Upload
others
View
16
Download
0
Embed Size (px)
Citation preview
• Photoelectric Sensors
• Displacement Sensors
• Vision Systems
• Safety Sensors
• Safety Switches
• Safety Relays
• Proximity Sensors
• Rotary Encoders
• Pressure Sensors
GENERAL CATALOGUE 2004/2005
Sensing & Safety
Advanced Industrial Automation
Cat.No. F502-EN2-03A SEN
E-1
Proximity Sensors
Cylindrical
Standard
E2A E-6
E2E E-22
E2EL E-44
TL E-52
Antispatter E2EQ E-56
Chemical Resistance E2FQ E-64
Rectangular
Subminiature E2S E-68
Flat TL-W E-76
Standard TL-N E-84
Capacitive
Liquid Level E2K-L E-92
Long Distance E2K-C E-98
Flat E2K-F E-104
Chemical Resistance E2KQ-X E-108
Peripheral Equipment
Accessories Y92@ E-111
E-2 Proximity Sensors
Omron’s E2A series of proximity sensors is designed to provide highly reliable
detection of ferrous metal objects. What’s unique about these sensors is their
construction; Omron has developed a fully automated process that enables
these sensors to be produced in a modular way, and which guarantees the
highest level of reliability available. And because these sensors are modular in
design, Omron can satisfy customer application requirements faster and cost-
effectively!
Best-in-class sensors,modular for total solutions!
Housed in metal cylinders, the E2A sensors are
available in a full range of standard sizes (M8, M12,
M18 and M30, both long and short-barrelled) and with a full
range of standard connections (pre-wired, M8 and M12
connectors). Their tough construction and reliability make
these sensors ideal for use in diverse applications such as
automotive manufacturing, packaging process machines,
commercial vehicles and materials handling.
E-3E2A/E2E/E2EL/TL
E2A
/E2E
/E2E
L/T
L
Double sensing distance increases reliability… E2A proximity sensors deliver a double distance sensing
range capability as standard. This helps to protect against me-
chanical damage from the machine and moving parts while al-
lowing the E2A to deliver very reliable sensing, even with a
build-up of contamination on the sensing face.
… and saves space! The increased sensing distance of these switches enables
you to choose a smaller sized model for the same sensing ap-
plication! This is very beneficial in machine construction
where component size reduction is an important factor.
Fully automated production processOmron has developed a unique, fully automated process
for producing the E2A series that offers many benefits. The
sensors are constructed in a modular fashion from four main
sections – the sensing module, the output module, the body
and the connector. By doing this Omron can adapt the product
quickly to suit customised specifications. Product calibration
is much higher, tolerances are much tighter, and the manufac-
turing process is much more efficient. All of which results in a
very high quality, cost-effective product!
LED indicator for easy mounting Each E2A proximity sensor features a LED-mounting facility
that enables you to install the sensor quickly, and within the
optimal range of the sensing distance.
Reliability – part of the processAs a pioneer of proximity sensor technology, Omron’s product
reliability is unrivalled. All E2A sensors are designed to handle
temperature conditions ranging from –40°C to +70°C, and
their ability to withstand temperature extremes in water en-
ables them to easily meet IP67 specifications.
Innovation – an ongoing processOmron’s unique modular construction process has opened up
many new possibilities. The company is developing sensors
with triple-distance capabilities, aluminium barrels, sensors
that connect directly to power lines, and teflon-coated models
for use in hazardous environments. All of this is possible with
Omron’s unique modular construction process!
An environmentally aware companyOmron prides itself on environmental awareness.
Lead-free soldering is already a state-of-the-art
soldering process for Omron. In addition, packag-
ing material is reduced to a minimum and can be
recycled easily.
Features at a glance!
• Standard double sensing distance
• Full range of standard sizes
(M8, M12, M18, M30, both long and short barrel)
• Full range of standard connections
(pre-wired, M8 and M12 connector)
• Modular construction enables the following specifica-
tions to be customised: DC 2-wire output, cable
length, cable construction (using various materials
like PVC, PUR,
Halon-free cabling, and in different strands), voltage
range, sensing distance, housing size and material
• Laser marking for durable identification
-40
-20
0
20
40
60
80
time
tem
pera
ture
(ºC
)
•Heat shock test- 50 cycles
•IP67 Water proof- 20 cycles, 1 hour each temperature, transfer time <2min
•IP67 standard test- 30 min room temperature
Even standard proximity sensors have to pass the heat-shock and waterproof test. After 50 cycles of temperature variation from –40°C to +70°C, the sensor is immersed alter-nately in ice-cold and hot water for 20 cycles. Their ability to handle such severe temper-ature stress proves that these proximity sensors can easily meet the IP67 test.
E-4 Proximity Sensors
Cylindrical Proximity Sensors Selection Guide
Note: 1 .M 30 non-shielded models with double sensing distance and short barrelsl cannot be mounted due to the necessary separation distance form the surroundingmetal. Standard sensing models are thus available.
Connection check by means of a DC 2-wire proximity sensor and PLC (programmable logic controller)(Required Conditions)Connection to a PLC is possible if the specifications of the PLC and the Proximity Sensor satisfythe following conditions. (The meanings of the symbols are given below.)1. The ON voltage of the PLC and the residual voltage of the Proximity Sensor must satisfy the following.
VON VCC - VR
2. The OFF current of the PLC and the leakage current of the Proximity Sensor must satisfy the following.IOFF ILEAK
(If the OFF current of the PLC and the control output (IOUT) of the Proximity Sensor must satisfy the following.)IOUT (min) ION IOUT (max)
3. The ON current of the PLC will vary, however, with the supply voltage and the input impedance used as shown in the following equation.
ION = (VCC-VR-VPC)/RIN
(Connection example)In this example, the above conditions are checked for such case that the PLC model is the C200H-ID212, the proximity sensor model is E2E-X7D1-N, and the supply voltage is 24 VDC.1. VON (14.4 V) Vcc (20.4 V) - VR (3 V) 17.4 V : OK2. IOFF (1.3 mA) ILEAK (0.8mA) : OK3. ION = (VCC (20.4 V) - VR (3 V) - VPC (4 V)) / RIN (3 k) 4.5mA
Whereas, IOUT (min) (3 mA) = ION (4.5 mA) : OK.
Size
External diameter Sensing distance
Size is determinedfrom an mounting space.
Sensing distance changes with size,the existence of a shield, and powersupply types.
Type SizePower
typeModel
ProductFamily
Sensing distance (mm)
DC 3-wire E2EE2EE2EE2ELTLE2AE2EE2EE2AE2EE2EE2AE2EE2EE2AE2EE2EE2ELTLE2AE2AE2AE2AE2EE2EE2AE2EE2EE2AE2EE2E
Ø 4 mm
Shielded
Unshielded
It is hard to be influencedof surrounding m
etals.D
etection
distan
ce is lon
g.
DC 3-wireM 5DC 3-wireØ 5.4 mmDC 3-wireØ 6.5 mmDC 3-wireØ 8 mmDC 3-wireM 8DC 2-wireAC 2-wireDC 3-wireM 12DC 2-wireAC 2-wireDC 3-wireM 18DC 2-wireAC 2-wireDC 3-wireM 30DC 2-wireAC 3-wireDC 3-wireØ 6.5 mmDC 3-wireØ 8 mmDC 3-wireM 8DC 2-wireAC 2-wireDC 3-wireM 12DC 2-wireAC 2-wireDC 3-wireM 18DC 2-wireAC 2-wireDC 3-wireM 30DC 2-wireAC 2-wire
0.8 1 1.5 2 3 4 5 7 8 10 14 15 16 18 20 30
1 1
VON: PLC ON voltage (14.4 V)ION: PLC ON current (typ.7 mA)IOFF: PLC OFF current (1.3 mA)RIN: PLC input impedance (3 k)VPC: PLC internal remains voltage (4 V)VR: Output residual voltage of Proximity Sensor (3 V)ILEAK : Leakage current of Proximity Sensor (0.8 mA)IOUT: Proximity sensors control output (3 to 100 mA)VCC: supply voltage (PLC: 20.4 to 26.4 V)The values in parentheses are for the following PLC model and Proximity Sensor model.PLC: C200H-ID212Proximity Sensor: E2E-X7D1-N
E-5E2A/E2E/E2EL/TL
E2A
/E2E
/E2E
L/T
L
Power/Output
Operating Environment
Maintenance
Trouble curtailment Mounting to a movable part
Easy replacement
Inventory reduction
Wide range of operating temp
It is hard to be influenced of surrounding metals
Mutual interference prevention
Miswiring measures
Early detection
AC
DCCan DC 2-wiremodel be used? DC 2-wire model
E2E-X#D#
DC 3-wire modelE2A
AC 2-wire modelE2E-X#Y#
Connector typeE2E-X#D#-M1 (G)E2A-#M#
E2E-X#Y#-M1
Bending resistance cable modelE2AE2E-X#D1-R
Difference frequency model (NO type only)E2AE2E-X##15
DC 2-wire modelE2E-X#D#
DC 3-wire modelE2A
DC 2-wire model, No polarityE2E-X#D1-M1J-T
Diagnostic modelE2E-X#D1S
-40 to +85˚CE2E-X#Y#
-40 to +75˚CE2AE2E-X#D#
E2E-X#T1
Shielded
DC 2-wire modelE2E-X#D#
NPN/PNP compatible
Short circuit protection
No polarity
Yes
No
* Interface conditions with load are checked.
Cable bending
E-6 Proximity Sensors
Cylindrical Proximity Sensor
E2A• Ensures a sensing distance
approximately 1.5 to 2 times larger than that of any conventional OMRON Sensor.
• Problems such as the collision of workpieces are eliminated.
• Full range of standard sizes (M8, M12, M18 and M30; both long and short barrels)
• Modular construction simplifies customization.
Safe Mounting with Greater Sensing Distance
Ordering Information
Size Sensing distance Connection Body
materialThread length
(overall length)Output
configuration Operation mode NO Operation mode NC
M8 Shielded 2.0 mm
Pre-wired Stainless steel
27 (40)PNP E2A-S08KS02-WP-B1 2M E2A-S08KS02-WP-B2 2M
NPN E2A-S08KS02-WP-C1 2M E2A-S08KS02-WP-C2 2M
49 (62)PNP E2A-S08LS02-WP-B1 2M E2A-S08LS02-WP-B2 2M
NPN E2A-S08LS02-WP-C1 2M E2A-S08LS02-WP-C2 2M
M12 connector
Stainless steel
27 (43)PNP E2A-S08KS02-M1-B1 E2A-S08KS02-M1-B2NPN E2A-S08KS02-M1-C1 E2A-S08KS02-M1-C2
49 (65)PNP E2A-S08LS02-M1-B1 E2A-S08LS02-M1-B2
NPN E2A-S08LS02-M1-C1 E2A-S08LS02-M1-C2
Brass
27 (43)PNP E2A-M08KS02-M1-B1 E2A-M08KS02-M1-B2
NPN E2A-M08KS02-M1-C1 E2A-M08KS02-M1-C2
49 (65)PNP E2A-M08LS02-M1-B1 E2A-M08LS02-M1-B2NPN E2A-M08LS02-M1-C1 E2A-M08LS02-M1-C2
M8 connector (3-pin)
Stainless steel
27 (39)PNP E2A-S08KS02-M5-B1 E2A-S08KS02-M5-B2
NPN E2A-S08KS02-M5-C1 E2A-S08KS02-M5-C2
49 (61)PNP E2A-S08LS02-M5-B1 E2A-S08LS02-M5-B2
NPN E2A-S08LS02-M5-C1 E2A-S08LS02-M5-C2
E-7E2A
E2A
M8 Non-shielded 4.0 mm
Pre-wired Stainless steel
27 (40)PNP E2A-S08KN04-WP-B1 2M E2A-S08KN04-WP-B2 2M
NPN E2A-S08KN04-WP-C1 2M E2A-S08KN04-WP-C2 2M
49 (62)PNP E2A-S08LN04-WP-B1 2M E2A-S08LN04-WP-B2 2M
NPN E2A-S08LN04-WP-C1 2M E2A-S08LN04-WP-C2 2M
M12 connector
Stainless steel
27 (43)PNP E2A-S08KN04-M1-B1 E2A-S08KN04-M1-B2NPN E2A-S08KN04-M1-C1 E2A-S08KN04-M1-C2
49 (65)PNP E2A-S08LN04-M1-B1 E2A-S08LN04-M1-B2
NPN E2A-S08LN04-M1-C1 E2A-S08LN04-M1-C2
Brass
27 (43)PNP E2A-M08KN04-M1-B1 E2A-M08KN04-M1-B2
NPN E2A-M08KN04-M1-C1 E2A-M08KN04-M1-C2
49 (65)PNP E2A-M08LN04-M1-B1 E2A-M08LN04-M1-B2NPN E2A-M08LN04-M1-C1 E2A-M08LN04-M1-C2
M8 connector (3-pin)
Stainless steel
27 (39)PNP E2A-S08KN04-M5-B1 E2A-S08KN04-M5-B2
NPN E2A-S08KN04-M5-C1 E2A-S08KN04-M5-C2
49 (61)PNP E2A-S08LN04-M5-B1 E2A-S08LN04-M5-B2
NPN E2A-S08LN04-M5-C1 E2A-S08LN04-M5-C2
M12
Shielded 4.0 mm
Pre-wired Brass
34 (50)PNP E2A-M12KS04-WP-B1 2M E2A-M12KS04-WP-B2 2MNPN E2A-M12KS04-WP-C1 2M E2A-M12KS04-WP-C2 2M
56 (72)PNP E2A-M12LS04-WP-B1 2M E2A-M12LS04-WP-B2 2M
NPN E2A-M12LS04-WP-C1 2M E2A-M12LS04-WP-C2 2M
M12 connec-tor Brass
34 (48)PNP E2A-M12KS04-M1-B1 E2A-M12KS04-M1-B2
NPN E2A-M12KS04-M1-C1 E2A-M12KS04-M1-C2
56 (70)PNP E2A-M12LS04-M1-B1 E2A-M12LS04-M1-B2NPN E2A-M12LS04-M1-C1 E2A-M12LS04-M1-C2
Non-shielded 8.0 mm
Pre-wired Brass
34 (50)PNP E2A-M12KN08-WP-B1 2M E2A-M12KN08-WP-B2 2M
NPN E2A-M12KN08-WP-C1 2M E2A-M12KN08-WP-C2 2M
56 (72)PNP E2A-M12LN08-WP-B1 2M E2A-M12LN08-WP-B2 2M
NPN E2A-M12LN08-WP-C1 2M E2A-M12LN08-WP-C2 2M
M12 connector Brass34 (48)
PNP E2A-M12KN08-M1-B1 E2A-M12KN08-M1-B2NPN E2A-M12KN08-M1-C1 E2A-M12KN08-M1-C2
56 (70)PNP E2A-M12LN08-M1-B1 E2A-M12LN08-M1-B2
NPN E2A-M12LN08-M1-C1 E2A-M12LN08-M1-C2
M18
Shielded 8.0 mm
Pre-wired Brass
39 (59)PNP E2A-M18KS08-WP-B1 2M E2A-M18KS08-WP-B2 2M
NPN E2A-M18KS08-WP-C1 2M E2A-M18KS08-WP-C2 2M
61 (81)PNP E2A-M18LS08-WP-B1 2M E2A-M18LS08-WP-B2 2MNPN E2A-M18LS08-WP-C1 2M E2A-M18LS08-WP-C2 2M
M12 connector Brass
39 (53)PNP E2A-M18KS08-M1-B1 E2A-M18KS08-M1-B2
NPN E2A-M18KS08-M1-C1 E2A-M18KS08-M1-C2
61 (75)PNP E2A-M18LS08-M1-B1 E2A-M18LS08-M1-B2
NPN E2A-M18LS08-M1-C1 E2A-M18LS08-M1-C2
Non-shielded 16.0 mm
Pre-wired Brass39 (59)
PNP E2A-M18KN16-WP-B1 2M E2A-M18KN16-WP-B2 2MNPN E2A-M18KN16-WP-C1 2M E2A-M18KN16-WP-C2 2M
61 (81)PNP E2A-M18LN16-WP-B1 2M E2A-M18LN16-WP-B2 2M
NPN E2A-M18LN16-WP-C1 2M E2A-M18LN16-WP-C2 2M
M12 connector Brass
39 (53)PNP E2A-M18KN16-M1-B1 E2A-M18KN16-M1-B2
NPN E2A-M18KN16-M1-C1 E2A-M18KN16-M1-C2
61 (75)PNP E2A-M18LN16-M1-B1 E2A-M18LN16-M1-B2
NPN E2A-M18LN16-M1-C1 E2A-M18LN16-M1-C2
Size Sensing distance Connection Body
materialThread length (overall length)
Output configuration Operation mode NO Operation mode NC
E-8 Proximity Sensors
Note: M30 non-shielded Models with double sensing distance and short barrelscannot be mounted due to the necessary separation distance from thesurrounding metal. Standard sensing models are thus available.
M30
Shielded 15.0 mm
Pre-wired Brass
44 (64)PNP E2A-M30KS15-WP-B1 2M E2A-M30KS15-WP-B2 2M
NPN E2A-M30KS15-WP-C1 2M E2A-M30KS15-WP-C2 2M
66 (86)PNP E2A-M30LS15-WP-B1 2M E2A-M30LS15-WP-B2 2M
NPN E2A-M30LS15-WP-C1 2M E2A-M30LS15-WP-C2 2M
M12 connector Brass
44 (58)PNP E2A-M30KS15-M1-B1 E2A-M30KS15-M1-B2NPN E2A-M30KS15-M1-C1 E2A-M30KS15-M1-C2
66 (80)PNP E2A-M30LS15-M1-B1 E2A-M30LS15-M1-B2
NPN E2A-M30LS15-M1-C1 E2A-M30LS15-M1-C2
Non-shielded
20.0 mm
Pre-wired Brass
44 (64) (See note.)
PNP E2A-M30KN20-WP-B1 2M E2A-M30KN20-WP-B2 2M
NPN E2A-M30KN20-WP-C1 2M E2A-M30KN20-WP-C2 2M
30.0 mm 66 (86)PNP E2A-M30LN30-WP-B1 2M E2A-M30LN30-WP-B2 2MNPN E2A-M30LN30-WP-C1 2M E2A-M30LN30-WP-C2 2M
20.0 mm
M12 connector Brass
44 (58) (See note.)
PNP E2A-M30KN20-M1-B1 E2A-M30KN20-M1-B2
NPN E2A-M30KN20-M1-C1 E2A-M30KN20-M1-C2
30.0 mm 66 (80)PNP E2A-M30LN30-M1-B1 E2A-M30LN30-M1-B2
NPN E2A-M30LN30-M1-C1 E2A-M30LN30-M1-C2
Size Sensing distance Connection Body
materialThread length
(overall length)Output
configuration Operation mode NO Operation mode NC
E-9E2A
E2A
Model Number Legend
Example: E2A-M12LS04-M1-B1 Standard, M12, long barrel, shielded, Sn=4 mm, M12 connector, PNP-NOE2A-M08KN04-WP-B1 5M Standard, M8, short barrel, non-shielded, Sn=4 mm, pre-wired PVC cable, PNP-NO, cable length=5 m
1. Basic name
E2A
2. Sensing technology
Blank: Standard double distance
3. Housing shape and material
M: Cylindrical, metric threaded, brass
S: Cylindrical, metric threaded, stainless steel
4. Housing size
08: 8 mm
12: 12 mm
18: 18 mm
30: 30 mm
5. Barrel length
K: Standard length
L: Long body
6. Shield
S: Shielded
N: Non-shielded
7. Sensing distance
Numeral: Sensing distance: e.g. 02=2 mm, 16=16 mm
8. Kind of connection
WP: Pre-wired, PVC
M1: M12 connector (4-pole)
M3: M8 connector (4-pole)
M5: M8 connector (3-pole)
9. Power source and output
B: DC, 3-wire, PNP open collector
C: DC, 3-wire, NPN open collector
D: DC, 2-wire
E: DC, 3-wire, NPN voltage output
F: DC, 3-wire, PNP voltage output
10.Operation mode
1: Normally open (NO)
2: Normally closed (NC)
11.Specials (e.g., cable material, oscillating frequency)
12.Cable length
Blank: Connector type
Numeral: Cable type
2 3 4 5 6 7 8 9 10 111 12E2A@-@@@@@-@-@@-@@
E-10 Proximity Sensors
Specifications
DC 3-wire Models
Note 1. The response frequency is an average value. Measurement conditions are as follows: standard target, a distance of twice the standard target distance between targets, and a setting distance of half the sensing distance.
2. When using any model at an ambient temperature between −40°C and −25°C and a power voltage between 30 and 32 VDC, use a load current of 100 mA max.,
3. UL (CSA) [E196555]: Use class 2 circuit only.
Size M8 M12Type Shielded Non-shielded Shielded Non-shielded
Item
E2A-M08@S02-M1-B1E2A-M08@S02-M1-B2E2A-M08@S02-M1-C1E2A-M08@S02-M1-C2E2A-S08@S02-@@-B1E2A-S08@S02-@@-B2E2A-S08@S02-@@-C1E2A-S08@S02-@@-C2
E2A-M08@N04-M1-B1E2A-M08@N04-M1-B2E2A-M08@N04-M1-C1E2A-M08@N04-M1-C2E2A-S08@N04-@@-B1E2A-S08@N04-@@-B2E2A-S08@N04-@@-C1E2A-S08@N04-@@-C2
E2A-M12@S04-@@-B1E2A-M12@S04-@@-B2E2A-M12@S04-@@-C1E2A-M12@S04-@@-C2
E2A-M12@N08-@@-B1E2A-M12@N08-@@-B2E2A-M12@N08-@@-C1E2A-M12@N08-@@-C2
Sensing distance 2 mm ± 10% 4 mm ± 10% 4 mm ± 10% 8 mm ± 10%
Setting distance 0 to 1.6 mm 0 to 3.2 mm 0 to 3.2 mm 0 to 6.4 mm
Differential travel 10% max. of sensing distance
Target Ferrous metal (The sensing distance decreases with non-ferrous metal.)
Standard target (mild steel ST37) 8×8×1 mm 12×12×1 mm 12×12×1 mm 24×24×1 mmResponse frequency (See note 1.) 1,500 Hz 1,000 Hz 1,000 Hz 800 Hz
Power supply voltage (operating voltage range)
12 to 24 VDC. Ripple (p-p): 10% max.(10 to 32 VDC)
Current consumption (DC 3-wire) 10 mA max.
Output type -B models: PNP open collector-C models: NPN open collector
Control output
Load current (See note 2.) 200 mA max. (32 VDC max.)
Residual voltage 2 V max. (under load current of 200 mA with cable length of 2 m)Indicator Operation indicator (Yellow LED)
Operation mode (with sensing object approaching)
-B1/-C1 models: NO -B2/-C2 models: NCFor details, refer to the timing charts.
Protection circuit Power source circuit reverse polarity protection, Surge suppressor, Short-circuit protection
Output reverse polarity protection, Power source circuit reverse polarity protection, Surge suppres-sor, Short-circuit protection
Ambient air temperature Operating: −40°C to 70°C, Storage: −40°C to 85°C (with no icing or condensation)
Temperature influence (See note 2.) ±10% max. of sensing distance at 23°C within temperature range of −25°C to 70°C±15% max. of sensing distance at 23°C within temperature range of −40°C to 70°C
Ambient humidity Operating: 35% to 95%, Storage: 35% to 95%
Voltage influence ±1% max. of sensing distance in rated voltage range ±15%
Insulation resistance 50 MΩ min. (at 500 VDC) between current carry parts and case
Dielectric strength 1,000 VAC at 50/60 Hz for 1 min between current carry parts and caseVibration resistance 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance 500 m/s2, 10 times each in X, Y and Z directions 1,000 m/s2, 10 times each in X, Y and Z directions
Standard and listingsIEC60529: IP67, Degree of protection EN60947-5-2: EMCUL (CSA) [E196555] (See note 3.)
Connection method-WP models: Pre-wired models (Standard length: 2 m)-M1 models: M12 4-pin connector models-M5 models: M8 3-pin connector models
Weight (packaged)
Pre-wired model Approx. 65 g Approx. 85 g
M12 connector model M12 connector models: Approx. 20 gM8 connector models: Approx. 15 g Approx. 35 g
Material
Case Stainless steel or brass-nickel plated Brass-nickel plated
Sensing surface PBT
Cable PVC
Clamping nut Brass-nickel plated
E-11E2A
E2A
DC 3-wire Models
Note 1. The response frequency is an average value. Measurement conditions are as follows: standard target, a distance of twice the standard target distance between targets, and a setting distance of half the sensing distance.
2. When using any model at an ambient temperature between -40°C and -25°C and a power voltage between 30 and 32 VDC, use a load current of 100 mA max.
3. UL (CSA) [E196555]: Use class 2 circuit only.
Size M18 M30Type Shielded Non-shielded Shielded Non-shielded Non-shielded
Item
E2A-M18@S08-@@-B1E2A-M18@S08-@@-B2E2A-M18@S08-@@-C1E2A-M18@S08-@@-C2
E2A-M18@N16-@@-B1E2A-M18@N16-@@-B2E2A-M18@N16-@@-C1E2A-M18@N16-@@-C2
E2A-M30@S15-@@-B1E2A-M30@S15-@@-B2E2A-M30@S15-@@-C1E2A-M30@S15-@@-C2
E2A-M30KN20-@@-B1E2A-M30KN20-@@-B2E2A-M30KN20-@@-C1E2A-M30KN20-@@-C2
E2A-M30LN30-@@-B1E2A-M30LN30-@@-B2E2A-M30LN30-@@-C1E2A-M30LN30-@@-C2
Sensing distance 8 mm±10% 16 mm±10% 15 mm±10% 20 mm±10% 30 mm±10%
Setting distance 0 to 6.4 mm 0 to 12.8 mm 0 to 12 mm 0 to 16 mm 0 to 24 mm
Differential travel 10% max. of sensing distance
Target Ferrous metal (The sensing distance decreases with non-ferrous metal.)Standard target (mild steel ST37) 24×24×1 mm 48×48×1 mm 45×45×1 mm 60×60×1 mm 90×90×1 mm
Response frequency (See note 1.) 500 Hz 400 Hz 250 Hz 100 Hz 100 Hz
Power supply voltage (operating voltage range)
12 to 24 VDC. Ripple (p-p): 10% max.(10 to 32 VDC)
Current consumption (DC 3-wire) 10 mA max.
Output type -B models: PNP open collector-C models: NPN open collector
Control output
Load current (See note 2.) 200 mA max. (32 VDC max.)
Residual voltage 2 V max. (under load current of 200 mA with cable length of 2 m)
Indicator Operation indicator (Yellow LED)
Operation mode (with sensing object approa-ching)
-B1/-C1 models: NO -B2/-C2 models: NCFor details, refer to the timing charts.
Protection circuit Output reverse polarity protection, Power source circuit reverse polarity protection, Surge suppressor, Short-circuit protection
Ambient air temperature Operating: −40°C to 70°C, Storage: −40°C to 85°C (with no icing or condensation)
Temperature influence (See note 2.)
±10% max. of sensing distance at 23°C within temperature range of −25°C to 70°C±15% max. of sensing distance at 23°C within temperature range of −40°C to 70°C
Ambient humidity Operating: 35% to 95%, Storage: 35% to 95%
Voltage influence ±1% max. of sensing distance in rated voltage range ±15%
Insulation resistance 50 MΩ min. (at 500 VDC) between current carry parts and case
Dielectric strength 1,000 VAC at 50/60 Hz for 1 min between current carry parts and caseVibration resistance 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance 1,000 m/s2, 10 times each in X, Y and Z directions
Standard and listingsIEC60529: IP67, Degree of protection EN60947-5-2: EMCUL (CSA) [E196555] (See note 3.)
Connection method-WP models: Pre-wired models (Standard length: 2 m)-M1 models: M12 4-pin connector models-M5 models: M8 3-pin connector models
Weight (pak-kaged)
Pre-wired model Approx. 160 g Approx. 280 g Approx. 280 g Approx. 370 g
M12 connector model Approx. 70 g Approx. 200 g Approx. 200 g Approx. 260 g
Material
Case Brass-nickel plated
Sensing surface PBT
Cable PVC
Clamping nut Brass-nickel plated
E-12 Proximity Sensors
Engineering Data
Operating Range (Typical)
Influence of Sensing Object Size and MaterialsShielded Models
Distance Y (mm)
X
Y
18
16
14
12
10
8
6
4
2
0−30 −20 −10 0 10 20 30
E2A-M30@S15
Sen
sing
dis
tanc
e X
(m
m)
E2A-M18@S08
E2A-M12@S04E2A-S08@S02/ E2A-M08@S02
Shielded Models
X
Y
35
30
25
20
15
10
5
0−50 −40 −30 −20 −10 0 10 20 30 40 50
Non-shielded Models
Distance Y (mm)
Sen
sing
dis
tanc
e X
(m
m)
E2A-M30LN30
E2A-M18@N16
E2A-M12@N08
E2A-S08@N04/ E2A-M08@N04
E2A-M30KN20
0 5 10 15 20 25
Side length of sensing object d (mm)
Iron
@dt = 1 mm
X
0.5
1.0
1.5
2.0
2.5 5.0
4.0
3.0
2.0
1.0
0
@dt = 1 mm
X
5 10 15 20 25 30 35 0
1.0
2.0
3.0
4.0
5.0
7.0
8.0
6.0
10 20 30 40 50 60
@dt = 1 mm
X
0
4
8
12
16
20
10 20 30 40 50 60 70 80
@dt = 1 mm
X
Sen
sing
dis
tanc
e X
(m
m)
Stainless steel (SUS303)
Aluminum
Side length of sensing object d (mm)
Brass
Iron
Sen
sing
dis
tanc
e X
(m
m)
Stainless steel (SUS303)
Aluminum
Copper
Side length of sensing object d (mm)
Brass
Iron
Sen
sing
dis
tanc
e X
(m
m)
Copper
Stainless steel (SUS303)
Aluminum
E2A-S08@S02/M08@S02 E2A-M12@S04 E2A-M18@S08
E2A-M30@S15
Side length of sensing object d (mm)
Sen
sing
dis
tanc
e X
(m
m)
Iron
Stainless steel (SUS303)
Brass
Copper
Brass
Copper
Aluminum
E-13E2A
E2A
Non-shielded Models
5.0
4.0
3.0
2.0
1.0
0 10 20 30 40 50
@dt = 1 mm
X
10
8
6
4
2
0
@dt = 1 mm
X
10 20 30 40 50
20
16
12
8
4
0
@dt = 1 mm
X
20 40 60 80
0
5
10
15
20
25
35
30
20 40 60 80 100
@dt = 1 mm
X
E2A-S08@N04/M08@N04
Side length of sensing object d (mm)
Sen
sing
dis
tanc
e X
(m
m)
Iron
Brass
Copper
Stainless steel (SUS303)
E2A-M12@N08
Side length of sensing object d (mm)
Sen
sing
dis
tanc
e X
(m
m)
Iron
Brass
Aluminum
Stainless steel (SUS303)
Copper
E2A-M18@N16
Side length of sensing object d (mm)
Sen
sing
dis
tanc
e X
(m
m)
Iron
Copper
Brass
Aluminum
E2A-M30LN30
Side length of sensing object d (mm)
Sen
sing
dis
tanc
e X
(m
m)
Iron
Copper
Brass
Aluminum
Stainless steel (SUS303)
Stainless steel (SUS303)
Aluminum
Side length of sensing object d (mm)
Sen
sing
dis
tanc
e X
(m
m) 25
20
15
10
5
0 20 40 60 80 100
t = 1 mm@d
X
Copper
Brass
Iron
Aluminum
Stainless steel (SUS303)
E2A-M30KN20
E-14 Proximity Sensors
Operation
PNP OutputOperation mode Model Timing chart Output circuit
NO E2A-@-@-B1
NC E2A-@-@-B2
Sensingobject
(%) 100 0
Rated
sensingdistance
Sensing zoneNon-sensing zoneProximity Sensor
ON
OFF
ON
OFF
Yellow indicator
Control output
3
1
2 4 31
4
Load
Brown
Black
(See note 1.)
Blue
+V
0 V
Note 1: With M8 connector models, there is no output reverse polarity protection diode.
M12 Connector Pin Arrangement
(See note 2.)
M8 Connector Pin Arrangement
Note 2: Terminal 2 of the M12 connector is not used.
Proximity Sensor main circuits
(%) 100 0
Sensingobject
Rated
sensingdistance
Sensing zoneNon-sensing zoneProximity Sensor
ON
OFF
ON
OFF
Yellow indicator
Control output
3
1
2 4 31
4
Load
Brown
Black
(See note 1.)
Blue
+V
0 V
Note 1: With M8 connector models, there is no output reverse polarity protection diode.
M12 Connector Pin Arrangement
(See note 2.)
M8 Connector Pin Arrangement
Note 2: Terminal 4 of the M12 connector is not used.
Proximity Sensor main circuits
(M8 connector: )
E-15E2A
E2A
NPN OutputOperation mode Model Timing chart Output circuit
NO E2A-@-@-C1
NC E2A-@-@-C2
Sensingobject
(%) 100 0
Rated
sensingdistance
Sensing zoneNon-sensing zoneProximity Sensor
ON
OFF
ON
OFF
Yellow indicator
Control output
Load
Brown
Black(See note 1.)
Blue
+V
0 V
Note 1: With M8 connector models, there is no output reverse polarity protection diode.
M12 Connector Pin Arrangement
(See note 2.)
3
1
2 4
M8 Connector Pin Arrangement
31
4
Note 2: Terminal 2 of the M12 connector is not used.
Proximity Sensor main circuits
(%) 100 0
Sensingobject
Rated
sensingdistance
Sensing zoneNon-sensing zoneProximity Sensor
ON
OFF
ON
OFF
Yellow indicator
Control output
3
1
2 4 31
4
Load
Brown
Black(See note 1.)
Blue
+V
0 V
Note 1: With M8 connector models, there is no output reverse polarity protection diode.
M12 Connector Pin Arrangement
(See note 2.)
M8 Connector Pin Arrangement
Note 2: Terminal 4 of the M12 connector is not used.
Proximity Sensor main circuits (M8 connector: )
E-16 Proximity Sensors
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Pre-wired Models (Shielded) Pre-wired Models (Non-shielded)
3 5
27
40
13
M8×1
(See note 1.)
E2A-S08KS02-WP-@@
3
40
5
27
13 6
M8×1
5.8 dia.
E2A-S08KN04-WP-@@
4
50.3
7
3417
M12×1Two, clamping nuts
E2A-M12KS04-WP-@@ E2A-M12KN08-WP-@@
4 7
34
50.3
17 7
9.2 dia.
M12×1
M18×1
4 10
39
59.5
24
E2A-M18KS08-WP-@@ E2A-M18KN16-WP-@@
1039
59.5
24 10 4
15.1 dia.
M18×1
E2A-M30KS15-WP-@@
5 10
64.5
44
36
M30×1.5
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
Indicator (See note 2.)(See note 1.)
(See note 1.)
(See note 1.)
(See note 1.)
(See note 1.)
(See note 1.)
Two, clamping nutsIndicator (See note 2.)
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
Two, clamping nuts
Indicator (See note 2.)
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
Two, clamping nuts
Indicator (See note 2.)
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
Two, clamping nuts
Indicator (See note 2.)
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
Two, clamping nuts
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
Indicator (See note 2.)
Two, clamping nuts
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
Indicator (See note 2.)M30×1.5
(See note 1.)
Two, clamping nuts
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
Indicator (See note 2.)
26.4 dia.
36 5
4415 10
64.5
E2A-M30KN20-WP-@@
E-17E2A
E2A
M12×1
17
72.3
56
74
M12×1
17
72.3
56
747
9.2 dia.
M18×1
24
81.561
104
10
61 81.5
24 10 4
15.1 dia.
M18×1
5 10
86.566
36
M30×1.5
M30×1.5
26.4 dia.
105
6686.5
1536
(See note 1.) (See note 1.)
(See note 1.)
(See note 1.)
(See note 1.)
(See note 1.)
E2A-M12LS04-WP-@@
E2A-M18LS08-WP-@@
E2A-M12LN08-WP-@@
E2A-M18LN16-WP-@@
E2A-M30LN30-WP-@@E2A-M30LS15-WP-@@
Two, clamping nuts
Indicator (See note 2.)
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow) Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m2. Operation indicator (yellow)
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
Two, clamping nuts
Indicator (See note 2.)
Two, clamping nuts
Indicator (See note 2.)
Two, clamping nuts
Indicator (See note 2.)
Two, clamping nuts
Indicator (See note 2.)
Two, clamping nuts
Indicator (See note 2.)
Mounting Hole Cutout Dimensions
F
External diameter of Proximity Sensor Dimension F (mm)
M18
M30
M8
M12
8.5 dia.+0.50
12.5 dia.+0.50
18.5 dia.+0.50
30.5 dia.+0.50
3 549
62
13
M8×1
(See note 1.)
E2A-S08LS02-WP-@@
3
62
5
49
13 6
M8×1
5.8 dia.
E2A-S08LN04-WP-@@
(See note 1.)
Two, clamping nutsIndicator (See note 2.)
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
Two, clamping nuts
Indicator (See note 2.)
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
E-18 Proximity Sensors
M12 Connector Models (Shielded) M12 Connector Models (Non-shielded)
E2A-S08KS02-M1-@@E2A-M08KS02-M1-@@
E2A-M12KS04-M1-@@ E2A-M12KN08-M1-@@
27
43
3 513
M8×1
M12×1
Note: Operation indicator (yellow LED, 4×90°)
E2A-S08KN04-M1-@@E2A-M08KN04-M1-@@
6 dia.
3 527
43
613
M8×1
M12×1
E2A-M18KS08-M1-@@ E2A-M18KN16-M1-@@
74
34
48
17
M12×1
M12×1
9.4 dia.
4
34
48
7 7
17
M12×1
M12×1
1024 4
39
53
M18×1
M12×124 104
39
53
10
15.3 dia.
M18×1
M12×1
E2A-M30KS15-M1-@@
44
5
58
36 10
M30×1.5
M12×1
Note: Operation indicator (yellow LED, 4×90°)
Note: Operation indicator (yellow LED, 4×90°)
Note: Operation indicator (yellow LED, 4×90°)
Note: Operation indicator (yellow LED, 4×90°)
Note: Operation indicator (yellow LED, 4×90°)
Note: Operation indicator (yellow LED, 4×90°)
Two, clamping nutsIndicator (See note.)
Two, clamping nuts
Indicator (See note.)
Two, clamping nuts
Indicator (See note.)
Two, clamping nuts
Indicator (See note.)
Two, clamping nuts
Indicator (See note.)
Two, clamping nuts
Indicator (See note.)
Two, clamping nuts
Indicator (See note.)
26.6 dia.
M12×1
Note: Operation indicator (yellow LED, 4×90°)
51536
44
10
58
M30×1.5
Indicator (See note.)
Two, clamping nuts
E2A-M30KN20-M1-@@
E-19E2A
E2A
M8 Connector Models (Shielded) M8 Connector Models (Non-shielded)
74
56
70
17
M12×1
M12×1
9.2 dia.
4
56
70
7717
M12×1
M12×1
1024 4
61
75
M18×1
M12×1
24 104
6175
10
15.1 dia.
M18×1
M12×1
665
80
36 10
M30×1.5
M12×1
1051566
80
36
26.6 dia.
M30×1.5
Note: Operation indicator (yellow LED, 4×90°)
Note: Operation indicator (yellow LED, 4×90°)
Note: Operation indicator (yellow LED, 4×90°)
Note: Operation indicator (yellow LED, 4×90°)
Note: Operation indicator (yellow LED, 4×90°)
Note: Operation indicator (yellow LED, 4×90°)
E2A-M12LS04-M1-@@
E2A-M18LS08-M1-@@
E2A-M30LS15-M1-@@
E2A-M12LN04-M1-@@
E2A-M18LN16-M1-@@
E2A-M30LN30-M1-@@
Two, clamping nutsIndicator (See note.)
Two, clamping nuts
Indicator (See note.)
Two, clamping nuts
Indicator (See note.)
Two, clamping nuts
Indicator (See note.)
Two, clamping nuts
Indicator (See note.)
Two, clamping nutsIndicator (See note.)
E2A-S08LS02-M1-@@E2A-M08LS02-M1-@@
49
65
3 513
M8×1
M12×1
Note: Operation indicator (yellow LED, 4×90°)
E2A-S08LN04-M1-@@E2A-M08LN04-M1-@@
6 dia.
3 549
65
613
M8×1
M12×1
Note: Operation indicator (yellow LED, 4×90°)
Two, clamping nutsIndicator (See note.) Indicator (See note.)
M8×1
M8×1
E2A-S08KS02-M5-@@ E2A-S08KN04-M5-@@
5.8 dia.
3613 5
27
39
M8×1
M8×1
Note: Operation indicator (yellow LED, 4×90°) Note: Operation indicator (yellow LED, 4×90°)
313
27
5
39
Two, clamping nuts Two, clamping nuts
M8×1
M8×1
E2A-S08LS02-M5-@@ E2A-S08LN04-M5-@@
5.8 dia.
3613 5
49
61
M8×1
M8×1
Note: Operation indicator (yellow LED, 4×90°) Note: Operation indicator (yellow LED, 4×90°)
313
49
5
61
E-20 Proximity Sensors
Precautions
Safety PrecautionsPower SupplyDo not impose an excessive voltage on the E2A, otherwise it may bedamaged. Do not impose AC current (100 to 240 VAC) on any DCmodel, otherwise it may be damaged.
Load Short-circuitDo not short-circuit the load, or the E2A may be damaged.
The E2A’s short-circuit protection function will be valid if the polarityof the supply voltage imposed is correct and within the rated voltagerange.
WiringBe sure to wire the E2A and load correctly, otherwise it may be dam-aged.
Connection with No LoadBe sure to insert loads when wiring. Make sure to connect a properload to the E2A in operation, otherwise it may damage internal ele-ments.
Do not expose the product to flammable or explo-sive gases.
Do not disassemble, repair, or modify the product.
Correct UseDesigningPower Reset Time
The Proximity Sensor is ready to operate within 100 ms after poweris supplied. If power supplies are connected to the Proximity Sensorand load respectively, be sure to supply power to the Proximity Sen-sor before supplying power to the load.
Effects of Surrounding Metal
When mounting the E2A within a metal panel, ensure that the clear-ances given in the following table are maintained.
(Unit: mm)
Note 1. In the case of using the supplied nuts. If true flash mounting is necessary, apply a free zone of 1.5 mm.
2. In the case of using the supplied nuts. If true flush mounting is necessary, apply a free zone of 4 mm.
Power OFF
The Proximity Sensor may output a pulse signal when it is turnedOFF. Therefore, it is recommended that the load be turned OFFbefore turning OFF the Proximity Sensor.
Power Supply Transformer
When using a DC power supply, make sure that the DC power sup-ply has an insulated transformer. Do not use a DC power supply withan auto-transformer.
Mutual Interference
When installing two or more Sensors face-to-face or side-by-side,ensure that the minimum distances given in the following table aremaintained.
(Unit: mm)
Type Dimension M8 M12 M18M30
Short barrel
Long barrel
Shielded
l 0 00 (See note 1.)
0 (See note 2.)
m 4.5 12 24 45
d --- --- 27 45
D 0 0 1.5 4
n 12 18 27 45
Non-shielded
l 12 15 22 30 40
m 8 20 48 70 90d 24 40 70 90 120
D 12 15 22 30 40
n 24 40 70 90 120
l
mn
mD
d dia.
l
Type Dimension M8 M12 M18M30
Short barrel
Long barrel
ShieldedA 20 30 60 110
B 15 20 35 70
Non-shielded
A 80 120 200 300 300
B 60 100 120 200 300
E-21E2A
E2A
WiringHigh-tension Lines
Wiring through Metal Conduit:If there is a power or high-tension line near the cable of the ProximitySensor, wire the cable through an independent metal conduit to pre-vent against Proximity Sensor damage or malfunctioning.
Cable Extension
Standard cable length is less than 200 m.
The tractive force is 50 N.
MountingThe Proximity Sensor must not be subjected to excessive shock witha hammer when it is installed, otherwise the Proximity Sensor maybe damaged or lose its water-resistivity.
Do not tighten the nut with excessive force. A washer must be usedwith the nut.
Maintenance and InspectionPeriodically perform the following checks to ensure stable operationof the Proximity Sensor over a long period of time.
1. Check for mounting position, dislocation, looseness, or distortionof the Proximity Sensor and sensing objects.
2. Check for loose wiring and connections, improper contacts, andline breakage.
3. Check for attachment or accumulation of metal powder or dust.4. Check for abnormal temperature conditions and other environ-
mental conditions.5. Check for proper lighting of indicators (for models with a set indi-
cator.)
Never disassemble or repair the Sensor.
EnvironmentWater Resistivity
The Proximity Sensors are tested intensively on water resistance,but in order to ensure maximum performance and life expectancyavoid immersion in water and provide protection from rain or snow.
Operating Environment
Ensure storage and operation of the Proximity Sensor within thegiven specifications.
Inrush Current
A load that has a large inrush current (e.g., a lamp or motor) willdamage the Proximity Sensor, in which case connect the load to theProximity Sensor through a relay.
<SUITABILITY FOR USE>OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of the products in the customer’s application or use of the products.
Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will be used.
<CHANGE IN SPECIFICATIONS>Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with your OMRON representative at any time to confirm actual specifications of purchased product.
Type TorqueM8 Stainless steel
type9 Nm
Brass type 4 Nm
M12 30 NmM18 70 Nm
M30 180 Nm
Type Torque
E-22 Proximity Sensors
Cylindrical Proximity Sensor
E2EWell established Series of Easy-to-use and Tough E2E Models
Ordering Information
SensorsDC 2-wire/Pre-wired Models (3-wire with a self-diagnostic function.)
Self diagnostic output function
Shape Sensing distanceModel
NO NC
ON or OFF delay 0 to 5 s (adjustable)
M12 E2E-X3D1S *1 ---
M18 E2E-X7D1S *1 ---
M30 E2E-X10D1S *1 ---
M12 E2E-X8MD1S *1 ---
M18 E2E-X14MD1S *1 ---
M30 E2E-X20MD1S *1 ---
No
M8 E2E-X2D1-N *2*3 E2E-X2D2-N *3
M12 E2E-X3D1-N *1*2*3 E2E-X3D2-N *3
M18 E2E-X7D1-N *1*2*3 E2E-X7D2-N *3
M30 E2E-X10D1-N *1*2*3 E2E-X10D2-N
M8 E2E-X4MD1 *2*3 E2E-X4MD2
M12 E2E-X8MD1 *1*2*3 E2E-X8MD2
M18 E2E-X14MD1 *1*2*3 E2E-X14MD2
M30 E2E-X20MD1 *1*2*3 E2E-X20MD2
*1. A different frequency type is prepared. (E2E-X #D15; e.g.E2E-X3D15-N)*2. E2E models with a robotic cable are available as well. The model number of a model with a robotic cable has the suffix "-R" (e.g., E2E-X3D1-R).*3. Beside standard cable length 2 m the 5 m long cable is the prefered length. Please designate a cable length to the bottom of model number. (e.g. E2E-X2D1-N 5M)
Shielded 3 mm
7 mm
10 mm
Unshielded 8 mm
14 mm
20 mm
Shielded2 mm
3 mm
7 mm
10 mm
Unshielded4 mm
8 mm
14 mm
20 mm
E-23E2E
E2E
DC 2-wire/Connector Models (3-wire with a self-diagnostic function.)
DC 2-wired/Connector Extension Models
Note: 1 .Since non-polarity type residual voltage is 5V, check interface conditions with connection load (e.g. ON voltage of PLC etc.).2 .Standard cable length is 300 mm. Besides a cable length of 500 mm and 1 m type can be created.
DC 3-wire/Pre-wired Models
Beside standard cable length 2 m, the 5 m cable is the prefered length. Please allocate a cable length to the bottom of model number. (e.g. E2EG-X2C1-5M)
Con-nector
Self diagnostic
output function
Shape Sensing distance
Model
NO
Appli-cable con-
nector
NC
Appli-cable con-
nector
M12
ON or OFF delay 0 to 5 s (adjustable)
M12 E2E-X3D1S-M1 D --- ---
M18 E2E-X7D1S-M1 D --- ---
M30 E2E-X10D1S-M1 D --- ---
M12 E2E-X8MD1S-M1 D --- ---
M18 E2E-X14MD1S-M1 D --- ---
M30 E2E-X20MD1S-M1 D --- ---
No
M8 E2E-X2D1-M1G A E2E-X2D2-M1G D
M12 E2E-X3D1-M1G *1
*1. A different frequency type is prepared. (E2E-X #D15-M1G; e.g.E2E-X3D15-M1G
A E2E-X3D2-M1G D
M18 E2E-X7D1-M1G *1 A E2E-X7D2-M1G D
M30 E2E-X10D1-M1G *1 A E2E-X10D2-M1G D
M8 E2E-X4MD1-M1G A E2E-X4MD2-M1G D
M12 E2E-X8MD1-M1G *1 A E2E-X8MD2-M1G D
M18 E2E-X14MD1-M1G *1 A E2E-X14MD2-M1G D
M30 E2E-X20MD1-M1G *1 A E2E-X20MD2-M1G D
M8 M8
E2E-X2D1-M3G G E2E-X2D2-M3G G
E2E-X4MD1-M3G G E2E-X4MD2-M3G G
Shape Sensing distanceOperating
status
Model
Yes polarityApplicable connector
No polarityApplicable connector
M12
NO
E2E-X3D1-M1GJ A E2E-X3D1-M1J-T B
M18 E2E-X7D1-M1GJ A E2E-X7D1-M1J-T B
M30 E2E-X10D1-M1GJ A E2E-X10D1-M1J-T B
M12 E2E-X8MD1-M1GJ A --- ---
M18 E2E-X14MD1-M1GJ A --- ---
M30 E2E-X20MD1-M1GJ A --- ---
Shape Sensing distanceModel
PNP - NO PNP - NC NPN - NO NPN - NC
4 mm dia. E2E-CR8B1 E2E-CR8B2 E2E-CR8C1 E2E-CR8C2
M5 E2E-X1B1 E2E-X1B2 E2E-X1C1 E2E-X1C2
5.4 mm dia. E2E-C1B1 E2E-C1B2 E2E-C1C1 E2E-C1C2
Shielded 3 mm
7 mm
10 mm
Unshielded 8 mm
14 mm
20 mm
Shielded2 mm
3 mm
7 mm
10 mm
Unshielded4 mm
8 mm
14 mm
20 mm
Shielded2 mm
Unshielded
4 mm
Shielded 3 mm
7 mm
10 mm
Unshielded 8 mm
14 mm
20 mm
Shielded 0.8 mm
1 mm
1 mm
E-24 Proximity Sensors
AC 2-wire/Pre-wired Models
AC 2-wire/Connector Models
* Refer to E-33 page for details.
Shape Sensing distanceModel
NO NC
M8 E2E-X1R5Y1 E2E-X1R5Y2
M12 E2E-X2Y1 *1
*1. A different frequency type is prepared. (E2E-X #Y#5; e.g.E2E-X5Y15)
E2E-X2Y2 *1
M18 E2E-X5Y1 *1 E2E-X5Y2 *1
M30 E2E-X10Y1 *1 E2E-X10Y2 *1
M8 E2E-X2MY1 E2E-X2MY2
M12 E2E-X5MY1 *1 E2E-X5MY2 *1
M18 E2E-X10MY1 *1 E2E-X10MY2 *1
M30 E2E-X18MY1 *1 E2E-X18MY2 *1
Connector Shape Sensing distanceModel
operating configura-tion, NO
Applicable connector*
operating configura-tion, NC
Applicable connector*
M12
M12 E2E-X2Y1-M1 E E2E-X2Y2-M1 F
M18 E2E-X5Y1-M1 E E2E-X5Y2-M1 F
M30 E2E-X10Y1-M1 E E2E-X10Y2-M1 F
M12 E2E-X5MY1-M1 E E2E-X5MY2-M1 F
M18 E2E-X10MY1-M1 E E2E-X10MY2-M1 F
M30 E2E-X18MY1-M1 E E2E-X18MY2-M1 F
Shielded1.5 mm
2 mm
5 mm
10 mm
Unshielded2 mm
5 mm
10 mm
18 mm
Shielded 2 mm
5 mm
10 mm
Unshielded 5 mm
10 mm
18 mm
E-25E2E
E2E
Rating/Performance
DC 2-wire Models (E2E-X#D#)
Size M8 M12 M18 M30
Shielded Shielded Unshielded Shielded Unshielded Shielded Unshielded Shielded Unshielded
Item ModelE2E-X2D#
E2E-X4MD#
E2E-X3D#
E2E-X8MD#
E2E-X7D#
E2E-X14MD#
E2E-X10D#
E2E-X20MD#
Sensing distance 2 mm ±10% 4 mm ±10% 3 mm ±10% 8 mm ±10% 7 mm ±10% 14 mm ±10% 10 mm ±10% 20 mm ±10%
Setting distance*1 0 to 1.6 mm 0 to 3.2 mm 0 to 2.4 mm 0 to 6.4 mm 0 to 5.6 mm 0 to 11.2 mm 0 to 8 mm 0 to 16 mm
Differential distance
15% max. of sensing distance
10% max.
Sensing object Ferrous metal (Sensitivity lowers with non-ferrous metals)
Standard sensing object (mild steel)
8 x 8 x 1 mm 20 x 20 x 1 mm 12 x 12 x 1 mm 30 x 30 x 1 mm 18 x 18 x 1 mm 30 x 30 x 1 mm 54 x 54 x 1 mm
Response frequency*2
1.5 kHz 1 kHz 0.8 kHz 0.5 kHz 0.4 kHz 0.1 kHz
Power supply(Operating voltage range)
12 to 24 VDC (10 to 30 VDC) ripple (p-p): 10% max.
Leakage current 0.8 mA max.
Control output
Switch-ing ca-pacity
3 to 100 mA (5 to 100 mA for -M1J-T models), Diagnostic output: 50 mA for D1 (5) S models
Residu-al volt-age*3
3.0 V max. (under load current of 100 mA with cable length of 2 m), 5.0 V min. for -M1J-T models
Indicator lamp D1 type: Operation indicator (red), operation setting indicator (green)D2 type: Operation indicator (red)
Operating status (with sensing ob-ject approaching)
D1 type: NOD2 type: NC
Diagnostic output delay
0.3 to 1s
Protective circuits Surge absorber, load short-circuit protection (for control and diagnostic output)
Ambient temperature
Operating: -25°C to 70°C, Storage: -40°C to 85°C (with no icing or condensation)
Ambient humidity Operating/Storage: 35% to 95%RH (with no condensation)
Temperature influence
±15% max. of sensing dis-tance at 23°C within temper-ature range of -25°C to 70°C
±10% max. sensing distance at 23°C within temperature range of -25°C to 70°C
Voltage influence ±1% max. of sensing distance in rated voltage range ±15%
Insulation resistance
50 M min. (500 VDC) between energized part and case
Dielectric strength 1000 VAC 50/60 Hz for 1 min between energized part and case
Vibration resistance
10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistanceDestruction: 500 m/s2 for 10 times each in X, Y, and Z directions
Destruction: 1,000 m/s2 for 10 times each in X, Y, and Z directions
Protective structure
Pre-wired, Connector Extension models: IEC60529 IP67 Connector type: IP67
Connection method
Pre-wired models (Standard length: 2 m), Connector models, Connector extension models (Standard length: 300 mm)
E-26 Proximity Sensors
Wei
ght (
Pac
ked
stat
e) Pre-wired models
Approx. 45 g Approx. 55 g Approx. 130 g Approx. 180 g
Sensor with Connec-tor Relay
--- Approx.40g Approx. 70 g Approx. 110 g
Connec-tor
Approx. 10 g Approx. 20 g Approx. 40g Approx. 90 g
Mate-rial
Case Stainless steel (SUS303) Brass
Sensing surface
PBT
Accessories Instruction manual
*1. Use within a range where the green indicator is lit. (Excluding the D2 models.)*2. The response frequencies for DC switching are average values measured on condition that the distance between each sensing object is twice as large as the
size of the sensing object and the sensing distance set is half of the maximum sensing distance.*3. Since the residual voltage turns 5V when using an M1J-T type, please use it after checking interface conditions with connection device.
Size M8 M12 M18 M30
Shielded Shielded Unshielded Shielded Unshielded Shielded Unshielded Shielded Unshielded
Item ModelE2E-X2D#
E2E-X4MD#
E2E-X3D#
E2E-X8MD#
E2E-X7D#
E2E-X14MD#
E2E-X10D#
E2E-X20MD#
E-27E2E
E2E
DC 3-wire Models (E2E-C#B#/C#, E2E-X1B#/C#)
* The response frequencies for DC switching are average values measured oncondition that the distance between each sensing object is twice as large asthe size of the sensing object and the sensing distance set is half of the max-imum sensing distance.
Size 4 mm dia. 5.4 mm dia. M5
Shielded Shielded
Item Model E2E-CR8B#/C# E2E-X1B#/C# E2E-C1B#/C#
Sensing distance 0.8 mm ±15% 1 mm ±15%
Setting distance 0 to 0.5 mm 0 to 0.7 mm
Differential distance 15% max. of sensing distance
Sensing object Ferrous metal (Sensitivity lowers with non-ferrous metals)
Standard sensing object Mild steel, 5 x 5 x 1 mm
Response frequency 3 kHz
Power supply(Operating voltage range)
12 to 24 VDC (10 to 30 VDC) ripple (p-p): 10% max.
Current consumption 17 mA max.
Control out-put
Switching capacity
Open collector output 100 mA max. (30 VDC max.)
Residual voltage
2 V max. (under load current of 100 mA with cable length of 2 m)
Indicator lamp Operation indicator (red)
Operating status (with sensing object approaching)
C1/B1 type: NOC2/B2 type: NC
Protective circuits Reverse connection protection, surge absorber
Ambient temperature Operating/Storage: -25°C to 70°C (with no icing or condensation)
Ambient humidity Operating/Storage: 35% to 95%RH
Temperature influence ±15% max. of sensing distance at 23°C within temperature range of -25°C to 70°C
Voltage influence ±2.5% max. of sensing distance within rated voltage range ±25%
Insulation resistance 50 M min. (500 VDC) between energized part and case
Dielectric strength 500 VAC 50/60 Hz for 1 min between energized part and case
Vibration resistance 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 500 m/s2 for 10 times each in X, Y, and Z directions
Protective structure IEC60529 IP67
Connection method Pre-wired models (Standard length: 2 m)
Weight (Packed state) 30 g
Material
Case Stainless steel (SUS303) Brass
Sensing surface
Heat-resistant ABS resin
Accessories Instruction manual
E-28 Proximity Sensors
AC 2-wire Models (E2E-X#Y#)
Size M8 M12 M18 M30
Shielded Shielded Unshielded Shielded Unshielded Shielded Unshielded Shielded Unshielded
Item ModelE2E-X1R5Y#
E2E-X2MY#
E2E-X2Y#
E2E-X5MY#
E2E-X5Y#
E2E-X10MY#
E2E-X10Y#
E2E-X18MY#
Sensing distance 1.5 mm ±10% 2 mm ±10% 5 mm ±10% 10 mm ±10% 18 mm ±10%
Setting distance 0 to 1.2 mm 0 to 1.6 mm 0 to 4 mm 0 to 8 mm 0 to 14 mm
Differential distance 10% max.
Sensing object Ferrous metal (Sensitivity lowers with non-ferrous metals)
Standard sensing object (Mild steel)
8 x 8 x 1 mm 12 x 12 x 1 mm 15 x 15 x 1 mm 18 x 18 x 1 mm 30 x 30 x 1 mm 54 x 54 x 1 mm
Response frequency 25 Hz
Power supply(Operating voltage range)*1
*1. For the 24 VAC supply to any of the aforesaid models, ensure that the operating ambient temperature range exceeds -25°C.
24 to 240 VAC 50/60Hz (20 to 264 VAC)
Leakage current 1.7 mA max.
Con-trol out-put
Switching capacity*2
*2. When using M18-or M30-sized E2E within an ambient temperature range of 70°C to 85°C, ensure that E2E has a control output of 200 mA maximum.
5 to 100 mA 5 to 200 mA 5 to 300 mA
Residual voltage
Refer to Specifications
Indicator lamp Operation indicator (red)
Operating status (with sensing ob-ject approaching)
Y1 type: NOY2 type: NC
Protective circuits Surge absorber
Ambient tempera-ture
Operating: -25°C to 70°C Preservation: -25°C to 70°C (with no icing)
Operating/Storage: -40°C to 85°C (with no icing or condensation)
Ambient humidity Operating/Storage: 35% to 95%RH (with no condensation)
Temperature influ-ence
±10% max. of sensing dis-tance at 23°C within temper-ature range of -25°C to 70°C
±15% max. of sensing distance at 23°C within temperature range -40°C to 85°C±10% max. of sensing distance at 23°C within temperature range -25°C to 70°C
Voltage influence ±1% max. of sensing distance within rated voltage range ±15%
Insulation resistance
50 M min. (500 VDC) between energized part and case
Dielectric strength 4,000 VAC for 1 min between energized parts and case (2,000 VAC for M8 types)
Vibration resistance
10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistanceDestruction: 500 m/s2 for 10 times each in X, Y, and Z directions
Destruction: 1,000 m/s2 for 10 times each in X, Y, and Z directions
Protective structure IEC60529 IP67
Connection method Pre-wired models (Standard length: 2 m), Connector models
Weight
Pre-wired models
Approx. 45 g Approx. 55 g Approx. 130 g Approx. 180 g
Connector Approx. 10 g Approx. 20 g Approx. 40g Approx. 90 g
Materi-al
Case Stainless steel (SUS303) Brass
Sensing surface
PBT (polybutylene terephthalate)
Accessories Instruction manual
E-29E2E
E2E
Characteristic data (typical)
Sensing Distance vs. Sensing ObjectE2E-X2D# E2E-X3D# E2E-X7D#
E2E-X10D# E2E-X4MD# E2E-X8MD#
E2E-X14MD# E2E-X20MD# E2E-X1R5Y#
3.0
2.5
2.0
1.5
1.0
0.5
0 5 10 15 20 25
Side length of sensing object d
Mild steel
Stainless steel(SUS304)
Brass
AluminumCopper
Dis
tanc
e X
(m
m)
#d t=1 mmX
4.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0 5 10 15 20 25 30 35 40
Dis
tanc
e X
(m
m)
Side length of sensing object d (mm)
Mild steel
Stainless steel(SUS304)
Brass
AluminumCopper
t=1 mmX
#d8
7
6
5
4
3
2
1
0 10 20 30 40 50
Side length of sensing object d (mm
Mild steel
Stainless steel(SUS304)
Brass
Aluminum
Copper
Dis
tanc
e X
(m
m)
#d t=1 mmX
12
10
8
6
4
2
0 10 20 30 40 50 60 70
Mild steel
Stainless steel(SUS304)
BrassAluminumCopper
Dis
tanc
e X
(m
m)
Side length of sensing object d (mm)
#dt=1 mm
X
6
5
4
3
2
1
0 10 20 30 40 50 60 70
Dis
tanc
e X
(m
m)
Side length of sensing object d (mm)
Mild steel
Stainless steel(SUS304)
BrassAluminumCopper
#d t=1 mmX
12
10
8
6
4
2
0 10 15 20 30 40 50 60 70
Mild steel
Stainless steel(SUS304)
Brass
AluminumCopper
Dis
tanc
e X
(m
m)
Side length of sensing object d (mm)
#dt=1 mm
X
25
20
15
10
5
0 10 20 30 40 50 60 70
Dis
tanc
e X
(m
m)
Side length of sensing object d (mm)
Mild steel
Stainless steel(SUS304)
BrassAluminumCopper
#d t=1 mmX
25
20
15
10
5
0 10 20 30 40 50 60 70 80 90 100
Side length of sensing object d (mm)
Mild steel
Stainless steel(SUS304)
BrassAluminumCopper
Dis
tanc
e X
(m
m)
t=1 mmX
#d
2.5
2.0
1.5
1.0
0.5
0 5 10 15 20 25
Mild steel
Stainless steel(SUS304)
Brass
Aluminum
Side length of sensing object d (mm)
#d t=1 mmX
Dis
tanc
e X
(m
m)
E-30 Proximity Sensors
E2E-X2Y# E2E-X5Y# E2E-X10Y#
E2E-X2MY# E2E-X5MY# E2E-X10MY#
E2E-X18MY# E2E-CR8# E2E-X1#/-C1#
2.5
2.0
1.5
1.0
0.5
0 5 10 15 20 25
Mild steel
Stainless steel(SUS304)
Brass
Aluminum
Dis
tanc
e X
(m
m)
Side length of sensing object d (mm)
#d t=1 mmX
7
6
5
4
3
2
1
0 10 20 30 40 50
Stainless steel (SUS304)
Mild steel
Brass
Aluminum
Dis
tanc
e X
(m
m)
Side length of sensing object d (mm)
t=1 mmX
#d
12
10
8
6
4
2
0 10 20 30 40 50 60
Dis
tanc
e X
(m
m)
Stainless steel (SUS304)
Mild steel
Brass
Aluminum
Side length of sensing object d (mm)
#d t=1 mmX
2.5
2.0
1.5
1.0
0.5
0 5 10 15 20 25 30
Mild steel
Stainless steel(SUS304)
Brass
Aluminum
Copper
Dis
tanc
e X
(m
m)
Side length of sensing object d (mm)
#d t=1 mmX
7
6
5
4
3
2
1
0 10 20 30 40 50
Stainless steel (SUS304)
Mild steel
Brass
Aluminum
Side length of sensing object d (mm)
Dis
tanc
e X
(m
m)
#d t=1 mmX
12
10
8
6
4
2
0 10 20 30 40 50 60
Stainless steel (SUS304)
Mild steel
Brass
Aluminum
Dis
tanc
e X
(m
m)
Side length of sensing object d (mm)
#d t=1 mmX
25
20
15
10
5
0 20 40 60 80 100
Stainless steel(SUS304)
Mild steel
Brass
Aluminum
Side length of sensing object d (mm)
Dis
tanc
e X
(m
m)
#d t=1 mmX
1.2
1.0
0.8
0.6
0.4
0.2
0 5 10 15 20 25 30
Stainless steel(SUS304)
Mild steel
Brass
AluminumCopper
Dis
tanc
e X
(m
m)
Side length of sensing object d (mm)
#dt=1 mm
X
#dt=1 mm
X
1.2
1.0
0.8
0.6
0.4
0.2
0 5 10 15 20 25
Stainless steel (SUS304)
Mild steel
Brass
Aluminum
Side length of sensing object d (mm)
Dis
tanc
e X
(m
m)
E-31E2E
E2E
Output Circuit Diagram
DC 2-wire Models (E2E-X#D#)
Operating status
Model Timing chart Output circuit
No self- diagnostics output, NO
E2E-X#D1-NE2E-X#D1-
M1G(J)E2E-X#D1-M3G
E2E-X#D1-M1J-T
No self- diagnostic output, NC
E2E-X#D2-NE2E-X#D2-M1GE2E-X#D2-M3G
With self- diagnostic output, NO
E2E-X#D1SE2E-X#D1S-M1
Sensing object
(%) 100 080
Rated sensing
distance
Stable sensing zoneNon-sensing zoneUnstablesensing zone
Setting position
Proximity sensor
Lit
Not lit
Lit
Not lit
ON
OFF
Settingindicator
(green)
Redindicator
Control output
LoadBrown
Blue
Maincircuit
+V
0V
Polarised
Note:The load can be connected to either the +V or 0-V side.
+V(0V)
0V(+V)
Load
Maincircuit
No polarity
Note:1. The load can be connected to either the +V or 0-V side.2. The E2E-X#D1-M1J-T has no polarity. Therefore, terminals 3 and 4 have no porality.
Sensingobject
(%) 100 0
Rated sensing
distance
Sensing zoneNon-sensing zone
Proximity sensor
Lit
Not lit
ON
OFF
Red indicator
Control output
LoadBrown
A
Blue
B
Maincircuit
+V
0V
Note:The load can be connected to either the +V or 0-V side.
Sensing object
(%) 100 080
Rated
sensingdistance
Stable sensing zoneNon-sensing zoneUnstablesensing zone
Setting position
Proximity sensor
Lit
Not lit
Lit
Not lit
ON
OFF
ON
OFF
Settingindicator
(green)
Red indicator
Control output
Diagostic Output(see note)
Note:The diagostic output is ON when there is coil burnout or the sensing object is located in the unstable sensing range for 0.3 s or more.
+V
+V
0V
LoadBrown
OrangeB(Diagnosis output)
BlueC
Maincircuit
Note:The load connects to the +V side both controloutput and self-diagostic output.
Load
D
E-32 Proximity Sensors
DC 3-wire
AC 2-wire Models
Operating status Output specifi-cations Model Timing chart Output circuit
NO
NPN open
collector output
E2E-C/X#C#
NC
NO
PNP open
collector output
E2E-C/X#B#
NC
Operating status Model Timing chart Output circuit
NO
E2E-X#Y#E2E-X#Y#-M1
NC
Yes
No
Lit
Not lit
ON
OFF
Red indicator
Sensing object
Control output Load
Brown
Black
Blue
100W
Main circuit
+V
0V
Yes
No
Lit
Not lit
ON
OFF
Red indicator
Sensing object
Control output
Yes
No
Lit
Not lit
ON
OFF
Red indicator
Sensing object
Control output
Load
Brown
Black
Blue100W
Maincircuit
+V
0VYes
No
Lit
Not lit
ON
OFF
Red indicator
Sensing object
Control output
Yes
No
Lit
Not lit
ON
OFF
Yellow indicator
Sensing object
Control outputbetween brownand black lines
Load
Brown 3 (or 1)
Blue 4 (or 2)
Main circuit
About connector type:NO type: 3 and 4NC type: 1 and 2
Yes
No
Lit
Not lit
ON
OFF
Red indicator
Sensing object
Control output
E-33E2E
E2E
Sensor I/O Connectors
ConnectorApplicable connector
Part numberApplicable proximity sensor
modeFigure No.*1
*1. Refer to the column of the following page "connection figure No." for connection of a proximity sensor and an I/O connector.
Screw ShapeCable length
M12
2 m
A XS2F-D421-DA0-AE2E-X#D1-M1G
1E2E-X#D1-M1GJ
B XS2F-D421-DC0-A E2E-X#D1-M1J-T 2
D XS2F-D421-D80-AE2E-X#D2-M1(G) 5
E2E-X#D1S-M1 4
E XS2F-A421-DB0-A E2E-X#Y1-M1 7
F XS2F-A421-D90-A E2E-X#Y2-M1 8
5 m
A XS2F-D421-GA0-AE2E-X#D1-M1G
1E2E-X#D1-M1GJ
B XS2F-D421-GC0-A E2E-X#D1-M1J-T 2
D XS2F-D421-G80-AE2E-X#D2-M1(G) 5
E2E-X#D1S-M1 4
E XS2F-A421-GB0-A E2E-X#Y1-M1 7
F XS2F-A421-G90-A E2E-X#Y2-M1 8
2 m
A XS2F-D422-DA0-AE2E-X#D1-M1G
1E2E-X#D1-M1GJ
B XS2F-D422-DC0-A E2E-X#D1-M1J-T 2
D XS2F-D422-D80-AE2E-X#D2-M1(G) 5
E2E-X#D1S-M1 4
E XS2F-A422-DB0-A E2E-X#Y1-M1 7
5 m
A XS2F-D422-GA0-AE2E-X#D1-M1G
1E2E-X#D1-M1GJ
B XS2F-D422-GC0-A E2E-X#D1-M1J-T 2
D XS2F-D422-G80-AE2E-X#D2-M1(G) 5
E2E-X#D1S-M1 4
E XS2F-A422-GB0-A E2E-X#Y1-M1 7
M8
2 m
G
XS3F-M421-402-AE2E-X#D1-M3G 3
E2E-X#D2-M3G 6
5 m XS3F-M421-405-AE2E-X#D1-M3G 3
E2E-X#D2-M3G 6
2 m XS3F-M422-402-AE2E-X#D1-M3G 3
E2E-X#D2-M3G 6
5 m XS3F-M422-405-AE2E-X#D1-M3G 3
E2E-X#D2-M3G 6
Straight type
L type
Straight type
L type
E-34 Proximity Sensors
Connection with a sensor I/O connector
* Please take note that it differs from the cable color of a proximity sensor.
Figure No.
Proximity SensorsSensor I/O Connectors Connection
TypeOperat-
ing statusModel
1DC 2-wire (IEC pin ar-rangement)
NO
E2E-X#D1-M1G(J)
2 DC 2-wire (No polarity)
E2E-X#D1-M1J-T
3 DC 2-wire (M8 connector)
E2E-X#D1-M3G
4DC 2-wire (diagnostic type)
E2E-X#D1S-M1
5DC 2-wire (IEC pin ar-rangement)
NC
E2E-X#D2-M1G
6 DC 2-wire (M8 connector) E2E-X#D2-M3G
7
AC 2-wire Models
NO E2E-X#Y1-M1
8 NC E2E-X#Y2-M1
XS2F-D42#-#A0-A
1: Straight type2: L type
D: Cable length 2 mG: Cable length 5 m
1
2
3
4
1
2
3
4
E2E
Mai
n cir
cuit
XS2F
Brown (+)
Blue (-)
XS2F-D42#-#C0-A
1: Straight type2: L type
D: Cable length 2 mG: Cable length 5 m
1
2
3
4
1
2
3
4
E2E XS2F
Brown (unused)
Blue (+) (-)Black (-) (+)
(see note)
Mai
n cir
cuit
XS3F-M42#-40#-A
1: Straight type2: L type
2: Cable length 2 m5: Cable length 5 m
1
2
3
4
1
2
3
4
E2E XS3F
Brown (+)White (unused)Blue (unused)Black (-)
(see note)
Mai
n ci
rcui
t
XS2F-D42#-#80-A
1: Straight type2: L type
D: Cable length 2 mG: Cable length 5 m
White (self-diagostic output) (+)Blue (0-V)
1
2
3
4
1
2
3
4
E2E
Mai
n ci
rcui
t
XS2F(see note)
Brown (unused)
Black (control output) (+)
XS2F-D42#-#80-A
1: Straight type2: L type
D: Cable length 2 mG: Cable length 5 m
White (-)Blue (unused)
E2E
Mai
n cir
cuit
XS2F(see note)
Brown (+)
Black (unused)
1
2
3
4
1
2
3
4
XS3F-D42#-40#-A
1: Straight type2: L type
2: Cable length 2 m5: Cable length 5 m
White (-)Blue (unused)
1
2
3
4
1
2
3
4
E2E
Mai
n ci
rcui
t
XS3F(see note)
Brown (+)
Black (unused)
XS2F-A42#-#B0-A
1: Straight type2: L type
D: Cable length 2 mG: Cable length 5 m
1
2
3
4
1
2
3
4
E2E
Mai
n cir
cuit
XS2F
BrownBlue
XS2F-A421-#90-A
D: Cable length 2 mG: Cable length 5 m
1
2
3
4
1
2
3
4
Blue (unused)Black (unused)
BrownWhite
E2E XS2F
Mai
n cir
cuit
(see note)
E-35E2E
E2E
Precautions
Design
Effects of Surrounding Metal
Provide a minimum distance between the Sensor and the surrounding metal as shown in the table below.
Effects of Surrounding Metal (unit: mm) (Relationship between Screw Sizes and Models)
CautionDo not short-circuit the load, otherwise E2E may
explode or burn.Do not impose an excessive voltage on E2E,
otherwise it may explode or burn.
ItemE2E-CR8#E2E-X1#E2E-C1#
Correct Use
Type Item M8 M12 M18 M30
DC 2-wireE2E-X#D#
Shielded
l 0
d 8 12 18 30
D 0m 4.5 8 20 40
n 12 18 27 45
Unshielded
l 12 15 22 30
d 24 40 70 90
D 12 15 22 30
m 8 20 40 70n 24 40 70 90
DC 3-wireE2E-X#B#/C#
AC 2-wire ModelsE2E-X#Y#
Shielded
l 0
d 8 12 18 30
D 0
m 4.5 8 20 40
n 12 18 27 45
Unshielded
l 6 15 22 30
d 24 40 55 90
D 6 15 22 30
m 8 20 40 70
n 24 36 54 90
Type Item 4 dia. M55.4 mm
dia.
DC 3-wireE2E-X#C/B#E2E-C#C/B#
Shielded
l 0
d 4 5 5.4
D 0m 2.4 3
n 6 8
I
mn
mD
d dia.
I
Type Model
4 mm dia.
Shielded
E2E-CR8C#E2E-CR8B1
M5 E2E-X1C#E2E-X1B1
5.4 mm dia.
E2E-C1C#E2E-C1B1
M8Shielded E2E-X2D#
E2E-X1R5Y#
Unshielded E2E-X4MD#E2E-X2MY#
M12Shielded E2E-X3D#
E2E-X2Y#
Unshielded E2E-X8MD#E2E-X5MY#
M18Shielded E2E-X7D#
E2E-X5Y#
Unshielded E2E-X14MD#E2E-X10MY#
M30Shielded E2E-X10D#
E2E-X10Y#
Unshielded E2E-X20MD#E2E-X18MY #
E-36 Proximity Sensors
Mounting
Mounting
Do not tighten the nut with excessive force.
A washer must be used with the nut.
Note: 1 .The table below shows the tightening torques for part A and part Bnuts. In the previous examples, the nut is on the sensor head side (partB) and hence the tightening torque for part B applies. If this nut is inpart A, the tightening torque for part A applies instead.
2 .Following table bolting permission intensity shows the value at thetime of using a washer.
How to attach a pillar-screwless type (E2 E-CR8, -C1).
If you use a set screw, please increase the below bolting
torque by 0.2 Nm.
(E2E-C1: 0.4 Nm max.)
Mutual Interference
When installing two or more Sensors
face to face or side by side, ensure that
the minimum distances given in the
right-side tables are maintained.
A
B
Inrush Current
A load that has a large inrush current (e.g., a lamp or motor) will damage the Proximity Sensor, in such case connect the load to
the Proximity Sensor by means of a relay.
Mutual Interference
Note: Values in parentheses: Using a different frequency type model value.
Type Item M8 M12 M18 M30
DC 2-wireE2E-X#D#
ShieldedA 20 30 (20) 50 (30) 100(50)
B 15 20(12) 35 (18) 70(35)
UnshieldedA 80 120(60) 200(100) 300(100)
B 60 100(50) 110(60) 200(100)
AC 2-wire ModelsE2E-X#Y#
ShieldedA 20 30 (20) 50 (30) 100(50)
B 15 20(12) 35 (18) 70(35)
UnshieldedA 80 120(60) 200(100) 300(100)
B 60 100(50) 110(60) 200(100)
Type Item 4 mm dia. M55.4 mm
dia.
DC 3-wireE2E-X#C/B#E2E-C#C/B#
ShieldedA 20
B 15
Type
Part A Part B
Length (mm)Tensile strength (torque)
Tensile strength (torque)
M5 1 Nm
M8Shielded 9
9 Nm 12 NmUnshielded 3
M12 30 Nm
M18 70 Nm
M30 180 Nm
Part B Part A Part B Part A
<Shielded type> <Unshielded type> M3 hole
No screw is provided with the E2E-CR8 or E2E-C1. Please prepare it separatly.
8 to 21 mm
E-37E2E
E2E
Dimensions (Unit: mm)
SensorsModels and dimensions chart
Note: 1 .Two clamping nuts and one toothed washer are attached to M8 to M30 type.2 .The pre-wired models of M8 to M30 mark model number to a cable and a milling cutter by laser.
Type DC 2-wire DC 3-wire AC 2-wire Models
Model Shielded ModelFig-ure No.
ModelFig-ure No.
ModelFig-ure No.
Pre-wired
Shielded
4 mm dia.
---
E2E-CR8# 1
---M5 E2E-X1# 3
5.4 mm dia. E2E-C1# 2
M8 E2E-X2D# 4
---
E2E-X1R5Y# 6
M12 E2E-X3D# 8 E2E-X2Y# 10
M18 E2E-X7D# 13 E2E-X5Y# 13
M30 E2E-X10D# 15 E2E-X10Y# 15
Unshielded
M8 E2E-X4MD# 5
---
E2E-X2MY# 7
M12 E2E-X8MD# 9 E2E-X5MY# 11
M18 E2E-X14MD# 14 E2E-X10MY# 14
M30 E2E-X20MD# 16 E2E-X18MY# 16
Connector (M12)
Shielded
M8 E2E-X2D#-M1(G) 17
---
---
M12 E2E-X3D#-M1(G) 19 E2E-X2Y#-M1 21
M18 E2E-X7D#-M1(G) 23 E2E-X5Y#-M1 23
M30 E2E-X10D#-M1(G) 25 E2E-X10Y#-M1 25
Unshielded
M8 E2E-X4MD#-M1(G) 18
---
---
M12 E2E-X8MD#-M1(G) 20 E2E-X5MY#-M1 22
M18 E2E-X14MD#-M1(G) 24 E2E-X10MY#-M1 24
M30 E2E-X20MD#-M1(G) 26 E2E-X18MY#-M1 26
Connector(M8)Shielded
M8E2E-X2D#-M3G 27 ---
---Unshielded E2E-X4MD#-M3G 28 ---
Connector extension
Shielded
M12 E2E-X3D1-M1GJ 29
--- ---M18 E2E-X7D1-M1GJ 31
M30 E2E-X10D1-M1GJ 33
Unshielded
M12 E2E-X8MD1-M1GJ 30
--- ---M18 E2E-X14MD1-M1GJ 32
M30 E2E-X20MD1-M1GJ 34
Connector extension (no polarity)
^
M12 E2E-X3D1-M1J-T 29
--- ---M18 E2E-X7D1-M1J-T 31
M30 E2E-X10D1-M1J-T 33
Pre-wired Models (Shielded)
CAD file E2E_02fig.1 E2E-CR8#
4 dia.25
17.5
Indicator(see note)
Note:Round vinyl-insulated cable (oil-and vibration-resistive), 0.14 mm2, 3 corStandard length: 2 m,The cable can be extended up to 100 m
CAD file E2E_01fig.2 E2E-C1#
5.4 dia.25
17.5
Indicator(see note)
Note:Round vinyl-insulated cable (oil-and vibration-resistive), 0.14 mm2, 3 cores Standard length: 2 m,The cable can be extended up to 100 m
Mounting Holes
F
Outer diameter 4 mm dia. 5.4 mm dia.
F (mm) 4.2 dia.+0.5 5.7 dia.+0.500
E-38 Proximity Sensors
F
Dimensions
F (mm) 5.5 dia.+0.5 0
M5
8.5 dia.+0.5 0
M8
12.5 dia.+0.5 0
M12
Pre-wired Models (Shielded)
4
8 15
25
17.59.7 dia.
M5 x 0.5Indicator
Two clamping nutTwo toothed washers
(see note)
Note: Round vinyl-insulated cable (oil-and vibration-resistive), 0.14 mm2, 3 cores 2.9 dia.Standard length: 2 m,The cable can be extended up to 100 m
fig.3 E2E-X1# CAD file E2E_19
Pre-wired Models (Unshielded)
15 dia.313
26
8
730
M8 x 1Operation indicator
Two clamping nutToothed washers
(see note)
Note: Round vinyl-insulated cable 4 dia. (0.08 dia. x 60), 2/3 cores 4 dia. (0.08 dia x 6/10) for robotics cable modelsStandard length: 2 m
fig.4 E2E-X2D# Model CAD fileE2E-X2D# E2E_26
15 dia.
6.1 dia.
3613
26
8
730
M8 x 1Operation indicator
Two clamping nutTwo toothed washers
(see note)
Note: Round vinyl-insulated cable 4 dia. (0.08 dia. x 60), 2/3 cores 4 dia. (0.08 dia. x 6/10) for robotics cable modelsStandard length: 2 m
Model CAD fileE2E-X4MD# E2E_40
fig.5 E2E-X4MD#
CAD file E2E_21fig.6 E2E-X1R5Y#
15 dia.313
36
8
740
M8 x 1Operation indicator
Two clamping nutToothed washers
(see note)
Note:Round vinyl-insulated cable 4 dia. (0.08 dia x 60), 2 coresStandard length: 2 m
CAD file E2E_31fig.7 E2E-X2MY#
15 dia.
6.1 dia.
3613
36
8
740
M8 x 1Operation indicator
Two clamping nutToothed washers
(see note)
Note:Round vinyl-insulated cable 4 dia. (0.08 dia x 60), 2 coresStandard length: 200 m
21 dia.
417
33
10
938
M12 x 1Operation indicator
Two clamping nutToothed washers
(see note)
Note: Round vinyl-insulated cable 4 dia. (0.08 dia. x 60), 2/3 cores4 dia. (0.08 dia. x 6/10) for robotics cable modelsStandard length: 2 m
fig.8 E2E-X3D# Model CAD fileE2E-X3D# E2E_37
fig.9 E2E-X8MD# Model CAD fileE2E-X8MD# E2E_55
21 dia.
9 dia.
4717
33
10
938
M12 x 1 Operation indicatorTwo clamping nut
Two toothed washers
(see note 1)
Note: Round vinyl-insulated cable 4 dia. (0.08 dia. x 60), 2/3 cores4 dia. (0.08 dia x 6/10) for robotics cable modelsStandard length: 2 m
E-39E2E
E2E
Pre-wired Models (Shielded) Pre-wired Models (Unshielded)
fig.13 E2E-X7D#/E2E-X5Y# fig.14 E2E-X14MD#/E2E-X10MY#
fig.15 E2E-X10D#/E2E-X10Y# fig.16 E2E-X20MD#/E2E-X18MY#
CAD file E2E_32fig.10 E2E-X2Y#
21 dia.
417
38
10
943
M12 x 1Operation indicator
Two clamping nutToothed washer
(see note)
Note:Round vinyl-insulated cable 4 dia. (0.08 dia. x 60), 2 coresStandard length: 2 m
CAD file E2E_46fig.11 E2E-X5MY#
21 dia.
9 dia.
4717
38
10
943
M12 x 1 Operation indicatorTwo clamping nut
Toothed washer
(see note)
Note:Round vinyl-insulated cable 4 dia. (0.08 dia. x 60), 2 coresStandard length: 2 m
M18 x 1Operation indicator
Two clamping nutToothed washer
(see note)
29 dia.
24 4
38
10
1243
Note:Round vinyl-insulated cable 4 dia. (0.12 dia. x 45), 2/3 cores6 dia. (0.08 dia. x 6/17) for robotics cable modelsStandard length: 2 m
Model CAD fileE2E-X7D# E2E_42E2E-X5Y# E2E_48
14.8 dia.(see note 1)
Note: Round vinyl-insulated cable 6 dia. (0.12 dia. x 45), 2/3 cores6 dia. (0.08 dia. x 6/17) robotics cable modelsStandard length: 2 m
Operation indicatorM18 x 1 Two clamping nut
Toothed washer
29 dia.
24 4
38
10
1243
10
Model CAD fileE2E-X14MD# E2E_16E2E-X10MY# E2E_10
M30 x 1.5
Operation indicator
Two clamping nutToothed washer
(see note)
42.dia.
36 5
43
10
1248
Note:Round vinyl-insulated cable 4 dia. (0.12 dia. x 45), 2/3 cores6 dia. (0.08 dia. x 6/17) for robotics cable modelsStandard length: 2 m
Model CAD fileE2E-X10D# E2E_07E2E-X10Y# E2E_06
26.8 dia.
M30 x 1.5
(see note)
Note:Round vinyl-insulated cable 4 dia. (0.12 dia. x 45), 2/3 cores6 dia. (0.08 dia. x 6/17) for robotics cable modelsStandard length: 2 m
Operation indicator
Two clamping nutToothed washer
42 dia.
36 5
43
13 10
1248
Model CAD fileE2E-X20MD# E2E_25E2E-X18MY# E2E_17
E-40 Proximity Sensors
M8 Connector Models (Shielded)
M8 Connector Models (Unshielded)
fig.27 E2E-X2D#-M3G fig.28 E2E-X4MD#-M3G
M12 Connector Models (Shielded)
M12 Connector Models (Unshielded)
fig.17 E2E-X2D#-M1(G) fig.18 E2E-X4MD#-M1(G)
15 dia.
313
26
8
3139
M8 x 1
M8 x 1
Operation indicator
Toothed washerTwo clamping nut
CAD file E2E_59
15 dia.
6.1 dia.
3613
26
8
31
39
M8 x 1
M8 x 1
Operation indicator
Toothed washerTwo clamping nut
CAD file E2E_60
15 dia.
313
26
8
3043
M8 x 1
M12 x 1
Operation indicator
Toothed washerTwo clamping nut
CAD file E2E_27
15 dia.
6.1 dia.
3613
26
8
30
43
M8 X 1
M12 X 1
Operation indicatorTwo clamping nutToothed washer
CAD file E2E_41
E-41E2E
E2E
fig.19 E2E-X3D#-M1G fig.20 E2E-X8MD#-M1G
fig.21 E2E-X2Y#-M1 fig.22 E2E-X5MY#-M1
fig.23 E2E-X7D#-M1G/E2E-X5Y#-M1 fig.24 E2E-X14MD#-M1(G)/E2E-X10MY#-M1
fig.25 E2E-X10D#-M1(G)/E2E-X10Y#-M1 fig.26 E2E-X20MD#-M1(G)/E2E-X18MY#-M1
21 dia.
417
33
10
48
M12 x 1
M12 x 1
Operation indicator
Toothed washerTwo clamping nut
CAD file E2E_34
21 dia.
9 dia.
4717
33
10
48
M12 x 1
M12 x 1
Operation indicator
Toothed washerTwo clamping nut
CAD file E2E_57
21 dia.
417
38
10
53
M12 x 1
M12 x 1
Operation indicator
Toothed washers
Two clamping nut
CAD file E2E_33
29 dia.
9 dia.
4717
38
10
53
M12 x 1
M12 x 1
Operation indicator
Toothed washerTwo clamping nut
CAD file E2E_47
29 dia.
424
38
10
53
M18 x 1
M12 x 1
Operation indicator
Two clamping nut
Toothed washer
CAD file E2E_49
29 dia.
14.8 dia.
41024
38
10
53
M18 x 1
M12 x 1
Operation indicator
Toothed washerTwo clamping nut
CAD file E2E_14
42 dia.
536
43
10
58
M30 x 1.5
M12 x 1Operation indicator
Two clamping nut
Toothed washer
CAD file E2E_04
42 dia.
26.8 dia.
51336
43
10
58
M30 x 1.5
M12 x 1Operation indicator
Two clamping nut
Toothed washer
CAD file E2E_23
Dimensions
F (mm) 5.5 dia.0.5 0 12.5 dia.0.5
0 18.5 dia.0.5 0 30.5 dia.0.5
0
M5
8.5 dia.0.5 0
M8 M12 M18 M30
F
Mounting Holes
E-42 Proximity Sensors
Connector Extension Models (Shielded) Mounting Holes
F
Dimensions
F (mm) 12.5 dia.+0.5 0
M12
18.5 dia.+0.5 0
M18
30.5 dia.+0.5 0
M30
fig.29 E2E-X3D1-M1GJE2E-X3D1-M1J-T 21 dia.
417
33
10
(see note)
38 9
M12 x 1
M12 x 1
Operation indicator
Toothed washerTwo clamping nut Note:
Round vinyl-insulated cable 4 dia. (0.08 dia. x 60)Standard length: 0.3 m
CAD file E2E_36
fig.31 E2E-X7D1-M1GJE2E-X7D1-M1J-T 29 dia.
424
38
10
(see note)
43 12
M18 x 1
M12 x 1
Operation indicator
Toothed washer
Two clamping nut Note:Round vinyl-insulated cable 6 dia. (0.12 dia. x 45)Standard length: 0.3 m
CAD file E2E_52
fig.33 E2E-X10D1-M1GJE2E-X10D1-M1J-T 42 dia.
536
43
10
(see note)
48 12
M30 x 1.5
M12 x 1
Operation indicator
Toothed washer
Two clamping nut Note:Round vinyl-insulated cable 6 dia. (0.12 dia. x 45)Standard length: 0.3 m
CAD file E2E_05
E-43E2E
E2E
Dimensions of connection with proximity sensor and sensor I/O connector
Accessories (Order Separately)
Sensor I/O ConnectorsE-33
Connector Extension Models (Unshielded)
fig.30 E2E-X8MD1-M1GJ21 dia.
9 dia.
4717
33
10
(see note)
38 9
M12 x 1
M12 x 1
Operation indicator
Toothed washerTwo clamping nut Note:
Round vinyl-insulated cable 4 dia. (0.08 dia. x 60)
Standard length: 0.3 m
CAD file E2E_58
fig.32 E2E-X14MD1-M1GJ
CAD file E2E_15
29 dia.
14.8 dia.
410
24
38
10
(see note)
43 12
M18 x 1
M12 x 1
Operation indicator
Toothed washerTwo clamping nut Note:
Round vinyl-insulated cable 6 dia. (0.12 dia. x 45)Standard length: 0.3 m
fig.34 E2E-X20MD1-M1GJ
CAD file E2E_24
42 dia.
26.8 dia.
51336
43
10
(see note)
48 12
M30 x 1.5
M12 x 1
Operation indicator
Toothed washer
Two clamping nut Note:Round vinyl-insulated cable 6 dia. (0.12 dia. x 45)Standard length: 0.3 m
L1
L2 L2
L1
<Straight type connection>
<L type connection>
<Straight type connection>
<L type connection>
Shielded Unshielded Dimensions of connection with XS2F
Dimensions of connection with XS3F
LengthL1 L2Size
M8 Approx.75 Approx.62
M12*DC Models Approx.80 Approx.67
AC Models Approx.85 Approx.72
M18 Approx.85 Approx.72
M30 Approx.90 Approx.77
Length L1 L2Size
M8 Approx.65 Approx.54
* Only in the diameter M12of a sensor, dimensions(sensor full length) differfor AC or DC. Therefore,please consider that a con-nection with I/O connectorchanges dimensions.
E-44 Proximity Sensors
Cylindrical Proximity Sensor
E2ELA new series of easy-to-usemodels for standard- anddouble-distance• Smooth 6,5mm diameter barrel• Stainless steel or brass housing
Ordering Information
Cable types
Brass housing
Stainless steel housing
Plug types
Brass housing
Diameter Length MountingSensing Distance
OutputNPN / NO NPN / NC PNP / NO PNP / NC
Ø 6,5
30 mm Shielded 1,5 mm E2EL-C1R5E1 2M E2EL-C1R5E2 2M E2EL-C1R5F1 2M E2EL-C1R5F2 2M
32 mm Non-shielded 2,0 mm E2EL-C2ME1 2M E2EL-C2ME2 2M E2EL-C2MF1 2M E2EL-C2MF2 2M
45 mm Shielded 1,5 mm E2EL-C1R5E1-L 2M E2EL-C1R5E2-L 2M E2EL-C1R5F1-L 2M E2EL-C1R5F2-L 2M
47 mm Non-shielded 2,0 mm E2EL-C2ME1-L 2M E2EL-C2ME2-L 2M E2EL-C2MF1-L 2M E2EL-C2MF2-L 2M
Diameter Length MountingSensing Distance
OutputNPN / NO NPN / NC PNP / NO PNP / NC
Ø 6,530 mm Shielded 2,0 mm E2EL-C2E1-DS 2M E2EL-C2E2-DS 2M E2EL-C2F1-DS 2M E2EL-C2F2-DS 2M
45 mm Shielded 2,0 mm E2EL-C2E1-DSL 2M E2EL-C2E2-DSL 2M E2EL-C2F1-DSL 2M E2EL-C2F2-DSL 2M
Diameter Length MountingSensing Distance
OutputNPN / NO NPN / NC PNP / NO PNP / NC
Ø 6,5 / Plug M8
45 mm Shielded 1,5 mm E2EL-C1R5E1-M3 E2EL-C1R5E2-M3 E2EL-C1R5F1-M3 E2EL-C1R5F2-M3
47 mm Non-shielded 2,0 mm E2EL-C2ME1-M3 E2EL-C2ME2-M3 E2EL-C2MF1-M3 E2EL-C2MF2-M3
54 mm Shielded 1,5 mm E2EL-C1R5E1-M3L E2EL-C1R5E2-M3L E2EL-C1R5F1-M3L E2EL-C1R5F2-M3L
56 mm Non-shielded 2,0 mm E2EL-C2ME1-M3L E2EL-C2ME2-M3L E2EL-C2MF1-M3L E2EL-C2MF2-M3L
E-45E2EL
E2E
L
Specifications
Brass type
Type Ø 6,5Operating voltage 10 to 35 VDCRated supply voltage 24 VDCCurrent consumption max. 15 mA at 24 VDCSensing object Ferrous metalsMounting ((s)hielded, (n)on-shielded) *1
*1. For detailed mounting instruction please refer to page E-49
s nOperating distance in mm 1,5 2,0Tolerance of operating distance ±10%Standard target size in mm (L x W x H in mm, FE 37) 6,5x6,5x1Differential travel 1 % ... 15 % of operating distanceMax. response frequency in kHz 5,0
Control output
Type
E2EL-... E1 type: NPN-NOE2 type: NPN-NCF1 type: PNP-NOF2 type: PNP-NC
Max-Load 200 mAMax-on-stateVoltage drop
2,5 VDC (at 200mA load current and with 2 m cable)
Circuit protection Reverse polarity, output short-circuitIndicator Operating indicator (yellow LED)Ambient temperature Operating: -25° to 70°CHumidity 35 to 95 % RHInfluence of temperature ± 10 % max. of Sn at 23°C in temperature range of -25° to 70°C
Dielectric strength1.500 VAC, 50/60 Hz for 1 min. between current carry parts and case
Electromagnetic compatibility EMC EN 60947-5-2
Vibration resistanceDestruction: 10 to 70 Hz, 1,5 mm double amplitude for 1 hour each in X, Y and Z directions
Shock resistanceDestruction: 300 m/s² (approx. 30 G) for 6 times each in X, Y and Z directions
Enclosure rating IP 67 (EN 60947-1)
Connection *2
*2. PUR cable and different length on request.
Pre-wired 2 m PVC-cable, 3 x 0,14 mm²Connector M8 plug
Weight in gPre-wired
long 45short 43
Connectorlong 10short 8
MaterialCase BrassSensing face PBTP
E-46 Proximity Sensors
Stainless steel type
Type Ø 6,5Operating voltage 10 to 35 VDCRated supply voltage 24 VDCCurrent consumption max. 15 mA at 24 VDCSensing object Ferrous metalsMounting *1
*1. For detailed mounting instruction please refer to page E-49
shieldedOperating distance in mm 2,0Tolerance of operating distance ±10%Standard target size in mm (L x W x H in mm, FE 37) 6,5x6,5x1Differential travel 1 % ... 15 % of operating distanceMax. response frequency in kHz 4,0
Control output
Type
E2EL-... E1 type: NPN-NOE2 type: NPN-NCF1 type: PNP-NOF2 type: PNP-NC
Max-Load 200 mAMax-on-stateVoltage drop
2,5 VDC (at 200mA load current and with 2 m cable)
Circuit protection Reverse polarity, output short-circuitIndicator Operating indicator (yellow LED)Ambient temperature Operating: -25° to 70°CHumidity 35 to 95 % RHInfluence of temperature ± 10 % max. of Sn at 23°C in temperature range of -25° to 70°C
Dielectric strength1.500 VAC, 50/60 Hz for 1 min. between current carry parts and case
Electromagnetic compatibility EMC EN 60947-5-2
Vibration resistanceDestruction: 10 to 70 Hz, 1,5 mm double amplitude for 1 hour each in X, Y and Z directions
Shock resistanceDestruction: 300 m/s² (approx. 30 G) for 6 times each in X, Y and Z directions
Enclosure rating IP 67 (EN 60947-1)
Connection *2
*2. PUR cable and different length on request.
Pre-wired 2 m PVC-cable, 3 x 0,14 mm²Connector -
Weight in gPre-wired
long 45short 43
Connectorlong -short -
MaterialCase stainless steel 1.4305 / AISI 303Sensing face PBTP
E-47E2EL
E2E
L
Engineering data
Standardized characteristic for lateral approach
Output Circuit Diagram and Timing Chart
Pin Arrangement at Connector Types
0
0,2
0,4
0,6
0,8
1
1,2
-1 -0,8 -0,6 -0,4 -0,2 0 0,2 0,4 0,6 0,8 1
lateral distance related to radius of 'active surface' (r/ract)
standard target axial
approach
lateral approach
off
'switch-on' curve
' switch-off' curve
axia
l dis
tan
ce r
elat
ed t
o e
ffec
tive
op
erat
ing
dis
tan
ce(s
/sr)
on
E2EL-C@E@ NPN Output
E2EL-C@F@PNP Output
Main circuit
Brown 1
Blue 3
Load
Black 4 (or 2)
Blue 3
Load
Black 4 (or 2)
Brown 1
0 V
Main circuit
4,7 kW
4,7 kW
Sensing object
Yellow indicator
Control output
YesNo
ONOFF
LitNot lit
NO NC
E2EL-C@E@NPN Output
Sensing object
Yellow indicator
Control output
YesNo
ONOFF
LitNot lit
NO NC
E2EL-C@F@PNP Output
Connector M8 (viewed to plug pins)
Output
+ -
E-48 Proximity Sensors
Dimensions
Cable types
Plug types
E2EL-C1@R5 2M, E2EL-C2@-DS 2M E2EL-C2M@ 2M
E2EL-C1R5@-L 2M, E2EL-C2@-DSL 2M E2EL-C2M@-L 2M
E2EL-C1R5@-M3 E2EL-C2M@-M3
E2EL-C1R5@-M3L E2EL-C2M@-M3L
E-49E2EL
E2E
L
Installation
Caution
Correct Use
Installation
Power Reset Time
The Proximity Sensor is ready to operate within 100 ms after power is supplied. If power supplies are connected to the Proxim-ity Sensor and load respectively, be sure to supply power to the Proximity Sensor before supplying power to the load.
Power OFF
The Proximity Sensor may output a pulse signal when it is turned off. Therefore, it is recommended to turn off the load before turn-ing off the Proximity Sensor.Power Supply Transformer
When using a DC power supply, make sure that the DC power supply has an insulated transformer. Do not use a DC power sup-ply with an auto-transformer.
Sensing Object
Metal Coating:The sensing distance of the Proximity Sensor vary with the metal coating on sensing objects.
Wiring
High-tension Lines
Wiring through Metal ConduitIf there is a power or high-tension line near the cord of the Prox-imity Sensor, wire the cord through an independent metal conduit to prevent against Proximity Sensor damage or malfunctioning.
Core Tractive Force
Do not pull cords with the tractive force exceeding the following: pull force (N) = 20 x cable diameter ( mm)
Mounting
The Proximity Sensor must not be subjected to excessive shock with a ha mmer when it is installed, otherwise the Proximity Sen-sor may be damaged or lose the water-resistivity.
Environment
Water-Resistivity
Do not use the Proximity Sensor underwater, outdoors or in the rain.
Operating Environment
Be sure to use the Proximity Sensor within operating ambient temperature range and do not use the Proximity Sensor outdoors so that its reliability and life expectancy can be maintained. Al-though the Proximity Sensor is water resistive, a cover to protect the Proximity Sensor from water or soluble machining oil is reco mmended so that its reliability and life expectancy can be main-tained. Do not use the Proximity Sensor in an environment with chemical gas (e. G., strong alkaline or acid gases including nitric, chromic, and concentrated sulfuric acid gases).
Item Examples
Power SupplyDo not impose an excessive voltage on the E2EL, otherwise it may explode or burn. Do not impose 24 VAC on any E2EL model, otherwise it may ex-plode or burn.
Load short-circuitDo not short-circuit the load, or the E2EL may explode or burn.The E2EL’s short-circuit protection function is valid, if the polarity of the supply voltage imposed is incorrect and within the rated voltage range.
WiringBe sure to wire the E2EL and load correctly, otherwise it may ex-plode or burn.
E-50 Proximity Sensors
Effects of Surrounding Metal
Shielded types:
Shielded types allow direct installation on metal plates in an em-bedded manner without performance change. A minimum dis-tance of 3sn is required between the active surface and a metallic surface in front of the device. (Fig. 1).For SUS shielded types the following minimum distances are re-quired to avoid performance change (see Fig.2 and table below):
Fig.1: Shielded type (except SUS)
Fig.2: Shielded SUS type
Non-shielded types:
Installation of non-shielded types in metal require the minimum distances according to Fig. 3.
Fig.3: Non-shielded type
Item Examples ItemAND (serial connection) The Sensors connected together must satisfy the
following conditions: iL + (N-1) x i = Upper-limit of control output of each
SensorVS - N x VR = Load operating voltageN = No. of SensorsVR = Residual voltage of each SensorVS = Supply voltagei = Current consumption of the SensoriL = Load currentIf the MY Relay, which operate at 24 VDC, is used as a load for example, a maximum of two Proximity Sensors can be connected to the load.
OR (parallel connection) The number of Sensors connected in parallel varies with the Proximity Sensor model.
Shielded SUS Types Free zoneE2EL-C2@-DS 0,5 mm
≥3sn
≥3snFreezone
d
≥3sn ≥2sn
≥3d
MEMO
E-51E2EL
E2E
L
E-52 Proximity Sensors
Proximity sensors
TLCylindrical all-metal housing with M8 plug connection or pre-wired
Ordering information
Short barrel type
Long barrel type (CENELEC)
Specifications
VersionsSn (mm)
OutputNPN PNP
Size Type NO NC NO NC
8 mmShielded
Connector1.5
TL-C1R5E1-M3-E1 TL-C1R5E2-M3-E1 TL-C1R5F1-M3-E1 TL-C1R5F2-M3-E1Pre-wired TL-C1R5E1-E1 TL-C1R5E2-E1 TL-C1R5F1-E1 TL-C1R5F2-E1
Non-shieldedConnector
2TL-C2ME1-M3-E1 TL-C2ME2-M3-E1 TL-C2MF1-M3-E1 TL-C2MF2-M3-E1
Pre-wired TL-C2ME1-E1 TL-C2ME2-E1 TL-C2MF1-E1 TL-C2MF2-E1
VersionsSn (mm)
OutputNPN PNP
Size Type NO NC NO NC
8 mmShielded
Connector1.5
TL-C1R5E1-M3-E2 TL-C1R5E2-M3-E2 TL-C1R5F1-M3-E2 TL-C1R5F2-M3-E2Pre-wired TL-C1R5E1-E2 TL-C1R5E2-E2 TL-C1R5F1-E2 TL-C1R5F2-E2
Non-shieldedConnector
2TL-C2ME1-M3-E2 TL-C2ME2-M3-E2 TL-C2MF1-M3-E2 TL-C2MF2-M3-E2
Pre-wired TL-C2ME1-E2 TL-C2ME2-E2 TL-C2MF1-E2 TL-C2MF2-E2
Type8 mm ØTL-C1R5@@-E1TL-C1R5@@-E2
TL-C2M@@-E1TL-C2M@@-E2
Sensing distance (Sn) 1.5 mm ± 10% 2 mm ± 10%Power supply 10 to 35 V DCPower consumption 15 mA max.Object St 37 8 x 8 x 1 mmSwitching hysteresis 1 to 15 %Switching frequency 5 kHzTemperature dependency 10% max.Ambient temperature -25° to 70° CSwitching output 300 mA max.Residual voltage 2.5 V max.Function display 1 LEDDegree of protection IP 65Housing material Nickel-plated brass
E-53TL
TL
Output circuits
Reduction factors (typical values)
Dimensions (mm)
Chrome-nickel Sn x 0.9Brass Sn x 0.5Aluminium Sn x 0.45Copper Sn x 0.4
PNP output
+
A
Load
-
Circuit
A
NPN output
Circuit
Load
+
-
A
+ -
TL-C1R5@@-E1
TL-C2M@@-E1
TL-C1R5@@-E2
TL-C2M@@-E2
E-54 Proximity Sensors
InstallationThe minimum clearances indicated below must always be maintained in the case of non-shielded mounted types.
Installation accessories
Type d1 d2 d3 L1 L2 w h d MaterialY92E-B8-E1 8.0 6.0 3.2 7.5 3.3 20 12 16 Brass Y92E-B8-E2 8.0 6.0 3.2 7.5 3.3 20 14 16 Plastic
3d
d
2Sn
3Sn 2d
d
3Sn
d
2Sn
d d
b
L2
hd1
d3
d2
L1t
MEMO
E-55TL
TL
E-56 Proximity Sensors
Spatter immune Proximity Sensors
E2EQA Series of Spatter-resistantProximity Sensors with a Teflon-coated Metal Housing Long sensing-distance type included in series.
* Teflon is a registered trademark of Dupont Company and Mitsui Du-pont Chemical Company for their fluoride resin.
Ordering Information
Sensors Pre-wired ModelsLong-distance type
Standard
Plug-in ModelsLong-distance type
Standard
Shape Sensing distanceOutput
specificationsOperating
statusModel
M12
DC 2-wire NO
E2EQ-X4X1
M18 E2EQ-X8X1
M30 E2EQ-X15X1
Shape Sensing distanceOutput
specificationsOperating
statusModel
M12
DC 2-wire NO
E2EQ-X3D1
M18 E2EQ-X7D1
M30 E2EQ-X10D1
Shape Sensing distanceOutput
specificationsOperating
statusModel
M12DC 2-wire models (3) and (4) Pin arrangement
NO
E2EQ-X4X1-M1J
M18 E2EQ-X8X1-M1J
M30 E2EQ-X15X1-M1J
Standard Sensing distanceOutput
specificationsOperating
statusModel
M12DC 2-wire models (1) and (4) Pin ar-rangement
NO
E2EQ-X3D1-M1GJ
M18 E2EQ-X7D1-M1GJ
M30 E2EQ-X10D1-M1GJ
Shielded4mm
8mm
15mm
Shielded3mm
7mm
10mm
Shielded4mm
8mm
15mm
Shielded3mm
7mm
10mm
E-57E2EQ
E2E
Q
Accessories (Order Separately)Sensor I/O Connectors
Rating/Performance
Long-distance type
Shape Cable length Sensor I/O Connectors Applicable proximity sensor models
2 m XS2F-D421-DCO-A
E2EQ-X#X1-M1J5 m XS2F-D421-GCO-A
2 m XS2F-D422-DCO-A
5 m XS2F-D422-GCO-A
2 m XS2F-D421-DA0-A
E2EQ-X#D1-M1GJ5 m XS2F-D421-GA0-A
2 m XS2F-D422-DA0-A
5 m XS2F-D422-GA0-A
Model E2EQ-X4X1E2EQ-X4X1-M1J
E2EQ-X8X1E2EQ-X8X1-M1J
E2EQ-X15X1E2EQ-X15X1-M1JItem
Sensing distance 4 mm ±10% 8 mm ±10% 15 mm ±10%
Setting distance*1
*1. Use within a range where the green indicator is lit.
0 to 3.2 mm 0 to 6.4 mm 0 to 12 mm
Differential distance 15% max. of sensing distance
Standard sensing object (mild steel)
12 x 12 x 1 mm 18 ± 18 ± 1 mm 30 ± 30 ± 1 mm
Response frequency*2
*2. The response frequencies for DC switching are average values.
1 kHz 0.5 kHz 0.25 kHz
Control output
Switching capacity
3 to 100 mA
Residual voltage*3
*3. Since residual voltage is 5 V, use it after checking interface requirements with the connection devices.
5.0 V max. (under load current of 100 mA with cable length of 2 m)
Operating status (with sensing object approaching)
C1 models: NO
Protective circuits Surge absorber, load short-circuit protection
Ambient temperature Operating: -25°C to 70°C, Storage: -40°C to 85°C (with no icing or condensation)
Temperature influence±15% max. of sensing distance at 23°C within temperature range of -40°C to 85°C ±10% max. of sensing distance at 23°C within temperature range of -25°C to70°C
±15% max. of sensing distance at 23°C within temperature range of -25°C to 70°C
Voltage influence ±1% max. of Sensing distance in rated voltage range ±15%.
Shock resistance Destruction: 1,000 m/s2 for 10 times each in X, Y, and Z directions
Connection method Pre-wired (standard length: 2 m) Connector Extension Models
Weight (Packed state)
Pre-wired 65 g Approx. 140 g Approx. 190 g
Junction connector
Approx. 20 g Approx. 40g Approx. 90 g
Straight type
L type
Straight type
L type
E-58 Proximity Sensors
Standard
* The response frequencies for DC switching are average values measured on condition that the distance between each sensing object is twice as large as the sizeof the sensing object and the sensing distance set is half of the maximum sensing distance.
General
* Teflon is a registered trademark of Dupont Company and Mitsui Dupont Chemical Company for their fluoride resin.
Model E2EQ-X3D1E2EQ-X3D1-M1GJ
E2EQ-X7D1E2EQ-X7D1-M1GJ
E2EQ-X10D1E2EQ-X10D1-M1GJItem
Sensing distance 3 mm ±10% 7 mm ±10% 10 mm ±10%
Setting distance 0 to 2.4 mm 0 to 5.6 mm 0 to 8 mm
Differential distance 10% max.
Standard sensing object (mild steel)
12 x 12 x 1 mm 18 x 18 x 1 mm 30 x 30 x 1 mm
Response frequency 1 kHz 500 Hz 400 Hz
Control out-put
Switching capacity
3 to 100 mA
Residual voltage
3.0 V max. (under load current of 100 mA with cable length of 2 m)
Operating status (with sensing object approaching)
NO
Protective circuits Surge absorber, short-circuit protection
Ambient temperature Operating/Storage: -25°C to 70°C (with no icing or condensation)
Temperature influence ±10% max. of sensing distance at 23°C within temperature range of -25°C and 70°C
Voltage influence ±2.5% max. of Sensing distance within rated voltage range ±15%.
Shock resistance Destruction: 1,000 m/s2 for 10 times each in X, Y, and Z directions
Connection methodE2EQ-X#D1: Pre-wired models (Standard length: 2 m) E2EQ-X#D1-M1GJ type: Connector relay models (Standard length: 300 mm)
Weight (Packed state)
Pre-wired Approx. 120 g Approx. 160 g Approx. 220 g
Junction connector
Approx. 80 g Approx. 110 g Approx. 190 g
Model E2EQ-X4X1E2EQ-X4X1-M1JE2EQ-X3D1E2EQ-X3D1-M1GJ
E2EQ-X8X1E2EQ-X8X1-M1JE2EQ-X7D1E2EQ-X7D1-M1GJ
E2EQ-X15X1E2EQ-X15X1-M1JE2EQ-X10D1E2EQ-X10D1-M1GJItem
Sensing object Ferrous metal (Sensitivity lowers with non-ferrous metals)
Rated supply voltage (operat-ing voltage)
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
Leakage current 0.8 mA max.
Indicator lamp Operation indicator (red), operation setting indicator (green)
Ambient humidity Operating/Storage: 35% to 95%RH (with no condensation)
Insulation resistance 50 M min. (at 500 VDC) between energized parts and case
Dielectric strength 1,000 VAC for 1 min between energized parts and case
Vibration resistance 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions
Protective structure IEC60529 IP67
MaterialCase Teflon resin coating (base: brass) *
Sensing surface Teflon resin *
Accessories Instruction manual
E-59E2EQ
E2E
Q
Characteristic data (typical)
Sensing Distance vs. Sensing ObjectE2EQ-X4X1(-M1J) E2EQ-X8X1(-M1J) E2EQ-X15X1(-M1J)
E2EQ-X3D1(-M1GJ) E2EQ-X7D1(-M1GJ) E2EQ-X10D1(-M1GJ)
Side length of sensing object d (mm)
Sen
sing
dis
tanc
e X
(m
m) 5
4
3
2
1
0 5 10 15 20 25 30 35
Stainless steel (SUS304)
Mild steel
Brass
Copper
#dt=1mm
X
10
8
6
4
2
0 10 20 30 40 50
Sen
sing
dis
tanc
e X
(m
m)
Side length of sensing object d (mm)
Mild steel
Brass
Copper
Stainless steel (SUS304)
#dt=1mm
X
Side length of sensing object d (mm)
Sen
sing
dis
tanc
e X
(m
m) 20
16
12
8
4
0 10 3020 40 50 60 70 80
Stainless steel (SUS304)
Mild steel
BrassAluminum
Copper
#dt=1mm
X
4.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0 5 10 15 20 25Side length of sensing object d (mm)
30 35
Sen
sing
dis
tanc
e X
(m
m)
Aluminum
Stainless steel (SUS304)
Mild steel
Copper
Brass
#dt=1mm
X
10
9
8
7
6
5
4
3
2
1
0 45403530252015105
Sen
sing
dis
tanc
e X
(m
m)
Aluminum
Mild steel
Copper
Brass
Stainless steel (SUS304)
#dt=1mm
X
Side length of sensing object d (mm)
14
12
10
8
6
4
2
0 5 10 15 20 25 4530 40 50 5535
Sen
sing
dis
tanc
e X
(m
m)
Aluminum
Stainless steel (SUS304)
Mild steel
Copper
Brass
#dt=1mm
X
Side length of sensing object d (mm)
E-60 Proximity Sensors
Output Circuit Diagram
Long-distance type
Standard
Connecting Plug-in models
ModelOpe-rating status
Timing chart Output circuit
E2EQ-X4X1E2EQ-X8X1E2EQ-X15X1E2EQ-X4X1-M1JE2EQ-X8X1-M1JE2EQ-X15X1-M1J
NO
ModelOpe-rating status
Timing chart Output circuit
E2EQ-X3D1E2EQ-X7D1E2EQ-X10D1E2EQ-X3D1-M1GJE2EQ-X7D1-M1GJE2EQ-X10D1-M1GJ
NO
Model E2EQ-X#X1-M1J E2EQ-X#D1-M1GJ
Connection
Sensing object
(%) 100 80(TYP)
Rated sensing distance
Stable sensing zoneNon-sensing zoneUnstable sensing zone
Setting point
Lit
Not lit
Lit
Not lit
ON
OFF
Green indicator
Red indicator
Control output
0
Note:1. The load can be connected to either the +V or the 0-V line.2. Since there is no polarity, there is no need to pay attention to the brown or blue polarity.
Brown
Blue
Main circuit
+V
0V
Load
3
4
Wiring
Note:Terminals B and C are not used.
3
1
2 4
Sensing object
(%) 100 080(TYP)
Stable sensing zoneNon-sensing zoneUnstable sensing zone
Setting point
Main circuit
Lit
Not lit
Lit
Not lit
ON
OFF
Green indicator
Red indicator
Control output
Rated sensing distance
Wiring
Note:Terminals B and C are not used.
Note:The Load can be connected to either the +V or the 0-V line.
Load
Brown
Blue
Main circuit
+V
0V
1
4
A
DB
C
Main
circ
uit
1
2
3
4
1
2
3
4
Brown
Black (-)Blue (+)
Connector relay typeE2EQ-X#X1-M1J
Sensor I/O ConnectorsXS2F-D42#-#C0-A
not connected
Main
circ
uit 1
2
3
4
1
2
3
4
Brown (+)
Blue (-)
Connector relay typeE2EQ-X#D1-M1GJ
Sensor I/O ConnectorsXS2F-D42#-#A0-A
E-61E2EQ
E2E
Q
Precautions
Design
Effects of Surrounding Metal
Provide a minimum distance between the Sensor and the sur-
rounding metal as shown in the table below.
Effects of Surrounding Metal (Unit: mm)
Mutual Interference
If more than one Proximity Sensor is installed face to face or
in parallel, make sure that the distances between two Units
adjacent to each other are the same as or larger than the cor-
responding values shown in the following table.
Mutual Interference(Unit: mm)
Mounting
Do not tighten the nut with excessive force. A washer must be
used with the nut.
Note: 1 .The table below shows the tightening torques for part A and part Bnuts. In the previous examples, the nut is on the sensor head side(part B) and hence the tightening torque for part B applies. If this nutis in part A, the tightening torque for part A applies instead.
2 .The table below shows the value of tightening torques when usingtoothed washers.
Correct Use
Model Item l d D m n
E2EQ-X4X1(-M1J) 2.4 18 2.4 12 18
E2EQ-X8X1(-M1J) 3.6 27 3.6 24 27
E2EQ-X15X1(-M1J) 6 45 6 45 45
E2EQ-X3D11(-M1GJ)
0
12
0
8 18
E2EQ-X7D1(-M1GJ) 18 20 27
E2EQ-X10D1(-M1GJ) 30 40 45
Model Item A B
E2EQ-X4X1(-M1J) 30 20
E2EQ-X8X1(-M1J) 60 35
E2EQ-X15X1(-M1J) 110 90
E2EQ-X3D1(-M1GJ) 30 20
E2EQ-X7D1(-M1GJ) 50 35
E2EQ-X10D1(-M1GJ) 100 70
l
mn
mD
d dia.
l
AB
Torque Part A Part B
ModelLength (mm) Torque Torque
E2EQ-X4X1(-M1J)
---
30 Nm
E2EQ-X8X1(-M1J) 70 Nm
E2EQ-X15A(-M1J) 180 Nm
E2EQ-X3D1(-M1GJ) 2415 Nm ---
E2EQ-X7D1(-M1GJ) 29
E2EQ-X10D1(-M1GJ) 26 39 Nm 78 Nm
Part B Part A
Shielded Model
E-62 Proximity Sensors
Dimensions (Unit: mm)
Pre-wired Models
Long-distance type
Standard
E2EQ-X4X1
E2EQ-X8X1 E2EQ-X15X1
E2EQ-X3D1
E2EQ-X7D1 E2EQ-X10D1
CAD file E2EQ_03
21 dia.417
33102
938
M12 x 1Indicator *2
Two, clamping nuts Toothed washer
*1
*1: Vinyl-insulated round cable (flame-resistant), 4 dia.2/3 conductors (conducting cross-sectional area: 0.3 mm2/insulator diameter: 1.3 mmStandard length: 2mCable extension (through a single metal conduit): 200m max.*2: Operation indicator (red) and setting indicator (green).
CAD file E2EQ_01 CAD file E2EQ_05
*1: Vinyl-insulated round cable (flame-resistant), 6 dia.2/3 conductors (conducting cross-sectional area: 0.5 mm2/insulator diameter: 1.9 mmStandard length: 2mCable extension (through a single metal conduit): 200m max.*2: Operation indicator (red) and setting indicator (green).
29 dia.424
3810
2
1243
M18 x 1Indicator *2
Two, clamping nuts
Toothed washer
*1
*1: Vinyl-insulated round cable (flame-resistant), 6 dia.2/3 conductors (conducting cross-sectional area: 0.5 mm2/insulator diameter: 1.9 mmStandard length: 2mCable extension (through a single metal conduit): 200m max.*2: Operation indicator (red) and setting indicator (green).
42 dia.536
4310
3
1248
M30 x 1.5
Indicator *2
Two, clamping nuts
Toothed washer
*1
CAD file E2EQ_03
*1: Vinyl-insulated round cable (flame-resistant), 6 dia., 2 conductors (conducting cross-sectional area: 0.5 mm2/insulator diameter: 1.9 mmStandard length: 2mCable extension (through a single metal conduit): 200m max.*2: Operation indicator (red) and setting indicator (green).
5
4M12 x 1Two, toothed washer
Indicator *2*1Two, clamping nuts (Teflon coating)
17
21 dia.24
27.6
38
CAD file E2EQ_05 CAD file E2EQ_01
*1: Vinyl-insulated round cable (flame-resistant), 6 dia., 2 conductors (conducting cross-sectional area: 0.5 mm2/insulator diameter: 1.9 mmStandard length: 2mCable extension (through a single metal conduit): 200m max.*2: Operation indicator (red) and setting indicator (green).
2429 dia.
629
3247
4M18 x 1Two, toothed washer
Indicator *2 *1
Two, clamping nuts (Teflon coating)
*1: Vinyl-insulated round cable (flame-resistant), 6 dia., 2 conductors (conducting cross-sectional area: 0.5 mm2/insulator diameter: 1.9 mmStandard length: 2mCable extension (through a single metal conduit): 200m max.*2: Operation indicator (red) and setting indicator (green).
10
5M30 x 1.5Two, toothed washer
Indicator *2
*1
Two, clamping nuts (Teflon coating)
42 dia.
36 38
42
56
E-63E2EQ
E2E
Q
Plug-in Models
Long-distance type
Standard
Mounting Holes
E2EQ-X4X1-M1J
E2EQ-X8X1-M1J E2EQ-X15X1-M1J
E2EQ-X3D1-M1GJ
E2EQ-X7D1-M1GJ E2EQ-X10D1-M1GJ
CAD file E2EQ_07
21 dia.17 4
210
3338 9
Two, clamping nutsToothed washerM12 x 1
Indicator *2M12 x 1
*1
*1: Vinyl-insulated round cable (flame-resistant), 4 dia. (Conducting cross-sectional area: 0.3 mm2; insulator diameter: 1.3 mm)Standard length: 300 mm*2: Operation indicator (red) and setting indicator (green).
CAD file E2EQ_08 CAD file E2EQ_09
*1: Vinyl-insulated round cable (flame-resistant), 5 dia. (Conducting cross-sectional area: 0.5 mm2; insulator diameter: 1.9 mm)Standard length: 300 mm*2: Operation indicator (red) and setting indicator (green).
29 dia.24 4 10
3843 12
2
Indicator *2
Two, clamping nutsToothed washerM18 x 1 M12 x 1
*1
*1: Vinyl-insulated round cable (flame-resistant), 5 dia. (Conducting cross-sectional area: 0.5 mm2; insulator diameter: 1.9 mm)Standard length: 300 mm*2: Operation indicator (red) and setting indicator (green).
42 dia.
3105
4348 12
36
Indicator *2
Two, clamping nutsToothed washerM30 x 1.5
M12 x 1*1
CAD file E2EQ_04
*1: Vinyl-insulated round cable (flame-resistant), 6 dia.Standard length: 300 mm*2: Operation indicator (red) and setting indicator (green).
4M12 x 1
Two, toothed washer
Indicator *2 *1
Two, clamping nuts (Teflon coating)
21 dia.17 24
27.638
M12 x 1 (aluminum)
5
CAD file E2EQ_06 CAD file E2EQ_02
*1: Vinyl-insulated round cable (flame-resistant), 6 dia.Standard length: 300 mm*2: Operation indicator (red) and setting indicator (green).
6
29 dia.24 29
3247
Indicator *2*1
Two, toothed washerTwo, clamping nuts (Teflon coating)4M18 x 1
M12 x 1 (aluminum)
*1: Vinyl-insulated round cable (flame-resistant), 6 dia.Standard length: 300 mm*2: Operation indicator (red) and setting indicator (green).
42 dia.36
103842
56
Two, toothed washerTwo, clamping nuts (Teflon coating)5M30 x 1.5
*1
M12 x 1 (aluminum)
Indicator *2
F
Outer diameter M12 M18 M30
F (mm) 12.5 dia+0.5 18.5 dia.+0.5 30.5 dia.+0.5
E-64 Proximity Sensors
Inductive Proximity Sensor
E2FQSpatter-Resistant Sensor for Welding Application
* Teflon is a registered trademark of Dupont Company and Mitsui Du-pont Chemical Company for their fluoride resin.
Ordering Information
Characteristic data (typical)
Sensing Distance vs. Sensing Object
Shape Sensing distanceOutput
specificationsOperating
statusModel
M12DC 2-wire
NO
E2FQ-X2D1DC 3-wire NPN E2FQ-X2E1
M18
DC 2-wire E2FQ-X5D1DC 3-wire NPN E2FQ-X5E1
AC 2-wire Models E2FQ-X5Y1
M30
DC 2-wire E2FQ-X10D1DC 3-wire NPN E2FQ-X10E1
AC 2-wire Models E2FQ-X10Y1
E2FQ-X2# E2FQ-X5# E2FQ-X10#
Shielded
2mm
5mm
10mm
Side length of sensing object d (mm)
Sen
sing
dis
tanc
e X
(m
m)
0 5 10 15 20 25
2.4
2.2
2
1.8
1.6
1.4
1.2
1
0.8
0.6
0.4
0.2
Aluminum
Stainless steel (SUS304)
Mild steel
Brass
#dt=1mm
X
Side length of sensing object d (mm)
Sen
sing
dis
tanc
e X
(m
m)
0 5 10 15 20 25 30 35 40 50
7
6
5
4
3
2
1
Aluminum
Stainless steel (SUS304)
Mild steel
Brass
#dt=1mm
X
Side length of sensing object d (mm)
Sen
sing
dis
tanc
e X
(m
m)
0 10 20 30 40 50 60
12
11
10
9
8
7
6
5
4
3
2
1
Aluminum
Stainless steel (SUS304)
Mild steel
Brass
#dt=1mm
X
E-65E2FQ
E2F
Q
Rating/Performance
ModelItem
E2FQ-X2E1E2FQ-X2D1
E2FQ-X5E1E2FQ-X5D1, E2FQ-X5Y1
E2FQ-X10E1E2FQ-X10D1, E2FQ-X10Y1
Sensing distance 2 mm ±10% 5 mm ±10% 10 mm ±10%
Setting distance 0 to 1.6 mm 0 to 4 mm 0 to 8 mm
Differential distance E1, Y1 models: 10% max. of sensing distance
Sensing object Ferrous metal (Sensitivity lowers with non-ferrous metals)
Standard sensing object (mild steel)
12 x 12 x 1 mm 18 x 18 x 1 mm 30 x 30 x 1 mm
Response frequency*1
*1. The response frequencies for DC switching are average values measured on condition that the distance between each sensing object is twice as large as the sizeof the sensing object and the sensing distance set is half of the maximum sensing distance.
E1 models: 1.5 kHzD1 models: 800 Hz
E1 models: 600 Hz, D1 models: 500 Hz
E1 models: 400 Hz, D1 models: 300 Hz
Y1 models: 25 Hz
Power supply(Operating voltage range)
E1 models: 12 to 24 VDC, ripple (p-p) : 10% max., (10 to 30 VDC)D1 models: 12 to 24 VDC, ripple (p-p) : 20% max., (10 to 36 VDC)
Current consumption E1 models: 17 mA max.
Leakage current D1 models: 0.8 mA max., Y models: 5 to 300 mA
Control output
Switching capacity
E1 models: 200 mA max., D1 models: 5 to 100 mA DC, Y models: 5 to 300 mA
Residual voltage
E1 models: 2 V max. (load current: 200 mA with cable length: 2 m) Y models: Refer to the Specifications.D1 models: 4.0 V max. (under load current of 100 mA with cable length of 2 m)
Indicator lamp E,D models: detection indicator (red), Y models: operation indicator (red)
Operating status (with sensing object approaching)
E1 models, D1 models and Y1 models: NO
Protective circuits E1 models: Protection for reverse polarity, load short circuit, surge voltage
Ambient temperature Operating/Storage: -25°C to 70°C (with no icing or condensation)
Ambient humidity Operating/Storage: 35% to 95%RH (with no condensation)
Temperature influence 10% max. of sensing distance at 23°C within temperature range of -25°C to 70°C
Voltage influence E1 models: ±2.5% max. of sensing distance within rated voltage range ±15%
Insulation resistance 50 M min. (at 500 VDC) between energized parts and case
Dielectric strength E1, D1 models: 1,000 VAC 50/60 Hz for 1 min between energized parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistanceDestruction: 500 m/s2 for 10 times each in X, Y, and Z directions
Destruction: 1,000 m/s2 for 10 times each in X, Y, and Z directions
Protective structure IEC60529 IP67
Connection method Pre-wired models (standard length: 2 m)
Weight (Packed state) Approx. 70 g Approx. 130 g Approx. 170 g
MaterialCase
Teflon *2
*2. Teflon is a registered trademark of Dupont Company and Mitsui Dupont Chemical Company for their fluoride resin.
Sensing surface
Accessories Instruction manual
E-66 Proximity Sensors
Output Circuit Diagram
Precautions
Design
Effects of Surrounding Metal
Provide a minimum distance between the Sensor and the
surrounding metal as shown in the table below.
Effects of Surrounding Metal (Unit: mm)
Mutual Interference
If more than one Proximity Sensor is installed face to face or
in parallel, ensure that the distances between two Units adja-
cent to each other are the same as or larger than the corre-
sponding values shown in the following table.
Installation
Do not tighten the nut with excessive force. A washer must be
used with the nut.
Note: The table below shows the value of tightening torques when usingtoothed washers.
Others
Chemical resistance
Operating status
Output specifications Model Timing chart Output circuit
NO
NPNE2FQ-X2E1E2FQ-X5E1E2FQ-X10E1
DC 2-wireE2FQ-X2D1E2FQ-X5D1E2FQ-X10D1
AC 2-wire Models
E2FQ-X5Y1E2FQ-X10Y1
Correct Use
Yes
No
Operates
Releases
H
L
Load (between black and blue leads)Output voltage (between black and blue leads)
Sensing object
ON
OFF
Operation indicator
Brown
Black
Output
Blue
100W
4.7kW
2.2WMain circuit
+V
0V
(see note 2)
(see note 1)
Tr
Note:1. 200 mA max.(load current)2. When a transistor is connected
Load
Operation indicator
Operates
Releases
ON
OFF
Load
Sensing object
Yes
No
LoadBrown
Blue
Main circuit
+V
0V
Note:The load can be connected to either the +V or the 0-V line.
Operation indicator
Operates
Releases
ON
OFF
Load
Sensing object
Yes
No
LoadBrown
Blue
Main circuit
Model Item l d D m n
E2FQ-X2#
0
12
0
8 18
E2FQ-X5# 18 20 27
E2FQ-X10# 30 40 45
l
mn
l
mD
d dia.
ModelTorque Tensile strength
(torque)
E2FQ-X2# 0.98 Nm
E2FQ-X5#2 Nm
E2FQ-X10#
A
B
Mutual Interference (Unit: mm)
Model Item A B
E2FQ-X2# 30 20E2FQ-X5# 50 35E2FQ-X10# 100 70
E-67E2FQ
E2F
Q
Dimensions (Unit: mm)
Mounting Holes
E2FQ-X2E1 CAD file E2FQ_02
21 dia.
17
38
27
24
6M12 x 1
Two, Toothed washers
Two, clamping nut
Indicator(see note)
Note:Oil-resistant, vibration-resistant, and fire-retardant vinyl-insulated round cord, 6 dia. x 3 cores, standard length: 2 mThe cord can be extended in an independent conduit for 200 m maximum.
21 dia.
17
38
27
24
6M12 x 1
Two, Toothed washers
Two, clamping nut
Indicator(see note)
Note:Oil-resistant, vibration-resistant, and fire-retardant vinyl-insulated round cord, 6 dia. x 2 cores, standard length: 2 mThe cord can be extended in an independent conduit for 200 m maximum.
E2FQ-X2D1 CAD file E2FQ_02
29 dia.
40
47
32
2924
8M18 x 1
Two, Toothed washers
Two, clamping nut
Indicator
(see note)
Note:Oil-resistant, vibration-resistant, and fire-retardant vinyl-insulated round cord, 6 dia. x 3 cores, standard length: 2 mThe cord can be extended in an independent conduit for 200 m maximum.
CAD file E2FQ_03E2FQ-X5E1
29 dia.
40
47
32
2924
8M18 x 1
Two, Toothed washers
Two, clamping nut
Indicator
(see note)
Note:Oil-resistant, vibration-resistant, and fire-retardant vinyl-insulated round cord, 6 dia. x 2 cores, standard length: 2 mThe cord can be extended in an independent conduit for 200 m maximum.
E2FQ-X5D1E2FQ-X5Y1
CAD file E2FQ_03
42 dia.
36
57
50
41
38
8M30 x 1.5
Two, Toothed washers
Two, clamping nut
Indicator
(see note)
Note:Oil-resistant, vibration-resistant, and fire-retardant vinyl-insulated round cord, 6 dia. x 3 cores, standard length: 2 mThe cord can be extended in an independent conduit for 200 m maximum.
E2FQ-X10E1 CAD file E2FQ_01
42 dia.
36
57
50
41
38
8M30 x 1.5
Two, Toothed washers
Two, clamping nut
Indicator
(see note)
Note:Oil-resistant, vibration-resistant, and fire-retardant vinyl-insulated round cord, 6 dia. x 2 cores, standard length: 2 mThe cord can be extended in an independent conduit for 200 m maximum.
E2FQ-X10D1E2FQ-X10Y1
CAD file E2FQ_01
F
Model F (mm)
E2FQ-X2# 12.5 mm dia.
E2FQ-X5# 18.5 mm dia.
E2FQ-X10# 30.5 mm dia.
+0.50
+0.50
+0.50
E-68 Proximity Sensors
Compact Square Inductive Proximity Sensor
E2SWorld’s Smallest Square Sensor with Built-in Amplifier
Features
The 5.5 mm x 5.5 mm type permits smaller, space-saving ma-
chines and devices.
A 1 kHz response frequency is achieved matching increased
machine and device speed.
Full sealing structure housing, degree of protection IEC60529 IP67.
Long Sensing Distance: (E2S-#1, 1.6 mm) (E2S-#2, 2.5 mm)
Significantly lower current consumption. The 0.8 mA (for 24
VDC) leakage current for the DC 2-wire type has a ratio of ap-
proximately 1/20 compared to the conventional DC 3-wire
type. Optimum solution for multiple-sensor applications such
as cam switches.
5.5 mm
Adopted for more compact machines and devices.
5.5mm
1 kHz
IP67
1.5 times
TL-W1R5MC1
E2S-W2#
2.5mm
1.5mm
Permits stable detection of object flows.
1/20
World’s Smallest Sensor with Built-in Amplifier
High-Speed Response
Environment-Resistant Types
Long Sensing Distance (Com-pared to conventional models)
Low Current Consumption (Com-pared to conventional models)
E-69E2S
E2S
Ordering Information
SensorsDC 2-wire Models
* Models with different response frequency are available (NO only). These model numbers take the form E2S-###B (e.g., E2S-W11B)
DC 3-wire Models
* Models with different response frequency are available (NO only). These model numbers take the form E2S-###B (e.g., E2S-W11B)
Accessories (Order Separately)Mounting Brackets
Nomenclature
Shape Sensing surface Sensing distanceModel
Operating status
NO NCFront face E2S-W11 * E2S-W12
End face E2S-Q11 * E2S-Q12
Front face E2S-W21 * E2S-W22
End face E2S-Q21 * E2S-Q22
Shape Sensing surface Sensing distanceOutput
specifications
ModelOperating status
NO NCFront face
NPN
E2S-W13* E2S-W14
End face E2S-Q13* E2S-Q14
Front face E2S-W23* E2S-W24
End face E2S-Q23* E2S-Q24
Front face
PNP
E2S-W15* E2S-W16
End face E2S-Q15* E2S-Q16
Front face E2S-W25* E2S-W26
End face E2S-Q25* E2S-Q26
Shape Model Quantity Remarks
Y92E-C1R6
1
Provided with E2S-#1##
Y92E-C2R5 Provided with E2S-#2##
Y92E-D1R6 ---
Y92E-D2R5 ---
Unshielded 1.6mm
2.5mm
Unshielded
1.6mm
2.5mm
1.6mm
2.5mm
E2S - # # # #
A Compact square series
B Sensing direction W: Front face sensing Q: End face sensing
C Size and sensing distance (standard sensing object) 1: 5.5 x 5.5 mm, 1.6 mm (iron) 2: 8 x 8 mm, 2.5 mm (iron)
D Output 1: DC 2-wire NO 2: DC 2-wire NC 3: DC 3-wire NPN NO 4: DC 3-wire NPN NC 5: DC 3-wire PNP NO 6: DC 3-wire PNP NC
E Different response frequency No: Standard B: Different response frequency
A B C D E
E-70 Proximity Sensors
Rating/Performance
DC 2-wire Models
* The response frequencies for DC switching are average values measured under the condition that the distance between each sensing object is twice as large as thesize of the sensing object and the sensing distance set is half of the maximum sensing distance.
DC 3-wire Models
* The response frequencies for DC switching are average values measured under the condition that the distance between each sensing object is twice as large as thesize of the sensing object and the sensing distance set is half of the maximum sensing distance.
Model E2S-W11E2S-W12
E2S-Q11E2S-Q12
E2S-W21E2S-W22
E2S-Q21E2S-Q22Item
Sensing surface Front face End face Front face End face
Sensing distance 1.6 mm ±10% 2.5 mm ±15%
Setting distance 0 to 1.2 mm 0 to 1.9 mm
Differential distance 10% max.
Sensing object Ferrous metal (Sensitivity lowers with non-ferrous metals)
Standard sensing object
Iron, 12 x 12 x 1 mm Iron, 15 x 15 x 1 mm
Response frequency 1 kHz min.
Rated supply voltage (operating voltage)
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
Leakage current 0.8 mA max.
Control output
Switching capacity
3 to 50 mA DC max.
Residual voltage
3 V max. (under load current of 50 mA with cable length of 1 m)
Indicator lamp##1 models: Operation indicator(red LED), Operation set indicator(green LED) ##2 models: Operation indicator(red LED)
Operating status (with sensing object approaching)
##1 models: NO##2 models: NC
Model E2S-W13E2S-W14
E2S-Q13E2S-Q14
E2S-W23E2S-W24
E2S-Q23E2S-Q24
E2S-W15E2S-W16
E2S-Q15E2S-Q16
E2S-W25E2S-W26
E2S-Q25E2S-Q26Item
Sensing surface Front face End face Front face End face Front face End face Front face End face
Sensing distance 1.6 mm ±10% 2.5 mm ±15% 1.6 mm ±10% 2.5 mm ±15%
Setting distance 0 to 1.2 mm 0 to 1.9 mm 0 to 1.2 mm 0 to 1.9 mm
Differential distance 10% max.
Sensing object Ferrous metal
Standard sensing object
Iron, 12 x 12 x 1 mm Iron, 15 x 15 x 1 mm Iron, 12 x 12 x 1 mm Iron, 15 x 15 x 1 mm
Response frequency 1 kHz min.
Rated supply voltage (operating voltage)
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
Current consumption 13 mA max. (24 VDC, unload)
Control output
Switching capacity
NPN open collector 100 mA max. (30 VDC max.) PNP open collector 50 mA max. (30 VDC max.)
Residual voltage
1 V max. (under load current of 50 mA with cable length of 1 m)
Indicator lamp Operation indicator (orange)
Operating status (with sensing object approaching)
##3 models: NO##4 models: NC
##5 models: NO##6 models: NC
E-71E2S
E2S
Specifications
Characteristic data (typical)
Item Model E2S-###Protective circuits Reverse polarity connection and surge absorberAmbient temperature Operating: -25°C to 70°C, Storage: -40°C to 85°C (with no icing or condensation)Ambient humidity Operating: 35% to 90%RH, Storage: 35% to 95%RH (with no condensation)Temperature influence ±15% max. of sensing distance at 23°C in temperature range of -25°C to 70°CVoltage influence ±2.5% max. of sensing distance within a range of ±10% of rated supply voltageInsulation resistance 50 M min. (at 500 VDC) between energized parts and caseDielectric strength 1,000 VAC for 1 min between energized parts and caseVibration resistance 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directionsShock resistance Destruction: 500 m/s2 for 3 times each in X, Y, and Z directionsProtective structure IEC60529 IP67Connection method Pre-wired models (Standard length: 3 m)Weight (Packed state) Approx. 10 gMaterial Case PolyarylateAccessories Mounting Brackets
Sensing Distance vs. Sensing Object
E2S-W1#/-Q1# E2S-W2#/-Q2#
Side length of sensing object d (mm)
Dis
tanc
e X
(m
m)
0 10 20 30 40 50
2
1.5
1
0.5
SUS
Copper
Iron
Aluminum
Brass
X
#dt=1mm
#dt=1mm
X
Side length of sensing object d (mm)
Dis
tanc
e X
(m
m)
0 10 20 30 40 50 60
4
3
2
1
SUS
Copper
Iron
Aluminum
Brass
X
E-72 Proximity Sensors
Output Circuit Diagram
DC 2-wire Models
DC 3-wire Models
Operating status
Model Timing chart Output circuit
NO
E2S-W11E2S-W21E2S-Q11E2S-Q21
NC
E2S-W12E2S-W22E2S-Q12E2S-Q22
Operating status
Output specifications Model Timing chart Output circuit
NO
NPN
E2S-W13E2S-W23E2S-Q13E2S-Q23
NC
E2S-W14E2S-W24E2S-Q14E2S-Q24
NO
PNP
E2S-W15E2S-W25E2S-Q15E2S-Q25
NC
E2S-W16E2S-W26E2S-Q16E2S-Q26
Sensing object
Rated sensing distance
(%) 100 080
Stable sensing zoneNon-sensing zone
Unstable Sensing zone
Setting position
Proximity Sensor
ON
OFF
ON
OFF
ON
OFF
Setting indicator (green)
Operation indicator (red)
Control output
LoadBrown
Blue
Main circuit
+V
0V
100 0
Sensing object
(%)
Sensing zoneNon-sensing zone
Non-sensing zone
Proximity Sensor
ON
OFF
ON
OFF
Operation indicator (red)
Control output
Yes
No
ON
OFF
ON
OFF
Sensing object
Operation indicator (orange)
Output transistor (load)
Load
Brown
Black
Output
Blue
Main circuit
+V
0V
* Maximum load current: 50 mA
*
Output transistor (load)
Yes
No
ON
OFF
ON
OFF
Sensing object
Operation indicator (orange)
Yes
No
ON
OFF
ON
OFF
Output transistor (load)
Sensing object
Operation indicator (orange)
Load
Brown
Black
Blue
Main circuit
+V
0V
* Maximum load current: 50 mA
*
Output transistor (load)
Yes
No
ON
OFF
ON
OFF
Sensing object
Operation indicator (orange)
E-73E2S
E2S
Precautions
Design
Effects of Surrounding Metal
Provide a minimum distance between the Sensor and the sur-
rounding metal as shown in the table below.
Front Surface Sensing Type (Not exceeding the sensor head
height)
(Unit: mm)
End Surface Sensing Type
(Unit: mm)
Mutual Interference
If more than one Sensor is located face to face or in parallel,
be sure to maintain enough space between adjacent Sensors
to suppress mutual interference as provided in the following
diagram,.
(Unit: mm)
Note: The above values in parentheses are applicable when using two sensorswith different frequencies.
Mounting
Tightening torgues
Do not tighten the E2S-W(Q)2#mounting screws to a torque
exceeding 0.7 Nm.
Correct Use
Model Length A B C
E2S-W1#0
8 2
E2S-W2# 15 10
Model Length A B C
E2S-Q1# 8 3 2
E2S-Q2# 15 10 3
Sensing surface
Proximity Sensor
ASensing surface
Proximity Sensor
C CB
A B
B
C
Model Length A B
E2S-W(Q)1# 50 (40) 20 (5.5)
E2S-W1# 75 (50) 25 (8)
Front Surface Sensing
TypeB
A
End Surface Sensing Type
A B
E-74 Proximity Sensors
Dimensions (Unit: mm)
Sensors
Accessories (Order Separately*)
E2S-W1#CAD file E2S_03
If mounting bracket is attached
Indicator *
* E2S-W11#
E2S-W12# E2S-W13# E2S-W14# E2S-W15# E2S-W16#
Operation indicator (orange)
Operation indicator (red)Setting indicator (green)
Operation indicator (red)
2.9 dia. vinyl-insulated round cable, 2 / 3 cores (conductor sectional area: 0.14mm2, Insulator diameter: 0.9 dia.) ; standard length: 1 m
2.6
5.9
2.3
2
6.45.55.98.4
Sensing surface
191
22
22.325.1
R1.5
E2S-Q1# CAD file E2S_04
If mounting bracket is attached
5.9
6.4
191
2
22.325.1
2
R1.52.9 dia. vinyl-insulated round cable, 2 / 3 cores (conductor sectional area: 0.14mm2, Insulator diameter: 0.9 dia.) ; standard length: 1 m
Sensing surface
Indicator *
5.55.98.4 2.3
2
* E2S-Q11# E2S-Q12# E2S-Q13# E2S-Q14# E2S-Q15# E2S-Q16#
Operation indicator (red)
Operation indicator (red)Setting indicator (green)
Operation indicator (red)
E2S-W2#
*E2S-W21#
E2S-W22#
E2S-W23# E2S-W24# E2S-W25# E2S-W26#
Operation indicator (orange)
Operation indicator (red)Setting indicator (green)
Operation indicator (red)
8
7.45.3
11.5
15.5
3.1 dia. mounting holes
10.18
Sensing surfaceIndicator *
2.9 dia. vinyl-insulated round cable, 2 / 3 cores (conductor sectional area: 0.14mm2, Insulator diameter: 0.9 dia.) ; standard length: 1 m
7.47.8
2.3
11.3
203
10.82.5
22
3.1 dia.
CAD file E2S_02
If mounting bracket is attached
E2S-Q2#
If mounting bracket is attached
CAD file E2S_01
88.4
8 2.38.9
14.53.64.1
18.511.3
233
Sensing surface
Indicator *2.9 dia. vinyl-insulated round cable, 2 / 3 cores (conductor sectional area: 0.14m‡u, Insulator diameter: 0.9 dia.) ; standard length: 1 m
10.8
3.1 dia.
2.5
2.5
5.322
3.1 dia. mounting holes *E2S-Q21#
E2S-Q22#
E2S-Q23# E2S-Q24# E2S-Q25# E2S-Q26#
Operation indicator (orange)
Operation indicator (red)Setting indicator (green)
Operation indicator (red)
Mounting BracketsY92E-C1R6
Mounting Holes
R1.5
2.5 2 1.5
145.3
2
1517.2
20.4
5.98.4
2.4
R1.2
5.66.4
1.11.3 3.5
9.51.52.3
5.7 2
2.3
0.4
Two, R0.7
Two, R1.2
3
17.5
2.4 dia. screw depth 2 min.
M3
11.38
Material: Stainlesssteel (SUS304)
* Provided with E2S-#1## Mounting Holes
11.5
dia. 2.4 screw depth 3 min.
M3 screw depth 8 min.
10.82.5 2.5 0.4
8.1 2.3
0.411.3
22
3.1 dia.
Mounting BracketsY92E-C2R5
Material: Stainlesssteel (SUS304)
* Provided with E2S-#2#
Four, R13.2
17.4
5
5.6
5.3
3.27 5
3 3
1
Two, R1.6
R1.6
12
Two, M3Mounting Holes
0.3
0.9
Mounting BracketsY92E-D1R6
Material: Stainlesssteel (SUS304)
22.4
3.2
1
7
8
7.8
16
Two, R1.6 Four, R1
3.2
5
17
Two, M3Mounting Holes
0.2
R1.6
Mounting BracketsY92E-D2R5
Material: Stainlesssteel (SUS304)
MEMO
E-75E2S
E2S
E-76 Proximity Sensors
Flat size Proximity Sensors
TL-WSpace-Saving Flat ProximitySensor
Ordering Information
DC 2-wire Models
DC 3-wire Models
*1. Models with different response frequency are available. These model numbers take the form TL-W5MD#5 (e.g., TL-W5MD15)
Shape Sensing distanceModel
Output and operating statusNO NC
TL-W5MD1 TL-W5MD2
Shape Sensing distanceOutput
specifications
ModelOutput and operating status
PNP-NO PNP-NC NPN-NO NPN-NC
DC 3-wire
TL-W1R5MB1 --- TL-W1R5MC1 ---
TL-W3MB1 TL-W3MB2 TL-W3MC1 TL-W3MC2
TL-W5MB1 TL-W5MB2 TL-W5MC1 TL-W5MC2
--- --- TL-W20ME1 TL-W20ME2
DC 3-wire TL-W5F1 TL-W5F2 TL-W5E1 TL-W5E2
5mm *1 *1
1.5mm*1
3mm*1
5mm*1
20mm *1 *1
Shielded5mm
E-77TL-W
TL
-W
Rating/Performance
DC 2-wire Models
* The response frequencies for DC switching are average values measured under the condition that the distance between each sensing object is twice as large as thesize of the sensing object and the sensing distance set is half of the maximum sensing distance.
Item Model TL-W5MD#
Sensing distance 5 mm ±10%
Setting distance 0 to 4 mm
Differential distance 10% max.
Sensing object Ferrous metal(Sensitivity decreases with non-ferrous metals)
Standard sensing object Iron, 18 x 18 x 1 mm
Response frequency 0.5 kHz
Rated supply voltage (operating voltage)
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
Leakage current 0.8 mA max.
Control output
Switching capacity 3 to 100 mA
Residual voltage 3.3 V max. (under load current of 100 mA with cable length of 2 m)
Indicator lampD1 models: Operation indicator (Red LED), Operation set indicator (Green LED) D2 models: Operation indicator (Red LED)
Operating status (with sensing object approaching)
D1 models: NO D2 models: NC
Protective circuits Surge absorber, short-circuit protection
Ambient temperature Operating/Storage: -25°C to 70°C (with no icing or condensation)
Ambient humidity Operating/Storage: 35% to 95%RH (with no condensation)
Temperature influence ±10% max. of sensing distance at 23°C within a temperature range of -25°C and 70°C
Voltage influence ±2.5% max. of Sensing distance within a rated voltage range ±15%.
Insulation resistance 50 M min. (at 500 VDC) between energized parts and case
Dielectric strength 1,000 VAC for 1 min between energized parts and case
Vibration resistance 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 500 m/s2 for 3 times each in X, Y, and Z directions
Protective structure IEC60529 IP67
Connection method Pre-wired models (standard length: 2 m)
Weight (Packed state) Approx. 45 g
Material
Case
Heat-resistant ABS resinSensing surface
Accessories Instruction manual
E-78 Proximity Sensors
DC 3-wire Models
ModelItem
TL-W1R5M#1 TL-W3M## TL-W5M## TL-W5E#/F# TL-W20ME#
Sensing distance 1.5 mm ±10% 3 mm ±10% 5 mm ±10% 20 mm ±10%
Setting distance 0 to 1.2 mm 0 to 2.4 mm 0 to 4 mm 0 to 16 mm
Differential distance 10% max.1% to 15% of sensing distance
Sensing object Ferrous metal (refer to Engineering Data for non-ferrous metal on page E-55)
Standard sensing object
Iron, 8 x 8 x 1 mmIron, 12 x 12 x 1 mm
Iron, 18 x 18 x 1 mmIron, 50 x 50 x 1 mm
Response frequency 1 kHz min. 600 Hz min. 500 Hz min. 300 Hz min. 40 Hz min.
Power supply (Operating voltage range)
12 to 24 VDC (10 to 30 VDC) ripple (p-p): 10% max.10 to 30 VDC with a ripple (p-p) of 20% max.
12 to 24 VDC (10 to 30 VDC) ripple (p-p): 10% max.
Current consumption 15 mA max. at 24 VDC (no-load) 10 mA max. 15mA max. at 24 VDC (no-load)8 mA at 12 VDC, 15 mA at 24 VDC
Control output
Switching capacity
NPN open collector 100 mA max. (30 VDC max.)
NPN open col-lector 12 VDC 50 mA max. (30 VDC max.)24 VDC 100 mA max. (30 VDC max.)
200 mA
12 VDC 100mA max., 24 VDC 200 mA max.
Residual voltage
1 V max. (under load current of 100 mA with cable length of 2 m)
1 V max. (under load current of 50 mA with cable length of 2 m)
2 V max. (under load current of 200 mA with cable length of 2 m)
1 V max. (under load current of 200 mA with ca-ble length of 2 m)
Indicator lamp Detection indicator (red LED)
Operating status (with sensing object approaching)
NOC1 models: NOC2 type: NC
E1 models, F1 models: NOE2 models, F2 models: NC
Protective circuits Reverse connection protection, surge absorber
Ambient temperature Operating/Storage: -25°C to 70°^C (with no icing or condensation)
Ambient humidity Operating/Storage: 35% to 95%RH (with no condensation)
Temperature influ-ence
±10% max. of sensing distance at 23°C within the temperature range of -25°C and 70°C
Voltage influence±2.5% max. of sensing distance within a range of ±10% of rated power supply voltage
±2.5% max. of sensing dis-tance within a range of ±20% of rated power supply voltage
±2.5% max. of sensing distance within a range of ±10% of rated power supply voltage
Insulation resistance 50 M min. (at 500 VDC) between energized parts and case
Dielectric strength 1000 VAC 50/60 Hz for 1 min between energized part and case
Vibration resistance 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 500 m/s2 for 3 times each in X, Y, and Z directionsDestruction: 500 m/s2 for 10 times each in X, Y, and Z directions
Protective structure IEC60529 IP67
Connection method Pre-wired models (standard length: 2 m)
Weight (Packed state)
30 g Approx. 45 g Approx. 70 g Approx. 180 g
Material
Case Heat-resistant ABS resin Diecast aluminumHeat-resistant ABS resin
Sensing surface
Heat-resistant ABS resin
AccessoriesMounting bracket, instruction manual
Instruction manual
E-79TL-W
TL
-W
Characteristic data (typical)
Sensing Distance vs. Sensing Object
TL-W1R5M# TL-W3M# TL-W5MB#/C#
TL-W5E#/-W5F#/-W5MD# TL-W20#
4
3
2
1
0 10 20 30 40 50 60
Sen
sing
dis
tanc
e X
(m
m)
Side length of sensing object d (mm)
Brass
Aluminum
Iron
Copper
Stainless steel (SUS304)
#d t=1mmX
4
3
2
1
0 10 20 30 40 50 60
Sen
sing
dis
tanc
e X
(m
m)
Side length of sensing object d (mm)
Brass
Aluminum
Iron
Copper
Stainless steel (SUS304)
7
6
5
4
3
2
1
0 10 20 30 40 50 60
BrassAluminum
Iron
Copper
Stainless steel (SUS304)
Sen
sing
dis
tanc
e X
(m
m)
Side length of sensing object d (mm)
#d t=1mmX
6
5
4
3
2
1
0 5 10 15 20 25 30 35 40 45
Sen
sing
dis
tanc
e X
(m
m)
Side length of sensing object d (mm)
Brass
Aluminum
Iron
Stainless steel (SUS304)
#d t=1mmX
24
22
20
18
16
14
12
10
8
6
4
2
0 10 20 30 40 50 60 70 80 90
Sen
sing
dis
tanc
e X
(m
m)
Side length of sensing object d (mm)
Brass
Aluminum
Iron
Stainless steel (SUS304)
#d t=1mmX
E-80 Proximity Sensors
Output Circuit Diagram
DC 2-wire Models
DC 3-wire Models
Operating status Model Timing chart Output circuit
NO TL-W5MD1
NC TL-W5MD2
Operating status
Model Timing chart Output circuit
NOTL-W1R5M#1TL-W3M#1TL-W5M#1
NC TL-W3M#2TL-W5MC2
NOTL-W1R5B1TL-W3MB1TL-W5MB1
NC TL-W3MB2TL-W5MB2
NO TL-W5E1TL-W20ME1
NC TL-W5E2TL-W20ME2
Sensing object
(%) 100 080(TYP)
Stable sensingzone
Non-sensingzone
UnstableSensing zone
Setting position
Proximity Sensor
ON
OFF
ON
OFF
ON
OFF
Setting indicator (green)
Operation indicator (red)
Control output
Rated sensing distance
LoadBrown
Blue
Maincircuit
+V
0V
Note: The Load can be connected to either the +V and 0-V side.
Proximity SensorSensing zoneNon-sensing zone
Sensingobject
(%) 0
ON
OFF
ON
OFF
Operation indicator (red)
Rated sensing distance100
Control output
Sensing objectYesNo
Output transistor (load)
ONOFF
Operation indicator(red)
ONOFF *
* Maximum load current: 100 mA
Output
Load
Brown
Black
Blue
100W
Maincircuit
+V
0V
Sensing objectYesNo
Output transistor (load)
ONOFF
Operation indicator(red)
ONOFF
Sensing objectYesNo
Output transistor (load)
ONOFF
Operation indicator(red)
ONOFF
Load
Brown
Black
Blue100W
Maincircuit
+V
0V
Sensing objectYesNo
Output transistor (load)
ONOFF
Operation indicator(red)
ONOFF
Sensing objectYesNo
OperateRelease
Load(between brown and black)
Output voltage(between blue and black)
HL
Operation indicator (red)ON
OFF
Load
Brown+V
Tr
Black
*2
*1
* Maximum load current: 100 mA* 2. Current flows in this directionif the circuit incorporates the transistor.
2.2W
4.7kW
100W
Blue0V
Output
Maincircuit
Sensing objectYesNo
OperateRelease
Load(between brown and black)
Output voltage(between blue and black)
HL
Operation indicator (red)ON
OFF
E-81TL-W
TL
-W
Precautions
Design
Effects of Surrounding Metal
Provide a minimum distance between the Sensor and the sur-
rounding metal as shown in the table below.
Front Surface Sensing Type (Not exceeding the sensor head
height).
Effects of Surrounding Metal(Unit: mm)
Mutual Interference
If two or more Sensors are mounted face to face or side by side,
keep them separate at the following minimum distance.
Mutual Interference (unit: mm)
Note: The above values in parentheses are applicable when using two sensorswith different frequencies.
Installation
Use M3 flat-head screws to install TL-W1R5M# and
TL-W3M#.
Ensure that the resin cover should be tightened with
a torque according to the following table.
Adjustment
Power ON
Please note that the power injection AND connection gener-
ate an error pulse for approximately 1 ms.
NO TL-W5F1
NC TL-W5F2
Operating status
Model Timing chart Output circuit
Sensing objectYesNo
OperateRelease
Load(between brown and black)
Output voltage(between blue and black)
HL
Operation indicator (red)ON
OFF
Brown+V
Tr
Black*2
*12.2W
4.7kWBlue
0V
Output
Maincircuit
100WLoad
* 1. Maximum load current: 200 mA* 2. Current flows in this directionif the circuit incorporates the transistor.
Sensing objectYesNo
OperateRelease
Load(between brown and black)
Output voltage(between blue and black)
HL
Operation indicator (red)ON
OFF
Correct Use
Model Length l m n
TL-W1R5M# 2
0
8
TL-W3M# 3 12
TL-W5MD#5 20
TL-W5M#
TL-W20ME# 25 16 100
TL-W5E#/-W5F# 0 0 20
Sensing surface
Proximity Sensor
mSensing surface
Proximity Sensor
l lB
Model Length A B
TL-W1R5M# 75 (50) 120(60)
TL-W3MC# 90 (60) 200(100)
TL-W5MD#120(80) 60(30)
TL-W5MC#
TL-W20ME# 200(100) 200(100)
TL-W5E#/-W5F# 50 35
Model Tensile strength (torque)
TL-W1R5MC1
0.98 NmTL-W3MC#
TL-W5MD#
TL-W20M# 1.5 Nm
A B
E-82 Proximity Sensors
Dimensions (Unit: mm)
TL-W1R5M#1 CAD file TL_18
25
8 9
90˚
8
5.5
3
Mounting hole forM3 pan-head screw
16±0.2
5±0.2
* Vinyl-insulated round cable with three conductors, 2.9 dia.(conductor cross-sectional area: 0.15 mm²; insulation diameter: 0.9 mm); standard length: 2 m
6 dia.
3.2 dia.Indicator
Indicator
Operation indicator (red)
Sensing surface*
22.4
16
3.2
7.8
R1.6R1.6
8
5
1 3.2
7
(See note)
Note: Mounting dimensions: 17±0.2
Mounting Bracket (Attachment)
TL-W3M## CAD file TL_20
27
8 9
10
6
3
Mounting hole for M3 pan-head screw
17±0.2
5±0.2
90˚
6 dia.
3.2 dia. Indicator
* Vinyl-insulated round cable with three conductors,2.9 dia. (conductor cross-sectional area: 0.14 mm2; insulation diameter: 0.9 mm); standard length: 2 m
Indicator
Operation indicator (red)
Sensing surface(See note)
22.4
16
3.2
7.8
R1.6R1.6
10
5.5
1 3.2
9
(See note)
Note: Mounting dimensions: 17±0.2
Mounting Bracket (Attachment)
TL-W5M##
30.5
12.5
18
8.5
4.5
418
10 87.56.5
5
3.5
* 1. TL-W5MC1: Vinyl-insulated round cable with three conductors, 4 dia. (conductor cross-sectional area:0.2 mm2; insulation diameter: 1.2 mm); standard length: 2 mTL-W5MD# : Vinyl-insulated round cable with two conductors, 4 dia. (conductor cross-sectional area: 0.3 mm²; insulation diameter: 1.3 mm); standard length: 2 m
* 2. C type: Operation indicator (red)D type: Operation indicator (red), Setting indicator (green)
12±0.1
Indicator * 2
Sensing surface
*1
CAD file TL_22 TL-W5E#TL-W5F#
CAD file TL_21
4
50 (2)
8
4.5
10.5
10
15
10
3
16 dia.Sensing surface
*
24.9
Operation indicator (red)
4.2 dia.
7.2 dia.* Vinyl-insulated round cable with three conductors,4 dia. (conductor cross-sectional area: 0.2mm2; insulation diameter: 1.2 mm); standard length: 2 m
0-0.4
15±0.2
Two, 4.5 dia.
Mounting Holes
TL-W20ME#
53 1.5
6 20
18
18 1
5
5
23
Sensing surface
Operation indicator (red)
40 30±0.1
27±0.1
Two, 5.5 dia. mounting holes
Vinyl-insulated round cable with three conductors,6 dia. (conductor cross-sectional area: 0.5 mm2; insulation diameter: 1.9 mm); standard length: 2 m
CAD file TL_19
MEMO
E-83TL-W
TL
-W
E-84 Proximity Sensors
Square Size Proximity Sensors
TL-NA Variety of Models Avail-able for a Wide Range of Ap-plications
Ordering Information
SensorsDC 2-wire
Note: Models with different response frequency are available. These model numbers take the form TL-N#MD#5 (e.g., TL-N5ME15)
DC 3-wire and AC 2-wire Models
Note: Models with different response frequency are available. These model numbers take the form TL-##M##5 (e.g., TL-N5ME15)*1. Each of these models has a cord with a standard length of 5 m.*2. Each of these models with a robot cord is available and classified with the suffix "R" added to the model number (e.g., TL-N5ME1-R).
Shape Sensing distanceModel
Operating statusNO NC
#25 TL-N7MD1 TL-N7MD2
#30 TL-N12MD1 TL-N12MD2
#40 TL-N20MD1 TL-N20MD2
Shape Sensing distance Output specificationsModel
Operating statusNO NC
#25DC 3-wire NPN TL-N5ME1 TL-N5ME2
AC 2-wire Models TL-N5MY1 TL-N5MY2
#30DC 3-wire NPN TL-N10ME1 TL-N10ME2
AC 2-wire Models TL-N10MY1 TL-N10MY2
#40DC 3-wire NPN TL-N20ME1 TL-N20ME2
AC 2-wire Models TL-N20MY1 TL-N20MY2
Unshielded7mm
12mm
20mm
Unshielded
5mm
*1*2
*1*2
10mm
*1*2
*1*2
20mm
*1*2 *2
E-85TL-N
TL
-N
Accessories (Order Separately)Mounting Brackets
Rating/PerformanceDC 2-wire
* The response frequencies for DC switching are average values measured under the condition that the distance between each sensing object is twice as large as thesize of the sensing object and the sensing distance set is half of the maximum sensing distance.
Item ModelApplicable models
The Mounting Bracket is provided with this models.
Order separately
Mounting Brackets
Y92E-C5 TL-N5ME#, TL-N7MD# TL-N5MY#
Y92E-C10 TL-N10ME#, TL-N12MD# TL-N10MY#
Y92E-C20 TL-N20ME#, TL-N20MD# TL-N20MY#
Mounting Bracket for Conduit
Y92E-N5C15 --- TL-N5ME#, TL-N5MY#
Y92E-N10C15 --- TL-N10ME#, TL-N10MY#
Item Model TL-N7MD# TL-N12MD# TL-N20MD#
Sensing distance 7 mm ±10% 12 mm ±10% 20 mm ±10%
Setting distance 0 to 5.6 mm 0 to 9.6 mm 0 to 16 mm
Differential distance 10% max.
Sensing object Ferrous metal(Sensitivity decreases with non-ferrous metals)
Standard sensing object
Iron, 30 x 30 x 1 mm iron, 40 x 40 x 1 mm iron, 50 x 50 x 1 mm
Response frequency 0.5 kHz 0.3 kHz
Power supply (Operating voltage range)
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
Leakage current 0.8 mA max.
Con
trol
out
put Switching
capacity3 to 100 mA
Residual voltage
3.3 V max. (Load current 100 mA, Cable length: 2 m)
Indicator lampD1 models: Operation indicator (red LED), Operation set indicator (green LED) D2 models: Operation indicator (red LED)
Operating status (with sensing ob-ject approaching)
D1 models: NO D2 models: NC
Protective circuits Surge absorber, short-circuit protection
Ambient temperature Operating/Storage: -25°C to 70°C (with no icing or condensation)
Ambient humidity Operating/Storage: 35% to 95%RH
Temperature influence ±10% max. sensing distance at 23°C within the temperature range of -25°C and 70°C
Voltage influence ±2.5% max. sensing distance within rated voltage range ±15%.
Insulation resistance
50 M min. (at 500 VDC) between energized parts and case
Dielectric strength 1,000 VAC for 1 min between energized parts and case
Vibration resistance 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 1,000 m/s2 for 10 times each in X, Y, and Z directions
Protective structure IEC60529 IP67
Connection method Pre-wired models (standard length: 2 m)
Weight (Packed state)
Approx. 145 g Approx. 170 g Approx. 240 g
Ma-terial
Case
Heat-resistant ABS resinSensing surface
Accessories Mounting bracket, instruction manual
E-86 Proximity Sensors
DC 3-wire and AC 2-wire Models
Item Model TL-N5ME#, TL-N5MY# TL-N10ME#, TL-N10MY# TL-N20ME#, TL-N20MY#
Sensing distance 5 mm ±10% 10 mm ±10% 20 mm ±10%
Setting distance 0 to 4 mm 0 to 8 mm 0 to 16 mm
Differential dis-tance
15% max. of sensing distance
Sensing object Ferrous metal (Sensitivity decreases with non-ferrous metals)
Standard sensing object (mild steel)
30 x 30 x 1 mm 40 x 40 x 1 mm 50 x 50 x 1 mm
Response frequency*1
*1. The response frequencies for DC switching are average values measured under the condition that the distance between each sensing object is twice as large asthe size of the sensing object and the sensing distance set is half of the maximum sensing distance.
E models: 500HzY models: 10 Hz
E models: 40HzY models: 10 Hz
Supply voltage*2 (operating volt-age range)
*2. The E models (DC switching type) can be used with a full-wave rectification power of 24 VDC ±10%.
E models: 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.Y models: 100 to 220 VAC (90 to 250 VAC) 50/60 Hz
Current consumption
E models: 8 mA max. at 12 VDC, 15 mA max. at 24 VDC
Leakage current Y models: Refer to the Specifications
Con
trol
out
put Switching
capacityE models: 100 mA max. at 12VDC, and 200 mA max. at 24 VDCY models: 10 to 200 mA
Residual voltage
E models: 1 V max. with a current of 200 mA
Indicator lampE models: Detection indicator (red LED)Y models: Operation Indicator (red LED)
Operating status (with sensing ob-ject approaching)
E1, Y1 models: NO E2, Y2 models: NC
Protective circuits
E models: Reverse connection protection and surge absorberY models: Surge absorber
Ambient temperature
Operating/Storage: -25°C to 70°C (with no icing or condensation)
Ambient humidity Operating/Storage: 35% to 95%RH (with no condensation)
Temperature influence
±10% max. sensing distance at 23°C within a temperature range of -25°C and 70°C
Voltage influenceE models: ±2.5% max. sensing distance within a range of ±10% of rated supply voltage Y models: ±1% max. sensing distance within a range of ±10% of rated supply voltage
Insulation resistance
50 M min. (at 500 VDC) between energized parts and case
Dielectric strengthE models: 1,000 VAC, 50/60 Hz for 1 min between energized parts and caseY models: 2,000 VAC, 50/60 Hz for 1 min between energized parts and case
Vibration resistance
10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 500 m/s2 for 10 times each in X, Y, and Z directions
Protective structure
IEC60529 IP67
Connection method
Pre-wired models (standard length: 2 m)
Weight (Packed state)
Approx. 145 g Approx. 170 g Approx. 240 g
Ma-terial
Case
Heat-resistant ABS resinSensing surface
Accessories E models: Mounting bracket, instruction manual
E-87TL-N
TL
-N
Characteristic data (typical)
Sensing Distance vs. Sensing Object
TL-N5# TL-N7MD# TL-N12MD#
TL-N20MD# TL-N10# TL-N20#
0 10 20 30 40 50 60 70 80
Side length of sensing object d (mm)
Sen
sing
dis
tanc
e X
(m
m)
6
5
4
3
2
1
Stainless steel (SUS304)
Aluminum
Mild steel
Brass
#d t=1mmX
0 10 20 30 40 50 60
10
8
6
4
2
Side length of sensing object d (mm)
Sen
sing
dis
tanc
e X
(m
m)
Stainless steel (SUS304)
Aluminum
Mild steel
Copper
Brass
#d t=1mmX
0 10 20 30 40 50 60
14
12
10
8
6
4
2
Side length of sensing object d (mm)
Sen
sing
dis
tanc
e X
(m
m)
Aluminum
Mild steel
Copper
Brass
Stainless steel (SUS304)
#d t=1mmX
0 10 20 30 40 50 60
24
20
16
12
8
4
Side length of sensing object d (mm)
Sen
sing
dis
tanc
e X
(m
m)
Aluminum
Mild steel
Copper
Brass
Stainless steel (SUS304)
#d t=1mmX
0 10 20 30 40 50 60 70 80
Side length of sensing object d (mm)
Sen
sing
dis
tanc
e X
(m
m)
10
8
6
4
2
Stainless steel (SUS304)
Aluminum
Mild steel
Brass
#d t=1mmX
0 10 20 30 40 50 60 70 80
Side length of sensing object d (mm)
Sen
sing
dis
tanc
e X
(m
m)
22
20
18
16
14
12
10
8
6
4
2
Stainless steel (SUS304)
Aluminum
Mild steel
Brass
#d t=1mmX
E-88 Proximity Sensors
Output Circuit Diagram
DC 2-wire Models
DC 3-wire Models
AC 2-wire Models
Operating status
Model Timing chart Output circuit
NOTL-N7MD1TL-N12MD1TL-N20MD1
NCTL-N7MD2TL-N12MD2TL-N20MD2
Operating status
Model Timing chart Output circuit
NOTL-N5ME1TL-N10ME1TL-N20ME1
NCTL-N5ME2TL-N10ME2TL-N20ME2
Operating status Model Timing chart Output circuit
NOTL-N5MY1TL-N10MY1TL-N20MY1
NCTL-N5MY2TL-N10MY2TL-N20MY2
Sensing object
(%) 100 080(typ)
Stable sensing areaNon-sensing area
Rated sensing distance
Unstable sensing area
Setting point
Proximity Sensor
ON
OFF
ON
OFF
ON
OFF
Setting indicator (green)
Operation indicator (red)
Control output
LoadBrown
Blue
Main circuit
+V
0 V
Note: The load can be connected to either the +V or 0-V side.
Sensing object
(%) 100 0
Sensing distanceNon-sensing area
Rated sensing distance
Proximity Sensor
ON
OFF
ON
OFF
Operation indicator (red)
Control output
Yes
No
Operates
Releases
H
L
ON
OFF
Load(between brown and black)
Sensing object
Operation indicator (red)
Output voltage(between black and blue)
Load
Brown
Black* 1
* 2 Tr
* 1. 200 mA max.(load current)* 2. When a transistor is connected.
Output
Blue
100W
4.7kW
2.2W
Main circuit
+V
0V
Yes
No
Operates
Releases
H
L
ON
OFF
Load(between brown and black)
Sensing object
Operation indicator (red)
Output voltage(between black and blue)
Yes
No
Operates
Releases
ON
OFF
Load
Sensing object
Operation indicator (red)
Brown
Blue
Load
Maincircuit
Yes
No
Operates
Releases
ON
OFF
Load
Sensing object
Operation indicator (red)
E-89TL-N
TL
-N
Precautions
Do not short-circuit the load, otherwise the
TL-N may explode or burn.
Do not supply power to TL-N without load,
otherwise TL-N may be damaged (AC 2-
wire Models).
Design
Effects of Surrounding Metal
Provide a minimum distance between the Sensor and the
surrounding metal as shown in the table below.
Effects of Surrounding Metal(Unit: mm)
* The figures are applicable for one metal object, otherwise the figure must bemultiplied by the number of metal objects.
Mutual Interference
If more than one Sensor is located face to face or in parallel,
ensure to maintain enough space between adjacent Sensors
to suppress mutual interference as provided in the following
diagram.
Mutual Interference (unit: mm)
Note: Figures in parentheses will apply if the Sensors in use are different fromeach other in response frequency.
Mounting
Ensure that each screw is tightened with a torque within a
range of 0.9 to 1.5 Nm.
Warning
Correct Use
ModelLength A (see
note)B (see note)
TL-N7MD# 40 35
TL-N12MD# 50 40
TL-N20MD# 70 60
TL-N5ME#, TL-N5MY# 20 23
TL-N10ME#, TL-N10MY# 40 30
TL-N20ME#, TL-N20MY# 80 45
Model Length A B
TL-N7MD# 100(50) 120(60)
TL-N12MD# 120(60) 200(100)
TL-N20MD# 200(100) 200(100)
TL-N5ME# 80(40) 80(40)
TL-N5MY# 80(40) 90(40)
TL-N10ME#, TL-N10MY# 120(60) 120(60)
TL-N20ME#, TL-N20MY# 200(100) 120(60)
A
B
ASide-by-side Face-to-face
B
E-90 Proximity Sensors
Dimensions (Unit: mm)
Sensors
Two, 4.3 dia.35
6
25
25
0.51.5
* 1
38.5
18.5
23.8
18±0.45
Indicator * 2
Rubber bushing
* 1. 6-dia. two conductors vinyl-insulated round cable (cross-sectional area of conductors: 0.5 mm2; insulation diameter: 1.9 mm) Standard length: 2 m* 2. Operation indicator (red), Setting indicator (green)
Two, 4.5 dia. or M4 holes
18±0.2
CAD file TL_13TL-N7MD#
Mounting Holes
CAD file TL_09
Two, 4.3 dia.49
7.7
30
30
0.51.5
* 1
52.5
21.5
35.8
22±0.45
Indicator * 2
Rubber bushing
* 1. 6-dia. two conductors vinyl-insulated round cable (cross-sectional area of conductors: 0.5 mm2; insulation diameter: 1.9 mm) Standard length: 2 m* 2. Operation indicator (red), Setting indicator (green)
Two, 4.5 dia. or M4 holes
22±0.2
TL-N12MD#
Mounting Holes
TL-N20MD#
Two, 5.5 dia.47
8
40
40
1 53
30
31.8
30±0.45
Rubber bushing* 1
Indicator * 2
* 1. 6-dia. two conductors vinyl-insulated round cable (cross-sectional area of conductors: 0.5 mm2; insulation diameter: 1.9 mm) Standard length: 2 m* 2. Operation indicator (red), Setting indicator (green)
Two, 5.5 dia. or M5 holes
30±0.2
CAD file TL_10
Mounting Holes
CAD file TL_12
TL-N5MY#
Mounting Holes
Two, 4.3 dia.46.3
6.2
25
25
0.5 1.5
*
50
18.5
34.1
18±0.45
Operation indicator (red)
Rubber bushing
* 6-dia. two conductors vinyl-insulated round cable (cross-sectional area of conductors: 0.5 mm2; insulation diameter: 1.9 mm) Standard length: 2 m
Two, 4.5 dia. or M4 holes
18±0.2
CAD file TL_11
TL-N5ME#
Two, 4.3 dia.35
6
25
25
0.5 1.5
*
38.5
18.5
23.8
18±0.45
Operation indicator (red)
Rubber bushing
* 6-dia. two conductors vinyl-insulated round cable (cross-sectional area of conductors: 0.5 mm2; insulation diameter: 1.9 mm) Standard length: 2 m
Two, 4.5 dia. or M4 holes
18±0.2
Mounting Holes
Two, 4.3 dia.49
7.7
30
30
0.5 1.552.5
21.5
35.8
22±0.45
Rubber bushing
* 1. Y type: 6-dia. two conductors vinyl-insulated round cable (cross-sectional area of conductors: 0.5 mm2; insulation diameter: 1.9 mm) Standard length: 2 m
E type: 6-dia. three conductors vinyl-insulated round cable (cross-sectional area of conductors: 0.5 mm2; insulation diameter: 1.9 mm) Standard length: 2 m
* 2. E type: operation indicator (red) Y type: operation indicator (red)
* 1
Indicator * 2
Two, 4.5 dia. or M4 holes
22±0.2
Mounting Holes
TL-N10ME#, TL-N10MY#CAD file TL_09
E-91TL-N
TL
-N
Accessories (Order Separately)Mounting Brackets
*1. The numeric values are Mounting Bracket Holes dimensions.*2. Supplied with the product.
Mounting Bracket for Conduit
Two, 5.5 dia.47
8
40
40
1 53
30
31.8
30±0.45
Rubber bushing* 1
Indicator * 2
Two, 4.5 dia. or M4 holes
22±0.2
* 1. Y type: 6-dia. two conductors vinyl-insulated round cable (cross-sectional area of conductors: 0.5 mm2; insulation diameter: 1.9 mm) Standard length: 2 m
E type: 6-dia. three conductors vinyl-insulated round cable (cross-sectional area of conductors: 0.5 mm2; insulation diameter: 1.9 mm) Standard length: 2 m
* 2. E type: operation indicator (red) Y type: operation indicator (red)
Mounting Holes
TL-N20ME#, TL-N20MY# CAD file TL_10
Applicable Models: TL-N5ME# * 2 TL-N5MY# TL-N7MD# * 2
32
20 3.5
25
9.52.3
4.5
6.5
18±0.212 ±0.2
Two, M4
*1
Y92E-C5
7
Applicable Models: TL-N10ME# * 2 TL-N10MY# TL-N12MD# * 2
20
34
18
4
30
14.52.3
4.5
22±0.2* 1 16±0.2
Two, M4
Y92E-C10
Applicable Models: TL-N20ME# * 2 TL-N20MY# TL-N20MD# * 2
35
19.5 6
40
243.2
5.5
9
30±0.2* 1 22±0.2
Two, M5
Y92E-C20
Y92E-N5C15
25
18 2.3
23.85
2.3
3.511±0.2
Two, 4.3 dia.
C15 conduit screw
Applicable Models: TL-N5ME# TL-N5MY#
18±0.3
Y92E-N10C15
30
21 2.3
24.35.5
2.3
3.5
22±0.3
13±0.2Two, 4.3 dia.
C15 conduit screw
Applicable Models: TL-N10ME# TL-N10MY#
E-92 Proximity Sensors
Liquid Level Sensor
E2K-L Installation on pipes.
Sensing by means electrostatic capacity and is not
influenced by the color of the pipe or liquid.
Available in 8 to 11 mm dia. and 12 to 26 mm dia.
models to enable sensing for a wide range of pipe
diameters.
Built-in amplifier for space-saving.
Applications
Ordering Information
Sensor type Applicable pipe diameters Shape Output form Model
Electrostaticcapacity method
8 to 11 mm dia.
NPN open-collector output NO
E2K-L13MC1
12 to 26 mm dia. E2K-L26MC1
Liquid surface level detection
E-93E2K-L
E2K
-L
Rating/Performance
Note: In the following cases, stable detection may not be possible and ensure to confirm correct operation in the actual installation before use.1 . If the dielectric constant or conductivity of the liquid is low.2 . If the capacity of the liquid is small, or if the pipe diameter is so small or the pipe walls are so thick that the amount by which the capacity changes relating to
the liquid level is small.3 . In case of an increased gassing or a highly viscous liquid firm residue on the inside walls of the pipe, or a dirt clogging on the inner or outer walls of the pipe.
Item Model E2K-L13MC1 E2K-L26MC1
Applicable pipes
Material Non-metal
Size
External diameter
8 to 11 mm dia. 12 to 26 mm dia.
Wall thickness
1 mm max. 1.5 mm max.
Sensing object Liquid (see note)
Repetition precision ±0.2 mm max.
Response difference
0.6 to 5 mm 0.3 to 3 mm(reference value only; varies with pipe size and solution)
Supply voltage (operating voltage range)
12 to 24 VDC, 10% max. ripple (10.8 to 30 VDC)
Current consumption 12 mA max.
Control output
Switching capacity
100 mA max.
Residual voltage
1 V max. (under load current of 100 mA with cable length of 2 m)
Detection position of liquid surface Notch position (For details, refer to Sensitivity Adjustment on next page.)
Indicator lamp Operation indicator (orange)
Ambient temperature Operating: 0 to 55°C; Storage: -10 to 65°C (with no icing or condensation)
Ambient humidity Operating/storage: 25% to 85% (with no condensation)
Temperature influence In the range 0 to 55°C: Detection level at 23°C 4 mm (with distilled water or 20 % salt water concentration) (±6 mm with E2K-L13MC1 for distilled water in pipe of 8 mm diameter)
Voltage influence At the rated power supply voltage ±10%: Detection level at rated supply voltage ±0.5 mm
Insulation resistance 50 M min. (at 500 VDC) between energized parts and case
Dielectric strength 500 VAC 50/60 Hz for 1 min between energized part and case
Vibration resistance 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance 500 m/s2 for 3 times each in X, Y, and Z directions
Protective structure IEC 60529 IP66
Connection method Pre-wired models (standard length: 2 m)
Weight (Packed state) Approx. 70 g
MaterialCase, cover Heat-resistant ABS resin
Cable clamp NBR
Accessories 2 binding bands, 4 nonskid tubes, instruction manual
E-94 Proximity Sensors
Characteristic data (typical)Influence of Temperature on Detection Level
Output Circuit Diagram
OperationSensitivity adjustment1. Install the Sensor with the setting position (notch) in line
with the liquid level to be detected.2. After Sensor installation adjust the detecting sensitivity using
the (12-step) sensitivity adjuster in the way shown below.
Note: 1 .During sensitivity adjustment do not put your hand on the Sensor andmake sure that the cable is properly secured. Failure to observe thesepoints may affect the detection level.
2 .When using more than one Sensor (e.g., to detect for upper and lowerlimits), adjust the sensitivity of the Sensors in order starting from thebottom. Adjusting the sensitivity of a Sensor may affect the detectionlevel of the Sensor above it.
E2K-L13MC1 E2K-L26MC1
Output form Model Timing chart Output circuit
NO E2K-L13MC1E2K-L26MC1
Cha
nge
in d
etec
tion
leve
l (m
m) 6
4
2
0
-2
-4
-6
Pipe diameter: 11 mm; Liquid: Distilled waterPipe diameter: 11 mm; Liquid: Salt wateripe diameter: 8 mm; Liquid: Distilled waterPipe diameter: 8 mm; Liquid: Salt water
-10 02010
30 40 50 60Temperature (C˚)
6
4
2
0
-2
-4
-6
Pipe diameter: 26 mm; Liquid: Distilled waterPipe diameter: 26 mm; Liquid: Salt waterPipe diameter: 12 mm; Liquid: Distilled waterPipe diameter: 12 mm; Liquid: Salt water
-10100
20 30 40 50 60
Cha
nge
in d
etec
tion
leve
l (m
m)
Temperature (C˚)
Yes
No
Operates
Releases
ON
OFF
Load(brown-black)
Operation indicator(orange)
Liquid surface
Brown+V
0V
Black*
* 100 mA max. (load current)
Blue
Maincircuit
Load
Setting position(notch)
Pipe
Sensor
Level ofliquid surface
Status of the indicator when the liquid level is aligned with the setting position
Sensitvity adjuster Adjustment procedure
Not litTurn the sensitivity adjuster clockwise using a screwdriver until the indicator lights.
Lit
Turn the sensitivity adjuster counterclockwise using a screwdriver until the indicator turns OFF. Then, turn the sensitivity adjuster clockwise until the indicator lights up again.
1
1
2
2. Then set the upper limit.
1. First set the lower limit.
E-95E2K-L
E2K
-L
Precautions
Design
Influence of Surrounding Objects
Performance may be adversely affected by conductive ob-
jects (e.g., metals) in the vicinity of the Sensor. Ensure that
any conductive objects are separated from the Sensor and
set at a minimum distance as shown below.
Influence of Surrounding Objects (Units: mm)
Mutual Interference
When installing 2 or more Sensors in series, in parallel, or fac-
ing each other, be sure that they are separated by at least the
distances shown below.
Mutual Interference (Unit: mm)
* The detection level for the top Sensor may change when the detection levelfor the bottom Sensor is set. Be sure to set the detection level for the bottomSensor first.
Installation
Sensor installation
Attach the Sensor securely to the pipe using the 2 binding
bands and the 4 nonskid tubes provided (2 tubes per band) in
the way shown below.
Install the Sensor in such manner that the pipe is in contact
with the entire sensing face of the Sensor with the pipe and
Sensor in parallel.
Wiring Considerations
Power Supply
If separate power supplies are used for Sensor and load, besure to turn on the Sensor power supply first.If a commercially available switching regulator is used, theSensor may malfunction because of switching noise. Connectthe frame ground and ground terminals to ground.
Operating Environment
Ambient Conditions
Although this product has waterproof specifications, do not useit in locations where it may have a direct contact with liquids(e.g., water or cutting oil). Such locations can interfere with theelectrostatic capacity method used by the Sensor.Even if the Sensor is used within the specified temperaturerange, do not subject it to sudden changes in temperature be-cause this will shorten the service life.
Miscellaneous
Drift may occur when the power supply is turned ON. If the di-electric constant of the liquid is low, the detection level of theliquid may be 2 to 3 mm higher than the set level for approxi-mately 20 minutes after power is turned ON.
Correct Use
Shape Length A B C
E2K-L13MC125
5 45
E2K-L26MC1 0 40
Shape Length D (see note) E F
E2K-L13MC110 10
25
E2K-L26MC1 30
C
B
A
SensorPipe
Object on Opposite Side
Object on One Side Objects on Both Sides
Installed in Parallel Installed in Facing Each Other
FE
Installed in Series Sides
D
Sensor
Level ofliquid surface
Pipe
Slip-prevention tubes
Slip-prevention tubes
Binding bands
Setting position(notch)
Binding bands
Operation indicatorSensitivityadjuster
SensorPipe
Side View Front View
Top View
E-96 Proximity Sensors
Dimensions (Unit: mm)
E2K-L13MC1
20
5
43 41 33
R6.5
24
11
5
1.5
6.5
1
3.56
6
Sensitivity adjuster
Operation indicator (orange)
4.5
Mounting holes
4
R17.5
2.9-dia. three conductors vinyl-insulated round cable(cross-sectional area of conductors: 0.14 mm2;insulation diameter: 0.9 mm) Standard length: 2 m
Sensing surface
E2K-L26MC1
20
R13
33
11
3
6.5
1
6Operation indicator(orange) Sensitivity adjuster
4.5
3.5
6
2
1.5
Mounting holes
34 32 24
R17.5
5
2.9-dia. three conductors vinyl-insulated round cable(cross-sectional area of conductors:0.14 mm2;insulation diameter: 0.9 mm) Standard length: 2 m
Sensing surface
MEMO
E-97E2K-L
E2K
-L
E-98 Proximity Sensors
Long-distance capacitive proximity sensor
E2K-CCapacitive Proximity Sensorwith Adjustable Sensitivity Detects both metallic and non-metallic objects
(glass, lumber, water, oil, plastic, etc.) without
direct contact.
DC models acquire CE marking
Ordering Information
Sensors
Accessories (Order Separately)Mounting Brackets
Shape Sensing distanceModel
Output specificationsOperating status
NO NCDC 3-wire NPNDC 3-wire PNP
E2K-C25ME1E2-KC25MF1
E2K-C25ME2E2K-C25MF2
AC 2-wire Models E2K-C25MY1 E2K-C25MY2
Shape Model Quantity Remarks
Y92E-A34 1 Supplied with the product.
34 dia.
Unshielded
3 to 25mm
E-99E2K-C
E2K
-C
Rating/Performance
* The set distances are sensing distances applicable to standard sensing objects. Refer to Engineering Data for sensing distances applicable to other types of objects.
Item Model E2K-C25M#1 E2K-C25M#2 E2K-C25MY1 E2K-C25MY2
Sensing distance * 25 mm
Sensing distance adjustable range
3 to 25 mm
Sensing object Conductors and dielectrics
Standard sensing object with grounded metal: 50 x 50 x 1t mm
Differential distance 15% max. of sensing distance (when adjusted to 25 mm ±10% with standard object)
Response frequency 70 Hz 10 Hz
Power supply(Operating voltage range)
12 to 24 VDC, ripple (p-p): 10% max.,(10 to 40 VDC) 100 to 220 VAC (90 to 250 VAC) 50/60 Hz
Current consumption E models: 10 mA max. at 12 VDC, 16 mA max. at 24 VDC
Leakage currentY models: 1 mA max. at 100 VAC (50/60 Hz) with output turned OFF., 2 mA max. at 200 VAC (50/60 Hz) with output turned OFF.
Control output
Switching capacity
200 mA max. 5 to 200 mA (resistive load)
Residual voltage
2 V max. (under load current of 200 mA with cable length of 2 m)
Indicator lamp Detection indicator (red LED) Operation indicator (red LED)
Operating status (with sensing object approaching)
E1, Y1 models: NOE2, Y2 models: NC
Protective circuits Reverse connection protection, surge absorber Surge absorber
Ambient temperature Operating/Storage: -25°C to 70°C (with no icing or condensation)
Ambient humidity Operating/Storage: 35% to 95%RH (with no condensation)
Temperature influence ±15%max. of sensing distance at 23° within temperature range -10°C to 55°C
Voltage influence±2% max. of sensing distance at a voltage between 85% and 115% of the rated power supply voltage
±2% max. sensing distance at a voltage ranging from 90% to 120% of a rated power voltage of 100 VAC and from 80% to 120% of a rated supply voltage of 200 VAC
Insulation resistance 50 M min. (at 500 VDC) between current carry parts and case
Dielectric strength1000 VAC 50/60 Hz for 1 min between energized part and case
1,500 VAC 50/60 Hz for 1min between energized part and case
Vibration resistance 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 500 m/s2 for 10 times each in X, Y, and Z directions
Protective structure IEC 60529 IP66
Connection method Pre-wired models (standard length: 2 m)
Weight (Packed state) Approx. 200 g
Material
Case
Heat-resistant ABS resinSensing surface
Accessories Mounting bracket, instruction manual
E-100 Proximity Sensors
Characteristic data (typical)
Sensing Distance Change by Sensing Object (Typical)
Output Circuit Diagram
DC 3-wire Models
Operating status
Model Timing chart Output circuit
NO E2K-C25ME1
NC E2K-C25ME2
NO E2K-C25MF1
NC E2K-C25MF2
25
20
15
10
5
0
Sen
sing
dis
tanc
e X
(m
m)
Stan
dard
sens
ing o
bject
(50
x 50
x t1
)
Phe
nol r
esin
(5
0 x
50 x
15)
Neo
pren
e ru
bber
(5
0 x
50 x
15)
Gla
ss
(200
x 5
0 x
t3)
Lava
n pl
ate
(160
x 1
20 x
t15)
Res
in p
elle
t (D
urac
on)
500
ml m
ilk
(pur
e w
ater
)
Flo
ur
Sug
ar
Sal
t
Yes
No
Operates
Releases
H
L
ON
OFF
Load (between brown and black)
Output voltage (between black and blue)
Operation indicator (red)
Sensing object
Main circuit
Load
Brown
Brack *1
Output *2
Blue
4.4kW
+V
0V
Tr
* 1. 200 mA max. (load current)* 2. When a transistor is connected
Yes
No
Operates
Releases
H
L
ON
OFF
Load (between brown and black)
Output voltage (between black and blue)
Operation indicator (red)
Sensing object
Yes
No
Operates
Releases
H
L
ON
OFF
Load (between brown and black)
Output voltage (between black and blue)
Operation indicator (red)
Sensing object
Brown+V
Tr
Black*2
*12.2W
4.7kWBlue
0V
Output
Maincircuit
100WLoad
* 1. Maximum load current: 200 mA* 2. Current flows in this directionif the circuit incorporates the transistor.
Yes
No
Operates
Releases
H
L
ON
OFF
Load (between brown and black)
Output voltage (between black and blue)
Operation indicator (red)
Sensing object
E-101E2K-C
E2K
-C
AC 2-wire Models
Operating status
Model Timing chart Output circuit
NO E2K-C25MY1
NC E2K-C25MY2
Yes
No
Operates
Releases
ON
OFF
Load
Operation indicator (red)
Sensing object
Brown
Blue
Load
Main circuit
Yes
No
Operates
Releases
ON
OFF
Load
Operation indicator (red)
Sensing object
E-102 Proximity Sensors
Operation
Sensitivity adjustment
Remove the rear rubber cap of the E2K-C and turn the poten-
tiometer in the hole to adjust the sensitivity of the E2K-C.
The sensing distance increases by turning the potentiometer
clockwise and decreases by turning the potentiometer coun-
terclockwise. The potentiometer can make 15±3 valid turns
and then make slip turns because the potentiometer does not
have a stopper. The slip turns will not, however, damage the
potentiometer.
1. Slowly turn the potentiometer clockwise until the E2K-C
turns on with no sensing object.
2. Turn the potentiometer counterclockwise until the E2K-C
turns off with the sensing object located within the sensing
distance.
3. The E2K-C will be in stable operation if there is a difference
of 1.5 turns or more between the points the E2K-C is turned
on and off, otherwise the E2K-C will not be in stable oper-
ation.
4. Set the potentiometer midway between the two points.
5. If the distance of each sensing object varies, take step 2
with the sensing object located at the farthest sensing dis-
tance to be applied.
Precautions
Design
Effects of Surrounding Metal
During Proximity Sensor installation provide a distance of 80
mm min. from the surrounding metal objects to prevent the
Sensor from being affected by metal objects other than the
sensing object.
If installing the Sensor with the L-shaped mounting bracket,
provide a distance of 20 mm min. between the face of the
sensing head and the mounting bracket.
Mutual Interference
Space the two Sensors at a distance exceeding 100 mm to
prevent mutual interference.
Effect of High-frequency Electro-magnetic Field
The E2K-C may malfunction if there is an ultrasonic washer,
high-frequency generator, transceiver, or inverter nearby.
Remove this rubber cap and adjust the potentiometer.
Potentiometer
Stop turning the potentiometer at the moment the E2K-C turns off.
Potentiometer
Stop turning the potentiometer at the moment the E2K-C turns off.
The point the E2K-C turns on.
The point the E2K-C turns off.
Stable detection if the difference is 1.5 turns or more.
The point the E2K-C turns on.
The point the E2K-C turns off.
Midway
Correct Use
20 mm min. 80 mm min.
80 mm min. 80 mm min.
80 mm min.
Sensing surfaceMetal
Be sure to ground
Surrounding conductive object
Surrounding conductive object
100 mm min.
100 mm min.
Face-to-dace Mounting Parallel Mounting
E-103E2K-C
E2K
-C
Sensing Object
Sensing Object Material. The E2K-C can detect almost any
type of object. The sensing distance of the E2K-C, however,
will vary with the electrical characteristics of the object, such
as the conductance and inductance of the object, and the
water content and capacity of the object. The maximum
sensing distance of E2K-C will be available if the object is
made of grounded metal.
Indirect Detection. In the case of the detection of objects in
metal containers, each metal container must have a non-
metallic window.
Miscellaneous
Organic Solvents
E2K-C has a case made of heat-resistant ABS resin. Be sure
that the case is free from organic solvents or solutions con-
taining organic solvents.
Dimensions (Unit: mm)
Sensors
Accessories (Order Separately)*
E2K-C25M##
* E models: Detection indica-tor (red); Y models: Opera-tion indicator (red)
82
34 dia.
20
7
Cap cord13
Cord clamp
Screw hole for sensitivity adjustment
Operation indicator *E type: 6-dia. three conductors vinyl-insulated round cable (cross-sectional area of conductors: 0.5 m‡u; insulation diameter: 1.9 mm) Standard length: 2 mY type: 6-dia. two conductors vinyl-insulated round cable (cross-sectional area of conductors: 0.5 m‡u; insulation diameter: 1.9 mm) Standard length: 2 m
CAD file E2K_01
L-shaped Mounting BracketY92E-A34
* Attached to the product.
45
436.3
5.2R2.6
Two elliptic holes for bracket mounting
352
23.515
Two, M4 sensor clamping screws42
30
35
6
E2K Proximity SensorWith Mounting Bracket Attached
* The holes are not drilled straight through. Drill through the holes before using them.
Sensor mounting holes
Two, 5.5-dia. mounting holes *
54.4
45
57.6
51
14
30
E-104 Proximity Sensors
10 mm
Flat type
E2K-FLow-profiled Capacitive Proximity Sensor providingFlexible Installation
Ordering Information
* NC models available (E2K-F10MC2)
Rating/Performance
Shape Sensing distanceOutput
specificationsOperating
statusModel
DC 3-wire NPN NO * E2K-F10MC1
Item E2K-F10MC1Sensing distance 10 mm ±10%Setting distance 0 to 7.5 mmDifferential distance 15% max. sensing distanceSensing object Conductors and dielectricsStandard sensing object with grounded metal: 50 x 50 x 1 mmResponse frequency 100 HzRated supply voltage (operating voltage) 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
Current consumption 10 mA max. (24VDC)Control output
Switching capacity NPN open collector 100 mA max. (under 30 VDC)Residual voltage 1.5 V max. (under load current of 100 mA with cable length of 2 m)
Indicator lamp Detection indicator (red LED)Operating status (with sensing object approaching) NO
Protective circuits Reverse connection protection, surge absorberAmbient temperature Operating/Storage: -10°C to 55°C (with no icing or condensation)Ambient humidity Operating/Storage: 35% to 95%RHTemperature influence ±15% max. of sensing distance at 23°C within the temperature range of -10°C and 55°CVoltage influence ±2.5% max. of sensing distance within a range of ±10% of rated supply voltageInsulation resistance 50 M min. (at 500 VDC) between energized parts and caseDielectric strength 500 VAC 50/60 Hz for 1 min between energized part and caseVibration resistance Malfunction: 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y, and Z directionsShock resistance Destruction: 500 m/s2 for 3 times each in X, Y, and Z directionsProtective structure IEC 60529 IP66Connection method Pre-wired models (standard length: 2 m)Weight (Packed state) Approx. 35 g
MaterialCase
Heat-resistant ABS resinSensing surface
Accessories Instruction manual
Flat typeUnshielded
E-105E2K-F
E2K
-F
Precautions
Design
Sensing Object Material
E2K-F can detect almost any type of object. The sensing dis-
tance of E2K-F, however, will vary with the electrical charac-
teristics of the object, such as the conductance and
inductance of the object, as well as the water content and ca-
pacity of the object. The maximum sensing distance of E2K-F
will be available if the object is made of grounded metal.
There are objects that cannot be detected indirectly. There-
fore test E2K-F in a trial operation with the objects before us-
ing E2K-F in actual applications.
Effects of Surrounding Metal
Separate E2K-F from ambient metals as shown below.
Mutual Interference
If installing more than one E2K-F face to face or side by side,
separate them as shown below.
Effect of High-frequency Electro-magnetic Field
E2K-F may malfunction if an ultrasonic washer, high-frequen-
cy generator, transceiver, or inverter are nearby.
For a typical measure, refer to the "Noise" with Common pre-
cautions of a photoelectric sensor in Rear B-page.
Wiring Considerations
The characteristics of E2K-F will not change if the cord is ex-
tended. Keep in mind that voltage drops may occur due to the
cord extension, thus, ensure that the total cord length does
not exceed 200 m.
Characteristic data (typical)
Sensing Distance vs. Sensing Object
Grounded metal (t=1)
Ungrounded metal (t=10)
Glass (t=10)
Phenol resin (t=10)
10
9
8
7
6
5
4
3
2
1
0 10 20 30 40 50 60 70 80
Sensing object size (mm)
Sen
sing
dis
tanc
e X
(m
m)
Output Circuit Diagram
Operating Chart
Output circuit
Yes
No
ON
OFF
ON
OFFOperation indicator
(red)
Sensing object
Output transistor (load)
NO Type
100W
Brown
Brack
Output
Blue
+V
0V
Load
Main circuit
* 100 mA max. (load current)
*
Correct Use
60mm
Metal object
45mm
30mm
Metal object Metal object
40mm
50mm 50mm
Close mounting possible Face-to-face mounting
E-106 Proximity Sensors
Dimensions (Unit: mm)
E2K-F
5
10.1
20 5
10
*50 42 34
8
Operation indicator (red)
Two, 3.5 dia.
Two, 3.5 dia.
42±0.2
* 2.9-dia. three conductors vinyl-insulated round cable (cross-sectional area of conductors: 0.14 mm2; insulation diameter: 0.9 mm) Standard length: 2 m
Mounting Holes
CAD file E2K_02
MEMO
E-107E2K-F
E2K
-F
E-108 Proximity Sensors
Inductive Proximity Sensor
E2KQ-XProximity Sensor with Easy Sensing Distance Adjustment and Teflon * CoatingEffective Oil and Chemical Resistance Oil and chemical-resistant Teflon case.
Sensitivity adjuster ensures easy sensing distance
adjustment according to the sensing object.
Incorporates a cord connector with an indicator
providing high visibility.
* Teflon is a registered trademark of Dupont Company and Mitsui Du-pont Chemical Company for their fluoride resin.
Ordering Information
* NC models available (E2KQ-X10ME2)
Characteristic data (typical)
Shape Sensing distance OutputOperating
statusModel
M18DC 3-wire
NPNNO * E2KQ-X10ME1
Sensing Distance vs. Sensing Object Sensing Object Thickness and Material vs. Sensing Distance
Unshielded6 to 10 mm
Grounded metal
Ungrounded metal
Phenol resin
Glass
15
10
5
0
Sen
sing
dis
tanc
e X
(m
m)
0 10 20 30 40 50 60 70 80
Side length of sensing object d (mm)
#d t=3mmX
Grounded metal
Ungrounded metal
Phenol resin
Acrylic resin
Wooden plate
Glass
15
10
5
0
Sen
sing
dis
tanc
e X
(m
m)
0 5 10 15 20 25 30
Sensing object width t (mm)
#50t
X
E-109E2KQ-X
E2K
Q-X
Output Circuit Diagram
DC 3-wire Models
Rating/Performance
* This sensing distance is possible with a standard sensing object. Refer to Engineering Data for sensing distances of other materials.
Operatingstatus
Model Timing chart Output circuit
NO E2KQ-X10ME1
Item Model E2KQ-X
Sensing distance * 10 mm
Sensing distance adjustable range 6 to 10 mm
Differential distance 4% to 20% of sensing distance
Sensing object Conductors and dielectrics
Standard sensing object with grounded metal: 50 x 50 x 1t mm
Response frequency 35 Hz
Rated supply voltage (operating voltage)
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
Current consumption 15 mA max.
Control outputSwitching capacity 100 mA
Residual voltage 1.5 V max. (under load current of 100 mA with cable length of 2 m)
Indicator lamp Detection indicator (red LED)
Operating status (with sensing object approaching)
Refer to previous pages for details of operating chart of output circuits.
Protective circuits Reverse connection protection, surge absorber
Ambient temperature Operating: -10°C to 55°C, Storage: -25°C to 55°C (with no icing or condensation)
Ambient humidity Operating/Storage: 35% to 85%RH (with no condensation)
Temperature influence ±15% max. of sensing distance at 23°C in the temperature range of -10°C and 55°C
Voltage influence 2% max. sensing distance within a range of 80% to 120% of the rated supply voltage.
Insulation resistance 50 M min. (at 500 VDC) between energized parts and case
Dielectric strength 500 VAC 50/60 Hz for 1 min between energized part and case
Vibration resistance 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 500 m/s2 for 3 times each in X, Y, and Z directions
Protective structure IEC IP66
Connection method Pre-wired models (standard length: 2 m)
Weight (Packed state) Approx. 150 g
Material
Case, Sensing surface Fluororesin
Clamping nut
Accessories Instruction sheet and screwdriver for adjustment
Yes
No
Operates
Releases
H
L
ON
OFF
Sensing object
Load (between brown and black)Output voltage (between black and blue)
Operation indicator (red) * 1. 100 mA max. (load current)
* 2. When a transistor is connected
Tr
Main circuit
4.7kW
Brown
Blue
Black * 1
Output * 2
+V
0V
Load
E-110 Proximity Sensors
Precautions
Design
Effects of Surrounding Metals
If E2K-X is embedded in metal, maintain at least the following
distances between E2K-X and the metal.
* Ensure to ground the metal object, otherwise E2KQ-X will not be in stable op-eration.
Effects of Surrounding Metal (Unit: mm)
If a mounting bracket is used, be sure that at least the follow-
ing distances are maintained.
Mutual Interference
If more than one Sensor is located face to face or in parallel,
provide sufficient space between adjacent Sensors to sup-
press mutual interference as indicated in the following dia-
gram.
Mutual Interference (Unit: mm)
Effect of High-frequency Electro-magnetic Field
E2KQ-X may malfunction if there is an ultrasonic washer,
high-frequency generator, transceiver, or inverter nearby. For
a typical measure refer to the "Noise" with Common precau-
tions of a photoelectric sensor in Rear B-page.
Installation
The tightening torque must not exceed the following value.
Adjustment
Sensing object
The maximum sensing distance will decrease if the sensing
object is a metal or dielectric object that is not grounded.
Sensing Object Material E2K-C can detect almost any type
of object. The sensing distance of E2K-C, however, will
vary with the electrical characteristics of the object, such as
the conductance and inductance of the object, and the wa-
ter content and capacity of the object. The maximum sens-
ing distance of E2K-C will be available if the object is made
of grounded metal.
Ensure a constant ambient operating temperature during the
indirect detection of objects.
Miscellaneous
Ambient Conditions
Ensure that the E2K-X is free from sprayed water, oil, chemi-
cal, or condensation, otherwise E2K-X may malfunction by
detecting them as sensing objects.
Environment
E2KQ-X has a water-resistant design. To increase the reliabil-
ity of E2KQ-X in operation, however, it is recommended that
E2KQ-X is free from sprayed water or machining oil.
The cord is not coated with Teflon, which must be taken into
consideration when installing the E2KQ-X.
Dimensions (Unit: mm)
Correct Use
ModelLength l d m n
E2KQ-X10ME1 30 75 18 90
Model Length A B
E2KQ-X10ME1 200 32
l
d dia.
Be sure to ground Metal
mn
Effects of Surrounding Metal (Unit: mm)
Model Length G H
E2KQ-X10ME1 30 35
G
H
A B
Model Tensile strength (torque)
E2KQ-X10ME1 0.6 Nm
CAD file E2KQ_01E2KQ-X10ME1
24
Fluoride resin61.8
20 8
16 dia.
M18 x 1.5Fluoride resin Two, clamping nuts
coated with fluoride resin
Operation indicator (red)Indicator
Sensitivity adjuster
18.5 dia.+0.5 -0
6-dia. three conductors vinyl-insulated round cable (cross-sectional area of conductors: 0.5 mm2; insulation diameter: 1.9 mm) Standard length: 2 m
Mounting Dimensions
E-111Y92#
Y92
#
Mounting Bracket
Four kinds of resin mounting brackets are avail-
able.
Choose an appropriate one depending on external
dimensions.
Accessories
A cover is available for sensor head protection.
Choose an appropriate one depending on external
dimensions.
Sputter Protection Covers
Accessories
Y92#
Mounting Holes Dimensions
Note: If using the Mounting Brackets for Non-shielded models, pay attention to the influence ofsurrounding metals. (For dimensions of Sensors, refer to the dimensions shown for eachmodel.)
Item Length (mm) Use hexag-onal bolts
Applicable diameter of
sensorsModel A B C D E F
Y92E-B8 18 ± 0.2 10 max.
188-mm dia.
28 max.
6 M4 x 20 M8
Y92E-B12 24 ±0.2 12.5 max.
2012-mm dia.
37 max.
6 M4 x 25 M12
Y92E-B18 32 ±0.217 max. 30
18-mm dia.
47 max.
7 M5 x 32 M18
Y92E-B30 45 ±0.2 17 max.
5030-mm dia.
60max.
10 M5 x 50 M30
A
B
F
C
E
D
Protective Covers Dimensions
Item Length (mm)Material Applicable sen-
sor diameterModel A B C
Y92E-E12 14-mm dia. 5 0.5
Polyallylate resin
M12Shielded
Y92E-E18 21-mm dia. 6 1 ±0.2M18
Shielded
Y92E-E30 33-mm dia. 8 1.5 ±0.2M30
Shielded
Y92E-E12M 14-mm dia. 12 0.5M12
Unshielded
Y92E-E18M 21-mm dia. 16 1 ±0.2M18
Unshielded
Y92E-E30M 33-mm dia. 21 1.5 ±0.2M30
Unshielded
+0.2
-0.1
+0.2
-0.1
B
C
A
Sputter Protection Covers Dimensions
Item Length (mm)Material
Applicable sen-sor diameterModel A B C D
Y92E-E12-211.0 mm-
dia.14.0 mm-
dia.5.0 1.0
Silicone rubber
M12Shielded
Y92E-E18-2 17.0 dia. 21.0 dia. 6.0 3.0 M18Shielded
Y92E-E30-2 28.5 dia. 33.0 dia. 8.0 6.0 M30Shielded
CD
BA
C0.5
C0.5 C0.5
1-dia. through
MEMO