman 101/202 plus

Netman 101/202 plus

SWITCH LAN

WAN

SoftwarePowerNetGuard

SoftwarePowershield3

Server

RemoteLocation

RemoteLocation

full license

SoftwarePowershield3

free

internet

RS232

USB

management PCMulticom 372

PLC LocalLocation

76

IPLUG 1 •

IDIALOG 1 1* •

DIALOG VISION 1 1 1 • •

PREMIUM PRO 1 1 1 • •

PREMIUM DUAL 1 1 1 • •

DIALOG DUAL 1 1 1 • • •

POWER DIALOG 3 1 1 1 • • •

MULTI DIALOG 2 1 • •

MULTI PLUS 1 1 3 • •

MASTER PLUS / HIP 2 2 • •

• • • • • • • • • • • • • • •

• • • • • • • • • • • • • • •

• • • • • • • • • • • • • • •

• • • • • • • • • • • • • • • •

• • • • • • • • • • • • • • • •

• • • • • • • • • • • • •

• • • • • • • • • • • • • • • •

• • • • • • • • • • • • • •

USB

Por

t

RS23

2 po

rt

SLOT

UPS

Mod

em M

anag

emen

t

Mic

roso

ft Pl

ug &

Pla

y

Powe

rShi

eld3

Net

Man

101

plu

s

Net

Man

102

plu

s

Mul

tiCO

M 3

51

Mul

tiCO

M 3

52

Mul

tiCO

M 3

01

Mul

tiCO

M 3

02

Mul

tiCO

M 3

62

Mul

tiCO

M 3

72

Mul

tiCO

M 3

82

Mul

tiCO

M 4

01

Mul

ti I/

O

Expa

nsio

n I/

O

Mul

tiCO

M 4

01

AS/4

00 K

it

Powe

rNet

Guar

d

Tele

Net

Guar

d

Mul

ti Pa

nel

Soft

war

e an

d Ac

cess

orie

s

Standard fittings Software and optional accessories

Compatibility table

77

MBB10A - MBB16AMBB32A

MBB100A

Multi Pass 16 / 16-R

LOAD

MAINS

OUT UPS

MAINS

LOAD

SWIN

SWOUT

SWMB

AUX

AUX

REMOTE MAINTENANCEByPASS

(NORMAL CLOSE CONTACT)

TO UPS INPUTor UPS ByPASS INPUT

FROM UPSByPASS

Maintenance Bypass

Available only in one version which allows manual bypass operations on any 10 to 20kVA single phase UPS and 10 to 40kVA three phase UPS. The device comes with three circuit breakers as shown in the attached diagram, so as to ensure complete isolation of the UPS during maintenance or removal operations, whilst guaranteeing continuous power supply to the loads.The device has a microswitch for connection to the appropriate UPS input, which signals closure of the manual bypass, in order to prevent energy being supplied simultaneously from the manual bypass and the inverter. RIELLO UPS offers a wide range of external bypasses and static switches for UPS models up to 800kVA and for parallel systems up to 6.4MVA.

Maintenance Bypass

This is available in 10, 16 and 32 Amp models, and allows a UPS unit up to 6kVA to be safely powered down for maintenance/removal, without any disruption in the power supplied to the load. Both versions are supplied with a wall mount metal bracket.

Manual Bypass

Multi PASS is a maintenance bypass to allow a UPS to be powered down and removed for service without disruption to the connected load(s).Multi PASS has both manual and automatic transfer functions. If the UPS is accidentally disconnected or fails any load(s) connected to Multi PASS are automatically transfered to the mains supply. Multi PASS is available in wall mounted or 19” rackmount formats. RIELLO UPS supplies a wide range of external maintenance bypasses and switchgear for their UPS up to the 800kVA Master Plus and for parallel systems up to 6.4MVA.

• Wall or rackmount versions• Back-feed protection

• Manual and automatic transfer functions• Mains power present LED indicator• IEC, UK, Schuko and hard wired connected options

Characteristics

MULTI PASS 16WALL MOUNT VERSION

REAR PANEL MULTI PASS 16-RRACKMOUNT VERSION

By-p

ass

Acce

ssor

ies

78

[email protected]

Services and consultancy

UPService organises regular TECHNICAL TRAINING COURSES for UPS operators and installers.

TEC is the RIELLO UPS pre-sales advisory service.Our TEC (Technical Energy Consultant) experts have been working in the power sector for years, and come from backgrounds with technical experience in industry and power plants.

CONSULTANCY ON STANDARDSTEC personnel can provide advice on the relevant standards affecting:• RIELLO UPS product ranges• Batteries• Installation• Applications - such as emergency lighting, security and electro-medical

WORK TOOLSTEC training and information is provided in the form of:• UPS sizing• Official technical guides• Installation and specification manuals• TEC newsletters• Technical specifications

TECHNICAL CONSULTANCYTEC personnel can provide advise and guidance on the selection, sizing and installation of RIELLO UPS products.

SUPPORT IN DESIGNTEC personnel can provide assistance in the design of a UPS system to completely satisfy customer specifications, including bespoke designs.

HELP DESKTEC is available 24-7 around the world and may be reached by phone, fax or e-mail to answer your requests immediately.

UPService, our technical assistance facility uses highly trained engineers to provide a reliable and competent technical support and after-sales service. UPService can provide customers with:

• A dedicated CALL CENTRE for connection to the UPService organisation.UPService personnel are always available and ready to provide advice and assistance regarding UPS installation, maintenance, fault finding and repair.

• The free SWAP assistance service.

• ON SITE a site based service for larger UPS that cannot be transported back to the UPService facility, either inside or outside warranty. A fast repair on site is guaranteed through the use of state-of-the-art UPS technology and the professionalism of the UPService personnel and Authorised Assistance Centres. UPService guarantees that failed parts are replaced with functioning ones, tested and updated in order to maintain the safety, reliability and operating characteristics of the UPS.

• On request, UPService can provide assistance during installation and initial startup of the UPS and train on-site personnel. UPService engineers can also verify site suitability, analyse and advise on rental solutions and disconnect and relocate equipment.

• MAINTENANCE CONTRACTS can be provided by UPService to minimise response times and repair costs. Contracts range from periodic inspections to comprehensive cover including labour and materials.

• The TeleNetGuard software package provides remote 24-7 UPS supervision. TeleNetGuard can interrogate RIELLO UPS connected to a local telephone line to check on their operating logs and system status. Should the UPS report an alarm condition, the UPService Call Centre is immediately notified and a dedicated customer response activated. Routine site reports can be sent automatically to customer personnel.

Pre-sales consultancy Technical support and services

Operating Offices

UKrIeLLo UPs LtdUnit 50 - clywedog road Northwrexham Industrial estate - wrexham LL13 9XNtel.: +44 (0)1978 729 297 - Fax: +44 (0)1978 729 290www.riello-ups.co.uk / [email protected]

coNstANt Power servIces LtdUnit 3 - trust Industrial estate, wilbury wayhitchin, herts, sG4 0UZtel.: +44 (0)1462 422 955 - Fax: +44 (0)1462 422 754www.cps4ups.co.uk / [email protected]

DEUTSCHLANDrIeLLo UPs Gmbhsiemensstr. 1221465 reinbek Bei hamburgtel.: +49 (0)40 727 57-06 - Fax: +49 (0)40 727 57-189www.riello-ups.de / [email protected]

fRANCErIeLLo oNDULeUrs s.a.r.l.Direction,6 rue de la mare Neuvecourcouronnes - 91021 evry cedextel.: +33 (0)1 60 875454 - Fax: +33 (0)1 60 875450www.riello-onduleurs.com - [email protected]

sALes sUDsiège, Parc d’Activité de Limonest, Bâtiment 2 – hall Arue des vergers 69760 Limonesttel.: +33 (0)4 72 177108 - Fax: +33 (0)4 78 351422www.riello-onduleurs.com - [email protected]

ESPAÑArIeLLo eNerDAtA s.l.P.I. Prado del espino c/vidrieros, 428660 Boadilla del monte, madridtel.: +34 (0)91 63 33 000 - Fax: +34 (0)91 63 21 793www.enerdata.es / [email protected]

rIeLLo tDL s.l.Apartado de correos 137, c/Berguedà, 6 bis08211 castellar del vallès, Barcelonatel. (34) 902 026 654 - Fax. (34) 93 714 65 62www.riello-tdl.com / [email protected]

rIeLLo eLettroNIcA - soLAr techNoLoGIesc/ Pintor sorolla, 19 - 7a 13a46002 valencia esPANAtel. +34 963 52 52 12 - Fax +34 963 52 46 99www.riellosolar.com - [email protected]

CHINAriello UPs (Asia) co., Ltd28F, No. 500 Fute Dong er road, waigaoqiao Free trade Zone200131 shanghai, PeoLPLe’s rePUBLIc oF chINAtel : +86-21-50464748 - Fax: +86-21-50464648www.riello-ups.com - [email protected]

ASIA PACIfICrPs rePreseNtAtIve oFFIceNo.9, shenton way #04-08068813 singaporewww.riello-ups.com - [email protected]

ITALIALEGNAGO, Head Officeviale europa, 7 ZAI 37045 Legnago (vr) tel.: +39 0442 635811Fax: +39 0442 629098 www.riello-ups.com [email protected]

MiLANOvia somalia, 2020032 cormano (mI) tel.: +39 02 61541711Fax: +39 02 [email protected]

ROMAvia Fosso della magliana, 34/G00148 romatel.: +39 06 65192125Fax: +39 06 [email protected]

80

OfficialSponsor

General Catalogue01. 2010

CATG

ENX0

110R

UGB

I

n th

e in

tere

sts

of p

rodu

ct im

prov

emen

t Rie

llo U

PS re

serv

es th

e rig

ht to

cha

nge

spec

ifica

tions

with

out n

otice

.