System Specification
EnOceanoverIPProfiles Page1/18
Intro:EnOceanoverIPProfilesIntro
V0.91
Approvedforfirstrelease:Approvedforsecondrelease:
Approvedforfinalrelease:SanRamon,CA,USA,2016
ExecutiveSummary
Ver. Editor Change Date
0.9 TH Firstversion December5.2016
0.9.1 BE IP-Profiles(JPG)added December6.2016
System Specification
EnOceanoverIPProfiles Page2/18
Inhalt
1. Introduction..........................................................................................................32. Profiles..................................................................................................................4
2.1.F6-01-01:PushButton..........................................................................................42.2.F6-02-01:RockerSwitch,2Rocker.......................................................................52.3.F6-10-00:MechanicalHandle,WindowHandle...................................................72.4.A5-02-02:TemperatureSensors,Range-30°Cto+10°C.......................................9
2.5.A5-06-01:LightSensor,Range300lxto60.000lxIPv0.9.....................................102.6.A5-07-01:OccupancySensor,OccupancywithSupplyvoltagemonitor............112.7.A5-09-05:GasSensor,VOCSensor.....................................................................122.8.A5-20-04:HVACComponents,HeatingRadiatorValveActuatingDrivewithFeedandRoomTemperatureMeasurement,LocalSet....................................................14
System Specification
EnOceanoverIPProfiles Page3/18
24 1.Introduction
25 ThereleaseoftheEnOceanoverIPprofilespecificationwillbedoneinparts,duetotheextent26 ofthedocument(severalhundredsofpages).
27 Thefirstpreliminaryreleaseincludesasmallsubsetofprofiles.Eventhoughthislistwillbe28 extendedinthenearfuture,theseprofilesareagoodstarttogetanoverviewandideahow29 theEEPsareshownintheIPworld.
30
System Specification
EnOceanoverIPProfiles Page4/18
2.Profiles 2.1.F6-01-01:PushButton
MostsimpleprofilewithonesinglebittranslatedintoEnOceanoverIP:
IP-profile:
System Specification
EnOceanoverIPProfiles Page5/18
2.2.F6-02-01:RockerSwitch,2Rocker
Profilewherealmosteverythingwaschanged:
• Theideaofanapplicationlevelmeaninglike“switchlighton”or“moveblindclosed”wasgivenup,youseethe4buttonsonly.Pleasenote,thatfortheverysamereasonthere is no difference between the representation of F6-02-01 and F6-02-02 in theEnOceanoverIPworld.
• Thequitecomplexlogicof“firstrockeraction”+“secondrockeraction”+“energybowstate”ishiddenintheEnOceanoverIPrepresentation
• Theadditionalmessage“3or4buttonspressedsimultaneously”isextractedin anadditionalfunctiongroup
System Specification
EnOceanoverIPProfiles Page6/18
IP-profile:
System Specification
EnOceanoverIPProfiles Page7/18
2.3.F6-10-00:MechanicalHandle,WindowHandle
Alistof8differentstateswastransferredin3simplepositionswithoutlosinganyinformation:
System Specification
EnOceanoverIPProfiles Page8/18
IP-profile:
System Specification
EnOceanoverIPProfiles Page9/18
2.4.A5-02-02:TemperatureSensors,Range-30°Cto+10°C
Exampleofasimpleprofile,usingavaluerange.
IP-profile:
System Specification
EnOceanoverIPProfiles Page10/18
2.5.A5-06-01:LightSensor,Range300lxto60.000lxIPv0.9
In thisprofile theEnOceanover IP representationmerges twodifferentvalue ranges inonefunction
IP-profile:
System Specification
EnOceanoverIPProfiles Page11/18
2.6.A5-07-01:OccupancySensor,OccupancywithSupplyvoltagemonitor
• “PIRstatus”with“analog”value0-255 is transferredto“motionDetected”withBooleanvalue
• “Supply voltageavailable” ishidden internally.Only if this flag is set, EO/IP function“supplyVoltage”willbeshown
• “Supplyvoltage”values251-255aremigratedto“errorCode”
IP-profile:
System Specification
EnOceanoverIPProfiles Page12/18
2.7.A5-09-05:GasSensor,VOCSensor
• Different“VOCID”saretransferredtodifferentEO/IPfunctions • The“ScaleMultiplier”iscalculatedinternally
System Specification
EnOceanoverIPProfiles Page13/18
IP-profile:
System Specification
EnOceanoverIPProfiles Page14/18
2.8.A5-20-04:HVACComponents,HeatingRadiatorValveActuatingDrivewithFeedandRoomTemperatureMeasurement,LocalSet
• Bidirectionalprofilewithtwofunctiongroups:InEO/IPdirection“from”means“fromdevicetoAPI”,direction“to”means“fromAPItodevice”
• “Current Position” on “Direction one” and “Valve Position” on “Direction two” aretranslatedtofunction“valve”onEO/IPrepresentation
• “FeedTemperatureORTemperatureSetPoint”and“TemperatureSelection”areseparatedtotwofunctions“feedTemperature”and“temperatureSetpoint”
• “Wake-upCycle”with63differentvaluesistranslatedtofunction“wakeUpCycle”with tworangesandasinglevalue
System Specification
EnOceanoverIPProfiles Page15/18
System Specification
EnOceanoverIPProfiles Page16/18
System Specification
EnOceanoverIPProfiles Page17/18
System Specification
EnOceanoverIPProfiles Page18/18