Upload
others
View
3
Download
0
Embed Size (px)
Citation preview
Frozen Food Architectures
For NRTE Food Safety Success
June 20, 2014
International Microwave Power Institute
Annual Symposium New Orleans LA USA
Steven J. Drucker
Chief Technology Officer
Microwave Science JV LLC
Norcross GA USA
© Microwave Science JV LLC 2014
Can smart selection of ingredients, packaging, package
instructions and consumers’ choice of microwave ovens
assure that consumers’ microwave validation results
match yours?
NRTE Food Safety Success
NRTE Food Safety Success--Sampling
NRTE Food Safety Success--Sampling
Known microwave hostilities
NRTE Food Safety Success—Comfort Food
Leveraging what microwave ovens do best
NRTE Food Safety Success
Microwave ovens love to steam
NRTE Food Safety Success—Packaging High Tech
NRTE Food Safety Success—Packaging Low Tech
Old
New
Subtle packaging adaptations can transform unsafe to safe
What happens when the bell rings?
How much does standing time help?
Who has a thermometer at a) home b) work c) school?
NRTE Food Safety—Standing Time
http://www.powerqualityworld.com/2011/04/ansi-c84-1-voltage-ratings-
Mains voltage varies within bounds set forth
by the American National Standards Institute
(‘ANSI’) in concert with NEMA and EEI
NRTE Food Safety—Operating Environment
10
The standards have worked for 125 years, and so does your Microwave.
Right—so what’s the issue?
11
NRTE Food Safety—Operating Environment
RMS Multi-Meter
Watt Meter
Splitter
GMA Validations Neglect Power Factor.
As per the IEC 60705 microwave oven test protocol
NRTE Food Safety—Operating Environment
AC Power Factor: AC is not DC
What The Power Company Supplies
aka ‘Apparent Power’ or
Voltage * Current
13
NRTE Food Safety—Operating Environment
AC Power Factor: AC is not DC
What you get to
Drink aka ‘Real Power’ or
Voltage * Current * Power Factor
14
NRTE Food Safety—Operating Environment
Watt Meter
Variable AC Transformer
Consider Power Factor.
Measure Voltage and Current Simultaneously
NRTE Food Safety—Operating Environment
Microwave Descriptions
1 GE 1100 Watt 1.2Cuft
2 LG 1200 Watt 1.2Cuft
3 Frigidaire 1100 Watt 1.2Cuft
4 Kenmore 1100 Watt 1.2Cuft
5 Emerson 1100 Watt 1.2Cuft
NRTE Food Safety—Operating Environment
IEC 705 (Mod.) Watts
OVEN ID
Consider Power Factor
Neglect Power Factor (IEC Hookup)
1 895 926
1 878 893
1 879 903
2 924 956
2 926 947
2 941 932
3 894 927
3 886 908
3 887 902
4 941 979
4 940 969
4 935 956
5 863 901
5 855 888
5 849 870
ANOVA
Source of Variation SS df MS F
P-Value F crit
Sample 26739.3 4 6684.824 55.42449 0.000 2.866081
Columns 4451.372 1 4451.372 36.90673 0.000 4.351244
Interaction 243.9584 4 60.98959 0.50567 0.732 2.866081
Within 2412.227 20 120.6114
Total 33846.85 29
Statistical analysis validates
the importance of Power Factor
P=0.000
17
NRTE Food Safety—Operating Environment
127V 120V 113V 106V
MWO 1 930 877 795 671
MWO 2 951 871 755 673
MWO 3 948 897 776 636
MWO 4 937 871 740 644
MWO 5 922 876 720 587
Avg. 937 878 757 642
Avg.
Power
Change
From 120V
7% 0% -14% -27%
IEC 705 (Mod.) 1100 Watt Oven Wattage
ANOVA
Source of Variation SS df MS F P-Value F crit
Rows
4709.439 4 1177.36
3.032686 0.061
3.259167
Columns 258400 3
86133.34
221.8654 0.000
3.490295
Error 4658.68
1 12
388.2234
Total 267768.
1 19 Statistical analysis validates the importance of mains voltage
Power Output at Varying Voltages
P=0.000
Next Let’s Evaluate
Voltage
18
NRTE Food Safety—Operating Environment
Voltage—yes. Power factor--???
NRTE Food Safety—Validation
NRTE Food Safety Success—Comfort Food
NRTE Food Safety—thermometer state of the art
3 seconds $89, 6 seconds $16.
22
NRTE Food Safety—first ever independent validation
23
NRTE Food Safety—Can Smart Ovens Help?
24
NRTE Food Safety—Can Smart Ovens Help?
Can Alice show us the way?
NRTE Food Safety—GPS needed
Smarter packaging, smarter ovens and peer reviewed validation
Are things looking up for consumers?
NRTE Food Safety—Conclusion
Frozen Food Architectures
For NRTE Food Safety Success
June 20, 2014
International Microwave Power Institute
Annual Symposium New Orleans LA USA
Steven J. Drucker
Chief Technology Officer
Microwave Science JV LLC
Norcross GA USA
© Microwave Science JV LLC 2014