42
ENGINEERING INSTRUCTIONS INST. NO. EG060 REV. : 30 TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES DATE: 09/08/00 PAGE 1 OF 42 1.0 SCOPE: 1.1 TO PROVIDE A METHOD OF SELECTING "O" RINGS FOR VALVE SERIES 1900, 1970, 1990, 2900, 19000, 3900 & 4900 VALVE APPLICATIONS AND 8 DIGIT PART NUMBER REPLACEMENTS FOR 7 DIGIT PART NUMBERS. 1.2 REVISION TO THIS INSTRUCTION MAY REQUIRE A CORRESPONDING REVISION TO DRAWING 310 AND INSTRUCTION EG057. 2.0 "O" RING SELECTION FOR NEW VALVES: 2.1 MATERIAL SELECTION IS A FUNCTION OF VALVE SET PRESSURE, RELIEVING TEMPERATURE (FOR FIRE APPLICATIONS THE VALVE OPERATING TEMPERATURE IS USED) AND FLUID. 2.2 MATERIAL SELECTION IS ACCOMPLISHED AS FOLLOWS: 2.2.1 REFER TO TABLE 1. 2.2.1.1 FOR 2900, 3900 & 4900 SERIES MAIN VALVES, THE FOLLOWING MATERIALS ARE STANDARD: 2.2.1.2.1 STEAM SERVICE IS TEFLON. ONLY ALTERNATIVE IS EPR FOR TEMPERATURES UNDER 400E F AND PRESSURES BELOW 50 PSIG. 2.2.1.2.2 GAS, AIR, AND LIQUID SERVICE IS 70 DUROMETER NITRILE. 2.2.1.2.3 ONLY DEVIATE FROM STANDARD IF TEMPERATURE, PRESSURE, OR MEDIA REQUIRE IT. 2.2.1.2 LOCATE VALVE FLUID AND READ THE APPLICABLE O-RING MATERIALS. FOR FLUIDS NOT LISTED, THE CUSTOMER MUST SPECIFY THE O-RING MATERIAL.

ENGINEERING INSTRUCTIONS - Swan Associates IncCARBON TETRA-CHLORIDE X X X CARBONIC ACID X X X X X X ENGINEERING INSTRUCTIONS TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: ENGINEERING INSTRUCTIONS - Swan Associates IncCARBON TETRA-CHLORIDE X X X CARBONIC ACID X X X X X X ENGINEERING INSTRUCTIONS TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

ENGINEERING INSTRUCTIONS

INST. NO. EG060 REV. : 30 TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

DATE: 09/08/00 PAGE 1 OF 42

1.0 SCOPE:

1.1 TO PROVIDE A METHOD OF SELECTING "O" RINGS FOR VALVE SERIES 1900, 1970, 1990,2900, 19000, 3900 & 4900 VALVE APPLICATIONS AND 8 DIGIT PART NUMBER REPLACEMENTSFOR 7 DIGIT PART NUMBERS.

1.2 REVISION TO THIS INSTRUCTION MAY REQUIRE A CORRESPONDING REVISION TO DRAWING310 AND INSTRUCTION EG057.

2.0 "O" RING SELECTION FOR NEW VALVES:

2.1 MATERIAL SELECTION IS A FUNCTION OF VALVE SET PRESSURE, RELIEVINGTEMPERATURE (FOR FIRE APPLICATIONS THE VALVE OPERATING TEMPERATURE IS USED)AND FLUID.

2.2 MATERIAL SELECTION IS ACCOMPLISHED AS FOLLOWS:

2.2.1 REFER TO TABLE 1.

2.2.1.1 FOR 2900, 3900 & 4900 SERIES MAIN VALVES, THE FOLLOWINGMATERIALS ARE STANDARD:

2.2.1.2.1 STEAM SERVICE IS TEFLON. ONLY ALTERNATIVE IS EPRFOR TEMPERATURES UNDER 400EEF AND PRESSURESBELOW 50 PSIG.

2.2.1.2.2 GAS, AIR, AND LIQUID SERVICE IS 70 DUROMETER NITRILE.

2.2.1.2.3 ONLY DEVIATE FROM STANDARD IF TEMPERATURE,PRESSURE, OR MEDIA REQUIRE IT.

2.2.1.2 LOCATE VALVE FLUID AND READ THE APPLICABLE O-RING MATERIALS.FOR FLUIDS NOT LISTED, THE CUSTOMER MUST SPECIFY THE O-RINGMATERIAL.

Page 2: ENGINEERING INSTRUCTIONS - Swan Associates IncCARBON TETRA-CHLORIDE X X X CARBONIC ACID X X X X X X ENGINEERING INSTRUCTIONS TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

ENGINEERING INSTRUCTIONS

INST. NO. EG060 REV. : 30 TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

DATE: 09/08/00 PAGE 2 OF 42

2.2.2 REFER TO TABLE 2.

LOCATE THE VALVE TYPE AND SET PRESSURE AND READ THE "O" RING DUROMETER AND SIZE CODE.

2.2.3 REFER TO TABLE 3.

2.2.3.1 LOCATE THE MATERIAL AND DUROMETER AND READ THE MATERIALDESCRIPTION, TEMPERATURE LIMITS AND MATERIAL CODE.

2.2.3.2 CHECK THE TEMPERATURE LIMITS FOR THE SPECIFIED MATERIAL. REPEAT 2.2.3.1 FOR APPLICABLE MATERIALS IF TEMPERATURE LIMITSARE EXCEEDED. FOR SOME CONDITIONS OF FLUID, PRESSURE ANDTEMPERATURE "O" RINGS CANNOT BE OFFERED.

3.0 REPLACEMENT PARTS ORDER:

3.1 EFFECTIVE SEPTEMBER 1986, "O" RINGS FOR ALL SAFETY RELIEF VALVES HAVE BEENPLACED ON DRAWING NO. 310. THE MATERIAL DESCRIPTION AND CODES HAVE BEENCHANGED WHEN COMPARED TO DRAWING NO. 312 AND THE PREVIOUS DRAWING NO. 310. THE "O" RING SIZE CODE HAS BEEN CHANGED FROM THE DRESSER TWO DIGIT CODE TOSTANDARD AS568A (AEROSPACE STANDARD) THREE DIGIT CODE. "O" RING SIZES WHICHDO NOT CORRESPOND TO THIS STANDARD HAVE BEEN ASSIGNED A DRESSER TWO DIGITCODE WITH AN "S" PREFIX. EXAMPLE: S01 - SPECIAL "O" RING SIZE TO DRESSERDRAWING NO. 310. AN "N" SUFFIX AT THE END OF THE PART NUMBER INDICATES"NUCLEAR SERVICE" WITH CONTROLLED BATCH IDENTIFICATION (CBI) WITH PHYSICALS(HARDNESS, TENSILE, AND ELONGATION).

3.2 MATERIAL SELECTION

MATERIAL SELECTION MAY BE ACCOMPLISHED PER TABLE 4 OR PARAGRAPH 2.0.

3.3 SIZE SELECTION

THE THREE DIGIT REPLACEMENT SIZE CODE IS OBTAINED FROM TABLE

Page 3: ENGINEERING INSTRUCTIONS - Swan Associates IncCARBON TETRA-CHLORIDE X X X CARBONIC ACID X X X X X X ENGINEERING INSTRUCTIONS TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

ENGINEERING INSTRUCTIONS

INST. NO. EG060 REV. : 30 TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

DATE: 09/08/00 PAGE 3 OF 42

TABLE I - - - CONTINUED

FLUID NITRILE ETHYL.-PROP.

FLUORO-CARB.

NEOPRENE SILI-CONE

TEFLON

ACETALDEHYDE X X X

ACETAMIDE X X X X X X

ACETIC ACID X X

ACETIC ANHYDRIDE X X X X

ACETONE X X

ACETOPHENONE X X

ACETYL ACETONE X X

ACETYL CHLORIDE X X

ACETYLENE X X X X X X

ACETYLENE TETRABROMIDE X X X X

AIR X X X X X X

ALKAZENE X X

AMINES-MIXED X X X

AMMONIA, GAS X X X X X

LIQUID (ANHYDROUS) X X X X X

AMMONIUM HYDROXIDE X X X X X

AMYL ALCOHOL X X X X X

AMYL BORATE X X X X

Page 4: ENGINEERING INSTRUCTIONS - Swan Associates IncCARBON TETRA-CHLORIDE X X X CARBONIC ACID X X X X X X ENGINEERING INSTRUCTIONS TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

ENGINEERING INSTRUCTIONS

INST. NO. EG060 REV. : 30 TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

DATE: 09/08/00 PAGE 4 OF 42

TABLE I - - - CONTINUED

FLUID NITRILE ETHYL.-PROP.

FLUORO-CARB.

NEOPRENE SILI-CONE

TEFLON

AMYL CHLORIDE X X

AMYL CHLORO-NAPHTHALENE X X

AMYL NAPHTHALENE X X

ANHYDROUS AMMONIA X X X X X

ANHYDROUS HYDRAZINE X X X

ANILINE X X

ARGON X X X X X X

ASPHALT X X X X

ASTM OIL X X X

AUTOMATIC TRANSMISSIONFLUID X X X X

BEER X X X X X X

BEET SUGAR LIQUORS X X X X X X

BENZALDEHYDE X X X

BENZENE X X

BENZO-CHLORIDE X X X

BENZOIC ACID X X X

BENZOPHENONE X X X

BENZYL ALCOHOL X X X X X

BENZYL BENZOATE X X

Page 5: ENGINEERING INSTRUCTIONS - Swan Associates IncCARBON TETRA-CHLORIDE X X X CARBONIC ACID X X X X X X ENGINEERING INSTRUCTIONS TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

ENGINEERING INSTRUCTIONS

INST. NO. EG060 REV. : 30 TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

DATE: 09/08/00 PAGE 5 OF 42

TABLE I - - - CONTINUED

FLUID NITRILE ETHYL.-PROP.

FLUORO-CARB.

NEOPRENE SILI-CONE

TEFLON

BENZYL CHLORIDE X X

BLEACH LIQUOR X X X X X

BORIC ACID X X X X X X

BRAKE FLUID (NON-PETROLEUM) X X X

BROMINE X X

BROMOBENZENE X X

BROMOCHLORO-TRIFLUORO-ETHANE

X X X

BUNKER OIL X X X X

BUTADIENE (MONOMER) X X

BUTANE X X X X

BUTANE, 2,2-DIMETHYL2,3-

DIMETHYL

X

X

X

X

X

X

X

X

BUTANOL (BUTYL ALCOHOL) X X X X X X

1-BUTENE,2-ETHYL

X X X

N-BUTYL ACETATE X X

BUTYL ALCOHOL X X X X X X

BUTYL AMINE OR N-BUTYLAMINE

X X

N-BUTYL BENZOATE X X X

Page 6: ENGINEERING INSTRUCTIONS - Swan Associates IncCARBON TETRA-CHLORIDE X X X CARBONIC ACID X X X X X X ENGINEERING INSTRUCTIONS TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

ENGINEERING INSTRUCTIONS

INST. NO. EG060 REV. : 30 TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

DATE: 09/08/00 PAGE 6 OF 42

TABLE I - - - CONTINUED

FLUID NITRILE ETHYL.-PROP.

FLUORO-CARB.

NEOPRENE SILI-CONE

TEFLON

N-BUTYL BUTYRATE X X X

BUTYLENE X X X

BUTYRAL- DEHYDE X X

BUTYRIC ACID X X X

CALCIUM ACETATE X X X X

CALCIUM BISULFITE X X X X X

CALCIUM CARBONATE X X X X X X

CALCIUM CHLORIDE X X X X X X

CALCIUM CYANIDE X X X X X

CALCIUM HYDROXIDE X X X X X X

CALCIUM HYPOCHLORITE X X X X X X

CALCIUM NITRATE X X X X X X

CALCIUM PHOSPHATE X X X X X X

CANE SUGAR LIQUORS X X X X X X

CARBOLIC ACID PHENOL X X X

CARBON BISULFIDE X X X

CARBON DIOXIDE X X X X X X

CARBON DISULFIDE X X

CARBON MONOXIDE X X X X X X

CARBON TETRA-CHLORIDE X X X

CARBONIC ACID X X X X X X

Page 7: ENGINEERING INSTRUCTIONS - Swan Associates IncCARBON TETRA-CHLORIDE X X X CARBONIC ACID X X X X X X ENGINEERING INSTRUCTIONS TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

ENGINEERING INSTRUCTIONS

INST. NO. EG060 REV. : 30 TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

DATE: 09/08/00 PAGE 7 OF 42

TABLE I - - - CONTINUED

FLUID NITRILE ETHYL.-PROP.

FLUORO-CARB.

NEOPRENE SILI-CONE

TEFLON

CASTOR OIL X X X X X X

CETANE (HEXA-DECANE) X X X X

CHLORACETIC ACID X X

CHLORINATED SALT BRINE X X

CHLORINE, DRY X X X

CHLORINE DIOXIDE X X

CHLORO-ACETONE X X

CHLORO-BENZENE X X

CHLOROBROMO- METHANE X X X

CHLORO-BUTADIENE X X

CHLORO-DODECANE X X

CHLOROFORM X X

O-CHLORO-NAPHTHALENE X X

CHLORO-TOLUENE X X

CHLOROX X X X X X

O-CHLOR-PHENOL X X

CHROME PLAT-ING SOLUTIONS X X X X

CITRIC ACID X X X X X X

CORN OIL X X X X

COTTONSEED OIL X X X X X X

Page 8: ENGINEERING INSTRUCTIONS - Swan Associates IncCARBON TETRA-CHLORIDE X X X CARBONIC ACID X X X X X X ENGINEERING INSTRUCTIONS TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

ENGINEERING INSTRUCTIONS

INST. NO. EG060 REV. : 30 TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

DATE: 09/08/00 PAGE 8 OF 42

TABLE I - - - CONTINUED

FLUID NITRILE ETHYL.-PROP.

FLUORO-CARB.

NEOPRENE SILI-CONE

TEFLON

CRUDE OIL X X X

CYCLOHEXANE X X X

YCLOHEXANOL X X X X

CYCLO- HEXANONE X X

DECALIN X X

DECANE X X X X

DENATURED ALCOHOL X X X X X X

DETERGENT, WATER SOLUTIONX X X X X X

DEXRON X X X X

DIACETONE X X X

DIACETONE ALCOHOL X X X

DIBENZYL ETHER X X

DIBENZYL SEBACATE X X X

DIBROMOETHYL BENZENE X X

DIBUTYL PHTHALATE X X X

DIBUTYL SEBACATE X X X X

O-DICHLORO-BENZENE X X

P-DICHLORO-BENZENE X X

DICHLORO-BUTANE X X X

Page 9: ENGINEERING INSTRUCTIONS - Swan Associates IncCARBON TETRA-CHLORIDE X X X CARBONIC ACID X X X X X X ENGINEERING INSTRUCTIONS TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

ENGINEERING INSTRUCTIONS

INST. NO. EG060 REV. : 30 TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

DATE: 09/08/00 PAGE 9 OF 42

TABLE I - - - CONTINUED

FLUID NITRILE ETHYL.-PROP.

FLUORO-CARB.

NEOPRENE SILI-CONE

TEFLON

DIESEL OIL X X X

DI-ESTER SYNTHETICLUBRICANTS

X X X

DIETHYLAMINE X X X X

DIETHYL SEBACATE X X X X X

DIETHYLENE GLYCOL X X X X X X

DIISO-BUTYLENE X X X

DIISOPROPYL KETONE X X X X

DIMETHYL FORMAMIDE (DMF) X X X

DIMETHYL PHTHALATE X X X

DIOCTYL PHTHALATE X X X

DIOCTYL SEBACATE X X X

DIOXANE X X

DIOXOLANE X X

DIPENTENE X X X

DIPHENYL X X X X X X

DIPHENYL OXIDES X X X X X X

DOWTHERM, A , E X X

EPICHLORO-HYDRIN X X

Page 10: ENGINEERING INSTRUCTIONS - Swan Associates IncCARBON TETRA-CHLORIDE X X X CARBONIC ACID X X X X X X ENGINEERING INSTRUCTIONS TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

ENGINEERING INSTRUCTIONS

INST. NO. EG060 REV. : 30 TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

DATE: 09/08/00 PAGE 10 OF 42

TABLE I - - - CONTINUED

FLUID NITRILE ETHYL.-PROP.

FLUORO-CARB.

NEOPRENE SILI-CONE

TEFLON

ETHANE X X X X

ETHANOL X X X X

ETHANOL AMINE X X X X X

ETHYL ACETATE-ORGANICESTER

X X X

ETHYL ACETOACETATE X X X

ETHYL ACRYLATE X X X

ETHYL ALCOHOL X X X X X

ETHYL BENZENE X X

ETHYL BENZOATE X X

ETHYL BROMIDE X X X

ETHYL CELLOSOLVE X X

ETHYL CELLULOSE X X X X X

ETHYL CHLORIDE X X X

ETHYL CHLORO-CARBONATE X X X

ETHYL CHLORO-FORMATE X X

ETHYLCYCLO-PENTANE X X X

ETHYLENE CHLORIDE X X

ETHYLENE CHLOROHYDRIN X X X X

Page 11: ENGINEERING INSTRUCTIONS - Swan Associates IncCARBON TETRA-CHLORIDE X X X CARBONIC ACID X X X X X X ENGINEERING INSTRUCTIONS TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

ENGINEERING INSTRUCTIONS

INST. NO. EG060 REV. : 30 TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

DATE: 09/08/00 PAGE 11 OF 42

TABLE I - - - CONTINUED

FLUID NITRILE ETHYL.-PROP.

FLUORO-CARB.

NEOPRENE SILI-CONE

TEFLON

ETHYLENE DIAMINE X X X X X

ETHYLENE DIBROMIDE X X

ETHYLENE DICHLORIDE X X

ETHYL FORMATE X X X X

ETHYLENE GLYCOL X X X X X X

ETHYLENE TRICHLORIDE X X

ETHYL HEXANOL X X X X X X

ETHYL MERCAPTAN X X

ETHYL OXALATE X X X

ETHYL PENTACHLORO-BENZENE X X

ETHYL SILICATE X X X X X

FATTY ACIDS X X X X

FERRIC CHLORIDE X X X X X X

FERRIC NITRATE X X X X X X

FORMALDEHYDE X X X

FREON,11 12 13 13B1

XXXX

XX

XXXX

XXX

XXXX

Page 12: ENGINEERING INSTRUCTIONS - Swan Associates IncCARBON TETRA-CHLORIDE X X X CARBONIC ACID X X X X X X ENGINEERING INSTRUCTIONS TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

ENGINEERING INSTRUCTIONS

INST. NO. EG060 REV. : 30 TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

DATE: 09/08/00 PAGE 12 OF 42

TABLE I - - - CONTINUED

FLUID NITRILE ETHYL.-PROP.

FLUORO-CARB.

NEOPRENE SILI-CONE

TEFLON

FREON,14 22 31 32

XX

XX

X XXXX

XXXX

FREON,112 113 114FUEL OIL ACIDIC #6

XXXXXX

X XXXXXX

XXXXX X

X

XXXXXX

FUMARIC ACID X X X X X X

FURFURAL X X

FURFURAL-DEHYDE X X

FUFURYL ALCOHOL X X

FUFURYL CARBINOL X X

GALLIC ACID X X X X X

GASOLINE X X X X

GELATIN X X X X X X

GLUCOSE X X X X X X

GLYCERINE-GLYCEROL X X X X X X

GLYCOLS X X X X X

HALOTHANE X X

Page 13: ENGINEERING INSTRUCTIONS - Swan Associates IncCARBON TETRA-CHLORIDE X X X CARBONIC ACID X X X X X X ENGINEERING INSTRUCTIONS TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

ENGINEERING INSTRUCTIONS

INST. NO. EG060 REV. : 30 TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

DATE: 09/08/00 PAGE 13 OF 42

TABLE I - - - CONTINUED

FLUID NITRILE ETHYL.-PROP.

FLUORO-CARB.

NEOPRENE SILI-CONE

TEFLON

HALOWAX OIL X X

HELIUM X X X X X X

N-HEPTANE X X X X

N-HEXALDEHYDE X X X X

N-HEXANE X X X X

N-HEXANE-1 X X X X

HEXYL ALCOHOL X X X X

HYDRAULIC OIL, PETROLEUMBASE X X X X X

HYDRAZINE X X X X X

HYDROBROMIC ACID X X X

HYDROCARBONS X X X X

HYDROCHLORIC ACID, TO 158EEFX X X X X

HYDROCYANIC ACID X X X X X

HYDROFLUO-SILIC ACID X X X X X

HYDROGEN GAS X X X X X

HYDROGEN PEROXIDE (1) X X

HYDROGEN SULFIDE X X X

Page 14: ENGINEERING INSTRUCTIONS - Swan Associates IncCARBON TETRA-CHLORIDE X X X CARBONIC ACID X X X X X X ENGINEERING INSTRUCTIONS TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

ENGINEERING INSTRUCTIONS

INST. NO. EG060 REV. : 30 TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

DATE: 09/08/00 PAGE 14 OF 42

TABLE I - - - CONTINUED

FLUID NITRILE ETHYL.-PROP.

FLUORO-CARB.

NEOPRENE SILI-CONE

TEFLON

HYDYNE X X X X

HYPOCHLOROUS ACID X X X X

IODINE X X X X X

ISOBUTYL ALCOHOL X X X X X X

ISO-BUTYL N-BUTYRATE X X X

ISODODECANE X X X X

ISO OCTANE X X X X

ISOPHORONE (KETONE) X X

ISOPROPANOL X X X X X X

ISOPROPYL ACETATE X X

ISOPROPYL ALCOHOL X X X X X X

ISOPROPYL CHLORIDE X X

ISOPROPYL ETHER X X

JP-3 TO JP-10 X X

KEROSENE X X X X

LACTIC ACID X X

LACTONES X X

LINOLEIC ACID X X X X X

LINSEED OIL X X X X

LIQUID PETROLEUM GAS (LPG) X X X X

Page 15: ENGINEERING INSTRUCTIONS - Swan Associates IncCARBON TETRA-CHLORIDE X X X CARBONIC ACID X X X X X X ENGINEERING INSTRUCTIONS TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

ENGINEERING INSTRUCTIONS

INST. NO. EG060 REV. : 30 TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

DATE: 09/08/00 PAGE 15 OF 42

TABLE I - - - CONTINUED

FLUID NITRILE ETHYL.-PROP.

FLUORO-CARB.

NEOPRENE SILI-CONE

TEFLON

LUBRICATING OILS X X X

LYE SOLUTIONS X X X X X X

MAGNESIUM HYDROXIDE X X X X X

MALATHION X X X

MALEIC ACID X X

MALEIC ANHYDRIDE X X

MALIC ACID X X X X X X

MESITYL OXIDE (KETONE) X X

METHANE X X X X

METHANOL X X X X

METHYL ACETATE X X X

METHYL ACETOACETATE X X X

METHYL ACRYLATE X X X

METHYL-ACRYLIC ACID X X X

METHYL ALCOHOL X X X X X

METHYL BENZOATE X X

METHYL BROMIDE X X X

METHYL BUTYL KETONE X X

METHYL CARBONATE X X

METHYL CHLORIDE X X

METHYL CHLORO-FORMATE X X

Page 16: ENGINEERING INSTRUCTIONS - Swan Associates IncCARBON TETRA-CHLORIDE X X X CARBONIC ACID X X X X X X ENGINEERING INSTRUCTIONS TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

ENGINEERING INSTRUCTIONS

INST. NO. EG060 REV. : 30 TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

DATE: 09/08/00 PAGE 16 OF 42

TABLE I - - - CONTINUED

FLUID NITRILE ETHYL.-PROP.

FLUORO-CARB.

NEOPRENE SILI-CONE

TEFLON

METHYLCYCLO-PENTANE X X

METHYLENE CHLORIDE X X

METHYL ETHER X X X X

METHYL ETHYL KETONE (MEK) X X

METHYL FORMATE X X X

METHYL ISOPROPYL KETONE X X

METHYL MERCAPTAN X X

N-METHYL-2-PYRROLIDONE X X

METHYL OLEATE X X

METHYL SALICYLATE X X

MILK X X X X X X

MINERAL OILS X X X X X

MONO BROMOBENZENE X X X

MONOCHLORO-BENZENE X X

MONO ETHANOLAMINE X X X

MONOMETHYL-ANILINE X X X X

MONOMETHYL HYDRAZINE X X X X

MONOVINYL ACETYLENE X X X X X X

NAPHTHA X X X

NAPHTHALENE X X

NAPHTHENIC ACID X X X

Page 17: ENGINEERING INSTRUCTIONS - Swan Associates IncCARBON TETRA-CHLORIDE X X X CARBONIC ACID X X X X X X ENGINEERING INSTRUCTIONS TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

ENGINEERING INSTRUCTIONS

INST. NO. EG060 REV. : 30 TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

DATE: 09/08/00 PAGE 17 OF 42

TABLE I - - - CONTINUED

FLUID NITRILE ETHYL.-PROP.

FLUORO-CARB.

NEOPRENE SILI-CONE

TEFLON

NATURAL GAS X X X X

NEON X X X X X X

NICKEL ACETATE X X X X

NICKEL CHLORIDE X X X X X X

NICKEL SALTS X X X X X X

NICKEL SULFATE X X X X X X

NITROBENZENE X X X

NITROETHANE X X X

NITROGEN X X X X X X

NITROMETHANE X X

NITROPROPANE X X

NITROUS OXIDE X X

OCTADECANE X X X X

N-OCTANE X X X

OCTYL ALCOHOL X X X X X

OLEIC ACID X X

OLIVE OIL X X X X X

ORTHOCHLOROETHYLBENZENE

X X

Page 18: ENGINEERING INSTRUCTIONS - Swan Associates IncCARBON TETRA-CHLORIDE X X X CARBONIC ACID X X X X X X ENGINEERING INSTRUCTIONS TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

ENGINEERING INSTRUCTIONS

INST. NO. EG060 REV. : 30 TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

DATE: 09/08/00 PAGE 18 OF 42

TABLE I - - - CONTINUED

FLUID NITRILE ETHYL.-PROP.

FLUORO-CARB.

NEOPRENE SILI-CONE

TEFLON

ORTHO-DICHLORO-BENZENE X X

OXALIC ACID X X X X X X

OXYGEN X X X X X X

PALMITIC ACID X X X X X

PARA-DICHLORO-BENZENE X X

PEANUT OIL X X X X X X

PENTANE X X X X

N-PENTANE X X X X

PERCHLORO-ETHYLENE X X X

PETROLATUM X X X X

PETROLEUM OIL X X X

PHENOL X X

PHENYL-BENZENE X X

PHENYL-HYDRAZINE X X X

PHOSPHORIC ACID TO 158EEF X X X

PHOSPHOROUS TRICHLORIDE X X X

PINENE X X X

PINE OIL X X X

PLATING SOLUTIONS X X X

Page 19: ENGINEERING INSTRUCTIONS - Swan Associates IncCARBON TETRA-CHLORIDE X X X CARBONIC ACID X X X X X X ENGINEERING INSTRUCTIONS TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

ENGINEERING INSTRUCTIONS

INST. NO. EG060 REV. : 30 TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

DATE: 09/08/00 PAGE 19 OF 42

TABLE I - - - CONTINUED

FLUID NITRILE ETHYL.-PROP.

FLUORO-CARB.

NEOPRENE SILI-CONE

TEFLON

POTASSIUM ACETATE X X X X

POTASSIUM CHLORIDE X X X X X X

POTASSIUM CUPRO CYANIDE X X X X X X

POTASSIUM CYANIDE X X X X X X

POTASSIUM DICHROMATE X X X X X X

POTASSIUM NITRATE X X X X X X

POTASSIUM SALTS X X X X X X

POTASSIUM SULPHATE X X X X X X

POTASSIUM SULPHITE X X X X X X

PROPANE X X X X

PROPANE PROPIO-NITRILE X X X X

PROPYL ACETATE X X X

N-PROPYL ACETONE X X

PROPYL ALCOHOL X X X X X X

PROPYLENE X X

PROPYLENE OXIDE X X

PROPYL NITRATE X X X

RAPESEEO OIL X X X X X

SALICYLIC ACID X X X X X X

SEA (SALT) WATER X X X X X X

Page 20: ENGINEERING INSTRUCTIONS - Swan Associates IncCARBON TETRA-CHLORIDE X X X CARBONIC ACID X X X X X X ENGINEERING INSTRUCTIONS TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

ENGINEERING INSTRUCTIONS

INST. NO. EG060 REV. : 30 TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

DATE: 09/08/00 PAGE 20 OF 42

TABLE I - - - CONTINUED

FLUID NITRILE ETHYL.-PROP.

FLUORO-CARB.

NEOPRENE SILI-CONE

TEFLON

SILICONE OILS X X X X X

SILVER NITRATE X X X X X X

SOAP SOLUTIONS X X X X X X

SODIUM ACETATE X X X X

SODIUM BICARBONATE X X X X X X

SODIUM BORATE X X X X X X

SODIUM CARBONATE X X X X X X

SODIUM BISULFATE ORBISULFITE X X X X X X

SODIUM CHLORIDE X X X X X X

SODIUM CYANIDE X X X X X

SODIUM HYDROXIDE,3 MOLAR X X X X X X

SODIUM HYPOCHLORITE X X X X X X

SODIUM METAPHOS-PHATE X X X X X

SODIUM NITRATE X X X X

SODIUM PERBORATE X X X X X X

SODIUM PEROXIDE X X X X X

SODIUM PHOSPHATE X X X X X

SODIUM SILICATE X X X X X

Page 21: ENGINEERING INSTRUCTIONS - Swan Associates IncCARBON TETRA-CHLORIDE X X X CARBONIC ACID X X X X X X ENGINEERING INSTRUCTIONS TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

ENGINEERING INSTRUCTIONS

INST. NO. EG060 REV. : 30 TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

DATE: 09/08/00 PAGE 21 OF 42

TABLE I - - - CONTINUED

FLUID NITRILE ETHYL.-PROP.

FLUORO-CARB.

NEOPRENE SILI-CONE

TEFLON

SODIUM SULPHATE X X X X X X

SODIUM SULPHIDE AND SULFITEX X X X X X

SODIUM THIOSULFATE X X X X X X

SOYBEAN OIL X X X X X X

STANNIC CHLORIDE X X X X X

STEAM X X

STEARIC ACID X X X X X

STODDARD SOLVENT X X X X

STYRENE X X

SUCROSE SOLUTIONS X X X X X X

SULFUR X X X

SULFUR CHLORIDE X X

SULFUR DIOXIDE X X X

SULFURIC ACID TO 158°°F X X X X X X

SULFUROUS ACID X X X X X

SULFUR TRIOXIDE, DRY X X X X X

TAR, BITUMINOUS X X X X X X

TARTARIC ACID X X X X X X

Page 22: ENGINEERING INSTRUCTIONS - Swan Associates IncCARBON TETRA-CHLORIDE X X X CARBONIC ACID X X X X X X ENGINEERING INSTRUCTIONS TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

ENGINEERING INSTRUCTIONS

INST. NO. EG060 REV. : 30 TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

DATE: 09/08/00 PAGE 22 OF 42

TABLE I - - - CONTINUED

FLUID NITRILE ETHYL.-PROP.

FLUORO-CARB.

NEOPRENE SILI-CONE

TEFLON

TERPINEOL X X X

TERTIARY BUTYL ALCOHOL X X X X X X

P-TERTIARY BUTYL CATECHOL X X X X

TERTIARY BUTYL MERCAPTAN X X

TETRABROMO-ETHANE X X

TETRABUTYL TITANATE X X X X X

TETRACHORO-ETHANE X X

TETRACHLORO- ETHYLENE X X

TETRAHYDRO-FURAN X X

TETRALIN X X

THERMINOL VP-1, 44, 55, 60, 66 X X

TOLUENE X X

TOLUENE DIISOCYANATE X X

TRIACETIN X X X X

TRIARYL PHOSPHATE X X X

TRIBUTOXY-ETHYL PHOSPHATE X X X

TRIBUTYL MERCAPTAN X X

TRIBUTYL PHOSPHATE X X

Page 23: ENGINEERING INSTRUCTIONS - Swan Associates IncCARBON TETRA-CHLORIDE X X X CARBONIC ACID X X X X X X ENGINEERING INSTRUCTIONS TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

ENGINEERING INSTRUCTIONS

INST. NO. EG060 REV. : 30 TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

DATE: 09/08/00 PAGE 23 OF 42

TABLE I

FLUID NITRILE ETHYL.-PROP.

FLUORO-CARB.

NEOPRENE SILI-CONE

TEFLON

TRICHLORO-ACETIC ACID X X X

TRICHLORO-ETHANE X X

TRICHLORO-ETHYLENE X X

TRICRESYL PHOSPHATE X X X

TRIETHANOL AMINE X X X

TRIFLUORO-ETHANE X X

TRIOCTYL PHOSPHATE X X X

TRIPOLY PHOSPHATE X X X

TUNG OIL (CHINA WOOD OIL) X X X X

TURPENTINE X X X

VARNISH X X X

VEGETABLE OIL X X X

VINEGAR X X X X

WATER X X X X X X

WHISKEY AND WINES X X X X X X

XYLENE X X

XYLOL X X

XENON X X X X X X

ZINC ACETATE X X X X

ZINC CHLORIDE X X X X X

ZINC SALTS X X X X X X

ZINC SULFATE X X X X X X

Page 24: ENGINEERING INSTRUCTIONS - Swan Associates IncCARBON TETRA-CHLORIDE X X X CARBONIC ACID X X X X X X ENGINEERING INSTRUCTIONS TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

ENGINEERING INSTRUCTIONS

INST. NO. EG060 REV. : 30 TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

DATE: 09/08/00 PAGE 24 OF 42

TABLE II - - - SET PRESSURE RANGE "O" RING DUROMETER

TEFLONVALVE TYPE

(1)50

(1)70 TO 75 90

-300 TO 200 °°F 201 TO 500°°F

SIZECODE

1900D-1 5-350 100-800 200-2000 2000-6000 285-6000 112

E-1 5-350 140-800 315-2000 2000-6000 285-6000 114

D&E-2,F 5-350 120-800 265-2000 2000-6000 285-6000 116

G 5-375 125-780 375-1900 1900-3705 285-3705 212

H 5-375 140-780 330-1900 1900-2750 285-2750 215

J 5-315 45-780 150-1900 1900-2700 250-2700 220

K 5-235 125-580 255-1400 1400-2220 250-2220 326

L 5-235 75-580 155-1400 1400-1500 155-1500 329

M 5-235 70-580 140-1100 --------- 140-1100 332

N 5-235 40-580 90-1000 --------- 90-1000 333

P 5-200 30-500 75-1000 --------- 75-1000 338

Q 5-170 40-420 80- 600 --------- 80- 600 346

R 5-120 25-300 60- 300 --------- 60- 300 428

T 5- 80 15-200 30- 300 --------- 30- 300 437

T-4 5-80 15-200 30-300 --------- 30-300 438

V --- 15-300 15-300 --------- 15-300 447

W --- 7-300 7-300 --------- 15-300 451

Page 25: ENGINEERING INSTRUCTIONS - Swan Associates IncCARBON TETRA-CHLORIDE X X X CARBONIC ACID X X X X X X ENGINEERING INSTRUCTIONS TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

ENGINEERING INSTRUCTIONS

INST. NO. EG060 REV. : 30 TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

DATE: 09/08/00 PAGE 25 OF 42

TABLE II - - - CONTINUED

TEFLONVALVE TYPE

(1)50

(1)70 TO 75 90

-300 TO 200 °°F 201 TO 500°°F

SIZECODE

1990-2 --- --- 1401-2000 1401-2000 1401-2000 109

1990-1, 1991, 94,95

5-360 175-550 360-1400 1400-5000 360-5000 012

1992 5-250 120-580 250-1400 1400-2500 250-2500 014

1993,96 5-160 40-400 100-1000 1000-1500 100-1500 114

1994H 5-160 40-400 100-1000 1000-6000 100-6000 110

1996H 5-160 40-400 100-1000 1000-6000 100-6000 112

1997 5-230 75-580 155-1500 - - - - - - - 155-1500 116

1998 5-150 30-375 65- 800 - - - - - - - 65- 800 119

1975 5-360 175-550 360-1400 1400-2000 360-2000 110

3/4-1 - 1970 5-160 40-400 100-1000 1000-5000 100-5000 113

1 1/2 - 2 - 1970 5-150 30-375 65-1000 1000-1500 65-1500 118

*19096/19110 5-300 100-500 300-2500 1400-5000 15-5000 013

19126 5-250 30-500 250-2250 1000-6000 15-6000 014

19226 5-200 15-450 200-2000 1000-6000 15-6000 017

19357 5-150 15-400 150-1500 - - - - - - - 15-1500 118

19567 5-150 15-400 100-1000 - - - - - - - 15-1000 121

*19096M-BP ORINGS FOR SPINDLE AND BACKING RING (310XX011 AND 310XX030) SHALL BE THE SAME

MATERIAL AND DUROMETER, AS REQUIRED FOR ORING SEAT MATERIAL.

Page 26: ENGINEERING INSTRUCTIONS - Swan Associates IncCARBON TETRA-CHLORIDE X X X CARBONIC ACID X X X X X X ENGINEERING INSTRUCTIONS TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

ENGINEERING INSTRUCTIONS

INST. NO. EG060 REV. : 30 TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

DATE: 09/08/00 PAGE 26 OF 42

TABLE I I - - - CONTINUED

TEFLON 0B4

31

0B4

36

0B4

36VALVE

TYPE

(1)

50

(1)

70 TO 75

90

-300 TO

200°°F

201 TO

505°°F

(2)

SIZE

CODE

SEAT

(2,3)

SIZE

CODE

PISTON

O-RING

(3)

SIZE

CODE

PISTON

ENERGIZE

SEAL

2900 D, E,F N/A 15-800 265-2000 2000-3750 50-3750 116 020 4848122

G N/A 15-780 375-1900 1900-3705 50-3705 212 022 4848123

H N/A 15-780 330-1900 1900-2750 50-2750 215 026 4848124

J N/A 15-780 150-1900 1900-2700 50-2700 220 029 4848127

K N/A 15-580 255-1400 1400-2220 50-2220 326 032 4848128

L N/A 15-580 155-1400 1400-1500 50-1500 329 036 4848129

M N/A 15-580 140-1100 - - - - - - - - 50-1100 332 147 4848130

N N/A 15-580 90-1000 - - - - - - - - 50-1000 333 150 4848131

P N/A 15-500 75-1000 - - - - - - - - 50-1000 338 238 4848132

NOTES: (1) MAXIMUM SET PRESSURE FOR SILICONE COMPOUNDS IS 22 OF THE MAXIMUM VALUE.

(2) WHEN MAIN VALVE IS EQUIPPED WITH O-RING SEAT, O-RINGS FOR SEAT AND PISTON SHALL

BE OF THE SAME MATERIAL AND DUROMETER.

(3) WHEN TEFLON MATERIAL IS SELECTED, PISTON SHALL BE EQUIPPED WITH A TEFLON

ENERGIZED SEAL INSTEAD OF AN O-RING.

(4) ON APPLICATION.

Page 27: ENGINEERING INSTRUCTIONS - Swan Associates IncCARBON TETRA-CHLORIDE X X X CARBONIC ACID X X X X X X ENGINEERING INSTRUCTIONS TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

ENGINEERING INSTRUCTIONS

INST. NO. EG060 REV. : 30 TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

DATE: 09/08/00 PAGE 27 OF 42

TABLE I I - - - CONTINUED

TEFLON 0B4

31

0B4

36

0B4

36VALVE

TYPE

(1)

50

(1)

70 TO 75

90

-300 TO

200°°F

201 TO

505°°F

(2)

SIZE

CODE

SEAT

(2,3)

SIZE

CODE

PISTON

O-RING

(3)

SIZE

CODE

PISTON

ENERGIZE

SEAL

Q N/A 15-420 80-600 - - - - - - - - 50-600 346 247 4848125

R N/A 15-300 60-300 - - - - - - - 50-300 428 253 4848133

T N/A 15-200 30-300 - - - - - - - - 50-300 438 262 4848134

V N/A 15-300 15-300 - - - - - - 50-300 447 (4) (4)

W N/A 15-300 15-300 - - - - - - - 50-300 451 (4) (4)

NOTES: (1) MAXIMUM SET PRESSURE FOR SILICONE COMPOUNDS IS 22 OF THE MAXIMUM VALUE.

(3) WHEN MAIN VALVE IS EQUIPPED WITH O-RING SEAT, O-RINGS FOR SEAT AND PISTON SHALL

BE OF THE SAME MATERIAL AND DUROMETER.

(3) WHEN TEFLON MATERIAL IS SELECTED, PISTON SHALL BE EQUIPPED WITH A TEFLON

ENERGIZED SEAL INSTEAD OF AN O-RING.

(4) ON APPLICATION.

Page 28: ENGINEERING INSTRUCTIONS - Swan Associates IncCARBON TETRA-CHLORIDE X X X CARBONIC ACID X X X X X X ENGINEERING INSTRUCTIONS TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

ENGINEERING INSTRUCTIONS

INST. NO. EG060 REV. : 30 TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

DATE: 09/08/00 PAGE 28 OF 42

TEFLON

VALVE TYPE

(1)

50

(1)

70 TO 75 90-300 TO 200 °°F 201 TO 500°°F

SIZE

CODE

19096/19110 PF 15-300 100-300 --------- -------- 15-300 013

19126 PF 15-250 30-300 250-300 -------- 15-300 014

19226 PF 15-200 15-300 200-300 -------- 15-300 017

19357 PF 15-150 15-300 150-300 -------- 15-300 118

19567 PF 15-150 15-300 100-300 --------- 15-300 121

Page 29: ENGINEERING INSTRUCTIONS - Swan Associates IncCARBON TETRA-CHLORIDE X X X CARBONIC ACID X X X X X X ENGINEERING INSTRUCTIONS TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

ENGINEERING INSTRUCTIONS

INST. NO. EG060 REV. : 30 TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

DATE: 09/08/00 PAGE 29 OF 42

TABLE I I - - - CONTINUED

TEFLON 0B4

31

0B4

36

VALVE TYPE (1)

50

(1)

70 TO 75

90-300 TO

200°°F

201 TO

505°°F

SIZE

CODE

SEAT

SIZE

CODE

DISC

ENERGIZE

SEAL

3900-3

1" D,E,F

N/A 15-800 200-1500 1000-3750 50-3750 213 4848113

1-1/2" D, E, F NA 15-800 200-1500 1000-3750 50-3750 213 4848113

1-1/2" G, H NA 15-780 150-1500 1000-3750 50-3750 326 4848114

2" G, H, J NA 15-780 150-1500 1000-3750 50-3750 326 4848114

3" J, K, L NA 15-580 150-1500 1000-3750 50-3750 331 4848115

4" L, M, N, P NA 15-580 75-1500 1000-3750 50-3750 339 4848105

6" Q, R NA 15-420 60-600 600-1500 50-1500 432 4848104

8" T NA 15-200 30-300 300-1500 50-1500 438 4848107

3" XFB NA 15-580 75-1500 1000-1500 50-1500 339 4848105

4" XFB NA 15-580 75-1500 1000-1500 50-1500 344 4848120

6" XFB NA 15-200 30-300 300-1500 50-1500 438 4848107

8" XFB NA 15-200 30-300 300-1500 50-1500 444 4848108

10" XFB NA 15-200 30-300 300-750 50-750 449 4848106

NOTES: (1) MAXIMUM SET PRESSURE FOR SILICONE COMPOUNDS IS 22 OF THE MAXIMUM VALUE.

Page 30: ENGINEERING INSTRUCTIONS - Swan Associates IncCARBON TETRA-CHLORIDE X X X CARBONIC ACID X X X X X X ENGINEERING INSTRUCTIONS TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

ENGINEERING INSTRUCTIONS

INST. NO. EG060 REV. : 30 TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

DATE: 09/08/00 PAGE 30 OF 42

TABLE II - - - CONTINUED

0B4 0B4 0B4TEFLON

31 36 36VALVE TYPE (1)

50

(1)

70 TO 75

90

-300 TO –

200EEF

-201 TO –

505EEF

(2)

SIZE

CODE

SEAT

(2, 3)

SIZE

CODE

DISC O-

RING

(3)

SIZE CODE

DISC

ENERGIZE

SEAL

3900-4

1" D,E,F

N/A 15-800 200-1500 1000-3750 50-3750 213 023 4848113

1-1/2" D, E, F NA 15-800 200-1500 1000-3750 50-3750 213 023 4848113

1-1/2" G, H NA 15-780 150-1500 1000-3750 50-3750 326 032 4848114

2" G, H, J NA 15-780 150-1500 1000-3750 50-3750 326 032 4848114

3" J, K, L NA 15-580 150-1500 1000-3750 50-3750 331 145 4848115

4" L, M, N, P NA 15-580 75-1500 1000-3750 50-3750 339 240 4848105

6" Q, R NA 15-420 60-600 600-1500 50-1500 432 361 4848104

8" T NA 15-200 30-300 300-1500 50-1500 438 365 4848107

NOTES: (1) MAXIMUM SET PRESSURE FOR SILICONE COMPOUNDS IS 22 OF THE MAXIMUM VALUE.

(2) O-RING SEAT AND DISC SHALL BE OF THE SAME MATERIAL AND DUROMETER.

(3) WHEN TEFLON MATERIAL IS SELECTED, DISC SHALL BE EQUIPPED WITH A TEFLON

ENERGIZED SEAL INSTEAD OF AN O-RING.

Page 31: ENGINEERING INSTRUCTIONS - Swan Associates IncCARBON TETRA-CHLORIDE X X X CARBONIC ACID X X X X X X ENGINEERING INSTRUCTIONS TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

ENGINEERING INSTRUCTIONS

INST. NO. EG060 REV. : 30 TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

DATE: 09/08/00 PAGE 31 OF 42

TABLE II - - - CONTINUED

0B4 0B4 0B4TEFLON

31 36 36VALVE TYPE (1)

50

(1)

70 TO 75

90

-300 TO –

200EEF

-201 TO –

505EEF

(2)

SIZE

CODE

SEAT

(2, 3)

SIZE

CODE

DISC O-

RING

(3)

SIZE CODE

DISC

ENERGIZE

SEAL

3" XFB NA 15-580 75-1500 1000-1500 50-1500 339 240 4848105

4" XFB NA 15-580 75-1500 1000-1500 50-1500 344 246 4848120

6" XFB NA 15-200 30-300 300-1500 50-1500 438 365 4848107

8" XFB NA 15-200 30-300 300-1500 50-1500 444 371 4848108

10" XFB NA 15-200 30-300 300-750 50-750 449 451 4848106

NOTES: (1) MAXIMUM SET PRESSURE FOR SILICONE COMPOUNDS IS 22 OF THE MAXIMUM VALUE.

(2) O-RING SEAT AND DISC SHALL BE OF THE SAME MATERIAL AND DUROMETER.

(3) WHEN TEFLON MATERIAL IS SELECTED, DISC SHALL BE EQUIPPED WITH A TEFLON

ENERGIZED SEAL INSTEAD OF AN O-RING.

Page 32: ENGINEERING INSTRUCTIONS - Swan Associates IncCARBON TETRA-CHLORIDE X X X CARBONIC ACID X X X X X X ENGINEERING INSTRUCTIONS TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

ENGINEERING INSTRUCTIONS

INST. NO. EG060 REV. : 30 TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

DATE: 09/08/00 PAGE 32 OF 42

TABLE II - - - CONTINUED

TEFLON 0B4

31

0B4

36

0B4

36

VALVE TYPE (1)

50

(1)

70 TO 75

90-300 TO

200°°F

201 TO

505°°F

(2)

SIZE

CODE

SEAT

(2,3)

SIZE

CODE

DISC

O-RING

(3)

SIZE

CODE

DISC

ENERGIZE

SEAL

4900-4

1" D,E,F

N/A 15-800 200-1500 1000-3750 50-3750 213 023 4848113

1-1/2" D, E, F NA 15-800 200-1500 1000-3750 50-3750 213 023 4848113

1-1/2" G, H NA 15-780 150-1500 1000-3750 50-3750 326 032 4848114

2" G, H, J NA 15-780 150-1500 1000-3750 50-3750 326 032 4848114

3" J, K, L NA 15-580 150-1500 1000-3750 50-3750 331 145 4848115

4" L, M, N, P NA 15-580 75-1500 1000-3750 50-3750 339 240 4848105

6" Q, R NA 15-420 60-600 600-1500 50-1500 432 361 4848104

8" T NA 15-200 30-300 300-1500 50-1500 438 365 4848107

NOTES: (1) MAXIMUM SET PRESSURE FOR SILICONE COMPOUNDS IS 22 OF THE MAXIMUM VALUE.

(2) O-RING SEAT AND DISC SHALL BE OF THE SAME MATERIAL AND DUROMETER.

(3) WHEN TEFLON MATERIAL IS SELECTED, DISC SHALL BE EQUIPPED WITH A TEFLON

ENERGIZED SEAL INSTEAD OF AN O-RING.

Page 33: ENGINEERING INSTRUCTIONS - Swan Associates IncCARBON TETRA-CHLORIDE X X X CARBONIC ACID X X X X X X ENGINEERING INSTRUCTIONS TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

ENGINEERING INSTRUCTIONS

INST. NO. EG060 REV. : 30 TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

DATE: 09/08/00 PAGE 33 OF 42

TABLE II - - - CONTINUED

TEFLON 0B4

31

0B4

36

0B4

36

VALVE TYPE (1)

50

(1)

70 TO 75

90-300 TO

200°°F

201 TO

505°°F

(2)

SIZE

CODE

SEAT

(2,3)

SIZE

CODE

DISC

O-RING

(3)

SIZE

CODE

DISC

ENERGIZE

SEAL

3" XFB NA 15-580 75-1500 1000-1500 50-1500 339 240 4848105

4" XFB NA 15-580 75-1500 1000-1500 50-1500 344 246 4848120

6" XFB NA 15-200 30-300 300-1500 50-1500 438 365 4848107

8" XFB NA 15-200 30-300 300-1500 50-1500 444 371 4848108

10" XFB NA 15-200 30-300 300-750 50-750 449 451 4848106

NOTES: (1) MAXIMUM SET PRESSURE FOR SILICONE COMPOUNDS IS 22 OF THE MAXIMUM VALUE.

(2) O-RING SEAT AND DISC SHALL BE OF THE SAME MATERIAL AND DUROMETER.

(3) WHEN TEFLON MATERIAL IS SELECTED, DISC SHALL BE EQUIPPED WITH A TEFLON

ENERGIZED SEAL INSTEAD OF AN O-RING.

Page 34: ENGINEERING INSTRUCTIONS - Swan Associates IncCARBON TETRA-CHLORIDE X X X CARBONIC ACID X X X X X X ENGINEERING INSTRUCTIONS TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

ENGINEERING INSTRUCTIONS

INST. NO. EG060 REV. : 30 TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

DATE: 09/08/00 PAGE 34 OF 42

TABLE III - - - CONTINUED

MATERIAL DUROMETER DESCRIPTIONTEMPERATURE

LIMITS(NNF)

MAT.CODE

NITRILE40 (NOTE 8)

507090

70 (NOTE 4)

N0545-40N299-50 OR N1009-50N674-70N552-90N1173-70

-45 TO +225-45 TO +225-40 TO +250-40 TO +250-25 TO +300

4507180838

ETHYLENE/PROPYLENE5070

75 & 80 (NOTE 2)9075

E981-50E603-70E740-75 & E515-80E962-90 (NOTE 1)E692-75

-65 TO +212-65 TO +212-70 TO +250-70 TO +500

-60 TO +250/400

0119

0231

FLUORO-CARBON 507590

V986-50V747-75 OR V884-75V894-90 OR V709-90

-15 TO +400-15 TO +400-15 TO +400

032205

NEOPRENE 5070

C267-50C944-70 OR C873-70

-45 TO +300-45 TO +300

0910

SILICONE 40 (NOTE 8)5070

S0469-40 OR S0802-40S595-50S604-70

-65 to +400-65 TO +437-65 TO +437

461112

TEFLON 77 TEFLON -300 TO +505 06

Page 35: ENGINEERING INSTRUCTIONS - Swan Associates IncCARBON TETRA-CHLORIDE X X X CARBONIC ACID X X X X X X ENGINEERING INSTRUCTIONS TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

ENGINEERING INSTRUCTIONS

INST. NO. EG060 REV. : 30 TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

DATE: 09/08/00 PAGE 35 OF 42

TABLE III - - - CONTINUED

MATL.MATERIAL DUROMETER DESCRIPTION

TEMPERATURELIMITS

(EEF) CODE

CHEMRAZ 77 (NOTE 3) 65 504 -20 TO +425 (500) 39

CHEMRAZ 77 (NOTE 3) 75 505 -20 TO +425 (500) 24

CHERMAZ 77 (NOTE 3) 90 510 -20 TO +425 (500) 25

CHERMAZ 77 (NOTE 3) 90 600 -4 TO +500 42

CHEMRAZ 77 (NOTE 3) 80 605 -4 TO +500 43

CHEMRAZ 77 (NOTE 3 & 7) 75 615 -0 TO +615 44

FLUOR-SILICONE 60 L0 737-60 -100 TO 350 40

KALREZ (NOTE 3) 85 2035 -50 TO +425 41

KALREZ 77 (NOTE 3) 91 3018 -35 TO +601 33

KALREZ 77 (NOTE 3) 65 1058 -40 TO +500 37

KALREZ 77 (NOTE 5) 82 1050LF -42 TO +550 23

KALREZ 77 (NOTE 6) 75 4079 -58 TO 600 14

NOTE 1: EPR962-90D CAN BE USED ON STEAM SERVICE TO A LOWER PRESSURE LIMIT OF 15 PSIG.

NOTE 2: SET PRESSURE RANGES PER TABLE 2 FOR 70 DUROMETER SHALL APPLY TO THESE COMPOUNDS

(FOR NUCLEAR SERVICE, RADIATION ENVIRONMENT).

NOTE 3: CONSULT WITH APPLICATION ENGINEERING BEFORE SELECTING.

NOTE 4: CONSULT WITH APPLICATION ENGINEERING BEFORE SELECTING FOR USE WITH R134A/ESTEROIL

SERVICE.

CONTINUED ON NEXT PAGE.

Page 36: ENGINEERING INSTRUCTIONS - Swan Associates IncCARBON TETRA-CHLORIDE X X X CARBONIC ACID X X X X X X ENGINEERING INSTRUCTIONS TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

ENGINEERING INSTRUCTIONS

INST. NO. EG060 REV. : 30 TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

DATE: 09/08/00 PAGE 36 OF 42

NOTE 5: SUGGESTED APPLICATIONS:

- COMPLEMENT TO COMPOUND 4079

- STEAM

- AMINES

- BUTADIENE

NOT SUGGESTED FOR:

- ORGANIC ACIDS

- HF ACID

- ETHYLENE OXIDE OR PROPYLENE OXIDE

- TEMPERATURE CYCLING SERVICES

NOTE 6: SUGGESTED APPLICATIONS:

- HIGH TEMPERATURE SERVICES

- TEMPERATURE CYCLING OPERATIONS

- STRONG ACIDS

- GENERAL SOLVENTS

NOT SUGGESTED FOR:

- STEAM

- AMINES

- ETHYLENE OXIDE OR PROPYLENE OXIDE

- BUTADIENE

NOTE 7: NOT FOR STEAM SERVICE

NOTE 8: SET PRESSURES BELOW 15 PSIG ON D, E & F ORIFICES ONLY.

Page 37: ENGINEERING INSTRUCTIONS - Swan Associates IncCARBON TETRA-CHLORIDE X X X CARBONIC ACID X X X X X X ENGINEERING INSTRUCTIONS TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

ENGINEERING INSTRUCTIONS

INST. NO. EG060 REV. : 30 TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

DATE: 09/08/00 PAGE 37 OF 42

TABLE IV

MATERIAL REPLACEMENTS (CONTINUED)

OLD MAT'L CODESPER DWG. NUMBER

OLD MAT'L CODESPER DWG. NUMBER

310 312

NEW MAT'LCODE

310 312

NEW MAT'LCODE

01 18 33 20

05 NONE 34 NONE

07 NONE 35 NONE

08 04 36 14

09 NONE 37 05

10 12 01 20

11 07 02 18

12 NONE 03 04

13 NONE 04 NONE

14 06 05 NONE

16 07 06 12

17 08 07 NONE

18 NONE 08 NONE

20 NONE 09 NONE

21 11 10 05

22 NONE 11 07

23 NONE 12 08

Page 38: ENGINEERING INSTRUCTIONS - Swan Associates IncCARBON TETRA-CHLORIDE X X X CARBONIC ACID X X X X X X ENGINEERING INSTRUCTIONS TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

ENGINEERING INSTRUCTIONS

INST. NO. EG060 REV. : 30 TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

DATE: 09/08/00 PAGE 38 OF 42

TABLE IV

MATERIAL REPLACEMENTS

OLD MAT'L CODESPER DWG. NUMBER

OLD MAT'L CODESPER DWG. NUMBER

310 312NEW MAT'L CODE

310 312

NEW MAT'L CODE

25 NONE 13 NONE

27 NONE 14 NONE

28 NONE 15 11

29 04 16 NONE

30 NONE 17 06

31 NONE 18 04

Page 39: ENGINEERING INSTRUCTIONS - Swan Associates IncCARBON TETRA-CHLORIDE X X X CARBONIC ACID X X X X X X ENGINEERING INSTRUCTIONS TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

ENGINEERING INSTRUCTIONS

INST. NO. EG060 REV. : 30 TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

DATE: 09/08/00 PAGE 39 OF 42

TABLE V

SIZE REPLACEMENTS

OLDSIZE CODE

NEW 310SIZE CODE

310 XX 02 310 XX 012

312 XX 36 310 XX 014

310 XX 31 310 XX 110

310 XX 17 310 XX 112

310 XX 37 310 XX 113

310 XX 38 310 XX 114

310 XX 13 310 XX 116

310 XX 48 310 XX 118

310 XX 19 310 XX 119

310 XX 03 310 XX 212

310 XX 32 310 XX 215

310 XX 09 310 XX 220

310 XX 07 310 XX 326

310 XX 36 310 XX 329

310 XX 01 310 XX 332

310 XX 24 310 XX 333

310 XX 19 310 XX 338

310 XX 25 310 XX 346

310 XX 10 310 XX 428

310 XX 40 310 XX 437

Page 40: ENGINEERING INSTRUCTIONS - Swan Associates IncCARBON TETRA-CHLORIDE X X X CARBONIC ACID X X X X X X ENGINEERING INSTRUCTIONS TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

ENGINEERING INSTRUCTIONS

INST. NO. EG060 REV. : 30 TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

DATE: 09/08/00 PAGE 40 OF 42

R E V I S I O N S H E E T

REVISIONS MADE TO THIS INSTRUCTION ARE LISTED IN DETAIL AND CHRONOLOGICAL ORDER

RELEASENO. & DATE

REV.NO.

DESCRIPTION

GB96007/30/97LMW

12 INSERTED SUB PAR 1.2.

GB97809/16/97MLC

13 PAGE 1, PAR. 1.1: INSERTED AAAND 3900" AFTER AA19000".PAGE 24, TABLE 2: NEW ADDITION TO TABLE 2.

GB99010/09/97MLC

GC48901/08/98LMW

14

15

PAGE 24, TABLE 2: 75-1500 WAS 75-1100.

PAGE 25--TABLE 3. MATERIAL NITRILE/DESCRIPTION N674-70 --ADD 18 TO MATCODE.MATERIAL ETHYLENE/PROPYLENT/DESCRIPTION E603-70--ADD 19 TO MATCODE.

GC38902/26/98MLC

16 PAGE 1: REVISED ENTIRE PARAGRAPH PAR. 2.2.1.1ADDED SUB PARS. 2.2.1.2.1 TO 2.2.1.3, AND PAR. 2.2.1.2.

PAGE 2: DELETED PAR. 2.2.2.1, NUMBER ONLY BUT RETAINED TEXT.DELETED PAR. NUMBERS 3.2.1. AND 3.3.1, BUT RETAINED TEXT.

PAGE 25: ON TABLE 3, ADDED AAKALREZ@@ AND ITS VALUES.

GC41503/12/98MLC

17 PAGE 25: ON TABLE 3, SECOND ROW, ADDED THE FOLLOWING VALUES:70 , N1173-70, -25 TO +300, AND 38.

GC52404/09/98MLC

18 PAGE23: ON TABLE 2, ADDED AAT-4, V, & W@@

Page 41: ENGINEERING INSTRUCTIONS - Swan Associates IncCARBON TETRA-CHLORIDE X X X CARBONIC ACID X X X X X X ENGINEERING INSTRUCTIONS TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

ENGINEERING INSTRUCTIONS

INST. NO. EG060 REV. : 30 TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

DATE: 09/08/00 PAGE 41 OF 42

R E V I S I O N S H E E T

REVISIONS MADE TO THIS INSTRUCTION ARE LISTED IN DETAIL AND CHRONOLOGICAL ORDER

GC585

05/29/98

MLC

19 PAGES 23-24: ON TABLE II, COLUMN 3, CELL 3, THE VALUE AA70@@ WAS CHANGED

TO AA70 TO 75.@@

PAGE 25: ON TABLE III, COLUMN 2 & 3, CELL 3, VALUES WERE CHANGED TO:

75; V747-75 OR V884-75; -15 TO +400; AND 22.

GC72312/21/98LMW

20 PAGE 27: TABLE III---ETHYLENE/PROPYLENE-- ADD TO DUROMETER:75ADD TO: DESCRIPTION-- E692-75ADD TO: TEMPERATURE LIMITS(°°F)-- -60 TO +250/400ADD TO: MAT. CODE-- 31

FJ71505/18/99diw

21 ADDED NEW PAGE 27 FOR VALVE TYPE 3900-4. RENUMBERED FOLLOWING PAGES.

FJ97607/28/99diw

22 PAGE 28: ON TEFLON & KALREZ ADDED 77 .ADDED CHEMRAZ 77

FK14208/18/99diw

23 PAGE 25: ADDED 19110.ON VALVE TYPE 19096, ADDED ASTERICK. ON 19096 COLUMN (1) 70 TO75. 100-500 WAS 50-500.

FK99102/22/00diw

24 PAGE 23: ON VALVE TYPE V & W, DELETED 15-300 FROM -300 TO 200°°F COLUMN.ADDED NEW PAGE 25 FOR 19000PF O-RING SELECTION. RENUMBERED FOLLOWING PAGES.

FL04002/29/00diw

25 PAGE 27: ON TEFLON COLUMN, 201 TO 500°°F 50 WAS 15.

FL059A03/06/00diw

26 PAGE 1: ON PARA. 1.1, ADDED 2900.ON PARA. 2.2.1.1, ADDED 2900.

ADDED NEW PAGE, 25, RENUMBERED FOLLOWING PAGES.

Page 42: ENGINEERING INSTRUCTIONS - Swan Associates IncCARBON TETRA-CHLORIDE X X X CARBONIC ACID X X X X X X ENGINEERING INSTRUCTIONS TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

ENGINEERING INSTRUCTIONS

INST. NO. EG060 REV. : 30 TITLE: “O” RING SELECTION FOR SAFETY RELIEF VALVES

DATE: 09/08/00 PAGE 42 OF 42

R E V I S I O N S H E E T

REVISIONS MADE TO THIS INSTRUCTION ARE LISTED IN DETAIL AND CHRONOLOGICAL ORDER

FL139B03/16/00diw

27 PAGE 1: ON PARA. 1.1, ADDED & 4900.ON PARA. 2.2.1.1 ADDED & 4900.

FL46206/08/00diw

28 PAGE 1: ON PARA. 2.2.1.2.1, 50 PSIG WAS 25 PSIG.PAGE 25: REVISED TABLE 2900 IN ITS ENTIRETY.PAGE 27 : REVISED TABLE 3900-3 IN ITS ENTIRETY.PAGE 28: REVISED TABLE 3900-4 IN ITS ENTIRETY.PAGE 29: ADDED NEW TABLE FOR 4900.

FL85608/16/00diw

29

PAGE 27: CHEMRAZ, MAT’L. CODES 39, 24 & 25, +425 WAS +450 ADDED CHEMRAZ, MAT;L CODES 42, 43 & 44; FLUOR-SILICONE & KALREZ.

PAGE 28: ADDED KALREZ, MAT’L. CODES 23 & 14; NOTES 5, 6 & 6.

FL94109/08/00diw

30

REVISED & RETYPED IN ITS ENTIRETY.

PAGE 34: ON MAT’L. NITRILE, ADDED 40 (NOTE 8) TO DUROMETER COLUMN.ADDED N0545-40 TO DESCRIPTION COLUMN. ADDED –45 TO +225, TOTEMPERATURE LIMITS COLUMN. ADDED 45 TO MAT’L. CODE COLUMN. ON SILICONE MAT’L. COLUMN, ADDED 40 (NOTE 8) TO DUROMETER COLUMN.ADDED S0469-40 OR S0802-40 TO DESCRIPTION COLUMN. ADDED –65 TO +400 TOTEMPERATURE LIMITS COLUMN. ADDED 46 TO MAT’L. CODE COLUMN.