EMISSIONS CAN BE PROFITABLE
Speaker: Jürgen Hemsing, Nießing Anlagenbau
2
Metal constructions
Plant constructionSteel chimneys
Silencers
The both new silencer-systems of Nießing
In a Daimler AG painting plant, the polluted mineral wool silencers are to be replaced with modern plate silencers. The conventional silencers are clotted with residual paint and are ineffective. 60 % of the cross section will be blocked by the built-in components.
Modern silencer systems for modern vehicles.The individual plate silencer modules are prepared for assembly.
The modules will be installed using a crane to position them over the mouth of the chimney. All modules will be gradually mounted via rails and with zero stress.
To achieve the stipulated silencer length of 17.5 m, individual modules of 2.5 m each will be bolted together.
An accordingly calculated steel construction at the mouth serves as a suspension for the entire silencer. The silencer can thus expand with the temperature.
By means of the nesting construction, a total of 28 individual channels with a quadratic dimension of 1.2 m * 1.2 m emerge.
Before After
-35 dB(A)
>35-40 dB(A)
>40-45 dB(A)
>45-50 dB(A)
>50-55 dB(A)
>55-60 dB(A)
>60-65 dB(A)
>65-70 dB(A)
>70-75 dB(A)
>75-80 dB(A)
>80-110 dB(A)
Noise Mapping of the Entire Plant
Sound power prior to and following the installation of the plate silencers
80
82
84
86
88
90
92
94
96
98
2001 2003 2004 2005 2006 2007 2008
dB(A
)
Increase in the level due to the soiled conventional silencers
In 2006, no further noise measurement was performed, as the reconstruction using new silencers was already planned. Plate silencers were installed in
2007. .
Lower and more constant level with plate
silencers
Chimney335
Chimney331
Chimney336
DAIMLER, DüsseldorfModernizing the Silencer
Reduction in the Annual Energy Consumption Total Savings app. 7600 MWh / a.
4998
1554
3384
0
1000
2000
3000
4000
5000
6000
Kulissenschalldämpfer Plattenschwinger Einsparung
Meg
aw
att
/ a
Energy Savings Chimney 331
5538
1308
4230
0
1000
2000
3000
4000
5000
6000
Kulissenschalldämpfer Plattenschwinger Einsparung
Meg
aw
att
/ a
Energy Savings Chimney 335
Reduction in Operational CO2 EmissionsTotal Savings app. 3020 Tons CO2/p.a. which is Equivalent
to 1030 4‐Pers. Households
1984
617
1343
0
500
1000
1500
2000
2500
Kulissenschalldämpfer Plattenschwinger Einsparung
ton
nen
CO
2
CO2 Equivalent Chimney 331
2198
519
1679
0
500
1000
1500
2000
2500
Kulissenschalldämpfer Plattenschwinger Einsparung
ton
nen
CO
2
CO2 Equivalent Chimney 335
Reduction in the Plant´s Energy CostsTotal Savings of app. 610.000 € /a
399.840 €
124.320 €
275.520 €
0 €
50.000 €
100.000 €
150.000 €
200.000 €
250.000 €
300.000 €
350.000 €
400.000 €
450.000 €
Kulissenschalldämpfer Plattenschwinger Einsparung
Energy Costs Chimney 331
443.040 €
104.640 €
338.400 €
0 €
50.000 €
100.000 €
150.000 €
200.000 €
250.000 €
300.000 €
350.000 €
400.000 €
450.000 €
500.000 €
Kulissenschalldämpfer Plattenschwinger Einsparung
Energy Costs Chimney 335
Thank you for your attention !!