CONTA-CONNECT
General accessories for CONTA-CONNECT
The CONTA-CLIP line of accessories is conceived and designed with the cus-tomer in mind. Our accessories allow you to move forward on a great numberof technical applications with a minimum of effort and parts.
264264
265265
General accessories for CONTA-CONNECT
Overview
GEN
ERA
L A
CC
ESSO
RIE
S
265
DIN rails
A wide variety of DIN rails are available, in two-meter sectionsor pre-cut as required. They vary in shape, size and material.They fit on various rail types ((C profile TS 32, Automatic pro-file TS 35, compact rail TS 15), are made from steel, copper orPVC, and are available in slotted or unslotted versions.
End stops | End supports
End stops are necessary for preventing movement of compo-nents along the rail. They are put in at the beginning and atthe end of the rail assembly. Depending on the DIN rail, theydiffer in the dimensions of the mounting foot and their screw-on or snap-on design. End stops can also be used to hold avariety of group marker holders. An end support with screwflange or snap-in clip ensures that the terminal block is secure-ly attached to the mounting plates.
Group marker holders
Group marker holders allow you to clearly label terminal stripconfigurations. They are available in a variety of versions.Adhesive labels, paper strips or standard terminal markers areused for the labelling.
End plates | Visual separation
End plates are normally attached to the end or to the transitionfrom a larger to a smaller terminal block. They ensure that thereis enough insulation (touch protection) for the current-carryingsection.
266
CONTA-CONNECT
General accessories for CONTA-CONNECT
Overview
266266
Cross-connectors
Cross-connectors save you time when distributing similarpotentials or signals in a large number of electrical connec-tions. They are either pluggable or screwable and are avail-able with from 2 to 99 poles. The terminal block design andthe variability of the cross-connector ensure excellent flexibili-ty.
External cross-connector
External cross-connection bridges make it possible to branchoff the current for terminal blocks which do not have a cross-connection channel or when an additional potential needs tobe cross-connected. The attachment is at the clamping pointof the terminal. As a result, the rated cross-section of the ter-minal block must be reduced to the next smallest wire cross-section.
Covers
VDE regulations require that the mains connection terminalsare mounted before the main switch be covered. The yellowcovers (labelled with a lightning flash) are used to cover thecross-connection and operational channels. Thus they dis-courage operation of the terminal while live voltage is pres-ent.
Partition plates
Partition plates are attached within a terminal strip assembly sothat there is a clear visual separation of the different voltagelevels. When used, they also serve to extend the creepage andclearance distances (increased rated voltage).
Testing and inspecting
A direct measurement can be carried out at the busbar on thescrew-connection terminal by using a PS test plug and attach-ing a socket plug. The test adapters can be assembled to anypole counts using the locking pegs. They can be used to testassembled terminal blocks in a quick and safe manner.
267267
General accessories for CONTA-CONNECT
Overview
267
Reducing sleeves
The ZRH tension-spring reducing sleeves allow you tosecurely attach a small wire in a terminal point without splay-ing off the individual strands.
Fuse holders
The plug-in fuse holders are available as models with or with-out a status display. When used together with the base termi-nals, they provide excellent flexibility, ease of use, and a largevariety in the 5x20 mm micro-fuse range.
Fuse cartridges
G fuses are available in the 5 x 20 mm and 6.3 x 32 mmsizes, and in the “slow-acting” and “fast” versions. They areused with the STK/SIK/SK/ZTRK fused terminals and fuse-disconnect terminals. Additional auto-fuses, in compliancewith DIN 72581, are available for fused terminal blocks inpressure-spring and tension-spring connection systems.
Specific accessories, test-disconnect terminals PTK
In addition to the standard accessories, the test-disconnectterminal product line includes many special articles. Internaland external cross-switch bridges, socket plugs and short-cir-cuit plugs, for example, are required for constructing asecure terminal strip unit for measurement circuit applica-tions.
Actuating tools
The fully-insulated BW 1 to BW 10 tools and the BWMAmetallic tools can be used to actuate the pressure springsand tension springs in terminal blocks with cross-sections of2.5 mm2.
GEN
ERA
L A
CC
ESSO
RIE
S
268
CONTA-CONNECT
268
CONTA-CONNECT
TS DIN rails
TS 32
TS 322025.0
Steelunslotted
TS 32
TS 322093.0
Steelslotted 5.2 x 18
Qty.
2 m
Qty.
2 m
268
TS 35
TS 35 x 7.5 galvanized4562.0
Galvanized steelunslotted
TS 35
TS 35 x 7.5 galvanized4563.0
Galvanized steelslotted 5.2 x 18
TS 35
TS 35 x 152027.0
Steelunslotted
Qty.
2 m
Qty.
2 m
Qty.
2 m
DIN rails TS 32 / TS 35
The design of the TS DIN rail complies with the European normDIN EN 60715. The steel DIN rail is galvanized and has a coatingof blue chromate that is at least 10 µm thick. We place extraimportance on maintaining a high degree of dimensional accura-cy. The steel DIN rails can be used as protective-earth busbars(with PE function) in compliance with DIN VDE 0611 part 3.Please note the following when using the rail as a PEN busbar:
• Only one E-Cu rail should be used.• The short-circuit currents and the rated thermal currents
must be observed.
The DIN rails are delivered in standard lengths of 2 meters.All DIN rails are also available in prepared (cut to length)versions, but all types are available pre-cut to customersrequirements.
TypeTypeCat. no.Type/colourCat. no.FeaturesMaterialProcessing
DIN rails TS 35
TypeTypeCat. no.Type/colourCat. no.FeaturesMaterialProcessing
269
TS 35
TS 35 x 7.52026.0
Steelunslotted
TS 35
TS 35 x 7.52094.0
Steelslotted 5.2 x 18
TS 35
TS 35 x 7.52704.0
Steelslotted 6,2 x 18
TS 35
TS 35 x 7.5 ALU2710.0
Aluminiumunslotted
269
Qty.
2 m
TS 35
TS 35 x 152095.0
Steelslotted 5.2 x 18
TS 35
TS 35 x 154566.0
Steelslotted 6.2 x 18
TS 35
TS 35 x 15/2.32038.0
Steelunslotted
TS 35
TS 35 x 15/2.32039.0
Steelslotted 5.2 x 18
TS 35
TS 35 x 15 galvanized4561.0
Galvanized steelunslotted
Qty.
2 m
Qty.
2 m
Qty.
2 m
Qty.
2 m
Qty.
2 m
Qty.
2 m
Qty.
2 m
Qty.
2 m
GEN
ERA
L A
CC
ESSO
RIE
S
CONTA-CONNECT
270
CONTA-CONNECT
TS DIN rails
TS 35
TS 35 x 15 galvanized4564.0
Galvanized steelslotted 5.2 x 18
TS 35
TS 35 x 15 PVC2372.0
PVCunslotted
Qty.
2 m
Qty.
2 m
270
DIN rails TS 35
The design of the TS DIN rail complies with the European normDIN EN 60715. The steel DIN rail is galvanized and has a coatingof blue chromate that is at least 10 µm thick. We place extraimportance on maintaining a high degree of dimensional accura-cy. The steel DIN rails can be used as protective-earth busbars(with PE function) in compliance with DIN VDE 0611 part 3.Please note the following when using the rail as a PEN busbar:
• Only one E-Cu rail should be used.• The short-circuit currents and the rated thermal currents
must be observed.
The DIN rails are delivered in standard lengths of 2 meters.All DIN rails are also available in prepared (cut to length)versions, but all types are available pre-cut to customersrequirements.
TypeTypeCat. no.Type/colourCat. no.FeaturesMaterialProcessing
Rails / protective earth / busbars according to DIN VDE 0611, part 3
TypeTS 32TS 32 slottedTS 35 x 7.5TS 35 x 7.5 slottedTS 35 x 7.5TS 35 x 7.5TS 35 x 7.5 slottedTS 35 x 7.5TS 35 x 15TS 35 x 15TS 35 x 15 slottedTS 35 x 15 slottedTS 35 x 15/2.3TS 35 x 15/2.3, slottedTS 15TS 15 slottedTS 15TS 15 slotted
Cat. no.2025.02093.02026.02094.02704.04562.04563.02710.02027.04561.02095.04566.02038.02039.02091.02092.02711.02378.0
MaterialSteel SteelSteelSteelSteelGalvanized steelGalvanized steelAluminiumSteelGalvanized steelSteelSteelSteelSteelSteelSteelAluminiumAluminium
Short-circuitresistance
353516161616163525252525505010101616
Max. short-circuit currentKA4.24.21.921.921.921.921.924.23.03.03.03.06.06.01.21.2
1.921.92
Max. allowed thermal rated current, with PEN function
*******
105********
8182
* Use of protective earth steel busbars is not permitted for PEN functionality!
271
Notes
GEN
ERA
L A
CC
ESSO
RIE
S
CONTA-CONNECT
272
CONTA-CONNECT
DIN rails TS | DIN rail brackets TSTW/TST
DIN rails TS 15
The design of the TS DIN rail complies with the European normDIN EN 60715. The steel DIN rail is galvanized and has a coatingof blue chromate that is at least 10 µm thick. We place extraimportance on maintaining a high degree of dimensional accura-cy. The steel DIN rails can be used as protective-earth busbars(with PE function) in compliance with DIN VDE 0611 part 3.Please note the following when using the rail as a PEN busbar:
• Only one E-Cu rail should be used.• The short-circuit currents and the rated thermal currents
must be observed.
The DIN rails are delivered in standard lengths of 2 meters.All DIN rails are also available in prepared (cut to length)versions, but all types are available pre-cut to customersrequirements.
TypeTypeCat. no.Type/colourCat. no.FeaturesMaterialProcessing
DIN rail brackets TSTW/TST
TypeTypeCat. no.Type/colourCat. no.FeaturesMaterialDrill holeHeight, mm
AccessoriesScrewCat. no.
TS 15
TS 15 unslotted2091.0
Steelunslotted
TS 15
TS 15 slotted2092.0
Steelslotted 4.2 x 12
TS 15
TS 15 ALU unslotted2711.0
Aluminiumunslotted
Qty.
2m
Qty.
2m
Qty.
2m
Qty.
10
Qty.
10
Qty.
10
Qty.
50
Qty.
50
Qty.
50
new photo 2563.0please colour in
TSTW/F/M6
DIN rail bracket M6
TSTW/F/M62563.0
SteelM 632
BS M 6x12/152304.0
TSTW/M6
DIN rail bracket M5
TSTW/M62414.0
SteelM 548
BS M 5x8/152415.0
TSTW/M6
DIN rail bracket M6
TSTW/M62303.0
SteelM 648
BS M 6x12/152304.0
272
Qty.
2m
Qty.
10
Qty.
50
Qty.
10
Qty.
50
Qty.
10
Qty.
50
TS 15
TS 15 ALU slotted2378.0
Aluminiumslotted 4.2 x 12
TST/M5
DIN rail bracket M5
TST/M52736.0
SteelM 520
BS M 5x8/152415.0
TST/M6
DIN rail bracket M6
TST/M62737.0
SteelM 620
BS M 6x12/152304.0
TSTW/F/M5
DIN rail bracket M5
TSTW/F/M52564.0
SteelM 532
BS M 5x8/152415.0
273
GEN
ERA
L A
CC
ESSO
RIE
S
CONTA-CONNECTCONTA-CONNECT
End stops | End supports
Qty.
50
Qty.
50
Qty.
50
Qty.
50
Qty.
50
Qty.
50
Qty.
50
Qty.
50
Qty.
50
End stops TS 35
End stops are necessary for preventing movement of com-ponents along the rail. They are put in at the beginningand at the end of the rail assembly. Depending on theDIN rail, they differ in the dimensions of the mountingfoot and their screw-on or snap-on design.
DimensionsDimensions (LxWxH), mmTypeTypeCat. no.FeaturesMaterialDIN railsTerminal width, mm
End stops TS 32
DimensionsDimensions (LxWxH), mmTypeTypeCat. no.FeaturesMaterialDIN railsTerminal width, mm
End support for BKA / KBL
DimensionsDimensions (LxWxH), mmTypeTypeCat. no.FeaturesMaterialMountingTerminal width, mmHole diameter, mmFor terminal
ES 35
46 x 7.5 x 32
ES 35 BG2005.2
PA 6.6 V2TS 35
7.5
ES 35/2/K
50 x 8 x 47
ES 35/2/K BG2826.2
PA 6.6 V2TS 35
8
ES 35/K/ST
50 x 9.5 x 44
ES 35/K/ST BG2828.0
PA 6.6 V2TS 35
9,5
ES 32
27 x 7.5 x 44
ES 32 BG2004.2
PA 6.6 V2TS 32
7.5
ES 32/2/K
48 x 8 x 49
ES 32/2/K BG2825.2
PA 6.6 V2TS 32
8
ES 32/2K/ST
50 x 9,5 x 44
ES 32/K/ST BG2827.0
PA 6.6 V2TS 32
9.5
EH 1
22 x 7 x 21
EH 1 BG2135.2
PA 6.6 V2Direct mounting
73.5
RKB 4
EH 2
22 x 7 x 23
EH 2 BG2136.2
PA 6.6 V2Direct mounting
73.5
BKA 2,5BKA 4
EH 2-Z
22 x 5 x 23
EH 2-Z BG2147.2
PA 6.6 V2Direct mounting
5-
BKA 2,5BKA 4
Screw end stop Screw end stop Screw end stop
Screw end stop Screw end stop Screw end stop
Screw end support Screw end support screwlessEnd support
274
Qty.
50
Qty.
50
Qty.
50
Qty.
50
Qty.
50
Qty.
50
Qty.
50
Qty.
50
Qty.
50
Qty.
50
Qty.
50
Qty.
50
End stops TS 15
Dimensions (L x W x H), mmTypeTypeCat. no.FeaturesMaterialDIN railsTerminal width, mm
ES 32/35
52 x 9.5 x 47
ES 32/35 BG1424.2
PA 6.6 V2TS 35 / TS 32
9,5
HES 35 ST
49 x 11 x 69
HES 35/ST BG2761.0
SteelTS 35
11
ZES 35
59 x 6 x 39
ZES 35 BG3748.2
PA 6.6 V2TS 35
6
ZES 35/2
49 x 5 x 34
ZES 35/2 BG3811.2
PA 6.6 V2TS 35
5
ES 32/35
52 x 9,5 x 47
ES 32/35 BG1424.2
PA 6.6 V2TS 35 / TS 32
9,5
HES 32 ST
49 x 11 x 69
HES 32/ST BG2760.0
SteelTS 32
11
ES 15
26 x 7.5 x 22
ES 15 BG2074.2
PA 6.6 V2TS 15
7.5
ZES 15
27 x 5 x 24
ZES 15 BG3812.2
PA 6.6 V2TS 15
5
EH 3
30 x 8 x 31
ES 3 BG2939.2
PA 6.6 V2Direct mounting
83.5
BKA 10
EH 4
46 x 8 x 36
EH 4 BG2180.2
PA 6.6 V2Direct mounting
83.5
KBL 2,5DKBL 2,5-4DKBL 6-10D
EH 15 BKA
31 x 9 x 28
EH 15 BKA BG2945.2
PA 6.6 V2TS 15
9-
BKA 2,5BKA 4
EH 35 BKA
46 x 8 x 39
EH 35 BKA BG2946.2
PA 6.6 V2TS 35
8-
BKA 10
ZEH 1
40 x 11,1 x 24
ZEH 1 BG3759.2
PA 6.6 V0Direct mounting
11.13.5
ZSRK...ZSLN...
Screw end stop Screw end stop Screwless end stop Screwless end stop
Screw end stop Screw end stop Screw end stop Screwless end stop
Screw end support Screw end support Screw end support Screw end support Screw end support
275
GEN
ERA
L A
CC
ESSO
RIE
S
Marker holders for terminal blocks and end stopsCONTA-CONNECT
Marker holders for terminal blocks and end stops
These marker holders provide a solution for marking agroup of terminals or devices on the DIN rail.
The marker holders are available for attaching to terminalblocks and end stops. The GT1 and GT2 group marker holders can be attacheddirectly to the DIN rail. Depending on the type, they canbe be marked with SB and AS terminal markers.Custom marking is possible with BS-1 pen or EMS-2 plotter.
Material: Polyamide 6.6 V2, halogen-free
TypeType/colourCat. no.Type/colourCat. no.Colours available
CharacteristicsDimensionsWidth, mmMaterialMaterial Temperature rangeFlamm. class acc. to UL 94ApplicationTerminal blocksEnd stopAccessoriesTerminal marker PMCCat. no.Terminal marker MCCat. no.Terminal marker AS3Cat. no.Insert marker Cat. no.Adhesive device labels GKECat. no.Protective stripsCat. no.Shield cap SKCat. no.
SchT 4/8 - SchT 6/12
Hinged marker holder for terminal block
and end stop
SchT 4/8 *1
2528.0SchT 6/12 *2
2529.0
5
PA6.6, halogen-free-40 °C to +105°C
V2
≥ 5 mmAll types
PMC SB 5/50 WH4600.7MC SB 5/2003300.7AS 3/10 WH2571.0
SchT 9
Marker holders for end stops
SchT 93749.0
8
PA6.6, halogen-free-40°C to +105°C
V2
EMS-2CCI-11BS-1
-ES../2/K | ES../K/ST
Page
339
356
354
Qty.
500
1000
500
Page Qty.
Qty.
100
100
Qty.
100
SchT 7
Hinged marker holder for terminal block
and end stop
SchT 7, short joint2504.0SchT 7, long joint2361.0
8.5
PA6.6, halogen-free-40 °C to +105°C
V2
≥ 5 mmAll types
ESO 2584.0GKE 30/6 WH3917.7STR 12506.0
SchT 10
Marker holders for end stops
SchT 103809.0
9,5
PA6.6, halogen-free-40°C to +105°C
V2
EMS-2CCI-11BS-1
-ES../K/ST
Page Qty.
Qty.
100
100
Qty.
100
ZSchT1
Hinged marker holder for terminal block and end stop
ZSchT 13773.0
8.5
PA6.6, halogen-free-40°C to +105°C
V2
≥ 5 mmAll types
ESO 2584.0GKE 30/6 WH3917.7STR 12506.0
ZSchT 3
Hinged marker holder for endstop
ZSchT 33775.2
8,5
PA6.6, halogen-free-40°C to +105°C
V2
-ES/.. | ZES 35
ESO 2584.0GKE 30/6 WH3917.7STR 12506.0
Page
404
Qty.1 sheet of
120 pieces1 roll of 10000
pieces
100
Qty.
100
100
Qty.
100
TypeType/colourCat. no.Type/colourCat. no.Colours available
CharacteristicsDimensionsWidth, mmMaterialMaterial Temperature rangeFlamm. class acc. to UL 94InscriptionPlotterPlotter inlayMarker penApplicationTerminal blocksEnd stopAccessoriesInsert marker Cat. no.Adhesive device labels GKECat. no.Protective stripsCat. no.
Page
398
Qty.
1 sheet of 120pieces
1 roll of 10000pieces
100
Qty.
1 sheet of 120pieces
1 roll of 10000pieces
100
Page
398
*1: 4 x SB or 8 x AS markers*2: 6 x SB or 12 x AS markers276
.2 .2 .2
.0 .0 .2
More accessories starting on page 264.
277
ZSchT2
Hinged marker holder for terminal block and end stop
ZSchT 23774.0
8,5
PA6.6, halogen-free-40°C to +105°C
V2
≥ 5 mmAll types
ESO 2584.0GKE 30/6 WH3917.7STR 12506.0
ZSchT 4
Hinged marker holder for end stop
ZSchT 43776.0
8.5
PA6.6, halogen-free-40°C to +105°C
V2
-ES/.. | ZES 35
ESO 2584.0GKE 30/6 WH3917.7STR 12506.0
Page
404
Qty.1 sheet of 120
pieces1 roll of 10000
pieces
100
Qty.
100
Qty.
100
Qty.
1 sheet of 120pieces
1 roll of 10000pieces
100
Page
398
ZSchT 5
Hinged marker holder for end stop
ZSchT 53777.0
6
PA6.6, halogen-free-40°C to +105°C
V2
-ES../2/K | ES../K/ST | ZES35
ESO 32585.0
STR 32579.0
Page Qty.1 sheet of
124 pieces
100
Qty.
100
SchT 12
Marker holder for terminal block
SchT 12*1
2531.0
6
PA6.6, halogen-free-40°C to +105°C
V2
RK2,5-4 | RK6-10-
PMC SB 5/50 WH4600.7MC SB 5/2003300.7AS 3/10 WH2571.0
ZSchT 6
Marker holders for end stops
ZSchT 63807.0
6
PA6.6, halogen-free-40°C to +105°C
V2
EMS-2CCI-11BS-1
-ES../2/K | ES../K/ST | ZES35
Page Qty.
Qty.
100
Qty.
100
Qty.
500
1000
500
Page
339
356
354
SchT 2
Marker holders for end stops
SchT 22888.0
9,5
PA6.6, halogen-free-40°C to + 105°C
V2
-ES../2/K | ES../K/ST
ESO 22877.0GKE 30/6 WH3917.7
STR 22878.0
GT 1
Group marker holder for TS35/32 DIN rail
GT 13783.2
9.5
PA6.6, halogen-free-40°C to +105°C
V2
--
ESO GT 12580.0GKE 30/6 WH3917.7STR GT 12582.0
Page
404
Qty.1 sheet of 140
pieces1 roll of 10000
pieces
20
Qty.
100
Qty.
20
Qty.
101 roll of 10000
pieces
100
Page
398
SchT 11
Marker holders for end stops
SchT 11*1
2530.0
5
PA6.6, halogen-free-40°C to +105°C
V2
-ES../2/K | ES../K/ST | ZES35/2
PMC SB 5/50 WH4600.7MC SB 5/2003300.7AS 3/10 WH2571.0
GT 2
Group marker holder for TS35/32 DIN rail
GT 23784.2
19.5
PA6.6, halogen-free-40°C to +105°C
V2
--
ESO GT 22581.0GKE 30/6 WH3917.7STR GT 22583.0
Page
404
Qty.1 sheet of 60 pieces
1 roll of 10000pieces
20
Qty.
100
Qty.
20
Qty.
500
1000
500
Page
339
356
354
277
.2 .2 .2 .0
.2 .2 .2.0
GEN
ERA
L A
CC
ESSO
RIE
S
CONTA-CONNECT
Specific accessories, pressure-spring connection system (FRK)
End plates / Visual separation
TypeAP 2,5/15 BG AP 2,5/15 BUAP 2,5/15 OG AP 2,5/15 GN AP 2,5/15 RD AP 2,5/15 YE
AP-SR BGAP-SR BU AP-SR OG AP-SR GN AP-SR RD AP-SR YE
AP 1,5-4 BG AP 1,5-4 BU AP 1,5-4 OG AP 1,5-4 GN AP 1,5-4 RD AP 1,5-4 YE
AP 2,5-10 BG
AP 2,5-10 BU
AP 2,5-10 OG
AP 2,5-10 GN
AP 2,5-10 RD
AP 2,5-10 YE
AP 16 BG AP 16 BU AP 16 OG AP 35 BG AP 35 BU AP 35 OG
AP/FF 1/15 BG AP 2,5/R BG AP 2,5/R BU AP 2,5/R GN AP 2,5/RL BG AP 2,5/RL BU AP 2,5/RL GN AP/L/Q/D BG
Cat. no..2427.2 2427.5 2427.3 2427.1 2427.9 2427.8 2070.2 2070.5 2070.3 2070.1 2070.9 2070.8 2738.2 2738.5 2738.3 2738.1 2738.9 2738.8 2001.2
2001.5
2001.3
2001.1
2001.9
2001.8
2104.2 2104.5 2104.3 2116.2 2116.5 2116.32421.2 2574.2 2574.5 2574.1 2575.2 2575.5 2575.1 2782.2
Colourbeige blue
orangegreen
red yellow beige blue
orangegreen
red yellow beige blue
orangegreen
red yellow beige
blue
orange
green
red
yellow
beige blue
orange beige blue
orange beigebeige blue
green beige blue
green beige
Qty.50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50
50
50
50
50
50
20 20 20 20 20 20 20 50 50 50 50 50 50 20
For terminalSRK 2,5/15 SRK 2,5/15 SRK 2,5/15 SRK 2,5/15 SRK 2,5/15 SRK 2,5/15
SRK 2,5 SRK 2,5 SRK 2,5 SRK 2,5 SRK 2,5 SRK 2,5
RK 1,5-4/15 | RK 1,5-4 RK 1,5-4/15 | RK 1,5-4 RK 1,5-4/15 | RK 1,5-4 RK 1,5-4/15 | RK 1,5-4 RK 1,5-4/15 | RK 1,5-4 RK 1,5-4/15 | RK 1,5-4 SRK 2,5/2A-SRK 10/2A
RK 2,5-4 | RK 6-10, TSK, FF, SF SRK 2,5/2A-SRK 10/2A
RK 2,5-4 | RK 6-10, TSK, FF, SF SRK 2,5/2A-SRK 10/2A
RK 2,5-4 | RK 6-10, TSK, FF, SF SRK 2,5/2A-SRK 10/2A
RK 2,5-4 | RK 6-10, TSK, FF, SF SRK 2,5/2A-SRK 10/2A
RK 2,5-4 | RK 6-10, TSK, FF, SF SRK 2,5/2A-SRK 10/2A
RK 2,5-4 | RK 6-10, TSK, FF, SF RK 16 RK 16 RK 16 RK 35 RK 35 RK 35 FF 1,5
RK 2,5-4 ZR RK 2,5-4 ZR RK 2,5-4 ZR RK 2,5-4 ZRL RK 2,5-4 ZRL RK 2,5-4 ZRL
PTK
Width1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm
1.5 mm
1.5 mm
1.5 mm
1.5 mm
1.5 mm
1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm
MaterialPA 6.6 V2 PA 6.6 V2 PA 6.6 V2 PA 6.6 V2 PA 6.6 V2 PA 6.6 V2 PA 6.6 V2 PA 6.6 V2 PA 6.6 V2 PA 6.6 V2 PA 6.6 V2 PA 6.6 V2 PA 6.6 V2 PA 6.6 V2 PA 6.6 V2 PA 6.6 V2 PA 6.6 V2 PA 6.6 V2 PA 6.6 V2
PA 6.6 V2
PA 6.6 V2
PA 6.6 V2
PA 6.6 V2
PA 6.6 V2
PA 6.6 V2 PA 6.6 V2 PA 6.6 V2 PA 6.6 V2 PA 6.6 V2 PA 6.6 V2 PA 6.6 V2 PA 6.6 V2 PA 6.6 V2 PA 6.6 V2 PA 6.6 V2 PA 6.6 V2 PA 6.6 V2 PA 6.6 V2
End plates | Visual separation
Screw connection system
The AP end plates are normally used at the endof a row of terminals. If different terminals arebeing used within the same terminal block, thenyou should insert end plates in order to ensurethat the touch-safe protection is maintained. Theouter dimensions of the end plates match thedimensions of the terminals.
Coloured end plates are used quite often inorder to establish a clear visual separationbetween the different circuits or voltage levels.In addition, the use of end plates increases theclearance and creepage distances, which in turninfluence the voltage ratings.
The locking pegs ensure that the end plates canbe mounted quickly.
Because of the special design of the RK series,an end plate does not need to be used to sepa-rate neighbouring QI cross-connectors of differ-ent potentials.
End plates for standard terminals SRK|RK|TSK|FF|SS|SF|PTK
TypeAP 4 BG AP 4 BU AP 4 OG AP 4 GN AP 4 RD AP 4 YE
AP 4 800 V BG APG 4 BG APG 4 BU
Cat. no..2101.2 2101.5 2101.3 2101.1 2101.9 2101.8 2159.22586.2 2586.5
Colourbeigeblue
orangegreen
redyellowbeigebeigeblue
Qty.202020202020202020
For terminalRKD 2,5 | RKD 4 RKD 2,5 | RKD 4 RKD 2,5 | RKD 4 RKD 2,5 | RKD 4 RKD 2,5 | RKD 4
RKD 4 RKD 4
RKDG 4 RKDG 4
Width1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm
MaterialPA 6.6 V2 PA 6.6 V2 PA 6.6 V2 PA 6.6 V2 PA 6.6 V2 PA 6.6 V2 PA 6.6 V2PA 6.6 V2PA 6.6 V2
End plates for double-level terminal blocks RKD | RKDG
TypeAP 2,5/ID BG AP 2,5/ID BU AP 2,5/ID OG
AP VMAK 2,5 BG AP VMAK 2,5 BU AP VMAK 2,5 OG
AP 2,5/I BG AP 2,5/I BU AP 2,5/I OG
AP/IKD 2,5/short BGAP 2,5 S BG AP 2,5 D BG
Cat. no.2699.2 2699.5 2699.3 2862.2 2862.5 2862.3 2698.2 2698.5 2698.32714.2 2829.22831.2
Colourbeigeblue
orangebeigeblue
orangebeigeblue
orangebeigebeigebeige
Qty.202020202020202020202020
For terminalIKD 2,5 IKD 2,5 IKD 2,5
VMAK 2,5 VMAK 2,5 VMAK 2,5
IK 2,5 IK 2,5 IK 2,5
IKD 2,5 DLIS 2,5 DLI 2,5
Width1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm
MaterialPA 6.6 V2 PA 6.6 V2 PA 6.6 V2 PA 6.6 V2 PA 6.6 V2 PA 6.6 V2 PA 6.6 V2PA 6.6 V2PA 6.6 V2PA 6.6 V2PA 6.6 V2PA 6.6 V2
End plates for multi-level terminal blocks IKD|VMAK|IK|DLIS|DLI
TypeAP/SI-1 BG AP/SI-1 OG AP/SI-1 BUAP/SI BG AP/SI BK
AP/SI-2 BG AP/SI-2 OG AP/SI-2 BU
AP/SID-1 BG AP/SID-1 OG AP/SID-1 BU
AP 10 BG AP 10 OG AP 10 BG
Cat. no..2046.2 2046.3 2046.52047.2 2047.42186.2 2186.3 2186.5 2187.2 2187.3 2187.5 2762.2 2762.3 2762.5
Colourbeige
orange blue
beige black beige
orange blue beige
orange blue beige
orange blue
Qty.50 50 50 5020 50 50 50 20 20 20 20 20 20
For terminalSTK 1 | TK 2
STK 1 | TK 2 STK 1 | TK 2
SK 1 SK 1
STK 2 | STK 2/K STK 2 | STK 2/K STK 2 | STK 2/K
STKD 1 | STKD 1/K STKD 1 | STKD 1/K STKD 1 | STKD 1/K
SIK 10 SIK 10 SIK 10
Width1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm
2 mm 2 mm 2 mm
MaterialPA 6.6 V2 PA 6.6 V2 PA 6.6 V2 PA 6.6 V2 PA 6.6 V2 PA 6.6 V2 PA 6.6 V2 PA 6.6 V2PA 6.6 V2PA 6.6 V2PA 6.6 V2PA 6.6 V2PA 6.6 V2PA 6.6 V2
End plates for Disconnect- and fused terminals STK|TK|STKD|SIK|SK
278
Specific accessories, pressure-spring connection system (FRK)
End plates / Visual separation
TypeFAP 1,5-4/2A BG
FAP 1,5-4/2A BU
FAP 1,5-4/2A OG
FAP 1,5-4/2A GN
FAP 1,5-4/2A RD
FAP 1,5-4/2A YE
FAP 1,5/3A BGFAP 1,5/3A BUFAP 1,5/3A OGFAP 1,5/3A GNFAP 1,5/3A RDFAP 1,5/3A YEFAP 1,5/4A BGFAP 1,5/4A BUFAP 1,5/4A OGFAP 1,5/4A GNFAP 1,5/4A RDFAP 1,5/4A YEFAP 2,5/3A BGFAP 2,5/3A BUFAP 2,5/3A OGFAP 2,5/3A GNFAP 2,5/3A RDFAP 2,5/3A YEFAP 2,5/4A BGFAP 2,5/4A BUFAP 2,5/4A OGFAP 2,5/4A GNFAP 2,5/4A RDFAP 2,5/4A YEFAP 4/3A BGFAP 4/3A BUFAP 4/3A OGFAP 4/3A GNFAP 4/3A RDFAP 4/3A YEFAP 4/4A BGFAP 4/4A BUFAP 4/4A OGFAP 4/4A GNFAP 4/4A RDFAP 4/4A YE
Cat. no..3400.2
3400.5
3400.3
3400.1
3400.9
3400.8
3401.23401.53401.33401.13401.93401.83402.23402.53402.33402.13402.93402.83411.23411.53411.33411.13411.93411.83412.23412.53412.33412.13412.93412.83421.23421.53421.33421.13421.93421.83422.23422.53422.33422.13422.93422.8
Colourbeige
blue
orangegreen
red
yellow
beigeblue
orangegreen
redyellowbeigeblue
orangegreen
redyellowbeigeblue
orangegreen
redyellowbeigeblue
orangegreen
redyellowbeigeblue
orangegreen
redyellowbeigeblue
orangegreen
redyellow
Qty.20
20
20
20
20
20
202020202020202020202020202020202020202020202020202020202020202020202020
For terminalFRK 1,5/2A, FSL 1,5/2AFRK 2,5/2A, FSL 2,5/2A
FRK 4/2A, FSL 4/2AFRK 1,5/2A, FSL 1,5/2AFRK 2,5/2A, FSL 2,5/2A
FRK 4/2A, FSL 4/2AFRK 1,5/2A, FSL 1,5/2AFRK 2,5/2A, FSL 2,5/2A
FRK 4/2A, FSL 4/2AFRK 1,5/2A, FSL 1,5/2AFRK 2,5/2A, FSL 2,5/2A
FRK 4/2A, FSL 4/2AFRK 1,5/2A, FSL 1,5/2AFRK 2,5/2A, FSL 2,5/2A
FRK 4/2A, FSL 4/2AFRK 1,5/2A, FSL 1,5/2AFRK 2,5/2A, FSL 2,5/2A
FRK 4/2A, FSL 4/2AFRK 1,5/3A, FSL 1,5/3A FRK 1,5/3A, FSL 1,5/3AFRK 1,5/3A, FSL 1,5/3AFRK 1,5/2A, FSL 1,5/3AFRK 1,5/3A, FSL 1,5/3AFRK 1,5/2A, FSL 1,5/3AFRK 1,5/4A, FSL 1,5/4AFRK 1,5/4A, FSL 1,5/4AFRK 1,5/4A, FSL 1,5/4AFRK 1,5/2A, FSL 1,5/4AFRK 1,5/4A, FSL 1,5/4AFRK 1,5/2A, FSL 1,5/4AFRK 2,5/3A, FSL 2,5/3A FRK 2,5/3A, FSL 2,5/3AFRK 2,5/3A, FSL 2,5/3AFRK 2,5/3A, FSL 2,5/3AFRK 2,5/3A, FSL 2,5/3AFRK 2,5/3A, FSL 2,5/3AFRK 2,5/4A, FSL 2,5/4AFRK 2,5/4A, FSL 2,5/4AFRK 2,5/4A, FSL 2,5/4AFRK 2,5/4A, FSL 2,5/4AFRK 2,5/4A, FSL 2,5/4AFRK 2,5/4A, FSL 2,5/4A
FRK 4/3A, FSL 4/3A FRK 4/3A, FSL 4/3AFRK 4/3A, FSL 4/3AFRK 4/3A, FSL 4/3AFRK 4/3A, FSL 4/3AFRK 4/3A, FSL 4/3AFRK 4/4A, FSL 4/4AFRK 4/4A, FSL 4/4AFRK 4/4A, FSL 4/4AFRK 4/4A, FSL 4/4AFRK 4/4A, FSL 4/4AFRK 4/4A, FSL 4/4A
Width1.5 mm
1.5 mm
1.5 mm
1.5 mm
1.5 mm
1.5 mm
1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm
MaterialPA 6.6 V0
PA 6.6 V0
PA 6.6 V0
PA 6.6 V0
PA 6.6 V0
PA 6.6 V0
PA 6.6 V0PA 6.6 V0PA 6.6 V0PA 6.6 V0PA 6.6 V0PA 6.6 V0PA 6.6 V0PA 6.6 V0PA 6.6 V0PA 6.6 V0PA 6.6 V0PA 6.6 V0PA 6.6 V0PA 6.6 V0PA 6.6 V0PA 6.6 V0PA 6.6 V0PA 6.6 V0PA 6.6 V0PA 6.6 V0PA 6.6 V0PA 6.6 V0PA 6.6 V0PA 6.6 V0PA 6.6 V0PA 6.6 V0PA 6.6 V0PA 6.6 V0PA 6.6 V0PA 6.6 V0PA 6.6 V0PA 6.6 V0PA 6.6 V0PA 6.6 V0PA 6.6 V0PA 6.6 V0
End plates | Visual separation
Pressure-spring connection system
The FAP end plates are normally used at theend of a row of terminals. If different terminalsare being used within the same terminal block,then you should insert end plates in order toensure that the touch-safe protection is main-tained.The outer dimensions of the end plates matchthe dimensions of the terminal blocks.
Coloured end plates are often used to establish aclear visual separation between the different cir-cuits or voltage levels.In addition, the use of end plates increases theclearance and creepage distances, which in turninfluence the voltage ratings.
The locking pegs ensure that the end plates canbe mounted quickly.
Because of the special design of the FRK series,an end plate does not need to be used to sepa-rate neighbouring cross-connectors of differentpotentials.
End plates for double-level terminal blocks FRK
TypeFAPD 2,5 BG FAPD 2,5 BU FAPD 2,5 OG FAPD 2,5 GN
Cat. no..3423.2 3423.5 3423.3 3423.1
Colourbeige blue
orange green
Qty.20202020
For terminalFRKD 2,5 | FSLD 2,5 FRKD 2,5 | FSLD 2,5 FRKD 2,5 | FSLD 2,5 FRKD 2,5 | FSLD 2,5
Width1.5 mm1.5 mm1.5 mm1.5 mm
MaterialPA 6.6 V0PA 6.6 V0PA 6.6 V0PA 6.6 V0
End plates for double-level terminals FRKD
TypeFAPT 2,5/2A BG FAPT 2,5/2A BU FAPT 2,5/2A OG FAPT 2,5/2A GN FAPT 2,5/2A RD FAPT 2,5/2A YE FAPT 2,5/3A BG FAPT 2,5/3A BU FAPT 2,5/3A OG FAPT 2,5/3A GN FAPT 2,5/3A RD FAPT 2,5/3A YE
Cat. no.3481.2 3481.5 3481.3 3481.1 3481.9 3481.8 3482.2 3482.5 3482.3 3482.1 3482.9 3482.8
Colourbeige blue
orangegreen
red yellow beige blue
orangegreen
red yellow
Qty.202020202020202020202020
For terminalFTRK 2,5/2A FTRK 2,5/2A FTRK 2,5/2A FTRK 2,5/2A FTRK 2,5/2A FTRK 2,5/2A FTRK 2,5/3A FTRK 2,5/3A FTRK 2,5/3A FTRK 2,5/3A FTRK 2,5/3A FTRK 2,5/3A
Width1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm1.5 mm
MaterialPA 6.6 V0PA 6.6 V0PA 6.6 V0PA 6.6 V0PA 6.6 V0PA 6.6 V0PA 6.6 V0PA 6.6 V0PA 6.6 V0PA 6.6 V0PA 6.6 V0PA 6.6 V0
End plates for disconnect and fused terminals FTRK
TypeFAP 4/S BG FAP 4/S BU FAP 4/S OG
Cat. no..3480.2 3480.5 3480.3
Colourbeige blue
orange
Qty.202020
For terminalFDLIS 2,5-4.... FDLIS 2,5-4.... FDLIS 2,5-4....
Width1.5 mm1.5 mm1.5 mm
MaterialPA 6.6 V0PA 6.6 V0PA 6.6 V0
End plates for multi-level terminals FDLIS
279
GEN
ERA
L A
CC
ESSO
RIE
S
CONTA-CONNECT
Specific accessories, pressure-spring connection system (FRK)
End plates / Visual separation
TypeZAP 2,5/2A BG ZAP 2,5/2A BU ZAP 2,5/2A OG ZAP 2,5/2A GN ZAP 2,5/2A RD ZAP 2,5/2A YE ZAP 2,5/3A BG ZAP 2,5/3A BU ZAP 2,5/3A OG ZAP 2,5/3A GN ZAP 2,5/3A RD ZAP 2,5/3A YE ZAP 2,5/4A BG ZAP 2,5/4A BU ZAP 2,5/4A OG ZAP 2,5/4A GN ZAP 2,5/4A YE ZAP 2,5/4A RD ZAP 4/2A BG ZAP 4/2A BU ZAP 4/2A OG ZAP 4/2A GN ZAP 4/2A RD ZAP 4/2A YE ZAP 4/3A BG ZAP 4/3A BU ZAP 4/3A OG ZAP 4/3A GN ZAP 4/3A RD ZAP 4/3A YE ZAP 4/4A BG ZAP 4/4A BU ZAP 4/4A OG ZAP 4/4A GN ZAP 4/4A RD ZAP 4/4A YE
Cat. no..3700.2 3700.5 3700.3 3700.1 3700.9 3700.8 3701.2 3701.5 3701.3 3701.1 3701.9 3701.8 3702.2 3702.5 3702.3 3702.1 3702.8 3702.9 3703.2 3703.5 3703.3 3703.1 3703.9 3703.8 3704.2 3704.5 3704.3 3704.1 3704.9 3704.8 3705.2 3705.5 3705.3 3705.1 3705.9 3705.8
Colourbeige blue
orange green
red yellow beige blue
orange green
red yellow beige blue
orange green yellow
red beige blue
orange green
red yellow beige blue
orange green
red yellow beige blue
orange green
red yellow
Qty.50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 5050 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50
For terminalZRK 2,5/2A | ZSL 2,5/2A ZRK 2,5/2A | ZSL 2,5/2A ZRK 2,5/2A | ZSL 2,5/2A ZRK 2,5/2A | ZSL 2,5/2A ZRK 2,5/2A | ZSL 2,5/2A ZRK 2,5/2A | ZSL 2,5/2A ZRK 2,5/3A | ZSL 2,5/3A ZRK 2,5/3A | ZSL 2,5/3A ZRK 2,5/3A | ZSL 2,5/3A ZRK 2,5/3A | ZSL 2,5/3A ZRK 2,5/3A | ZSL 2,5/3A ZRK 2,5/3A | ZSL 2,5/3A ZRK 2,5/4A | ZSL 2,5/4A ZRK 2,5/4A | ZSL 2,5/4A ZRK 2,5/4A | ZSL 2,5/4A ZRK 2,5/4A | ZSL 2,5/4A ZRK 2,5/4A | ZSL 2,5/4A ZRK 2,5/4A | ZSL 2,5/4A
ZRK 4/2A | ZSL 4/2A ZRK 4/2A | ZSL 4/2A ZRK 4/2A | ZSL 4/2A ZRK 4/2A | ZSL 4/2A ZRK 4/2A | ZSL 4/2A ZRK 4/2A | ZSL 4/2A ZRK 4/3A | ZSL 4/3A ZRK 4/3A | ZSL 4/3A ZRK 4/3A | ZSL 4/3A ZRK 4/3A | ZSL 4/3A ZRK 4/3A | ZSL 4/3A ZRK 4/3A | ZSL 4/3A ZRK 4/4A | ZSL 4/4A ZRK 4/4A | ZSL 4/4A ZRK 4/4A | ZSL 4/4A ZRK 4/4A | ZSL 4/4A ZRK 4/4A | ZSL 4/4A ZRK 4/4A | ZSL 4/4A
Width2 mm 2 mm 2 mm 2 mm 2 mm 2 mm 2 mm 2 mm 2 mm 2 mm 2 mm 2 mm 2 mm 2 mm 2 mm 2 mm 2 mm 2 mm 2 mm 2 mm 2 mm 2 mm 2 mm 2 mm 2 mm 2 mm 2 mm 2 mm 2 mm 2 mm 2 mm 2 mm 2 mm 2 mm 2 mm 2 mm
MaterialPA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0
End plates | Visual separation
Tension-spring connection system
The ZAP end plates are normally used at theend of a row of terminals. End plates must alsobe used within a terminal strip when it makesuse of terminal blocks of different sizes in orderto ensure touch-safe finger protection. The outerdimensions of the end plates match the dimen-sions of the terminal blocks.
Coloured end plates are used quite often inorder to establish a clear visual separationbetween the different circuits or voltage levels.In addition, the use of end plates increases theclearance and creepage distances, which in turninfluence the voltage ratings. The locking pegsensure that the end plates can be mountedquickly.
Because of the special design of the ZRK series,an end plate does not need to be used to sepa-rate neighbouring cross-connectors of differentpotentials.
End plates for standard terminal blocks ZRK/ZSL
TypeZAP SR/RC BG ZAP SR/RC BU ZAP SR/RC OG ZAP SR/RC GN ZAP SR/RC RD ZAP SR/RC YE
Cat. no..3758.2 3758.5 3758.3 3758.1 3758.9 3758.8
Colourbeige blue
orange green
red yellow
Qty.50 50 50 50 50 50
For terminalZSRK 2,5/2A/RC | ZSLN 2,5/2A/RC ZSRK 2,5/2A/RC | ZSLN 2,5/2A/RC ZSRK 2,5/2A/RC | ZSLN 2,5/2A/RC ZSRK 2,5/2A/RC | ZSLN 2,5/2A/RC ZSRK 2,5/2A/RC | ZSLN 2,5/2A/RC ZSRK 2,5/2A/RC | ZSLN 2,5/2A/RC
Width5 mm 5 mm 5 mm 5 mm 5 mm 5 mm
MaterialPA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0
End plates for direct-mount terminal blocks with snap-in clip ZSRK/ZSLN (RC)
TypeZAP SR BG ZAP SR BU ZAP SR OG ZAP SR GN ZAP SR RD ZAP SR YE
ZAP SR 3A/15 BG ZAP SR 3A/15 BU ZAP SR 3A/15 OG ZAP SR 3A/15 GN ZAP SR 3A/15 RD ZAP SR 3A/15 YE ZAP SR 3A/35 BG ZAP SR 3A/35 BU ZAP SR 3A/35 OG ZAP SR 3A/35 GN ZAP SR 3A/35 RD ZAP SR 3A/35 YE
Cat. no..3757.2 3757.5 3757.3 3757.1 3757.9 3757.8 3794.2 3794.5 3794.3 3794.1 3794.9 3794.8 3795.2 3795.5 3795.3 3795.1 3795.9 3795.8
Colourbeige blue
orange green
red yellow beige blue
orangegreen
red yellow beige blue
orange green
red yellow
Qty.50 50 50 50 50 5050 50 50 50 50 5050 50 50 50 50 50
For terminalZSRK 2,5/2A | ZSLN 2,5/2A ZSRK 2,5/2A | ZSLN 2,5/2A ZSRK 2,5/2A | ZSLN 2,5/2A ZSRK 2,5/2A | ZSLN 2,5/2A ZSRK 2,5/2A | ZSLN 2,5/2A ZSRK 2,5/2A | ZSLN 2,5/2A
ZSRK 2,5/3A/15 | ZSLN 2,5/3A/15 ZSRK 2,5/3A/15 | ZSLN 2,5/3A/15 ZSRK 2,5/3A/15 | ZSLN 2,5/3A/15 ZSRK 2,5/3A/15 | ZSLN 2,5/3A/15 ZSRK 2,5/3A/15 | ZSLN 2,5/3A/15 ZSRK 2,5/3A/15 | ZSLN 2,5/3A/15 ZSRK 2,5/3A/35 | ZSLN 2,5/3A/35 ZSRK 2,5/3A/35 | ZSLN 2,5/3A/35 ZSRK 2,5/3A/35 | ZSLN 2,5/3A/35 ZSRK 2,5/3A/35 | ZSLN 2,5/3A/35 ZSRK 2,5/3A/35 | ZSLN 2,5/3A/35 ZSRK 2,5/3A/35 | ZSLN 2,5/3A/35
Width1.5 mm 1.5 mm 1.5 mm 1.5 mm 1.5 mm 1.5 mm 1.5 mm 1.5 mm 1.5 mm 1.5 mm 1.5 mm 1.5 mm 1.5 mm 1.5 mm 1.5 mm 1.5 mm 1.5 mm 1.5 mm
MaterialPA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0
End plates for standard compact terminal blocks ZSRK/ZSLN
280
Specific accessories, pressure-spring connection system (FRK)
End plates / Visual separation
End plates | Visual separation
Tension-spring connection system
TypeZAP 6/2A BG ZAP 6/2A BU ZAP 6/2A OG ZAP 6/2A GN ZAP 6/2A RD ZAP 6/2A YE
ZAP 10/2A BG ZAP 10/2A BU ZAP 10/2A OG ZAP 10/2A GN ZAP 10/2A RD ZAP 10/2A YE ZAP 16/2A BG ZAP 16/2A BU ZAP 16/2A OG ZAP 16/2A GN ZAP 16/2A RD ZAP 16/2A YE
Cat. no..3760.2 3760.5 3760.3 3760.1 3760.9 3760.8 3788.2 3788.5 3788.3 3788.1 3788.9 3788.8 3799.2 3799.5 3799.3 3799.1 3799.9 3799.8
Colourbeige blue
orange green
red yellow beige blue
orange green
red yellow beige blue
orange green
red yellow
Qty.20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20
For terminalZRK 6/2A | ZSL 6/2A ZRK 6/2A | ZSL 6/2A ZRK 6/2A | ZSL 6/2A ZRK 6/2A | ZSL 6/2A ZRK 6/2A | ZSL 6/2A ZRK 6/2A | ZSL 6/2A
ZRK 10/2A | ZSL 10/2A ZRK 10/2A | ZSL 10/2A ZRK 10/2A | ZSL 10/2A ZRK 10/2A | ZSL 10/2A ZRK 10/2A | ZSL 10/2A ZRK 10/2A | ZSL 10/2A ZRK 16/2A | ZSL 16/2A ZRK 16/2A | ZSL 16/2A ZRK 16/2A | ZSL 16/2A ZRK 16/2A | ZSL 16/2A ZRK 16/2A | ZSL 16/2A ZRK 16/2A | ZSL 16/2A
Width2 mm 2 mm 2 mm 2 mm 2 mm 2 mm 2 mm 2 mm 2 mm 2 mm 2 mm 2 mm 2 mm 2 mm 2 mm 2 mm 2 mm 2 mm
MaterialPA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0
End plates for standard terminal blocks ZRK/ZSL
TypeZAPT 2,5/2A BG ZAPT 2,5/2A BU ZAPT 2,5/2A OG ZAPT 2,5/2A GN ZAPT 2,5/2A RD ZAPT 2,5/2A YE ZAPT 2,5/3A BG ZAPT 2,5/3A BU ZAPT 2,5/3A OG ZAPT 2,5/3A GN ZAPT 2,5/3A RD ZAPT 2,5/3A YE ZAPT 2,5/4A BG ZAPT 2,5/4A BU ZAPT 2,5/4A OG ZAPT 2,5/4A GN ZAPT 2,5/4A RD ZAPT 2,5/4A YE
Cat. no..3796.2 3796.5 3796.3 3796.1 3796.9 3796.8 3797.2 3797.5 3797.3 3797.1 3797.9 3797.8 3798.2 3798.5 3798.3 3798.1 3798.9 3798.8
Colourbeige blue
orange green
red yellow beige blue
orange green
red yellow beige blue
orange green
red yellow
Qty.20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20
For terminalZTRK 2,5/2A ZTRK 2,5/2A ZTRK 2,5/2A ZTRK 2,5/2A ZTRK 2,5/2A ZTRK 2,5/2A ZTRK 2,5/3A ZTRK 2,5/3A ZTRK 2,5/3A ZTRK 2,5/3A ZTRK 2,5/3A ZTRK 2,5/3A ZTRK 2,5/4A ZTRK 2,5/4A ZTRK 2,5/4A ZTRK 2,5/4A ZTRK 2,5/4A ZTRK 2,5/4A
Width1.5 mm 1.5 mm 1.5 mm 1.5 mm 1.5 mm 1.5 mm 1.5 mm 1.5 mm1.5 mm 1.5 mm 1.5 mm 1.5 mm 1.5 mm 1.5 mm 1.5 mm 1.5 mm1.5 mm1.5 mm
MaterialPA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0
End plates for disconnect and fused terminal blocks ZTRK
TypeZAPD 2,5 BG ZAPD 2,5 BU ZAPD 2,5 OG ZAPD 2,5 GN ZAPD 2,5 RD ZAPD 2,5 YE
Cat. no..3756.2 3756.5 3756.3 3756.1 3756.9 3756.8
Colourbeige blue
orange green
red yellow
Qty.20 20 20 20 20 20
For terminalZRKD 2,5 | ZSLD 2,5 ZRKD 2,5 | ZSLD 2,5 ZRKD 2,5 | ZSLD 2,5 ZRKD 2,5 | ZSLD 2,5 ZRKD 2,5 | ZSLD 2,5 ZRKD 2,5 | ZSLD 2,5
Width2 mm 2 mm 2 mm 2 mm 2 mm 2 mm
MaterialPA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0 PA 6.6 V0
End plates for double-level terminal blocks ZRKD/ZSLD
TypeZAP/TW/ZIZA 1,5/3 BG ZAP/TW/ZIZA 1,5/4 BG
ZAP ZMP BG
Cat. no..3746.2 3747.23785.2
Colourbeigebeigebeige
Qty.20 2020
For terminalZIZA 1,5/3 | ZIZA 1,5/3/PE ZIZA 1,5/4 | ZIZA 1,5/4/PE
ZMP 1,5
Width5 mm 5 mm5 mm
MaterialPA 6.6 V0 PA 6.6 V0 PA 6.6 V0
End plates for initiator terminal blocks ZINI/ZAKTO/ZMP
TypeZAP 2,5/ID BG ZAP 2,5/ID BU ZAP 2,5/ID OG ZAP 2,5/ID GN ZAP 2,5/ID RD ZAP 2,5/ID YE ZAP MA BG ZAP MA BU
Cat. no..3761.2 3761.5 3761.3 3761.1 3761.9 3761.8 3762.2 3762.5
Colourbeige blue
orange green
red yellow beige blue
Qty.20 2020202020 2020
For terminalZIKD 2,5 ZIKD 2,5 ZIKD 2,5 ZIKD 2,5 ZIKD 2,5 ZIKD 2,5
ZVMAK 2,5 ZVMAK 2,5
Width1.5 mm 1.5 mm 1.5 mm 1.5 mm 1.5 mm 1.5 mm 1.5 mm 1.5 mm
MaterialPA 6.6 V0 PA 6.6 V0PA 6.6 V0 PA 6.6 V0 PA 6.6 V0PA 6.6 V0PA 6.6 V0PA 6.6 V0
End plates for multi-level terminal blocks ZIKD/ZVMAK
281
GEN
ERA
L A
CC
ESSO
RIE
S
282
Insulated cross-connections SQI (potential distribution)
The SQI pluggable cross-connection system allows you tosave time and money by distributing voltage potentialsacross terminal blocks of similar or different cross-sectionranges. The pluggable design of the SQI offers the advan-tage that it can carry the rated current even while operatingat the rated voltage! The SQI is constructed to protectagainst accidental touch. It is available in 2 – 10 poles and in30 pole versions. Since the standard terminal blocks featuretwo cross-connection channels, it is possible to connect dif-ferent voltage potentials in parallel with no loss of poles.
CONTA-CONNECT
282
Individual cross-connection contact elements can be takenout of the row in order to skip over feed-through terminals(SRK) or PE terminals (SSL). This allows two different voltagepotentials to be conducted using a single terminal rail config-uration. You can mark these broken-off contact elementsusing the plastic insulation of the cross-connector.
It is possible to shorten the SQI cross-connection with a cut-ting tool. The SQI system allows you to maintain touch-pro-tection safety by covering the cut (uninsulated) end with aSQIK insulation cap.
In order to help distinguish between different potentials, oth-er colour variants are available for the SQI 2,5, SQI 4, SQI 6and SQI 10 cross-connectors.
283
Insulated cross-connections SQI (potential distribution)
Usage of the SQI
Cross-connection options
Insulated cross-connections SQI (potential distribution)
283
Simple Side-by-side Alternating
Parallel alternating Parallel extended Chain linked
The 30-pole cross-connector features a numbered scale
which allows the user to easily count off or shorten to the
number of required poles.
GEN
ERA
L A
CC
ESSO
RIE
S
✘ ✔
Insulated cross-connections SQI CONTA-CONNECT
The SQI cross-connections for the screw connection system
have a pluggable, insulated design. They can be used to con-
duct the rated current of the corresponding cross-section
range. The terminal block design and the variability of the
cross-connector ensure excellent flexibility.
TypeType/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.
Colours availableRatingsRated current, A | Max. current, AMax. voltage with partition plate, VMax. voltage without partition plate, VRated impulse voltage, kV | Contamination degreePitch, mm
AccessoriesInsulation cap for cross-connector Cat. no.For terminal
SQI 2,5...
SQI 2,5/2 YE17201.8SQI 2,5/3 YE17202.8SQI 2,5/4 YE17203.8SQI 2,5/5 YE17204.8SQI 2,5/6 YE17205.8SQI 2,5/7 YE17206.8SQI 2,5/8 YE17207.8SQI 2,5/9 YE17208.8SQI 2,5/10 YE17209.8SQI 2,5/30 YE17210.8
IEC24 | 3210001000- |35
SQIK 2,5-10 YE17200.8
SRK 2,5...SSL 2,5...
SQI 4...
SQI 4/2 YE17211.8SQI 4/3 YE17212.8SQI 4/4 YE17213.8SQI 4/5 YE17214.8SQI 4/6 YE17215.8SQI 4/7 YE17216.8SQI 4/8 YE17217.8SQI 4/9 YE17218.8SQI 4/10 YE17219.8SQI 4/30 YE17220.8
IEC32 | 4110001000- |36
SQIK 2,5-10 YE17200.8
SRK 4...SSL 4...
SQI 6...
SQI 6/2 YE17221.8SQI 6/3 YE17222.8SQI 6/4 YE17223.8SQI 6/5 YE17224.8SQI 6/6 YE17225.8SQI 6/7 YE17226.8SQI 6/8 YE17227.8SQI 6/9 YE17228.8SQI 6/10 YE17229.8SQI 6/30 YE17230.8
IEC41 | 5710001000- |38
SQIK 2,5-10 YE17200.8
SRK 6...SSL 6...
2 poles
3 poles
4 poles
5 poles
6 poles
7 poles
8 poles
9 poles
10 poles
30 poles
Qty.
50
50
20
20
20
20
10
10
10
5
Qty.
50
50
20
20
20
20
10
10
10
5
Qty.
50
50
20
20
20
20
10
10
10
5
Qty.
20Remarks Remarks Remarks
Page
285
Qty.
20
Page
285
Qty.
20
Page
285
Cross-connection insulated
Cross-connection insulated
Cross-connection insulated
284
.9.8.5.4 .9.8.5.4 .9.8.5.4
SQIK 2,5-10
SQIK 2,5-10 YE17200.8
Qty.
20
Insulation cap forCross-connectors
SQI 10...
SQI 10/2 YE17231.8SQI 10/3 YE17232.8SQI 10/4 YE17233.8SQI 10/5 YE17234.8SQI 10/6 YE17235.8SQI 10/7 YE17236.8SQI 10/8 YE17237.8SQI 10/9 YE17238.8SQI 10/10 YE17239.8SQI 10/30 YE17240.8
IEC57 | 7610001000- |310
SQIK 2,5-10 YE17200.8
SRK 10...SSL 10...
Qty.
50
50
20
20
20
20
10
10
10
5
Qty.
20Remarks
Page
285
Cross-connection insulated
285
.9.8.5.4
GEN
ERA
L A
CC
ESSO
RIE
S
Outlet through
SRK 2,5/2A BG (17100.2)SRK 4/2A BG (17104.2)
SRK 6/2A BG (17108.2)SRK 10/2A BG (17112.2)
SRK 2,5/2A BG (17100.2)
SRK 4/2A BG (17104.2)SRK 6/2A BG (17108.2)
SRK 10/2A BG (17112.2)
SRK 2,5/2A BG (17100.2)SRK 4/2A BG (17104.2)
SRK 6/2A BG (17108.2)SRK 10/2A BG (17112.2)
SRK 2,5/2A BG (17100.2)SRK 4/2A BG (17104.2)SRK 6/2A BG (17108.2)
SRK 10/2A BG (17112.2)
Feed on left start
SQI 2,5/…SQI 2,5/2SQI 4/…SQI 4/2SQI 6/2
SQI 2,5/…SQI 4/2SQI 4/…SQI 4/2SQI 6/…SQI 6/2
SQI 4/2SQI 4/…SQI 6/2SQI 6/…SQI 6/2SQI 10/…
SQI 6/2SQI 6/2SQI 6/…SQI 10/2SQI 10/…
Feed on right end
SQI 2,5/…SQI 2,5/2SQI 4/…SQI 4/2SQI 6/2
SQI 2,5/…SQI 4/2SQI 4/…SQI 4/2SQI 6/…SQI 6/2
SQI 4/2SQI 4/…SQI 6/2SQI 6/…SQI 6/2SQI 10/…
SQI 6/2SQI 6/2SQI 6/…SQI 10/2SQI 10/…
Feed-in through
SRK 2,5/2A BG (17100.2)
SRK 4/2A BG (17104.2)
SRK 6/2A BG (17108.2)
SRK 10/2A BG (17112.2)
Cross-connector SQI (feeding potentials)
The SQI pluggable cross-connection systemhelps you to save time while distributing poten-tials over terminal blocks of similar or differentcross-sections. The pluggable design of the SQIoffers the advantage that it can carry the ratedcurrent even while operating at the rated volt-age! The SQI is constructed to protect againstaccidental touch. It is available in 2 – 10 polesand in 30 pole versions. You can break out indi-vidual contact poles (without pole loss) in orderto guide different potentials in parallel or to skipover terminal blocks.
286286
Uninsulated cross-connections Q | Insulated cross-connections QI (potential distribution)
CONTA-CONNECT
286
The Q/QI screwable cross-connection system allows you to save time while distributingpotentials between terminal blocks of the same cross-section range. The QI has a touch-safe design and, like the Q cross-connection system, is available with 2, 3, 4 or 10 poles.Parallel connections between various potentials, without loss of poles, is possible with theQI system in cross-sections ranging from 2.5 mm2 to 10 mm2.
Skip-over bridging
With the standard terminal blocks, it is possible to skip over terminal blocks by break-ing out (QI) or unscrewing (Q) individual contact poles.
Shortening cross-connections
It is possible to shorten the cross-connections with a cutting tool, but you must thenmake sure that the cut side is fitted with an end plate so that the voltage rating is main-tained.
Q/QI pre-assembled cross-connectors
The pre-assembled cross-connectors feature a cross-connection rail, connecting sleeveand attachment screw already assembled in the appropriate number of poles so thatthey cannot be lost. During installation, these pre-assembled cross-connectors needonly be inserted into the appropriate terminal row. The cross-connection units are avail-able in versions with 2, 3, 4 or 10 poles. Depending on the type of terminal block, weoffer either insulated QI cross-connectors and/or uninsulated Q cross-connectors.
Q
QI
Cross-connecting (with Q/QI) one potential over more than ten terminalblocks.
From the cross-connection, the first or last screw is unscrewed from the VH. TheQS 2 or QI 2 without VH is put in and then both screws are screwed back in to theVH.
Q QI
Individual components of cross-connection Q (QS + VH + BS = Q) QS cross-con-nection rails
Cross-connection rails can be used in order to cross-connect identical potentials acrossmultiple terminal blocks. The cross-connection rails are made of copper or brass. They havea galvanized nickel-plated surface. These cross-connection rails are delivered in 2-pole, 3-pole, 4-pole and 10-pole lengths – corresponding to the width of the terminal. Thecross-connection rail is connected electrically using a connecting sleeve with the busbar inthe terminal block. We offer cross-connection rails in 0.5 m length to fit with certain termi-nal blocks. This allows you to put together cross-connections for any number of poles.
QS
VH connecting sleevesThe VHs have a customized lengthbased on the corresponding terminal.They are made from copper or brass.They have a nickel-plated surface. AVH must be used for each terminalthat is being cross-connected.
VH BS mounting screwsA steel screw is used to attach thecross-connection rail with the sleeve(VH) to the busbar on the terminalblock. The steel screw ensures that thecross-connection unit has a strongmechanical connection to the busbar.
BS
287287
Uninsulated cross-connections Q | Insulated cross-connections QI (potential distribution)
287
Examples
Variability of the screwable cross-connectorPre-assembled cross-connection units – in 2, 3, 4, 10, or 40-pole ver-sions – significantly reduce the assembly time. There are additionaladvantages with the QI insulated cross-connections when using termi-nal blocks up to 10 mm2. Because of its angled design, two QIs can beassembled offset (staggered). Thus it is possible to achieve the parallelguiding of two potentials. Since the QI is insulated and touch-safeaccording to VDE 0106 section 100, it is not necessary to use end platesor partitions between neighbouring cross-connection up to 400 V. TheQI cross-connections can carry the rated current of the terminal blocks.It is also possible to skip terminals, since the individual contact ridgescan be broken off.
Usage of the QI
Cross-connection options
Simple Side-by-side Alternating Parallel alternating Extended
Switchable cross-connections switchable cross-connections are meant for 2-pole cross-connections that are easily separated.A VH-type connecting sleeve and a BS-type screw are used for installation.
Switchable cross-connection QL 2
Switchable cross-connection QLType
QL 2QL 2QL 2QL 2
Cat. no.
2076.02008.02053.02106.0
Qty.
50505050
Connecting sleeve VHType
VH 16VH 19VH 19VH 19
Cat. no.
2077.02009.02009.02009.0
Qty.
100100100100
Mounting screw BSType
BS M2,5x20BS M3x25BS M3x25BS M3x25
Cat. no.
2078.02010.02010.02010.0
Qty.
100100100100
For terminalType
RK 1,5-4 |RKD 4RK 2,5-4RK 6-10RK 16
GEN
ERA
L A
CC
ESSO
RIE
S
Uninsulated cross-connections Q | Insulated cross-connections QICONTA-CONNECT
The Q/QI screwable, pre-assembled cross-connection systemallows you to save time while distributing potentials betweenterminal blocks of the same cross-section range.
Available with 2, 3, 4, 10, 40, 83 and 100 poles
TypeType/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.
RatingsRated current, AMax. voltage with partition plate, VMax. voltage without partition plate, V Rated impulse voltage, kV | Contamination degreePitch, mm
Connection dataTorque, Nm | Screw
AccessoriesScrewdriverCat. no.For terminal
All terminals marked with a “1” are, when used with thecorresponding cross-connector, totally protected againsttouch, in accordance with the regulations for accident pre-vention “Electrical facilities and operating devices” (VBG 4and VDE 0106 part 100/3.83).
All terminals marked with a “2” should, when used withthe corresponding cross-connector, be fitted with a cover(for example, ADQ, EA 1 or similar) in order to ensure totaltouch-safety protection.
*Partitions or end platesshould be used betweenneighbouring cross-connec-tions.
Q...(2.5mm2)
Q 22832.0Q 32833.0Q 42834.0Q 102835.0Q 202836.0Q 0.5 m/83 poles2154.0
IEC20
400400*
-|36
0.4-0.8|M2.5
SDB 0.6x3.51086.0
DLI 2,5/...DLIS 2,5/...
Q...(2.5mm2)
Q 22422.0Q 32423.0Q 42424.0Q 102425.0Q 202700.0Q 0.5 m/100 poles2151.0
IEC20
400400*
-|35
0.4-0.8|M2.5
SDB 0.6x3.51086.0
SRK 2,5/15SRK 2,5/IK 2,5IKD 2,5
Q...(2.5mm2)
Q 22567.0Q 32568.0Q 42569.0Q 102570.0
Q 0.5 m/100 poles2152.0
IEC20
800400*
-|35
0.4-0.8|M2.5
SDB 0.6x3.51086.0
RK 2,5KBL 2,5
RKD 2.5...KBLD 2,5Reduce the voltage to 400 V when usedtogether with double-level terminals!
2 poles
3 poles
4 poles
10 poles
20 poles
Multi-pole
Qty.
50
50
20
10
10
1
Qty.
50
50
20
10
10
1
Qty.
50
50
20
10
1
Qty.
1Remarks
- -
Remarks1111
Remarks11
11
Page
422
Qty.
1
Page
422
Qty.
1
Page
422
Cross-connection Uninsulated
Cross-connection Uninsulated
Cross-connection Uninsulated
288
*Partitions or end platesshould be used betweenneighbouring cross-connec-tions.
All terminals marked with a “1” are, when used with thecorresponding cross-connector, totally protected againsttouch, in accordance with the regulations for accident pre-vention “Electrical facilities and operating devices” (VBG 4and VDE 0106 part 100/3.83).
All terminals marked with a “2” should, when used withthe corresponding cross-connector, be fitted with a cover(for example, ADQ, EA 1 or similar) in order to ensuretotal touch-safety protection.
Cross-connection Uninsulated
Cross-connection Uninsulated
Cross-connection insulated
Cross-connection Uninsulated
Cross-connection insulated
Q...(4mm2)
Q 22019.0Q 32020.0Q 42021.0Q 102022.0
Q 0.5 m/83 poles2153.0
IEC27
800400*
-|36
0.5-1.0|M3
SDB 0.6x3.51086.0
RK 2,5 - 4RK 2,5-4 ZRRK 2,5-4 ZRLKBL 2,5-4FF 2.5SF2,5
Qty.
50
50
20
10
1
Remarks222222
Qty.
1
Page
422
QI...(4mm2)
QI 2 YE2740.2QI 3 YE2741.2QI 4 YE2742.2QI 10 YE2743.2
QI 40 YE2746.2
IEC32
800400-|36
0.5-1.0|M3
SDB 0.6x3.51086.0
RK 2,5 - 4RK 2,5-4 ZRRK 2,5-4 ZRLKBL 2,5-4FF 2.5SF2,5
Qty.
50
50
20
10
1
Remarks111111
Qty.
1
Page
422
Q...(10mm2)
Q 22060.0Q 32061.0Q 42062.0Q 102063.0
IEC47
800400*
-|38
0.5-1.0|M3
SDB 0.6x3.51086.0
RK 6 -10KBL 6 -10
Qty.
50
50
20
10
Remarks22
Qty.
1
Page
422
Qty.
50
50
20
10
Remarks11
Qty.
1
Page
422
Q...(4mm2)
Q 22087.0Q 32088.0Q 42089.0Q 102090.0
Q 0.5 m/100 poles2150.0
IEC20
800400*
-|36
0.4-0.8|M2.5
SDB 0.6x3.51086.0
RK 1,5 - 4/15RK 1,5/4KBL 1,5-4/15KBL 1,5-4
RKD 4...RKDG 4Reduce the voltage to 400 V when usedtogether with double-level terminals!
Qty.
50
50
20
10
1
Qty.
1Remarks
1111
11
Page
422
289
GEN
ERA
L A
CC
ESSO
RIE
S
QI...(10mm2)
ZVQI 2,5 OG3472.8QI 2 YE2750.2QI 3 YE2751.2QI 4 YE2752.2QI 10 YE2753.2
IEC57
800400-|38
0.5-1.0|M3
SDB 0.6x3.51086.0
RK 6 -10KBL 6 -10
Uninsulated cross-connections Q | Switchable cross-connections QLCONTA-CONNECT
The Q/QI screwable, pre-assembled cross-connection systemallows you to save time while distributing potentials betweenterminal blocks of the same cross-section range.
Available with 2, 3, 4, and 10 poles.
TypeType/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.
RatingsRated current, AMax. voltage with partition plate, VMax. voltage without partition plate, V Rated impulse voltage, kV | Contamination degreePitch, mm
Connection dataTorque, Nm | Screw
AccessoriesScrewdriverCat. no.For terminal
Q...(16 mm2)
Q 22112.0Q 32113.0Q 42114.0Q 102115.0
IEC47
800400*
-|312
0.5-1.0|M3
SDB 0.6x3.51086.0
RK 16
Q...(16 mm2)
Q 22257.0Q 32258.0Q 42265.0Q 102266.0
IEC47
800400*
-|312
0.5-1.0|M3
SDB 0.6x3.51086.0
RK 16/35 N
Q...(35 mm2)
Q 22164.0Q 32165.0Q 42166.0Q 102167.0
IEC65
800400*
-|316
1.2-2.0|M4
SDB 0,8x4,01087.0
RK 35RK 35/35 N
Qty.
20
20
10
10
Qty.
20
20
10
10
Qty.
20
20
10
10
Qty.
1Remarks
1Remarks
1Remarks
12
Page
422
Qty.
1
Page
422
Qty.
1
Page
422
Cross-connection Uninsulated
Cross-connection Uninsulated
Cross-connection Uninsulated
2 poles
3 poles
4 poles
10 poles
All terminals marked with a “1” are, when used with thecorresponding cross-connector, totally protected againsttouch, in accordance with the regulations for accident pre-vention “Electrical facilities and operating devices” (VBG 4and VDE 0106 part 100/3.83).
All terminals marked with a “2” should, when used withthe corresponding cross-connector, be fitted with a cover(for example, ADQ, EA 1 or similar) in order to ensure totaltouch-safety protection.
290
*Partitions or end platesshould be used betweenneighbouring cross-connec-tions.
QL 2
QL 22008.0
When combined with:Connecting sleeve VHVH 192009.0andMounting screw BSBS M 3x252010.0
IEC24---|36
0.5-1.0|M3
SDB 0.6x3.51086.0
RK 2,5 - 4Remarks
No touch-safety protection!
Qty.
1
Page
422
QL 2
QL 22053.0
When combined with:Connecting sleeve VHVH 192009.0andMounting screw BSBS M 3x252010.0
IEC32---|38
0.5-1.0|M3
SDB 0.6x3.51086.0
RK 6 - 10Remarks
No touch-safety protection!
Qty.
1
Page
422
QL 2
QL 22106.0
When combined with:Connecting sleeve VHVH 192009.0andMounting screw BSBS M 3x252010.0
IEC41---|312
0.5-1.0|M3
SDB 0.6x3.51086.0
RK 16Remarks
No touch-safety protection!
Qty.
1
Page
422
QL 2
ZVQI 2,5 OG3472.8QL 22306.0
When combined with:Connecting sleeve VHVH 172122.0andMounting screw BSBS M 4x302123.0
IEC57---|316
1,2-2,0|M4
SDB 0.6x3.51086.0
RK 35Remarks
No touch-safety protection!
Qty.
1
Page
422
QL 2
QL 22076.0
When combined with:Connecting sleeve VHVH 162077.0andMounting screw BSBS M 2,5x202078.0
IEC24---|36
0.4-0.8|M2.5
SDB 0.6x3.51086.0
RK 1,5 - 4RKD 4
Qty.
50
100
100
Qty.
50
100
100
Qty.
50
100
100
Qty.
50
100
100
Qty.
50
50
50
Qty.
1Remarks
No touch-safety protection!No touch-safety protection!
Page
422
Switchable cross-connection
Switchable cross-connection
Switchable cross-connection
Switchable cross-connection
Switchable cross-connection
Switchable cross-connections are meant for 2-pole cross-connections that are easily separated. A VH-type connect-ing sleeve and a BS-type screw are used for installation.
291
GEN
ERA
L A
CC
ESSO
RIE
S
External insulated cross-connection AQICONTA-CONNECT
External cross-connector AQIExternal cross-connection bridges make it possible tobranch off the current for terminals, which are not avail-able in the middle of the terminal, via a cross-connectionchannel.
When external cross-connections are used, the rated cross-section is reduced to the next smallest wire size.
TypeType/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.
RatingsRated current, AMax. voltage with partition plate, VMax. voltage without partition plate, VRated impulse voltage, kV | Contamination degreePitch, mm
Connection dataTorque, Nm | Screw
AccessoriesTypeCat. no.For terminal
AQI.../5/11
AQI 2/5/11 YE2032.0AQI 3/5/11 YE2033.0AQI 4/5/11 YE2044.0AQI 10/6/11 YE2045.0
AQI 95/5/11 YE2107.0
IEC27---|35
-|-
SRK 2,5/15SRK 2,5RKD 2,5IK 2,5IKD 2,5BKA 2,5
AQI.../5/15
AQI 2/8/11 YE2023.0AQI 3/5/15 YE2024.0AQI 4/5/15 YE2028.0AQI 10/5/15 YE2029.0
AQI 95/5/15 YE2030.0
IEC27---|35
-|-
RK 2,5RK 2,5/35/N/2QZSRK 2,5...ZRK 2,5...ZRKD 2,5...ZIKD 2,5...ZTRK 2,5ZIZA 1,5SRK 2,5/2A
AQI.../6/11
AQI 2/6/11 YE2125.0AQI 3/6/11 YE2126.0AQI 4/6/11 YE2140.0AQI 10/6/11 YE2141.0
AQI 75/6/11 YE2481.0
IEC27---|36
-|-
RK 1,5-4/15RK 1,5-4RKB 4RKD 4BKA 4VMAK 2,5
2 poles
3 poles
4 poles
10 poles
Multi-pole
Qty.
50
50
10
10
10
Qty.
50
50
10
10
10
Qty.
50
50
10
10
10
Qty.
Remarks1
Remarks1
Remarks12
Page Qty.Page Qty.Page
External cross-connection insulated
External cross-connection insulated
External cross-connection insulated
292
External cross-connection insulated
External cross-connection insulated
External cross-connection insulated
External cross-connection insulated
External cross-connection insulated
AQI.../8/11
AQI 2/8/11 YE2067.0AQI 3/8/11 YE2068.0AQI 4/8/11 YE2069.0
IEC27---|38
-|-
BKA 10SRK 10/2ASTK 1STK 2STKD 1
Qty.
50
50
50
Remarks
Qty.Page
AQI.../8/18
AQI 2/8/18 YE3440.8AQI 3/8/18 YE3441.8AQI 4/8/18 YE3442.8AQI 10/8/18 YE3443.8
AQI 60/8/18 YE3444.8
IEC57---|38
-|-
RK 6-10KBL 6-10SIK 10PTKSRK 6/2A
Qty.
50
50
50
10
1
Remarks
Qty.Page
AQI.../10/18
AQI 2/8/18 YE3991.8AQI 3/10/18 YE3992.8AQI 4/10/18 YE3993.8AQI 10/10/18 YE3994.8
AQI 50/10/18 YE3995.8
IEC57---|310
-|-
SIK 10 ZSRK 10/2A
Qty.
50
50
50
10
1
Remarks
Qty.Page
AQI.../50
ZVQI 2,5 OG3472.8AQI 2/50 YE2763.2AQI 3/50 YE2764.2
IEC150
10001000
-|320
-|-
RK 50
Qty.
5
5
Remarks
Qty.Page
AQI.../6/17
AQI 4/6/11 YE2064.0AQI 3/6/17 YE2065.0AQI 4/6/17 YE 2066.0AQI 10/6/17 YE 2143.0
AQI 10/6/11 YE2480.0
IEC27---|36
-|-
RK 2,5-4RK 2,5-4 ZRRK 2,5-4 ZRLTRK 1,5SRK 4/2A
Qty.
50
50
10
10
10
Qty.
Remarks
Page
293
GEN
ERA
L A
CC
ESSO
RIE
S
External insulated cross-connection AQI CONTA-CONNECT
External cross-connection AQI
External cross-connection bridges make it possible tobranch off the current for terminals which are not availablein the middle of the terminal via a cross-connection chan-nel.When external cross-connections are used, the rated cross-section is reduced to the next smallest wire size.
TypeType/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.
RatingsRated current, AMax. voltage with partition plate, VMax. voltage without partition plate, VRated impulse voltage, kV | Contamination degreePitch, mm
Connection dataTorque, Nm | Screw
AccessoriesTypeCat. no.For terminal
AQI.../95
AQI 2/95 YE2765.2AQI 3/95 YE2766.2
IEC232
10001000
|325
-|-
RK 95
AQI.../150
AQI 2/150 YE2767.2AQI 3/150 YE2768.2
IEC309
10001000
|331
-|-
RK 150
AQI.../240
AQI 2/240 YE2769.2AQI 3/240 YE2770.2
IEC380
10001000
|336
-|-
RK 240
2 poles
3 poles
4 poles
10 poles
20 poles
Multi-pole
Uninsulated straight
Uninsulated angled
Insulation section
Qty.
5
5
Qty.
5
5
Qty.
5
5
Qty.
Remarks Remarks Remarks
Page Qty.Page Qty.Page
External cross-connection insulated
External cross-connection insulated
External cross-connection insulated
294
Bridgeable PEN power feed blocks
When five-wire power suppliesare connected to a mains supply,then a conductive connectionmust be established between theSL PE terminal and the N neutralterminal.
The AQV 2 PEN external cross-connector fulfils this requirement.
External cross-connection AQ
External cross-connection make it possible to branch offthe current for terminals which are not available in themiddle of the terminal via a cross-connection channel.The AQ 58 type is delivered as a 58-pole version. Its con-tact elements can easily be broken out by hand. Theattachable insulation section IP is available for the AQ 58.When external cross-connections are used, the ratedcross-section is reduced to the next smallest wire size.
TypeType/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.
RatingsRated current, AMax. voltage with partition plate, VMax. voltage without partition plate, VRated impulse voltage, kV | Contamination degreePitch, mm
Connection dataTorque, Nm | Screw
AccessoriesTypeCat. no.For terminal
295
External cross-connection Uninsulated
AQ
AQ 58 straight2477.0AQ 58 angled2478.0
IP 582479
IEC24
8
-|-
Straight versionRK 6-10KBL 6-10
Angled versionSIK 10PTK
Qty.
10
10
10
Remarks
Qty.Page
AQV
AQV 2 PE/N 102181.0
AQV 2 PE/N 162182.0
AQV 2 PE/N 352183.0
IEC----
8,12,16
-|-
AQV 2 PE/N 10 for terminals SL10/35 and RK 6- 10 BU
AQV 2 PE/N 16 for terminals SL16/35 and RK 16 BU
AQV 2 PE/N 35 for terminals SL35/35 and RK 35 BU
Qty.
10
10
10
Remarks
Qty.Page
Jumper PEN
Uninsulated external cross-connection AQ | Bridgeable PEN power feed blocks
GEN
ERA
L A
CC
ESSO
RIE
S
CONTA-CONNECT
296296
Uninsulated cross-connections Q
Screw connection system
Cross-connections Q
Cross-section
2.5 mm2
2.5 mm2
2.5 mm2
2.5 mm2
2.5 mm2
2.5 mm2
2.5 mm2
2.5 mm2
2.5 mm2
2.5 mm2
2.5 mm2
2.5 mm2
2.5 mm2
2.5 mm2
2.5 mm2
2.5 mm2
2.5 mm2
4 mm2
4 mm2
4 mm2
4 mm2
4 mm2
4 mm2
4 mm2
4 mm2
4 mm2
4 mm2
10 mm2
10 mm2
10 mm2
10 mm2
16 mm2
16 mm2
16 mm2
16 mm2
16 mm2
16 mm2
16 mm2
16 mm2
35 mm2
35 mm2
35 mm2
35 mm2
Cross-connections Q / self-assembly
TYPE
Q 2Q 3Q 4Q 10Q 20 Q 0.5 m/83 poles
Q 2Q 3Q 4Q 10Q 20 Q 0.5 m/100 poles
Q 2Q 3Q 4Q 10Q 0.5 m/100 poles
Q 2Q 3Q 4Q 10Q 0.5 m/83 poles
Q 2Q 3Q 4Q 10Q 0.5 m/83 poles
Q 2Q 3Q 4Q 10
Q 2Q 3Q 4Q 10
Q 2Q 3Q 4Q 10
Q 2Q 3Q 4Q 10
Q 2 for SK 1/35Q 3 for SK 1/35Q 4 for SK 1/35Q 10 for SK 1/35
QS cross-connection rail
Cat. no.
2081.02082.02083.02084.02588.02386.0
2417.02418.02419.02420.02587.02519.0
2417.02418.02419.02420.02519.0
2081.02082.02083.02084.02386.0
2013.02014.02015.02016.02387.0
2055.02056.02057.02058.0
2108.02109.02110.02111.0
2108.02109.02110.02111.0
2118.02119.02120.02121.0
2366.02367.02368.02369.0
Qty.
1001005010101
1001005010101
10010050101
10010050101
10010050101
1001005010
1001005010
1001005010
1001005010
1001005010
b4,24,24,24,24,24,2
4,24,24,24,24,24,2
4,24,24,24,24,2
4,24,24,24,24,2
66666
6666
6666
6666
8888
6666
d111111
111111
11111
11111
22222
2222
2222
2222
3333
2222
L666666
555555
55555
66666
66666
8888
12121212
12121212
16161616
12121212
d12.72.72.72.72.72.7
2.72.72.72.72.72.7
2.72.72.72.72.7
2.72.72.72.72.7
3.43.43.43.43.4
3.43.43.43.4
3.43.43.43.4
3.43.43.43.4
4.54.54.54.5
3.43.43.43.4
Dimensions, mm Requiredamount
111111
111111
11111
11111
11111
1111
1111
1111
1111
1111
TYPE
QS 2QS 3QS 4QS 10QS 20QS 0.5 m
QS 2QS 3QS 4QS 10QS 20QS 0.5 m
QS 2QS 3QS 4QS 10QS 0.5 m
QS 2QS 3QS 4QS 10QS 0.5 m
QS 2QS 3QS 4QS 10QS 0.5 m
QS 2QS 3QS 4QS 10
QS 2QS 3QS 4QS 10
QS 2QS 3QS 4QS 10
QS 2QS 3QS 4QS 10
QS 2QS 3QS 4QS 10
Cat. no.
2832.02833.02834.02835.02836.02154.0
2422.02423.02424.02425.02700.02151.0
2567.02568.02569.02570.02152.0
2087.02088.02089.02090.02150.0
2019.02020.02021.02022.02153.0
2060.02061.02062.02063.0
2112.02113.02114.02115.0
2257.02258.02265.02266.0
2164.02165.02166.02167.0
Caution:It is not possible to constructpre-assembled cross-connec-tion units.
For terminalDLI 2,5 | DLIS 2,5
SRK 2,5 | IK 2,5 | IKD 2,5
RK 2,5 | RKD 2,5
RK 1,5-4 | RKD 4
RK 2,5-4
RK 6-10
RK 16
RK 16 N
RK 35
297297
Specific accessories, screw connection system
Cross-connections Q (potential distribution)
Connecting sleeve VH
Cat. no.
2327.02327.02327.02327.02327.02327.0
2327.02327.02327.02327.02327.02327.0
2085.02085.02085.02085.02085.0
2085.02085.02085.02085.02085.0
2017.02017.02017.02017.02017.0
2059.02059.02059.02059.0
2059.02059.02059.02059.0
2283.02283.02283.02283.0
2122.02122.02122.02122.0
----
TYPE
VH 5VH 5VH 5VH 5VH 5VH 5
VH 5VH 5VH 5VH 5VH 5VH 5
VH 8,5VH 8,5VH 8,5VH 8,5VH 8,5
VH 8,5VH 8,5VH 8,5VH 8,5VH 8,5
VH 13.5VH 13.5VH 13.5VH 13.5VH 13.5
VH 12VH 12VH 12VH 12
VH 12VH 12VH 12VH 12
VH 8VH 8VH 8VH 8
VH 17VH 17VH 17VH 17
----
Mounting screw BS / SS
Cat. no.
2326.02326.02326.02326.02326.02326.0
2326.02326.02326.02326.02326.02326.0
2086.02086.02086.02086.02086.0
2086.02086.02086.02086.02086.0
2018.02018.02018.02018.02018.0
2018.02018.02018.02018.0
2018.02018.02018.02018.0
2284.02284.02284.02284.0
2123.0 | 2124.02123.0 | 2124.02123.0 | 2124.02123.0 | 2124.0
2365.02365.02365.02365.0
Qty.
100100100100100100
100100100100100100
100100100100100
100100100100100
100100100100100
100100100100
100100100100
100100100100
50|5050|50 50|50 50|50
100100100100
Dimensions
M2.5x10M2.5x10M2.5x10M2.5x10M2.5x10M2.5x10
M2.5x10M2.5x10M2.5x10M2.5x10M2.5x10M2.5x10
M2.5x14M2.5x14M2.5x14M2.5x14M2.5x14
M2.5x14M2.5x14M2.5x14M2.5x14M2.5x14
M3x20M3x20M3x20M3x20M3x20
M3x20M3x20M3x20M3x20
M3x20M3x20M3x20M3x20
M3x15M3x15M3x15M3x15
M4x30 | M4M4x30 | M4M4x30 | M4M4x30 | M4
M3x6M3x6M3x6M3x6
Qty.
100100100100100100
100100100100100100
100100100100100
100100100100100
100100100100100
100100100100
100100100100
100100100100
50505050
----
L555555
555555
8,58,58,58,58,5
8,58,58,58,58,5
13,513,513,513,513,5
12121212
12121212
8888
17171717
----
d2444444
444444
44444
44444
55555
5555
5555
4,94,94,94,9
8888
----
d12.82.82.82.82.82.8
2.82.82.82.82.82.8
2.82.82.82.82.8
2.82.82.82.82.8
3.53.53.53.53.5
3.53.53.53.5
3.53.53.53.5
3.53.53.53.5
5555
----
Dimensions, mm Requiredamount
234
1020
100
234
1020
100
234
10100
234
1083
234
1083
234
10
234
10
234
10
2 each3 each4 each
10 each
234
10
Requiredamount
234
1020
100
234
1020
100
234
10100
234
1083
234
1083
234
10
234
10
234
10
234
10
----
Type
BS M2,5x10BS M2,5x10BS M2,5x10BS M2,5x10BS M2,5x10BS M2,5x10
BS M2,5x10BS M2,5x10BS M2,5x10BS M2,5x10BS M2,5x10BS M2,5x10
BS M2,5x14BS M2,5x14BS M2,5x14BS M2,5x14BS M2,5x14
BS M2,5x14BS M2,5x14BS M2,5x14BS M2,5x14BS M2,5x14
BS M3x20BS M3x20BS M3x20BS M3x20BS M3x20
BS M3x20BS M3x20BS M3x20BS M3x20
BS M3x20BS M3x20BS M3x20BS M3x20
BS M3x15 w. SSBS M3x15 w. SSBS M3x15 w. SSBS M3x15 w. SS
BS M4x30 | SS M4BS M4x30 | SS M4BS M4x30 | SS M4BS M4x30 | SS M4
BS M3x6BS M3x6BS M3x6BS M3x6
GEN
ERA
L A
CC
ESSO
RIE
S
Cross-connection rails QS for stud terminals HSKCONTA-CONNECT
QS../35
Cross-connection rail
QS 2/3517010.0QS 3/3517011.0
12510006.218
HSK 35/M6 BHSK 35/M6 B/B
Qty.
1
Qty.
1
Qty.
1
Page PageQty. Qty. Qty.
QS cross-connection rail
With neighbouring stud terminals, it is possible to implement potentialdistribution over a two- or three-pole cross-connection. The correspon-ding windows on the TW partition must be slotted out first, in order tomount the cross-connections.
Features:· 2 - and 3-pole versions· Potential distribution between different sizes is also possible· Designed for the rated current of the corresponding stud terminal· Clearly saves time with quick potential distribution
TypeType/colourCat. no.Type/colourCat. no.Colours availableRatingsRated current, AMax. voltage, VHole size, mmPitch, mm
AccessoriesType/colourCat. no.Type/colourCat. no.For terminal
QS../50
Cross-connection rail
QS 2/5017012.0QS 3/5017013.0
15010008.223
HSK 50/M8 BHSK 50/M8 B/B
Qty.
Page Page Qty.
Page Qty.
Page
Qty.
1
1
Qty.
1
1
Qty.
1
1
QS../16
Cross-connection rail
QS 2/1617008.0QS 3/1617009.0
7610005.215
HSK 16/M5 B
2 poles
3 poles
2 poles
3 poles
QS cross-connection rail
With neighbouring stud terminals, it is possible to implement potentialdistribution over two-pole QS cross-connection rails. The cross-connec-tions are each designed for the rated current of the terminal. They aresimply placed together with the cable lug over the stud. When using thecross-connection rails, do not use the partitions between the individualterminals. A cover over the terminals is not possible here.
Features:· 2-pole version· Designed for the rated current of the corresponding stud terminal· Clearly saves time with quick potential distribution
TypeType/colourCat. no.Type/colourCat. no.Colours availableRatingsRated current, AMax. voltage, VHole size, mmPitch, mm
AccessoriesType/colourCat. no.Type/colourCat. no.For terminal
QS 2
Cross-connection rail
QS 22410.0
7610008.215
HSK 70/BHSK 70 B/B
QS 2
Cross-connection rail
QS 22411.0
192100010.240
HSK 95 BHSK 95 B/B
QS 2
Cross-connection rail
QS 22412.0
232100012.640
HSK 150 BHSK 150 B/B
298
Qty.
Qty.
Qty.
Qty.
Qty.Page
Qty.
1
Page Qty. Page Qty.
Remarks Remarks Remarks Remarks Remarks
Page Qty.
Page Qty.Page Qty.
Qty.
1
1
Qty.
1
1
Qty.Qty.
1
Qty.
1
QS../120
Cross-connection rail
QS 2/120/1017014.0QS 3/120/1017015.0
269100010.234
HSK 120/M10 BHSK 120/M10 B/B
QS../120
Cross-connection rail
QS 2/120/1217016.0QS 3/120/1217017.0
269100012.234
HSK 120/M12 BHSK 120/M12 B/B
QS 2 HSK 35/M6 - M8
Cross-connection rail M6 to M8
QS 2 HSK 35/M6 - M817028.2
1501000
1 x 6.2 - 1 x 8.2-
HSK 35/M6 BHSK 35/M6 B/B
QS 3 HSK 35/M6 - M10/2
Cross-connection rail M6 to M10
QS 3 HSK 35/M6 - M10/217029.2
2691000
1 x 6.2 - 2 x 10.2-
HSK 35/M6 BHSK 35/M6 B/B
QS 2
Cross-connection rail
QS 22413.0
309100016.250
HSK 240 BHSK 240 B/B
299
GEN
ERA
L A
CC
ESSO
RIE
S
CONTA-CONNECT
300
Insulated cross-connections FQI (potential distribution)
The FQI pluggable cross-connection system helps you to save time while distributingpotentials over terminal blocks of similar or different cross-sections. The pluggabledesign of the FQI offers the advantage that it can carry the rated current even whileoperating at the rated voltage of 800 V! The FQI is constructed to protect againstaccidental touch. It is available in 2 – 10 poles.
Parallel connections between various potentials, without lossof poles, is possible in the 1.5 mm2, 2.5 mm2 and 4 mm2
cross-section ranges.
With the standard terminal blocks, it is possible to skip overterminal blocks by breaking out individual contact poles.
The disconnected contact elements can be labelled by usingthe plastic insulation from the cross-connection.
It is possible to shorten the cross-connection with a cuttingtool, but you must then make sure that the cut side is fittedwith an end plate so that the voltage rating is maintained.For standard terminal blocks in the cross-sections 1.5 mm2
2.5 mm2 and 4 mm2, it is adequate to attach the FQIs in anoffset position (two cross-connection channels).
In order to help distinguish between different potentials, oth-er colour variants are available for the FQI 1,5, FQI 2,5 andFQI 4 cross-connectors!
300
✘ ✔
301
Insulated cross-connections FQI (potential distribution)
Usage of the FQI
Cross-connection options
Simple Side-by-side Alternating
Parallel alternating Parallel extended Chain linked
GEN
ERA
L A
CC
ESSO
RIE
S
Insulated cross-connections FQICONTA-CONNECT
Cross-connections FQI
The FQI cross-connections for the FRK pressure-springconnection system have a pluggable, insulated design.They can be used to conduct the rated current of the cor-responding cross-section range.
The terminal block design and the variability of the cross-connector ensure excellent flexibility.
TypeType/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.
Colours availableRatingsRated current, AMax. voltage with partition plate, VMax. voltage without partition plate, VRated impulse voltage, kV | Contamination degreePitch, mm
Connection data
Accessories
For terminal
FQI 1,5...
FQI 1,5/2 YE3452.8FQI 1,5/3 YE3453.8FQI 1,5/4 YE3454.8FQI 1,5/5 YE3455.8FQI 1,5/6 YE3456.8FQI 1,5/7 YE3457.8FQI 1,5/8 YE3458.8FQI 1,5/9 YE3459.8FQI 1,5/10 YE3450.8
IEC17.5800800- |34
FRK 1,5...FSL 1,5...
FQI 2,5...
FQI 2,5/2 YE3462.8FQI 2,5/3 YE3463.8FQI 2,5/4 YE3464.8FQI 2,5/5 YE3465.8FQI 2,5/6 YE3466.8FQI 2,5/7 YE3467.8FQI 2,5/8 YE3468.8FQI 2,5/9 YE3469.8FQI 2,5/10 YE3460.8
IEC24
800800- |35
FRK 2,5...FSL 2,5...FRKD 2,5...FSLD 2,5...FTRK 2,5...
FQI 2,5-4...
FQI 2,5-4/2 YE3492.8FQI 2,5-4/3 YE3493.8FQI 2,5-4/4 YE3494.8FQI 2,5-4/5 YE3495.8FQI 2,5-4/6 YE3496.8FQI 2,5-4/7 YE3497.8FQI 2,5-4/8 YE3498.8FQI 2,5-4/9 YE3499.8FQI 2,5-4/10 YE3490.8
IEC32
800800- |35
FDLIS 2,5-4...
2 poles
3 poles
4 poles
5 poles
6 poles
7 poles
8 poles
9 poles
10 poles
Qty.
50
50
20
20
20
20
10
10
10
Qty.
50
50
20
20
20
20
10
10
10
Qty.
50
50
20
20
20
20
10
10
10
Qty.
Remarks Remarks Remarks
Page Qty.Page Qty.Page
Cross-connection insulated
Cross-connection insulated
Cross-connection insulated
.9.8.5.4 .9.8.5.4 .8
302
Cross-connection insulated
FQI 4...
FQI 4/2 YE3472.8FQI 4/3 YE3473.8FQI 4/4 YE3474.8FQI 4/5 YE3475.8FQI 4/6 YE3476.8FQI 4/7 YE3477.8FQI 4/8 YE3478.8FQI 4/9 YE3479.8FQI 4/10 YE3470.8
IEC32
800800- |36
FRK 4...FSL 4...
Qty.
50
50
20
20
20
20
10
10
10
Qty.
Remarks
Page
.9.8.5.4
303
Outlet through
FRK 1,5/2A (3200...)FRK 1,5/3A (3201...)FRK 1,5/4A (3202...)FRK 2,5/2A (3210...)FRK 2,5/3A (3211...)FRK 2,5/4A (3212...)FRK 4/2A (3220...)FRK 4/3A (3221...)FRK 4/4A (3222...)FRK 1,5/2A (3200...)FRK 1,5/3A (3201...)FRK 1,5/4A (3202...)FRK 2,5/2A (3210...)FRK 2,5/3A (3211...)FRK 2,5/4A (3212...)FRK 4/2A (3220...)FRK 4/3A (3221...)FRK 4/4A (3222...)FRK 1,5/2A (3200...)FRK 1,5/3A (3201...)FRK 1,5/4A (3202...)FRK 2,5/2A (3210...)FRK 2,5/3A (3211...)FRK 2,5/4A (3212...)FRK 4/2A (3220...)FRK 4/3A (3221...)FRK 4/4A (3222...)FRK 1,5/2A (3200...)FRK 1,5/3A (3201...)FRK 1,5/4A (3202...)FRK 2,5/2A (3210...)FRK 2,5/3A (3211...)FRK 2,5/4A (3212...)FRK 4/2A (3220...)FRK 4/3A (3221...)FRK 4/4A (3222...)FRK 1,5/2A (3200...)FRK 1,5/3A (3201...)FRK 1,5/4A (3202...)FRK 2,5/2A (3210...)FRK 2,5/3A (3211...)FRK 2,5/4A (3212...)FRK 4/2A (3220...)FRK 4/3A (3221...)FRK 4/4A (3222...)FRK 1,5/2A (3200...)FRK 1,5/3A (3201...)FRK 1,5/4A (3202...)FRK 2,5/2A (3210...)FRK 2,5/3A (3211...)FRK 2,5/4A (3212...)FRK 4/2A (3220...)FRK 4/3A (3221...)FRK 4/4A (3222...)FRK 1,5/2A (3200...)FRK 1,5/3A (3201...)FRK 1,5/4A (3202...)FRK 2,5/2A (3210...)FRK 2,5/3A (3211...)FRK 2,5/4A (3212...)FRK 4/2A (3220...)FRK 4/3A (3221...)FRK 4/4A (3222...)FRK 1,5/2A (3200...)FRK 1,5/3A (3201...)FRK 1,5/4A (3202...)FRK 2,5/2A (3210...)FRK 2,5/3A (3211...)FRK 2,5/4A (3212...)FRK 4/2A (3220...)FRK 4/3A (3221...)FRK 4/4A (3222...)FRK 1,5/2A (3200...)FRK 1,5/3A (3201...)FRK 1,5/4A (3202...)FRK 2,5/2A (3210...)FRK 2,5/3A (3211...)FRK 2,5/4A (3212...)FRK 4/2A (3220...)FRK 4/3A (3221...)FRK 4/4A (3222...)
Feed on left start
FQI 1,5/...FQI 1,5/...FQI 1,5/...FQI 1,5/2FQI 1,5/2FQI 1,5/2not possiblenot possiblenot possiblenot possibleFQI 1,5/...FQI 1,5/...not possibleFQI 1,5/2FQI 1,5/2not possiblenot possiblenot possiblenot possiblenot possibleFQI 1,5/...not possiblenot possibleFQI 1,5/2not possiblenot possiblenot possibleFQI 1,5/...FQI 1,5/...FQI 1,5/...FQI 2,5/...FQI 2,5/...FQI 2,5/...FQI 2,5/2FQI 2,5/2FQI 2,5/2not possibleFQI 1,5/...FQI 1,5/...not possibleFQI 2,5/...FQI 2,5/...not possibleFQI 2,5/2FQI 2,5/2not possiblenot possibleFQI 1,5/...not possiblenot possibleFQI 2,5/...not possiblenot possibleFQI 2,5/2not possiblenot possiblenot possibleFQI 2,5/...FQI 2,5/...FQI 2,5/...FQI 4/...FQI 4/...FQI 4/...not possiblenot possiblenot possiblenot possibleFQI 2,5/...FQI 2,5/...not possibleFQI 4/...FQI 4/...not possiblenot possiblenot possiblenot possiblenot possibleFQI 2,5/...not possiblenot possibleFQI 4/...
Feed on right end
FQI 1,5/...not possiblenot possibleFQI 1,5/2not possiblenot possiblenot possiblenot possiblenot possibleFQI 1,5/...FQI 1,5/...not possibleFQI 1,5/2FQI 1,5/2not possiblenot possiblenot possiblenot possibleFQI 1,5/...FQI 1,5/...FQI 1,5/...FQI 1,5/2FQI 1,5/2FQI 1,5/2not possiblenot possiblenot possibleFQI 1,5/...not possiblenot possibleFQI 2,5/...not possiblenot possibleFQI 2,5/2not possiblenot possibleFQI 1,5/...FQI 1,5/...not possibleFQI 2,5/...FQI 2,5/...not possibleFQI 2,5/2FQI 2,5/2not possibleFQI 1,5/...FQI 1,5/...FQI 1,5/...FQI 2,5/...FQI 2,5/...FQI 2,5/...FQI 2,5/2FQI 2,5/2FQI 2,5/2not possiblenot possiblenot possibleFQI 2,5/...not possiblenot possibleFQI 4/...not possiblenot possiblenot possiblenot possiblenot possibleFQI 2,5/...FQI 2,5/...not possibleFQI 4/...FQI 4/...not possiblenot possiblenot possiblenot possibleFQI 2,5/...FQI 2,5/...FQI 2,5/...FQI 4/...FQI 4/...FQI 4/...
Feed-in through
FRK 1,5/2A (3200...)
FRK 1,5/3A (3201...)
FRK 1,5/4A (3202...)
FRK 2,5/2A (3210...)
FRK 2,5/3A (3211...)
FRK 2,5/4A (3212...)
FRK 4/2A (3220...)
FRK 4/3A (3221...)
FRK 4/4A (3222...)
Cross-connections FQI (feeding potentials)The FQI pluggable cross-connection system helps you to save time while distributingpotentials over terminal blocks of similar or different cross-sections.
GEN
ERA
L A
CC
ESSO
RIE
S
304304
Insulated cross-connections ZQI (potential distribution)
CONTA-CONNECT
304
Parallel connections between various potential, without loss of poles, ispossible in the 2.5 mm2 and 4 mm2 cross-section ranges.
With the standard terminal blocks, it is possible to skip over terminalblocks by breaking out individual contact poles.
It is possible to shorten the cross-connection with a cutting tool, but youmust then make sure that the cut side is fitted with an end plate so thatthe voltage rating is maintained. For standard terminal blocks in the cross-sections 2.5 mm2 and 4 mm2, it is adequate to attach the ZQIs in an offsetposition (two cross-connection channels).
In the 10 mm2 and 16 mm2 cross-sections, cross-connections larger thantwo poles are implemented using the corresponding ZQI/.../2 togetherwith a chain link.
Important note:Do not deform the shape of the ZQIs (do not take apart or press togeth-er).
In order to help distinguish between different potentials, other colourvariants are available for the ZQI 2,5 and ZQI 4 cross-connectors!
The ZQI pluggable cross-connection system helps you to save time whiledistributing potentials over terminal blocks of similar or different cross-sec-tion ranges. The pluggable design of the ZQI offers the advantage that itcan carry the rated current even while operating at the rated voltage! TheZQI is constructed to protect against accidental touch. It is available in 2 – 10 poles. It is available with up to 99 poles in the 2 mm2 cross-sectionrange.
305305305
Insulated cross-connections ZQI (potential distribution)
Usage of ZQI
Cross-connection options
Simple Side-by-side Alternating
Parallel alternating Parallel extended Chain linked
Overview of cross-connections available with tension-spring connection systemThe cross-connections listed here can be used to connect upto twenty terminals blocks with each other. This flexible sys-tem helps you to save time during installation and thus alsosave money. The ZQI 2,5/99 is a many-pole pluggable cross-connectorfor all tension-spring terminals with rated cross-sections of2.5 mm2. There is a captive connection between the insula-tion and the crest. The ZQI 2,5/99 covers 99 poles. A suit-able cutting tool can be used to shorten it to the requiredpole length.
The ZVQI 2,5 vertical cross-connector provides a pluggableelectrical connection between the levels of the ZRKD andZIKD. When a vertical connector is inserted, it is still possibleto make a cross-connection to the neighbouring terminalblocks.
Insulated external cross-connectorExternal cross-connection bridges make it possible to branchoff the potential for terminals which are not available in themiddle of the terminal via a cross-connection channel. Whenexternal cross-connections are used, the rated cross-section isreduced to the next smallest wire size.
Cross-connections ZQI | Vertical connector ZVQI | External insulated cross-connector AQI
GEN
ERA
L A
CC
ESSO
RIE
S
✘ ✔
306306
Cross-connections ZQI (feeding potentials)
CONTA-CONNECT
306
It is possible to cross-connect large cross-section terminals tosmaller ones. This allows for a simple distribution among dif-ferent potential levels and cross-section levels.
The ZQI pluggable cross-connection system helps you tosave time while distributing potentials over terminal blocks ofsimilar or different cross-section ranges.
307307
Cross-connections ZQI (potential distribution)
307
Feed-in with
ZRK 2,5/2A (3500...)
ZRK 2,5/3A (3501...)
ZRK 2,5/4A (3502...)
ZRK 4/2A (3515...)
ZRK 4/3A (3516...)
ZRK 4/4A (3517...)
ZRK 6/2A (3581...)
ZRK 10/2A (3597...)
ZRK 16/2A (3636...)
Outlet through
ZRK 2,5/2A (3500...)ZRK 2,5/3A (3501...)ZRK 2,5/4A (3502...)ZRK 4/2A (3515...)ZRK 4/3A (3516...)ZRK 4/4A (3517...)ZRK 6/2A (3581...)ZRK 2,5/2A (3500...)ZRK 2,5/3A (3501...)ZRK 2,5/4A (3502...)ZRK 4/2A (3515...)ZRK 4/3A (3516...)ZRK 4/4A (3517...)ZRK 6/2A (3581...)ZRK 2,5/2A (3500...)ZRK 2,5/3A (3501...)ZRK 2,5/4A (3502...)ZRK 4/2A (3515...)ZRK 4/3A (3516...)ZRK 4/4A (3517...)ZRK 6/2A (3581...)ZRK 2,5/2A (3500...)ZRK 2,5/3A (3501...)ZRK 2,5/4A (3502...)ZRK 4/2A (3515...)ZRK 4/3A (3516...)ZRK 4/4A (3517...)ZRK 6/2A (3581...)ZRK 2,5/2A (3500...)ZRK 2,5/3A (3501...)ZRK 2,5/4A (3502...)ZRK 4/2A (3515...)ZRK 4/3A (3516...)ZRK 4/4A (3517...)ZRK 6/2A (3581...)ZRK 2,5/2A (3500...)ZRK 2,5/3A (3501...)ZRK 2,5/4A (3502...)ZRK 4/2A (3515...)ZRK 4/3A (3516...)ZRK 4/4A (3517...)ZRK 6/2A (3581...)ZRK 2,5/2A (3500...)ZRK 2,5/3A (3501...)ZRK 2,5/4A (3502...)ZRK 4/2A (3515...)ZRK 4/3A (3516...)ZRK 4/4A (3517...)ZRK 6/2A (3581...)ZRK 2,5/2A (3500...)ZRK 2,5/3A (3501...)ZRK 2,5/4A (3502...)ZRK 4/2A (3515...)ZRK 4/3A (3516...)ZRK 4/4A (3517...)ZRK 6/2A (3581...)ZRK 10/2A (3597...)ZRK 2,5/2A (3500...)ZRK 2,5/3A (3501...)ZRK 2,5/4A (3502...)ZRK 4/2A (3515...)ZRK 4/3A (3516...)ZRK 4/4A (3517...)ZRK 6/2A (3581...)ZRK 10/2A (3597...)ZRK 16/2A (3636...)
Feed on left start
ZQI 2,5/...ZQI 2,5/...ZQI 2,5/...ZQI 4/...ZQI 4/...ZQI 4/...ZQI 4/2not possibleZQI 2,5/...ZQI 2,5/...not possibleZQI 4/...ZQI 4/...not possiblenot possiblenot possibleZQI 2,5/...not possiblenot possibleZQI 4/...not possibleZQI 2,5/...ZQI 2,5/...ZQI 2,5/...ZQI 4/...ZQI 4/...ZQI 4/...ZQI 4/2not possibleZQI 2,5/...ZQI 2,5/...not possibleZQI 4/...ZQI 4/...not possiblenot possiblenot possibleZQI 2,5/...not possiblenot possibleZQI 4/...not possibleZQI 2,5/...ZQI 2,5/...ZQI 2,5/...ZQI 4/...ZQI 4/...ZQI 4/...ZQI 6/...not possiblenot possiblenot possiblenot possiblenot possiblenot possibleZQI 6/...ZQI 10/2not possiblenot possiblenot possiblenot possiblenot possiblenot possibleZQI 6/...ZQI 10/2ZQI 16/2
Feed on right end
not possiblenot possibleZQI 2,5/2not possiblenot possibleZQI 4/2ZQI 2,5/...ZQI 2,5/...not possibleZQI 2,5/2ZQI 2,5/2not possibleZQI 4/2ZQI 2,5/...ZQI 2,5/...ZQI 2,5/...ZQI 2,5/2ZQI 2,5/2ZQI 2,5/2ZQI 4/2
ZQI 4/2not possiblenot possibleZQI 4/...not possiblenot possibleZQI 4/2ZQI 4/2ZQI 4/2not possibleZQI 4/...ZQI 4/...not possibleZQI 4/2ZQI 4/2ZQI 4/2ZQI 4/2ZQI 4/...ZQI 4/...ZQI 4/...ZQI 4/2ZQI 4/2not possiblenot possibleZQI 4/...not possiblenot possibleZQI6,0/...ZQI 2,5/... Remove second contact element on each!
ZQI 2,5/... Remove second contact element on each!
ZQI 2,5/... Remove second contact element on each!
not possiblenot possiblenot possibleZQI 6.0/...ZQI 10/2ZQI 2,5/... Remove second contact element on each!
ZQI 2,5/... Remove second contact element on each!
ZQI 2,5/... Remove second contact element on each!
ZQI 4/... Remove second contact element on each!
ZQI 4/... Remove second contact element on each!
ZQI 4/... Remove second contact element on each!
ZQI 10/2ZQI 16/2ZQI 16/2
The ZQI pluggable cross-connection system helps you to save time while distributing potentials over terminal blocks of similar or different cross-sec-tion ranges.
GEN
ERA
L A
CC
ESSO
RIE
S
Insulated cross-connections ZQI/AQI/ZVQICONTA-CONNECT
Cross-connections ZQI | AQI | ZVQI
The cross-connections for the ZRK tension-spring connec-tion system have a pluggable, insulated design. They canbe used to conduct the rated current of the correspondingcross-section range.
The terminal block design and the variability of the cross-connector ensure excellent flexibility.
TypeType/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.
Colours availableRatingsRated current, AMax. voltage with partition plate, VMax. voltage without partition plate, VRated impulse voltage, kV | Contamination degreePitch, mm
Connection data
Accessories
For terminal
ZQI 2,5...
ZQI 2,5/2 YE3710.8ZQI 2,5/3 YE3711.8ZQI 2,5/4 YE3712.8ZQI 2,5/5 YE3713.8ZQI 2,5/6 YE3714.8ZQI 2,5/7 YE3715.8ZQI 2,5/8 YE3716.8ZQI 2,5/9 YE3717.8ZQI 2,5/10 YE3718.8
IEC24
800800- |35
ZSRK 2,5...ZRK 2,5...ZRKD 2,5ZIKD 2,5ZTRK 2,5ZIZA 1,5RK 2,5/35N 2Q
ZQI 2,5/99
ZQI 2,5/0.5 w/99 poles YE3719.8
IEC24
800800- |35
ZSRK 2,5...ZRK 2,5...ZRKD 2,5ZIKD 2,5ZTRK 2,5ZIZA 1,5RK 2,5/35N 2Q
ZQI 4
ZQI 4/2 YE3720.8ZQI 4/3 YE3721.8ZQI 4/4 YE3722.8ZQI 4/5 YE3723.8ZQI 4/6 YE3724.8ZQI 4/7 YE3725.8ZQI 4/8 YE3726.8ZQI 4/9 YE3727.8ZQI 4/10 YE3728.8
IEC32
800800- |36
ZRK 4...ZRK 4...
2 poles
3 poles
4 poles
5 poles
6 poles
7 poles
8 poles
9 poles
10 poles
99 poles
Qty.
50
50
20
20
20
20
10
10
10
Qty.
1
Qty.
50
50
20
20
20
20
10
10
10
Qty.
Remarks Remarks Remarks
Page Qty.Page Qty.Page
Cross-connection insulated
Cross-connection insulated
Cross-connection insulated
.9.8.5.4 .9.8.5.4 .9.8.5.4
308
Cross-connection insulated
Cross-connection insulated
Cross-connection insulated
ZQI 10
ZQI 10/2 YE3789.8
IEC57
800800- |310
ZRK 10...
Qty.
20
Remarks
Qty.Page
ZQI 16
ZQI 16/2 YE3800.8
IEC75
10001000- |312
ZRK 16...
Qty.
20
Remarks
Qty.Page
AQI.../5/15
AQI 2/5/15 YE2023.0AQI 3/5/15 YE2024.0AQI 4/5/15 2028.0
AQI 10/5/15 2029.0
IEC24
- |3
ZSRK 2,5...ZRK 2,5...ZRKD 2,5ZIKD 2,5ZTRK 2,5ZIZA 1,5
Qty.
50
50
10
10
Remarks
Qty.Page
ZVQI 2,5
ZVQI 2,5 OG3472.8ZVQI 2,5 OG3744.2
IEC24
800800
|3
ZRKD 2,5ZIKD 2,5
Qty.
20
Remarks
Qty.Page
ZQI 6...
ZQI 6/2 YE3763.8ZQI 6/3 YE3764.8ZQI 6/4 YE3765.8ZQI 6/5 YE3766.8ZQI 6/6 YE3767.8ZQI 6/7 YE3768.8ZQI 6/8 YE3769.8ZQI 6/9 YE3470.8ZQI 6/10 YE3471.8
IEC41
800800- |38
ZRK 6...
Qty.
50
50
20
20
20
20
10
10
10
Qty.
Remarks
Page
External cross-connection insulated
Vertical connector insulated
.9.8.5.4
309
GEN
ERA
L A
CC
ESSO
RIE
S
Individual covers EA| Individual and four-way covers ADCONTA-CONNECT
Individual covers EA | Individual and four-way covers ADVDE regulations require that the mains terminals be covered. The EAand AD yellow covers (labelled with a lightning flash) are used to coverthe operational channel and the cross-connection channel of the termi-nal. Thus they discourage operation of the terminal while live voltage ispresent. The EA 1 and AD 1 covers are snapped down on the terminalblocks. The BS 1 marker pen or the EMS labelling system can be usedto label the white variants. The AD 4, which is designed for four termi-nals of the corresponding cross-section size, is mechanically attachedusing two plastic screws. Two print variants (German and English(.../E)) are available.
TypeType/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.
Colours availableRatingsWidth, mm
Labelling
AccessoriesType/colourCat. no.Type/colourCat. no.For terminal
Qty.
50
50
50
50
50
50
Qty.
500
Remarks Remarks
Page
339
Qty.Page Qty.Page
Individual cover, blank /Individual cover, with light-
ning flash symbol
Individual cover, blank /Individual cover, withlightning flash symbol
Individual cover, blank /Individual cover, withlightning flash symbol
.2 .7 .8
Blank
Blank
Blank
Lightning flash
Lightning flash
Lightning flash
Blank
Blank
Lightning flash
Lightning flash
Blank
Lightning flash
Qty.
50
50
50
50
Qty.
50
50
EA 1...
EA 1 BG2703.2EA 1 WH2703.7EA 1 YE2703.8EA 1/B BG2803.2EA 1/B WH2803.7EA 1/B YE2803.8
5
BlankB lightning flash
PMC SB/50 WH4600.7
RK 2,5RK 2,5-4RK 6-10RK 2,5-4 ZRRK 2,5-4 ZRLFF 2.5SF 2,5-4SL 2,5SL 4SL 10SRK 2,5/2ASSL 2,5/2A
AD 1/5
AD 1/5 WH2962.0AD 1/5/N WH2963.0
AD 1/5/B YE2952.0AD 1/5/N/B YE2964.0
5
BlankB lightning flash
RK 2,5KBL 2,5RK 2,5 N 2QSRK 2,5/2ASSL 2,5/2A
AD 1/6
AD 1/6 WH2965.0
AD 1/6/B YE2953.0
6
BlankB lightning flash
RK 2,5-4KBL 2.5-4SRK 4/2ASSL 4/2A
RemarksAD 1/5AD 1/5
A/D 1/5 N
310
AD 1/12
AD 1/12 WH2969.0AD 1/12/N WH2967.0
AD 1/12/B YE2819.0AD 1/12/N/B YE2955.0
12
BlankB lightning flash
RK 16RK 16/35 N
RemarksAD 1/12
A/D 1/12 N
Qty.Page
AD 1/16
AD 1/16 WH2970.0AD 1/16/N WH2968.0
AD 1/16/B YE2820.0AD 1/16/N/B YE2956.0
16
BlankB lightning flash
RK 35RK 35/35 N
AD/1/50...AD 1/240
AD 1/50/B YE 2810.0AD 1/95/B YE 2804.0AD 1/150/B YE 2806.0AD 1/240/B YE2808.0
20, 25, 31, 36
B lightning flash
RK 50RK 95RK 150RK 240
RemarksAD 1/50 B
A/D 1/95 BAD 1/150 B
A/D 1/240 B
Qty.Page
AD 4
AD 4/20/B YE2712.0AD 4/24/B YE2079.0AD 4/24/B YE2011.0AD 4/32/B YE2054.0AD 4/24/BE YE2493.0AD 4/24/BE YE2494.0AD 4/24/BE YE2713.0AD 4/32/BE YE2495.0
RK 2,5KBL 2,5
RK 1,5-4RKD 4KBL 1,5-4KBLD 4RK 2,5-4KBL 2.5-4
RK 6-10KBL 6-10
ADAD 4/20...2712.02713.0
AD 4/24...2079.02493.0
AD 4/24...2011.02494.0
AD 4/32...2054.02495.0
Qty.
100
100
AD 1/8
AD 1/8 WH2966.0
AD 1/8/B YE2954.0
8
BlankB lightning flash
RK 6-10KBL 6-10SRK 6/2ASSL 6/2ASRK 10/2ASSL 10/2A
Qty.
Remarks
Page
Individual cover, blank /Individual cover, withlightning flash symbol
Individual cover, blank /Individual cover, with light-
ning flash symbol
Individual cover, with light-ning flash symbol
Four-way cover with light-ning flash
Individual cover, blank /Individual cover, with light-
ning flash symbol
Blank
Lightning flash
Blank
Blank
Lightning flash
Lightning flash
Blank
Blank
Lightning flash
Lightning flash
Lightning flash
Lightning flash
Lightning flash
Lightning flash
Blank
Blank
Blank
Lightning flash
Lightning flash
Lightning flash
Lightning flash
Lightning flash
Qty.
50
50
Qty.
20
20
20
20
Qty.
20
20
20
20
Qty.
20
20
20
20
Qty.
50
50
50
50
50
50
50
50
“Vorsicht Spannung” and lightning flash
E “Attention Voltage” and lightning flash
Qty.Page ScrewBSK M 2,5x22 BK
2080.0BSK M 3x22 BK2012.0
ScrewM 2,5
M 2.5
M 3
M3
RemarksAD 1/16
A/D 1/16 N
311
GEN
ERA
L A
CC
ESSO
RIE
S
.8
Individual covers AD | Protective hoods AHCONTA-CONNECT
Individual covers AD
The AD covers can snapped on, simply and securely, to the matching
clips in the TW partitions. In this quick and reliable way, touch-safe pro-
tection of the terminal points is always guaranteed.
TypeType/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.
Colours availableRatingsWidth, mmLength, mmMaterial
Labelling
AccessoriesType/colourCat. no.Type/colourCat. no.For terminal
Qty.
20
Qty.
20
20
Qty.
20
20
Page
316
Page
316
316
Page
316
316
Individual cover Individual cover Individual cover
.8 .8 .8
312
AD 35
AD 35 YE17020.8
1671
PA 6.6 V0
TW 16-120 BG17018.2TW 35-120/B/B BG17022.2
HSK 35/M6 BHSK 35/M6 B/B
AD 50
AD 50 YE17021.8
2176
PA 6.6 V0
TW 16-120 BG17018.2TW 35-120/B/B BG17022.2
HSK 50/M8 BHSK 50/M8 B/B
AD 16
AD 16 YE17019.8
1353
PA 6.6 V0
TW 16-120 BG17018.2
HSK 16/M5 B
Qty.
20
Qty.
20
Qty.
20
Individual cover
Page
316
.8
313
AD 120
AD 120 YE17026.8
32158
PA 6.6 V0
TW 35-120 BG17022.2
HSK 120/M10 BHSK 120/M12 BHSK 120/M10 B/B
Qty.
20
Qty.
20
Protective hood
Page
316
AH 40
AH 40 transparent2381.0
40
Polycarbonate
TW 97 BG2380.0BS AD/M 2,9x6,52385.0
HSK 70/35 BHSK 70/35 B/BHSK 95/35 BHSK 95/35 B/B
Qty.
1
100
Qty.
1
Protective hood
Page
316
AH 50
AH 50 transparent2382.0
50
Polycarbonate
TW 138 BG1178.0BS AD/M 2,9x6,52385.0
HSK 150/35 BHSK 150/35 B/BHSK 240/35 BHSK 240/35 B/B
Qty.
1
100
Qty.
1
Protective hood AH
The transparent AH covers offer a simple and safe method for protecting
terminals and wires from accidental touch. They are securely screwed
into the flanges built into the TW partition plates.
TypeType/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.
Colours availableRatingsWidth, mm
Material
labelling
AccessoriesType/colourCat. no.Type/colourCat. no.For terminal
GEN
ERA
L A
CC
ESSO
RIE
S
Four-way covers FAD/ZADCONTA-CONNECT
Qty.
20
Qty.
Page
Qty.
20
Qty.
20
Qty.
50
Qty.
20
Qty.
50
Page PageQty.
Qty.
Remarks Remarks Remarks
Remarks Remarks Remarks
FAD 1,5
Four-way cover withLightning flash
FAD 1,5/4/B YE3425.8
4.1PA 6.6 V0
FRK 1,5...FSL 1.5...
FBA 1
Labelling adapter for double-level terminals
FBA 1 BG3424.2
5.1PA 6.6 V0
PMC SB/50 WH4600.7
FRKD 2,5...
FAD 2.5
Four-way cover withLightning flash
FAD 2,5/4/B YE3426.8
5.1PA 6.6 V0
FRK 2,5...FSL 2,5...FRKD 2,5...FSLD 2,5...FDLIS 2,5-4...FTRK2,5...
ZBA 1
Labelling adapter for double-level terminals
ZBA 1 BG3745.2
5.1PA 6.6 V0
PMC SB/50 WH4600.7
ZRKD 2,5...
FAD 4
Four-way cover withlighting flash
FAD 4/4/B YE3427.8
6.1PA 6.6 V0
FRK 4...FSL 4...
ZBA 3
Labelling adapter for multi-level terminals
ZBA 3 BG3813.2
5.1PA 6.6 V0
PMC SB/50 WH4600.7
ZIKD 2,5...-
.8 .8 .8
Page
339
Qty.
500
Page
339
Qty.
500
Page
339
Qty.
500
314
Four-way covers FAD | ZAD
VDE regulations require that the mains terminals be cov-ered.The yellow FAD/ZAD covers (labelled with a lightningflash) are used to cover the operational channel. Thusthey discourage operation of the terminal while live volt-age is present.
TypeType/colourCat. no.Type/colourCat. no.Colours availableRatingsPitch, mmMaterial
Connection data
AccessoriesType/colourCat. no.For terminal
Labelling adapter FBA | ZBAPressure-spring connection system | Tension-spring connection system
TypeType/colourCat. no.
Colours availableRatingsPitch, mmMaterial
Connection data
AccessoriesType/colourCat. no.For terminal
.2 .2 .2
Qty.
20
Qty.
20
Qty.
50
Qty.
50
Qty.
50
Qty.
20
Page Page Page PageQty. Qty. Qty. Qty.
Qty.
20
Remarks Remarks Remarks Remarks
Remarks Remarks Remarks
ZAD 4
Four-way cover withlighting flash
ZAD 4/4/B YE3707.0
6.1PA 6.6 V0
ZRK 4...ZSL 4...
ZBA 2/Z
Labelling adapter forZIZA | ZMP
ZBA 2/Z BG3787.2
5,1PA 6.6 V0
PMC SB/50 WH4600.7
ZIZA 1,5/...ZMP 1,5...
ZAD 16
Four-way cover withLightning flash
ZAD 16/4/B YE3801.0
12PA 6.6 V0
ZRK 16...ZSL 16...
AD Q
Covers Cross-connection channel
AD Q transparent2499.0AD Q white2499.7
6010
RK 2,5-4RK 6-10RK 2,5-4 ZRRK 2,5-4 ZRL
ZAD 2,5
Four-way cover withlighting flash
ZAD 2,5/4/B YE3706.0
5.1PA 6.6 V0
ZSRK 2,5...ZSLN 2,5...ZRK 2,5...ZSL 2,5...ZRKD 2,5...ZSLD 2,5...ZIKD 2,5...ZTRK 2,5...ZVMAK 2,5...ZIZA 1,5...ZBA 2
ZRH 4
Labelling adapter forZIZA | ZMP
ZBA 2 BG3786.2
5,1PA 6.6 V0
PMC SB/50 WH4600.7
ZIZA 1,5/...ZMP 1,5...
ZAD 6
Four-way cover withlighting flash
ZAD 6/4/B YE3708.0
8.1PA 6.6 V0
ZRK 10...ZSL 10...
ZBA 2/Z/H
Labelling adapter forZIZA | ZMP
ZBA 2/Z/H BG17036.2
5,15,1
PA 6.6 V0
PMC SB/50 WH4600.7
ZIZA 1,5/...ZMP 1,5...
.8 .8 .8
Page
339
Qty.
500
Page
339
Qty.
500
Page
339
Qty.
500
315
Qty.
20
Qty.
20
20
Page Qty.
Remarks
FF 2.5SF 2,5-4RK 35
ZAD 10
Four-way cover withlighting flash
ZAD 10/4/B YE3709.0
10.1PA 6.6 V0
ZRK 10...ZSL 10...
Cross-connection channel cover AD
For terminals of types RK 2,5-4,
RK 6-10, RK2,5-4 ZR, RK 2,5-4ZRL, FF 2,5 and SF 2,5-4: 60mm
long covers are available which
can be used to provide touch pro-
tection for uninsulated cross-con-
nections.
The profile section is made from
polyamide 6.6 and is delivered as
either transparent or in white.
TypeType/colourCat. no.
Colours availableRatingsLength, mmWidth, mm
Connection data
AccessoriesType/colourCat. no.For terminal
.8 .8
GEN
ERA
L A
CC
ESSO
RIE
S
.2 .2 .2 .7
CONTA-CONNECT
Specific accessories, pressure-spring connection system (FRK)
End plates / Visual separation
Partition plates TWMF/TW | Cover profile AD | Insulation plate TRS | Connecting sleeves VBS
Cover profile AD combined with partition plates TWMFMany safety requirements (for example, the “Electrical facilities and oper-ating devices” accident prevention regulations (VBG 4) or VDE 0106 part100/3.83) require that the active components of equipment are protect-ed against direct touch. For terminals using Q cross-connectors or test
sockets, this protection is provided by additional covers. Cover profileswith assigned support plates are used for this purpose. They can be usedwith the main terminal sizes. The support plates can be positioned at theend or between groups of terminals. They can be attached to TS 32 orTS 35 rails.
Insulation plate TRSWhen using cross-connections, insulation plates are used for certain terminal types in order to maintain the required creepage and clearance dis-tances. Insulation plates can retroactively be inserted between cross-connectors.
Connecting sleeves VBSConnecting sleeves for coupling two or three hinged levers from the fuse-disconnect terminals STK 2 and SIK 10 or SIK 10 Z and STKD1. The VBSplastic sleeves are pushed on to the sides of the hinged lever. They form a mechanical connection to two-pole or three-pole units. This makes it possi-ble to simultaneously disconnect multi-pole circuits.
Partition plates TWPartition plates must normally be used between uninsulated cross-connectors when making cross-connections.The is required in order to maintain the required creepage and clearance distances.
Cat. no.2957.22957.52957.3
Cat. no.2958.2
Cat. no.2071.22071.5
2002.22002.52002.32002.1
2105.22105.5
2117.22117.5
2426.2
2428.2
2379.0
2380.0
1178.0
17018.2
17022.2
Cat. no.2003.2
2566.2
Cat. no.2873.32874.32875.32876.3
Partition with foot TWMF
AD cover profile
Partition plates TW
Insulation plate TRS
Connecting sleeve VBS
TypeTWMF BGTWMF BUTWMF OG
TypeAD 3/1000 mm
TypeTW 1.5-4 BGTW 1,5-4 BU
TW 2,5-10 BGTW 2,5-10 BUTW 2,5-10 OGTW 2,5-10 GN
TW 16 BGTW 16 BU
TW 35 BGTW 35 BU
TW 2,5 BG
TW 2,5/15 BG
TW 71 BG
TW 97 BG
TW 138 BG
TW 16-120 BG
TW 35-120/B/B BG
TypeTRS 1 BG
TRS 3 BG
TypeVBS 2/10 OGVBS 3/10 OGVBS 2/10/Z OGVBS 3/10/Z OG
Colourbeigeblueorange
Colourtransparent
Colourbeigeblue
beigeblueorangegreen
beigeblue
beigeblue
beige
beige
beige
beige
beige
beige
beige
Colourbeige
beige
Colourorangeorangeorangeorange
Qty.202020
Qty.1
Qty.5050
50505050
2020
2020
50
50
1
1
1
20
20
Qty.100
100
Qty.100100100100
Width2 mm2 mm2 mm
Width1 m
Width1,5 mm1,5 mm
1,5 mm1,5 mm1,5 mm1,5 mm
1,5 mm1,5 mm
1,5 mm1,5 mm
1,5 mm
1,5 mm
2 mm
2 mm
2 mm
2 mm
2 mm
Width
Width16 mm24 mm20 mm30 mm
MaterialPA 6.6 V2PA 6.6 V2PA 6.6 V2
MaterialPolycarbonate
MaterialPA 6.6 V2PA 6.6 V2
PA 6.6 V2PA 6.6 V2PA 6.6 V2PA 6.6 V2
PA 6.6 V2PA 6.6 V2
PA 6.6 V2PA 6.6 V2
PA 6.6 V2
PA 6.6 V2
PA 6.6 V2
PA 6.6 V2
PA 6.6 V2
PA 6.6 V0
PA 6.6 V0
MaterialPA 6.6 V2
PA 6.6 V2
MaterialPA 6.6 V2PA 6.6 V3PA 6.6 V4PA 6.6 V5
Length88 mm88 mm88 mm
Length90 mm
Height incl. TS 35x7.570 mm70 mm70 mm
Height incl. TS 35x7.570 mm
For terminalRK 1,5-4|RK 1,5-4/15|KBL 1,5-4|KBL 1,5-4/15|RKB 4|FF 1/15
RK 2,5|KBL 2,5|RK 2,5-4|RK 6-10|KBL 2,5-4|KBL 6-10|SL 4|SL 4/32|SL 10|SL 10/32|FF 2,5| SF 2,5-4SRK 2,5/2A | SSL 2,5/2A | SRK 4/2A | SSL 4/2A | SRK 6/2A | SSL 6/2A | SRK 10/2A | SSL 10/2A
RK 16
RK 35
SRK 2,5
SRK 2,5/15
HSK 70/35 B/B | HSK 95/35 B/B
HSK 70 B | HSK 95 B | HSK 150/35 B/B | HSK 240/35 B/B
HSK 150 B | HSK 240 B
HSK 16/M5 B | HSK 35/M6 B | HSK 50/M8 B | HSK 120/M10 B | HSK 120/M12 B
HSK 120/M10 B | HSK 120/M12 B | HSK 35/M6 B/B | HSK 50/M8 B/B | HSK 120/M10 B/B
For terminalRK 2,5-4|RK 6-10|RK 16|KBL 2,5-4|KBL 6-10 |PTK
RK 1,5-4/15|KBL 1,5-4/15|RK 2,5|KBL 2,5|RK 1,5-4|KBL 1,5-4RKD 2,5|KBLD 2,5|RKD 4|KBLD 4|DLIS 2,5|DLI 2,5
For terminalSIK 10 | STK 2 / STKD1SIK 10 | STK 2 / STKD1SIK 10/ZSIK 10/Z
316
Specific accessories, pressure-spring connection system (FRK)
End plates / Visual separation
Testing | Inspecting
The PS 2.3 and PS 4 test plugs can be used with screw-connection terminals in cross-sections ranges 2.5 mm2 to 10 mm2. They allow you to con-nect to socket plugs and measure directly on the busbar of the corresponding terminal. In contrast to the TA test adapters, the PS test plugs do notmechanically lock with the terminal. The ZS 2.3/4 adapter plug permits the conversion of a 4-mm Ø plug to a 2.3-mm Ø socket plug.
Test plug PS
TypeType/colourCat. no.When combined with socket plug
PS 2.3
PS 2.32007.0
2075.0 STB 8.5/2.32006.0 STB 14/2.32373.0 STB 62374.0 STB 7
PS 4
PS 42051.0
2050.0 STB 14/42127.0 STB 16/4
ZS 2.3/4
ZS 2.3/42052.0
2075.0 STB 8.5/2.32006.0 STB 14/2.32373.0 STB 62374.0 STB 7
Socket plugs STBThe STB socket plug are attached to the busbar or screwed onto the terminals in place of a terminal screw. They are used for holding the PS test plugs.
Socket plug STB STB
Cat. no.2075.02006.02050.02127.02373.02374.0
TypeSTB 8.5/2.3STB 14/2.3STB 14/4STB 16/4STB 6STB 7
Qty.5050505050
100
L18.514141667
L211.517.5192311.514.5
L3 L4 d12.32.3442.32.3
d2456744
d3 M2.533433
Cat. no.2512.02513.02514.02515.02516.02517.02518.0
TypeSTB 30.5 BKSTB 30.5 GRSTB 30.5 BUSTB 30.5 RDSTB 30.5 GNSTB 30.5 YESTB 30.5 VT
Qty.50505050505050
L130.530.530.530.530.530.530.5
L27777777
L312121212121212
L431.531.531.531.531.531.531.5
d14444444
d26666666
d37.27.27.27.27.27.27.2
M3333333
Socket plug STB 30.5 STB 30.5
Qty.
10
Qty.
20
Qty.
20
317
GEN
ERA
L A
CC
ESSO
RIE
S
Test adapter TA/TADCONTA-CONNECT
Qty.
10
Qty.
500
Page
339
Qty.
10
Qty.
10
TA 5/1N/Q
Test adapter, can be mounted side-by-side
TA 5/1N/Q2811.0
52331
0.5 - 15
PMC SB 5/50 WH4600.7
RK 2,5/35N/2Q
TAD 5/1-S
Test adapter, can be mounted side-by-side
TAD 5/1/S2821.0
5.10.13 - 0.2
77.7
0.5 - 15
PMC SB 5/50 WH4600.7
RKD 2,5
TA 5/1/Q
vTest adapter, can bemounted side-by-side
TA 5/1/Q2823.0
535,537,3
0.5 - 15
PMC SB 5/50 WH4600.7
RK 2,5
TA 5/1/ST
Test adapter, can bemounted side-by-side
TA 5/1/ST2812.0
535,537,3
0.5 - 15
PMC SB 5/50 WH4600.7
RK 2,5
TAD 6/1-S
Test adapter, can bemounted side-by-side
TAD 6/1/S2822.0
6.10.25 - 0.5
77.7
0.5 - 15
PMC SB 6/50 WH4702.7
RKD 4
Qty.
10
Qty.
10
Page
339
Page
339
Qty.
500
Qty.
500Remarks Remarks Remarks
With cross-connection Q
Remarks Remarks
Page
339
Page
340
Qty.
500
Qty.
500
Test adapter TA
The TA test adapters can be assembled to any polecounts using the locking pegs. They can be used to testassembled terminal blocks in a quick and safe manner.Wires with cross-sections ranging from 0.5 mm2 to1.0 mm2 can be crimped or soldered to the spring-loadedtracer pins. Depending on the version, the test adaptersestablish contact with the screw head, the cross-connec-tion or the busbar. The test adapter sets consist of a hous-ing, spring and tracer pin.
TypeType/colourCat. no.
RatingsPitch, mmAdditional height for each terminal block, mmLength, mm
Connection dataFinely stranded, mm2
Stripping length, mmAccessoriesType/colourCat. no.For terminal
Test adaptersTest adapter TAD
An end plate is also included with the TAD versions. All ofthe test adapters can be labelled using the PMC quickmarking system.
TypeType/colourCat. no.
RatingsPitch, mmAdditional height for each terminal block, mmLength, mm
Connection dataFinely stranded, mm2
Stripping length, mmAccessoriesType/colourCat. no.For terminal
318
TA 8/1/Q
vTest adapter, can bemounted side-by-side
TA 8/1/Q2837.0
835.537.3
0.5 - 15
PMC SB 6/50 WH4702.7
RK 6 - 10
Qty.
10
Qty.
10
Qty.
10
TA 6/1/ST
vTest adapter, can bemounted side-by-side
TA 6/1/ST2813.0
635.537.3
0.5 - 15
PMC SB 6/50 WH4702.7
RK 2,5 - 4
Qty.
10
Page
340
Page
340
Page
340
Page
340
Qty.
500
Qty.
500
Qty.
500
Qty.
500Remarks Remarks
With cross-connection QRemarks Remarks
With cross-connection Q
TA 6/1/Q
vTest adapter, can bemounted side-by-side
TA 6/1/Q2824.0
635.537.3
0.5 - 15
PMC SB 6/50 WH4702.7
RK 2,5 - 4
TA 8/1/ST
vTest adapter, can bemounted side-by-side
TA 8/1/ST2817.0
835.537.3
0.5 - 15
PMC SB 6/50 WH4702.7
RK 6 - 10
319
GEN
ERA
L A
CC
ESSO
RIE
S
Test adapter ZTA | Reducing sleeve ZRHCONTA-CONNECT
Qty.
10
Qty.
500
Page
339
Qty.
10
Qty.
10
Qty.
1000
Qty.
1000
Qty.
1000
Page
339
Page
340
Qty.
500
Qty.
500Remarks Remarks Remarks
Remarks Remarks Remarks
Page Page PageQty. Qty. Qty.
Test adapter ZTA
The ZTA test adapters can be assembled to any polecounts using the locking pegs. They can be used to testassembled terminal block strips in a quick and safe man-ner.
Wire cross-sections ranging from 0.5 mm2 to 1.0 mm2 canbe connected. Each tension-clamp terminal has a corre-sponding test point for establishing contact to the poten-tial voltage on the busbar.
TypeType/colourCat. no.
RatingsPitch, mmAdditional height for each terminal block, mmLength, mm
Connection dataFinely stranded, mm2
Stripping length, mmAccessoriesType/colourCat. no.For terminal
Reducing sleeves ZRH
CONTA-CLIP offers reducing sleeves for cross-sections of2.5 mm2 and 4 mm2. This ensures that small wires areproperly positioned in their terminal points without anysplicing off of individual strands. A professional and prop-er contact in ensured when the reducing sleeves areattached prior to the connection.
TypeType/colourCat. no.
RatingsPitch, mmCross-section range, mm2
Connection data
AccessoriesType/colourCat. no.For terminal
ZTA 1,5
Test adapter, can be mounted side-by-side
ZTA 1,517034.2
5.131
32.3
0.5 - 15
PMC SB 5/50 WH4600.7
ZIZA 1.5...
ZRH 2,5
for wires from 0.13 - 0.2 mm2
ZRH 2,5/0,13-0,2 WH3750.7
5.10.13 - 0.2
ZSRK 2,5...ZSLN 2,5...ZRK 2,5...ZSL 2,5...ZRKD 2,5...ZSLD 2,5...ZIKD 2,5...ZTRK 2,5...ZVMAK 2,5...ZIZA 1,5...
ZTA 2.5
Test adapter, can be mounted side-by-side
ZTA 2,53740.2
5.131
32,3
0.5 - 15
PMC SB 5/50 WH4600.7
ZSRK 2,5...ZSLN 2,5...ZRK 2,5...ZSL 2,5...ZRKD 2,5...ZSLD 2,5...ZIKD 2,5...ZTRK 2,5...ZVMAK 2,5...
ZRH 2,5
for wires from 0.25 - 0.5 mm2
ZRH 2,5/0,25-0.5 GR3751.6
5.10.25 - 0.5
ZSRK 2,5...ZSLN 2,5...ZRK 2,5...ZSL 2,5...ZRKD 2,5...ZSLD 2,5...ZIKD 2,5...ZTRK 2,5...ZVMAK 2,5...ZIZA 1,5...
ZTA 4
Test adapter, can be mounted side-by-side
ZTA 43741.2
6.131
32.3
0.5 - 15
PMC SB 6/50 WH4702.7
ZRK 4...ZSL 4...
ZRH 2,5
for wires from 0.75 - 1.0 mm2
ZRH 2.5/0,75-1,0 BK3752.4
5.10.75 - 1
ZSRK 2,5...ZSLN 2,5...ZRK 2,5...ZSL 2,5...ZRKD 2,5...ZSLD 2,5...ZIKD 2,5...ZTRK 2,5...ZVMAK 2,5...ZIZA 1,5...
320
Test plug PS
The PS 2.3 test plugs allowyou to make a direct meas-urement on the test point ofthe corresponding terminalwhen working with tension-spring terminals with cross-sections ranging from 2.5and 4.0 mm2.In contrast to the ZTA, thePS test plug does not snapin mechanically with the ter-minal.
Qty.
10
Qty.
10
Page
Qty.
1000
Qty.
1000
Qty.
1000
Qty.
Qty.
10
Page
340
Page
340
Page
340
PageQty.
500
Qty.
500
Qty.
500
Qty.
Qty.
20
Remarks Remarks Remarks Remarks
Remarks Remarks Remarks
Page Qty.
ZTA 10
vTest adapter, can bemounted side-by-side
ZTA 103790.2
10.131
32.3
0.5 - 15
PMC SB 6/50 WH4702.7
ZRK 10...ZSL 10...
ZRH 4
for wires from 0.25 - 0.5 mm2
ZRH 4/0,25-0.5 GR3754.6
6.10.25 - 0.5
ZRK 4...ZSL 4...
Page Qty.
PS 2.3
Test plug
PS 2.32007.0
5.22232
0.5 - 15
ZSRK 2,5...ZSLN 2,5...ZRK 2,5...ZSL 2,5...ZRKD 2,5...ZSLD 2,5...ZIKD 2,5...ZTRK 2,5...ZVMAK 2,5...
ZIZA 1.5...ZRK 4...ZSL 4...
ZTA 6
vTest adapter, can bemounted side-by-side
ZTA 63772.2
8.131
32.3
0.5 - 15
PMC SB 6/50 WH4702.7
ZRK 6...ZSL 6...
ZRH 4
for wires from 0.13 - 0.2 mm2
ZRH 4/0,13-0,2 WH3753.7
6.10.13 - 0.2
ZRK 4...ZSL 4...
ZTA 16
vTest adapter, can bemounted side-by-side
ZTA 163810.2
1231
32.3
0.5 - 15
PMC SB 6/50 WH4702.7
ZRK 16...ZSL 16...
ZRH 4
for wires from 0.75 - 1.0 mm2
ZRH 4/0,75-1,0 BK3755.4
6.10.75 - 1.0
ZRK 4...ZSL 4...
321
GEN
ERA
L A
CC
ESSO
RIE
S
Fuse holder ZS CONTA-CONNECT
Fuse holder ZS/.../.../ZTRK
The pluggable ZS/.../.../ZTRK fuse holders are availableas versions with or without a status display. When com-bined with the FTRK 2,5 and ZTRK 2,5 base terminals,they provide great flexibility and simple handling.
TypeType/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.
Colours availableRatingsPitch, mmRated voltage, VRated current, AResidual current via LED, mAMax. power loss on fuse, mA
Connection dataFuse size
AccessoriesType/colourCat. no.For terminal
ZS/H0/ZTR
ZS/H0/ZTR3635.2
5.10 - 400
6.3-
1.6
5 x 20
PMC SB 5/50 WH4600.7
ZTRK 2,5...FTRK 2,5...
ZS/H1/ZTR/36
ZS/H1/ZTR/363631.2
5.110 - 36
6.3<51.6
5 x 20
PMC SB 5/50 WH4600.7
ZTRK 2,5...FTRK 2,5...
ZS/H2/ZTR/70
ZS/H2/ZTR/703632.2
5.135 - 70
6.3<51.6
-|-5 x 20
PMC SB 5/50 WH4600.7
ZTRK 2,5...FTRK 2,5...
Qty.
20
Qty.
20
Qty.
20
Qty.
500Remarks Remarks Remarks
Page
339
Qty.
500
Page
339
Qty.
500
Page
339
Fuse holderswithout status display
Fuse holders10-36 V with status display
Fuse holders35-70 V with status display
Coding on fuses
Cat. no.3170.53170.43170.33170.03170.73170.23170.63170.93170.83170.1
TypeCS 0.5 A BUCS 1 A BK CS 2 A GRCS 3 A VT CS 4 A PICS 5 A LBCS 7.5 A BNCS 10 A RDCS 20 A YECS 15 A CY
ColourblueblackgreyvioletpinkbrightbrownbrownredyellowCyan
Qty.100100100100100100100100100100
For terminalZTRK 2,5/...OTZTRK 2,5/...OTZTRK 2,5/...OTZTRK 2,5/...OTZTRK 2,5/...OTZTRK 2,5/...OTZTRK 2,5/...OTZTRK 2,5/...OTZTRK 2,5/...OTZTRK 2,5/...OT
322
ZS/H4/ZTR/250
ZS/H4/ZTR/2503634.2
5.1140 - 250
6.3<51.6
5 x 20
PMC SB 5/50 WH4600.7
ZTRK 2,5...FTRK 2,5...
Qty.
20
Remarks
Qty.
500
Page
339
Disconnect plug
The established disconnect-plug system has a high-quali-ty surfaces and thus minimalcontact resistance. Thisensures precise, unbiasedmeasurement readings. Avariety of components can besoldered into an unpopulatedtest plug.
ZDS.../ZTR
ZDS 1/ZTR 3612.2Disconnect-plug with wire jumper
ZDS 2/ZTR3613.2Disconnect plug with diode
ZDS 3/ZTR 3614.2Disconnect plug with diode
ZDS 4/ZTR3615.2Unpopulated disconnect plug
5.140015
Soldered diode 1N4007
Reverse voltage 1000V / Current 1A
PMC SB 5/50 WH4600.7
ZTRK 2,5...FTRK 2,5...
Qty.
20
20
20
20
Remarks
Qty.
500
Page
339
DS
DS 1/TRK 1,5 YE1400.2Disconnect-plug with wire jumper
DS 2/TRK 1,5 YE1401.2Disconnect plug with diode
DS 3/TRK 1,5 YE1402.2Disconnect plug with diode
DS 4/TRK 1,5 YE1403.2Unpopulated disconnect plug
640015
-|-Soldered diode 1N4007
Reverse voltage 1000V / Current 1A
PMC SB 6/50 WH4702.7
TRK 1,5...
Qty.
1
1
1
1
Remarks
Qty.
500
Page
340
ZS/H3/ZTR/150
ZS/H3/ZTR/1503633.2
5.160 - 150
6.3<51.6
5 x 20
PMC SB 5/50 WH4600.7
ZTRK 2,5...FTRK 2,5...
Qty.
20
Qty.
500Remarks
Page
339
Fuse holders60-150 V with status
display
Fuse holders140-250 V with status
displayDisconnect plug Disconnect plug
323
GEN
ERA
L A
CC
ESSO
RIE
S
CONTA-CONNECT
324324
Cat. no.
2912.02913.02914.02915.02916.02917.02918.02919.02920.02921.02922.02923.02924.02925.02926.02927.02928.02929.02930.02931.02932.02933.02934.02935.02936.02937.0
Rated current,mA/A32 mA40 mA50 mA63 mA80 mA
100 mA125 mA160 mA200 mA250 mA315 mA400 mA500 mA630 mA800 mA
1 A1.25 A1.6 A2 A
2.5 A3.15 A
4 A5 A
6.3 A8 A
10 A
Rated switch-offcap. A AC
35 ‘L’35 ‘L’35 ‘L’35 ‘L’35 ‘L’35 ‘L’35 ‘L’35 ‘L’35 ‘L’35 ‘L’35 ‘L’35 ‘L’35 ‘L’35 ‘L’35 ‘L’35 ‘L’35 ‘L’35 ‘L’35 ‘L’35 ‘L’35 ‘L’40 ‘L’50 ‘L’63 ‘L’80 ‘L’
100 ‘L’
Voltage drop mV
30002000150010008007006006005004001401301201101009080808080808080707070
Power loss, W
0.20.20.20.20.20.30.30.30.30.20.20.20.20.20.30.30.30.40.50.60.60.81.21.31.82.4
Melting integralA2s
0.0100.0200.0350.050.120.160.240.40.71.4
0.350.490.91.43.26.55.01020264472130230240380
Qty.
1010101010101010101010101010101010101010101010101010
Type
SI 5x20 0.032 ASI 5x20 0.040 ASI 5x20 0.050 ASI 5x20 0.063 ASI 5x20 0.080 ASI 5x20 0.100 ASI 5x20 0.125 ASI 5x20 0.160 ASI 5x20 0.200 ASI 5x20 0.250 ASI 5x20 0.315 ASI 5x20 0.400 ASI 5x20 0.500 ASI 5x20 0.630 ASI 5x20 0.800 ASI 5x20 1.000 ASI 5x20 1.250 ASI 5x20 1.600 ASI 5x20 2.000 ASI 5x20 2.500 ASI 5x20 3.150 ASI 5x20 4.000 ASI 5x20 5.000 ASI 5x20 6.300 ASI 5x20 8.000 ASI 5x20 10.00 A
Cat. no.
2891.02892.02893.02894.02895.02896.02897.02898.02899.02900.02901.02902.02903.02904.02905.02406.02906.02907.02407.02908.02909.02408.02938.02409.02910.02911.0
Rated current,mA/A32 mA40 mA50 mA63 mA80 mA
100 mA125 mA160 mA200 mA250 mA315 mA400 mA500 mA630 mA800 mA
1 A 1.25 A1.6 A2 A
2.5 A3.15 A
4 A5 A
6.3 A8 A
10 A
Rated switch-offcap. A AC
35 ‘L’35 ‘L’35 ‘L’35 ‘L’35 ‘L’35 ‘L’35 ‘L’35 ‘L’35 ‘L’35 ‘L’35 ‘L’35 ‘L’35 ‘L’35 ‘L’35 ‘L’35 ‘L’35 ‘L’35 ‘L’35 ‘L’35 ‘L’35 ‘L’40 ‘L’50 ‘L’63 ‘L’80 ‘L’
100 ‘L’
Voltage drop mV
1000080003500350025002200350310290280230200160140130130120120120120120100100100100100
Power loss, W
0.80.80.40.50.50.60.20.20.20.30.30.30.30.30.40.50.60.70.91.01.21.41.72.02.22.4
Melting integralA2s
0.00010.00020.00040.00070.00170.0022
0.010.020.0370.0730.160.310.160.390.81.52.04.16.21120254279125220
Melting time limits
Micro-fuses/G-fuse cartridges 5 x 20 metric 250 V / slow-acting
Construction: • Transparent glass tube • Nickel-plated brass contact caps• IEC 60127-2/2• EN 60127-2/2• DIN VDE 0820-2/2
Melting time limits
Micro-fuses/G-fuse cartridges 5 x 20 metric 250 V / fast-acting
Construction: • Transparent glass tube • Nickel-plated brass contact caps• IEC 60127-2/2• EN 60127-2/2• DIN VDE 0820-2/2
Type0
SI 5x20 0,032 ASI 5x20 0,040 ASI 5x20 0,050 ASI 5x20 0,063 ASI 5x20 0,080 ASI 5x20 0,100 ASI 5x20 0,125 ASI 5x20 0,160 ASI 5x20 0,200 ASI 5x20 0,250 ASI 5x20 0,315 ASI 5x20 0,400 ASI 5x20 0.500 ASI 5x20 0,630 ASI 5x20 0,800 ASI 5x20 1,000 ASI 5x20 1,250 ASI 5x20 1,600 ASI 5x20 2,000 ASI 5x20 2,500 ASI 5x20 3,150 ASI 5x20 4,000 ASI 5x20 5,000 ASI 5x20 6,300 ASI 5x20 8,000 ASI 5x20 10,00 A
1.5 x Inmin.1 h1 h
2.1 x Inmax.2 min.2 min.
2.75 x Inmin.
200 ms600 ms
max.10 s10 s
4 x Inmin.40 ms150 ms
max.3 s3 s
10 x Inmin.10 ms20 ms
max.300 s300 s
Rated current32 - 100 mA125 mA - 10 A
1.5 x Inmin.1 h1 h1h
2.1 x Inmax.
30 min.30 min.30 min.
2.75 x Inmin.10 ms50 ms50 ms
max.500 ms
2 s2 s
4 x Inmin.3 ms
10 ms10 ms
max.100 ms300 ms400 ms
10 x Inmin.
---
max.300 s300 s300 s
Rated current32 - 100 mA125mA - 10 A8-10 A
SI fuses
Qty.
1010101010101010101010101010101010101010101010101010
325325
Note:• Spade fuses can only be run (the long-term load) with 80% of the fuse’s
rated current. Be sure to take the derating curve into consideration!• The fuse may not be inserted or taken out while under load.• You should use the largest wire section possible so that the thermal pow-
er loss of the fuse can be effectively discharged.• Rated voltage 32 V DC
Motor vehicle fuses
Construction: • Plastic body with 2 contact pins• DIN 72581-3C• Colour-coded amp values
Cat. no.4990.04991.04992.04993.04994.04995.04996.04997.04998.04999.0
Colour codeblueblackgreyvioletpink
bright brownbrown
redCyan
yellow
Rated current0.51.02.03.04.05.07.5101520
Voltage drop mV300130120100100120112858580
Qty.100100100100100100100100100100
TypeSI C 0.500 A/32V SI C 1.000 A/32V SI C 2,000 A/32VSI C 3,000 A/32VSI C 4,000 A/32VSI C 5,000 A/32VSI C 7,500 A/32V
SI C 10,000 A/32VSI C 15,000 A/32VSI C 20,000 A/32V
Cat. no.
4950.04951.04952.04953.04954.04955.04956.04957.04958.04959.04960.04961.04962.04963.04964.04965.04966.04967.04968.04969.04970.0
Rated current.mA/A100 mA125 mA160 mA200 mA250 mA315 mA400 mA500 mA630 mA800 mA
1 A1.25 A1.6 A2 A
2.5 A3.15 A
4 A5 A
6.3 A8 A
10 A
Rated switch-offcap. A AC
1,5 kA
@ 500 V AC
cos ϕ = 1
10 kA @ 400 V AC
cos ϕ = 0.3
Voltage drop, mV
3600340030002500200018001600450400350350300200180160150140135110110100
Power loss W
1.31.41.5
1.601.71.82.00.60.7
0.800.91.01.11.21.31.41.52.22.22.63.0
Melting integralA2s
0.0500.0800.120.200.350.500.800.350.490.91.43.25.2101937
68.080215370620
Type
SI 6,3x32 0,100 A/32 TSI 6,3x32 0,125 A/32 TSI 6,3x32 0,160 A/32 TSI 6,3x32 0,200 A/32 TSI 6,3x32 0,250 A/32 TSI 6,3x32 0,315 A/32 TSI 6,3x32 0,400 A/32 TSI 6,3x32 0.500 A/32 TSI 6,3x32 0,630 A/32 TSI 6,3x32 0,800 A/32 TSI 6,3x32 1,000 A/32 TSI 6,3x32 1,250 A/32 TSI 6,3x32 1,600 A/32 TSI 6,3x32 2,000 A/32 TSI 6,3x32 2,500 A/32 TSI 6,3x32 3,150 A/32 TSI 6,3x32 4,000 A/32 TSI 6,3x32 5,000 A/32 TSI 6,3x32 6,300 A/32 TSI 6,3x32 8,000 A/32 T
SI 6,3x32 10,000 A/32 T
Melting time limits
Micro-fuses/G-fuse cartridges 6.3 x 32 imperial 250 V / 400 V /500 V / slow-acting
Construction: • Ceramic tube • Nickel-plated copper contact caps
Melting time limits
Micro-fuses/G-fuse cartridges 6.3 x 32 imperial 440 V / 500V / fast-acting
Construction: Construction: • Ceramic tube• Nickel-plated brass contact caps
Rated current.mA/A160 mA200 mA250 mA315 mA400 mA500 mA630 mA800 mA
1 A1.25 A1.6 A2 A
2.5 A3.15 A
4 A5 A
6.3 A 8 A
10 A
Rated switch-offcap. A AC
1,5 kA@ 500 V AC
cos ϕ = 1
50 kA@ 500 V AC
cos ϕ = 1
20 kA@ 500 V AC
1,5 kA@ 500 V AC
Voltage drop mV
7000650060001000900800700600400300300280260240220190170160150
Power loss W
2.52.93.4
0.901
1.11.31.41.2
1.301.41.61.82.32.62.93.23.74.0
Melting integralA2s
0.00150.00350.00850.0360.070.190.350.490.40.81.52.559184080150240
Type
SI 6,3x32 0,160 A/32 FSI 6,3x32 0,200 A/32 FSI 6,3x32 0,250 A/32 FSI 6,3x32 0,315 A/32 FSI 6,3x32 0,400 A/32 FSI 6,3x32 0.500 A/32 FSI 6,3x32 0,630 A/32 FSI 6,3x32 0,800 A/32 FSI 6,3x32 1,000 A/32 FSI 6,3x32 1,250 A/32 FSI 6,3x32 1,600 A/32 FSI 6,3x32 2,000 A/32 FSI 6,3x32 2,500 A/32 FSI 6,3x32 3,150 A/32 FSI 6,3x32 4,000 A/32 FSI 6,3x32 5,000 A/32 FSI 6,3x32 6,300 A/32 FSI 6,3x32 8,000 A/32 F
SI 6,3x32 10,000 A/32 F
Cat. no.
4971.04972.04973.04974.04975.04976.04977.04978.04979.04980.04981.04982.04983.04984.04985.04986.04987.04988.04989.0
When using these G-fuse cartridges with 6.3 A or higher, you must ensure that there is sufficient heat dissipation!
1.5 x Inmin.1 h1 h
2.1 x Inmax.
30 min.30 min.
2.75 x Inmin.20 ms
100 ms
max.1.5 s5 s
4 x Inmin.8 ms
20 ms
max.400 ms
1 s
10 x Inmin.
--
max.20 s50 s
Rated current160 - 800 mA1 - 25 A
1.5 x Inmin.1 h1 h
2.1 x Inmax.
30 min.30 min.
2.75 x Inmin.
400 ms400 ms
max.80 s80 s
4 x Inmin.95 ms150 ms
max.5 s5 s
10 x Inmin.10 ms20 ms
max.300 s300 s
Rated current32 - 100 mA125 mA - 10 A
Qty.
101010101010101010101010101010101010101010
Qty.
10101010101010101010101010101010101010
GEN
ERA
L A
CC
ESSO
RIE
S
CONTA-CONNECT
Specific accessories, test-disconnect terminals PTK
Test-disconnect terminals PTK
Test-disconnect terminals are mostly used in the sectors of electricity generation and supply. They are tailored to the variety of switching demands for current-converter secondary circuits that predominate in these sectors.
CONTA-CLIP test-disconnect terminals are available in the fol-lowing three basic versions, each with or without pre-assem-bled STB socket plugs
All versions provide touch-safety protection in compliancewith VBG 4. A captive sliding partition is used to separatethe current and voltage paths. The current switch posi-tion is always easy to detect since the disconnect screwhas a yellow insulating sleeve. Sockets plugs for a test tapcan be attached to all versions using the PS 4 test plug.
TypePTK 10/LTPTK 10/DUAP/L/Q/DSTB 14/4QVS 2VH 19STB 35
Cat. no.1130.21134.22782.22050.02197.02238.02244.0
Quantity1112122
TypePTK 10/QTAP/L/Q/DSTB 14/4QSB 3
Cat. no.1132.22782.22050.02784.0
Quantity3131
TypePTK 10/LTPTK 10/QTPTK 10/DUAL/L/Q/DSTB 14/4STB 30.5QS 2VH 12BS M 3x20QSB 2
Cat. no.1130.21132.21134.22782.22050.02512.02055.02059.02018.02783.0
Quantity36411133633
Required products
Examples of basic circuits using PTK disconnect terminalsCurrent transformers must always have a secondary circuit when electricity meters and measuring instruments are being replaced, or when makingcomparative measurements. Otherwise they could be destroyed by “ramping up”.
1132.2 PTK 10/QTcan be separated perpendicularly
1134.2 PTK/10/DUFeed-through terminal
1131.2 PTK 10/LT/STBcan be separated lengthwisewith STB
1133.2 PTK 10/QT/STB can be separated perpendic-ularly with STB
1135.2 PTK 10/DU/STB Feed-through terminal withSTB
Required products
Required products
Measuring current using a current transformer Operations Swapping the measuring device Testing the measuring device
Measuring current using a current transformer Operations Swapping the measuring device Testing the measuring device
PTK terminal block for three-phase metering: the PTK enables meter testing, comparative measurements, and replacement of individual meters
326
1130.2 PTK 10/LT can be separated lengthwise
Cross-switches The VH 19 connecting sleeves and the BS 25 screws or the STB 35 socket plugs are required for fastening the QVS cross-switch bridge. The screws andsocket plugs are available with or without coloured labelling. When opened, the QVS slider and the screws for the wire connection are not accessible.Thus it is not possible to accidentally unclamp the measuring instrument.
Socket plugs The STB 35 socket plugs are used in the test-disconnect terminals for holding the PS 4 test plug or the KSS 2-8 short-circuit plug. The STB 35 socketplugs can also be used when you need to test at the same time that a QVS is attached. The STB 14/4 socket plugs can be screwed into the cross-connec-tion channel. The are used to hold the PS 4 test plugs or the KSS 2-8 short-circuit plugs.
Qty.
Test plugs / Short-circuit plugsThe PS 4 test plugs are used for the final testing of already-wired test circuits. A cross-connection between two PTK terminals can be establishedwith the KSS 2-8 short-circuit plug.
Cross-switches
TypeTypeCat. no.TypeCat. no.TypeCat. no.TypeCat. no.
QI
QI 2 YE2750.2QI 3 YE2751.2QI 4 YE2752.2QI 10 YE2753.2
QSB
QSB 22783.0QSB 32784.0QSB 42785.0
QVS
QVS 22197.0QVS 32198.0QVS 42199.0
VH 19
VH 192238.0
STB 35
STB 35 YE2244.0STB 35 GN2245.0STB 35 VT2249.0
STB 14/4
STB 14/42050.0
BS25
BS 25 YE2241.0BS 25 GN2242.0BS 25 VT2243.0
BS25
BS 25 without cap2240.0
Socket plugs
TypeTypeCat. no.TypeCat. no.TypeCat. no.TypeCat. no.
PS 4
PS 42051.0
KSS 2-8
KSS 2-82886.0
Test plugs
TypeTypeCat. no.TypeCat. no.TypeCat. no.TypeCat. no.
Qty.
50
50
50
10
Qty.
20
20
20
Qty.
50
50
50
Qty.
50
Qty.
20
Qty.
10
Qty.
50
50
50
Qty.
50
Qty.
20
20
20
Qty.
50
Insulated cross-connector Internal cross-switch bridge Cross-switch bridge Connecting sleeve
Socket plug Socket plug Mounting screw Mounting screw
Test plug Short-circuit plug
327
GEN
ERA
L A
CC
ESSO
RIE
S
Actuating tools BWMA/BW CONTA-CONNECT
Actuating tool BWMA/BW
The spring terminals with 2.5-mm2 cross-section can beoperated using the BW 1 to BW 10 tools and the BWMAmetallic tool.The special BW tools allow you to open multiple terminalpoints simultaneously. The plastic actuating tool featuresimproved safety when working on running facility sec-tions.
TypeType/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.Type/colourCat. no.
Colours availableRatingsBlade size, mmBlade width, mmBlade length, mm
Connection data
AccessoriesType/colourCat. no.For terminal
BWMA 1 (0.5 x 2.5)
BWMA 1 (0.5x2.5)3841.0
0.52.585
FRK 2,5...FDLIS 2,5-4
BWMA 1 (0.5 x 3.5)
BWMA 1 (0.5x3.5)3808.0
0.53.585
ZSRK 2,5...ZSLN 2,5...ZRK 2,5...ZSL 2,5...ZRKD 2,5...ZSLD 2,5...ZIKD 2,5...ZTRK 2,5...ZVMAK 2,5...ZIZA 1,5...ZRK 4...ZSL 4...
BW...(ZRK)
BW 1 (ZRK)3778.0BW 2 (ZRK)3779.0BW 3 (ZRK)3780.0BW 4 (ZRK)3781.0BW 5 (ZRK)3782.0
-3.0
22.5
ZSRK 2,5...ZSLN 2,5...ZRK 2,5...ZSL 2,5...ZRKD 2,5...ZSLD 2,5...ZIKD 2,5...ZTRK 2,5...ZVMAK 2,5...ZIZA 1,5...
Qty.
1
Qty.
1
Qty.
1
1
1
1
1
Qty.
Remarks Remarks Remarks
Page Qty.Page Qty.Page
Metal actuating tool Metal actuating tool Plastic actuating tool
1 poles
2 poles
3 poles
4 poles
5 poles
328
Plastic actuating tool Metal actuating tool Metal actuating tool
BW...(FRK)
BW 1 (FRK)3831.0BW 2 (FRK)3832.0BW 3 (FRK)3833.0BW 4 (FRK)3834.0BW 5 (FRK)3835.0
-2.818
FRK 2,5...FSL 2FTRK 2,5...FRKD 2,5...
Qty.
1
1
1
1
1
Qty.
1
1
1
1
1
Remarks
Qty.Page Qty.Page
BW...(ZRK)
BW 6 (ZRK)3802.0BW 7 (ZRK)3803.0BW 8 (ZRK)3804.0BW 9 (ZRK)3805.0BW 10 (ZRK)3806.0
IEC
-3.0
22.5
ZSRK 2,5...ZSLN 2,5...ZRK 2,5...ZSL 2,5...ZRKD 2,5...ZSLD 2,5...ZIKD 2,5...ZTRK 2,5...ZVMAK 2,5...ZIZA 1,5...
Qty.
1
1
1
1
1
Qty.
Remarks
Page
BW...(FRK)
BW 6 (FRK)3836.0BW 7 (FRK)3837.0BW 8 (FRK)3838.0BW 9 (FRK)3839.0BW 10 (FRK)3840.0
-2.818
FRK 2,5...FSL 2FTRK 2,5...FRKD 2,5...
6 poles
7 poles
8 poles
9 poles
10 poles
1 poles
2 poles
3 poles
4 poles
5 poles
6 poles
7 poles
8 poles
9 poles
10 poles
329
GEN
ERA
L A
CC
ESSO
RIE
S
330
CONTA-CONNECTCE electrical cabinet socket outlet STD-TS|LED
Qty.
5
STD-TS / LED
Screw connection75 x 45 x 6793 g
STD-TS / LED (GN) GR3196.2
250 V AC16 A ACLED green with series resistorgrey RAL 7032MetalPA 6.6 UL 94-V0-20 to +60 °C-20 to +60 °CDirective 2006/95/EGDIN 49440-1DIN VDE 0620-1 : 2010-02
0.2 - 40.2 - 2.5 0.2 - 2.524 - 128M30.5 – 1
MC GS 8/17 R/WH 3321.7
CE electrical cabinet socket outlet STD-TS / LED
The STD-TS / LED electrical cabinet socket outletcan be quickly and conveniently snapped onto astandard TS35 rail using its solid metal foot. This results in significantly reduced assembly work
and installation costs! The electrical connection uses an integral screwterminal and then offers a secure pluggable electrical connection forprogramming devices, service devices or mounting tools. A LED voltagedisplay has also been integrated into the design.
Circuit diagram
· Foot base can be snapped on TS 35 DIN rail· Metal locking clip· Screw connection· Voltage displayed with green LED· Housing made from polyamide 6.6 UL 94-V0
Connection typeSize (L x W x H) with TS 35 x 7.5 mmWeightTypeType ColourCat. no.General specificationsRated voltage UN
Rated current INIndicatorsColourHolding clampInsulation materialAmbient temperature (operating)Ambient temperature (during storage/transport)Standards / Specifications
ApprovalsConnection dataSolid wire cross-section, mm2
Stranded wire cross-section, mm2
Stranded wire with ferrules cross-section, mm2
Wire cross-section, AWGStripping length, mmScrew threadingTorque Nm
AccessoriesMarkersCat. no.
Page
390
Qty.
200
VDE
331
Notes