VFSTR Journal of STEM Vol. 01, No. 01 (2015) xxxx-xxxx
23
Engineering Mechanical Engg
Design and Simulation of a Capacitive Micro Bridge Type Accelerometer for μg Applications S. S. A. Hasanth Pulavarthy1, B. Ramamoorthy2,* 1Ashok Leyland, Chennai, M.Tech IIT-M, India. 2Rector, Vignan’s Foundation for Science, Technology and Research University (VFSTR Univ. VIGNAN UNIVERSITY), Vadlamudi, Guntur 522 213 Andhra Pradesh, INDIA.
*Corresponding Author: Tel.: +91-863-234-4700 Ext.: 401 Fax: +91-863-253-4468 E-mail: [email protected]
ARTICLE HISTORY
Received 1 August 2015
Revised 20 September 2015
Accepted 25 September 2015
Available online 1 October 2015
GRAPHICAL ABSTRACT
ABSTRACT The objective of this work is to simulate the mechanical behaviour of two different types of precision μg micro electromechanical systems (MEMS) accelerometers and determine the optimal design of capacitive micro bridge type accelerometer by comparing their performance as a function of their respective displacements and stresses. The structure of the accelerometer consists of a proof mass which is suspended by tether beams between fixed rigid electrodes to provide differential capacitance measurements. The analysis of displacement and stress of the accelerometers have been performed in FEM simulation software COMSOLTM. The limitations of one of the models, i.e., the two beam accelerometer have been discussed and one of the possible solutions, i.e., the four beam accelerometer has been discussed in detail. Sensitivity analysis has been presented for the aforementioned accelerometers. The process flow diagrams for the fabrication of the final model of the accelerometer have been simulated in IntellisuiteTM . Results of the simulation and analysis show that the two beam accelerometer proved to be more sensitive than its four beam counterpart. However, the four beam accelerometer proved to be mechanically stable. The four beam accelerometer is also subjected to lower stresses and it has linearity over the entire operational range where as the two beam accelerometer is subjected to higher stresses and also has non linearity when the entire operational range is considered.
Keywords: MEMS; Capacitive Accelerometer; Displacement; Stress; Sensitivity; COMSOL TM; IntellisuiteTM .
© 2015 VFSTR Press. All rights reserved XXXX-XXX | http://dx.doi.org/xx.xxx/xxx.xxx.xxx |
VFSTR Journal of STEM Vol. 01, No. 01 (2015) xxxx-xxxx
24
1. INTRODUCTION
Micro electromechanical Systems (MEMS) is the integration of mechanical elements, sensors, actuators, and electronics on a common silicon substrate through micro fabrication technology. MEMS technology can be implemented using a number of different materials and manufacturing techniques; the choice of which will depend on the device being created and the market sector in which it has to operate. These devices generally integrate signals from one physical domain to another, such as mechanical to electrical, electrical to mechanical, electrical to chemical (Stephen Beeby et al, 2004). A key contribution of the development of MEMS technology is that it has enabled the integration of sensors, actuators and signal processing on a single chip (Eddy et al, 1998), and their integration has positive effects upon performance, reliability and cost. The ability to integrate actuators on chip leads to the possibility of new distributed control systems (Frank et al, 2000). The performance of MEMS sensors being superior to macro sensors in terms of resolution and maximum frequency, make them viable for their usage as a variety of commercial MEMS sensors, such as accelerometers and pressure sensors. The low manufacturing costs and small package size also play a major role in the success of these devices (Bell et al, 2005). Single-crystal silicon is being increasingly employed in a variety of new commercial products not because of its well established electronic properties, but rather because of its excellent mechanical properties (Petersen, 1982). It is mechanically stable and it can be integrated into electronics on the same substrate. Silicon is almost an ideal structural material. It has about the same Young’s modulus as steel (about 2 x 105 MPa), but is as light as aluminum, with a mass density of about 2.3 g/cm3. Materials with a high Young’s modulus can better maintain a linear relationship between applied load and the induced deformations. In Microsystems or MEMS, silicon needs to withstand severe
mechanical and thermal loads. It is thus important to have a good understanding of the mechanical characteristics of silicon as a structural material. 2. Design of accelerometer
Design of the sensor Acceleration is a physical quantity gaining increasing interest in many systems with regard to monitoring, control or measurement applications. In the past there have been two distinct fields of accelerometry, vibration measurement and inertial guidance and navigation. For vibration measurement, requiring low sensitivity and large bandwidth, the piezoelectric approach is optimum and there are many commercially available sensors On the other hand, accelerometers for inertial guidance and navigation, are characterized by high precision, small bandwidth and low working ranges. Two silicon based approaches are presently in a well-advanced state of development; one is of the capacitive type (Rudolf et al, 1983) and the other of the piezo resistive type. While the fabrication costs of the two approaches are very similar, the capacitive approach has the advantage of higher stability, high reliability, lower power consumption, lower non-linearity, lower noise, lower temperature coefficients, higher overload resistance and gives a much higher sensitivity and resolution, reliability as well as low drift (Boser, 1996). Capacitive MEMS sensors are widely preferred in consumer applications due to their high performance and low cost. In this paper two different models of accelerometers are analyzed. The structure of either of the two accelerometers consists of three-layers, i.e., a bottom silicon layer (bottom electrode) adhering to the substrate, a top silicon layer (top electrode) also adhering to the substrate, and a middle layer of silicon suspended by tether beams (proof mass supported by tether beams). The middle layer, with the top and bottom layers respectively, forms two capacitors. When subjected to acceleration, the middle layer is deflected. This
VFSTR Journal of STEM Vol. 01, No. 01 (2015) xxxx-xxxx
25
motion results in change in capacitance for both capacitors, generating a differential output signal. Two Beam Accelerometer A two beam accelerometer is shown in Fig.1. It consists of a proof mass suspended by two tether beams, along with a top electrode and a bottom electrode. The dimensions of the accelerometer are given in Table 1. Fig.1. Model of the two beam accelerometer
Geometry dimension / Properties
Two beam model
Width of the beam (μm) 250
Length of the beam (μm) 700
Thickness of the beam (μm)
50
Width of the mass (μm) 2500
Length of the mass (μm) 2500
Thickness of the mass (μm)
500
Distance between electrodes (μm)
50
Free space permittivity (F/m)
8.8541878 x 10-12
Young modulus (Pa) 1.7 x 1011
Specific mass of material (kg/m3)
2230
Table.1. Parameters used for the two beam accelerometer
Fig.2. Meshed model of the two beam accelerometer The accelerometer is meshed fine in COMSOL as shown in Fig.2 and a point load equal to the magnitude of the subjected acceleration is applied at the midpoint of the top face of the proof mass. The two tether beams are fixed in all degrees of freedom. A voltage of 5V is applied to the top electrode while maintaining the bottom electrode as ground. The behaviour of the accelerometer is studied in the vibration range of 10μg - 60μg and the results are presented in Tables 3 – 6. The graphs are plotted and are shown in Figs. 26 – 29. Four beam accelerometer A four beam accelerometer is shown in Fig.3. It consists of a proof mass suspended by four tether beams, along with a top electrode and a bottom electrode. The dimensions of the accelerometer are given in Table 2.
Fig.3. Model of the four beam accelerometer
VFSTR Journal of STEM Vol. 01, No. 01 (2015) xxxx-xxxx
26
Geometry dimension / Properties
Two beam model
Width of the beam (μm) 250
Length of the beam (μm) 700
Thickness of the beam (μm)
50
Width of the mass (μm) 2500
Length of the mass (μm) 2500
Thickness of the mass (μm)
500
Distance between electrodes (μm)
10
Free space permittivity (F/m)
8.854 x 10-
12
Young modulus (Pa) 1.7 x 1011
Specific mass of material (kg/m3)
2230
Table.2. Parameters used for the four beam accelerometer Fig.4. Meshed model of the four beam accelerometer The accelerometer is meshed fine in COMSOL as shown in Fig.4 and a point load equal to the magnitude of the subjected acceleration is applied at the midpoint of the top face of the proof mass. The four tether beams are fixed in all degrees of freedom. A voltage of 5V is applied to the top electrode while maintaining the bottom electrode as ground. The behaviour of the accelerometer is studied in the vibration
range of 10μg - 60μg and the results are tabulated in Tables 7 – 10. The graphs are plotted and are shown in Figs. 30 – 33. Simulation of fabrication of the accelerometer
(a) (b) (c) Fig.5 (a) Mask 1 (b) Mask 2 (c)Mask 3, modeled in Intellisuite Surface micromachining is used for realization of the proof mass where as bulk micromachining is used for realization of the tether beams. The masks required for realization of the accelerometer have been modeled in IntellisuiteTM as shown in Fig. 5, and the process steps required for realization for the fabrication of the accelerometer are shown in Fig. 6.
Fig.6 Process flow steps followed for realization of the four beam accelerometer
Signal Processing of the accelerometer The differential capacitance accelerometer works on the principle of complementary changes of two capacitors with acceleration. For the two beam accelerometer shown in Fig.1, these changes are above and below the nominal
VFSTR Journal of STEM Vol. 01, No. 01 (2015) xxxx-xxxx
27
capacitance whose typical value is 13.17 pF. The maximum capacitance change with full-scale excitation is about 8.83 pF. For the two beam accelerometer shown in Fig.3, these changes are above and below the nominal capacitance whose typical value is 32.93 pF. The maximum capacitance change with full-scale excitation is about 25.7 pF. These small values of capacitance are critical for capacitance to voltage conversion schemes as the parasitics are introduced while integration with signal conversion electronics and packaging. A high input impedance inverting operational amplifier with feedback capacitor configured as charge amplifier can be used for capacitance to voltage conversion. The circuit is as shown in Fig. 7. The output voltage is made proportional to the total change in the differential capacitance. The common plate/ electrode connected to inverting input of the Op-amp and the other two terminals of the sensor are applied with square wave out of phase with each other. The feedback capacitor value determines the sensitivity of the unit (Boser, 1996). Fig.7. Signal condition circuit for four beam accelerometer 3. Results and Discussion
Two beam accelerometer
Displacement Analysis
Fig.8. Displacement of proof mass when subjected to an acceleration of 10μg along Z axis When the two beam accelerometer is subjected to an acceleration of 10 μg the maximum displacement of the proof mass is obtained as 7.604 μm as shown in fig. 9. The nominal value of the capacitance can be calculated as given below (Beeby, 2004): Hence the differential change in capacitance can be obtained as: When the proof mass deflects by a displacement of ‘x’ (μm), the capacitance changes as given below: Now the differential change in capacitance can be obtained as: In this case, x = 7.604 μm, d= 50 μm and A = 2500 μm x 2500 μm. Thus the differential capacitance obtained is about 4.10 pF. The ratio
(12)
(2)
(1)
(3)
(4)
VFSTR Journal of STEM Vol. 01, No. 01 (2015) xxxx-xxxx
28
∆C/C is about 0.311. The sensitivity of the accelerometer is about 31123.77. Fig.9. Displacement of proof mass when subjected to an acceleration of 20μg along Z axis When the two beam accelerometer subjected to an acceleration of 20 μg the maximum displacement of the proof mass is obtained as 15.21 μm as shown in fig. 9. In this case, x = 15.21 μm, d= 50 μm and A = 2500 μm x 2500 μm. Thus the differential capacitance obtained is about 8.33 pF. The ratio ∆C/C is about 0.670. The sensitivity of the accelerometer is about 33523.16. Fig.10. Displacement of proof mass when subjected to an acceleration of 30μg along Z axis When the two beam accelerometer subjected to an acceleration of 30 μg the maximum displacement of the proof mass is obtained as
22.81 μm as shown in fig. 10. Ideally this should be one-third of the nominal gap between the electrodes (i.e., atmost 16.67 μm). Since this condition has been violated, the capacitance values obtained are not considered since it leads to non linear behavior of the accelerometer. Thus the operational range of the two beam accelerometer is confined to 10 μg – 20 μg. Stress Analysis Stress analysis has been carried out in the finite element simulation software COMSOLTM by giving acceleration as input within the aforementioned range as an input and the results are presented in Figs. 11 -13. Fig.11. Stress on sensor when subjected to an acceleration of 10μg along Z axis Fig.12. Stress on proof mass when subjected to an acceleration of 20μg along Z axis
VFSTR Journal of STEM Vol. 01, No. 01 (2015) xxxx-xxxx
29
Fig.13. Stress on proof mass when subjected to an acceleration of 30μg along Z axis Four beam accelerometer
Displacement Analysis
Fig.14. Displacement of proof mass when subjected to an acceleration of 10μg along Z axis When the four beam accelerometer is subjected to an acceleration of 10 μg the maximum displacement of the proof mass is obtained as 1.147 μm as shown in fig. 14. The nominal value of the capacitance and the value of differential change in capacitance are calculated using the equations (1) to (4) mentioned earlier. In this case, x = 1.147 μm, d= 20 μm and A = 2500 μm x 2500 μm. Thus the differential capacitance obtained is about 3.79 pF. The ratio ∆C/C is about 0.115. The sensitivity of the accelerometer is about 11510.16.
Fig.15. Displacement of proof mass when subjected to an acceleration of 20μg along Z axis When the four beam accelerometer is subjected to an acceleration of 20 μg the maximum displacement of the proof mass is obtained as 2.294 μm as shown in fig. 15. In this case, x = 2.294 μm, d= 20 μm and A = 2500 μm x 2500 μm. Thus the differential capacitance obtained is about 8.46 pF. The ratio ∆C/C is about 0.257. The sensitivity of the accelerometer is about 12846.99. Fig.16. Displacement of proof mass when subjected to an acceleration of 30μg along Z axis When the four beam accelerometer is subjected to an acceleration of 30 μg the maximum displacement of the proof mass is obtained as 3.441 μm as shown in fig. 16. In this case, x = 3.441 μm, d= 20 μm and A = 2500 μm x 2500 μm. Thus the differential capacitance obtained is about 11.68 pF. The ratio ∆C/C is about 0.355.
VFSTR Journal of STEM Vol. 01, No. 01 (2015) xxxx-xxxx
30
The sensitivity of the accelerometer is about 11824.50. Fig.17. Displacement of proof mass when subjected to an acceleration of 40μg along Z axis When the four beam accelerometer is subjected to an acceleration of 40 μg the maximum displacement of the proof mass is obtained as 5.735 μm as shown in fig. 17. In this case, x = 5.735 μm, d= 20 μm and A = 2500 μm x 2500 μm. Thus the differential capacitance obtained is about 15.95 pF. The ratio ∆C/C is about 0.625. The sensitivity of the accelerometer is about 12110.49. Fig.18. Displacement of proof mass when subjected to an acceleration of 50μg along Z axis When the four beam accelerometer is subjected to an acceleration of 50 μg the maximum displacement of the proof mass is obtained as 5.735 μm as shown in fig. 18. In this case, x = 5.735 μm, d= 20 μm and A = 2500 μm x 2500 μm. Thus the differential capacitance obtained is
about 25.7 pF. The ratio ∆C/C is about 0.781. The sensitivity of the accelerometer is about 12494.69. Fig.19. Displacement of proof mass when subjected to an acceleration of 60μg along Z axis When the four beam accelerometer is subjected to an acceleration of 60 μg the maximum displacement of the proof mass is obtained as 6.883 μm as shown in fig. 19. In this case, x = 6.883 μm, d= 20 μm and A = 2500 μm x 2500 μm. Thus the differential capacitance obtained is about 15.95 pF. The ratio ∆C/C is about 0.484. The sensitivity of the accelerometer is about 13008.97.
Stress Analysis
Fig.20. Stress on sensor when subjected to an acceleration of 10μg along Z axis Stress analysis has been carried out in the finite element simulation software COMSOLTM by giving acceleration as input within the
VFSTR Journal of STEM Vol. 01, No. 01 (2015) xxxx-xxxx
31
aforementioned range as an input and the results are presented in Figs. 20 - 33.
Fig.21. Stress on sensor when subjected to an acceleration of 20μg along Z axis Fig.22. Stress on sensor when subjected to an acceleration of 30μg along Z axis
Fig.23. Stress on sensor when subjected to an acceleration of 40μg along Z axis
Fig.24. Stress on sensor when subjected to an acceleration of 50μg along Z axis Fig.25. Stress on sensor when subjected to an acceleration of 60μg along Z axis Two Beam Accelerometer
Acceleration (µg)
Total deflection (µm)
10 7.604
20 15.21
30 22.81
40 30.42
50 38.02
60 45.62
Table 3. Variation of displacement with respect to applied acceleration
VFSTR Journal of STEM Vol. 01, No. 01 (2015) xxxx-xxxx
32
Fig.26. Variation of displacement with respect to applied acceleration
Acceleration (µg) ∆C (pF)
10 0.3446
20 0.7419
30 1.2754
40 2.1376
50 3.9906
60 12.067
Table 4. Variation of change in capacitance with respect to applied acceleration
Change in capacitance Vs. Acceleration
0
20
40
60
80
100
120
140
160
0 10 20 30 40 50 60 70
Acceleration (µg)
Chan
ge in
cap
acit
ance
(pF)
Fig.27. Variation of change in capacitance with respect to applied acceleration
Acceleration (µg) ∆C/C
10 0.31135
20 0.67031
30 1.15233
40 1.93133
50 3.60553
60 10.90260
Table 5. Variation of change in capacitance per unit capacitance with respect to applied acceleration
∆C/C Vs. Acceleration
0
2
4
6
8
10
12
0 10 20 30 40 50 60 70
Acceleration (µg)
∆C
/C
Fig. 28. Variation of change in capacitance per unit capacitance with respect to applied acceleration
Acceleration (µg) ∆C/C
10 31134.803
20 33515.540
30 38411.035
40 48283.339
50 72110.589
60 181710.035
Table 6. Variation of sensitivity with respect to applied acceleration
Sensitivity Vs. Acceleration
0
50000
100000
150000
200000
0 10 20 30 40 50 60 70
Acceleration (µg)
Se
nsi
tiv
ity
Fig. 29. Variation of sensitivity with respect to applied acceleration
VFSTR Journal of STEM Vol. 01, No. 01 (2015) xxxx-xxxx
33
Four beam accelerometer
Acceleration (µg)
Total deflection (µm)
10 1.147
20 2.294
30 3.441
40 4.588
50 5.735
60 6.882
Table 7. Variation of displacement with respect to applied acceleration
Table 8. Variation of change in capacitance with respect to applied acceleration
Fig.30. Variation of displacement with respect to applied acceleration
Acceleration (µg) ∆C (pF)
10 3.79
20 7.65
30 11.68
40 15.95
50 20.57
60 25.7
Table 9. Variation of change in capacitance per unit capacitance with respect to applied acceleration
Fig.31. Variation of change in capacitance with respect to applied acceleration
∆C/C Vs. Acceleration
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
0 10 20 30 40 50 60 70
Acceleration (µg)
∆C/
C
Fig.32. Change in capacitance per unit capacitance with respect to applied acceleration
Acceleration (µg) ∆C/C
10 11510.66
20 11616.96
30 11824.5
40 12110.49
50 12494.69
60 13008.97
Table 10. Variation of sensitivity with respect to applied acceleration
Acceleration (µg) ∆C/C
10 0.115
20 0.232
30 0.355
40 0.484
50 0.625
60 0.781
VFSTR Journal of STEM Vol. 01, No. 01 (2015) xxxx-xxxx
34
Sensitivity Vs. Acceleration
11400
11600
11800
12000
12200
12400
12600
12800
13000
13200
0 20 40 60 80
Acceleration (µg)
Sens
itiv
ity
Fig.33. Variation of sensitivity with respect to applied acceleration 4. Conclusion In the present work, simulation of a two beam capacitive accelerometer and a four beam capacitive accelerometer has been carried out. The process flow steps involved in fabrication of the accelerometers have been indicated. Based on the simulation carried out and the analysis made by subjecting the accelerometers to acceleration in the aforementioned range, the following conclusions are drawn:
The two beam capacitive micro bridge type accelerometer has 4-8 % higher differential capacitance change
The two beam capacitive micro bridge type accelerometer has 60 -70 % higher ratio of differential capacitance change to unit capacitance
The two beam capacitive micro bridge type accelerometer has 61 – 64 % higher sensitivity than its four beam counterpart.
But the four beam capacitive micro bridge type accelerometer has many advantages such as
The mechanical stability of the four beam capacitive micro bridge type accelerometer is higher compared with its two beam counterpart.
The size of the four beam capacitive micro bridge type accelerometer is 10 % smaller than its two beam counterpart.
The four beam capacitive micro bridge type accelerometer is subjected to 60 % lower stresses than its two beam counterpart.
The four beam capacitive micro bridge type accelerometer exhibits linearity in the operational range.
Thus it is observed that behaviour of the four beam capacitive micro bridge type accelerometer is better that its two beam counterpart. Hence, the four beam capacitive micro bridge type accelerometer is suggested for the detection of vibration in the aforementioned range.
References [1] Acar, C. and Shkel, A. M. (2003), “Experimental
evaluation and comparative analysis of commercial variable-capacitance MEMS accelerometers”, Journal of Micromechanics and Microengineering, Vol. 13, pp. 634–645.
[2] Agarwal, V. and Banik, S. (2006), “Design steps for bulk micro machined single axis silicon capacitive accelerometer with optimized device dimensions”, International MEMS Conference, pp. 722-727.
[3] Babu, P. S. S. and Rao, P. K. (2008), “Design of Two Beam Capacitive Micromachined Acceleration Sensor and Its Displacement and Stress Analysis”, Asian Journal of Experimental Scence., Vol. 22, No. 3, pp. 351-356.
[4] Barbour, N. and Schmidt, G. (2001), “Inertial Sensor Technology Trends”, IEEE Sensors Journal, Vol. 1, No. 4, pp. 332-339.
[5] Beeby, S. (2004), “MEMS Mechanical Sensors”, Artech House Inc.
[6] Bell, D. J. and Spearing, S. M. (2005), “MEMS actuators and sensors: observations on their performance and selection for purpose”, Journal of Micromechanics and Micro engineering, Vol. 15, pp. S153–S164.
[7] Boser, B. E. (1996), “Capacitive Sensor Interfaces”, BSAC (Berkeley Sensor and Actuator Center), University of Berkeley.
[8] Denishev, K. H. and Petrova, M. R. (2007). “Accelerometer Design”, Electronics’ 2007, pp.159-164.
[9] Eddy, D. S. (1998), “Application of MEMS
VFSTR Journal of STEM Vol. 01, No. 01 (2015) xxxx-xxxx
35
technology in automotive sensors and actuators”, Proceedings of the IEEE, Vol. 86, pp. 1747–55.
[10] Elwenspoerk, M. (2001), “Mechanical Microsensors”, Springer Verlag.
[11] Feynman, R. P. (1992), “There’s Plenty of Room at the Bottom”, Journal of Microelectromechanical Systems, Vol. 1, No. 1, pp. 60–66.
[12] Frank, R. (2000), “Understanding Smart Sensors”, Artech House Inc.
[13] Gregory, T. A. K. and Petersen, K. E. (1998), “Bulk Micromachining Of Silicon”, Proceedings of the IEEE, Vol. 86, No. 8, pp. 1536-1551.
[14] Hsu, T. R. (2001), “MEMS and Microsystems: Design and Manufacture”, McGraw-Hill College.
[15] Hsu, T.R. (2002), “Miniaturization – A paradigm shift in advanced manufacturing and education”, IEEE/ASME International conference on Advanced Manufacturing Technologies and Education in the 21st Century, pp. 1-19.
[16] Judy, J. W. (2001), “Microelectromechanical Systems (MEMS): Fabrication, Design and Applications”, Smart Materials and Structures, Vol. 10, pp. 1115–1134.
[17] Kampen, V. R. P. and Wolffenbuttel, R. F. (1998), “Modeling the mechanical behavior of bulk-micromachined silicon accelerometers”, Sensors and Actuators ‘A’, Vol. 64, pp. 137-150.
[18] Kraft, F. and Szymkowiak, S. (1998), “A novel micromachined capacitive accelerometer interface”, Sensors and Actuators ‘A’, Vol.68, pp.466-473.
[19] Li, G. and Guoying Wu (2001), “Design and fabrication of a highly symmetrical capacitive triaxial accelerometer”, Journal of
Micromechanics and Microengineering, Vol. 11, pp. 48–54.
[20] Maluf N., K. Williams (2004), “An Introduction to Microelectromechanical Systems Engineering”, Artech House Inc.
[21] Muller S., A. Pisano (2000), “Microactuators”, CRC Pr I Llc.
[22] Nexus MST market analysis, http://www.nexus-mems.com.
[23] Petersen, K. E. (1982), “Silicon as a Mechanical Material”, Proceedings of the IEEE, Vol. 70, No. 5, May 1982.
[24] Rudolf, F. (1983), “A micromechanical capacitive accelerometer with a two-point inertial-mass suspension”, Sensors and Actuators, Vol. 4, pp. 191-198.
[25] Rudolf, F (1990), “Precision Accelerometers with μg Resolution”, Sensors and Actuators ‘A’, pp. 297-302.
[26] Sidek, O. and Kunhi, S. K. (2009), “Optimal Design of Capacitive Micro Cantilever Beam Accelerometer”, Modern Applied Science, Vol.3, pp.16-28.
[27] Spearing, S. M. (2000), “Materials Issues in Microelectromechanical Systems (MEMS)”, Acta Materialia, Vol. 48, pp. 179-196.
[28] Srikar, V. T. and Senturia, S. D. (2002), “The Reliability of Microelectromechanical Systems (MEMS) in Shock Environments”, Journal of Microelectromechanical Systems, Vol. 11, No. 3, pp. 206-214.
[29] Technical Paper 291, “Accelerometer Selection Based on Applications”, Endevco corporation, California, pp.1-8.
[30] Yazdi, N. and Najafi, K. (1999), “An Interface IC for a Capacitive Silicon μg Accelerometer”, IEEE International Solid-State Circuits Conference.