Engineer Training
Electrical System Overview and Requirements
Confidential 2
Engineer Training
XL1500 Electric + PDU’s
Monitor
Co
mp
ute
r
40 VPowerSupply
24 VPowerSupply
220 V
220V
220 V
220 V
220 V
220 V
220 V
220 V
220VPo
we
r S
plit
er
MotorCollector
Infra Red Heating System
Dri
ver
Dri
ver
Dri
ver
Dri
ver
Motor Motor
MotorMotorMotionController
EmergencyContactor
24 V in
24 V out
Ma
in E
lect
ric
Ca
bin
et
Block Diagram
Confidential 3
Engineer Training
XL1500 Electric + PDU’s
PDU Latest Revision – Inside Look
Confidential 4
Engineer Training
XL1500 Electric + PDU’s
Upper PDU Components
1 2
3
4
Temp. controllers 1. IR Temp. controller 2. Heating table Temp. controller
3. Phase Contactors 55A
4. For the driversFor the IR
Temp controllers adjustment procedure
Confidential 5
Engineer Training
XL1500 Electric + PDU’s
Mid Level – Inside Look
Circuit breaker 3 phase, 63A
Main Switch S1
Lamps 220v
Fuse holder
Confidential 6
Engineer Training
XL1500 Electric + PDU’s
Lower Level-PDU
UPS rotary switch
Circuit breakers2*6A7*10A2*16A Main filter
3 Phases
Confidential 7
Engineer Training
XL1500 Electric + PDU’s
PDU – Main Safety
Safety relay
Confidential 8
Engineer Training
XL1500 Electric + PDU’s
PDU – Main Safety
Phase R starts the following loops:
Phase R UPS K1
K1 is the Safety relay – Responsible for shutting down the motion system in case of emergency.
When the 24v loop is cut, emergency is active.
Confidential 9
Engineer Training
XL1500 Electric + PDU’s
Open Cabinet – Old Revision
Confidential 10
Engineer Training
XL1500 Electric + PDU’s
Upper PDU
We have the following parts:
1. Temperature Display / Control for the Heating Table.
2. Heating Hood Row Selection / OFF Switch
3. Heating Hood Zone Selection Switch
1
2 3
Confidential 11
Engineer Training
XL1500 Electric + PDU’s
Mid Level PDU
Heating Hood 3 Phase Magnetic Relay
Here is where the computerturns on the heating.
Power Pilot Lamps. (Right)
Fuses for the Pilot Lamps(Left)
Main PowerBreaker
Main PowerSwitch
Confidential 12
Engineer Training
XL1500 Electric + PDU’s
Lower Level PDU
Main PowerFilter
Surge / SpikeSuppressor
CircuitSafety SystemRelay
Heating TableRelay
UPS / MainSelector Switch
Confidential 13
Engineer Training
XL1500 Electric + PDU’s
New PDU (UL Certified) – Last Revision
New Safety Relay
New Safety relay K3 (the same relay type as used for activating the Drying System) for the drivers replaces the old problematic one.
The K3 relay has been moved to a new position, and the RL3 relay is installed into its place (see Figure 4).
K3
RL3
Confidential 14
Engineer Training
XL1500 Electric + PDU’s
Last PDU Revision (UL Certified)
Confidential 15
Engineer Training
XL1500 Electric + PDU’s
Last PDU Revision (UL Certified) (Cont.)
New Main 3-phase Circuit Breaker
The main Circuit Breaker F1 (see green line) includes the Switch Tripped mechanism (terminals 9,10). The two phases are connected (see dashed green line) via the Emergency Switch.
When the Switch Tripped is powered, the F1 contacts are closed and the machine is connected to the power line.
When the Emergency Switch is pressed, the Switch Tripped will be powered off and the F1 contacts will be opened,(i.e. the machine will be disconnected from the power line).
Confidential 16
Engineer Training
XL1500 Electric + PDU’s
Last PDU Revision (UL Certified) (Cont.)
New Emergency Stop Button
The new PDU is equipped with its own Emergency Stop button
When pressed, the RL3 relay will be activated and the electrical power will be disconnected before the Main 3-phase Circuit Breaker and from the UPS to the machine – see Figure (next slide).
Confidential 17
Engineer Training
XL1500 Electric + PDU’s
Main Safety – PDU
To UPS
Confidential 18
Engineer Training
XL1500 Electric + PDU’s
Main Safety – PDU
The green dash line marks the circuit UPS Emergency Switch RL3 coil UPS. When the Emergency Switch is pressed, this circuit is open.
The cyan dot line specifies the circuitUPS RL3 contacts Drivers Left Cabinet(PC, Power Supplies) UPS. When the Emergency Switch is pressed, this circuit is open.
The magenta dot line specifies the self-sustain loop for holding the RL3 powered in case of general electric failure(i.e. Switch Tripped is not powered and the green circuit is open).
Confidential 19
Engineer Training
XL1500 Electric + PDU’s
PDU with Heating Control Unit (External or Built-in)
Confidential 20
Engineer Training
XL1500 Electric + PDU’s
XL Premium – PDU
Confidential 21
Engineer Training
XL1500 Electric + PDU’s
XL Premium – PDU
1. XL Premium printing table has an Extra 5 heating table elements (Total of 10 heating elements).
2. Circuit breaker on the PDU is changed from 16A to 20A in order to support it.
3. Controlling the heating tables is from the Printing table heating controller (F5 circuit breaker on the PDU)
4. Once the heating table gives signals that the current temperature is lowered then the desired temperature, a 24v input signal will operate the SSR and the heating table will work.
Confidential 22
Engineer Training
XL1500 Electric + PDU’s
XL Premium – PDU
20A Circuit breaker