35 36 Fan Coil Units Fan Coil Units Midea Fan Coil Units have ceiling exposed type, ceiling concealed type, wall-mounted type and floor-standing type. The air volume ranges from 150CFM to 2200CFM. It is a highly versatile product suitable for hospitals, office buildings, hotels, airports and various other applications. Fan Coil Units M - K T3 E 2200 G100 Type Code Midea Static Pressure G12: 12Pa; G:30: 30Pa; G50: 50Pa; G70: 70Pa; G100: 100Pa; Fuction Code Nominal Air Volume (CFM) Chilled Fan Coil Unit Nomenclature

Fan Coil Units Nomenclature - آرن تهویهarentahvieh.arsampishro.com/.../uploads/pdf/Fancoil-1.pdf37 38 Fan Coil Units Fan Coil Units Product Lineup 2-Pipe FCUs Air volume (CFM)

  • Upload
    others

  • View
    55

  • Download
    0

Embed Size (px)

Citation preview

  • 35 36

    Fan

    Coil

    Uni

    ts

    Fan

    Coil

    Uni

    ts

    Midea Fan Coil Units have ceiling exposed type, ceiling concealed type, wall-mounted type and floor-standing type. The air

    volume ranges from 150CFM to 2200CFM. It is a highly versatile product suitable for hospitals, office buildings, hotels, airports and

    various other applications.

    Fan Coil UnitsM -K T3 E2200 G100

    Type Code

    Midea

    Static PressureG12: 12Pa; G:30: 30Pa; G50: 50Pa;G70: 70Pa; G100: 100Pa;

    Fuction Code

    Nominal Air Volume (CFM)

    Chilled Fan Coil Unit

    Nomenclature

  • 37 38

    Fan

    Coil

    Uni

    ts

    Fan

    Coil

    Uni

    ts

    Product Lineup

    2-Pipe FCUs

    Air volume (CFM)

    1-way cassette

    4-way cassette

    Wall mounted

    Ceiling & floor

    Floor standing

    150 200 250 300 400 450 500 600 750 800 850 900 950 1000 1200 1400 1500 1600 1800 2000 2200

    Compact 4-way cassette

    Duct

    High static pressure Duct

    4-Pipe FCUs

    Air volume (CFM)

    4-way cassette

    Duct

    200 300 400 500 600 750 800 850 950 1000 1200 1400 1500

    Compact 4-way cassette

    Note:

    The standard power supply for all fan coil units is 220V-240V/50Hz; 208-230V/60Hz can be customized for all fan coil units.

    450100 900250 1600 1800 2000 2200

  • 39 40

    Fan

    Coil

    Uni

    ts

    Fan

    Coil

    Uni

    ts

    Cassette Series

    300/400CFM

    600CFM

    Compact 4-way Cassette

    4-way Cassette

    1-way Cassette

    Compact design, ultra slim body with a minimum thickness of

    153mm, especially suitable for narrow ceiling, such as in lobbies

    and small meeting rooms.

    153mm UItra thin

    Min. 153mm Thickness

    One direction air flow guarantees quick cooling, flexible installa-

    tion positioning.

    One Direction Air Flow

    High-lift PumpStandard built-in drain pump with 750mm pump head.

    750mm

    Single direction airflow, flexibly installed in various corners

    One direction air flow

    Speci�cations

    Notes:1. H: High fan speed; M: Medium fan speed; L: Low fan speed.2. Cooling conditions: entering water 7°C, temperature rise 5°C, entering air temperature 27°C DB/19°C WB. Heating conditions: entering water 50°C, entering air temperature 20°C DB, the same water flow as the cooling conditions.3. Noise is tested in a semi-anechoic test room.

    Power supply

    Air flow (H/M/L)

    Cooling

    Heating

    Power input (H/M/L)

    Auxiliary electric heater (AEH)

    Sound pressure level (H/M/L)

    Fan motor

    Fan

    Coil

    Panel

    Body

    Pipe

    connections

    Capacity (H/M/L)

    Water flow rate

    Water pressure drop

    Capacity (H/M/L)

    Water pressure drop

    Type

    Quantity

    Type

    Quantity

    Row

    Max. working pressure

    Diameter

    Net dimensions (W×H×D)

    Packing size (W×H×D)

    Net weight

    Gross weight

    Net dimensions (W×H×D)

    Packing size (W×H×D)

    Net weight (non-AEH/with-AEH)

    Gross weight (non-AEH/with-AEH)

    Water inlet/outlet pipe

    Drain pipe

    V/Ph/Hz

    m3/h

    CFM

    kW

    L/h

    kPa

    kW

    kPa

    W

    W

    dB(A)

    MPa

    mm

    mm

    mm

    kg

    kg

    mm

    mm

    kg

    kg

    inch

    mm

    510/450/400

    300/270/240

    3.04/2.79/2.56

    520

    14

    5.13/4.69/4.04

    9

    32/22/15

    750

    36/34/32

    1

    2

    1180x25x465

    1232x107x517

    3.5

    5.2

    1054x153x425

    1155x245x490

    12.8/13.1

    16.6/17.1

    630/560/500

    370/330/300

    3.79/3.58/3.38

    650

    20

    6.41/5.86/5.11

    16

    40/30/25

    750

    37/35/34

    1

    2

    1180x25x465

    1232x107x517

    3.5

    5.2

    1054x153x425

    1155x245x490

    12.8/13.1

    16.6/17.1

    1000/880/800

    590/520/470

    5.709/4.85/4.36

    982

    20.2

    9.6/8.36/7.48

    18.1

    125/88/65

    /

    42/39/37

    4

    3

    1420×10×755

    1500×110×870

    9

    12

    1200×198×655

    1380×265×720

    32.6

    36.3

    220-240/1/50

    Low noise 3-speed fan motor

    1

    Centrifugal, forward-curved blades

    1.6

    Φ7

    RC1/2

    ODΦ25

    Model

    ModelNon-AEH MKC-300R-B MKC-400R-B MKC-600HRN4

    With-AEH MKC-300RA-B MKC-400RA-B /

    1-way Cassette

  • Fan

    Coil

    Uni

    ts

    Fan

    Coil

    Uni

    ts

    41 42

    4-way Cassette

    Various SelectionsVersions for 2/4 pipe systems.

    Versions for compact/normal size.

    4-way air supply panel is standard for 4-way cassette.

    360°air supply panel is standard for compact 4-way cassette.

    Stylish Panel with Large Air�ow Outlet

    4-way panel 360°panel

    For Compact Four-way Cassette: Extremely compact casing suits any

    room's decor and requires little space for installation on a low ceiling.

    Due to compact body and light weight, all models can be installed without

    a hoist.

    Safe factory-installed electric heater is optional.

    Extended drainage pan is optional.

    Wireless controller is standard, and wired controller is optional.

    Standard built-in drain pump with 750mm pump head for normal

    size and 500mm for compact size.

    575mm

    261mm

    575mm

    Compact Design, Easy Installation

    Various Accessories Selections

    High-lift Drain Pump

    Fresh air can enter through the cassette unit so you can enjoy even

    fresher air in a room.

    Fresh Air Intake

    750mm

    2-Pipe 4-Way Cassette

    Notes:1. H: High fan speed; M: Medium fan speed; L: Low fan speed.2. Cooling conditions: entering water 7°C, temperature rise 5°C, entering air temperature 27°C DB/19°C WB. Heating conditions: entering water 50°C, entering air temperature 20°C DB, the same water flow as the cooling conditions.3. Noise is tested in a semi-anechoic test room.

    Power supplyAir flow (H/M/L)

    Cooling

    Heating

    Power input (H/M/L)Auxiliary electric heater (AEH)Sound pressure level (H/M/L)Fan motor

    Fan

    Coil

    Panel

    Body

    Pipe connections

    Capacity (H/M/L)Water flow rateWater pressure dropCapacity (H/M/L)Water pressure drop

    TypeQuantityTypeQuantityRowMax. working pressureDiameterNet dimensions (W×H×D)Packing size (W×H×D)Net weightGross weightNet dimensions (W×H×D)Packing size (W×H×D)Net weight (non-AEH/with-AEH)Gross weight (non-AEH/with-AEH)Water inlet/outlet pipeDrain pipe

    V/Ph/Hzm3/hCFMkWL/hkPakWkPaWW

    dB(A)

    MPammmmmmkgkg

    mmmmkgkg

    inchmm

    1000/850/720590/500/4205.7/4.73/3.96

    980 23.8

    9.66/7.72/6.2716.4

    125/84/742100

    45/41/36

    840×230×840900×260×900

    25/2730/32

    220-240/1/501250/1060/900

    740/620/5307/5.62/4.72

    1204 25.2

    11.55/9.24/7.5111.8

    130/102/932100

    46/42/37Low noise 3-speed fan motor

    1Centrifugal, forward-curved blades

    12

    1.6Φ7

    950×45×9501035×90×1035

    69

    840×230×840900×260×900

    25/2730/32RC3/4

    ODΦ32

    1400/1190/1010820/700/590

    7.27/6.46/5.711250

    2712.42/9.93/8.07

    14.6150/124/106

    285047/43/38

    840×300×840900×330×900

    30.5/3336.2/39

    ModelNon-AEH MKA-600R MKA-750R MKA-850RWith-AEH MKA-600RA MKA-750RA MKA-850RA

    Power supplyAir flow (H/M/L)

    Cooling

    Heating

    Power input (H/M/L)Auxiliary electric heater (AEH)Sound pressure level (H/M/L)Fan motor

    Fan

    Coil

    Panel

    Body

    Pipe connections

    Capacity (H/M/L)Water flow rateWater pressure dropCapacity (H/M/L)Water pressure drop

    TypeQuantityTypeQuantityRowMax. working pressureDiameterNet dimensions (W×H×D)Packing size (W×H×D)Net weightGross weightNet dimensions (W×H×D)Packing size (W×H×D)Net weight (non-AEH/with-AEH)Gross weight (non-AEH/with-AEH)Water inlet/outlet pipeDrain pipe

    V/Ph/Hzm3/hCFMkWL/hkPakWkPaWW

    dB(A)

    MPammmmmmkgkg

    mmmmkgkg

    inchmm

    1600/1360/1150940/800/680

    8.22/7.39/6.541414 31.2

    13.85/11.08/914.8

    155/131/1062850

    48/44/39

    2

    30.5/3336.2/39

    220-240/1/502000/1700/14401180/1000/85010.39/9.25/8.2

    1787 44

    17.58/14.06/11.4234.7

    190/127/1092850

    49/45/40Low noise 3-speed fan motor

    1Centrifugal, forward-curved blades

    12

    1.6Φ7

    950×45×9501035×90×1035

    69

    840×300×840900×330×900

    30.5/3336.2/39RC3/4

    ODΦ32

    2550/2170/18401500/1280/108012.9/11.51/10.21

    2219 40

    17.6/14.08/11.4436.7

    190/136/109/

    50/46/41

    3

    31.836

    ModelNon-AEH MKA-950R MKA-1200R MKA-1500RWith-AEH MKA-950RA MKA-1200RA /

  • Fan

    Coil

    Uni

    ts

    Fan

    Coil

    Uni

    ts

    43 44

    4-Pipe 4-Way Cassette 2-Pipe Compact 4-Way Cassette

    4-Pipe Compact 4-Way Cassette

    Model

    Power supply

    Air flow (H/M/L)

    Cooling

    Heating

    Power input (H/M/L)

    Sound pressure level (H/M/L)

    Fan motor

    Fan

    Coil

    Panel

    Body

    Pipe

    connections

    Capacity (H/M/L)

    Water flow rate

    Water pressure drop

    Capacity (H/M/L)

    Water pressure drop

    Type

    Quantity

    Type

    Quantity

    Row

    Max. working pressure

    Diameter

    Net dimensions (W×H×D)

    Packing size (W×H×D)

    Net weight

    Gross weight

    Net dimensions (W×H×D)

    Packing size (W×H×D)

    Net weight

    Gross weight

    Water inlet/outlet pipe

    Drain pipe

    V/Ph/Hz

    m3/h

    CFM

    kW

    l/h

    kPa

    kW

    kPa

    W

    dB(A)

    MPa

    mm

    mm

    mm

    kg

    kg

    mm

    mm

    kg

    kg

    Inch

    mm

    MKD-300

    510/440/360

    300/260/210

    3/2.58/2.16

    516

    14

    4/3.5/3.08

    12

    50/40/30

    36/33/28

    MKD-400

    220-240/1/50

    680/580/480

    400/340/280

    3.7/3.18/2.66

    636

    15

    5.1/4.3/3.83

    13

    70/50/40

    42/39/32

    Low noise 3-speed fan motor

    1

    Centrifugal, forward-curved blades

    1

    2

    1.6

    Φ7

    647×50×647

    715×123×715

    2.5

    4.5

    575×261×575

    670×290×670

    16.5

    20

    G3/4

    ODΦ25

    MKD-500

    850/730/600

    500/430/350

    4.5/3.6/3.06

    774

    16

    6/4.76/4.07

    15

    95/53/42

    45/42/34

    ModelPower supplyAir flow (H/M/L)

    Cooling

    Heating

    Power input (H/M/L)Sound pressure level (H/M/L)Fan motor

    Fan

    Coil

    Panel

    Body

    Pipe connections

    Capacity (H/M/L)Water flow rateWater pressure dropCapacity (H/M/L)Water flow rateWater pressure drop

    TypeQuantityTypeQuantityRowMax. working pressureDiameterNet dimensions (W×H×D)Packing size (W×H×D)Net weightGross weightNet dimensions (W×H×D)Packing size (W×H×D)Net weight Gross weightWater inlet/outlet pipeDrain pipe

    V/Ph/Hzm3/hCFMkWl/hkPakWl/hkPaW

    dB(A)

    MPammmmmmkgkg

    mmmmkgkg

    Inchmm

    MKA-600F

    1150/800/690680/470/4105.1/4.08/3.76

    877 15

    6.67/5.87/5.07574 37

    170/120/8542/32/26

    MKA-750F220-240/1/50

    1460/1020/880860/600/510

    5.93/4.41/3.941020

    177.87/6.85/5.9

    677 41

    188/135/9044/34/28

    Low noise 3-speed fan motor1

    Centrifugal, forward-curved blades12

    1.6Φ7

    950×45×9501035×90×1035

    69

    840×300×840900×307×900

    3541

    Cold water: RC3/4; Hot water: RC1/2ODΦ32

    MKA-850F

    1480/1040/890870/610/520

    6.17/5.13/4.591061

    208.06/6.93/6.05

    693 39

    198/140/10046/36/30

    ModelPower supplyAir flow (H/M/L)

    Cooling

    Heating

    Power input (H/M/L)Sound pressure level (H/M/L)Fan motor

    Fan

    Coil

    Panel

    Body

    Pipe connections

    Capacity (H/M/L)Water flow rateWater pressure dropCapacity (H/M/L)Water flow rateWater pressure drop

    TypeQuantityTypeQuantityRowMax. working pressureDiameterNet dimensions (W×H×D)Packing size (W×H×D)Net weightGross weightNet dimensions (W×H×D)Packing size (W×H×D)Net weight Gross weightWater inlet/outlet pipeDrain pipe

    V/Ph/Hzm3/hCFMkWl/hkPakWl/hkPaW

    dB(A)

    MPammmmmmkgkg

    mmmmkgkg

    Inchmm

    MKD-300S

    510/440/360300/260/2102.5/2.2/1.76

    430 22

    3.7/3.29/2.92318 17

    50/40/3036/33/28

    MKD-400S220-240/1/50680/580/480400/340/2802.9/2.55/2.04

    499 16

    4.6/3.82/3.4396 23

    70/50/4042/39/32

    Low noise 3-speed fan motor1

    Centrifugal, forward-curved blades12

    1.6Φ7

    647×50×647715×123×715

    2.54.5

    575×261×575655×290×655

    16.520

    Cold water: G3/4; Hot water: G1/2ODΦ25

    MKD-500S

    850/730/600500/430/3503.5/2.87/2.15

    602 24

    5.1/4.03/3.52439 27

    95/65/5045/42/34

    Notes:1. H: High fan speed; M: Medium fan speed; L: Low fan speed.2. Cooling conditions: entering water 7°C, temperature rise 5°C, entering air temperature 27°C DB/19°C WB. Heating conditions: entering water 70°C, temperature drop 10°C DB, entering air temperature 20°C DB.3. Noise is tested in a semi-anechoic test room.

    Notes:1. H: High fan speed; M: Medium fan speed; L: Low fan speed.2. Cooling conditions: entering water 7°C, temperature rise 5°C, entering air temperature 27°C DB/19°C WB. Heating conditions(2 pipe): entering water 50°C, entering air temperature 20°C DB, the same water flow as the cooling conditions. Heating conditions(4 pipe): entering water 70°C, temperature drop 10°C DB, entering air temperature 20°C DB.3. Noise is tested in a semi-anechoic test room.

    ModelPower supplyAir flow (H/M/L)

    Cooling

    Heating

    Power input (H/M/L)Sound pressure level (H/M/L)Fan motor

    Fan

    Coil

    Panel

    Body

    Pipe connections

    Capacity (H/M/L)Water flow rateWater pressure dropCapacity (H/M/L)Water flow rateWater pressure drop

    TypeQuantityTypeQuantityRowMax. working pressureDiameterNet dimensions (W×H×D)Packing size (W×H×D)Net weightGross weightNet dimensions (W×H×D)Packing size (W×H×D)Net weight Gross weightWater inlet/outlet pipeDrain pipe

    V/Ph/Hzm3/hCFMkWl/hkPakWl/hkPaW

    dB(A)

    MPammmmmmkgkg

    mmmmkgkg

    Inchmm

    MKA-950F

    1720/1200/10301010/700/6106.7/5.48/4.85

    1152 22

    8.67/7.63/6.59746 42

    205/145/10547/38/32

    2

    3541

    MKA-1200F220-240/1/50

    1860/1300/11101090/760/6509.28/7.45/6.5

    1596 32

    11.65/10.49/8.851002

    57197/135/103

    48/40/34Low noise 3-speed fan motor

    1Centrifugal, forward-curved blades

    13

    1.6Φ7

    950×45×9501035×90×1035

    69

    840×300×840900×307×900

    3844

    Cold water: RC3/4; Hot water: RC1/2ODΦ32

    MKA-1500F

    2100/1470/12601230/860/74010.58/7.45/6.5

    1820 38

    12.62/11.36/9.471085

    61234/165/115

    50/42/36

    3

    3844

  • 45 46

    Duct Series DuctVarious Selections

    Versions for 2/4 pipe systems.

    Versions for normal/large temperature difference systems.

    2, 3 or 4 rows coil for 2-pipe systems.

    Large range of available static pressure.

    Wired controller is optional.

    Four fan speeds are avaliable: low, medium, high and one reserved for more choice.

    High E�ciency

    Standard Return Air Plenum and Filter

    Fresh air can enter through the duct unit so you can enjoy even

    fresher air in a room.

    Fresh Air Intake

    Left and right hand piping connections are optional, flexible installation.

    Flexible Installation

    Duct

    High Static Pressure Duct

    District Cooling Duct

    Standard return air plenum and filter guarantees clean air supply and stable air flow rate.

    Fan

    Coil

    Uni

    ts

    Fan

    Coil

    Uni

    ts

    Highly efficient heat exchange for complete contranatant flow.

    Left hand Right handFront discharge

  • 47 48

    2-Row Duct 3-Row Duct

    Non-AEH

    With-AEHPower supplyAir flow (H/M/L)

    Standard external static pressureCooling

    Heating

    Power input

    Auxiliary electric heater (AEH)Sound pressure levelFan motor

    Fan

    Coil

    Net dimensions (W×H×D)Packing size (W×H×D)Net weight (non-AEH/with-AEH)Gross weight (non-AEH/with-AEH)Water inlet/outlet pipeDrain pipe

    Capacity (H/M/L)Water flow rateWater pressure dropCapacity (H/M/L)Water pressure drop12Pa (H/M/L)30Pa (H/M/L)

    12Pa (H/M/L)30Pa (H/M/L)TypeQuantityTypeQuantityRowMax. working pressureDiameter

    V/Ph/Hzm3/hCFMPakWl/hkPakWkPaWWW

    dB(A)dB(A)

    MPammmmmmkgkg

    Inchmm

    340/255/170200/150/100

    2.2/1.9/1.68378 14

    3.5/3.08/2.5910.5

    33/25/2249/37/33

    55035/32/2641/37/31

    1

    741×241×522790×260×550

    14.6/16.116.9/18.4

    510/385/255300/225/150

    3.1/2.7/2.3533 26

    5.3/4.61/3.9821.8

    53/41/3564/49/42

    65036/33/2742/38/32

    2

    841×241×522890×260×550

    17/18.519.5/21

    220-240/1/50680/510/340400/300/200

    G12 models: 12; G30 models: 304/3.4/2.95

    688 18

    6.8/5.85/5.116.9

    66/53/4875/61/54

    110037/34/2843/39/33

    Low noise 3-speed fan motor1

    Centrifugal, forward-curved blades23

    1.6Φ9.52

    941×241×522990×260×550

    20.2/21.722.6/24.1

    RC3/4R3/4

    850/640/425500/375/250

    4.6/3.96/3.45791 24

    7.9/6.95/622.3

    87/53/4493/56/47

    110040/36/3044/40/34

    2

    941×241×522990×260×550

    20.2/21.722.6/24.1

    1020/765/510600/450/300

    5.8/4.88/4.45998 36

    9.8/8.6/7.431.6

    100/65/55114/74/63

    160042/38/3245/41/35

    2

    1161×241×5221210×260×550

    23/2526/28

    MKT3-200G12MKT3-200G30

    MKT3-200EG30

    MKT3-300G12MKT3-300G30

    MKT3-300EG30

    MKT3-400G12MKT3-400G30

    MKT3-400EG30

    MKT3-500G12MKT3-500G30

    MKT3-500EG30

    MKT3-600G12MKT3-600G30

    MKT3-600EG30Model

    Notes:1. H: High fan speed; M: Medium fan speed; L: Low fan speed.2. The data are test under standard external static pressure. 3. Cooling conditions: entering water 7°C, temperature rise 5°C, entering air temperature 27°C DB/19°C WB. Heating conditions: entering water 50°C, entering air temperature 20°C DB, the same water flow as the cooling conditions.4. Noise is tested in a semi-anechoic test room.

    Non-AEH

    With-AEHPower supplyAir flow (H/M/L)

    Standard external static pressureCooling

    Heating

    Power input

    Auxiliary electric heater (AEH)Sound pressure levelFan motor

    Fan

    Coil

    Net dimensions (W×H×D)Packing size (W×H×D)Net weight (non-AEH/with-AEH)Gross weight (non-AEH/with-AEH)Water inlet/outlet pipeDrain pipe

    Capacity (H/M/L)Water flow rateWater pressure dropCapacity (H/M/L)Water pressure drop12Pa (H/M/L)30Pa (H/M/L)

    12Pa (H/M/L)30Pa (H/M/L)TypeQuantityTypeQuantityRowMax. working pressureDiameter

    V/Ph/Hzm3/hCFMPakWl/hkPakWkPaWWW

    dB(A)dB(A)

    MPammmmmmkgkg

    Inchmm

    MKT3-800G12MKT3-800G30

    MKT3-800EG30

    MKT3-1000G12MKT3-1000G30

    MKT3-1000EG30

    MKT3-1200G12MKT3-1200G30

    MKT3-1200EG30

    MKT3-1400G12MKT3-1400G30

    MKT3-1400EG30Model

    1360/1020/680800/600/400

    8.2/6.88/6.251410

    3913.6/11.97/10.2

    33.8145/121/108154/129/114

    220043/39/3346/42/36

    1461×241×5221510×260×550

    31.9/34.435.5/38

    1700/1275/8501000/750/500

    9/7.8/6.571548

    3216/14.24/12

    30.7180/114/97180/114/97

    220045/41/3547/43/37

    1566×241×5221615×260×550

    34.4/37.438.1/41.1

    2040/1530/10201200/900/600

    11/9.8/8.351892

    3920.1/18.27/15.43

    34.6210/140/120220/147/126

    320046/42/3648/44/38

    1856×241×5221905×260×550

    39.5/4343/46.5

    2380/1785/11901400/1050/700

    12.5/10.8/9.442150

    4521/18.7/15.75

    40.1222/179/155278/224/194

    320048/44/3849/45/39

    2022×241×5222070×260×550

    43.1/47.148.4/52.4

    220-240/1/50

    G12 models: 12; G30 models: 30

    Low noise 3-speed fan motor2

    Centrifugal, forward-curved blades43

    1.6Φ9.52

    RC3/4R3/4

    Notes:1. H: High fan speed; M: Medium fan speed; L: Low fan speed.2. The data are test under standard external static pressure. 3. Cooling conditions: entering water 7°C, temperature rise 5°C, entering air temperature 27°C DB/19°C WB. Heating conditions: entering water 50°C, entering air temperature 20°C DB, the same water flow as the cooling conditions.4. Noise is tested in a semi-anechoic test room.

    Fan

    Coil

    Uni

    ts

    Fan

    Coil

    Uni

    ts

    Power supplyAir flow (H/M/L)

    Standard external static pressureCooling

    Heating

    Power input

    Auxiliary electric heater (AEH)Sound pressure levelFan motor

    Fan

    Coil

    Net dimensions (W×H×D)Packing size (W×H×D)Net weight (non-AEH/with-AEH)Gross weight (non-AEH/with-AEH)Water inlet/outlet pipeDrain pipe

    Capacity (H/M/L)Water flow rateWater pressure dropCapacity (H/M/L)Water pressure drop12Pa (H/M/L)30Pa (H/M/L)

    12Pa (H/M/L)30Pa (H/M/L)TypeQuantityTypeQuantityRowMax. working pressureDiameter

    V/Ph/Hzm3/hCFMPakWl/hkPakWkPaWWW

    dB(A)dB(A)

    MPammmmmmkgkg

    Inchmm

    340/255/170200/150/100

    2/1.74/1.52344

    53.2/2.75/2.37

    4.231/25/2245/36/32

    55036/34/2941/37/31

    1

    741×241×522790×260×550

    13.9/15.416.2/17.7

    510/385/255300/225/150

    2.7/2.31/2.03464 11

    4.3/3.74/3.239.5

    50/40/3560/48/42

    65038/33/2941/37/32

    2

    841×241×522890×260×550

    16.5/1819/20.5

    220-240/1/50680/510/340400/300/200

    G12 models: 12; G30 models: 303.6/3.11/2.66

    619 19

    5.4/4.64/4.0515.5

    60/48/4267/54/47

    110038/35/3142/39/33

    Low noise 3-speed fan motor1

    Centrifugal, forward-curved blades22

    1.6Φ9.52

    941×241×522990×260×550

    19.2/20.721.6/23.1

    RC3/4R3/4

    850/640/425500/375/250

    4.4/3.74/3.25757 22

    6.8/5.78/5.0718.3

    80/64/5689/71/62

    110039/36/3245/41/34

    2

    941×241×522990×260×550

    19.2/20.721.6/23.1

    1020/765/510600/450/300

    5.5/4.58/4.09946 14

    8.1/6.77/5.9211.8

    97/78/68110/88/77

    160040/36/3346/41/35

    2

    1161×241×5221210×260×550

    22/2425/27

    MKT2-200G12MKT2-200G30

    MKT2-200EG30

    MKT2-300G12MKT2-300G30

    MKT2-300EG30

    MKT2-400G12MKT2-400G30

    MKT2-400EG30

    MKT2-500G12MKT2-500G30

    MKT2-500EG30

    MKT2-600G12MKT2-600G30

    MKT2-600EG30Model

    Non-AEH

    With-AEH

    Power supplyAir flow (H/M/L)

    Standard external static pressureCooling

    Heating

    Power input

    Auxiliary electric heater (AEH)Sound pressure levelFan motor

    Fan

    Coil

    Net dimensions (W×H×D)Packing size (W×H×D)Net weight (non-AEH/with-AEH)Gross weight (non-AEH/with-AEH)Water inlet/outlet pipeDrain pipe

    Capacity (H/M/L)Water flow rateWater pressure dropCapacity (H/M/L)Water pressure drop12Pa (H/M/L)30Pa (H/M/L)

    12Pa (H/M/L)30Pa (H/M/L)TypeQuantityTypeQuantityRowMax. working pressureDiameter

    V/Ph/Hzm3/hCFMPakWl/hkPakWkPaWWW

    dB(A)dB(A)

    MPammmmmmkgkg

    Inchmm

    MKT2-800G12MKT2-800G30

    MKT2-800EG30

    MKT2-1000G12MKT2-1000G30

    MKT2-1000EG30

    MKT2-1200G12MKT2-1200G30

    MKT2-1200EG30

    MKT2-1400G12MKT2-1400G30

    MKT2-1400EG30Model

    1360/1020/680800/600/400

    7.5/6.33/5.681290

    1411/9.48/8.25

    12.5140/112/98130/104/91

    220042/37/3346/41/36

    1461×241×5221510×260×550

    30.9/33.434.5/37

    1700/1275/8501000/750/500

    8.9/7.61/6.411531

    2213.5/11.72/10.03

    19172/138/120171/137/120

    220044/39/3447/43/37

    1566×241×5221615×260×550

    33.4/36.437/40

    2040/1530/10201200/900/600

    10.8/9.13/7.931858

    3916.5/14.05/12.24

    32.6205/164/144212/170/148

    320046/40/3548/44/38

    1856×241×5221905×260×550

    38.5/4242/45.5

    2380/1785/11901400/1050/700

    12.3/10.46/9.272116

    4619.5/16.85/14.63

    40.1216/173/151249/200/174

    320048/42/3749/44/39

    2022×241×5222070×260×550

    42.1/46.147.5/51.5

    220-240/1/50

    G12 models: 12; G30 models: 30

    Low noise 3-speed fan motor2

    Centrifugal, forward-curved blades42

    1.6Φ9.52

    RC3/4R3/4

    Non-AEH

    With-AEH

  • 49 50

    4-Row Duct A4 Type Duct

    Model

    Power supply

    Air flow (H/M/L)

    Standard external static pressure

    Cooling

    Heating

    Power input (H/M/L)

    Sound pressure level

    Fan motor

    Fan

    Coil

    Net dimensions (W×H×D)

    Packing size (W×H×D)

    Net weight

    Gross weight

    Water inlet/outlet pipe

    Drain pipe

    Capacity (H/M/L)

    Water flow rate

    Water pressure drop

    Capacity (H/M/L)

    Water pressure drop

    Type

    Quantity

    Type

    Quantity

    Row

    Max. working pressure

    Diameter

    V/Ph/Hz

    m3/h

    CFM

    Pa

    kW

    l/h

    kPa

    kW

    kPa

    W

    dB(A)

    MPa

    mm

    mm

    mm

    kg

    kg

    Inch

    mm

    MKT4-200G30

    340/255/170

    200/150/100

    2.5/2.16/1.87

    430

    2.6

    4.1/3.51/3.03

    2.2

    50/40/35

    37/33/27

    1

    1

    741×241×522

    790×260×550

    15.3

    17.6

    MKT4-300G30

    510/385/255

    300/225/150

    3.3/2.85/2.47

    568

    5

    5.8/5.05/4.35

    4.2

    65/52/46

    38/34/28

    1

    2

    841×241×522

    890×260×550

    17.5

    20

    MKT4-400G30

    680/510/340

    400/300/200

    4.4/3.72/3.22

    757

    8.1

    7.1/6.11/5.33

    6.9

    80/64/56

    38/35/29

    1

    2

    941×241×522

    990×260×550

    20.7

    23.1

    MKT4-500G30

    850/640/425

    500/375/250

    4.8/4.18/3.64

    826

    9.8

    8.5/7.04/6.28

    8.1

    98/78/69

    40/35/30

    1

    2

    941×241×522

    990×260×550

    20.7

    23.1

    MKT4-600G30

    1020/765/510

    600/450/300

    6.2/5.38/4.65

    1066

    15.4

    10.5/9.03/7.77

    12.7

    110/88/77

    41/36/31

    1

    2

    1161×241×522

    1210×260×550

    23.5

    26.5

    MKT4-800G30

    1360/1020/680

    800/600/400

    8.8/7.43/6.57

    1514

    12.3

    14.5/12.38/10.88

    10

    155/124/109

    42/37/32

    2

    4

    1461×241×522

    1510×260×550

    32.9

    36.5

    220-240/1/50

    50

    Low noise 3-speed fan motor

    1

    Centrifugal, forward-curved blades

    2

    1.6

    Φ9.52

    1180x340x612

    1310x380x693

    RC3/4

    R3/4

    Model

    Power supply

    Air flow (H/M/L)

    Standard external static pressure

    Cooling

    Heating

    Power input (H/M/L)

    Sound pressure level

    Fan motor

    Fan

    Coil

    Net dimensions (W×H×D)

    Packing size (W×H×D)

    Net weight

    Gross weight

    Water inlet/outlet pipe

    Drain pipe

    Capacity (H/M/L)

    Water flow rate

    Water pressure drop

    Capacity (H/M/L)

    Water pressure drop

    Type

    Quantity

    Type

    Quantity

    Row

    Max. working pressure

    Diameter

    V/Ph/Hz

    m3/h

    CFM

    Pa

    kW

    l/h

    kPa

    kW

    kPa

    W

    dB(A)

    MPa

    mm

    mm

    mm

    kg

    kg

    Inch

    mm

    MKT3-800G50-A4

    1500/1412/1265

    882/831/745

    6.97/6.66/6.28

    1198

    19.0

    9.57/9.09/8.43

    16.9

    151/130/111

    49.7/47.8/45.6

    3

    38.3

    47.2

    MKT4-800G50-A4

    1400/1342/1200

    824/790/706

    7.92/7.56/7.09

    1363

    13.5

    10.42/9.89/9.12

    39.7

    144/124/105

    48.4/47.9/46.6

    4

    39.3

    47

    MKT3-1000G50-A4

    1700/1664/1554

    1000/980/915

    7.77/7.58/7.33

    1336

    24.5

    10.61/10.25/9.82

    21.1

    174/147/130

    50.1/48/45.8

    3

    39.8

    48.6

    MKT4-1000G50-A4

    1650/1527/1405

    970/900/827

    8.15/7.93/7.54

    1402

    21.4

    11.25/10.72/10.06

    23.3

    176/146/128

    49.5/48.1/47.3

    4

    40.8

    49.6

    Model

    Power supply

    Air flow (H/M/L)

    Standard external static pressure

    Cooling

    Heating

    Power input (H/M/L)

    Sound pressure level

    Fan motor

    Fan

    Coil

    Net dimensions (W×H×D)

    Packing size (W×H×D)

    Net weight

    Gross weight

    Water inlet/outlet pipe

    Drain pipe

    Capacity (H/M/L)

    Water flow rate

    Water pressure drop

    Capacity (H/M/L)

    Water pressure drop

    Type

    Quantity

    Type

    Quantity

    Row

    Max. working pressure

    Diameter

    V/Ph/Hz

    m3/h

    CFM

    Pa

    kW

    l/h

    kPa

    kW

    kPa

    W

    dB(A)

    MPa

    mm

    mm

    mm

    kg

    kg

    Inch

    mm

    MKT4-1200G30

    2040/1530/1020

    1200/900/600

    30

    11.8/9.82/8.74

    2030

    21.2

    16.5/14.05/12.23

    17.6

    220/176/154

    45/40/34

    2

    4

    1856×241×522

    1905×260×550

    40.5

    44

    MKT4-1400G30

    2380/1785/1190

    1400/1050/700

    30

    13/11.23/9.83

    2236

    24.7

    17/14.31/12.69

    20.8

    275/220/193

    47/42/36

    2

    4

    2022×241×522

    2070×260×550

    44.1

    49.4

    MKT4-1500

    2550/2100/1300

    1500/1240/760

    30

    13.5/11.5/10.1

    2322

    11.5

    17.5/14.9/13.2

    10

    236/189/165

    48/44/39

    1

    2

    1369×342×612

    1421×381×619

    46

    49.8

    MKT4-2000

    3400/2550/1700

    2000/1500/1000

    30

    18/15.3/13.5

    3096

    26.2

    23.4/19.8/17.5

    24.3

    360/288/252

    50/46/41

    1

    3

    1500×342×612

    1552×381×619

    57

    61

    220-240/1/50

    Low noise 3-speed fan motor

    Centrifugal, forward-curved blades

    4

    1.6

    Φ9.52

    RC3/4

    R3/4

    Notes:1. H: High fan speed; M: Medium fan speed; L: Low fan speed.2. The data are test under standard external static pressure. 3. Cooling conditions: entering water 7°C, temperature rise 5°C, entering air temperature 27°C DB/19°C WB. Heating conditions: entering water 50°C, entering air temperature 20°C DB, the same water flow as the cooling conditions.4. Noise is tested in a semi-anechoic test room.

    Model

    Power supply

    Air flow (H/M/L)

    Standard external static pressure

    Cooling

    Heating

    Power input (H/M/L)

    Sound pressure level

    Fan motor

    Fan

    Coil

    Net dimensions (W×H×D)

    Packing size (W×H×D)

    Net weight

    Gross weight

    Water inlet/outlet pipe

    Drain pipe

    Capacity (H/M/L)

    Water flow rate

    Water pressure drop

    Capacity (H/M/L)

    Water pressure drop

    Type

    Quantity

    Type

    Quantity

    Row

    Max. working pressure

    Diameter

    V/Ph/Hz

    m3/h

    CFM

    Pa

    kW

    l/h

    kPa

    kW

    kPa

    W

    dB(A)

    MPa

    mm

    mm

    mm

    kg

    kg

    Inch

    mm

    MKT4-1200G50-A4

    2040/1851/1666

    1200/1090/981

    10.8/10.17/9.55

    1890

    27.8

    14.3/13.23/12.22

    24.8

    320/284/250

    50.9/50/48.5

    2

    1369x340x612

    1490x380x693

    46.3

    56.4

    MKT4-1400G50-A4

    2420/1851/1666

    1424/1090/981

    12.14/10.17/9.55

    2089

    32.5

    16.08/13.23/12.22

    29.2

    392/284/250

    51.7/50/49.5

    2

    1369x340x612

    1490x380x693

    46.3

    56.4

    MKT4-1600G50-A4

    220-240/1/50

    2430/1917/1742

    1431/1128/1025

    50

    12.19/10.54/9.87

    2096

    33.4

    16.55/13.83/12.9

    30.0

    482/338/296

    52.9/50.7/50

    Low noise 3-speed fan motor

    1

    Centrifugal, forward-curved blades

    2

    4

    1.6

    Φ9.52

    1369x340x612

    1490x380x693

    46.3

    56.4

    RC3/4

    R3/4

    MKT4-1800G50-A4

    3380/2239/1878

    1990/1318/1105

    16.16/12.35/11.01

    2779

    58.3

    21.7/15.79/13.91

    52.3

    538/358/308

    53.6/51.1/50.2

    3

    1500x340x612

    1620x380x693

    54.8

    64.6

    MKT4-2000G50-A4

    3670/2544/2199

    2160/1497/1294

    17.34/13.75/12.44

    2983

    61.5

    23.4/17.92/16.08

    52.9

    583/387/334

    54.4/52.7/51.6

    3

    1500x340x612

    1620x380x693

    54.8

    64.6

    Notes:1. H: High fan speed; M: Medium fan speed; L: Low fan speed.2. The data are test under standard external static pressure. 3. Cooling conditions: entering water 7°C, temperature rise 5°C, entering air temperature 27°C DB/19°C WB. Heating conditions: entering water 50°C, entering air temperature 20°C DB, the same water flow as the cooling conditions.4. Noise is tested in a semi-anechoic test room.

    Fan

    Coil

    Uni

    ts

    Fan

    Coil

    Uni

    ts

    MKT4-1000G30

    1700/1275/850

    1000/750/500

    9.5/8.18/7.06

    1634

    18

    16.3/13.45/12.05

    15.4

    180/144/126

    44/39/33

    2

    4

    1566×241×522

    1615×260×550

    35.4

    39.1

    220-240/1/50

    30

    Low noise 3-speed fan motor

    Centrifugal, forward-curved blades

    4

    1.6

    Φ9.52

    RC3/4

    R3/4

  • 51 52

    High Static Pressure Duct District Cooling Duct

    220-240/1/50

    70

    Low noise 3-speed fan motor

    1

    Centrifugal, forward-curved blades

    1

    1.6

    Φ9.52

    946×400×816

    Left connection: 1075×480×857/1075×480×925 Right connection: 1015×480×857/1015×480×925

    RC3/4

    R3/4

    Power supply

    Air flow (H/M/L)

    Standard external static pressure

    Cooling

    Heating

    Power input (H/M/L)

    Auxiliary electric heater (AEH)

    Sound pressure level

    Fan motor

    Fan

    Coil

    Net dimensions (W×H×D)

    Packing size (non-AEH/with-AEH)(W×H×D)

    Net weight (non-AEH/with-AEH)

    Gross weight (non-AEH/with-AEH)

    Water inlet/outlet pipe

    Drain pipe

    Capacity (H/M/L)

    Water flow rate

    Water pressure drop

    Capacity (H/M/L)

    Water pressure drop

    Type

    Quantity

    Type

    Quantity

    Row

    Max. working pressure

    Diameter

    V/Ph/Hz

    m3/h

    CFM

    Pa

    kW

    l/h

    kPa

    kW

    kPa

    W

    W

    dB(A)

    MPa

    mm

    mm

    mm

    kg

    kg

    Inch

    mm

    1360/1220/1090

    800/720/640

    6.6/6.37/6.12

    1135

    8

    9.7/8.54/7.18

    8.4

    320/300/285

    5000

    49/42/35

    2

    50/53

    55/58

    1700/1530/1380

    1000/900/810

    8.8/8.19/7.57

    1514

    24

    13.2/11.48/9.9

    25

    350/320/300

    5000

    50/43/36

    3

    52/55

    57/60

    2040/1880/1610

    1200/1105/950

    10/9.44/8.53

    1720

    24

    15/12.9/11.25

    23.4

    350/320/290

    5000

    51/44/37

    3

    52/55

    57/60

    2380/2120/1860

    1400/1250/1095

    12/11.47/10.24

    2064

    36

    17.9/15.75/13.6

    34.2

    350/300/285

    5000

    52/45/38

    4

    54/57

    59/62

    Non-AEH MKT3H-800G70 MKT3H-1000G70 MKT3H-1200G70 MKT3H-1400G70

    With-AEH MKT3H-800EG70 MKT3H-1000EG70 MKT3H-1200EG70 MKT3H-1400EG70Model

    Model

    Power supply

    Air flow (H/M/L)

    Standard external static pressure

    Cooling

    Power input (H/M/L)

    Sound pressure level

    Fan motor

    Fan

    Coil

    Net dimensions (W×H×D)

    Packing size (W×H×D)

    Net weight

    Gross weight

    Water inlet/outlet pipe

    Drain pipe

    Capacity (H/M/L)

    Water flow rate

    Water pressure drop

    Type

    Quantity

    Type

    Quantity

    Row

    Max. working pressure

    Diameter

    V/Ph/Hz

    m3/h

    CFM

    Pa

    kW

    l/h

    kPa

    W

    dB(A)

    MPa

    mm

    mm

    mm

    kg

    kg

    Inch

    mm

    MKS4-200G30

    430/380/340

    253/224/200

    30

    2.05/1.742/1.55

    196

    10

    47/38/33

    38/33/27

    1

    741×241×522

    790×260×550

    15.3

    17.6

    MKS4-300G30

    600/540/480

    353/318/282

    30

    2.61/2.21/1.98

    249

    10

    65/52/46

    39/34/28

    2

    841×241×522

    890×260×550

    17.5

    20

    MKS4-400G30

    700/630/520

    412/370/305

    30

    4.03/3.42/3.06

    385

    21

    78/62/55

    39/35/29

    2

    941×241×522

    990×260×550

    20.7

    23.1

    MKS4-500G30

    900/810/720

    530/476/424

    30

    4.57/3.88/3.47

    437

    25

    92/74/64

    41/35/30

    2

    941×241×522

    990×260×550

    20.7

    23.1

    MKS4-600G30

    1160/1040/930

    682/612/547

    30

    6.39/5.43/4.85

    610.6

    53.8

    116/93/81

    42/36/31

    2

    1161×241×522

    1210×260×550

    23.5

    26.5

    MKS4-800G50-A4

    1400/1342/1200

    824/789/705

    50

    6.93/5.89/5.26

    662

    13.3

    144/115/101

    48/47/46

    2

    1180x340x612

    1310x380x693

    39.3

    47

    220-240/1/50

    Low noise 3-speed fan motor

    1

    Centrifugal, forward-curved blades

    4

    1.6

    Φ9.52

    RC3/4

    R3/4

    Non-AEH MKT3H-1600G100 MKT3H-1800G100 MKT3H-2200G100

    With-AEH MKT3H-1600EG100 MKT3H-1800EG100 MKT3H-2200EG100

    Power supply

    Air flow (H/M/L)

    Standard external static pressure

    Cooling

    Heating

    Power input (H/M/L)

    Auxiliary electric heater (AEH)

    Sound pressure level

    Fan motor

    Fan

    Coil

    Net dimensions (W×H×D)

    Packing size (non-AEH/with-AEH)(W×H×D)

    Net weight (non-AEH/with-AEH)

    Gross weight (non-AEH/with-AEH)

    Water inlet/outlet pipe

    Drain pipe

    Capacity (H/M/L)

    Water flow rate

    Water pressure drop

    Capacity (H/M/L)

    Water pressure drop

    Type

    Quantity

    Type

    Quantity

    Row

    Max. working pressure

    Diameter

    V/Ph/Hz

    m3/h

    CFM

    Pa

    kW

    l/h

    kPa

    kW

    kPa

    W

    W

    dB(A)

    MPa

    mm

    mm

    mm

    kg

    kg

    Inch

    mm

    2720/2450/2170

    1600/1440/1280

    14.1/13.03/11.87

    2425

    52

    21.2/18.23/15.69

    51

    550/520/500

    9500

    54/47/40

    220-240/1/50

    3060/2750/2450

    1800/1620/1440

    100

    15.8/14.6/13.46

    2718

    90

    23.8/20.94/17.85

    85

    800/680/620

    9500

    60/53/46

    Low noise 3-speed fan motor

    1

    Centrifugal, forward-curved blades

    2

    3

    1.6

    Φ9.52

    1290×400×809

    Left connection: 1448×460×877/1448×460×950 Right connection: 1383×422×877/1368×460×950

    76/82

    83/89

    RC3/4

    R3/4

    3740/3360/2990

    2200/1980/1760

    19.9/18.58/17.24

    3423

    130

    30/26.7/22.5

    121

    950/860/760

    9500

    61/54/47

    Model

    Notes:1. H: High fan speed; M: Medium fan speed; L: Low fan speed.2. The data are test under standard external static pressure. 3. Cooling conditions: entering water 7°C, temperature rise 5°C, entering air temperature 27°C DB/19°C WB. Heating conditions: entering water 50°C, entering air temperature 20°C DB, the same water flow as the cooling conditions.4. Noise is tested in a semi-anechoic test room.

    Notes:1. H: High fan speed; M: Medium fan speed; L: Low fan speed.2. The data are test under standard external static pressure. 3. Cooling conditions: entering water 5.5°C, temperature rise 9°C, entering air temperature 27°C DB/19°C WB.4. Noise is tested in a semi-anechoic test room.

    Fan

    Coil

    Uni

    ts

    Fan

    Coil

    Uni

    ts

    Model

    Power supply

    Air flow (H/M/L)

    Standard external static pressure

    Cooling

    Power input (H/M/L)

    Sound pressure level

    Fan motor

    Fan

    Coil

    Net dimensions (W×H×D)

    Packing size (W×H×D)

    Net weight

    Gross weight

    Water inlet/outlet pipe

    Drain pipe

    Capacity (H/M/L)

    Water flow rate

    Water pressure drop

    Type

    Quantity

    Type

    Quantity

    Row

    Max. working pressure

    Diameter

    V/Ph/Hz

    m3/h

    CFM

    Pa

    kW

    l/h

    kPa

    W

    dB(A)

    MPa

    mm

    mm

    mm

    kg

    kg

    Inch

    mm

    220-240/1/50

    Low noise 3-speed fan motor

    1

    Centrifugal, forward-curved blades

    4

    1.6

    Φ9.52

    RC3/4

    R3/4

    MKS4-1000G50-A4

    1650/1527/1405

    970/898/826

    50

    7.57/6.43/5.75

    723

    16.3

    176/141/123

    49/48/47

    2

    1180x340x612

    1310x380x693

    40.8

    49.6

    MKS4-1200G50-A4

    2040/1851/1666

    1200/1089/980

    50

    10.11/8.59/7.68

    966

    21

    320/256/224

    51/50/48

    2

    1369x340x612

    1490x380x693

    46.3

    56.4

    MKS4-1400G50-A4

    2420/1850/1657

    1424/1088/975

    50

    11.5/9.7/8.74

    1099

    25.3

    392/314/274

    52/50/49

    2

    1369x340x612

    1490x380x693

    46.3

    56.4

    MKS4-1600G50-A4

    2580/2320/2060

    1518/1365/1212

    50

    11.74/9.97/8.92

    1122

    27.8

    482/386/337

    53/51/50

    2

    1369x340x612

    1490x380x693

    46.3

    56.4

    MKS4-1800G50-A4

    3380/2239/1878

    1988/1317/1105

    50

    14.74/12.52/11.2

    1408

    37.9

    538/430/376

    54/51/50

    3

    1500x340x612

    1620x380x693

    54.8

    64.6

    MKS4-2000G50-A4

    3660/2544/2199

    2153/1496/1295

    50

    16.1/13.68/12.23

    1538

    48.1

    583/466/408

    54/52/51

    3

    1500x340x612

    1620x380x693

    54.8

    64.6

  • 53 54

    4-Pipe Duct4-Pipe Duct

    Model

    Power supply

    Air flow (H/M/L)

    Standard external static pressure

    Cooling

    Heating

    Power input

    Fan motor

    Fan

    Coil

    Net dimensions (W×H×D)

    Packing size (W×H×D)

    Net weight

    Gross weight

    Water inlet/outlet pipe

    Drain pipe

    Capacity (H/M/L)

    Water flow rate

    Water pressure drop

    Capacity (H/M/L)

    Water flow rate

    Water pressure drop

    12Pa (H/M/L)

    30Pa (H/M/L)

    12Pa (H/M/L)

    30Pa (H/M/L)

    Type

    Quantity

    Type

    Quantity

    Row

    Max. working pressure

    Diameter

    V/Ph/Hz

    m3/h

    CFM

    Pa

    kW

    l/h

    kPa

    kW

    l/h

    kPa

    W

    W

    dB(A)

    dB(A)

    MPa

    mm

    mm

    mm

    kg

    kg

    Inch

    mm

    Sound pressure level

    340/255/170

    200/150/100

    2/1.76/1.52

    344

    7.6

    3/2.64/2.22

    258

    6.8

    33/26/23

    49/39/34

    35/32/26

    41/37/31

    1

    741×241×522

    790×260×550

    15.1

    17.4

    510/385/255

    300/225/150

    2.7/2.35/2.13

    464

    14.4

    4/3.48/3

    344

    12.5

    53/38/31

    64/50/42

    36/33/27

    42/38/32

    2

    841×241×522

    890×260×550

    17.5

    20

    680/510/340

    400/300/200

    3.6/3.15/2.76

    619

    8.2

    5.2/4.47/3.9

    447

    23.5

    66/48/42

    75/55/48

    37/34/28

    43/39/33

    2

    941×241×522

    990×260×550

    20.7

    23.1

    850/640/425

    500/375/250

    4.3/3.74/3.32

    740

    9.5

    5.7/5.02/4.33

    490

    24.0

    87/54/44

    96/58/48

    40/36/30

    44/40/34

    2

    941×241×522

    990×260×550

    20.7

    23.1

    1020/765/510

    600/450/300

    5/4.32/3.84

    860

    17.2

    7.2/6.19/5.33

    619

    40.7

    100/67/56

    114/76/64

    42/38/32

    45/41/35

    2

    1161×241×522

    1210×260×550

    23.5

    26.5

    220-240/1/50

    G12 models: 12; G30 models: 30

    Low noise 3-speed fan motor

    1

    Centrifugal, forward-curved blades

    3

    1.6

    Φ9.52

    RC3/4

    R3/4

    MKT3-200FG12MKT3-200FG30

    MKT3-300FG12MKT3-300FG30

    MKT3-400FG12MKT3-400FG30

    MKT3-500FG12MKT3-500FG30

    MKT3-600FG12MKT3-600FG30

    Model

    Power supply

    Air flow (H/M/L)

    Standard external static pressure

    Cooling

    Heating

    Power input

    Fan motor

    Fan

    Coil

    Net dimensions (W×H×D)

    Packing size (W×H×D)

    Net weight

    Gross weight

    Water inlet/outlet pipe

    Drain pipe

    Capacity (H/M/L)

    Water flow rate

    Water pressure drop

    Capacity (H/M/L)

    Water flow rate

    Water pressure drop

    12Pa (H/M/L)

    30Pa (H/M/L)

    12Pa (H/M/L)

    30Pa (H/M/L)

    Type

    Quantity

    Type

    Quantity

    Row

    Max. working pressure

    Diameter

    V/Ph/Hz

    m3/h

    CFM

    Pa

    kW

    l/h

    kPa

    kW

    l/h

    kPa

    W

    W

    dB(A)

    dB(A)

    MPa

    mm

    mm

    mm

    kg

    kg

    Inch

    mm

    Sound pressure level

    220-240/1/50

    G12 models: 12; G30 models: 30

    Low noise 3-speed fan motor

    2

    Centrifugal, forward-curved blades

    4

    3

    1.6

    Φ9.52

    RC3/4

    R3/4

    MKT3-800FG12MKT3-800FG30

    MKT3-1000FG12MKT3-1000FG30

    MKT3-1200FG12MKT3-1200FG30

    MKT3-1400FG12MKT3-1400FG30

    1360/1020/680

    800/600/400

    6.8/5.78/5.11

    1170

    18.8

    9.6/8.45/7.2

    826

    20.7

    145/130/111

    154/132/113

    43/39/33

    46/42/36

    1461×241×522

    1510×260×550

    32.4

    36

    1700/1275/850

    1000/750/500

    7.8/6.74/5.88

    1342

    30.0

    10.8/9.61/8.1

    929

    34.7

    180/104/88

    193/114/97

    45/41/35

    47/43/37

    1566×241×522

    1615×260×550

    34.9

    38.6

    2040/1530/1020

    1200/900/600

    10.2/8.89/7.85

    1754

    40.3

    13.5/12.15/10.26

    1161

    28.6

    210/140/123

    230/157/131

    46/42/36

    48/44/38

    1856×241×522

    1905×260×550

    40

    43.5

    2380/1785/1190

    1400/1050/700

    11.5/9.9/8.86

    1978

    51.9

    15.5/13.48/11.78

    1333

    55.2

    222/201/182

    278/262/228

    48/44/38

    49/45/39

    2022×241×522

    2070×260×550

    43.6

    48.9

    Notes:1. H: High fan speed; M: Medium fan speed; L: Low fan speed.2. The data are test under standard external static pressure. 3. Cooling conditions: entering water 7°C, temperature rise 5°C, entering air temperature 27°C DB/19°C WB. Heating conditions: entering water 70°C, temperature drop 10°C DB, entering air temperature 20°C DB.4. Noise is tested in a semi-anechoic test room.

    Notes:1. H: High fan speed; M: Medium fan speed; L: Low fan speed.2. The data are test under standard external static pressure. 3. Cooling conditions: entering water 7°C, temperature rise 5°C, entering air temperature 27°C DB/19°C WB. Heating conditions: entering water 70°C, temperature drop 10°C DB, entering air temperature 20°C DB.4. Noise is tested in a semi-anechoic test room.

    Fan

    Coil

    Uni

    ts

    Fan

    Coil

    Uni

    ts

  • 55 56

    Stylish front panel blends easily within any interior décor, ideal for use in shops, restaurants or offices with no or narrow false

    ceilings.

    Stylish Panel

    Wall Mounted (C Panel)

    Wall Mounted (S Panel)Built-in 3-Way Electromagnetic Valve

    Auto Swing Louver

    Easy Maintenance

    Multi-directional outlet pipe feature: left\right\rear, to meet the needs of different rooms.

    The Auto Swing Louver function ensures that the air direction corresponds to the mode selected.

    Removable front panel making maintenance convenient.

    Convenient Installation

    C Type Panel S Type Panel

    1

    2

    3

    4

    Step

    Swing

    Model

    Power supply

    Air flow (H/M/L)

    Cooling

    Heating

    Power input (H/M/L)

    Sound pressure level

    Fan motor

    Fan

    Coil

    Net dimensions (W×H×D)

    Packing size (W×H×D)

    Net weight

    Gross weight

    Water inlet/outlet pipe

    Drain pipe

    Capacity (H/M/L)

    Water flow rate

    Water pressure drop

    Capacity (H/M/L)

    Water pressure drop

    Type

    Quantity

    Type

    Quantity

    Row

    Max. working pressure

    Diameter

    V/Ph/Hz

    m3/h

    CFM

    kW

    l/h

    kPa

    kW

    kPa

    W

    dB(A)

    MPa

    mm

    mm

    mm

    kg

    kg

    Inch

    mm

    MKG-250

    425/360/320

    250/210/190

    2.2/1.84/1.65

    378

    12

    3.02/2.6/2.23

    10

    28/22/20

    30/24/20

    915×290×210

    1020×385×300

    12

    16

    MKG-300

    510/430/380

    300/250/220

    2.64/2.24/2.05

    454

    18

    3.69/3.25/2.77

    16.4

    40/32/28

    35/29/24

    915×290×210

    1020×385×300

    12

    16.7

    MKG-400

    220-240/1/50

    680/580/510

    400/340/300

    3.08/2.62/2.27

    530

    22

    4.34/3.86/3.25

    20.8

    44/35/31

    37/31/26

    Low noise 3-speed fan motor

    1

    Tangential fan

    1

    2

    1.6

    Φ7

    915×290×210

    1020×385×300

    12

    17

    G3/4

    ODΦ20

    MKG-500

    850/720/640

    500/420/380

    4.07/3.73/3.24

    700

    26

    5.69/5.12/4.32

    25.1

    50/40/35

    39/33/28

    1070×315×210

    1180×410×300

    15

    19

    MKG-600

    1020/870/770

    600/510/450

    4.45/4.18/3.74

    765

    29

    6.3/5.67/4.73

    27.9

    60/48/42

    40/34/29

    1070×315×210

    1180×410×300

    15

    19

    Model

    Power supply

    Air flow (H/M/L)

    Cooling

    Heating

    Power input (H/M/L)

    Sound pressure level

    Fan motor

    Fan

    Coil

    Net dimensions (W×H×D)

    Packing size (W×H×D)

    Net weight

    Gross weight

    Water inlet/outlet pipe

    Drain pipe

    Capacity (H/M/L)

    Water flow rate

    Water pressure drop

    Capacity (H/M/L)

    Water pressure drop

    Type

    Quantity

    Type

    Quantity

    Row

    Max. working pressure

    Diameter

    V/Ph/Hz

    m3/h

    CFM

    kW

    l/h

    kPa

    kW

    kPa

    W

    dB(A)

    MPa

    mm

    mm

    mm

    kg

    kg

    Inch

    mm

    MKG-250-B

    425/390/350

    250/230/205

    2.63/2.41/2.16

    452

    29.4

    3.36/3.1/2.79

    27.3

    24/19/17

    30/24/20

    915×290×230

    1020×390×315

    13

    16.3

    MKG-300-B

    510/470/390

    300/275/230

    2.97/2.47/2.12

    511

    35.6

    3.91/3.26/2.77

    32.9

    37/29/26

    35/29/24

    915×290×230

    1020×390×315

    13

    16.3

    MKG-400-B

    220-240/1/50

    680/550/460

    400/325/270

    3.28/2.83/2.41

    564

    43.5

    4.37/3.73/3.17

    40.8

    40/32/28

    37/31/26

    Low noise 3-speed fan motor

    1

    Tangential fan

    1

    2

    1.6

    Φ7

    915×290×230

    1020×390×315

    13.3

    16.7

    G3/4

    ODΦ20

    MKG-500-B

    850/745/620

    500/440/365

    4.25/3.85/3.32

    731

    31.8

    5.81/5.17/4.43

    30.2

    50/40/35

    39/33/28

    1072×315×230

    1180×415×315

    15.8

    19.4

    MKG-600-B

    1020/915/780

    600/540/460

    5/4.47/3.97

    860

    42.5

    6.7/6/5.28

    39.7

    66/53/46

    40/34/29

    1072×315×230

    1180×415×315

    15.8

    19.4

    Notes:1. H: High fan speed; M: Medium fan speed; L: Low fan speed.2. Cooling conditions: entering water 7°C, temperature rise 5°C, entering air temperature 27°C DB/19°C WB. Heating conditions: entering water 50°C, entering air temperature 20°C DB, the same water flow as the cooling conditions.3. Noise is tested in a semi-anechoic test room.

    Wall Mounted

    Fan

    Coil

    Uni

    ts

    Fan

    Coil

    Uni

    ts

  • 57 58

    Flexible Installation

    Floor Standing

    Flexible Air Return Type

    Removable Louver

    Cabinet and concealed versions meet various installation requirements.

    Horizontal or vertical installation.

    Air can return from front or bottom of the unit.

    Removable louver for easy maintenance.

    Concealed TypeF3/H3 Series

    Exposed Type (air return from side)

    F4/H4 Series

    Exposed Type (air return from bottom)

    F5/H5 Series

    Power supplyAir flow (H/M/L)

    Cooling

    Heating

    Power input (H/M/L)Sound pressure level

    Fan motor

    Fan

    Coil

    Body (F3 series)

    Body (F4/F5 series)

    Water inlet/outlet pipeDrain pipe

    Capacity (H/M/L)Water flow rateWater pressure dropCapacity (H/M/L)Water pressure drop

    F3 (H/M/L)F4 (H/M/L)F5 (H/M/L)TypeQuantityTypeQuantityRowMax. working pressureDiameterNet dimensions (W×H×D)Packing size (W×H×D)Net weightGross weightNet dimensions (W×H×D)Packing size (W×H×D)Net weightGross weight

    V/Ph/Hzm3/hCFMkWl/hkPakWkPaW

    dB(A)dB(A)dB(A)

    MPammmmmmkgkg

    mmmmkgkg

    Inchmm

    255/215/190150/125/110

    1.15/0.93/0.89198 18.3

    2.54/2.24/1.8816

    27/22/1930/27/2432/29/2630/27/24

    13

    550×545×212639×639×305

    1719

    800×592×225889×683×312

    22.5/22.526.5/26.5

    425/360/320250/210/190

    1.87/1.74/1.59322 10.1

    4.17/3.36/3.138.8

    29/23/2033/30/2835/32/3033/30/28

    13

    550×545×212639×639×305

    1719

    800×592×225889×683×312

    22.5/22.526.5/26.5

    510/430/380300/250/220

    2.53/2.25/1.88435 14.2

    5.64/4.85/4.2313.7

    40/32/2835/32/3037/34/3235/32/30

    22

    750×545×212839×639×305

    2023.5

    1000×592×2251089×683×312

    26/2631/31

    680/580/510400/340/300

    3.27/2.84/2.54562 26.3

    7.22/6.35/5.4924

    46/37/3237/34/3239/36/3437/34/32

    22

    750×545×212839×639×305

    2023.5

    1000×592×2251089×683×312

    26/2631/31

    220-240/1/50

    Low noise 3-speed fan motor1

    Centrifugal, forward-curved blades

    1.6Φ9.52

    G3/4ODΦ16

    MKF3-150MKF4-150MKF5-150

    MKF3-250MKF4-250MKF5-250

    MKF3-300MKF4-300MKF5-300

    MKF3-400MKF4-400MKF5-400

    Model

    Power supplyAir flow (H/M/L)

    Cooling

    Heating

    Power input (H/M/L)Sound pressure level

    Fan motor

    Fan

    Coil

    Body (F3 series)

    Body (F4/F5 series)

    Water inlet/outlet pipeDrain pipe

    Capacity (H/M/L)Water flow rateWater pressure dropCapacity (H/M/L)Water pressure drop

    F3 (H/M/L)F4 (H/M/L)F5 (H/M/L)TypeQuantityTypeQuantityRowMax. working pressureDiameterNet dimensions (W×H×D)Packing size (W×H×D)Net weightGross weightNet dimensions (W×H×D)Packing size (W×H×D)Net weightGross weight

    V/Ph/Hzm3/hCFMkWl/hkPakWkPaW

    dB(A)dB(A)dB(A)

    MPammmmmmkgkg

    mmmmkgkg

    Inchmm

    MKF3-450MKF4-450MKF5-450

    MKF3-500MKF4-500MKF5-500

    MKF3-600MKF4-600MKF5-600

    MKF3-800MKF4-800MKF5-800

    MKF3-900MKF4-900MKF5-900

    Model

    765/650/570450/380/335

    3.97/3.58/3.15683 23.1

    8.85/7.61/6.5522

    39/31/2739/36/3441/38/3639/36/34

    23

    950×545×2121039×639×305

    2529

    1200×592×2251289×683×312

    32.5/32.538/38

    850/720/640500/420/375

    4.85/4.41/3.72834 20

    10.28/9.05/7.7117.4

    49/39/3441/38/3643/40/3841/38/36

    23

    950×545×2121039×639×305

    2529

    1200×592×2251289×683×312

    32.5/3538/40

    220-240/1/501020/870/765600/510/450

    5.64/5.02/4.46970 11.4

    12.24/10.89/9.1810

    63/50/4442/39/3744/41/3942/39/37

    Low noise 3-speed fan motor1

    Centrifugal, forward-curved blades32

    1.6Φ9.52

    1250×545×2121339×639×305

    3236

    1500×592×2251589×683×312

    39/36.645/42.6

    G3/4ODΦ16

    1360/1160/1020800/680/600

    6.52/5.75/4.361121

    2115.35/13.82/11.67

    20.288/70/6244/41/3846/43/4044/41/38

    32

    1250×545×2121339×639×305

    3236

    1500×592×2251589×683×312

    39/3945/45

    1530/1300/1150900/760/675

    7.85/7.19/6.551350 24.3

    18.2/16.38/13.6521.5

    137/109/9646/43/4048/45/4246/43/40

    32

    1250×545×2121339×639×305

    3236

    1500×592×2251589×683×312

    39/3945/45

    Ceiling installationFloor installation

    Notes:1. H: High fan speed; M: Medium fan speed; L: Low fan speed.2. Cooling conditions: entering water 7°C, temperature rise 5°C, entering air temperature 27°C DB/19°C WB. Heating conditions: entering water 50°C, entering air temperature 20°C DB, the same water flow as the cooling conditions.3. Noise is tested in a semi-anechoic test room.

    Floor Standing / Ceiling & Floor

    Fan

    Coil

    Uni

    ts

    Fan

    Coil

    Uni

    ts

  • 59 60

    Ceiling & Floor

    680(

    Hoo

    k-lo

    catio

    n)

    840(

    Body

    )

    950(

    Pane

    l)

    780(Hook-location)

    840(Body)950(Panel)

    4-Pipe 4-way cassetteDimensions (unit: mm)

    Service Space (unit: mm)

    >1000

    >1000

    >10

    00

    >10

    00

    Ceiling

    600mm (ceiling hole)

    Ground

    PanelInletOutlet Outlet880 (ceiling hole)

    >25

    00

    Water pipe jointDrain pipe joint

    Ceiling

    880 (ceiling hole)

    Ground

    PanelInletOutlet Outlet

    4000

    ~25

    00

    Water pipe jointDrain pipe joint

    >33

    0

    Ceiling

    Ground

    InletOutlet

    4-pipe 4-way cassette

    300

    190

    220

    160

    210

    680(

    Hoo

    k-lo

    catio

    n)

    840(

    Body

    )

    950(

    Pane

    l)

    780(Hook-location)840(Body)

    950(Panel)

    Drain sideTubing side

    2-pipe 4-way cassetteDimensions (unit: mm)

    B A C D

    300 190 145 195

    SizeModel

    230 170 135 185

    A B C D

    MKA-950R(A)MKA-1200R(A)MAK-1500R(A)

    MKA-600R(A)MKA-750R(A)

    2-pipe 4-way cassette

    Power supplyAir flow (H/M/L)

    Cooling

    Heating

    Power input (H/M/L)Sound pressure level

    Fan motor

    Fan

    Coil

    Body (H3 series)

    Body (H4/H5 series)

    Water inlet/outlet pipeDrain pipe

    Capacity (H/M/L)Water flow rateWater pressure dropCapacity (H/M/L)Water pressure drop

    H3 (H/M/L)H4 (H/M/L)H5 (H/M/L)TypeQuantityTypeQuantityRowMax. working pressureDiameterNet dimensions (W×H×D)Packing size (W×H×D)Net weightGross weightNet dimensions (W×H×D)Packing size (W×H×D)Net weightGross weight

    V/Ph/Hzm3/hCFMkWl/hkPakWkPaW

    dB(A)dB(A)dB(A)

    MPammmmmmkgkg

    mmmmkgkg

    Inchmm

    255/215/190150/125/110

    1.15/0.93/0.89198 18.3

    1.52/1.22/1.1416

    27/22/1930/27/2432/29/2630/27/24

    13

    550×545×212639×639×305

    1719

    800×592×225889×683×312

    22.5/22.526.5/26.5

    425/360/320250/210/190

    1.87/1.74/1.59322 10.1

    2.53/2.28/2.18.8

    29/23/2033/30/2835/32/3033/30/28

    13

    550×545×212639×639×305

    1719

    800×592×225889×683×312

    22.5/22.527/26.5

    510/430/380300/250/220

    2.53/2.25/1.88435 14.2

    3.49/2.97/2.4413.7

    40/32/2835/32/3037/34/3235/32/30

    22

    750×545×212839×639×305

    2023.5

    1000×592×2251089×683×312

    26/2631/31

    680/580/510400/340/300

    3.27/2.84/2.54562 26.3

    4.58/3.89/3.4424

    46/37/3237/34/3239/36/3437/34/32

    22

    750×545×212839×639×305

    2023.5

    1000×592×2251089×683×312

    26/2631/31

    220-240/1/50

    Low noise 3-speed fan motor1

    Centrifugal, forward-curved blades

    1.6Φ9.52

    G3/4ODΦ16

    MKH3-150MKH4-150MKH5-150

    MKH3-250MKH4-250MKH5-250

    MKH3-300MKH4-300MKH5-300

    MKH3-400MKH4-400MKH5-400

    Model

    Power supplyAir flow (H/M/L)

    Cooling

    Heating

    Power input (H/M/L)Sound pressure level

    Fan motor

    Fan

    Coil

    Body (H3 series)

    Body (H4/H5 series)

    Water inlet/outlet pipeDrain pipe

    Capacity (H/M/L)Water flow rateWater pressure dropCapacity (H/M/L)Water pressure drop

    H3 (H/M/L)H4 (H/M/L)H5 (H/M/L)TypeQuantityTypeQuantityRowMax. working pressureDiameterNet dimensions (W×H×D)Packing size (W×H×D)Net weightGross weightNet dimensions (W×H×D)Packing size (W×H×D)Net weightGross weight

    V/Ph/Hzm3/hCFMkWl/hkPakWkPaW

    dB(A)dB(A)dB(A)

    MPammmmmmkgkg

    mmmmkgkg

    Inchmm

    MKH3-450MKH4-450MKH5-450

    MKH3-500MKH4-500MKH5-500

    MKH3-600MKH4-600MKH5-600

    MKH3-800MKH4-800MKH5-800

    MKH3-900MKH4-900MKH5-900

    Model

    765/650/570450/380/335

    3.97/3.58/3.15683 23.1

    5.64/4.79/4.2322

    39/31/2739/36/3441/38/3639/36/34

    23

    950×545×2121039×639×305

    2529

    1200×592×2251289×683×312

    32.5/32.538/38

    850/720/640500/420/375

    4.85/4.41/3.72834 20

    6.98/6.28/5.2317.4

    49/39/3441/38/3643/40/3841/38/36

    23

    950×545×2121039×639×305

    2529

    1200×592×2251289×683×312

    32.5/32.538/38

    220-240/1/501020/870/765600/510/450

    5.64/5.02/4.46970 11.4

    8.23/6.58/5.5910

    63/50/4442/39/3744/41/3942/39/37

    32

    1250×545×2121339×639×305

    3236

    1500×592×2251589×683×312

    39/3945/45G3/4

    ODΦ16

    1360/1160/1020800/680/600

    6.52/5.75/4.361121

    219.58/8.14/6.32

    20.288/70/6244/41/3846/43/4044/41/38

    32

    1250×545×2121339×639×305

    3236

    1500×592×2251589×683×312

    39/3945/45

    1530/1300/1150900/760/675

    7.85/7.19/6.551350 24.3

    11.69/10.52/9.3521.5

    137/109/9646/43/4048/45/4246/43/40

    32

    1250×545×2121339×639×305

    3236

    1500×592×2251589×683×312

    39/3945/45

    Notes:1. H: High fan speed; M: Medium fan speed; L: Low fan speed.2. Cooling conditions: entering water 7°C, temperature rise 5°C, entering air temperature 27°C DB/19°C WB. Heating conditions: entering water 50°C, entering air temperature 20°C DB, the same water flow as the cooling conditions.3. Noise is tested in a semi-anechoic test room.

    Dimensions4-way cassette

    Fan

    Coil

    Uni

    ts

    Fan

    Coil

    Uni

    ts

    Low noise 3-speed fan motor1

    Centrifugal, forward-curved blades

    Tubing side Drain side

    >33

    0

  • 82608

    61

    61 62

    2-pipe compact 4-way cassetteDimensions (unit: mm)

    Dimensions (unit: mm)

    Dimensions (unit: mm)

    Dimensions (unit: mm)

    4-pipe compact 4-way cassetteDimensions (unit: mm)

    30

    50 630 570 110

    30

    30

    30

    530

    655

    Cei

    ling

    hole

    wid

    th

    Pane

    l wid

    th

    695

    755

    Panel length 1420

    Ceiling hole length 1360

    645 585 125Panel center65

    1015

    75

    90

    210

    84

    60

    CA

    D112

    65

    A 230

    Model MKG-250-BMKG-300-BMKG-400-B

    MKG-500-BMKG-600-BSize

    B

    114 D

    A

    B

    D

    C

    732

    915

    663

    290

    892

    1072

    813

    315

    Model MKG-250MKG-300MKG-400

    MKG-500MKG-600Size

    A

    B

    D

    C

    915

    290

    670

    725

    1070

    315

    815

    88525

    42

    48

    66

    290

    69

    C

    290

    425

    169

    MKC-300R(A)-B MKC-400R(A)-B MKC-600HRN4

    Tubing sideDrain side

    523(

    Hoo

    k-lo

    catio

    n)

    575(

    Body

    )

    647(

    Pane

    l)

    261

    190

    124 2

    13

    261

    H

    190

    124

    213

    110 15

    7

    545(Hook-location)

    575(Body)

    647(Panel)

    Tubing sideDrain side

    523(

    Hoo

    k-lo

    catio

    n)

    575(

    Body

    )

    647(

    Pane

    l)

    545(Hook-location)

    575(Body)

    647(Panel)

    Service Space (unit: mm)

    Ground Ground2-pipe compact 4-way cassette

    Height of the front panel

    Type H (mm)

    4-way cassette 45

    Compact 4-way cassette 50

    4-pipe compact 4-way cassette

    >1000

    >1000

    >10

    00

    >10

    00

    Outlet600 (ceiling hole)

    2300

    ~28

    00

    Water pipe joint Drain pipe joint

    PanelCeiling

    InletOutlet

    >30

    0

    2300

    ~28

    00

    Water pipe joint Drain pipe joint

    Ceiling

    Outlet600 (ceiling hole)

    PanelInletOutlet

    >30

    0

    Compact 4-way cassette

    1-way cassette

    Wall mounted - S panel

    Wall mounted - C panel

    Fan

    Coil

    Uni

    ts

    Fan

    Coil

    Uni

    ts

  • 63 64

    0

    0

    0

    0

    Model Size

    AB

    EDC

    F

    IHG

    J

    LK

    M

    900960

    910885

    1180150195335612342231230340

    13271277

    130812771500160195335612342231230340

    MKT3-800/1000G50-A4

    11351085

    111210851369160195335612342231230340

    MKT4-1200/1400/1500/1600G50-A4

    MKT4-1800/2000G50-A4MKT4-800/1000G50-A4J

    2-pipe duct 4-pipe duct

    F241 241

    water inletwater outlet

    air release valve

    Air release valve

    1010140 140

    180 180

    262

    56

    58

    145

    E B

    HG

    I

    170

    470 52

    2

    241

    241

    180

    180

    258

    258

    545

    545

    126

    345

    203

    291

    212

    203

    345

    592

    118

    178

    225

    178

    74

    291

    111

    178

    128

    128

    AB (Air return)

    K (Air return)

    FDA

    HG

    C

    Terminal box

    4-10×16 hanger slots

    4-10×16 hanger slots

    C

    DE

    AB

    40 19M

    10L

    K

    EDF

    Air filter

    Terminal box

    Terminal box

    C

    11650

    Drain port

    Water inlet RC3/4”

    Water outlet RC3/4”

    Notes:This figure is for reference only, actual product may differ.The dotted line in the figure is the dimension for air return plenum.Units with air return plenum is standard, unis without air return plenum can be customized.

    Air release valve

    Drain port ZG3/4”

    water inlet RC3/4”

    Water outlet RC3/4”

    Air release valve

    Drain port ZG5/4”

    Size

    200CFM

    300CFM

    400CFM

    500CFM

    600CFM

    800CFM

    1000CFM

    1200CFM

    1400CFM

    A

    545

    645

    745

    745

    965

    1265

    1370

    1660

    1826

    B

    485

    585

    685

    685

    905

    1205

    1310

    1600

    1766

    C

    513

    613

    713

    713

    933

    1233

    1338

    1628

    1794

    D

    485

    585

    685

    685

    905

    1205

    1310

    1600

    1766

    E

    741

    841

    941

    941

    1161

    1461

    1566

    1856

    2022

    F

    583

    683

    783

    783

    1003

    1303

    1408

    1698

    1864

    Drain portZG3/4” Cold water

    inlet RC3/4”Hot waterinlet RC3/4”

    Cold wateroutlet RC3/4”

    Hot wateroutlet RC3/4”

    A

    A105 MKF(H)3-150/250

    550

    526

    500

    532

    MKF(H)3-300/400

    750

    726

    700

    732

    MKF(H)3-450/500

    950

    926

    900

    932

    MKF(H)3-600~900

    1250

    1226

    1200

    1232

    Model

    A(mm)

    B(mm)

    C(mm)

    D(mm)

    800

    584

    500

    526

    1000

    784

    700

    726

    1200

    984

    900

    926

    1500

    1284

    1200

    1226

    Model

    A(mm)

    B(mm)

    C(mm)

    D(mm)

    192

    46

    D

    B

    A

    AA

    143

    B

    225

    100 100 46 105

    106192D

    C 150150

    140

    55

    225

    592592

    C

    212 212MKF3 MKH3

    Dimensions (unit: mm) Dimensions (unit:mm)

    Concealed type

    Exposed type

    Dimensions (unit:mm)

    Model

    Size

    AB

    EDC

    F

    IHG

    JK

    816

    946

    400

    778

    767

    306

    219

    88

    37

    338

    512

    MKT3H-800G70MKT3H-1000G70MKT3H-1200G70MKT3H-1400G70

    876

    946

    400

    778

    767

    306

    219

    88

    97

    338

    512

    MKT3H-800EG70MKT3H-1000EG70MKT3H-1200EG70MKT3H-1400EG70

    MKT3H-1600G100MKT3H-1800G100MKT3H-2200G100

    809

    1290

    400

    1118

    765

    900

    249

    88

    39

    320

    995

    MKT3H-1600EG100MKT3H-1800EG100MKT3H-2200EG100

    874

    1290

    400

    1118

    765

    900

    249

    88

    104

    320

    995

    MKF(H)4-150/250MKF(H)5-150/250

    MKF(H)4-300/400MKF(H)5-300/400

    MKF(H)4-450/500MKF(H)5-450/500

    MKF(H)4-600~900MKF(H)5-600~900

    Duct

    High static pressure duct

    Floor standing / Ceiling & Floor

    Fan

    Coil

    Uni

    ts

    Fan

    Coil

    Uni

    ts

  • 65 66

    PC Board Control Kit for FCUWireless Remote ControllersAvailable for all non-PCB FCUs.

    Flexibility installation: can be attached to the unit, mounted on a wall or hung under a ceiling.

    External installation making maintenance more convenient.

    Functions: three fan speeds control, Water pump control, Long-distance ON/OFF control, ALARM function,

    electric heater control.

    Operating status can be displayed by wired controller lamp indicator.

    Centralized control function.

    BMS control function through Modbus protocol.

    Centralized control

    BMS control function through Modbus protocol

    X,Y,E

    X,Y,E

    Centralized controller

    X,Y,E X,Y,E

    P,Q,E

    P,Q,E RS232 Pin hole BMSModbusModbus

    USB port

    P,Q,E P,Q,E

    EPQ R+R-E

    FCUKZ-03 FCUKZ-04

    Model

    Applicable appliance

    Power supply

    Operation range

    Temp. controlling precision

    Net dimension

    Packing size

    Net weight

    Gross weight

    Room temp.

    Inlet water temp.

    W×H×D

    W×H×D

    V-Ph-Hz

    oC

    oC

    oC

    mm

    mm

    kg

    kg

    CE-FCUKZ-03

    2-pipe FCUs

    CE-FCUKZ-04

    4-pipe FCUs

    220~240-1-50/60

    17-30

    3-75

    ±1

    296×66×212

    410×115×262

    1.4

    2.5

    Model Appearance

    R05/BGE

    R51/E

    Function Descriptions Applicable FCUs

    4-way Cassette (standard)

    1-way Cassette (standard)

    Compact 4-way cassette (standard)

    Wall-mounted (standard)

    Wired Controllers

    Centralized Controllers

    LCD display screen

    Mode control

    Fan speeds control

    Time setting / Temp. setting / Swing setting

    Model Appearance

    KJRP-86A1-E

    KJR-18B/E

    Function Descriptions Applicable FCUs

    Duct without electric heater (optional)

    Duct without electric heater (optional)

    KJR-21B/D

    KJR-15B/E

    Duct with electric heater (optional)

    Floor standing / Ceiling & floor (optional)

    LCD display screen

    Mode control

    Fan speeds control

    Timer setting / Temp. setting

    Mechanical thermostat

    Mode control

    Fan speeds control

    Temp. setting

    LCD display screen

    Mode control / Fan speeds control

    Electric heater control

    Temp. setting

    LCD display screen

    Mode control

    Fan speeds control

    Temperature display in oF or oC

    KJR-29B Cassette / Wall-mounted (optional)

    Receiving remote signal

    Mode control

    Fan speeds control

    Temp. setting

    KJR-12B Cassette / wall-mounted (optional)

    Swing function

    Mode control

    Fan speeds control

    Temp. setting

    Control Devices Accessories

    Fan

    Coil

    Uni

    ts

    Fan

    Coil

    Uni

    ts

    Model Appearance

    CCM03

    CCM09

    Function Descriptions Applicable FCUs

    CCM30

    Large LCD display screen

    Max. of 64 FCUs can be controlled by a CCM03

    Mode control / fan speed control

    Time setting / temp. setting / swing setting

    Weekly schedule function

    Basic functions are same as CCM03

    Touch-style keys

    Basic functions are same as CCM03

    All FCUs

    (Compact 4-way cassette FCUs need adding NIM01 module,

    non-PCB FCUs need adding PC board control kit)

  • Centralized wiring

    Valve KitWorking Voltage: AC230±10%, 50/60Hz (24V can be customized).

    Power Consumption: 4W

    Nominal Pressure: 1.6MPa.

    Applied Medium: Cold or hot water, 50% glycol water liquor.

    Medium Temperature: 2 - 15°C (DDSTF-01), -20 - 1°C (DDSTF-04/05).

    Environment Temperature: -5 - 50°C (DDSTF-01), 0 - 50°C (DDSTF-04/05).

    Valve Model

    DDSTF-01

    DDSTF-04

    DDSTF-05

    DN(mm)

    20

    15

    20

    Inner Screw Thead

    3/4”

    1/2”

    3/4”

    Applicable Appliance

    2-pipe cassette/duct/floor standing, 4-pipe duct

    4-pipe cassette (for hot water)

    2-pipe ceiling & floor, 4-pipe cassette (for cold water)

    DDSTF-01

    DDSTF-04

    DDSTF-05

    67 68

    Application of Central Control & BMS Control

    Address setting

    LED

    XYE terminals

    Side port connect to CN20 of FCU PCB

    Network Module

    Achieve centralized control through XYE connection;

    Only available for FCU Cassette Series;

    Address setting should be same as connecting FCU;

    There LEDs display: operation indicator lamp, communication indicator lamp

    and malfunction indicator lamp.

    MD-NIM01Centralized controller

    Centralized controller

    BMS gatewayBMS

    PC in LAN

    BACnetModubusLonWorks

    TCP/IP network

    LAN

    M-interface

    Laptop Access

    Pad Access

    M-net

    PC Access

    PC

    Cloud Servers

    InternetRouter

    Data converter CCM15

    4th generation monitoring system

    Up to 64 units

    Up

    to 1

    6 sy

    stem

    s

    Up to 64 units

    PCB Kit NIM01

    PCB Kit PCB Kit

    Fan

    Coil

    Uni

    ts

    Fan

    Coil

    Uni

    ts

    Centralized controller

    XYE XYE XYE XYE XYE

    Up to 64 FCUs

    CN20 on PCB CN20 on PCB CN20 on PCB CN20 on PCB CN20 on PCB

    Note:DDSTF-** is the model of valve. The valve kit includes valve, actuator and conneting pipe. For different model of units, the models of valve kit are different.

  • 69 70

    Select by entering air and water conditions as well as fan speed.

    Easy to operate interface and visual display.

    Powerful project management function.

    Features

    Main Interface

    Selection Interface

    Report Data Interface

    Selection Software

    Fan

    Coil

    Uni

    ts

    Fan

    Coil

    Uni

    ts

    P35-44P45-56P57-64P65-70