Endurance test
Glass beads
© 2016 Jet Clean Systems AG Seite 1 von 6 erstellt: 21.11.2016 Gae
gedruckt: 28.11.2016
Endurance test glass beads
1. Test planning
1.1 Basic information
Project: Dauertest Glasperlen
Process, devices Suspension Injection | System: 170/10
Pressure [bar] 120 bar
Abrasive (type, size) Al2O3 Garnet glassbeads | Mesh size: 0 - 50µm
Abrasive perc. [m%] Ca. 5%
Nozzle (type, size) Fanjet nozzle 0.76 x 40°
Handling devices yes, type: Kuka KR 3 no (manual trial))
1.2 Test descriptio
By using Suspension Technology, a stainless steel plate was blasted with glass beads and a
stand-off distance of approx. 50mm for an extended time in a closed loop. By analysing the glass
beads optically by a microscope after defined intervals the wear on the beads was determined.
1.3 Parameter
Pressure: 120bar
Stand-off distance: 50mm
Suspension perc.: 5%
Abrasive media: Glass beads 0 – 50 µm
Endurance test
Glass beads
© 2016 Jet Clean Systems AG Seite 2 von 6 erstellt: 21.11.2016 Gae
gedruckt: 28.11.2016
2. Evaluation
2.1 Results
Inital state of glass beads (dry); including size measurement
Glass beads after 60 minutes blasting time (wet) including size measurement
Endurance test
Glass beads
© 2016 Jet Clean Systems AG Seite 3 von 6 erstellt: 21.11.2016 Gae
gedruckt: 28.11.2016
Glass beads after10 minutes blasting time (wet)
Glass beads after 20 minutes blasting time (wet)
Endurance test
Glass beads
© 2016 Jet Clean Systems AG Seite 4 von 6 erstellt: 21.11.2016 Gae
gedruckt: 28.11.2016
Glass beads after 30 minutes blasting time (wet)
Glass beads after 40 minutes blasting time (wet)
Endurance test
Glass beads
© 2016 Jet Clean Systems AG Seite 5 von 6 erstellt: 21.11.2016 Gae
gedruckt: 28.11.2016
Glass beads after 50 minutes blasting time (wet)
Glass beads after 60 minutes blasting time (wet)
Endurance test
Glass beads
© 2016 Jet Clean Systems AG Seite 6 von 6 erstellt: 21.11.2016 Gae
gedruckt: 28.11.2016
2.2 Conclusion
The optical investigation confirms that the glass beads are not fragmented. On the basis of the
surveying photos before and after the blasting no difference in the grain size distribution could
be determined.