Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
File No. EA2020-116
CITY OF RICHLAND Determination of Non-Significance
Description of Proposal: Construction of an approximately 46,500 s.f. addition to an
existing corn processing transfer terminal.
Proponent: Central Washington Corn Processing Attn: Chad Walters 5207 E. 3rd Ave. Spokane Valley, WA 99212
Location of Proposal: The project site is located at 2900 Logston Blvd., Richland, WA
99352.
Lead Agency: City of Richland
The lead agency for this proposal has determined that it does not have a probable significant adverse impact on the environment. An environmental impact statement (EIS) is not required under RCW 43.21C.030(2)(c). This decision was made after review of a completed environmental checklist and other information on file with the lead agency. This information is available to the public on request. ( ) There is no comment for the DNS. ( X ) This DNS is issued under WAC 197-11-340(2); the lead agency will not act on this proposal for fourteen days from the date of issuance. ( ) This DNS is issued after using the optional DNS process in WAC 197-11-355. There is no further comment period on the DNS.
Responsible Official: Mike Stevens Position/Title: Planning Manager Address: 625 Swift Blvd., MS #35, Richland, WA 99352 Date: July 16, 2020 Signature______________________________
Will match the existing building structure height. Existing structure is 60' high at peak, same as existing.Building is Pre-Engineered metal building with metal cladding same as existing.
SHEET NAME
DESIGNWEST
A R
C H
I T
E C
T S
,
P .
A .
A
B
C
D
E
F
10987654321
10987654321
A
B
C
D
E
F
SHEET
© C
OP
YR
IGH
T D
ES
IGN
WE
ST
AR
CH
ITE
CTS
P.A
. DE
SIG
N C
ON
CE
PTS
AN
D D
RA
WIN
GS
NO
T TO
BE
RE
US
ED
WIT
HO
UT
WR
ITTE
N P
ER
MIS
SIO
N O
F A
RC
HIT
EC
T
●
ME
RID
IAN
, ID
AH
O
● P
UL
LM
AN
, W
AS
HIN
GT
ON
●
●
KE
NN
EW
ICK
, W
AS
HIN
GT
ON
●
O
NT
AR
IO,
OR
EG
ON
●
ww
w.d
esig
nw
estp
a.c
om
DATE
06.02.20
CW
CP
FLAT
HO
USE
STO
RAG
E
RIC
HLA
ND
, WA
9935
433
34 L
OG
STO
N B
LVD
.
CHECKED BY
DRAWN BY
EB
AP
REVISIONS
JOB NUMBER20046
Aus
tin P
arke
r 6/
2/20
20 2
:16:
48 P
M
CENTRAL WASHINGTON
CORN PROCESSORS
FLATHOUSE STORAGE
3334 LOGSTON BLVD., RICHLAND, WA 99354
ARCHITECTURALCONTACT:
ELIOT BLACK
DESIGN WEST ARCHITECTS, P.A.
830 N. COLUMBIA CENTER BLVD., SUITE E
KENNEWICK, WASHINGTON 99336
TEL: (509) 783-2244
OWNERINDUSTRIAL SYSTEMS AND FABRICATION
16208 E. LACROSSE LANE
SPOKANE VALLEY, WASHINGTON 99216
TEL: (509) 534-1743
CONTACT:
DAVID WOLF
PROJECT SITE
DRAWING INDEXGENERAL:
TITLE SHEET
CODE EVAL. - SITE PLAN - CODE PLAN
ELEVATIONS
G1.00
G1.01
G1.02
GENERAL STRUCTURAL NOTES
TYPICAL DETAILS
FOUNDATION PLAN
FOUNDATION PLAN
GRAIN BIN DETAILS
GENERAL NOTES1. CONTRACTOR TO VERIFY WITH UTILITIES EXACT LOCATION OF EXISTING UNDERGROUND SERVICES. CONTACT CALL BEFORE YOU DIG AT: (800) 424-5555
2. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF THESE DRAWINGS, THE SPECIFICATIONS, AND THE CURRENT EDITIONS OF THE IBC, IMC, NEC AND THE WASHINGTON STATE ENERGY CODE, AND ALL BENTON COUNTY
REGULATIONS. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL REQUIRED PERMITS AND PROVIDING ALL REQUIRED DOCUMENTATION FOR ISSUANCE OF PERMITS, INCLUDING ANY AND ALL ENGINEERING,
STAMPED AND SIGNED BY REGISTERED PROFESSIONAL ENGINEERS IN THE STATE OF WASHINGTON APPROPRIATE TO THE DISCIPLINE.
3. THE CONTRACTOR AGREES TO ASSUME SAFE AND COMPLETE RESPONSIBILITY FOR THE JOB SITE DURING THE COURSE OF THE PROJECT, INCLUDING THE SAFETY OF ALL PERSONS AND PROPERTY, THAT THIS REQUIREMENT
SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE ARCHITECT AND OWNER HARMLESS FROM ANY AND ALL LIABILITY,
REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR ARCHITECT, OR THIRD PARTY IN VIOLATION
OF THE LAW OR IN TRESPASS. THE CONTRACTOR SHALL PRACTICE SAFETY AT ALL TIMES AND SHALL FURNISH, ERECT, AND MAINTAIN SUCH FENCES, BARRICADES, LIGHTS, AND SIGNS NECESSARY TO GIVE ADEQUATE
PROTECTION TO THE PUBLIC AT ALL TIMES. THE ARCHITECT MAKES NO WARRANTY THAT THE CONSTRUCTION-PHASE FENCES, ETC., ARE ADEQUATE TO ENSURE SAFETY DURING CONSTRUCTION OPERATIONS.
4. DURING CONSTRUCTION THE SAFETY OF THE WORKERS, VISITORS, AND THE PROTECTION OF PROPERTY IS SOLELY THE RESPONSIBILITY OF THE CONTRACTOR. THE ARCHITECT SHALL NOT INCLUDE OBSERVATION OF
SAFETY MEASURES IN SITE VISIT OBSERVATION REPORTS.
PROJECT TEAM
VICINITY MAP
RICHLAND, WADOOR NUMBER
01
EXTERIOR ELEVATION
INTERIOR ELEVATION
A1/4.00
A1/7.10
SEE SHEET A6.00
SEE SHEET A8.00 & A9.01
BUILDING SECTION
A1
A5.20
FLOOR & WALL ASSEMBLIES
ROOF ASSEMBLIES
REVISIONS
WINDOW TYPES
ELEVATION MARK
DETAIL
WALL SECTION
E
01
A1
A5.20
100'-0"
T.O.FLOOR
SYMBOLS
CRUSHED GRAVEL
FINISH WOOD
PLYWOOD
SAND
CONT. WOOD
RIGID INSUL.
BATT INSUL.
WOOD BLKNG
EARTH
STEEL CONT.
CONCRETE
CMU
MATERIAL KEY
ABBREVIATIONS
SEE SHEET A8.00
A1
A5.20
NORTH
A1
A1
ACOUST.
WITH
WITH OUTW/O
W/
WIDE FLANGE
WATER CLOSET
WIDE
UNLESS NOTED OTHERWISE
TYPICAL
TOP AND BOTTOM
TOP OF
THICK
TELEVISION
TELEPHONE
STANDARD
SQUARE
SIMILAR
SEALED CONCRETE
ROUGH OPENING
REVISION
REFERENCE
RADIUS
PLATE
PENNY
W.F.
W.C.
W
U.N.O.
TYP.
T&B
T.O.
T
T.V.
TEL.
STD.
SQ.
SIM.
S.C.
R.O.
REV.
REF.
R
PL
d
OUTSIDE DIAMETER
OPPOSITE
OPENING
ON CENTER
NOT TO SCALE
MINIMUM
MAXIMUM
MASONRY
MASONRY BEAM
MASONRY OPENING
O.D.
OPP.
OPNG.
O.C.
NTS
MIN
MAX
MAS.
MB
M.O.
T.G.
T.S.
TOP OF GRADE
TOP OF SIDEWALK
UNIFORM BUILDING CODEUBC
SURFS. SURFACES
REINF. REINFORCED
SERV. SERVICE
PERF. PERFORATED
MET. METAL
.
.
SYST. SYSTEM
M.H. MAN HOLE
NO. NUMBER
POS. POSITIVE
P.T. PRESSURE TREATED
WD. WOOD
RET. RETAINING
THICK THICKENED
STRUCT. STRUCTURAL
WAREHSE. WAREHOUSE
MEMB. MEMBRANE
MANUF. MANUFACTURER
SHT. SHEET
THRESH. THRESHOLD
VAN. VANITY
PREFAB. PREFABRICATED
PLYWD. PLYWOOD
REQD. REQUIRED
PREMANUF. PREMANUFACTURED
SUSP. SUSPENDED
SOFTWD. SOFTWOOD
PLAST.
RESIST RESIST
S.C.W. SOLID CORE
VERT. VERTICAL
SYNTH. SYNTHETIC
TEXT. TEXTURE
NONPERF. NONPERFORATED
LB. POUND
SHEATHG. SHEATHING
TEMP. TEMPORARY
TEMPRD. TEMPERED
O.H. OVERHEAD
PERIM. PERIMETER
T&G TONGUE & GROOVE
TRANS.
WAINS. WAINSCOT
STOR. STORAGE
RETRACT. RETRACTABLE
S.S. STAINLESS STEEL
SALV. SALVAGE
SHEET VINYLSV.
VCT. VINYL COMPOSITION TILE
PTPAINT
R.B. RUBBER BASE
SCHED. SCHEDULE
T.W.C. TACKABLE WALL COVERING
V.B. VENTED BASE
V.W.C. VINYL WALL COVERING
P.O.C. POINT OF CONNECTION
M. MIRROR
PTD. PAPER TOWEL DISPENSER
S.D. SOAP DISPENSER
R.D. ROOF DRAIN
O.S. OVERFLOW SCUPPER
T.O.D. TOP OF ROOF DECK
PLASTIC
TRANSITION
OWNER FURNISHEDOFCI
CONTRACTOR INSTALLED
OWNER FURNISHEDOFOI
OWNER INSTALLED
INSIDE DIAMETER
HORIZONTAL
HEIGHT
HIGH
GRADE
FOUNDATION
FOOTING
FLOOR
FINISHED FLOOR
FINISH
I.D.
HORIZ.
HT.
GR.
FDN.
FTG.
FLR.
F.F.
FIN.
EQUAL OR EQUIVALENT
ELEVATION
ELECTRIC WATER COOLER
ELECTRICAL
EACH
DIAMETER
DRINKING FOUNTIAN
CONTINUOUS
CONCRETE MASONRY UNITCMU
COLUMN
CLOSED CIRCUIT TELEVISION
CLEAN OUT
CHANNEL
CENTER LINE
CEILING
BOTTOM OF
BUILDING
BENCH MARK
BEARING
ANGLE
ALTERNATE
ABOVE FINISHED FLOOR
EQ.
ELEV.
E.W.C.
ELEC.
EA.
DIA.
D.F.
CONT.
COL.
C.C.T.V.
C.O.
C
CL
CLG.
B.O
BLDG.
B.M.
BRG
L
ALT.
AFF
EXIST EXISTING
DIV. DIVISION
ENGRD. ENGINEERED
ASPH. ASPHALT
CONT. JT. CONTROL JOINT
JT. JOINT
CONC. CONCRETE
C.I. CAST IRON
IRRIG. IRRIGATION
CORRUG. CORRUGATED
DIST. DISTRIBUTION
GALV. GALVANIZED
DEG. DEGREE
DENS. DENSITY
DBL. DOUBLE
C.F. CUBIC FEET
LAT.
DIR. DIRECT
BOT. BOTTOM
FD. FLOOR DRAIN
CONSTR. CONSTRUCTION
EXP. EXPANSION
HDWD. HARDWOOD
BLK. BLOCK
BM. BEAM
ACOUSTICAL
GA.GAUGE
ALUM. ALUMINUM
.
BD. BOARD
EXT. EXTERIOR
FLDG. FOLDING
FURRG. FURRING
ASSEM. ASSEMBLY
BLKG. BLOCKING
LAM. LAMINATED
FRAMG. FRAMING
HDBD. HARDBOARD
CHEM. CHEMICAL
LAMIN. LAMINATE
H.C.W. HOLLOW CORE
L. LONG
CLR. CLEAR
INFILTR. INFILTRATION
INSUL. INSULATION
ELASTO.
B.U.
GYP. GYPSUM
H.M. HOLLOW METAL
HR. HOUR
HORIZ. HORIZONTAL
LT. LIGHT
CERAM. CERAMIC
COMP. COMPOSITION
FLRG. FLOORING
F.E. SURFACE MT FIRE EXTINGUISHER
CAB. CABINET
DISP. DISPENSER
CUST. CUSTODIAL
FWD. FORWARD
ADJA. ADJUSTABLE
ADJ. ADJACENT
CERAMIC TILE
CARPET
CT.
CPT
HW. HARDWOOD
F.T. FIRE TREATED
EPXY. EPOXY PAINT
F.V. FIELD VERIFY
H.
HD. HAND DRYER
GB. GRAB BAR
F.E.C. FIRE EXTINGUISHER & CABINET
L.M.B. LIQUID MARKER BOARD
IBC INTERNATIONAL BUILDING CODE
CJ CONTROL JOINT
BUILT-UP
ELASTOMERIC
LATERAL
1
-
2
4
0
KIN
GS
GA
TE
W
AY
BATTELLE BLVD
G1.00
TITLE SHEET
STRUCTURALCONTACT:TD & H ENGINEERING
303 EAST 2ND AVE
SPOKANE, WASHINGTON 99202
TEL: (509) 622-2888
CIVILCONTACT:
DARRAL MOORE
JUB ENGINEERS
2810 W. CLEARWATER AVE., SUITE 201
KENNEWICK, WA 99336
TEL: (509) 783-2144
STRUCTURAL:
S1.0
S1.1
S4.0
S4.1
S5.0
GENERAL INFORMATION
ANCHOR BOLT PLAN
ANCHOR BOLT PLAN
BUILDING ACCESSORIES
RIGID FRAME ELEVATION
RIGID FRAME ELEVATION
RIGID FRAME ELEVATION
RIGID FRAME ELEVATION
RIGID FRAME ELEVATION
ROOF FRAMING
ROOF FRAMING
ENDWALL FRAMING
ENDWALL FRAMING
SIDEWALL FRAMING
SIDEWALL FRAMING
SIDEWALL FRAMING
ERECTION DETAILS
ERECTION DETAILS
ERECTION DETAILS
METAL BUILDING WEST ADDITION:
SHEET 1
SHEET 2
SHEET 3
SHEET 4
SHEET 5
SHEET 6
SHEET 7
SHEET 8
SHEET 9
SHEET 10
SHEET 11
SHEET 12
SHEET 13
SHEET 14
SHEET 15
SHEET 16
SHEET 17
SHEET 18
SHEET 19
GENERAL INFORMATION
ANCHOR BOLT PLAN
ANCHOR BOLT PLAN
BUILDING ACCESSORIES
RIGID FRAME ELEVATION
RIGID FRAME ELEVATION
RIGID FRAME ELEVATION
RIGID FRAME ELEVATION
RIGID FRAME ELEVATION
ROOF FRAMING
ROOF FRAMING
ENDWALL FRAMING
ENDWALL FRAMING
SIDEWALL FRAMING
SIDEWALL FRAMING
SIDEWALL FRAMING
ERECTION DETAILS
ERECTION DETAILS
ERECTION DETAILS
METAL BUILDING EAST ADDITION:
SHEET 1
SHEET 2
SHEET 3
SHEET 4
SHEET 5
SHEET 6
SHEET 7
SHEET 8
SHEET 9
SHEET 10
SHEET 11
SHEET 12
SHEET 13
SHEET 14
SHEET 15
SHEET 16
SHEET 17
SHEET 18
SHEET 19
ST
EV
EN
S D
RIV
E
GE
OR
GE
W
AS
H. W
AY
CO
LU
MB
IA
R
IV
ER
CIVIL:
OVERALL SITE LAYOUTC-2
METAL BUILDINGCONTACT:BEHLEN BUILDING SYSTEMS
4025 EAST 23RD STREET
COLUMBUS, NEBRASKA 68602
TEL: (402) 564-3111
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/L
P
/
L
P
/L
P
/
L
P
/L
P
/L
P
/L
P
/L
P
/L
P
/L
P
/L
P
/L
P
/L
P
/L
P
/L
P
/L
P
/L
P
/L
P
/L
P
/L
P
/L
P
/L
P/L
P/L
P
/L
P/L
P
/L
P/L
P/L
P/L
P/L
P/L
P/L
P/L
P/LP/LP/LP/LP/LP/LP/LP/LP/LP/LP/LP/LP/LP/LP/LP/LP/LP/LP/LP/LP/LP/LP/LP/LP/LP/LP/LP/LP/LP/LP/LP/LP/L
P/L
P/L
P/L
P/L
P/L
P/L
P/L
P/L
P/L
P/L
P/L
P/L
P
/L
P
/L
P
/L
P
/L
P
/L
P
/L
P
/L
P
/L
P
/L
P
/L
P
/L
P
/L
P
/L
P
/L
P
/L
P
/L
P
/L
P
/L
P
/L
P
/L
P
/L
P
/L
P
/L
P
/L
P
/
L
P
/L
P
/L
P
/L
P
/
L
P
/
L
P
/L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/L
P
/
L
P
/
L
P
/L
P
/
L
P
/L
P
/
L
P
/
L
P
/L
P
/
L
P
/L
P
/L
P
/L
P
/L
P
/
L
P
/L
P
/L
P
/L
P
/L
P
/L
P
/L
P
/
L
P
/L
P
/L
P
/L
P
/L
P
/L
P
/L
P
/L
P
/L
P
/L
P
/L
P
/L
P
/L
P/L
P
/L
P/L
P/L
P
/L
P
/L
P/L
P/L
P/L
P/L
P/L
P/L
P/L
P/L
P/L
P/L
P/L
P/L
P/L
P/L
P/L
P/L
P/L
P/L
P/L
P/L
P/L
P/L
P/L
P/L
P/L P/L P/L
P/L P/L
P/L
P/L P/L
P/L
P/L P/L
P/L
P/L P/L
P/L
P/L P/L
P/L P/L P/L
P/L P/L
P/L
P/L P/L
P/L
P/L P/L
P/L
P/L P/L
P/L
P/L P/L
P/L P/L P/L
P/L P/L
P/L
P/L P/L
P/L
P/L P/L
P/L
P/L P/L
P/L
P/L P/L
P/L P/L P/L
P/L P/L
P/L
P/L P/L
P/L
P/L P/L
P/L
P/L P/L
P/L
P/L P/L
P/L P/L P/L
P/L P/L
P/L
P/L P/L
P/L
P/L P/L
P/L
P/L P/L
P/L P/L P/L
P/L P/L P/L
P/L P/L
P/L
P/L P/L
P/L
P/L P/L
P/L
P/L P/L
P/L P/L P/L
P/L P/L P/L
P/L P/L
P/L
P/L P/L
P/L
P/L P/L
P/L
P/L P/L
P/L P/L P/L
P/L P/L
P/L
P/L P/L
P/L
P/L P/L
P/L
P/L P/L
P/L
P/L P/L
P/L
P/L
P/L
P/L
P/L
P/L
P/L
P/L
P/L
P/L
P/L
P/L
P/L
P/L
P/L
P/L
P/L
P/L
P/L
P/L
P/L
P/L
P/L
P/L
P/L
P/L
P/L
P/L
P/L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
P
/
L
E
G
E
G
E
G
E
G
E
G
E
G
E
G
E
G
E
G
E
G
E
G
E
G
E
G
E
G
E
G
E
G
E
G
E
G
E
G
E
G
E
G
EG
EG
E
G
E
G
E
G
E
G
E
G
E
G
E
G
EG
E
G
EG
E
G
E
G
E
G
E
G
E
G
EG
E
G
E
G
G1.01
CODE EVAL.SITE PLANCODE PLAN
NORTH
SCALE: 1/32" = 1'-0"
A3 ADDITION FLOOR PLANS
CODE EVALUATION
SHEET NAME
DESIGNWEST
A R
C H
I T
E C
T S
,
P .
A .
A
B
C
D
E
F
10987654321
10987654321
A
B
C
D
E
F
SHEET
© C
OP
YR
IGH
T D
ES
IGN
WE
ST
AR
CH
ITE
CTS
P.A
. DE
SIG
N C
ON
CE
PTS
AN
D D
RA
WIN
GS
NO
T TO
BE
RE
US
ED
WIT
HO
UT
WR
ITTE
N P
ER
MIS
SIO
N O
F A
RC
HIT
EC
T
●
ME
RID
IAN
, ID
AH
O
● P
UL
LM
AN
, W
AS
HIN
GT
ON
●
●
KE
NN
EW
ICK
, W
AS
HIN
GT
ON
●
O
NT
AR
IO,
OR
EG
ON
●
ww
w.d
esig
nw
estp
a.c
om
DATE
06.02.20
CW
CP
FLAT
HO
USE
STO
RAG
E
RIC
HLA
ND
, WA
9935
433
34 L
OG
STO
N B
LVD
.
CHECKED BY
DRAWN BY
EB
AP
REVISIONS
JOB NUMBER20046
Aus
tin P
arke
r 6/
2/20
20 2
:57:
56 P
M
NORTH
SCALE: NTS
C3 SITE PLAN
915'-9"
150'-0" 615'-9" 150'-0"
155'-0"
MANUAL OVERHEAD
ROLL UP DOOR
3-0x7-0 EGRESS DOOR -
FIELD LOCATE MAXIMUM
30' FROM END OF
BUILDING - PROVIDE
ILLUMINATED EXIT SIGN
EXISTING 3-0x7-0
EGRESS DOOR
EXISTING 3-0x7-0
EGRESS DOOR
EXISTING SILOS AND
CONVEYOR SYSTEM
EXISTING TRAIN TRACKS
PROPERTY LINE
60' YARD - TO BE
MAINTAINED AROUND
BUILDING
MANUAL OVERHEAD ROLL UP
DOOR
3-0x7-0 EGRESS DOOR -
FIELD LOCATE MAXIMUM 30'
FROM END OF BUILDING -
PROVIDE ILLUMINATED EXIT
SIGN
EXISTING 3-0x7-0
EGRESS DOOR
+/-30'-0" +/-30'-0"
EXISTING BUILDING EXISTING BUILDING
EXISTING BUILDING EAST ADDITION
WEST ADDITION
EXISTING SCALE HOUSE
AND SCALES
155'-0"
150'-0" 150'-0"615'-9"
MOVEABLE PARTIAL
HEIGHT CONCRETE
BARRIER
TRUCK LANE TRUCK LANE
EAST ADDITION
WEST ADDITION
60'-0"
MOVABLE BARRIERS SHALL BE
CONFIGURED TO ENSURE TOTAL TRAVEL
DISTANCE FROM ANY LOCATION DOES
NOT EXCEED 300', TYP
Project Address:
CENTRAL WASHINGTON CORN PROCESSORS
3334 LOGSTON BLVD.
RICHLAND, WA 99354
Authorities having Jurisdiction:
City of Richland Jim Oliver, Building Official
Building Department Tel: 509-942-7762
625 Swift Blvd.
Richland, WA 99352
Planning & Zoning Requirements:
Current Zoning:
The project area is zoned “I-M”
Parking:
No changes due to building be unoccupied.
Height, Setback Limitations:
Maximum Height = 55' required, 45' to average sloped roof height
Yard Setback = 60' minimum (per negotiated exception)
Building Code:
Applicable Requirements:
International Building Code, 2015 edition; with WAC amendments
International Energy Conservation Code, 2015 edition; with WAC Amendments
Construction type: II - B
Occupancy class: U, Agricultural
Fire Protection: Not required (per negotiated exception)
Fire Alarm: Very Early Smoke Detection and Alarm (per negotiated exception)
WSEC: Building is exempt from Washington State Energy requirements per C402.1.1
as a low energy building
Allowable Areas & Heights:
Allowable Areas / Heights: Type II-B Construction, “U” Occupancy
One-story unlimited area buildings permitted per IBC C102.2 where 60' yards are provided.
Increased Areas / Heights: (Section 506):
N/A
Fire Resistive Requirements for Construction Components:
Type II - B (Tables 601, 602, and 706.4)
Component: Rating
Fire Walls 2 hour (see footnote a to Table 706.4)
Exterior bearing Walls: no rating, non-combustible (see Table 601)
Exterior Non-Bearing Walls: 1 hour<10 feet, non-combustible (see Table 602)
no rating elsewhere, non-combustible (see Table 602)
Exterior Openings: no limits > 20 feet (reference Table 705.8)
Interior Bearing Walls: no rating
Interior Non-Bearing Walls: no rating
Structural Frame: no rating
Permanent Partitions: no rating
Shaft Enclosures: no rating
Floor & Floor/Ceilings: no rating
Roofs & Roof/Ceilings: no rating
Roofing Classification: Class “C” (Table 1505.1)
Estimated Occupant Loads & Exiting:
Building is considered unoccupied
Sanitation Systems & Plumbing Fixtures:
IBC Chapter 29, WAC Amended Table 2902.1 (using 2012 WAC amendments)
N/A
Commentary:
The code interpretation is based on the previously agreed to building conditionspresented in Womer & Associates letter dated April 7, 2016. The proposedadditions to the building do not deviate from the granted exceptions and do notdrastically increase the risk to life safety as long as the following requirements areadhered to:
A. Building shall be of non-combustible construction.
B. Materials stored shall be limited to those previously approved.
C. Explosion proof electrical fixtures shall be used throughout.
D. Building shall be surrounded by 60' yards.
E. Building shall be fully equipped with a Very Early Smoke Detection and Alarm(VESDA) system.
F. Fire hydrant locations and flow rates shall be reviewed by a civil and/or fireprotection engineer. Required flow rate, unless a decrease is allowed by theAHJ, is 8,000 GPM for a 4 hour duration per NFPA Table B105.1. Hydrantlocations shall comply with City of Richland Fire Marshal requirements.
METAL PANEL WALL SYSTEM TO
BE REMOVED, 8' CONCRETE
WALL AND COLUMNS TO REMAIN
286' EXIT TRAVEL DISTANCE
156'-4"
G1.02
ELEVATIONS
SHEET NAME
DESIGNWEST
A R
C H
I T
E C
T S
,
P .
A .
A
B
C
D
E
F
10987654321
10987654321
A
B
C
D
E
F
SHEET
© C
OP
YR
IGH
T D
ES
IGN
WE
ST
AR
CH
ITE
CTS
P.A
. DE
SIG
N C
ON
CE
PTS
AN
D D
RA
WIN
GS
NO
T TO
BE
RE
US
ED
WIT
HO
UT
WR
ITTE
N P
ER
MIS
SIO
N O
F A
RC
HIT
EC
T
●
ME
RID
IAN
, ID
AH
O
● P
UL
LM
AN
, W
AS
HIN
GT
ON
●
●
KE
NN
EW
ICK
, W
AS
HIN
GT
ON
●
O
NT
AR
IO,
OR
EG
ON
●
ww
w.d
esig
nw
estp
a.c
om
DATE
06.02.20
CW
CP
FLAT
HO
USE
STO
RAG
E
RIC
HLA
ND
, WA
9935
433
34 L
OG
STO
N B
LVD
.
CHECKED BY
DRAWN BY
EB
AP
REVISIONS
JOB NUMBER20046
Aus
tin P
arke
r 6/
2/20
20 2
:58:
35 P
M
SCALE: NTS
A1 NORTH ELEVATION
SCALE: NTS
C1 SOUTH ELEVATION
SCALE: NTS
E1 EAST ELEVATIONSCALE: NTS
E6 WEST ELEVATION
METAL SIDING
EAST ADDITION EXISTING BUILDING WEST ADDITION
WEST ADDITION EXISTING BUILDING EAST ADDITION
METAL ROOFING METAL SIDING METAL ROOFING
METAL SIDING METAL ROOFINGCONCRETE WALL METAL SIDING METAL ROOFINGCONCRETE WALL
METAL SIDING METAL ROOFINGCONCRETE WALL
OVERHEAD DOOR
METAL SIDING METAL ROOFINGCONCRETE WALL
OVERHEAD DOOR
+/- 45'-0"
ME
AN
R
OO
F H
EIG
HT
8'-0"
EGRESS DOOR EGRESS DOOREXISTING EGRESS DOOREXISTING EGRESS DOOREXISTING EGRESS DOOR
Entry
Going Down
NextAccessAbove
D
D
DESIGN BY:
DRAWN BY:
CHECKED BY:
BY
AP
R.
DA
TE
SHEET NUMBER:
DE
SC
RIP
TIO
N
R
EU
SE
O
F D
RA
WIN
GS
TH
IS
D
OC
UM
EN
T, A
ND
T
HE
ID
EA
S A
ND
D
ES
IG
NS
IN
CO
RP
OR
AT
ED
HE
RE
IN
, A
S A
N IN
ST
RU
ME
NT
O
F P
RO
FE
SS
IO
NA
L S
ER
VIC
E, IS
T
HE
PR
OP
ER
TY
O
F J-U
-B
E
NG
IN
EE
RS
, In
c.A
ND
IS
N
OT
T
O B
E U
SE
D, IN
WH
OLE
O
R P
AR
T, F
OR
A
NY
O
TH
ER
P
RO
JE
CT
W
IT
HO
UT
T
HE
E
XP
RE
SS
WR
IT
TE
N A
UT
HO
RIZ
AT
IO
N O
F J-U
-B
E
NG
IN
EE
RS
, In
c.
NO
.B
Y
RE
VIS
ION
AP
R.
DA
TE
BY
AP
R.
DA
TE
JUB PROJ. # :
LAST UPDATED: 6/2/2020
C-2
INCH, SCALE ACCORDINGLYAT FULL SIZE, IF NOT ONE
ONE INCH
FILE :
\\JU
B.C
OM
\CE
NT
RA
L\C
LIE
NT
S\W
A\C
EN
TR
ALW
AC
OR
NP
RO
CE
SS
OR
S\P
RO
JEC
TS
\30-
20-0
28_B
LDG
EX
PA
NS
ION
\DE
SIG
N\C
AD
\SH
EE
T\C
-2.D
WG
Plo
t Dat
e:6/
2/20
20 2
:02
PM
Plo
tted
By:
Dar
ral M
oore
Dat
e C
reat
ed:5
/14/
2020
J-U-B ENGINEERS, INC.
Ken
new
ick,
WA
993
36S
uite
201
J-U
-B E
NG
INE
ER
S, I
NC
.28
10 W
. Cle
arw
ater
Ave
.
ww
w.ju
b.co
mF
ax: 5
09.7
36.0
790
Pho
ne: 5
09.7
83.2
144
CEN
TRAL
WAS
HIN
GTO
N T
RAN
SFER
TER
MIN
ALC
EN
TRA
L W
AS
HIN
GTO
N C
OR
N P
RO
CE
SS
OR
S
OV
ER
ALL
SIT
E L
AY
OU
T
30-20-028
DSM
DSM
----
C-2
N
600 120
SCALE IN FEET
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE
YOU DIG, GRADE, OR EXCAVATE FOR THE
MARKING OF UNDERGROUND MEMBER
UTILITIES
Call before you dig.
Know what's below .
R
TAX PARCEL NO:122083000002001(12.48 AC±)
Entry
Going Down
NextAccessAbove
D
D
D
DESIGN BY:
DRAWN BY:
CHECKED BY:
BY
AP
R.
DA
TE
SHEET NUMBER:
DE
SC
RIP
TIO
N
R
EU
SE
O
F D
RA
WIN
GS
TH
IS
D
OC
UM
EN
T, A
ND
T
HE
ID
EA
S A
ND
D
ES
IG
NS
IN
CO
RP
OR
AT
ED
HE
RE
IN
, A
S A
N IN
ST
RU
ME
NT
O
F P
RO
FE
SS
IO
NA
L S
ER
VIC
E, IS
T
HE
PR
OP
ER
TY
O
F J-U
-B
E
NG
IN
EE
RS
, In
c.A
ND
IS
N
OT
T
O B
E U
SE
D, IN
WH
OLE
O
R P
AR
T, F
OR
A
NY
O
TH
ER
P
RO
JE
CT
W
IT
HO
UT
T
HE
E
XP
RE
SS
WR
IT
TE
N A
UT
HO
RIZ
AT
IO
N O
F J-U
-B
E
NG
IN
EE
RS
, In
c.
NO
.B
Y
RE
VIS
ION
AP
R.
DA
TE
BY
AP
R.
DA
TE
JUB PROJ. # :
LAST UPDATED: 6/4/2020
C-3
INCH, SCALE ACCORDINGLYAT FULL SIZE, IF NOT ONE
ONE INCH
FILE :
\\JU
B.C
OM
\CE
NT
RA
L\C
LIE
NT
S\W
A\C
EN
TR
ALW
AC
OR
NP
RO
CE
SS
OR
S\P
RO
JEC
TS
\30-
20-0
28_B
LDG
EX
PA
NS
ION
\DE
SIG
N\C
AD
\SH
EE
T\C
-3.D
WG
Plo
t Dat
e:6/
4/20
20 2
:31
PM
Plo
tted
By:
Dar
ral M
oore
Dat
e C
reat
ed:6
/4/2
020
J-U-B ENGINEERS, INC.
Ken
new
ick,
WA
993
36S
uite
201
J-U
-B E
NG
INE
ER
S, I
NC
.28
10 W
. Cle
arw
ater
Ave
.
ww
w.ju
b.co
mF
ax: 5
09.7
36.0
790
Pho
ne: 5
09.7
83.2
144
CEN
TRAL
WAS
HIN
GTO
N T
RAN
SFER
TER
MIN
ALC
EN
TRA
L W
AS
HIN
GTO
N C
OR
N P
RO
CE
SS
OR
S
GR
AD
ING
PLA
N
30-20-028
DSM
DSM
----
C-3
N
600 120
SCALE IN FEET
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE
YOU DIG, GRADE, OR EXCAVATE FOR THE
MARKING OF UNDERGROUND MEMBER
UTILITIES
Call before you dig.
Know what's below .
R
TAX PARCEL NO:122083000002001(12.48 AC±)
SITE CLEARING AND EARTHWORK NOTES
TESTING
KEYED NOTES
BENCHMARK/DATUM:
BASIS OF BEARINGS:
GE
NE
RA
L S
TR
UC
TU
RA
L N
OT
ES
S1.0SHEET
DESIGNED BY:
QUALITY CHECK:
JOB NO.
FIELDBOOK
DRAWN BY:
DATE:
MO
NT
AN
A
WA
SH
IN
GT
ON
ID
AH
O
GR
EA
T F
ALLS
-B
OZ
EM
AN
-K
ALIS
PE
LL-S
HE
LB
Y
RE
V
DA
TE
LE
WIS
TO
N
SP
OK
AN
E
En
gin
ee
rin
g
tdh
engineering.com
NO
RT
H D
AK
OT
AW
AT
FO
RD
C
IT
Y
RE
VIS
IO
N
4-29-20
IS
SU
ED
F
OR
P
ER
MIT
CE
NT
RA
L W
AS
HIN
GT
ON
C
OR
N P
RO
CE
SS
OR
S
RIC
HL
AN
D, W
A
S20-062
4/29/20
GXG
TSB
LWF
FL
AT
HO
US
E S
TO
RA
GE
4/29/20
LEGEND AND ABBREVIATIONSGENERAL NOTES
INSPECTIONS
“” “
”.
CONCRETE
“” “
”.
CONCRETE REINFORCING
DESIGN LOADS
FOUNDATION AND SOIL PREPARATION
STRUCTURAL STEEL AND WELDING
DRAWING LEGEND
XSX.X
SX.XX