Upload
others
View
0
Download
0
Embed Size (px)
Citation preview
PATTERN 1 PATTERN 2PATTERN 3
75MM CONCRETE CAPPING OVER FILL MATERIAL
No. AppdRevision Chk.V Date
DO NOT SCALE
* Refer to Revision 1 for Original Signature
Scale (A1)
Scale (A3)Reduced
Dwg Check
Dsg Verifier
Drawn
Original Design
Date
Approved For Project:
IF IN DOUBT ASK.
Title: Drawing No:
Docu
ment
No.
Rev.
Drawing Plotted:
SH1 MACKAYS TO PEKA PEKA
RP 1012/0.00 TO 1023/5.00Document created for NZTA by M2PP Alliance, Level 2, 17-21 Whitmore St, WELLINGTON
DE
TA
IL D
ES
IGN
(D
ET
)
Construction*
By Chk
EXPRESSWAY
0mm
30
10
20
40
A3 R
EPRO
DUCT
ION
SCAL
E
50
60
20
40
80
100
0mm
A1 R
EPRO
DUCT
ION
SCAL
E
No. AppdRevision Chk.V Date
DO NOT SCALE
* Refer to Revision 1 for Original Signature
Scale (A1)
Scale (A3)Reduced
Dwg Check
Dsg Verifier
Drawn
Original Design
Date
Approved For Project:
IF IN DOUBT ASK.
Title: Drawing No:
Docu
ment
No.
Rev.
Drawing Plotted:
SH1 MACKAYS TO PEKA PEKA
RP 1012/0.00 TO 1023/5.00Document created for NZTA by M2PP Alliance, Level 2, 17-21 Whitmore St, WELLINGTON
DE
TA
IL D
ES
IGN
(D
ET
)
Construction*
By Chk
EXPRESSWAY
0mm
30
10
20
40
A3 R
EPRO
DUCT
ION
SCAL
E
50
60
20
40
80
100
0mm
A1 R
EPRO
DUCT
ION
SCAL
E
VB
C 21.07/14CERTIFIED ISSUE - REV C
AS SHOWN
AS SHOWN
SD
CDCVB
21/07/1421/07/14
M2PP-121-D-DWG-8605SHEET 14 NOISE WALL NB3-2.5M HIGH
3500 TRANSITION PANEL
ELEVATION 1 - NOISE WALL NB3 - EXPRESSWAY SIDE
RESIDENTIAL SIDE - MATERIAL TYPE A
EXPRESSWAY SIDE - MATERIAL TYPE B
SECTION A - NOISE WALL NB3 - 2.5M
VISUALISATION-RESIDENTIAL SIDE
VISUALISATION-EXPRESSWAY SIDE
ELEVATION 2 - NOISE WALL NB3 - RESIDENTIAL SIDE
CWB
CWB
TL4 FAIR FACED CONCRETE EXPRESSWAY BARRIER TO FRONT
A-
INDICATIVE PLANTING-FOR FULL PLANTING EXTENT REFER TO DWGS 8201-8203
PAINTED STEEL H-PILE POST
INDICATIVE PLANTING-FOR FULL PLANTING EXTENT REFER TO DWGS 8201-8203
INDICATIVE PLANTING-FOR FULL PLANTING EXTENT REFER TO DWGS 8201-8203
2500mm
m
in
3000mm CENTRES
3500mm MAX PANEL SIZE
MATERIALITY/FINISHES/EXAMPLES
FAIR FACED CONCRETE FINISH WITH MATT GRAFFITI GUARD
A B
B
-FAIR FACED CONCRETE WITH EXPOSED CONCRETE PATTERN. -CONCRETE PATTERN: VERTEX BY GRAPHIC CONCRETE-3 PATTERN SIZES: - PATTERN 1: SMALL - PATTERN2: MEDIUM - PATTERN 3: LARGE
EXPRESSWAY SIDERESIDENTIAL SIDE
SCALE 1:100 @ A3
SCALE 1:100 @ A3
PAINTED STEEL H-PILE POST
TL4 FAIR FACED CONCRETE EXPRESSWAY BARRIER
A
NB2
PATTERN 1
PATTERN 1
PATTERN 1PATTERN 2
PATTERN 2
PATTERN 2PATTERN 3
No. AppdRevision Chk.V Date
DO NOT SCALE
* Refer to Revision 1 for Original Signature
Scale (A1)
Scale (A3)Reduced
Dwg Check
Dsg Verifier
Drawn
Original Design
Date
Approved For Project:
IF IN DOUBT ASK.
Title: Drawing No:
Docu
ment
No.
Rev.
Drawing Plotted:
SH1 MACKAYS TO PEKA PEKA
RP 1012/0.00 TO 1023/5.00Document created for NZTA by M2PP Alliance, Level 2, 17-21 Whitmore St, WELLINGTON
DE
TA
IL D
ES
IGN
(D
ET
)
Construction*
By Chk
EXPRESSWAY
0mm
30
10
20
40
A3 R
EPRO
DUCT
ION
SCAL
E
50
60
20
40
80
100
0mm
A1 R
EPRO
DUCT
ION
SCAL
E
VB
C 21.07/14CERTIFIED ISSUE - REV C
AS SHOWN
AS SHOWN
SD
CDCVB
21/07/1421/07/14
M2PP-121-D-DWG-8606SHEET 15
NOISE WALL NB7-2.0M HIGH TIMBER PROPERTY BOUNDARY
NOISE FENCE
NB7 - BORED POSTS
NB7 - TYPICAL ELEVATION - EXPRESSWAY SIDE NB7 - TYPICAL PERSPECTIVE - EXPRESSWAY SIDE (BORED POSTS)
EXPRESSWAY SIDE (PAINTED, NO-CLIMB)
RESIDENTIAL SIDE - NATURAL FINISH
NB7 - DRIVEN POSTS
NB7 DRIVEN POSTS:
• DEPTH IN TO SAND 2000MM• DEPTH INTO PEAT 3000MM• POLES TO BE H5 TREATED• FIRST AND LAST 6 POSTS FROM END OF FENCE TO BE AT 800MM CENTRES• ALL POSTS IN BETWEEN TO BE AT 1400 CENTRES• PALINGS 100MM IN TO GROUND
NB7 BORED POSTS:
• DEPTH IN TO SAND 2000MM• DEPTH INTO PEAT 3000MM• POLES TO BE H5 TREATED• FIRST AND LAST 5 POSTS FROM END OF FENCE TO BE AT1200MM CENTRES• ALL POSTS IN BETWEEN TO BE AT 2400 CENTRES• PALINGS 100MM IN TO GROUND
NB7 TIMBER NOISE FENCE:• 2.0M HIGH• OVERLAPPING TIMBER PALINGS• NO-CLIMB SIDE FACING EXPRESSWAY• NZTA APPROVED STAIN - DARK GREEN / GREY• 30 YEAR DESIGN LIFE
COLOUR:
WOODSMAN
WATERBORNE
RESENE DATA SHEET
D57A
1200
2.0M
300
END OF FENCE
FENCE TERMINATION LENGTH - FIRST AND LAST 5 POSTS AT 1200 CENTRES
FENCE TERMINATION
LENGTH - FIRST AND
LAST 5 POSTS AT 1200
CENTRES
FENCE TERMINATION LENGTH - FIRST AND LAST 6 POSTS AT 800 CENTRES
STANDARD POSTS AT 2400 CENTRES
STANDARD POSTS AT 1400 CENTRES
END OF FENCE
2400
1400
800
INDICATIVE PLANTING
NOT TO SCALE
300
300
300
200
200
50MM OVERLAP
50MM OVERLAP
No. AppdRevision Chk.V Date
DO NOT SCALE
* Refer to Revision 1 for Original Signature
Scale (A1)
Scale (A3)Reduced
Dwg Check
Dsg Verifier
Drawn
Original Design
Date
Approved For Project:
IF IN DOUBT ASK.
Title: Drawing No:
Docu
ment
No.
Rev.
Drawing Plotted:
SH1 MACKAYS TO PEKA PEKA
RP 1012/0.00 TO 1023/5.00Document created for NZTA by M2PP Alliance, Level 2, 17-21 Whitmore St, WELLINGTON
DE
TA
IL D
ES
IGN
(D
ET
)
Construction*
By Chk
EXPRESSWAY
0mm
30
10
20
40
A3 R
EPRO
DUCT
ION
SCAL
E
50
60
20
40
80
100
0mm
A1 R
EPRO
DUCT
ION
SCAL
E
No. AppdRevision Chk.V Date
DO NOT SCALE
* Refer to Revision 1 for Original Signature
Scale (A1)
Scale (A3)Reduced
Dwg Check
Dsg Verifier
Drawn
Original Design
Date
Approved For Project:
IF IN DOUBT ASK.
Title: Drawing No:
Docu
ment
No.
Rev.
Drawing Plotted:
SH1 MACKAYS TO PEKA PEKA
RP 1012/0.00 TO 1023/5.00Document created for NZTA by M2PP Alliance, Level 2, 17-21 Whitmore St, WELLINGTON
DE
TA
IL D
ES
IGN
(D
ET
)
Construction*
By Chk
EXPRESSWAY
0mm
30
10
20
40
A3 R
EPRO
DUCT
ION
SCAL
E
50
60
20
40
80
100
0mm
A1 R
EPRO
DUCT
ION
SCAL
E
VB
C 21.07/14CERTIFIED ISSUE - REV C
AS SHOWN
AS SHOWN
SD
CDCVB
21/07/1421/07/14
M2PP-121-D-DWG-8801SHEET 16 CWB INTERSECTIONS
1.0m
12.0m7.5m
3.0mCYCLEWAY WALKWAY BRIDLEWAY
3.0mCYCLEWAY WALKWAY BRIDLEWAY
0.5mGABION
0.5mGABION
LOCAL R
OAD
1.0mGRASSEDGE
LOW PLANTING ADJACENT TO
WALKWAY
GABIONS
FOOTPATH
PAINTED
SURFACE
LOW PLANTING ADJACENT TO
WALKWAY
WELDED MESH GABION WITH OTAKI RIVER STONE WALL
CS2-
CS1-
CS1 - TYPICAL CYCLEWAY SECTION
CS2 - TYPE 1 CYCLEWAY ENTRANCE
GROUND LEVEL VIEW OF CYCLEWAY ENTRANCE
TYPE 1 CYCLEWAY ENTRANCE - PLANSCALE - 1:50
SCALE - 1:50
SCALE - 1:100