FDD LTE Radio Parameters Description Guide

Embed Size (px)

Citation preview

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    1/55

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    2/55

    Internal Use Only

    Contents

    Basic Cell Parameters

    Cell Selection and Reselection Parameters

    Random Access Parameters

    Paging Parameters

    Measurement Parameters

    Handoff Parameters

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    3/55

    Internal Use Only

    Basic Cell Parameters

    Physical Cell ID

    Parameter Description

    This parameter identifies a unique physical cell that can be included in only one cell

    group. A system provides a total number of 504 physical cell IDs, which are classified

    into 168 groups, each group containing three unique IDs.

    When configuring this parameter, ensure that physical cell IDs should be space

    multiplexing as planned.

    Value Range and Step Length

    Value Range: Int (0, 1, , 503)

    Default Value: 0

    Configuration Principles A physical cell ID should be uniquely assigned for the same frequency point in the same

    geographical area or in different PLMNs (especially at the cell edge).

    To separate the primary synchronous channels among adjacent cells, ZTE recommends

    you set them to 0, 1, and 2because a macro eNodeB consists of three cells.

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    4/55

    Internal Use Only

    Basic Cell Parameters

    CP Selection for Physical Channel

    Parameter Description

    This parameter indicates the cyclic prefix (CP) of the OFDM symbol, which is used to

    determine the total number of OFDM symbols within one slot. When this parameter is set to

    normal cyclic prefix, it implies that seven OFDM symbols are available within one slot.

    When this parameter is set to extended cyclic prefix, it implies that six OFDM symbols are

    available within one slot.

    he

    Value Range and Step Length

    Value Range: Enum (normal cyclic prefix, extended cyclic prefix)

    Default Value: normal cyclic prefix

    Configuration Principles

    The CP is dependent on the multipath delay of a radio channel. In the presence of either

    a large multipath delay or a large cell radius, extended cyclic prefixis recommended.

    The extended cyclic prefixoption can suppress radio interference caused by multipath

    delay, but suffering from lower system capacity; and therefore it is recommended that

    you set it to the default value.

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    5/55

    Internal Use Only

    Basic Cell Parameters

    Downlink System Bandwidth

    Parameter Description

    This parameter indicates the system bandwidth in the downlink, which is used to

    determine the frequency domain location of the downlink physical channel as well as

    downlink frequency allocation.

    Value Range and Step Length

    Value Range: Enum (6, 15, 25, 50, 75, 100) Unit: RB

    Default Value: 100

    Configuration Principles

    This parameter is dependent on the frequency bandwidth acquired by a mobileoperator. The downlink system bandwidth can either be identical to or different from

    the uplink system bandwidth.

    Modifying this parameter can have an impact on downlink resource allocation.

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    6/55

    Internal Use Only

    Basic Cell Parameters

    Uplink System Bandwidth

    Parameter Description

    This parameter indicates the system bandwidth in the uplink, which is used to determine

    the frequency domain location of the uplink physical channel as well as uplink frequency

    allocation.

    Value Range and Step Length

    Value Range: Enum (6, 15, 25, 50, 75, 100) Unit: RB

    Default Value: 100

    Configuration Principles

    This parameter is dependent on the frequency bandwidth acquired by a mobileoperator. The downlink system bandwidth can either be identical to or different from

    the uplink system bandwidth.

    Modifying this parameter can have an impact on uplink resource allocation.

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    7/55

    Internal Use Only

    Basic Cell Parameters

    Cell Max Transmit Power

    Parameter Description

    This parameter specifies the maximum available transmit power.

    Value Range and Step Length

    Value Range: Float (0, , 50) Step: 0.1 Unit: dBm

    Default Value: 43

    Configuration Principles

    The default value is intended to be used in the following environment:Object Value Object Value

    Site Spacing 800 m Frequency Spectrum 2.6 G

    BS Height 25 m Antenna Gain 18 dBiMaximum Transmit Power (UE) 24 dBm Body/Path Loss 3 dB

    Maximum Uplink Throughput at Cell

    Edge (UE Dynamic Scheduling)

    128 kbps Shadow Fade Margin 10 dB

    Maximum Downlink Throughput 800 kbps Penetration Loss 20 dB

    Maximum Throughput (UE Semi-

    Dynamic Scheduling)

    32 kbps

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    8/55

    Internal Use Only

    Basic Cell Parameters

    Cell Transmit Power

    Parameter Description

    This parameter specifies the used transmit power.

    Value Range and Step Length

    Value Range: Float (0, , 50) Step: 0.1 Unit: dBm

    Default Value: 43

    Configuration Principles

    For the environment information about the use of the default value, see page 7

    (Cell Max Transmit Power).

    This parameter is dependent on the cell radius and the planned downlinkthroughput at the cell edge. The greater the cell radius or the planned downlink

    throughput at the cell edge, the greater the value of this parameter is required.

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    9/55

    Internal Use Only

    Basic Cell Parameters

    Cell-specific Reference Signals Power

    Parameter Description

    This parameter specifies the absolute power value of the cell reference signal for each

    resource element.

    Value Range and Step Length

    Value Range: Int (-60, , 50) Unit: dBm Default Value: 6

    Configuration Principles

    For the environment information about the use of the default value, see page 7 (Cell Max

    Transmit Power).

    This parameter is dependent on cell coverage. The greater the cell coverage, the greaterthe value of this parameter is required. This parameter should be used for ensuring cell

    coverage while achieving the maximum power.

    A reference signal power value should be properly tuned in accordance with the required

    power of the downlink control channel at the cell edge based on the link estimation

    calculated by using such radio parameters as cell type, cell radius, and antenna height.

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    10/55

    Internal Use Only

    Basic Cell Parameters

    Switch for User Inactivity

    Parameter Description

    This parameter specifies whether to enable the USER INACTIVITY feature.

    Parameter Location in the OMC

    To find this parameter, choose Views> Configuration Management > LTENE> Global

    Parameters of eNodeB in the OMC.

    Value Range and Step Length

    Value Range: Enum (close, open)

    Default Value: close

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    11/55

    Internal Use Only

    Basic Cell Parameters

    User Inactivity Timer

    Parameter Description

    This parameter specifies the time interval at which the UE is in inactive state.

    Parameter Location in the OMC

    To find this parameter, choose Views> Configuration Management > LTENE> Global

    Parameters of eNodeB in the OMC.

    Value Range and Step Length

    Value Range: one second to 30 days

    Default Value: 10 minutes

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    12/55

    Internal Use Only

    Basic Cell Parameters

    Pmax

    Parameter Description

    This parameter specifies the maximum transmit power allowed for the UE configured on

    the higher layer.

    Value Range and Step Length

    Value Range: Int (-30, , 33) Unit: dBm

    Default Value: 23

    Configuration Principles

    For the environment information about the use of the default value, see page 7

    (Cell Max Transmit Power).

    This parameter is dependent on the cell radius and the planned uplink throughput

    at the cell edge. The greater the cell radius or the planned uplink throughput at the

    cell edge, the greater the value of this parameter is required.

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    13/55

    Internal Use Only

    Contents

    Basic Cell Parameters

    Cell Selection and Reselection Parameters

    Random Access Parameters

    Paging Parameters

    Measurement Parameters

    Handoff Parameters

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    14/55

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    15/55

    Internal Use Only

    Q_RxLevMinOffset

    Parameter Description

    This parameter indicates the offset of the minimum required received power level of

    the cell which satisfies the condition of being selected or reselected by UE. It will

    affect the minimum required received power level in the cell. Range of the

    parameter is actual value which equals to double of value in 36.331.

    Value Range and Step Length

    int (2, .., .16) step 2 unit dB

    Default value: 2

    Configuration Principles

    Offset to the signalled Qrxlevmin taken into account in the Srxlev evaluation as a

    result of a periodic search for a higher priority PLMN while camped normally in a

    VPLMN.For normal cases, the default value is recommended. For some higher

    priority PLMN scenario, the value could be greater than the default value.

    (Depending on the coverage, loading, requirements of the high priority PLMN.

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    16/55

    Internal Use Only

    Qhyst

    Parameter Description

    This parameter indicates the hysteresis value for cells. In cell-ranking criterion R of

    cell reselection, the R value of serving cell equals to the measured value plus the

    hysteresis value. For detail description please refer to TS 36.304.

    Value Range and Step Length int (0, 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20, 22, 24)

    Default value: 3

    Configuration Principles

    This specifies the hysteresis value for ranking criteria of serving cell. If a cell is

    ranked as the best cell the UE shall perform cell reselection to that cell.The default

    value is recommende to be used in normal cases.The greater is the value of this

    parameter, the harder to fullfill the reselection process.

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    17/55

    Internal Use Only

    Cell Selection and Reselection Parameters

    ThresholdServing_Low

    Parameter Description

    This parameter specifies the low threshold for the serving carrier when the low priority carrier or

    system is selected and the following conditions can be fulfilled:

    The cell without any high priority carrier or system can meet the cell reselection criteria for

    escalating to a higher priority.

    When the Treselectionthreshold is not exceeded, SServingCellis smaller than

    byThreshSvrLow while SnonServingCell,x(low priority carrier or system) is greater than

    byThreshSvrLow (including inter-frequency and inter-system).

    The UE has resided in the serving cell for more than one second.

    Value Range and Step Length

    Value Range: Int (0, , 62) Step: 2 Unit: dB

    Default Value: 0

    Configuration Principles

    This threshold is used when the UE evaluates and reselects a low-priority E-UTRAN or RAT

    frequency point as the serving frequency point.

    TheSServingCellthreshold is applicable to the serving cell. When this SServingCellthreshold

    is reached, it is likely that the cell reselection will be triggered.

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    18/55

    Internal Use Only

    Cell Selection and Reselection Parameters

    S_Intrasearch

    Parameter Description

    This parameter specifies the intra-frequency measurement trigger threshold for cell selection. The UE

    is used to determine whether to implement the intra-frequency measurement.

    Value Range and Step Length

    Value Range: Int (0, ..., 62) Step: 2 Unit: dB

    Default Value: 14

    Configuration Principles

    When the quality of the serving cell is greater than the S_intrasearchvalue, the UE does not

    implement the intra-frequency measurement.

    When the quality of the serving cell is equal to or smaller than the S_intrasearchvalue, the UE

    implements the intra-frequency measurement.

    Setting this parameter to a too small value will cause the UE to fail in implementing the intra-

    frequency measurement in a timely manner, and thus failing to reselect an adjacent intra-

    frequency cell.

    Setting this parameter to a too large value will cause the UE to waste battery resources.

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    19/55

    Internal Use Only

    Cell Selection and Reselection Parameters

    IntraQ_OffsetCell

    Parameter Description

    This parameter specifies the intra-frequency cell reselection offset that is used to tune

    adjacent cells using the R criteria, and therefore it is comparable to the Qhystparameter.

    Value Range and Step Length

    Value Range: Enum (-24,-22,-20, -18, -16, -14, -12, -10, -8, -6, -5, -4, -3, -2, -1, 0, 1,2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20, 22, 24) Unit: dB

    Default Value: 0

    Configuration Principles

    Do not set this parameter to a too large value. Otherwise, the serving cell is very poor,

    but cannot be reselected.

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    20/55

    Internal Use Only

    Cell Selection and Reselection Parameters

    Intra_Pmax

    Parameter Description

    This parameter specifies the maximum available uplink transmit power, depending on

    the UE type. It is used for intra-frequency cell reselection. If this parameter is void, the

    UE will follow its own capabilities for further handling.

    Value Range and Step Length Value Range: Int (-30..33) Unit: dBm

    Default Value: 23

    Configuration Principles

    For more information, see page 12 (Pmax). The Intra_Pmaxparameter is

    dependent on the configuration data of adjacent cells.

    Modifying this parameter can have an impact on SIB3.

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    21/55

    Internal Use Only

    Cell Selection and Reselection Parameters

    The Timer for Cell Reselection in Inter-frequency E-UTRAN

    Parameter Description

    This parameter represents an inter-frequency cell reselection timer. Within the

    TreselectionInterEUTRAN, a new E-UTRAN inter-frequency cell, which performs better

    than the serving cell using the R criteria, can be reselected as a new serving cell.

    Value Range and Step Length Value Range: Int (0, , 7) Unit: s

    Default Value: 1

    Configuration Principles

    This parameter is comparable to the tRslIntraEutra parameter, which represents

    an intra-frequency cell reselection timer. You can set it to a value that is equal to or

    slightly greater than the tRslIntraEutra parameter.

    Modifying this parameter can have an impact on SIB5.

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    22/55

    Internal Use Only

    Cell Selection and Reselection Parameters

    Intra-frequency Cell Reselection Priority

    Parameter Description

    This parameter specifies the priority for intra-frequency cell reselection. The smaller the value

    of this parameter, the lower the cell reselection priority is.

    Value Range and Step Length

    Value Range: Int (0, , 7) Step: 1 Default Value: 0

    Configuration Principles

    The UE can implement the cell reselection process for only E-UTRAN frequency points

    and inter-system frequency points that have acquired the priority based on the

    corresponding system information. However, the UE will never consider any blacklisted

    cell as a candidate for cell reselection.

    If an adjacent cell has higher priority than the serving cell during the cell reselection

    measurement, the UE will unconditionally enable the intra-system or inter-system

    measurement. A higher priority cell takes precedence during the cell reselection process.

    Modifying this parameter can have an impact on SIB3.

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    23/55

    Internal Use Only

    Cell Selection and Reselection Parameters

    Intra-frequency Neighbour CSG Cell Physical Identity Range

    Parameter Description

    This parameter specifies the total number of CSG cells in an intra-frequency neighboring

    CSG cell group.

    Value Range and Step Length

    Value Range: Enum (4, 8, 12, 16, 24, 32, 48, 64, 84, 96, 128, 168, 252, 504)

    Default Value: 4

    Configuration Principles

    If this parameter is void, it implies that only one CSG neighboring cell is present.

    The physical identify of this CSG cell is represented by the

    intraFreqCSGPhyCellId_lowest parameter.

    Modifying this parameter can have an impact on SIB4.

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    24/55

    Internal Use Only

    Contents

    Basic Cell Parameters

    Cell Selection and Reselection Parameters

    Random Access Parameters

    Paging Parameters

    Measurement Parameters

    Handoff Parameters

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    25/55

    Internal Use Only

    Random Access Parameters

    Key random access parameters include:

    Cell High-Speed Attribute

    Ncs Used to Generate PRACH Preamble

    Logical Root Sequence Start Number Used to Generate PRACH Preamble

    Number of Non-dedicated Random Access Preambles

    Size of Random Access Preambles Group A

    Threshold of Selecting Preamble Group

    Message Power Offset for Group B

    the Initial RB Number for Random Access Preambles

    PRACH Configuration Index PRACH

    Initial Power for Preamble of PRACH

    Power Ramping Step for PRACH

    Max retransmit number for PRACH

    TTI Window Size for PRACH Response

    Max Number of Messages HARQ Transmissions Message 3

    MAC Contention Resolution Timer

    Dedicated Preamble Life Time

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    26/55

    Internal Use Only

    Random Access Parameters

    Cell Radius

    Preamble

    Format

    RadiusThrdLR

    a (km)

    RadiusThrdH

    Ra (km)

    0 0 14

    1 29 77

    2 14 29

    3 77 100

    Cell High-Speed Attribute

    Default Value: Not high speed cellValue Range: Enum {Not high speed cell, high speed cell}

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    27/55

    Internal Use Only

    Random Access Parameters

    MTDT

    Preamble

    format

    MaxCellRadius

    (km)

    0 103.2768 97.0176 5.2 14.545367

    1 685.3824 516.384 16.7 77.418191

    2 203.424 197.1648 16.7 27.994603

    3 685.3824 716.6784 16.7 100.25223

    CPTGPT MTDT

    67.6/),min( GPMTDCPcell TTTR

    SequenceCP

    CPT SEQT

    Guard Pd

    GPT

    RTDT MTDT

    One slot

    s24576 T

    s3168 T

    s21024 T

    sT15360 sT15360 sT15360 sT15360

    s6240 T

    s24576 T s15840 T

    s6080 Ts24576 T s24576 T

    s21024 T s24576 T s24576 T

    sT15360 sT15360

    s24576 T

    s21993 T

    s2976 T

    One subframe (1ms)

    Format

    0

    Format

    1Format

    2

    Format

    3

    Cell Radius (Supported):

    015 km

    3077 km

    1530 km

    77100 km

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    28/55

    Internal Use Only

    for Preamble Generation (Preamble Formats 0-3)CSN

    Ncs

    configurati

    on

    Low and

    Medium

    Speed Ncs

    (

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    29/55

    Internal Use Only

    Logical root

    sequence number

    Physical root sequence number u

    (in increasing order of the corresponding logical sequence number)

    023 129, 710, 140, 699, 120, 719, 210, 629, 168, 671, 84, 755, 105, 734, 93, 746, 70, 769, 60, 779

    2, 837, 1, 838

    2429 56, 783, 112, 727, 148, 691

    204-263 152, 687, 144, 695, 134, 705, 138, 701, 199, 640, 162, 677, 176, 663, 119

    720, 158, 681, 164, 675, 174, 665, 171, 668, 170, 669, 87, 752, 169, 670, 88, 751, 107, 732, 81, 758, 82, 757, 100, 739, 98, 741,

    71, 768, 59, 780, 65, 774, 50, 789, 49, 790, 26, 813, 17, 822, 13, 826, 6, 833

    328383 225, 614, 224, 615, 221, 618, 220, 619, 127, 712, 147, 692, 124, 715, 193, 646, 205, 634, 206, 633, 116, 723, 160, 679, 186,

    653, 167, 672, 79, 760, 85, 754, 77, 762, 92, 747, 58, 781, 62, 777, 69, 770, 54, 785, 36, 803, 32, 807, 25, 814, 18, 821, 11, 828,

    4, 835

    384455 3, 836, 19, 820, 22, 817, 41, 798, 38, 801, 44, 795, 52, 787, 45, 794, 63, 776, 67, 772, 72, 767, 76, 763, 94, 745, 102, 737, 90,

    749, 109, 730, 165, 674, 111, 728, 209, 630, 204, 635, 117, 722, 188, 651, 159, 680, 198, 641, 113, 726, 183, 656, 180, 659,

    177, 662, 196, 643, 155, 684, 214, 625, 126, 713, 131, 708, 219, 620, 222, 617, 226, 613

    820-837 336, 503, 305, 534, 373, 466, 280, 559, 279, 560, 419, 420, 240, 599, 258, 581, 229, 610

    Root Zadoff-Chu Sequence Order for Preamble Format 03

    Random Access Parameters

    Logical Root Sequence Start Number Used to Generate PRACH

    Value Range: [0, ..., 837] Default Value: N/A

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    30/55

    Internal Use Only

    Random Access Parameters

    q Preamble Group B

    64 Preambles

    n Preamble Dedicated m Preamble Non-dedicated

    p Preamble Group A

    Number of Non-dedicated

    Random Access Preambles

    Default Value: 60

    Value Range: Enum {

    4, 8, 12, 16, 20, 24, 28, 32, 36,

    40, 44, 48, 52, 56, 60, 64}

    Size of Random Access

    Preambles Group ADefault Value: 56

    Value Range: Enum {

    4, 8, 12, 16, 20, 24, 28, 32, 36,

    40, 44, 48, 52, 56, 60}

    Threshold of Selecting

    Preamble GroupDefault Value: 144 bit

    Value Range: Enum {

    56, 144, 208, 256} bit

    Message Power Offset for

    Group BDefault Value: 0 dB

    Value Range: Enum {

    -infinity, 0, 5, 8, 10, 12, 15,

    18} dB

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    31/55

    Internal Use Only

    Random Access Parameters

    47

    PRB

    n

    48PRBn

    49PRBn

    Specifical

    subframe

    Uplink

    subframe

    7PRBn

    0

    PRB

    n

    1PRBn

    2PRBn

    8PRBn

    ...

    SR

    PUSCH

    DMRS

    CCR#0 data: CQI

    CCR#2 data: ACK/NACK

    CCR#1 data: CQI

    CCR#3 data: ACK/NACK

    CCR#0 pilot: CQI

    CCR#2 pilot: ACK/NACK

    CCR#1 pilot: CQI

    CCR#3 pilot: ACK/NACKRACH

    Initial RB Number for

    Random Access Preambles

    Value Range: [0, , 94]

    Default Value: Void

    PRACH Configuration Index

    Value Range: [0, , 63]Default Value: 3

    nPRB=2

    60 ULRB NnRA

    PRBoffset

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    32/55

    Internal Use Only

    Random Access Parameters

    The number of randomaccessing based oncontention resolution

    Probability of RAcolliding

    Physical Cell ID

    Frame Structure Type 1 Random Access Configuration for Preamble Format 0

    PRACH Configuration Index Preamble Format System frame number Sub-frame number

    0 0 Even 1

    1 0 Even 4

    2 0 Even 7

    3 0 Any 1

    4 0 Any 4

    5 0 Any 7

    6 0 Any 1, 6

    7 0 Any 2 ,7

    8 0 Any 3, 8

    9 0 Any 1, 4, 7

    10 0 Any 2, 5, 8

    11 0 Any 3, 6, 9

    12 0 Any 0, 2, 4, 6, 8

    13 0 Any 1, 3, 5, 7, 9

    14 0 Any 0, 1, 2, 3, 4, 5, 6, 7, 8, 9

    15 0 Even 9

    Number of

    slots per

    second

    Prach Configuration Index

    Preamble Format 0 Preamble Format 1 Preamble Format 2 Preamble Format 3

    50 0, 1, 2, 15 16, 17, 18, 31 32, 33, 34, 47 48, 49, 50, 63

    100 3, 4, 5 19, 20, 21 35, 36, 37 51, 52, 53

    200 6, 7, 8 22, 23, 24 38, 39, 40 54, 55, 56

    300 9, 10, 11 25, 26, 27 41, 42, 43 57, 58, 59

    500 12, 13 28, 29 44, 45 N/A

    1000 14 N/A N/A N/A

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    33/55

    Internal Use Only

    Ramping Power (Configurable)

    T1 T2 T3 T4 T5 T6

    P0

    P0 +deta

    P

    P0 +2detaP

    P0 +3detaP

    P0 +5detaP

    Initial Power for Preamble of PRACH

    Default Value: -110 dBm

    Value Range: Enum {

    -120,-118,-116,-114-112-110-108-

    106-104-102-100-98-96-94-92-90} dBm

    Power Ramping Step for PRACH

    Default Value: 2 dB

    Value Range: Enum {0, 2, 4, 6} dB

    Max retransmit number for PRACH

    Default Value: 8

    Value Range: Enum {3, 4, 5, 6, 7, 8, 10, 20,

    50, 100, 200}

    PRACH = min{PcMAX, PREAMBLE_RECEIVED_TARGET_POWER + PL}

    PcMAX = Plmax + Pinitial + (N-1) * Step

    Random Access Parameters

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    34/55

    Internal Use Only

    Random Access Parameters

    Msg4: Contention Resolution

    Msg3: Scheduled Transmission

    Msg2: Random Access Response

    Msg1: Random Access Preamble

    UE eNodeBTTI Window Size for PRACH

    Response

    Default Value: 10ms

    Value Range: Enum {

    2, 3, 4, 5, 6, 7, 8, 10} ms

    Max Number of Messages

    HARQ Transmissions

    Default Value: 3

    MAC Contention Resolution

    Timer

    Default Value: 48sf

    Value Range: Enum {

    8, 16, 24, 32, 40, 48, 56, 64} sf

    Value Range: [1, , 8]

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    35/55

    Internal Use Only

    Random Access Parameters

    Msg3: Contention Requirement

    Data or Padding

    Msg2: RA Response

    Sent on PDSCH

    Msg1: Random Access Preamble

    Dedicated Preamble

    Msg0: PDCCH Order

    Dedicated Preamble ID, Mask Index

    UEeNodeB

    0

    1

    2

    3

    Dedicated Preamble Life Time

    Default Value: 100 ms

    Value Range: [0, , 100] ms

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    36/55

    Internal Use Only

    Contents

    Basic Cell Parameters

    Cell Selection and Reselection Parameters

    Random Access Parameters

    Paging Parameters

    Measurement Parameters

    Handoff Parameters

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    37/55

    Internal Use Only

    Paging Parameters

    DRX Cycle for Paging

    Parameter Description

    This parameter specifies the DRX cycle for paging purposes.

    Value Range and Step Length

    Value Range: Enum (32, 64, 128, 256) Unit: Sub-frame

    Default Value: 128

    Configuration Principles

    When the UE is in idle state but the DRX is being used, the UE needs to monitor a

    P-RNTI in a paging occasion every DRX cycle.

    Modifying this parameter can have an impact on other UEs being in idle state.

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    38/55

    Internal Use Only

    Paging Parameters

    nB used to derive the Paging Frame and Paging Occasion

    Parameter Description

    This parameter specifies the nB that is used to derive the paging frame and paging

    occasion, as defined in TS36.304.

    Value Range and Step Length

    Value Range: Enum (4T, 2T, T, 1/2T, 1/4T, 1/8T, 1/16T, 1/32T) Default Value: T

    Configuration Principles

    This parameter is an integer multiplied by T.

    T represents a paging cycle. For example, 2T indicates two paging cycles and 4T

    indicates four paging cycles.

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    39/55

    Internal Use Only

    Paging Parameters

    The Parameter to Determine BCCH Modification Period

    Parameter Description

    This parameter is used to determine the BCCH modification period (BCCH modification

    period = N * DRX cycle length for paging). The purpose of this constraint is to ensure

    that all the UEs being in idle state can monitor the system broadcast change message.

    Value Range and Step Length Value Range: Enum (2, 4, 8, 16)

    Default Value: 4

    Configuration Principles

    The greater this parameter, the longer the system message is updated. This can

    have an adverse impact on real-time message update.

    The smaller this parameter, the shorter the system message is updated. This can

    cause the UE to monitor the systemInfoValueTagmore frequently.

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    40/55

    Internal Use Only

    Contents

    Basic Cell Parameters

    Cell Selection and Reselection Parameters

    Random Access Parameters

    Paging Parameters

    Measurement Parameters

    Handoff Parameters

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    41/55

    Internal Use Only

    Measurement Parameters

    Intra-Frequency Trigger Quantity

    Parameter Description

    This parameter specifies the measured value that is used for triggering an event.

    Value Range and Step Length

    Value Range: Enum (0, 1) 0=RSRP, 1=RSRQ

    Default Value: 0

    Configuration Principles

    RSRP is short for reference signal received power.

    RSRQ is short for reference signal received quality.

    When the UE detects that this parameter meets the threshold, it will trigger an intra-frequency cell measurement event.

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    42/55

    I t l U O l

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    43/55

    Internal Use Only

    Measurement Parameters

    Intra-Frequency Threshold for RSRP

    Parameter Description

    This parameter specifies the absolute RSRP threshold for the serving cell to decide

    whether to trigger an event (A1, A2, A3, A4, and A5).

    Value Range and Step Length

    Value Range: A1/A2/A4/A5 : Int (-140, , -44) Unit: dBm Value Range: A3: Float (-15, , 15) Step 0.5 Unit: dB

    Default Value: [-75 -100 3 -90 -110]

    Configuration Principles

    This parameter is valid only when the RptCriteria parameter is set to 0(Event triggered

    reporting). It is applicable to A1, A2, A3, A4, and A5 only. The A1 threshold is greater

    than the A2 threshold.

    Internal Use Only

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    44/55

    Internal Use Only

    Measurement Parameters

    Intra-Frequency A5 Threshold2 for RSRP

    Parameter Description

    This parameter specifies the second RSRP threshold for an adjacent cell to decide

    whether to trigger the A5 event .

    Value Range and Step Length

    Value Range: Int (-140, , -44) Unit: dBm Default Value: -90

    Configuration Principles

    This parameter is mapped to the values that are defined in the 3GPP TS36.331: -

    140 (0), -139 (1), , -44 (96). It should be noted that no value is mapped to 97.

    Based on the A5 definition, this parameter must be greater than the Intra-

    Frequency Threshold for RSRP parameter.

    Internal Use Only

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    45/55

    Internal Use Only

    Measurement Parameters

    Intra-Frequency Hysteresis

    Parameter Description

    This parameter specifies the hysteresis that is used to decide whether to trigger an event.

    Value Range and Step Length

    Value Range: Float (0, , 15) Step 0.5 Unit: dB

    Default Value:

    RSRP event-triggered reporting: [0 0 0 0 0]

    RSRP periodically triggered reporting: -

    RSRQ event-triggered reporting: [0 0 0 0 0]

    RSRQ periodically triggered reporting: -9

    Internal Use Only

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    46/55

    Internal Use Only

    Measurement Parameters

    Intra-Frequency Time to Trigger

    Parameter Description

    This parameter specifies the time difference between event occurrence and event reporting.

    Value Range and Step Length

    Value Range: Enum (0, 40, 64, 80, 100, 128, 160, 256, 320, 480, 512, 640, 1024, 1280,

    2560, 5120) Unit: ms

    Default Value: [256 256 256 256 256]

    Configuration Principles

    The greater this parameter is configured, the more stringent the event trigger

    requirements becomes. You need to configure this parameter based on the desirable

    requirements. Setting this parameter to a too large value will have an adverse impact on

    call quality.

    The UE will trigger an event reporting only when the actual time reaches the threshold of

    this parameter. This parameter is introduced to prevent the UE from any fraudulent

    reporting caused by jitter. When configuring this parameter, you need to take the DRX

    cycle into consideration.

    Internal Use Only

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    47/55

    Internal Use Only

    Measurement Parameters

    Intra-Frequency Reporting Interval for Event

    Parameter Description

    This parameter specifies the time interval at which measurement results are periodically

    reported after an event is triggered.

    Value Range and Step Length

    Value Range: Enum (120, 240, 480, 640, 1024, 2048, 5120, 10240, 60000, 360000,720000, 1800000, 3600000) Unit: ms

    Default Value: [1024 1024 1024 1024 1024]

    Configuration Principles

    When an event is triggered, the UE reports measurement results at time intervals. If

    the actual value reaches the threshold of this parameter, the UE will stop reportingany measurement result.

    This parameter is valid only when the RptCriteriaparameter is set to 0(event

    triggered reporting).

    This parameter must be greater than the TrigTimeparameter.

    Internal Use Only

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    48/55

    Internal Use Only

    Measurement Parameters

    Intra-Frequency Amount of Reporting for event

    Parameter Description

    This parameter specifies the maximum number of reporting measurement results after

    an event is triggered.

    Value Range and Step Length

    Value Range: Enum (1, 2, 4, 8, 16, 32, 64, Infinity) Default Value: [Infinity Infinity Infinity Infinity Infinity]

    Configuration Principles

    When an event is triggered, the UE reports measurement results at time intervals. If

    the actual number reaches the threshold of this parameter, the UE will stop

    reporting any measurement result.

    Do not set this parameter to a too large value because it is used for intra-frequency

    handoff.

    This parameter is valid only when the RptCriteriaparameter is set to 0(event

    triggered reporting).

    Internal Use Only

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    49/55

    Internal Use Only

    Contents

    Basic Cell Parameters

    Cell Selection and Reselection Parameters

    Random Access Parameters

    Paging Parameters

    Measurement Parameters

    Handoff Parameters

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    50/55

    Internal Use Only

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    51/55

    y

    Handoff Parameters

    Threshold

    A threshold is used to evaluate signal quality (A5: absolute threshold, A3: relative threshold).

    Hysteresis and Timer

    Hysteresis and timer are used to determine whether to start or stop an event.

    Hysteresis is used to retard the start or stop of an event based on a decisive inequation,

    which can greatly improve reliability for decision making. Hysteresis is normally used in

    conjunction with a threshold.

    A timer is used to evaluate time-based constancy of a certain state (including the start or

    stop of an event) for the purpose of improving accuracy and reliability for event reporting.

    For this reason, a timer is irrelevant to a threshold.

    Customized Handoff Compensation

    It can be used to compensate either a serving or adjacent cell.

    When being added to the measured value of a serving cell, a positive compensation

    value is used to prohibit a handoff.

    When being added to the measured value of an adjacent cell, a positive compensation

    value is used to trigger a handoff.

    Internal Use Only

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    52/55

    y

    Handoff Parameters

    Time to Trigger

    Parameter Description

    This parameter specifies the time difference between event occurrence and event reporting.

    Value Range and Step Length

    Value Range: Enum (0, 40, 64, 80, 100, 128, 160, 256, 320, 480, 512, 640, 1024, 1280,

    2560, 5120) Unit: ms

    Configuration Principles

    This parameters is used to determine the time required for reporting an event, at which

    the measured value meets the event reporting criteria.

    The UE will trigger an event reporting only when the actual time reaches the threshold of

    this parameter. This parameter is introduced to prevent the UE from any fraudulent

    reporting caused by jitter. When configuring this parameter, you need to take the DRX

    cycle into consideration.

    You can set this parameter to a greater value for a low-speed cell. This can avoid any

    Pingpong reporting of measurement results due to signal jitter.

    Internal Use Only

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    53/55

    y

    Handoff Parameters

    Hysteresis

    Parameter Description

    This parameter specifies the hysteresis for event reporting decision in order to avoid jitter.

    Value Range and Step Length

    Value Range: Enum (0, 0.5, , 15) Step: 0.5 Unit: dB

    Configuration Principles

    Setting this parameter to a too large value will increase difficulty in triggering an

    event; however, setting this parameter to a too small value will result in the

    Pingpong effect.

    This parameter is comparable to the A3 Offset parameter. Meanwhile, it can be

    used to avoid frequent measurement reporting.

    Internal Use Only

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    54/55

    Handoff Parameters

    Report On Leave

    Parameter Description

    This parameter indicates an A3 event is leaving. It can be used to determine whether the

    UE needs to report an event when the A3-2 criteria is satisfied.

    Value Range and Step Length

    Value Range: Enum (false, true) Default Value: false

    Configuration Principles

    When this parameter is set to true, the UE will report an event if a cell meets the

    A3-2 criteria.

    You do not need to set this parameter is set to trueif handoff is triggered by only

    one measurement event reporting.

    This parameter is valid for the ICIC feature, in which case you need to set this

    parameter to trueso that the base station can monitor the UEs profile change.

    Internal Use Only

  • 8/10/2019 FDD LTE Radio Parameters Description Guide

    55/55