1.6 1.4 1.2 1 .8 .6 .4 .2 0 0 5 10 15 20 25 30 35 40 45 50 DYNAMIC RESPONSE REQUIREMENTS Eight transducers analyzed and plotted on a Gardner 1,2 curve DAMPING COEFFICIENT NATURAL FREQUENCY (Hz) HR 120 ADEQUATE HR 90 FAIR Systolic overshooting POOR LASS models do not contain DEHP • Di (2-ethylhexyl) phthalate is a chemical that makes PVC more flexible. 3,4 • Edwards has selected Acetyl TriButyl Citrate (ATBC) as the pri- mary option to replace DEHP due to its higher level of patient safety and signal quality. 5 Ensuring Safety, Accuracy and Reliability for Pressure Monitoring Edwards Lifesciences is the global leader in hemodynamic and pressure monitoring. Leveraging over 50 years of experience The Edwards TruWave disposable pressure transducers have the highest performance 1 When combined with a VAMP (Venous Arterial blood Management Protection) system, they offer the right combination for safety, accuracy and reliability. New Sampling Site Luer-activated sampling site (LASS) can be accessed with any luer-slip or luer-lock device, negating the need for a cannula. Efficient Sampling and Pressure Monitoring • Allows priming/flushing in a closed system; no need to flush the side port. • Side port can be closed to assure accurate pressure monitoring without signal damping. • Enables in-line flushing with minimal internal volume (0.25ml) after blood sampling. TruWave Smiths LogiCal Smiths TranStar B. Braun Pulsion CODAN/pvb Abbott/Hospira/ICU Medical BD/Argon Higher heart rates are characterized by rapidly rising systolic upstrokes; accurate pressure monitoring under this condition requires a superior transducer like the TruWave disposable pressure transducer. The proven pressure monitoring choice Excellent natural frequency Superior damping coefficient ensuring waveform accuracy 1 Most widely-used disposable pressure transducer in the world PHT DEHP

Ensuring Safety, Accuracy and Reliability for Pressure ... · PDF fileFor professional use. See instructions for use for full prescribing information, including indications, contraindications,

Embed Size (px)

Citation preview

1.6

1.4

1.2

1

.8

.6

.4

.2

00 5 10 15 20 25 30 35 40 45 50

DYNAMIC RESPONSE REQUIREMENTSEight transducers analyzed and plotted on a Gardner1,2 curve

DA

MPI

NG

CO

EFFI

CIE

NT

NATURAL FREQUENCY (Hz)

HR 120ADEQUATE

HR 90FAIR

Systolic overshootingPOOR

TruWaveSmiths LogiCalSmiths TranStarB. Braun

PulsionCODAN/pvbAbbott/Hospira/ICU MedicalBD/Argon

LASS models do not contain DEHP

•Di(2-ethylhexyl)phthalateisachemicalthatmakesPVCmoreflexible.3,4

•EdwardshasselectedAcetylTriButylCitrate(ATBC)asthepri-maryoptiontoreplaceDEHPduetoitshigherlevelofpatientsafetyandsignalquality.5

Ensuring Safety, Accuracy and Reliability for Pressure Monitoring

Edwards Lifesciences is the global leader in hemodynamic and pressure monitoring.

• Leveragingover50yearsofexperience

• TheEdwardsTruWavedisposablepressuretransducershavethehighestperformance1

• WhencombinedwithaVAMP(VenousArterialbloodManagementProtection)system,they offertherightcombinationforsafety,accuracyandreliability.

New Sampling Site

Luer-activatedsamplingsite(LASS)canbeaccessedwithanyluer-sliporluer-lockdevice,negatingtheneedforacannula.

Efficient Sampling and Pressure Monitoring

•Allowspriming/flushinginaclosedsystem;noneedtoflushthesideport.

•Sideportcanbeclosedtoassureaccuratepressuremonitoringwithoutsignaldamping.

•Enablesin-lineflushingwithminimalinternalvolume(0.25ml)afterbloodsampling.

1.6

1.4

1.2

1

.8

.6

.4

.2

00 5 10 15 20 25 30 35 40 45 50

DYNAMIC RESPONSE REQUIREMENTSEight transducers analyzed and plotted on a Gardner1,2 curve

DA

MPI

NG

CO

EFFI

CIE

NT

NATURAL FREQUENCY (Hz)

HR 120ADEQUATE

HR 90FAIR

Systolic overshootingPOOR

TruWaveSmiths LogiCalSmiths TranStarB. Braun

PulsionCODAN/pvbAbbott/Hospira/ICU MedicalBD/Argon

Higher heart rates are characterized by rapidly rising systolic upstrokes; accurate pressure monitoring under this condition requires a superior transducer like the

TruWave disposable pressure transducer.

The proven pressure monitoring choice

• Excellentnaturalfrequency

• Superiordampingcoefficientensuring waveformaccuracy1

• Mostwidely-useddisposablepressure transducerintheworld

PHT

DEHP

For professional use. See instructions for use for full prescribing information, including indications, contraindications, warnings, precautions and adverse events.

Edwards Lifesciences devices placed on the European market meeting the essential requirements referred to in Article 3 of the Medical Device Directive 93/42/ECC bear the CE marking of conformity.

Edwards, Edwards Lifesciences, the stylized E logo, TruWave, VAMP, VAMP Flex and VAMP Plus are trademarks of Edwards Lifesciences Corporation. All other trademarks are the property of their respective owners.

© 2013 Edwards Lifesciences Corporation. All rights reserved. E4441/10-13/CC

Edwards Lifesciences I edwards.comRoute de l’Etraz 70 I 1260 Nyon, Switzerland USA I Japan I China I Brazil I Australia I India

Individual choice for your needs

Z-site port*12 cc reservoir and contamination shield

Contamination shield 10 cc reservoir

Z-site port*

Contamination shield

5 cc reservoir

Snap-Tab flush device

Gold-plated connector wires

ICU - VAMP Adult System•Convenientbloodsamplinginclose proximitytopatients

•Lessbloodwaste

• Infectioncontrol

VAMP Flex System•WithaZ-siteportclosetothepatientand onepole-mounted

•Makesanexcellentchoiceforproviding clinicianandpatientsafetyinbothORandICU

OR - VAMP Plus System•Optimalforsamplingduringand aftersurgery

•Biggerreservoirofferstheabilityto samplebloodproximallyordistally

*Z-site port can be replaced by the new luer-activated sampling site.

References

1. Jean-François Cochard, Performance Evaluation of European Pressure Sensors. ICU Management, September 2005

2. Reed M. Gardner, Direct Blood Pressure Measurement. Anesthesiology, March 1981

3. National Toxicology Program (NTP) Expert Panel Report: NTP – CERHR Expert Panel Report on Di (2-ethylhexyl) phthalate. National Toxicology Program, U.S. Department of Health and Human Services, Center for the Evaluation of Risks to Human Reproduction, October 2000. http://cerhr.niehs.gov/news/index.html

4. Food and Drug Administration (FDA) Safety Assessment: Safety Assessment of Di (2-ethylhexyl) phthalate (DEHP) Released from PVC Medical Devices. Center for Devices and Radiological Health, September 2001. www.fda.gov/cdrh/ost/dehp-pvc.pdf.

5. Food and Drug Administration (FDA) Public Health Notification: PVC Devices Containing the Plasticizer DEHP. Center for Devices and Radiological Health, July 2002. www.fda.gov/cdrh/safety/dehp.html

TruWave Sensor•Rightcombinationforsafety, accuracyandreliability.

•Excellentnaturalfrequency

•Superiordampingcoefficient ensuringwaveformaccuracy