ELECTRIC WATER HEATERSbig and industrial CaPaCitiEs
2
HOW tO rEad tHE sYMbOls
The advantages in detail
TITANIUM PLUS
A new technology which usestitanium enamelling for greaterprotection.
NANOMIX
More quantity of hot waterthanks to special inlet pipe.
POLYURETHANEINSULATION
CFC free insulation materialaccording to the latest environ-ment requirements.
ITALIAN dESIgNGuarantee of quality.
EXTERNAL TEMPERATURE REgULATIONEasy to set a temperaturedesired.
ENAMELLEd STEEL TANkEnamelld steel tank extremelyresistant to corrosion.
IPX
This is the grade of protection certified for our products.
INSPECTION fLANgE
Large inspection flange for abetter and easier maintenance.
TBST ThermostatThe TBST Thermostat combines functional and safety devices allowing much more precise and reliable performances. Faster reaction time allows a faster hot water recovery.
The icons have been designed to facilitate the reading of the features of each product. Ariston makes it possible, from the very beginning, to quickly and easily identify performance levels, understand the different ranges and evaluatepurchasing criteria. In short, users can familiarise
themselves with each machine without becoming confused or wasting time, in line with the Ariston philosophy of always offering the customer - and the professional technician - a service which is clear and easy to use.
Extra thick insulationThere is a thick layer of high-densitypolyurethane foam which guaranteesexcellent insulation.
High-quality componentsThese are designed and manufacturedby Ariston, where very strict checkingmethods are employed so as to ensureexcellent operation, even after severalyears.
Environmentally-friendlytechnologiesAriston is committed to conciliatingindustrial procedures with the respectof environmental balances.The result of such a commitment is the elimination of chlorofluorocarbons (CFCs) from the insulation and the utmost care being taken in the selection of recyclable components.
Larger magnesium anodeThis is particularly large in size andeasy to inspect or replace, making theelectrochemical protection of the tankall the more efficient.
3
Electric water heatersbig capacity
All the product of the big capacity range are equipped with a pressure safety device to prevent overheating of the water and avoid any risk for the people or the appliance.
4
ARI 150-200
Wall hung electric storage water heater
•NODIRECTCONTACTWITHTHEWATER,
SONOLIMESCALEDEPOSITONTHE
STEATITE(DRy)HEATINgELEMENT
•EASyACCESSTOELECTRICAL
COMPONENTS
•NONEEDTODRAINTHEAPPLIANCETO
CARRyOUTOPERATIONSONTHE
HEATINgELEMENT
•LOWERHEATINgNOISE
•CONTROLLED
•gRIPHANDLES
H
GE
044
GE
044
044
Dø
H
044
Dø
ENAMELLEdSTEEL TANk
POLYURETHANE INSULATION
Technical data - Overall dimensions ARI ARI ARI ARI 150V 150H 200V 200H
Capacity l 150 150 200 200Power kW 1,8 2 2,2 2Voltage V 230 230 230 230Heating time (deltaT= 50°C) h,min 5,10 4,50 5,35 5,50Heat dispersion kWh/24h 1,41 1,87 1,85 2,07Max working temp. °C 65 75 65 75Water production (40°C) l 276 258 370 342Insulation Thickness mm 30 30 30 30Protection IP 25D 25 25D 25Weight kg 37 37 45 45
ARI ARI ARI ARI 150V 150H 200V 200H
a mm 750 750 1050 1050
b mm 500 500 800 800
c mm 1010 1010 1270 1480
d mm 230 230 230 230
e mm 175 175 175 175
f mm 560 560 560 510
g mm 575 575 575 575
h mm G3/4 G3/4 G3/4 G3/4
easyandsafe
ARI150 H ARI 150 V ARI 200 H ARI 200 V
3010190 3000060 3010191 3000061
5
ARI fS 200-250-300
floor standing electric storage water heater
•TITANIUMgLASSLINEDSTEEL
INNERTANkTESTEDAT12bAR
•5bOLTSExTRALARgE
INSPECTIONfLANgE
•OVERSIzEDMAgNESIUMANODE
•THERMOSTATWITHbIPOLAR
SAfETyDEVICE
•PRESSURESAfETyVALVETESTED
AT7bAR
•SUPPLIEDWITHSAfETyRELIEfVALVE
Technical data - Overall dimensions ARIfS ARIfS ARIfS 200 250 300 Capacity l 200 250 300 Power kW 3 3 3 Voltage V 230/400 230/400 230/400 Heating time (∆T= 45°C) h, min. 4,26 5,00 5,54 Max. Working Temp. °C 75 75 75 Heat dispersion kWh/24h 1,88 2,17 2,6 Max. Working Pressure bar 8 8 8 Insulation thickness mm 30 30 30 Protection IP 25D 25D 25D Weight kg 50 61 71
ARIfS ARIfS ARIfS 200 250 300
a mm 1320 1270 1800
b mm 560 560 560
c mm 390 365 365
ARI fS 200 ARI fS 250 ARI fS 300
3200298 3010139 3200300
ENAMELLEdSTEEL TANk
POLYURETHANE INSULATION
TEMPERATUREREgULATION
IP25d (200-300) INSPECTION fLANgE
b
a
c
ARI 200ARI 250ARI 300
floorstanding
6
TI STI 500
floor standing electric storage water heater
•bIgAMOUNTOfHOTWATER:UPTO440
LT.MIxEDAT40°CINONEDRAW
•TITANIUMgLASSLINEDSTEELINNER
TANkTESTEDAT16bAR
• 5bOLTSExTRALARgEINSPECTIONfLANgE
•OVERSIzEDMAgNESIUMANODE
•TEMPERATURECONTROL
• THERMOSTATWITHbIPOLARSAfETyDEVICE
•PRESSURESAfETyVALVETESTEDAT8bAR
•CALCIUMPROOfHEATINgELEMENT
ENAMELLEdSTEEL TANk
POLYURETHANE INSULATION
TEMPERATUREREgULATION
IP25d
Technical data - Overall dimensions TISTI500
Capacity l 500Power kW 6Voltage V 230/400Heating time (deltaT=45°C) h,min 4,40Max working temp °C 75Heat dispersion kWh/24h 3,6Max working pressure bar 8Protection IP 25DWeight kg 95
TISTI500
a mm 1870b mm 710c mm 335
TI STI 500
828016
Entrata acqua fredda G 1/2”Uscita acqua calda G 1/2”
Re-circulation Ø 3/4” G
Raccordo modello termoelettrico G 3/4”UE
Central heating return Ø 3/4” GR
DischargeS
Scarico fumi Ø 32 mmF
Central heating flow Ø 3/4” GM
T
ORIZZONTALE VERTICALE
a
d c
100 U/E
480
245
450
100300
Solar installation flow ø 1” G
Solar installation return ø 1” G
MS
RS
Ingresso gas G 3/8”G
Entrata acqua fredda G 1/2”Uscita acqua calda G 1/2”
Re-circulation Ø 3/4” G
Raccordo modello termoelettrico G 3/4”UE
Central heating return Ø 3/4” GR
DischargeS
Scarico fumi Ø 32 mmF
Central heating flow Ø 3/4” GM
T
ORIZZONTALE VERTICALE
a
d c
100 U/E
480
245
450
100300
Solar installation flow ø 1” G
Solar installation return ø 1” G
MS
RS
Ingresso gas G 3/8”G
Cold water inlet G 3/4”
LEGEND
Hot water outlet G 3/4”
bigcapacity
7
Overall dimensions Suggested Connection diagrams
H
GE
044
GE
044
044
Dø
H
044
Dø
ARI ARI 150V 200V
a mm 750 1050
b mm 500 800
c mm 1010 1270
d mm 230 230
e mm 175 175
f mm 560 560
g mm 575 575
h mm G3/4 G3/4
ARI ARI 150H 200H
a mm 750 1050
b mm 500 800
c mm 1010 1480
d mm 230 230
e mm 175 175
f mm 560 510
g mm 575 575
h mm G3/4 G3/4
A- Hot water outletB- Cold water inletC- Safety AssemblyD- Shut-off valveE- Dielectric connections
A- Hot water outletB- Cold water inletC- Safety AssemblyD- Shut-off valveE- Dielectric connections
C
D
B
50c
m5
cm
EEA
H
GE
044
GE
044
044
Dø
H
044
Dø
E
E
C
A
B
D
50 cm
b
a
c
ARIfS ARIfS ARIfS 200 250 300
a mm 1320 1270 1800
b mm 560 560 560
c mm 390 365 365
TISTI 500
a mm 1870
b mm 710
c mm 335
E
E
C
A
B
D
A- Hot water outletB- Cold water inletC- Safety AssemblyD- Shut-off valveE- Dielectric connections
Water heater connection diagrams
Assure maximum performances and absolute safety is Ariston primary concern: a proper installation of the appliance is therefore extremely important. Using the original Ariston accessories, which you can find in the following pages, as shown in the below installation schemes will help you achieving this goals.
8
ACCESSORIES
dESCRIPTION COdE
STAND for 100L to 200L
• ø 505 and 560 mm. Shift from diameter to another by turning over the stand• Rapid installation without tools. Consists of 2 rings and 4 tubes. Ring size 520mm• Height of the Ð505 water heater base from the ground = 521mm • Height of the Ð560 water heater base from the ground = 545mm • Can be equipped with stabilizer feet
3018069
LIFTING KIT FOR FLOOR STANDING MODELS
Consists of four stainless steel feet and a belt to hold the top of the appliance against the wall (except 500l model). Plinth supplied pre-assembled on fl oor standing models. This feet lift installation by 17 cm
3018044
STABILISER FEET
• Supplied in sets of four.• Adapt to fi t stand code 3018043 and the plinth of fl oor-standing model• Designed to compensate uneven fl oors 3018050
TRANSFER BRACKETS (150L and 200L)
Can be used to make up the difference between the two fi xing brackets whenthe appliance is replaced.• Installation of 150L appliance with a 500mm center distance in place of an appliance with a center distance of 230, 320, 435, 550, 800 mm• Installation of 150L and 200L appliance with an 800mm center distancein place of an appliance with a center distance of 500, 540, 700 or 790
3018051
BELTS
Ð505 and 560 mm for horizontal water heaters. Allows horizontal appliances to be installed on the fl oor or hung on the ceiling. Supplied in pairs.
ø 505ø 560
396138399004
CEILING MOUNTING KIT
To be used when the diving wall of a room can not support the weight of the appliance and as replacement for the universal tripod. Frees up space underneath the water heater
100 lt150 and 200 lt
8959303018073
QUICK RECESSING KIT
To be used when fi xing a vertical recessed water heater in a place which is diffi cult to access (small cabinet or water heater recessed among 3 walls). Make sure that the two washer in the kit are 440 mm apart (bracket center distance). Fix the top bracket into these washers.
1314450
9
dESCRIPTION COdE
THERMOSTATIC MIXING VALVE
Connection ¾”, set to 50°C 3018045
DIELECTRIC CONNECTIONS
The iron of the tank must be kept separate fron the copper of the pipes to reduce the effect of corrosive currents.• Conforms to DTU60.1
Kit 1 dielectric connection G3/4Kit 2 dielectric connections G3/4
3018071935385
OUTER INSULATING JACKET
For 300L floor standing water heaters. Provides an extra layer of top protection for appliances located outside the dwelling 343318
ELECTRIC KIT (500 LITRES)
9 kW9000W complete with 1 thermostat – 1 immersed element on tray (with screw and cable) and 1 cap
935120
12 kW12000W complete with 1 thermostat – 1 immersed element on tray (with screw and cable) and 1 cap
3018018
ELECTRIC KIT (500 LITRES)
2.5 kW/Mono-phase Protech1 fixed 2500W shielded element - 1 monophase wired active anode2 thermowells – 1 rod thermosat – 1 base unit gasket – 1 bag – 1 screw
935334
10
Electric water heatersindustrial capacities
Maximum efficiency and safety coupledin only one product. A wide and versatile rangeof electric water heaters for industrial application.Different combination of tank capacity (from 500 to 3000 lt) and electric power (from 9 kW to 36 kW) to match customer’s needs.
11
INdUSTRIAL BASIC 500 to 3000 l
Electric water heater
•EACHHEATINgELEMENTIS230V/400V TRIPHASETHEyAREMADEOfINCOLOy STAINLESSSTEEL800.•HEATINgELEMENTSfACINgDOWN TOPROVIDETHEUSERWITHAgREATER VOLUMEOfHOTWATER.•fLExIbILITy:MODULARSySTEMWHICH ALLOWSfORANEASyINCREASEIN THEPOWEROfTHEPRODUCTbyMERELy ADDINgMOREHEATINgELEMENTS.•EASyMAITENANCE:INSPECTIONfLANgE fOREASyMAINTENANCEOfTHEWATER HEATERS.•DOUbLETHERMOSTATINCLUDED(RELAy ISNOTSUPPLIED).
Technical data - Overall dimensions PERfO PERfO PERfO PERfO PERfO PERfO PERfO 500 750 1000 1500 2000 2500 3000
Capacity l 500 750 1000 1500 2000 2500 3000
Power kW 9 15 15 30 30 30 30
Heating Time h,min 4,00 3,30 4,40 3,30 4,40 5,50 7,00
Dispersions kWh/24h 7 6 6,9 9,2 10,9 12,3 14
Net weight kg 135 205 235 345 374 503 541
PERfO PERfO PERfO PERfO PERfO PERfO PERfO 500 750 1000 1500 2000 2500 3000A mm 630 790 790 1100 1100 1400 1400
B mm 730 890 890 1200 1200 1500 1500
C mm 1846 1751 2104 1880 2068 1940 2069
D mm 719 661 661 710 710 690 690
E mm 70 105 105 135 135 183 183
F mm 390 470 470 625 625 775 775
G mm 860 1020 1020 1330 1330 1630 1630
H mm 339 401 401 450 450 530 530
CW mm M1’ ½ M1’ ½ M1’ ½ M2’ M2’ M2’ M2’
HW mm M2’ M2’ M2’ M2’ M2’ M2’ M2’
R mm M1’ ¼ M1’ ¼ M1’ ¼ M1’ ¼ M1’ ¼ M1’ ¼ M1’ ¼
PERfO 500 PERfO 750 PERfO 1000 PERfO 1500 PERfO 2000 PERfO 2500 PERfO 3000
397901 397902 397903 397904 397905 397906 397907
HW- Hot water outlet 2” G (M)
R- Recirculation1”¼ G (M)
INSPECTION fLANgE
ENAMELLEd STEEL TANk
wide range ofcapacity
CW- Cold Water inlet
12
Product specifications
Product installation - Hydraulic Connections
Pressure safety device Pressure safety device dimension
Ariston industrial electric water heaters are the solution to the need of big quantities of hot water.
In the following pages there is a simple guide that shows how to:• perform hydraulic connections• choose the correct safety group depending on the specific appliance• install the components of the electric water heater• create series of electric water heaters• perform electric connections.
All the indications related to the topic above, studied and carried out by our researcher and technicians, are based on several laboratory tests and years of field experience. The aim of reccomending a specific installation process is achieving the maximum performance from the appliance while assuring to the customer maximum safety. Neverthless, please take into consideration the local regulation in force before installing the appliance.
The package includes:
9 kW version• Base for electric resistance 9 kW• Platine resistance 9 kW• Electric wire for 9 kW• Fixing screws• Pre-wired oversleeve and cap• Installation manual
15 kW and 30 kW models:• Base for electric resistance 15/30 kW• Platine resistance 15/30 kW• Electric wire for 15/30 kW• Fixing screws• Pre-wired oversleeve and cap• Installation manual
The electric water heaters of the Industrial range share the following common hydraulic layout:•Hot water outlet at the top of the tank•Cold water inlet at the bottom of the tank•Recirculation on the right-hand side•Drain at the bottom coupled with cold water inlet (please see the hydraulic installation diagram and overall dimensions for each type of appliance).
All installations have to include a PRESSURE RELIEVE safety device against:• Excess pressure in the distribution network• Excess pressure owing to a rise in temperature (expansion during heating)• Excess pressure due to the failure of a thermostat or of a contactor relay
The sizing of a hydraulic safety device depends on:• The capacity of the appliance• The power of the appliance installed
In the table aside you can find a simple choosing guide that shows the suggested pressure safety device for different capacity of the water heater. Please remember that in any case, local legislation must be complied when installing an electric appliance.
In the event of installation of appliances in series, it is necessary to install a pressurerelieve safety device for any appliance of the series, as shown in the installation diagrams in the following page.
Capacity (litres) Ø
500 1” ½
750 1” ½
1000 1” ½
1500 2”
2000 2”
2500 2”
3000 2”
HW- Hot water outlet 2” G (M)
R- Recirculation1”¼ G (M)
CW- Cold Water inlet
13
Product installation - components
Product installation - possible layouts
The components of Industrial Basic water heater should be installed following the order below:
1 Place the 3 clip nuts2 Screw the 2 or 3 anodes3 seal with 6 screw bolts4 1 plate heating element PAY ATTENTION TO PLACE THE LOOP IN THE LOWER PART5 1 mating flange + 6 nuts6 1 collar7 1 thermostat – terminal board and wiring8 1 insulating jacket9 1 cover10 1 insulating cap
for the above shown installation diagrams please consider that:
- if the pressure of the tap water is higher than 5 bars, install a pressure reducing device before the appliance and its safety accessories.- To allow water expansion, the security valve or safety group assembly should be fitted with a pipe which will allow water to flow into a funnel connected to the drains.- Under no circumstances whatsoever should this pipe be closed by means of a plug or stop valve. Plugging the pipe would lead to excess pressure and the guarantee of the appliance would not longer be valid.- The use of a filter on the cold water inlet at the bottom of the appliance is highly recommended in order to remove all impurities such as sand, gravel, mud, etc...- It is required that you install a “T” on the lower pipe of the appliance to allow a sliding valve to be fitted in order to perform a few “flushes” to get rid of any mud at the bottom of the tank.- a de-aerator with an air bleed on the hot water outlet (to evacuate all dissolved gasses) should be also used.- A inlet security group should always be installed on the water heater’s cold water inlet, respecting the flow direction indicated by the arrows on the body of the inlet security group. The inlet security group safety assembly can be replaced by a safety valve along with a non-return valve and a stop valve on the cold water inlet (as shown in the above hydraulic diagram).
NOTEThe quality of the water distribution piping is of the utmost importance. Pay attention to the connections between differing metals, we advice you to be conform with the instructions of DTU 60-1. Plan a “dielectric insulating union” near the appliance on each pipe connected to the water network.
Installation of a single water heater Installation of two water heaters in series
LEGEND*
1 cold water inlet 4 safety valve and non-return valve variant 7 non return valve 10 example of special mounting
with loop reheater2 stop valve 5 one thermostat sheat 8 water drawing points
11 funnel to the drains3 water filter 6 rapid draining valve 9 DHW pump* All the devices shown in the installation diagrams are not supplied by the manufacturer.Therefore the correct installation of the appliance in accordance with the regulation in force is complete responsability of the installer.
14
Product installation - electric connections
Star wiring formation 9 kW (Tri 400 V)(apply to Performance 500 lt only)
Star wiring formation 15 kW (Tri 400 V) (apply to all capacity Performanceequipped with 15 kW resistance)
delta wiring formation 9 kW (Tri 230 V)(apply to Performance 500 lt only)
Star wiring formation 30 kW (Tri 400 V)(apply to all capacity Performanceequipped with 30 kW resistance)
REf. TYPE CROSS-SECTION COLOUR QTY.
1 Power 6 Black 3
2 Power connection 6 Black 3
3 Earth 6 Green/yellow 2
4 Power strip 2
REf. TYPE CROSS-SECTION COLOUR QTY.
1 Commande 1.5 Red 2
2 Power 10 Black 3
3 Earth 10 Green/yellow 2
4 Power connection 6 Black 6
5 Earth connection 6 Green/yellow 6
6 Power strip 3
Individual connector 25 Green/yellow 4
L Earth connector 25 Grey 3
C Earth connector 5-6 Grey 2
REf. TYPE CROSS-SECTION COLOUR QTY.
1 Commande 1.5 Red 2
2 Power 10 Black 3
3 Earth 10 Green/yellow 2
4 Power connection 6 Black 6
5 Earth connection 6 Green/yellow 2
6 Power strip 9
Individual connector 25 Green/yellow 1
L Earth connector 25 Grey 3
C Earth connector 5-6 Grey 2
REf. TYPE CROSS-SECTION COLOUR QTY.
1 Power 6 Black 3
2 Power connection 6 Black 3
3 Earth 6 Green/yellow 2
4 Power strip 6
15
INdUSTRIAL STEATITE 500 to 1500 l
Electric water heater
• EACHHEATINgELEMENTIS230V/400V TRIPHASE.THEyHAVEASTEATITEDRy HEATINgELEMENTWITHALOWWATT DENSITy,WHICHENTAILSALOWER SURfACETEMPERATURETOkEEP MAINTENANCEDOWNTOAMINIMUM. INfACT,THEyARE“LIMESCALE-PROOf”.• HEATINgELEMENTSfACINgDOWN TOPROVIDETHEUSERWITHAgREATER VOLUMEOfHOTWATER.• fLExIbILITy:MODULARSySTEMWHICH ALLOWSfORANEASyINCREASEINTHE POWEROfTHEPRODUCTbyMERELy ADDINgMOREHEATINgELEMENTS.• EASyMAITENANCE:INSPECTIONfLANgE fOREASyMAINTENANCEOfTHEWATER HEATERS.• DOUbLETHERMOSTATINCLUDED (RELAyISNOTSUPPLIED).
Technical data - Overall dimensions PERfO PERfO PERfO PERfO PLUS500 PLUS750 PLUS1000 PLUS1500
Capacity l 500 750 1000 1500
Power kW 9 15 15 30
Heating Time h,min 4,00 3,30 4,40 3,30
Dispersions kWh/24h 7 6 6,9 9,2
Net weight kg 135 205 235 345
PERfO PERfO PERfO PERfO PLUS500 PLUS750 PLUS1000 PLUS1500A mm 630 790 790 1100
B mm 730 890 890 1200
C mm 1846 1751 2104 1880
D mm 719 661 661 710
E mm 70 105 105 135
F mm 390 470 470 625
G mm 860 1020 1020 1330
CW mm M1’ ½ M1’ ½ M1’ ½ M2’
HW mm M2’ M2’ M2’ M2’
R mm M1’ ¼ M1’ ¼ M1’ ¼ M1’ ¼
PERfO PLUS 500 PERfO PLUS 750 PERfO PLUS 1000 PERfO PLUS 1500
398210 398211 398212 398213
INSPECTION fLANgE
ENAMELLEd STEEL TANk
steatiteresistance
HW- Hot water outlet 2” G (M)
R- Recirculation1”¼ G (M)
CW- Cold Water inlet
16
Product specifications
Product installation - Hydraulic Connections
Pressure safety device Pressure safety device dimension
Ariston industrial electric water heaters are the solution to the need of big quantities of hot water.
In the following pages there is a simple guide that shows how to:• perform hydraulic connections• choose the correct safety group depending on the specific appliance• install the components of the electric water heater• create series of electric water heaters• perform electric connections.
All the indications related to the topic above, studied and carried out by our researcher and technicians, are based on several laboratory tests and years of field experience. The aim of reccomending a specific installation process is achieving the maximum performance from the appliance while assuring to the customer maximum safety. Neverthless, please take into consideration the local regulation in force before installing the appliance.
The package includes:
9 kW version•Base for electric resistance 9 kW•Steatite resistance 9 kW•Electric wire for 9 kW•Fixing screws•Oversleeve and cap• Installation Manual
15 kW and 30 kW models:•Base for electric resistance 15/30 kW•Steatite resistance 15/30 kW•Electrict wire for 15/30 kW•Fixing screws •Oversleeve and cap• Installation Manual
The electric water heaters of the Industrial range share the following common hydraulic layout:•Hot water outlet at the top of the tank•Cold water inlet at the bottom of the tank•Recirculation on the right-hand side•Drain at the bottom coupled with cold water inlet (please see the hydraulic installation diagram and overall dimensions for each type of appliance).
All installations have to include a PRESSURE RELIEVE safety device against:• Excess pressure in the distribution network• Excess pressure owing to a rise in temperature (expansion during heating)• Excess pressure due to the failure of a thermostat or of a contactor relay
The sizing of a hydraulic safety device depends on:• The capacity of the appliance• The power of the appliance installed
In the table aside you can find a simple choosing guide that shows the suggested pressure safety device for different capacity of the water heater. Please remember that in any case, local legislation must be complied when installing an electric appliance.
In the event of installation of appliances in series, it is necessary to install a pressurerelieve safety device for any appliance of the series, as shown in the installation diagrams in the following page.
HW- Hot water outlet 2” G (M)
R- Recirculation1”¼ G (M)
CW- ColdWater inlet
Capacity (litres) Ø
500 1” ½
750 1” ½
1000 1” ½
1500 2”
2000 2”
2500 2”
3000 2”
17
Product installation - components
The components of Industrial Basic water heater should be installed following the order below:
0 Place the 6 clip nuts1 Screw the 2 or 3 anodes2 1 flush seal with 6 screw bolts3 1 mating flange + 6 nuts4 1 collar5 1 thermostat sheath 6 1,2,or 3 sleeves: the mounting must be done with a tub in order to counterbalance and facilitate the screwing7 1,2 or 3 steatite heating element screwed with spanner8 1 thermostat - terminal board and wiring9 1 collar10 1 insulating jacket11 1 cover12 1 insulating cap
Product installation - possible layouts
for the above shown installation diagrams please consider that:
- if the pressure of the tap water is higher than 5 bars, install a pressure reducing device before the appliance and its safety accessories.- To allow water expansion, the security valve or safety group assembly should be fitted with a pipe which will allow water to flow into a funnel connected to the drains.- Under no circumstances whatsoever should this pipe be closed by means of a plug or stop valve. Plugging the pipe would lead to excess pressure and the guarantee of the appliance would not longer be valid.- The use of a filter on the cold water inlet at the bottom of the appliance is highly recommended in order to remove all impurities such as sand, gravel, mud, etc...- It is required that you install a “T” on the lower pipe of the appliance to allow a sliding valve to be fitted in order to perform a few “flushes” to get rid of any mud at the bottom of the tank.- a de-aerator with an air bleed on the hot water outlet (to evacuate all dissolved gasses) should be also used.- A inlet security group should always be installed on the water heater’s cold water inlet, respecting the flow direction indicated by the arrows on the body of the inlet security group. The inlet security group safety assembly can be replaced by a safety valve along with a non-return valve and a stop valve on the cold water inlet (as shown in the above hydraulic diagram).
NOTEThe quality of the water distribution piping is of the utmost importance. Pay attention to the connections between differing metals, we advice you to be conform with the instructions of DTU 60-1. Plan a “dielectric insulating union” near the appliance on each pipe connected to the water network.
Installation of a single water heater Installation of two water heaters in series
LEGEND*
1 cold water inlet 4 safety valve and non-return valve variant 7 non return valve 10 example of special mounting
with loop reheater2 stop valve 5 one thermostat sheat 8 water drawing points
11 funnel to the drains3 water filter 6 rapid draining valve 9 DHW pump* All the devices shown in the installation diagrams are not supplied by the manufacturer.Therefore the correct installation of the appliance in accordance with the regulation in force is complete responsability of the installer.
18
Product installation - electric connections
Star wiring formation 9 kW (Tri 400 V)(apply to Performance Plus 500 lt only)
Star wiring formation 15-30kW (Tri 400 V) delta wiring formation (apply to Performance Plus 750, 1000, 1500 lt)
delta wiring formation 9 kW (Tri 230 V)(apply to Performance Plus 500 lt only)
delta wiring formation 15 - 30 kW(apply to Performance Plus 750, 1000, 1500 lt)
REf. TYPE CROSS-SECTION COLOUR QTY.
1 Power 6 Black 3
2 Power connection 6 Black 3
3 Earth 6 Green/yellow 2
4 Power strip 2
REf. TYPE CROSS-SECTION COLOUR QTY.
1 Commande 1.5 Red 2
2 Power 10 Black 3
3 Earth 10 Green/yellow 2
4 Power connection 6 Black 6
5 Earth connection 6 Green/yellow 6
6 Power strip 3
Individual connector 25 Green/yellow 1
L Earth connector 25 Grey 3
C Earth connector 5-6 Grey 2
REf. TYPE CROSS-SECTION COLOUR QTY.
1 Commande 1.5 Red 2
2 Power 10 Black 3
3 Earth 10 Green/yellow 2
4 Power connection 6 Black 6
5 Earth connection 6 Green/yellow 2
6 Power strip 9
Individual connector 25 Green/yellow 1
L Earth connector 25 Grey 3
C Earth connector 5-6 Grey 2
REf. TYPE CROSS-SECTION COLOUR QTY.
1 Power 6 Black 3
2 Power connection 6 Black 3
3 Earth 6 Green/yellow 2
4 Power strip 6
19
INdUSTRIAL MULTIPOWER 500 to 3000 l
Electric water heater
•EACHHEATINgELEMENTIS230V/400V TRIPHASETHEyAREMADEOfINCOLOy STAINLESSSTEEL800.•HEATINgELEMENTSfACINgDOWN TOPROVIDETHEUSERWITHAgREATER VOLUMEOfHOTWATER.•fLExIbILITy:MODULARSySTEMWHICH ALLOWSfORANEASyINCREASEIN THEPOWEROfTHEPRODUCTbyMERELy ADDINgMOREHEATINgELEMENTS.•EASyMAITENANCE:INSPECTIONfLANgE fOREASyMAINTENANCEOfTHEWATER HEATERS.•DOUbLETHERMOSTATINCLUDED(RELAy ISNOTSUPPLIED).
Technical data - Overall dimensions MULTI MULTI MULTI MULTI MULTI MULTI MULTI MULTI MULTI 50024kW 75024kW 75036kW 100024kW 100036kW 150036kW 200036kW 250036kW 300036kW
Capacity l 500 750 750 1000 1000 1500 2000 2500 3000
Power kW 24 24 36 24 36 36 36 36 36
Heating Time h,min 1,30 2,15 1,30 3,00 1,55 3,00 3,50 5,00 5,50
Dispersions kWh/24h 7 6 6 6,9 6,9 9,2 10,9 12,3 14
Net weight kg 132 246 250 276 280 364 403 530 564
MULTI MULTI MULTI MULTI MULTI MULTI MULTI 50024kW 75024-36kW100024-36kW 150036kW 200036kW 250036kW 300036kW
A mm 630 790 790 1100 1100 1400 1400
B mm 730 890 890 1200 1200 1500 1500
C mm 1846 1751 2104 1880 2068 1940 2069
D mm 719 661 661 710 710 690 690
E mm 70 70 70 135 135 183 183
F mm 390 470 470 625 625 775 775
G mm 860 1020 1020 1320 1320 1620 1620
CW mm M1’ 1/2 M1’ 1/2 M1’ 1/2 M2’ M2’ M2’ M2’
HW mm M2’ M2’ M2’ M2’ M2’ M2’ M2’
R mm M1’ 1/4 M1’ 1/4 M1’ 1/4 M1’ 1/4 M1’ 1/4 M1’ 1/4 M1’ 1/4
INSPECTION fLANgE
ENAMELLEd STEEL TANk
multipower resistance
MULTI 500 24kW MULTI 750 24kW MULTI 750 36kW MULTI 1000 24kW MULTI 1000 36kW MULTI 1500 36kW MULTI 2000 36kW MULTI 2500 36kW MULTI 3000 36kW
397916 397918 397919 397921 397922 397924 397926 397928 397929
HW- Hot water outlet 2” G (M)
R- Recirculation1”¼ G (M)
CW- Cold Water inlet
20
Product specifications
Product installation - Hydraulic Connections
Pressure safety device Pressure safety device dimension
Ariston industrial electric water heaters are the solution to the need of big quantities of hot water.
In the following pages there is a simple guide that shows how to:• perform hydraulic connections• choose the correct safety group depending on the specific appliance• install the components of the electric water heater• create series of electric water heaters• perform electric connections.
All the indications related to the topic above, studied and carried out by our researcher and technicians, are based on several laboratory tests and years of field experience. The aim of reccomending a specific installation process is achieving the maximum performance from the appliance while assuring to the customer maximum safety. Neverthless, please take into consideration the local regulation in force before installing the appliance.
The package includes:
24 kW version•Base for electric resistance 24 kW•Platine resistance 24 kW•Electric wire for 24 kW•Fixing screws•Oversleeve and cap
36 kW models:•Base for electric resistance 36 kW•Platine resistance 36 kW•Electrict wire for 36 kW•Fixing screws •Oversleeve and cap
The electric water heaters of the Industrial range share the following common hydraulic layout:•Hot water outlet at the top of the tank•Cold water inlet at the bottom of the tank•Recirculation on the right-hand side•Drain at the bottom coupled with cold water inlet (please see the hydraulic installation diagram and overall dimensions for each type of appliance).
All installations have to include a PRESSURE RELIEVE safety device against:• Excess pressure in the distribution network• Excess pressure owing to a rise in temperature (expansion during heating)• Excess pressure due to the failure of a thermostat or of a contactor relay
The sizing of a hydraulic safety device depends on:• The capacity of the appliance• The power of the appliance installed
In the table aside you can find a simple choosing guide that shows the suggested pressure safety device for different capacity of the water heater. Please remember that in any case, local legislation must be complied when installing an electric appliance.
In the event of installation of appliances in series, it is necessary to install a pressurerelieve safety device for any appliance of the series, as shown in the installation diagrams in the following page.
HW- Hot water outlet 2” G (M)
R- Recirculation1”¼ G (M)
CW- Cold Water inlet
Capacity (litres) Ø
500 1” ½
750 1” ½
1000 1” ½
1500 2”
2000 2”
2500 2”
3000 2”
21
Product installation - components
The components of Industrial Basic water heater should be installed following the order below:
0 Place the 6 clip nuts1 Screw the 2 or 3 anodes2 1 flush seal with 6 screw bolts3 1 mating flange + 6 nuts4 1 collar5 1 thermostat sheath 6 1, 2, or 3 immersed heating elements to screw with the seal; mounting with the hand by maintaining the heating element inside the tank by the inspection opening, then tightening with spanner7 1 collar8 1 Thermostat- terminal board and wiring9 1 insulating jacket10 1 cover11 1 insulating cap
Product installation - possible layouts
for the above shown installation diagrams please consider that:
- if the pressure of the tap water is higher than 5 bars, install a pressure reducing device before the appliance and its safety accessories.- To allow water expansion, the security valve or safety group assembly should be fitted with a pipe which will allow water to flow into a funnel connected to the drains.- Under no circumstances whatsoever should this pipe be closed by means of a plug or stop valve. Plugging the pipe would lead to excess pressure and the guarantee of the appliance would not longer be valid.- The use of a filter on the cold water inlet at the bottom of the appliance is highly recommended in order to remove all impurities such as sand, gravel, mud, etc...- It is required that you install a “T” on the lower pipe of the appliance to allow a sliding valve to be fitted in order to perform a few “flushes” to get rid of any mud at the bottom of the tank.- a de-aerator with an air bleed on the hot water outlet (to evacuate all dissolved gasses) should be also used.- A inlet security group should always be installed on the water heater’s cold water inlet, respecting the flow direction indicated by the arrows on the body of the inlet security group. The inlet security group safety assembly can be replaced by a safety valve along with a non-return valve and a stop valve on the cold water inlet (as shown in the above hydraulic diagram).
NOTEThe quality of the water distribution piping is of the utmost importance. Pay attention to the connections between differing metals, we advice you to be conform with the instructions of DTU 60-1. Plan a “dielectric insulating union” near the appliance on each pipe connected to the water network.
Installation of a single water heater Installation of two water heaters in series
LEGEND*
1 cold water inlet 4 safety valve and non-return valve variant 7 non return valve 10 example of special mounting
with loop reheater2 stop valve 5 one thermostat sheat 8 water drawing points
11 funnel to the drains3 water filter 6 rapid draining valve 9 DHW pump* All the devices shown in the installation diagrams are not supplied by the manufacturer.Therefore the correct installation of the appliance in accordance with the regulation in force is complete responsability of the installer.
22
Product installation - electric connections
delta wiring formation 12 kW (Tri 400 V)(apply to all capacity Multipower equippedwith 12 kW resistance)
Star wiring formation 15-30kW (Tri 400 V) delta wiring formation (apply to Performance Plus 750, 1000, 1500 lt)
delta wiring formation 24 kW (Tri 400 V)(apply to all capacity Multipower equippedwith 24 kW resistance)
REf. TYPE CROSS-SECTION COLOUR QTY.
1 Control 1.5 Red 2
2 Power 10 Black 3
3 Earth 10 Green/yellow 2
4 Power strip 6 Black 3
5 Earth connection 6 Green/yellow 1
6 Connecting strip 6
Individual connector 25 Green/yellow 1
L Earth connector 25 Grey 3
C Earth connector 5-6 Grey 2
REf. TYPE CROSS-SECTION COLOUR QTY.
1 Control 1.5 Red 2
2 Power 10 Black 3
3 Earth 10 Green/yellow 2
4 Power trip 3
Individual connector 25 Green/yellow 1
L Earth connector 25 Grey 3
C Earth connector 5-6 Grey 2
REf. TYPE CROSS-SECTION COLOUR QTY.
1 Commande 1.5 Red 2
2 Power 10 Black 3
3 Earth 10 Green/yellow 2
4 Power connection 6 Black 3
5 Earth connection 6 Green/yellow 1
6 Power strip 6
Individual connector 25 Green/yellow 1
L Earth connector 25 Grey 3
C Earth connector 5-6 Grey 2
23
The capillary network of Ariston Technical Assistance Centres has been developed to cover the entire country, in order to guaranteeemergency and routine maintenance operations which demonstrate efficiency and a high degree of professional preparation.
A group of experts also support our Customers in the constant updating process relating to new products and technologies.
Servicewww.ariston.com
The Internet site provides operators within the sector with all theinformation which are linked to the “product catalogue”, offeringindividual details of technical features, exploded views and spare parts lists, updates for operating booklets and instruction manuals.It provides users with telephone numbers and addresses forthe relevant Assistance Centres and stockists in their local area.
Quality productsExcellent service
Aris
ton
Ther
mo
Grou
p di
scla
ims
all r
espo
nsab
ilty
for p
ossi
ble
prin
ting
or tr
ansc
riptio
n m
ista
kes
of th
is c
atal
ogue
. Fur
ther
mor
e, it
rese
rves
the
right
to c
hang
e, w
ithou
t not
ice,
the
spec
ifica
tions
and
info
rmat
ion
of th
e pr
oduc
ts c
onta
ined
her
ein.
aristOn tHErMO grOuP
ariston thermo spaViale Aristide Merloni 4560044 Fabriano (AN) ItalyPhone +39 0732 6011Fax +39 0732 602061
www.ariston.com
ariston thermo spa Middle East branchDubai Airport FreezoneOffice No. 5EA 411P.O. Box 54643 Dubai - UAEPhone +971 4 2364969Fax +971 4 2364839