6
MXTG2-STLA300 (1” Regress) B W SN Available finishes AB WH B W SN Available finishes AB WH MXG2ASTL 3.5” MX G2 LED Square Trimless Adjustable FEATURES Multiple architectural trim options High center beam spot up to 24,500 CBCP Dedicated 9° with field changeable 12°, 24°, 36° & 50° optics LED LIGHT ENGINE 92 CRI & 82 CRI in 2700K, 3000K, 3500K and 4100K with 2 SDCM binning >50,000 hours L70 (rated life at 70% output) ELECTRICAL SYSTEM Multiple dimming drivers available (Non-IC) 120V or 277V input; Power factor >.9 50/60Hz (-IC) Universal 120V/277V input; Power factor >.9 50/60Hz This product complies with IEEE C62.41 for surge endurance up to 2.5KV. Additional surge protection recommended. Damage from power surge is not covered by warranty. DIMMING 0-10V Dimming 1% Forward/reverse dimming 1% (120V only) EldoLED 0-10V 0.1% or 1% Lutron ® LDE1 Hi-Lume 1% EcoSystem LED driver with Soft-on, Fade-to-Black dimming technology Lutron ® LTEA2W Hi-Lume 1% 2-Wire LED driver (120V forward phase only) DMX512 RDM 0.1% HOUSING Heavy duty black powder coated 18 gauge steel frame Standard housing accommodates 5/8” ceiling thickness Extended collar options available for ceilings up to 1” or 2” thick, must specify either EC1 or EC2 (EC1/EC2) INSTALLATION Housing types include IC Air-Tight or Non- IC Rated (must specify). Non-IC rated housings must be kept at a minimum of 3” away from insulation. Butterfly brackets are compatible with adjustable bar hangers (14”-25”) and EMT. Bar hangers must be ordered separately. Max. ambient temperature: 131°F (55°C). TRIM SPECIFICATION Aiming with locking 35° vertical and 360° horizontal adjustment with 1/2” regress and 90° turns (90, 180, 270 and 360) with 1” regress for greater visual comfort. See fixture aiming chart on page 2. High quality trims are die-cast using A380 aluminum with durable powder coat available in multiple finishes. Perforated mesh frame is die-cast to a 0.8mm thickness to easily adhere to joint compound for seamless and trimless mounting. Trims available in 1” regress for greater visual comfort or 1/2” regress for consistent look throughout space. EMERGENCY BACKUP Remote test switch included. External battery operates LED load at a minimum of 500 to 850 lumens for 90 minutes, depending on backup wattage selected. See trim multipliers for detailed performance. Servicing requires above ceiling access. LISTING / WARRANTY 5-Year Intense LED Limited Warranty ETL listed to US and Canadian standards for damp locations (-IC Only) Air-Tight Certified ASTM E283 (-IC Only) ETL listed for direct contact w/insulation ENERGY STAR ® Qualified 1 Can be used to comply with 2016 Title 24, Part 6, JA8 high efficacy LED light source requirements 2 2 1 Housing dimensions are on Page 2 1/2” 3 1/2” 3 1/2” 1” MXTG2-STLR300 (1/2” Regress) Notes: 1. ENERGY STAR ® Qualified (White reflectors only; Excludes: L2, L3, 92 CRI & 9° options) 2. Excludes: L2, L3, 82 CRI & 9° options 3. L3 available with Non-IC housings only 4. Available in 120V only 5. Not Available in L3 6. Not Available in L2 & L3 7. DMX512 RDM not available in L0 & L1 8. Access above ceiling required 9. Not available in L0 10. 9° Narrow spot not available in L2 & L3 Housing Part Number (Example: MXG2ASTL-ICL1) Housing Installation Type Ceiling Thickness Wattage Dimming Voltage Options MXG2ASTL -NC -IC (Non-IC) (Air-Tight IC) blank EC1 EC2 (5/8”) (1”) (2”) L0 L1 L2 L3 3 (10W) (16W) (20W) (26W) blank DELV 4 D101 ED10V1 5 ED10V01 5 LUT 6 LUT2 4 DMXR 7 (Non-Dimming) (Phase Dimming) (0-10V Dimming 1%) (eldoLED 0-10V 1%) (eldoLED 0-10V 0.1%) (Lutron ® LDE1 EcoSystem 1%) (Lutron ® LTEA2W 2-Wire 1%) (DMX512 RDM 0.1%) blank 27 (Non-IC: 120V -IC: 120V/277V) (277V Non-IC Only, for -IC housing options use blank) I100 I200 I400 -EM7 8 -EM12 8, 9 (C-Channel Bar Hangers) (Flat Bar Hangers) (Wood Joist Bar Hangers) (7W Emergency Backup IOTA Part #ILB-CP07-A) (12W Emergency Backup IOTA Part #ILB-CP12-A) Trim Part Number (Example: MXTG2-STLA300WL13024) Trim Finish Wattage CCT / CRI Optic MXTG2-STLA300 (1” Regress) MXTG2-STLR300 (1/2” Regress) B W SN AB WH (Black) (White) (Satin Nickel) (Antique Bronze) (Wheat) L0 L1 L2 L3 3 (10W) (16W) (20W) (26W) 27 279 30 309 35 359 41 419 (2700K / 82 CRI) (2700K / 92 CRI) (3000K / 82 CRI) (3000K / 92 CRI) (3500K / 82 CRI) (3500K / 92 CRI) (4100K / 82 CRI) (4100K / 92 CRI) 09 10 12 24 36 50 (9° Narrow Spot) (12° Spot) (24° Narrow Flood) (36° Flood) (50° Wide Flood) ELECTRICAL DATA LED Light Engine System Wattage * CCT / CRI Delivered Lumens ** Lumens Per Watt L0 L1 L2 L3 10W 16W 20W 26W 3000K / 82 CRI 3000K / 82 CRI 3000K / 82 CRI 3000K / 82 CRI 900lm 1250lm 1450lm 1800lm 90 78 73 69 * System wattage includes driver and LED module consumption. ** Delivered lumens will vary depending on trim, CCT, CRI, optic and ceiling thickness JOB NAME CATALOG NUMBER NOTES TYPE MX ADJUSTABLE L/M-0616:20 P-73 INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883 For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321. © 2020 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.

ELECTRICAL DATA - Intense Lighting · 35° MXG2ASTL 3.5” MX G2 LED Square Trimless Adjustable 4 1/4” 5 3/8” 12” 7 3/4” 12” NON-IC & AIR TIGHT IC DIMENSIONS Ceiling Cut

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: ELECTRICAL DATA - Intense Lighting · 35° MXG2ASTL 3.5” MX G2 LED Square Trimless Adjustable 4 1/4” 5 3/8” 12” 7 3/4” 12” NON-IC & AIR TIGHT IC DIMENSIONS Ceiling Cut

MXTG2-STLA300(1” Regress)

B W SN

Available finishes

AB WH

B W SN

Available finishes

AB WH

MXG2ASTL3.5” MX G2 LED Square Trimless Adjustable

FEATURES ■ Multiple architectural trim options ■ High center beam spot up to 24,500 CBCP

■ Dedicated 9° with field changeable 12°, 24°, 36° & 50° optics

LED LIGHT ENGINE ■ 92 CRI & 82 CRI in 2700K, 3000K, 3500K and 4100K with 2 SDCM binning

■ >50,000 hours L70 (rated life at 70% output)

ELECTRICAL SYSTEM ■ Multiple dimming drivers available ■ (Non-IC) 120V or 277V input; Power factor >.9 50/60Hz

■ (-IC) Universal 120V/277V input; Power factor >.9 50/60Hz

■ This product complies with IEEE C62.41 for surge endurance up to 2.5KV. Additional surge protection recommended. Damage from power surge is not covered by warranty.

DIMMING ■ 0-10V Dimming 1% ■ Forward/reverse dimming 1% (120V only)

■ EldoLED 0-10V 0.1% or 1% ■ Lutron® LDE1 Hi-Lume 1% EcoSystem LED driver with Soft-on, Fade-to-Black dimming technology

■ Lutron® LTEA2W Hi-Lume 1% 2-Wire LED driver (120V forward phase only)

■ DMX512 RDM 0.1%

HOUSING ■ Heavy duty black powder coated 18 gauge steel frame

■ Standard housing accommodates 5/8” ceiling thickness

■ Extended collar options available for ceilings up to 1” or 2” thick, must specify either EC1 or EC2 (EC1/EC2)

INSTALLATIONHousing types include IC Air-Tight or Non-IC Rated (must specify). Non-IC rated housings must be kept at a minimum of 3” away from insulation. Butterfly brackets are compatible with adjustable bar hangers (14”-25”) and EMT. Bar hangers must be ordered separately. Max. ambient temperature: 131°F (55°C).

TRIM SPECIFICATIONAiming with locking 35° vertical and 360° horizontal adjustment with 1/2” regress and 90° turns (90, 180, 270 and 360) with 1” regress for greater visual comfort. See fixture aiming chart on page 2. High quality trims are die-cast using A380 aluminum with durable powder coat available in multiple finishes. Perforated mesh frame is die-cast to a 0.8mm thickness to easily adhere to joint compound for seamless and trimless mounting. Trims available in 1” regress for greater visual comfort or 1/2” regress for consistent look throughout space.

EMERGENCY BACKUPRemote test switch included. External battery operates LED load at a minimum of 500 to 850 lumens for 90 minutes, depending on backup wattage selected. See trim multipliers for detailed performance. Servicing requires above ceiling access.

LISTING / WARRANTY ■ 5-Year Intense LED Limited Warranty ■ ETL listed to US and Canadian standards for damp locations

■ (-IC Only) Air-Tight Certified ASTM E283 ■ (-IC Only) ETL listed for direct contact w/insulation

■ ENERGY STAR® Qualified 1

■ Can be used to comply with 2016 Title 24, Part 6, JA8 high efficacy LED light source requirements 2

21

Housing dimensions are on Page 2

1/2”

3 1/2”

3 1/2”

1”

MXTG2-STLR300(1/2” Regress)

Notes:1. ENERGY STAR® Qualified (White reflectors only;

Excludes: L2, L3, 92 CRI & 9° options)2. Excludes: L2, L3, 82 CRI & 9° options3. L3 available with Non-IC housings only4. Available in 120V only5. Not Available in L36. Not Available in L2 & L37. DMX512 RDM not available in L0 & L18. Access above ceiling required9. Not available in L010. 9° Narrow spot not available in L2 & L3

Housing Part Number (Example: MXG2ASTL-ICL1)

Housing Installation Type Ceiling Thickness Wattage Dimming Voltage Options

MXG2ASTL -NC-IC

(Non-IC)(Air-Tight IC)

blankEC1EC2

(5/8”)(1”)(2”)

L0L1L2L33

(10W)(16W)(20W)(26W)

blankDELV4

D101ED10V15

ED10V015

LUT6

LUT24

DMXR7

(Non-Dimming)(Phase Dimming)(0-10V Dimming 1%)(eldoLED 0-10V 1%)(eldoLED 0-10V 0.1%)(Lutron® LDE1 EcoSystem 1%)(Lutron® LTEA2W 2-Wire 1%)(DMX512 RDM 0.1%)

blank

27

(Non-IC: 120V-IC: 120V/277V)(277V Non-IC Only, for -IC housing options use blank)

I100I200I400-EM78

-EM128, 9

(C-Channel Bar Hangers)(Flat Bar Hangers)(Wood Joist Bar Hangers)(7W Emergency BackupIOTA Part #ILB-CP07-A)(12W Emergency BackupIOTA Part #ILB-CP12-A)

Trim Part Number (Example: MXTG2-STLA300WL13024)

Trim Finish Wattage CCT / CRI Optic

MXTG2-STLA300 (1” Regress)MXTG2-STLR300(1/2” Regress)

BWSNABWH

(Black)(White)(Satin Nickel)(Antique Bronze)(Wheat)

L0L1L2L33

(10W)(16W)(20W)(26W)

27279303093535941419

(2700K / 82 CRI)(2700K / 92 CRI)(3000K / 82 CRI)(3000K / 92 CRI)(3500K / 82 CRI)(3500K / 92 CRI)(4100K / 82 CRI)(4100K / 92 CRI)

0910

12243650

(9° Narrow Spot)(12° Spot)(24° Narrow Flood)(36° Flood)(50° Wide Flood)

ELECTRICAL DATA

LED Light Engine System Wattage * CCT / CRI Delivered Lumens ** Lumens Per Watt

L0L1L2L3

10W16W20W26W

3000K / 82 CRI3000K / 82 CRI3000K / 82 CRI3000K / 82 CRI

900lm1250lm1450lm1800lm

90787369

* System wattage includes driver and LED module consumption.** Delivered lumens will vary depending on trim, CCT, CRI, optic and ceiling thickness

JOB NAME

CATALOG NUMBER

NOTES TYPE

MX ADJUSTABLE L/M-0616:20 P-73

INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2020 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.

Page 2: ELECTRICAL DATA - Intense Lighting · 35° MXG2ASTL 3.5” MX G2 LED Square Trimless Adjustable 4 1/4” 5 3/8” 12” 7 3/4” 12” NON-IC & AIR TIGHT IC DIMENSIONS Ceiling Cut

35°

MXG2ASTL3.5” MX G2 LED Square Trimless Adjustable

4 1/4”

5 3/8”

12”

12”7 3/4”

NON-IC & AIR TIGHT IC DIMENSIONS

Ceiling Cut Out: 4 1/8”

5/8” StandardEC1 = 1”EC2 = 2”

ACCESSORIESLuminaire will accommodate (2) accessories, accessory holder required.

INSTALLATION1. Rotate release cap by turning counter clockwise.2. Install accessories into accessory holder and replace accessory holder’s retaining clip.3. Place accessory holder and accessory flush against optic and replace release cap.

OPTICS REPLACEMENT1. Rotate release cap by turning counter clockwise.2. Install accessories into accessory holder and replace accessory holder’s retaining clip.3. Place accessory holder and accessory flush against optic and replace release cap.

Release cap

Accessory holder

Release cap

Accessories

Retainer ring

Accessory holder’s retaining clip

Optic

Module

Accessories

LH47LH47WPFLMB-47PFL1-47PFL2-47PFL4-47

(Accessory Holder, Black)(Accessory Holder, White)(Hex Louver, Black)(Prismatic Spread Lens)(Linear Spread Lens)(Soft Focus Lens)

Optics

IP-OP4712IP-OP4724IP-OP4736IP-OP4750

(12° Spot)(24° Narrow Flood)(36° Flood)(50° Wide Flood)

Plaster Frame Accommodation

Collar Type Standard EC1 EC2

Max Ceiling Thickness Up-to 5/8” Up-to 1” Up-to 2”

Fixture Aiming - Horizontal Adjustment

1” Regress Trims 90° turns 90° turns Full 360°

½” Regress Trims Full 360° Full 360° Full 360°

JOB NAME

CATALOG NUMBER

NOTES TYPE

MX ADJUSTABLE L/M-0616:20 P-74

INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2020 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.

Page 3: ELECTRICAL DATA - Intense Lighting · 35° MXG2ASTL 3.5” MX G2 LED Square Trimless Adjustable 4 1/4” 5 3/8” 12” 7 3/4” 12” NON-IC & AIR TIGHT IC DIMENSIONS Ceiling Cut

MXTG2-STLA300WL0

WL

FC

D

FC

D

LC W

L

W

D

C

D

L

W

C

L

W

CD

WL

FC

D

FC

D

LC W

L

W

D

C

D

L

W

C

L

W

CD

WL

FC

D

FC

D

LC W

L

W

D

C

D

L

W

C

L

W

CD0° HORIZONTAL 35° HORIZONTAL 35° VERTICAL

D FC W L D C FC W L D C FC W L

MXTG2-STLA300WL03000K

12° Spot

6’8’

10’12’

33819012284.4

1.31.82.22.7

1.41.82.32.7

6’8’

10’12’

4567

19811874.451

1.982.583.133.82

1.492.1

2.673.19

3’4’5’6’

4679

31719812987.9

1.151.491.892.55

2.422.963.484.24

MXTG2-STLA300WL03000K

24° Narrow Flood

6’8’

10’12’

15184.754.237.6

2.43.24

4.8

2.23

3.74.4

6’8’

10’12’

4566

87.850.632.622.7

3.24.195.226.24

2.643.354.165.03

3’4’5’6’

4578

16993.759.442.2

1.782.53.153.65

3.224.285.366.31

MXTG2-STLA300WL03000K

36° Flood

6’8’

10’12’

61.534.622.115.4

3.95.26.57.8

3.54.75.87

6’8’

10’12’

3456

39.422.114.29.8

4.66.167.679.21

3.635.016.277.48

3’4’5’6’

3567

74.642.227.819.5

2.763.464.335.13

45.346.477.64

APPLICATION DATA:

W and L are the outer points where the candle power drops to 50% of maximum. FC are the initial foot candles at the center of the beam.

W Beam widthL Beam lengthC Distance to center of beamD DistanceFC Footcandles

Candelas at Nadir

Degree Candela

0°5°15°25°35°45°

121584706428107365

3117

6233

9350

12467 10°

80°

70°

60°

50°

40°

30°20°

12° Spot (12)

Watts: 10Lumens: 857 LPW: 86 CCT: 3000K

Candelas at Nadir

Degree Candela

0°5°15°25°35°45°

541945211351165213

1380

2761

4141

5522 10°

80°

70°

60°

50°

40°

30°20°

24° Narrow Flood (24)

Watts: 10Lumens: 902 LPW: 90 CCT: 3000K

35°

35°

555

1110

1665

2220 10° 20°

36° Flood (36)

Watts: 10Lumens: 851 LPW: 85 CCT: 3000K

Candelas at Nadir

Degree Candela

0°5°15°25°35°45°

221322051313397808

80°

70°

60°

50°

40°

30°

MXTG2-STLA300WL03000K

50° Wide Flood

6’8’

10’12’

23.413.28.45.9

6.28.210.312.4

5.87.89.711.7

6’8’

10’12’

2334

17.59.86.34.4

5.767.769.6811.51

5.327.198.9710.67

3’4’5’6’

3456

33.919.112.28.5

3.464.75.846.99

4.185.56.898.2

221

442

663

884 10° 20°

50° Wide Flood (50)

Watts: 10Lumens: 726 LPW: 73 CCT: 3000K

Candelas at Nadir

Degree Candela

0°5°15°25°35°45°

84488277944518048

80°

70°

60°

50°

40°

30°

Illuminated width & length are based upon point at which illuminance falls to 50% of center illuminance. Recommended spacing is based upon uniform illuminance aiming angle is the angle between the lamp axis and the perpendicular to the illuminated plane.

Report #: ILL-02222016-01.3 (12) ILL-02222016-02.3 (24) ILL-02222016-03.3 (36) ILL-02222016-04.3 (50)

EMERGENCY MULTIPLIER: 7W Emergency (x 0.70)

CCT MULTIPLIERS: 82 CRI 92 CRI2700K (x 0.93) (x 0.76)3000K (x 1.00) (x 0.87)3500K (x 1.00) (x 0.87)4100K (x 1.00) (x 0.87)

MXTG2-STLA300Ceiling Thickness Multipliers: 5/8” Thickness (x 1.00)1” Thickness (x 0.86)2” Thickness (x 0.72)

MXTG2-STLR300Ceiling Thickness Multipliers: 5/8” Thickness (x 0.91)1” Thickness (x 0.73)2” Thickness (x 0.55)

JOB NAME

CATALOG NUMBER

NOTES TYPE

MX ADJUSTABLE L/M-0616:20 P-75

INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2020 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.

Page 4: ELECTRICAL DATA - Intense Lighting · 35° MXG2ASTL 3.5” MX G2 LED Square Trimless Adjustable 4 1/4” 5 3/8” 12” 7 3/4” 12” NON-IC & AIR TIGHT IC DIMENSIONS Ceiling Cut

MXTG2-STLA300WL1

WL

FC

D

FC

D

LC W

L

W

D

C

D

L

W

C

L

W

CD

WL

FC

D

FC

D

LC W

L

W

D

C

D

L

W

C

L

W

CD

WL

FC

D

FC

D

LC W

L

W

D

C

D

L

W

C

L

W

CD0° HORIZONTAL 35° HORIZONTAL 35° VERTICAL

D FC W L D C FC W L D C FC W L

MXTG2-STLA300WL13000K

12° Spot

6’8’

10’12’

473266170118

1.31.82.22.7

1.41.82.32.7

6’8’

10’12’

4567

27716510471.4

1.982.583.133.82

1.492.1

2.673.19

3’4’5’6’

4679

444277180123

1.151.491.892.55

2.422.963.484.24

MXTG2-STLA300WL13000K

24° Narrow Flood

6’8’

10’12’

21111975.952.7

2.43.24

4.8

2.23

3.74.4

6’8’

10’12’

4566

12370.845.731.8

3.24.195.226.24

2.643.354.165.03

3’4’5’6’

4578

23613183.159

1.782.53.153.65

3.224.285.366.31

MXTG2-STLA300WL13000K

36° Flood

6’8’

10’12’

8648.431

21.5

3.95.26.57.8

3.54.75.87

6’8’

10’12’

3456

55.131

19.813.8

4.66.167.679.21

3.635.016.277.48

3’4’5’6’

3567

10459.138.927.3

2.763.464.335.13

45.346.477.64

APPLICATION DATA:

W and L are the outer points where the candle power drops to 50% of maximum. FC are the initial foot candles at the center of the beam.

W Beam widthL Beam lengthC Distance to center of beamD DistanceFC Footcandles

Candelas at Nadir

Degree Candela

0°5°15°25°35°45°

170216589599150517

4363

8727

13090

17454 10°

80°

70°

60°

50°

40°

30°20°

12° Spot (12)

Watts: 15.4Lumens: 1205 LPW: 78 CCT: 3000K

Candelas at Nadir

Degree Candela

0°5°15°25°35°45°

758663291892231294

1933

3865

5798

7730 10°

80°

70°

60°

50°

40°

30°20°

24° Narrow Flood (24)

Watts: 15.5Lumens: 1263 LPW: 81 CCT: 3000K

35°

35°

777

1564

2330

3107 10° 20°

36° Flood (36)

Watts: 15.5Lumens: 1191 LPW: 77 CCT: 3000K

Candelas at Nadir

Degree Candela

0°5°15°25°35°45°

30983087183855511211

80°

70°

60°

50°

40°

30°

MXTG2-STLA300WL13000K

50° Wide Flood

6’8’

10’12’

32.818.511.88.2

6.28.210.312.4

5.87.89.711.7

6’8’

10’12’

2334

24.513.78.86.1

5.767.769.6811.51

5.327.198.9710.67

3’4’5’6’

3456

47.526.717.111.9

3.464.75.846.99

4.185.56.898.2

309

613

928

1237 10° 20°

50° Wide Flood (50)

Watts: 15.5Lumens: 1017 LPW: 66 CCT: 3000K

Candelas at Nadir

Degree Candela

0°5°15°25°35°45°

11811234109162325368

80°

70°

60°

50°

40°

30°

Illuminated width & length are based upon point at which illuminance falls to 50% of center illuminance. Recommended spacing is based upon uniform illuminance aiming angle is the angle between the lamp axis and the perpendicular to the illuminated plane.

Report #: ILL-02222016-01.2 (12) ILL-02222016-02.2 (24) ILL-02222016-03.2 (36) ILL-02222016-04.2 (50)

EMERGENCY MULTIPLIER: 7W Emergency (x 0.50)12W Emergency (x 0.85)

CCT MULTIPLIERS: 82 CRI 92 CRI2700K (x 0.93) (x 0.76)3000K (x 1.00) (x 0.87)3500K (x 1.00) (x 0.87)4100K (x 1.00) (x 0.87)

MXTG2-STLA300Ceiling Thickness Multipliers: 5/8” Thickness (x 1.00)1” Thickness (x 0.86)2” Thickness (x 0.72)

MXTG2-STLR300Ceiling Thickness Multipliers: 5/8” Thickness (x 0.91)1” Thickness (x 0.73)2” Thickness (x 0.55)

JOB NAME

CATALOG NUMBER

NOTES TYPE

MX ADJUSTABLE L/M-0616:20 P-76

INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2020 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.

Page 5: ELECTRICAL DATA - Intense Lighting · 35° MXG2ASTL 3.5” MX G2 LED Square Trimless Adjustable 4 1/4” 5 3/8” 12” 7 3/4” 12” NON-IC & AIR TIGHT IC DIMENSIONS Ceiling Cut

MXTG2-STLA300WL2

WL

FC

D

FC

D

LC W

L

W

D

C

D

L

W

C

L

W

CD

WL

FC

D

FC

D

LC W

L

W

D

C

D

L

W

C

L

W

CD

WL

FC

D

FC

D

LC W

L

W

D

C

D

L

W

C

L

W

CD0° HORIZONTAL 35° HORIZONTAL 35° VERTICAL

D FC W L D C FC W L D C FC W L

MXTG2-STLA300WL23000K

12° Spot

6’8’

10’12’

554312199138

1.31.82.22.7

1.41.82.32.7

6’8’

10’12’

4567

32419412283.7

1.982.583.133.82

1.492.1

2.673.19

3’4’5’6’

4679

520324211144

1.151.491.892.55

2.422.963.484.24

MXTG2-STLA300WL23000K

24° Narrow Flood

6’8’

10’12’

24713988.961.7

2.43.24

4.8

2.23

3.74.4

6’8’

10’12’

4566

14483

53.537.3

3.24.195.226.24

2.643.354.165.03

3’4’5’6’

4578

27715497.469.1

1.782.53.153.65

3.224.285.366.31

MXTG2-STLA300WL23000K

36° Flood

6’8’

10’12’

10156.736.325.2

3.95.26.57.8

3.54.75.87

6’8’

10’12’

3456

64.536.323.216.1

4.66.167.679.21

3.635.016.277.48

3’4’5’6’

3567

12269.245.632

2.763.464.335.13

45.346.477.64

APPLICATION DATA:

W and L are the outer points where the candle power drops to 50% of maximum. FC are the initial foot candles at the center of the beam.

W Beam widthL Beam lengthC Distance to center of beamD DistanceFC Footcandles

Candelas at Nadir

Degree Candela

0°5°15°25°35°45°

199397718702175598

5111

10223

15334

20446 10°

80°

70°

60°

50°

40°

30°20°

12° Spot (12)

Watts: 20.5Lumens: 1406 LPW: 69 CCT: 3000K

Candelas at Nadir

Degree Candela

0°5°15°25°35°45°

888774152216271344

2264

4528

6792

9055 10°

80°

70°

60°

50°

40°

30°20°

24° Narrow Flood (24)

Watts: 20.4Lumens: 1480 LPW: 73 CCT: 3000K

35°

35°

910

1820

2730

3640 10° 20°

36° Flood (36)

Watts: 20.5Lumens: 1395 LPW: 68 CCT: 3000K

Candelas at Nadir

Degree Candela

0°5°15°25°35°45°

36293617215365113112

80°

70°

60°

50°

40°

30°

MXTG2-STLA300WL23000K

50° Wide Flood

6’8’

10’12’

38.421.613.89.6

6.28.210.312.4

5.87.89.711.7

6’8’

10’12’

2334

28.716

10.37.2

5.767.769.6811.51

5.327.198.9710.67

3’4’5’6’

3456

55.631.320

13.9

3.464.75.846.99

4.185.56.898.2

362

725

1087

1450 10° 20°

50° Wide Flood (50)

Watts: 20.4Lumens: 1191 LPW: 58 CCT: 3000K

Candelas at Nadir

Degree Candela

0°5°15°25°35°45°

13841446127873029679

80°

70°

60°

50°

40°

30°

Illuminated width & length are based upon point at which illuminance falls to 50% of center illuminance. Recommended spacing is based upon uniform illuminance aiming angle is the angle between the lamp axis and the perpendicular to the illuminated plane.

Report #: ILL-02222016-01.1 (12) ILL-02222016-02.1 (24) ILL-02222016-03.1 (36) ILL-02222016-04.1 (50)

EMERGENCY MULTIPLIER: 7W Emergency (x 0.40)12W Emergency (x 0.68)

CCT MULTIPLIERS: 82 CRI 92 CRI2700K (x 0.93) (x 0.76)3000K (x 1.00) (x 0.87)3500K (x 1.00) (x 0.87)4100K (x 1.00) (x 0.87)

MXTG2-STLA300Ceiling Thickness Multipliers: 5/8” Thickness (x 1.00)1” Thickness (x 0.86)2” Thickness (x 0.72)

MXTG2-STLR300Ceiling Thickness Multipliers: 5/8” Thickness (x 0.91)1” Thickness (x 0.73)2” Thickness (x 0.55)

JOB NAME

CATALOG NUMBER

NOTES TYPE

MX ADJUSTABLE L/M-0616:20 P-77

INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2020 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.

Page 6: ELECTRICAL DATA - Intense Lighting · 35° MXG2ASTL 3.5” MX G2 LED Square Trimless Adjustable 4 1/4” 5 3/8” 12” 7 3/4” 12” NON-IC & AIR TIGHT IC DIMENSIONS Ceiling Cut

WL

FC

D

FC

D

LC W

L

W

D

C

D

L

W

C

L

W

CD

WL

FC

D

FC

D

LC W

L

W

D

C

D

L

W

C

L

W

CD

WL

FC

D

FC

D

LC W

L

W

D

C

D

L

W

C

L

W

CD0° HORIZONTAL 35° HORIZONTAL 35° VERTICAL

D FC W L D C FC W L D C FC W L

MXTG2-STLA300WL33000K

12° Spot

6’8’

10’12’

675380243169

1.31.82.22.7

1.41.82.32.7

6’8’

10’12’

4567

396236149102

1.982.583.133.82

1.492.1

2.673.19

3’4’5’6’

4679

635396258176

1.151.491.892.55

2.422.963.484.24

MXTG2-STLA300WL33000K

24° Narrow Flood

6’8’

10’12’

30116910875.3

2.43.24

4.8

2.23

3.74.4

6’8’

10’12’

4566

17610165.245.4

3.24.195.226.24

2.643.354.165.03

3’4’5’6’

4578

33718811984.3

1.782.53.153.65

3.224.285.366.31

MXTG2-STLA300WL33000K

36° Flood

6’8’

10’12’

12369.144.330.7

3.95.26.57.8

3.54.75.87

6’8’

10’12’

3456

78.744.328.319.7

4.66.167.679.21

3.635.016.277.48

3’4’5’6’

3567

14284.455.639

2.763.464.335.13

45.346.477.64

APPLICATION DATA:

W and L are the outer points where the candle power drops to 50% of maximum. FC are the initial foot candles at the center of the beam.

W Beam widthL Beam lengthC Distance to center of beamD DistanceFC Footcandles

MXTG2-STLA300WL3

Candelas at Nadir

Degree Candela

0°5°15°25°35°45°

2431694138562147210

6233

12467

18700

24934 10°

80°

70°

60°

50°

40°

30°20°

12° Spot (12)

Watts: 26Lumens: 1714 LPW: 66 CCT: 3000K

Candelas at Nadir

Degree Candela

0°5°15°25°35°45°

1083890422703330425

2761

5522

8282

11043 10°

80°

70°

60°

50°

40°

30°20°

24° Narrow Flood (24)

Watts: 26Lumens: 1805 LPW: 69 CCT: 3000K

35°

35°

1110

2220

3329

4439 10° 20°

36° Flood (36)

Watts: 26Lumens: 1702 LPW: 65 CCT: 3000K

Candelas at Nadir

Degree Candela

0°5°15°25°35°45°

44254411262679316015a

80°

70°

60°

50°

40°

30°

MXTG2-STLA300WL33000K

50° Wide Flood

6’8’

10’12’

46.926.416.911.7

6.28.210.312.4

5.87.89.711.7

6’8’

10’12’

2334

35.119.512.58.8

5.767.769.6811.51

5.327.198.9710.67

3’4’5’6’

3456

67.838.224.417

3.464.75.846.99

4.185.56.898.2

442

884

1326

1768 10° 20°

50° Wide Flood (50)

Watts: 26Lumens: 1452 LPW: 56 CCT: 3000K

Candelas at Nadir

Degree Candela

0°5°15°25°35°45°

16871763155889036196

80°

70°

60°

50°

40°

30°

Illuminated width & length are based upon point at which illuminance falls to 50% of center illuminance. Recommended spacing is based upon uniform illuminance aiming angle is the angle between the lamp axis and the perpendicular to the illuminated plane.

Report #: ILL-02222016-01 (12) ILL-02222016-02 (24) ILL-02222016-03 (36) ILL-02222016-04 (50)

EMERGENCY MULTIPLIER: 7W Emergency (x 0.35)12W Emergency (x 0.59)

CCT MULTIPLIERS: 82 CRI 92 CRI2700K (x 0.93) (x 0.76)3000K (x 1.00) (x 0.87)3500K (x 1.00) (x 0.87)4100K (x 1.00) (x 0.87)

MXTG2-STLA300Ceiling Thickness Multipliers: 5/8” Thickness (x 1.00)1” Thickness (x 0.86)2” Thickness (x 0.72)

MXTG2-STLR300Ceiling Thickness Multipliers: 5/8” Thickness (x 0.91)1” Thickness (x 0.73)2” Thickness (x 0.55)

JOB NAME

CATALOG NUMBER

NOTES TYPE

MX ADJUSTABLE L/M-0616:20 P-78

INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2020 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.