12
Field Sprayer Distribution Valves Original Mounting Instruction 67214600-100, version 1.00 GB - 01.2016 www.hardi-international.com

Field Sprayer Distribution Valves · Field Sprayer Distribution Valves Original Mounting Instruction 67214600-100, version 1.00 GB - 01.2016

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Field Sprayer Distribution Valves · Field Sprayer Distribution Valves Original Mounting Instruction 67214600-100, version 1.00 GB - 01.2016

Field Sprayer Distribution ValvesOriginal

Mounting Instruction67214600-100, version 1.00GB - 01.2016

www.hardi-international.com

Page 2: Field Sprayer Distribution Valves · Field Sprayer Distribution Valves Original Mounting Instruction 67214600-100, version 1.00 GB - 01.2016

We congratulate you for choosing a HARDI plant protection product. The reliability and efficiency of this product depend upon your care. The first step is to carefully read and pay attention to this mounting instruction. It contains essential information for the efficient use and long life of this quality product.

This mounting instruction is for sprayers with EFC distribution system. The number of distribution valves may vary.

Mounting Instruction FormalitiesThe original mounting instruction is approved and published in English. All other languages are translations of the original mounting instruction. In the event of any conflicts, inaccuracies or deviations between the English instruction and other languages, the English version shall prevail.

Illustrations, technical information and data in this book are assumed to be correct at the time of printing.

Published and printed by HARDI INTERNATIONAL A/S.

All rights reserved.

Page 3: Field Sprayer Distribution Valves · Field Sprayer Distribution Valves Original Mounting Instruction 67214600-100, version 1.00 GB - 01.2016

3

Instructions

Before Mounting

Mounting Kit

The delivered parts are to be mounted on your HARDI sprayer.

They are used for controlling the spray fluid when spraying.

Where on the Sprayer

At the rear of the sprayer.

Tools and Materials Needed

Page 4: Field Sprayer Distribution Valves · Field Sprayer Distribution Valves Original Mounting Instruction 67214600-100, version 1.00 GB - 01.2016

Instructions

4

Mounting Instructions

Mounting the Parts

Lift up the entire control unit with the black junction box facing away from the sprayer (towards you).

• The control unit is heavy, so get a helping hand.

Insert the red square pipe fully into the bigger square pipe pointing rearwards from the sprayer.

Keep loose cables away.

Page 5: Field Sprayer Distribution Valves · Field Sprayer Distribution Valves Original Mounting Instruction 67214600-100, version 1.00 GB - 01.2016

Instructions

5

For some sprayers, there are two square pipes on the control unit.

Tighten the two bolts to fasten the control unit.

For some sprayers, the distribution valves have a different outlook, if a PrimeFlow system is included.

Page 6: Field Sprayer Distribution Valves · Field Sprayer Distribution Valves Original Mounting Instruction 67214600-100, version 1.00 GB - 01.2016

Instructions

6

Remove the front cover of the black junction box by loosening the screws in the four corners.

• Turn off the power supply for the sprayer.

Lead the main cable with the 37-pin connector into the junction box through the hole in the left side.

This cable is connected to the JobCom on the sprayer.

Mount the black cable gland and the white nut to fasten the cable.

Now mount the 37-pin connector in the socket on the circuit board,

and secure it by tightening the small screws in each side.

The cable for the speed sensor, measuring the driving speed of the sprayer, is already attached to the main cable.

Now lead the speed sensor cable into the junction box as shown here.

Press the three conductors into the terminals.

Sequence from the left: Brown - Blue - Black.

Page 7: Field Sprayer Distribution Valves · Field Sprayer Distribution Valves Original Mounting Instruction 67214600-100, version 1.00 GB - 01.2016

Instructions

7

The flow sensor cable is already attached to the main cable.

Now connect it by assembling the two connectors.

The red hose for the pressure gauge at the front of the sprayer, measuring the spray pressure, is already attached to the main cable.

Now connect it to the T-piece at the end of the line of distribution valves.

• Note the path of the red hose in behind the U-clamps.

Page 8: Field Sprayer Distribution Valves · Field Sprayer Distribution Valves Original Mounting Instruction 67214600-100, version 1.00 GB - 01.2016

Instructions

8

Mount the front cover of the junction box.

Tighten the screws in all four corners.

Attach any loose cables with cable ties below or behind the control unit.

Page 9: Field Sprayer Distribution Valves · Field Sprayer Distribution Valves Original Mounting Instruction 67214600-100, version 1.00 GB - 01.2016

Instructions

9

Connect the liquid hoses on the right side of the control unit:

Remove the U-clamp.

Insert the hose connector in the pipe.

Mount the U-clamp.

A. Pressure hose

B. Return hose

Control unit is ready for use.

Mounting completed.

Page 10: Field Sprayer Distribution Valves · Field Sprayer Distribution Valves Original Mounting Instruction 67214600-100, version 1.00 GB - 01.2016

Instructions

10

Page 11: Field Sprayer Distribution Valves · Field Sprayer Distribution Valves Original Mounting Instruction 67214600-100, version 1.00 GB - 01.2016

Spare Parts Information

To see updated spare part information, visit the Agroparts website on the internet.

Here all parts information can be accessed in the spare parts catalog:

1. Go to www.agroparts.com, register for free and log in.

2. Select “HARDI” in the menu on the left.

3. Select “Spare parts catalogue” and find your spare part.

4. Online ordering is also possible.

5. Contact your HARDI dealer for further information on spare parts.

User Evaluation

Dear Reader,

We update our mounting instructions regularly. Your suggestions for improvement are appreciated and will help us to create ever more user-friendly instructions. Send us your suggestions to this e-mail address:

Thank you.

[email protected]

Page 12: Field Sprayer Distribution Valves · Field Sprayer Distribution Valves Original Mounting Instruction 67214600-100, version 1.00 GB - 01.2016

HARDI INTERNATIONAL A/S

Herthadalvej 10, DK-4840 Nørre Alslev, DENMARK