13
Exhibit BDE-AT-3

Exhibit BDE-AT-3...IEEE C57.12.28 Standard (para. 5.3 to 5.5 included), including the salt spray test − Lifting lugs meeting all of the requirements of the CSA C2.1-06 and CSA C2.2-06

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Exhibit BDE-AT-3...IEEE C57.12.28 Standard (para. 5.3 to 5.5 included), including the salt spray test − Lifting lugs meeting all of the requirements of the CSA C2.1-06 and CSA C2.2-06

Exhibit BDE-AT-3

Page 2: Exhibit BDE-AT-3...IEEE C57.12.28 Standard (para. 5.3 to 5.5 included), including the salt spray test − Lifting lugs meeting all of the requirements of the CSA C2.1-06 and CSA C2.2-06
Page 3: Exhibit BDE-AT-3...IEEE C57.12.28 Standard (para. 5.3 to 5.5 included), including the salt spray test − Lifting lugs meeting all of the requirements of the CSA C2.1-06 and CSA C2.2-06

solarworld.com

SW 260 POLY (33mm black frame)

Designed to withstand heavy accumulations of snow and ice

Every component is tested to meet 3 times IEC requirements

Sunmodule Plus:Positive performance tolerance

25-year linear performance warranty and 10-year product warranty

Glass with anti-reflective coating

-0/+5 Wp

Anti-ReflectiveCoating

TUV Power controlled: Lowest measuring tolerance in industry

World-class qualityFully-automated production lines and seamless monitoring of the process and mate-rial ensure the quality that the company sets as its benchmark for its sites worldwide.

SolarWorld Plus-SortingPlus-Sorting guarantees highest system efficiency. SolarWorld only delivers modules that have greater than or equal to the nameplate rated power.

25-year linear performance guarantee and extension of product warranty to 10 yearsSolarWorld guarantees a maximum performance digression of 0.7% p.a. in the course of 25 years, a significant added value compared to the two-phase warranties com-mon in the industry, along with our industry-first 10-year product warranty.*

*in accordance with the applicable SolarWorld Limited Warranty at purchase.www.solarworld.com/warranty

geprüteSicherheit

• Qualified, IEC 61215• Safety tested, IEC 61730• Blowing sand resistance, IEC 60068-2-68• Ammonia resistance, IEC 62716• Salt mist corrosion, IEC 61701• Periodic inspection

• Periodic inspection• Power controlled

Page 4: Exhibit BDE-AT-3...IEEE C57.12.28 Standard (para. 5.3 to 5.5 included), including the salt spray test − Lifting lugs meeting all of the requirements of the CSA C2.1-06 and CSA C2.2-06

SW-01-7162US-G 01-2015All units provided are imperial. SI units provided in parentheses. SolarWorld AG reserves the right to make specification changes without notice.

•Compatiblewithboth"Top-Down"and"Bottom"mountingmethods

• Grounding Locations:– 4 locations along the length of the

module in the extended flange.

1.14 (29)

0.43 (11)

1.30 (33)

THERMAL CHARACTERISTICS

NOCT 46 °C

TC Isc 0.051 %/°CTC Voc -0.31 %/°CTC Pmpp -0.41 %/°COperating temperature -40°C to 85°C

PERFORMANCE AT 800 W/m², NOCT, AM 1.5

Maximum power Pmax 192.4 Wp

Open circuit voltage Voc 34.8 VMaximum power point voltage Vmpp 28.5 VShort circuit current Isc 7.35 AMaximum power point current Impp 6.76 AMinor reduction in efficiency under partial load conditions at 25°C: at 200 W/m², 100% (+/-2%) of the STC efficiency (1000 W/m²) is achieved.

COMPONENT MATERIALS

Cells per module 60

Cell type Poly crystallineCell dimensions 6.14 in x 6.14 in (156mm x 156 mm)Front Tempered glass (EN 12150)Frame BlackanodizedaluminumWeight 39.7 lbs (18.0 kg)

ADDITIONAL DATA

Power sorting1 -0 Wp / +5 Wp

J-Box IP65Module leads PV wire per UL4703 with H4 connectors Module type (UL 1703) 1Glass Low iron tempered with ARC

SYSTEM INTEGRATION PARAMETERS

Maximum system voltage SC II / NEC 1000 V

Maximum reverse current 25 ANumber of bypass diodes 3

Design Loads* Two rail system 113 psf downward64 psf upward

Design Loads* Three rail system 178 psf downward64 psf upward

Design Loads* Edge mounting 178 psf downward41 psf upward

* Please refer to the Sunmodule installation instructions for the details associated with these load cases.

PERFORMANCE UNDER STANDARD TEST CONDITIONS (STC)*

1) Measuring tolerance (Pmax ) traceable to TUV Rheinland: +/- 2% (TUV Power Controlled).

Maximum power Pmax 260 Wp

Open circuit voltage Voc 38.4 VMaximum power point voltage Vmpp 31.4 VShort circuit current Isc 8.94 AMaximum power point current Impp 8.37 AModule efficiency m 15.51 %

*STC: 1000 W/m², 25°C, AM 1.5

Mod

ule

curr

ent [

A]

Module voltage [V]

1000 W/m²

800 W/m²

600 W/m²

400 W/m²

200 W/m²

100 W/m²

ISC

VOC

+-

65.9

5 (16

75)

4x

37.8 (961)

39.3

7 (10

00)

∅ 0.26 (6.6)

∅ 0.35 (9)

7.12(180.85)

4.20(106.65)

11.32(287.50)

43.3

0 (11

00)

∅ 0.35 (9)

39.4 (1001)1.30 (33)

SW 260 POLY (33mm black frame)

Page 5: Exhibit BDE-AT-3...IEEE C57.12.28 Standard (para. 5.3 to 5.5 included), including the salt spray test − Lifting lugs meeting all of the requirements of the CSA C2.1-06 and CSA C2.2-06

1 / 8

FS System™ Ground Mount System

1 / 2© Schletter Inc • 1001 Commerce Center Drive • Shelby, North Carolina 28150 • Tel: (888) 608 - 0234 • Fax: (704) 595 - [email protected] • www.schletter.us

The Schletter FS System has a proven product performance and installation history, with over 8 GW installed worldwide. When purchasing an FS System, be con�dent in knowing product performance and safety are designed into every Schletter system.

Project speci�c engineering is available while optimized material usage addresses the ever-increasing need to reduce costs. When ordering a Schletter system, complete structural calculations are provided for the design, assuring compliance with current building codes and regulations.

The FS System is the result of experience gained through years of project planning and implementation. The system is enhanced with new support designs that includes the highest level of pre-fabrication and can accommodate nearly any type of PV module currently on the market. The result is a durable attractive system installed quickly and e�ciently.

The FS System purlins feature a pro�le geometry that is designed for optimal distribution of forces. Purlins are attached to the girder by means of special mounting claws that are pre-assembled in the exact position required for the chosen module. Bolt channels are integrated in all pro�les for more e�cient �eld installation.

Design Process

Thorough soil investigation and pull out test of post at the project site.

Layout planning using Helios 3D™ layout software.

For more information on all Schletter products and services, please visit www.schletter.us or call 1-888-608-0234.

What to Expect from Schletter• When other mounting providers say it can’t be done, with

Schletter, it can

• 100% IBC 2006, 2009, or 2012 code compliant systems, with PE wet stamps available in most states

• Exceeding the competition in providing quality steel and aluminum products

• Team of engineers o�ering full in-house services

• In-house geotechnical services

• Highly automated production for the fastest turnaround time in the industry

• Over 20-years solar mounting engineering and manufacturing experience

FS System

• Conforms to UL SUB 27031

• Certi�ed to ULC/ORD STD C1703

• High level of pre-assembled components

• Industry leading installation time

• Made of high quality sustainable aluminum

• Highly adjustable

Page 6: Exhibit BDE-AT-3...IEEE C57.12.28 Standard (para. 5.3 to 5.5 included), including the salt spray test − Lifting lugs meeting all of the requirements of the CSA C2.1-06 and CSA C2.2-06

2 / 8

FS System™ Ground Mount System

2 / 2 © Schletter Inc • 1001 Commerce Center Drive • Shelby, North Carolina 28150 • Tel: (888) 608 - 0234 • Fax: (704) 595 - [email protected] • www.schletter.us

Technical Data

Material • Fastening elements, bolts: Stainless steel 304 and 316• Profiles (rails): Aluminum alloy 6105 T5 • High life-expectancy, high residual value, no disposable cost• Pile-driven support posts: Steel, galvanized, ASTM A123 Grade 75

Logistics • Industry leading installation time of 330 man-hours per megawatt• Maximum level of prefabrication prior to shipment

Delivery and Services

• Geotechnical investigation and structural analysis

Structural Analysis

• Structural analysis based on a geotechnical investigation for local terrain condition • P.E. stamped drawings and calculations• Individual systems analysis based on local load values• Design loads according to IBC 2006, 2009, or 2012 (ASCE 7-05, ASCE 7-10)• Highly efficient, material-saving profile geometries• Verification of all construction components based on FEM-calculation

Warranty and Certi�cations

• 20-year limited warranty• Conforms to UL SUB 2703• Certified to UL/ORD STD C1703

I400

220U

S 1

0201

5

1The FS System is evaluated for electrical bonding only. The FS System meets all IBC and ASCE requirements for structural loading; it has not been evaluated for loading under UL 2703.

Connect Multiple Racks

For PV installations with more than one mounting system, electrically bonding individual racks is easy and a�ordable with Schletter’s Bonding Jumper.• Connects directly to purlin • Available in 6-inch to 48-inch lengths• Electrically bonds adjacent systems forming a continuous

ground path

Kinn

y Co

nstr

uctio

n

Quick, On-Site System Installation

• Foundation posts are quickly installed using GAYK hydraulic ram

• Place the support on post attachment head and bolt lower strut

• Insert locking wedge into attachment head

• Install purlins

• Install module using adapted versions of Schletter’s grounding Rapid2+™ clamps

Order an FS System On-line!Ideally suited for projects of 50 kW or smaller in size, using 60 or 72 cell modules, PV Powersite makes ordering convenient and fast. Users are provided with a permit-ready package which includes:• Structural acceptance letter• System drawings• Parts list

Page 7: Exhibit BDE-AT-3...IEEE C57.12.28 Standard (para. 5.3 to 5.5 included), including the salt spray test − Lifting lugs meeting all of the requirements of the CSA C2.1-06 and CSA C2.2-06

Single phase overhead distributiontransformers 10 kVA through 167 kVA

Distribution transformers

Page 8: Exhibit BDE-AT-3...IEEE C57.12.28 Standard (para. 5.3 to 5.5 included), including the salt spray test − Lifting lugs meeting all of the requirements of the CSA C2.1-06 and CSA C2.2-06

2 Single phase overhead distribution transformers

Product overview

ApplicationThe ABB overhead transformer may be used alone for the supply of a single phase load or as one of three units in a bank for the supply of a three phase load. The unit may be direct-mounted to a wooden or concrete pole, or cluster mounted on a pole for three phase use. The ABB transformers are designed for servicing residential overhead distribution loads. They are also suitable for light commercial loads, industrial lighting and diversified power applications.

StandardsAll units are built in accordance with both CAN CSA C2.1-06 and CAN CSA C2.2-06, except as modified to comply with customer specifications. IEEE C57.12.20 or International Electrotechnical Commission Standard (IEC) may apply if required.

FeaturesCore and coils designed for an optimum Total Ownership Cost −(TOC)Wound core with step-lap joints for increased efficiency and −lower noise levels“Low-high-low” windings for increased short circuit strength, −efficiency and thermal strengthComputer aided design for mechanical & electrical calculations −(C.A.D.)Dual voltage designed to meet BIL and short circuit require- −ments on both connectionsLow voltage leads with embossed markings on all units with 3 −LV bushings for easy reading and permanent identification on selected ratingsPaint system meeting or exceeding the performance of the −IEEE C57.12.28 Standard (para. 5.3 to 5.5 included), including the salt spray testLifting lugs meeting all of the requirements of the CSA C2.1-06 −and CSA C2.2-06 Standard (including feature to prevent sling slippage)Multiple cover clamps to ensure proper sealing and to mini- −mize water retention on the cover edgeCover or sidewall mounted high voltage bushing(s) as required −Low voltage spade or clamp type (basket) terminals as re- −quiredProvision for surge arrester bracket, bracket available as an −optionAutomatic self-resealing pressure relief valve −

Dual Voltage Transformers and TapsDual voltage transformers have proven to be very useful for their versatility which allows lower inventories for the electric utilities

and saves on change out costs in the event of upgrading to higher system voltage. Because taps are also in common use, it is appropriate that dual voltage transformers with taps be considered. As the transformer reliability is adversely affected by the increased number of HV leads introduced by dual voltage designs, ABB recommends the following:

Dual Voltage transformers without taps should be limited to a −4:1 ratio ( eg 2.4 x 8.0 kV)If taps are required on both connections, the voltage ratio −should be 2:1

Accordingly, ABB recommends that:(1) dual voltage transformers without taps be limited to a

maximum HV spread of 2400V x 8000V, or 4800V x 16000V, and that

(2) transformers with taps (for both connections) be limited to a maximum spread of 2.1, for example 7200V x 14400V, or 8000V x 16000V.

Pole Mounted Transformers, Rating DetailsGeneral technical information is listed below. Information on less common requirements can be obtained through your ABB sales representative.

kVA: 10, 15, 25, 37, 50, 75, 100, 167 −Temperature rise : 65 °C −Cooling type : ONAN −Single Phase −Hertz : 60, 50 −Polarity : Additive or Subtractive −Primary Voltage : 2400V through 34500 GrdY / 19920V −Secondary Voltage : 120 / 240V, 240 / 480 V, 347V, 600V −Insulation Class : 25kV (150kV BIL) and below −Taps: none, or as an option, 4 x 2,5% HV (any combina- −tion of full capacity above nominal and /or reduced capacity below nominal)

OptionsFour HV winding taps complete with externally operated −tapswitchDual voltage primary complete with externally operated volt- −age switchExtra creep bushing −Surge arrester bracket −Internal Fault Detector (IFD) −Non conductive transformer cover −Biodegradable vegetable oil (BIOTEMP®) −Stainless steel tank and cover −

Andy
Oval
Andy
Oval
Page 9: Exhibit BDE-AT-3...IEEE C57.12.28 Standard (para. 5.3 to 5.5 included), including the salt spray test − Lifting lugs meeting all of the requirements of the CSA C2.1-06 and CSA C2.2-06

Single phase overhead distribution transformers 3

Outline dimensions

Typical Dimensions (mm) for grain oriented electrical design

KVA A B C D Mass (kg) Oil (litres)

10 885 560 500 525 100 22

25 935 610 560 590 160 30

50 1035 710 635 675 260 60

75 1035 710 745 840 375 90

100 1135 815 770 965 555 100

167 1335 1015 795 890 690 160

Outline DrawingsThe influence of the loss evaluation formulae on transformer designs will lead to a wide variety of sizes and weights, thereby making it difficult, for the purpose of this information sheet, to cover the broad range of dimensions.

Andy
Oval
Page 10: Exhibit BDE-AT-3...IEEE C57.12.28 Standard (para. 5.3 to 5.5 included), including the salt spray test − Lifting lugs meeting all of the requirements of the CSA C2.1-06 and CSA C2.2-06

1LC

A00

0003

-LTE

Sep

tem

ber

2010

ABB Inc. Pole mounted Distribution Transformers 500 rue du Binôme.Québec, (Québec) G1P 4P1 CanadaPhone: +1 418 650 4488Fax: +1 418 650 2021

www.abb.com/transformers

Note:We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction–in whole or in parts–is forbidden without ABB’s prior written consent.

Copyright 2010 ABB.

All rights reserved

Contact us

Page 11: Exhibit BDE-AT-3...IEEE C57.12.28 Standard (para. 5.3 to 5.5 included), including the salt spray test − Lifting lugs meeting all of the requirements of the CSA C2.1-06 and CSA C2.2-06
Page 12: Exhibit BDE-AT-3...IEEE C57.12.28 Standard (para. 5.3 to 5.5 included), including the salt spray test − Lifting lugs meeting all of the requirements of the CSA C2.1-06 and CSA C2.2-06

SG 60KU-M

Efficiency Curve

Effi

cien

cy

Normalized Output Power

90%

92%

94%

96%

98%

100%

0% 20% 40% 60% 80% 100%

Vdc=550V

Vdc=710V

Vdc=850V

High flexibility for complex configurations due to 4

MPP trackers and a wide input voltage range

High yields due to efficiency up to 98.9% and CEC

efficiency of 98.5%

Output power up to 66kVA / 60kW at power factor of 1

Product certification: UL 1741, IEEE 1547, IEEE1547.1,

CSA C22.2 107.1-01-2001, FCC Part 15 Sub-part B

Class B Limits

Manufacturer certification: ISO 9001, ISO 14001,

OHSAS 18000

Efficient and flexible

ReliableIntegrated combiner box: 16 x Screw terminal pairs

with DC string fuses (both positive and negative), Type

II overvoltage protection(both DC and AC), DC and

AC switch, more safety and lower the system cost

Integrated string detection function and arc fault

detection

Intelligent design

Active power continuously adjustable (0~100%)

Fulfill a variety of reactive power adjustment

requirments with power factor 0.8 overexited ~ 0.8

underexited

Integrated LVRT and HVRT function

Includes RS-485 and Ethernet interface, compatible

with all common monitoring systems

Grid-friendly

www.sungrowpower.com

PV Grid-Connected Inverters 2015~2016 V121

Specifications subject to change without notice.

Page 13: Exhibit BDE-AT-3...IEEE C57.12.28 Standard (para. 5.3 to 5.5 included), including the salt spray test − Lifting lugs meeting all of the requirements of the CSA C2.1-06 and CSA C2.2-06

Max. PV input powerMax. PV input voltageStartup voltageStop VoltageMPP voltage rangeMPP voltage range for nominal powerString FuseNo. of MPPTsMax. number of PV strings per MPPTMax. PV input currentMaximum DC short circuit currentMax. current for input connectorMax. Cable SizeArc Flash DetectionDC SwitchInsulation DetectionDC Surge Arrestor

String InverterInput Side Data

Output Side Data

Protection

System Data Communication

Mechanical Data

Nominal AC output powerMax AC output power (PF=1)Max. AC output apparent powerMax. AC output currentNominal AC voltageAC voltage rangeNominal grid frequencyGrid frequency rangeTHDDC current injectionPower factorMax. Cable SizeAC Surge Arrestor

Anti-islanding protectionLow Voltage Ride ThroughDC reverse connection protectionAC short circuit protectionLeakage current protectionOvervoltage protectionAC switch

Max. efficiencyCEC efficiencyIsolation methodIngress protection ratingTare LossOperating ambient temperature rangeAllowable relative humidity rangeCooling methodMax. operating altitudeDisplayCommunicationDC connection typeAC connection typeCertificationSafety and EMC Standard

RS485EthernetI/O dry contactProtocol

Dimensions (W*H*D)Mounting methodWeight

78500W 1000V 300V 280V 300~950V550~850V / 513~850V Positive and Negative 4 4 112A (28A/28A/28A/28A) 200A 12A 10AWG, Cu or Al Yes Yes Yes Type II DIN rail surge arreste

60000W / 56000W66000W66000VA80A3Ǿ/3W +Ground, 480Vac 422~528Vac 60Hz55~65Hz<3% (Nominal power) <0.5%In >0.99@default value at nominal power, (adj. 0.8 eading ~ 0.8 lagging) 0AWG, Cu or Al Type II DIN rail surge arreste (40kA)

Yes Yes Yes Yes Yes Type II DIN rail surge arresterYes

98.90%98.50%TransformerlessNEMA4X<1W -25~60℃ (>50℃ derating) -13…+140℉ (>122℉ derating) 0~100% Smart forced air cooling4000m (>3000m derated) 13,000ft (>9,800ft derated)Graphic LCD RS485 / Ethernet Screw terminals Screw clamp terminalcCSAusUL 1741, IEEE 1547, IEEE1547.1, CSA C22.2 107.1-01-2001, FCC Part 15 Sub-part B Class B Limits

Standard Standard Standard Modbus

665*915*276 mm 26.2*36*10.9inchWall bracket70kg 154lbs

Circuit Diagram

DC SwitchCURRENTREADING

DC

1 In MPPT1

(Boost)

L2

N

PE

L1

L3

LCD/RS485DSP+CPLD

MPPT2(Boost)

MPPT3(Boost)

MPPT4(Boost)

DC

2 In

DC

3 In

DC

4 In

DC EMC Filter

DC EMC Filter

DC EMC Filter

DC EMC Filter

DC SPDDC FUSE

FansAuxiliary Power Circuit

DC Bus InverterCircuit AC

Reactor

Relay

ACEMCFilter

To G

rid

AC Switch

AC SPD