8
imc – productive testing imc CANSASfit clickable • small • temperature resistant Robust measurement modules for mobile applications

eng-imc CANSAS-FIT 2015 - INSTRUMENTATION...2016/05/02  · CANSAS fit imc-Italy una divisione di _2016-01_eng // Errors and changes excepted. All registered trademarks are the property

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: eng-imc CANSAS-FIT 2015 - INSTRUMENTATION...2016/05/02  · CANSAS fit imc-Italy una divisione di _2016-01_eng // Errors and changes excepted. All registered trademarks are the property

imc – productive testing

imc CANSASfitclickable • small • temperature resistant

Robust measurement modules for mobile applications

Page 2: eng-imc CANSAS-FIT 2015 - INSTRUMENTATION...2016/05/02  · CANSAS fit imc-Italy una divisione di _2016-01_eng // Errors and changes excepted. All registered trademarks are the property

www.imc-berlin.com

At a glance

imc CANSASfit

• Measurement modules for voltage/current, temperature,

pulse signals

• Operates from -40°C to +125°C; condensation allowed

• Robust housing with IP65 protection rating, MIL STD-810F

• Connecting modules without cables or tools (click-mechanism)

• Central or distributed installations

• Complete galvanic isolation

• Measurement data output to CAN

• Includes configuration software

Page 3: eng-imc CANSAS-FIT 2015 - INSTRUMENTATION...2016/05/02  · CANSAS fit imc-Italy una divisione di _2016-01_eng // Errors and changes excepted. All registered trademarks are the property

Measurement systems for the automobile industry

must be robust and compact because the operating

environments, e.g., in the engine compartment, can be

hot and crowded. The new imc CANSASfit series works

reliably from -40° to +125°C, is rated at IP65 and due

to its small design, can be placed almost anywhere.

The modules allow for direct connection to all typical

sensors such as voltage, current, temperature, rpm,

displacement and velocity. The digitized measurement

signals are output as CAN messages and can be read

or recorded by any measurement, automation or con-

trol system with a CAN interface.

Click-mechanism for more comfort

By means of the imc click-mechanism, imc CANSASfit

modules allow for a quick connection: both mechani-

cally and electrically. Thus, the user can simply click

modules together to create blocks. Wiring between the

modules is not necessary.

Data logger to supplement imc CANSAS modules

These measurement modules are perfectly com-

plemented by an imc data logger – such as the imc

CRONOScompact or imc BUSDAQ. In ECU development

and testing, they provide for acquisition and real-time

processing of measurement information from vehicle

and field buses.

Smart measurement modules for mobile applications

Productive testing: road trials

Voltage Current 20mA Temperature

I 0

U i ƒI 0

out dB vid

011001011010011001

ƒ

Pulse counter

RTD/NTC

I 0

U i ƒI 0

out dB vid

011001011010011001

Digital input/output

Advantages// 03

Ad

van

tag

esIn

Pra

ctic

eFa

cts

& F

eatu

res

Page 4: eng-imc CANSAS-FIT 2015 - INSTRUMENTATION...2016/05/02  · CANSAS fit imc-Italy una divisione di _2016-01_eng // Errors and changes excepted. All registered trademarks are the property

www.imc-berlin.com

CAN-based systems

• For vehicle testing, test stands and laboratory use

• Distributed and granulated topologies

Mechanics

• IP65 protection rating for tough environments

• Extreme temperature range: -40°C to +125°C

• Power supply and CAN: LEMO.0B (5-pin),

I/O: LEMO.0B or LEMO.1B (6-pin)

Compact design

• L138 x W31 x H53 mm

• Minimal module size allows for placement in

crowded spaces

• Multiple mounting options: Click connect to blocks.

Integrated mounting holes (e.g., for cable ties)

• Die-cast aluminum housing

High-precision analog inputs

• Individually converted: 24 bit sigma-delta ADCs

• Fully-isolated (channel-to-channel): 300V

• Fully-isolated and individual sensor power supply

Signal processing

• Channel-specific signal filtering incl. automatic

anti-aliasing filter

• Status LEDs and cable-break detection

Configuration software

• imc CANSAS software allows measurement module

configuration

• Self-start with saved configuration

• Also available: factory pre-configured

Productive testing and digitalization with imc CANSASfit

imc CANSASfit-T-10

1 2 3 4 5 6 7 8 9 10

Mounting holes (e.g., for cable ties)

Robust housing, IP65, MIL STD-810F

CAN + Power LEMO.0B

I/O-connections, LEMO.0B or LEMO.1B, thermo-connectors

Click mechanism

Page 5: eng-imc CANSAS-FIT 2015 - INSTRUMENTATION...2016/05/02  · CANSAS fit imc-Italy una divisione di _2016-01_eng // Errors and changes excepted. All registered trademarks are the property

imc CANSASfit-T-10

1 2 3 4 5 6 7 8 9 10

CAN + Power LEMO.0B

Click mechanism

In Practice

Fit for endurance testing

Before the first customer vehicle rolls off the assembly

line, endurance testing must be carried out to verify the

quality of the entire vehicle. The car’s life expectancy

is tested by accelerated simulation under the harshest

conditions. Fleets are tested for thousands of kilome-

ters on country roads, freeways and city environments.

With imc CANSASfit measurement modules, you are

always ready to handle such testing requirements. Whe-

ther in the engine compartment or behind a side panel:

due to their compact design, they can be placed almost

anywhere. Furthermore, in combination with a data log-

ger, all sensor data, control information and GPS data

can be autonomously acquired.

Fit for climate / HVAC testing

Whether in a climate chamber, in the desert or in the

arctic, imc CANSASfit can accurately take measure-

ments in temperatures from -40°C to +125°C. The

sealed housing design protects the module from conden-

sation and corrosion. Even under harsh environmental

conditions, the modules operate reliably: imc CANSASfit

has an IP65 protection rating and is resistant to dirt,

water spray, vibration and shocks. In addition, the

compact design makes the modules ideal for the engine

compartment.

Fit for distributed tests in plants and machinery

In large installations and machines, such as wind tur-

bines, the measuring points are often far apart. In this

type of setting, a spatially-distributed measurement

system has clear advantages. Taking the measurements

close to the sensor reduces the amount of wiring and

minimizes the chance of electrical interference. As a

result, the quality of the measurement results is incre-

ased, as well as saving time and money. Combining the

imc CANSASfit with an imc data logger lets you create

multi-channel measurement networks, even over long

distances.

In Practice // 05

In P

ract

ice

Fact

s &

Fea

ture

s

Page 6: eng-imc CANSAS-FIT 2015 - INSTRUMENTATION...2016/05/02  · CANSAS fit imc-Italy una divisione di _2016-01_eng // Errors and changes excepted. All registered trademarks are the property

U i

I 0

imc CANSASfit modules

Signals & Sensors

imc data logger

Configuration & Online-Visualization

LA

N,

Eth

ern

et,

W

LA

N

ECUs

ƒ

www.imc-berlin.com

Page 7: eng-imc CANSAS-FIT 2015 - INSTRUMENTATION...2016/05/02  · CANSAS fit imc-Italy una divisione di _2016-01_eng // Errors and changes excepted. All registered trademarks are the property

imc CANSASfit Details Functions and specifications

size connector speed isolation modes voltage mode supply

mod

ule

nam

e C

AN

FT

chan

nel

s

con

nec

tor

op

tio

ns

max

.sam

plin

g r

ate

(per

ch

ann

el)

sig

nal

ban

dw

idth

(-

3d

B)

gal

van

ical

ly is

olt

aed

per

ch

ann

el

iso

lati

on

vo

ltag

e

volt

age

curr

ent

(20

mA

)

RT

D (

PT

10

0..

.P

T1

00

0)

NT

C,

resi

stan

ce

(5 o

hm

...

10

0 k

Oh

m)

ther

mo

co

up

le

sen

sor

sup

ply

min

. vo

ltag

e ra

ng

e (m

V)

max

. vo

ltag

e ra

ng

e (V

)

min

. su

pp

ly

max

. su

pp

ly

ou

tpu

t p

ower

per

ch

ann

el

ind

ivid

ual

ly is

ola

ted

analog modules

T-10 10 Thermo (Uni) 100 Hz 20 Hz 300 V

UTI-6 6 6 x LEMO 1000 Hz 400 Hz 300 V 25 mV 60V ±2,5V ±15 V 0,4 W

Analog Modules

size connector speed isolation operation modes

mod

ule

nam

eC

AN

FT

chan

nel

s

con

nec

tor

op

tio

ns

max

.sam

plin

g r

ate

(per

ch

ann

el)

sig

nal

ban

dw

idth

(-

3d

B)

gal

van

ical

ly is

olt

aed

iso

late

d g

rou

ps

iso

lati

on

vo

ltag

e

mo

des

con

dit

ion

ing

pulse counter

ENC-6 6 6 x LEMO 1000 Hz 2 Mhz 2 300 V displacement, angle, time, frequency, speed, RPMdifferential inputs, filter,

adjustable thresholds

digital I/0

DI-16 16 4 x LEMO 1000 Hz 4 300 V Port / Bits 24V / 5V Logic

DO-16 16 4 x LEMO 1000 Hz 4 300 V Port / Bits24V / 5V HighSide / LowSide / TotemPole

Digital Modules

Legend: standard, optional

Facts & Features // 07

Fact

s &

fea

ture

s

Page 8: eng-imc CANSAS-FIT 2015 - INSTRUMENTATION...2016/05/02  · CANSAS fit imc-Italy una divisione di _2016-01_eng // Errors and changes excepted. All registered trademarks are the property

imc

CA

NS

AS

fit_

20

16

-01

_en

g /

/ E

rro

rs a

nd

ch

ang

es e

xcep

ted

. A

ll re

gis

tere

d t

rad

emar

ks a

re t

he

pro

per

ty o

f th

e re

spec

tive

co

mp

anie

s.

imc-Italy una divisione di

Instrumentation Devices Srl, distribuisce e supporta in Italia i prodotti e

le soluzioni di imc Meßsysteme GmbH.

Via Acquanera 29

22100, Como (CO) Italia

Tel: +39.031.52.53.91

[email protected]

www.imc-italy.com

imc Meßsysteme GmbHVoltastraße 5

13355 Berlin

Germany

Tel.: +49 (0)30 - 46 70 90 26

Fax: +49 (0)30 - 463 15 76

[email protected]

www.imc-berlin.com

Partner Italiano di imc dal 1993

w w w . i n s t r u m e n t a t i o n . i t