Upload
nguyenngoc
View
274
Download
13
Embed Size (px)
Citation preview
Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
Pneumatic
K
Pneumatic
Basic Valve Functions ...............................................2Features .....................................................................3Common Part Numbers ......................................... 4-5Model Number Index .................................................6Manifold & Subbase Kits ........................................... 7Accessories ............................................................ 8-9Collective Wiring System ................................... 10-12Add-A-Fold Assemblies .......................................... 13Sandwich Flow Controls ......................................... 14
Section K
Sandwich Regulators ......................................... 15-20Technical Information......................................... 21-23Service & Repair Kits .............................................. 24Automotive Connections ......................................... 25Dimensions ........................................................ 26-33Definitions, Weights ................................................ 34
Bold text part numbers are standard.Standard text part numbers may have longer lead times.
“F” SeriesAir Control Valves, Plug-InF3 – .75 Cv, 1/8", 1/4"F5 – 1.55 Cv, 1/4", 3/8"F6 – 3.60 Cv, 3/8", 1/2"F7 – 6.60 Cv, 1/2", 3/4"
pneu
air
e
Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
Pneumatic2
4 2
5 31
#14 #12
Single Remote PilotSingle Pressure At Inlet Port 1:Normal position – Pressure at inlet port 1 connected tooutlet port 2. Outlet port 4 connected to exhaust port 5.Operated position – Maintained air signal at port 14.Pressure at inlet port 1 connected to outlet port 4.Outlet port 2 connected to exhaust port 3.
Double Remote PilotSingle Pressure At Inlet Port 1:Momentary air signal at port 14 last. Pressure at inletport 1 connected to outlet port 4. Outlet port 2 connectedto exhaust port 3.Momentary air signal at port 12 last. Pressure at inletport 1 connected to outlet port 2. Outlet port 4 connectedto exhaust port 5.
4 2
5 31
#14 #12Single SolenoidSingle Pressure At Inlet Port 1:De-energized position – Solenoid operator #14de-energized. Pressure at inlet port 1 connected tooutlet port 2. Outlet port 4 connected to exhaust port 5.Energized position – Solenoid operator #14 energized.Pressure at inlet port 1 connected to outlet port 4.Outlet port 2 connected to exhaust port 3.
Double SolenoidSingle Pressure At Inlet Port 1:Solenoid operator #14 energized last. Pressure at inletport 1 connected to outlet port 4. Outlet port 2 connectedto exhaust port 3.Solenoid operator #12 energized last. Pressure at inletport 1 connected to outlet port 2. Outlet port 4 connectedto exhaust port 5.
Double Solenoid3-PositionWith #12 operator energized – inlet port 1 connected tocylinder port 2, cylinder port 4 connected to exhaust port 5.With #14 operator energized – inlet port 1 connected tocylinder port 4, cylinder port 2 connected to exhaust port 3.Function 5: All Ports BlockedAll ports blocked in the center position.Function 6: Center ExhaustCylinder ports 2 and 4 connected to exhaust ports 3 and 5in center position. Port 1 is blocked.Function 7: Pressure CenterPressure port 1 connected to cylinder ports 2 and 4, andexhaust ports 3 and 5 blocked in center position.
Double Remote Pilot3-PositionWith #12 operator signaled – inlet port 1 connected tocylinder port 2, cylinder port 4 connected to exhaust port 5.With #14 operator signaled – inlet port 1 connected tocylinder port 4, cylinder port 2 connected to exhaust port 3.Function 8: All Ports BlockedAll ports blocked in the center position.Function 9: Center ExhaustCylinder ports 2 and 4 connected to exhaust ports 3 and 5in center position. Port 1 is blocked.Function 0: Pressure CenterPressure port 1 connected to cylinder ports 2 and 4, andexhaust ports 3 and 5 blocked in center position.
Dual Pressure:May be used for dual pressure service with pressure at ports 3 & 5. (Use either external pilot source option “L” or “P” or internalpilot source option “E”.) If pilot source “E” is selected, the high pressure must be at port #3. If pilot source “L” or “P” is selected,the external pilot must be plumbed to either port #14 or #12 respectively. In the 3-Position valve, the effect of dual pressure isextremely important when the valve is in the center position, as the CE and PC functions are reversed. Therefore care shouldbe used when selecting a 3-Position valve.
4 2
5 31
Operator / Function 5
4 2
5 31
Operator / Function 6
4 2
5 31
Operator / Function 7
APB CE
PC
#12#14
#12#14 #12#14
4 2
5 31
#14 #12
4 2
5 31
4 2
5 31
Operator / Function 9Operator / Function 8
4 2
5 31
Operator / Function 0
CE
#12#14#12#14
#12#14
APB
PC
“F” Series Valves2 & 3-Position Valve Functions
Catalog 0600P-7/USA
Basic Valve Functions
Wear Compensation System• Maximum Performance
- Low Friction - Lower Operating Pressures- Fast Response - Less Wear
• Long Cycle Life - Under pressure, radial expansion of the sealoccurs to maintain sealing contact with the valve bore..
• Non-Lube Service - No lubrication required for continuousvalve shifting.
• Bi-Directional Spool Seals - Common spool used for anypressure, including vacuum.
4 2
5 31
#14 #12
pneu
air
e
Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
Pneumatic3
K
“F” Series Valves2 & 3-Position Valve Functions
Catalog 0600P-7/USA
Basic Valve Features
“F3” Valve“F5” Valve
Specifications• F3: .75 Cv• F5: 1.55 Cv• F6: 3.60 Cv• F7: 6.60 Cv
Operating Pressure• Vacuum to 145 PSIG
Ports• NPT Standard• BSPP “G” Option• 1/8 Inch to 3/4 Inch
Cylinder Ports• End and Bottom
Cylinder Ports
Manifolds• Terminal Block Wiring• Collective Wiring• 25-Pin, D-Sub• 19-Pin Round• Allen-Bradley - Dual 12-Pin Round• FlexSAM Serial Bus• Transition Plates
Solenoids• Bi-Polar• Light and Surge
Suppression Standard• Less than 1.8W• 12VDC to 240VAC
Certification / Approval• Approved to be CE Marked• NEMA 4• IP65 (25-Pin, D-Sub)• CSA/NRTL-C
“F6” Valve“F7” Valve
14
1
4
2
3
12
BP BP
1
1412
COM
BP
1
BP
14 12
1 24
5 3
1 245
BP
11
3
14
12
F3 Double Solenoid 3-Position Manifold Mounted
Pressure Exhaust
F5 Double Solenoid Subbase Mounted
F6 Single Solenoid Manifold Mountedpneu
air
e
Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
Pneumatic4
“F” Series Valves4-Way, 2 & 3-Position Part Numbers
Catalog 0600P-7/USA
Common Part Numbers
F6
F7
F6
F7
F3 F3
F5F5
F3
F5
Single Solenoid2-Position
F31VXBG019A 24VDC.75 Cv
F31VXBG023A 120VAC
F51VXBG019A 24VDC1.55 Cv
F51VXBG023A 120VAC
F61VXBG019A 24VDC3.60 Cv
F61VXBG023A 120VAC
F71VXBG019A 24VDC6.60 Cv
F71VXBG023A 120VAC
NLMOR, LED-Surge Suppression, Internal Pilot,Valve Less Base
F32VXBG019A 24VDC.75 Cv
F32VXBG023A 120VAC
F52VXBG019A 24VDC1.55 Cv
F52VXBG023A 120VAC
F62VXBG019A 24VDC3.60 Cv
F62VXBG023A 120VAC
F72VXBG019A 24VDC6.60 Cv
F72VXBG023A 120VAC
NLMOR, LED-Surge Suppression, Internal Pilot,Valve Less Base
Double Solenoid3-Position APB3-Position CE
Double Solenoid2-Position
4 2
5 31
#14 #12
4 2
5 31
#14 #12
4 2
5 31
CE
#12#14
4 2
5 31
APB
#12#14
F6
F7
APB CE
F35VXBG019A 24VDC .55 CvF36VXBG019A 24VDC
.60 CvF35VXBG023A 120VAC F36VXBG023A 120VAC
F55VXBG019A 24VDC1.35 Cv
F56VXBG019A 24VDC1.50 Cv
F55VXBG023A 120VAC F56VXBG023A 120VAC
F65VXBG019A 24VDC3.10 Cv
F66VXBG019A 24VDC3.70 Cv
F65VXBG023A 120VAC F66VXBG023A 120VAC
F75VXBG019A 24VDC6.30 Cv
F76VXBG019A 24VDC6.40 Cv
F75VXBG023A 120VAC F76VXBG023A 120VAC
NLMOR, LED-Surge Suppression, Internal Pilot, Valve Less Base
pneu
air
e
Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
Pneumatic5
K
“F” Series ValvesKits & Accessories
Catalog 0600P-7/USA
Common Part Numbers
F7
F6F3
F5
F7
F6
F7
F6
F5
F3
Manifolds Kits End Plate Kits Subbases Kits
End Port Cyl. End and Cyl. 1, 3, 5 Side AllPorts Bottom Port Ports Ports Ports Ports
PS341151CBP 1/8" PS341161CBP 1/8"PS343100CP 3/8"
PS341111CP 1/8"
PS341152CBP 1/4" PS341162CBP 1/4" PS341112CP 1/4"
—— — PS351163CBP 1/4"PS353100BP 1/2"
PS351113CP 1/4"
—— — PS351165CBP 3/8" PS351115CP 3/8"
PS361155CP 3/8" PS361165CP 3/8"PS363100P 3/4"
PS361115CP 3/8"
PS361157CP 1/2" PS361167CP 1/2" PS361117CP 1/2"
PS371157CP 1/2" PS371167CP 1/2"PS373100P 1"
PS371117CP 1/2"
PS371159CP 3/4" PS371169CP 3/4" PS371119CP 3/4"
All ports are standard NPT. Individual Terminal Block is standard.
Manifold / End Plate / Subbase Kits
F3
F5
Sandwich Flow Control Kits
PS3435P PS3635P
PS3535P PS3735P
Sandwich Regulator Kits
CommonPressureRegulator
DualPressureRegulator
PS3438166P PS3638166P
PS3538166P PS3738166P
125 PSIG with 3/4" Gauge 125 PSIG with 1-1/2" Gauge
F7
F6F3
F5
PS3438266P PS3638266P
PS3538266P PS3738266P
125 PSIG with 3/4" Gauge 125 PSIG with 1-1/2" Gauge
pneu
air
e
Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
Pneumatic6
“F” Series ValveBasic Operator / Mounting/ Pilot Source / Overrides / Enclosures / Voltage & Wiring EngineeringSeries Function Port Size Exhaust Lights Lead Length Frequency Options Options Level
F3 1 51 B G C 23 --- – ABasic Series
F3F5F6F7
Voltage & FrequencyAC
DC Light &60Hz 50Hz Surge Sup
12† 24 24 LED & Sup
15† 12 LED & Sup
19 24 LED & Sup
23 120 115 LED & Sup
83* 120 115 Neon & Sup
87†‡ 240 230 Neon & Sup
XX Remote Pilot
EngineeringLevel
A Current
BOLD OPTIONS ARE STANDARD
Operator / Function
1 Single Solenoid, 2-Position -Air Return
2 Double Solenoid, 2-Position3 Single Remote Pilot, 2-Position -
Air Return4 Double Remote Pilot, 2-Position5 Double Solenoid,
3-Position - APB6 Double Solenoid,
3-Position - CE7 Double Solenoid, 3-Position - PC8 Double Remote Pilot,
3-Position - APB9 Double Remote Pilot,
3-Position - CE0 Double Remote Pilot,
3-Position - PCE Single Solenoid, 2-Position -
Air Return / Spring AssistF Single Remote Pilot, 2-Position -
Air Return / Spring AssistN* Double Solenoid, Dual 3/2
NC / NCP* Double Solenoid, Dual 3/2
NO / NOQ* Double Solenoid, Dual 3/2
NC / NO* Available with F3 Valve, Pilot Source /
Exhaust Option “B” Only.
Mounting Base Style / Port Size
Pilot Source /Exhaust
0 None, RemotePilot Valve
B Internal -Port #1 / Vented
L External - Pilot#14 / Vented
P External - Pilot#12 / Vented
Overrides / Lights
0 None, Remote Pilot ValveG Flush, Non-Locking / LightedH* Flush, Locking / LightedJ*† Extended, Non-Locking / LightedK† Extended, Locking / LightedL Heavy Duty - Non-Locking /
Lighted (F5 Only)
* N/A with F6 / F7† N/A with voltage
codes 12, 15 and 87.
Options
Blank None000 No Sandwich Options with
Wiring Options ‘C’, F’, G’001 Sandwich Flow Control166 Common Port Regulator,
0-125 PSIG w/Gauge206 Single Port Regulator -
Port #2, 125 PSIG w/Gauge260 Single Port Regulator -
Port #4, 125 PSIG w/Gauge266 Dual Port Regulator -
Port #2 & #4, 125 PSIGw/Gauge
466 Sandwich Flow Control &Common Port Regulator,0-125 PSIG w/Gauge
For other regulator options, use lastthree digits from the “SandwichRegulator Ordering Information”.
“F” Series Valves4-Way, 2 & 3-Position Valves
Catalog 0600P-7/USA
Model Number Index
Wiring Options
Blank NoneC* ChryslerF* FordG* General Motors
* Digit Required withEnclosure 7, 8 & 9
* For use with Triac Switch. The typical powerbleed from a Triac Switch may keep the solenoidand indicator lamp energized even after thesolenoid has been de-energized. The Triacoption for 120 / 60 is likely to de-energize thesolenoid and lamp. The neon lamp is usedbecause it requires a higher voltage to maintainillumination over the LED.
† Not available with Override / Light option“J” & “K”.
‡ Not available with Enclosures “J” & “M”.
F311 Subbase: 1/8 NPT Side Ports12 Subbase: 1/4 NPT Side Ports14* Subbase: 1/4 BSPP Side Ports22 Subbase: 1/4 NPT Bottom / Side Port51 Manifold: 1/8 NPT End Ports52 Manifold: 1/4 NPT End Ports62 Manifold: 1/4 NPT Bottom / End Port64* Manifold: 1/4 BSPP Bottom / End Port82 Manifold: 1/4 NPT Bottom / End Port -
Auxiliary Inlet & Outlet84* Manifold: 1/4 BSPP Bottom / End Port -
Auxiliary Inlet & OutletVX Valve Less Base
F513 Subbase: 1/4 NPT Side Ports15 Subbase: 3/8 NPT Side Ports16† Subbase: 3/8 BSPP Side Ports23 Subbase: 1/4 NPT Bottom / Side Ports25 Subbase: 3/8 NPT Bottom / Side Port63 Manifold: 1/4 NPT Bottom / End Port65 Manifold: 3/8 NPT Bottom / End Port66† Manifold: 3/8 BSPP Bottom / End Port85 Manifold: 3/8 NPT Bottom / End Port -
Auxiliary Inlet & Outlet86† Manifold: 3/8 BSPP Bottom / End Port -
Auxiliary Inlet & OutletVX Valve Less Base
Enclosures / Lead Length
F615 Subbase: 3/8 NPT Side Ports17 Subbase: 1/2 NPT Side Ports18† Subbase: 1/2 BSPP Side Ports25 Subbase: 3/8 NPT Bottom / Side Port27 Subbase: 1/2 NPT Bottom / Side Port55 Manifold: 3/8 NPT End Port57† Manifold: 1/2 NPT End Port65 Manifold: 3/8 NPT Bottom / End Port67 Manifold: 1/2 NPT Bottom / End Port68 Manifold: 1/2 BSPP Bottom / End PortVX Valve Less Base
F717 Subbase: 1/2 NPT Side Ports19 Subbase: 3/4 NPT Side Ports10† Subbase: 3/4 BSPP Side Port27 Subbase: 1/2 NPT Bottom / Side Port29 Subbase: 3/4 NPT Bottom / Side Port57 Manifold: 1/2 NPT End Port59 Manifold: 3/4 NPT End Port67 Manifold: 1/2 NPT Bottom / End Port69 Manifold: 3/4 NPT Bottom / End Port60† Manifold: 3/4 BSPP Bottom / End PortVX Valve Less Base
* BSPP ISO 228 Specifications.† BSPP ISO 1179 Specifications.
0 None, Remote PilotValve or Valve LessBase
7* 3-Pin Mini Connectorin Base (SingleSolenoid Only)
8 † 4-Pin M12 EuroConnector in Base
9 5-Pin Mini Connectorin Base
A 6" Leads in Base
B 72" Leads in BaseC Individual Terminal
BlockJ‡ Circuit Board, Single
AddressM‡ Circuit Board,
Double AddressT† SAM Generation 3.0
StyleW 144" Leads in Base
* Only Available with Single Solenoids.† Only Available with Voltage Code “19”-24VDC.‡ Only Available with Manifold Kits. Not Available with 240VAC.
pneu
air
e
Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
Pneumatic7
K
F7
Mounting / Base Style 5 6 8#2 & #4 End Port F3, F6, F7 F3, F5, F6, F7 F3, F5#2 & #4 Bottom Port F3, F5, F6, F7 F3, F5#1 Bottom Port F3, F6, F7 F3#12 & #14 Pilot Port F3 F3 F3
Subbase Kits Manifold Kits
“F” Series ValvesManifold & Subbase Kits
Catalog 0600P-7/USA
Ordering Information
Mounting / Base Style 1 2#1, #2, #3, #4, #5 Side Port F3, F5, F6, F7 F3, F5, F6, F7#1, #2, #3, #4, #5 Bottom Port F3, F5, F6, F7#12 & #14 Pilot Port F3, F5, F6, F7 F3, F5, F6, F7
F5
F6
F3 Mounting Base Style Enclosures / Wiring Engineering FactoryBasic Series Port Size Lead Length Options Level Designator
PS3411 52 C — B P
PS3711
Manifold and Subbase Kit Ordering Code
EngineeringLevel
Blank SubbaseB F3, F5
Manifold
Wiring Options
Blank NoneC* ChryslerF* FordG* General Motors
* Digit Required withEnclosure 7, 8 & 9
PS3611
PS3511
Mounting Base Style / Port Size
F311 Subbase: 1/8 NPT Side Ports12 Subbase: 1/4 NPT Side Ports14* Subbase: 1/4 BSPP Side Ports22 Subbase: 1/4 NPT Bottom / Side Port51 Manifold: 1/8 NPT End Ports52 Manifold: 1/4 NPT End Ports62 Manifold: 1/4 NPT Bottom / End Port64* Manifold: 1/4 BSPP Bottom / End Port82 Manifold: 1/4 NPT Bottom / End Port -
Auxiliary Inlet & Outlet84* Manifold: 1/4 NPT Bottom / End Port -
Auxiliary Inlet & Outlet
F513 Subbase: 1/4 NPT Side Ports15 Subbase: 3/8 NPT Side Ports16† Subbase: 3/8 BSPP Side Ports23 Subbase: 1/4 NPT Bottom / Side Ports25 Subbase: 3/8 NPT Bottom / Side Port63 Manifold: 1/4 NPT Bottom / End Port65 Manifold: 3/8 NPT Bottom / End Port66† Manifold: 3/8 BSPP Bottom / End Port85 Manifold: 3/8 NPT Bottom / End Port -
Auxiliary Inlet & Outlet86† Manifold: 3/8 BSPP Bottom / End Port -
Auxiliary Inlet & Outlet
F615 Subbase: 3/8 NPT Side Ports17 Subbase: 1/2 NPT Side Ports18† Subbase: 1/2 BSPP Side Ports25 Subbase: 3/8 NPT Bottom / Side Port27 Subbase: 1/2 NPT Bottom / Side Port55 Manifold: 3/8 NPT End Port57 Manifold: 1/2 NPT End Port65 Manifold: 3/8 NPT Bottom / End Port67 Manifold: 1/2 NPT Bottom / End Port68† Manifold: 1/2 BSPP Bottom / End Port
F717 Subbase: 1/2 NPT Side Ports19 Subbase: 3/4 NPT Side Ports10† Subbase: 3/4 BSPP Side Port27 Subbase: 1/2 NPT Bottom / Side Port29 Subbase: 3/4 NPT Bottom / Side Port57 Manifold: 1/2 NPT End Port59 Manifold: 3/4 NPT End Port67 Manifold: 1/2 NPT Bottom / End Port69 Manifold: 3/4 NPT Bottom / End Port60† Manifold: 3/4 BSPP Bottom / End Port
Enclosures / Lead Length
0 None, Remote PilotValve or Valve LessBase
7* 3-Pin Mini Connectorin Base (SingleSolenoid Only)
8 † 4-Pin M12 EuroConnector in Base
9 5-Pin Mini Connectorin Base
A 6" Leads in Base
B 72" Leads in BaseC Individual Terminal
BlockJ‡ Circuit Board, Single
AddressM‡ Circuit Board,
Double AddressT† SAM Generation 3.0
StyleW 144" Leads in Base
* Only Available with Single Solenoids.† Only Available with Voltage Code “19”-24VDC.‡ Only Available with Manifold Kits. Not Available with 240VAC.
* BSPP ISO 228 Specifications†BSPP ISO 1179 Specifications
pneu
air
e
Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
Pneumatic8
F5
F3
F3
F5
TransitionPlate
F3
F3
“F” Series ValvesEnd Plate, Transition Plate, Blanking Plate
Catalog 0600P-7/USA
Accessories
F6
F7
F7
Blanking PlateSize Kit Number
PS3434P
PS4034P
PS4134P
PS4234P
Kit includes: (1) Blanking Plate, (1) Gasket, and(3) Mounting Bolts.
F6
F5
End Plate
SizePort Kit NumberSize NPT BSPP “G”
3/8" PS343100CP *PS343101CP
1/2" PS353100BP PS353101BP
3/4" PS363100P PS363101P
1" PS373100P PS373101P
Kit includes: (3) Lock Washers, (3) Socket Head Screws,(3) Fat Washers, (1) Gasket, (1) End Plate without GasketTrack, and (1) End Plate with Gasket Track.
* BSPP ISO 228 Specifications.
Transition Plate
SizeKit Number
NPT BSPP “G”
F3 to F5 PS3527000P *PS3527001P
F3 to F6 PS3626000P *PS3626001P
F5 to F6 PS3627000P PS3627001P
F5 to F7 PS3726000P PS3726001P
F6 to F7 PS3727000P PS3727001P
• Allows manifolding of multiple size F Series valves.
• LOOKING AT THE CYLINDER PORTS, the smaller valveis on the LEFT.
• Transition Plate width:F3 / F5 .72" (18mm) F5 / F7 1.93" (49mm)F3 / F6 1.57" (40mm) F6 / F7 2.42" (61,5mm)F5 / F6 2.36" (60mm)
• Kit includes: (1) Standard Left Hand End Plate - smaller,(1) Standard Right Hand End Plate - larger,(1) Transition Plate, bolts, washers and gaskets.
* BSPP ISO 228 Specifications.
F7
F6
F5
(F3 Shown)
pneu
air
e
Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
Pneumatic9
K
F5
F7
F6
F7
F6
F7
F6
14
12
14
12
14
12
2 12
14
4
2 12
14
4
F5F3
F5
F3
Manifold Port Isolation• Main Galley (1, 3, 5)
Size Kit Number Size Kit Number
PS3432P PS3632P
PS3532P PS3732P
Kit includes: (3) Plugs with O-rings.
• Pilot Galley
Select appropriategasket to blockexternal pilot galleyfor special pilotingapplications.
PS353301BP
PS353300BP
PS353302BP
PS3433P(2) Plugsw/O-Rings
“F” Series ValvesPort Isolation, Access Plates
Catalog 0600P-7/USA
Accessories
F5
Remote Pilot Access Plate
SizePort Kit NumberSize NPT BSPP “G”
1/8" PS351500P PS351501P
1/8" PS361500P PS361501P
1/8" PS371500P PS371501P
• Provides access to #12 & #14 valve pilots.
• Required for Single or Double Remote Pilot Valveon a MANIFOLD. (It is included when you order thevalve/manifold combination, not included withvalve only.)
• Not required with subbase mounting.
• Kit includes: Pilot Port Access Plate, Gasket and3 Mounting Studs.
F5
Auxiliary Access Manifold Kit
SizeKit Number
NPT BSPP “G”
PS352800BP PS352801BP
PS352810BP* PS352811BP*Interconnect
• Used in F5 manifold systems to provide auxiliary accessto #1, #3, and #5 ports.
• Top: 1/2" – #1, #3, and #5 port.
• Bottom: 1/2" – #1 port.
• End (12): 1/8" – #12 and #14 port.• Kit includes: Access Manifold, Gasket and all
required hardware.* Interconnect Kit includes Wiring Harness.
• Width: 1.93" (49mm)
AuxiliaryAccess
Manifold
PS3633P(2) Plugsw/O-Rings
Height:F5 .71" (18mm)F6 .85" (22mm)F7 .94" (24mm)
pneu
air
e
Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
Pneumatic10
“F” Series ValvesFeatures
Catalog 0600P-7/USA (Revised 09/15/04)
Collective Wiring System
(F3 Shown)
Collective Wiring ModuleSize Kit Number
25-Pin, D-Sub Module*† SCD251MB
19-Pin Heavy Duty Round*† SCC191MB
Dual 12-Pin Round - DC*† SCC122MB
Dual 12-Pin Round - AC*† SCC122NB
D-Sub Cable, Non-IP, 3 Meters† P8LMH25M3A
* Kit includes: (1) Wiring Module with Circuit Board Connection,(1) Gasket, (4) Tie Rods and (4) Bolts.
†Available with “H” Series, ISO 5599-2, Sizes 1, 2, 3.(See Catalog 0632-5/USA.
Features• Interconnect Manifolds
• 25-Pin, D-Sub – 24 Addresses
• 19-Pin Round – 16 Addresses
• Dual 12-Pin Round – 16 Addresses
• FlexSAM Serial Bus – 32 Addresses
• SAM 3.0 Serial Bus – 4 Addresses
• Manifold Additions for In-Field Conversions,Plug “N” Play
25-Pin, D-Sub Collective Wiringwith FlexSAM System
SCD251MB SCC191MB
25-Pin, D-Sub Collective Wiring 19-Pin Heavy Duty Wiring
Dual 12-Pin Collective Wiringfor AB Panel Connect
Allen-BradleyPanel Connect
SCC122MB(Dual 12-Pin – DC)
orSCC122NB
(Dual 12-Pin – AC)
25-Pin, D-Sub CableNon-IP, 3-Meter .. PBLMH25IP65, 3-Meter ...... SCD253W
SCC122MB(Dual 12-Pin – DC)
orSCC122NB
(Dual 12-Pin – AC)
pneu
air
e
Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
Pneumatic11
K
F5
F3
F7
F6
F5
“F” Series ValvesEnd Plate & Transition Plate Kits
Catalog 0600P-7/USA (Revised 09/22/04)
Collective Wiring System
NPT BSPP
Blank PS3420L00P PS3420L01P
3/8" Top Port PS3420L10P *PS3420L11P
Blank PS3520L00P PS3520L01P
1/2" Top Port PS3520L10P PS3520L11P
Blank PS3620L00P PS3620L01P
3/4" Top Port PS3620L10P PS3620L11P
Blank PS3720L00P PS3720L01P
1" Top Port PS3720L10P PS3720L11P
Kit includes: (1) CW Left Hand Interface Plate (blank orported), (1) Standard Right Hand End Plate, bolts, washers,gaskets.* BSPP ISO 228 Specifications.
GroundScrew
NPT BSPP
F3 to F5 Blank PS3527L00P PS3527L01P
3/8" Top Port PS3527L10P *PS3527L11P
F3 to F6 Blank PS3626L00P PS3626L01P
3/8" Top Port PS3626L10P *PS3626L11P
F5 to F6 Blank PS3627L00P PS3627L01P
1/2" Top Port PS3627L10P PS3627L11P
F5 to F7 Blank PS3726L00P PS3726L01P
1/2" Top Port PS3726L10P PS3726L11P
F6 to F7 Blank PS3727L00P PS3727L01P
3/4" Top Port PS3727L10P PS3727L11P
Kit includes: (1) CW Left Hand Interface Plate (blank orported) - smaller, (1) Transition Plate, (1) Standard RightHand End Plate - bolts, washers, gaskets, (1) CollectiveWiring Jumper Assembly.* BSPP ISO 228 Specifications.
Collective Wiring (CW)End Plate Kit
Collective Wiring Manifold Configuration:• Choose desired number of Valves / Manifolds with Circuit Boards
• Choose CW End Plate or CW Transition Plate Kit– Plug-in and assemble Manifolds and End Plates together.
• Collective Wiring Module SCD251MB or SCC191MB– Plug-in and assemble Collective Wiring Module to
Collective Wiring Left Hand End Plate.
Collective Wiring (CW)Transition Plate Kit
How to Assemble a Collective Wiring (CW) Add-A-Fold
BlankTop Port
F7
F6
F5
(F3 Shown)
CW Left Hand Interface Plate - Blank and Ported
BlankInterface
Top PortInterface
Interface plate includes a machined hole for the addition ofa ground screw. An earth ground is recommended for allvoltages. Follow standard electrical protocol.
F3F5
TransitionPlate
pneu
air
e
Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
Pneumatic12
“F” Series ValvesPin Out Information
Catalog 0600P-7/USA
Collective Wiring System
25-Pin, D-Sub Cable SpecificationsCommon Pin “13” is rated for 3 amps. Common wire ratingmust be greater than total amperage of all solenoids on aAdd-A-Fold assembly.
Example: 12 station manifold, 24 solenoids,24VDC - 24 x .095 amps = 2.28 total amp rating.
IP65 rated with properly assembled IP65 rated cable.
25-Pin, D-Sub Connector (Male)
1
2
3
4
5
6
7
8
9
10
11
12
13
1
3
5
7
9
11
13
15
17
19
21
23
Common
2
4
6
8
10
12
14
16
18
20
22
24
14
15
16
17
18
19
20
21
22
23
24
25
Address Address
PinNumber
PinNumber
19-Pin Round Cable SpecificationsCommon Pin “7” is rated for 8 amps. Cable common wiremust be greater than total amperage of solenoids on Add-A-Fold assembly.Example: 8 station manifold, 16 solenoids,120VAC - 16 x .039 amps = .63 total amp rating.NEMA 4 rated with properly assembled NEMA 4rated cable.Female Cable Assemblies:Refer to www.connector.com
19-Pin Round Brad Harrison
112
11
13
14
1516
17
1819
2
3
48
9
10
576
PinNumber
1112131415 16 171819
Address9
Ground10111213141516
PinNumber
12345678910
Address1234
N/A5
Common678
Technical SpecificationsMaximum Solenoids Energized Simultaneously
DualVoltage 25-Pin 19-Pin 12-Pin FlexSAM SAM 3.0Code D-Sub Round Round
12VDC 15 18 16 N/A N/A N/A24VAC 12 24 16 N/A N/A N/A
24VDC 19 24 16 16 32* 4120VAC 23, 83 24 16 16 N/A N/A
Face View - Male D-Sub, 25-Pin Connector
Brad Harrison #333030P80M050 16.40 ft. (Female to Male Cable)Brad Harrison #333030P80M0100 32.80 ft. (Female to Male Cable)
* The maximum number of addressed solenoids for FlexSAM is 26through the interconnect system. For 28 through 32 addressedsolenoids all bases are “hard-wired” and valves have to be selectedwith the terminal block option.
1 9 8
712102
311
6
54
PinNumber
123456789
101112
AddressNumber
245678L2---
Ground1---3
Connector APin
Number123456789101112
AddressNumber
101213141516L2---
Ground9---11
Connector B
Supply 120 VAC
1 9 8
712102
311
6
54
PinNumber
123456789
101112
AddressNumber
12345678
Ground---
Common---
Connector APin
Number123456789
101112
AddressNumber
910111213141516
Ground---
Common---
Connector B
Supply 10-30 VDC
A
B
Dual 12-Pin Round Allen-Bradley
Face View - Male 19-Pin Connector
Allen Bradley #889N-F12ACNU-2 2 Meter (Female to Male Cable)Allen Bradley #889N-F12ACNU-3 3 Meter (Female to Male Cable)Allen Bradley #889N-F12ACNU-5 5 Meter (Female to Male Cable)Allen Bradley #889N-F12ACNU-10 10 Meter (Female to Male Cable)
AB Panel Connect Patch Cord Assemblies:Patch Cord good for 24VDC & 120VACFor availability & Specs, contact an Allen-Bradley Distributor
25-Pin, D-Sub Cable (Female)
1
2
3
4
5
6
7
8
9
10
11
12
13
Black
Brown
Red
Orange
Yellow
Green
Blue
Purple
Gray
White
Pink
Lt Green
Black / White
14
15
16
17
18
19
20
21
22
23
24
25
Color
Brown / White
Red / White
Orange / White
Green / White
Blue / White
Purple / White
Red / Black
Orange / Black
Yellow / Black
Green / Black
Gray / Black
Pink / Black
ColorPin
NumberPin
Number1
3
5
7
9
11
13
15
17
19
21
23
Common
2
4
6
8
10
12
14
16
18
20
22
24
AddressAddress
1
2
3
4
5
6
7
8
9
10
11
12
13
1
3
5
7
9
11
13
15
17
19
21
23
Common
2
4
6
8
10
12
14
16
18
20
22
24
14
15
16
17
18
19
20
21
22
23
24
25
Address Address
PinNumber
PinNumber
pneu
air
e
Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
Pneumatic13
KStation Station Station1 2 3
#12 End
#14 End
Example: Application requires a 3-station manifoldand requires isolation between station2 & 3 for all three main galleys.
Item Qty. Part No.
001 1 AAF5SN03002 1 F5563BGC23A ................Station 1003 1 F5163BGC23266A ..........Station 2004 1 PS3532P .........................Galley 1,3,5
Isolation Between Station 2 & 3005 1 F5163BGC23166A ..........Station 3
When ordering a Collective Wiring Add-A-Fold, listthe appropriate wiring module after the AA number.
Example: AAF5CN04SCD251MBF5165BGM83A
For detailed information see page 10 & 11.
“F” Series ValvesAdd-A-Fold Assemblies
Catalog 0600P-7/USA (Revised 6/23/04)
Ordering Information
(F5 Shown)
Valve End Plate Port Number of TransitionSeries Type Type Stations Plate
AA F5 S N 03 —ValveSeries
F3F5F6F7
Transition PlateBlank None
A* F3 to F5B* F3 to F6C* F5 to F6D* F5 to F7E* F6 to F7
* Use largest AA##number
End Plate TypeC Collective Wiring -
Blank End PlateD Collective Wiring -
Ported End PlateS Standard
Port TypeG BSPP “G”N NPT
Number ofStations
02•••
32
Model Number
How To Order Add-A-FoldAssemblies1. List Add-A-Fold Assembly call out. This automatically
includes the end plate kit assembly.2. List complete valve/base model number. List left to right,
LOOKING AT THE CYLINDER PORTS on the #12 endof the manifold. The left most station is station 1.(If a blank station is needed, list the blanking plate partnumber and the individual manifold number in the stationspecified.)
25, 26
27, 28
29, 30
31, 32
1
14-end
5 63
12-end
2 4 7IN
DS DS SS DS
1, 2
3, 4
5, 6
7, 8
OUT
Example 1. Single Addressed Valve Manifold with External Input andOutput Module• First output address the #14 end of the
valve closest to the communicatingmodule.
• External output addresses begin fromthe highest address as shown.
• Unused outputs will be leftover for futurevalve manifold section additions.First external input addresses being withthe input module closest to thecommunications module as shown.
Notes: – Outputs alwaysgrouped in sets of four (4)
– SS = Single Solenoid valve– DS = Double Solenoid valve
Example 2: Double Addressed Valve Manifold with Single D-Sub,25-Pin Modules• First output address the #14 end of
the valve closest to thecommunicating module.
Notes: – Outputs alwaysgrouped in sets of four (4)
– SS = Single Solenoid valve– DS = Double Solenoid valve
I/O Addressing Examples
9 1311
10 1412
1
14-end
5 7
8
3
12-end
2 64
DS DS SS SS DS DS DS
pneu
air
e
Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
Pneumatic14
F7F6
Features• Available with 4-Way, 2 or 3-Position valves
on a subbase or manifold.
• Both adjustment screws are located on the12 end of the unit.
• Sandwich Flow Control mounts with its ownstuds, which means the valve usesstandard bolts for mounting.
• Sandwich Flow Control is not to be usedas a shut off device and is not bubble tightwhen needles are fully turned down.
F5F3
A Sandwich Flow Control and Common Port Sandwich Regulator may be sandwiched together on amanifold or subbase. The Sandwich Flow Control MUST be located between the manifold/subbase and theCommon Port Sandwich Regulator.
* Cv calculated as average of all flow paths with adjustmentscrews full open.
12
1
245 3
BP
1
14(F3 Shown)
“F” Series ValvesFeatures
Catalog 0600P-7/USA
Sandwich Flow Controls
5 4 1 2 3 12
1214
14
5 4 1 2 3
Valve Side
Base Side
(F3 Shown)
Part No. PS3435P PS3535P PS3635P PS3735P
Cv* .50 1.10 1.90 3.80
Height .97" 1.30" 1.30" 1.89"(24,6mm) (33,0mm) (33,0mm) (48,0mm)
Weight .4 lbs. .8 lbs. 1.13 lbs. 2.50 lbs.
pneu
air
e
Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
Pneumatic15
K
Features• Modular Sandwich for use with any
“F” Series Valve.
• Manual Knob Adjustment that locks toprevent adjustment change duringoperation.
• Remote Air Pilot Operated for hard-to-reach pressure control.
• Unregulated Pilot Pressure to valve forconsistent valve shifting regardless ofpressure adjustment.
“F” Series ValvesFeatures
Catalog 0600P-7/USA
Sandwich Regulators
(F5 Shown)
Common PortRegulator
Independent DualPort Regulator
Independent SinglePort Regulator
SelectorRegulator
(F3 Shown) (F5 Shown)
(F6 Shown) (F7 Shown)
Remote AirPilot Regulator(F3 Shown)
pneu
air
e
Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
Pneumatic16
Sandwich Regulator Kit Ordering Code
Sandwich Block #4 Port #2 Port FactoryFunction Regulator / Gauge Regulator / Gauge Designator
PS3438 1 6 6 P
Sandwich Block Function
1 Common PressureRegulator
2 Independent PressureRegulator
3 Pressure Select Regulator
#4 Port Regulator / Gauge*
0 Line Pressure By-Pass Plate**
1 1 - 30 PSIG w/o Gauge
2 2 - 60 PSIG w/o Gauge
3 5 - 125 PSIG w/o Gauge4 1 - 30 PSIG w/ 160 PSIG Small Gauge
5 2 - 60 PSIG w/ 160 PSIG Small Gauge
6 5 - 125 PSIG w/ 160 PSIG SmallGauge
7 1 - 30 PSIG w/ Liquid Gauge
8 2 - 60 PSIG w/ Liquid Gauge
9 5 - 125 PSIG w/ Liquid Gauge
A Air Pilot w/o Gauge
D Air Pilot w/ 160 PSIG Small Gauge
G Air Pilot w/ 160 PSIG Liquid Gauge
H Air Pilot w/ 60 PSIG Large Gauge
J Air Pilot w/ 160 PSIG Large Gauge
K 1 - 30 PSIG w/ 30 PSIG Large Gauge
L 2 - 60 PSIG w/ 60 PSIG Large Gauge
M 5 - 125 PSIG w/ 160 PSIG LargeGauge
#2 Port Regulator / Gauge*
0 Line Pressure By-Pass Plate**
1 1 - 30 PSIG w/o Gauge
2 2 - 60 PSIG w/o Gauge
3 5 - 125 PSIG w/o Gauge4 1 - 30 PSIG w/ 160 PSIG Small Gauge
5 2 - 60 PSIG w/ 160 PSIG Small Gauge
6 5 - 125 PSIG w/ 160 PSIG SmallGauge
7 1 - 30 PSIG w/ Liquid Gauge
8 2 - 60 PSIG w/ Liquid Gauge
9 5 - 125 PSIG w/ Liquid Gauge
A Air Pilot w/o Gauge
D Air Pilot w/ 160 PSIG Small Gauge
G Air Pilot w/ 160 PSIG Liquid Gauge
H Air Pilot w/ 60 PSIG Large Gauge
J Air Pilot w/ 160 PSIG Large Gauge
K 1 - 30 PSIG w/ 30 PSIG Large Gauge
L 2 - 60 PSIG w/ 60 PSIG Large Gauge
M 5 - 125 PSIG w/ 160 PSIG LargeGauge
Series
F3 PS3438F5 PS3538
* For Common Pressure Regulator Option, RegulatorGauge callout must be the same number for bothPort #4 and Port #2.(Example 166)
** Pressure Line By-Pass Option can only be usedwith Independent and Selector Regulators (Option 2& 3 in Sandwich Block Function).
Ordering Components Separately
• Manifold or Subbase Kit required.
• Sandwich Regulator Kit configured for Internal Pilotas standard. (For details of pilot locations, see
cutaways on page 18, 19 and 20.)
• Order valve as External Pilot - 12 (Pilot Source ‘P’)or Internal Pilot (Pilot Source ‘B’) with fieldconverted to external pilot with removable plugs.
Example:1 PS351165CP Manifold Base1 PS3538166P Common Port Regulator1 F51VXPG019A F5 Single Solenoid
External Pilot Valve
“F3” Valve“F5” Valve
“F” Series ValvesF3, F5 Ordering Information
Catalog 0600P-7/USA
Sandwich Regulators
Ordering Complete Valve / Regulator / Base
• Single part number includes Valve, Regulator & Base.
• Must specify if the Complete Unit is Internal Pilot orExternal Pilot (99% of applications are Internal Pilot).
Internal Pilot Configuration -Pressure in Base Port 1 feeds regulator configuredfor Internal Pilot which feeds valve configured forExternal Pilot - 12.Example: F5165BGC19166A (Same example as theOrdering Components Separately example).
External Pilot Configuration -An External Pilot pressure in Port 12 or 14 of thebase feeds thru the Sandwich Regulator 12 or 14galley directly to the 12/14 pilot of the valve. ChoosePilot Source ‘P’ for 12 port pilot and ‘L’ for 14 port pilot.
Example: F5165PGC19166AThis configuration takes an External Pilot from the12 port of the base and passes it thru the regulatorto feed the 12 galley of the valve.
How to configure Sandwich Regulator / Valve Combinations(Note Valve / Regulator / Base Diagrams on following pages for pictorial of details described below)
pneu
air
e
Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
Pneumatic17
K
“F” Series ValvesF6, F7 Ordering Information
Catalog 0600P-7/USA
Sandwich Regulators
#4 Port Regulator / Gauge*
0 Line By-Pass Plate**1 1-30 PSIG w/o Gauge2 2-60 PSIG w/o Gauge3 5-125 PSIG w/o Gauge4 1-30 PSIG w/ 30 PSI Large
Gauge5 2-60 PSIG w/ 60 PSI Large
Gauge6 5-125 PSIG w/ 160 PSI Large
Gauge7 1-30 PSIG w/ Liquid Gauge8 2-60 PSIG w/ Liquid Gauge9 5-125 PSIG w/ Liquid GaugeA Air Pilot w/o GaugeC Air Pilot w/ 60 PSIG Large
GaugeD Air Pilot w/ 160 PSIG Large
GaugeG Air Pilot w/ 160 PSIG Liquid
Gauge
Sandwich Block #4 Port #2 Port FactoryFunction Regulator / Gauge Regulator / Gauge Designator
PS3638 1 6 6 P
* For Common Pressure Regulator Option, RegulatorGauge callout must be the same number for bothPort #4 and Port #2.(Example: 166)
** Pressure Line By-Pass Option can only be usedwith Independent and Selector Regulators (Option 2& 3 in Sandwich Block Function).
#2 Port Regulator / Gauge*
0 Line By-Pass Plate**1 1-30 PSIG w/o Gauge2 2-60 PSIG w/o Gauge3 5-125 PSIG w/o Gauge4 1-30 PSIG w/ 30 PSI Large
Gauge5 2-60 PSIG w/ 60 PSI Large
Gauge6 5-125 PSIG w/ 160 PSI Large
Gauge7 1-30 PSIG w/ Liquid Gauge8 2-60 PSIG w/ Liquid Gauge9 5-125 PSIG w/ Liquid GaugeA Air Pilot w/o GaugeC Air Pilot w/ 60 PSIG Large
GaugeD Air Pilot w/ 160 PSIG Large
GaugeG Air Pilot w/ 160 PSIG Liquid
Gauge
Sandwich Block Function
1 Common PressureRegulator
2 Independent PressureRegulator
3 Selector Regulator
Cv Flow Chart*
“F6” Valve“F7” Valve
Sandwich Regulator Kit Ordering Code
Series
F6 PS3638F7 PS3738
F3
F7
F6
F5
Common Pressure 166 Single Pressure 2 - 206 Single Pressure 4 - 260 Dual Pressure 266
1-2 1-4 2-3 4-5 1-2 1-4 2-3 4-5* 1-2 1-4 2-3 4-5* 1-2 1-4 2-3 4-5*
.42 .43 .59 .56 .43 .52 .50 .48 .53 .43 .50 .48 .43 .43 .50 .48
.63 .61 1.26 1.11 .61 1.10 .87 .86 1.19 .59 .87 .86 .61 .59 .87 .86
2.04 1.97 2.92 2.81 2.33 2.64 2.37 2.37 2.64 2.37 2.37 2.37 2.33 2.37 2.37 2.37
3.10 2.74 5.12 4.99 2.74 3.30 3.85 3.98 3.23 2.77 3.85 3.98 2.74 2.77 3.85 3.98
*Regulator Port exhaust through Base Port 3.
Note: All Cv’s calculated with regulator adjusted full open.
pneu
air
e
Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
Pneumatic18
Common Port RegulationProvides adjustable regulated air pressureto the valve’s #1 port which gives the samepressure to both the #2 and #4 port of themanifold or subbase. The regulator isalways on the 14 end of the valve.
“F” Series ValvesCommon Port Regulator
Catalog 0600P-7/USA
Sandwich Regulator
12
1
245 3
BP
1
14
12
1214
Sandwich Regulator has standardconfiguration of Internal Pilot withthe Pilot Plug in the bottom #12Pilot Hole which prevents linepressure from escaping throughthe manifold.
Valve configured for External Pilot.Pilot Plug moved from #12 Pilot Holeto #1 Pilot Hole.Pilot Plug remains in #14 Pilot Hole.
315
14 12
4 2
Common Port Regulator with 4-Way, 2-Position Valve
Common Port Regulator with 4-Way, 3-Position APB Valve
4 2
315
14
Common Port Regulator - Internal PilotF3 Shown
Example: Ordering Components separately.
1 PS341112AP Subbase
1 PS3438166P Common Port Regulator
1 F31VXPG019A F3 - Ext Pilot 12
Example: Ordering Complete Valve/Regulator/Base.
1 F3112BGA19166A Complete Valve Slice
pneu
air
e
Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
Pneumatic19
K
Independent Port RegulationSingle Port RegulationProvides regulated pressure to one of theports and full line pressure to the otherby use of the Line Pressure By-PassPlate. Pressure regulation can occur outof the #2 or #4 port of the valve.
Dual Port RegulationProvides independent regulatedpressure to the #2 and #4 portsof the manifold or subbase.
When using an Independent Port SandwichRegulator, the cylinder outlet ports arereversed. The 12 end energizes the #4 portand the 14 end energizes the #2 port. The3-Position CE and PC functions are alsoreversed. (See schematics on right.)
“F” Series ValvesIndependent Port Regulator
Catalog 0600P-7/USA
Sandwich Regulator
BP
1
BP
12
14
14
1412
CO
M
14 12
4 1 2
5 3
12
Sandwich Regulator has standardconfiguration of Internal Pilot withthe Pilot Plug in the bottom #12and #14 Pilot Hole which preventsline pressure from escaping throughthe manifold.
Valve configured for External Pilot.Pilot Plug moved from #12 Pilot Holeto #1 Pilot Hole.Pilot Plug remains in #14 Pilot Hole.
4 2
14
Independent Dual Port Regulator with 4-Way, 2-Position Valve
315 315
Independent Port Regulator with 4-Way, 3-Position All Ports Blocked Valve
14 12
4 2
315
14 12
4 2
Independent Port Regulator with 4-Way, 3-Position, Inlet to Cylinder Function
! CAUTION:Requires 4-Way, 3-Position, Cylinder to Exhaust Valve
315
14 12
4 2
Independent Port Regulator with 4-Way, 3-Position, Cylinder to Exhaust Function
! CAUTION:Requires 4-Way, 3-Position, Inlet to Cylinder Valve
Independent Port Regulator - Internal PilotF5 Shown
pneu
air
e
Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
Pneumatic20
Selector RegulationSupplies two different pressures to the valve’s #1 and#3 flow paths. Shifting the valve “selects” one or theother of these two pressures to flow out port #2. ASelector Regulator can 1) Provide regulated pressureto one flow path and full line pressure to the other byuse of the Line Pressure By-Pass Plate or 2) Provideregulated pressure to each of the flow paths. (Note:Port #4 is pressurized with air from #1 flow path when14 end is energized. In many applications, port #4 inthe manifold or subbase needs to be plugged.)
Application
• Use one valve station with Selector Regulator andAuxiliary Inlet / Outlet Manifold to feed pressure to#1 galley of next valve station with Auxiliary Inlet /Outlet Manifold and 2-Position valve. (Controlspeed and torque of air motors, tip pressures ofwelding guns.)
• Multiple pressure control of vacuum / blow-offsystem using Selector Regulator on manifold orsubbase.
“F” Series ValvesSelector Regulator
Catalog 0600P-7/USA
Sandwich Regulator
BP
1
12
12
3
12 12
1414
1 245
14
4 2
14
Selector Regulator with 4-Way, 2-Position Valve
315
Selector Regulator - External PilotF3 Shown
pneu
air
e
Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
Pneumatic21
K
“F” Series ValvesSelector Regulator
Catalog 0600P-7/USA
Technical Information
Main Galley Isolator Plug(Included in Auxiliary In / Out Manifolds)
The F6 & F7 is offered with Selector Regulator. Forthe function described, use Bottom / Side PortedManifolds and connect Port #2 of one station toBottom Port #1 of the next station with tube or hoseconnections. The system may be operated left to rightor right to left.
Valve SystemF6
F7
AB
Selector Regulator with4-Way, 2-Position Valve
Selector Regulator with4-Way, 2-Position Valve
14
1
3
5
12
4-Way, 2-Position Valve
2 4
1414 1212
14 5 1 3 12
12
12
14
BP
SP
SP
DPDP
14 5 1 3 12BP
2 4
P1
S3S2
S1
R1 R2
VALVE 1
VALVE 2 VALVE 3
2 4
14 12
14 5 1 3 12
12
12
14
BP
SPSP
DPDP
F3 Solenoid Valve 1S1 S2 S3 Port 4 Port 2Off Off Off Exh P1On Off Off P1 ExhOff On Off Exh R1On On Off R1 ExhOff Off On Exh R2On Off On R2 ExhOff On On Exh ?On On On ? Exh
The chart shows the multiple outputs achievedwith a two selector regulator system. This systemselects three different pressures - P1, R1, R2 -through Valve #1. Energizing Valve 2 & Valve 3simultaneously (designated by “?”) allows R2 to feedR1, which may produce a different output pressurethan P1 feeding R1.
F5
Valve System
Schematic and picture shown are for the F3 Valve.The F5 Valve is opposite, meaning pressure is fedLEFT to RIGHT.
Valve System
Pilot Pressure withSelector RegulatorValves being supplied from selector regulators (Valves2 & 3 below), could have regulated pressure belowthe minimum operating pressures, and as such shouldhave external pilot supplies. This can be accomplished
The Selector Regulator Manifold System requires theuse of Auxiliary Inlet/Outlet manifolds, which onlyfeeds pressure from right to left (F3) or left to right(F5). Selected pressure exits port #2 (A) and feedsport #1 (B) of the adjacent manifold to the left. A MainGalley Isolator Plug must be used to prevent the P1pressure into Valve #3 from accessing Valve #2.
Selector Regulator –All Solenoids De-EnergizedF3 Shown
by allowing the unregulated pilot pressure from thefirst selector regulator (Valve 3 below) to feed thecommon 12 port. This is accomplished by removingthe pilot plug from the bottom of the first selectorregulator (Valve 3 below). Valves 1 & 2 would bespecified for pilot supply “P”. Valve 3 should specifypilot supply “B” and be modified in the field.
pneu
air
e
Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
Pneumatic22
F6 F7
F3
14
1
3
5
12
P1
2 4
14 12
14 5 1 3 12BP1 BP2
14
1
3
5
12
P1
2 4
14 12
14 5 1 3 12BP
Pilot Pressure SourceThe “F” series offers the ability of converting from one pilot supply source to another. If properly ordered fora specific application, no conversion is necessary. There may be instances, however, when the use of thisflexibility becomes necessary.
Valve Piloting Configurations
F5
Model Code Digits Pilot Supply Holes 3 and 6
Operator/ Pilot1 3 5 BP 12 14Function Source
B M M X X1, E, E X X X X
2, 5, 6, 7 L X M M XP X M M X0 M M X X
3 or F E X X X XP X M M X
4, 8, 9, 0 0 X M M X
Key Code: X = Pilot hole must be plugged.Blank = Pilot hole must be left open.
M = Pilot hole molded shut.
Model Code Digits Pilot Supply Holes 3 and 6Operator/ Pilot
1 3 5 BP4 BP2 12 14Function SourceB M M X X
1, E, E X X X X2, 5, 6, 7 L X M M X
P X M M X0 M M X X
3 or F E X X X XP X M M X
4, 8, 9, 0 0 X M M X X
Key Code: X = Pilot hole must be plugged.Blank = Pilot hole must be left open.
M = Pilot hole molded shut.
Remote PilotAccess Plate
14BPInsert O-ringEnd First
5
3
1
12
14 BP4
BP2
Insert O-ringEnd First5 1
312
“F” Series ValvesValve Piloting Configurations
Catalog 0600P-7/USA
Technical Information
pneu
air
e
Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
Pneumatic23
K
“F” Series ValvesTechnical Data
Catalog 0600P-7/USA
Technical Information
F6
F7
F5
F3
Operating PressureMaximum: 145 PSIG (1000 kPa)Minimum:
Operator/ Min. PSIG Min. PSIG
Function Internal Pilot (kPa) (kPa)F3 / F5 F6 / F7
1 Single Solenoid - 2-Pos
2 Double Solenoid - 2-Pos 20 30
3 Single Remote Pilot - 2-Pos(138) (207)
4 Double Remote Pilot - 2-Pos Vacuum Vacuum
5, 6, 7 Double Solenoid - 3-Pos 30 45APB, CE, PC (207) (310)
8, 9, 0 Double Remote Pilot - 3-Pos Vacuum VacuumAPB, CE, PC
E Single Solenoid Pilot - 2-PosAir Return / Spring Assist 35 45
F Single Remote Pilot - 2-Pos (241) (310)Air Return / Spring Assist
External Pilot *
All “F” Series Vacuum Vacuum
* External Pilot Pressure / Remote Pilot Signal -45-145 PSIG (310-1000 kPa).
Flow Rating (Cv)Port MountingSizeSize Style
2-Position 3-Position
1/4" Ports Subbase .75 .60
1/4" Ports Manifold .70 .55
3/8" Ports Subbase 1.45 1.35
3/8" Ports Manifold 1.55 1.45
1/2" Ports Subbase 3.60 3.10
1/2" Ports Manifold 3.60 3.10
3/4" Ports Subbase 6.60 6.30
3/4" Ports Manifold 6.60 6.30
Temperature Rating5°F to 120°F (-15°C to 49°C) ambient.
** With 100 PSIG supply, time required to fill from 0 to 90 PSIG andExhaust from 100 PSIG to 10 PSIG measured from the instant ofenergizing or de-energizing 24VDC solenoid.
Cv tested per ANSI / (NFPA) T3.21.3
Tested per ANSI / (NFPA) T3.21.8
Response Time**Valve Port 0 Cu. In. Chamber ## Cu. In. ChamberSize Size Fill Exhaust Fill Exhaust
Single Solenoid 2-Position - Air Return /Spring Assist
F3 1/4" .027 .030 .146 .235
F5 3/8" .040 .042 .164 .258
F6 1/2" .056 .058 .137 .203
F7 3/4" .091 .095 .185 .252
## F3 (25), F5 (50), F6 (100), F7 (200)
Solenoid InformationVoltage
Power Inrush Holding Dropout ResistanceCode AC DC (W / VA) (mA) (mA) (V) (ohm)
60Hz 50Hz
12 24 24 — 2.3VA 147 97 16 121
15 — — 12 1.9W — 160 9 75
19 — — 24 2.3W — 94 3.9 270
23 120 110 — 3.8VA 44 32 41 2.5
83 120 110 — 3.2VA 38 27 61 2.7
87 240 230 — 1.8VA 12 7 88 16
CSA / NRTL-CF3 - Standard
F5 - Standard
F6 - Standard
F7 - Standard
Data tested with LED and Surge Suppression.
pneu
air
e
Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
Pneumatic24
F5F3 F6 F7
F3
F5
F7F6
F5
F7
F3
F6
F3
F5
F6
F7
Body Service Kits
VoltageVoltageCode
PS3541*42P 12/42 24VAC
PS3541*45P 15/45 12VDC
PS3541*49P 19/49 24VDC
PS3541*53P 23/53/83 120VAC
PS3441*57P 57/87 240VAC
Key Code: B = Flush, Non-LockingC = Flush, LockingD = Extended, Non-LockingE = Extended, Locking
Kit includes: Solenoid with 2 Screws, Solenoid and Adaptor Seals,Grease Packet.
Solenoid Kits
Pilot Plug KitKit Number
Valve Plugs - F3, F5, F6, F7 Qty 20 PS3509P
Sandwich Reg. Plugs - F3, F5 Qty 20 PS3509P
Sandwich Reg. Plugs - F6, F7 Qty 20 PS3609P
Regulator Conversion Kits
“F” Series ValvesService & Repair Information
Catalog 0600P-7/USA
Service & Repair Kits
Regulator KitsKit Number
PS3439P
PS3639P
Regulator Spring Range Kits
30 PSIG PS3450030P P04427
60 PSIG PS3450060P P04426
125 PSIG PS3450125P P04425
Spool assembly with seals, allpiston seals, return & operatoradaptor seals, solenoid seals, valveto base gasket, grease packet.
2-Position3-Position
Kit Includes:APB CE PC
PS3401P PS3402P PS3403P PS3404P
PS3501P PS3502P PS3503P PS3504P
PS3601P PS3602P PS3603P PS3604P
PS3701P PS3702P PS3703P PS3704P
Manifold Hardware KitsKit Number
12 Tie Rods PS3412BP
12 Tie Rods PS3512BP
Bolts-4 sets of 3 PS3612P
F3
F5
F6
F7
Manifold to Manifold Gasket KitsKit Number
Qty. 1 PS3413BP
Qty. 1 PS3513BP
Qty. 1 PS3613P
Qty. 1 PS3713P
F7F6
Flow Control PS3436P PS3536P PS3636P PS3736PQty. 12Regulator PS3440P PS3540P PS3640P PS3740PQty. 12
F5F3
Regulator & Flow ControlMounting Studs
F3
F7
F6
F5
Manual Bonnet Independent Air Pilot IndependentAssembly to Common Bonnet By-Pass
(w/o Spring) Blank Plate Assembly Plate
PS3445PPS3446P
PS3447PPS3448P
PS3548P
PS3645PN/A
PS3647P PS3648P
Flush Pipe Plug Kits*NPT BSPT†
1/8 Inch PS3468P PS3469P1/4 Inch PS3470P PS3471P3/8 Inch PS3570P PS3571P1/2 Inch PS3670P PS3671P3/4 Inch PS3770P PS3771P
* Must be ordered in Qtys. of 10. † For use with BSPP “G” Threads.
Regulator Gauge KitsKit Number
Standard3/4" Face Air
0-160 PSIG PS3451160P
0-30 PSIG PS3553030PLarge*
0-60 PSIG PS3553060P1-1/2" Face Air
0-160 PSIG PS3553160PLiquid*
0-160 PSIG PS3452160P1-1/2" Face* Includes brass pipe fitting extensions
pneu
air
e
Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
Pneumatic25
K
SOLENOIDCOIL
4-PIN MICRO(TOP COVER)
WH
T
BR
N
BLU
E
BLK
14 END
2
SOLENOIDCOIL
4-PIN MICRO(TOP COVER)
WH
T
BR
N
BLU
E
BLK
14 END
1
23
4
5
SOLENOIDCOIL
5-PIN MINI(TOP COVER)
14 END
1
23
4
5
SOLENOIDCOIL
14 END
‘F’ SAE / Ford Wiring
‘G’ GM Wiring
5-Pin Male / Single Solenoid(Encl. Option 9 & Auto Option F)
5-Pin Male / Single Solenoid(Encl. Option 9 & Auto Option G)
4-Pin Male / Single Solenoid(Encl. Option 8 & Auto Option G)
4-Pin Male / Single Solenoid(Encl. Option 8 & Auto Option F)
5-Pin Male / Double Solenoid(Encl. Option 9 & Auto Option G)
5-Pin Male / Double Solenoid(Encl. Option 9 & Auto Option F)
4-Pin Male / Double Solenoid(Encl. Option 8 & Auto Option G)
4-Pin Male / Double Solenoid(Encl. Option 8 & Auto Option F)
1
23
4
5
SOLENOIDCOIL
5-PIN MINI(TOP COVER)
14 END
SOLENOIDCOIL
12 END
1
23
4
5
SOLENOIDCOIL
5-PIN MINI(TOP COVER)
14 END
SOLENOIDCOIL
12 END
SOLENOIDCOIL
4-PIN MICRO(TOP COVER)
WH
T
BR
N
BLU
E
BLK
14 END
SOLENOIDCOIL
12 END
2 3
SOLENOIDCOIL
4-PIN MICRO(TOP COVER)
WH
T
BR
N
BLU
E
BLK
14 END
SOLENOIDCOIL
12 END
5-PIN MINI(TOP COVER)
1
2 3
4
SOLENOIDCOIL
4-PIN MICRO(TOP COVER)
WH
T
BR
N
BLU
E
BLK
14 END
1
23
4
5
SOLENOIDCOIL
5-PIN MINI(TOP COVER)
RE
D
WH
T
GR
EE
N
BLK
‘C’ Chrysler Wiring
5-Pin Male / Single Solenoid(Encl. Option 9 & Auto Option C)
4-Pin Male / Single Solenoid(Encl. Option 8 & Auto Option C)
5-Pin Male / Double Solenoid(Encl. Option 9 & Auto Option C)
4-Pin Male / Double Solenoid(Encl. Option 8 & Auto Option C)
14 END
OR
NG
RE
D
WH
T
GR
EE
N
BLK
OR
NG
RE
D
WH
T
GR
EE
N
BLK
OR
NG
RE
D
WH
T
GR
EE
N
BLK
OR
NG
RE
D
WH
T
GR
EE
N
BLK
OR
NG
WH
T
GR
EE
N
BLK
OR
NG
1
23
4
5
SOLENOIDCOIL
5-PIN MINI(TOP COVER)
RE
D
14 END
SOLENOIDCOIL
12 END
SOLENOIDCOIL
4-PIN MICRO(TOP COVER)
WH
T
BR
N
BLU
E
BLK
14 END
SOLENOIDCOIL
12 END
1
2 3
4
1
2 3
4 1
2 3
4
1
3
4 1 4
GR
N
2
SOLENOIDCOIL
(+) Signal
(-) Common
1
3
3-Pin Male / Single Solenoid(Encl. Option 7, Auto Option C, F & G)
Automotive Connection – Wiring Options
Automotive ConnectionThread Type5-Pin Mini Connector - 7/8 UNF thread
4-Pin Micro Connector - M12 thread
3-Pin Mini Connector - 7/8 UNF Thread
“F” Series ValvesWiring Options
Catalog 0600P-7/USA
Automotive Connections
pneu
air
e
Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
Pneumatic26
D
D1
B (Single Solenoid)
E
A (Double Solenoid2 & 3-Position)
C
C1
B1 (Single Solenoid)
E1
A1 (Double Solenoid2 & 3-Position)
c of
Bas
eL
c of
Bas
eL
c of
Bas
eL
c of
Bas
eL
D2
C2
B2 (Single Solenoid)
E2
A2 (Double Solenoid2 & 3-Position)
D3
C3
B3 (Single Solenoid)
E3
A3 (Double Solenoid2 & 3-Position)
F7
F6
F5
F3
“F” Series ValvesF3, F5, F6, F7 Solenoid Valves
Catalog 0600P-7/USA
Dimensions
Inches (mm)
DimensionsA A1 A2 A3
6.25 7.54 9.02 10.00(159) (192) (229) (254)
B B1 B2 B3
4.48 5.81 7.16 8.13(114) (148) (182) (207)
C C1 C2 C3
1.33 1.67 2.15 2.72(34) (42) (55) (69)
D D1 D2 D3
1.88 2.02 2.59 2.68(48) (51) (66) (68)
E E1 E2 E3
3.04 3.67 4.52 5.00(77) (93) (115) (127)
Single & Double Operatorspneu
air
e
Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
Pneumatic27
K
C
C1
D2
D
D1
C2
B2 (Single Remote)
E2
A2 (Double Remote2 & 3-Position)
D3
C3
B3 (Single Remote)
E3
A3 (Double Remote2 & 3-Position)
E
A (Double Remote2 & 3-Position)
B (Single Remote)
E1
B1 (Single Remote)
A1 (Double Remote2 & 3-Position)
c of
Bas
eL
c of
Bas
eL
c of
Bas
eL
c of
Bas
eL
F7
F6
F5
F3
“F” Series ValvesF3, F5, F6, F7 Remote Pilot Valves
Catalog 0600P-7/USA
Dimensions
Inches (mm)
DimensionsA A1 A2 A3
4.89 4.58 6.46 7.44(124) (116) (164) (189)
B B1 B2 B3
3.90 4.13 5.87 6.85(99) (105) (149) (174)
C C1 C2 C3
1.33 1.67 2.15 2.72(34) (42) (55) (69)
D D1 D2 D3
1.88 1.82 2.41 2.47(48) (46) (61) (63)
E E1 E2 E3
2.44 2.29 3.23 3.72(62) (58) (82) (94)
Single & Double Operatorspneu
air
e
Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
Pneumatic28
5
1
3
E
F
C
G
4 2
1/2 PipeConduit
A
B
H
D
1/4 or 3/8Ports 1, 3 & 5
.26 (6,6)Mtg. Holes (2)
(5) BottomPorts
E
F
G
4 2
14
4 2
12
1/8 Ports12 & 14
Side PortedSubbase
Bottom PortedSubbase
c of
Bas
eL
“F” Series ValvesF3 & F5 Subbase
Catalog 0600P-7/USA
Dimensions
F3
F5Dimensions
A B C D5.83 1.48 2.50 3.86(148) (38) (64) (98)
E F G H3.29 1.57 2.00 .57(84) (40) (51) (14,5)
Inches (mm)
BJ
EF
G G
1/8 Ports12 & 14
1/4 CommonExhaust Port (Optional)
1/2 PipeConduit
C
1/8 or 1/4Ports 1, 3 & 5
14
43-5
2
4
5 1
3
1
5 3
2
12
4
5 13
2
DHTerminalBlockCover
A
EF
A
Side PortedSubbase
Bottom PortedSubbase
.20 (5) Mtg. Holes (2)
(5) BottomPorts
c of
Bas
eL
Dimensions
A B C D4.45 1.28 2.00 3.00(113) (33) (51) (76)
E F G H2.94 1.67 1.63 .79(75) (42) (41) (20)
J.65(17)
Inches (mm)
pneu
air
e
Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
Pneumatic29
K
DC
Side PortedSubbase
B
H
EF
EF
A
G
A
G
Bottom PortedSubbase
.28 (7,1) Mtg. Holes (2)
1/8 Inch Ports 12 & 14
(5) Side Ports
1/2 PipeConduit
(5) BottomPorts
c of
Bas
eL
EF
A
G
B
H
Bottom PortedSubbase
Side PortedSubbase
G
E
D
F
A
C
(5) 1/2 InchSide Ports
(5) 1/2 InchBottom Ports
1/8 Inch Ports 12 & 14
1/2 PipeConduit
.35 (9,0) Mtg. Holes (2)
c of
Bas
eL
F6
F7
“F” Series ValvesF6 & F7 Subbase
Catalog 0600P-7/USA
Dimensions
Dimensions
A B C D7.90 2.96 3.90 4.92(201) (75) (99) (125)
E F G H5.14 2.50 3.24 1.06(131) (64) (82) (27)
Inches (mm)
Dimensions
A B C D6.69 2.33 3.15 4.25(170) (59) (80) (108)
E F G H4.21 2.07 2.56 .71(107) (53) (65) (18)
Inches (mm)
pneu
air
e
Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
Pneumatic30
CH
F + (C x n)G + (C x n)
F1 + (C x n)F2 + (C x n)
C
1 PipeConduit
3/8 Ports1, 3 & 5
1/8 Ports 12& 14 ForExternal Pilot
1/8 or 1/4Ports 2 & 4
5
1
1
4
2
3
4
2
14
12
4
2
14
12
4
2
14
12
1/8 Ports 12& 14 ForExternal Pilot
1/8 or 1/4Ports 2 & 4
4
2
14
12
4
2
14
12
4
2
14
12
D1 Blank Interface PlateD2 Top Port Interface Plate
Interface Plate Mounting Hole Locations
1
4
2
BJ J
n = Number of Stations
Manifold with Optional Collective Wiring System
G1 + (C x n)G2 + (C x n)
n = Number of StationsF1, G1 = Blank Interface Plate
F2, G2 = Top Port Interface Plate
E
E2
A
A1
D
.26 (6.6)Mtg. Holes (2)
.26 (6.6)Mtg. Holes (2)
E1
E3
BottomPortedManifold
c of
Bas
eL
A
1/8 InchPilot Ports
1/2 InchPorts 1, 3 & 5
5 31
D
1 PipeConduit
.26 (6.6)Mtg. Holes (2)
4 2 4 2 4 2 B
H
G + (C x n)
CF + (C x n)
C
n = Number of Stations
4 2 4 2 4 2
G1 + (C x n)G2 + (C x n)
F1 + (C x n)F2 + (C x n)
n = Number of StationsF1, G1 = Blank Interface Plate
F2, G2 = Top Port Interface Plate
Manifold with Optional Collective Wiring System
E1
.27 (6.9)Mtg. Holes (2)
E1
E
E2
BottomPortedManifold
Interface Plate Mounting Hole Locations
c of
Bas
eL
D1 Blank Interface PlateD2 Top Port Interface Plate
A
F3
F5
Inches (mm)
“F” Series ValvesF3 & F5 Manifold
Catalog 0600P-7/USA
Dimensions
DimensionsA B C D
6.50 2.21 1.93 .44(165) (56) (49) (11)
D1 D2 E E1
.41 1.10 7.15 .33(11) (28) (182) (8)
E2 F F1 F2
4.25 .87 .64 .90(108) (22) (16) (23)
G G1 G2 H1.80 2.56 3.26 .42(46) (65) (83) (11)
Inches (mm)
DimensionsA A1 B C
4.12 6.50 2.17 1.40(105) (165) (55) (36)
D D1 D2 E.23 .21 .47 6.07(6) (5) (12) (154)
E1 E2 E3 F.46 4.02 .37 .82(12) (102) (9) (21)
F1 F2 G G1
.62 .80 1.28 2.34(16) (20) (33) (59)
G2 H J2.87 .79 1.62(73) (20) (41)
* For 19-Pin Round ConnectorModule, add 1.08" (27.5mm)to the G1 & G2 dimensions.
* For 19-Pin Round ConnectorModule, add 1.08" (27.5mm)to the G1 & G2 dimensions.
pneu
air
e
Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
Pneumatic31
K
14
1
5 3
12
2
4
2
4
2
4
(3) 3/4 InchPorts
1/8 InchPilot Ports
1-1/4 PipeConduit
AE1
D
EE2
.47 (12)Mtg. Holes (2)
C
G + (C x n)n = Number of Stations
F + (C x n)
BottomPortedManifold
B
H
14
2
AE1
.47 (12)Mtg. Holes (2)
Interface PlateMounting Hole Locations
14
2
2
4
2
4
2
4
C
G1 + (C x n)
F1 + (C x n)
G2 + (C x n)
F2 + (C x n)
n = Number of StationsF1, G1 = Blank Interface Plate
F2, G2 = Top Port Interface Plate
Manifold with Optional Collective Wiring System
c of
Bas
eL
D1 Blank Interface PlateD2 Top Port Interface Plate
14
1
14
2
3
2
45
12
(3) 1 InchPorts
1/8 InchPilot Ports
1-1/4 PipeConduit
A
D
E
E2
C
G + (C x n)n = Number of Stations
F + (C x n)
BottomPortedManifold
B
H
2
4
2
4
2
4
C
2
4
2
4
E1
.47 (12)Mtg. Holes (2)
14
2
A
Interface PlateMounting Hole Locations
E1
.47 (12)Mtg. Holes (2)
G1 + (C x n)G2 + (C x n)
F1 + (C x n)F2 + (C x n)
n = Number of StationsF1, G1 = Blank Interface Plate
F2, G2 = Top Port Interface Plate
Manifold with Optional Collective Wiring System
c of
Bas
eL
D1 Blank Interface PlateD2 Top Port Interface Plate
F6
F7
“F” Series ValvesF6 & F7 Manifold
Catalog 0600P-7/USA
Dimensions
DimensionsA B C D
8.46 3.35 2.20 .59(215) (85) (56) (15)
D1 D2 E E1
.47 .71 9.41 .47(12) (18) (239) (12)
E2 F F1 F2
5.28 1.18 1.06 1.30(134) (30) (27) (33)
G G1* G2* H2.36 3.41 3.88 .55(60) (87) (99) (14)
Inches (mm)
* For 19-Pin RoundConnector Module, add1.08" (27.5mm) to the G1 &G2 dimensions.
DimensionsA B C D
10.43 4.13 2.80 .65(265) (105) (71) (17)
D1 D2 E E1
.47 .94 11.61 .59(12) (24) (295) (15)
E2 F F1 F2
6.26 1.30 1.12 1.59(159) (33) (28) (40)
G G1* G2* H2.60 3.54 4.49 .83(66) (90) (114) (21)
Inches (mm)
* For 19-Pin Round ConnectorModule, add 1.08" (27.5mm)to the G1 & G2 dimensions.
pneu
air
e
Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
Pneumatic32
F3
F5
Regulator
Regulator
2.05(52)
8.13(207)
6.40(163)
11.84(301)
2.09(53)
1.63(41)
2.85(72)
5.45(138)
4.25(108)
Liquid Gauge &Large Air Gauge
Dimensions
c of
Bas
eL
1.71(43)
2.51(64)
7.13(181)
5.45(138)
10.31(262)
1.45(37)
1.36(35)
5.04(128)
3.81(97)
Liquid Gauge &Large Air Gauge
Dimensions
c of
Bas
eL
“F” Series ValvesF3, F5 Sandwich Regulator
Catalog 0600P-7/USA
Dimensions
pneu
air
e
Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
Pneumatic33
K
F6
F7
Regulator
Regulator
“F” Series ValvesF6, F7 Sandwich Regulator
Catalog 0600P-7/USA
Dimensions
8.50(216)
10.56(268)
16.18(411)
6.92(196)
4.20(107)
2.80(71)
2.15(55)
1.07(27)
c of
Bas
eL
Single Port14.65(372)
9.84(250) Common Port
9.10(231)
11.53(293)
17.15(436)
8.37(213)
4.20(107)
2.93(75)
2.50(64)
1.25(32)
c of
Bas
eL
Single Port
15.67(398)
10.67(271 Common Portp
neu
air
e
Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic
Pneumatic34
F6
F7
F3
F5
Table 1Compression Factors and “A” Constants
“A” Constants for VariousInlet Compression Pressure Drop*Pressure Factor 2 PSI 5 PSI 10 PSI(PSIG) ∆∆∆∆∆ P ∆∆∆∆∆ P ∆∆∆∆∆ P10 1.6 .155 .10220 2.3 .129 .083 .06630 3.0 .113 .072 .05540 3.7 .097 .064 .04850 4.4 .091 .059 .04360 5.1 .084 .054 .04070 5.7 .079 .050 .03780 6.4 .075 .048 .03590 7.1 .071 .045 .033
100 7.8 .068 .043 .031110 8.5 .065 .041 .030120 9.2 .062 .039 .029130 9.9 .060 .038 .028140 10.6 .058 .037 .027150 11.2 .056 .036 .026160 11.9 .055 .035 .026170 12.6 .054 .034 .025180 13.3 .052 .033 .024190 14.0 .051 .032 .024200 14.7 .050 .031 .023
Note: Use “A” constant at 5 PSI ∆ P for most applications. On very criticalapplications, use “A” at 2 PSI ∆ P. You will find in many cases, a 10 PSI ∆ P isnot detrimental, and can save money and mounting space.
* Tabulated values are the solution of where T is for68°F and G =1 for Air.
Single 3-Position SandwichSolenoid Solenoid
Manifold Subbase End PlateRegulator
.6 .9 1.1 .7 1.1 .6
1.0 1.3 1.6 .9 1.2 1.2
2.0 2.5 2.6 2.9 3.4 5.8
4.8 5.3 4.8 3.7 5.6 5.8
Weights are in pounds and are approximate.
DefinitionsCE ................... Certification of a product to meet European
Community standards. “F” Series solenoidvalves are approved for CE.
CSA/NRTL-C .. Canadian Standards Association and ULApplicable. (See page 23)
IP65 ................. International classification system forsealing effectiveness for enclosures ofelectrical equipment. IP stands for “IngressProtection” and the two digits XY stand for:X - protection from solid objects and Y -protection from moisture. IP65 is protectionfrom dust and water washdown.
NEMA 4 ........... National standard for enclosure protection.NEMA 4 provides protection against dirt,dust, water hosedown and rain. (Morestringent than IP65)
NLMOR ........... Non-Locking Manual Override. A constantactuation must be maintained for the valveto remain shifted.
LMOR .............. Locking Manual Override. Valve remainsshifted without constant end user overrideactuation.
Surge SuppressionNullifies reverse EMF generated when asolenoid is de-energized. “F” Series VoltageCode 12, 15, 19, 23, 83, and 87 includesurge suppression.
Bi-Polar ........... Solenoids are non-polarity sensitive and canbe reverse wired. All “F” Series solenoidsare non-polarity sensitive.
SCFM .............. Measure of air flow. Standard Cubic Feetper Minute at 68°F and 36% humidityat sea level.
PSIG ................ Pounds per Square Inch measured with agage. (Catalog pressure reflects PSIG)
PSIA ................ Pounds per Square Inch atmospheric.
kPa .................. Kilopascals. International measure ofpressure. 145 PSIG = 1000 kPa
PSIG = 0 PSIA = 14.7 In. of Hg = 29.92 kPa = 0
Cv CalculationsCv ............ Measure of calculating flow of a valve (or other
pneumatic device) that takes into effect thetemperature, pressure, pressure drop, and flow.As a rule of thumb, a Cv of 1.0 is 25 SCFM with a5 PSIG pressure drop.
Cylinder Area Cylinder Compression “A”(Sq. In.) X Stroke X Factor X (Table 1)
Cv =(See Table 2) (In.) (Table 1)
Stroke Time (sec.) x 28.8
Table 2Effective Square-Inch Areas for
Standard-Bore-Size Cylinders
Bore Cylinder Area Bore Cylinder AreaSize (Sq. In.) Size (Sq. In.)
3/4" .44 4" 12.571" .79 41/2" 15.90
11/8" .99 5" 19.6411/4" 1.23 6" 28.2711/2" 1.77 7" 38.4813/4" 2.41 8" 50.272" 3.14 10" 78.54
21/2" 4.91 12" 113.1031/4" 8.30 14" 153.9435/8" 10.32
Product Shipping Weights
“F” Series ValvesPlug-In Subbase Valves
Catalog 0600P-7/USA
Definitions & Weights
1 GT22.48 (P1 – P2) P2
pneu
air
e