4
www.mmidoor.com Florida Building Code Component Approval FL#17347.5

Florida Building Code Component Approval FL#17347€¦ · 3/0 x 6/8 Florida Building Code Component Approval FL#17347.5. Hurricane Impact Frame. ODL’s patented frame design, which

  • Upload
    others

  • View
    104

  • Download
    1

Embed Size (px)

Citation preview

Page 1: Florida Building Code Component Approval FL#17347€¦ · 3/0 x 6/8 Florida Building Code Component Approval FL#17347.5. Hurricane Impact Frame. ODL’s patented frame design, which

www.mmidoor.com

Florida Building Code Component Approval FL#17347.5

Page 2: Florida Building Code Component Approval FL#17347€¦ · 3/0 x 6/8 Florida Building Code Component Approval FL#17347.5. Hurricane Impact Frame. ODL’s patented frame design, which

FS 1102 Panel

3/0 x 6/8

FS 1404 Panel

3/0 x 6/8

FS 1589 Panel

3/0 x 6/8

FS 2002 Panel Planked

2/8 x 6/8 3/0 x 6/8

FS 20True 2 Panel

3/0 x 6/8

FS 216 Panel

2/8 x 6/8 3/0 x 6/8

FS 222 Panel Arch

2/8 x 6/8 3/0 x 6/8

FS 4006 Panel

3/0 x 6/8

FS 59LowE Glass2/8 x 6/83/0 x 6/8

FS 684RLBInternal Mini Blinds with LowE Glass2/8 x 6/83/0 x 6/8

FS 686RLBInternal Mini Blinds with LowE Glass2/8 x 6/8 3/0 x 6/8

FS-686GBG15 Lite -Internal

Muntins with LowE Glass2/8 x 6/8 3/0 x 6/8

FS-686HMSNSatin Nickel

Caming2/8 x 6/83/0 x 6/8

FS-686LI2/8 x 6/83/0 x 6/8

FS-686MENNickel Caming

2/8 x 6/83/0 x 6/8

FS 40True 4 Panel

2/8 x 6/8 3/0 x 6/8

Florida Building Code Component Approval FL#17347.5

Page 3: Florida Building Code Component Approval FL#17347€¦ · 3/0 x 6/8 Florida Building Code Component Approval FL#17347.5. Hurricane Impact Frame. ODL’s patented frame design, which

FG 313 Panel3/0 x 6/8

FG 4006 Panel

3/0 x 6/8

FG 686RLBInternal Mini Blinds with LowE Glass2/8 x 6/8 3/0 x 6/8

FG 686GBGInternal

Muntins with LowE Glass2/8 x 6/8 3/0 x 6/8

FG 686HMSNSatin Nickel

Caming2/8 x 6/8 3/0 x 6/8

FG 686LI2/8 x 6/83/0 x 6/8

FG 686MENNickel Caming

2/8 x 6/8 3/0 x 6/8

FG 1589 Panel

3/0 x 6/8

FG 1404 Panel

3/0 x 6/8

FG 1102 Panel

3/0 x 6/8

FG 216 Panel

2/8 x 6/8 3/0 x 6/8

FG 684RLBInternal Mini Blinds with LowE Glass2/8 x 6/8 3/0 x 6/8

FG 59LowE Glass2/8 x 6/8 3/0 x 6/8

Florida Building Code Component Approval FL#17347.5

Page 4: Florida Building Code Component Approval FL#17347€¦ · 3/0 x 6/8 Florida Building Code Component Approval FL#17347.5. Hurricane Impact Frame. ODL’s patented frame design, which

Hurricane Impact FrameODL’s patented frame design, which is mechanically fastened in the corners to prevent flex, adds strength to the door. With a classic frame profile, the narrow aluminum extrusion adds strength.

Impact-Resistant Laminated GlassOur decorative doorglass, blinds and grilles are sealed between impact-resistant glass on the exterior and tempered safety glass on the interior.

0.090" PVB Inner Layer0.125" Glass Panel

t e c h n o l o g y

HydroShield

Plastpro Fiberglass Doors have been put through a rigorous battery of tests, first in Plastpro’s own testing lab and again by an independent testing facility. The results meet or exceed the Florida Building Standards.

Full length composite stiles, top andbottom rails prevent any water penetration and enhance screw holding ability.

Impact resistant, reinforced skin with deep embossment creates beautiful shadow lines and will not split, warp, dent or rust.

Wide full length LVL for strength and durability provides more stability for multipoint hardware.

No seal or finish is ever required for qualifying warranty.

100% Composite poly-fiber PF Frame is insect resistant, will not rot or split. Twice the screw-holding power.

Please consult your architect, contractor, or building official for the rating needed for your area and home.

Seaward Zone130 mph 3-second gust design wind speed

Inland (I) Zone120 mph 3-second gust design wind speed

Inland (II) Zone110 mph 3-second gust design wind speed

FLORIDA WIND-BORNEDEBRIS REGION

TEXAS FIRST TIER COASTAL COUNTIES

MMI DOOR Severe Weather Entry UnitsOur Severe Weather Entry Unit is approved for use in a range of entrance systems to meet Florida and Texas wind-borne requirements in areas where wind speeds can exceed 140 mph. Our Impact Glass meets DP±47 wind and missile impact code requirements to the WBDR areas (Wind-Borne Debris Region). The laminated glass construction suppresses noise with a sound transmission class (STC Value) of 36.

Florida Non-Impact Region No shutters required.

Designated areas where the basic wind speed is 140mph or greater.

130mph and within 1 mile of the coast.

Removed from Wind-Borne Debris Region

High Velocity Hurricane Zone Broward and Dade County

Florida Building Code Component Approval FL#17347.5

MMI DOOR LOCATIONSMichigan (HQ)

6361 Sterling Drive NorthSterling Heights, MI 48312

586.264.0950800.686.9218

Fax: 586.264.5430

Ohio400 Circle Freeway Drive

Cincinnati, OH 45246513.874.6771800.215.3770

Fax: 513.870.0242

Pennsylvania172 Plummer RoadSidman, PA 15955

814.487.7800800.452.0251

Fax: 814.487.7850