25
Flexible Power Generation for Grid Support utilizing the Aero-derivative Gas Turbine Technology Mike Welch, Siemens Industrial Turbomachinery Ltd., United Kingdom

Flexible Power Generation for Grid Support utilizing the ... · PDF fileSupport utilizing the Aero -derivative Gas Turbine Technology ... • < 20 minutes to full load of combined

  • Upload
    ledang

  • View
    219

  • Download
    1

Embed Size (px)

Citation preview

Flexible Power Generation for Grid Support utilizing the Aero-derivative Gas

Turbine Technology

Mike Welch, Siemens Industrial Turbomachinery Ltd., United Kingdom

14.12.2016

Unrestricted © Siemens 2016

Page 2 MJW / PG DG SPM NM

Contents

• Introduction • Aero-derivative Gas Turbines • Open and Combined Cycle

Applications • ‘Pulse Load’ Operation • Conclusions

14.12.2016

Unrestricted © Siemens 2016

Page 3 MJW / PG DG SPM NM

Security of Supply

Price of Electricity

Environment

The Energy Trilemma

14.12.2016

Unrestricted © Siemens 2016

Page 4 MJW / PG DG SPM NM

• Lowest Cost of Electricity still the key driver

• High penetration of intermittent Renewable Power Generation

• Decentralisation

• New operating regimes for fossil fuels

Changing Market Requirements

14.12.2016

Unrestricted © Siemens 2016

Page 5 MJW / PG DG SPM NM

lexibility ast Response requent Cycling F

Changing demands on Power Plants

14.12.2016

Unrestricted © Siemens 2016

Page 6 MJW / PG DG SPM NM

• Fast start

• High cyclic life

• Multiple daily starts

• No lock-out on shutdown

• Fast ramp rates

• High efficiency

• Modular plant designs

Aero-derivative gas turbines meet today’s market demands

14.12.2016

Unrestricted © Siemens 2016

Page 7 MJW / PG DG SPM NM

Siemens Gas Turbine portfolio Now even stronger with Aero-Derivative products

Heavy-duty gas turbines

Industrial gas turbines

Aeroderivative gas turbines

50H

z 50

Hz

or 6

0Hz

60H

z 400 MW

307 MW

187 MW

296 MW

242 MW

117 MW

53 to 66/54 to 62 MW

27 to 32/28 to 34 MW

4 to 6 MW

48 to 53 MW

37- 40/38-41 MW

33/34 MW

24/25 MW

19/19 MW

13 to 14/13 to 15 MW

8/8 MW to 9 MW

7/8 MW

5/6 MW

Power Generation / Mechanical Drive

SGT5-8000H

SGT5-4000F SGT5-2000E

SGT6-8000H

SGT6-5000F SGT6-2000E

Industrial Trent

SGT-800 SGT-750

SGT-700

Industrial RB211 SGT-600

SGT-500

SGT-400 SGT-300

SGT-200

SGT-100 Industrial 501-K

With Rolls-Royce aero-derivative

technology

14.12.2016

Unrestricted © Siemens 2016

Page 8 MJW / PG DG SPM NM

Aero Trent 800

Derivation of the Industrial Trent

Industrial Trent

14.12.2016

Unrestricted © Siemens 2016

Page 9 MJW / PG DG SPM NM

LP Compressor

(2 Stage)

LP Turbine (5 Stage)

IP Turbine (1 Stage)

HP Compressor

(6 Stage) HP Turbine

(1 Stage)

IP Compressor (8 Stage)

LP Compressor blade number

creates 50/60Hz

25000 hours operation / 5500 Cycles: 3 starts/day for 4 ½ years

Industrial Trent Gas Turbine: 3 independent shafts for flexibility

14.12.2016

Unrestricted © Siemens 2016

Page 10 MJW / PG DG SPM NM

2.8m (9.1ft)

• Compact footprint: < 30m x 15m (100’ x 50’) • Installation possible < 75 days • Engine change-out within 48 hours • Engine less than 15 tonnes: air freight • Low maintenance costs

• < $5/MWh total (continuous operation)

Designed for Maintainability and Quick Installation

14.12.2016

Unrestricted © Siemens 2016

Page 11 MJW / PG DG SPM NM

• High Energy Efficiency

• Competitive Installed

Costs • US$700 – US$900/kW

• Power enhancement

through ISI • +10MW at ISO

• Synchronous condenser

possibilities

0 20 40 60 80 100

Open Cycle

Combined Cycle

Cogeneration

Typical overall Energy Efficiency for Industrial Trent options (%)

Decentralised Power Generation

Security of Supply

Price of Electricity

Environment

14.12.2016

Unrestricted © Siemens 2016

Page 12 MJW / PG DG SPM NM

0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0 9.5 10.0 Time (Minutes)

Power Generated (MW)

50

OEM 2 Dual Fuel Engine Ultra-Fast Start *

SGT-300

501-KB7

OEM 3 Dual Fuel Engine Fast Start

13MW Class Industrial GT Fast Start

* Ultra fast start requires specific pre-start conditions to be met

Industrial Trent (21MW/min ramp)

OEM 4 Gas Engine Fast Start

OEM 1 Gas Engine Regular Start

25

35

15

5

45

Industrial Trent (35MW/min ramp)

Fast Start-up of Gas Turbines

Industrial Trent 100% Load - more than 50MW - from cold in less than 10 minutes

14.12.2016

Unrestricted © Siemens 2016

Page 13 MJW / PG DG SPM NM

Part-Load Efficiency and Ramp Rate

Multiple Units allow: • Operational Flexibility • High efficiency across wide operating range • Low power plant turndown

• approx. 5% rated output while maintaining emissions compliance

• Rapid response to grid demand • 20% power increase per unit in <20 seconds

• Low station power loss during GT maintenance outage

1. Open cycle, natural gas fuel, ISI

14.12.2016

Unrestricted © Siemens 2016

Page 14 MJW / PG DG SPM NM

Industrial Trent: High stress operating cycle – no maintenance penalty

Operation over 2 day period – US location

14.12.2016

Unrestricted © Siemens 2016

Page 15 MJW / PG DG SPM NM

Combined Cycle

High efficiency, fast response Combined Cycle possibilities

Industrial Trent: > 53% net efficiency, full load <40 minutes

• Low exhaust temperature low pressure, low temperature HRSG • reduced thermal stress allows improved cycling performance • Fast / multiple start capability with OTSG

• Duct firing for further flexibility • 2 + 1 with duct firing: 20% to 110% rated station load

• ‘Water-free’ possibilities: Organic Rankine Cycle • < 20 minutes to full load of combined cycle plant possible on warm start

14.12.2016

Unrestricted © Siemens 2016

Page 16 MJW / PG DG SPM NM

4 hour pulse

14 hour pulse

0 120 240

100

50

75

25

Time from beginning of Pulse (mins)

Pulse Load Operation

14.12.2016

Unrestricted © Siemens 2016

Page 17 MJW / PG DG SPM NM

100MW Power Plant

ICE CC ICE Trent DLE OC

Trent DLE CCGT

Trent + ORC

Full Load Net Efficiency % 44 49.2 41.87 53 50

Start-up time Mins 5 50 10 40 20

Shut-down time Mins 1 20 5 20 10

O&M costs (2000 hrs/yr operation)

$/MWh 5.5 5.5 4 5 4.5

Start-up costs $/MW - - - -

Pulse Load Operation

14.12.2016

Unrestricted © Siemens 2016

Page 18 MJW / PG DG SPM NM

0

5000

10000

15000

20000

25000

30000

35000

40000

45000

4 8 14

ICE

ICE CC

Trent DLE

Trent DLE CCGT

Trent DLE + ORC

Aero-derivative Gas Turbines offer a competitive solution….

Cost per pulse (US$)

14.12.2016

Unrestricted © Siemens 2016

Page 19 MJW / PG DG SPM NM

And a clean one too….

0

100

200

300

400

500

600

NOx CO UHC Particulates Formaldehyde

18MW RICE

Industrial Trent 60 DLE

ISO, zero loss Natural Gas fuel 250MW Plant Output 700 Hours/year operation Open cycle No post-combustion clean-up

Environmental Benefits of Gas Turbines • > 70% NOx reduction • > 85% CO reduction • > 98% UHC reduction • > 35% Particulates

reduction • > 90% VOC reduction

Combustion Emissions Comparison (tonnes/year)

14.12.2016

Unrestricted © Siemens 2016

Page 20 MJW / PG DG SPM NM

… with low GHG Emissions

8090

100110120130140150160170180

35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50

CO2 Emissions - gas fuel

CO2eq Emissions (3.2g/kWhmethane slip)CO2eq Emissions (0.05g/kWhmethane slip)CO2 Emissions - diesel fuel

3.2 g/kWh methane slip almost eliminates CO2 savings by switching to gas from diesel - 48% efficient power plant emits CO2 eq to 36% efficient power plant with no methane slip - 0.05 g/kWh methane slip has negligible impact on CO2 eq

CO2 EQ Emissions (Tonnes/hour) for 250MW Power Plant according to efficiency

Tonnes/hour GHGs

Power Plant Efficiency (%)

14.12.2016

Unrestricted © Siemens 2016

Page 21 MJW / PG DG SPM NM

Industrial Trent Ultra-Flexible combined cycle

Warm start, DLE operation Start-up after up to 8 hours standstill • Gas Turbine at full load in 7

minutes • Steam Turbine in 22 minutes.

0

10

20

30

40

50

60

70

0 10 20

Elec

tric

pow

er (M

W g

ross

)

Time (minutes)

Industrial Trent Flex CC< 8 hours standstill

Plant

GT

ST

14.12.2016

Unrestricted © Siemens 2016

Page 22 MJW / PG DG SPM NM

Hybrid Power Plant

Combine GT / CCGT with BESS for even faster response

-10

0

10

20

30

40

50

60

70

80

90

0 10 20 30 40

Elec

tric

pow

er (M

W g

ross

)

Time (minutes)

Plant

GT

ST BESS

• BESS moves Plant response to within 1 second 80 MW, 30 MWh BESS capacity - 15 MWh used

14.12.2016

Unrestricted © Siemens 2016

Page 23 MJW / PG DG SPM NM

Aero-derivative Gas Turbines offer fast, flexible and efficient despatchable power generation to address the Energy Trilemma

Conclusions

• Low environmental impact • GHGs, Combustion Emissions, Water

• Enhances security of electricity supplies • Voltage and Frequency support

• Competitive economics for low cost electricity needs in a high intermittent renewables scenario

14.12.2016

Unrestricted © Siemens 2016

Page 24 MJW / PG DG SPM NM

Disclaimer

This document contains forward-looking statements and information – that is, statements related to future, not past, events. These statements may be identified either orally or in writing by words as “expects”, “anticipates”, “intends”, “plans”, “believes”, “seeks”, “estimates”, “will” or words of similar meaning. Such statements are based on our current expectations and certain assumptions, and are, therefore, subject to certain risks and uncertainties. A variety of factors, many of which are beyond Siemens’ control, affect its operations, performance, business strategy and results and could cause the actual results, performance or achievements of Siemens worldwide to be materially different from any future results, performance or achievements that may be expressed or implied by such forward-looking statements. For us, particular uncertainties arise, among others, from changes in general economic and business conditions, changes in currency exchange rates and interest rates, introduction of competing products or technologies by other companies, lack of acceptance of new products or services by customers targeted by Siemens worldwide, changes in business strategy and various other factors. More detailed information about certain of these factors is contained in Siemens’ filings with the SEC, which are available on the Siemens website, www.siemens.com and on the SEC’s website, www.sec.gov. Should one or more of these risks or uncertainties materialize, or should underlying assumptions prove incorrect, actual results may vary materially from those described in the relevant forward-looking statement as anticipated, believed, estimated, expected, intended, planned or projected. Siemens does not intend or assume any obligation to update or revise these forward-looking statements in light of developments which differ from those anticipated.

Trademarks mentioned in this document are the property of Siemens AG, its affiliates or their respective owners. TRENT® and RB211® are registered trade marks of and used under license from Rolls-Royce plc. Trent, RB211, 501 and Avon are trade marks of and used under license of Rolls-Royce plc.

Thank you. Any questions ?

Mike Welch Industry Marketing Manager

Siemens Industrial Turbomachinery Ltd. Waterside South

Lincoln, United Kingdom Phone: +44 (1522) 584000 Mobile: +44 (7921) 242234

E-mail: [email protected]

Please visit us at Booth 5100