6
Endurance test Glass beads © 2016 Jet Clean Systems AG Seite 1 von 6 erstellt: 21.11.2016 Gae gedruckt: 28.11.2016 Endurance test glass beads 1. Test planning 1.1 Basic information Project: Dauertest Glasperlen Process, devices Suspension Injection | System: 170/10 Pressure [bar] 120 bar Abrasive (type, size) Al2O3 Garnet glassbeads | Mesh size: 0 - 50μm Abrasive perc. [m%] Ca. 5% Nozzle (type, size) Fanjet nozzle 0.76 x 40° Handling devices yes, type: Kuka KR 3 no (manual trial)) 1.2 Test descriptio By using Suspension Technology, a stainless steel plate was blasted with glass beads and a stand-off distance of approx. 50mm for an extended time in a closed loop. By analysing the glass beads optically by a microscope after defined intervals the wear on the beads was determined. 1.3 Parameter Pressure: 120bar Stand-off distance: 50mm Suspension perc.: 5% Abrasive media: Glass beads 0 50 μm

Endurance test glass beads - Jet Clean Systems AG

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Endurance test

Glass beads

© 2016 Jet Clean Systems AG Seite 1 von 6 erstellt: 21.11.2016 Gae

gedruckt: 28.11.2016

Endurance test glass beads

1. Test planning

1.1 Basic information

Project: Dauertest Glasperlen

Process, devices Suspension Injection | System: 170/10

Pressure [bar] 120 bar

Abrasive (type, size) Al2O3 Garnet glassbeads | Mesh size: 0 - 50µm

Abrasive perc. [m%] Ca. 5%

Nozzle (type, size) Fanjet nozzle 0.76 x 40°

Handling devices yes, type: Kuka KR 3 no (manual trial))

1.2 Test descriptio

By using Suspension Technology, a stainless steel plate was blasted with glass beads and a

stand-off distance of approx. 50mm for an extended time in a closed loop. By analysing the glass

beads optically by a microscope after defined intervals the wear on the beads was determined.

1.3 Parameter

Pressure: 120bar

Stand-off distance: 50mm

Suspension perc.: 5%

Abrasive media: Glass beads 0 – 50 µm

Endurance test

Glass beads

© 2016 Jet Clean Systems AG Seite 2 von 6 erstellt: 21.11.2016 Gae

gedruckt: 28.11.2016

2. Evaluation

2.1 Results

Inital state of glass beads (dry); including size measurement

Glass beads after 60 minutes blasting time (wet) including size measurement

Endurance test

Glass beads

© 2016 Jet Clean Systems AG Seite 3 von 6 erstellt: 21.11.2016 Gae

gedruckt: 28.11.2016

Glass beads after10 minutes blasting time (wet)

Glass beads after 20 minutes blasting time (wet)

Endurance test

Glass beads

© 2016 Jet Clean Systems AG Seite 4 von 6 erstellt: 21.11.2016 Gae

gedruckt: 28.11.2016

Glass beads after 30 minutes blasting time (wet)

Glass beads after 40 minutes blasting time (wet)

Endurance test

Glass beads

© 2016 Jet Clean Systems AG Seite 5 von 6 erstellt: 21.11.2016 Gae

gedruckt: 28.11.2016

Glass beads after 50 minutes blasting time (wet)

Glass beads after 60 minutes blasting time (wet)

Endurance test

Glass beads

© 2016 Jet Clean Systems AG Seite 6 von 6 erstellt: 21.11.2016 Gae

gedruckt: 28.11.2016

2.2 Conclusion

The optical investigation confirms that the glass beads are not fragmented. On the basis of the

surveying photos before and after the blasting no difference in the grain size distribution could

be determined.