20
Ventilation Solutions Book January 2000 • SB-0100

Fantech Solutions Bookep.yimg.com/ty/cdn/rewilliams/fantechsolutions.pdf · Ventilation Kit the Fantech Vent Light will provide whisper quiet removal of moist, humid air from your

  • Upload
    others

  • View
    8

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Fantech Solutions Bookep.yimg.com/ty/cdn/rewilliams/fantechsolutions.pdf · Ventilation Kit the Fantech Vent Light will provide whisper quiet removal of moist, humid air from your

VentilationSolutions

BookJanuary 2000 • SB-0100

Page 2: Fantech Solutions Bookep.yimg.com/ty/cdn/rewilliams/fantechsolutions.pdf · Ventilation Kit the Fantech Vent Light will provide whisper quiet removal of moist, humid air from your

Table of Contents

Bathroom Ventilation Solutions .................................................................................................. 1

Vent Light ............................................................................................................................................... 5

Kitchen Ventilation Solutions ........................................................................................................ 7

Dryer Boosting Solutions ............................................................................................................. 11

Fan Sizing Guidelines ..................................................................................................................... 15

External Rotor Motor .................................................................................................................... 16

Page 3: Fantech Solutions Bookep.yimg.com/ty/cdn/rewilliams/fantechsolutions.pdf · Ventilation Kit the Fantech Vent Light will provide whisper quiet removal of moist, humid air from your

Whether your bathroom is basic or lavish,ask for a quiet, efficient Fantech exhaust fan.

Fantech Solutions Book 3

Page 4: Fantech Solutions Bookep.yimg.com/ty/cdn/rewilliams/fantechsolutions.pdf · Ventilation Kit the Fantech Vent Light will provide whisper quiet removal of moist, humid air from your

Hot air and steam vented

through roof ventFantechFR SeriesFan

Dual vent points, onefor each bathroom

Bath #1

Bath #2

Two Baths… One Solution!Think bathroom exhaust fans haveto be loud to be effective?

Think again.Do bathroom fans have to sound like a wind tunnel to get the job

done? The truth is, noisy bathroom exhaust fans loose much of their

effectiveness, simply because people don’t want to use them. So, odor,

moisture, mold and mildew build up. Even the most elegant bathrooms

become unattractive, and may suffer long-term damage.

Fantech bathroom exhaust fans are designed to operate quietly and ef-

fectively, so people actually use them. Yet their affordability means they’re

right for every bathroom—from simple to luxurious.

Requested by clients.Specified by designers.You’ll find Fantech bathroom exhaust fans specified on the blueprints

of top architects and designers.

Why? Simple. They’re quiet, efficient and reliable, and they’re easy to

install. Better still, Fantech offers a choice of interior and exterior mounted

fans. So there’s a Fantech bathroom exhaust fan for every situation.

Fantech FR Series Fan Kits.

A breath of fresh air.Fantech FR Series fans are available as easy-to-install kits. This de-

pendable family of bathroom fans offers a choice of single or dual

point exhaust. The kits include all basic components- the only addi-

tional elements required to complete the installation are flexible

duckwork and a roof or side vent. All FR Series fan kits feature fan,

mounting bracket and grill/collar/backdraft damper combination, and

all kits are prewired for easy connection to your electrical source.

Available to fit 4" to 8" duct sizes, Fantech FR Series regular (single

point exhaust) and deluxe (dual point exhaust) fan kits are the solution

for most bathroom ventilation needs.

RVF Series Fan

Fantech’s Deluxe Bathkit

includes all the items pic-

tured at left. Fan, Mount-

ing Bracket, Screws, Ap-

propriate sized Y-Joint for

duct, Two Adjustable Ceil-

ing Grills, Plastic Duct

Clips to secure your duct

to the fan and Y-joint and

Backdraft Damper.

RE Series Fan

Fantech’s RVF and RE Series Fans.

The easy exterior solution.When bathroom ventilation requirements call for an exterior mounted

fan, Fantech’s RVF and RE Series fans fit the bill. These fans are the

answer for apartments and condominiums, where concrete firewalls

separate the individual units.

The RVF fans mount on outside walls, RE fans on the roof or wall, for

minimal interior disturbance and maximum ventilation. Performance

levels match those of Fantech’s interior mounted fans.

The RVF and RE series features rugged construction with baked pow-

der-coat finish on a galvanized steel housing, dependability, and the

ability to withstand a wide range of temperatures. With duct diameters

from 4″ to 6″, there’s an RVF or RE Series fan to fit every need that

calls for exterior mounted ventilation.

4 Fantech Solutions Book

Page 5: Fantech Solutions Bookep.yimg.com/ty/cdn/rewilliams/fantechsolutions.pdf · Ventilation Kit the Fantech Vent Light will provide whisper quiet removal of moist, humid air from your

Exterior wall mounted RVF Series Fan

Inlet #1 of adual inlet system

Exterior roof mountedRE Series Fan

Fantech Solutions Book 5

Page 6: Fantech Solutions Bookep.yimg.com/ty/cdn/rewilliams/fantechsolutions.pdf · Ventilation Kit the Fantech Vent Light will provide whisper quiet removal of moist, humid air from your

RVF Series Fans Technical DataAll dimensions in inches.

RE Series Fan Technical DataAll dimensions in inches.

Dimensional Data

Please note: The Home Ventilation Institute (HVI) doesnot currently have a sound test standard for remotemounted fans. Fantech fans are considered remotemounted fans because they are not mounted within theliving area. As a result, Fantech is unable to list sonelevels for our products. In most cases, a remote fan willbe quieter than one mounted within the living area.

b c

model D d1 d2 a b cFR100 9¹|₂ 3⁷|₈ 4⁷|₈ 5¹|₄ ⁷|₈ ⁷|₈

FR110 9¹|₂ 3⁷|₈ 4⁷|₈ 5¹|₄ ⁷|₈ ⁷|₈

FR140 11³|₄ 5⁷|₈ 6¹|₄ 5⁷|₈ 1 ⁷|₈

FR150 11³|₄ 5⁷|₈ 6¹|₄ 5⁷|₈ 1 ⁷|₈

FR200 13¹|₄ 7⁷|₈ 9⁷|₈ 6¹|₄ 1¹|₂ 1¹|₂

D

d2 d1

a

FR Series Bathroom Ventilation Kits Technical DataAll dimensions in inches.

All fans 115 volts.

FR Series performance is shown with ducted outlet. Per HVI’s Certified

Ratings Program, charted air flow performance has been derated by a

factor based on actual test results and the certified rate at .2 inches WG.

Performance DataKit Fan Max. Max. Max. CFM @ CFM @ Duct Bathroom Mutiple Rooms

Model Model RPM Watts Amps 0” Ps .2” Ps Dia. Area Combined sq. ft.

REG100 FR100 2865 42 0.44 108 90 4″ Up to 85 ft2 —

DLX110 FR110 2761 75 0.67 167 150 4″ Up to 125 ft2 Up to 125 ft2

REG140 FR140 2832 60 0.52 214 190 6″ 85 to 180 ft2 —

DLX150 FR150 2411 90 0.78 243 220 6″ 140 to 210 ft2 125 to 180 ft2

DLX200 FR200 2507 123 1.07 408 360 8″ 210 to 350 ft2 180 to 340 ft2

d

c

e

a

b

2³|₄

Fan Max. Max. Max. CFM @ CFM @ Duct Bathroom Mutiple RoomsModel RPM Watts Amps .1″ Ps .2″ Ps Dia. Area Combined sq. ft.RVF-4 2970 44 0.51 110 98 4″ Up to 85 ft2 Up to 65 ft2

RVF-4XL 2690 92 0.84 180 172 4″ 85 to 140 ft2 65 to 125 ft2

RVF-6 2570 93 0.84 220 204 6″ 140 to 210 ft2 125 to 180 ft2

RVF-6XL 3000 157 1.46 360 346 6″ 210 to 330 ft2 180 to 290 ft2

All fans 115 volts.RVF Series performance is shown with ducted inlet. Per HVI’s Certified RatingsProgram, charted air flow performance has been derated by a factor based on actualtest results and the certified rate at .1 inches WG.

Performance Data

Dimensional Datamodel a b c d eRVF-4 10¹⁄₄ 13 6 1¹|₂ 3⁷⁄₈

RVF-4XL 10¹⁄₄ 13 6 1¹⁄₂ 3⁷⁄₈

RVF-6 10¹⁄₄ 13 6 1¹|₂ 5⁷⁄₈

RVF-6XL 14¹⁄₄ 17 6 1¹|₂ 5⁷⁄₈

Fan Max. Max. Max. CFM @ CFM @ Duct Bathroom Mutiple RoomsModel RPM Watts Amps 0″ Ps .25″ Ps Dia. Area Combined sq. ft.

RE-6 2695 87 0.76 227 199 6″ 140 to 210 ft2 125 to 180 ft2 Fan 115 volts.

Performance Data (For sound performance data refer to publication #RE/C-0799-4)

Dimensional Datamodel a b c d

RE-6 13 ³|₁₆ 6¹|₂ 15¹|₂ 6

a

dc

b

Fantech, Inc. certifiesthat the RE Series shownherein is licensed to bearthe AMCA Seal. The rat-ings shown are based ontests and proceduresperformed in accor-dance with AMCA Publi-cation 211 and AMCAPublication 311 andcomply with the require-ments of the AMCA Cer-tified Ratings Program.

Speed (RPM) shown is nominal. Performance is based on actual speed of test. Performance ratings do not include the effects of appurtenances in the airstream. Performance

is shown for installation Type A: Free inlet, Free Outlet.

6 Fantech Solutions Book

Page 7: Fantech Solutions Bookep.yimg.com/ty/cdn/rewilliams/fantechsolutions.pdf · Ventilation Kit the Fantech Vent Light will provide whisper quiet removal of moist, humid air from your

Fantech Vent Light

A Beautiful Solution

to Your Shower

and Bathroom

Ventilation

Problems

Fantech Solutions Book 7

Page 8: Fantech Solutions Bookep.yimg.com/ty/cdn/rewilliams/fantechsolutions.pdf · Ventilation Kit the Fantech Vent Light will provide whisper quiet removal of moist, humid air from your

Fantech, your ventilation solutions company, sets a new

standard in bathroom ventilation. Our Fantech Vent Light

is the latest in our pursuit of a more perfect bathroom

environment. Designed as an visually unobtrusive vent,

the Fantech Vent Light also contains the latest in lighting

technology. Providing light and ventilation in one dy-

namic package.

The visually elegant outside appearance of the grill is not

everything. Behind the elegant grill, is sturdy galvanized

construction of both the damper and terminal box

(terminal box may be remote mounted for between

floor installations). Prewired for convenience, and ease

of installation, the Fantech Vent Light has UL and cUL

approvals (for wet locations) and is IC rated. The low

voltage halogen light can be dimmed or brighten with

the use of a standard dimmer control.

When used with any Fantech Remote Fan or Bathroom

Ventilation Kit the Fantech Vent Light will provide whisper

quiet removal of moist, humid air from your shower and

bathroom area. Truly a beautiful approach.

A picture is worth a thousand words. TheVLC vent is located top-center.

Fantech’s UL and cUL

approved Fantech Vent Light

is compatible with Fantech

Bathroom Ventilation Kits

and Fans. Utilizing standard

110v current the Fantech Vent

Light can be installed easily

and quickly by professionals

or homeowners alike.

Fantech Vent LightA Beautiful Solution to Your

Shower and Bath Ventilation

Problems

Dimmable low voltage

halogen light

Paintable high impactwhite plastic grill

Fantech Vent Light available as follows:

• VLC-64 – prewired vent light complete with backdraft

damper for either 4″ or 6″ round duct.

• REG-100L – 4″ bath kit with FR 100 fan and VLC 64

vent light.

• DLX-150L – 6″ bath kit with FR 150 fan, balancing “Y”

and two VLC 6 vent lights.

Patent Pending

8 Fantech Solutions Book

Page 9: Fantech Solutions Bookep.yimg.com/ty/cdn/rewilliams/fantechsolutions.pdf · Ventilation Kit the Fantech Vent Light will provide whisper quiet removal of moist, humid air from your

Think You've Exhausted All the Possibilitiesfor Quiet, Efficient Rangehood Ventilation?

Think Again.

Photo C

redit: KraftM

aid Cabinetry, Inc., M

iddlefield, Ohio 4

40

62

Fantech Solutions Book 9

Page 10: Fantech Solutions Bookep.yimg.com/ty/cdn/rewilliams/fantechsolutions.pdf · Ventilation Kit the Fantech Vent Light will provide whisper quiet removal of moist, humid air from your

How to Make a

Beautiful Kitchen

Work Beautifully.

Ask any master chef — or weekend cook — what

makes a kitchen beautiful. It's not just how it looks. It's

how it works.

Fantech kitchen exhaust fans are designed to make beau-

tiful kitchens work beautifully. And there's a Fantech ven-

tilation solution for almost every kitchen, from single-family

homes to high-rise apartments and condominiums.

Most kitchen exhaust fans are so loud and inefficient

that they're never used. So steam, smoke and grease

build up, and never go out. It's enough to drive even

the most determined cook out of the kitchen.

Fantech kitchen exhaust fans are a cook's silent part-

ner. They're quiet and reliable, easy to install, and economical to op-

erate. And because they're so efficient, they keep counters, walls, floors

and furnishings cleaner longer.

No wonder people who love kitchens — but hate to clean them —

are some of our biggest fans.Fantech's FX Series Fans.What’s special about Fantech’s FX Series fans? Plenty. Their rugged galva-

nized steel housing with baked powder coat finish makes them ideal for

commercial style code applications. FX Series fans are pre-wired and sup-

plied with a mounting bracket and external wiring box for easy installation.

Fantech's FKD Series Fans.Fantech FKD Series fans were specifically developed to bridge the gap

between centrifugal and axial fan applications. These mixed flow centrifu-

gal exhaust fans offer quiet performance and easy installation. FKD Series

fans can be mounted at any angle — horizontal, vertical or diagonal.

Automatic reset thermal overload protection.

Fantech's RVF and RE Series Fans.Tight space? Open up to new solutions with Fantech’s RVF

and RE Series fans. These exterior mounted fans are per-

fect for condominiums and apartment units, freeing up valu-

able interior space. Wall mounted RVF Series, or roof

mounted RE Series, are designed inside and out to be

quiet and dependable, All fans feature baked powder coat

finishes, galvanized steel housings and external rotor mo-

tor with automatic reset. Adjustable fan speed saves en-

ergy and money. Easy to install.

Whatever your choice for the job.

All Fantech Fans offer these features:• Galvanized steel housings with baked powder coat finish

• 100% speed controllable

• UL and cUL approved.

• Five Year Warranty.

FX Series

RVF Series – Cut-Away

FKD Series

REC 10XL

RE Series – Cut-Away

RE 6

RVF Series

RE Series

10 Fantech Solutions Book

Page 11: Fantech Solutions Bookep.yimg.com/ty/cdn/rewilliams/fantechsolutions.pdf · Ventilation Kit the Fantech Vent Light will provide whisper quiet removal of moist, humid air from your

There's a Fantech kitchen exhaust fan for

almost every rangehood – from residential

to commercial styles. So if you're tired of

noisy, inefficient fans, check out

the fans that move steam and

heat up and out, quickly and

quietly. Fantech kitchen

exhaust fans.

Photo C

redit: Robert O

rr & A

ssociates Architects, N

ew H

aven, Connecticut 0

6511

LD Duct Silencer

Fantech Solutions Book 11

Page 12: Fantech Solutions Bookep.yimg.com/ty/cdn/rewilliams/fantechsolutions.pdf · Ventilation Kit the Fantech Vent Light will provide whisper quiet removal of moist, humid air from your

12 Fantech Solutions Book

Air Performance Data (For sound performance data refer to publication #RE/C-0799-4)

RE Series Fans Technical DataAll dimensions in inches.

e*

dc

a

b

*This dimension for REC fans only.RE Series fans are mounted to a flat base.

Speed (RPM) shown is nominal. Performance is based on actual speed of test. Performance ratings do not include the effects of appurtenances in the airstream. Performance is shown for installation

Type A: Free inlet, Free Outlet.

Fantech, Inc. certifies that the RE Se-ries shown herein is licensed to bearthe AMCA Seal. The ratings shown arebased on tests and procedures per-formed in accordance with AMCA Pub-lication 211 and AMCA Publication 311and comply with the requirements ofthe AMCA Certified Ratings Program.

Note: RE fans

are built with

a flat base.

Dimensional Datamodel a b c d e*

RE-6 13³|₁₆ 6¹|₂ 15¹|₂ 6 1¹|₂

RE-8XL 15³|₄ 6 20 8 1¹|₂

RE-10XL 19³|₄ 11³|₄ 20 10 1¹|₂

Fan Max. Max. Max. CFM VS. STATIC PRESSURE Max.Model RPM Watts Amps 0″ .125″ .25″ .375″ .5″ .75″ 1.0″ 1.25″ 1.5″ 1.75″ Ps.

RE-6 2695 87 0.76 227 213 199 184 169 134 106 80 51 — 1.84″RE-8XL 2830 148 1.29 401 382 362 341 319 271 230 192 159 129 2.46″

RE-10XL 3250 394 3.43 753 737 721 705 690 656 622 586 548 508 4.03″

Performance shown is for installation type D - Ducted inlet, Ducted outlet. Speed (RPM) shown is nominal. Performance is based on actual speed of test. Performance ratings do not include the effects of

appurtenances in the airstream.

Air Performance Data (For sound performance data refer to publication #FX-0799)

FX Series Fans Technical DataAll dimensions in inches.

2″b c

a

d

D

Dimensional Data

LD Duct Silencer – Available for duct sizes from 4 to 12 inches.

Fantech, Inc. certifies that the FX Se-ries shown herein is licensed to bearthe AMCA Seal. The ratings shown arebased on tests and procedures per-formed in accordance with AMCA Pub-lication 211 and AMCA Publication 311and comply with the requirements ofthe AMCA Certified Ratings Program.

Fan Max. Max. Nom. CFM VS. STATIC PRESSURE Max. DuctModel Watts Amps RPM 0″ .125″ .25″ .375″ .5″ .75″ 1.0″ 1.25″ 1.5″ Ps Dia.FX6 84 0.74 2680 257 241 221 197 178 143 99 59 — 1.60″ 6″FX6XL 147 1.26 2930 392 368 346 326 305 263 228 191 150 2.27″ 6″FX8 119 1.02 2580 481 444 403 361 319 237 177 130 76 2.04″ 8″FX8XL 152 1.31 2930 521 496 469 440 411 345 282 231 180 2.29″ 8″FX10 147 1.27 2930 521 499 475 448 418 357 293 234 176 2.28″ 10″FX10XL 242 2.11 2460 590 565 541 519 496 442 394 339 290 2.79″ 10″FX12 196 1.70 2450 711 675 627 576 521 382 284 220 166 2.65″ 12″FX12XL 411 3.57 3280 801 783 765 747 729 692 655 611 566 3.69″ 12″

model D d a b cFX6 11¹|₂ 5⁷|₈ 6 ³|₄ ⁷|₈

FX6XL 13¹|₄ 5⁷|₈ 6¹|₂ 1 ³|₄

FX8 13¹|₄ 7⁷|₈ 6¹|₄ 1 ⁷|₈

FX8XL 13¹|₄ 7⁷|₈ 6¹|₄ 1 ⁷|₈

FX10 13¹|₄ 9⁷|₈ 6¹|₄ 1 1¹|₄

FX10XL 13¹|₄ 9⁷|₈ 6¹|₄ 1 1¹|₄

FX12 16 11⁷|₈ 8¹|₄ 1 1¹|₄

FX12XL 16 11⁷|₈ 8¹|₄ 1 1¹|₄

Speed (RPM) shown in nominal. Performance is based on actual speed of test. Performance ratings do not include the effects of appurtenances in the airstream. Performance shown is for

installation Type D: ducted inlet, ducted outlet.

FKD Series Fans Technical DataAll dimensions in inches.

Model a b c d e Weight FKD 12XL 12 17 ⁷|₈ 18 ⁷|₈ ⁷|₈ 1⁵|₈ 45 lbs.

Dimensional Data

Air Performance Data (For sound performance data refer to publication #FKD-0799)

a

d e

a b

c

Fantech, Inc. certifies that the FKD Se-ries shown herein is licensed to bearthe AMCA Seal. The ratings shown arebased on tests and procedures per-formed in accordance with AMCA Pub-lication 211 and AMCA Publication 311and comply with the requirements ofthe AMCA Certified Ratings Program.

Max. Max. Nom. CFM VS. STATIC PRESSURE Max.Model Volts Watts Amps RPM 0″ .125″ .25″ .375″ .5″ .75″ 1.0″ 1.25″ PsFKD12XL 115 500 4.80 1700 2016 1920 1832 1746 1649 1423 1066 606 1.52″

Fan Max. Max. Max. CFM VS. STATIC PRESSURE Max.Model RPM Watts Amps 0″ .1″ .2″ .4″ .6″ .8″ 1.0″ 1.2″ 1.4″ Ps.RVF-6 2379 93 0.84 242 220 204 177 150 123 71 17 — 1.27″RVF-6XL 3049 148 1.46 381 360 346 315 285 258 214 164 92 1.74″RVF-8XL 2927 150 1.42 435 410 392 348 312 282 237 180 128 1.82″

Dimensional Data

Air Performance Data

RVF Series Fans Technical DataAll dimensions in inches.

model a b c d e fRVF-6 10¹|₄ 13 6 1¹|₂ 6 2³|₄

RVF-6XL 14¹|₄ 17 6 1¹|₂ 6 2³|₄

RVF-8XL 14¹|₄ 17 6 1¹|₂ 8 2³|₄

f

e

d

c a

b

RVF Series performance is shown with ducted inlet. HVI’s Certified Rating Program, charted air flow performance has been derated by a factor based on actual test results and the certified rate at .1 inches WG.

2100

Page 13: Fantech Solutions Bookep.yimg.com/ty/cdn/rewilliams/fantechsolutions.pdf · Ventilation Kit the Fantech Vent Light will provide whisper quiet removal of moist, humid air from your

VENTILATION SOLUTIONS:How do you vent overlength dryer duct runs andincrease dryer efficiency and performance?

With a Fantech Dryer Booster.

Fully

Automatic

Fan Mounted

Pressure

Switch

Fantech Solutions Book 13

Page 14: Fantech Solutions Bookep.yimg.com/ty/cdn/rewilliams/fantechsolutions.pdf · Ventilation Kit the Fantech Vent Light will provide whisper quiet removal of moist, humid air from your

The Dryer Facts:When it comes to dryers, where is the perfect installation with little to noduct length? The reality which contractors and homeowners have towork with is far from perfect. A short dryer duct length is not alwayspossible. This is where Fantech Dryer Boosters can help.

Under prime conditions, residential and commercial clothes dryersshould dry clothing in a timely fashion. Problems occur when dryersare connected to long runs of duct work. This is the reason why mostresidential dryers are located against outside walls. The exhausted airis vented directly to the outside without complicated ducting to hinderthe performance of the dryer.

Many dryer installations do not allow direct venting and the typical resi-dential dryer cannot operate efficiently against the resistance createdby the necessary duct work. The results are longer drying times, higherenergy usage and costs, and excessive wear and tear on the dryer.

Some common examples are:• Basements that do not allow direct venting.

• Central interior located residential laundry rooms.

• Apartment complexes with centrally locatedlaundering areas.

• Apartment complexes with individual hook-upsfor dryers in each apartment.

TYPICAL FAN PROBLEMS:Conventional types of booster fans present the following.

• Their blades clog with lint

• The blower cannot handle the long runs of ductany better than the blower in the dryer

• The motor cannot handle the heated air fromthe dryer and tends to overload

• How to turn the booster fan on with the dryer

When to boost a dryer.Typical residential dryers are rated at 160cfm. However, boosting is generally needed in order to maintain a minimum

airflow of 100cfm as duct length increases and bends are introduced in the duct line.

Based on surveying the recommendations from dryer manufacturers, and local building codes in selected areas, dryer

boosting is typically required when the duct length exceeds the following:

Maximum duct No bends 1 bend 2 bends 3 bendslength with:25’ 20’ 15’ 10’

Fantech models DBF 110, DBF 4XL and RVF 4XL are all suitable for most dryer boosting applications. Generally the

models listed can be used for maximum duct length of 60 linear feet with a maximum of six elbows using four inch rigid

duct. For longer duct runs please contact our technical department for specific recommendations

Fully

Automatic

Fan Mounted

Pressure

Switch

14 Fantech Solutions Book

Page 15: Fantech Solutions Bookep.yimg.com/ty/cdn/rewilliams/fantechsolutions.pdf · Ventilation Kit the Fantech Vent Light will provide whisper quiet removal of moist, humid air from your

FANTECH SOLUTIONS:

A Word on Installation…

Easy!The secret is in the fully automatic pressure switch.

Whether you are installing our new inline Dryer

Booster fan, DBF 110 and DBF 4XL (complete with

switch) or the RVF 4XL (with separate switch) it is a

breeze. Designed to attach inline near the booster

fan the switch monitors dryer operation and will

activate the fan when the dryer comes on. Preset

to cycle in ten minute intervals the fan will stay on

until the dryer stops. All Fantech dryer booster fans

are suitable for rigid duct runs of up to 60 linear

feet with a maximum of six elbows. In all installations

there needs to be at least 15 linear feet of duct

between the booster fan and the dryer. In addition,

Fantech offers peace of mind with a Five Year

Warranty on all the fans featured.

Residential and CommercialFantech RVF 4XL Exterior Mounted Fan

The RVF Series exterior mounted fans addresses every situation.

The perfect solution for condominiums and apartment complexes

where concrete firewalls separate the individual units. Venting of inte-

rior dryers can now be accomplished easily with minimal interior dis-

turbance. The unit mounts neatly on the outside wall. The RVF matches

the same performance requirements as our inline fans. The enamel

finish on the RVF is as enduring as it is attractive. The energy savings

of the efficient drying of clothes when combined with our new DB10

pressure switch (mounts near fan) is a winning combination.

Patent Pending

CommercialFantech DBF 4XL Dryer Booster Fan

The DBF 4XL features a housing made from galvanized steel with a

powder coat, baked enamel finish suitable for most commercial appli-

cations. The fans can handle lengths of duct up to 60 feet and six

elbows. The backward inclined blades allow lint to pass through the

fan. The attached fully automatic pressure switch is mindful of your en-

ergy use, turning the fan off and on, in ten minute cycles, only while the

dryer is running.

Patent Pending

Patent Pending

ResidentialFantech DBF 110 Dryer Booster Fan

The DBF 110 Dryer Booster inline fan addresses every obstacle. A silent

partner for your dryer. The fan compensates for system duct losses and

allows the dryer to exhaust warm moist air as the manufacturer intended.

The fans can handle up to 60 feet of duct and six elbows. The backward

blades allow lint to pass through the fan. The attached fully automatic

pressure switch is mindful of your energy use, turning the fan off and on,

in ten minute cycles, only while the dryer is running.

Fantech Solutions Book 15

Page 16: Fantech Solutions Bookep.yimg.com/ty/cdn/rewilliams/fantechsolutions.pdf · Ventilation Kit the Fantech Vent Light will provide whisper quiet removal of moist, humid air from your

FR110 performance is shown with ducted outlet. Per HVI’s Certified Ratings Program, charted air flowperformance has been derated by a factor based on actual test results and the certified rate at .2 inches WG.

Air Performance Data

DBF 110 (FR110 Fan)

Dimensions

model D d a b cFR110 9¹|2 3⁷|₈ 5¹|₄ ⁷|₈ ³|₄

b c

All dimensions in inches.

a

d

D

Fan Max. Max. CFM VS. STATIC PRESSURE Max. DuctModel RPM Watts Amps 0” .2” .4” .6” .8” 1.0” 1.5” Ps Dia.

FR110 2761 58 – 75 0.72 167 150 133 113 88 63 4 1.60” 4”

Performance shown is for installation type D - Ducted inlet, Ducted outlet. Speed (RPM) shown is nominal. Performance isbased on actual speed of test. Performance ratings do not include the effects of appurtenances in the airstream.

Air Performance Data

DBF 4XL

model D d a b cDBF4XL 9¹|₂ 4 6 ⁷|₈ ⁷⁄₈

b c

aAll dimensions in inches.

d

D

2″

Fan Max. Max. Max. CFM VS. STATIC PRESSURE Max. DuctModel RPM Watts Amps 0” .125” .25” .375” .5” .75” 1.0” 1.25” Ps Dia.

DBF4XL 2800 75 0.67 148 139 130 120 111 90 68 42 1.65” 4”

Dimensions

RVF 4XL performance is shown with ducted inlet. Per HVI’s Certified Ratings Program, charted air flow performance hasbeen derated by a factor based on actual test results and the certified rate at .1 inches WG..

Air Performance Data

RVF 4XL

Dimensions

model a b c d e f gRVF 4XL 10¹|₄ 13 6 1¹|₂ 3⁷|₈ 2 ³|₄ 5¹|₂

a

b

c

d

f

e

All dimensions in inches.

Fan Max. Max. CFM VS. STATIC PRESSURE Max. DuctModel RPM Watts Amps 0” .1” .2” .4” .6” .8” 1.0” 1.2” 1.4” Ps Dia.

RVF4XL 2690 73 – 92 0.84 190 180 172 154 136 118 91 57 28 1.61” 4”

Dryer Boosting Fan Specifications

16 Fantech Solutions Book

Page 17: Fantech Solutions Bookep.yimg.com/ty/cdn/rewilliams/fantechsolutions.pdf · Ventilation Kit the Fantech Vent Light will provide whisper quiet removal of moist, humid air from your

Fantech Fan Sizing Guidelines

Bathroom Ventilation RatesThese are only recommendations, always check local codes first.

Bathrooms under 100 square feetFor a bathroom size under 100 sq. ft. the standard rule of thumbis one (1) cfm per square foot of bathroom

Example #1

Bathroom Ventilation Sound LevelsRemote mounted fans have the potential to be extremelyquiet provided they are mounted properly.

We recommend the following:

• Use of insulated flexible duct for the exhaust system.

• Placing at least 8 feet of duct between intake grill and fan.(insulated flexible duct allows sound from fan to dissapategradually so that it can not be heard in the bathroom.)

• If applicable use multiple intake points.

• Use low sound generation grills (such as the ones supplied inour bath ventilation kits).

Kitchen Ventilation RatesBefore selecting your kitchen ventilation fan check with localresidential codes. This will typically give you a minimum ventilationrate. Additionally, check the range manufacturer’s recommenda-tions for ventilation. If range manufacturer’s recommendations arenot available use these figures in calculating fan size.

Wall Mount Hood:• 100 cfm per foot of width

Example #4

Example #3

Kitchen Ventilation Sound Levels:

Fantech inline fans tend to be very quiet for range hood installa-tion, however to optimize this, please consider the followingsuggestions.

• Install a duct silencer. This will act like a muffler to preventsound generated by the fan from coming down the ductto the range.

• Install a speed controller. Often a smaller amount ofventilation will be sufficient, and by running the fan slowerit is possible to reduce the sound.

Island Mount Hood:• 150 cfm per foot of width

Example #5

Range Hood Dimensions

36″ wide by 18″ deep

Conversion#1

36″ = 3′

Calculation #1

3′ x 100 cfm per foot = 300 cfm

Range Hood Dimensions

36″ wide by 24″ deep

Conversion#1

36″ = 3′

Calculation #1

3′ x 150 cfm per foot = 450 cfm

(Note: ft2 = square feet)

8′ x 10′ bath with one toilet and one shower/tub

Calculation #1

8′ x 10′ = 80 square feet

Calculation #2

80 ft2 x 1 cfm/ft2 = 80 cfm

Bathrooms over 100 square feetIn bathrooms over 100 sq. ft. the cfm is calculated based on thefixtures in the bath. Toilets, showers, standard tubs and steamshowers† are allowed 50cfm for each fixture. Hot tubs arecalculated at 100cfm.

Example #2

11′ x 14′ bath with his & her toilets and a shower

Calculation #1

11′ x 14′ = 154 square feet

Calculation #2

50 cfm (his toilet) + 50 cfm (her toilet) + 50 cfm (shower) = 150 cfm

18′ x 22′ bath with his & her toilets, shower, and hot tub

Calculation #1

18′ x 22′ = 396 square feet

Calculation #2

50 cfm (his toilet) +50 cfm (her toilet) +

50 cfm ((shower) + 100 cfm (hot tub) = 250 cfm

†Note: We recommend that steam showers be vented using aseparate fan on a timer so that fan may be shut off duringshower use and then run afterward to dry the shower stall.

Bathroom Vent LocationsLocate the vent intake as close to the bath fixtures (toilets,showers, and hot tubs) as possible. Try to keep the vent as farfrom doors, operable windows and air supply registers as possible.The intent is to make the air flow across the room and removemoist, humid air from the appliance location. Remote fans allowthe use of multiple intakes with a single fan so that systems maybe more closely tailored to the individual room.

Additional Questions? Problems?

Please call our ventilation experts at:

800-747-1762

Fantech Solutions Book 17

Page 18: Fantech Solutions Bookep.yimg.com/ty/cdn/rewilliams/fantechsolutions.pdf · Ventilation Kit the Fantech Vent Light will provide whisper quiet removal of moist, humid air from your

Fantech External Rotor Motor

All Fantech fans, with the exception of the TurboFlo Series, are powered by an external rotor motorized impeller. Like every electric

motor our external rotor motor consists of a stator wound with copper wire and a rotor. The difference is that the rotor rotates

externally around the stator.

Mechanical AdvantagesThe complete fan unit, i.e. the small external rotor motor equipped with an impeller requires minimum space. The motor/impeller combination

is matched by the motor manufacturer for optimum performance. The unique integration of both rotating parts – the motor and the impeller

– permits precision balancing in two planes to DIN ISO 1940. Rather than cantilevering off a shaft, the impeller is centered over the bearings

in the motor, thereby reducing the load on the bearings. Both the motor and the impeller are directly in the air stream and are thus very

efficiently cooled resulting in minimum thermal stress on the bearings. The above design features significantly extends lift expectancy. The

bearings are lubricated for life and require no maintenance. Fantech offers a 3 or 5 year warranty covering the complete unit on all external

rotor motor powered fans.

Speed ControllabilityFantech’s external rotor motor powered fans are 100% speed controllable. The fan output can be adjusted with solid state speed controls,

transformers or variable frequency drives. The speed controllability of the Fantech fans is achieved through careful design: The rotor in the

air stream gives superior cooling, increasing the service factor. Most motors loose too much torque as the voltage is reduced, causing the

motors to stall or operation to be unstable if the voltage is reduced too far. As the voltage is reduced the motor rpm is not reduced much at

first but when voltage is reduced farther the fan will suddenly stop. The external rotor motors in the Fantech fans are designed for increased

torque at reduced rpm’s. There is enough torque available for the motor to turn the wheel and operate in a stable fashion even at very low

rpm’s. The backward curved impeller design in the Fantech fans have no unstable areas of operation at any point of operation or at any

voltage/rpm.

Motor ProtectionEquipping motors with current sensing overload protection is not sufficient for speed controlled motors. Fantech’s external rotor motors

are equipped with internal thermal protection. The thermal protection will automatically shut down the motor if the motor is overheating for

any reason. On single phase fans this protection is totally internal. On three phase fans the thermal contacts shall be wired to an external

contactor, in order to stop the motor if an overheating condition is encountered.

Suitability:Fantech external rotor motors are classified as enclosed and are suitable for continuous duty. Fantech does currently not offer any explosion

proof external rotor motors. Since the motors are in the air stream the maximum airstream temperature is typically limited to 140° F. The

motors are not corrosion proof, but very well protected against humidity, especially when running continuously.

• Impeller • Impeller • Rotor • Windings • Sealed Ball • Shaft • Stator • RotorFlange Laminations Bearings Laminations

18 Fantech Solutions Book

Page 19: Fantech Solutions Bookep.yimg.com/ty/cdn/rewilliams/fantechsolutions.pdf · Ventilation Kit the Fantech Vent Light will provide whisper quiet removal of moist, humid air from your

Commercial Fans from FantechPowerful Solutions for Your

Ventilation Needs

Commercial Fans from FantechPowerful Solutions for Your

Ventilation Needs

Page 20: Fantech Solutions Bookep.yimg.com/ty/cdn/rewilliams/fantechsolutions.pdf · Ventilation Kit the Fantech Vent Light will provide whisper quiet removal of moist, humid air from your

The Ventilation Solutions Company

©2000 Fantech Inc. All rights reserved.

UNITED STATES

1712 Northgate Blvd. • Sarasota, Florida 34234

Phone: (800) 747-1762 • Fax: (800) 487-9915

Phone: (941) 351-2947 • Fax: (941) 359-3828

Web Site: www.fantech-us.com

E-mail: [email protected]

CANADA

P.O. Box 41590 • Brampton, Ontario L6Z 4R1

Phone: (800) 407-6195 • Fax: (800) 407-8965