274
Electric Pumps Catalogue

Electric Pumps Catalogue

Embed Size (px)

Citation preview

Page 1: Electric Pumps Catalogue

Electric Pumps Catalogue

Page 2: Electric Pumps Catalogue
Page 3: Electric Pumps Catalogue

Premier supplier of water equipmentPentair is a diversified operating company headquartered in Minnesota.Its Water Group is a global leader in providing innovative products andsystems used worldwide in the movement, treatment, storage andenjoyment of water.Pentair’s Enclosure group is leader in the global market of enclosuresfor sensitive electronics and electrical components.

Pentair is a values-driven company that brings superior products tocustomers through some of the world’s leading brands. Efforts incontinuous improvement, strong new product development, highperformance, competence, business ethics and market leadershiphave contributed greatly to our success. Pentair’s employees sharemany personal values such as accountability, deep respect for peopleand the environment, and a candid and practical work style.Strong customer relationships and quality products allow Pentair Waterto attain the vision of being the leading provider of water equipment.

Safe, clean water for people to drink andenjoy, and for industries to use

Pentair Water is playing a key role in making safe, clean water availableto an ever-growing portion of the world’s population: a valuableorganization is engaged to successfully serve our customers troughsuperior, decentralized and accountable operations and dedicated salesand marketing networks.

Pool and spaA complete line of commercialand resident ial pool /spaequipment and accessoriesincluding pumps, filters,heaters, lights, automation,automatic pool cleaners,commercial deck equipment,barbeque deck equipment,aquatic pond products andaccessories, pool tile andinterior finishing surfaces,maintenance equipment ,spa/jetted tub hydrotherapyfittings and pool/spa accessories.

Filtration & purificationTechnologiesResidential, commercial, andindustrial filtration housings;replaceable cartridge elements;carbon block filtration; drinkingwate r f i l t r a t ion sys temcomponents ; pumps forrecreational vehicles, marine,industrial applications and foodservice.

Pump SystemsProducts range from single andmultistage centrifugals tosha l low and deep we l lsubmersibles for residential,commercial and agricultureapplications; sump, effluent andsewage pumps designed forw a t e r a n d w a s t e w a t e rapplications; pressure boostingand fire fighting systems as wellas circulating pumps for heating,ventilation and air conditioning.

Water TreatmentResidential, commercial,industrial, water conditioningcontrol valves, fiberglass woundpressure tanks and vessels, brinecabinets and storage tanks.

Pentair Water operates through an organization that includes4 Business Units:

Page 4: Electric Pumps Catalogue

Water Energy

Heating, ventilationand air-conditioning

Circulator pumps for circulation of hot water in centralheating systems and circulation in domestic hot waterservice systems. Pumps for circulation of cold waterand other liquids in cooling and air-conditioning systems.

Reliable pumps providing waterenergy.Established in 1977, Nocchi is today a part of PentairWater group. For more than 30 years we have beendesigning and manufacturing water pumps providingour customers quality products and concrete solutions.Nocchi line is dedicated to engineering firms andplumbing and heating/cooling distributing centres.Within the full Nocchi range a professional customercan find products and innovative solutions to suit anyneed with regards to water supply and pressurizationin the realm of residential and commercial building,irrigation and industry applications.

Pressure boosting and fire fighting

Vertical and horizontal centrifugal pumps.Multiple pump units for transfer and boosting of water.Fire-fighting systems.

Sewage and wastewater

Drainage, effluent and sewage pumps, for a wide rangeof applications in building services.

Domestic water supply

Submersible pumps, jet pumps, multistage centrifugalpumps and compact systems for water and rain watersupply in home and garden applications.

Groundwater supplySubmersible pumps for groundwater supply, irrigationand groundwater lowering.

Page 5: Electric Pumps Catalogue

Pumps for open and drilled wellsPRATIKA MULTISTAGE CENTRIFUGAL SUBMERSIBLE PUMPS FOR CLEAR WATER

DOMINATOR 4

DOMINATOR 5

SCM 4 PLUS

SCM 4 PLUS/HF PUMP-ENDS

4” SUBMERSIBLE MOTORS

SA

SELECTION OF ELECTRIC CABLE

4’’ SUBMERSIBLE MULTISTAGE CENTRIFUGAL PUMPS FOR CLEAN WATER

SUBMERSIBLE MULTISTAGE CENTRIFUGAL PUMPS FOR CLEAR WATER

4’’ MULTISTAGE CENTRIFUGAL SUBMERSIBLE PUMPS COMPLETE WITH MOTOR

PUMP-ENDS

6’’ MULTISTAGE SUBMERSIBLE PUMPS COMPLETE WITH MOTOR

124

126

128

134

143

147

162

169

4’’ SUBMERSIBLE MOTORS

FOR SUBMERSIBLE PUMPS

SA 6” PUMP-ENDS PUMP-ENDS 167

6” MOTORS ELECTRIC MOTORS Ø 6” FOR SUBMERSIBLE PUMPS 168

SCM 4 HF 400 4’’ MULTISTAGE CENTRIFUGAL SUBMERSIBLE PUMPS COMPLETE WITH MOTOR

145

INDEX

50 HzSurface pumps

VLR VERTICAL MULTISTAGE CENTRIFUGAL PUMPS

VLRI/X

ACCESSORIES VLR/VLRI/VLRXMULTINOX-VE

DHR

MCX

MAX

MULTINOX A

JET

JET INOX

NRM

CM

CB

EP

VERTICAL MULTISTAGE CENTRIFUGAL PUMPS IN AISI 316 STAINLESS STEEL

VERTICAL MULTISTAGE CENTRIFUGAL PUMPS

MULTISTAGE CENTRIFUGAL PUMPS

MULTISTAGE CENTRIFUGAL PUMPS

20

SELF-PRIMING MULTISTAGE CENTRIFUGAL PUMPS

SELF-PRIMING MULTISTAGE CENTRIFUGAL PUMPS

SELF-PRIMING CAST IRON JET PUMPS

SELF-PRIMING STAINLESS STEEL JET PUMPS

CLOSE-COUPLED CENTRIFUGAL PUMPS. 2 AND 4 POLES

HORIZONTAL SINGLE-STAGE CENTRIFUGAL PUMPS

TWIN IMPELLER CENTRIFUGAL PUMPS

PERIPHERAL PUMPS

34

44

46

50

60

62

68

71

73

77

79

116

118

120

CONNECTIONS AND FLANGES

CPS FREQUENCY CHANGER 8

MULTINOX MULTISTAGE CENTRIFUGAL PUMPS 66

NRB

NRI

CENTRIFUGAL PUMPS WITH BASE-PLATE AND COUPLING. 2 AND 4 POLES.

BARESHAFT END-SUCTION CENTRIFUGAL PUMPS

99

115

AP DEEP SUCTION SELF-PRIMING PUMPS

DHI MULTISTAGE CENTRIFUGAL PUMPS IN AISI 316 STAINLESS STEEL 56

SSCX CLOSE-COUPLED, SINGLE-IMPELLER CENTRIFUGAL PUMP 48

K-SERIES 4” SUBMERSIBLE PUMPS COMPLETE WITH MOTOR AND CONTROL BOX 130

K-SERIES PUMP-ENDS 4” SUBMERSIBLE PUMP END 132

6TS 6" STAINLESS STEEL SUBMERSIBLE PUMPS 148

6TS PUMP-ENDS 6" PUMP-ENDS 157

Page 6: Electric Pumps Catalogue

IND

EX

INDEX

50 HzSump, sewage and effluent pumps

DRENOX SUBMERSIBLE SUMP PUMPS FOR DRAINING CLEAR WATER

OMNIA

PRIOX

MINIVORT P

MINIVORT PP

FG

SUBMERSIBLE SUMP PUMPS FOR DIRTY WATER

SUBMERSIBLE EFFLUENT VORTEX PUMPS FOR DIRTY WATER

SUBMERSIBLE SEWAGE PUMPS WITH VORTEX IMPELLER

SUBMERSIBLE SEWAGE PUMPS WITH VORTEX IMPELLER

SUBMERSIBLE PUMPS FOR WASTE WATER

178

184

187

190

192

194

DPC SUBMERSIBLE PUMP FOR DRAINING CLEAR WATER 176

DP SUBMERSIBLE PUMP FOR DRAINING CLEAR WATER 172

DPV SUBMERSIBLE PUMP FOR DRAINING DIRTY WATER 182

VACUSYSTEM MINI COLLECTION AND PUMPING STATIONS FOR WASTE WATER 210

SIMER PUMPS SUBMERSIBLE PUMP FOR DRAINING CLEAR WATER 174

Booster sets

WATERPRESS BOOSTER SET WITH ONE PUMP

233

PRESSOMAT BOOSTER SET WITH TWO PUMPS

235

HOW TO CHOOSE A BOOSTER SET

240

248

FLOW RESISTANCE TABLE

AUTOJET BOOSTER SET WITH ELECTRONIC CONTROL AND PROTECTION DEVICE

AUTOMAX BOOSTER SET WITH ELECTRONIC CONTROL AND PROTECTION DEVICE

236

238

RAINFLOW BOOSTER SYSTEM FOR HARVESTED RAINWATER 224

SWIMMEY SELF-PRIMING PUMPS FOR SWIMMING POOLS WITH PREFILTER 220

PGA - DELTA OIL SELF-PRIMING LIQUID RING PUMPS FOR DIESEL TRANSFER

VERSAILLES SUBMERSIBLE PUMPS FOR FOUNTAINS AND WATER FEATURES

228

230

BLAZE - BLAZEMASTER SINGLE AND TWIN IMPELLER ENGINE DRIVEN PUMPS 226

Pumps for special applications

ELECTRONIC CONTROL AND PROTECTION DEVICES 263

ELECTRIC PANELS 267

ACCESSORIES 276

COMPOSITE MATERIAL - STAINLESS STEEL - PAINTED STEEL 254EXPANSION TANKSVARIABLE SPEED DRIVE 258VSD

FLUSSCONTROLFLUSSCONTROL BASICAQUA TROL

CONTROL PANELS FOR SINGLE AND THREE PHASE PUMPS

PRESSURE SWITCHES, PRESSURE GAUGES, FLEXIBLE PIPES, VALVES, FLOAT SWITCHES, FILTERS

MCP HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP FOR OPERATIONS WITH SWIMMING POOL CLEANERS 222

Page 7: Electric Pumps Catalogue

JETINOXJET SELF-PRIMING CAST IRON JET PUMPS

SELF-PRIMING STAINLESS STEEL JET PUMPS7377J

50 Hz

BLAZE - BLAZEMASTER SINGLE AND TWIN IMPELLER ENGINE DRIVEN PUMPS 226B

CONTENTS IN ALPHABETIC ORDER

AACCESSORIES VLR / VLRX

27644

AQUA TROL ELECTRONIC CONTROL AND PROTECTION DEVICE 265

CONNECTIONS AND FLANGES

AUTOJET BOOSTER SET WITH ELECTRONIC CONTROL AND PROTECTION DEVICE

AUTOMAX BOOSTER SET WITH ELECTRONIC CONTROL AND PROTECTION DEVICE

236

238

ACCESSORIES PRESSURE SWITCHES, PRESSURE GAUGES, FLEXIBLE PIPES, VALVES, FLOAT SWITCHES, FILTERS

AP DEEP SUCTION SELF-PRIMING PUMPS 60

FSUBMERSIBLE PUMPS FOR WASTE WATERFG 194

ELECTRONIC CONTROL AND PROTECTION DEVICESFLUSSCONTROL/FLUSSCONTROL BASIC 263

FLOW RESISTANCE TABLE 235

ELECTRIC PANELS CONTROL PANELS FOR SINGLE AND THREE PHASE PUMPS

PERIPHERAL PUMPSEP 120

E

267

EXPANSION TANKS 255

256

STAINLESS STEEL

PAINTED STEEL

COMPOSITE MATERIAL 254

HOW TO CHOOSE A BOOSTER SET 233H

118

8

CB TWIN IMPELLER CENTRIFUGAL PUMPS

CPS FREQUENCY CHANGERC 116CM HORIZONTAL SINGLE-STAGE CENTRIFUGAL PUMPS

148157

6TS 6" STAINLESS STEEL SUBMERSIBLE PUMPS

6TS PUMP-ENDS 6" PUMP-ENDS

K-SERIES PUMP-ENDSK-SERIES 4” SUBMERSIBLE PUMPS COMPLETE WITH MOTOR AND CONTROL BOX

4” SUBMERSIBLE PUMP END130132K

DHIDHRDOMINATOR 4DOMINATOR 5

MULTISTAGE CENTRIFUGAL PUMPS

4’’ SUBMERSIBLE MULTISTAGE CENTRIFUGAL PUMPS FOR CLEAN WATER

SUBMERSIBLE MULTISTAGE CENTRIFUGAL PUMPS FOR CLEAR WATER

5650126

128

DRENOX SUBMERSIBLE SUMP PUMPS FOR DRAINING CLEAR WATER 178

MULTISTAGE CENTRIFUGAL PUMPS IN AISI 316 STAINLESS STEEL

DDP SUBMERSIBLE PUMP FOR DRAINING CLEAR WATER 172

DPC SUBMERSIBLE PUMP FOR DRAINING CLEAR WATER 176

DPV SUBMERSIBLE PUMP FOR DRAINING DIRTY WATER 182

Page 8: Electric Pumps Catalogue

CO

NT

EN

TS IN

ALP

HA

BE

TIC

OR

DE

R

CONTENTS IN ALPHABETIC ORDER

228124248

PGA - DELTAOIL SELF-PRIMING LIQUID RING PUMPS FOR DIESEL TRANSFER

PRIOX

PRATIKA

SUBMERSIBLE EFFLUENT VORTEX PUMPS FOR DIRTY WATER

MULTISTAGE CENTRIFUGAL SUBMERSIBLE PUMPS FOR CLEAR WATERP187

PRESSOMAT BOOSTER SET WITH TWO PUMPS

W WATERPRESS 240BOOSTER SET WITH ONE PUMP

50 Hz

CLOSE-COUPLED CENTRIFUGAL PUMPS. 2 AND 4 POLES

NRB7999115

NNRM

NRICENTRIFUGAL PUMPS WITH BASE-PLATE AND COUPLING. 2 AND 4 POLES.

BARESHAFT END-SUCTION CENTRIFUGAL PUMPS

O SUBMERSIBLE SUMP PUMPS FOR DIRTY WATEROMNIA 184

R RAINFLOW 224BOOSTER SYSTEM FOR HARVESTED RAINWATER

V

VACUSYSTEMVERSAILLES SUBMERSIBLE PUMPS FOR FOUNTAINS AND WATER FEATURES

210230

MINI COLLECTION AND PUMPING STATIONS FOR WASTE WATER

VLRI/X VERTICAL MULTISTAGE CENTRIFUGAL PUMPS IN AISI 316 STAINLESS STEEL

20VLR VERTICAL MULTISTAGE CENTRIFUGAL PUMPS

34

VSD VARIABLE SPEED DRIVE 258

M

MAX

MCXMINIVORT PMINIVORT PP

MULTISTAGE CENTRIFUGAL PUMPS

SUBMERSIBLE SEWAGE PUMPS WITH VORTEX IMPELLER

SUBMERSIBLE SEWAGE PUMPS WITH VORTEX IMPELLER

68

62190

192

4” SUBMERSIBLE MOTORS 147

MULTINOX AMULTINOX-VE

SELF-PRIMING MULTISTAGE CENTRIFUGAL PUMPS

VERTICAL MULTISTAGE CENTRIFUGAL PUMPS

SELF-PRIMING MULTISTAGE CENTRIFUGAL PUMPS 71

46

4’’ SUBMERSIBLE MOTORS FOR SCM4 PLUS

6” MOTORS 168ELECTRIC MOTORS Ø 6” FOR SUBMERSIBLE PUMPS

MULTINOX MULTISTAGE CENTRIFUGAL PUMPS 66

MCP 222HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP FOR OPERATIONS WITH SWIMMING POOL CLEANERS

SCM 4 PLUSSA 6’’ MULTISTAGE SUBMERSIBLE PUMPS COMPLETE WITH MOTOR

4’’ MULTISTAGE CENTRIFUGAL SUBMERSIBLE PUMPS COMPLETE WITH MOTOR162134

SSIMER PUMPS SUBMERSIBLE PUMP FOR DRAINING CLEAR WATER 174

SCM 4 PLUS/HF PUMP-ENDS PUMP-ENDS 145

SWIMMEY SELF-PRIMING PUMPS FOR SWIMMING POOLS WITH PREFILTER 220

SELECTION OF ELECTRIC CABLE FOR SUBMERSIBLE PUMPS 169

SCM 4 HF 400 4’’ MULTISTAGE CENTRIFUGAL SUBMERSIBLE PUMPS COMPLETE WITH MOTOR 143

SSCX CLOSE-COUPLED, SINGLE-IMPELLER CENTRIFUGAL PUMP 48

Page 9: Electric Pumps Catalogue

CPS energy savings control system keeps constant delivery when pressure variationsoccur. CPS is a frequency converter integrated into the pump which adjusts motorspeed so as to constantly provide users with the same pressure, even when demandfor water changes. The main applications for which CPS offers elevated comfort andbenefits are: home pressurization, irrigation, greenhouses, light industry, fountains andcreative water displays.

¥ EASY INSTALLATION¥ ENERGY SAVING¥ SILENT RUNNING¥ RELIABILITY

CPS

8

OperationThe system consists on an electric pump operated by an electronic controlsystem (speed variator) that enables the delivery of constant pressure byreducing or increasing the flow rate based on water demand.In case of an excessive system pressure decrease, the CPS starts the pumpand regulates its speed until the operating pressure is re-established. Thepump’s speed depends on water demand. If water consumption increases,the control system raises the speed of the pump up to the maximum set value.If water consumption decreases the speed of the pump is reduced up to itsminimum. If there is no further water demand the pump stops.

FREQUENCY CHANGER

Applications- Pressure boosting- Irrigation- Industrial washing equipment- Water distribution- Building

Protection devices- Dry running- Overtemperature- Overcurrent- Frost protection through ext. device

Technical features- Power input 1x230 Vac ± 10 %- Output voltage 3x230 Vac ± 10 %- Max nominal power 1,5 Kw- Input frequency 50/60 Hz + 3%- Max output current 6.5 Amp- Protection IP55 (in case of installation on motors with a protection ≥ IP55 )- Max ambient temperature +50°C- Wave type sinusoidal- Input filter In compliance with EMC directive- Pressure transmitter 0 - 5 Volt - 0 - 10 Bar- Set point 2- Connections RS 485 port- Free contacts 3 (ext set point, alarm, system inhibition)

CPS10/VLR 2B-60 ACPS10/VLR 2B-110 A

CPS10/VLR 4-80 ACPS10/VLR 8-40 A

CPS10/MULTINOX-VE 200/65

CPS10/MULTINOX-VE 200/40

CPS10/DHI 45CPS10/DHI 27

CPS10/DHR 9-40CPS10/DHR 45

CPS10/MULTINOX 80/48

CPS10/MULTINOX 120/60

CPS10/MAX 120/60CPS10/MAX 80/60

CPS10/MULTINOX-A 200/40CPS10/MULTINOX-A 200/65

VERTICAL HORIZONTAL

VersionsSELF PRIMING

Page 10: Electric Pumps Catalogue

CPS

9

50 100 150 200 250 300

20

40

60

80

100

120

Q:(L/min)

0H

(m)

0

Performance range

Control Panel

Motor speed % indicator

Line (red led)

Actual operating value indicator(pressure, frequency, current,clock, alarm)

Run (green led) /Alarm (red led)

Page selector (pressure, frequency,current, clock)

Value scrool keys

Setup indicator

Days indication

Back-light display

Indicator for setup menu

U.M.

Temperature alarm indicator

AM/PM indicator

Start/Stop/Reset

Setup and enter key

Escape/Quit key

Page 11: Electric Pumps Catalogue

AC

B50

3/4"

Ø D

E

22 22

60100156160

65

3/8"

Ø 13,5

M 10x40

Ø 1"gas

104180210

20

232

Q L / 1'm3/ h

CPS 10 / VLR

10

TABLE OF HYDRAULIC PERFORMANCE

TABLE OF SIZES AND WEIGHTS

ModelDimensions mm.

A

Weight

kg

PUMP PERFORMANCE

MODELCODEVOLTAGE

(V)Amp. Q

L/1'

m3/hHP

Dis

char

ge h

ead

in m

eter

s

B

kW

C D E

MotorPower

200

12

Hm 50 100

20

CPS 10/VLR 2B-60 A

296

386

420

CPS 10 / VLR 2B-60 A 28

CPS 10 / VLR 2B-110 A 38

CPS 10 / VLR 8-40 A 42

237

237

265

533

623

685

160

160

185

135

135

155

150 200 250

3 6 9 12 15

40

60

80

100

120

CPS 10/VLR 2B-110 A

CPS 10/VLR 4-80 A

CPS 10/VLR 8-40 A

N4700160 1CPS10/VLR 2B-60 A

N4700170

N4700150

N4700140

CPS10/VLR 2B-110 A

CPS10/VLR 4-80 A

CPS10/VLR 8-40 A

0,75 1 ~ 230 6,5

1,5 1,1 1 ~ 230 10,5

2 1,5 1 ~ 230 14,2

2 1,5 1 ~ 230 14,2 26

175

10,5

30

150

10

35

120

7,2

37

38

100

6

50

40

80

4,8

59

41

60

3,6

67

41

50

3

33

60

69

42

40

2,4

42

74

71

30

1,8

48

84

20

1,2

51

93

10

0,6

56

100

0

0

58

105

77

44

423CPS 10 / VLR 4-80 A 35265 688 185 155

DNA

1”

1”

1” 1/2

1” 1/4

DNM

1”

1”

1” 1/2

1” 1/4

Page 12: Electric Pumps Catalogue

PUMP PERFORMANCE

MODELCODEVOLTAGE

(V)Amp. Q

L/1’

m3/hHP

Dis

char

gehe

adin

met

ers

kW

MotorPower

180

10,8

N4700120 1,9CPS10/MULTINOX-VE 200/65

N4700130 CPS10/MULTINOX-VE 200/40

1,4 1 ~ 230 14,4

1,5 1,1 1 ~ 230 8,7

140

8,4

100

6

60

3,6

20

1,2

0

0

59

35

TABLE OF SIZES AND WEIGHTS

ModelDimensions mm.

A

Weight

kgDNMC D E DNA

504 37 203 232 1” 1/4 1” 1/4 25,1CPS 10 / MULTINOX-VE

438 37 143 232 1” 1/4 1” 1/4 21,2CPS 10 / MULTINOX-VE

F

220

220

G

72,5

72,5

I

145

145

B

115

115

33,7 32,1 27,6 21,5 13,1

56,1 53,4 46 35,8 21,8

11

CP

S 1

0 /

MU

LTIN

OX

- V

E

TABLE OF HYDRAULIC PERFORMANCE

CPS 10 / MULTINOX - VE

Q

Hm

L / 1'm3/ h

20

1,2

40

20

60

80

40

2,4

60

3,6

80

4,8

100

6

120

7,2

140

8,4

160

9,6

200

12

CPS 10 / MULTINOX - VE 200/65

CPS 10 / MULTINOX - VE 200/40

180

10,8

Page 13: Electric Pumps Catalogue

CPS 10 / DHI 45

CPS 10 / DHI 27

PUMP PERFORMANCE

MODELCODEVOLTAGE

(V)Amp. Q

L/1'

m3/hHP

Dis

char

gehe

adin

met

ers

kW

MotorPower

N4700080 1,25CPS 10 / DHI 45

N4700090 CPS 10 / DHI 27

0,9 1 ~ 230 10,1

1,25 0,9 1 ~ 230 10,6

0

0

43

68

10

0,6

63

20

1,2

57

30

1,8

50

40

2,4

42

43

50

3

39

35

60

3,6

36

80

4,8

33

100

6

27

120

7,2

18

26

Q L / 1'm3/ h

CPS 10 / DHI

12

TABLE OF HYDRAULIC PERFORMANCE

Hm20

10

1,2

40

2,4

60

3,6

80

4,8

100

6

120

7,2

140

8,4

20

30

40

50

60

70

80

TABLE OF SIZES AND WEIGHTS

ModelDimensions mm.

A

Weight

kgB DNMC D E DNA

105 460 141 245 232 1” 1/4 1” 1/4 17,4CPS 10 / DHI 45

CPS 10 / DHI 27

G

135

F

235

105 460 141 245 232 1” 1/4 1” 1/4 17,4135235

Page 14: Electric Pumps Catalogue

PUMP PERFORMANCE

MODELCODEVOLTAGE

(V)Amp. Q

L/1'

m3/hHP

Dis

char

gehe

adin

met

ers

kW

MotorPower

N4700030 1,74CPS 10/ DHR 9-40

N4700070 CPS 10 / DHR 45

1,3 1 ~ 230 12,5

1,5 0,9 1 ~ 230 10,6

0

0

41,5

44

40

2,4

39

60

3,6

35

80

4,8

30

100

6

35

24

120

7,2

33

17

160

9,6

27

200

12

19

240

14,4

10

260

15,6

5383940

A F

Rp 3/8Rp 3/8

EDNM

Rp 3/8

CD

DN

A

B

TABLE OF SIZES AND WEIGHTS

Model Dimensions mm. Weight

kgDNMDNA

CPS 10 / DHR 9-40

CPS 10 / DHR 45

408

445

215

225

185

155

105

65

137

190

21,1

18

A B C D E

232

232

F

1” 1/2

1” 1/4

1” 1/4

1”

100

6

150

10

200

12

250

15

300

18

10

15

20

25

30

35

40

45

50

CPS 10 / DHR 9-40

CPS 10 / DHR 45

13

CP

S 1

0 /

DH

R

TABLE OF HYDRAULIC PERFORMANCE

CPS 10 / DHR

Q

Hm

L / 1'm3/ h

50

3

5

Page 15: Electric Pumps Catalogue

Q L / 1'm3/ h

CPS 10 / MULTINOX

14

TABLE OF HYDRAULIC PERFORMANCE

Hm20

10

1,2

40

2,4

60

3,6

80

4,8

100

6

120

7,2

20

30

40

50

60

70

PUMP PERFORMANCE

MODELCODEVOLTAGE

(V)Amp. Q

L/1'

m3/hHP

Dis

char

gehe

adin

met

ers

kW

MotorPower

100

6

N4700110 0,75CPS 10 / MULTINOX 80/48

N4700100 CPS 10 / MULTINOX 120/60

0,55 1 ~ 230 6,5

1,2 0,9 1 ~ 230 8,5

80

4,8

60

3,6

40

2,4

29

46

20

1,2

37

53

0

0

48

58

20

36

8

25 4

TABLE OF SIZES AND WEIGHTS

ModelDimensions mm.

A

Weight

kgB DNMC D E DNA

389 205 171 232 138 1” 1” 13,9CPS 10 / MULTINOX 80/48

411 205 193 232 138 1” 1” 15,9CPS 10 / MULTINOX 120/60

CPS 10 / MULTINOX 80/48

CPS 10 / MULTINOX 120/60

Page 16: Electric Pumps Catalogue

15

CP

S 1

0 /

MA

X

TABLE OF HYDRAULIC PERFORMANCE

CPS 10 / MAX

Q

Hm

L / 1'm3/ h

20

1,2

10

PUMP PERFORMANCE

MODELCODEVOLTAGE

(V)Amp. Q

L/1'

m3/hHP

Dis

char

gehe

adin

met

ers

kW

MotorPower

100

6

N4700040 1,2CPS 10 / MAX 120/60

N4700060 CPS 10 / MAX 80/60

0,9 1 ~ 230 8,5

1 0,75 1 ~ 230 7

80

4,8

60

3,6

40

2,4

48

40

20

1,2

55

50

0

0

60

57

36

27

26

3

10

40

2,4

60

3,6

80

4,8

100

6

120

7,2

20

30

40

50

60

70

TABLE OF SIZES AND WEIGHTS

ModelDimensions mm.

A

Weight

kgB DNMC D E DNA

129 415 99 220 232 1” 1” 11,8CPS 10 / MAX 120/60

CPS 10 / MAX 80/60

F

165

G

182

129 415 99 220 232 1” 1” 11,8165 182

CPS 10 / MAX 120/60CPS 10 / MAX 80/60

Page 17: Electric Pumps Catalogue

PUMP PERFORMANCE

MODELCODEVOLTAGE

(V)Amp. Q

L/1’

m3/hHP

Dis

char

gehe

adin

met

ers

kW

MotorPower

N4700010 1,5CPS10/MULTINOX - A 200/40

N4700050 CPS10/MULTINOX - A 200/65

1,1 1 ~ 230 8,7

1,9 1,4 1 ~ 230 14,4

C

DNM

DN

A

A

B

D

E180

10,8

140

8,4

100

6

60

3,6

20

1,2

0

0

59

35

TABLE OF SIZES AND WEIGHTS

ModelDimensions mm.

A

Weight

kgB DNMC D E DNA

441 170 188 232 225 1” 1/4 1” 1/4 21,2CPS 10 / MULTINOX - A 200/40

497 170 243 232 225 1” 1/4 1” 1/4 24CPS 10 / MULTINOX - A 200/65

33,7 32,1 27,6 21,5 13,1

56,1 53,4 46 35,8 21,8

CPS 10 / MULTINOX - A

16

TABLE OF HYDRAULIC PERFORMANCE

CPS 10 / MULTINOX - A 200/40

CPS 10 / MULTINOX - A 200/65

Q

Hm

L / 1'm3/ h

20

1,2

40

20

60

80

40

2,4

60

3,6

80

4,8

100

6

120

7,2

140

8,4

160

9,6

200

12

180

10,8

Page 18: Electric Pumps Catalogue

VLR / VLRX / VLRIVERTICAL MULTISTAGE CENTRIFUGAL PUMPSASSEMBLED WITH ELECTRIC MOTOR

18

VERSIONS

"F" "in line" ports withROUND FLANGES

(counterflanges on request)

"A" "in line" ports withOVAL FLANGES equippedwith gas counterflanges

"V" "in line" ports withcouplings for

VICTAULIC joints

2B 4 8 16 32 66

VLR

VLR

I

VLR

X

VLR

VLR

I

VLR

X

VLR

VLR

I

VLR

X

VLR

VLR

I

VLR

X

VLR

VLR

I

VLR

X

VLR

VLR

I

VLR

X

Materials used :X = AISI 316I = AISI 304- AISI 304 hydraulic end and cast iron base

Identification NameTF4016XVLR

T = Three phaseM = Single phase

“F” "in line" round flange“A” "in line" oval flange“V” with couplings for victaulic joints

Number of stages X 10

Nominal flow in mc3/h

Model

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X X

X

X X X

X

X X

Page 19: Electric Pumps Catalogue

19

VLR

/ V

LR

X /

VLR

I

VLR / VLRX / VLRIPerformance range

300

200

10090807060

50

40

30

20

[m]H

1 2 3 4 5 6 7 8 910 20 30 40 50 60 708090100 Q [m3/h]

300

200

10090807060

50

40

30

20

[m]H

1 2 3 4 5 6 7 8 910 20 30 40 50 60 708090100 Q [m3/h]

VLR

VLRX / VLRI

VLR 8

VLR 16

VLR 4VLR 2B

VLR 32

VLR 66

VLRX 2B

VLRX 4

VLR

X 8

VLRX 16

VLRI 2B

VLRI 4

VLR

I 8

VLRI 16

Page 20: Electric Pumps Catalogue

The VLR are vertical multistage, in-line, centrifugal pumps, directly connected toan electric motor. They are not self-priming.

¥ HIGH HYDRAULIC EFFICIENCY¥ STAINLESS STEEL HYDRAULIC END¥ MOTOR DESIGNED TO EN STANDARDS

VLRVERTICAL MULTISTAGE CENTRIFUGAL PUMPS

20

Applications- Water supply- Pressure Booster Systems- Irrigation- High pressure washes- Firefighting systems- Boiler supply- Liquid transfer

Motor- Asynchronous electric motor with enclosed stator and externalventilation- Main dimensions are in accordance with DIN and IEC standards- Design: V18-up to 4,0Kw V1- to start from 5,5Kw- Class F insulation- Level of protection IP 55- Maximum environmental temperature 50 °C- Speed of rotation 2900 rpm- Increased bearings to last longer

Component

Pump casing

Motor bracket

Impeller

Diffuser

Rotating seal

Fixed seal

Material

cast ironEN GJL 200

DESIGN FEATURES

Shaft

Sleeve Stainless steel X5 CrNi 18-10 ( AISI 304 )

1

2

3 Motor joint cast ironEN GJS 400

4

5

Tungsten carbide

6

7Graphite

Stainless steel X2 CrNiMO17-12-2 ( Aisi 316 L )

Gaskets EPDM

8

9

10

Versions Available- Impeller, diffuser and outside sleeve in stainless steel- Cast iron base, adapter and motor bracket- VLR 32 and VLR 66 are equipped with cartridge mechanical seal, in order to avoid a motor disassembling in case of replacement- "A" version with oval flanges, supplied complete with counterflanges- "F" with round DIN type flanges

2

3

8

7

4

5

6

9

1

VLR 32VLR 2B - 16 VLR 66

cast ironEN GJL 500-7U

cast ironEN GJL 250

cast iron EN GJL 200

cast iron EN GJL 200

cast iron EN GJL 200

cast ironEN GJL 500-7U

cast ironEN GJL 200

Stainless steel X2 CrNiMo17-12-2 ( AISI 316L )

Stainless steel X5 CrNi 18-10 ( AISI 304 ) Stainless steel X2 CrNiMo17-12-2 ( AISI 316L )

Stainless steel X5 CrNi 18-10 ( AISI 304 ) Stainless steel X2 CrNiMo17-12-2 ( AISI 316L )

silicon carbide

Stainless steel X17 CrNi16-2 ( AISI 431 )

Stainless steel X2 CrNiMoN22-5-3 (UNS S 31803)

silicon carbide

Page 21: Electric Pumps Catalogue

21

VLR

VLR

USAGE LIMITATIONS

16 bar

VLR 2B - VLR 4

Liquid temperature

Oval flanges

Maximum operating pressure

Maximum inlet pressure

Minimum suction head

VLR 8DIN Flanges

25 bar(max temp 40°)21 bar(max temp 120°) 16 bar

16 bar

25 bar(max temp 40°)23 bar(max temp 120°)

Oval flanges DIN Flanges

-15° to +120° -15° to +120°

VLR2B/30-2VLR4/20

VLR2B/30-VLR2B/110VLR4/30-VLR4/100

VLR2B/130-VLR2B/260VLR4/120-VLR4/260

Please refer to the NPSH values with a safety margin of 0,5 m

VLR8/20-VLR8/306 bar

VLR8/40-VLR8/20010 bar

USAGE LIMITATIONS

Liquid temperature

Maximum operating pressure

Maximum inlet pressure

VLR 16 VLR 32 VLR 66DIN Flanges DIN Flanges DIN Flanges

-15° to +120° -20° to +120° -20° to +120°

Max operatingpressure

(suction included)up to VLR 66-50

16 barfrom VLR 66-60

25 bar

Max operatingpressure

(suction included)25 bar

VLR16/30-2 - VLR16/160 25 bar(max. temp. 85°)

VLR16/30-2 - VLR16/160 23 bar(max. temp. 120°)

VLR16/30-2 - VLR16/306 bar

VLR16/40 - VLR16/16010 bar

Minimum suction head Please refer to the NPSH values with a safety margin of 0,5 m

6bar

10bar

15bar

Page 22: Electric Pumps Catalogue

VLR 2B

22

- Speed of rotation 2900 rpm- Performance in accordance with UNI EN ISO 9906 standard- Head and NPSH valid for water with p=1,0 Kg / dm3 at 20° C density- The power curve (Kw) refers to the shaft power each stage- % refers to the pump hydraulic performance

For a precise selection, please refer to the performance table on next page.

VLR 2B50 Hz

TABLE OF HYDRAULIC PERFORMANCE

Page 23: Electric Pumps Catalogue

23

VLR

PUMP PERFORMANCE

VLR 2B

A1

L1

B1

50

3/4"

Ø D

H

22 22

60100156160

65

3/8"

Ø 13,5

M 10x40

Ø 1"gas

104180210

20

➊Version with oval flanges VLR 2B 30/2 - VLR 2B 150❷

TABLE OF SIZES AND WEIGHTS

L2

A2

B1

3/4"

3/8"

60100156250

3/8"

75

Ø 13,54 holes

20

104180210

n˙4 holes Ø 183/8"

32 78 100

140

➋ Version with flanges PN10 DIN 2534/ISO 7005-2❷

Ø D

H

- Type "A" : with 1" (DN 25) oval flanges. Counterflanges with 1" GAS included.- Type "F" : with 1"1/4 (DN32) round flanges. Counterflanges on request.

ModelDimensions (mm) Net Weight

(kg)

VLR 2B - 30/2VLR 2B - 30VLR 2B - 40VLR 2B - 50VLR 2B - 60VLR 2B - 70VLR 2B - 90VLR 2B - 110VLR 2B - 130VLR 2B - 150VLR 2B - 180VLR 2B - 220VLR 2B - 260

A11 L1

1 A22 L2

2B1 D H

238238256274296314350386441477

---

213213213213237237237237265265265265315

451451469487533551587623706742

---

----------

556628704

----------

821 8931019

142142142142160160160160185185185185200

109109109109131131131131130130130130140

20212325263334363743---

----------

496163

VLR 2B - 50 A M VLR 2B - 50 A T

1 ~ 230 V3 ~ 230 ÷ 400 V

VLR 2B - 30/2 A M VLR 2B - 30/2 A T

E2302102 E2301002

MODELCODE VOLTAGE Amp. µF. QL/1'

m3/h

10 20 30 40 50

17 16 13 10

kWHP

0,5 0,37

26 23 20 15 VLR 2B - 30 A M VLR 2B - 30 A T

E2302103 E2301003

1 ~ 230 V3 ~ 230 ÷ 400 V

0,6 1,2 1,8 2,4 3

18

27

34 31 26 20 VLR 2B - 40 A M VLR 2B - 40 A T

E2302104 E2301004

1 ~ 230 V3 ~ 230 ÷ 400 V

36

43 39 33 25 E2302105 E2301005

1 ~ 230 V3 ~ 230 ÷ 400 V

45

51 46 39 30 VLR 2B - 60 A M VLR 2B - 60 A T

E2302106 E2301006

1 ~ 230 V3 ~ 230 ÷ 400 V

54

60 54 46 35 VLR 2B - 70 A M VLR 2B - 70 A T

E2302107 E2301007

1 ~ 230 V3 ~ 230 ÷ 400 V

64

77 70 59 45 VLR 2B - 90 A M VLR 2B - 90 A T

E2302109 E2301009

1 ~ 230 V3 ~ 230 ÷ 400 V

82

94 85 72 55 VLR 2B - 110 A M VLR 2B - 110 A T

E2302111 E2301011

1 ~ 230 V3 ~ 230 ÷ 400 V

100

111 101 85 65 VLR 2B - 130 A M VLR 2B - 130 A T

E2302113 E2301013

1 ~ 230 V3 ~ 230 ÷ 400 V

118

128116 99 75 VLR 2B - 150 A M VLR 2B - 150 A T

E2302115 E2301015

1 ~ 230 V3 ~ 230 ÷ 400 V

136

154 139 118 90 VLR 2B - 180 F T E2331018 3 ~ 230 ÷ 400 V 163

188170 144 110 VLR 2B - 220 F T E2331022 199

222201 170 130 VLR 2B - 260 F T E2331026 235

0,5

0,75

0,75

1

1

1,5

1,5

2

2

3

3

4

0,37

0,55

0,55

0,75

0,75

1,1

1,1

1,5

1,5

2,2

2,2

3

3 ~ 230 ÷ 400 V

3 ~ 230 ÷ 400 V

2,81,7-1,0

2,81,7-1,0

4,22,6-1,5

4,22,6-1,5

53,5-2

53,5-2

7,94,5-2,6

7,94,5-2,6

10,56,1-3,5

10,56,1-3,5

8,5-4,9

8,5-4,9

11,6-6,7

16

16

16

16

25

25

31,5

31,5

36

36

Dis

char

ge h

ead

in m

eter

s

MotorPower

Page 24: Electric Pumps Catalogue

VLR 4

24

- Speed of rotation 2900 rpm- Performance in accordance with UNI EN ISO 9906 standard- Head and NPSH valid for water with p=1,0 Kg / dm3 at 20° C density- The power curve (Kw) refers to the shaft power each stage- % refers to the pump hydraulic performance

For a precise selection, please refer to the performance table on next page.

VLR 450 Hz

TABLE OF HYDRAULIC PERFORMANCE

Page 25: Electric Pumps Catalogue

25

VLR

PUMP PERFORMANCE

VLR 4

TABLE OF SIZES AND WEIGHTS

L2

A2

B1

3/4"

3/8"

60100156250

3/8"

75

Ø 13,54 holes

20

104180210

n˙4 holes Ø 183/8"

32 78 100

140

➋ Version with flanges PN10 DIN 2534/ISO 7005-2❷

Ø D

H

- Type "A" : with 1"1/4 (DN32) oval flanges. Counterflanges with 1"1/4 GAS thread included.- Type "F" : with 1"1/4 (DN32) round flanges. Counterflanges on request.

ModelDimensions (mm) Net Weight

(kg)

VLR 4 - 20VLR 4 - 30VLR 4 - 40VLR 4 - 50VLR 4 - 60VLR 4 - 80/7VLR 4 - 80VLR 4 - 100VLR 4 - 120VLR 4 - 140VLR 4 - 160VLR 4 - 190VLR 4 - 220VLR 4 - 240VLR 4 - 260

A11 L1

1 A22 L2

2B1 D H

238265

296323350423423

477531589643

-

---

213213

237237237265265

265265315315335

335385385

451478

533560587688688

742796904958

-

---

--

-----

----

749

830911965

-

---

--

---

- -

108411651298

1350

142

142160160

160185

185185185

200200200200260

260

109

109131131

131130

130130130

140140140140185

185

20

212325

2633

333637

4143---

-

-

---

--

---

--

616387

89

A1

L1

B1

50

3/4"

Ø D

H

22 22

60100156160

65

3/8"

Ø 13,5

M 10x40

Ø 11/4"gas

104180210

20

➊Version with oval flanges❷ VLR 4-20 - VLR 4-160

VLR 4 - 50 A M VLR 4 - 50 A T

1 ~ 230 V3 ~ 230 ÷ 400 V

VLR 4 - 20 A M VLR 4 - 20 A T

E3502102 E3501002

MODELCODE VOLTAGE Amp. µF. QL/1'

m3/h

40 60 80 100 120

16 15 12 9

kWHP

0,5 0,37

25 22 18 13 VLR 4 - 30 A M VLR 4 - 30 A T

E3502103 E3501003

1 ~ 230 V3 ~ 230 ÷ 400 V

2,4 3,6 4,8 6 7,2

18

27

33 29 24 18 VLR 4 - 40 A M VLR 4 - 40 A T

E3502104 E3501004

1 ~ 230 V3 ~ 230 ÷ 400 V

35

41 36 30 22 E3502105 E3501005

1 ~ 230 V3 ~ 230 ÷ 400 V

44

49 44 36 27 VLR 4 - 60 A M VLR 4 - 60 A T

E3502106 E3501006

1 ~ 230 V3 ~ 230 ÷ 400 V

53

58 51 43 31 VLR 4 - 80/7 A M VLR 4 - 80/7 A T

E3502107 E3501007

1 ~ 230 V3 ~ 230 ÷ 400 V

62

66 58 49 35 VLR 4 - 80 A M VLR 4 - 80 A T

E3502108 E3501008

1 ~ 230 V3 ~ 230 ÷ 400 V

71

82 73 61 44 VLR 4 - 100 A T E3501010 89

99 87 73 53106

115 102 85 62124

131 117 97 713 ~ 230 ÷ 400 V 142

156 138 115 84168

181 160 134 97195

0,75

1

1,5

1,5

2

2

3

3

4

4

5,5

5,5

0,55

0,75

1,1

1,1

1,5

1,5

2,2

2,2

3

3

4

4

3 ~ 230 ÷ 400 V

3 ~ 230 ÷ 400 V

7,5 5,53 ~ 400 ÷ 690 V

214 189 158 1152307,5 5,53 ~ 400 ÷ 690 V

E3501012

E3501014

E3501016

VLR 4 - 120 A T

VLR 4 - 140 A T

VLR 4 - 160 A T

3 ~ 230 ÷ 400 V

3 ~ 230 ÷ 400 V

3 ~ 230 ÷ 400 V

2,81,7-10

4,22,6-1,5

53,5-2

7,94,5-2,6

10,56,1-3,5

11,6-6,7

8,5-4,9

16

16

25

31,5

31,5

36

36

Dis

char

ge h

ead

in m

eter

s

E3531019 E3531119

E3531022 E3531122

E3531024 E3531124

E3531026 E3531126

VLR 4 - 190 F T VLR 4 - 190 F T

VLR 4 - 220 F T VLR 4 - 220 F T

VLR 4 - 240 F T VLR 4 - 240 F T

VLR 4 - 260 F T VLR 4 - 260 F T

3 ~ 400 ÷ 690 V

3 ~ 400 ÷ 690 V

3 ~ 230 ÷ 400 V

3 ~ 230 ÷ 400 V

197 175 146 106213

MotorPower

7,94,5-2,6

10,56,1-3,5

8,5-4,9

11,6-6,7

14,3-8,38,3-4,8

14,3-8,38,3-4,8

19,6-11,311,3-8,5

19,6-11,311,3-8,5

Page 26: Electric Pumps Catalogue

VLR 8

26

- Speed of rotation 2900 rpm- Performance in accordance with UNI EN ISO 9906 standard- Head and NPSH valid for water with p=1,0 Kg / dm3 at 20° C density- The power curve (Kw) refers to the shaft power each stage- % refers to the pump hydraulic performance

For a precise selection, please refer to the performance table on next page.

VLR 850 Hz

TABLE OF HYDRAULIC PERFORMANCE

Page 27: Electric Pumps Catalogue

27

VLR

PUMP PERFORMANCE

VLR 8

TABLE OF SIZES AND WEIGHTS

Ø 134 holes

20

155215246

n˙4 holes Ø 183/8"

40 88 110

150

➋ Version with flanges PN10 DIN 2534/ISO 7005-2❷

130190280

80

3/8"3/8"

A 2

L 2

Ø D3

B 1

HØ D

- Type "A" : with 1"1/2 (DN40) oval flanges. Counterflanges with 1"1/2 GAS thread included.- Type "F" : with 1"1/2 (DN40) round flanges. Counterflanges on request.

ModelDimensions (mm) Net Weight

(kg)

VLR 8 - 20VLR 8 - 30VLR 8 - 40VLR 8 - 50VLR 8 - 60VLR 8 - 80VLR 8 - 100VLR 8 - 120VLR 8 - 140VLR 8 - 160VLR 8 - 180VLR 8 - 200

A1 L1 A22 L2

2B1 D H

245375

420450480545605

665----

237237

265265265315335

335385385385385

482 612

685 715 745 860 940

1000----

--

-----

-745805865925

-

---

--

--

1130

119012501310

160

160185185

185200

200200260

260260260

131

131130130

130140

140140185

185185185

30

324042

4351

5256-

---

-

---

--

--

85

869091

11 D3

--

--

---

-300

300300300

➊ Version with oval flanges❷ VLR 8-20 - VLR 8-120

A1

L1

B1

80

3/4"

Ø D

H

27 27

130190200

100

Ø 13

M 12x45

Ø 1"1/2 gas

155215246

20

VLR 8 - 50 A T

1 ~ 230 V3 ~ 230 ÷ 400 V

VLR 8 - 20 A M VLR 8 - 20 A T

E4502102 E4501002

MODELCODE VOLTAGE Amp. µF. QL/1'

m3/h

50 100 150 175 200

19 16 14 11

kWHP

1 0,75

29 24 21 16 VLR 8 - 30 A M VLR 8 - 30 A T

E4502103 E4501003

1 ~ 230 V3 ~ 230 ÷ 400 V

3 6 9 10,5 12

21

31

38 32 27 22 VLR 8 - 40 A M VLR 8 - 40 A T

E4502104 E4501004

1 ~ 230 V3 ~ 230 ÷ 400 V

41

48 40 34 27 E4501005 3 ~ 230 ÷ 400 V 52

58 48 41 33 VLR 8 - 60 A T E4501006 62

77 64 55 44 VLR 8 - 80 A T E4501008 82

96 80 69 55 VLR 8 - 100 A T VLR 8 - 100 A T

E4501010 E4501110

3 ~ 230 ÷ 400 V3 ~ 400 ÷ 690 V

103

115 96 82 65124

134 112 96 76144

154 128 110 87165

173 144 123 98185

192 160 137 109206

1,5

2

3

3

4

5,5

5,5

7,5

7,5

10

10

1,1

1,5

2,2

2,2

3

4

4

5,5

5,5

7,5

7,5

E4501012 E4501112

E4531014 E4531114

E4531016 E4531116

E4531018 E4531118

E4531020 E4531120

VLR 8 - 120 A T VLR 8 - 120 A T

VLR 8 - 140 F T VLR 8 - 140 F T

VLR 8 - 160 F T VLR 8 - 160 F T

VLR 8 - 180 F T VLR 8 - 180 F T

VLR 8 - 200 F T VLR 8 - 200 F T

3 ~ 230 ÷ 400 V

3 ~ 230 ÷ 400 V

3 ~ 230 ÷ 400 V3 ~ 400 ÷ 690 V

3 ~ 230 ÷ 400 V3 ~ 400 ÷ 690 V

3 ~ 230 ÷ 400 V3 ~ 400 ÷ 690 V

3 ~ 230 ÷ 400 V3 ~ 400 ÷ 690 V

3 ~ 230 ÷ 400 V3 ~ 400 ÷ 690 V

53,5-2

7,94,5-2,6

10,56,1-3,5

8,5-4,9

14,3-8,38,3-4,8

8,5-4,9

11,6-6,7

25

31,5

36

Dis

char

ge h

ead

in m

eter

s

MotorPower

14,3-8,38,3-4,8

19,6-11,311,3-8,5

19,6-11,311,3-8,5

24,8-14,314,3-8,3

24,8-14,314,3-8,3

Page 28: Electric Pumps Catalogue

VLR 16

28

NPS

H (m

)

0- Speed of rotation 2900 rpm- Performance in accordance with UNI EN ISO 9906 standard- Head and NPSH valid for water with p=1,0 Kg / dm3 at 20° C density- The power curve (Kw) refers to the shaft power each stage- % refers to the pump hydraulic performance

40

60

80

100

120

140

160

180

200

220

16-30/2

16-30

16-40

16-50

16-60

16-70

16-80

16-100

16-120

16-140

16-160

4

66,6

6

100

8

133,3

10

166,6

12

200

14

233,3

16

266,6

18

300

20

333,3

22

366,6

24

400

1234567

Q

Hm

L / 1'

m3/ h 2

33,3

20

TABLE OF HYDRAULIC PERFORMANCE

40

Eff.

(%)

50

60

70

0,4

P2 (k

W)

0,5

0,6

0,7

0,8

0,9

1,0

kW

VLR 1650 Hz

2900 rpm

NPSH

Page 29: Electric Pumps Catalogue

29

VLR

PUMP PERFORMANCE

VLR 16

TABLE OF SIZES AND WEIGHTS

n 4 holes Ø18

65 102

125

165

DN 50

155

215

246

20

n 4 holesØ 13

130

190

300

90

3/8"3/8"

A

L

Ø D3

B

H

Ø D

Pump with DN50 PN25 DIN 2534 / ISO 7005-2 round flanges (with 65 mm diameter bore).Counterflanges on request.

ModelDimensions (mm) Net Weight

(kg)

VLR 16 - 30/2VLR 16 - 30VLR 16 - 40VLR 16 - 50VLR 16 - 60VLR 16 - 70VLR 16 - 80VLR 16 - 100VLR 16 - 120VLR 16 - 140VLR 16 - 160

A LB D H

460 464

509 575 620 665 710

830 92010101100

265315

335385385385385

495495495495

725 779

844 960100510501095

1325142515051595

185

200200260

260260

260260260

310310

130

140140185

185185

185185185

230230

52

56 59 82

84 90

92136140

181185

D3

140250

250300

300300300

350350

350350

E5501002

MODELCODE VOLTAGE Amp. QL/1'

m3/h

100 200 250 300 350

25 23 20 16

kWHP

3 2,2

37 34 30 24 E5501003

6 12 15 18 21

26

39

49 46 40 32 E5501004 E5501104

52

62 57 51 4065

74 69 61 4778

86 80 71 5591

98 92 81 633 ~ 230 ÷ 400 V3 ~ 400 ÷ 690 V

104

123115 101 79130

148137 121 95156

172160 142 111182

197183 162126208

4

5,5

7,5

7,5

10

10

15

15

20

20

3

4

5,5

5,5

7,5

7,5

11

11

15

15

3 ~ 230 ÷ 400 V3 ~ 400 ÷ 690 V

3 ~ 230 ÷ 400 V3 ~ 400 ÷ 690 V

3 ~ 230 ÷ 400 V3 ~ 400 ÷ 690 V

3 ~ 230 ÷ 400 V3 ~ 400 ÷ 690 V

E5501005 E5501105

E5501006 E5501106

E5501007 E5501107

E5501008 E5501108

E5501010 E5501110

E5501012 E5501112

E5501014 E5501114

E5501016 E5501116

VLR 16 - 30/2F T

VLR 16 - 30 F T

VLR 16 - 40 F T

VLR 16 - 50 F T

VLR 16 - 60 F T

VLR 16 - 70 F T

VLR 16 - 80 F T

VLR 16 - 100 F T

VLR 16 - 120 F T

VLR 16 - 140 F T

VLR 16 - 160 F T

3 ~ 230 ÷ 400 V

3 ~ 230 ÷ 400 V

3 ~ 230 ÷ 400 V3 ~ 400 ÷ 690 V

3 ~ 230 ÷ 400 V3 ~ 400 ÷ 690 V

3 ~ 230 ÷ 400 V3 ~ 400 ÷ 690 V

3 ~ 230 ÷ 400 V3 ~ 400 ÷ 690 V

24,8-14,314,3-8,3

36,3-21,021,0-12,1

36,3-21,021,0-12,1

48,4-28,028,0-12,6

48,4-28,028,0-12,6

11,6-6,7

8,5-4,9

24,8-14,314,3-8,3

19,6-11,311,3-8,5

19,6-11,311,3-8,5

14,3-8,38,3-4,8

Dis

char

ge h

ead

in m

eter

s

MotorPower

Page 30: Electric Pumps Catalogue

VLR 32

30

NPSH(m)

12

10

8

6

4

2

- Speed of rotation 2900 rpm- Performance in accordance with UNI EN ISO 9906 standard- Head and NPSH valid for water with p=1,0 Kg / dm3 at 20° C density- The power curve (Kw) refers to the shaft power each stage- % refers to the pump hydraulic performance

Q

Hm

L / 1'

m3/ h

100

6

20

40

60

80

100

120

140

160

180

200

220

240

260

200

12

300

18

400

24

500

30

600

36

700

42

P2 (W)

400

800

1200

1600

2000

Eff. (%) 10

20

30

40

50

60

70

80

32-1

32-2

32-3

32-4

32-5

32-6

32-7

32-8

32-9

32-10

32-11

32-12

32-13

32-14

kW

NPSH

TABLE OF HYDRAULIC PERFORMANCE

Page 31: Electric Pumps Catalogue

31

VLR 32

G 1/2"

Ø75

D

C

240

170

Ø18.5 Ø145

185

296

215321

B

105

A

Ø 14,5

PUMP PERFORMANCE

MODELCODE VOLTAGE Amp. QL/1'

m3/h

0

HP

150

9

200

12

600

36

3 ~ 400 ÷ 690 VVLR 32-2E6600050 35 34 33 315,5 36 278,64 1436 35 22

3 ~ 400 ÷ 690 VVLR 32-3E6600090 53 51 50 477,5 54 4110,95,5 2053 53 33

3 ~ 400 ÷ 690 VVLR 32-4E6600130 70 68 66 6310 72 5514,77,5 2771 71 44

3 ~ 400 ÷ 690 VVLR 32-5E6600170 88 85 83 7915 90 692111 3489 89 55

3 ~ 400 ÷ 690 VVLR 32-6E6600210 105 102 99 9415 107 822111 41107 106 66

3 ~ 400 ÷ 690 VVLR 32-7E6600250 123 119 116 11020 125 962915 48125 124 77

3 ~ 400 ÷ 690 VVLR 32-8E6600290 140 136 132 12620 143 1102915 54142 142 88

3 ~ 400 ÷ 690 VVLR 32-9E6600330 158 153 149 14125 161 1233518,5 61160 159 99

3 ~ 400 ÷ 690 VVLR 32-10E6600370 175 170 165 15730 179 1374222 68178 177 110

3 ~ 400 ÷ 690 VVLR 32-11E6600410 193 187 182 17330 196 1514222 75196 195 121

3 ~ 400 ÷ 690 VVLR 32-12E6600450 210 204 198 18840 214 1645530 82214 212 132

3 ~ 400 ÷ 690 VVLR 32-13E6600490 228 221 215 20440 232 1785530 88231 230 143

3 ~ 400 ÷ 690 VVLR 32-14E6600530 245 238 231 22040 250 1925530 95249 248 154

Dis

char

ge h

ead

in m

eter

s

0

350

21

400

24

250

15

300

18kW

MotorPower 500

30

700

42

2,2 718 18 113 ~ 230 ÷ 400 VVLR 32-1E6600020 18 17 17 163 18 148,65-5

TABLE OF SIZES AND WEIGHTS

ModelDimensions (mm)

A

Net Weight(Kg)

kgB C D

78

VLR 32-2 650 950 210 155 93,5

VLR 32-3 770 1160 260 200 114

VLR 32-4 840 1230 260 200 121

VLR 32-5 910 1370 260 215 153

VLR 32-6 980 1440 260 215 157,5

VLR 32-7 1050 1510 260 215 166,5

VLR 32-8 1120 1580 260 215 177,5

VLR 32-9 1190 1650 320 245 200

VLR 32-10 1260 1800 320 245 218

VLR 32-11 1330 1870 320 245 222,5

VLR 32-12 1400 1980 320 245 236

VLR 32-13 1480 2120 360 275 269

VLR 32-14 1550 2190 360 275 280

VLR 32-1 580 850 185 145

VLR

32

Page 32: Electric Pumps Catalogue

VLR 66

32

- Speed of rotation 2900 rpm- Performance in accordance with UNI EN ISO 9906 standard- Head and NPSH valid for water with p=1,0 Kg / dm3 at 20° C density- The power curve (Kw) refers to the shaft power each stage- % refers to the pump hydraulic performance

Q

Hm

L / 1'

m3/ h

240

VLR 66-80220

200

180

160

140

120

100

80

60

40

20

500

30 40 50

1000

60 70 80

1500

90

VLR 66-70

VLR 66-60

VLR 66-50

VLR 66-40

VLR 66-30

VLR 66-20

VLR 66-10

TABLE OF HYDRAULIC PERFORMANCE

P2 (kW)

7

Eff. (%)

80

70

60

5

3

kW

NPSH(m)

10

5

NPSH

Page 33: Electric Pumps Catalogue

33

VLR 66

PUMP PERFORMANCE

MODELCODE TENSION Amp. QL/1'

m3/h

0

HP

500

30

600

36

Dis

char

ge h

ead

in m

eter

s

0

1200

72

1300

78

800

48

1000

60kW

MotorPower 1417

85

5,5 25,8 24,83 ~ 400 ÷ 690 VVLR 66-10 F TE7600010 22,8 20,7 17,9 16,17,5 29,2 13,511

TABLE OF SIZES AND WEIGHTS

ModelDimensions (mm)

kW

Net Weight(Kg)

PUMP

72VLR 66-10 F T 5,5

11 55,7 54,43 ~ 400 ÷ 690 VVLR 66-20 F TE7600020 51,1 47,1 42 38,915 60,4 34,721

18,5 84,7 833 ~ 400 ÷ 690 VVLR 66-30 F TE7600030 77,7 72 64 6025 91,4 53,532

22 112,5 1103 ~ 400 ÷ 690 VVLR 66-40 F TE7600040 103,3 96 86 7930 121,6 70,840

30 140,4 1373 ~ 400 ÷ 690 VVLR 66-50 F TE7600050 129 119 107 9940 152 88,555

37 168,5 1643 ~ 400 ÷ 690 VVLR 66-60 F TE7600060 155,3 143 128 11950 182,4 106,265

45 196,5 1923 ~ 400 ÷ 690 VVLR 66-70 F TE7600070 180,7 167 150 13960 212,8 123,980

45 224,6 2193 ~ 400 ÷ 690 VVLR 66-80 F TE7600080 206,3 191 171 15960 243,2 141,680

Motor Flanges

MEC

132

PN

16

L1

574

L2

374

D1

220

D2

300

TOTAL

107

M

151

81VLR 66-20 F T 11 160 16 699 427 257 350 148194

86VLR 66-30 F T 18,5 160 16 789 532 310 350 202244

93VLR 66-40 F T 22 180 16 879 532 310 350 213244

105VLR 66-50 F T 30 200 16 969 613 354 400 237278

113VLR 66-60 F T 37 200 25 1059 613 354 400 255278

122VLR 66-70 F T 45 225 25 1149 710 411 450 341298

127VLR 66-80 F T 45 225 25 1239 710 411 450 346298

VLR

66

Counterflanges not included, available on request

Page 34: Electric Pumps Catalogue

Materials used :X = AISI 316I = AISI 304

Identification NameTF4016XVLR

T = Three phaseM = Single phase

“F” "in line" round flange“A” "in line" oval flange“V” with couplings for victaulic joints

Number of stages X 10

Nominal flow in mc3/h

Model

The VLRI / X are vertical multistage, in-line, centrifugal pumps, directly connectedto an electric motor. They are not self-priming.Entirely in AISI 304 / 316 stainless steel for sea water and special applications.

¥ HIGH HYDRAULIC EFFICIENCY¥ HYDRAULIC END IN AISI 304 (VLRI) OR AISI 316 (VLRX) STAINLESS STEEL¥ MOTOR DESIGNED TO EN STANDARDS

VLRI / XVERTICAL MULTISTAGE CENTRIFUGALPUMPS IN AISI 316 STAINLESS STEEL

34

Applications- Water supply- Pressure Booster Systems- Irrigation- High pressure washes- Firefighting systems- Boiler supply- Liquid transfer

Motor- Asynchronous electric motor with enclosed stator and external ventilation- Main dimensions are in accordance with DIN and IEC standards- Design: V18-up to 4,0Kw V1- to start from 5,5Kw- Class F insulation- Level of protection IP 55- Maximum environmental temperature 50 °C- Speed of rotation 2900 rpm- Increased bearings to last longer

Component

Base plate

Pump casing

Motor coupling

Sleeve

Impeller

Diffusers

Material

cast iron EN GJL 200Stainless steelX5CrNi 18-10 ( AISI 304 )

cast iron EN GJS 400

DESIGN FEATURES

Rotating seal

Motor bracket cast iron EN GJL 200

1

2

3 Seal guard Stainless steelX5CrNi 18-10 ( AISI 304 )

45

6

7

silicon carbide

Counterface Graphite

Shaft

8

910

11

5

10

4

3

9

6

7

8

11

2

1

VLRI VLRX

Stainless steelX2CrNiMo 17-12-3 ( AISI 316 )

Stainless steelX2CrNiMo 17-12-3 ( AISI 316 )

Stainless steelX5CrNi 18-10 ( AISI 304 )Stainless steelX5CrNi 18-10 ( AISI 304 )Stainless steelX5CrNi 18-10 ( AISI 304 )

Stainless steelX2CrNiMo 17-12-3 ( AISI 316 )

Stainless steelX2CrNiMo 17-12-3 ( AISI 316 )Stainless steelxX2CrNiMo 17-12-3 ( AISI 316 )

Stainless steel X2CrNiMo 17-12-3 ( AISI 316 )

Gaskets12 EPDM

Page 35: Electric Pumps Catalogue

35

VLR

I /

X

VLRI / X

USAGE LIMITATIONS

VLRI / X 2B

Liquid temperature

Maximum operating pressure

Maximum inlet pressure

Minimum suction head

VLRI / X 4

-15° to +120°-15° to +120°

25 bar ( max temp 40° )21 bar ( max temp 120° )

Please refer to the NPSH values with a safety margin of 0,5m

25 bar ( max temp 40° )21 bar ( max temp 120° )

VLRI / X 2B/30-2 = 6 barVLRI / X 2B/30 - VLRI / X 2B/110 10 barVLRI / X 2B/130 - VLRI / X 2B/260 15 bar

VLRI / X 4/20 - VLRI / X 4/30-2 6 barVLRI / X 4/30 - VLRI / X 4/100 10 barVLRI / X 4/120 - VLRI / X 4/260 15 bar

USAGE LIMITATIONS

Liquid temperature

Maximum operating pressure

Maximum inlet pressure

VLRI / X 8 VLRI / X 16

-15° to +120° -15° to +120°

25 bar ( max temp 40° )23 bar ( max temp 120° )

VLRI / X 16/30-2 - VLRI / X 16/160 25 bar( max temp 85° )

VLRI / X 16/30-2 - VLRI / X 16/160 23 bar( max temp 120° )

VLRI / X 8/20 - VLRI / X 8/30 6 barVLRI / X 8/40 - VLRI / X 8/200 10 bar

VLRI / X 16/30-2 - VLRI / X 16/30 6 barVLRI / X 16/40 - VLRI / X 16/160 10 bar

Minimum suction head Please refer to the NPSH values with a safety margin of 0,5m

VERSIONS

“F” “in line” portswith ROUND FLANGES

(counterflanges on request)

“A” “in line” portswith OVAL FLANGES

equipped with threadedcounterflanges

“V” “in line” portswith couplings forVICTAULIC joints

2B 4 8 16

VLR

I

VLR

X

VLR

I

VLR

X

VLR

I

VLR

X

VLR

I

VLR

X

X

X

X

X

X X

X X

VERSIONS AVAILABLE

X = Standard version• = available on request

Page 36: Electric Pumps Catalogue

VLRI / X 2B

36

- Speed of rotation 2900 rpm- Performance in accordance with UNI EN ISO 9906 standard- Head and NPSH valid for water with p=1,0 Kg / dm3 at 20° C density- The power curve (Kw) refers to the shaft power each stage- % refers to the pump hydraulic performance

For a precise selection, please refer to the performance table on next page.

VLRI / X 2B50 Hz

TABLE OF HYDRAULIC PERFORMANCE

Page 37: Electric Pumps Catalogue

37

VLR

I /

X

VLRI / X 2B

TABLE OF SIZES AND WEIGHTS

L2

A2

B1

3/4"

3/8"

60100156250

3/8"

75

Ø D

H

Ø 13,5

20

104180210

n˙4 holes Ø 183/8"

32 78 100

140

n. 4 holes

ModelDimensions (mm)

Net Weight(kg)

VLRI/X 2B - 30/2 F

VLRI/X 2B - 30 FVLRI/X 2B - 40 F

VLRI/X 2B - 50 F

VLRI/X 2B - 60 FVLRI/X 2B - 70 F

VLRI/X 2B - 90 FVLRI/X 2B - 110 F

VLRI/X 2B - 130 F

VLRI/X 2B - 150 FVLRI/X 2B - 180 F

VLRI/X 2B - 220 FVLRI/X 2B - 260 F

A LB D H

250

250268

286308326

362388

453489568

640716

215

215

215215

245245

245

245255

255280

280300

465

465

483 501

553 571

607

633 708

744 848

9201016

158

158158

158

170170

170170

180

180180

180196

168

168168

168203203

203203

205205205

205235

26

2729

31

3239

3942

43

4949

6163

VERSIONS AVAILABLE :

Type "F" : with 1" 1/4 (DN32) round flanges. Counterflanges with 1" 1/4 GAS on request.

Type "A" ( on request up to VLRI/X 2B-150 ) : with 1" 1/4 (DN32) oval flanges.

Counterflanges 1" 1/4 GAS included.

Type "V" ( on request and only on VLRX ) : with 1" 1/4 connections for Victaulic type joint.

Couplings on request.

PUMP PERFORMANCE

E2730010E2730020

E2730030E2730040

E2730050E2730060

E2730070E2730080

E2730090E2730100

E2730110E2730120

E2730130E2730140

E2730150E2730160

E2730170E2730180

E2730190E2730200

E2730210

E2730220

E2730230

0,37

0,37

0,55

0,55

0,75

0,75

1,10

1,10

1,50

1,50

2,20

2,20

3,00

0,50

0,50

0,75

0,75

1,00

1,00

1,50

1,50

2,00

2,00

3,00

3,00

4,00

1 ~ 230 V3 ~ 230÷400 V

1 ~ 230 V3 ~ 230÷400 V

1 ~ 230 V3 ~ 230÷400 V

1 ~ 230 V3 ~ 230÷400 V

1 ~ 230 V3 ~ 230÷400 V

1 ~ 230 V3 ~ 230÷400 V

1 ~ 230 V3 ~ 230÷400 V

1 ~ 230 V3 ~ 230÷400 V

1 ~ 230 V3 ~ 230÷400 V

1 ~ 230 V3 ~ 230÷400 V

3 ~ 230÷400 V

3 ~ 230÷400 V

3 ~ 230÷400 V

VLRI/X 2B- 30/2 F MVLRI/X 2B- 30/2 F T

VLRI/X 2B- 30 F MVLRI/X 2B- 30 F T

VLRI/X 2B- 40 F MVLRI/X 2B- 40 F T

VLRI/X 2B- 50 F MVLRI/X 2B- 50 F T

VLRI/X 2B- 60 F MVLRI/X 2B- 60 F T

VLRI/X 2B- 70 F MVLRI/X 2B- 70 F T

VLRI/X 2B- 90 F MVLRI/X 2B- 90 F T

VLRI/X 2B-110 F MVLRI/X 2B-110 F T

VLRI/X 2B-130 F MVLRI/X 2B-130 F T

VLRI/X 2B-150 F MVLRI/X 2B-150 F T

VLRI/X 2B-180 F T

VLRI/X 2B-220 F T

VLRI/X 2B-260 F T

2,81,7 - 1

2,81,7 - 1

4,22,6 - 1,5

53,5 - 2

7,94,5 - 2,6

10,56,1 - 3,5

8,5 - 4,9

8,5 - 4,9

11,6 - 6,7

16

16

16

16

25

25

31,5

31,5

36

36

CODEVLRX

MODELMotorPower

kWHPVOLTAGE Amp. µF.

Dis

char

ge h

ead

in m

eter

s

18 17 16 13 10

27 26 23 20 15

36 34 31 26 20

45 43 39 33 25

54 51 46 39 30

64 60 54 46 35

82 77 70 59 45

100 94 85 72 55

118 111 101 85 65

136 128 116 99 75

163 154 139 118 90

199 188 170 144 110

235 222 201 170 130

E2400010E2400020

E2400030E2400040

E2400050E2400060

E2400070E2400080

E2400090E2400100

E2400110E2400120

E2400130E2400140

E2400150E2400160

E2400170E2400180

E2400190E2400200

E2400210

E2400220

E2400230

CODEVLRI

QL/1'

m3/h

10 20 30 40 50

3,02,41,81,20,6

4,22,6 - 1,5

53,5 - 2

7,94,5 - 2,6

10,56,1 - 3,5

Page 38: Electric Pumps Catalogue

VLRI / X 4

38

- Speed of rotation 2900 rpm- Performance in accordance with UNI EN ISO 9906 standard- Head and NPSH valid for water with p=1,0 Kg / dm3 at 20° C density- The power curve (Kw) refers to the shaft power each stage- % refers to the pump hydraulic performance

For a precise selection, please refer to the performance table on next page.

VLRI / X 450 Hz

TABLE OF HYDRAULIC PERFORMANCE

Page 39: Electric Pumps Catalogue

VERSION AVAILABLE:Type F : with 1 1/4 (DN32) round flanges. Counterflanges with 1 1/4 GAS thread on request.Type A (on request up to VLRI/X 4-160): with 1 1/4 (DN32) oval flanges.Counterflanges with 1 1/4 GAS thread included.Type V (on request and only on VLRX): with 1 1/4 connections for Victaulic type joint.Couplings on request.

39

VLR

I /

X

VLRI / X 4

TABLE OF SIZES AND WEIGHTS

Model Dimensions (mm)Net Weight

(kg)

VLRI/X 4 - 20 FVLRI/X 4 - 30 F

VLRI/X 4 - 40 F

VLRI/X 4 - 50 FVLRI/X 4 - 60 FVLRI/X 4 - 80/7 FVLRI/X 4 - 80 F

VLRI/X 4 - 100 FVLRI/X 4 - 120 F

VLRI/X 4 - 140 FVLRI/X 4 - 160 FVLRI/X 4 - 190 FVLRI/X 4 - 220 FVLRI/X 4 - 240 FVLRI/X 4 - 260 F

A LB D H

250277

308335

362435

435

489543

601655

761842923977

215215

245245

245255255

280280

300300325325390390

465 492

553 580

607 690 690

769 823

901 9551086116713131367

158158

170170

170180180

180180

196196218218300300

168168203

203

203205

205205

205

235235

256256350350

2627

2931

323939

4243

494961638789

L2

A2

B1

3/4"

3/8"

60100156250

3/8"

75

Ø D

H

Ø 13,5

20

104180210

n˙4 holes Ø 183/8"

32 78 100

140

n. 4 holes

PUMP PERFORMANCE

E3730010E3730020

E3730030E3730040

E3730050E3730060

E3730070E3730080

E3730090E3730100

E3730110E3730120

E3730130E3730140

E3730150

E3730160

E3730170

E3730180

E3730190E3730250E3730200E3730260E3730210E3730230

E3730220E3730240

0,37

0,55

0,75

1,10

1,10

1,50

1,50

2,20

2,20

3,00

3,00

4,00

4,00

5,50

5,50

1 ~ 230 V3 ~ 230÷400 V

1 ~ 230 V3 ~ 230÷400 V

1 ~ 230 V3 ~ 230÷400 V

1 ~ 230 V3 ~ 230÷400 V

1 ~ 230 V3 ~ 230÷400 V

1 ~ 230 V3 ~ 230÷400 V

1 ~ 230 V3 ~ 230÷400 V

3 ~ 230÷400 V

3 ~ 230÷400 V

3 ~ 230÷400 V

3 ~ 230÷400 V

3 ~ 230÷400 V3 ~ 400÷690 V3 ~ 230÷400 V3 ~ 400÷690 V

3 ~ 230÷400 V3 ~ 400÷690 V

3 ~ 230÷400 V3 ~ 400÷690 V

VLRI/X 4- 20 F MVLRI/X 4- 20 F T

VLRI/X 4- 30 F MVLRI/X 4- 30 F T

VLRI/X 4- 40 F MVLRI/X 4- 40 F T

VLRI/X 4- 50 F MVLRI/X 4- 50 F T

VLRI/X 4- 60 F MVLRI/X 4- 60 F T

VLRI/X 4- 80/7 F MVLRI/X 4- 80/7 F T

VLRI/X 4- 80 F MVLRI/X 4- 80 F T

VLRI/X 4-100 F T

VLRI/X 4-120 F T

VLRI/X 4-140 F T

VLRI/X 4-160 F T

VLRI/X 4-190 F TVLRI/X 4-190 F T

VLRI/X 4-220 F TVLRI/X 4-220 F T

VLRI/X 4-240 F TVLRI/X 4-240 F T

VLRI/X 4-260 F TVLRI/X 4-260 F T

2,81,7 - 1,0

4,22,6 - 1,5

53,5 - 2

7,94,5 - 2,6

7,94,5 - 2,6

10,56,1 - 3,5

10,56,1 - 3,5

8,5 - 4,9

8,5 - 4,9

11,6 - 6,7

11,6 - 6,7

14,3 - 8,3

16

16

25

31,5

31,5

36

36

0,50

0,75

1,00

1,50

1,50

2,00

2,00

3,00

3,00

4,00

4,00

5,50

5,50

7,50

7,50

CODEVLRX

MODEL

MotorPower

kWHPVOLTAGE Amp. F

Dis

char

ge h

ead

in m

eter

s

18 16 15 12 9

27 25 22 18 13

35 33 29 24 18

44 41 36 30 22

53 49 44 36 27

62 58 51 43 31

71 66 58 49 35

89 82 73 61 44

106 99 87 73 53

124 115 102 85 62

142 131 117 97 71

168 156 138 115 84

195 181 160 134 97

213 197 175 146 106

230 214 189 158 115

E3600010E3600020

E3600030E3600040

E3600050E3600060

E3600070E3600080

E3600090E3600100

E3600110E3600120

E3600130E3600140

E3600150

E3600160

E3600170

E3600180

E3600190E3600250E3600200E3600260E3600210E3600230

E3600220E3600240

CODEVLRI

QL/1’

m3/h

40 60 80 100 120

7,26,04,83,62,4

8,3 - 4,8

14,3 - 8,38,3 - 4,8

19,6 - 11,311,3 - 8,5

19,6 - 11,311,3 - 8,5

Page 40: Electric Pumps Catalogue

VLRI / X 8

40

- Speed of rotation 2900 rpm- Performance in accordance with UNI EN ISO 9906 standard- Head and NPSH valid for water with p=1,0 Kg / dm3 at 20° C density- The power curve (Kw) refers to the shaft power each stage- % refers to the pump hydraulic performance

For a precise selection, please refer to the performance table on next page.

VLRI / X 850 Hz

TABLE OF HYDRAULIC PERFORMANCE

Page 41: Electric Pumps Catalogue

41

VLR

I /

X

VLRI / X 8

TABLE OF SIZES AND WEIGHTS

215245

Ø19

Ø48

Ø86

,5

Ø11

0

Ø15

0

1B

VERSIONS AVAILABLE :

Type "F" : with 1" 1/2 (DN40) round flanges. Counterflanges with 1" 1/2 GAS thread on request.

Type "V" ( on request and only on VLRX ) : with 2" connections for Victaulic type joint.

Couplings on request.

130190280

80

3/8"3/8"

A 2

L 2

Ø D3

B 1

HØ D

ModelDimensions (mm)

NetWeight

(kg)

VLRI/X 8 - 20 FVLRI/X 8 - 30 FVLRI/X 8 - 40 FVLRI/X 8 - 50 FVLRI/X 8 - 60 FVLRI/X 8 - 80 FVLRI/X 8 - 100 FVLRI/X 8 - 120 FVLRI/X 8 - 140 FVLRI/X 8 - 160 FVLRI/X 8 - 180 FVLRI/X 8 - 200 F

A LB D H

237237

265265265315335

335385385385385

245375

420450480545605

665745805865925

422

612685715

745860

94010001130

119012501310

160

160185185

185200

200200260

260260260

131

131130130

130140

140140185

185185185

33

354345

4654

555980

818586

D3

--

--

---

-300

300300300

E4730010 E4730020

E4730030 E4730040 E4730050 E4730060

E4730070

E4730080

E4730090

E4730100 E4730110

E4730120 E4730130

E4730140 E4730150

E4730160 E4730170

E4730180 E4730190

E4730200 E4730210

VLRI/X 8 - 50 F T

VLRI/X 8 - 20 F M VLRI/X 8 - 20 F T

VLRI/X 8 - 30 F M VLRI/X 8 - 30 F T VLRI/X 8 - 40 F M VLRI/X 8 - 40 F T

VLRI/X 8 - 60 F T

VLRI/X 8 - 80 F T

VLRI/X 8 - 100 F T VLRI/X 8 - 100 F T

VLRI/X 8 - 120 F T VLRI/X 8 - 120 F T

VLRI/X 8 - 140 F T VLRI/X 8 - 140 F T

VLRI/X 8 - 160 F T VLRI/X 8 - 160 F T

VLRI/X 8 - 180 F T VLRI/X 8 - 180 F T

VLRI/X 8 - 200 F T VLRI/X 8 - 200 F T

1

1,5

2

3

3

4

5,5

5,5

7,5

7,5

10

10

0,75

1,1

1,5

2,2

2,2

3

4

4

5,5

5,5

7,5

7,5

1 ~ 230 V3 ~ 230 ÷ 400 V

1 ~ 230 V3 ~ 230 ÷ 400 V

1 ~ 230 V3 ~ 230 ÷ 400 V

3 ~ 230 ÷ 400 V

3 ~ 230 ÷ 400 V3 ~ 400 ÷ 690 V

3 ~ 230 ÷ 400 V

3 ~ 230 ÷ 400 V

3 ~ 230 ÷ 400 V3 ~ 400 ÷ 690 V

3 ~ 230 ÷ 400 V3 ~ 400 ÷ 690 V

3 ~ 230 ÷ 400 V3 ~ 400 ÷ 690 V

3 ~ 230 ÷ 400 V3 ~ 400 ÷ 690 V

3 ~ 230 ÷ 400 V3 ~ 400 ÷ 690 V

53,5-2

7,94,5-2,6

10,56,1-3,5

8,5-4,9

14,3-8,3

8,5-4,9

11,6-6,7

25

31,5

36

21

31

41

52

62

82

103

124

144

165

185

206

19

29

38

48

58

77

96

115

134

154

173

192

16

24

32

40

48

64

80

96

112

128

144

160

14

21

27

34

41

55

69

82

96

110

123

137

11

16

22

27

33

44

55

65

76

87

98

109

E4630010 E4630020

E4630030 E4630040 E4630050 E4630060

E4630070

E4630080

E4630090

E4630100 E4630110

E4630120 E4630130

E4630140 E4630150

E4630160 E4630170

E4630180 E4630190

E4630200 E4630210

PUMP PERFORMANCE

CODEVLRX

MODEL

MotorPower

kWHPVOLTAGE Amp. µF

Dis

char

ge h

ead

in m

eter

s

CODEVLRI

QL/1'

m3/h

50 100 150 175 200

1210,5963

8,3-4,8

14,3-8,38,3-4,8

19,6-11,311,3-8,5

24,8-14,314,3-8,3

24,8-14,314,3-8,3

19,6-11,311,3-8,5

Page 42: Electric Pumps Catalogue

VLRI / X 16

42

NPS

H (m

)

0- Speed of rotation 2900 rpm- Performance in accordance with UNI EN ISO 9906 standard- Head and NPSH valid for water with p=1,0 Kg / dm3 at 20° C density- The power curve (Kw) refers to the shaft power each stage- % refers to the pump hydraulic performance

40

60

80

100

120

140

160

180

200

220

16-30/2

16-30

16-40

16-50

16-60

16-70

16-80

16-100

16-120

16-140

16-160

4

66,6

6

100

8

133,3

10

166,6

12

200

14

233,3

16

266,6

18

300

20

333,3

22

366,6

24

400

1234567

Q

Hm

L / 1'

m3/ h 2

33,3

20

40

Eff.

(%)

50

60

70

0,4

P2 (k

W)

0,5

0,6

0,7

0,8

0,9

1,0

kW

TABLE OF HYDRAULIC PERFORMANCE

VLRI / X 1650 Hz

2900 rpm

NPSH

Page 43: Electric Pumps Catalogue

43

VLR

I /

X

VLRI / X 16

TABLE OF SIZES AND WEIGHTS

215

245

Ø 20

28

Ø48

Ø10

3

Ø12

6

Ø16

5

Ø 13,5 n°4 holes

190

300

90

A

L

Ø D3

B

H

Ø D

VERSIONS AVAILABLE :

Type "F" : with 2" (DN50) round flanges. Counterflanges with 2" GAS thread on request.

Type "V" ( on request and only on VLRX ) : with 2" connections for Victaulic type joint. Couplings on request.

ModelDimensions (mm) Net Weight

(kg)

VLRI/X 16 - 30/2 FVLRI/X 16 - 30 FVLRI/X 16 - 40 FVLRI/X 16 - 50 FVLRI/X 16 - 60 FVLRI/X 16 - 70 FVLRI/X 16 - 80 FVLRI/X 16 - 100 FVLRI/X 16 - 120 FVLRI/X 16 - 140 FVLRI/X 16 - 160 F

A LB D H

460 464

509 575 620 665 710

830 92010101100

265315

335385385385385

495495495495

725 779

844 960100510501095

1325142515051595

185

200200260

260260

260260260

310310

130

140140185

185185

185185185

230230

44

48 51 74

76 82

84128132

173177

D3

140250

250300

300300300

350350

350350

E5730010

E5730020

E5730030 E5730040

E5730050 E5730060

E5730070 E5730080

E5730090 E5730100 E5730110 E5730120

E5730130 E5730140

E5730150 E5730160 E5730170 E5730180

E5730190 E5730200

VLRI/X 16 - 30/2F T

VLRI/X 16 - 30 F T

VLRI/X 16 - 40 F T

VLRI/X 16 - 50 F T

VLRI/X 16 - 60 F T

VLRI/X 16 - 70 F T

VLRI/X 16 - 80 F T

VLRI/X 16 - 100 F T

VLRI/X 16 - 120 F T

VLRI/X 16 - 140 F T

VLRI/X 16 - 160 F T

3

4

5,5

7,5

7,5

10

10

15

15

20

20

2,2

3

4

5,5

5,5

7,5

7,5

11

11

15

15

3 ~ 230 ÷ 400 V3 ~ 400 ÷ 690 V

3 ~ 230 ÷ 400 V3 ~ 400 ÷ 690 V

3 ~ 230 ÷ 400 V3 ~ 400 ÷ 690 V3 ~ 230 ÷ 400 V3 ~ 400 ÷ 690 V

3 ~ 230 ÷ 400 V3 ~ 400 ÷ 690 V

3 ~ 230 ÷ 400 V

3 ~ 230 ÷ 400 V

3 ~ 230 ÷ 400 V3 ~ 400 ÷ 690 V

3 ~ 230 ÷ 400 V3 ~ 400 ÷ 690 V

3 ~ 230 ÷ 400 V3 ~ 400 ÷ 690 V

3 ~ 230 ÷ 400 V3 ~ 400 ÷ 690 V

24,8-14,314,3-8,3

36,3-21,021,0-12,1

36,3-21,021,0-12,148,4-28,028,0-12,6

48,4-28,028,0-12,6

11,6-6,7

8,5-4,9

24,8-14,314,3-8,3

19,6-11,311,3-8,5

19,6-11,311,3-8,5

14,3-8,38,3-4,8

26

39

52

65

78

91

104

130

156

182

208

25

37

49

62

74

86

98

123

148

172

197

23

34

46

57

69

80

92

115

137

160

183

20

30

40

51

61

71

81

101

121

142

162

16

24

32

40

47

55

63

79

95

111

126

E5630010

E5630020

E5630030 E5630040

E5630050 E5630060

E5630070 E5630080

E5630090 E5630100 E5630110 E5630120

E5630130 E5630140

E5630150 E5630160 E5630170 E5630180

E5630190 E5630200

PUMP PERFORMANCE

CODEVLRX

MODEL

MotorPower

kWHPVOLTAGE Amp.

Dis

char

ge h

ead

in m

eter

s

CODEVLRI

QL/1'

m3/h

100 200 250 300 350

211815126

Page 44: Electric Pumps Catalogue

ACCESSORIES FOR VLR / VLRX / VLRI

44

VICTAULIC CONNECTIONS

CODE DESCRIPTION

ZA009020

ZA009030

Victaulic connection

MATERIALDIMENSIONS

CONNECTIONX Y Z

Cast iron

68

87

117

133

45

48

1” 1/442,2

2”60,3

ROUND FLANGES PN 16

CODE DESCRIPTION SPEC

Kit including 2 ovalflanges, boltsand gaskets

MATERIAL ext.D

HoleNo.

FThreaded To be

welded

Binter.S

D

B

SF

STEEL

140STAINLESSSTEEL

AISI 316

99,2 20 1”1/4 DN32ZA008460 N/A4

220 180 18 - DN100ZB901920 UNI EN1092-18

D3086KKK UNI EN1092-1140 4100 18 1”1/4 -

B7097KKK UNI EN1092-14150 110 18 1”1/2 -

B7098KKK UNI EN1092-14150 110 18 - DN40

B7050KKK UNI EN1092-14165 125 18 2” -

165 125 18 - DN50ZB901890 UNI EN1092-14

165 125 18 2”1/2 -B7051KKK N/A4

150 110 20 1”1/2 DN40ZB902120 N/A4

165 126 20 2” DN50ZB902130 N/A4

PN

16

16

16

16

16

16

16

16

16

16

B7698KKK

ZB902350

185 145 18 - DN65 UNI EN1092-18 25

235 190 22 - DN100 UNI EN1092-18 25

OVAL FLANGES

CODE DESCRIPTION

ZC001270

ZC001290

ZC001280

ZA008560

Kit including2 oval flanges,

bolts andgaskets

95

MATERIAL ext.D

inter.S

øholes

F Threaded

65

65

100

65

B

CAST IRON

ext.A68 11 1”

95CAST IRON 68 11 1”1/4

128CAST IRON 75 14 1”1/2

95STAINLESSSTEEL AISI 316

68 11 1”1/4Kit including 2 oval flanges, bolts and gaskets

D

B

SF

A

The accessory is included in the pump as a standard The accessory is optionalThese codes refer to the bare single flange, without bolts and gaskets*

SELECTION TABLE

TYPEVLR 2B VERSION A

ACCESSORY KIT N. 2 CIRCULAR FLANGES OVAL FLANGES

VLR 2B VERSION FVLR 4 VERSION AVLR 4 VERSION FVLR 8 VERSION AVLR 8 VERSION FVLR 16 VERSION FVLR 32 VERSION FVLR 66 VERSION F 66-50

VLRI/X 2B/4 VERSION AVLRI/X 2B/4 VERSION FVLRI/X 8 VERSION AVLRI/X 16 VERSION F

* * *CO

DE

D30

86K

KK

B70

97K

KK

B70

98K

KK

B70

50K

KK

B70

51K

KK

ZB

9018

90

B76

98K

KK

ZB

9019

20

ZA

0084

60

ZC

0012

70

ZC

0012

90

ZC

0012

80

ZA

0085

60

B Dimension 11/4” 11/2” DN 40 2” 21/2” DN 50 DN 65 DN 100 DN 32 1” 11/4” 11/2” 11/4”

Notes PN 16 PN 16 - PN 25 PN 25 PN 16 PN 16 CASTIRON

CASTIRON

CASTIRONPN 16 PN 16 AISI 316

ZB

9023

50

DN 100

PN 25

VLR 66 VERSION F 66-60

ZB

9021

20

DN 40

PN 16

ZB

9021

30

DN 50

PN 16

Page 45: Electric Pumps Catalogue

MULTINOX VEMULTISTAGE CENTRIFUGAL PUMPS

The Multinox-VE vertical multistage centrifugal pumps are especially suitablefor the manufacture of pumping assemblies, above all in cases where ahigh level of efficiency and silence is required with reduced overall floordimensions.

• HIGH HYDRAULIC EFFICIENCY• STRONG AND RESISTANT

Motor- Enclosed, externally ventilated- Level of protection IP 44.- Class F insulation.- Single phase power supply with capacitor. Permanently activated and thermal protection built into the motor winding.- Three phase power supply with external protection provided by the user.- Speed of rotation 2850 rpm.- Suitable for continuous use.

Applications- Pumping and distribution of water in domestic systems used on a continuous or intermittent basis- Booster systems- Washing systems, garden irrigation, fountains.- Firefighting systems

Usage limitations- Type of liquid: clean water with no suspended solids or abrasive material- Maximum liquid temperature 50°C- Maximum recommended suction height 6 m with foot valve- Maximum operating pressure: 9 bar 12bar (MULTINOX VE 200/110)

10

11

MULTINOX 200/110 T

46

1

67

9

8

5

4

3

2

8

Component

Outer liner (pump body)

Suction flange

Shaft (hydraulic end)

Mechanical seal

Counterface

O'ring

Material

X5 CrNi 1810 ( Aisi 304 ) Stainless steel

EN GJL 200 ( ex G20 ) Cast iron

X5 CrNi 1810 (Aisi 304) Stainless steel

Graphite

DESIGN FEATURES

Discharge flangeMotor bracket

Diffuser Technopolymer

12

3 Impeller Technopolymer with AISI 304 stainless steel shim ring

45

Ceramic

67

NBR 70 shore

EN GJL 200 ( ex G20 ) Cast iron

8

9

10 Adapter EN GJL 200 (ex G20) Grey cast ironon model 200/110

11 Motor joint EN GJS 400 (ex GS400) Nodular cast iron on model 200/110

Page 46: Electric Pumps Catalogue

47

MU

LTIN

OX

VE

TABLE OF HYDRAULIC PERFORMANCE

MULTINOX VE

TABLE OF SIZES AND WEIGHTS

ModelDimensions mm.

A

NetWeight

kg

PUMP PERFORMANCE

MODELCODE

AbsorbedPower

kWVOLTAGE Amp. µF. Q

L/1'

m3/h

20

HP 1,2

B DNM

140

8,4

180

10,8

60

3,6

100

6kW HP

C D E DNA

20

40

2,4

80

4,8

10

30

40

50

60

80

70

200

12

160

9,6

120

7,2

90

100

110

Q

Hm

L / 1'

m3/ h

MULTINOX-VE 200/40 M

MULTINOX-VE 200/40 T

1 ~ 220÷240 V

3 ~ 230÷400 V7

3,6-2,1

N4194010-B

N4194020-B1,5 1,1 20 33,7 32,1 27,6 21,5 13,12 1,5

MULTINOX-VE 200/52 M

MULTINOX-VE 200/52 T1,8 1,3

1 ~ 220÷240 V

3 ~ 230÷400 V8,5

5-2,925 44,9 42,8 36,8 28,6 17,5

N4194030-B

N4194040-B2,5 1,8

56,1 53,4 46 35,8 21,86-3,53 ~ 230÷400 V MULTINOX-VE 200/65 T N4194050-B

67,3 64,1 55,2 42,9 26,28-4,63 ~ 230÷400 V2,5 1,8 MULTINOX-VE 200/80 T N4194060-B 3,5 2,6

78,6 74,8 64,4 50,1 30,69-5,23 ~ 230÷400 V2,6 1,9 MULTINOX-VE 200/90 T N4194070-B 3,7 2,7

438 115 37 143 204 1" 1/4 1" 1/4 19 MULTINOX-VE 200/40

466 115 37 174 204 1" 1/4 1" 1/4 21 MULTINOX-VE 200/52

504 115 37 203 204 1" 1/4 1" 1/4 23 MULTINOX-VE 200/65

525 115 37 230 204 1" 1/4 1" 1/4 25 MULTINOX-VE 200/80

MULTINOX-VE 200/90 555 115 37 257 204 1" 1/4 1" 1/4 27

9,31 ~ 220÷240 V1,9 1,4

MULTINOX-VE 200/65 M N4194080-B2,7 2

35

101 96,2 82,8 64,4 39,310-5,63 ~ 230÷400 V3,5 2,6 MULTINOX-VE 200/110 T N4194090 4,4 3,2

MULTINOX-VE 200/110 760 115 37 320 204 1" 1/4 1" 1/4 36

200/110

200/90

200/80

200/65

200/52

200/40

NominalPower

Dis

char

ge h

ead

in m

eter

s

Page 47: Electric Pumps Catalogue

87

6

5

3

4

21

48

Single impeller centrifugal pumps manufactured from stainless steel AISI 304 with 2poles encased self-ventilated internally cooled asynchronous motor.Recommended for pumping clear water and liquids that are chemically non aggressivein domestic, agricultural and industrial sector.

• IMPELLER AND DIFFUSER IN AISI 304 STAINLESS STEEL• HIGH RELIABILITY• HIGH HYDRAULIC EFFICIENCY

SSCXCLOSE-COUPLED, SINGLE-IMPELLER CENTRIFUGALPUMP FEATURING AXIAL SUCTION AND RADIALDISCHARGE

Applications- Booster sets- Irrigation- Handling of non aggressive water and liquids- Gardening

Usage limitations- Type of liquid: chemically non aggressive clean water and liquids with no suspended solids- Max liquid temperature: 90°C- Max. operating pressure: 8 bar (PN8)

Motor- Enclosed, externally ventilated- IP55 protection level- Class F insulation- Single phase power supply with capacitor permanently activated and thermal protection built into the motor winding- Three phase power supply with external protection provided by the user- Rotation speed 2850rpm- Suitable for continuous use

Versions available- Standard: mechanical seal in graphite/ceramic and o-rings in NBR- Special: mechanical seal in silicon carbide and o-rings in Viton

Component

Pump body

Material

Stainless steel X5 CrNi 18-10 EN1.4301 (AISI 304)

DESIGN FEATURES

1Motor bracket Aluminum AISI 12 UNI 50762

Seal housing Stainless steel X5 CrNi 18-10 EN1.4301 (AISI 304)3Impeller Stainless steel X5 CrNi 18-10 EN1.4301 (AISI 304)4Motor shaft (hydraulic end) Stainless steel X5 CrNi 18-10 EN1.4301 (AISI 304)5

Rotating assemblymechanical seal

Graphite or silicon carbide6

Fixed assemblymechanical seal Ceramic or silicon carbide7

O-rings NBR 70Shore or Viton8

Page 48: Electric Pumps Catalogue

SSC

X

49

A D

DNMC

DN

AE

B

TABLE OF HYDRAULIC PERFORMANCE

SSCX

PUMP PERFORMANCE

MODELCODE

AbsorbedPower

kWVOLTAGE Amp. µF. Q

L/1'

m3/h

0

HP

Dis

char

ge h

ead

in m

eter

s

0

80

4,8

120

7,2

20

1,2

40

2,4kW HP

NominalPower 160

9,6

200

12

1 ~ 230 V3 ~ 230 ÷ 400 V

SSCX 200/16M SSCX 200/16T

N4600010 N4600020

1 14,5 14 12,5 9,50,75

1,2 17 16 15 131

20 19 17 151,15

SSCX 200/18M SSCX 200/18T

N4600030 N4600040

1 ~ 230 V3 ~ 230 ÷ 400 V

SSCX 210/22M SSCX 210/22T

N4600050 N4600060

16

18

21,5

6,5

10,5 6

11 6

3,53,1-1,8

43,1-1,8

4,93,8-2,2

12,5

16

1 ~ 230 V3 ~ 230 ÷ 400 V

25

24 23 21,5 191,35 SSCX 210/26M SSCX 210/26T

N4600070 N4600080

25,5 15,5 106,75-2,9

1 ~ 230 V3 ~ 230 ÷ 400 V

25

25,5 24,5 23 19,51,5 SSCX 210/28M SSCX 210/28T

N4600090 N4600100

27 16 107,35,6-3,2

1 ~ 230 V3 ~ 230 ÷ 400 V

25

1,1

1,4

0,55

0,75

0,85

1

1,1

0,8

1,05

1,5

1,9

2,1

1,4

2

0,75

0,9

1,1

1,4

1,55

1,05

1,5

4

TABLE OF SIZES AND WEIGHTS

ModelDimensions mm.

A

Weight

kgB DNMC D E DNA

SSCX 210/22

SSCX 200/18

SSCX 200/16 320

320

350

8,7

9,5

12,1

240

240

250

50,5

50,5

50,5

210

210

210

105

105

105

1" 1/4

1" 1/4

1" 1/4

1"

1"

1"

SSCX 210/26 350 13,6250 50,5 210 105 1" 1/4 1"

SSCX 210/28 350 13,8250 50,5 210 105 1" 1/4 1"

Q

Hm

L / 1'm3/ h

50

3

5

100

6

150

9

200

12

250

15

10

15

20

25

30

200/16

200/18

210/22

210/26

210/28

Special version part number NXXXXXXX-VQQ

Page 49: Electric Pumps Catalogue

50

DHRHORIZONTAL MULTISTAGE CENTRIFUGAL PUMPS

The DHR series pumps are horizontal, multistage, centrifugal and noself priming.All the rotating parts in contact with the pumped liquid are instainless steel.

Motor features– Asynchronous electric motor with enclosed stator and external ventilation– Single phase models with enclosed capacitor start/run and thermal protector in motor winding– Three phase motors with thermal protection to be installed by user– Class F insulation– Protection level IP54– Maximum ambient temperature 50 °C– Continuous duty

Applications– Pumping and distribution of water in domestic systems used on a continuous or intermittent basis– Booster systems– Washing systems, garden irrigation, fountains

• RELIABLE AISI 304 STAINLESS STEEL CONSTRUCTION• COMPACT, SMALL IN SIZE• DESIGNED FOR MINIMAL ELECTRICAL CONSUMPTION AND QUIET OPERATION

Component

Pump Casings

Motor Casing

Diffuser

Shaft

Seals / Gaskets

Mechanical seal

Material

GJL-200 (ASTM Class 35) cast iron

Diecast aluminum

X5CrNi18-10 (AISI 304) stainless steel

DESIGN FEATURES

Impeller

NBR

Ceramic / Graphite / NBR

X5CrNi18-10 (AISI 304) stainless steel

Pump Sleeve

X5CrNi18-10 (AISI 304) stainless steel

X5CrNi18-10 (AISI 304) stainless steel

1

2

34

5

67

8

1 5 6 3 4 7 8 1 2

Usage limitations– Type of liquid: clean water with no suspended solids or abrasive material– Maximum liquid temperature 90°C– Maximum recommended suction height: 6 m with foot valve (with max. liquid temp. at 50°C)– Maximum operating pressure: 10 bar (with 50°C liquid temperature) 6 bar (with 90°C liquid temperature)

Page 50: Electric Pumps Catalogue

51

DH

R 2

DHR 2

2-50

Ql / min

m3/ h

10

0,6

20

1,2

30

1,8

40

2,4

50

3

60

3,6

70

4,2

0

5

10

15

20

25

30

35

40

45

2-30

Hm

TABLE OF HYDRAULIC PERFORMANCE

DHR 250Hz

PUMP PERFORMANCE

MODELCODEkWHP

VOLTAGE Amp. µF. QL/1'

m3/hkWHP

Dis

char

ge h

ead

in m

eter

s

10

0,6

25

20

1,2

22,5

30

1,8

19

40

2,4

16

50

3

12

39 34,5 29,5 23 16,5

DHR 2-30 T 3 ~ 230/400 V0,67 0,500,40 0,30 1,9-1,1 -E9301003

DHR 2-50 M 1 ~ 230 V1,00 0,750,70 0,50 3,5 12,5E9302105

DHR 2-50 T 3 ~ 230/400 V1,00 0,750,70 0,50 2,5-1,8 -E9301005

DHR 2-30 M 1 ~ 230 V0,7 0,520,40 0,30 2,6 12,5E9302103

Absorbedpower P1

Nominalpower P2

Page 51: Electric Pumps Catalogue

DHR 4

52

Ql / min

m3/ h

20

1,2

40

2,4

60

3,6

80

4,8

100

6

120

7,2

140

8,4

0

5

10

15

20

25

30

35

40

45

50

55

4-60

4-50

4-40

4-30

4-20

Hm

TABLE OF HYDRAULIC PERFORMANCE

DHR 450Hz

PUMP PERFORMANCE

MODELCODEkWHP

VOLTAGE Amp. µF. QL/1'

m3/hkWHP

Dis

char

ge h

ead

in m

eter

s

40

2,4

50

3

60

3,6

80

4,8

100

6

120

7,2

17 16 15,5 13,5 11 7,5

23,5 22,5 21 18 14 10

32 30,3 29 25 20 14

39 38 35 31 25 17

49 47 45 40,6 34,2 25

DHR 4-20 M 1 ~ 230 V0,80 0,600,50 0,37 2,9 12,5E9402102

DHR 4-20 T 3 ~ 230/400 V0,78 0,580,50 0,37 2,1-1,2 -E9401002DHR 4-30 M 1 ~ 230 V1,10 0,800,70 0,50 3,7 12,5E9402103DHR 4-30 T 3 ~ 230/400 V1,05 0,780,70 0,50 2,6-1,5 -E9401003DHR 4-40 M 1 ~ 230 V1,34 1,000,95 0,70 4,5 16E9402104DHR 4-40 T 3 ~ 230/400 V1,34 1,000,95 0,70 3,3-2,0 -E9401004

DHR 4-50 M 1 ~ 230 V1,68 1,251,20 0,90 5,8 20E9402105DHR 4-50 T 3 ~ 230/400 V1,60 1,201,20 0,90 3,5-2,1 -E9401005

DHR 4-60 M 1 ~ 230 V2,15 1,601,50 1,10 7,7 31,5E9402106DHR 4-60 T 3 ~ 230/400 V2,00 1,501,50 1,10 5,9-3,4 -E9401006

Absorbedpower P1

Nominalpower P2

Page 52: Electric Pumps Catalogue

53

DH

R 2

/4

DHR 2/4

C

DD

NA

E

DNM

A F

B

DHR 2-50 M/T 362 11,5205/190 137,5 1”141 1”14271

DHR 4-20 M/T 339 10,5205/190 137,5 1”119 1” 1/414271

DHR 4-30 M/T 339 10,7205/190 137,5 1”119 1” 1/414271DHR 4-40 M/T 366 12205/190 137,5 1”146 1” 1/414271

DHR 4-50 M/T 394 13,9205/190 137,5 1”173 1” 1/414271

DHR 4-60 M/T 445 17230/209 149 1”200 1” 1/416080

DHR 2-30 M/T 326 10,2205/190 137,5 1”105 1”14271

TABLE OF SIZES AND WEIGHTS

Model Dimensions mm

A

Weight

C kgB DNMF DNAED

Page 53: Electric Pumps Catalogue

DHR 9

54

PUMP PERFORMANCE

MODELCODE

AbsorbedPower

kWVOLTAGE Amp. µF. Q

L/1'

m3/h

80

HP 4,8

200

12

260

15,6

120

7,2

160

9,6kW HP

NominalPower 240

14,4

40

2,4

33 27 19 5,137,5

43 35,5 26 648,5

3,35 2,5 49 40,1 28,8 6,12,55 1,9 3 ~ 230 ÷ 400 V 55,77,9 - 4,5

20

35

31,5

25

16,3 13,2 9,2 2,518,5

25,8 21,3 15,6 4,729,3

DHR9 - 60 TE9501006

2,68 22,15 1,6 3 ~ 230 ÷ 400 V 6,1 - 3,5DHR9 - 50 TE95010052,95 2,22,15 1,6 1 ~ 230 V 10DHR9 - 50 ME95021052,15 1,61,74 1,3 3 ~ 230 ÷ 400 V 5,3 - 3DHR9 - 40 TE95010042,41 1,81,74 1,3 1 ~ 230 V 8DHR9 - 40 ME95021041,81 1,351,27 0,95 3 ~ 230 ÷ 400 V 4,4 - 2,5DHR9 - 30 TE95010031,88 1,41,27 0,95 1 ~ 230 V 6DHR9 - 30 ME95021031,21 0,90,87 0,65 3 ~ 230 ÷ 400 V 3 - 1,7DHR9 - 20 TE95010021,34 10,87 0,65 1 ~ 230 V 4,5DHR9 - 20 ME9502102

10

14

14,4

4,5

9

40

50,6

60

20

31

0

5

10

15

20

25

30

35

40

45

50

55

60

65

P1

(kWass.) 3,00

2,50

2,00

1,50

1,00

0,50

3,00 6,00 9,00 12,00 15,00 18,000

50 100 150 200 250 3000

0,1

0,2

0,3

0,4

0,5

0,6

P(MPa)

Q (m3/h)Q (l/min.)

DHR950Hz

DHR9/60

DHR9/50

DHR9/40

DHR9/30

DHR9/20

DHR9/60

DHR9/50

DHR9/40

DHR9/30

DHR9/20

H(m)

TABLE OF HYDRAULIC PERFORMANCE

Dis

char

ge h

ead

in m

eter

s

Page 54: Electric Pumps Catalogue

55

DH

R 9

DHR 9

TABLE OF SIZES AND WEIGHTS

Model Dimensions mm. NetWeight

kg

DNMDNA

DHR 9 - 20 T

DHR 9 - 20 M

DHR 9 - 30 T

DHR 9 - 30 M

DHR 9 - 40 T

DHR 9 - 40 M

DHR 9 - 50 T

DHR 9 - 50 M

DHR 9 - 60 T

378

378

378

378

408

408

438

438

468

196

227

196

227

196

227

196

227

196

185

185

185

185

185

185

185

185

185

105

105

105

105

105

105

105

105

105

107

107

107

107

137

137

168

168

198

17,5

18,8

18,7

19

20

22

22,5

23,5

24,1

A B C D E

160

160

160

160

160

160

160

160

160

F

1”1/2

1”1/2

1”1/2

1”1/2

1”1/2

1”1/2

1”1/2

1”1/2

1”1/2

1”1/4

1”1/4

1”1/4

1”1/4

1”1/4

1”1/4

1”1/4

1”1/4

1”1/4

Page 55: Electric Pumps Catalogue

DHIMULTISTAGE CENTRIFUGALPUMPS IN AISI 316 STAINLESS STEEL

The DHI series horizontal multistage centrifugal pumps offer the following benefits:- High hydraulic pressure and flow rate performance- Minimum electrical energy consumption- Extremely silent operation

• HYDRAULIC IN AISI 316 STAINLESS STEEL

56

Motor- Enclosed, externally ventilated- Level of protection IP 54- Class F insulation- Single phase power supply with capacitor permanently activated and thermal protection built into the motor winding- Three phase power supply with external protection provided by the user- Speed of rotation 2850 rpm- Suitable for continuous use

Applications

- Aggressive liquids transfer- Pumping and distribution of water in domestic systems used on a continuous or intermittent basis- Booster systems- Washing systems, garden irrigation, fountains

Usage limitations- Types of pumped liquid: clear, non- explosive with no suspended solids or abrasive material- Maximum liquid temperature 90°C- Maximum recommended suction height 6 m with foot valve (with max. liquid temp. at 50°C)- Maximum operating pressure 6 bar

1 23 4 5 6 7 8

Component

Pump casing

Motor bracket

Motor shaft

Mechanical seal

Counterface

Seal holder plate

Material

AISI 316 Stainless steel

Die-cast aluminium

X CrNiMo 17-12-03 (AISI 316) Stainless steel

Graphite

DESIGN FEATURES

Intermediate chamber X CrNiMo 17-12-03 (AISI 316) Stainless steel

123 Impeller X CrNiMo 17-12-03 (AISI 316) Stainless steel

45

Ceramic

67

X CrNiMo 17-12-03 (AISI 316) Stainless steel8O'ring EPDM rubber

Page 56: Electric Pumps Catalogue

57

DH

I

DHI

PUMP PERFORMANCE

MODELCODE

AbsorbedPower

kWVOLTAGE Amp. µF. Q

L/1'

m3/h

10

HP 0,6

40

2,4

50

3

20

1,2

30

1,8kW HP

NominalPower 60

3,6

1 ~ 230 V3 ~ 230 ÷ 400 V

DHI 24 M DHI 24 T

N4221000 N4221070

32 28 25 20

4,32,0

46 40 34 270,75 DHI 26 M DHI 26 T

N4221010 N4221080

1 ~ 230 V3 ~ 230 ÷ 400 V

35

52

1 ~ 230 V3 ~ 230 ÷ 400 V

DHI 27 M DHI 27 T

N4221020 N4221090

57 50 43 350,9 63

3,41,4

5,32,4

16

20

32

0,550,75

1,00

1,25

0,751,00

0,951,30

1,201,65

16

19

26

TABLE OF HYDRAULIC PERFORMANCE

DHI 24 / 26 / 2750Hz

Dis

char

ge h

ead

in m

eter

s

Page 57: Electric Pumps Catalogue

DHI

58

TABLE OF HYDRAULIC PERFORMANCE

DHI 43 / 44 / 4550 Hz

22 18 16 120,75 0,55 DHI 43 M DHI 43 T

N4221030 N4221100

1 ~ 230 V3 ~ 230 ÷ 400 V

24

31 27 22 161,00 0,75 DHI 44 M DHI 44 T

N4221040 N4221110

1 ~ 230 V3 ~ 230 ÷ 400 V

33

36 33 27 181,25 0,9 DHI 45 M DHI 45 T

N4221050 N4221060

1 ~ 230 V3 ~ 230 ÷ 400 V

425,92,5

4,62,0

3,51,6

31,5

20

160,751,00

1,001,36

1,251,70

MODELCODE

AbsorbedPower

kWVOLTAGE Amp. µF. Q

L/1'

m3/h

40

HP 2,4

100

6

120

7,2

60

3,6

80

4,8kW HP

NominalPower

PUMP PERFORMANCE

Dis

char

ge h

ead

in m

eter

s

Page 58: Electric Pumps Catalogue

59

DH

I

DHI

TABLE OF SIZES AND WEIGHTS

Model Dimensions mm. NetWeight

kgDNMDNA

DHI 27

DHI 26

DHI 24

DHI 43

DHI 44

DHI 45

105

105

105

105

105

105

400

430

460

400

430

460

141

141

141

141

141

141

235

235

235

235

235

235

205

205

205

205

205

205

1”1/4

1”1/4

1”1/4

1”1/4

1”1/4

1”1/4

1”1/4

1”1/4

1”1/4

1”1/4

1”1/4

1”1/4

11,3

12,6

11,3

12,3

13,6

15,8

E1D1C1B1A1

Page 59: Electric Pumps Catalogue

- Supplied as standard N30 (on request N20)

APDEEP SUCTION SELF-PRIMING PUMPSCOMPLETE WITH EJECTOR

The JET AP 800, AP 1000 pumps are suitable for deep suction from wells with aminimum diameter of 4" using a recirculation system.

60

Motor- Enclosed, externally ventilated- Level of protection IP 44- Class F insulation- Single phase power supply with capacitor permanently activated and thermal protection built into the motor winding- Three phase power supply with external protection provided by the user- Speed of rotation 2850 rpm- Suitable for continuous use

Applications- Pumping and distribution- Booster systems

Usage limitations- Type of liquid: clean water with no suspended solids or abrasive material- Maximum liquid temperature 50°C- Maximum recommended suction height with foot valve: AP 800 = 30m AP 1000 = 35m - Maximum operating pressure 6 bar

Component

Pump casing

Motor bracket

Venturi tube and nozzle

Mechanical seal

Counterface

Material

Cast iron

Cast iron

Technopolymer

Graphite

DESIGN FEATURES

Impeller Technopolymer

12

3 Diffusors

45

Ceramic

67

8

Shaft Stainless steel

Technopolymer

Cast iron ejector

Page 60: Electric Pumps Catalogue

61

AP

AP

PUMP PERFORMANCE

MODELCODE

AbsorbedPower

kWVOLTAGE Amp. µF. Q

L/1'

m3/h

10

HP 0,6

25

1,5

30

1,8

15

0,9

20

1,2kW HP

Nominalpower 35

2,4

1,5 1,11,36 1AP 1000 MN4173030 5 16

1,3 1

22 11

1 0,75AP 800 MN4176630 1 ~ 220 ÷ 240 V

35

4,5 12,5

1 ~ 220 ÷ 240 V

1021

16 11 622

10 515

33 22 1149

19 1031

22 16 11 627

16 10 619

N20

N30

N20

N30

35

30

15

20

25

30

15

20

25

30

35 10 514

Dis

char

gehe

adin

met

ers

MaxSuction

EjectorType

Suction

m

TABLE OF SIZES AND WEIGHTS

ModelDimensions mm.

A

Weight

kgB DNMC D E DNA

15,8

340AP 800 13,2174 182 92 43 1 1/4" 1"

365AP 1000 174 182 92 43 1 1/4" 1"

Page 61: Electric Pumps Catalogue

MCXMULTISTAGE CENTRIFUGAL PUMPS

The MCX series horizontal multistage centrifugal pumps offer the following benefits:- High hydraulic pressure and flow rate performance- Minimum electrical energy consumption- Extremely silent operation

62

Motor- Enclosed, externally ventilated- Level of protection IP 44- Class F insulation- Single phase power supply with capacitor permanently activated and thermal protection built into the motor winding- Three phase power supply with external protection provided by the user- Speed of rotation 2850 rpm- Suitable for continuous use

Applications- Pumping and distribution of water in domestic systems- Booster systems- Firefighting systems- Washing systems, irrigation

Usage limitations- Type of liquid: clean water with no suspended solids or abrasive material- Maximum liquid temperature 50°C- Maximum recommended suction height 6 m with foot valve- Maximum operating pressure 7 bar

1 23 4 56 7

8910

Component

Pump casing

Motor bracket

Shaft (hydraulic end)

Mechanical seal

Counterface

O'ring

Material

X5 CrNi 1810 (AISI 304) Stainless steel

Die-cast aluminium

X5 CrNi 1810 (AISI 304) Stainless steel

Graphite

DESIGN FEATURES

Seal holder plate

Diffusors Technopolymer

12

3 Impeller Technopolymer with X5 CrNi 1810 (AISI 304) stainless steel shim ring

45

Ceramic

67

NBR 70 shore

GNF 2V Noryl (stainless steel on 200 Lt version)8

910 Spacer (on 200 Lt) X10 CrNiS 1809 (AISI 303) Stainless steel

Page 62: Electric Pumps Catalogue

63

MC

X

TABLE OF HYDRAULIC PERFORMANCE

MCX

TABLE OF SIZES AND WEIGHTS

ModelDimensions mm.

A

Weight

kg

PUMP PERFORMANCE

MODEL CODE

AbsorbedPower

kWVOLTAGE Amp. µF. Q

L/1

m3/

0

HP 0

B DNM

60

3,6

80

4,8

20

1,2

40

2,4kW HP

C D E DNA

NominalPower

Q

Hm

L / 1'm3/ h

20 1,2

20

10 0,6

30 1,8

40 2,4

50

3

60 3,6

70 4,2

80 4,8

10

30

40

50

60

1 ~ 230 V3 ~ 230 ÷ 400 V

MCX 80/36 M MCX 80/36 T

N4201180-B N4201240-B

0,8 0,6 28 21 13 0,50,6 0,45

1,1 0,8 36 28 17 10,75 0,55

1,3 1 50 40 27 31 0,75

MCX 80/48 M MCX 80/48 T

N4201190-B N4201250-B

1 ~ 230 V3 ~ 230 ÷ 400 V

MCX 80/60 M MCX 80/60 T

N4201200-B N4201260-B

1 ~ 230 V3 ~ 230 ÷ 400 V

35

45

57

2,92-1,2

42,6-1,5

4,82,9-1,7

12,5

12,5

16

MCX 80/60

MCX 80/48

MCX 80/36 90

90

90

6

7

8

296

318

360

99

99

99

190

190

195

174

174

174

1"

1"

1"

1"

1"

1"

Dis

char

ge h

ead

in m

eter

s

Page 63: Electric Pumps Catalogue

MCX

64

TABLE OF HYDRAULIC PERFORMANCE

TABLE OF SIZES AND WEIGHTS

ModelDimensions mm.

A

Weight

kg

PUMP PERFORMANCE

MODEL CODE

AbsorbedPower

kWVOLTAGE Amp. µF. Q

L/1

m3/

0

HP 0

B DNM

60

3,6

80

4,8

20

1,2

40

2,4kW HP

C D E DNA

NominalPower 100

6

Q

Hm

L / 1'm3/ h

20 1,2

20

40 2,4

60 3,6

80 4,8

10

30

40

50

60

120 7,2

100 6

1 ~ 230 V3 ~ 230 ÷ 400 V

1,1 0,8 33 28 22 140,75 0,55 4 MCX 120/36 M MCX 120/36 T

N4201210-B N4201270-B

1,5 1,1 42 37 27 181 0,75 51 ~ 230 V3 ~ 230 ÷ 400 V

1,7 1,25 55 48 36 261,2 0,9 10

MCX 120/48 M MCX 120/48 T

N4201220-B N4201280-B

MCX 120/60 M MCX 120/60 T

N4201230-B N4201290-B

1 ~ 230 V3 ~ 230 ÷ 400 V

36

48

60

3,52,9-1,7

4,63,6-2,1

5,83,5-2

12,5

16

20

90

90

90

MCX 120/36 8

MCX 120/48 9

MCX 120/60 10

316

338

360

99

99

99

195

195

195

174

174

174

1"

1"

1"

1"

1"

1"

Dis

char

ge h

ead

in m

eter

s

Page 64: Electric Pumps Catalogue

65

MC

X

TABLE OF HYDRAULIC PERFORMANCE

MCX

TABLE OF SIZES AND WEIGHTS

ModelDimensions mm.

A

Weight

kg

PUMP PERFORMANCE

MODEL CODE

AbsorbedPower

kWVOLTAGE Amp. µF. Q

L/1'

m3/h

20

HP 1,2

B DNM

140

8,4

180

10,8

60

3,6

100

6kW HP

C D E DNA

NominalPower

Q

Hm

L / 1'm3/ h

200 20

1,2

20

40

2,4

80

4,8 12

10

30

40

50

70

160

9,6

120

7,2

60

60 30 100 140 180

1,8 3,6 6,0 8,4 10,8

MCX 200/65

MCX 200/52

MCX 200/40 105

105

105

14

16

18

400

430

460

141

141

141

235

235

235

205

205

205

1" 1/4

1" 1/4

1" 1/4

1" 1/4

1" 1/4

1" 1/4

1 ~ 230 V3 ~ 230 ÷ 400 V

MCX 200/40 M MCX 200/40 T

N4201360-B N4201370-B

2 1,5 32,1 27,6 21,5 13,11,5 1,1

2,5 1,8 42,8 36,8 28,6 17,51,8 1,3

2,7 2,0 53,4 46 35,8 21,81,9 1,4

MCX 200/52 M MCX 200/52 T

N4201380-B N4201390-B

1 ~ 230 V3 ~ 230 ÷ 400 V

MCX 200/65 M MCX 200/65 T

N4201410-B N4201400-B

33,7

44,9

56,1

73,6-2,1

8,55-2,9

96-3,5

20

25

1 ~ 230 V3 ~ 230 ÷ 400 V

35

Dis

char

ge h

ead

in m

eter

s

Page 65: Electric Pumps Catalogue

• AISI 304 STAINLESS STEEL OUTER SHELL• CAST IRON MOTOR BRACKET AND SUCTION FLANGE• SUITABLE FOR CONTINUOUS USE• DESIGNED FOR MINIMAL ELECTRICAL CONSUMPTION AND QUIET OPERATION

The horizontal multistage centrifugal MULTINOX pumps are suitable for developing aconsiderable pressure and flow rate with extremely silent operation and with a minimumelectrical energy consumption.

MULTINOXMULTISTAGE CENTRIFUGAL PUMP

66

Motor– Enclosed, externally ventilated.– Level of protection IP 44.– Class F insulation.– Single phase power supply with capacitor permanently activated and thermal protection built into the motor winding.– Three phase power supply with external protection provided by the user.– Speed of rotation 2850 rpm.– Suitable for continuous use.

Applications– Pumping and distribution of water in domestic systems.– Booster systems.– Firefighting systems .– Washing systems.– Irrigation

Usage limitations– Type of liquid: clean water with no suspended solids or abrasive material.– Maximum liquid temperature 50 °C.– Maximum recommended suction height 6m with foot valve.– Maximum operating pressure 9 bar.

Component

Outer liner (pump body)

Suction flange

Diffuser

Material

X5 CrNi 1810 (AISI 304) Stainless steel

EN GJL 200 (ex G20) Cast iron

X5 CrNi 1810 (AISI 304) Stainless steel

DESIGN FEATURES

Impeller Technopolymer with stainless steel shim ring

12

3 Motor bracket4

5

6 Shaft (hydraulic end)

EN GJL 200 (ex G20) Cast iron

Technopolymer

7 Mechanical seal Graphite/Ceramic

12 3456 7

Page 66: Electric Pumps Catalogue

67

TABLE OF HYDRAULIC PERFORMANCE

PUMP PERFORMANCE

MODELCODE

Absorbedpower

kWVOLTAGE Amp. µF. Q

L/1'

m3/hHP

60

3,6

80

4,8

20

1,2

40

2,4kW HP

Nominalpower 100

6

0

0

MULTINOX

MU

LTIN

OX

N4184070-BN4184090-B

N4184080-BN4184100-B

N4184110-B

N4184120-B

N4185080-B

N4185100-B

N4185090-B

N4185110-B

MULTINOX 80/36MMULTINOX 80/36T

MULTINOX 80/48MMULTINOX 80/48T

MULTINOX 80/60M

MULTINOX 80/60T

MULTINOX 120/48M

MULTINOX 120/48T

MULTINOX 120/60M

MULTINOX 120/60T

0,60 0,45 3

2,3-1,3

1 ~ 230 V

3 ~ 230 ÷ 400 V

1 ~ 230 V

3 ~ 230 ÷ 400 V1 ~ 230 V

3 ~ 230 ÷ 400 V

1 ~ 230 V

3 ~ 230 ÷ 400 V

1 ~ 230 V

3 ~ 230 ÷ 400 V

0,9 0,65

0,60 0,45 0,9 0,65

0,75 0,55 1,1 0,8

0,75 0,55 1,1 0,81,00 0,75 1,5 1,1

1,00 0,75 1,5 1,1

1,00 0,75 1,3 1,1

1,00 0,75 1,5 1,1

1,20 0,9 1,7 1,25

1,20 0,9 1,7 1,25

3,8

2,7-1,6

5,5

3-1,8

4,7

3,3-1,95,9

3,5-2

12,5

12,5

20

16

20

4

4

7

9

15

20

25

15

20

30

29

36

22

29

42

37

46

28

37

51

43

53

33

43

57

48

58

TABLE OF SIZES AND WEIGHTS

ModelDimensions mm.

A

Weight

kgB DNMC D E DNA

MULTINOX 80/48 389 11,7176 171 126 138 1" 1"

MULTINOX 80/36 343 9,5158 148 126 130 1" 1"

MULTINOX 120/48 389 13,1175 171 126 138 1" 1"

MULTINOX 80/60 411 13,7175 193 126 138 1" 1"

MULTINOX 120/60 411 13,7175 193 126 138 1" 1"

20

10

30

40

50

60

70

0

120/48

120/60

80/60

80/4880/36

Q L / 1'm3/ h

20 1,2

10 0,6

30 1,8

40 2,4

50

3

60 3,6

70 4,2

80 4,8

905,2

1006,0

1107,2

Dis

char

ge h

ead

in m

eter

s

Page 67: Electric Pumps Catalogue

MAXSELF-PRIMING MULTISTAGE CENTRIFUGAL PUMPS

The MAX horizontal multistage centrifugal pumps combine the functional benefitsof centrifugal pumps and the practical benefits of self priming pumpsThey warrant high hydraulic and suction performances.

68

Motor- Enclosed, externally ventilated- Level of protection IP 44- Class F insulation- Single phase power supply with capacitor permanently activated and thermal protection built into the motor winding- Three phase power supply with external protection provided by the user- Speed of rotation 2850 rpm- Suitable for continuous use

Applications- Pumping and distribution of water in domestic systems- Booster systems- Firefighting systems- Washing systems, irrigation

Usage limitations- Type of liquid: clean water with no suspended solids or abrasive material- Maximum liquid temperature 50°C- Maximum recommended suction height 7m with foot valve- Maximum operating pressure 7 bar

1 234 56 7 8

9 10

Component

Pump casing

Motor bracket

Shaft (hydraulic end)

Mechanical seal

Counterface

O'ring

Material

X5 CrNi 1810 (AISI 304) Stainless steel

Die-cast aluminium

X5 CrNi 1810 (AISI 304) Stainless steel

Graphite

DESIGN FEATURES

Seal holder plate

Diffusors Technopolymer

12

3 Impeller Technopolymer with X5 CrNi 1810 (Aisi 304)Stainless steel shim ring

45

Ceramic

67

NBR 70 Shore

GFN2V Noryl

8

9

Spacer OT 58 Nickel plated brass

10

Wired version

Page 68: Electric Pumps Catalogue

69

MA

X

TABLE OF HYDRAULIC PERFORMANCE

MAX

TABLE OF SIZES AND WEIGHTS

ModelDimensions mm.

A

Weight

kg

PUMP PERFORMANCE

MODELCODE

AbsorbedPower

kWVOLTAGE Amp. µF. Q

L/1'

m3/h

0

HP 0

B DNM

60

3,6

80

4,8

20

1,2

40

2,4kW HP

C D E DNA

Nominalpower

Q

Hm

L / 1'm3/ h

20 1,2

20

10 0,6

30 1,8

40 2,4

50

3

60 3,6

70 4,2

80 4,8

10

30

40

50

60

50 40 27 3571,3 11 0,75 MAX 80/60 M MAX 80/60 T

N4501040-B N4501080-B

1 ~ 230 V3 ~ 230 ÷ 400 V

4,82,9-1,7

16

1,1 0,8 36 28 17 10,75 0,55 MAX 80/48 M MAX 80/48 T

N4501030-B N4501070-B

1 ~ 230 V3 ~ 230 ÷ 400 V

4542,6-1,5

12,5

MAX 80/60 129 9392 99 182 176 1" 1"

MAX 80/48 129 8370 99 182 176 1" 1"

Dischargehead

in meters

Page 69: Electric Pumps Catalogue

MAX

70

TABLE OF HYDRAULIC PERFORMANCE

PUMP PERFORMANCE

MODELCODE

AbsorbedPower

kWVOLTAGE Amp. µF. Q

L/1'

m3/h

0

HP

Dis

char

gehe

adin

met

ers

0

60

3,6

80

4,8

20

1,2

40

2,4kW HP

NominalPower 100

6

Q

Hm

L / 1'm3/ h

20

1,2

20

40

2,4

60

3,6

80

4,8

10

30

40

50

60

120

7,2

100

6

1,5 1,1 42 37 27 181 0,75 51 ~ 230 V3 ~ 230 ÷ 400 V

1,7 1,25 55 48 36 261,2 0,9 10

MAX 120/48 M MAX 120/48 T

N4501050-B N4501090-B

MAX 120/60 M MAX 120/60 T

N4501060-B N4501100-B

1 ~ 230 V3 ~ 230 ÷ 400 V

48

60

4,63,6-2,1

5,83,5-2

16

205,8

TABLE OF SIZES AND WEIGHTS

ModelDimensions mm.

A

Weight

kgB DNMC D E DNA

11

129 MAX 120/48 10393 99 192 176 1" 1"

129 MAX 120/60 392 99 182 176 1" 1"

N4501190-B MAX 120/60 C 1 ~ 230 V*

* Version equipped with cable, schuko plug, handle and switch

Page 70: Electric Pumps Catalogue

MULTINOX-ASELF-PRIMING MULTISTAGE CENTRIFUGAL PUMPS

The horizontal multistage centrifugal self-priming MULTINOX-A pumps are suitablefor developing a considerable pressure and flow rate with extremely silent operationand with minimum electrical energy consumption.

• STRONG AND RESISTANT• SELF PRIMING• HIGH SUCTION CAPABILITY• SPECIAL PATENTED BRASS VALVE FOR CLOSURE DURING THE PRIMING STAGE

71

Motor- Enclosed, externally ventilated- Level of protection IP 44- Class F insulation- Single phase power supply with capacitor permanently activated and thermal protection built into the motor winding- Three phase power supply with external protection provided by the user- Speed of rotation 2850 rpm- Suitable for continuous use

Applications- Pumping and distribution of water in domestic systems used on a continuous or intermittent basis- Booster systems- Washing systems, garden irrigation, fountains

Usage limitations- Type of liquid: clean water with no suspended solids or abrasive material- Maximum liquid temperature 50°C- Maximum recommended suction height 8 m with foot valve- Maximum operating pressure 9 bar

Component

Outer liner (pump body)

Suction flange

Shaft (hydraulic end)

Mechanical seal

Counterface

O'ring

Material

X5 CrNi 1810 (AISI 304) Stainless steel

EN GJL 200 (ex G20) Cast iron

X5 CrNi 1810 (AISI 304) Stainless steel

Graphite

DESIGN FEATURES

Discharge flangeMotor bracket

Diffusor Technopolymer

12

3 Impeller Technopolymer with AISI 304 stainless steel shim ring

45

Ceramic

67

NBR 70 shore

EN GJL 200 (ex G20) Cast iron

8

9

59761342

8

Page 71: Electric Pumps Catalogue

72

TABLE OF HYDRAULIC PERFORMANCE

MULTINOX-A

TABLE OF SIZES AND WEIGHTS

ModelDimensions mm.

A

Weight

kg

PUMP PERFORMANCE

B DNMC D E DNA

Q

441

469

200

200

188

215

155

155

170

170

1" 1/4

1" 1/4

1" 1/4

1" 1/4

19

21

MULTINOX 200/40

MULTINOX 200/52

497 200 243 155 170 1" 1/4 1" 1/4 23 MULTINOX 200/65

525 200 270 155 170 1" 1/4 1" 1/4 25 MULTINOX 200/80

200

Hm

L / 1'm3/ h

20

40 2,4

80 4,8

10

30

40

50

60

80

70

12 160 9,6

120 7,2

MODELECODEPuissance

Abs.

kWTENSION Amp. µF. Q

L/1'

m3/h

20

HP 1,2

140

8,4

180

10,8

60

3,6

100

6kW HP

MULTINOX-A 200/40 M MULTINOX-A 200/40 T

33,7 32,1 27,6 21,5 13,1 MULTINOX-A 200/52 M

MULTINOX-A 200/52 T MULTINOX-A 200/52 C*

44,9 42,8 36,8 28,6 17,5

MULTINOX-A 200/65 T56,1 53,4 46,0 35,8 21,8

MULTINOX-A 200/80 T 67,3 64,1 55,2 42,9 26,2

N418A010-B

N418A020-B

N418A050-B

N418A060-B

1,5 1,1 1 ~ 220÷240 V3 ~ 230÷400 V

63,6-2,1

20

1,8 1,31 ~ 220÷240 V3 ~ 230÷400 V1 ~ 220÷240 V

85-2,9

8

25

1,9 1,43 ~ 230÷400 V

2,5 1,8 3 ~ 230÷400 V 8-4,6

2 1,5

2,5 1,8

2,7 2

3,5 2,3

N418A030-B

N418A040-B N418A080-B

MULTINOX-A 200/65 M N418A070 1 ~ 220÷240 V 35

Hau

teur

mna

nom

étriq

ueen

m C

E

PuissanceNom.

9,36-3,5

*Supplied with switch, schuko plug and power supply cable

Page 72: Electric Pumps Catalogue

JETSELF-PRIMING CAST IRON PUMPS

The JET series self-priming pumps combine the functional benefits of centrifugalpumps and the practical benefits of self-priming pumps.The Venturi system the pumps are fitted with guarantees optimum hydraulicefficiency and considerable pressure capacity.

• STRONG AND RESISTANT• SELF-PRIMING• HIGH SUCTION CAPACITY

73

Motor- Enclosed, externally ventilated- Level of protection IP 44- Class F insulation- Single phase power supply with capacitor permanently activated and thermal protection built into the motor winding- Three phase power supply with external protection provided by the user- Speed of rotation 2850 rpm- Suitable for continuous use.

Applications- Pumping and distribution of water in domestic systems used on a continuous or intermittent basis- Booster systems- Washing systems, garden irrigation, fountains- Pumping from wells or tanks

Usage limitations- Type of liquid: clean water with no suspended solids or abrasive material- Maximum liquid temperature 50°C- Maximum recommended suction height 8m with foot valve- Maximum operating pressure: 6 bar (10 bar model 100-160)

Component

Pump casing

Motor bracket

Diffusor venturitube and nozzle

Mechanical seal

Counterface

O-ring

Material

EN GJL (ex G20) Cast iron

Aluminium

Graphite

DESIGN FEATURES

Impeller

Ceramic

NBR 70 shore

Technopolymer withX5 CrNi 1810 (AISI 304)Stainless steel shim ring

JETNEW JETEN GJL (ex G20) Cast iron

EN GJL (ex G20) Cast iron

Technopolymermodels 600-800-1000Pressed brass alloymodels 100-160-800-1000

Monobloc assembly:Technopolymer Technopolymer

Motor shaft X12 CrNiS 1809 (AISI 416)Stainless steel

X12 CrNiS 1809 (AISI 416)Stainless steel

Graphite

Ceramic

NBR 70 shore

Page 73: Electric Pumps Catalogue

74

TABLE OF HYDRAULIC PERFORMANCE

JET

60/50

45/43

TABLE OF SIZES AND WEIGHTS

180 174 NEWJET 40/40 351 93 130 1" 1" 8,2

351

ModelDimensions mm.

A

Weight

B C DNA DNM kgD E

180 174 NEWJET 60/50 93 130 1" 1" 9

PUMP PERFORMANCE

MODELCODE

AbsorbedPower

kWHPVOLTAGE Amp. µF. Q

L/1'

m3/h

0 10 20 30 40 50 60NominalPower

kWHP 0,6 1,2 1,8 2,4 3 3,6

70

4,2

1 ~ 220 ÷ 240 V NEWJET 45/43 M N4176050 430,8 0,6 30 23 16 10,5 0,37

1 ~ 220 ÷ 240 V NEWJET 60/50 M N4176580 461,1 0,8 36 31 26 18 60,75 0,55

3

4

8

12,5

20

1,2

Hm

L / 1'm3/ h

Q

20

10

0,6

30

1,8

40

2,4

50

3

60

3,6

70

4,2

80

4,8

10

30

40

50

1 ~ 220 ÷ 240 V NEWJET 40/40 M N4176800 410,8 0,6 28 21 80,5 0,37 3 6

40/40

180 174 NEWJET 45/43 351 93 130 1" 1" 8,2

Dis

char

ge h

ead

in m

eter

s

Page 74: Electric Pumps Catalogue

JET

TABLE OF HYDRAULIC PERFORMANCE

75

PUMP PERFORMANCE

MODELCODE

AbsorbedPower

kWHPVOLTAGE Amp. µF. Q

L/1'

m3/h

0 5 20 30 40 50 60NominalPower

kWHP 0 0,3 1,2 1,8 2,4 3 3,6

70

4,2

TABLE OF SIZES AND WEIGHTS

ModelDimensions mm.

A

Weight

B C DNA DNM kgD E

JET 1000

JET 800

JET 600 400

400

425

147

147

147

160

160

160

1"

1"

1"

1"

1"

1"

13,7

14,2

16,8

190

190

190

182

182

182

20

1,2

Hm

L / 1'm3/ h

Q

20

10

0,6

30

1,8

40

2,4

50

3

60

3,6

70

4,2

80

4,8

10

30

40

50

JET 1000 M JET 1000 T

1 ~ 220 ÷ 240 V3 ~ 230 ÷ 400 V

JET 600 M JET 600 T

N4171010 N4171020

420,9 0,7 38 25 20 110,8 0,6

481,3 1 44 36 31 271 0,75

491,5 1,1 45 36 32 281,36 1

7

25 15 3

N4176550 N4176560

N4173010 N4173020

JET 800 M JET 800 T

1 ~ 220 ÷ 240 V3 ~ 230 ÷ 400 V

1 ~ 220 ÷ 240 V3 ~ 230 ÷ 400 V

3,21,9-1,1

4,53,6-2,1

53,8-2,2

8

12,5

16

JE

T JET 1000 M O * JET 1000 T O *

491,5 1,1 45 36 32 281,1 0,8 25 15 3 N4176810 N4176820

1 ~ 220 ÷ 240 V3 ~ 230 ÷ 400 V

53,8-2,2

16

481,3 1 44 36 31 271 0,75 7 N4176860 N4176830

JET 800 M O * JET 800 T O *

1 ~ 220 ÷ 240 V3 ~ 230 ÷ 400 V

4,53,6-2,1

12,5

* Version with brass impeller

Dis

char

ge h

ead

in m

eter

s

Page 75: Electric Pumps Catalogue

76

TABLE OF HYDRAULIC PERFORMANCE

JET

TABLE OF SIZES AND WEIGHTS

PUMP PERFORMANCE

1 ~ 230 V3 ~ 230 ÷ 400 V

JET 100/50 M JET 100/50 T

N4175010 N4175020

MODELCODE

AbsorbedPower

kWHPVOLTAGE Amp. µF. Q

L/1'

m3/h

5 40 60 80 100

2,2 1,6 50 40 35 31

130NominalPower

kWHP

1,5 1,1

2,7 2 60 49 42,5 36,52 1,5

3,4 2,5 70 58 51,5 46,53 2,2 3 ~ 230 ÷ 400 V

160

30,5

42

JET 100/68 M JET 100/68 T

N4175030 N4175040

JET 100/80 T N4175050

2,7 2 52 48 45 422 1,5 38,7 33,2 27 JET 160/52 M JET 160/52 T

N4175080 N4175090

3,4 2,5 59 53 47 43,43 2,2 40 36 32,5 JET 160/60 T N4175100

1 ~ 230 V3 ~ 230 ÷ 400 V

1 ~ 230 V3 ~ 230 ÷ 400 V

3 ~ 230 ÷ 400 V

27

0,3 2,4 3,6 4,8 6 7,8 9,6

8,15,3-3

7,9-4,7

9,86,3-3,6

10,56,8-3,9

7,9-4,6

35

40

40

20

45

55,5

64,3

49,5

55,6

1,2

JET 100/80 - 160/60

JET 100/68 - 160/52

JET 100/50

ModelDimensions mm.

A

Weight

kg

180

180

180

27

29

31

B

157

157

157

C

500

500

500

D

220

220

220

E

180

180

180

F

235

235

235

H1

170

170

170

227

227

227

DNA

1" 1/2

1" 1/2

1" 1/2

DNM

1"

1"

1"

H2

Dis

char

ge h

ead

in m

eter

s 20

2,4

Hm

L / 1'm3/ h

Q

20

1,2 3,6

40

4,8

100

6

60

7,2 8,4 9,6

10

30

40

50

60

80

70

80 120 160 140

Page 76: Electric Pumps Catalogue

JETINOXSELF-PRIMING STAINLESS STEEL PUMPS

The JETINOX series self-priming pumps combine the functional benefits of centrifugalpumps and the practical and qualitative benefits of self-priming pumps.The Venturi system the pumps are fitted with guarantees optimum hydraulic efficiencyand considerable pressure capacity.

• SELF-PRIMING• HIGH SUCTION CAPACITY

77

Motor- Enclosed, externally ventilated- Level of protection IP 44- Class F insulation- Single phase power supply with capacitor permanently activated- Thermal protection built into the motor winding- Speed of rotation 2850 rpm- Suitable for continuous use

Applications- Pumping and distribution of water in domestic systems used on a continuous or intermittent basis- Booster systems- Washing systems, garden irrigation, fountains- Pumping from wells or tanks

Usage limitations- Type of liquid: clean water with no suspended solids or abrasive material- Maximum liquid temperature 50°C- Maximum recommended suction height 8m with foot valve- Maximum operating pressure 6 bar

1

2

3

4

5

6

7

8

9

Component

Pump casing

Motor bracket

ImpellerMonobloc diffusor Venturitube nozzle assembly

Shaft

Mechanical seal

Counterface

Seal holder plate

O-ring

Material

X5 CrNi 1810 (AISI 304) Stainless steel

Die-cast aluminium

Technopolymer with stainless steel shim ring

Technopolymer

X12 CrNiS 1809 (AISI 416) Stainless steel

Graphite

CeramicTechnopolymer (models 45-60-70)X5 CrNi 1810 (AISI 304) Stainless steel (model 90)NBR 70 Shore

DESIGN FEATURES

Wired version

1

234

5

6 7

89

9

Page 77: Electric Pumps Catalogue

78

TABLE OF HYDRAULIC PERFORMANCE

JETINOX

PUMP PERFORMANCE

20

1,2

40

2,4

60

3,6

80

4,8

120

7,2

100

6

Hm

L / 1'm3/ h

Q

20

10

30

40

50

60

45 /43

60 /50 70 /50 90 /43

TABLE OF SIZES AND WEIGHTS

ModelDimensions mm.

A

Weight

B C DNA DNM kgD E

1" F JETINOX 45/43

374 JETINOX 60/50 93 140 190 178 8,2

351 93 140 190 178

1" F

4,7

1" F

1" F

1" F

1" F

397 JETINOX 90/43 98 168 220 235 111" 1/4 M 1" F

JETINOX 70/50 351 76 144 196 180 9,5

430 JETINOX 90/50 98 168 260 235 131" 1/4 M 1" F

90 /50

* Supplied with handle, switch, schuko plug and power supply cable

1 ~ 220÷240 V

1 ~ 220÷240 V 3 8 43 30 23 16 1

1 ~ 220÷240 V JETINOX 70/50 M

JETINOX 45/43 M 0,5 0,37 N4176190 0,8 0,6

MODELCODE

Absorbedpower

kWHPVOLTAGE

( V )Amp. µF. Q

L/1'

m3/h

0 10 20 30 40 50 60Nominalpower

kWHP 0,6 1,2 1,8 2,4 3 3,6

70

4,2

80

4,8

JETINOX 90/43 M 1,0 0,75 6,5 20 38 34 32 29 27 25 N4176280 1,8 1,3 43 1021

0,95 0,7 1,01,36 16 42,5 37,5 32 25 16,5 7

1 ~ 220÷240 V 4 12,5 36 31 26 18 646 JETINOX 60/50 M 0,75 0,55 N4176570 1,1 0,8

N41767604,5 48

1 ~ 220÷240 V JETINOX 90/50 M 1,2 0,9 7 25 42 39 37 33 30 27 N4176500 2 1,5 50 2025

1 ~ 230 V JETINOX 60/50 C N4176910

1 ~ 230 V JETINOX 70/50 C N4176900

1 ~ 230 V JETINOX 90/43 C N4176890

*

*

* Dis

char

ge h

ead

in m

eter

s

Page 78: Electric Pumps Catalogue

NRM CLOSE-COUPLED CENTRIFUGAL PUMPS (2 - 4 Poles)

79

Page 79: Electric Pumps Catalogue

NRM CLOSE-COUPLED CENTRIFUGAL PUMPS (2 - 4 Poles)

The NRM series is made up of single stage electric monobloc pumps with a flangedhydraulics/motor connection.The pump casing is manufactured in accordance with the provisions of EN733/DIN24255.The pumps may be installed in all positions, except where the suction port is directedupwards

• STRONG AND RESISTANT• WIDE RANGE• HIGH HYDRAULIC PERFORMANCE

80

Motor- Type: induction, enclosed, ventilated- Level of protection : IP 55- Insulation class F- Design: B3/B5- Speed of rotation: NRM4 1450 rpm NRM2 2900 rpm

Applications- Air conditioning and heating systems- Pumping of water from lakes, watercourses, wells- Overhead or surface irrigation- Water supply systems.- Boosting and firefighting systems.

Usage limitations- Type of liquid: non-aggressive, non-explosive, free from solid particles and fibres.- Hot water for heating- Coolants- Environmental temp.: max 40°C- Temperature of pumped liquid: -10°C + 130°C- Maximum operating pressure: 10 bar

2

1

345

Pump casing

Motor bracketImpellerShaftMechanical seal

EN GJL 200 ( ex G20 ) Cast iron

AISI 420 stainless steelSilicum carbide/Silicum carbide

EN GJL 200 ( ex G20 ) Cast ironEN GJL 200 ( ex G20 ) Cast iron

Component Material

DESIGN FEATURES

Page 80: Electric Pumps Catalogue

NRM2

81

Performance range

Q:(L/min)

400

100 200 400 1000 2000 4000

5

6

8

10

20

30

40

50

60

80

100

150

50x32x250

50x32x200

50x32x160

50x32x125

80x65x250

80x65x200

80x65x160

80x65x125

65x40x250

65x40x200

65x40x160

65x40x125

65x50x250

65x50x200

65x50x160

65x50x125

100x80x160

100x80x125

100x80x200

125x100x200

H(m)

NR

M

2 POLES

Page 81: Electric Pumps Catalogue

82

NRM2 50X32

PUMP PERFORMANCE

MODELCODE

NominalPower

kWHP

Amp.3 X 400 V

QL/1'

m3/h

200 225 250 275 300 350 400175VOLTAGE( V )

NRM2 50X32X125CAT07003 11,5 10,3 21,5 7,512,5 614,5 13,515,5

17 16 15 13,518 11,5 7,520 1920,5

22 21 20 18,523 16,5 1324 23,524,5

25,5 24 23 2126,5 20 1528 27,528,5

31 30 29 27,532 26 22,533 32,533,5

35 34 33 31,536 30 26,537,5 3738

44 43 42 4145 39,5 37,5 3546,5 4647

53 52 51 49,553,5 48 45 4254,5 5455

59 58 57 5660 54 52,5 4961,5 6162

64 63 61,5 6065 58 5466,5 6667

80 79 78 76,580,5 75 71 6681,5 8182

91 90,5 90 8991,5 88 85 8092,5 9293

125 150100

AT07005

AT07007

AT07011

AT07013

AT07015

AT07019

AT07020

AT07021

AT07022

AT07023

AT07024

AT07027

AT07028

AT07029

AT07030

AT07032

NRM2 50X32X125B

NRM2 50X32X125A

NRM2 50X32X160C NRM2 50X32X160B

NRM2 50X32X160A

NRM2 50X32X200C

NRM2 50X32X200C

NRM2 50X32X200B NRM2 50X32X200B

NRM2 50X32X200A

NRM2 50X32X200A

NRM2 50X32X250C

NRM2 50X32X250C

NRM2 50X32X250B NRM2 50X32X250B

NRM2 50X32X250A

1 0,75

1,35 1

2 1,5

2,7 2

4 3

4 3

5,5 4

7,5 5,5

8,5 6,3

10 7,5

13,5 10

17 12,5

TABLE OF SIZES AND WEIGHTS

ModelDimension mm. Weight

NRM2 50X32X125C

Motor DNm DNa

PN16 PN16

NRM2 50X32X125B

NRM2 50X32X125A

NRM2 50X32X160C

NRM2 50X32X160B

NRM2 50X32X160A

NRM2 50X32X200C

NRM2 50X32X200B

NRM2 50X32X200A

NRM2 50X32X250C

NRM2 50X32X250B

NRM2 50X32X250A

fig.

1

1

1

1

1

1

1

1

1

1

1

1

a h1

112

112

112

132

132

132

160

160

160

180

180

180

h2

140

140

140

160

160

160

180

180

180

225

225

225

b

50

50

50

50

50

50

50

50

50

65

65

65

m1

100

100

100

100

100

100

100

100

100

125

125

125

m2

70

70

70

70

70

70

70

70

70

95

95

95

n1

190

190

190

240

240

240

240

240

240

320

320

320

n2

140

140

140

190

190

190

190

190

190

250

250

250

s

14

14

14

14

14

14

14

14

14

14

14

14

C

12

12

12

12

12

12

12

12

12

12

12

12

W L

400

425

425

425

465

465

505

515

515

535

640

640

Z B

220

220

220

270

270

270

280

280

280

345

345

345

H

252

252

252

292

292

292

340

340

340

405

405

405

E

118

118

118

149

149

149

159

159

159

184

184

184

21

22

23,5

28

33

35

53,5

53

53

66

80

87

80

80

80

80

80

80

80

80

80

100

100

100

50

50

50

50

50

50

50

50

50

50

50

50

32

32

32

32

32

32

32

32

32

32

32

32

71

80

80

80

90

90

100

112

112

112

132

132

220/380

220/380

220/380

220/380

220/380

220/380

220/380

220/380

220/380

220/380

220/380

380/415

380/415

380/415

380/415

380/415

380/415

3,3/1,9

4,2/2,4

6,2/3,6

7,7/4,4

11/6,4

11/6,4

15,2/8,8

19,5/11,3

23,3/13,5

30/17,3

39/22,5

27

22,5

17,3

13,5

11,3

8

n° d1 holes ø e1

DN a 1 b 1 c 1

UNI PN 16 DN a1 b1 c1 d1 e1

32 78 100 140 4 1850 102 125 165 4 18

Flange

12 13,5 15 16,5 18 21 2410,57,5 96

Dis

char

ge h

ead

in m

eter

s

Page 82: Electric Pumps Catalogue

NRM2 65X40

83

PUMP PERFORMANCE

MODELCODE

NominalPower

kWHP

Amp.3 X 400 V

QL/1'

m3/h

400 450 500 550 600 650 700350VOLTAGE( V )

NRM2 65X40X125CAT07035 13 11,8 10,5 914,1 715,3 1515,5

16,5 15,5 14,5 1317,5 10,518,8 18,519

23 22 20,5 1923,5 1724,3 2424,5

26,5 25 23 20,528 1829,5 2930

33,5 32,5 31 2934,5 2736 35,536,5

41,5 39 37 3443 3145 4446

47,5 45 42,5 4049 3750,5 5051

53 51 49 4754,5 4456 55,556,5

65 63 61 5966,5 57 5468,5 6869

73 71 69 6774,5 65 62,576,5 7677

87 85 83 80,588 78 75 7189,5 8990

275 300250

AT07037

AT07039

AT07043

AT07045

AT07046

AT07049

AT07050

AT07051

AT07052

AT07053

AT07054

AT07057

AT07058

AT07060

AT07062

NRM2 65X40X125B

NRM2 65X40X125A

NRM2 65X40X160B NRM2 65X40X160A

NRM2 65X40X160A

NRM2 65X40X200C

NRM2 65X40X200C

NRM2 65X40X200B NRM2 65X40X200B

NRM2 65X40X200A

NRM2 65X40X200A

NRM2 65X40X250D

NRM2 65X40X250D

NRM2 65X40X250C NRM2 65X40X250B

2 1,5

2,7 2

4 3

4 3

5,5 4

7,5 5,5

8,5 6,3

10 7,5

13,5 10

17 12,5

20 15

TABLE OF SIZES AND WEIGHTS

ModelDimensions mm. Weight

NRM2 65X40X125C

Motor DNm DNa

PN16 PN16

NRM2 65X40X125B

NRM2 65X40X125A

NRM2 65X40X160B

NRM2 65X40X160A

NRM2 65X40X200C

NRM2 65X40X200B

NRM2 65X40X200A

NRM2 65X40X250D

NRM2 65X40X250C

NRM2 65X40X250B

fig.

1

1

1

1

1

1

1

1

1

1

1

a h1

112

112

112

132

132

160

160

160

180

180

180

h2

140

140

140

160

160

180

180

180

225

225

225

b

50

50

50

50

50

50

50

50

65

65

65

m1

100

100

100

100

100

100

100

100

125

125

125

m2

70

70

70

70

70

70

70

70

95

95

95

n1

240

210

210

240

240

265

265

265

320

320

320

n2

190

160

160

190

190

212

212

212

250

250

250

s

14

14

14

14

14

14

14

14

14

14

14

C

12

12

12

12

12

12

12

12

12

12

12

W L

425

425

465

465

505

535

535

535

640

640

640

Z B

425

425

255

280

280

300

300

300

280

280

345

H

252

252

252

292

292

340

340

340

405

405

405

E

149

149

149

159

159

159

159

159

184

184

184

24,5

25,5

30

30

40

54

54,5

54,5

77

85

92

80

80

80

80

80

100

100

100

100

100

100

65

65

65

65

65

65

65

65

65

65

65

40

40

40

40

40

40

40

40

40

40

40

80

80

90

90

100

112

112

132

132

132

132

60

NR

M

220/380

220/380

220/380

220/380

220/380

380/415

220/380

380/415

220/380

380/415

220/380

380/415

220/380

380/415

380/415

380/415

6,2/3,6

7,7/4,4

11/6,4

11/6,4

15,2/8,8

8,8

19,5/11,3

11,3

23,3/13,5

13,5

30/17,3

17,3

39/22,5

22,5

27

32

UNI PN 16 DN a1 b1 c1 d1 e1

40 88 110 150 4 1865 122 145 185 4 18

Flange

n° d1 holes ø e1

DN a 1 b 1 c 1

24 27 30 33 36 39 422116,5 1815

Dis

char

ge h

ead

in m

eter

s

Page 83: Electric Pumps Catalogue

84

NRM2 65X50

TABLE OF SIZES AND WEIGHTS

PUMP PERFORMANCE

fig.2

n° d1 holes ø e1

DN a 1 b 1 c 1

UNI PN 16 DN a1 b1 c1 d1 e1

50 102 125 165 4 1865 122 145 185 4 18

Flange

fig.1

ModelDimensions mm. Weight

NRM2 65X50X125C

Motor DNm DNa

PN16 PN16

NRM2 65X50X125B

NRM2 65X50X125A

NRM2 65X50X160B

NRM2 65X50X160A

NRM2 65X50X200A

NRM2 65X50X200B

NRM2 65X50X250D

NRM2 65X50X250C

NRM2 65X50X250B

fig.

1

1

1

1

1

1

1

1

2

2

a h1

132

132

132

160

160

160

160

180

180

180

h2

160

160

160

180

180

200

200

225

225

225

b

50

50

50

50

50

50

50

65

55

55

m1

100

100

100

100

100

100

100

125

298

298

m2

70

70

70

70

70

70

70

95

241

241

n1

240

240

240

265

265

265

265

320

320

320

n2

190

190

190

212

212

212

212

250

280

280

s

14

14

14

14

14

14

14

14

14

14

C

12

12

12

12

12

12

12

14

22

22

W L

445

485

525

535

535

640

640

640

800

800

Z B

245

270

280

300

300

320

320

345

390

390

H

292

292

292

340

340

360

360

405

405

405

E

118

149

159

159

159

184

184

184

230

230

29,5

36,5

41

51,5

52

68

75

93

128

146

100

100

100

100

100

100

100

100

100

100

65

65

65

65

65

65

65

65

65

65

50

50

50

50

50

50

50

50

50

50

80

90

100

112

112

132

132

132

160

180

280

280

20

20

MODELCODE

NominalPower

kWHP

Amp.3 X 400 V

QL/1'

m3/h

600 650 700 750 800 900 1000550VOLTAGE( V )

NRM2 65X50X125CAT07065 15 14 13 1215,5 1116,5 1617

19 18,3 17,5 16,819,5 16 1420,5 2021

24 23,5 23 22,524,5 21,5 2025,3 2525,5

30,5 30 29,5 2931 28 2632 31,532,5

35 34,5 34 33,535,5 32,5 31 2936,5 3637

48 47 45,5 4449 42 39,5 3750,5 5051

68 67 66 64,569 63 60 5671 7072

90 89 88 8791 86 8391,8 91,592

450 500400

AT07067

AT07069

AT07070

AT07073

AT07074

AT07075

AT07076

AT07079

AT07080

AT07082

AT07086

AT07088

AT07090

NRM2 65X50X125B

NRM2 65X50X125A

NRM2 65X50X125A NRM2 65X50X160B

NRM2 65X50X160B

NRM2 65X50X160A

NRM2 65X50X160A

NRM2 65X50X200B NRM2 65X50X200B

NRM2 65X50X200A

NRM2 65X50X250D

NRM2 65X50X250C

NRM2 65X50X250B

2,7 2

4 3

5,5 4

7,5 5,5

10 7,5

13,5 10

25 18,5

30 22

Dis

char

ge h

ead

in m

eter

s

20 15

17 12,5 55 54 53 51,556 50 46,5 42,557,5 5758

77,5 76,5 75,5 74,578,5 73,5 71 67,580 79,580,5

80

12

18

23,5

9220/380

220/380

220/380

380/415

220/380

380/415

220/380

380/415

220/380

380/415

380/415

380/415

380/415

380/415

7,7/4,4

11/6,4

15,2/8,8

8,8

19,5/11,3

11,3

30/17,3

17,3

39/22,5

22,5

27

32

38

45

36 39 42 45 48 54 603327 3024

Page 84: Electric Pumps Catalogue

PUMP PERFORMANCE

NRM2 80X65

85

MODELCODE

NominalPower

kWHP

Amp.3 X 400 V

QL/1'

m3/h

800 900 1000 1250 1500 2000 2250750VOLTAGE( V )

NRM2 80x65X125CAT0709316 15,5 14,5 1216,5 917,3 1717,5

20 19,5 19 1720,3 14,520,8 20,621

24 23,5 23 21,524,3 1924,8 24,625

30 29,5 29 26,530,3 2430,5

40,5 40 39,5 3840,8 35,541

44 43,5 41,5 39 35,5

64 63,5 63 61 57

77 76 74 70

86 85 83 79

650 700600

AT07094

AT07095

AT07096

AT07097

AT07098

AT07103

AT07104

AT07106

AT07108

AT07112

AT07114

AT07116

AT07120

AT07122

AT07124

NRM2 80x65X125C

NRM2 80x65X125B

NRM2 80x65X125B NRM2 80x65X125A

NRM2 80x65X125A

NRM2 80x65X160C

NRM2 80x65X160C

NRM2 80x65X160B NRM2 80x65X160A

NRM2 80x65X200D

NRM2 80x65X200C

NRM2 80x65X200B

NRM2 80x65X250D

NRM2 80x65X250C NRM2 80x65X250B

5,5 4

7,5 5,5

8,5 6,3

13,5 10

25 18,5

30 22

30 22

40 30

50 37

TABLE OF SIZES AND WEIGHTS

ModelDimensions mm. Weight

NRM2 80X65X125C

Motor DNm DNa

PN16 PN16

NRM2 80X65X125B

NRM2 80X65X125A

NRM2 80X65X160C

NRM2 80X65X160B

NRM2 80X65X160A

NRM2 80X65X200D

NRM2 80X65X200C

fig.

1

1

1

1

1

1

1

2

a h1

160

160

160

160

160

160

180

180

h2

180

180

180

200

200

200

225

225

b

65

65

65

65

65

65

55

55

m1

125

125

125

125

125

125

125

298

m2

95

95

95

95

95

95

95

241

n1 n2

280

280

280

280

280

280

320

320

s

14

14

14

14

14

14

14

14

C

12

12

12

12

12

12

12

22

W L

525

535

535

640

640

640

640

800

Z B

300

300

300

325

325

325

345

400

H

340

340

340

360

360

360

405

405

E

159

159

159

184

184

184

184

230

44

51

51,5

70

77

83

87,5

122

100

100

100

100

100

100

100

100

80

80

80

80

80

80

80

80

65

65

65

65

65

65

65

65

100

112

112

132

132

132

132

160

NRM2 80X65X200B 2 180 225 55 298 241 320 14 22 800 400 405 230 1401008065160

NRM2 80X65X250D 2 180 250 55 298 241 320 14 22 810 365 430 230 1441008065180

NRM2 80X65X250C 2 200 250 60 345 305 360 18 24 905 400 450 257 1721008065200

NRM2 80X65X250B 2 200 250 60 345 305 360 18 24 905 400 450 257 1901008065200

280

280

293

325

325

20

20

20

20

20

17 12,5

20 15

20 15

36 35,5 34,5 3336,3 3036,5

57 56,5 56 55 53,5

51 50 49,5 48,5 46,5

1750

11

19

20,5

33

31,5

53

66

75

27

51

43,5

16

29

60

70

23

48

39,5

24

53

64

19

42,5

35

NR

M

220/380

380/415

220/380

380/415

220/380

380/415

220/380

380/415

380/415

380/415

380/415

380/415

380/415

380/415

380/415

380/415

15,2/8,8

8,8

19,5/11,3

11,3

23,3/13,5

13,5

39/22,5

22,5

27

32

32

38

45

45

58

71

212

212

212

212

212

212

250

280

280

280

318

318

UNI PN 16 DN a1 b1 c1 d1 e1

65 122 145 185 4 1880 138 160 200 8 18

Flange

n° d1 holes ø e1

DN a 1 b 1 c 1

48 54 60 75 90 120 1354539 4236 105

Dis

char

ge h

ead

in m

eter

s

Page 85: Electric Pumps Catalogue

86

NRM2 100X80

PUMP PERFORMANCE

MODELCODE

NominalPower

kWHP

Amp.3 X 400 V

QL/1'

m3/h

2250 2500 2750 3000 3500 4500 50002000VOLTAGE( V )

NRM2 100X80X160DAT0712718 16,5 1519,522 2123

29 27,5 26 24,53132,5 31,833,3

41 39 37 344345,5 44,546,5

54 52,5 51 485556,5 5656,8

63 61 58 556567 6668

1500 17501250

AT07128

AT07130

AT07132

AT07136

AT07138

AT07140

AT07142

AT07146

NRM2 100X80X160D

NRM2 100X80X160C

NRM2 100X80X160B

NRM2 100X80X200D

NRM2 100X80X200C

NRM2 100X80X200B

NRM2 100X80X200A

NRM2 100X80X250D

13,5 10

17 12,5

20 15

25 18,5

50 37

50 37

TABLE OF SIZES AND WEIGHTS

ModelDimensions mm. Weight

NRM2 100X80X160D

Motor DNm DNa

PN16 PN16

NRM2 100X80X160C

NRM2 100X80X160B

NRM2 100X80X200D

NRM2 100X80X200C

NRM2 100X80X200B

NRM2 100X80X200A

NRM2 100X80X250D

fig.

1

1

1

2

2

2

2

2

a h1

180

180

180

180

180

200

200

200

h2

225

225

225

250

250

250

250

280

b

65

65

65

55

55

60

60

60

m1

125

125

125

398

398

345

345

345

m2

95

95

95

241

241

305

305

305

n1

320

320

320

320

320

360

360

360

n2

250

250

250

280

280

318

318

318

s

14

14

14

14

14

18

18

18

C

14

14

14

22

22

24

24

24

W L

665

665

665

835

835

930

930

930

Z B

345

345

345

400

400

400

400

400

H

405

405

405

450

450

450

450

480

E

184

184

184

230

230

257

257

257

74

81,5

88,5

132

150

192

210

196

125

125

125

125

125

125

125

125

100

100

100

100

100

100

100

100

80

80

80

80

80

80

80

80

132

132

132

160

180

200

200

200

30 22

40 30

24

34

47

57 42

47

1000 4000

49 47 45 435153 525455 37

35 33 30,5 283740 38,54142

23 21,5 20 18,524,527 262828,5

293

293

325

325

325

20

20

20

20

20

220/380

380/415

380/415

380/415

380/415

380/415

380/415

380/415

380/415

39/22,5

22,5

27

32

38

45

58

71

71

n° d1 holes ø e1

DN a 1 b 1 c 1

UNI PN 16 DN a1 b1 c1 d1 e1

80 138 160 200 8 18100 158 180 220 8 18

Flange

fig.1 fig.2

135 150 165 180 210 270 30012090 1057560 240

Dis

char

ge h

ead

in m

eter

s

Page 86: Electric Pumps Catalogue

NRM2 125X100

87

PUMP PERFORMANCE

MODELCODE

NominalPower

kWHP

Amp.3 X 400 V

QL/1'

m3/h

2250 2500 2750 3000 3500 4500 50002000VOLTAGE( V )

NRM2 125X100X200DAT07154 36 34,5 33 31,537 2839 38

52 51 50 4953 4654 53,5

1500 17501250

AT07156

AT07158

NRM2 125X100X200C

NRM2 125X100X200B

30 22

50 37

TABLE OF SIZES AND WEIGHTS

ModelDimensions mm. WeightMotor DNm DNa

PN16 PN16 fig. a h1 h2 b m1 m2 n1 n2 s C W L Z B H E

2 180 280 55 298 241 320 318 14 22 835 400 460 230 160125125100180

2 200 280 60 345 305 360 318 18 24 930 400 480 257 202125125100200

2 200 280 60 345 305 360 318 18 24 930 400 480 257 220125125100200

293

325

325

20

20

20

4000

43

40 30 45 44 42 4046 3847 46,5 33,5 28,4

38 34

1000

24

NRM2 125X100X200D

NRM2 125X100X200C

NRM2 125X100X200B NR

M

380/415

380/415

380/415

45

71

58

n° d1 holes ø e1

DN a 1 b 1 c 1

UNI PN 16 DN a1 b1 c1 d1 e1

100 158 180 220 8 18

Flange

125 188 210 250 8 18

135 150 165 180 210 270 30012090 10575 24060

Dis

char

gehe

adin

met

ers

Page 87: Electric Pumps Catalogue

NRM4

88

Performance range

Q:(L/min)

4

0

H(m)

100 200 400 1000 2000 4000 10000

5

6

8

10

15

20

25

30

40

50x32x250

50x32x160

50x32x200

50x32x125

65x40x250

65x40x200

65x40x160

65x40x125

80x65x250

80x65x200

80x65x125

80x65x160

100x80x250

100x80x200

100x80x160

125x100x200

125x100x250

150x125x250

150x125x200

250x200x250

250x150x200

4 POLES

65x50x250

65x50x200

65x50x160

65x50x125

Page 88: Electric Pumps Catalogue

NRM4 50X32

89

TABLE OF SIZES AND WEIGHTS

ModelDimensions mm. WeightMotor DNm DNa

PN16 PN16

PUMP PERFORMANCE

MODELCODE

NominalPower

kWHP

Amp.3 X 400 V

QL/1'

m3/h

150 175 200 225 250 300125VOLTAGE( V )

NRM4 50X32X125YAT07165 4 3,54,4

7,7 6,9 5,88,39,2 8,99,4

13,3 12,7 11,8 1013,8 914,5 14,3

20,5 19,5 18 16,521 1521,5

75 10050

AT07167

AT07173

AT07177

AT07179

AT07183

NRM4 50X32X125X

NRM4 50X32X160X

NRM4 50X32X200Y NRM4 50X32X200X

NRM4 50X32X250Y

NRM4 50X32X250X

0,33 0,25

0,5 0,37

1,5 1,1

2 1,5

275

8

13

a h1

112

112

132

160

160

180

180

h2

140

140

160

180

180

225

225

b

50

50

50

50

50

65

65

m1

100

100

100

100

100

125

125

m2

70

70

70

70

70

95

95

n1

190

190

240

240

240

320

320

n2

140

140

190

190

190

250

250

s

14

14

14

14

14

14

14

C

12

12

12

12

12

12

12

L

405

405

405

425

425

485

485

B

205

205

240

255

255

320

320

H

252

252

292

340

340

405

405

E

107

107

107

118

118

149

149

19,5

19,5

23

31

30

47

49

80

80

80

80

80

100

100

50

50

50

50

50

50

50

32

32

32

32

32

32

32

71

71

71

80

80

90

90

11,3 10,6 9,8 811,9 712,8 12,413 6

4,5 3,9 35,26 5,86,2

17 16 14,5 1317,5 11,518,5 18,5

0,33 0,25

1,25 0,9

1 0,75

4,7

10,9

9

2,23

22

NRM4 50X32X125Y

NRM4 50X32X125X

NRM4 50X32X160X

NRM4 50X32X200Y

NRM4 50X32X200X

NRM4 50X32X250Y

NRM4 50X32X250X

AT07185

NR

M

220/380

220/380

220/380

220/380

220/380

220/380

220/380

1,46/0,85

1,46/0,85

2/1,15

3,3/1,9

4,2/2,4

4,5/3,6

6,2/3,6

n° d1 holes ø e1

DN a 1 b 1 c 1

UNI PN 16 DN a1 b1 c1 d1 e1

32 78 100 140 4 1850 102 125 165 4 18

Flange

9 10,5 12 13,5 15 187,54,5 63 16,5

Dis

char

ge h

ead

in m

eter

s

Page 89: Electric Pumps Catalogue

90

NRM4 65X40

PUMP PERFORMANCE

TABLE OF SIZES AND WEIGHTS

ModelDimensions mm. WeightMotor DNm DNa

PN16 PN16 a h1

112

112

132

160

160

180

180

h2

140

140

160

180

180

225

225

b

50

50

50

50

50

65

65

m1

100

100

100

100

100

125

125

m2

70

70

70

70

70

95

95

n1

210

210

240

265

265

320

320

n2

160

160

190

212

212

250

250

s

14

14

14

14

14

14

14

C

12

12

12

12

12

12

12

L

405

405

405

485

485

485

525

B

230

230

230

242

242

325

325

H

252

252

292

340

340

405

405

E

107

107

107

149

149

149

159

20,5

21,5

25

36

36

47,5

54

80

80

80

100

100

100

100

65

65

65

65

65

65

65

40

40

40

40

40

40

40

71

71

71

90

90

90

100

MODELCODE

NominalPower

kWHP

Amp.3 X 400 V

QL/1'

m3/h

200 225 250 275 300 400175VOLTAGE( V )

NRM4 65X40X125YAT07189 4,5 4,34,6

7,7 7,3 6,988,6 8,38,8

13 12,5 12 1013,4 8,314 13,8

21,4 21 20,5 2021,7 19,522

125 150100

AT07191

AT07197

AT07203

AT07205

AT07209

NRM4 65X40X125X

NRM4 65X40X160X

NRM4 65X40X200Y NRM4 65X40X200X

NRM4 65X40X250Y

NRM4 65X40X250X

0,33 0,25

0,7 0,5

2 1,5

3 2,2

350

6

18,5

11,2 10,7 10,1 8,511,7 712,5 12,112,7

5,8 5,5 5,266,2 6,16,3

17 16,6 16,2 15,617,4 1518 17,7

0,5 0,37

1,5 1,1

1,5 1,1

6,4

11

9,5

3,94,1

22,3AT07211

14,2

18,3

22,5

5,9 4,5

4,9 4,6 3

3,6 3,3 2,9 2,4

13,7 12

17

NRM4 65X40X125Y

NRM4 65X40X125X

NRM4 65X40X160X

NRM4 65X40X200Y

NRM4 65X40X200X

NRM4 65X40X250Y

NRM4 65X40X250X

220/380

220/380

220/380

220/380

220/380

220/380

220/380

1,46/0,85

2/1,15

2,8/1,6

4,5/3,6

4,5/3,6

6,2/3,6

8,9/5,1

n° d1 holes ø e1

DN a 1 b 1 c 1

UNI PN 16 DN a1 b1 c1 d1 e1

40 88 110 150 4 1865 122 145 185 4 18

Flange

12 13,5 15 16,5 18 2410,57,5 96 21

Dis

char

ge h

ead

in m

eter

s

Page 90: Electric Pumps Catalogue

NRM4 65X50

91

PUMP PERFORMANCE

TABLE OF SIZES AND WEIGHTS

ModelDimensions mm. WeightMotor DNm DNa

PN16 PN16 a h1

132

132

160

160

160

160

180

h2

160

160

180

180

180

180

225

b

50

50

50

50

50

50

65

m1

100

100

100

100

100

100

125

m2

70

70

70

70

70

70

95

n1

240

240

265

265

265

265

320

n2

190

190

212

212

212

212

250

s

14

14

14

14

14

14

14

C

12

12

12

12

12

12

14

L

425

425

445

445

485

485

525

B

246

246

269

269

285

285

333

H

292

292

340

340

360

360

405

E

107

107

118

118

149

149

159

25

26

32

33

38

40

57

100

100

100

100

100

100

100

65

65

65

65

65

65

65

50

50

50

50

50

50

50

71

71

80

80

90

90

100

180 225 65 125 95 320 250 14 14 525 333 405 159 631006550100

NRM4 65X50X125Y

NRM4 65X50X125X

NRM4 65X50X160Y

NRM4 65X50X160X

NRM4 65X50X200Y

NRM4 65X50X200X

NRM4 65X50X250Y

NRM4 65X50X250X

MODELCODE

NominalPower

kWHP

Amp.3 X 400 V

QL/1'

m3/h

350 400 500 550 600 700300VOLTAGE( V )

NRM4 65X50X125YAT07215

250 275225

AT07217

AT07221

AT07223

AT07227

AT07229

NRM4 65X50X125X

NRM4 65X50X160Y

NRM4 65X50X160X NRM4 65X50X200Y

NRM4 65X50X200X

NRM4 65X50X250Y

0,5 0,37

1 0,75

2 1,5

3 2,2

650

0,7 0,5

1,5 1,1

1,25 0,9

AT07233

AT07235 NRM4 65X50X250X 4 3

5,2

8,2

12,4

18,5

9

6,2

14,3

22,5

450200175150

5,1

8

12,2

18,3

8,9

6,1

14,2

22,4

5

7,9

12

18,1

8,8

6

14,1

22,3

4,9

7,8

11,8

17,8

8,7

5,9

14

22,2

4,8

7,7

11,5

17,5

8,6

5,8

13,7

22

4,5

7,4

10,8

17

8,4

5,5

13

21,5

4,1

7

10

16,5

8,1

5,2

12,3

20,9

3,6

6,6

9

15,5

7,7

4,9

11,3

20,2

6

8

14,5

7,2

10,2

19,4

5

7

13,5

6,5

9,1

18,5

12,5

7,8

17,5

11,5

6,4

16,3

10

5

15

5,3

6,3

5,3

6,4

3

4,4

4

5,8

5,5

NR

M

220/380

220/380

220/380

220/380

220/380

220/380

220/380

220/380

2/1,15

2,8/1,6

3,3/1,9

4,2/2,4

4,5/3,6

6,2/3,6

8,9/5,1

11/6,4

n° d1 holes ø e1

DN a 1 b 1 c 1

UNI PN 16 DN a1 b1 c1 d1 e1

50 102 125 165 4 1865 122 145 185 4 18

Flange

21 24 30 33 36 421815 16,513,5 39271210,59

Dis

char

ge h

ead

in m

eter

s

Page 91: Electric Pumps Catalogue

92

NRM4 80X65

PUMP PERFORMANCE

TABLE OF SIZES AND WEIGHTS

ModelDimensions mm. WeightMotor DNm DNa

PN16 PN16 a h1

160

160

160

180

180

200

200

h2

180

200

200

225

225

250

250

b

65

65

65

65

65

80

80

m1

125

125

125

125

125

160

160

m2

95

95

95

95

95

120

120

n1

280

280

280

320

320

360

360

n2

212

212

212

250

250

280

280

s

14

14

14

14

14

14

14

C

12

12

12

14

14

14

14

L

445

485

485

525

525

535

640

B

286

288

288

328

328

365

365

H

340

360

360

405

405

450

450

E

118

149

149

159

159

159

184

32

37,5

40

51

57

80

90

100

100

100

100

100

100

100

80

80

80

80

80

80

80

65

65

65

65

65

65

65

80

90

90

100

100

112

132

MODELCODE

NominalPower

kWHP

Amp.3 X 400 V

QL/1'

m3/h

700 900 1000 1100 1300600VOLTAGE( V )

NRM4 80X65X125XAT07241

500 550450

AT07245

AT07247

AT07251

AT07253

AT07257

NRM4 80X65X160Y

NRM4 80X65X160X

NRM4 80X65X200Y NRM4 80X65X200X

NRM4 80X65X250Y

NRM4 80X65X250Y

1 0,75

2 1,5

5,5 4

1200

1,5 1,1

4 3

3 2,2

AT07258

AT07259 NRM4 80X65X250X

5,6

10

12,5

8,4

800400350300

5,5

9,9

12,4

8,3

5,3

9,8

15,2

12,3

8,2

19,5

23

5,1

9,6

15,1

12,2

8,1

19,3

22,8

4,9

9,4

15

12,1

8

19,1

22,6

4,5

9

14,6

11,7

7,5

18,5

22,2

4

8,5

14,3

11,1

6,8

17,5

21,4

13,6

10,5

16,5

20,6

12,8

9,6

15,5

19,7

14

18,7

12,5

17,5 16

5,7

8,5

5,8

8,6 6

12

AT07260 NRM4 80X65X250X5,57,5

10,110,2

5

7,7

8,5

11

10,5

14

1400

NRM4 80X65X125X

NRM4 80X65X160Y

NRM4 80X65X160X

NRM4 80X65X200Y

NRM4 80X65X200X

NRM4 80X65X250Y

NRM4 80X65X250X

220/380

220/380

220/380

220/380

220/380

220/380

380/415

220/380

380/415

3,3/1,9

4,5/3,6

6,2/3,6

8,9/5,1

11/6,4

15,2/8,8

8,8

30/17,3

17,3

n° d1 holes ø e1

DN a 1 b 1 c 1

UNI PN 16 DN a1 b1 c1 d1 e1

65 122 145 185 4 1880 138 160 200 8 18

Flange

42 54 60 66 783630 3327 7248242118 84

Dis

char

ge h

ead

in m

eter

s

Page 92: Electric Pumps Catalogue

NRM4 100X80

93

PUMP PERFORMANCE

MODELCODE

NominalPower

kWHP

Amp.3 X 400 V

QL/1'

m3/h

1200 1300 1500 1750 20001100VOLTAGE( V )

NRM4 100X80X160YAT07263

900 1000800

AT07265

AT07269

AT07271

AT07272

AT07275

NRM4 100X80X160X

NRM4 100X80X200Y

NRM4 100X80X200X NRM4 100X80X200X

NRM4 100X80X250Y

NRM4 100X80X250Y

2 1,5

4 3

7,5 5,5

2250

3 2,2

5,5 4

AT07276

AT07277 NRM4 100X80X250X10 7,5

7,5

11,7

14,2

9,5

1400700650600

7,3

11,5

14

9,3

7

11,3

13,8

19

9

6,7

11

13,5

18,5

8,8

6,4

10,5

13,1

18

8,5

6,1

10

12,7

17,5

8,2

5,8

9,5

12,2

17

7,9

5,4

9

11,6

16,5

7,5

8,5

11

16

7

9

14 12

7,6

9,6

7,7

9,7

5

7,1

6,5

AT07278 NRM4 100X80X250X22 21,9 21,7 21,5 21,3 21 20 19 17 14,5

11,9

14,4

12

14,5

6

TABLE OF SIZES AND WEIGHTS

ModelDimensions mm. WeightMotor DNm DNa

PN16 PN16 a h1

180

180

180

180

200

200

h2

225

225

250

250

280

280

b

65

65

65

65

80

80

m1

125

125

125

125

160

160

m2

95

95

95

95

120

120

n1

320

320

345

345

400

400

n2

250

250

280

280

315

315

s

14

14

14

14

18

18

C

14

14

12

12

14

14

L

510

510

560

550

665

665

B

330

330

355

355

400

400

H

405

405

430

430

480

480

E

149

149

159

159

184

184

45

51

73

66

96

106

125

125

125

125

125

125

100

100

100

100

100

100

80

80

80

80

80

80

90

100

100

112

132

132

NRM4 100X80X160Y

NRM4 100X80X160X

NRM4 100X80X200Y

NRM4 100X80X200X

NRM4 100X80X250Y

NRM4 100X80X250X

NR

M

220/380

220/380

220/380

220/380

380/415

220/380

380/415

220/380

380/415

6,2/3,6

8,9/5,1

11/6,4

15,2/8,8

8,8

19,5/11,3

11,3

30/17,3

17,3

n° d1 holes ø e1

DN a 1 b 1 c 1

UNI PN 16 DN a1 b1 c1 d1 e1

80 138 160 200 8 18100 158 180 220 8 18

Flange

72 78 90 105 1206654 6048 13584423936

Dis

char

ge h

ead

in m

eter

s

Page 93: Electric Pumps Catalogue

94

NRM4 125X100

PUMP PERFORMANCE

Dis

char

ge h

ead

in m

eter

s

MODELCODE

NominalPower

kWHP

Amp.3 X 400 V

QL/1'

m3/h

VOLTAGE( V )

NRM4 125X100X200YAT07281

AT07282

AT07283

AT07284

AT07287

AT07288

NRM4 125X100X200Y

NRM4 125X100X200X

NRM4 125X100X200X NRM4 125X100X250Y

NRM4 125X100X250Y

5,5 4

7,5 5,5

12,5 9,2

10 7,5

AT07290 NRM4 125X100X250X

1750 2250 2500 275015001300 14001200 3000200011001000900

12,2

14,4

19,5

22

14,5

12,4

19,3

21,9

11,8

14

19,1

21,8

14,2

12

18,9

21,7

11,4

13,6

18,7

21,6

13,8

11,6

18,5

21,5

10,3

12,8

17,5

20,5

13,4

11,2

16,5

19,5

8,2

11

15,2

18,5

12

9,3

14

17

4,8

8,5

12

15

10

6,8

13

TABLE OF SIZES AND WEIGHTS

ModelDimensions mm. WeightMotor DNm DNa

PN16 PN16 a h1

200

200

225

225

h2

280

280

280

280

b

80

80

80

80

m1

160

160

160

160

m2

120

120

120

120

n1

360

360

400

400

n2

280

280

315

315

s

18

18

18

18

C

14

14

14

14

L

560

665

675

675

B

385

385

420

420

H

480

480

505

505

E

1559

184

184

184

78

90

112

118

125

125

140

140

125

125

125

125

100

100

100

100

112

132

132

132

NRM4 125X100X200Y

NRM4 125X100X200X

NRM4 125X100X250Y

NRM4 125X100X250X

220/380

380/415

220/380

380/415

220/380

380/415

380/415

15,2/8,8

8,8

19,5/11,3

11,3

30/17,3

17,3

19

n° d1 holes ø e1

DN a 1 b 1 c 1

UNI PN 16 DN a1 b1 c1 d1 e1

100 158 180 220 8 18125 188 210 250 8 18

Flange

105 135 150 1659078 8472 180120666054

Page 94: Electric Pumps Catalogue

Dis

char

ge h

ead

in m

eter

s

NRM4 150X125

95

PUMP PERFORMANCE

MODELCODE

NominalPower

kWHP

Amp.3 X 400 V

QL/1'

m3/h

VOLTAGE( V )

NRM4 150X125X200WAT07403

AT07404

AT07405

AT07406

AT07407

AT07408

NRM4 150X125X200W

NRM4 150X125X200Z

NRM4 150X125X200Z NRM4 150X125X200Y

NRM4 150X125X200Y

7,5 5,5

10 7,5

10 7,5

AT07410 NRM4 150X125X200X

20 15

1800

NRM4 150X125X250ZAT07416

AT07418 NRM4 150X125X250Y

AT07420 NRM4 150X125X250X

2000 2500 3000 3500 4000 4500 5000

12,5 9,2

15 11

20 15

10,4

11,6

13

14,3

17

10,2

11,5

12,8

19,8

14,2

16,6

20,8

9,4

10,9

12,3

19

13,8

15,7

19,7

8,3

9,9

11,6

18

13,2

14,4

18,6

6,8

8,6

10,5

16,6

12,3

12,6

17

7

9,1

15

11,1

15,2

7,5

9,6

13,2

8

TABLE OF SIZES AND WEIGHTS

ModelDimensions mm. WeightMotor DNm DNa

PN16 PN16 a h1

250

250

250

250

250

250

h2

315

315

315

315

355

355

b

80

80

80

80

80

80

m1

160

160

160

160

160

160

m2

120

120

120

120

120

120

n1

400

400

400

400

400

400

n2

315

315

315

315

315

315

s

18

18

18

18

18

18

C

14

14

14

14

14

14

L

700

700

700

700

700

855

B

470

470

470

470

470

470

H

565

565

565

565

605

605

E

255

255

255

255

255

255

124

134

134

140

162

190

140

140

140

140

140

140

150

150

150

150

150

150

125

125

125

125

125

125

132

132

132

132

132

160

NRM4 150X125X200W

NRM4 150X125X200Z

NRM4 150X125X200Y

NRM4 150X125X200X

NRM4 150X125X250Z

NRM4 150X125X250Y

250 355 80 160 120 400 315 18 14 855 470 605 255 190140150125160 NRM4 150X125X250X

NR

M

220/380

380/415

220/380

380/415

220/380

380/415

380/415

380/415

380/415

380/415

19,5/11,3

11,3

30/17,3

17,3

30/17,3

17,3

19

22,5

27,8

27,8

n° d1 holes ø e1

DN a 1 b 1 c 1

UNI PN 16 DN a1 b1 c1 d1 e1125 188 210 250 8 18

Flange

150 212 240 285 8 22

108 120 150 180 210 240 270 300

Page 95: Electric Pumps Catalogue

96

NRM4 200X150

PUMP PERFORMANCE

MODELCODE

NominalPower

kWHP

Amp.3 X 400 V

QL/1'

m3/h

VOLTAGE( V )

NRM4 200X150X200WAT07423

AT07424

AT07426

AT07428

NRM4 200X150X200W

NRM4 200X150X200Z

NRM4 200X150X200Y

NRM4 200X150X200X

10 7,5

12,5 9,2

20 15

15 11

AT07430

700060005000 55004500400030002500

11,5

10,4

TABLE OF SIZES AND WEIGHTS

ModelDimensions mm. WeightMotor DNm DNa

PN16 PN16 a h1

280

280

280

280

h2

400

400

400

400

b

100

100

100

100

m1

200

200

200

200

m2

155

155

155

155

n1

550

550

550

550

n2

450

450

450

450

s

24

24

24

24

C

22

22

22

22

L

855

855

855

875

B

550

550

550

550

H

680

680

680

680

E

295

295

295

295

167

173

175

203

160

160

160

160

200

200

200

200

150

150

150

150

132

132

132

160

NRM4 200X150X200W

NRM4 200X150X200Z

NRM4 200X150X200Y

NRM4 200X150X200X

3500

13,3

14,5

10,9

9,7

12,6

14

10,2

8,9

12

13,2

9,3

7,9

11,1

12,5

8,3

6,7

10,1

11,6

7

5,5

9

10,6

5,8

7,6

9,4 8

380/415

380/415

380/415

380/415

17,3

19

22,5

27,8

30/17,3

n° d1 holes ø e1

DN a 1 b 1 c 1

150200

212268

240295

285340

88

2222

UNI PN 16 DN a1 b1 c1 d1 e1

Flange

450360300 330270240180150 210

Dis

char

ge h

ead

in m

eter

s

220/380

Page 96: Electric Pumps Catalogue

NRM4 250X200

97

PUMP PERFORMANCE

MODELCODE

NominalPower

kWHP

Amp.3 X 400 V

QL/1'

m3/h

VOLTAGE( V )

NRM4 250X200X250WAT07434

AT07436

AT07438

AT07440

NRM4 250X200X250Z

NRM4 250X200X250Y

NRM4 250X200X250X

4500 5000 5500 6000 6500 7000 8000 9000

13,5

18,6

13

18

12,4

17,6

11,8

17

11,2

16,4

TABLE OF SIZES AND WEIGHTS

ModelDimensions mm. WeightMotor DNm DNa

PN16 PN16 a h1

315

315

315

315

h2

450

450

450

450

b

100

100

100

100

m1

200

200

200

200

m2

155

155

155

155

n1

550

550

550

550

n2

450

450

450

450

s

24

24

24

24

C

22

22

22

22

L

1000

1000

1000

1000

B

630

630

630

630

H

765

765

765

765

E

350

350

350

350

278

278

300

300

200

200

200

200

250

250

250

250

200

200

200

200

180

180

180

180

NRM4 250X200X250W

NRM4 250X200X250Z

NRM4 250X200X250Y

NRM4 250X200X250X

14,6 14 13,5 13 12,4

17 16,5 16 15,4 14,7

14,3 12,5 10,6

12,4 10,5

15,8

14

11,7

10,5

10,2

9

10000

18,5

22

18,5

22

25

30

25

30

NR

M

380/415

380/415

380/415

380/415

32

32

39

39

n° d1 holes ø e1

DN a 1 b 1 c 1

UNI PN 16 DN a1 b1 c1 d1 e1

Flange

200250

268320

295350

340395

88

2225

270 300 330 360 390 450 480 540 600

Dis

char

gehe

adin

met

ers

Page 97: Electric Pumps Catalogue

NRBCENTRIFUGAL PUMPS WITH BASE-PLATE AND COUPLING.NORMALIZED DIMENSIONS DIN 24255 - UNI 7467 - EN733

99

Page 98: Electric Pumps Catalogue

NRBHORIZONTAL CENTRIFUGAL PUMPS WITH BASE-PLATE ANDCOUPLING (2 AND 4 POLES)

NRB pumps, centrifugal single stage horizontal, are designed according toDIN24255/EN733 standards, in order to have maximum interchangeability betweencomponents. The impeller is dynamically and hydraulically balanced. The shaft isduly oversized to guarantee required stiffness and it is supported by greaselubricated sturdy ball bearings.

• STRONG AND RESISTANT• WIDE RANGE

100

Usage limitations- Temperature of pumped liquid -10°C+130°C- Capacity up to 330 m3/h- Dynamic head up to 95m- Max suction pressure:4 bar- Max operating pressure:10 bar- Working temperature: -10°C +130°C

Applications– Aqueducts– Irrigation– Water distribution– Industrial applications

Motor– Enclosed, externally ventilated– Level of protection IP44– Class F insulation– Building B3– Three phase power supply– Speed of rotation 2850 rpm– Suitable for continuous use

Component

Pump body

Impeller

Material

Cast iron EN GJL 200 (ex G20)

Cast iron EN GJL 200 (ex G20)Bronze (on request)

DESIGN FEATURES

12

3

4

5

Casing cover Cast iron EN GJL 200 (ex G20)

Bearing housing Cast iron EN GJL 200 (ex G20)

Shaft Stainless steel AISI420

6 Mechanical seal Ceramic/graphite/EPDMSilicon carbide/silicon carbide/EPDM

Page 99: Electric Pumps Catalogue

NR

B 2

2 POLES

32X250

40020010050201065

6

8

10

20

30

40

60

80

100

125

32X200

32X160

32X120

40X250

40X200

40X160

40X120

50X250

50X200

50X160

50X120

65X250

65X200

65X160

65X120

80X250

80X200

80X160

100X250

100X200

NRB2

101

Performance range

Q:(m3/h)

H(m)

Page 100: Electric Pumps Catalogue

MODELCODE

NominalPower

kWHP

Amp.3 X 400 V

QL/1'

m3/h

300 350 400 450250VOLTAGE( V )

NRB2 32X120 CPA021000 914,5 1215,5

11,51520 1821

16,5 1319,523,5 2224,5

2225,530 2831,5

262933,5 31,534,5

30 26,532,536,5 3538

39 3542,546,5 44,547,5

55 52,5 49 4557,560,5 5961

80 76 70 638385 84,585,5

150 200100

PA021010

PA021020

PA021030

PA021040

PA020020

PA020720

PA020900

PA020750

PA020010

PA020400

PA020330

1 0,75

1,5 1,1

2 1,5

3 2,2

4 3

4 3

5,5 4

10 7,5

15 11

Dis

char

ge h

ead

in m

eter

s

230/400

230/400

230/400

230/400

230/400

230/400

230/400

400

400

400

400

400

3,3/1,9

4,7/2,7

6,1/3,5

8,5/4,9

11,1/6,4

11,1/6,4

14,8/8,5

15

18

11,3

18 21 24 27159 126

NRB2 32X120 B

NRB2 32X120 A

NRB2 32X160 C

NRB2 32X160 B

NRB2 32X160 A

NRB2 32X200 C

NRB2 32X200 B

NRB2 32X200 A

NRB2 32X250 C

NRB2 32X250 B

NRB2 32X250 A

7,5 5,5

12,5 9,2

20 15

49,5 46 42 3751,555 53,556

68 62 567274,5 7475

88 84 79 739091,5 9192

102

NRB2 32

PUMP PERFORMANCE

a f h2 b1 b2 l1 l2 l3 h h3 xa

TABLE OF SIZES AND WEIGHTS

ModelDimension mm.

WeightMotor DNm DNa

PN16 PN16Lm yType

NRB2 32X120 A

NRB2 32X120 B

NRB2 32X120 C

NRB2 32X160 A

NRB2 32X160 B

NRB2 32X160 C

NRB2 32X200 A

NRB2 32X200 B

NRB2 32X200 C

NRB2 32X250 A

NRB2 32X250 B

NRB2 32X250 C

90 S2

80 B2

80 A2

100 L2

100 L2

112 MC2

112 MB2

132 MC2

112 M2

132 MD2

132 MB2

302

280

280

369

369

327

386

386

498

386

498

498

16

16

16

22

22

16

22

22

24

22

24

24

32

32

32

32

32

32

32

32

32

32

32

32

50

50

50

50

50

50

50

50

50

50

50

50

80

80

80

80

80

80

80

80

100

80

100

100

360

360

360

360

360

360

360

360

360

360

360

360

140

140

140

160

160

160

180

180

225

180

225

225

240

240

240

240

240

240

240

240

350

240

350

350

170

170

170

170

170

170

170

170

280

170

280

280

850

850

850

850

850

850

850

850

950

850

950

950

800

800

800

800

800

800

800

800

900

800

900

900

25

25

25

25

25

25

25

25

25

25

25

25

197

197

197

217

217

217

245

245

280

245

280

280

85

85

85

85

85

85

85

85

100

85

100

100

100

100

100

100

100

100

100

100

100

100

100

100

65

63

61

80

80

74

98

95

156

95

164

151

90 L2

20,5

27

Page 101: Electric Pumps Catalogue

MODELCODE

NominalPower

kWHP

Amp.3 X 400 V

QL/1'

m3/h

VOLTAGE( V )

NRB2 40X120 CPA021050

PA021060

PA021070

PA021080

PA021090

PA020210

PA020350

PA020150

PA020680

PA020060

PA020810

PA020340

NRB2 40X120 B

NRB2 40X120 A

NRB2 40X160 C

NRB2 40X160 B

NRB2 40X160 A

NRB2 40X200 C

NRB2 40X200 B

NRB2 40X200 ANRB2 40X250 C

NRB2 40X250 B

NRB2 40X250 A

2 1,5

3 2,2

4 3

4 3

5,5 4

7,5 5,5

12,5 9,2

20 15

Dis

char

ge h

ead

in m

eter

s

NR

B 2

230/400

230/400

230/400

230/400

230/400

230/400

400

400

400

400

400

400

6,1/3,5

8,5/4,9

11,1/6,4

11,1/6,4

14,8/8,5

14,8/8,5

11,3

15,0

18,0

20,5

27,0

32,0

18

21,5

25

31

200

34

37

43,5

52

57

73

82,5

93

17,5

21

24,5

30

250

33

36,5

43

51

56,5

72

82

92,5

17

20,5

24

29

300

12

32

35,5

42

50

55,5

71

81

91

15,5

20

23,5

28

350

15

31

34,5

40

49

54

70

80

90

14

19

23

26,5

400

18

30

33,5

38

47

53

67,5

79

88

17,5

22

25

450

21

28,5

32,5

36

45

51

65

77

86

15,5

20,5

22,5

500

24

26,5

31

33

43

49

62

75

84

18,5

19,5

550

27

24,5

29

29

40

47

57

72

81

600

30

21,5

26,5

24

37

44

51

68

77

650

33

33

41

44

63

72

700

36

28

37

56

67

750

39

92

5,5 4

10 7,5

15 11

25 18,5

NRB2 40

103

PUMP PERFORMANCE

NRB2 40X120 A

NRB2 40X120 B

NRB2 40X120 C

NRB2 40X160 A

NRB2 40X160 B

NRB2 40X160 C

NRB2 40X200 A

NRB2 40X200 B

NRB2 40X200 C

NRB2 40X250 A

NRB2 40X250 B

NRB2 40X250 C

a f h2 b1 b2 l1 l2 l3 h h3 xa

TABLE OF SIZES AND WEIGHTS

ModelDimension mm.

WeightMotor DNm DNa

PN16 PN16Lm yType

100 L2

90 L2

90 S2

112 M2

112 M2

132 MB2

112 MC2

132 MD2

112 MB2

160 L2

132 MC2

369

327

302

386

386

369

498

386

498

386

645

498

22

16

16

22

22

22

24

22

24

22

24

24

40

40

40

40

40

40

40

40

40

40

40

40

80

80

80

80

80

80

100

100

100

100

100

100

360

360

360

360

360

360

360

360

360

360

360

360

140

140

140

160

160

160

180

180

225

180

225

225

240

240

240

240

240

240

280

280

350

280

350

350

170

170

170

170

170

170

210

210

280

210

280

280

850

850

850

850

850

850

950

950

950

950

1120

950

800

800

800

800

800

800

900

900

900

900

1070

900

25

25

25

25

25

25

25

25

25

25

25

25

197

197

197

217

217

217

255

255

280

255

280

280

85

85

85

85

85

85

95

95

100

95

100

100

100

100

100

100

100

100

100

100

100

100

100

100

75

69

67

91

91

81

128

109

173

112

282

165

100 L2

65

65

65

65

65

65

65

65

65

65

65

65

42 45

Page 102: Electric Pumps Catalogue

MODELCODE

NominalPower

kWHP

Amp.3 X 400 V

QL/1'

m3/h

VOLTAGE( V )

NRB2 50X120 CPA021100 18

22

25,5

27,5

33

37

47

57,5

400

PA021110

PA021120

PA021130

PA021140

PA020070

PA020190

PA020050

PA020090

PA020880

PA020130

PA020180

3 2,2

4 3

5,5 4

5,5 4

7,5 5,5

10 7,5

10 7,5

15 11

25 18,5

Dis

char

ge h

ead

in m

eter

s

230/400

230/400

230/400

230/400

400

400

400

400

400

400

400

400

8,5/4,9

11,1/6,4

14,8/8,5

14,8/8,5

11,3

15

15

20,5

32,0

39,0

27,0

18,0

24

NRB2 50X120 B

NRB2 50X120 A

NRB2 50X160 C

NRB2 50X160 B

NRB2 50X160 A

NRB2 50X200 C

NRB2 50X200 B

NRB2 50X200 A

NRB2 50X250 D

NRB2 50X250 C

NRB2 50X250 B

12,5 9,2

20 15

30 22

52,5

PA020200 400 52,0NRB2 50X250 A 40 30

17,5

21,5

25,2

27

32,5

36,5

46,5

57

77

450

27

52

70

88

94,5

17

21

24,9

26,5

32

36

45

56,5

76,5

500

30

51,5

69,5

87,5

94

15,5

20

24

25,5

31

35

43

55

75

600

42

49,5

67,5

86

93

13,5

18,6

23

23,5

29,5

34

40

53

72,5

700

48

46,5

65

84

91,5

16,5

21,5

21

27,5

32,5

36

50

69,5

800

54

43,5

61,5

82

89,5

19,5

25,5

31

31,5

46,5

66

900

60

39,5

57,5

78,5

86,5

17,5

22

29

43

61,5

1000

66

35

74,5

83,5

26

55,5

1100

72

69

80

1200

78

75,5

1300

70

51

104

NRB2 50

PUMP PERFORMANCE

NRB2 50X120 A

NRB2 50X120 B

NRB2 50X120 C

NRB2 50X160 A

NRB2 50X160 B

NRB2 50X160 C

NRB2 50X200 A

NRB2 50X200 B

NRB2 50X200 C

NRB2 50X250 A

NRB2 50X250 B

NRB2 50X250 C

NRB2 50X250 D

a f h2 b1 b2 l1 l2 l3 h h3 xa

TABLE OF SIZES AND WEIGHTS

ModelDimension mm.

WeightMotor DNm DNa

PN16 PN16Lm yType

112 M2

100 L2

90 L2

112 MC2

112 MB2

132 MC2

132 MB2

180 M2

112 MC2

200 LA2

160 L2

386

369

327

386

386

386

498

386

670

498

775

645

22

22

16

22

22

22

24

22

28

24

28

24

100

100

100

100

100

100

100

100

100

100

100

100

360

360

360

360

360

360

360

360

360

360

360

360

160

160

160

180

180

180

200

200

225

200

225

225

240

240

240

280

280

280

280

280

400

280

400

350

170

170

170

210

210

210

210

210

330

210

330

280

850

850

850

950

950

950

950

950

1120

950

1320

1120

800

800

800

900

900

900

900

900

1070

900

1270

1070

25

25

25

25

25

25

25

25

25

25

25

25

217

217

217

255

255

255

255

255

290

255

310

280

85

85

85

95

95

95

95

95

110

95

110

100

100

100

100

100

100

100

100

100

100

100

100

100

90

80

74

108

105

105

134

113

316

129

394

283

112 M2

132 MD2 498 24 100 360 225 350 280 950 900 25 280 100 100 185

65

65

65

65

65

65

65

65

65

65

65

65

65

50

50

50

50

50

50

50

50

50

50

50

50

50

36

Page 103: Electric Pumps Catalogue

MODELCODE

NominalPower

kWHP

Amp.3 X 400 V

QL/1'

m3/h

VOLTAGE( V )

NRB2 65X120 CPA021150

PA021160

PA021170

PA021180

PA020660

PA020990

PA020140

PA020930

PA020031

PA020100

PA020980

PA020310

NRB2 65X120 B

NRB2 65X120 A

NRB2 65X160 C

NRB2 65X160 B

NRB2 65X160 A

NRB2 65X200 C

NRB2 65X200 B

NRB2 65X200 ANRB2 65X250 C

NRB2 65X250 B

NRB2 65X250 A

5,5 4

7,5 5,5

10 7,5

12,5 9,2

15 11

25 18,5

40 30

50 37

Dis

char

ge h

ead

in m

eter

s

NR

B 2

230/400

400

400

400

400

400

400

400

400

400

400

400

14,8/8,5

11,3

15

18

20,5

27,0

32,0

39,0

52,0

52,0

65,0

78,0

18

21,4

23,8

600

42

20 15

30 22

40 30

60 45

17,5

21,1

23,6

30,8

700

48

33,8

40,8

17,2

20,5

23,4

30

800

54

33

40

51

57,5

62

72

82,5

92,5

16,6

20,3

23

29,5

900

60

32,5

39,5

50,6

57

61,7

71,5

82

92

15,8

19,8

22,6

28,5

1000

66

32

39

50,4

56,6

61,5

71

81,5

91,5

15

19,2

22

27,5

1100

72

31,5

38,5

50,2

56,5

61,3

70

80,5

91

14

18,4

21,5

26,5

1200

78

30,5

38

50,1

56,3

61,1

68,5

79,5

90

12,6

17,5

20,7

25,5

1300

84

29,5

37,5

49,7

56

61

67

78,5

89

16,4

20

24

1400

90

28,5

36,5

48,6

55,5

60,5

65

77

88

19

25,5

1500

96

27

35,5

47,5

54,5

60

63,3

75,5

87

17,5

21

1600

108

25,5

34,5

46

53,5

59

61,2

70

86

1800

120

22,5

32

43

50,5

57,5

57

70

82

2000

135

29

39

47,5

55

65,5

78

2250

42,5

50

59,5

72,5

NRB2 65

105

PUMP PERFORMANCE

NRB2 65X120 A

NRB2 65X120 B

NRB2 65X120 C

NRB2 65X160 A

NRB2 65X160 B

NRB2 65X160 C

NRB2 65X200 A

NRB2 65X200 B

NRB2 65X200 C

NRB2 65X250 A

NRB2 65X250 B

NRB2 65X250 C

a f h2 b1 b2 l1 l2 l3 h h3 xa

TABLE OF SIZES AND WEIGHTS

ModelDimension mm.

WeightMotor DNm DNa

PN16 PN16Lm yType

112 MC2

112 MB2

112 M2

132 MD2

132 MC2

200 LA2

180 M2

200 LB2

160 L2

225 M2

200 LA2

386

386

386

498

498

498

775

645

775

670

815

775

22

22

22

24

24

24

28

24

28

28

33

28

80

80

80

80

80

80

80

80

80

80

80

80

65

65

65

65

65

65

65

65

65

65

65

65

100

100

100

100

100

100

100

100

100

100

100

100

360

360

360

360

360

360

360

360

470

360

470

470

180

180

180

200

200

200

225

225

250

225

250

250

280

280

280

280

280

280

400

350

400

400

580

400

210

210

210

210

210

210

330

280

330

330

540

330

950

950

950

950

950

950

1320

1120

1320

1120

1400

1320

900

900

900

900

900

900

1270

1070

1270

1070

1300

1270

25

25

25

25

25

25

25

25

25

25

50

25

255

255

255

255

255

255

310

280

310

290

355

310

95

95

95

95

95

95

110

100

110

110

20

110

100

100

100

100

100

100

100

100

125

100

100

125

106

106

106

142

134

129

388

277

419

310

543

399

132 MB2

36

Page 104: Electric Pumps Catalogue

MODELCODE

NominalPower

kWHP

Amp.3 X 400 V

QL/1'

m3/h

VOLTAGE( V )

NRB2 80X160 CPA021190

PA021200

PA020925

PA020935

PA020945

PA020955

PA020860

PA020965

PA020932

PA020934

15 11

20 15

25 18,5

30 22

40 30

50 37

50 37

75 55

Dis

char

ge h

ead

in m

eter

s

400

400

400

400

400

400

400

400

400

400

20,5

27,0

32,0

39,0

52,0

65,0

65,0

95,0

78,0

NRB2 80X160 B

NRB2 80X160 A

NRB2 80X200 C

NRB2 80X200 B

NRB2 80X200 A

NRB2 80X250 D

NRB2 80X250 C

NRB2 80X250 B

NRB2 80X250 A

60 45

100 75

28,5

33,6

38

44,6

53

58,5

1200

72

28

33,5

37,8

44,5

52,5

58

1300

78

27,5

33,4

37,6

44

52

57,5

1400

84

27

33

37,2

43,5

51,5

56,5

68

84

1500

90

74,6

26,5

32,5

36,8

43

51

56

67,5

83,5

1600

96

74,5

26

32

36,5

42

50,5

55,5

66,5

83

1800

108

73,5

24,8

31

35,5

40,5

49,5

54

65

82

2000

120

72,5

22,5

29,5

34,5

38,5

48

52,5

62,5

81

2250

135

70,5

20

28

33

36,5

46

50,5

60

78,5

2500

150

68

24,5

31,5

33,5

44

48,5

56

76

2750

165

65

23

29

31

41,5

46

51

73,5

3000

180

61,5

27

38,5

43,5

70

3250

195

57,5

66

3500

210

53

4000

240

90,5 90 89,5 89 87,5 86 84 81,5 78,5 75 66

57

106

NRB2 80

PUMP PERFORMANCE

NRB2 80X160 A

NRB2 80X160 B

NRB2 80X160 C

NRB2 80X200 A

NRB2 80X200 B

NRB2 80X200 C

NRB2 80X250 A

NRB2 80X250 B

NRB2 80X250 C

NRB2 80X250 D

a f h2 b1 b2 l1 l2 l3 h h3 xa

TABLE OF SIZES AND WEIGHTS

ModelDimension mm.

WeightMotor DNm DNa

PN16 PN16Lm yType

160 L2

132 MD2

132 MC2

200 LB2

200 LA2

280 S2

250 M2

225 M2

200 LB2

645

498

498

775

775

670

1000

815

930

775

24

24

24

28

28

28

33

33

33

28

100

100

100

100

100

100

100

100

100

100

80

80

80

80

80

80

80

80

80

80

125

125

125

125

125

125

125

125

125

125

360

360

360

470

470

470

470

470

470

470

225

225

225

250

250

250

280

280

280

280

350

350

350

400

400

400

660

580

660

330

280

280

280

330

330

330

620

540

620

330

1120

950

950

1320

1320

1320

1600

1400

1600

1320

1070

900

900

1270

1270

1270

1500

1300

1500

1320

25

25

25

25

25

25

50

50

50

25

280

280

280

310

310

290

415

355

390

310

100

100

100

110

110

110

20

20

20

110

100

100

100

100

100

100

100

100

100

125

278

180

172

424

404

341

833

553

683

429

180 M2

127,0

Page 105: Electric Pumps Catalogue

MODELCODE

NominalPower

kWHP

Amp.3 X 400 V

QL/1'

m3/h

VOLTAGE( V )

NRB2 100X200 DPA021210

PA021220

PA021230

PA020770

PA021240

PA020740

PA020950

PA020960

NRB2 100X200 C

NRB2 100X200 B

NRB2 100X200 A

NRB2 100X250 D

NRB2 100X250 C

NRB2 100X250 B

NRB2 100X250 A

30 22

40 30

50 37

60 45

60 45

100 75

Dis

char

ge h

ead

in m

eter

s

NR

B 2

400

400

400

400

400

400

400

400

39,0

52,0

65,0

78,0

78,0

95,0

127,0

152,0

75 55

125 90

37,5

45

50,5

55,5

2000

120

66,5

73

NRB2 100

107

PUMP PERFORMANCE

83

89,5

36,5

44,5

50

55

2250

135

66

72,5

82,8

89,3

35

43,5

49,5

54,5

2500

150

65

72

82,5

89

33,5

42,5

48,5

54

2750

165

63,5

71

82

88,2

31,5

41

47,5

53

3000

180

61,5

69,5

81

87,5

29

39,5

46,5

52

3250

195

58,5

68

79,5

86,5

27

37,5

45

51

3500

210

56

66

78

85,5

20,5

33

41,5

48

4000

240

49,5

61

74

82,5

27

36,5

43,5

4500

270

53,5

70

78

31

38

5000

300

63

73

5500

330

55

65

NRB2 100X200 A

NRB2 100X200 B

NRB2 100X200 C

NRB2 100X200 D

NRB2 100X250 A

NRB2 100X250 B

NRB2 100X250 C

NRB2 100X250 D

a f h2 b1 b2 l1 l2 l3 h h3 xa

TABLE OF SIZES AND WEIGHTS

ModelDimension mm.

WeightMotor DNm DNa

PN16 PN16Lm yType

225 M2

200 LB2

200 LA2

180 M2

280 M2

250 M2

225 M2

815

775

775

670

1050

1000

930

815

33

28

28

28

33

33

33

33

125

125

125

125

125

125

125

125

100

100

100

100

100

100

100

100

125

125

125

125

140

140

140

140

470

470

470

470

470

470

470

470

280

280

280

280

280

280

280

280

580

400

400

400

660

660

660

580

540

330

330

330

620

620

620

540

1400

1320

1320

1320

1600

1600

1600

1400

1300

1270

1270

1270

1500

1500

1500

1300

50

25

25

25

50

50

50

50

355

310

310

310

415

415

390

355

20

110

110

110

20

20

20

20

100

125

125

125

100

100

100

100

550

426

406

365

883

837

695

557

280 S2

Page 106: Electric Pumps Catalogue

H(m)

4 POLES

NRB4

108

Performance range

32x120

32x160

32x200

32x250

65x120

65x160

65x200

65x250

40x120 50x120

50x160

50x200

50x250

40x160

40x200

40x250

80x160

80x200

80x250

100x200

100x250

10 1003 20 2005 50

2

3

6

4

5

8

10

15

20

25

30

Q:(m3/h)

Page 107: Electric Pumps Catalogue

MODELCODE

NominalPower

kWHP

Amp.3 X 400 V

QL/1'

m3/h

VOLTAGE( V )

NRB4 32X120 CPA021950

PA021960

PA021970

PA021980

PA021990

PA022000

PA022010

PA022020

PA021250

PA021260

PA021270

PA021280

NRB4 32X120 B

NRB4 32X120 A

NRB4 32X160 C

NRB4 32X160 B

NRB4 32X160 A

NRB4 32X200 C

NRB4 32X200 B

NRB4 32X200 ANRB4 32X250 C

NRB4 32X250 B

NRB4 32X250 A

0,33 0,25

0,33 0,25

0,33 0,25

0,33 0,25

0,5 0,37

0,75 0,55

1,5 1,1

2 1,5

Dis

char

ge h

ead

in m

eter

s

NR

B 4

230/400

230/400

230/400

230/400

230/400

230/400

230/400

230/400

230/400

230/400

230/400

230/400

1,46 - 0,85

1,46 - 0,85

1,46 - 0,85

1,46 - 0,85

2 - 1,15

2 - 1,15

2 - 1,15

3,3 - 1,9

4,7 - 2,7

4,7 - 2,7

6,1 - 3,5

6,1 - 3,5

4,5

5,4

6,2

50

3

0,5 0,37

1 0,75

1,5 1,1

2 1,5

NRB4 32

109

PUMP PERFORMANCE

7,8

8,6

9,4

4,3

5,2

6

75

4,5

7,6

7,9

9,2

11,2

13,2

14,5

18

20,4

22

3,8

4,8

5,8

100

6

7,2

8

8,9

10,8

13

14,2

17,5

20

21,6

3

4,2

5,3

125

7,5

6,5

7,5

8,4

10,2

12,5

13,8

16,8

19,5

21,2

2,1

3,4

4,6

150

9

5,6

6,7

7,7

9,5

11,8

13,3

15,7

18,6

20,4

2,5

3,8

175

11

4,6

5,7

6,8

8,6

11,1

12,6

14,2

17,4

19,4

2,9

200

12

4,6

5,8

7,5

10,3

11,8

12,7

16

18

225

14

6,5

9,2

10,9

10,8

14,4

16,5

250

15

8,2

10

12,5

14,8

NRB4 32X120 A

NRB4 32X120 B

NRB4 32X120 C

NRB4 32X160 A

NRB4 32X160 B

NRB4 32X160 C

NRB4 32X200 A

NRB4 32X200 B

NRB4 32X200 C

NRB4 32X250 A

NRB4 32X250 B

NRB4 32X250 C

a f h2 b1 b2 l1 l2 l3 h h3 xa

TABLE OF SIZES AND WEIGHTS

ModelDimension mm.

WeightMotor DNm DNa

PN16 PN16Lm yType

71 A4

71 A4

71 A4

71 B4

71 B4

90 S4

80 B4

90 L4

80 A4

90 L4

90 S4

244

244

244

244

244

244

302

280

327

280

327

302

16

16

16

16

16

16

16

16

16

16

16

16

32

32

32

32

32

32

32

32

32

32

32

32

50

50

50

50

50

50

50

50

50

50

50

50

80

80

80

80

80

80

80

80

100

80

100

100

360

360

360

360

360

360

360

360

360

360

360

360

140

140

140

160

160

160

180

180

225

180

225

225

240

240

240

240

240

240

240

240

350

240

350

350

170

170

170

170

170

170

170

170

280

170

280

280

850

850

850

850

850

850

850

850

950

850

950

950

800

800

800

800

800

800

800

800

900

800

900

900

25

25

25

25

25

25

25

25

25

25

25

25

197

197

197

217

217

217

245

245

280

245

280

280

85

85

85

85

85

85

85

85

100

85

100

100

100

100

100

100

100

100

100

100

100

100

100

100

59

59

59

66

66

66

77

73

115

75

115

114

71 A4

Page 108: Electric Pumps Catalogue

MODELCODE

NominalPower

kWHP

Amp.3 X 400 V

QL/1'

m3/h

VOLTAGE( V )

NRB4 40X120 CPA022030

PA022040

PA022050

PA022060

PA022070

PA022080

PA022090

PA021290

PA021300

PA021310

PA021320

PA021330

0,33

0,5

0,5

0,5

0,75

0,75

1

1,5

3

Dis

char

ge h

ead

in m

eter

s

230/400

230/400

230/400

230/400

230/400

230/400

230/400

230/400

230/400

230/400

230/400

230/400

1,46 - 0,85

2 - 1,15

2 - 1,15

2 - 1,15

2 - 1,15

2 - 1,15

3,3 - 1,9

4,7 - 2,7

8,5 - 4,9

8,5 - 4,9

6,1 - 3,5

4,7 - 2,7

NRB4 40X120 B

NRB4 40X120 A

NRB4 40X160 C

NRB4 40X160 B

NRB4 40X160 A

NRB4 40X200 C

NRB4 40X200 B

NRB4 40X200 A

NRB4 40X250 C

NRB4 40X250 B

NRB4 40X250 A

1,5

2

3

110

NRB4 40

PUMP PERFORMANCE

4,6

5,4

6,3

7,3

8

8,8

100

6

4,5

5,3

6,2

7

7,8

8,6

11

14

19,7

125

7,5

12,8

17,2

22,3

4,3

5,2

6,1

6,7

7,5

8,4

10,5

13,8

19,5

150

9

12,5

17

22

4

5

6

6,4

7,2

8,1

10

13,5

19,2

175

10,5

12,1

16,6

21,7

3,7

4,8

5,8

6

6,8

7,7

9,4

13

18,6

200

12

11,6

16

21,4

3,3

4,5

5,5

5,5

6,4

7,3

8,5

12,4

18

225

13,5

11

15,3

21

2,5

4,1

5,2

4,9

5,9

6,8

7,6

11,8

17,5

250

15

10,2

14,5

20,3

3,5

4,9

4,3

5,3

6,3

6,6

11

16,8

275

16,5

9,3

14

19,6

4,4

4,7

5,8

5,4

10,2

16

300

18

8,4

13

19

8,3

14

350

21

6,2

10,6

17,5

11,5

400

24

15,5

450

27

13

NRB4 40X120 A

NRB4 40X120 B

NRB4 40X120 C

NRB4 40X160 A

NRB4 40X160 B

NRB4 40X160 C

NRB4 40X200 A

NRB4 40X200 B

NRB4 40X200 C

NRB4 40X250 A

NRB4 40X250 B

NRB4 40X250 C

a f h2 b1 b2 l1 l2 l3 h h3 xa

TABLE OF SIZES AND WEIGHTS

ModelDimension mm.

WeightMotor DNm DNa

PN16 PN16Lm yType

0,25

0,37

0,37

0,37

0,55

0,55

0,75

1,1

2,2

1,1

1,5

2,2

71 B4

71 B4

71 A4

80 A4

80 A4

90 S4

90 S4

100 LA4

80 B4

100 LA4

90 L4

244

244

244

280

280

244

302

280

369

302

369

327

16

16

16

16

16

16

16

16

22

16

22

16

40

40

40

40

40

40

40

40

40

40

40

40

65

65

65

65

65

65

65

65

65

65

65

65

80

80

80

80

80

80

100

100

100

100

100

100

360

360

360

360

360

360

360

360

360

360

360

360

140

140

140

160

160

160

180

180

225

180

225

225

240

240

240

240

240

240

280

280

350

280

350

350

170

170

170

170

170

170

210

210

280

210

280

280

850

850

850

850

850

850

950

950

950

950

950

950

800

800

800

800

800

800

900

900

900

900

900

900

25

25

25

25

25

25

25

25

25

25

25

25

197

197

197

217

217

217

255

255

280

255

280

280

85

85

85

85

85

85

95

95

100

95

100

100

100

100

100

100

100

100

100

100

100

100

100

100

62

62

61

69

69

67

91

89

131

91

131

124

71 B4

Page 109: Electric Pumps Catalogue

230/400

230/400

230/400

230/400

230/400

230/400

230/400

230/400

230/400

230/400

230/400

230/400

MODELCODE

NominalPower

kWHP

Amp.3 X 400 V

QL/1'

m3/h

VOLTAGE( V )

NRB4 50X120 CPA022100

PA022110

PA022120

PA022130

PA022140

PA021340

PA021350

PA021360

PA021370

PA021380

PA021390

PA021400

NRB4 50X120 B

NRB4 50X120 A

NRB4 50X160 C

NRB4 50X160 B

NRB4 50X160 A

NRB4 50X200 C

NRB4 50X200 B

NRB4 50X200 ANRB4 50X250 D

NRB4 50X250 C

NRB4 50X250 B

0,33 0,25

0,5 0,37

0,75 0,55

0,75 0,55

1,0 0,75

1,5 1,1

2,0 1,5

3,0 2,2

Dis

char

ge h

ead

in m

eter

s

NR

B 4

1,46 - 0,85

2 - 1,15

2 - 1,15

2 - 1,15

3,3 - 1,9

4,7 - 2,7

4,7 - 2,7

4,7 - 2,7

6,1 - 3,5

8,5 - 4,9

8,5 - 4,9

11,1 - 6,4

1,5 1,1

1,5 1,1

3,0 2,2

4,0 3,0

NRB4 50

111

PUMP PERFORMANCE

PA021410 NRB4 50X250 A 11,1 - 6,44,0 3,0

4,4

5,3

6,3

150

9

4,2

5,1

6,1

6,8

200

12

8

9

11,6

13

14,3

16,8

18,4

21

22,5

4

4,9

5,9

6,6

250

15

7,8

8,8

11,2

12,6

14,1

16,4

18

20,6

22,3

3,6

4,7

5,7

6,3

300

18

7,6

8,6

10,5

12,2

13,7

15,8

17,6

20,2

22

3,2

4,4

5,5

5,9

350

21

7,4

8,4

9,6

11,3

13,1

15,1

17

19,7

21,5

2,6

4

5,2

5,3

400

24

7

8,2

8,6

10,4

12,3

14,2

16,2

19,1

20,9

3,5

4,8

4,4

450

27

6,4

7,7

7,4

9,4

11,4

13,2

15,2

18,3

20,2

4,4

500

30

5,6

7,1

6,2

8,2

10,2

11,9

14,2

17,4

19,4

550

33

6,4

7

9

10,5

12,8

16,4

18,5

600

36

15,2

17,4

700

42

14,7

11,5

7,8

a f h2 b1 b2 l1 l2 l3 h h3 xa

TABLE OF SIZES AND WEIGHTS

ModelDimension mm.

WeightMotor DNm DNa

PN16 PN16Lm yType

NRB4 50X120 A

NRB4 50X120 B

NRB4 50X120 C

NRB4 50X160 A

NRB4 50X160 B

NRB4 50X160 C

NRB4 50X200 A

NRB4 50X200 B

NRB4 50X200 C

NRB4 50X250 A

NRB4 50X250 B

NRB4 50X250 C

NRB4 50X250 D

230/400

80 A4

71 B4

71 A4

90 S4

80 B4

90 L4

90 S4

100 LB4

90 S4

100 LB4

100 LA4

280

244

244

302

280

280

327

302

369

302

369

369

16

16

16

16

16

16

16

16

22

16

22

22

50

50

50

50

50

50

50

50

50

50

50

50

100

100

100

100

100

100

100

100

100

100

100

100

360

360

360

360

360

360

360

360

360

360

360

360

160

160

160

180

180

180

200

200

225

200

225

225

240

240

240

280

280

280

280

280

350

280

350

350

170

170

170

210

210

210

210

210

280

210

280

280

850

850

850

950

950

950

950

950

950

950

950

950

800

800

800

900

900

900

900

900

900

900

900

900

25

25

25

25

25

25

25

25

25

25

25

25

217

217

217

255

255

255

255

255

280

255

280

280

85

85

85

95

95

95

95

95

100

95

100

100

100

100

100

100

100

100

100

100

100

100

100

100

68

66

65

87

85

83

93

92

135

92

135

132

80 A4

100 LA4 369 22 50 100 360 225 350 280 950 900 25 280 100 100 132

65

65

65

65

65

65

65

65

65

65

65

65

65

Page 110: Electric Pumps Catalogue

MODELCODE

NominalPower

kWHP

Amp.3 X 400 V

QL/1'

m3/h

VOLTAGE( V )

NRB4 65X120 CPA022150

PA022160

PA022170

PA021420

PA021430

PA021440

PA021450

PA021460

PA021470

PA021480

PA021490

PA021500

0,75

0,75

1,0

1,5

1,5

2,0

3,0

4,0

5,5

Dis

char

ge h

ead

in m

eter

s

2 - 1,15

2 - 1,15

3,3 - 1,9

4,7 - 2,7

4,7 - 2,7

6,1 - 3,5

8,5 - 4,9

11,1 - 6,4

14,8 - 8,5

11,3

11,1 - 6,4

11,1 - 6,4

NRB4 65X120 B

NRB4 65X120 A

NRB4 65X160 C

NRB4 65X160 B

NRB4 65X160 A

NRB4 65X200 C

NRB4 65X200 B

NRB4 65X200 A

NRB4 65X250 C

NRB4 65X250 B

NRB4 65X250 A

4,0

4,0

7,5

112

NRB4 65

PUMP PERFORMANCE

250

15

300

18

350

21

400

24

450

27

500

30

550

33

600

36

700

42

800

48

900

54

1000

60

1100

66

1200

72

1400

84

NRB4 65X120 A

NRB4 65X120 B

NRB4 65X120 C

NRB4 65X160 A

NRB4 65X160 B

NRB4 65X160 C

NRB4 65X200 A

NRB4 65X200 B

NRB4 65X200 C

NRB4 65X250 A

NRB4 65X250 B

NRB4 65X250 C

230/400

230/400

230/400

230/400

230/400

230/400

230/400

230/400

230/400

400

230/400

230/400

a f h2 b1 b2 l1 l2 l3 h h3 xa

TABLE OF SIZES AND WEIGHTS

ModelDimension mm.

WeightMotor DNm DNa

PN16 PN16Lm yType

0,55

0,55

0,75

1,1

1,1

1,5

2,2

3,0

4,0

3,0

3,0

5,5

4,2

5

4

4,8

5,6

7,7

8,5

10,2

3,9

4,7

5,5

7,6

8,4

10,1

3,8

4,6

5,4

7,5

8,3

10

12,3

15

13,7

3,7

4,5

5,3

7,3

8,2

9,9

12,2

14,9

13,6

3,5

4,4

5,2

7,1

8

9,8

12,1

14,8

20

13,5

17,2

23

3,3

4,3

5,1

6,8

7,8

9,6

12

14,7

19,7

13,4

17

22,8

3

4,2

4,9

6,5

7,6

9,4

11,9

14,6

19,4

13,3

16,6

22,6

3,7

4,5

5,7

6,9

9

11,5

14,4

18,8

13,1

15,7

22,1

4

4,7

5,9

8,4

10,8

14,1

18

12,6

14,6

21,5

4,9

7,5

10

13,5

16,8

11,9

13,2

20,7

6,5

9

12,8

15,6

11

1,6

19,7

12

14,3

10

18,6

11

12,5

17,4 14

80 B4

80 A4

80 A4

90 L4

90 S4

100 LB4

100 LB4

112 M4

100 LA4

112 MC4

100 LB4

280

280

280

327

302

302

369

369

386

369

386

369

16

16

16

16

16

16

22

22

22

22

22

22

65

65

65

65

65

65

65

65

65

65

65

65

80

80

80

80

80

80

80

80

80

80

80

80

100

100

100

100

100

100

100

100

100

100

100

100

360

360

360

360

360

360

360

360

470

360

470

470

180

180

180

200

200

200

225

225

250

225

250

250

280

280

280

280

280

280

350

350

400

350

400

400

210

210

210

210

210

210

280

280

330

280

330

330

950

950

950

950

950

950

950

950

1120

950

1120

1120

900

900

900

900

900

900

900

900

1070

900

1070

1070

25

25

25

25

25

25

25

25

25

25

25

25

255

255

255

255

255

255

280

280

310

280

310

310

95

95

95

95

95

95

100

100

110

100

110

110

100

100

100

100

100

100

100

100

125

100

125

125

86

84

84

93

92

92

129

126

181

129

181

172

90 S4

Page 111: Electric Pumps Catalogue

MODELCODE

NominalPower

kWHP

Amp.3 X 400 V

QL/1'

m3/h

VOLTAGE( V )

NRB4 80X160 CPA021510

PA021520

PA021530

PA021540

PA021550

PA021560

PA021570

PA021580

PA021590

PA021600

NRB4 80X160 B

NRB4 80X160 A

NRB4 80X200 C

NRB4 80X200 B

NRB4 80X200 A

NRB4 80X250 D

NRB4 80X250 C

NRB4 80X250 B

NRB4 80X250 A

2 1,5

3 2,2

3 2,2

4 2,2

5,5 3

7,5 5,5

10 7,5

Dis

char

ge h

ead

in m

eter

s

NR

B 4

6,1 - 3,5

8,5 - 4,9

8,5 - 4,9

8,5 - 4,9

11,1 - 6,4

14,8 - 8,5

11,3

11,3

15

15

5,5 4

7,5 5,5

10 7,5

NRB4 80

113

PUMP PERFORMANCE

7,1

8,5

9,6

600

36

6,9

8,3

9,4

700

42

10,4

12,5

14,2

16,3

17,9

20,5

22,2

6,6

8,1

9,2

800

48

10

12,3

14

16

17,7

20,3

22

6,3

7,9

9

900

54

9,8

12,1

13,8

15,7

17,4

20

21,7

6

7,6

8,8

1000

60

9,6

11,8

13,5

15,4

17

19,7

21,5

5,7

7,3

8,5

1100

66

9

11,4

13,1

14,9

16,7

19,4

21,1

5,2

6,9

8,2

1200

72

8,6

11

12,7

14,4

16,2

19

20,8

4,8

6,5

7,9

1300

78

8

10,6

12,2

13,7

15,7

18,6

20,4

6,1

7,5

1400

84

7,2

10

11,7

13

15

18,1

20

5,6

7,1

1500

90

6,5

9,4

11,2

12,3

14,4

17,6

19,5

6,6

1600

96

8,8

10,6

11,5

13,7

17

19

1800

108

7,2

9,2

11,9

15,6

17,6

2000

120

7,6

13,9

16,2

2250

135

14

NRB4 80X160 A

NRB4 80X160 B

NRB4 80X160 C

NRB4 80X200 A

NRB4 80X200 B

NRB4 80X200 C

NRB4 80X250 A

NRB4 80X250 B

NRB4 80X250 C

NRB4 80X250 D

230/400

230/400

230/400

230/400

230/400

230/400

400

400

400

400

a f h2 b1 b2 l1 l2 l3 h h3 xa

TABLE OF SIZES AND WEIGHTS

ModelDimension mm.

WeightMotor DNm DNa

PN16 PN16Lm yType

100 LA4

100 LA4

90 L4

112 M4

112 M4

132 MA4

132 MA4

112 MC4

112 MC4

369

369

327

386

386

369

498

386

498

386

22

22

16

22

22

22

24

22

24

22

80

80

80

80

80

80

80

80

80

80

100

100

100

100

100

100

100

100

100

100

125

125

125

125

125

125

125

125

125

125

360

360

360

470

470

470

470

470

470

470

225

225

225

250

250

250

280

280

280

280

350

350

350

350

350

350

400

400

400

400

280

280

280

280

280

280

330

330

330

330

950

950

950

1120

1120

1120

1120

1120

1120

1120

900

900

900

1070

1070

1070

1070

1070

1070

1070

25

25

25

25

25

25

25

25

25

25

280

280

280

280

280

280

310

310

310

310

100

100

100

100

100

100

110

110

110

110

100

100

100

100

100

100

125

125

125

125

127

127

120

166

166

156

213

191

213

191

100 LB4

Page 112: Electric Pumps Catalogue

MODELCODE

NominalPower

kWHP

Amp.3 X 400 V

QL/1'

m3/h

VOLTAGE( V )

NRB4 100X200 DPA021610

PA021620

PA021630

PA021640

PA021680

PA021660

PA021670

PA021650

4

5,5

7,5

7,5

7,5

10

12,5

Dis

char

ge h

ead

in m

eter

s

230/400

230/400

400

400

400

400

400

400

11,1 - 6,4

14,8 - 8,5

11,3

11,3

11,3

15

18

18

NRB4 100X200 C

NRB4 100X200 B

NRB4 100X200 A

NRB4 100X250 D

NRB4 100X250 C

NRB4 100X250 B

NRB4 100X250 A 12,5

114

NRB4 100

PUMP PERFORMANCE

900

54

1000

60

1100

66

1200

72

1300

78

1400

84

1500

90

1600

96

1800

108

2000

120

2250

135

2500

150

2750

165

3000

180

NRB4 100X200 A

NRB4 100X200 B

NRB4 100X200 C

NRB4 100X200 D

NRB4 100X250 A

NRB4 100X250 B

NRB4 100X250 C

NRB4 100X250 D

a f h2 b1 b2 l1 l2 l3 h h3 xa

TABLE OF SIZES AND WEIGHTS

ModelDimension mm.

WeightMotor DNm DNa

PN16 PN16Lm yType

3

4

5,5

5,5

5,5

7,5

9,2

9,2

9,8

11,8

9,6

11,6

13,1

14,3

16,4

18

9,4

11,4

12,9

14,2

16,2

17,8

9,1

11,2

12,7

14

15,9

17,6

20,2

21,8

8,8

11

12,5

13,8

15,6

17,4

20

21,7

8,5

10,8

12,3

13,6

15,3

17,1

19,8

21,6

8,1

10,5

12

13,4

14,9

16,8

19,6

21,4

7,7

10,2

11,7

13,2

14,4

16,4

19,3

21,1

9,4

11,1

12,6

13,2

15,3

18,6

20,4

10,3

12

11,9

14,2

17,7

19,7

9,8

12,4

16,2

18,5

10,4

14,5

17 15

6,9 6

8,6 7,5

20,4

22

20,3

21,9

13,2

14,4

8,2

9,8 8,5

9,3

11

12,4

12,8

112 MC4

112 MC4

112 M4

100 LB4

132 MB4

132 MA4

112 MC4

386

386

386

369

498

498

498

386

22

22

22

22

24

24

24

22

100

100

100

100

100

100

100

100

125

125

125

125

125

125

125

125

125

125

125

125

140

140

140

140

470

470

470

470

470

470

470

470

280

280

280

280

280

280

280

280

400

400

400

400

400

400

400

400

330

330

330

330

330

330

330

330

1120

1120

1120

1120

1120

1120

1120

1120

1070

1070

1070

1070

1070

1070

1070

1070

25

25

25

25

25

25

25

25

310

310

310

310

335

335

335

335

110

110

110

110

110

110

110

110

125

125

125

125

125

125

125

125

188

188

188

179

227

227

225

203

132 MB4

Page 113: Electric Pumps Catalogue

BARESHAFT END-SUCTION CENTRIFUGAL PUMPS

NRI 65X120 CPA021840PA021850PA021860

PA021870

PA020380

PA020370

PA020141

PA020170

PA020030PA020970

PA020110

PA020300

NRI 65X120 BNRI 65X120 A

NRI 65X160 C

NRI 65X160 B

NRI 65X160 A

NRI 65X200 C

NRI 65X200 B

NRI 65X200 ANRI 65X250 C

NRI 65X250 B

NRI 65X250 A

NRI 50MODELCODE

NRI 50X120 CPA021790

PA021800

PA021810

PA021820

PA021830

PA020975

PA020240

PA020220

PA020080PA020890

PA020920

NRI 50X120 B

NRI 50X120 ANRI 50X160 CNRI 50X160 B

NRI 50X160 A

NRI 50X200 CNRI 50X200 BNRI 50X200 ANRI 50X250 D

NRI 50X250 CPA020250 NRI 50X250 B

NRI 65MODELCODE

PA020160 NRI 50X250 A

NRI 100X200 DPA021900PA021910PA021920

PA020760

PA021930

PA020730

PA020940

PA021940

NRI 100X200 CNRI 100X200 B

NRI 100X200 A

NRI 100X250 D

NRI 100X250 C

NRI 100X250 B

NRI 100X250 A

NRI 80MODELCODE

NRI 80X160 CPA021880

PA021890

PA020875

PA020885

PA020895

PA020905

PA020870

PA020910

PA020040PA020915

NRI 80X160 B

NRI 80X160 ANRI 80X200 CNRI 80X200 B

NRI 80X200 A

NRI 80X250 DNRI 80X250 CNRI 80X250 BNRI 80X250 A

NRI 100MODELCODE

NRI 40X120 CPA021740PA021750PA021760

PA021770

PA021780

PA020230

PA020360

PA020850

PA020690PA020061

PA020811

PA020985

NRI 40X120 BNRI 40X120 A

NRI 40X160 C

NRI 40X160 B

NRI 40X160 A

NRI 40X200 C

NRI 40X200 B

NRI 40X200 ANRI 40X250 C

NRI 40X250 B

NRI 40X250 A

NRI 32MODELCODE

NRI 32X120 CPA021690

PA021700

PA021710

PA021720

PA021730

PA020021

PA020710

PA020820

PA020320PA020700

PA020936

NRI 32X120 B

NRI 32X120 ANRI 32X160 CNRI 32X160 B

NRI 32X160 A

NRI 32X200 CNRI 32X200 BNRI 32X200 ANRI 32X250 C

NRI 32X250 BPA020335 NRI 32X250 A

NRI 40MODELCODE

NR

I

NRI

115

Page 114: Electric Pumps Catalogue

CMHORIZONTAL SINGLE-STAGE CENTRIFUGAL PUMPS

The CM series single impeller centrifugal pumps are silent and have a high hydraulicefficiency.

• HIGH RELIABILITY• STRONG AND RESISTANT• HIGH HYDRAULIC PERFORMANCE

116

Motor- Enclosed, externally ventilated- Level of protection IP 44- Class F insulation- Single phase power supply with capacitor permanently activated and thermal protection built into the motor winding- Three phase power supply with external protection provided by the user- Speed of rotation 2850 rpm- Suitable for continuous use

Applications- Pumping from wells for irrigation- Booster systems- Domestic autoclaves- Washing systems

Usage limitations- Type of liquid: non-abrasive clear or slightly cloudy water- Maximum liquid temperature 90°C (model CM 90/22 50°C)- Maximum recommended suction height 5 m with foot valve- Maximum operating pressure: 6 bar for models HP 0.5 - 0.75 8 bar for models HP 1 - 1.5 - 2

Component

Pump casing

Motor bracket

Motor shaft

O-ring

Material

EN GJL 200 (ex G20) Cast iron

EN GJL 200 (ex G20) Cast iron

X12 CrNiS 1809 (AISI 416) Stainless steel

DESIGN FEATURES

123 Impeller

57

NBR 70 shore10

Brass (CM 90/22 in technopolymer)

8 Counterface Ceramic

Mechanical seal Graphite

Page 115: Electric Pumps Catalogue

117 C

M

TABLE OF HYDRAULIC PERFORMANCE

CM

PUMP PERFORMANCE

TABLE OF SIZES AND WEIGHTS

ModelDimensions mm. Weight

A

82 CM 100/36

B C D E F H1 H2 DNA DNM kg

44 310 180 140 185 107 242 1" 1" 11

88 CM 110/44 45 350 194 155 200 100 252 1"1/4 1" 20,5

88 CM 130/51 45 350 220 180 225 115 286 1"1/4 1" 23

CM 90/22 75 43 267 150 110 160 82 202 1" 1" 6,5

CM 100/36 M CM 100/36 T

0,5 0,35 1 ~ 220÷240 V3 ~ 230÷400 V 20 18 13

CM 110/44 M CM 110/44 T

1,5 1,1

CM 130/51 M CM 130/51 T

2 1,5 1 ~ 230 V3 ~ 230÷400 V

33 31 26 22

40 39 36 34

N418B130 N418B140 N4187090 N4187100 N4187110 N4187120

1 0,75

2,6 1,9

3,1 2,3 46 45 42 40 38

1 ~ 230 V3 ~ 230÷400 V

1 ~ 220÷240 V3 ~ 230÷400 V1 0,75 1,7 1,25

CM 90/22 M* CM 90/22 T*

N418B090 N418B100

3,62,4-1,4

10,87,8-4,5

9,25,7-3,3

5,53,8-2,2

12,5

40

35

20

22

35

41

47

* Technopolymer impeller

MODELCODE

AbsorbedPower

kWHPVOLTAGE Amp. µF. Q

L/1'

m3/h

10 80 100NominalPower

kWHP 0,6 4,8 6

120

7,2

30

1,8

50

3

Dis

char

ge h

ead

in m

eter

s 40

Hm

L / 1'm3/ h

Q

20

20 60 80 100

6

120 140 160

10

30

40

50

60

70

4 2 8

Page 116: Electric Pumps Catalogue

118

CB TWIN IMPELLER CENTRIFUGAL PUMPS

The CB twin impeller centrifugal electric pumps have two self balanced impellersto give very high efficiency. Particularly suitable for domestic and industrialapplications, booster sets etc.

• HIGH HYDRAULIC EFFICIENCY

Motor– Enclosed, externally ventilated– Level of protection: IP 44– Class insulation: F– Single phase power supply with capacitor pemanently activated and thermal protection built into the motor winding.– Three phase power supply with external protection provided by the user.

Applications– Booster systems– Small-scale irrigation– Non aggressive liquids transfer– Washing systems

Usage limitations– Type of liquid:non-abrasive clear or slightly cloudy water– Maximum liquid temperature: 40° C for models 0,55 - 0,75 Kw 90° C for models 1,1 - 4,0 Kw– Maximum recommended suction height: 5 m with foot– Maximum operating pressure: 6 bar for models 0,55 - 0,75 Kw 10 bar for models 1,1 - 4,0 Kw

Component

Pump casing

Motor bracket

Intermediate plate

Mechanical seal

Counterface

Material

EN GJL 200 (ex G20) Cast iron

Aluminium on models: Kw 0,55 - 1,00.Cast iron on the other models

DESIGN FEATURES

1

2

3 Impeller

4

5

Graphite6Ceramic7

Technopolymer on models: Kw 0,55 - 0,75.Brass on the other models

Motor shaftAISI 303 on models: Kw 1,1 - 1,5 - 2,2AISI 304 on models: Kw 3,0 - 4,0AISI 416 on models: Kw 0,55 - 0,75

Cast iron

Seal plate AISI 304 on models: Kw 0,55 - 0,75.Cast iron on the other models

8

O-ring NBR9

Page 117: Electric Pumps Catalogue

119 C

B

TABLE OF HYDRAULIC PERFORMANCE

CB

20

1,2

Hm

L / 1'

m3/ hQ

20

40

2,4

80

4,8

10

30

40

50

70

160

9,6

120

7,2

60

60 100 140

3,6 6,0 8,4

80

180

10,8

210/76

200

11,6

210

12,0

190/67

160/68120/65

110/55

90/4480/38

PUMP PERFORMANCE

0,75 0,55 1 ~ 220 V3 ~ 220 - 400

1,5 1,10

2 1,50 1 ~ 220 V3 ~ 220 - 400

CB 90/44 MCB 90/44 TCB 110/55 MCB 110/55 TCB 120/65 MCB 120/65 T

1 ~ 220 V3 ~ 220 - 400

1 ~ 220 V3 ~ 220 - 400

1 0,75

CB 80/38 MCB 80/38 T

53,4-2

10,87,2-4,1

8,65,6 -3,3

6,14,0-2,3

16

40

35

20

CB 160/68 T 3 2,20 3 ~ 220 - 400 8,8-5,1

N4189030N4189040N4189050N4189060N4189070N4189080

N4189010N4189020

N4189090

1,5

2,5

3,2

1,9

3,8

1,10

1,9

2,4

1,4

2,8N4189100N4189110

CB 190/67 TCB 210/76 T

0,75 0,55 161,4 1,0533,0 30,2 27,9 17,0

1 0,75 1,6 1,2 2039,5 37,0 35,2 27,0 21,0

1,5 1,10 2,4 1,8 3550,8 48,8 47,1 38,4 33,4 27,5

2 1,50 3,0 2,360,5 58,6 56,9 49,8 46,5 40,3 32,5

60,5 59,3 54,1 51,6 48,4 44,6 32,04 3,00 3 ~ 220 - 400 13,0-7,55,7 4,2 67,0 64,8 63,9 62,5 62,0 58,0 53,5 48,05 4,00 3 ~ 220 - 400 16,5-9,56,8 5,1 76,5 73,9 72,9 71,8 70,5 66,8 62,0 58,3 54,0

MODELCODE

AbsorbedPower

kWHPVOLTAGE Amp. µF. Q

L/1'

m3/h

20NominalPower

kWHP 1,2

40

2,4

50

3,0

80

4,8

90

5,4

100

6,0

110

6,6

140

8,4

170

9,6

190

10,80

210

12,00

TABLE OF SIZES AND WEIGHTS

ModelDimensions mm. Weight

A

58 CB 90/44

B C D E F H1 H2 DNA DNM kg

73 336 180 140 183 97 227 1" 1" 15,066 CB 110/55 86 394 195 155 209 110 265 1"1/4 1" 25,066 CB 120/65 86 410 195 155 209 110 265 1"1/4 1" 27,0

CB 80/38 58 73 336 180 140 183 97 227 1" 1" 13,5

CB 160/68 66 86 410 195 155 194 110 265 1"1/4 1" 27,0 CB 190/67 72 96 467 230 180 228 133 309 1"1/2 1"1/4 42,5 CB 210/76 72 96 467 230 180 228 133 309 1"1/2 1"1/4 46,3

Dis

char

ge h

ead

in m

eter

s

Page 118: Electric Pumps Catalogue

EPPERIPHERAL PUMPS

The EP series peripheral monobloc pumps are especially suitable where high headswith limited flow rates need to be developed.

• REDUCED DIMENSIONS• LOW CONSUMPTION

120

Motor- Enclosed, externally ventilated- Level of protection IP 44- Class F insulation- Single phase power supply with capacitor permanently activated and thermal protection built into the motor winding- Three phase power supply with external protection provided by the user- Speed of rotation 2850 rpm- Suitable for continuous use

Applications- Small-scale booster systems- Domestic autoclaves- Small-scale irrigation- Washing systems

Usage limitations- Type of liquid: clean water with no suspended solids or abrasive material- Maximum liquid temperature 70°C- Maximum recommended suction height 5m with foot valve- Maximum operating pressure 6.5 bar

Component

Pump casing

Motor bracket

Motor shaft

Mechanical seal

Counterface

O-ring

Material

EN GJL 200(ex G20) Cast iron

EN GJL 200(ex G20) Cast iron

X12 CrNiS 1809 (AISI 416) Stainless steel

Graphite

DESIGN FEATURES

Impeller

Ceramic

NBR 70 shore

Brass

Page 119: Electric Pumps Catalogue

121 E

P

TABLE OF HYDRAULIC PERFORMANCE

EP

PUMP PERFORMANCE

TABLE OF SIZES AND WEIGHTS

ModelDimensions mm. Weight

A B C D E DNA DNM kg

Hm

L / 1'm3/ h

Q

2

4

MODELCODE

AbsorbedPower

kWHPVOLTAGE Amp. µF. Q

L/1'

m3/h

5 30 40NominalPower

kWHP 0,3 1,8 2,4

50

3

10

0,6

20

1,2

20

1,2

20

10

0,6

30

1,8

40

2,4

50

3

60

3,6

70

4,2

80

4,8

10

30

40

50

60

70

60

3,6

EP2 M EP2 T

0,5 0,37 1 ~ 220÷240 V3 ~ 230÷400 V

2,21,6-0,9

36

59

29,3 18,4 8,8

55 46 37 28 19 EP4 M EP4 T

0,75 0,55 1 ~ 220÷240 V3 ~ 230÷400 V

53,8-2,2

N4162010F N4162020 N4164010 N4164020

0,75 0,55

1,6 1,2 9

8

16

295 90 112 156 150 1" 1" 11

EP2

EP4

260 85 100 145 135 1" 1" 6,8

Dis

char

gehe

adin

met

ers

Page 120: Electric Pumps Catalogue

SUBMERSIBLE PUMPS FOR OPEN AND DRILLED WELLS

Page 121: Electric Pumps Catalogue

PRATIKAMULTISTAGE CENTRIFUGALSUBMERSIBLE PUMPS FOR CLEAR WATER

The PRATIKA submersible pumps are portable and ready to use for installation intraditional wells, water deposits, collection tanks, clear watercourses, lakes etc.Equipped with Ø 32 hose adapter.Automatic version equipped with float switch.

124

Motor- Dry motor- Level of protection IP 68- Class F insulation- Single phase supply with capacitor permanently activated- Thermal protection built into the motor winding- Completely insulated cable connection chamber- Self-lubricating ball bearings- Speed of rotation 2850 rpm- Suitable for continuous use

Applications- Pumping of water from traditional wells- Domestic tank installations for boosting domestic drinking water systems- Small-scale automatic systems for garden irrigation- Surface irrigation

Usage limitations- Type of liquid: clean water with no suspended solids or abrasive material- Maximum liquid temperature 40° C- Maximum submersion under the water level 10 m

4

1

5

876

2

3

9

10

Component

Pump body

Suction grid

Power cable

Mechanical seal

Counterface

Lip seal

Material

X 5 CrNi 1810 (AISI 304) Stainless steel

X 5 CrNi 1810 (AISI 304) Stainless steel

Graphite

DESIGN FEATURES

123 Suction base

4

5

Ceramic

67

NBR 70 Rubber8

X 5 CrNi 1810 (AISI 304) Stainless steel

Shaft (hydraulic end)

15 m H07 RN-F With schuko plug

X 5 CrNi 1810 (AISI 304) Stainless steelwith ceramic facing at the points of seal wear

9

10

Impeller Technopolymer

Diffuser Technopolymer

Oil chamber forseal lubrication

Page 122: Electric Pumps Catalogue

125

PR

ATIK

A

TABLE OF HYDRAULIC PERFORMANCE

PRATIKA

PUMP PERFORMANCE

MODELCODE

AbsorbedPower

kWHPVOLTAGE Amp. µF. Q

L/1'

m3/h

0 80 100NominalPower

kWHP 4,8 60

20

1,2

40

2,4

60

3,6

PRATIKA

N3051000-B1 ~ 230 V1,6 1,21,1 0,8 39 31 2346 12 35 16

PRATIKA - AUT

N3051010-B

N˚Stadi

4

PRATIKA

10 7030 110

0,6 1,8 4,2 8,8

HmL / 1'm3/ h

Q

10

50

3

20

30

40

50

90

6

PRATIKA 406 9162 178 Ø 1,5 1" 1/450/60 260490182

TABLE OF SIZES AND WEIGHTS

Free boreStart level Stop levelMinimumdrainage level Model

Dimensions mm.

A

Weight

Ø C kgB DNMF* G*E*

* Start and stop level refers to the version equipped with floating switch The minimum drainage level refers to the manual version

D

Dischargehead

in meters

Page 123: Electric Pumps Catalogue

DOMINATOR 44” SUBMERSIBLE MULTISTAGE CENTRIFUGAL PUMPFOR CLEAN WATER

The DOMINATOR 4” submersible pumps are suitable for istallation in traditional wells,water deposits, collection tanks, clear watercourses, lakes etc.Supplied with 20m nylon suspension cord.

• HYDRAULIC SYSTEM RESISTANT TO THE SAND CORROSIVE ACTION.• INTEGRATED NO-RETURN VALVE• BUILT-IN CAPACITOR

Motor– Dry motor with stainless steel casing cooled by the pumped liquid.– Level of protection IP 68.– Class F insulation.– Single phase supply with capacitor permanently activated.– Thermal protection built into the motor winding.– Completely insulated cable connection chamber.– Self-lubricating ball bearings.– Speed of rotation 2850 rpm.– Suitable for continuous use.

Applications– Pumping of water from traditional wells.– Domestic tank installations for boosting domestic drinking water systems.– Small-scale automatic systems for garden irrigation.– Surface irrigation.

Usage limitations– Type of liquid: clean water with no suspended solids or abrasive material.– Maximum liquid temperature 40°C.– Maximum submersion under the water level 20 m.

126

1

2

3

4

56

7

89

10

11

12

Pump body X 5 CrNi 1810 (AISI 304) Stainless steelSuction grid X 16 CrNi 16 (AISI 431) Stainless steel

Base Noryl

Impeller Acetal resin

Diffuser Polycarbonate with ceramic insert in the point of wear

Diffuser cap Polycarbonate with stainless steelinserts in the point of wear

Motor shaftHexagonal, in X 10 CrNiS 1809 (AISI 303)stainless steel with ceramicinsert at the point of wear.AISI 416 for the out of water parts.

Mechanical seal Graphite

Counterface Aluminum oxide

Power cable 20 m H07 RN-F

Component Material

DESIGN FEATURES

123

4

5

6

7

8

9

10

11 No-return valve Integrated - Plastic

Discharge head Noryl with 1 1/4 threaded insert

Thrust bearing ring inserted in every stage

12

-

Page 124: Electric Pumps Catalogue

DO

MIN

ATO

R 4

TABLE OF HYDRAULIC PERFORMANCE

DOMINATOR 4

TABLE OF SIZES AND WEIGHTS

ModelDimensions mm.

A

Weight

Ø C DNM kgFree Bore

PUMP PERFORMANCE

MODELCODE

AbsorbedPower

kWHPVOLTAGE Amp. µF. Q

L/1'

m3/h

0 80NominalPower

kWHP 4,80

20

1,2

40

2,4

60

3,6

N˚Stages

127

115/57

75/56

55/50

75/35

115/36

40L / 1'm3/ h

Q

20

10 60 80 100

10

30

40

50

60

0,6

Hm 20 30 50 70 90

1,2 1,8 2,4 3,0 3,6 4,2 4,8 5,4 6,0

1 ~ 220 ÷ 240 V 500,90 0,65 38,7 170,70 0,50 3 16 DOMINATOR 4” - 55/50 M N3200020 6

1 ~ 220 ÷ 240 V 561 0,75 49,8 38,1 190,80 0,60 3,3 16 DOMINATOR 4” - 75/56 M N3200010 8

1 ~ 220 ÷ 240 V 571,50 1,10 52 44,4 31,5 16,61 0,80 16 DOMINATOR 4” - 115/57 M N3200040 85

643 98 DOMINATOR 4” - 115/57 9,92 mm 1”1/4

549 98 DOMINATOR 4” - 55/50 8,82 mm 1”1/4

643 98 DOMINATOR 4” - 75/56 9,62 mm 1”1/4

1 ~ 220 ÷ 240 V 350,80 0,60 33 26 110,50 0,35 3 12,5 DOMINATOR 4” - 75/35 M N3200110 5

1 ~ 220 ÷ 240 V 361 0,75 35 32 25 130,55 0,40 12,5 DOMINATOR 4” - 115/36 M N3200100 53,5

DOMINATOR 4” - 75/35

DOMINATOR 4” - 115/36

560 98 8,11”1/4

560 98 8,11”1/4

2 mm

2 mm

DNM

A

ø C

Dis

char

ge h

ead

in m

eter

s

Page 125: Electric Pumps Catalogue

DOMINATOR 5SUBMERSIBLE MULTISTAGE CENTRIFUGAL PUMPFOR CLEAR WATER

The DOMINATOR 5" submersible pumps are suitable for installation in traditional wells,water deposits, collection tanks, clear watercourses, lakes etc.Automatic version equipped with float switch.

• COMPLETELY IN STAINLESS STEEL

128

Motor- Dry motor with stainless steel casing cooled by the pumped liquid- Level of protection IP 68- Class F insulation- Single phase supply with capacitor permanently activated- Thermal protection built into the motor winding- Completely insulated cable connection chamber- Self-lubricating ball bearings- Speed of rotation 2850 rpm- Suitable for continuous use

Applications- Pumping of water from traditional wells- Domestic tank installations for boosting domestic drinking water systems- Small-scale automatic systems for garden irrigation- Surface irrigation

Usage limitations- Type of liquid: clean water with no suspended solids or abrasive material- Maximum liquid temperature 40° C- Maximum submersion under the water level 20 m

Pump casing X 5 CrNi 1810 (AISI 304) Stainless steel Suction grid X 5 CrNi 1810 (AISI 304) Stainless steel

Impeller X 5 CrNi 1810 (AISI 304) Stainless steel

Diffuser X 5 CrNi 1810 (AISI 304) Stainless steel

Motor shaft

Mechanical seal Graphite

Counterface Aluminium oxide

Component Material

DESIGN FEATURES

12

4

5

87

6

9

Power cable 20 m H07 RN-F with plugX CrNiMo 17-12-03 (AISI 316) Stainless steel

Spacer X 5 CrNi 1810 (AISI 304) Stainless steel

10

Oil chamber forseal lubrication

8

10

9

7

4

5

6

1

2

Page 126: Electric Pumps Catalogue

129

DO

MIN

ATO

R 5

TABLE OF HYDRAULIC PERFORMANCE

DOMINATOR 5

TABLE OF SIZES AND WEIGHTS

ModelDimensions mm.

A

Weight

Ø C DNM kgFree Bore

PUMP PERFORMANCE

MODELCODE

AbsorbedPower

kWHPVOLTAGE Amp. µF. Q

L/1'

m3/h

0 80 100 120NominalPower

kWHP 4,8 6 7,2

Dis

char

ge h

ead

in m

eter

s

140

8,40

20

1,2

40

2,4

60

3,6

N˚Stages

N3191080

N3191090

N3191100

N3191110

D 5” - 70/50 T

D 5” - 70/75 T

D 5” - 140/45 T

D 5” - 140/65 T

1 ~ 220 ÷ 240 V D 5” - 70/50 M N3191000

50.61.3 0.95 42.5 29.3 7.51 0.74.5 16 D 5” - 70/50 M AUT N3191010

6

1 ~ 220 ÷ 240 V D 5” - 70/75 M N3191020

752 1.45 60.7 41.4 17.21.4 16.5 20

D 5” - 70/75 M AUT N3191030 9

1 ~ 220 ÷ 240 V D 5” - 140/45 M N3191040

45.81.8 1.3 43.3 38.4 33.3 28 21.81.2 0.95.5 16

15.2 7.4 D 5” - 140/45 M AUT N3191050 5

1 ~ 220 ÷ 240 V D 5” - 140/65 M N319106064.52.3 1.7 60.2 53.5 46 38 27.91.5 1.1

7.5 2018.2 7.6 D 5” - 140/65 M AUT N3191070

7

3 ~ 400 V

3 ~ 400 V

3 ~ 400 V

3 ~ 400 V

1.8

2.1

2

2.6

N3191150 D 5” - 70/50 T 3 ~ 230 V 3

N3191140 D 5” - 70/75 T 3 ~ 230 V 3,7

N3191170 D 5” - 140/45 T 3 ~ 230 V 4

N3191160 D 5” - 140/65 T 3 ~ 230 V 4,5

70/50 70/75

140/45

140/65

40

Hm

L / 1'm3/ h

Q

20

20 60 80 100

6

120 140 160

10

30

40

50

60

70

4 2 8

470

520

495

550

132

132

132

132

DOMINATOR 5” - 140/45

DOMINATOR 5” - 140/65

DOMINATOR 5” - 70/75

DOMINATOR 5” - 70/50 13.7

15.5

14.2

15.8

2 mm

2 mm

2 mm

2 mm

1”1/4

1”1/4

1”1/4

1”1/4

Page 127: Electric Pumps Catalogue

• HIGH RESISTANCE TO WEAR

The K-SERIES submersible pumps consist on a multistage pumping unit directlyconnected to a submersible motor. Equipped with 30 m electric cable, 30 m nyloncord and control box.Especially suitable for pumping from deep 4” Ø wells.

K-SERIES4” SUBMERSIBLE PUMP

Applications– Water systems for residential, commercial and agricultural use– Pumping systems– Irrigation

Usage limitations– Type of liquid: clean non-aggressive, non-explosive, free of solids– Maximum environmental temp.: 30° C– Max start-up per hour: 30

Component

Pump casing

Discharge

Thrust pads

Material

Stainless steel 300 grade

Fiberglass-reinforced thermoplastic

Stainless steel 300 grade

DESIGN FEATURES

Diffusers Polycarbonate

Discharge bearing

Shaft and coupling

Nylatron

Proprietary spec.

Motor bracket Fiberglass-reinforced thermoplastique

Nylatron is a registered trademark of Polymer Corp.

Check valve Durable internal check valveCable guard Rigid PVC

1

2

34

7

891011

130

Motor– 4” submersible motor– Filled with special food grade lubricant– Motor casing, shaft and bottom end made in stainless steel– High resistance cast iron nickel plated upper bracket– Axial and radial thrust ball bearing– Standard mechanical Seal graphite\ceramic– Special Cooling fluid for a better lubricant effect to increase life of moving parts. The liquid with its high thermal capacity gives the motor superior overload capabilities– Oversize compensation diaphragm and sand slinger protection– Nema standard coupling dimensions

Control box– IP55 plastic box– Main switch with circuit breaker– Motor protector with restart button– Capacitor

2

1

5

7

8

9

10

3

6

4

11

Bowls Polycarbonate with stainless steel wear ring6

Impeller Acetal resin5

Page 128: Electric Pumps Catalogue

131

K-SERIES

K-S

ER

IES

L

D

180

1006

Q

HmL /m3/ h

2-19

2-14

4-12

2-10

4-94-7

160

140

120

100

80

60

40

20

804,8

603,6

402,4

201,2

PUMP PERFORMANCE

MODELCODE

MOTOR REQUIRED

kWQ

L/1'

m3/h

30

1,8

40

2,4

10

0,6

20

1,2HP

60

3,6

0

0

N°stages

Ø

N3186240N3186250

N3186260

K-SERIES 4-7K-SERIES 4-9

K-SERIES 4-12

N3186210

N3186220

N3186230

K-SERIES 2-10

K-SERIES 2-14

K-SERIES 2-19

0,75 0,55

1 0,75

1,5 1,1

7

9

12

4”

4”

4”

54

68

91

76

104

144

52

66

88

65

91

125

50

63

85

50

75

99

48

60

80

31

52

63

45

56

75

35

44

59

0,75 0,55

1 0,75

1,5 1,1

10

14

19

83

112

158

4”

4”

4”

22

28

37

80

4,8

Dis

char

ge h

ead

in m

eter

s

K-SERIES 4-9 350 21,1432

K-SERIES 4-7 325 19,1375

K-SERIES 4-12 385 23,5518

TABLE OF SIZES AND WEIGHTS

ModelDimensions mm.

A

Weight

kgB

K-SERIES 2-10 325 20,1400

K-SERIES 2-19 385 26,3600

K-SERIES 2-14 350 22488

782

700

903

L

725

985

838

95

95

95

D Ø

95

95

95

B

A

TABLE OF HYDRAULIC PERFORMANCE

V

1~230

1~230

1~230

1~230

1~230

1~230

Page 129: Electric Pumps Catalogue

Component

Pump casing

Discharge

Bowls

Material

Stainless steel 300 grade

Fiberglass-reinforced thermoplastic

Proprietary spec.

DESIGN FEATURES

Diffusers Polycarbonate

Discharge bearing

Thrust pads

Nylatron

Polycarbonate with stainless steel wear ring

Shaft and coupling Stainless steel 300 grade

Nylatron is a registered trademark of Polymer Corp.

Motor bracket Fiberglass-reinforced thermoplasticCheck valve Durable internal check valveCable guard Rigid PVC

1

2

34

6

7891011

Impeller Acetal resin5

• HIGH RESISTANCE TO WEAR

The K-Series pump ends are designed with a corrosive resistant stainless steel wearsurface that greatly reduces problems with abrasives and sand lock-up.Particularly suitable for pumping from 4” wells.Floating impeller staging system.

K-SERIES4” SUBMERSIBLE PUMP END

Applications- Water systems for residential, commercial and agricultural use- Pumping systems- Irrigation

Usage limitations- Motor bracket suitable for 4” NEMA flange- Type of liquid: clean, non-aggressive, non-explosive, free of solids- Max liquid temperature: 30° C

132

2

1

5

7

8

9

10

3

6

4

11

Page 130: Electric Pumps Catalogue

133

N1059150N1059160

N1059170

N1059180

K-SERIES 4-7K-SERIES 4-9

K-SERIES 4-12

K-SERIES 4-17

TABLE OF HYDRAULIC PERFORMANCE

PUMP PERFORMANCE

MODELCODE

MOTOR REQUIRED

kWQ

L/1'

m3/h

30

1,8

40

2,4

10

0,6

20

1,2HP

60

3,6

0

0

Dis

char

ge h

ead

in m

eter

s

N°stages

Ø

K-SERIES PUMP ENDS

K-S

ER

IES P

UM

P E

ND

S

N1059110N1059120

N1059130

N1059140

K-SERIES 2-7K-SERIES 2-10

K-SERIES 2-14

K-SERIES 2-19

0,5 0,37

0,75 0,55

1 0,75

1,5 1,1

58

TABLE OF SIZES AND WEIGHTS

ModelDimensions mm.

L

Weight

kgD

K-SERIES 2-10 400 6,995

K-SERIES 2-7 334 4,295

K-SERIES 2-19 600 10,495

K-SERIES 2-14 488 7,795

180

7

10

14

19

83

112

158

4”

4”

4”

4”

1006

Q

HmL / 1'm3/ h

L

D

0,75 0,55

1 0,75

1,5 1,1

2 1,5

7

9

12

17

4”

4”

4”

4”

K-SERIES 4-9 432 6,895

K-SERIES 4-7 375 5,995

K-SERIES 4-17 661 12,395

K-SERIES 4-12 518 7,695

2-19

4-17

2-14

4-12

2-10

4-92-7

4-7

160

140

120

100

80

60

40

20

804,8

603,6

402,4

201,2

54

68

91

130

54

76

104

144

52

66

88

127

48

65

91

125

50

63

85

121

39

50

75

99

48

60

80

117

26

31

52

63

45

56

75

110

35

44

59

89

22

28

37

56

80

4,8V

1~230

1~230

1~230

1~230

1~230

1~230

1~230

1~230

Page 131: Electric Pumps Catalogue

SCM 4 Plus4" MULTISTAGE CENTRIFUGAL SUBMERSIBLE PUMPSCOMPLETE WITH MOTOR

• HIGH STIFFNESS AND HIGH RESISTANCE TO WATER HAMMERING• HIGH SAND ABRASION RESISTANCE• HIGH HYDRAULIC EFFICIENCY

134

Motor- 4" submersible motor- Special resin impregnated sealed stator- Water-cooled thrust bearings and bushes- Approx. 1.5 m extendible power supply cable- Non-polluting water cooling- 4" NEMA flange- Level of protection IP 68- Class B insulation- Speed of rotation 2850 rpm- Special mechanical seal with sand guard- Pressure compensation diaphragm- Supplied without capacitor (single phase version)- Suitable for continuous use- Electrical control panel on request

Applications- Pumping of water from drilled wells- Automatic systems for garden irrigation- Surface irrigation for agricultural use- Drinking water systems- Pumping and supply of stored deposits or of booster autoclaves for civil and industrial systems- Heat pumps

Usage limitations- Type of liquid: clean non-aggressive, non-explosive, free of solids- Maximum liquid temperature 30° C- Max. start-ups per hour 20- Motor protection with thermal relay provided by the user

Component

Outlet

Suction flange

Check valve

Filter

Impeller

Diffuser

Material

X 5 CrNi 1810 (AISI 304) Microcast stainless steel

X 5 CrNi 1810 (AISI 304) microcast stainless steel

X 5 CrNi 1810 (AISI 304) Stainless steel

DESIGN FEATURES

12

3 Pump casing45

Acetal resin

67

Polycarbonate with ceramic insert at the point of wear8

Cable protection trough X 5 CrNi 1810 (AISI 304) Stainless steel

X 5 CrNi 1810 (AISI 304) Stainless steel

9

Motor shaft Hexagonal in X10 CrNiS 1809 (AISI 303)Stainless steel with ceramic facing on the upper end10

Self-lubricatingdelivery bearing

Molybdenum bisulphide polyamide11

X 5 CrNi 1810 (AISI 304) Stainless steel

Cap diffuser Polycarbonate with steel insert series 300

The SCM 4 PLUS submersible pumps consist of a multistage pumping unit directlyconnected to a submersible motor.Especially suitable for pumping from deep 4'' (100mm) Ø wells.

Thrust ring inserted in every stage-

1

2

3

4

5

6

7

8

9

10

11

Page 132: Electric Pumps Catalogue

135

SCM 4 Plus

SC

M 4

Plu

s

Delivery connectionpoint in microcast AISI304 stainless steel withan internal tapereddouble profile with astainless steel nonreturn valve and adouble slot for safetycable.

BENEFITS:It resets flow resistanceoffering maximumrigidity and highresistance to protect thepump against waterhammering.

Shaft guide bearingmade with a self-lubricating closed bushin molybdenumbisulphide polyamideand stainless steel shaftwith ceramic insert atthe point of wear.

BENEFITS:Increases the life of thepump - protectionagainst dry operation -high resistance to wearcaused by sand.

Floating impeller withsuction point shim onstainless steel mouldedwith a diffusor cover.Thrust bearing insertedbetween the hub of theimpeller and diffusorformed by one ceramicring moulded with thediffusor and a free ringin graphite."International Patent"

BENEFITS:This extraordinarytechnological innovationleads to a large increasein efficiency as well ashigh resistance toabrasion by sand andto dry operation.

Motor bracket andsuction point inmicrocast AISI 304stainless steel rigidlywelded to the outerstainless steel liner.Stainless steel suctiongrid.

BENEFITS:This system offers highresistance tomechanical stressescaused by operatingpressure.Maximum rigidity of thewhole structureeliminates vibrations.

Page 133: Electric Pumps Catalogue

TABLE FOR CALCULATING PUMP LENGTH

96

DNM

A

CB

105

L

SCM 4 Plus

136

SCM 4 PLUS 40/57 M 576 SCM 4 PLUS 40/57 T SCM 4 PLUS 40/90 M SCM 4 PLUS 40/90 T SCM 4 PLUS 40/120 M SCM 4 PLUS 40/120 T SCM 4 PLUS 40/185 M SCM 4 PLUS 40/185 T SCM 4 PLUS 40/240 M SCM 4 PLUS 40/240 T

557717688857829

1109108113391310

242223271242299271327299356327

334334446446558558782782983983

730710870840

1010980

1260123014901460

11.810.814.012.716.114.919.217.922.220.8

SCM 4 PLUS 55/50 M 509 SCM 4 PLUS 55/50 T SCM 4 PLUS 55/80 M SCM 4 PLUS 55/80 T SCM 4 PLUS 55/105 M SCM 4 PLUS 55/105 T SCM 4 PLUS 55/160 M SCM 4 PLUS 55/160 T SCM 4 PLUS 55/200 M SCM 4 PLUS 55/200 T SCM 4 PLUS 55/300 T

490628599700672862834

1026997

1317

242223271242299271327299356327356

267267357357401401535535670670961

660640780750850830

1012990

118011501470

11.310.313.111.814.913.717.316.019.818.422.3

SCM 4 PLUS 75/40 M 545 SCM 4 PLUS 75/40 T SCM 4 PLUS 75/56 M SCM 4 PLUS 75/56 T SCM 4 PLUS 75/75 M SCM 4 PLUS 75/75 T SCM 4 PLUS 75/110 M SCM 4 PLUS 75/110 T SCM 4 PLUS 75/140 M SCM 4 PLUS 75/140 T SCM 4 PLUS 75/210 T

526631602744716915887

105810291372

242223271242299271327299356327356

303303360360445445588588702702

1016 15201180120010401070870900750780680700 11.2

10.212.911.614.813.617.115.819.418.021.5

SCM 4 PLUS 115/30 M 488 SCM 4 PLUS 115/30 T SCM 4 PLUS 115/50 M SCM 4 PLUS 115/50 T SCM 4 PLUS 115/65 M SCM 4 PLUS 115/65 T SCM 4 PLUS 115/95 M SCM 4 PLUS 115/95 T SCM 4 PLUS 115/122 M SCM 4 PLUS 115/122 T SCM 4 PLUS 115/185 T SCM 4 PLUS 115/245 T

469602573687659829801973944

12021525

242223271242299271327299356327356423

246246331331388388502502617617846

1102

640620750720840810980950

1120110013501680

11.010.012.811.514.413.216.615.318.817.420.825.0

SCM 4 PLUS 150/42 M 652 SCM 4 PLUS 150/42 T SCM 4 PLUS 150/64 M SCM 4 PLUS 150/64 T SCM 4 PLUS 150/84 M SCM 4 PLUS 150/84 T SCM 4 PLUS 150/120 T SCM 4 PLUS 150/170 T SCM 4 PLUS 150/200 T SCM 4 PLUS 150/300 T

624790762929900

1142146618162407

299271327299356327356423590704

353353463463573573786

104312261703

800780940910

108010501300162019702560

14.012.816.114.818.316.920.124.233.142.3

SCM 4 PLUS 250/53 M 951 SCM 4 PLUS 250/53 T SCM 4 PLUS 250/78 T SCM 4 PLUS 250/100 T SCM 4 PLUS 250/127 T SCM 4 PLUS 250/185 T

9221186155018332462

356327356514590704

595595830

103612431758

110010701340170019832612 42.6

29.623.918.015.618.0

2"

1" 1/4

MODEL ATotal

lengthmm.

BMotorlengthmm.

CPumplengthmm.

DNM LPackinglength

Totalweight

Kg.

Page 134: Electric Pumps Catalogue

137

SC

M 4

Plu

s

SCM 4 Plus 40

TABLE OF HYDRAULIC PERFORMANCE

PUMP PERFORMANCE

MODELCODE

Motorpower

VOLTAGE Amp. µF. QL/1'

m3/h

10

0,6

40

2,4 DNM

20

1,2

30

1,8HP Kw

ØN˚

Stages

The power curve refers to the brake horse power (BHP) per stage. % indicates the pump hydraulic efficiency

9

14

29

38

19

SCM 4 PLUS-40/57 M SCM 4 PLUS-40/57 T 49 41 26 3

SCM 4 PLUS-40/90 M SCM 4 PLUS-40/90 T

76 64 40 4

104 86 55 7

158 130 85 10

N3181000 N3181010

N3181020 N3181030

0,5 0,371 ~ 230 V3 ~ 400 V

0,75 0,551 ~ 230 V3 ~ 400 V

1 0,75

1,5 1,1

205 160 110 122 1,5

N3181040 N3181050

N3181060 N3181070

N3181080 N3181090

SCM 4 PLUS-40/120 M SCM 4 PLUS-40/120 T

SCM 4 PLUS-40/185 M SCM 4 PLUS-40/185 T

SCM 4 PLUS-40/240 M SCM 4 PLUS-40/240 T

1 ~ 230 V3 ~ 400 V

1 ~ 230 V3 ~ 400 V

1 ~ 230 V3 ~ 400 V

3,41,1

4,31,6

5,72,1

8,63,2

10,64

16

20

30

40

50

1"1/4

Dis

char

ge h

ead

in m

eter

s

Page 135: Electric Pumps Catalogue

SCM 4 Plus 55

138

TABLE OF HYDRAULIC PERFORMANCE

PUMP PERFORMANCE

MODELCODE

Motorpower

VOLTAGE Amp. µF. QL/1'

m3/h

10

0,6

50

3

20

1,2

30

1,8HP Kw

40

2,4

6

10

12

18

24

37

SCM 4 PLUS-55/50 M SCM 4 PLUS-55/50 T

N3182000 N3182010

0,5 0,371 ~ 230 V3 ~ 400 V

SCM 4 PLUS-55/80 M SCM 4 PLUS-55/80 T

N3182020 N3182030

0,75 0,551 ~ 230 V3 ~ 400 V

SCM 4 PLUS-55/105 M SCM 4 PLUS-55/105 T

1 0,751 ~ 230 V3 ~ 400 V

SCM 4 PLUS-55/160 M SCM 4 PLUS-55/160 T

1,5 1,11 ~ 230 V3 ~ 400 V

SCM 4 PLUS-55/200 M SCM 4 PLUS-55/200 T

2 1,51 ~ 230 V3 ~ 400 V

SCM 4 PLUS-55/300 T 3 2,2 3 ~ 400 V

N3182040 N3182050

N3182060 N3182070

N3182080 N3182090

N3182100

3,21,1

4,31,6

5,32,1

7,83,2

9,94

5,9

16

20

30

40

50

1"1/4

47

75

98

145

187

278

42

66

87

132

169

244

36

55

72

110

145

200

23

35

46

70

90

140

8

12

12

24

30

50

DNM

ØN˚ Stages

The power curve refers to the brake horse power (BHP) per stage. % indicates the pump hydraulic efficiency

Dis

char

ge h

ead

in m

eter

s

Page 136: Electric Pumps Catalogue

139

SC

M 4

Plu

s

SCM 4 Plus 75

TABLE OF HYDRAULIC PERFORMANCE

PUMP PERFORMANCE

MODELCODE

Motorpower

VOLTAGE Amp. µF. QL/1'

m3/h

50

3

20

1,2

30

1,8HP Kw

40

2,4

1"1/4

DNM

Ø

Dis

char

ge h

ead

in m

eter

s

60

3,6

6

8

11

16

20

30

36

50

67

100

127

186

33

45

62

92

116

170

28

40

55

82

105

155

23

32

45

68

86

130

15

21

30

44

57

80

SCM 4 PLUS-75/40 M SCM 4 PLUS-75/40 T

N3183000 N3183010 0,5 0,37

1 ~ 230 V3 ~ 400 V

SCM 4 PLUS-75/56 M SCM 4 PLUS-75/56 T 0,75 0,55

1 ~ 230 V3 ~ 400 V

SCM 4 PLUS-75/75 M SCM 4 PLUS-75/75 T SCM 4 PLUS-75/75 T

1 0,751 ~ 230 V3 ~ 400 V3 ~ 230 V

SCM 4 PLUS-75/110 M SCM 4 PLUS-75/110 T 1,5 1,1

1 ~ 230 V3 ~ 400 V

SCM 4 PLUS-75/140 M SCM 4 PLUS-75/140 T 2 1,5

1 ~ 230 V3 ~ 400 V

SCM 4 PLUS-75/210 T 3 2,2 3 ~ 400 V N3183100

N3183020 N3183030 N3183040 N3183050 N3186140

N3183060 N3183070

N3183080 N3183090

3,21,1

4,31,65,32,13,77,83,2

9,94

5,9

16

20

30

40

50

N˚ Stages

The power curve refers to the brake horse power (BHP) per stage. % indicates the pump hydraulic efficiency

Page 137: Electric Pumps Catalogue

SCM 4 Plus 115

140

TABLE OF HYDRAULIC PERFORMANCE

PUMP PERFORMANCE

MODELCODE

Motorpower

VOLTAGE Amp. µF. QL/1'

m3/h

50

3

30

1,8HP Kw

40

2,4

1"1/4

DNM

Ø

Dis

char

ge h

ead

in m

eter

s

60

3,6

80

4,8

90

5,4

100

6

4

7

9

13

17

24

33

SCM 4 PLUS-115/30 M SCM 4 PLUS-115/30 T 26

N3184000 N3184010 0,5 0,37

1 ~ 230 V3 ~ 400 V

SCM 4 PLUS-115/50 M SCM 4 PLUS-115/50 T 0,75 0,55

1 ~ 230 V3 ~ 400 V

SCM 4 PLUS-115/65 M SCM 4 PLUS-115/65 T SCM 4 PLUS-115/65 T

1 0,751 ~ 230 V3 ~ 400 V3 ~ 230 V

SCM 4 PLUS-115/95 M SCM 4 PLUS-115/95 T SCM 4 PLUS-115/95 T

1,5 1,11 ~ 230 V3 ~ 400 V3 ~ 230 V

SCM 4 PLUS-115/122 M SCM 4 PLUS-115/122 T 2 1,5

1 ~ 230 V3 ~ 400 V

SCM 4 PLUS-115/185 T 3 2,2 3 ~ 400 V N3184100

SCM 4 PLUS-115/245 T 4 3 3 ~ 400 V N3184110

N3184020 N3184030 N3184040 N3184050 N3186150 N3184060 N3184070 N3186160 N3184080 N3184090

46

58

83

109

160

218

24 22 20 13 9 6,4

43 40 36 23 16 10

55 51 46 29 20 11

80 74 67 43 30 18

106 98 88 55 38 21

153 143 130 85 58 31

210 198 179 118 84 47

3,21,1

4,31,65,32,13,77,83,25,29,94

5,9

7,8

16

20

30

40

50

N˚ Stages

The power curve refers to the brake horse power (BHP) per stage. % indicates the pump hydraulic efficiency

Page 138: Electric Pumps Catalogue

141

SC

M 4

Plu

s

SCM 4 Plus 150

TABLE OF HYDRAULIC PERFORMANCE

PUMP PERFORMANCE

MODELCODE

Motorpower

VOLTAGE Amp. µF. QL/1'

m3/h

60

3,6

40

2,4HP Kw

50

3

2”

DNM

Ø

Dis

char

ge h

ead

in m

eter

s

80

4,8

100

6

120

7,2

140

8,4

6

9

12

17

24

29

42

SCM 4 PLUS-150/42 M SCM 4 PLUS-150/42 T SCM 4 PLUS-150/42 T

38 N3185000 N3185010 N3186170

1 0,751 ~ 230 V3 ~ 400 V3 ~ 230 V

SCM 4 PLUS-150/64 M SCM 4 PLUS-150/64 T SCM 4 PLUS-150/64 T

1,5 1,11 ~ 230 V3 ~ 400 V3 ~ 230 V

SCM 4 PLUS-150/84 M SCM 4 PLUS-150/84 T SCM 4 PLUS-150/84 T

2 1,51 ~ 230 V3 ~ 400 V3 ~ 230 V

3 2,2

4 3

SCM 4 PLUS-150/200 T 5,5 4 3 ~ 400 V

SCM 4 PLUS-150/300 T 7,5 5,5 3 ~ 400 V

59

80

116

160

191

292

37 36 33 26 17 10

58 57 50 39 27 15

78 75 64 50 34 20

113 108 96 77 53 26

157 152 134 106 69 30

188 179 152 112 71 32

290 285 252 210 155 82

SCM 4 PLUS-150/170 T

N3185020 N3185030 N3186180 N3185040 N3185050 N3186190

N3185060 SCM 4 PLUS-150/120 T

N3185070

N3185080

N3185090

3 ~ 400 V

3 ~ 400 V

5,32,13,77,83,25,29,94

6,9

10

13,7

7,8

5,9

30

40

50

N˚Stages

The power curve refers to the brake horse power (BHP) per stage. % indicates the pump hydraulic efficiency

Page 139: Electric Pumps Catalogue

SCM 4 Plus 250

142

TABLE OF HYDRAULIC PERFORMANCE

PUMP PERFORMANCE

MODELCODE

Motorpower

VOLTAGE Amp. µF. QL/1'

m3/h

140

8,4

100

6HP Kw

120

7,2

2"

DNM

Ø

Dis

char

ge h

ead

in m

eter

s

180

10,8

200

12

220

13,2

240

14,4

9

13

17

21

31

SCM 4 PLUS-250/53 M SCM 4 PLUS-250/53 T SCM 4 PLUS-250/53 T

43

SCM 4 PLUS-250/78 T 63

83

106

N3186000 N3186010 N3186200

N3186020

2 1,51 ~ 230 V3 ~ 400 V3 ~ 230 V

3 2,2 3 ~ 400 V

4 3

5,5 4

1527,5 5,5

N3186030

N3186040

N3186050

SCM 4 PLUS-250/100 T

SCM 4 PLUS-250/127 T

SCM 4 PLUS-250/185 T

3 ~ 400 V

3 ~ 400 V

3 ~ 400 V

41 37 26 18 11

59 54 41 30 18

78 66 54 41 24

100 90 68 49 31

141 127 81 57 36

4

7

9

14

18

9,94

6,9

5,9

7,8

10

13,7

50

N˚Stages

The power curve refers to the brake horse power (BHP) per stage. % indicates the pump hydraulic efficiency

Page 140: Electric Pumps Catalogue

4” MULTISTAGE CENTRIFUGAL SUBMERSIBLEPUMPS COMPLETE WITH MOTOR

SCM 4 HF 400

143

Motor– 4” submersible motor– Special resin impregnated sealed stator– Water-cooled thrust bearings and bushes– Approx. 1,5 m extendible power supply cable– Non-polluting water cooling– 4” NEMA flange– Level of protection IP68– Class B insulation– Speed of rotation 2850 rpm– Special mechanical seal with sand guard– Pressure compensation diaphragm– Supplied without capacitor (single phase version)– Suitable for continuous use– Electrical control panel on request

Applications– Pumping of water from drilled wells– Automatic systems for garden irrigation– Surface irrigation for agricultural use– Drinking water systems– Pumping and supply of stored deposits or of booster autoclaves for civil and industrial systems– Heat pumps

Usage limitations- Type of liquid: clean, non aggressive, non-explosive, free of solids- Maximum liquid temperature 30° C- Max. start-ups per hour 20- Motor protection with thermal relay provided by the user

SCM 4HF 400 high flow rate submersible pumps consist of a multistage hydraulic enddirectly connected to a submersible motor. Especially suitable for pumping from deepØ 4” (100 mm) wells

Washer / thrust

Component

Discharge

Motor bracket

Screen

ImpellerDiffuser

Material

300 series stainless steel - 2” BSP threads

Microcast stainless steel (300 series)

300 series stainless steel

DESIGN FEATURES

12

3 Shell45

Glass filled Polycarbonate6

7Glass filled Noryl®

8

• BUILT TO DELIVER LONG TERM, TROUBLE-FREE SERVICE• HIGH HYDRAULIC EFFICIENCY• HIGH FLOW

Cable guard 300 series stainless steel

9

Motor shaft (hydraulic end)

Acetal

10

Top bearing

Phenolic

300 series stainless steel

Hexagonal in stainless steel (300 series)Thrust ring inserted in every stage

1

8

7

6

4

2

10

3

5

9

Page 141: Electric Pumps Catalogue

144

SCM 4 HF 4004” MULTISTAGE CENTRIFUGAL SUBMERSIBLE PUMPS COMPLETE WITH MOTOR

0 20 40 60 80 100

120

100

80

60

40

20

0 50 100 150 200 250 300 350 4000

100

200

300

400

CAPACITY U.S. GALLONS PER MINUTE

CAPACITY LITRES PER MINUTE

TOTA

L H

EA

D IN

ME

TER

S

TOTA

L H

EA

D IN

FE

ET400/100

400/80

400/50

400/30

TABLE OF HYDRAULIC PERFORMANCE

DIMENSIONS AND WEIGHTS

MODEL

Dimension mm.

A B DNM

kg

C

2536 698SCM4HF 400/100 T 39,41838 2” BSP

914 384SCM4HF 400/30 M 21,5530 2” BSP

1036 356SCM4HF 400/50 T 21,5680 2” BSP

SCM4HF 400/30 T

SCM4HF 400/80 T

857 327 192” BSP

2060 584 332” BSP

530

1476

Weight

kg

29,4

14,5

13,5

12

24

kg

10

7

8

7

9

Totallength

Motorlength

Pumplength

total motor pump

PUMP PERFORMANCE

CODEMotorPower

kWVOLTAGE Amp. µF. Q

L/1'

m3/h

100 300 350

HP 15 216

150

9

200

12

250

15N˚

stages

7

96

DNM

A

CB

105

L

MODEL

3 ~ 400 V2,23 39,2 35,5 31,143 25,1 19,25,9 11

3 ~ 400 V45,5 65 57,7 50,371 42,2 32,610 18

3 ~ 400 V5,57,5 88,8 80 69,696,3 57,7 4313,7 23

Disc

harg

e he

adin

met

ers

1 ~ 230 V1,52 25 22,2 19,527,4 15,5

9,950

3 ~ 400 V 4

SCM4HF 400/50 T

SCM4HF 400/80 T

SCM4HF 400/100 T

SCM4HF 400/30 M

SCM4HF 400/30 T

N3186110

N3186120

N3186130

N3186090

N3186100

Page 142: Electric Pumps Catalogue

145

SC

M 4

Plu

s /

HF P

UM

P-E

ND

SCM 4 Plus / HF PUMP-ENDSUBMERSIBLE PUMPS

N1050120

CODE

SCM 4 PLUS 75/40

MODEL

36

20Ql/1'

33

30

28

40

23

50

15

60 NECESSARYMOTOR

HP 0,5

Dis

char

ge h

ead

in m

eter

s

N1050020 SCM 4 PLUS 40/90 76 64 40 4 HP 0,75

N1050030 SCM 4 PLUS 40/120 104 86 55 7 HP 1

N1050040 SCM 4 PLUS 40/185 158 130 85 10 HP 1,5

N1050050 SCM 4 PLUS 40/240 205 160 110 12 HP 2

N1050060 SCM 4 PLUS 55/50 47 42 36 23 8 HP 0,5

N1050070 SCM 4 PLUS 55/80 75 66 55 35 12 HP 0,75

N1050080 SCM 4 PLUS 55/105 98 87 72 46 15 HP 1

N1050090 SCM 4 PLUS 55/160 145 132 110 70 24 HP 1,5

N1050100 SCM 4 PLUS 55/200 187 169 145 90 30 HP 2

N1050110 SCM 4 PLUS 55/300 278 244 200 140 50 HP 3

N1050130 SCM 4 PLUS 75/56 50 45 40 32 21 HP 0,75

N1050140 SCM 4 PLUS 75/75 67 62 55 45 30 HP 1

N1050150 SCM 4 PLUS 75/110 100 92 82 68 44 HP 1,5

N1050160 SCM 4 PLUS 75/140 127 116 105 86 57 HP 2

N1050170 SCM 4 PLUS 75/210 186 170 155 130 80 HP 3

CODE MODEL 10Ql/1' 20 30 40 NECESSARYMOTOR

Dhi

scar

ge h

ead

in m

eter

s

CODE MODEL 10Ql/1' 20 30 40 50 NECESSARYMOTOR

Dhi

scar

ge h

ead

in m

eter

s

N1050010 SCM 4 PLUS 40/57 49 41 37 26 HP 0,5

Page 143: Electric Pumps Catalogue

SCM 4 Plus / HF PUMP-END

146

SUBMERSIBLE PUMP

100 150 200 250 300 350CODE MODEL Ql/1' NECESSARYMOTOR

100 120 140 180 200 220 240CODE MODEL Ql/1' NECESSARYMOTOR

CODE MODEL Ql/1' 40 50 60 80 100 120 140 NECESSARYMOTOR

CODE MODEL 30Ql/1' 40 50 60 80 90 100 NECESSARYMOTOR

N1050180 SCM 4 PLUS 115/30 26 24 22 20 HP 0,513 9 6,4

N1050190 SCM 4 PLUS 115/50 46 43 40 36 HP 0,7523 16 10

N1050200 SCM 4 PLUS 115/65 58 55 51 46 HP 129 20 11

N1050210 SCM 4 PLUS 115/95 83 80 74 67 HP 1,543 30 18

N1050220 SCM 4 PLUS 115/122 109 106 98 88 HP 255 38 21

N1050230 SCM 4 PLUS 115/185 160 153 143 130 HP 385 58 31

N1050240 SCM 4 PLUS 115/245 218 210 198 179 HP 4118 84 47

N1050250 SCM 4 PLUS 150/42 38 37 36 33 HP 126 17 10

N1050260 SCM 4 PLUS 150/64 59 58 57 50 HP 1,539 27 15

N1050270 SCM 4 PLUS 150/84 80 78 75 64 HP 250 34 20

N1050280 SCM 4 PLUS 150/120 116 113 118 96 HP 377 53 26

N1050290 SCM 4 PLUS 150/170 160 157 152 134 HP 4106 69 30

N1050300 SCM 4 PLUS 150/200 191 188 179 152 HP 5,5112 71 32

N1050310 SCM 4 PLUS 150/300 292 290 285 252 HP 7,5210 255 82

N1050320 SCM 4 PLUS 250/53 43 41 37 26 HP 218 11 4

N1050330 SCM 4 PLUS 250/78 63 59 54 41 HP 330 18 7

N1050340 SCM 4 PLUS 250/100 83 78 66 54 HP 441 24 9

N1050350 SCM 4 PLUS 250/127 106 100 90 68 HP 5,549 31 14

N1050360 SCM 4 PLUS 250/185 152 141 127 81 HP 7,557 36 18

N1057980 SCM 4HF 400/30 27,4 25 22,2 19,5 HP 215,5

N1057990 SCM 4HF 400/50 43 39,2 35,5 31,1 HP 325,1 19,2

N1058000 SCM 4HF 400/80 71 65 57,7 50,3 HP 5,542,2 32,6

N1058010 SCM 4HF 400/100 96,3 88,8 80 69,6 HP 7,557,7 43

Dis

char

ge h

ead

in m

eter

sD

isch

arge

hea

d in

met

ers

Dis

char

ge h

ead

in m

eter

sD

isch

arge

hea

d in

met

ers

Page 144: Electric Pumps Catalogue

147

MO

TO

RS 4

MOTORS 4”4” SUBMERSIBLE MOTORS FOR SCM 4 PLUSNEMA SPEC WITH PART ELECTRICAL CABLE

WATER COOLED

OIL COOLED

Hz

Hz

222P0540-C 3 2,2 1 ~ 230V 50

Hz

Hz

222P0010 0,5 0,37 1 ~ 230V 50

221P0030 0,5 0,37 3 ~ 400V 50

222P0020 0,75 0,55 1 ~ 230V 50

221P0040 0,75 0,55 3 ~ 400V 50

222P0030 1 0,74 1 ~ 230V 50

221P0050 1 0,74 3 ~ 400V 50

222P0040 1,5 1,1 1 ~ 230V 50

221P0060 1,5 1,1 3 ~ 400V 50

222P0050 2 1,5 1 ~ 230V 50

221P0070 2 1,5 3 ~ 400V 50

221P0080 3 2,2 3 ~ 400V 50

221P1010 4 3 3 ~ 400V 50

221P1000 5,5 4 3 ~ 400V 50

221P0740-C 0,5 0,37 3 ~ 400V 50

221P0750-C 0,75 0,55 3 ~ 400V 50

221P0760-C 1 0,74 3 ~ 400V 50

221P0990-C 1 0,74 3 ~ 230V 50

221P0770-C 1,5 1,1 3 ~ 400V 50

222P0390-C 0,5 0,37 1 ~ 230V 50

222P0400-C 0,75 0,55 1 ~ 230V 50

222P0310-C 1 0,74 1 ~ 230V 50

222P0320-C 1,5 1,1 1 ~ 230V 50

222P0330-C 2 1,5 1 ~ 230V 50

221P0600-C 5,5 4 3 ~ 400V 50

221P0590-C 4 3 3 ~ 400V 50

221P0580-C 3 2,2 3 ~ 400V 50

221P0920-C 2 1,5 3 ~ 230V 50

221P0570-C 2 1,5 3 ~ 400V 50

221P0910-C 1,5 1,1 3 ~ 230V 50

221P0610-C 7,5 5,5 3 ~ 400V 50

VOLTAGE

VOLTAGE

VOLTAGE

CODEHP kW

POWER VOLTAGE

CODEHP kWPOWER

CODEHP kWPOWER

CODEHP kWPOWER

Page 145: Electric Pumps Catalogue

6TS pumps series feature heavy duty 304 stainless steel construction.The state of the art hydraul ics provide increased pump eff iciencyand reduced energy costs. Complete range of pumps and motors with flow rates of0-75 m3/h.

• HEAVY-DUTY 304 STAINLESS STEEL CONSTRUCTION• HIGH EFFICIENCY PERFORMANCE IN 6 FLOW SERIES UP TO 75 m3/h• HIGH RESISTANCE TO WEAR CAUSED BY SAND AND OTHER ABRASIVE MATERIAL

6TS

148

6" STAINLESS STEEL SUBMERSIBLE PUMPS

Motor- 6" Franklin submersible motor- Special resin impregnated sealed stator- Water-cooled thrust bearings and bushes- Approx. 4 m extendible power supply cable- Non-polluting water cooling- 6" NEMA flange- Level of protection IP68. Class F insulation- Speed of rotation 2850 rpm- Special mechanical seal with sand guard- Pressure compensation diaphragm- Suitable for continuous use- Electrical control panel on request- Direction of rotation anticlockwise (seen from the delivery end)

Applications- Civil and industrial supply systems- Overhead or surface irrigation- Boosting- Various civil and industrial applications- Mains water supply systems

Usage limitations- Type of liquid: clean non-aggressive, non-explosive, free of solids- Maximum liquid temperature 30° C- Max. start-ups per hour: 20- Motor protection with thermal relay provided by the user- Maximum quantity of sand present: 50 g/m3

Component

Bowl bearing

Discharge bracket

Check valve

Bowl wear rings

Material

Nitrile rubber NBR

304 stainless steel

304 stainless steel

DESIGN FEATURES

123 Top bearing journal

45

Buna rubber7

Hard chrome-plated

6 Diffuser bowl 304 stainless steel

Impeller 304 stainless steel

Pump shaft 416 stainless steel8

Shaft sleeve 304 stainless steel9

Suction motor bracket 304 stainless steel10

Strainer 304 stainless steel11

Shaft coupling 416 stainless steel12

Page 146: Electric Pumps Catalogue

149

6TS

6TS

500 1000

50

100

0

H(m)

Performance range

10 30 40 60 70 80

150

200

250

300

350

400

450

5020Q

(l / min)(m3/ h)

6TS-11 6TS-22

6TS-27 6TS-30 6TS-46 6TS-60

Page 147: Electric Pumps Catalogue

6TS

150

Features / Benefits

1

2

3

4

5

6

7

8

Heavy-duty, investment cast 304stainless steel dischargeassures secure connection to drop pipe.Wrench flats provide positive grip duringinstallation.

1

Built-in check valveprevents backflow and reverse rotation.

2

Hard chrome-plated top bearing journalreduces abrasive wear in harsh sandywell conditions.

3

Durable and proven buna-rubber wearrings improve pump efficiency - theprofessional’s choice.

4

Low-profile stainless steel lead guardaids installation in narrow wells.

5

Built-in up-thrust protection protectspump during periods of high demand andstart-up, preventing pump failure.

6

304 stailess steel inlet screen andinternal coupling screen prevents entryof abrasives into pump and couplingareas.

7

Heavy-duty investment cast 304stainless steel suction bracket assuresperfect pump-to-motor alignment withany NEMA-standard submersible motor.

8

State-of-the-art fusion-welding processutilizes higher amps with lower voltage,resulting in stronger, longer-lasting,corrosion-resistant welds-significantlyreducing the onste of crecive corrosionfound in most competitor’s pumps.

9

Page 148: Electric Pumps Catalogue

151

6TS -

11

6TS - 11

TABLE OF HYDRAULIC PERFORMANCE

PUMP PERFORMANCE

0

100

6

133

8

167

10

3 ~ 400 V 12,4 11,0 10,51 0,75 2,16TS 11-1N3210000

In (A) Ql/min

m3/h

0 267

kWHP 16MODELCODE VOLTAGE ( V )

Dis

char

ge

hea

din

met

ers

1

N˚Stages SIZE

4”

200

12

233

14

9,8 8,8 7,5 5,7

3 ~ 400 V 37 32 312 1,5 46TS 11-3N3210010 3 4” 29 26 22 16

3 ~ 400 V 50 43 413 2,2 5,96TS 11-4N3210020 4 4” 39 35 30 22

3 ~ 400 V 98 85 805,5 4 106TS 11-8N3210030 8 4” 74 66 56 41

3 ~ 400 V 98 85 805,5 4 9,36TS 11-8N3210050 8 6” 74 66 56 41

3 ~ 400 V 147 127 1207,5 5,5 13,76TS 11-12N3210040 12 4” 111 99 83 62

3 ~ 400 V 147 127 1207,5 5,5 12,56TS 11-12N3210060 12 6” 111 99 83 62

3 ~ 400 V 196 170 16110 7,5 166TS 11-16N3210070 16 6” 149 133 111 83

3 ~ 400 V 233 202 19112,5 9,3 20,76TS 11-19N3210080 19 6” 177 158 132 98

3 ~ 400 V 294 255 24115 11 23,36TS 11-24N3210090 24 6” 223 199 167 124

3 ~ 400 V 392 340 32120 15 31,36TS 11-32N3210100 32 6” 297 265 222 165

3 ~ 400 V 443 385 36525 18,5 38,56TS 11-36N3210110 36 6” 338 303 255 190

Motor

Q

H(m)

(l / min)(m3/ h) 2

50

Eff

. %

0

100

150

200

250

300

350

400

450

500

4 6

100

8 10 12 14 16

10

0

20

30

40

50

60

70

80

90

100

6TS 11-36

6TS 11-32

6TS 11-24

6TS 11-19

6TS 11-16

6TS 11-12

6TS 11-8

6TS 11-46TS 11-3

6TS 11-1

200

Page 149: Electric Pumps Catalogue

6TS - 27

TABLE OF HYDRAULIC PERFORMANCE

152

0

200

12

267

16

333

20

3 ~ 400 V 12,3 11,5 11,12 1,5 46TS 27-1N3210120

In (A) Ql/min

m3/h

0 533

kWHP 32MODELCODE VOLTAGE ( V )

Dis

char

ge

hea

din

met

ers

1

N˚Stages SIZE

4”

400

24

467

28

10,4 9,4 7,8 5,6

3 ~ 400 V 25 23 223 2,2 5,96TS 27-2N3210130 2 4” 21 20 17 14

3 ~ 400 V 37 34 335,5 4 106TS 27-3N3210140 3 4” 31 28 24 19

3 ~ 400 V 37 34 335,5 4 9,36TS 27-3N3210160 3 6” 31 28 24 19

3 ~ 400 V 61 57 557,5 5,5 13,76TS 27-5N3210150 5 4” 52 47 40 31

3 ~ 400 V 61 57 557,5 5,5 12,56TS 27-5N3210170 5 6” 52 47 40 31

3 ~ 400 V 73 68 6610 7,5 166TS 27-6N3210180 6 6” 62 57 49 37

3 ~ 400 V 98 91 8712,5 9,3 20,76TS 27-8N3210190 8 6” 82 75 64 49

3 ~ 400 V 122 113 10915 11 23,36TS 27-10N3210200 10 6” 103 94 81 62

3 ~ 400 V 159 147 14220 15 31,36TS 27-13N3210210 13 6” 134 122 105 81

3 ~ 400 V 207 192 18625 18,5 38,56TS 27-17N3210220 17 6” 175 160 137 106

3 ~ 400 V 244 226 21930 22 45,36TS 27-20N3210230 20 6” 207 188 161 124

329 306 29540 30 -6TS 27-27 *- 27 6” 279 255 220 171

415 385 37250 37 -6TS 27-34 *- 34 6” 351 321 276 215

-

-

Motor

PUMP PERFORMANCE

Q

50

Eff

. %

0

100

150

200

250

300

350

400

450

4 8 12

10

0

20

30

40

50

60

70

80

90

16 20 24 28 32 36

6TS 27-34

6TS 27-27

6TS 27-20

6TS 27-17

6TS 27-13

6TS 27-10

6TS 27-8

6TS 27-66TS 27-5

6TS 27-16TS 27-26TS 27-3

H(m)

200 400 600

* To sell only as separate pump end/motor components

(l / min)(m3/ h)

Page 150: Electric Pumps Catalogue

153

6TS -

22

6TS - 22

TABLE OF HYDRAULIC PERFORMANCE

0

200

12

267

16

333

20

3 ~ 400 V 13,2 11,8 11,11,5 1,1 36TS 22-1N3210280

In (A) Ql/min

m3/h

0 533

kWHP 32MODELCODE VOLTAGE ( V )

Dis

char

ge

hea

din

met

ers

1

N˚Stages SIZE

4”

400

24

467

28

10,3 9,4 8,3 7,0

3 ~ 400 V 26 23 223 2,2 5,96TS 22-2N3210290 2 4” 21 19 16 13

3 ~ 400 V 52 46 435,5 4 106TS 22-4N3210300 4 4” 40 35 31 25

3 ~ 400 V 52 46 435,5 4 9,36TS 22-4N3210320 4 6” 40 35 31 25

3 ~ 400 V 78 68 647,5 5,5 13,76TS 22-6N3210310 6 4” 59 53 46 37

3 ~ 400 V 78 68 647,5 5,5 12,56TS 22-6N3210330 6 6” 59 53 46 37

3 ~ 400 V 104 91 8610 7,5 166TS 22-8N3210340 8 6” 79 71 61 49

3 ~ 400 V 130 114 10712,5 9,3 20,76TS 22-10N3210350 10 6” 99 89 78 64

3 ~ 400 V 168 148 13915 11 23,36TS 22-13N3210360 13 6” 128 115 99 80

3 ~ 400 V 220 193 18220 15 31,36TS 22-17N3210370 17 6” 167 150 130 105

3 ~ 400 V 272 239 22525 18,5 38,56TS 22-21N3210380 21 6” 208 187 163 133

3 ~ 400 V 337 295 27730 22 45,36TS 22-26N3210390 26 6” 256 230 198 161

441 387 36340 30 -6TS 22-34 *- 34 6” 336 302 262 213-

Motor

PUMP PERFORMANCE

Q

50

Eff

. %

0

100

150

200

250

300

350

400

450

4 8 12

10

0

20

30

40

50

60

70

80

90

16 20 24 28 32 36

500 100

6TS 22-34

6TS 22-26

6TS 22-21

6TS 22-17

6TS 22-13

6TS 22-10

6TS 22-8

6TS 22-6

6TS 22-4

6TS 22-26TS 22-1

* To sell only as separate pump end/motor components

H(m)

200 400 600(l / min)(m3/ h)

Page 151: Electric Pumps Catalogue

6TS - 30

TABLE OF HYDRAULIC PERFORMANCE

154

PUMP PERFORMANCE

0

333

20

400

24

467

28

3 ~ 400 V 13,0 11,5 11,02 1,5 46TS 30-1N3210420

In (A) Ql/min

m3/h

0 700

kWHP 42MODELCODE VOLTAGE ( V )

Dis

char

ge

hea

din

met

ers

1

N˚Stages

SIZE

4”

533

32

600

36

10,3 9,5 8,6 6,8

3 ~ 400 V 26 23 213 2,2 5,96TS 30-2N3210430 2 4” 20 18 16 13

3 ~ 400 V 39 34 325,5 4 106TS 30-3N3210440 3 4” 30 28 25 20

3 ~ 400 V 39 34 325,5 4 9,36TS 30-3N3210460 3 6” 30 28 25 20

3 ~ 400 V 64 55 527,5 5,5 13,76TS 30-5N3210450 5 4” 49 44 39 29

3 ~ 400 V 64 55 527,5 5,5 12,56TS 30-5N3210470 5 6” 49 44 39 29

3 ~ 400 V 78 68 6410 7,5 166TS 30-6N3210480 6 6” 60 55 50 40

3 ~ 400 V 90 78 7412,5 9,3 20,76TS 30-7N3210490 7 6” 69 62 55 41

3 ~ 400 V 129 111 10515 11 23,36TS 30-10N3210500 10 6” 97 88 78 58

3 ~ 400 V 167 145 13720 15 31,36TS 30-13N3210510 13 6” 127 116 103 78

3 ~ 400 V 206 179 16925 18,5 38,56TS 30-16N3210520 16 6” 157 144 128 99

3 ~ 400 V 257 222 20930 22 45,36TS 30-20N3210530 20 6” 194 176 155 117

335 290 27440 30 -6TS 30-26 * 26 6” 255 232 205 157

425 367 34650 37 -6TS 30-33 * 33 6” 321 292 258 195

-

-

-

-

Motor

Q

50

Eff

. %

0

100

150

200

250

300

350

400

450

5 10 15

10

0

20

30

40

50

60

70

80

90

20 25 30 35 45 5040

6TS 30-33

6TS 30-26

6TS 30-20

6TS 30-16

6TS 30-13

6TS 30-10

6TS 30-76TS 30-6

6TS 30-5

6TS 30-36TS 30-2

6TS 30-1

H(m)

500

* To sell only as separate pump end/motor components

(l / min)(m3/ h)

250 750

Page 152: Electric Pumps Catalogue

155

6TS -

46

6TS - 46

TABLE OF HYDRAULIC PERFORMANCE

PUMP PERFORMANCE

0

467

28

533

32

600

36

3 ~ 400 V 13,8 11,3 10,72 1,5 46TS 46-1N3210580

In (A) Ql/min

m3/h

0 900

kWHP 54MODELCODE VOLTAGE ( V )

Dis

char

ge

hea

din

met

ers

1

N˚Stages SIZE

4”

700

42

800

48

9,9 8,7 7,4 6,0

3 ~ 400 V 28 23 225,5 4 106TS 46-2N3210590 2 4” 20 18 16 14

3 ~ 400 V 28 23 225,5 4 9,36TS 46-2N3210610 2 6” 20 18 16 14

3 ~ 400 V 41 34 327,5 5,5 13,76TS 46-3N3210600 3 4” 30 27 23 19

3 ~ 400 V 41 34 327,5 5,5 12,56TS 46-3N3210620 3 6” 30 27 23 19

3 ~ 400 V 68 56 5310 7,5 166TS 46-5N3210630 5 6” 50 44 38 32

3 ~ 400 V 82 68 6412,5 9,3 20,76TS 46-6N3210640 6 6” 60 54 47 39

3 ~ 400 V 96 79 7415 11 23,36TS 46-7N3210650 7 6” 70 62 54 45

3 ~ 400 V 136 111 10520 15 31,36TS 46-10N3210660 10 6” 100 91 81 68

3 ~ 400 V 164 135 12825 18,5 38,56TS 46-12N3210670 12 6” 120 107 94 80

3 ~ 400 V 205 167 15730 22 45,36TS 46-15N3210680 15 6” 147 130 111 91

273 223 21140 30 -6TS 46-20 * 20 6” 197 175 152 127

341 280 26450 37 -6TS 46-25 * 25 6” 248 221 192 162

409 336 31860 45 -6TS 46-30 * 30 6” 298 267 233 198

-

-

-

-

-

-

Motor

Q

50

Eff

. %

0

100

150

200

250

300

350

400

450

10

0

20

30

40

50

60

70

80

90

70605040302010

6TS 46-30

6TS 46-25

6TS 46-20

6TS 46-15

6TS 46-126TS 46-10

6TS 46-76TS 46-6

6TS 46-5

6TS 46-36TS 46-2

6TS 46-1

* To sell only as separate pump end/motor components

H(m)

500 1000(l / min)(m3/ h)

Page 153: Electric Pumps Catalogue

6TS - 60

TABLE OF HYDRAULIC PERFORMANCE

156

PUMP PERFORMANCE

0

600

36

700

42

800

48

3 ~ 400 V 14,2 11 10,23 2,2 5,96TS 60-1N3210750

In (A) Ql/min

m3/h

0 1100

kWHP 66MODELCODE≤ VOLTAGE ( V )

Dis

char

ge

hea

din

met

ers

1

N˚Stages SIZE

4”

900

54

1000

60

9,4 8,5 7,8 7,1

3 ~ 400 V 28 22 205,5 4 106TS 60-2N3210760 2 4” 19 17 16 14

3 ~ 400 V 28 22 205,5 4 9,36TS 60-2N3210780 2 6” 19 17 16 14

3 ~ 400 V 43 33 307,5 5,5 13,76TS 60-3N3210770 3 4” 27 24 21 19

3 ~ 400 V 43 33 307,5 5,5 12,56TS 60-3N3210790 3 6” 27 24 21 19

3 ~ 400 V 57 44 4110 7,5 166TS 60-4N3210800 4 6” 37 34 30 26

3 ~ 400 V 71 55 5112,5 9,3 20,76TS 60-5N3210810 5 6” 47 42 38 33

3 ~ 400 V 85 66 6115 11 23,36TS 60-6N3210820 6 6” 56 50 44 38

3 ~ 400 V 114 88 8220 15 31,36TS 60-8N3210830 8 6” 75 68 60 52

3 ~ 400 V 142 110 10225 18,5 38,56TS 60-10N3210840 10 6” 93 84 74 64

3 ~ 400 V 171 132 12230 22 45,36TS 60-12N3210850 12 6” 111 100 88 75

228 176 16240 30 -6TS 60-16 * 16 6” 147 132 116 99

282 214 19750 37 -6TS 60-20 * 20 6” 181 164 146 124

342 266 24760 45 -6TS 60-24 * 24 6” 226 205 184 162

-

-

-

-

-

-

Motor

Q

40

Eff

. %

0

80

120

160

200

240

280

320

360

10

0

20

30

40

50

60

70

80

90

10 20 30 40 50 60 70

6TS 60-24

6TS 60-20

6TS 60-16

6TS 60-12

6TS 60-10

6TS 60-8

6TS 60-66TS 60-5

6TS 60-46TS 60-36TS 60-26TS 60-1

* To sell only as separate pump end/motor components

H(m)

1000(l / min)(m3/ h)

500

Page 154: Electric Pumps Catalogue

157

6TS P

UM

P E

ND

S

6TS PUMP ENDS6" PUMP-ENDS

0

100

6

133

8

167

10MODELCODE SIZE

200

12

233

14

37 32 312 1,56TS 11-3N1058230 4” 29 26 22 16

50 43 413 2,26TS 11-4N1058240 4” 39 35 30 22

98 85 805,5 46TS 11-8N1058250 4” 74 66 56 41

98 85 805,5 46TS 11-8N1058270 6” 74 66 56 41

147 127 1207,5 5,56TS 11-12N1058260 4” 111 99 83 62

147 127 1207,5 5,56TS 11-12N1058280 6” 111 99 83 62

196 170 16110 7,56TS 11-16N1058290 6” 149 133 111 83

233 202 19112,5 9,36TS 11-19N1058300 6” 177 158 132 98

294 255 24115 116TS 11-24N1058310 6” 223 199 167 124

392 340 32120 156TS 11-32N1058320 6” 297 265 222 165

443 385 36525 18,56TS 11-36N1058330 6” 338 303 255 190

4” 9,8 8,8 7,5 5,712,4 11,0 10,51 0,756TS 11-1N1058220

QL/1'

m3/h

0 267

kWHP 16

Dis

char

ge

hea

d in

met

ers

MODELCODE SIZEQ

L/1'

m3/hkWHP

25 23 223 2,26TS 27-2N1058350 4” 21 20 17 14

37 34 335,5 46TS 27-3N1058360 4” 31 28 24 19

37 34 335,5 46TS 27-3N1058380 6” 31 28 24 19

61 57 557,5 5,56TS 27-5N1058370 4” 52 47 40 31

61 57 557,5 5,56TS 27-5N1058390 6” 52 47 40 31

73 68 6610 7,56TS 27-6N1058400 6” 62 57 49 37

98 91 8712,5 9,36TS 27-8N1058410 6” 82 75 64 49

122 113 10915 116TS 27-10N1058420 6” 103 94 81 62

159 147 14220 156TS 27-13N1058430 6” 134 122 105 81

207 192 18625 18,56TS 27-17N1058440 6” 175 160 137 106

244 226 21930 226TS 27-20N1058450 6” 207 188 161 124

329 306 29540 306TS 27-27 *N1058460 6” 279 255 220 171

415 385 37250 376TS 27-34 *N1058470 6” 351 321 276 215

4” 10,4 9,4 7,8 5,612,3 11,5 11,12 1,56TS 27-1N1058340

Required motor

Required motor

0

200

12

267

16

333

20

0 533

32

400

24

467

28

Dis

char

ge

hea

d in

met

ers

* To sell only as separate pump end/motor components

1

N˚Stages

3

4

8

8

12

12

16

19

24

32

36

1

N˚Stages

2

3

3

5

5

6

8

10

13

17

20

27

34

Page 155: Electric Pumps Catalogue

6TS PUMP ENDS

158

6" PUMP-ENDS

MODELCODE SIZEQ

L/1'

m3/hkWHP

Dis

char

ge

hea

d in

met

ers

MODELCODE SIZEQ

L/1'

m3/hkWHP

26 23 223 2,26TS 22-2N1058490 4” 21 19 16 13

52 46 435,5 46TS 22-4N1058500 4” 40 35 31 25

52 46 435,5 46TS 22-4N1058520 6” 40 35 31 25

78 68 647,5 5,56TS 22-6N1058510 4” 59 53 46 37

78 68 647,5 5,56TS 22-6N1058530 6” 59 53 46 37

104 91 8610 7,56TS 22-8N1058540 6” 79 71 61 49

130 114 10712,5 9,36TS 22-10N1058550 6” 99 89 78 64

168 148 13915 116TS 22-13N1058560 6” 128 115 99 80

220 193 18220 156TS 22-17N1058570 6” 167 150 130 105

272 239 22525 18,56TS 22-21N1058580 6” 208 187 163 133

337 295 27730 226TS 22-26N1058590 6” 256 230 198 161

441 387 36340 306TS 22-34 *N1058600 6” 336 302 262 213

4” 10,3 9,4 8,3 7,013,2 11,8 11,11,5 1,16TS 22-1N1058480

26 23 213 2,26TS 30-2N1058620 4” 20 18 16 13

39 34 325,5 46TS 30-3N1058630 4” 30 28 25 20

39 34 325,5 46TS 30-3N1058650 6” 30 28 25 20

64 55 527,5 5,56TS 30-5N1058640 4” 49 44 39 29

64 55 527,5 5,56TS 30-5N1058660 6” 49 44 39 29

78 68 6410 7,56TS 30-6N1058670 6” 60 55 50 40

90 78 7412,5 9,36TS 30-7N1058680 6” 69 62 55 41

129 111 10515 116TS 30-10N1058690 6” 97 88 78 58

167 145 13720 156TS 30-13N1058700 6” 127 116 103 78

206 179 16925 18,56TS 30-16N1058710 6” 157 144 128 99

257 222 20930 226TS 30-20N1058720 6” 194 176 155 117

335 290 27440 306TS 30-26 *N1058730 6” 255 232 205 157

425 367 34650 376TS 30-33 *N1058740 6” 321 292 258 195

4” 10,3 9,5 8,6 6,813,0 11,5 11,02 1,56TS 30-1N1058610

Required motor

Required motor

Dis

char

ge

hea

d in

met

ers

0

200

12

267

16

333

20

0 533

32

400

24

467

28

0

333

20

400

24

467

28

0 700

42

533

32

600

36

* To sell only as separate pump end/motor components

1

N˚Stages

2

4

4

6

6

8

10

13

17

21

26

34

1

N˚Stages

2

3

3

5

5

6

7

10

13

16

20

26

33

Page 156: Electric Pumps Catalogue

159

6TS P

UM

P E

ND

S

6TS PUMP ENDS6" PUMP-ENDS

MODELCODE SIZEQ

L/1'

m3/hkWHP

Dis

char

ge

hea

d in

met

ers

MODELCODE SIZEQ

L/1'

m3/hkWHP

28 23 225,5 46TS 46-2N1058760 4” 20 18 16 14

28 23 225,5 46TS 46-2N1058780 6” 20 18 16 14

41 34 327,5 5,56TS 46-3N1058770 4” 30 27 23 19

41 34 327,5 5,56TS 46-3N1058790 6” 30 27 23 19

68 56 5310 7,56TS 46-5N1058800 6” 50 44 38 32

82 68 6412,5 9,36TS 46-6N1058810 6” 60 54 47 39

96 79 7415 116TS 46-7N1058820 6” 70 62 54 45

136 111 10520 156TS 46-10N1058830 6” 100 91 81 68

164 135 12825 18,56TS 46-12N1058840 6” 120 107 94 80

205 167 15730 226TS 46-15N1058850 6” 147 130 111 91

273 223 21140 306TS 46-20 *N1058860 6” 197 175 152 127

341 280 26450 376TS 46-25 *N1058870 6” 248 221 192 162

409 336 31860 456TS 46-30 *N1058880 6” 298 267 233 198

4” 9,9 8,7 7,4 6,013,8 11,3 10,72 1,56TS 46-1N1058750

28 22 205,5 46TS 60-2N1058900 4” 19 17 16 14

28 22 205,5 46TS 60-2N1058920 6” 19 17 16 14

43 33 307,5 5,56TS 60-3N1058910 4” 27 24 21 19

43 33 307,5 5,56TS 60-3N1058930 6” 27 24 21 19

57 44 4110 7,56TS 60-4N1058940 6” 37 34 30 26

71 55 5112,5 9,36TS 60-5N1058950 6” 47 42 38 33

85 66 6115 116TS 60-6N1058960 6” 56 50 44 38

114 88 8220 156TS 60-8N1058970 6” 75 68 60 52

142 110 10225 18,56TS 60-10N1058980 6” 93 84 74 64

171 132 12230 226TS 60-12N1058990 6” 111 100 88 75

228 176 16240 306TS 60-16 *N1059000 6” 147 132 116 99

282 214 19750 376TS 60-20 *N1059010 6” 181 164 146 124

342 266 24760 456TS 60-24 *N1059020 6” 226 205 184 162

4” 9,4 8,5 7,8 7,114,2 11 10,23 2,26TS 60-1N1058890

Required motor

Required motor

Dis

char

ge

hea

d in

met

ers

0

467

28

533

32

600

36

0 900

54

700

42

800

48

0

600

36

700

42

800

48

0 1100

66

900

54

1000

60

* To sell only as separate pump end/motor components

1

N˚Stages

2

2

3

3

5

6

7

10

12

15

20

25

30

1

N˚Stages

2

2

3

3

4

5

6

8

10

12

16

20

24

Page 157: Electric Pumps Catalogue

TABLE FOR CALCULATING PUMP LENGTH

6TS

160

Pd

DNM

A

CB

MD

MODEL

ATotal

lengthmm.

BMotorlengthmm.

CPumplengthmm.

DNM

PdPump

Diametermm.

Motorweight

Kg.

MDMotor

Diametermm.

Motor

Dim. HP

6TS11 - 1 667 271 396 132 99514”6TS11 - 3 792 327 465 132 129524”6TS11 - 4 854 356 498 132 149534”6TS11 - 8 1218 583 635 132 24955,54”6TS11 - 8 1206 581 625 132 291375,56”6TS11 - 12 1467 698 770 132 38957,54”6TS11 - 12 1374 614 760 132 411377,56”6TS11 - 16 1540 646 894 132 45137106”6TS11 - 19 1675 679 996 132 4813712,56”6TS11 - 24 1877 711 1166 132 51137156”6TS11 - 32 2290 776 1514 132 57137206”6TS11 - 36 2490 842 1649 132 63137256”6TS27 - 1 751 327 424 132 129524”6TS27 - 2 826 356 470 132 149534”6TS27 - 3 1099 583 516 132 24955,54”6TS27 - 3 1089 581 508 132 291375,56”6TS27 - 5 1307 698 610 132 38957,54”6TS27 - 5 1214 614 599 132 411377,56”6TS27 - 6 1294 646 648 132 45137106”6TS27 - 8 1419 679 740 132 4813712,56”6TS27 - 10 1544 711 833 132 51137156”6TS27 - 13 1749 776 973 132 57137206”6TS27 - 17 2000 842 1158 132 63137256”6TS27 - 20 2204 907 1298 132 69137306”6TS27 - 27 2660 1037 1623 132 84137406”6TS27 - 34 3439 1405 2035 132 135137506”6TS22 - 1 807 299 508 132 12951,54”6TS22 - 2 864 356 508 132 149534”6TS22 - 4 1317 583 734 132 24955,54”6TS22 - 4 1305 581 724 132 291375,56”6TS22 - 6 1658 698 960 132 38957,54”6TS22 - 6 1564 614 950 132 411377,56”6TS22 - 8 1822 646 1176 132 45137106”6TS22 - 10 2081 679 1402 132 4813712,56”6TS22 - 13 2454 711 1742 132 51137156”6TS22 - 17 2971 776 2195 132 57137206”6TS22 - 21 3488 842 2647 132 63137256”6TS22 - 26 4117 907 3211 132 69137306”6TS22 - 34 5182 1037 4145 132 84137406”6TS30 - 1 835 327 508 132 129524”6TS30 - 2 864 356 508 132 149534”6TS30 - 3 1203 583 620 132 24955,54”6TS30 - 3 1193 581 612 132 291375,56”6TS30 - 5 1543 698 846 132 38957,54”6TS30 - 5 1453 614 838 132 411377,56”6TS30 - 6 1596 646 950 132 45137106”6TS30 - 7 1741 679 1063 132 4813712,56”6TS30 - 10 2113 711 1402 132 51137156”6TS30 - 13 2519 776 1742 132 57137206”6TS30 - 16 2922 842 2080 132 63137256”6TS30 - 20 3439 907 2532 132 69137306”6TS30 - 26 4247 1037 3211 132 84137406”6TS30 - 33 5436 1405 4031 132 135137506”6TS46 - 1 835 327 508 143 129524”6TS46 - 2 1091 583 508 143 24955,54”6TS46 - 2 1079 581 498 143 291375,56”6TS46 - 3 1317 698 620 143 38957,54”6TS46 - 3 1227 614 612 143 411377,56”6TS46 - 5 1484 646 838 143 45137106”6TS46 - 6 1629 679 950 143 4813712,56”6TS46 - 7 1776 711 1064 143 51137156”6TS46 - 10 2178 776 1402 143 57137206”6TS46 - 12 2470 842 1628 143 63137256”6TS46 - 15 2875 907 1969 143 69137306”6TS46 - 20 3569 1037 2532 143 84137406”6TS46 - 25 4504 1405 3099 143 135137506”6TS46 - 30 5220 1557 3663 143 148137606”6TS60 - 1 864 356 508 143 149534”6TS60 - 2 1091 583 508 143 24955,54”6TS60 - 2 1079 581 498 143 291375,56”6TS60 - 3 1317 698 620 143 38957,54”6TS60 - 3 1227 614 612 143 411377,56”6TS60 - 4 1370 646 724 143 45137106”6TS60 - 5 1517 679 838 143 4813712,56”6TS60 - 6 1661 711 950 143 51137156”6TS60 - 8 1952 776 1176 143 57137206”6TS60 - 10 2244 842 1402 143 63137256”6TS60 - 12 2535 907 1628 143 69137306”6TS60 - 16 3117 1037 2080 143 84137406”6TS60 - 20 3937 1405 2532 143 135137506”6TS60 - 24 4542 1557 2985 143 148137606”

3”

Pumpweight

Kg.

111313161619192325293640111213131616171921252932404811131818232328334151617393111316161818232531414856738811131316162123263338465871831113131616182123283338485868

Page 158: Electric Pumps Catalogue

SA6" MULTISTAGE SUBMERSIBLE PUMPS COMPLETEWITH MOTOR

The SA submerged pumps consist of a multistage pumping unit directly connected toa submersible motor. Especially suitable for pumping from deep 6'' (150mm) Ø wells.Flow rate up to 1100 l/min.

• INTEGRATED CHECK VALVE

162

Motor- 6" Franklin submersible motor- Special resin impregnated sealed stator- Water-cooled thrust bearings and bushes- Approx. 1.5 m extendible power supply cable- Non-polluting water cooling- 6" NEMA flange- Level of protection IP68. Class F insulation- Speed of rotation 2850 rpm- Special mechanical seal with sand guard- Pressure compensation diaphragm- Suitable for continuous use- Electrical control panel on request- Direction of rotation anticlockwise (seen from the delivery end)

Applications- Civil and industrial supply systems- Overhead or surface irrigation- Boosting- Firefighting- Various civil and industrial applications- Mains water supply systems- Heat pumps

Usage limitations- Type of liquid: clean non-aggressive, non-explosive, free of solids- Maximum liquid temperature 30° C- Max. start-ups per hour: 15- Motor protection with thermal relay provided by the user- Maximum quantity of sand present: 40 g/m3

OutletSuction flange

Outer liner

Cable protection filter and trough

Shaft

EN GJS 400 (GS400) Nodular cast iron

Stainless steel

Stainless steel

Stainless steel

EN GJS 400 (GS400) Nodular cast iron

Component Material

DESIGN FEATURES

Impeller Technopolymer/Polycarbonate. SA 615 - SA 625: radial impellers SA 630 - SA 650: semiaxial impellers

Diffuser Noryl GNF 2V

Wear rings Stainless steelBush bearings Bronze/rubber

Page 159: Electric Pumps Catalogue

163

SA

SA 615

TABLE OF HYDRAULIC PERFORMANCE

Ø MOTOR

145

DNM

L

L1

DNM = 3” gas

Pump casing

Ø Motor Electric pump

435 87 791 22478 87 901 27511 87 1056 30625 87 1329 41738 137 1384 58966 137 1677 67

L1(mm) (mm)

L(mm) (kg)

WeightModel

SA 615/4

SA 615/5

SA 615/6

SA 615/9

SA 615/12

SA 615/18

SA 615/4* 62 D8760KKK 3 2,2 3 ~ 400 V

SA 615/5* 78 D8761KKK 4 3 3 ~ 400 V

SA 615/6* 94 D8762KKK 5,5 4,0 3 ~ 400 V

SA 615/9* 140 D8763KKK 7,5 5,5 3 ~ 400 V

SA 615/12 187 D8764KKK 10 7,5 3 ~ 400 V

SA 615/18 281 D8765KKK 15 11 3 ~ 400 V

60

74

89

134

179

268

55

69

82

123

166

250

51

63

75

113

152

231

46

57

68

101

136

210

39

49

58

88

118

180

31

39

46

70

92

138

5,9

7,8

10

13,7

16

23,3

4

5

6

9

12

18

PUMP PERFORMANCE

MODELCODE

MotorPower

kWVOLTAGE Amp. Q

L/1'

m3/h

0 N.Stages

0

300

18

160

9,6

200

12HP

120

7,2

230

13,8

260

15,6

* WITH 4’’ MOTOR

The power curve refers to the brake horse power (BHP) per stage. % indicates the pump hydraulic efficiency

Dis

char

ge h

ead

in m

eter

s

Page 160: Electric Pumps Catalogue

SA 625

164

TABLE OF HYDRAULIC PERFORMANCE

Ø MOTOR

145

DNM

L

L1

DNM = 3” gas

Pumpcasing

Ø Motor Electric pump

L1(mm) (mm)

L(mm) (kg)

WeightModel

511 87 1056 30625 87 1329 41738 137 1384 57966 137 1677 661193 137 1969 751474 137 2316 86

SA 625/4

SA 625/6

SA 625/8

SA 625/12

SA 625/16

SA 625/20

PUMP PERFORMANCE

MODELCODE

Motorpower

kWVOLTAGE Amp. Q

L/1'

m3/h

0N.Stages

0

600

34

300

18

350

21HP

200

12

400

24

500

30

The power curve refers to the brake horse power (BHP) per stage. % indicates the pump hydraulic efficiency

SA 625/4* 61 D8771KKK 5,5 4,0 3 ~ 400 V

SA 625/6* 91 D8772KKK 7,5 5,5 3 ~ 400 V

SA 625/8 122 D8773KKK 10 7,5 3 ~ 400 V

SA 625/12 182 D8774KKK 15 11 3 ~ 400 V

SA 625/16 243 D8775KKK 20 15 3 ~ 400 V

SA 625/20 304 D8776KKK 25 18,5 3 ~ 400 V

53

80

106

159

212

265

48

71

95

143

190

238

44

66

87

131

177

220

40

59

79

119

159

198

28

43

58

88

118

146

17

25

34

50

67

84

10

13,7

16

23,3

31,3

38,5

4

6

8

12

16

20

* WITH 4’’ MOTOR

Dis

char

ge h

ead

in m

eter

s

Page 161: Electric Pumps Catalogue

165

SA

SA 630

TABLE OF HYDRAULIC PERFORMANCE

PUMP PERFORMANCE

MODELCODE

Motorpower

kWVOLTAGE Amp. Q

L/1'

m3/h

0N.Stages

0

800

48

400

24

500

30

Pump casing

ØMotor Electric pump

L1(mm) (mm)

L(mm) (kg)

WeightModel

HP

300

18

600

36

700

42

Ø MOTOR

145

DNM

L

L1

DNM = 3” gas

The power curve refers to the brake horse power (BHP) per stage. % indicates the pump hydraulic efficiency

522 87 1226 39582 137 1228 54762 137 1473 62882 137 1658 701002 137 1844 78

SA 630/4

SA 630/5

SA 630/8

SA 630/10

SA 630/12

SA 630/4* 63 D8782KKK 7,5 5,5 3 ~ 400 V

SA 630/5 78 D8783KKK 10 7,5 3 ~ 400 V

SA 630/8 126 D8784KKK 15 11 3 ~ 400 V

SA 630/10 157 D8785KKK 20 15 3 ~ 400 V

SA 630/12 188 D8786KKK 25 18,5 3 ~ 400 V

57

72

114

143

171

53

67

106

133

160

47

59

94

119

143

40

50

80

101

122

30

37

62

76

92

19

23

37

45

55

13,7

16

23,3

31,3

38,5

4

5

8

10

12

* WITH 4’’ MOTOR

Dis

char

ge h

ead

in m

eter

s

Page 162: Electric Pumps Catalogue

SA 650

166

TABLE OF HYDRAULIC PERFORMANCE

Ø MOTOR

145

DNM

L

L1

DNM = 3” gas

Pump casing

ØMotor Electric pump

L1(mm) (mm)

L(mm) (kg)

WeightModel

PUMP PERFORMANCE

MODELCODE

Motorpower

kWVOLTAGE Amp. Q

L/1'

m3/h

0N.Stages

0

1100

66

700

42

800

48HP

600

36

900

54

1000

60

The power curve refers to the brake horse power (BHP) per stage. % indicates the pump hydraulic efficiency

522 137 1168 53642 137 1353 61822 137 1598 69882 137 1724 761002 137 1909 84

SA 650/4

SA 650/6

SA 650/9

SA 650/10

SA 650/12

SA 650/4 54 D8792KKK 10 7,5 3 ~ 400 V

SA 650/6 81 D8793KKK 15 11 3 ~ 400 V

SA 650/9 122 D8794KKK 20 15 3 ~ 400 V

SA 650/10 135 D8795KKK 25 18,5 3 ~ 400 V

SA 650/12 162 D8796KKK 30 22 3 ~ 400 V

40

59

90

101

120

35

53

80

90

107

31

46

68

77

93

25

37

57

63

75

19

29

44

49

59

13

20

30

33

40

16

23,3

31,3

38,5

45,3

4

6

9

10

12

Dis

char

ge h

ead

in m

eter

s

Page 163: Electric Pumps Catalogue

SA PUMP-ENDS

167

6” SUBMERSIBLE PUMPS

SA

PU

MP

-EN

DS

N1051300

N1051310

N1051320

N1051330

N1051340

N1051350

SA 615/4 *

SA 615/5 *

SA 615/6 *

SA 615/9 *

SA 615/12

SA 615/18

HP 3

HP 4

HP 5,5

HP 7,5

HP 10

HP 15

62 60 55 51 46 39 31

78 74 69 63 57 49 39

94 89 82 75 68 58 46

140 134 123 113 101 88 70

187 179 166 152 136 118 92

281 268 250 231 210 180 138

N1051360

N1051370

N1051380

N1051390

N1051400

N1051410

SA 625/4 *

SA 625/6 *

SA 625/8

SA 625/12

SA 625/16

SA 625/20

HP 5,5

HP 7,5

HP 10

HP 15

HP 20

HP 25

61 53 48 44 40 28 17

91 80 71 66 59 43 25

122 106 95 87 79 58 31

182 159 143 131 119 88 50

243 212 190 177 159 118 67

304 265 238 220 198 146 84

N1051420

N1051430

N1051440

N1051450

N1051460

SA 630/4 *

SA 630/5

SA 630/8

SA 630/10

SA 630/12

HP 7,5

HP 10

HP 15

HP 20

HP 25

63 57 53 47 40 30 19

78 72 67 59 50 37 23

126 114 106 94 80 62 37

157 143 133 119 101 76 45

188 171 160 143 122 92 55

N1051470

N1051480

N1051490

N1051500

N1051510

SA 650/4

SA 650/6

SA 650/9

SA 650/10

SA 650/12

HP 10

HP 15

HP 20

HP 25

HP 30

54 40 35 31 25 19 13

81 59 53 46 37 29 20

122 90 80 68 57 44 30

135 101 90 77 63 49 33

162 120 107 93 75 59 40

* FOR 4’’ MOTOR

CODE MODEL 0Ql/1' 120 160 200 230 260 300 NECESSARYMOTOR

Dhi

scar

ge h

ead

in m

eter

sD

hisc

arge

hea

d in

met

ers

Dhi

scar

ge h

ead

in m

eter

sD

isch

arge

hea

d in

met

ers

0Ql/1' 200 300 350 400 500 600 NECESSARYMOTOR

0Ql/1' 300 400 500 600 700 800 NECESSARYMOTOR

0Ql/1' 600 700 800 900 1000 1100 NECESSARYMOTOR

CODE

CODE

CODE

MODEL

MODEL

MODEL

Page 164: Electric Pumps Catalogue

168

6” MOTORSELECTRIC MOTORS Ø 6” FOR SUBMERSIBLE PUMPSNEMA SPEC WITH PART ELECTRICAL CABLE

Hz

WATER COOLED

221P0930-C

221P0810-C

221P0820-C

221P0940-C

221P0830-C

221P0840-C

221P0880-C

221P0890-C

5,5

7,5

10

12,5

15

20

25

30

4

5,5

7,5

9,3

11

15

18,5

22

3 ~ 400V

3 ~ 400V

3 ~ 400V

3 ~ 400V

3 ~ 400V

3 ~ 400V

3 ~ 400V

3 ~ 400V

50

50

50

50

50

50

50

50

CODEHP kW

POWERVOLTAGE

ZA000420

ZA000430

ZA000440

ZA000450

ZA000460

ZA000470

CABLE 4 x 1

CABLE 4 x 1,5

CABLE 4 x 2,5

CABLE 4 x 4

CABLE 4 x 6

CABLE 4 x 10

NEOPRENE HO7 RNF 4 WIRE CABLE 1 MM2 WIRES

NEOPRENE HO7 RNF 4 WIRE CABLE 1,5 MM2 WIRES

NEOPRENE HO7 RNF 4 WIRE CABLE 2,5 MM2 WIRES

NEOPRENE HO7 RNF 4 WIRE CABLE 4 MM2 WIRES

NEOPRENE HO7 RNF 4 WIRE CABLE 6 MM2 WIRES

NEOPRENE HO7 RNF 4 WIRE CABLE 10 MM2 WIRES

ZA003370

ZA003390

ZA003380

ZA009410

ZA009430

ZA009450

JOINT KIT 2,5

JOINT KIT 6

JOINT KIT 10

JOINT 2,5

JOINT 6

JOINT 10

HEAT-SHRINK SPLICING KIT FOR CABLES UP TO 4 X 2,5

HEAT-SHRINK SPLICING KIT FOR CABLES UP TO 4 X 6

RESIN FILLED SPLICING KIT

HEAT-SHRINK SPLICING JOINT FOR CABLES UP TO 1 - 2,5 mmq

HEAT-SHRINK SPLICING JOINT FOR CABLES UP TO 4 - 6 mmq

RESIN FILLED SPLICING JOINT FOR CABLES UP TO 4 X 10 mmq

CABLES AND JUNCTIONS

Page 165: Electric Pumps Catalogue

169

SELECTION OF ELECTRIC CABLE FOR SUBMERSIBLE PUMPS

MAXIMUM ELECTRIC CABLE LENGTH

Voltage loss 3% - Maximum environmental temperature +30%

MOTOR

KW

Direct starting3 ~ 400 V - 50 Hz

777523384262

0.370.550.751.11.52.234

3515.5

192131967252

MOTOR

kW

1 four - pole cable4 x …mm2

1.5 2.5 4 6 10Cables - L max in m.

2587.5 642109.2 5217611 7014913 601301510518.58922

32021816012088

10384

349256192140

10690

154126

385289210

MOTOR

kW

1 ~ 220 ÷ 240 V - 50 Hz

1 four - pole cable4 x …mm2

Cables - max L in m.

0.37

0.55

0.75

1.1

1.5

2.2

114

77

56

38

6 101.5 2.5 4

47

32

191

128

94

64

75

51

305

205

151

103

113

77

308

226

154

188

128

376

257

3 ~ 230 V - 50 Hz

1 four - pole cable4 x …mm2

Cables - L max in m.

0.75

1.1

1.5

107

76

57

6 101.5 2.5 4

179

127

96

269

191

144

255

192 289

359

383

Page 166: Electric Pumps Catalogue

DRAINAGE AND SEWAGE PUMPS

Page 167: Electric Pumps Catalogue

172

DPSUBMERSIBLE PUMPS FOR DRAINING CLEAR WATER

The DP series submersible pumps for clear water have been designed for domesticapplications as drainage of seepage water, pumping of water from wells, water depositsand collection tanks. Equipped with 25-32 Ø rubber holder. The float level switchenables the pump to work automatically.

• COMPACT AND HANDY• EASY TO CARRY IN CASE OF EMERGENCY

Motor- Single-phase asynchronous motor with capacitor permanently activated and thermal protection built into the motor winding- Level of protection IP68- Class F insulation- Completely insulated cable connection chamber- Speed of rotation 2850 rpm

Applications- Drainage of seepage water, pumping of rain water from a grating or drain- Draining of environments, tanks and wells

Usage limitations- Type of liquid: clear water- Maximum liquid temperature 40°C- Maximum submersion under the water level 7 m- Minimum drainage level 10 mm- Free clearance of solids 6 mm

Component

Pump body

Impeller

Motor shaft

Seal

Material

Technopolymer

Technopolymer

X 12 CrS 13 (AISI 416) Stainless steelwith a ceramic facing at the points of seal wear

DESIGN FEATURES

Power cable 10 m H05 RN-F with plug

123 Motor casing X 8 CrNi 18-10 (AISI 304) Stainless steel

4

5

Fixed double NBR 70 rubber seal.Oil chamber for seal lubrication.6

1

2

3

5

6

Page 168: Electric Pumps Catalogue

173

DP

TABLE OF HYDRAULIC PERFORMANCE

DP

0

25

1,5

50

3

100

6

Hm

L / 1'm3/ h

Q

* Start and stop level refers to the version equipped with floating switch The minimum drainage level refers to the manual version

40

2,4

2

20

1,2

60

3,6

80

4,8

100

6

120

7,2

140

8,4

160

9,6

4

6

8

PUMP PERFORMANCE

180/7

DP 130/6 AUT 236 3,910 330 256

TABLE OF SIZES AND WEIGHTS

Model

Dimensions mm.

A

Weight

C kgB E

DP 180/7 AUT 236 4,210 330 256

150

D

150

MODELCODE

Absorbedpower

kWHPVOLTAGE Amp. µF. Q

L/1'

m3/h

0 150

9

DP 180/7 AUT* 1 ~ 230 V0,5 0,37 6,2 5,2 3,27 1,11,6 10 N1041180

N1041190 DP 130/6

*Automatic version equipped with float switch

DP 130/6 AUT*1 ~ 230 V0,4 0,3 6 4,5 1,771,4 6,3

N1041170

Dis

char

gehe

adin

met

ers

Page 169: Electric Pumps Catalogue

SIMER PUMPSSUBMERSIBLE PUMPS FOR DRAINING CLEAR WATER

The SIMO submersible pumps for clear water have been designed for drainage ofseepage water, pumping of water from sump pits, water deposits and collection tanks.

SIMER SIMO• EXCELLENT FOR INDUSTRIAL DRAINAGE• MINIMUM DRAINAGE LEVEL 3 mm

• EQUIPPED WITH 13-19-25 Ø ADAPTABLE CONNECTOR

Motor– Single-phase asynchronous oil cooled motor with capacitor permanently activated and thermal protection built into the motor winding– Level of protection IPX8– Class F insulation– Speed rotation 2850 rpm

Applications– Drainage of seepage water, pumping of rain water from grating or drain– Emptying of water deposits, collection tanks and wells.

Usage limitations– Type of liquid: clear water– Maximum liquid temperature 50° C– Maximum submersion under the water level 2 m– Minimum drainage level 3 mm– Minimum priming level 20 mm

SIMER P3010• 12 VOLT BATTERY MOTOR• CABLE WITH COPPER EYELETS FOR HOOKUP TO AUTO OR MARINE BATTERY• MINIMUM DRAINAGE LEVEL 3 mm

Motor– Syncronous electric motor, 12 V DC 21 Amp.– Level of protection IP X8

Applications– Drainage of seepage water, pumping of rain water from grating or drain– Create streams and waterfalls for gardens– Residential application– Marine application

Usage limitations– Type of liquid: clear water– Maximum liquid temperature 50 °C– Minimum liquid temperature 1.7 °C– Minimum drainage level 3 mm– 16 cm openings tting– 12 volt, 21 amp DC battery powered motor

174

Component

Pump body

Impeller

Motor shaft

SIMER SIMODie cast aluminium

Die cast zinc

DESIGN FEATURES

Power cord H07RN-F 10m cable(rapid clutch)

Motor casing Die cast aluminium

Meccanical seal Graphite / Ceramic

Gaskets / O-ring NBR

Made in U.S.A.

Made in U.S.A.

X 12 CrS 13 (AISI 416)Stainless Steel

Technopolymer GE VALOX 357

CELCON Acetalcopolymer GB 254

PVC SJTOW 3m cable(rapid clutch)

Alluminium ASTM 360

Graphite / Ceramic

NBR

Stainless Steel

P3010 GEYSERMaterial

Page 170: Electric Pumps Catalogue

SIM

ER

PU

MP

S

SIMER PUMPS

SIMER P3010 12 V0,35 0,25 7,7 5,8 4,89,1P1041900 *

75

4,5

0

1,5

SIMER P3010 3150 1” 1/4 M180

* Performances depend on battery level

175

PUMP PERFORMANCE

MODELCODE

Absorbedpower

kWHPVOLTAGE Q

L/1'

m3/h

4

Dischargehead

in meters

0,2

21

1,3

40

2,4

55

3,3

SIMER SIMO PUMP 1 ~ 230 V0,55 0,4 4,6 3 1,56,1OD6601G-02

SIMER SIMO PUMP 5,3160 1” 1/4 F

TABLE OF SIZES AND WEIGHTS

Model

Dimensions mm. Weight

D kgDNM

185

H

TABLE OF HYDRAULIC PERFORMANCE

Hm

L / 1'm3/ h

Q

2

10

0,6

20

0,6

30

0,6

40

0,6

50

0,6

60

0,6

70

0,6

80

0,6

90

0,6

4

6

8

10

SIMER SIMO PUMP

SIMER P3010

H

DNM

D

Page 171: Electric Pumps Catalogue

176

DPCSUBMERSIBLE PUMP FOR DRAINING CLEAR WATER

The DPC pump has been designed for domestic applications as drainage of seepagewater, pumping of water from sump pits, water deposits or collection tanks. Equippedwith rubber holder for 3/4 or 25-32 Ø hoses and check valve.

• COMPACT• INTEGRATED FLOAT SWITCH• MANUAL-AUTOMATIC SELECTOR• MINIMUM DRAINAGE LEVEL 3mm

Motor- Single-phase asynchronous motor with capacitor permanently activated and thermal protection built into the motor winding- Level of protection IP68- Class F insulation- Completely insulated cable connection chamber- Speed of rotation 2850 rpm’

Applications- Drainage of seepage water, pumping of rain water from a grating or drain- Draining of environments, tanks and wells

Usage limitations- Type of liquid: clear water- Maximum liquid temperature 40°C- Maximum submersion under the water level 7 m- Minimum drainage level 3 mm (man.), 30 mm (aut.)- Free clearance of solids 5 mm

6

2

3

7

1

54

8

Component

Pump body

Suction base

Motor casing

Mechanical seal

Material

Technopolymer

Technopolymer

X 8 CrNi 18-10 (AISI 304) Stainless steel

DESIGN FEATURES

Power cable 10 m H05 RN-F With schuko plug

123 Impeller Technopolymer

45

Graphite7

Motor shaft X 8 CrNi 18-9 (AISI 304) Stainless steel6

Counterface Ceramic8Secondary seal NBR rubber9

Oil chamber for seal lubrication

Page 172: Electric Pumps Catalogue

177

DP

C

TABLE OF HYDRAULIC PERFORMANCE

DPC

PUMP PERFORMANCE

MODELCODE

Absorbedpower

kWHPVOLTAGE Amp. µF. Q

L/1'

m3/h

0 160

9,60

50

3

100

6

120

7,2

DPC 200/10 1 ~ 230 V0,87 0,65 8 6 4,610 2,22,9 8 N1080110

DPC 200/10 273 5,6148 200 1" 1/497 63170

TABLE OF SIZES AND WEIGHTS

Model

Dimensions mm.

A

Weight

C kgB DNMFED

Hm

L / 1'm3/ h

Q

200/10

40

2,4

2

20

1,2

60

3,6

80

4,8

100

6

120

7,2

140

8,4

160

9,6

4

6

8

10

12

Dischargehead

in meters

Page 173: Electric Pumps Catalogue

DRENOXSUBMERSIBLE SUMP PUMPS FOR DRAININGCLEAR WATER

The DRENOX series pumps are built entirely in AISI 304 stainless steel. Cooling of themotor is via a heat exchange chamber that allows the machine to work for long periodswhen not completely submerged.Equipped with Ø 32 mm hose adapter.Automatic version equipped with float switch.

178

Motor- Dry motor with stainless steel casing- Level of protection IP68- Class F insulation- Single phase power supply with capacitor permanently activated and thermal protection built into the motor winding- Three phase power supply with external protection provided by the user- Completely insulated cable connection chamber- Self-lubricating ball bearings- Speed of rotation 2850 rpm

Applications- Drainage of seepage water, pumping of rain water, from a grating or drain, pumping of domestic waste water, drainage of environments, bathing and swimming pools, industrial applications- Fountains and water features- Surface irrigation

Usage limitations- Type of liquid: partially effluent and dirty clear water, non-aggressive liquids- Maximum liquid temperature 40°C- Maximum submersion under the water level 7m- Minimum drainage level 3 mm for model 80/7, 35 mm for the other models (manual version)- Free clearance of solids 3 mm for models 80/7,

6 mm for the other models

Component

Pump body

Suction grid

Motor shaft

Seal

Material

X 5 CrNi 1810 (AISI 304) Stainless steel

X 5 CrNi 1810 (AISI 304) Stainless steel

Stainless steel shaft with a ceramicfacing at the points of seal wear

Fixed double NBR 70 rubber seal with special sandguard V-ring. Oil chamber for seal lubrication.

DESIGN FEATURES

Power cable 10 m H07 RN-F with plug

123 Impeller X 5 CrNi 1810 (AISI 304) Cast stainless steel

4

5

6

4

1

5

6

3

2

Page 174: Electric Pumps Catalogue

179

DR

EN

OX

TABLE OF HYDRAULIC PERFORMANCE

DRENOX

L / 1'm3/ h

Q 200 50 300

3 12 18

Hm

10

6

150

9

2

8

100

6

250

15

12

4

350/12

250/10

160/8

80/7

PUMP PERFORMANCE

MODELCODE

Absorbedpower

kWVOLTAGE Amp. µF. Q

L/1'

m3/h

10Nominalpower

HP 0,6

80

4,8

120

7,2

40

2,4

60

3,6kW HP

160

9,6

240

14,4

300

18

1 ~ 220 ÷ 240 V DRENOX 80/7 DRENOX 80/7 AUT

N1031090 N1031100

0,4 0,30,3 0,2

1 ~ 220 ÷ 240 V DRENOX 160/8 DRENOX 160/8 AUT

N1031020 N1031060

0,75 0,550,55 0,40 7 5,8 5 4,1 2,2

1 ~ 220 ÷ 240 V N1031030 N1031070

1,2 0,90,75 0,55

1 ~ 220 ÷ 240 V DRENOX 350/12 DRENOX 350/12 AUT

N1031040 N1031080

1,6 1,21,1 0,8 10,5 10 9,5 9 7,7

3 ~ 400 V DRENOX 350/12 T N1031110 1,6 1,21,1 0,8

DRENOX 250/10 DRENOX 250/10 AUT

9,4 8,5 7,6 7,2 5,1 4,0

6,5 3,4 1

5,4 3,3 1,8

10,5 10 9,5 9 7,7 6,5 3,4 1

1,3

2,4

4,5

5,1

2

6,3

8

10

16

1

Automatic version equipped with float switch

Dis

charg

ehead

in m

ete

rs

Page 175: Electric Pumps Catalogue

DRENOX

180

TABLE OF SIZES AND WEIGHTS

Model

Dimensions mm.

A

Weight

Ø C kgB

Free bore

DNM

DRENOX 80/7 231 5,761 177 ø 3 1" 1/4

Start level Stop levelMinimumdrainage level

250 1003

F* G*E*

* Start and stop level refers to the version equipped with floating switch The minimum drainage level refers to the manual version

D

182

DRENOX 80/7

Page 176: Electric Pumps Catalogue

181

DR

EN

OX

DRENOX

TABLE OF SIZES AND WEIGHTS

Free bore Model

Dimensions mm.

A

Weight

Ø C kgB DNMF* G*E*

* Start and stop level refers to the version equipped with floating switch The minimum drainage level refers to the manual version

D

DRENOX 250/10

DRENOX 160/8 300

338

6,5

7

94

94

177

177

ø 6

ø 6

1" 1/4

1" 1/4

DRENOX 350/12 338 8,594 177 ø 6 1" 1/4

320

351

351

107

111

111

35

35

35

182

182

182

DRENOX 160/8 - 250/10 - 350/12

Start level Stop levelMinimumdrainage level

Page 177: Electric Pumps Catalogue

DPVSUBMERSIBLE PUMP FOR DRAINING DIRTY WATER

The DPV pump has been designed for domestic applications, to move waste waterwith solids of a maximum dimension of 25 mm and for the emptying of dirty watercollection tanks. It is equipped with Ø 32 rubber holder. Automatic version equippedwith float switch.

• COMPACT AND HANDY• EASY TO CARRY IN CASE OF EMERGENCY

Motor- Single-phase asynchronous motor with capacitor permanently activated and thermal protection built into the motor winding- Level of protection IP68- Class F insulation- Completely insulated cable connection chamber- Speed of rotation 2850 rpm

Applications- Drainage of domestic dirty water- Draining of environments, tanks and wells

Usage limitations- Type of liquid: dirty water with solids- Maximum liquid temperature 40°C- Maximum submersion under the water level 7 m- Minimum drainage level 35 mm- Free clearance of solids 25 mm

182

Component

Pump casing

Impeller

Motor shaft

Seal

Material

Technopolymer

Technopolymer

X 12 CrS 13 (AISI 416) stainless steelwith a ceramic facing at the points of seal wear

DESIGN FEATURES

Power cable 10 m H05 RN-F with plug

123 Motor casing X 8 CrNi 18-10 (AISI 304) Stainless steel

4

5

Fixed double NBR 70 rubber seal.Oil chamber for seal lubrication6

1

2

35

6

Page 178: Electric Pumps Catalogue

DP

V

TABLE OF HYDRAULIC PERFORMANCE

DPV

183

DPV 160/6 AUT* N2101110

* Start and stop level refers to the version equipped with floating switch The minimum drainage level refers to the manual version

* Automatic version equipped with float switch

160/6

Hm

L / 1'm3/ h

Q40

2,4

20

1,2

60

3,6

80

4,8

100

6

120

7,2

140

8,4

160

9,6

2

4

6

PUMP PERFORMANCE

MODELCODE

Absorbedpower

kWHPVOLTAGE Amp. µF. Q

L/1'

m3/h

0 100

60

20

1,2

60

3,6

80

4,8

DPV 160/61 ~ 230 V0,56 0,41 5,4 4,2 3,36,5 2,41,9 10

N2101120

DPV 160/6 AUT 284 4,235 330 150

TABLE OF SIZES AND WEIGHTS

Model

Dimensions mm.

A

Weight

C kgB D

304

E

Dischargehead

in meters

Page 179: Electric Pumps Catalogue

OMNIASUBMERSIBLE SUMP PUMPS FOR DIRTY WATER

The OMNIA series pumps are made entirely of AISI 304 stainless steel. Cooling of themotor is via a heat exchange chamber that allows the machine to work for long periodswhen not completely submerged. Equipped with Ø 32mm hose adapter.Automatic version equipped with float switch.

184

Motor- Dry motor with stainless steel casing- Level of protection IP68- Class F insulation- Single phase power supply with capacitor permanently activated- Thermal protection built into the motor winding- Completely insulated cable connection chamber- Self-lubricating ball bearings- Speed of rotation 2850 rpm

Applications- Pumping of domestic waste water, draining of environments, bathing and swimming pools, industrial applications- Fountains and water features- Surface irrigation

Usage limitations- Type of liquid: waste water with solids- Maximum liquid temperature 40°C- Maximum submersion under the water level 7m- Minimum drainage level 35 mm (manual)- Free clearance of solids 20 mm

Component

Pump body

Suction base

Motor shaft

Seal

Outlet

Material

X 5 CrNi 1810 (AISI 304) Stainless steel

X 5 CrNi 1810 (AISI 304) Stainless steel

X 12 CrNiS 1809 (AISI 416) Stainless steel

Fixed double NBR 70 rubber lip seal.Oil chamber for seal lubrication.

DESIGN FEATURES

Power cable 10 m H07 RN-F with plug

123 Impeller X 5 CrNi 1810 (AISI 304) Stainless steel

45

1" 1/4 gas male threaded

6

7

1

2

3

4

5

6

7

Page 180: Electric Pumps Catalogue

185

OM

NIA

TABLE OF HYDRAULIC PERFORMANCE

OMNIA

50

4

6

8

100 150 200

12963

200/8160/7

80/5

2

L / 1'm3/ h

Q

PUMP PERFORMANCE

MODELCODE

Absorbedpower

kWVOLTAGE Amp. µF. Q

L/1'

m3/h

10Nominalpower

HP 0,6

100

6

140

8,4

40

2,4

70

4,2kW HP

200

12

0,4 0,3 2,7 10,3 0,2

0,7 0,5 5,5 4 2,8 10,5 0,37

4,1

7

1 0,75 6,3 5,4 4,1 2,70,7 0,5 7,8 0,5

OMNIA 80/5

OMNIA 160/7

OMNIA 200/8

1 ~ 220 ÷ 240 V

1 ~ 220 ÷ 240 V

1 ~ 220 ÷ 240 V

1,4

2,5

3,2

8

8

8

OMNIA 80/5 AUT

OMNIA 160/7 AUT

OMNIA 200/8 AUT

N2081090

N2081110

N2081100

N2081070

N2081020

N2081030 Dis

char

ge h

ead

in m

eter

s

Page 181: Electric Pumps Catalogue

OMNIA

186

TABLE OF SIZES AND WEIGHTS

Model

Dimensions mm.

A

Weight

Ø C kgB

Free bore

DNM

Start level Stop levelMinimumdrainage level

F* G*E*

* Start and stop level refer to the version equipped with float switch. The minimum drainage level refers to manual working.

D

OMNIA 200/8

OMNIA 160/7

OMNIA 80/5 264

300

338

6,1

7

8,5

94

94

94

177

177

177

Ø 20

Ø 20

Ø 20

1" 1/4

1" 1/4

1" 1/4

250

320

351

100

107

111

35

35

35

182

182

182

Page 182: Electric Pumps Catalogue

PRIOXSUBMERSIBLE EFFLUENT VORTEX PUMPS FORDIRTY WATER

The PRIOX series pumps are made entirely of AISI 304 stainless steel. They workcompletely submerged in the pumped liquid that cools the motor externally. Manufacturedon the vortex operating principle with the impeller set back.Automatic version equipped with float switch.

187

Motor— Dry motor— Level of protection IP 68— Class F insulation— Single phase power supply with capacitor permanently activated and thermal protection built into the motor winding— Three phase power supply with external protection under care of the user (control panel on request)— Completely insulated cable connection chamber— Self-lubricating ball bearings— Speed of rotation 2850 rpm

Applications— All applications of pumping and draining effluent, civil and industrial sewage with suspended solids— Pumping stations with one or more pumps for civil and industrial plants

Usage limitations— Type of liquid: waste water and sewage with solids— Maximum liquid temperature 40¡C.— Maximun submersion under the water level 7m— Minimum drainage level 60 mm (manual version)— Free clearance of solids: 40 mm 50mm (PRIOX 600/13 - PRIOX 800/18)

1

2

3

6

7

8

9

4

1011

5

Component

Pump body

Suction base

Cover

Power cable

Motor shaft

Material

X 5 CrNi 1810 (AISI 304) Stainless steel

X 5 CrNi 1810 (AISI 304) Stainless steel

Cast stainless steel (Priox 800/18)

10 m H07 RN-F with plug

DESIGN FEATURES

Outlet Threaded

123 Impeller X 5 CrNi 1810 (AISI 304) Cast stainless steel

45

6

7

Silicum carbideCounterface

NBR rubber lip seal

8

Secondary seal

9 Oil chamber for seal lubrication

10

V-ring sand guard NBR rubber11

Mechanical seal Silicum carbide

X 12 CrNiS 1809 (AISI 416) Stainless steel

Page 183: Electric Pumps Catalogue

188

TABLE OF HYDRAULIC PERFORMANCE

PRIOX

PUMP PERFORMANCE

kWAmp. F. Q

L/1’

m3/h

50

HP 3

200

12

250

15

100

6

150

9kW HP

300

18

400

24

550

33

500

30

600

36

650

39

PRIOX 420/11 T

PRIOX 460/13 T

N2110080

N2110070

1 ~ 230 V PRIOX 300/9 M PRIOX 300/9 M AUT

N2110040 N2110050

1 ~ 230 V N2110020 N2110030

1 ~ 230 V PRIOX 460/13 M PRIOX 460/13 M AUT

N2110000 N2110010 10,8 9,8 8,5 7 5,5

3 ~ 400 V PRIOX 600/13 T N2110060

PRIOX 420/11 M PRIOX 420/11 M AUT

2

4,1

6

7,5

3

12,5

20

20

6,4 5 3,8 2,3

9 7,8 6,3 5 3,8

1

1

12,2 11,3 10,3 9,3 8 5,5 3

3 ~ 400 V

3 ~ 400 V 2,3

2,7

0,8

1,2

1,2

1,5

1,4

1,6

0,6

0,9

0,9

1,1

1

1,2

1,2

1,8

1,8

2,2

2

2,4

0,9

1,3

1,3

1,6

1,45

1,8

11,8

7,7

10

12,8 1,8

PRIOX 250/8 M PRIOX 250/8 M AUT

PRIOX 300/9 T

1 ~ 230 V 3,6 140,75 0,55 1,1 0,8 5,2 3,4 2,0 0,26,5

3 ~ 400 V 1,550,8 0,6 1,2 0,9 6,4 5 3,8 2,3 17,7

N2110100 N2110110

N2110090

3 ~ 400 V PRIOX 800/18 T N2110130 5,5 16,5 15,6 14,7 13,7 12,7 10,5 83,2 2,4 4 3 17,3 6,7 5,4 4

CODE MODEL

Nominalpower

Absorbedpower

VOLTAGE

500100 6002006 12 30 36

30018

40024

14

12

6

4

2

8

10

m3/ hL / 1’Q

Hm

16

18

20

800/18

600/13460/13420/11300/9250/8

70042

Dis

char

ge h

ead

in m

eter

s

Page 184: Electric Pumps Catalogue

PRIOX

189

PR

IOX

TABLE OF SIZES AND WEIGHTS

Model

Dimensions mm.

A

Weight

fl C kgB

Freebore

DNM

Startlevel

Stoplevel

Minimumdrainage

levelF* G*E*D

PRIOX 460/13

PRIOX 420/11

PRIOX 300/9 420

450

450

9,6

11,2

11,7

122,5 235 fl 40

fl 40

fl 40

2"

2"

2"

PRIOX 600/13 450 12,6fl 50 2"

122,5

122,5

122,5

235

235

235

PRIOX 250/8 420 9,4122,5 235 fl 40 1"1/2

63

63

63

63

63

290

320

320

290

550

580

580

550

241

241

241

241

241

PRIOX 800/18 T 485,5 122,5 235 63241 20,2fl 50 2"

320580

* Start and stop level refer to the version equipped with float switch. The minimum drainage level refers to manual working.

Page 185: Electric Pumps Catalogue

MINIVORT PSUBMERSIBLE SEWAGE PUMPS WITH VORTEX IMPELLER

The MINIVORT P pumps are made entirely of cast iron and designed for continuoususe in fixed installations. Manufactured on the vortex operating principle with theimpeller set back.Strong and resistant.

190

Motor- Dry motor- Level of protection IP68- Class F insulation- Single phase power supply with capacitor permanently activated and thermal protection built into the motor winding- Three phase power supply with external protection provided by the user- Self-lubricating ball bearings- Speed of rotation 2850 rpm- Four pole 1450 rpm (P2) motor (P4).

Applications- Pumping and draining effluent; civil and industrial sewage with suspended solids- Draining of cesspits, cesspools, handling of effluent- Pumping stations with one or more pumps for civil and industrial plants

Usage limitations- Type of liquid: waste water and sewage- Maximum liquid temperature 40¡C- Maximum submersion under the water level 7m- Minimum drainage level 45mm (manual version)- Free clearance of solids 52 mm

Impeller

Pump body

Motor shaft

Mechanical sealCounterface

EN GJL 200 (ex G20) Grey cast iron

X 12 CrNiS 1809 (AISI 416) Stainless steel

Oil chamber for seal lubricationCeramic

Motor casing EN GJL 200 (ex G20) Grey cast iron

Base EN GJL 200 (ex G20) Grey cast iron

EN GJL 200 (ex G20) Grey cast iron

Component Material

DESIGN FEATURES

Design features- Automatic single phase version with float switch and sealed electric panel including capacitor, thermal protection and manual/automatic switch. 10 m H07 RN-F power supply cable- Three phase version, 10 m H07 RN-F power supply cable- Flanged outlet connection, with square threaded counterflange - 2" female

Lip seal NBR 70 rubber

Page 186: Electric Pumps Catalogue

191

MIN

IVO

RT P

TABLE OF HYDRAULIC PERFORMANCE

MINIVORT P

TABLE OF SIZES AND WEIGHTS

ModelDimensions mm.

A

Weight

C kg

PUMP PERFORMANCE

MODELCODE

Absorbedpower

kWVOLTAGE Amp. F. Q

L/1’

m3/h

50Nominalpower

HP 3

300

18

400

24

100

6

200

12kW HP

500

30

B

A D

C

DN

M

L / 1’m3/ h

Q

Hm

500100 6002006 12 30 36

30018

40024

70042

14

12

6

4

2

8

10P2 - 2

P2 - 1,5P2 - 1

1 ~ 220 240 V1 ~ 220 240 V

3 ~ 400 V

MINIVORT P2 - 1 M MINIVORT P2 - 1 M AUT MINIVORT P2 - 1 T

N2041010 N2041020 N2041030

2 1,5 6 5,41 0,75

MINIVORT P2 - 1,5 M MINIVORT P2 - 1,5 M AUT MINIVORT P2 - 1,5 T

N2042010 N2042020 N2042030

2,2 1,6 8,3 7,51,5 1,1

MINIVORT P2 - 2 M MINIVORT P2 - 2 M AUT MINIVORT P2 - 2 T

N2043010 N2043020 N2043030

3 2,2 12,1 11,32 1,5

1 ~ 220 240 V1 ~ 220 240 V

3 ~ 400 V1 ~ 220 240 V1 ~ 220 240 V

3 ~ 400 V

4,1 3 1

6,1 4,6 2,8 1

9,8 8 6 3,7

6,56,52,3

77

2,79,89,83,2

2020

2525

3535

P4 - 1

B D DNM

MINIVORT P2 - 2

MINIVORT P2 - 1,5

MINIVORT P2 - 1 45

45

45

27

27

28

440

440

440

85

85

85

235

235

235

2"

2"

2"

MINIVORT P4 - 1 45 27440 85 235 2"

MINIVORT P4 - 1 M MINIVORT P4 - 1 M AUT MINIVORT P4 - 1 T

N2044010 N2044020 N2044030

1,7 1,25 5 4,61 0,751 ~ 220 240 V1 ~ 220 240 V

3 ~ 400 V3,3 2,2

5,55,52,3

2525

MINIVORT P2 : 2 poles motor 2850 rpmMINIVORT P4 : 4 poles motor 1450 rpm

Dis

char

ge h

ead

in m

eter

s

Page 187: Electric Pumps Catalogue

MINIVORT PPSUBMERSIBLE SEWAGE PUMPS WITH VORTEX IMPELLER

The MINIVORT PP pumps are made entirely of cast iron and designed for continuoususe in fixed installations. Manufactured on the vortex operating principle with theimpeller set back.

192

Motor- Dry motor- Level of protection IP68- Class F insulation- Single phase power supply with capacitor permanently activated and thermal protection built into the motor winding- Three phase power supply with external protection provided by the user- Self-lubricating ball bearings- Speed of rotation 2850 rpm

Applications- Pumping and draining effluent; civil and industrial sewage with suspended solids- Draining of cesspits, cesspools, handling of effluent- Pumping stations with one or more pumps for civil and industrial plants- On request, connecting foot to make installations and maintenance easier

Usage limitations- Type of liquid: waste water and sewage- Maximum liquid temperature 40¡C- Maximum submersion under the water level 7m- Minimum drainage level 72mm (manual version)- Free clearance of solids 58 mm

Design features- Automatic single phase version with float switch and sealed electric panel including capacitor, thermal protection and manual/automatic switch. 10 m H07 RN-F power supply cable- Three phase version, 10 m H07 RN-F power supply cable- Single phase version with panel complete with capacitor and 10 m H07 RN-F power supply cable- Flanged outlet connection, with square threaded counterflange - 2" female

Impeller

Pump casing

Motor shaft

Mechanical sealCounterface

EN GJL 200 (ex G20) Grey cast iron

X 12 CrNiS 1809 (AISI 416) Stainless steel

Oil chamber for seal lubricationCeramic

Motor casing EN GJL 200 (ex G20) Grey cast iron

Base EN GJL 200 (ex G20) Grey cast iron

EN GJL 200 (ex G20) Grey cast iron

Power cable 10 m H07 RN-F

Component Material

DESIGN FEATURES

12

3

45

6

78

1

2

3

4

6

5

7

8

OptionalCast iron connecting foot( cod. N2054010 )

Lip seal NBR 70 rubber-

Graphite

Page 188: Electric Pumps Catalogue

193

MIN

IVO

RT P

P

TABLE OF HYDRAULIC PERFORMANCE

MINIVORT PP

TABLE OF SIZES AND WEIGHTS

PUMP PERFORMANCE

MODELCODE

Absorbedpower

kWVOLTAGE Amp. F. Q

L/1’

m3/h

100Nominalpower

HP 6

400

24

600

36

200

12

300

18kW HP

800

48

B

A

D

CD

NM

L / 1’m3/ h

Q

Hm

PP2 - 1

500100 6002006

300 400 700

12

10

8

6

2

48 54800 900

4

12 30 3618 24 42

PP2 - 1,5

PP2 - 2

MINIVORT PP2 - 2

MINIVORT PP2 - 1,5

MINIVORT PP2 - 1 72

72

72

30

31

33

475

475

475

115

115

115

325

325

325

2 1/2"

2 1/2"

2 1/2"

1 ~ 220 240 V1 ~ 220 240 V

3 ~ 400 V

MINIVORT PP2 - 1 M MINIVORT PP2 - 1 M AUT MINIVORT PP2 - 1 T

N2051010 N2051020 N2051030

2 1,5 5 41 0,75

MINIVORT PP2 - 1,5 M MINIVORT PP2 - 1,5 M AUT MINIVORT PP2 - 1,5 T

N2052010 N2052020 N2052030

1,8 6,7 5,7

MINIVORT PP2 - 2 M MINIVORT PP2 - 2 M AUT MINIVORT PP2 - 2 T

N2053010 N2053020 N2053030

3 2,2 10 9,32 1,5

1 ~ 220 240 V1 ~ 220 240 V

3 ~ 400 V1 ~ 220 240 V1 ~ 220 240 V

3 ~ 400 V

3

4,6 3,3 1

8,2 7 4,2 1

6,26,22,38,28,23

9,89,83,5

2020

2525

3535

1,6

1,6 1,2 2,5

ModelDimensions mm.

A

Weight

C kgB D DNM

Dis

char

ge h

ead

in m

eter

s

Page 189: Electric Pumps Catalogue

FG

194

SUBMERSIBLE PUMPS FOR WASTE WATER

Identification name

AUT2M1,550T

AUT Automatic with float switch

246

FG

Nß of poles

MT

Single-phaseThree-phase

1,5 - 30 Rated power in HP

50 -150 DN outlet in mm

TVC

Cutter plate impellerVortex impellerSingle channel impeller

FG Series

MODEL QL/1’

m3/h

0

HP 0kW

Dis

char

ge h

ead

in m

eter

s

15,2FGT 50 1,5 M2

FGT 50 1,5 M2 AUT

FGT 50 2 T2FGT 50 2,5 T2

1,5

1,5

22,5

NominalPower

1,1

1,1

1,51,8

25

1,5

50

3

75

4,5

100

6

125

7,5

150

9

175

10,5

185,5

11,1

200

12

212,5

12,7

225

13,5

250

15

275

16,5

300

18

325

19,5

15,220

25

14,1

14,119,6

24,5

12,9

12,918,9

23,9

11,4

11,418

23,1

10

1017

22,3

8,5

8,516

21,5

6,9

6,914,7

20,5

5,2

5,213,2

19,4

4,3

4,312,6

18,8

3,6

3,611,7

18,1

11

17,5

10

16,9

8,1

15,5

6,2

13,9

4,2

12 10

MODEL QL/1’

m3/h

0

HP 0kW

13FGC 150 7,5 T6

Dis

char

ge h

ead

in m

eter

sFGC 150 10 T6

FGC 150 15 T4FGC 150 20 T4

7,5

10

1520

NominalPower

5

7,5

1115

300

18

600

36

900

54

1200

72

1800

108

2400

144

3000

180

3600

216

4200

252

4800

288

5400

324

6000

360

6600

396

7200

432

7800

468

FGC 150 30 T4 3022

15

17

2034,3

11 9,813,6

16

1830

912,8

15,4

1728

8,512

14,9

1626,2

7,510,3

13,2

1423,9

6,88,5

11,8

12,721,5

4,86,6

10

11,619,5

1,84,7

8,1

1118

3,2

6,5

1016,2

8,515,2 14 12,3 11 9,5 8

MODEL QL/1’

m3/h

0

HP 0kW

Dis

char

ge h

ead

in m

eter

s

8,5FGV 65 1,5 T4

FGV 65 2,5 T4FGV 65 2,5 T2FGV 65 3 T2

1,5

2,52,53

NominalPower

1,1

1,81,82,2

50

3

100

6

200

12

300

18

400

24

600

36

800

48

1000

60

1200

72

1400

84

1600

96

1800

108

2000

120

2200

132

2400

144

FGV 80 4 T4FGV 80 5 T4

FGV 80 4 T2

FGV 80 5 T2

4

5

4

5

3

3,7

3

3,7

FGV 80 6 T2FGV 80 7,5 T2

FGV 100 6,5 T6

FGV 100 7 T4

6

7,5

6,5

7

4,4

5,5

4,8

5

FGV 100 10 T4FGV 100 10 T2

FGV 100 15 T2

FGV 100 20 T2

10

10

15

20

7,5

7,5

11

15

9

15,6

18

8

9,5

15,4

18,7

22,3

25

9,5

14,1

17

24

31

40

8,4

8,8

15,4

17,6

8,3

8,7

14,9

17

8

8,3

13,6

15,6

7,4

8,9

13,2

17,5

20,4

23,4

7,4

7,8

11,9

14

7,1

8,5

12

16,5

19,1

22,6

21,5

26,8

6,5

7,2

10

12,2

6,8

8,1

10,8

15,3

17,9

21,9

8,8

12,6

16

20,5

25,8

36,6

4,4

5,4

5,9

8,3

6,2

7,4

8

12,6

15,2

20,2

8,4

11,5

15,3

18,3

23,8

34,3

5,6

6,5

5,4

9,4

12,8

18,5

7,9

10,2

14,8

16,2

22

32

4,9

5,6

6,2

10

16,5

7,4

9

13,8

14,2

20

29,8

4,1

4,6

7,5

14

6,8

7,7

12,9

12,3

18,2

27,6

3,3

3,5

5

6,1

6,3

11,9

10,4

16

25

5,4 4,6

4

9,9

3,7

8,8

2,8

7,8

1,9

6,8

5,1

Selection table

10,9

Page 190: Electric Pumps Catalogue

195

FG

FGSUBMERSIBLE PUMPS FOR WASTE WATER

FG

Performance range

FGT 50

FGV 65

FGV 80

FGV 100

FGC 150

Application table

FGT 50

FGV 65

FGV 80

FGV 100

FGC 150

MODEL

APPLICATIONS

Impeller

Cutter plateimpeller

Vortex

Vortex

Vortex

Single channel

Rainfilteredwaters

Sewagefilteredwaters

Mixedfilteredwaters

Greyclean

waters

Wastedomestic

waters

Greywaters

Nonfilteredmixedwaters

Recycledor activesludges

Livestockslurries

Industrialslurries

Sewagewaters

withsolidsand

fibres

Liquidswith

cloggingand

filamentingfibres

4 / 6 poles motors advised

Tota

l man

omet

ric h

ead

in m

Capacity

Page 191: Electric Pumps Catalogue

FGTSUBMERSIBLE PUMPS FOR WASTE WATERCUTTER PLATE IMPELLER

These high pressure pumps are designed to transfer solids through small bore pipeworkwater with solids in suspension.Max diam. 38 mm, without long fibresMade in high quality engineering cast ironHigh efficency open impeller with high resistance stainless steel four-knives intakecutting system.

196

Motor- Dry chamber motor — insulation class F.- IP68 protection- Motor electric supply voltage: three-phase 3x400V 50Hz, single-phase 1x230V 50Hz- Rotor supported by long-life self-lubricated rolling bearings.- Winding protection by means of a sealed chamber, filled with oil, which is fitted between pump and motor. Dynamic oil seal ensured by two mechanical seals.- Single-phase version with thermal protection and condensers placed in proper box with contact breaker allowing starting also when knives cause overload conditions.- Single-phase models are available in two versions: Automatic starting with float switch Direct starting without float switch- Max startings per hour: 30

Applications- Contamined water- Sewage with fibres- Industrial waste and animal slurry chemically compatible with the pump construction materials.

Usage limitations- Max temperature of pumped liquid: 40¡C- Max immersion depth: 20 m- Running positioning: only vertical- Outlet nominal diameter: 2 gas- For continuous operation, within the allowed use limits, the submersible pump must be submerged for 2/3 of its height, at least.- Suitable for fixed installation, with rapid coupling device or more portable applications suspended or rested. Free passage: 5 mm

Pump casingImpeller

Motor shaft

Motor casing

EN GJL 200

AISI 420 stainless steel

EN GJL 200

EN GJL 200

Component Material

DESIGN FEATURES

Mechanical seal (pump side) Silicon carbide/Silicon carbide

Mechanical seal (motor side) Ceramic/Graphite

OR gasket NBR rubber

Blade AISI 440C stainless steel

Cable lock Brass

Cable 10 m H07RN - F

Page 192: Electric Pumps Catalogue

FG

T 5

0

FGT 50

197

SUBMERSIBLE PUMPS FOR WASTE WATER - CUTTER PLATE IMPELLER

TABLE OF HYDRAULIC PERFORMANCE

Q-H = UNI EN ISO 9906Sedimentation riskIntermittent running

Curves established for liquids density 1kg/dm , with velocity not less than 1 m/s and same viscosity as water.

Hm

0

2

4

6

8

10

12

14

16

25 50 75 100 125 150 175 200 225 275250 300 325 350 375 4001.6 3.3 5 6.6

3 6 9 12 15 18 21 2400

20

18

26

24

22

Q l/sl/min

3m /h

FGT 50 1,5 M2

FGT 50 2 T2

FGT 50 2,5 T2

3

Page 193: Electric Pumps Catalogue

198

FGT 50SUBMERSIBLE PUMPS FOR WASTE WATER - CUTTER PLATE IMPELLER

A

B

C

D

E

DIMENSIONS AND WEIGHTS

Model Dimensions mm.

A

Free borefl (mm)

kg

538445 145 270 fl 2 110 80 fl 3/4 fl 2 110 150 410 38 140 100 130

538445 145 270 fl 2 110 80 fl 3/4 fl 2 110 150 410 38 140 100 130

B C D E L N

Weight

F G H I M O P Q

FGT 50 1,5 M2

FGT 50 1,5 M2 AUT

FGT 50 2 T2

FGT 50 2,5 T2

445

445

145

145

270

270

fl 2

fl 2

110

110

80

80

fl 3/4

fl 3/4

fl 2

fl 2

110

110

150

150

410

410

38

38

140

140

100

100

130

130

39

40

5

5

PUMP PERFORMANCE

MODELCODEVoltage

QL/1’

m3/h

0

HP 0

50

3kW

nmin-1

Nominalpower

Dis

char

ge h

ead

in m

eter

s

15,2FGT 50 1,5 M2N2160010

HP kW

Absorbedpower

Ratedcurrent

AV

FGT 50 1,5 M2 AUTN2160020

FGT 50 2 T2N2160030

FGT 50 2,5 T2N2160040

1,1

1,1

1,5

1,8

1,35

1,35

2,6

2,6

1 230

1 230

3 400

3 400

8

8

6

6,4

20+40

20+40

-

-

2820

2820

2800

2830

F

75

4,5

100

6

150

9

200

12

250

15

300

18

325

19,5

15,2

20

25

12,9

12,9

18,9

23,9

11,4

11,4

18

23,1

10

10

17

22,3

6,9

6,9

14,7

20,5

3,6

3,6

11,7

18,1

8,1

15,5

4,2

12 10

1,5

1,5

2

2,5

1,81

1,81

3,49

3,49

F

G

H

I

L

M

N

O

P

Q

Page 194: Electric Pumps Catalogue

FGVSUBMERSIBLE PUMPS FOR WASTE WATERVORTEX IMPELLER

Made in high quality engineering cast iron.Vortex impeller.The submersible pumps are supplied complete with threaded counterflanges, packingsand stainless steel bolts.

199

Motor- Dry chamber motor — insulation class F- IP68 protection- Motor electric supply voltage: three-phase 3x400V 50Hz- Starting: D.O.L till 5,5 kW Star/delta since 5,5 kW- Rotor supported by long-life self-lubricated rolling bearings- Winding protection by means of a sealed chamber, filled with oil, which is fitted between pump and motor. Dinamic oil seal ensured by two mechanical seals- Max startings per hour: 30 FGV 65

20 FGV 8020 <= 5,5 kW — 15 > 5,5 kW FGV100

Applications- Sewage with suspended solids including long fibres.- For liquid mixing in stock tanks, for industrial waste and animal slurry with solids in suspension.

Usage limitations- Max temperature of pumped liquid: 40¡C- Max immersion depth: 20 m- PH: between 6-11- Running positioning: only vertical- Outlet nominal diameter: DN65 FGV 65 DN80 FGV 80 DN100 FGV 100- For continuous operation, within the allowed use limits, the submersible pump must be submerged for 2/3 of its height, at least.- Suitable for fixed installation with coupling foot, guide rails and chain, or more portable applications suspended or rested.- Free passage: 62 mm FGV 65 50-80 mm FGV 80

83-98 mm FGV 100

Pump casingImpeller

Motor shaft

Motor casing

EN GJL 200

AISI 420 stainless steel

EN GJL 200

EN GJL 200

Component Material

DESIGN FEATURES

Mechanical seal (pump side) Silicum carbide/Silicum carbide

Mechanical seal (motor side)FGV 65 EPDM rubberFGV 80 Carbon/AluminaFGV 100 Carbon/Steel

OR gasket NBR rubber

Cable lock Brass

Cable 10 m H07RN - F

Page 195: Electric Pumps Catalogue

FGV 65

200

SUBMERSIBLE PUMPS FOR WASTE WATER - VORTEX IMPELLER

TABLE OF HYDRAULIC PERFORMANCE

4 POLES

2 POLES

Q-H = UNI EN ISO 9906Sedimentation riskIntermittent running

Curves established for liquids density 1kg/dm , with velocity not less than 1 m/s and same viscosity as water.

16

14

12

10

8

6

4

2

18

20

Hm

500 100 150 200 250 300 350 400 450 500 550 600 650 700 750 80000

2.5 5 7.5 10 12.5243 96 12 15 18 21 3327 30 3936 42 4845

Q l/sl/min

3m /h

Hm

8

7

6

5

4

3

2

1

500 100 150 200 250 300 350 400 450 500 550 600 650 700 750 80000

2.5 5 7.5 10 12.5243 96 12 15 18 21 3327 30 3936 42 4845

9

10

Q l/sl/min

3m /h

FGV 65 2,5 T4FGV 65 1,5 T4

FGV 65 3 T2FGV 65 2,5 T2

3

Page 196: Electric Pumps Catalogue

201

FG

V

FGV 65SUBMERSIBLE PUMPS FOR WASTE WATER - VORTEX IMPELLER

FD

G UNI 2253

CB

E

A

DIMENSIONS AND WEIGHTS

Model Dimensions mm.

A

Free borefl (mm)

kg

6241515 273 217 90 158 62 fl2 1/2

6245515 273 217 90 158 62 fl2 1/2

B C D E

Weight

F G

FGV 65 1,5 T4

FGV 65 2,5 T4

FGV 65 2,5 T2

FGV 65 3 T2

515

515

273

273

217

217

90

90

158

158

62

62

fl2 1/2

fl2 1/2

40

47

62

62

80

80

H

80

80

190

190

I

190

190

fl 3/4

fl 3/4

L

fl 3/4

fl 3/4

530

530

M

530

530

fl2 1/2

fl2 1/2

N

fl2 1/2

fl2 1/2

110

110

O

110

110

150

150

P

150

150

418

418

Q

418

418

38

38

R

38

38

140

140

S

140

140

100

100

T

100

100

130

130

U

130

130

228

228

V

228

228

PUMP PERFORMANCE

MODELCODEVoltage

QL/1’

m3/h

0

HP 0kW

nmin-1

Nominalpower

Dis

char

ge h

ead

in m

eter

s

8,5FGV 65 1,5 T4N2150010

HP kW

Absorbedpower

Ratedcurrent

AV

FGV 65 2,5 T4N2150020

FGV 65 2,5 T2N2150030

FGV 65 3 T2N2150040

1,1

1,8

1,8

2,2

1,75

2,5

2,6

3,31

3 400

3 400

3 400

3 400

3,3

4,5

4,5

5,4

1400

1425

2838

2840

9

15,6

18

100

6

8,3

8,7

14,9

17

200

12

8

8,3

13,6

15,6

300

18

7,4

7,8

11,9

14

400

24

6,5

7,2

10

12,2

500

30

5,4

6,4

8

10,3

600

36

4,4

5,4

5,9

8,3

650

39

4,8

4,8

7,2

700

42

4,3

1,5

2,5

2,5

3

2,35

3,35

3,49

4,44

H I

L

N

O

P

Q

M

R

S

T

U

V

Page 197: Electric Pumps Catalogue

FGV 80

202

SUBMERSIBLE PUMPS FOR WASTE WATER - VORTEX IMPELLER

TABLE OF HYDRAULIC PERFORMANCE

2 POLES

Q-H = UNI EN ISO 9906Sedimentation riskIntermittent running

Curves established for liquids density 1kg/dm , with velocity not less than 1 m/s and same viscosity as water.

Hm

16

14

12

10

8

6

4

2

1000 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 16000

0

1.6

6

18

20

3.3

12

5

18

6.6

24

8.3

30

10

36

11.6

42

13.3

48

15

54

16.6

60

18.3

66

20

72

21.6

78

23.3

84

25

90

26.6

96

22

24

26

Q l/sl/min

3m /h

FGV 80 7,5 T2

FGV 80 6 T2FGV 80 5 T2FGV 80 4 T2

3

Hm

8

7

6

5

4

3

2

1

1000 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 160000

1.66

9

10

180017003.312

518

6.624

8.330

1036

11.642

13.348

1554

16.660

18.366

2072

21.678

23.384

2590

26.696

28.3102

30108

Q l/sl/min

3m /h

4 POLES

FGV 80 5 T4FGV 80 4 T4FGV 80 3 T4

Page 198: Electric Pumps Catalogue

203

FG

V

FGV 80SUBMERSIBLE PUMPS FOR WASTE WATER - VORTEX IMPELLER

B

A

C

D

E

F

G UNI 2254

DIMENSIONS AND WEIGHTS

Model Dimensions mm.

A

Free borefl (mm)

kg

8073620 315 270 125 185 82 fl 3

8076620 315 270 125 185 82 fl 3

B C D E

Weight

F G

FGV 80 4 T4

FGV 80 5 T4

FGV 80 4 T2

FGV 80 5 T2

620

620

365

365

270

270

125

125

203

203

67

67

fl 3

fl 3

70

72

67

67

353

353

H

353

353

110

110

I

110

110

422

422

J

422

422

330

330

K

330

330

175

175

L

175

175

180

180

M

180

180

fl 2

fl 2

N

fl 2

fl 2

fl 3

fl 3

O

fl 3

fl 3

fl160

fl160

P

fl160

fl160

480

480

Q

480

480

700

700

R

700

700

220

220

S

220

220

375

375

T

375

375

240

240

U

240

240

150

150

V

150

150

390

390

W

390

390

638

638

X

638

638

FGV 80 6 T2 620 365 270 125 203 67 fl 3 74 67353 110 422 330 175 180 fl 2 fl 3 fl160 480 700 220 375 240 150 390 638

FGV 80 7,5 T2 620 365 270 125 203 67 fl 3 76 50353 110 422 330 175 180 fl 2 fl 3 fl160 480 700 220 375 240 150 390 638

PUMP PERFORMANCE

MODELCODEVoltage

QL/1’

m3/h

0

HP 0kW

nmin-1

Nominalpower

Dis

char

ge h

ead

in m

eter

s

8FGV 80 4 T4N2150050

HP kW

Absorbedpower

Ratedcurrent

AV

FGV 80 5 T4N2150060

FGV 80 4 T2N2150070

FGV 80 5 T2N2150080

3

3,7

3

3,7

5,71

5,75

4,95

5,8

3 400

3 400

3 400

3 400

7,4

8,8

6,5

8,5

1440

1445

2830

2890

FGV 80 6 T2

FGV 80 7,5 T2

N2150090

N2150100

4,4 7,22 3 400 10 2910

5,5 6,74 3 400 12 2900

9,5

15,4

18,7

22,3

25

200

12

7,4

8,9

13,2

17,5

20,4

23,4

400

24

6,8

8,1

10,8

15,3

17,9

21,9

500

30

6,5

7,8

9,3

14

16,6

21

600

36

6,2

7,4

8

12,6

15,2

20,2

800

48

5,6

6,5

5,4

9,4

12,8

18,5

1000

60

4,9

5,6

6,2

10

16,5

1100

66

4,5

5

8,8

15,3

1200

72

4,1

4,6

7,5

14

1300

78

3,7

4,1

6,3

12,5

1400

84

3,3

3,5

5

1500

90

2,8

3

4

5

4

5

6

7,5

7,66

7,71

6,64

7,78

9,68

9,04

H K

L M

I

J X

W

U V

S

R

Q

T

P

O

N

6FGV 80 3 T4N2150220 2,2 4,8 3 400 5,6 1440 5,6 5,1 4,8 4,4 3,8 3,1 2,8 2,4 2,13 6,55

8070620 295 270 125 160 67 fl 3FGV 80 3 T4 353 110 460 415 175 180 fl 2 fl 3 fl160 480 700 220 375 240 150 390 615

Page 199: Electric Pumps Catalogue

FGV 100

204

SUBMERSIBLE PUMPS FOR WASTE WATER - VORTEX IMPELLER

TABLE OF HYDRAULIC PERFORMANCE

4 - 6 POLES

2 POLES

Q-H = UNI EN ISO 9906Sedimentation riskIntermittent running

Curves established for liquids density 1kg/dm , with velocity not less than 1 m/s and same viscosity as water.

Q

Hm

3

l/s

16

14

12

10

8

6

4

2

2000 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 320000

3.312

6.624

1036

13.348

16.660

2072

23.384

26.696

30108

33.3120

36.6132

40144

43.3156

46.6168

50180

53.3192

20

18

l/min

m /h

FGV 100 10 T4

Q

Hm

3

l/s

16

1412

10

864

2

1000 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 160000

1.66

18

180017003.312

518

6.624

8.330

1036

11.642

13.348

1554

16.660

18.366

2072

21.678

23.384

2590

26.696

28.3102

30108

20

24

22

262830

3432

36

40

38

l/min

m /h

FGV 100 7 T4FGV 100 6,5 T6

FGV 100 20 T2

FGV 100 15 T2FGV 100 10 T2

3

Page 200: Electric Pumps Catalogue

205

FG

V

FGV 100SUBMERSIBLE PUMPS FOR WASTE WATER - VORTEX IMPELLER

A

BC

E

D

G

F

UNI 2254

T UNI 2254

H I L

M N O

P

K

J

Y

X

WV

U

Q

SR

DIMENSIONS AND WEIGHTS

Model Dimensions mm.

A

Free borefl (mm)

kg

98143774 410 366 227 225 100 fl 4

98143774 410 366 227 225 100 fl 4

B C D E

Weight

F G

FGV 100 6,5 T6

FGV 100 7 T4

FGV 100 10 T4

FGV 100 10 T2

774

774

410

410

366

366

227

227

225

225

100

100

fl 4

fl 4

158

142

98

83

300

300

H

300

300

355

355

I

355

355

110

110

J

110

110

520

520

K

520

520

410

410

L

410

410

185

185

M

185

185

225

225

N

225

225

200

200

O

200

200

fl 2

fl 2

P

fl 2

fl 2

774

774

Q

774

774

547

547

R

547

547

227

227

S

227

227

fl 4

fl 4

T

fl 4

fl 4

420

420

U

420

420

280

280

V

280

280

180

180

W

180

180

460

460

X

460

460

730

730

Y

730

730

FGV 100 15 T2 874 410 366 227 225 100 fl 4 160 83300 355 110 520 410 185 225 200 fl 2 874 647 227 fl 4 420 280 180 460 730

FGV 100 20 T2 874 410 366 227 225 100 fl 4 200 83300 355 110 520 410 185 225 200 fl 2 874 647 227 fl 4 420 280 180 460 730

PUMP PERFORMANCE

MODELCODEVoltage

QL/1’

m3/h

0

HP 0kW

nmin-1

NominalPower

Dis

char

ge h

ead

in m

eter

s

9,5FGV 100 6,5 T6N2150110

HP kW

Absorbedpower

Ratedcurrent

AV

FGV 100 7 T4N2150120

FGV 100 10 T4N2150130

FGV 100 10 T2N2150140

4,8

5

7,5

7,5

6,12

6,6

12

11,8

3 400

3 400

3 400 Y/˘

3 400 Y/˘

11

12

20

21

965

1450

1450

2915

FGV 100 15 T2

FGV 100 20 T2

N2150150

N2150160

11 13,5 3 400 Y/˘ 23 2890

15 17,6 3 400 Y/˘ 31 2920

14,1

17

24

31

40

400

24

8,8

12,6

16

20,5

25,8

36,6

600

36

8,4

11,5

15,3

18,3

23,8

34,3

800

48

79

10,2

14,8

16,2

22

32

1000

60

7,4

9

13,8

14,2

20

29,8

1200

72

6,8

7,7

12,9

12,3

18,2

27,6

1400

84

6,1

6,3

11,9

10,4

16

25

1600

96

5,4

5,1

10,9

1800

108

4,6

4

9,9

2000

120

3,7

8,8

2200

132

2,8

7,8

2400

144

1,9

6,8

6,5

7

10

10

15

20

8,21

8,85

16,09

15,82

18,10

23,60

Page 201: Electric Pumps Catalogue

FGCSUBMERSIBLE PUMPS FOR WASTE WATERSINGLE CHANNEL IMPELLER

Made in high quality engineering cast iron EN-GJL 250/25.Single channel impeller provided with wear swivel and fixed wearing mounted in thediffuser.The submersible pumps are supplied complete with threaded counterflanges, packingsand stainless steel bolts.

206

Motor- Dry chamber motor — insulation class F- IP68 protection- Motor electric supply voltage: three-phase 3x400V 50Hz- Starting: star/delta- Rotor supported by long-life self-lubricated rolling bearings- Winding protection by means of a sealed chamber, filled with oil, which is fitted between pump and motor. Dynamic oil seal ensured by two mechanical seals.- Max startings per hour: 15

Applications- Sewage, effluent and rainwaters without long fibres- Animal slurry, industrial water with solids in suspension of max diameter of 108 mm according to pumps size

Usage limitations- Max temperature of pumped liquid: 40¡C- Max immersion depth: 20 m- PH: between 6-11- Running positioning: only vertical- Outlet nominal diameter: DN150- For continuous operation, within the allowed use limits, the submersible pump must be submerged for 2/3 of its height, at least.- Suitable for fixed installation with coupling foot, guide rails and chain, or more portable applications suspended or rested.- Free passage: 95-108 mm.

Pump casingImpeller

Motor shaft

Motor casing

EN GJL 250

AISI 420 stainless steel

EN GJL 250

EN GJL 250

Component Material

DESIGN FEATURES

Mechanical seal (pump side) Silicum carbide / Silicum carbide

Mechanical seal (motor side) Ceramic / Graphite

OR gasket NBR rubber

Cable lock Brass

Cable 10 m H07RN - F

Page 202: Electric Pumps Catalogue

FG

C 1

50

FGC 150

207

SUBMERSIBLE PUMPS FOR WASTE WATER - SINGLE CHANNEL IMPELLER

TABLE OF HYDRAULIC PERFORMANCE

6 POLES

4 POLES

Q-H = UNI EN ISO 9906Sedimentation riskIntermittent running

Curves established for liquids density 1kg/dm , with velocity not less than 1 m/s and same viscosity as water.

FGC 150 30 T4

Hmft

Q l/s

l/min

3m /h

FGC 150 20 T4

FGC 150 15 T4

Hm

Q l/s

l/min

3m /h

16

FGC 150 10 T6

FGC 150 7,5 T6

3

Page 203: Electric Pumps Catalogue

208

FGC 150SUBMERSIBLE PUMPS FOR WASTE WATER - SINGLE CHANNEL IMPELLER

E

GF

C

B

A

D

H

I UNI 2254

JK L

M

N

O

S UNI 2254

V

W

Q

PR

TU

Y

X

DIMENSIONS AND WEIGHTS

Model Dimensions mm.

A

Freebore

fl (mm)kg

95200950 190 590 301 602 240 362

1083001150 190 590 317 657 271 386

B C D E F G

FGC 150 7,5 T6

FGC 150 10 T6

FGC 150 15 T4

FGC 150 20 T4

950

950

190

190

590

590

301

301

602

602

240

240

362

362

212

226

95

95

150

150

H

150

150

DN 150

DN 150

I

DN 150

DN 150

810

871

J

810

810

240

271

K

240

240

570

600

L

570

570

70

70

M

70

70

fl 2

fl 2

N

fl 2

fl 2

229

229

O

229

229

650

835

P

650

650

970

1155

Q

970

970

320

320

R

320

320

DN 150

DN 150

S

DN 150

DN 150

450

450

T

450

450

70

70

U

70

70

300

300

V

300

300

1100

1174

W

1100

1100

105

105

X

105

105

275

275

Y

275

275

FGC 150 30 T4 1150 190 590 317 657 271 386 340 108150 DN 150 871 271 600 70 fl 2 229 835 1155 320 DN 150 450 70 300 1174 105 275

PUMP PERFORMANCE

MODELCODEVoltage

QL/1’

m3/h

0

HP 0kW

nmin-1

Nominalpower

Dis

char

ge h

ead

in m

eter

s

13FGC 150 7,5 T6N2150170

HP kW

Absorbedpower

Ratedcurrent

AV

FGC 150 10 T6N2150180

FGC 150 15 T4N2150190

FGC 150 20 T4N2150200

5

7,5

11

15

6,3

6,3

15,5

19

3 400 Y/˘

3 400 Y/˘

3 400 Y/˘

3 400 Y/˘

12

19

26

31

950

950

1450

1450

FGC 150 30 T4N2150210 22 25 3 400 Y/˘ 46 1450

15

17

20

34,3

600

36

9,8

13,6

16

18

30

1200

72

8,5

12

14,9

16

26,2

1800

108

7,5

10,3

13,2

14

23,9

2400

144

6,8

8,5

11,8

12,7

21,5

3000

180

4,8

6,6

10

11,6

19,5

3600

216

1,8

4,7

8,1

11

18

4200

252

3,2

6,5

10

16,2

4800

288

8,5

15,2

6000

360

12,3

6600

396

11

7200

432

9,5

7,5

10

15

20

30

8,45

8,45

20,79

25,48

33,53

Weight

Page 204: Electric Pumps Catalogue

Access

ori

es

Accessories

209

ZA009940 D 6,5 - ZN (m. 10) Galvanized steel lifting chain with EyeboltFGC 150

D 6,5 - ZN (m. 5) Galvanized steel lifting chain with EyeboltFGT 50FGV 65FGV 80

ZA009930

FGV 100

CODEPUMP TYPE DESCRIPTION

Starter for 1 pumpcontrol and protection

PUMP TYPE

VoltageStarter for 2 pumpscontrol and protection

Current

min maxCODE DESCRIPTIONCODE DESCRIPTION

FGT 50 1,5 M2

FGT 50 2 T2

FGT 50 2,5 T2

FGV 65 1,5 T4

FGV 65 2,5 T4

FGV 65 2,5 T2

FGV 65 3 T2

FGV 80 4 T4

FGV 80 5 T4

FGV 80 4 T2

FGV 80 5 T2

FGV 80 6 T2

FGV 80 7,5 T2

FGV 100 6,5 T6

FGV 100 7 T4

FGV 100 10 T4

FGV 100 10 T2

FGV 100 15 T2

FGV 100 20 T2

FGC 150 7,5 T6

FGC 150 10 T6

FGC 150 15 T4

FGC 150 20 T4

FGC 150 30 T4

UZQ06800

UZQ07500

UZQ07400

UZQ07500

UZQ07600

UZQ07500

UZQ07600

UZQ07700

UZQ07700

UZQ08100

UZQ08200

UZQ07900

UZQ08100

UZQ08200

UZQ08400

ADRM 10/110

ADRD 10/300

ADRD 10/150

ADRD 10/300

ADRD 10/400

ADRD 10/300

ADRD 10/400

ADRD 10/550

ADRD 10/550

ADRY 10/1100

ADRY 10/1500

ADRY 10/550

ADRY 10/1100

ADRY 10/1500

ADRY 10/2200

UZQ08900

UZQ09600

UZQ09500

UZQ09600

UZQ09700

UZQ09600

UZQ09700

UZQ09800

UZQ09800

UZQ10200

UZQ10300

UZQ10000

UZQ10200

UZQ10300

UZQ10500

ADRM 20/110

ADRD 20/300

ADRD 20/150

ADRD 20/300

ADRD 20/400

ADRD 20/300

ADRD 20/400

ADRD 20/550

ADRD 20/550

ADRY 20/1100

ADRY 20/1500

ADRY 20/550

ADRY 20/1100

ADRY 20/1500

ADRY 20/2200

1 x 230

3 x 400

3 x 400

3 x 400

3 x 400

3 x 400

3 x 400

3 x 400

3 x 400

3 x 400

3 x 400

3 x 400

3 x 400

3 x 400

3 x 400

6

4,5

3

4,5

6

4,5

6

9

9

15,6

24,2

10,4

15,6

24,2

34,5

9,5

7,1

4,7

7,1

9,5

7,1

9,5

14,2

14,2

24,5

34,4

15,5

24,5

34,4

54

ADF DN 80 Adaptor DN 80 (for flygt coupling foot)ZA009840

ADF DN 65 Adaptor DN 65 (for flygt coupling foot)ZA009830

MODELCODE DESCRIPTION

ADF DN 100 Adaptor DN 100 (for flygt coupling foot)ZA009850

CODE MODEL DESCRIPTION

ZA009730ZA009740ZA009750ZA009760ZA009770

PDA FGT 50PDA FGV 65PDA FGV 80PDA FGV 100PDA FGC 150

COUPLING FOOT FGT 50COUPLING FOOT FGV 65COUPLING FOOT FGV 80COUPLING FOOT FGV 100COUPLING FOOT FGC 150

CODE MODEL DESCRIPTION

ZA009310ZA009780ZA009790ZA009800ZA009810

VRP 2VRP DN 65VRP DN 80VRP DN 100VRP DN 150

STAINLESS STEEL 2 F BALL CHECK VALVEBALL CHECK VALVE DN 65BALL CHECK VALVE DN 80BALL CHECK VALVE DN 100BALL CHECK VALVE DN 150

Page 205: Electric Pumps Catalogue

VACUSYSTEMMINI COLLECTION AND PUMPING STATIONS FORWASTE WATER

The VACUSYSTEM 85 are pre-assembled ready-for-use automatic pumping stations,designed for the disposal of domestic waste water in houses and small blocks of flats.Particularly suitable when the water from skin drains, baths, washing machines (excludingthat of WCs) etc. is collected at a lower level than the main sewer.The standard pumping station consists of DRENOX submersible pump.

210

Electric pump motor- Dry motor- Single phase power supply with capacitor permanently activated and thermal protection built into the motor winding- Level of protection IP68- Class F insulation- Speed of rotation 2850 rpm- Completely insulated cable connection chamber- 10 m H07 RN-F power supply cable with plug

Usage limitations- Type of liquid: partially effluent and dirty clear water, with suspended solids of a maximum dimension of 6 mm, non-aggressive liquids- Maximum liquid temperature 40¡C

Accessories (only on request)- Sealing lid to be fitted in place of the grid (Art. ZA008290)

Design features- The standard pumping station consists of:- Tank In polyethylene with a capacity of 85 litres with corrosion and wear resistant sand filter bowl and grid. Three possible types of 40 fl pipe inlet.- Flexible pipe 1 1/4" helically wound complete with a sleeve for the connection of the delivery pipe for both right-hand and left-hand connection- Non return valve- Plug with built in thermal protection and switch for manual/automatic operation.- DRENOX automatic submersible pump

Component

Impeller

Pump body

Motor shaft

Material

X 5 CrNi 1810 (AISI 304) Cast stainless steel

X 5 CrNi 1810 (AISI 304) Stainless steel

Stainless steel seal with a ceramicfacing at the points of seal wear

Suction grid X 5 CrNi 1810 (AISI 304) Stainless steel

Power cable 10 m H07 RN-F with plug

Seal Fixed double NBR 70 rubber seal with specialV-ring sand guard.

DRENOX DESIGN FEATURES

Page 206: Electric Pumps Catalogue

211

TABLE OF HYDRAULIC PERFORMANCE

VACUSYSTEM

PUMP PERFORMANCE

MODELCODE

Absorbedpower

kWVOLTAGE Amp. F. Q

L/1’

m3/h

10Nominalpower

HP

Discharge head

in meters

0,6

80

4,8

120

7,2

40

2,4

60

3,6kW HP

160

9,6

1 ~ 220 240 VVS 85-D 160 N2141000 0,6 0,450,5 0,37 7 5,8 5 4,1 2,2

1 ~ 220 240 V N2141010 1,2 0,90,75 0,55 9,4 8,5 7,6 7,2 5,1 4,1

2,2

4,5

8

10VS 85-D 250

DIMENSIONS AND WEIGHTS

21,4300 250 503 620 50 85 130 45

H I

570

L

400

M

200

N

600

O

485

P

VS 85-D 160

VS 85-D 250

505 40

R

250

Q

22,5300 250 503 620 50 85 130 45 570 400 200 600 485505 40250

B C D E

Weight

F G

ModelDimensions mm.

A kg

L / 1’m3/ h

Q

Hm

160/8

200 50 300 3 12 18

10

6

150 9

2

8

100

6

250

15

12

4

250/10

Page 207: Electric Pumps Catalogue

212

VACUSYSTEMCOLLECTION AND PUMPING STATIONS FORDIRTY WATER

The VACUSYSTEM 200 are pre-assembled ready-for-use automatic pumping stations.Particularly suitable when the water from drains is collected at a lower level than themain sewer.The standard pumping station consists of PRIOX submersible pump.

Electric pump motor- Dry motor- Level of protection IP68- Class F insulation- Single phase power supply with capacitor permanently activated and thermal protection built into the motor winding- Completely insulated cable connection chamber- Speed of rotation 2850 rpm- Self lubricating ball bearings

Usage limitations- Type of liquid: water with suspended solids of a maximum dimension of 40 mm- Maximum liquid temperature 40¡C- Minimum drainage level 60 mm

Design featuresThe standard pumping station consists of:- Tank in polyethylene with a capacity of 175 l. The closing lid is supplied with O-ring. It warrants liquid seal and possible gas locks.- DN 110 inlet, 2 outlet and DN 50 vent connection- Plug With thermal protection and test-push button- PRIOX 300/9 AUT, PRIOX 460/13 M AUT submersible pump

Oil chamber forseal lubrication

Component

Impeller

Pump casing

Motor shaft

Mechanical seal

Counterface

Material

X 5 CrNi 1810 (AISI 304) Stainless steel

X 12 CrNi 1809 (AISI 416) Stainless steel

Silicon carbide

Silicon carbide

PRIOX DESIGN FEATURES

Suction base X 5 CrNi 1810 (AISI 304) Stainless steel

X 5 CrNi 1810 (AISI 304) Cast stainless steel

Power cable 10 m H07 RN-F

Secondary seal NBR rubber lip seal

V-ring sand protection NBR rubber

Page 208: Electric Pumps Catalogue

213

VA

CU

SYSTE

M

TABLE OF HYDRAULIC PERFORMANCE

VACUSYSTEM

DIMENSIONS AND WEIGHTS

27500

A

380

B

250

C

100

D

185

E

250

F

130

G H

410 350

I

800

L

410

M

350

N

635

O

515

P

720

Q

185

R

85

S

29,2500 380 250 100 185 250 130 410 350 800 410 350 635 515 720 185 85

VS 200 - P 300 M

VS 200 - P 460 M

Weight Model

Dimensions mm.

kg

PUMP PERFORMANCE

MODELCODE

Absorbedpower

kWVOLTAGE Amp. F. Q

L/1’

m3/h

50Nominalpower

HP

Dis

char

ge h

ead

in m

eter

s

3

200

12

250

15

100

6

150

9kW HP

300

18

400

24

1 ~ 230 VVS 200 - P 300 M N2141140

1 ~ 230 VVS 200 - P 460 M N2141150 10,8 9,8 8,5 7 5,5 2

4,1

7,2

12,5

20

6,4 5 3,8 2,3 10,8

1,4

0,6

1

1,2

2,2

0,9

1,6 11,8

7,7

L / 1’m3/ h

Q

Hm

300/9

460/13

500100 6002006 12 30 36

30018

40024

14

12

6

4

2

8

10

Page 209: Electric Pumps Catalogue

VACUSYSTEMCOLLECTION AND PUMPING STATIONS FORDIRTY WATER

The VACUSYSTEM 200S are pre-assembled ready-for-use automatic pumping stations.Particularly suitable when the water from drains is collected at a lower level than themain sewer.The standard pumping station consists of PRIOX submersible pump.

¥ CONNECTING FOOTElectric pump motor- Dry motor- Level of protection IP68- Class F insulation- Single-phase power supply with capacitor permanently activated and thermal protection built into the motor winding- Completely insulated cable connection chamber- Self lubricating ball bearings- Speed of rotation 2850 rpm

Usage limitations- Type of liquid: water with suspended solids of a maximum dimension of 40 mm- Maximum liquid temperature 40¡C- Minimum drainage level 60 mm

214

Design features- The standard pumping station consists of:

- Tank in polyethylene with a capacity of 175 l. The closing lid is supplied with O-ring. It warrants liquid seal and possible gas locks.- DN 110 inlet, 2 outlet and DN 50 vent connection- Connecting foot- Plug With thermal protection and test-push button (single-phase pumps)- Electric panel for the control and protection of three-phase electric pumps.- Float switch with 10 m of 3 x 1 H07 RN-F cable (for three-phase pumps)- PRIOX Submersible Pump Models:- Priox 300/9 M AUT, Priox 300/9 T- Priox 460/13 M AUT, Priox 460/13 T

Oil chamber forseal lubrication

Component

Impeller

Pump casing

Motor shaft

Mechanical seal

Counterface

Material

X 5 CrNi 1810 (AISI 304) Stainless steel

X 12 CrNi 1809 (AISI 416) Stainless steel

Silicon carbide

Silicon carbide

PRIOX DESIGN FEATURES

Suction base X 5 CrNi 1810 (AISI 304) Stainless steel

X 5 CrNi 1810 (AISI 304) Cast stainless steel

Power cable 10 m H07 RN-F

Secondary seal NBR rubber lip seal

V-ring sand protection NBR rubber

Page 210: Electric Pumps Catalogue

215

VA

CU

SYSTE

M

TABLE OF HYDRAULIC PERFORMANCE

VACUSYSTEM

L / 1’m3/ h

Q

Hm

300/9

460/13

500100 6002006 12 30 36

30018

40024

14

12

6

4

2

8

10

DIMENSIONS AND WEIGHTS

A B C D E F G H I L M N O P Q R S

PUMP PERFORMANCE

MODELCODE

Absorbedpower

kWVOLTAGE Amp. F. Q

L/1’

m3/h

50Nominalpower

HP

Dis

char

ge h

ead

in m

eter

s

3

200

12

250

15

100

6

150

9kW HP

300

18

400

24

VS 200 S - P 460 TN2141190

VS 200 S - P 460 T

37500 380 250 100 185 250 130

39500 380 250 100 185 250 130

38,8500 380 250 100 185 250 130

40,6500 380 250 100 185 250 130

N2141170

410 350 800 410 350 635 515 720 185 85

410 350 800 410 350 635 515 720 185 85

410 350 800 410 350 635 515 720 185 85

410 350 800 410 350 635 515 720 185 85

Weight Model

Dimensions mm.

kg

1 ~ 230 VVS 200 S - P 300 M N2141160

1 ~ 230 VVS 200 S - P 460 M N214118010,8 9,8 8,5 7 5,5 2

4,1

7,2

12,5

20

6,4 5 3,8 2,3 1

3 ~ 400 V 2,4

0,8

1,4

1,4

0,6

1

1

1,2

2,2

2

0,9

1,6

1,4511,8

7,7VS 200 S - P 300 T 3 ~ 400 V 1,550,8 0,6 1,2 0,9

VS 200 S - P 300 M

VS 200 S - P 460 M

VS 200 S - P 300 T

Page 211: Electric Pumps Catalogue

216

VACUSYSTEMCOLLECTION AND PUMPING STATIONS FORDIRTY WATER

The VACUSYSTEM 500 are pre-assembled ready-for-use automatic pumping stations.Particularly suitable when the water from drains is collected at a lower level than themain sewer.The standard pumping station consists of PRIOX submersible pump.

¥ 2 SUBMERSIBLE PUMPS¥ 2 CONNECTING FEET¥ ELECTRIC PANEL FOR CONTROL AND PROTECTION

Motor- Dry motor- Level of protection IP68- Class F insulation- Single-phase power supply with capacitor permanently activated and thermal protection built into the motor winding- Completely insulated cable connection chamber- Speed of rotation 2850 rpm- Self lubricating ball bearings

Usage limitations- Type of liquid: water with suspended solids of a maximum dimension of 40 mm- Maximum liquid temperature 40¡C- Minimum drainage level 60 mm

Design features- The standard pumping station consists of:

- Tank In polyethylene with a capacity of 550 l. The closing lid is supplied with O-ring. It warrants liquid seal and possible gas locks.- Two DN 110 inlet, two 2 outlet and DN 50 vent connection- Two connecting feet- Electric panel for the control and protection of 2 single phase or three phase electric pumps- Two float switches with 10 m of 3 x 1 H07 RN-F cable- Pair of PRIOX Submersible Pumps Models:- Priox 300/9 M, Priox 300/9 T- Priox 460/13 M, Priox 460/13 T

Oil chamber forseal lubrication

Component

Impeller

Pump casing

Motor shaft

Mechanical seal

Counterface

Material

X 5 CrNi 1810 (AISI 304) Stainless steel

X 12 CrNi 1809 (AISI 416) Stainless steel

Silicon carbide

Silicon carbide

PRIOX DESIGN FEATURES

Suction base X 5 CrNi 1810 (AISI 304) Stainless steel

X 5 CrNi 1810 (AISI 304) Cast stainless steel

Power cable 10 m H07 RN-F

Secondary seal NBR rubber lip seal

V-ring sand protection NBR rubber

Page 212: Electric Pumps Catalogue

217

Page 213: Electric Pumps Catalogue

PUMPS FOR SPECIAL APPLICATIONS

Page 214: Electric Pumps Catalogue

SWIMMEYSELF-PRIMING PUMPS FOR SWIMMING POOLSWITH PREFILTER

The SWIMMEY pumps have been designed to achieve maximum operationalreliability in filtering and recirculating water treated with chlorine.

Motor— Enclosed, externally ventilated— Level of protection IP X5 with sealed parts— Class F insulation— Single phase power supply with capacitor permanently activated and thermal protection built into the motor winding— Three phase power supply with external protection provided by the user— Self-lubricating ball bearings— Speed of rotation 2850 rpm— Suitable for continuous use

Applications— Recirculation and filtration of water for swimming pools, spas and bathing pools

Usage Limitations— Type of liquid: swimming pool water treated with chlorine— Maximum liquid temperature 40¡C— Maximum operation pressure: 2.5 bar— Maximum recommended suction height: 3m with foot valve

220

Component

Pump body

Prefilter

Impeller

Diffusor

Mechanical seal

Counterface

Material

ABS

ABS

Glass-fibre Reinforced lexan(resistant to abrasion by sand)Glass-fibre Reinforced lexan(resistant to abrasion by sand)

DESIGN FEATURES

Shaft

Large bowl that may beinspected via screw cap Polyethylene HD

Suction and delivery fittings ABS/PVC

Graphite

Ceramic

Stainless steel with insulating part

Support base Polypropilene

Screw filter cap Lexan with teflon-treated locking O ring

Page 215: Electric Pumps Catalogue

221

SW

IMM

EY

TABLE OF HYDRAULIC PERFORMANCE

SWIMMEY

Q

Hm

L / 1'

m3/ h

24

20

16

12

8

4

19

600

36

500

30

400

24

300

18

200

12

100

6

50

3

150

9

250

15

350

21

450

27

550

33

15

12

33

28

24

PUMP PERFORMANCE

MODELCODE

AbsorbedPower

kW

VOLTAGE( V ) Amp. F. Q

L/1’

m3/h

100

HP

Dis

charg

e h

ead

in m

ete

rs

6

300

18

350

21

150

9

200

12kW HP

51 ~ 230 V1 0,75 1,5 1,1

20

NominalPower

13 12 10,5 6 43-1,73 ~ 400 V

4,81 ~ 230 V1 0,75 1,5 1,1

20

15,5 14,5 13 9 74,1-2,43 ~ 400 V

71 ~ 230 V1,5 1,13 2 1,5

30

18,5 17 15,5 12 10,56-3,63 ~ 400 V

8,51 ~ 230 V2 1,5 2, 55 1,9

35

3

2,5

400

24

4,5

8

450

27

6

500

30

0,5

1,5

3,5

SWIMMEY 12 M

SWIMMEY 12 T

1 ~ 230 V

3 ~ 400 V

N7241230

N72412900,5 0,37

109 6 20,75 0,55

SWIMMEY 15 M

SWIMMEY 15 T0,75 0,5

1 ~ 230 V

3 ~ 400 V

1011 8,5 4,5

N7241240

N72413000,9 0,7

15,5 13 10 1,53,3-1,93 ~ 400 V

N7241250

N7241310

N7241260

N7241320

N7241270

N7241330

N7241280

N7241340

SWIMMEY 19 M

SWIMMEY 19 T

SWIMMEY 24 M

SWIMMEY 24 T

SWIMMEY 28 M

SWIMMEY 28 T

SWIMMEY 33 M

SWIMMEY 33 T

2,2-1,3

1,7-1

TABLE OF SIZES AND WEIGHTS

SWIMMEY 33 260

230

230

240

240

260

A B

112

35

35

58

87

112

C

635

565

565

590

610

635

D

183

183

183

183

183

183

E

280

280

280

280

280

280

F

240

240

255

285

310

310

DN

50

50

50

50

50

50

14,5

8

8,5

10,2

11

13

kg

Weight

SWIMMEY 12

SWIMMEY 15

SWIMMEY 19

SWIMMEY 24

SWIMMEY 28

ModelDimension mm.

Page 216: Electric Pumps Catalogue

MCPHORIZONTAL MULTISTAGE CENTRIFUGAL PUMP FOROPERATIONS WITH SWIMMING POOL CLEANERS

222

MCP booster pump is specifically studied for meeting the needs of pool cleaning.

¥ FOR SWIMMING POOL APPLICATIONS¥ EXTREMELY SILENT RUNNING¥ SUITABLE TO WORK WITH SEA WATER

Motor— Enclosed, externally ventilated— Level of protection IP 44— Class F insulation— Single phase power supply with capacitor permanently activated and thermal protection built into the motor winding— Speed of rotation 2850 rpm— Suitable for continuous use

Usage limitations— Type of liquid: clean water with no suspended solids or abrasive material— Swimming pool water treated with chlorine— Sea water— Maximum water temperature 50¡C— Maximum recommended suction height: 6 m with foot valve— Maximum operating pressure 7 bar

Applications- operations with swimming pool cleaners- water coming from swimming pool (containing chlorine), sea water.

Component

Pump body

Motor support

Counterface

ImpellersDiffusers

O’ rings

Material

Polypropylene 30% glass loaded

Die-cast aluminium

Ceramic

Technopolymer with stainless steel inserts

DESIGN FEATURES

Mechanical seal Graphite/ceramic - metallic parts in stainless steel AISI 316

12

3 Seal cover GFN 2V Noryl

45

Technopolymer

67

NBR

8

9

Motor shaft X2 CrNiMo 17-12-2 (AISI 316L)

8 7 1 2 3

546

Page 217: Electric Pumps Catalogue

223

MCP

MC

P

Hm

L / 1’m3/ h

Q

10

1 ~ 230 VMCP 4 0,7 0,5 0,81,1 12,5 42 N4300000 4

PUMP PERFORMANCE

MODELCODE

AbsorbedPower

kWVOLTAGE

( V )Amp. F. Q

L/1’

m3/hHP

1,7 1,25 581,1 0,85MCP 5 N4300010 1 ~ 230 V 5,8 20

0

0kW HP

NominalPower

TABLE OF SIZES AND WEIGHTS

ModelDimension mm.

A

Weight

C kgB D DNA DNM

MCP 5

MCP 4

MCP 4

34

54

20

1,2

27

47

40

2,4

15

36

60

3,6

6

25

80

4,8

E

123

123

370

385

99

99

185

190

174

174

1

1

1

1

7

9

Dischargehead

in meters 11

100

6

20

30

40

50

60

10

0,6

20

1,2

30

1,8

40

2,4

50

3

60

3,6

70

4,2

80

4,8

90

5,4

100

6

MCP 5

B

E

C

A

DNA

DNM

D

TABLE OF HYDRAULIC PERFORMANCE

Page 218: Electric Pumps Catalogue

¥ REDUCE THE COST AND WASTE OF WATER¥ SILENT AND COMFORTABLE SYSTEM¥ COMPACT DESIGN

RainFLOWBOOSTER SYSTEM FOR HARVESTED RAINWATER

The RainFLOW unit is an automatic pumping system designed for monitoring and controllingthe distribution of harvested rainwater. When insufficient rainwater is available from thecollecting tank (e.g. underground tank), the electronic control of RainFLOW switches to thesuction pipe of the main water integrated tank, by means of the built-in three-way valve.In this way, RainFLOW ensures that water is always available at the points of consumption.RainFLOW is supplied together with a self priming multistage centrifugal pump of the MAXseries.

224

ApplicationsRainFLOW is suitable for the transfer andpressurizing of water from rainwatercollection and utilization systems in single-or two-family houses, farms and gardens,as well as in small factories.

Pump motor- Enclosed, externally ventilated- Level of protection IP 44- Class F insulation- Single phase power supply with capacitor permanently activated and thermal protection built into the motor winding- Speed of rotation 2850 rpm- Suitable for continuous use

Technical data - RainFLOWSupply voltageLevel of protection

Installation

Integrated main water tankLevel control

230 Volts - 50 HzIP 55

Ground or wall mounting(bracket with screws are included), indoors.

Polyetilene Capacity: 55 litres

Power supply cable

Pre-set starting pressure 1,5 bar(Maximum height to highest point of consumption: 15m)

Floating switch with 20 m cable1.5 m with Schuko plug

Hydraulic connections Main water pipe: 1/2" MSuction pipe: 1 MDischarge pipe: 1 1/2 FOverflow pipe: 1 F

ComponentPump casingMotor bracket

Shaft (hydraulic end)

Mechanical sealCounterfaceO’ring

MaterialX5 CrNi 1810 (AISI 304) Stainless steelDie-cast aluminium

X5 CrNi 1810 (AISI 304) Stainless steel

Graphite

PUMP DESIGN FEATURES - MAX 80/48

Seal holder plate

Diffusors Technopolymer

Impeller Technopolymer with X5 CrNi 1810 (Aisi 304)Stainless steel shim ring

CeramicNBR 70 ShoreGFN2V Noryl

Spacer OT 58 Nickel plated brass

Features- Automatic changeover between rainwater tank and integrated main water tank- Manual changeover between rainwater tank and integrated main water tank- Once a week, automatic changeover from the rainwater tank to the mains water supply (forced)- Dry running protection with visual alarm in case of lack of water.

Usage limitations- Type of liquid: rainwater with no suspended solids or abrasive material- Liquid temperature: +5¡C to +35¡C- Ambient temperature: 0¡C to +40¡C- Maximum recommended suction height: 7m with foot valve- Maximum operating pressure: 7 bar

Page 219: Electric Pumps Catalogue

255

TABLE OF SIZES AND WEIGHTS

B

70

H2

225

Rain

FLO

W

TABLE OF HYDRAULIC PERFORMANCE

RainFLOW

PUMP PERFORMANCE

MODEL

AbsorbedPower

kW

VOLTAGE( V ) Amp. F. Q

L/1’

m3/h

0

HP

Discharge head

in meters

0

60

3,6

80

4,8

20

1,2

40

2,4kW HP

NominalPower

1,1 0,8 36 28 17 10,75 0,55 RainFLOWMAX 80/48 M 1 ~ 230 V 454 12,5

CODE

N4501200

B

D

FE

C

A

HIH2

H3

LGI

O

N

M

P

Q

Hm

L / 1'm3/ h

20 1,2

20

10 0,6

30 1,8

40 2,4

50

3

60 3,6

70 4,2

80 4,8

10

30

40

50

60

80/48

D I

RainFLOW MAX 80/48 M 555 23480 675

ModelDimension mm.

A

Weight

C kg

205

E

420

F

78

G

617 505 360

H1 H3

235

L

380

M

180

N

798

O

734

P

Page 220: Electric Pumps Catalogue

BLAZE - BLAZEMASTERSINGLE AND TWIN IMPELLER ENGINE DRIVEN PUMPS

The Onga engine driven pumps are particularly suitable where electrical power is notreadily available and when a large quantity of water and pressure is required.

¥ HONDA ENGINE¥ HIGH EFFICIENCY AND PERFORMANCE¥ HIGH FLOW RATE AND PRESSURE¥ HIGH PRIMING CAPACITY¥ ADAPTABILITY TO PIPE CONFIGURATIONS

Applications- Fire Fighting- Tank filling- Water transfer- Hydrants- Irrigation

Usage limitations- Maximum operating pressure: 13 bar- Water temperature range: 5¡ C — 40¡ C- Free clearance of solids: 3 mm (twin impellers) 5 mm (single impeller)- Environment temperature: Max. 40¡ C

226

MOTOR

Cylinder type

BLAZEMASTER

MOTORBLAZE

- Air cooled 4 stroke OHV petrol engine, 25¡ inclined cylinder, horizontal shaft.

Bore stroke

Displacement

Max. power outputStarting systemFuel tank capacitySpecific fuel consumption

Fuel type

Cast iron cylinder

68 x 45 mm

4,0 Kw (5,5 CV) / 3600 rpm Recoil

3,6 lt313 g/kWh - 230 g/CVh

lead-free petrol

68 x 54 mm

196 cm3

4,8 Kw (6,5 CV) / 3600 rpm

Component

Pump casing

Impeller

Shaft

Material

Aluminium

Nylon

Mild steel

DESIGN FEATURES

Counterface Graphite

--- Mechanical seal Ceramic

--

Diffusers Aluminium-O ring NBR-

168 cm3

BY

Page 221: Electric Pumps Catalogue

BLA

ZE

- B

LA

ZE

MA

STE

R

BLAZE - BLAZEMASTER

227

PUMP PERFORMANCE

MODELCODEPower

kWHP

HONDAMOTOR

QL/1’

m3/h

200

12

300

18

400

24

500

30

BLAZE 5.5 HP 5/8in EU GX 1605,5 4 37 30 2047 B55HEU

BLAZE 6.5 HP 5/8in EU GX 2006,5 4,8 45 37 2852 B65HEU

BLAZEMASTER 5.5 HP 5/8in EU GX 1605,5 4 29 250 BM55HEU

BLAZEMASTER 6.5 HP 5/8in EU GX 2006,5 4,8 35 1558 BM65HEU

0

0

61

65

101

101,5

50

3

55,5

62,5

85

91

100

6

50

60

72

79

600

36

12

20

700

42

9,8

TABLE OF HYDRAULIC PERFORMANCE

Hm

L / 1’m3/ h

Q200

12

15

100

6

300

18

400

24

500

30

600

36

700

42

800

48

30

45

60

75

90

105

120

B55H

B65H

BM55H

BM65H

BLAZE 5.5 HP 5/8in EU 312 22,2178 163 253

TABLE OF SIZES AND WEIGHTS

ModelDimensions mm.

A

Weight

C kgB D

BLAZE 6.5 HP 5/8in EU 312 23,2178 166 253

BLAZEMASTER 5.5 HP 5/8in EU 312 22,9178 178 253

BLAZEMASTER 6.5 HP 5/8in EU 312 23,9178 166 253

480

E

480

480

480

1 1/2

DNA

1 1/2

2

2

1 - 1 - 1 1/2 - 1 1/2

4- DNM

1 - 1 - 1 1/2 - 1 1/2

1 - 1 - 2 - 2

1 - 1 - 2 - 2

Dischargehead

in meters

Page 222: Electric Pumps Catalogue

P.G.A. - DELTA OIL SPECIAL SELF-PRIMING LIQUID RING PUMPS FOR DIESEL TRANSFER

The PGA series pumps are particularly suitable for diesel transfer.Version equipped with power supply cable, switch and handle available.

228

Motor- Enclosed, externally ventilated- Level of protection IP44- Class F insulation- Single phase power supply with capacitor permanently activated and thermal protection built into the motor winding- Three phase power supply with external protection provided by the user- Speed of rotation 2850 rpm- Suitable for continuous use

Applications— Manufacture of delivery assemblies— For farm diesel transfer— Farm machines— Small pumping stations

Usage limitations- Type of liquid: diesel- Maximum liquid temperature 50¡C- Maximum recommended suction height 5m with foot valve- Maximum operating pressure 6 bar

Component

Pump casing

Motor bracket

Motor shaft

Mechanical seal

Counterface

O ring

Material

EN GJL 200 (ex G20) Cast iron

EN GJL 200 (ex G20) Cast iron

Graphite

DESIGN FEATURES

Finned impeller

Ceramic

NBR 70 shore

Brass

X 12 CrNiS 1809 (AISI 416) Stainless steel

PGA

DELTA OIL

Page 223: Electric Pumps Catalogue

229

P.G

.A. -

DE

LTA

OIL

TABLE OF HYDRAULIC PERFORMANCE

P.G.A. - DELTA OIL

PUMP PERFORMANCE

MODELCODE

Absorbedpower

kWHPVOLTAGE Amp. F. Q

L/1’

m3/h

10 15 25 35 45 60Nominalpower

kWHP 0,6 0,9 1,5 2,1 2,7 3,6

5

0,3

ACCESSORIES

ZA000840 4 M SUCTION KIT

ZA005380 4 M DELIVERY KIT PIPE AND GUN

ZA000120 VOLUMETRIC METER PLASTC CASE

ZA005160 VOLUMETRIC METER ALUMINIUM CASE

ZA000130 ALUMINIUM DELIVERY GUN WITH RUBBER HOLDER 19 mm fl

TABLE OF SIZES AND WEIGHTS

ModelDimensions mm.

A

Weight

B C DNA DNM kgD E

141 255 20 120 119 3/4" 6,2 PGA 40 - 30

PGA 60 - 40

DELTA OIL

148

141

260

255

24

20

120

120

123

119

1"

3/4"

3/4"

1"

3/4"

8

7

P.G.A.60-40

P.G.A.40 -30 / DELTA OIL

150,9

301,8

452,7

603,6

75 4,5

50

40

30

20

10

HmL / 1’

m3/ hQ

PGA 40 - 30 M PGA 40 - 30 T 28

N6232090 N6232100 0,6 0,45

1 ~ 220 ˚240 V3 ~ 230 ˚400 V0,75 0,55 23 18

390,8 0,6 1,2 0,9 34 32

280,6 0,45 0,75 0,55 23 18 13 N6232170 DELTA OIL 1 ~ 220 ˚240 V

13

25 18

5

PGA 60 - 40 M PGA 60 - 40 T

N6232130 N6232140

1 ~ 220 ˚240 V3 ~ 230 ˚400 V

5

12 1

2,71,6-0,9

2,7

4,52,7-1,6

8

8

12,5

4 M SUCTION KIT 4 M DELIVERY KITPIPE AND GUN

V O L U M E T R I CLITRE-COUNTER

Dis

char

gehe

adin

met

ers

Page 224: Electric Pumps Catalogue

VERSAILLESSUBMERSIBLE PUMPS FOR FOUNTAINS ANDWATER FEATURES

The VERSAILLES pumps have been designed for fountains, water features and waterfallsin water gardens.

230

Motor- Dry motor with stainless steel casing- Level of protection IP68- Class F insulation- Single phase power supply with capacitor permanently activated- Thermal protection built into the motor winding- Completely insulated cable connection chamber- Self-lubricating ball bearings- Speed of rotation 2850 rpm- Suitable for continuous use

Usage limitations- Type of liquid: clear water, free of solids- Maximum liquid temperature 40¡C- Maximum submersion under the water level 7m- Free clearance: 1,5mm. For water features with a less clearance insert the sponge filter (optional) in the hydraulics

Applications- For fountains, water features, waterfalls in water gardens

Component

Suction grid

Base

Impeller

Power cable

Seal

Motor shaft

Material

X 5 CrNi 1810 (AISI 304) Stainless steel

X 5 CrNi 1810 (AISI 304) Stainless steel

10 m H07 RN-F With plug

DESIGN FEATURES

Pump casing

Fixed double NBR 70 rubber sealwith special sand guard V-ring

X 12 CrS 13 (AISI 416) Withceramic facing at the points of wear

X 5 CrNi 1810 (AISI 304) Stainless steel

X 5 CrNi 1810 (AISI 304) Die cast stainless steel

1 F reducer Plastic

SPARE FILTER

Accessories (optional)- Vulcano: adjustable water feature with three level jets- Gaiser: adjustable water feature with a single foamy jet- Campana: adjustable bell-shaped water feature- Filters: sponge to be used for water features with clearances under 1.5 mm

Page 225: Electric Pumps Catalogue

231

VE

RSA

ILLE

S

TABLE OF HYDRAULIC PERFORMANCE

VERSAILLES

PUMP PERFORMANCE

MODELCODE

Absorbedpower

kWVOLTAGE Amp. F. Q l /1

HP kW HP

Nominalpower

TABLE OF SIZES AND WEIGHTS

ModelDimensions mm.

A

Weight

B C DNM kgP.L.

VERSAILLES 160/8

VERSAILLES 250/10

144

285

231

372

425

620

fl 1,5

fl 1,5

1 1/4

1 1/4

7

7,8

VERSAILLES 350/12 285 372 620 fl 1,5 1 1/4 9,3

N2121010

N2121020

N2121030

ZB401690

ZB401700

ZB401710

ZB401720

ZB401730

VERSAILLES 160/8

VERSAILLES 250/10

VERSAILLES 350/12

VULCANO

GAISER

CAMPANA

FILTER 1 FOR MOD. 80/7 - 160/8

FILTER 2 FOR MOD. 250/10 - 350/12

Diameter and height of water featuresin cm

VULCANO GAISER CAMPANA

0,6 0,450,5 0,37

1,2 0,90,75 0,55

1,6 1,21,1 0,8

1 ~ 220 ˚240 V

1 ~ 220 ˚240 V

1 ~ 220 ˚240 V

2,2

4,5

5,1

8

10

16

fl 180 - H 360

fl 200 - H 420

fl 200 - H 480

fl 20 - H 110

fl 30 - H 180

fl 50 - H 230

fl 90 - H 45

fl 95 - H 45

fl 100 - H 45

Hm

12

L / 1’m3/ h

Q 50 100 150 200 250 300

3 6 9 12 15 18

10

8

6

4

2

350/12

160/8

250/10

Dis

char

gehe

adin

met

ers

Page 226: Electric Pumps Catalogue

VERSAILLES

232

CAMPANA

GAISER

VULCANO

Page 227: Electric Pumps Catalogue

233

Pressure assembliesSIZING HOME WATER SYSTEMS

The fundamental data for selecting a pressure assemblie unit is:a) the water flow rate required at the moment of maximum usageb) the total delivery headThe flow rate required may be taken from the average statistical values diagram shownbelow (Fig. No. 1).The calculation of the total delivery head (which corresponds to the minimum unitworking pressure) provides for three different cases:A) supply from a deposit at the same level as the unitB) supply from a mains water supply system or deposit higher than the unitC) supply from a well or deposit situated lower than the unitCase A) The height of the highest sampling point is added to the pressure value requiredat that point plus any flow resistance. (See example Fig. No. 2)Case B) Proceed as per case A, then take from the figure obtained the actual pressurevalue of the water supply system or the pressure value developed as a result of thedrop from the deposit. (See example Fig. No. 3)Case C) Proceed as per case A, then add to the figure obtained the value in metresbetween the water level and the unit. (see Fig. No. 4)The figures obtained compared with the tables specifying the features of the differentautoclave units shown in the catalogue will allow the most suitable unit to be selected.You must consider that in these tables the highest minimum tap pressure provided foris 1.5 atm.The information outlined is of a general nature as the different specific conditions of usecannot be taken into consideration.

FLATS (2 wc) NUMBER OF PEOPLE

% CALCULATED CONTEMPORANEOUSNESS % CALCULATED CONTEMPORANEOUSNESS

CURVES FOR WC WITH FLUSH CISTERNS(FOR WC WITH FAST RATE FLUSHINGS + 30%)

5 6 7 8 9 10 12 14 16 18 20 30 40 60 80 100

OFF IC

ES

DEPARTEMENT

STORES

HOM

ES

HOTELS

IST IT

UT IO

NS

200

100

80

60

50

40

30

20

18

16

14

12

10

m3/h

17

20

30

43

50

57

60

63

66

500

300

200

150

100

50

60

65

70

75

80

Fig. 1

Page 228: Electric Pumps Catalogue

234

Pressure assemblies

HE = Building height 18 m.

CASE A

H building 18 +Minimum pressure 15 +Flow resistance 2 =

Meters 35

HE

Min. pressure 1,5 ATM

Deposit

HD =Deposit height 20 m.

HD

Min. pressure 1,5 ATM

Deposit

CASE B

Head necessary 35 -Mains water supply pressure 20 =

Meters 15

Pressure necessary 35 -The tank 20 =

Meters 15Public watersupply systempressure 2 ATM

HA

HA = Suction height 5 m.

Min. pressure 1,5 ATM

CASE C

Head necessary 35 +Suction height 5 =

Meters 40

Fig. 2

Fig. 3

Fig. 4

Page 229: Electric Pumps Catalogue

0,855

1,282

1,710

2,138

2,565

2,993

0,470

0,705

0,940

1,174

1,409

1,644

1,879

2,349

2,819

3,288

0,292

0,438

0,584

0,730

0,876

1,022

1,168

1,460

1,751

2,043

2,335

2,627

2,919

3,649

0,249

0,331

0,415

0,498

0,581

0,664

0,830

0,996

1,162

1,328

1,494

1,660

2,075

2,490

2,904

3,319

4,149

0,249

0,312

0,374

0,436

0,499

0,623

0,748

0,873

0,997

1,122

1,247

1,558

1,870

2,182

2,493

3,117

3,740

4,987

0,231

0,269

0,308

0,385

0,462

0,539

0,616

0,693

0,770

0,962

1,154

1,347

1,539

1,924

2,309

3,078

3,848

4,618

0,229

0,275

0,321

0,376

0,413

0,459

0,574

0,688

0,803

0,918

1,147

1,377

1,836

2,295

2,753

3,212

3,671

4,130

4,589

0,231

0,263

0,296

0,329

0,412

0,494

0,576

0,659

0,823

0,988

1,317

1,647

1,976

2,306

2,635

2,964

3,294

4,117

4,941

0,248

0,310

0,372

0,434

0,496

0,620

0,744

0,992

1,240

1,488

1,736

1,984

2,232

2,480

3,100

3,720

4,340

4,960

0,241

0,289

0,337

0,385

0,481

0,577

0,770

0,962

1,155

1,347

1,540

1,732

1,925

2,406

2,887

3,368

3,850

4,812

0,251

0,314

0,377

0,502

0,628

0,753

0,879

1,005

1,130

1,256

1,5701,883

2,197

2,511

3,139

3,767

5,023

0,263

0,351

0,439

0,526

0,614

0,702

0,790

0,877

1,097

1,316

1,535

1,754

2,193

2,632

3,509

4,386

0,084

0,126

0,175

0,294

0,445

0,623

0,831

1,066

1,328

1,616

2,458

3,458

4,665

5,995

9,216

13,05

22,72

0,074

0,124

0,187

0,260

0,347

0,445

0,555

0,674

1,027

1,444

1,934

2,496

3,807

5,417

8,926

14,42

0,101

0,140

0,184

0,234

0,350

0,488

0,829

1,254

1,757

2,345

3,009

3,762

4,595

7,010

9,892

13,30

17,16

26,26

235

Pressure assemblies

Pre

ssure

ass

em

blies

FLOW RESISTANCE AND WATER SPEED TABLE

N.B. - To evaluate the flow resistance in pipes made of different materials, the value found for the galvanisedpipe must be multiplied by the following set coefficients:0,6 for PVC pipes0,7 for aluminium pipes0,8 for rolled steel pipes1,3 for cement fibre pipes

m3/h lt./min. lt./sec.1/2" 3/4" 1" 1"1/4 1"1/2 2" 21/2" 3" 3"1/2 4" 5" 6"

15,75 21,25 27,00 35,75 41,25 52,50 68,00 80,25 92,50 105,0 130,0 155,5

FLOW RATEGALVANISED PIPES - NEW

NOMINAL DIAMETERS IN INCHES AND IN MILLIMETRES

0,6

0,9

1,2

1,5

1,8

2,1

2,4

3,0

3,6

4,2

4,8

5,4

6,0

7,5

9,0

10,5

12

15

18

24

30

36

42

48

54

60

75

90

105

120

150

180

240

300

10

15

20

25

30

35

40

50

60

70

80

90

100

125

150

175

200

250

300

400

500

600

700

800

900

1000

1250

1500

1750

2000

2500

3000

4000

5000

0,16

0,25

0,33

0,42

0,50

0,58

0,67

0,83

1,00

1,12

1,33

1,50

1,67

2,08

2,50

2,92

3,33

4,17

5,00

6,67

8,33

10,0

11,7

13,3

15,0

16,7

20,8

25,0

29,2

33,3

41,7

50,0

66,7

83,3

9,910

20,11

33,53

49,93

69,34

91,54

2,407

4,862

8,035

11,91

16,50

21,75

27,66

41,40

57,74

76,49

0,784

1,570

2,588

3,834

5,277

6,949

8,820

13,14

18,28

24,18

30,87

38,30

46,49

70,41

0,346

0,510

0,700

0,914

1,1160

1,719

2,375

3,132

3,988

4,927

5,972

8,967

12,53

16,66

21,36

32,32

45,52

78,17

0,223

0,291

0,368

0,544

0,751

0,988

1,254

1,551

1,875

2,802

3,903

5,179

6,624

10,03

14,04

24,04

36,71

51,84

0,159

0,218

0,287

0,363

0,449

0,542

0,809

1,124

1,488

1,901

2,860

4,009

6,828

10,40

14,62

19,52

25,20

31,51

38,43

0,131

0,164

0,203

0,244

0,365

0,506

0,670

0,855

1,282

1,792

3,053

4,622

6,505

8,693

11,18

13,97

17,06

26,10

36,97

0,124

0,185

0,256

0,338

0,431

0,646

0,903

1,530

2,315

3,261

4,356

5,582

6,983

8,521

13,00

18,42

24,76

31,94

Large numbers: Flow resistancein m for every 100 m of piping

Small numbers: Water speed inmetres per second

0,416

0,677

1,004

1,379

1,811

2,290

3,403

4,718

6,231

7,940

9,828

11,90

17,93

25,11

33,32

42,75

64,86

Page 230: Electric Pumps Catalogue

AUTOJETBOOSTER SET WITH ELECTRONIC CONTROLAND PROTECTION DEVICE

236

Automatic booster set designed to increase home water pressure.Made up of a single phase JETINOX pump and of a FLUSSCONTROL BASIC electronic controland dry running protection device.It is supplied wired, assembled, ready to use.

Design features– Flusscontrol Basic: Max. pressure 8 bar Max. operating temperature 40° C– Power supply cable: 1,5 m H07 RN-F with plug

Motor– Enclosed, externally ventilated– Level of protection: IP44– Class F insulation– Single phase power supply with capacitor permanently activated– Thermal protection built into the motor winding– Speed of rotation 2850 rpm– Suitable for continuous use

Usage limitations– Type of liquid: clean water with no suspended solids or abrasive material– Maximum liquid temperature 40° C– Maximum recommended suction height: 8m with foot valve– Maximum operating pressure: 8 bar

Applications– Pumping and distribution of water in domestic systems– Booster systems– Washing systems, irrigation

Advantages– Attenuates the effects of water hammering– Replaces the traditional expansion tank system– Maintenance-free– Protection from dry running– Easy to install– Maintains constant pressure during delivery

1

2

3

4

5

6

7

8

9

Pump casing

Motor bracket

ImpellerDiffuser - venturi tubeand nozzle

Shaft

Mechanical seal

Counterface

Seal holder plate

O’ring

X5 CrNi 1810 (AISI 304) Stainless steel

Die cast aluminium

Technopolymer with stainless steel shim ring

Technopolymer

X 12 CrNiS 1809 ( AISI 416 ) Stainless steel

Graphite

CeramicTechnopolymer (series 45-60-70)X5 CrNi 1810 ( AISI 304 ) stainless steel serie 90NBR 70 Shore

Design features

Component Material

Page 231: Electric Pumps Catalogue

20

1,2

40

2,4

60

3,6

80

4,8

Hm

L / 1'm3/ h

Q

20

10

30

40

50

60

60/50

70/50

237

AUTOJET

AU

TO

JE

T

1 ~ 230 VAUTOJET 60/50 0,75 0,55 0,81,10 12,5 46 N4176880-1 4

PUMP PERFORMANCE

MODELCODE

Absorbedpower

kWVOLTAGE

( V )Amp. µF. Q

L/1'

m3/hHP

1,36 1,0 480,95 0,7AUTOJET 70/50 N4176870-1 1 ~ 230 V 4,5 16

0

0,0kW HP

Nominalpower

36

42,5

10

0,6

31

37,5

20

1,2

26

32

30

1,8

18

25

40

2,4

6

16,5

50

3,0

7

60

3,6

TABLE OF SIZES AND WEIGHTS

ModelDimensions mm.

A

Weight

C kgB D DNA DNM

AUTOJET 70/50

AUTOJET 60/50

F

DN

A

A

D

DNM

B F

C

140

144

374

351

99

99

391

397

194

195

1” F

1” F

1” M

1” M

9,4

10,7

Dischargehead

in meters

TABLE OF HYDRAULIC PERFORMANCE

Page 232: Electric Pumps Catalogue

AUTOMAXBOOSTER SET WITH ELECTRONIC CONTROLAND PROTECTION DEVICE

238

Automatic booster set designed to increase home water pressure.Made up of a single phase JETINOX pump and of a FLUSSCONTROL BASIC electroniccontrol and dry running protection device.It is supplied wired, assembled, ready to use.

Design features– Flusscontrol Basic: Max. pressure 8 bar Max. operating temperature 40° C– Power supply cable: 1,5 m H07 RN-F with plug

Motor– Enclosed, externally ventilated– Level of protection: IP44– Class F insulation– Single phase power supply with capacitor permanently activated– Thermal protection built into the motor winding– Speed of rotation 2850 rpm– Suitable for continuous use

Usage limitations– Type of liquid: clean water with no suspended solids or abrasive material– Maximum liquid temperature 40° C– Maximum recommended suction height: 7m with foot valve– Maximum operating pressure: 8 bar

– Pumping and distribution of water in domestic systems– Booster systems– Washing systems, irrigation

Advantages– Attenuates the effects of water hammering– Replaces the traditional expansion tank system– Maintenance-free– Protection from dry running– Easy to install– Maintains constant pressure during delivery

Applications

Component

Pump casing

Motor bracket

Shaft

Mechanical seal

Counterface

O’ ring

Material

X5 CrNi 1810 (AISI 304) Stainless steel

Die cast aluminium

X5 CrNi 1810 (AISI 304) Stainless steel

Graphite

Design features

Seal holder plate

DiffuserVenturi tube and Nozzle Technopolymer

12

3 Impeller Technopolymer with X5 CrNi 1810 (AISI 304)stainless steel shim ring

4

5

Ceramic

67

NBR 70 shore

Noryl GFN2V

8

9

Spacer Nickel plated brass OT 58

10

Page 233: Electric Pumps Catalogue

239

AUTOMAX

AU

TO

MA

X

20

1,2

40

2,4

60

3,6

80

4,8

120

7,2

100

6

Hm

L / 1'm3/ h

Q

20

10

30

40

50

60

1 ~ 230 VAUTOMAX 80/48 0,75 0,55 0,81,1 12,5 45N4501170-B1 4

PUMP PERFORMANCE

MODELCOD

Absorbedpower

kWVOLTAGE

( V )Amp. µF. Q

L/1'

m3/hHP

1,7 1,25 601,2 0,9AUTOMAX 120/60N4501180-B1 1 ~ 230 V 5,8 20

0

0,0kW HP

Nominalpower

TABLE OF SIZES AND WEIGHTS

ModelDimensions mm.

A

Weight

C kgB D DNA DNM

AUTOMAX 120/60

AUTOMAX 80/48

80/48

120/60

36

55

20

1,2

28

48

40

2,4

17

36

60

3,6

1

26

80

4,8

F

129

129

370

415

99

99

380

390

205

205

1” F

1” F

1” M

1” M

9,2

12,2

Dischargehead

in meters

DN

A

A

D

DNM

B F

C

TABLE OF HYDRAULIC PERFORMANCE

Page 234: Electric Pumps Catalogue

WATERPRESSBOOSTER SETS WITH 24L HORIZONTALEXPANSION TANK

The WATERPRESS booster sets are made up of JET self-priming centrifugal pumps.They are supplied wired, tested and complete with 24l expansion tank. Ready to use.

240

Motor-Enclosed, externally ventilated-Level of protection IP44-Class F insulation-Single phase power supply with capacitor permanently activated-Thermal protection built into the motor winding-Speed of rotation 2850 rpm-Suitable for continuous use

Applications- Pumping and distribution of water in domestic systems- Booster systems- Washing systems and irrigation

Usage limitations- Type of liquid: clean water with no suspended solids or abrasive material- Maximum liquid temperature 50° C- Maximum suction height 8m with foot valve- Maximum operating pressure 6 bar

Design features– Pressure switch (max 6 bar) calibrated at: min 2 - max 3 bar– Pressure gauge (6 bar)– Chromium plated pressed brass 3 way fitting (model Waterpress 70/50)– 24Lt painted steel expansion tank with interchangeable food quality rubber diaphragm.– Flexible pipe for water connection– 1,5 m H05 RN-F power supply cable with plug

Component

Pump casing

Motor bracket

DiffuserVenturi tube - nozzle

Mechanical seal

Counterface

O’ring

Material

EN GJL 200 ( ex G20 ) Cast iron

Aluminium

Graphite

Design features

Impeller

Ceramic

NBR 70 shore

Technopolymer withX5 CrNi 1810 ( Aisi 304 )stainless steel shim ring

WATERPRESS 70/50WATERPRESS 40/40 - 60/50EN GJL 200 ( ex G20 )Cast iron

EN GJL 200 ( ex G20 )Cast iron

Technopolymer

Monobloc technopolymerassembly Technopolymer

Motor shaft X5 CrNi 1810( AISI 304 ) Stainless steel

X 12 CrNiS 1809( AISI 416 ) Stainless steel

Graphite

Ceramic

NBR 70 shore

Page 235: Electric Pumps Catalogue

241

WATE

RP

RE

SS

TABLE OF HYDRAULIC PERFORMANCE

WATERPRESS

TABLE OF SIZES AND WEIGHTS

ModelDimensions mm.

A

Weight

C kgB D DNA DNM

22,31" F 1" FWATERPRESS 70/50 520 460 550 315

Hm

20

10

30

40

50

MODELCODE

Absorbedpower

kWHPVOLTAGE Amp. µF. Q

L/1'

m3/h

0 10 20 30 40 50 60Nominalpower

kWHP 0,3 1,2 1,8 2,4 3 3,6

70

4,2

1 ~ 220 ÷ 240 V WATERPRESS 60/50 N5209160 461,1 0,8 36 31 24 9 40,75 0,55 4 10

5 N5209730 WATERPRESS 70/50 1 ~ 220 ÷ 240 V

0

501,5 1,1 46 41 37 321,36 1 28 18 316

20

1,2

L / 1'm3/ h

Q 10

0,6

30

1,8

40

2,4

50

3

60

3,6

70

4,2

80

4,8

14,51" F 1" FWATERPRESS 60/50 510 430 470 260

1 ~ 220 ÷ 240 V WATERPRESS 40/40 N5209780 410,8 0,6 28 21 80,5 0,37 3 6

13,71" F 1" FWATERPRESS 40/40 510 430 470 260

PUMP PERFORMANCE

Dischargehead

in meters

Page 236: Electric Pumps Catalogue

WATERPRESS INOXBOOSTER SET WITH 24 LtHORIZONTAL EXPANSION TANK

The WATERPRESS INOX booster sets are produced with JETINOX or MAX pumps.They are supplied wired, complete with 24 lt expansion tank, ready to use.

242

Motor– Enclosed, externally ventilated– Level of protection: IP44– Class insulation: F– Single phase power supply with capacitor permanently activated.– Thermal protection built into the motor winding– Speed of rotation: 2850 rpm.– Suitable for continuous use.

Applications- Pumping and distribution of water in domestic systems- Booster systems- Washing systems and irrigation

Usage limitations– Type of liquid: clean water with no suspended solids or abrasive materials– Maximum liquid temperature: 50°C– Maximum suction height 8 m with foot valve (7m for WATERPRESS INOX 80/48)– Maximum operating pressure: 6 bar

Pump casing

Motor bracket

Impellers

Diffuser

Shaft (hydraulic end)

Mechanical seal

Counterface

Seal plate

O'ring

X 5 CrNi 1810 (AISI 304) Stainless steel

Die cast aluminium

Technopolymerwith stainless steel shim ringTechnopolymer

X 5 CrNi 1810 (AISI 304) Stainless steel

Graphite

Ceramic

Technopolymer

NBR 70 Shore

Component Material

DESIGN FEATURES WP INOX 80/48

Pump casing

Motor bracket

Impellers

Monobloc diffusor- Venturitube - nozzle assemblyShaft

Mechanical seal

Counterface

Seal plate

O'ring

X 5 CrNi 1810 (AISI 304) Stainless steel

Die cast aluminium

Technopolymerwith stainless steel shim ring

Technopolymer

X 12 CrNiS 1809 (AISI 416) Stainless steel

Graphite

Ceramic

Technopolymer

NBR 70 Shore

Component Material

DESIGN FEATURES WP INOX 70/50

Design features– Pressure switch (max 6 bar) calibrated at: min 2 ÷ max 3 bar– Pressure gauge (6 bar)– Chromium plated pressed brass 5 way fitting– 24Lt painted steel expansion tank with interchangeable food quality rubber diaphragm.– Flexible pipe for water connection– 1,5 m H05 RN-F power supply cable with plug

Page 237: Electric Pumps Catalogue

243

WA

TE

RP

RE

SS IN

OX

WATERPRESS INOX

TABLE OF SIZES AND WEIGHTS

ModelDimensions mm.

A

Weight

C kgB D DNA DNM

12,31" F 1" F

WATERPRESS INOX 70/50

520 430 550 260

1 ~ 230 VWP INOX 70/50 0,95 0,7 1,01,36 16 37,5 25 7 N5209750 4,5 48

PUMP PERFORMANCE

MODELCODE

Absorbedpower

kWVOLTAGE Amp. µF. Q

L/1'

m3/h

0

HP

WATERPRESS INOX 80/48

13,81" F 1" F520 445 565 260

TABLE OF HYDRAULIC PERFORMANCE

Hm

20

10

30

40

50

70 /50

20

1,2

L / 1'm3/ h

Q 10

0,6

30

1,8

40

2,4

50

3

60

3,6

70

4,2

80

4,8

60

1,1 0,8 36 28 17 10,75 0,55 WP INOX 80/48 N5301110 1 ~ 230 V 454 12,5

0

60

3,6

80

4,8

20

1,2

40

2,4kW HP

Nominalpower

Dischargehead

in meters

Page 238: Electric Pumps Catalogue

WATERPRESS INOX 50 LBOOSTER SET WITH 50 Lt HORIZONTALEXPANSION TANK

The WATERPRESS INOX 50 L is a booster set produced with MAX self-priming multistagecentrifugal pump. It is supplied wired, complete with 50 Lt expansion tank, ready touse.

244

Motor- Enclosed, externally ventilated- Level of protection IP44- Class F insulation- Single phase power supply with capacitor permanently activated- Thermal protection built into the motor winding- Speed of rotation 2850 rpm- Suitable for continuous use

Component Material

DESIGN FEATURES

Design features WP INOX 80/48 - 50 L: electromechanical pressure switch (max 6 bar) set at min 2 ÷ max 3 bar WP INOX 120/60 - 50 L: electronic control and protection pressure switch AQUA TROL. Adjustable pump's starting pressure: from 1,5 to 3 bar.

– Pressure gauge (6 bar)– Chromium plated pressed brass 5 way fitting– 50 Lt painted steel expansion tank with interchangeable food quality rubber diaphragm.– Flexible pipe for water connection– 1,5 m H05 RN-F power supply cable with plug

Applications- Pumping and distribution of water in domestic systems- Booster systems- Washing systems and irrigation

Usage limitations- Type of liquid: clean water with no suspended solids or abrasive material- Maximum liquid temperature 50° C- Maximum suction height recommended 7 m with foot valve- Maximum operating pressure 7 bar

WP INOX 80/48 -50 Lt with AQUA TROLelectronic pressure switch

WP INOX 80/48 -50 Lt with electromechanicalpressure switch

Pump casing

Motor bracket

Impellers

Diffuser

Shaft (hydraulic end)

Mechanical seal

Counterface

Seal plate

O'ring

X 5 CrNi 1810 (AISI 304) Stainless steel

Die cast aluminium

Technopolymerwith stainless steel shim ringTechnopolymer

X 5 CrNi 1810 (AISI 304) Stainless steel

Graphite

Ceramic

Technopolymer

NBR 70 Shore

Page 239: Electric Pumps Catalogue

245

WA

TE

RP

RE

SS IN

OX

50 L

TABLE OF HYDRAULIC PERFORMANCE

WATERPRESS INOX 50 L

TABLE OF SIZES AND WEIGHTS

ModelDimensions mm.

A

Weight

C kgB D DNA DNM

5,8 201,25 36 260,9 60 N5301130 WP INOX 120 /60 1 ~ 230 ÷ 240 V

211" F 1" FWATERPRESS 120/60 640 520 640 370

55 48

80 / 48

PUMP PERFORMANCE

MODELCODE

Absorbedpower

kWVOLTAGE Amp. µF. Q

L/1'

m3/h

0

HP

1,2 1,7 20

WATERPRESS 80/48 181" F 1" F640 520 640 370

20

1,2

40

2,4

60

3,6

80

4,8

120

7,2

100

6Q

L / 1'm3/ h

Hm

20

10

30

40

50

60

1,1 0,8 36 28 17 10,75 0,55 WP INOX 80/48 N5301140 1 ~ 230 V 454 12,5

0

60

3,6

80

4,8

20

1,2

40

2,4kW HP

Nominalpower

Dischargehead

in meters

Page 240: Electric Pumps Catalogue

WATERPRESS SUPERINOXBOOSTER SET WITH 24 Lt HORIZONTALEXPANSION TANK

The WATERPRESS SUPERINOX is a booster set produced with JETINOX or MAX selfpriming centrifugal pump. It is supplied wired and complete with stainless steel expansiontank.

246

Motor- Enclosed, externally ventilated- Level of protection IP44- Class F insulation- Single phase power supply with capacitor permanently activated- Thermal protection built into the motor winding- Speed of rotation 2850 rpm- Suitable for continuous use

Applications- Pumping and distribution of water in domestic systems- Booster systems- Washing systems and irrigation

Usage limitations– Type of liquid: clean water with no suspended solids or abrasive materials– Maximum liquid temperature: 50°C– Maximum suction height with foot valve: 8 m WP Superinox 60/50 7 m WP Superinox 120/60– Maximum operating pressure: 6 bar WP Superinox 60/50 7 bar WP Superinox 120/60

Design features– Pressure switch (max. 6 bar) set at: min 2 ÷ max 3 bar– Pressure gauge (6 bar)– Chromium plated pressed brass 5 way fitting– 24 Lt stainless steel expansion tank with interchangeable food quality rub.– Flexible pipe for water connection.– 1,5 m H05 RN-F power supply cable with plug

Component Material

DESIGN FEATURES WP SUPERINOX 120/60

Component Material

DESIGN FEATURES WP SUPERINOX 60/50

Pump casing

Motor bracket

Impellers

Monobloc diffuserVenturi tube - nozzle assemblyShaft (hydraulic end)

Mechanical seal

Counterface

Seal plate

O'ring

X 5 CrNi 1810 (AISI 304) Stainless steel

Die cast aluminiumTechnopolymerwith stainless steel shim ring

Technopolymer

X 12 CrNiS 1809 (AISI 416) Stainless steel

Graphite

Ceramic

Technopolymer

NBR 70 Shore

Pump casing

Motor bracket

Impellers

Diffuser

Shaft (hydraulic end)

Mechanical seal

Counterface

Seal plate

O'ring

X 5 CrNi 1810 (AISI 304) Stainless steel

Die cast aluminium

Technopolymerwith stainless steel shim ringTechnopolymer

X 5 CrNi 1810 (AISI 304) Stainless steel

Graphite

Ceramic

Technopolymer

NBR 70 Shore

Page 241: Electric Pumps Catalogue

247

WATE

RP

RE

SS S

UP

ER

INO

X

WATERPRESS SUPERINOX

TABLE OF SIZES AND WEIGHTS

ModelDimensions mm.

A

Weight

C kg

PUMP PERFORMANCE

MODELCODE

Absorbedpower

kWHPVOLTAGE Amp. µF. Q

L/1'

m3/h

0Nominalpower

kWHP 0

40

2,4

60

3,6

80

4,8

B D DNA DNM

50

3

20

1,2

1 ~ 220 ÷ 240 V N5301150 1,7 1,25 55 48 44 361,2 0,9 60 WP SUPERINOX 120/60 C 265,8 20

WP SUPERINOX 120/60 C 530 14,2425 550 280 1" F 1" F

1 ~ 220 ÷ 240 V N5209680 1,1 0,8 31 18 60,75 0,55 46 WP SUPERINOX 60/50 C 4 12,5

WP SUPERINOX 60/50 C 530 11,2425 550 280 1" F 1" F

TABLE OF HYDRAULIC PERFORMANCE

120/60

Hm

20

10

30

40

50

60

20

1,2

40

2,4

60

3,6

80

4,8

120

7,2

100

6Q

L / 1'm3/ h

Dischargehead

in meters

Page 242: Electric Pumps Catalogue

PRESSOMAT RESIDENTIAL USEPRESSURE BOOSTER UNITS CONTROLLED BY PRESSURESWITCH

248

Pressure booster units equipped with single and three phase pumps for the automaticpressurization of water supply systems.

OperationThe pumps are controlled by two differential pressure switches with adjustable calibrationdue to the electric control panel supplied with SM electronic card for:– Sequential starting of the pumps– Changeover of starting order– Protection against dry running– Adjustable timing from 0 to 180 seconds (three phase version)

Discharge manifoldIn galvanized steel with:N.2 brass ball valvesN.1 manometerN.2 differential pressure switches

Suction manifoldIn galvanized steel with:N.2 brass ball valvesN.2 check valvesN.2 attachments for possible air feedersN.1 manifold for water loading

Basement- Galvanized iron

1~230V / 3~400V

50Hz

IP54

+40˚C

IP44 IP44 IP44

When the system pressure reaches the closing value of the electric contact of pressure switch n°1, the first pump starts. If the water consumption increases and the pressure goes down the second pump starts. When pressure increases the manostatsopen their contact switching off one of the pumps.At the end of each cycle, the automatic inverter changes the starting order of the pumps (at the first cycle pressure switch n° 1 is associated to pump n°1; the next cycle to pump n°2). In case of simultaneous closing of the two pressure switches, the electronic card delays the starting of the second pump avoiding strong pressure jolts and overload of the electric power supply.

Applications- Pumping of water in domestic systems- Booster systems- Washing systems and irrigation

Max. head (m.w.c)

Max. operating pressure(bar)

Frequency

Environmental temperature

Technical features

Power supply voltage

Protection degree-electric pumps

Protection degree-control panel

Max. flow (m3/h)

MULTINOX MULTINOXA

MULTINOXVE

12 19,2 19,2

58 77 107

9 99

12bar(mxv 200/100)

Page 243: Electric Pumps Catalogue

249

THREE PHASE ELECTRIC PANELPRESSOMAT

PR

ESSO

MAT

Electric panel- IP54 metallic case- General switch- Keyboard with SA electronic card- Fuses, manifold and thermal relay for each pump- Transformer with fuses for the auxiliary circuit- M-A selector for each pump

Main functions- Cyclic inversion of the starting order of the pumps after the end of every operation cycle- ON/OFF control of the level of the first gathering tank or of the pressure in the feeding pipe through a float switch or an inverse differential manostat.- Timing, adjustable from 0 to 180 seconds of the pumps operation after the manostat’s contact opens.

Signaling and commands- Led signaling the presence of electric power.- Led signaling low water level in the first gathering tank or insufficient pressure in the water feeding pipe (aqueduct).- One led signaling the operation status of each pump- Led signaling when one of the two thermal overload relay switches has been triggered- Leds signaling manual or automatic mode.- Buttons for choosing manual or automatic control.- Buttons to choose start or stop of each pump (when in manual mode)

External command devices- Two ON/OFF adjustable differential manostats

External control devices- ON/OFF float switch in the water gathering tank or- 3 electrodes for the electronic control of the first gathering tank level or- Inverse manostat inserted in the water feeding pipe (aqueduct)

Page 244: Electric Pumps Catalogue

PRESSOMATSINGLE PHASE ELECTRIC PANEL

250

Electric panel- IP55 metallic case- Magnetic-thermal main breaker- Fuses, manifold and thermal relay for each pump- Transformer with fuses for the auxiliary circuit- SML electronic card- Pump starting relay

Main functions- Cyclic inversion of the starting order of the pumps after the end of every operation cycle- ON/OFF control of the level of the first gathering tank or of the pressure in the feeding pipe through a float switch or an inverse differential manostat.

Signaling and commands- Led signaling the presence of electric power.- Led signaling low water level in the first gathering tank or insufficient pressure in the water feeding pipe (aqueduct).- One led signaling the operation status of each pump

External command devices- Two ON/OFF adjustable differential manostats

External control devices- ON/OFF float switch in the water gathering tank or- 3 electrodes for the electronic control of the first gathering tank level or- Inverse manostat inserted in the water feeding pipe (aqueduct)

Page 245: Electric Pumps Catalogue

PM.20/VA - MULTINOXTABLE OF HYDRAULIC PERFORMANCE

37

41

45

44

TYPE

Dimension mm.

TABLE OF SIZES AND WEIGHTS

45

Weight Kg

PM

.20/V

A -

MU

LTIN

OX

PM.20/VA-MULTINOX 80/36

PM.20/VA-MULTINOX 80/48

PM.20/VA-MULTINOX 80/60

PM.20/VA-MULTINOX 120/48

PM.20/VA-MULTINOX 120/60

L1

470

470

470

470

470

P1

600

620

640

620

640

H1

200

200

200

200

200

H2

360

360

360

360

360

H3DNA DNM L2

500

500

500

500

500

560

560

560

560

560

2”

2”

2”

2”

2”

2”

2”

2”

2”

2”

220

220

220

220

220

220V 400V

31

35

39

38

39

400V220V

40 80 120 160 200 240

2,4 4,8 7,2 9,6 12 14,4

10

20

30

40

50

60

70

PM.20/VA-MULTINOX 80/36 2x0,45 33 28 22 15 7

PM.20/VA-MULTINOX 80/48 2x0,55 43 37 29 20 9

PM.20/VA-MULTINOX 80/60 2x0,75 57 51 42 30 15

PM.20/VA-MULTINOX 120/48 2x0,75 48 43 37 29 20 4

PM.20/VA-MULTINOX 120/60 2x0,9 58 53 46 36 25 4

KWL / 1’

m3 / hTYPE

PUMP PERFORMANCE

PM.20/VA-MULTINOX 80/36

PM.20/VA-MULTINOX 80/48

PM.20/VA-MULTINOX 120/48

PM.20/VA-MULTINOX 120/60PM.20/VA-MULTINOX 80/60

251

Hm

L / 1'm3/ h

Q

0 2,4 4,8 7,2 9,6 12

0 40 80 120 160 200

H2

H1

H3

L2

L1

D2

D1

P1

Dis

charg

e h

ead

in m

ete

rs

Page 246: Electric Pumps Catalogue

PM.20/VA - MULTINOX-ATABLE OF HYDRAULIC PERFORMANCE

55

59

63

67

TYPE

Dimension mm.

TABLE OF SIZES AND WEIGHTS

Weight KgL1

580

580

P1

670

700

730

760

H1

200

200

200

200

H2

420

420

420

420

H3DNA DNM L2

560

560

620

620

620

620

2”

2”

2”

2”

2”

2”

2”

2”

220

220

220

220

220V 400V49

53

400V220VPM.20/VA-MULTINOX-A 200/40

PM.20/VA-MULTINOX-A 200/52

PM.20/VA-MULTINOX-A 200/65

PM.20/VA-MULTINOX-A 200/80

470

470

470

470

220V 400V

H2

H1

H3

L2

L1

D2

D1

P1

252

PM.20/VA-MULTINOX-A 200/40 2x1,1 35 34 33 30 25 15

PM.20/VA-MULTINOX-A 200/52 2x1,3 46 45 44 40 33 23

PM.20/VA-MULTINOX-A 200/65 2x1,4 59 58 54 49 41 30

PM.20/VA-MULTINOX-A 200/80 2x1,8 70 69 66 60 50 35

TYPE

PUMP PERFORMANCE

L / 1’

m3 / hKW

13

17,5

22

26

21,6

360

40 80 120 160 200 240

2,4 4,8 7,2 9,6 12 14,4

10

20

30

40

50

60

70

80

90

280 320 400

16,8 19,2 24

PM.20/VA-MULTINOX-A 200/80PM.20/VA-MULTINOX-A 200/65PM.20/VA-MULTINOX-A 200/52PM.20/VA-MULTINOX-A 200/40

360

21,6

Hm

L / 1'm3/ h

Q

0 2,4 4,8 9,6 14,4 19,2

0 40 80 160 240 320

Dis

charg

e h

ead

in m

ete

rs

Page 247: Electric Pumps Catalogue

PM.20/VA - MULTINOX-VETABLE OF HYDRAULIC PERFORMANCE

PM

.20/V

A-

MU

LTIN

OX

-VE

79

83

87

91

TYPE

Dimension mm.

TABLE OF SIZES AND WEIGHTS

109

Weight KgL1

580

580

580

580

580

P1

590

590

590

590

590

H1

67

67

67

67

67

H2

174

203

230

257

320

H3DNA DNM L2

775 800

800

800

800

800

2”1/2

2”1/2

2”1/2

2”1/2

2”1/2

2”

2”

2”

2”

2”

370

370

370

370

370

220V 400V

73

400V220V

75580 590 67 143 775 800 2”1/2 2” 370 69PM.20/VA-MULTINOX-VE 200/40

PM.20/VA-MULTINOX-VE 200/52

PM.20/VA-MULTINOX-VE 200/65

PM.20/VA-MULTINOX-VE 200/80

PM.20/VA-MULTINOX-VE 200/90

PM.20/VA-MULTINOX-VE 200/110

253

DNM

DNA H2

H1

P1

H3

L2L1

PM.20/VA-MULTINOX-VE 200/40 2x1,1

PM.20/VA-MULTINOX-VE 200/52 2x1,3

PM.20/VA-MULTINOX-VE 200/65 2x1,4

PM.20/VA-MULTINOX-VE 200/80 2x1,8

KWTYPE

PUMP PERFORMANCE

PM.20/VA-MULTINOX-VE 200/90 2x1,9 80 79 78 70 59 41

PM.20/VA-MULTINOX-VE 200/110 2x2,6 105 101 100 90 74 53

PM.20/VA-MULTINOX-VE 200/110PM.20/VA-MULTINOX-VE 200/90PM.20/VA-MULTINOX-VE 200/80PM.20/VA-MULTINOX-VE 200/65PM.20/VA-MULTINOX-VE 200/52PM.20/VA-MULTINOX-VE 200/40

L / 1’

m3 / h 0 2,4 4,8 9,6 14,4 19,2

0 40 80 160 240 320

Dis

charg

e h

ead

in m

ete

rs

35 34 33 30 25 15

46 45 44 40 33 23

59 58 54 49 41 30

70 69 66 60 50 35

13

17,5

22

26

21,6

360

30

39

40 80 120 160 200 2402,4 4,8 7,2 9,6 12 14,4

10

20

30

40

50

60

70

80

90

280 320 40016,8 19,2 24

36021,6

100

110

Hm

L / 1'm3/ h

Q

Page 248: Electric Pumps Catalogue

55

75

112

153

178

235

328

WM0060

WM0075

WM0120

WM0150

WM0180

WM0235

WM0330

453

606

757

1022

WM0450

WM0600

WM-IN-750

WM-IN-1000

Note: Maximum external operating temperature 120°F (49°C). Maximum internal operating temperature 100°F (38°C). Minimum operating temperature 40°F (4°C).* With minimum and maximum system pressure between 2,0 and 3,5 bar

*Diameter, height and weight may vary slightly without notice.

TECHNICAL FEATURES

VOLUMElt

CODE

18,3

25

37,3

50,9

59,3

78,3

109,2

150,8

201,8

252,1

340,3

8,5

8,5

8,5

8,5

8,5

8,5

8,5

8,5

10

10

10

1” M NPT

1” M NPT

1” M NPT

1” M NPT

1”1/4 M NPT

1”1/4 M NPT

1”1/4 M NPT

1”1/4 M NPT

2” M BSP

2” M BSP

2” M BSP

WM0060

WM0075

WM0120

WM0150

WM0180

WM0235

WM0330

WM0450

WM0600

WM-IN-750

WM-IN-1000

41

41

41

53

61

61

61

76

76

92

WM0060 41

81

112

145

105

105

140

189

174

206

212

66

4,4

4,4

4,4

5,7

5,7

5,7

5,7

15

15

20

4,4

8,1

11,2

13,6

19,5

22,7

33,0

43,1

76,2

89,0

117,1

6,6

WELLMATE TANKS

254

Wellmate tanks in composite material represent the best solution for pressurized water storage and pressureboostingapplications. Thanks to the high density polyethylene inner liner and to the fiberglass-wound and epoxy resin-sealed outershell, Wellmate tanks don't rust,require little maintenance and weigh half then an equivalent steel tank. All Wellmate vesselsare tested and certified by NSF International and produced according to the European Pressure Equipment Directive (PED)97/23/EC.

height* Outlet height to floor*Diameter*

TABLE OF SIZES AND WEIGHTS

CODE

Dimension (cm)weight*

Kg

REAL WATERVOLUME

(DRAWDOWN SETTING)*

MAXIMUMOPERATING

PRESSURE (BAR)CONNECTIONS

IN COMPOSITE MATERIAL

CODE MODELWM-PB-001 PUMP BASEMENT

Page 249: Electric Pumps Catalogue

255

EXPANSION TANKS

UPRIGHT VERSIONInterchangeable bromobutyl diaphragm,and capacities of 8-20-24 litres.The latter version is also available withoutdiaphragm with an air feeder.Preload: 1,5 bar

HORIZONTAL VERSION24- litres diaphragm with assemblybracket for the electric pump and a newsupport foot, designed to ensuremaximum stability.Preload: 1,5 bar

NOCCHI expansion tanks are made of AISI 304 stainless steel and are available in several models that are able to meet all thedemand of civil and industrial plants.No toxic replaceable bladder suitable for food use, particularly recommended for use in humid environments.In compliance with EC standards.

N 8

N 20

N 24

N 24 H

VAA 24

V 20

SB 20

VES INOX N 8

VES INOX N 20

VES INOX N 24

VES INOX N 24 H

VAA 24

FLEXINOX V 20

FLEXINOX SB 20

ZA006450

ZA006460

ZA006570

ZA006470

ZA006610

D3114KKK

D3104KKK

Ø B C DA

TABLE OF SIZES AND WEIGHTS

ModelDimensions mm. Weight

Kg

280 226 1”- 2,4

390 272 1”- 3,3

430 272 1”- 5,0

430 272 1”300 4,2

430 272 1”443 4,2

430 272 1”- 3,3

430 272 1”- 3,3

PERFORMANCE

MODELCODE DESCRIPTION DIAPHGRAM Assemblybracket

Max. operatingpreassure

( bar )

CapacityLt

VERTICAL 8 LT STAINLESS STEEL EXPANSION TANK

VERTICAL 20 LT STAINLESS STEEL EXPANSION TANK

VERTICAL 24 LT STAINLESS STEEL EXPANSION TANK

HORIZONTAL 24 LT STAINLESS STEEL EXPANSION TANK

24 LITRE STAINLESS STEEL TANK FOR AIR FEEDER

FLEXINOX 87 EXPANSION TANK - 20 LITER VERTICAL

FLEXINOX 87 EXPANSION TANK - 20 LITER S/B

BROMOBUTYL

BROMOBUTYL

BROMOBUTYL

BROMOBUTYL

-

BROMOBUTYL

BROMOBUTYL

-

-

-

-

YES

-

YES

8

8

8

8

8

10

10

8

20

24

24

24

24

24

Ø B

A

A

C Ø B

A

Ø B

DD

D

STAINLESS STEEL

Page 250: Electric Pumps Catalogue

EXPANSION TANKS

256

VES 2

VES 24 V

VES 24 H

VEC 60 H

VEC 60 V

VEC 100 H

VEC 100 V

ZA003860

ZA000140

ZA003850

ZA009120-CE

ZA009070-CE

ZA009130-CE

ZA009080-CE

PUMP PERFORMANCE

MODELCODE DESCRIPTION DIAPHGRAM Assemblybracket

6

6

6

10

10

10

10

2

24

24

60

60

100

100

ZA009090-CE

ZA009100-CE

ZA009110-CE

VEC 200 V

VEC 300 V

VEC 500 V

-

-

YES

200

300

500

10

10

10

Ø B DCA

TABLE OF SIZES AND WEIGHTS

ModelloDimensioni mm. Kg

415

680

845

780

950

VES 2

VES 24 V

VES 24 H

VEC 60 H

VEC 60 V

VEC 100 H

VEC 100 V

VEC 200 V

VEC 300 V

VEC 500 V

1225

1405

1550

155

-

1” M

1” M

1” M

1” M

1” M

1” 1/2 M

1” 1/2 M

1” 1/2 M

1” M

1” M

-

382

-

450

-

-

-

-

-

310415

-

382

-

450

550

630

780

175

295

17

17,5

18

19

37

54

104

4,1

0,950

4,8

Expansion tank for pressure assemblies, in painted steel, from 2 to 500 Lt.,with interchangeable diaphragm.Stainless steel painted carbon flange. CE certificate.Preload: 1.5 bar for models from 2 to 24 Lt. 2.0 bar for models from 60 to 500 Lt.In compliance with EC standards

A

Ø B

D

A

C Ø BD

A

Ø B

Max. operatingpressure

( bar )

CapacityLt

2 LITER EXPANSION TANK

VERTICAL 24 LITER EXPANSION TANK

HORIZONTAL 24 LITER EXPANSION TANK

HORIZONTAL 60 LITER EXPANSION TANK

VERTICAL 60 LITER EXPANSION TANK

HORIZONTAL 100 LITER EXPANSION TANK

VERTICAL 100 LITER EXPANSION TANK

VERTICAL 200 LITER EXPANSION TANK

VERTICAL 300 LITER EXPANSION TANK

VERTICAL 500 LITER EXPANSION TANK

Food - quality rubber

Food - quality rubber

Food - quality rubber

Butyl rubber

Butyl rubber

Butyl rubber

Butyl rubber

Butyl rubber

Butyl rubber

Butyl rubber

YES

YES

YES

YES

YES

YES

YES

PAINTED STEEL

Page 251: Electric Pumps Catalogue

257

ELECTRONIC CONTROL AND PROTECTION DEVICES

Page 252: Electric Pumps Catalogue

Protection Devices– Dry running– Amperometric– Overcurrent– Overtemperature of the electronics

Applications– Irrigation– Industry– Hotel installations– Buildings- Washing systems

VSD

VSD is able to modify the electropump frequency in order to grant the requesteddelivery maintaining a constant pressure.The setting is possible thanks to a pressuresensor and a flow sensor connected to the inverter. The constant pressure grantsa considerable energy saving and excellent performances. VSD range is availablein three versions:- VSD1 Basic (max 4.5 Amp.)- VSD1 (max 9.3 Amp.)- VSD3 (max 13.3 Amp.)

258

VARIABLE SPEED DRIVE

• EASY TO INSTALL

• CYCLICAL CHANGEOVER OF PUMPS IF USED IN TWIN-PUMP UNITS (VSD1/VSD3)

• POSSIBILITY OF 2 SET POINTS (VSD1 / VSD3)

The display indicates– Pump working frequency– Instant pressure– Absorbed power– Alarms

Page 253: Electric Pumps Catalogue

259

VSD

VSDVARIABLE SPEED DRIVE

ZB902170 VSD1Basic 22 28 18 3.4

Dimension (cm)

LWeight

kg.MODELCODE

H P

VSD1 basic and VSD1 are 1X230V single phase devices, able to modulate the speed of a three-phase pump (3X230V)keeping constant pressure in the system. VSD3 is a 3X400V three-phases device able to modulate the speed of athree-phase pump (3X400V). 2 set points system (on VSD1 and VSD3).

DIMENSIONS AND WEIGHTS

ZB902180 VSD1 22 28 18 3.8

ZB902190 VSD3 22 28 18 3.6

174 LP

1”1/4 M

1”1/2 F

H

TECHNICAL FEATURES

VSD 1 Basic

VSD 1

VSD 3

4,5

9,3

13,3

1x230

1x230

3x400

3x230

3x230

3x400

45° C

45° C

45° C

1÷9

1÷9

1÷9

1”1/4M

1”1/4M

1”1/4M

1”1/2F

1”1/2F

1”1/2F

IP 55

IP 55

IP 55

1

2

2

-

2 (fault; pumprunning)

2 (fault; pumprunning)

-

Float switch,second set

point selection

Float switch,second set

point selection

-

SerialinterfaceRS 485

SerialinterfaceRS 485

MODEL

Maxmotor

currentAmp.

Powersupplyvoltage

V

Electropumpvoltage

V

Liquidtemp.

Pressure regulation rangeBarDNA DNM Protection

levelSet

pointOptional contactsDigital

inputsConnections

WORKING POSITIONS

Whole range VSD1 Basic / VSD1

Max operating pressureBar

10

10

10

Page 254: Electric Pumps Catalogue

260

VSD1 mono 4.3VARIABLE SPEED DRIVE

Technical Features- Max motor current 4.3 Amp.- Power supply voltage 1X230 V- Electropump voltage 1X230 V- Liquid temperature 50° C- Max operating pressure 8 bar- Pressure regulation range 1÷3.6 Bar- Set point 1- Inlet 1” 1/4 M (male)- Outlet 1” 1/2 F (female)- Protection degree IP55

Protection Devices- Dry running- Overcurrent- Overtemperature of the electronics

Working Position

ZB902330 VSD1 mono 4.3 22 28 18 3.7

VSD1mono is a variable frequency drive control system for electrical water pump consist of: a built in pressure sensor, a flowsensor and an inverter all in a unique box. VSD1mono can work with any kind of pump: multi stage / single stage pump, surfaceor submersible pump. VSD1mono are factory provided with cables. VSD1mono uses the built in inverter to controls the speedof the motor maintaining a constant pressure in the plants. When the flow increases, he speed of the motor increase maintainingalways a constant pressure.

• COMPACT SIZE• HIGH RELIABILITY• EXTREMELY SILENT

Applications- Irrigation- Industry- Hotel installations- Buildings- Washing systems

DIMENSIONS AND WEIGHTS

L H P

174 L

P

1”1/4 M

1”1/2 F

H

Dimensions mm. Weightkg.ModelCode

Page 255: Electric Pumps Catalogue

261

VSD

1 m

ono

VSD1 mono 8.5VARIABLE SPEED DRIVE

Technical Features- Max motor current 8.5 Amp.- Power supply voltage 1X230 V- Electropump voltage 1X230 V- Liquid temperature 50° C- Max operating pressure 10 bar- Pressure regulation range 1÷ 6 Bar- Set point 1- Inlet 1” 1/4 M (male)- Outlet 1” 1/2 F (female)- Protection degree IP55

Protection Devices- Dry running- Overcurrent- Overtemperature of the electronics

Applications- Irrigation- Industry- Hotel installations- Buildings- Washing systems

ZB902320 VSD1 mono 8.5 22 28 18 3.7

L H P

VSD1mono is a variable frequency drive control system for electrical water pump consist of: a built in pressure sensor, a flowsensor and an inverter all in a unique box. VSD1mono can work with any kind of pump: multi stage / single stage pump, surfaceor submersible pump. VSD1mono are factory provided with cables. VSD1mono uses the built in inverter to controls the speedof the motor maintaining a constant pressure in the plants. When the flow increases, he speed of the motor increase maintainingalways a constant pressure.

• COMPACT SIZE• HIGH RELIABILITY• EXTREMELY SILENT

Working Position

DIMENSIONS AND WEIGHTS

174 L

P

1”1/4 M

1”1/2 F

H

Dimensions mm. Weightkg.ModelCode

Page 256: Electric Pumps Catalogue

VSD - PUMP SELECTION TABLEPUMP SELECTION TABLE

262

VLR2B 30/2 to VLR2B - 110

VLR 4 - 20 to VLR 4 - 60

VLR8 - 20 to VLR8 - 30

VLR2B 30/2 to VLR2B - 220

VLR4 - 20 to VLR4 - 120

VLR8 - 20 to VLR8 - 60

VLR16 - 30/2

VLR2B 30/2 to VLR2B – 260

VLR4 - 20 to VLR4 - 160

VLR8 - 20 to VLR8 - 80

VLR16 - 30/2 to VLR16 - 60

MULTINOX-VE 200/40

WHOLE RANGE

WHOLE RANGE

MCX 80/36 to MCX 80/60

MCX 120/36 to MCX 120/60

MCX 200/40

WHOLE RANGE

WHOLE RANGE

WHOLE RANGE

WHOLE RANGE

WHOLE RANGE

WHOLE RANGE

FULL RANGE

MXA 200/40

JET 600 to JET 1000

CM 90/22 to CM 100/36

CB 80/38 to CB90/44 CB 80/38 to CB120/65 CB 80/38 to CB190/76

WHOLE RANGE

SCM 4 PLUS 40/57 to SCM 4 PLUS 40/90

SCM 4 PLUS 55/50 to SCM 4 PLUS 55/80

SCM 4 PLUS 75/56 to SCM 4 PLUS 75/75

SCM 4 PLUS 115/30 to SCM 4 PLUS 115/95

SCM 4 PLUS 150/42 to SCM 4 PLUS150/84

SCM 4 PLUS 250/53 to SCM 4 PLUS 250/100

SCM 4 HF 400/30 to 400/80

SA 615/4 to SA 615/6

ELECTRIC PUMPS VSD1 Basic VSD1 VSD3

VLR

MULTINOX VE

DHR

DHI

MCX

MULTINOX

MAX

MULTINOX A

JET

CM

CB

DOMINATOR 5

SCM 4 PLUS

SCM 4 HF 4OO

SA

IDR.SCM4PLUS 75/75 withMOT. EL.4”HP1T V3X230/50

IDR.SCM4PLUS 75/75 withMOT. EL.4”HP1T V3X230/50

IDR.SCM4PLUS 115/65 withMOT. EL.4”HP1T V3X230/50

IDR.SCM4PLUS 150/42 withMOT. EL.4”HP1T V3X230/50

IDR.SCM4PLUS 115/95 withMOT. EL.4”HP1,5T V3X230/50

IDR.SCM4PLUS 150/64 withMOT. EL.4”HP1,5T V3X230/50

IDR.SCM4PLUS 150/84 withMOT. EL.4”HP2T V3X230/50

IDR.SCM4PLUS 115/65 withMOT. EL.4”HP1T V3X230/50

IDR.SCM4PLUS 150/42 withMOT. EL.4”HP1T V3X230/50

IDR.SCM4PLUS 250/53 withMOT. EL.4”HP2T V3X230/50

Page 257: Electric Pumps Catalogue

FLUSSCONTROL WITH CABLE

Page 258: Electric Pumps Catalogue
Page 259: Electric Pumps Catalogue

AQUA TROL

265

Advantages- Start up pressure adjustable from 1.5 to 3 Bar- Protection in case of excessive water temperature- Protection from an excessive number of restartings per hour.- Limited dimensions- Easy to install (version with 1.5 Mt. H07 RNF power cable)- It replaces the traditional pressure switch.

Applications

Control and protection of single-phasesurface electro pumps with supply vesselfor domestic water supply system,gardening and irrigation in general.

FunctioningAQUA TROL controls the start-up and thestop of the pumps when water isrequested (when the tab is turnedon or off)AQUA TROL protects the pump fromrunning in dry conditions: if thetemperature of the water flow exceedsthe maximum limit set, a sensor insidethe AQUA TROL prevents the electropump from starting, signalling the anomalyon the front panel.In the event that pressure falls within thesupply vessel, a timer controls theoperation of the pump, protecting it frombeing started too frequently within thesame hour.It can be installed with membrane tanksof 24, 60, 100, 200, 300 and 500 Lt.

Technical features

- Power supply 230V mono- Max. intensity 10 A- Max. absorbed power of the pump 1,5 Kw- Frequency 50-60 HZ- Protection class IP 54- Max. pressure 10 BAR- Max. temperature of the fluid 60˚C- Weight 0,75 Kg

AQUA TROL

MODEL

AQUA TROL with power cable

ELECTRONIC CONTROL AND PROTECTION PRESSURE SWITCH FOR ELECTRICSINGLE-PHASE PUMPS

Page 260: Electric Pumps Catalogue

CONTROL PANELS

Page 261: Electric Pumps Catalogue

QES PLUSSINGLE PHASE STARTER FOR THE CONTROL AND PROTECTION OF SUBMERGEDELECTRIC PUMPS, DIRECT START

Type of functioning- Manual through general switch- Automatic through external remote control (manostat, float…)

Main components- IP55 plastic box- Main switch with circuit breaker and motor- Protector with restart button- Capacitor.- Terminal board- Cable gland

Technical features- Protection level : IP55- Power supply voltage : 230V/ 1F 50 Hz- External dimensions : 115 - 185 - 65 mm- Weight : Kg 0,6

Connection plan

267

CO

NTR

OL P

AN

ELS

230 1F230 1F

230 1F

230 1F

0,370,55

0,55

0,75

0,50,75

0,75

1

46

6

7SCM 4” PLUS

SCM 4 HF4” MOTORS

230 1F 0,75 1 7

Suitable PumpsMODELCODE

V Kw Hp A

NominalPower Field µF

1620

25

30

35

Supply Voltage50Hz

230 1F 1,1 1,5 9 40

230 1F 1,5 2 12 50

Limits in use- Environmental temperature : -5 / +40 °C- Relative humidity : 50% at 40°C (without forming of condense)- Standards : EN 60335-1 - EN 60439-1

Optional accessories- Float switch or pressure switch (see accessories table)

UZQ12710UZQ12720

UZQ12730

UZQ12740

UZQ12750

UZQ12930

UZQ12940

QES PLUS 10/37 MQES PLUS 10/55 M

QES PLUS 10/75 M

QES PLUS 10/110 M

QES PLUS 10/150 M

QES PLUS 10/55 M

QES PLUS 10/75 M

Page 262: Electric Pumps Catalogue

SINGLE PHASE STARTERS FOR THE CONTROL AND PROTECTION OF SUBMERGEDOR SURFACE PUMPS, DIRECT START

QEC+S/QEM+S

Type of functioning- Manual through general switch- Automatic through external remote control (Manostat, float…)

Main components- IP 45 plastic box.- ON – OFF switch- TEST button- Motor protector with restart button- Power led- Function light- Terminal board- Cable gland- Capacitor (QEC+S)

Technical features- Protection level : IP45- Power supply voltage : 230V/ 1F 50 Hz- External dimensions : 205 - 150 – 75 mm- Weight : Kg 0,8 - 1

230 1F230 1F

230 1F

230 1F

0,370,55

0,75

1,1

0,50,75

1

1,5

35

8

9

SCM 4” PLUSSCM 4 HF

4” MOTORS

230 1F

230 1F

230 1F

230 1F

1,5

0,37

0,55

0,75

2

0,5

0,75

1

12

3

5

8

Suitable PumpsMODELCODE

UZQ12760 QEC+S 10/37

V Kw Hp A

NominalPower

Field

230 1F 1,1 1,5 9

Surface Submerged

230 1F 1,5 2 12

UZQ12770 QEC+S 10/55

UZQ12780 QEC+S 10/75

UZQ12790 QEC+S 10/110

UZQ12800 QEC+S 10/150

UZQ12810 QEM+S 10/37

UZQ12820 QEM+S 10/55

UZQ12830 QEM+S 10/75

UZQ12840 QEM+S 10/110

UZQ12850 QEM+S 10/150

µF

1620

30

40

50

VLR-VLRI-VLRXDHR-DHI-MCX

MULTINOX-MAXMULTINOX AJET-JETINOXCM-CB-EP

PRATIKADOMINATOR 4”DOMINATOR 5”

Connection plan

268

Supply Voltage50Hz

Limits in use- Environmental temperature : -5 / +40 °C- Relative humidity : 50% at 40°C (without forming of condense)- Standards : EN 60439-1

Optional accessories- UZA00100 - ECL electrodes for level control- Float switch or pressure switch (see accessories table)

QEC+S

QEM+S

Page 263: Electric Pumps Catalogue

QET+STHREE PHASE STARTER FOR THE CONTROL OF SUBMERGED OR SURFACEELECTRIC PUMPS, DIRECT START

Type of functioning- Manual through general switch- Automatic through external remote control (manostat or float…)

Main components- IP 45 plastic box.- ON – OFF switch- TEST button- Contactor thermal relay- Power led- Function led- Thermal block light with restart button- Terminal board- Cable gland

Technical features- Protection level : IP45- Power supply voltage : 400V/ 3F+N 50 Hz- External dimensions : 205 - 150 – 75 mm- Weight : Kg 1

400 3F+N400 3F+N

400 3F+N

400 3F+N

0,550,75

1,5

3

0,751

2

4

1,82,6

3,7

5,5

400 3F+N 4 5,5 8

Suitable PumpsMODELCODE

UZQ12860 QET+S 10/55

Supply Voltage50Hz

Kw Hp min

NominalPower

Field

UZQ12870 QET+S 10/75

UZQ12880 QET+S 10/150

UZQ12890 QET+S 10/300

UZQ12900 QET+S 10/400

Connection plan

400 3F+N 5,5 7,5 10UZQ12910 QET+S 10/550

2,63,7

5,5

8

11,5

max

14

VLR-VLRI-VLRXDHR-DHI-MCX

MULTINOX-MAXMULTINOX A

MULTINOX VEJET-CM-CB-EP

NRM

DOMINATOR 5"SCM4"PLUS

SCM4 HF4" MOTORS

269

CO

NTR

OL P

AN

ELS

VA

Limits in use- Environmental temp. : -5 / +40 °C- Relative humidity : 50% at 40°C (without forming of condense)- Standards : EN 60439-1

Optional accessories- UZA00100 - ECL electrodes for level control- Float switch or pressure switch (see accessories table)

Surface Submerged

Page 264: Electric Pumps Catalogue

THREE PHASE STARTER FOR THE CONTROL OF SUBMERGED OR SURFACEELECTRIC PUMPS, DIRECT START

AD

Type of functioning- Manual through Man. or Aut. Selector- Automatic through external remote control (manostat, float, …) and/or level control (filling, emptying, dry function protection)

Main components- IP 54 painted metallic case.- Main switch, door block- Fuse block with fuses on the main circuit- Fuse block with fuses on the auxiliary circuit- Ammeter with amperometric transformer- Voltmeter with voltmetric selector- Level block light- Function light- Power led- Thermal block light- Terminal board- Contactor 24 V- Overload protection and phase absence thermal relay- Level control module- Transformer for auxiliary circuit- Cable gland- MAN -or -AUT Selector

Technical features- Protection level : IP54- Power supply voltage : 400V/ 3F 50 Hz- External dimensions : 320 - 400 - 180 mm- Weight : Kg 14-50

Suitable PumpsMODELCODE

Kw HpA

min

NominalPower

Field

Surface Submerged

Connection plan

400 3F400 3F400 3F400 3F

5,5

9,2

1115

7,5121520

VLR - VLRIVLRX - NRM

9142028

15233138

SCM4"PLUSSCM4 HF

4"/6" MOTORSSA

UZQ02700UZQ02900UZQ03000UZQ03100

Q.E. AD10/550Q.E. AD10/920Q.E. AD10/1100Q.E. AD10/1500

max

270

Supply Voltage50Hz

V

Limits in use- Environmental temp. : -5 / +40 °C- Relative humidity : 50% at 40°C (without forming of condense)- Standards : EN 60730 - EN 60439

Optional accessories- UZA00100 ECL electrodes for level control- CE040010 Panel wall mount fixing fins- Float switch or pressure switch (see accessories table)

Page 265: Electric Pumps Catalogue

271

CO

NTR

OL P

AN

ELS

AY/ARTHREE PHASE STARTERS FOR THE CONTROL OF SUBMERGED OR SURFACEELECTRIC PUMPS

Type of functioning- Manual through Man. or Aut. Selector,- Automatic through external remote control (manostat, float, …) and/or level control (filling, emptying, dry function protection)

Main components- IP 54 painted metallic case- Main switch, door block- Fuse block with fuses on the auxiliary circuit- Ammeter with amperometric transformer- Voltmeter with voltmetric selector- Level block light- Function light- Power led- Thermal block light- Terminal board- Overload protection and phase absence thermal relay- Level control module- Transformer for auxiliary circuit- Cable gland- MAN -or -AUT Selector

Technical features- Protection level : IP54- Power supply voltage : 400V/ 3F 50 Hz Connection plan

Suitable PumpsMODELCODE

Kw HpA

min

NominalPower

Field

maxUZQ03800UZQ03900UZQ04000UZQ04200

Q.E. AY10/400Q.E. AY10/550Q.E. AY10/920Q.E. AY10/1500

UZQ04300UZQ04400UZQ04500UZQ04600

Q.E. AY10/1850Q.E. AY10/2200Q.E. AY10/3000Q.E. AY10/3700

400 3F400 3F400 3F400 3F

45,5

9,2-1115

5,57,5

12-1520

8111625

12162535

VLR - VLRIVLRX - NRM

400 3F400 3F400 3F400 3F

18,522

30-3337

2530

40-4550

34405060

44526282

400 3F400 3F400 3F400 3F

5,57,59,211

7,5101215

9141417

15162025

400 3F400 3F400 3F400 3F

12,5-1518,522

30-33

17,5-202530

40-45

25344050

35445262

UZQ04700UZQ04800UZQ04900UZQ05000

Q.E. AR10/550Q.E. AR10/750Q.E. AR10/920Q.E. AR10/1100

UZQ05100UZQ05200UZQ05300UZQ05400UZQ05500

Q.E. AR10/1500Q.E. AR10/1850Q.E. AR10/2200Q.E. AR10/3300Q.E. AR10/4000 400 3F 37-40 50-55 60 82

Surface Submerged

6” MOTORSSA

Supply Voltage50Hz

V

Limits in use- Environmental temp. : -5 / +40 °C- Relative humidity : 50% at 40°C (without forming of condense)- Standards : EN 60730 - EN 60439

Optional accessories- UZA00100 - ECL electrodes for level control- CE040020 - Panel wall mount fixing fins- Float switch or pressure switch (see accessories table)

AY SERIES- Fuse block with fuses on the main circuit- Timer for S/T exchange- Line – star-triangle contactors- Star/triangle start level control- External dimensions : 400 - 600 - 220 mm- Weight : Kg 25-95

AR SERIES- Start reactance- Timing for excluding reactance- Start and function contactors- Reactance protection thermal relay- Indirect reactance start level control- External dimensions : 550 x 750 x 250 mm- Weight : Kg 25-103

AR

AY

Page 266: Electric Pumps Catalogue

SINGLE PHASE STARTERS FOR THE CONTROL OF ONE OR TWO DRAINING ANDSEWAGE ELECTRIC PUMPS

ADRM

Type of functioning- Manual through general switch.- Automatic through float switch.

Main components- IP 54 metallic case- General switch- Fuse block with fuses for the electric pump- Contactor with thermal relay- Transformer for auxiliary circuit- Fuse block with fuses on the auxiliary circuit- Terminal board with level control devices- Cable gland- Function light- Power led- Thermal block light- Level alarm

ADRM 10

- Electronic signalling, control and command card- For the control of one electric pump- Weight : Kg 5,5

Connection plan

Technical features- Protection level : IP54- Power supply voltage : 220V/240V 1F 50 Hz- External dimensions : 220 x 270 x 185 mm

ADRM 20

- Electronic signalling, control and command card equipped with cyclic startings converter- For the control of two electric pumps- Weight : Kg 7,5

ADRM10

ADRM20

272

Suitable PumpsMODELCODE

Supply Voltage50Hz

V Kw HpA

min

Nominalpower

Field

230 1F230 1F230 1F

0,550,751,1

0,751

1,5

2,54

6,3

46,310

DRENOX OMNIAPRIOX MINIVORT P

MINIVORT PP

UZQ06500UZQ06700UZQ06800UZQ06900

Q.E. ADRM10/55Q.E. ADRM10/75Q.E. ADRM10/110Q.E. ADRM10/150 230 1F 1,5 2 10 16

230 1F230 1F230 1F

2x0,552x0,752x1,1

2x0,752x1

2x1,5

2,54

6,3

46,310

UZQ08600UZQ08800UZQ08900UZQ09000

Q.E. ADRM20/55Q.E. ADRM20/75Q.E. ADRM20/110Q.E. ADRM20/150 230 1F 2x1,5 2x2 10 16

max

Limits in use- Environmental temperature : -5 / +40 °C- Relative humidity : 50% at 40°C (without forming of condense)- Standards : EN 60730 - EN 60439

Optional accessories- CE040030 - Panel wall mount fixing fins- UZA00200 - Optical, acoustic alarm- Float switches (see accessories table)

ADRM10

ADRM20

Page 267: Electric Pumps Catalogue

ADRDTHREE PHASE STARTERS FOR THE CONTROL OF ONE OR TWO DRAINING ANDSEWAGE ELECTRIC PUMPS

Type of functioning- Manual through general switch- Automatic through float switch

Main components- IP 54 metallic case- General switch- Fuse block with fuses for the electric pump- Contactor with thermal relay- Transformer for auxiliary circuit- Fuse block with fuses on the auxiliary circuit- Terminal board with level control devices- Cable gland- Function light- Power led- Thermal block light- Level alarm

Technical features- Protection level : IP54- Power supply voltage : 400V 3F 50 Hz- External dimensions : 220 x 270 x 185 mm- Weight : Kg 5,5

Connection plan

273

CO

NTR

OL P

AN

ELS

ADRD10

ADRD20

Suitable PumpsMODELCODESupply Voltage

50Hz

V Kw HpA

min

Nominalpower

Field

max400 3F400 3F400 3F400 3F400 3F400 3F400 3F400 3F

400 3F400 3F400 3F400 3F400 3F

0,551,11,5

0,751,52

11,62,5

1,62,54

DRENOX PRIOXMINIVORT P

MINIVORT PPFGT - FGV

UZQ07000UZQ07100UZQ07300UZQ07400

Q.E. ADRD10/55Q.E. ADRD10/110Q.E. ADRD10/150Q.E. ADRD10/300 3 4 4 6,3

57,59

2x0,55

6,71012

2x0,75

6,310131

1016191,6

UZQ07500UZQ07700UZQ07800UZQ09100

Q.E. ADRD10/500Q.E. ADRD10/750Q.E. ADRD10/900Q.E. ADRD20/55

2x1,12x1,52x3

2x1,52x22x4

1,62,54

2,54

6,3

UZQ09200UZQ09400UZQ09500UZQ09600

Q.E. ADRD20/110Q.E. ADRD20/150Q.E. ADRD20/300Q.E. ADRD20/500 2x5 2x6,7 6,3 10

2x7,52x9

2x102x12

1013

1619

UZQ09800UZQ09900

Q.E. ADRD20/750Q.E. ADRD20/900

400 3F

Limits in use- Environmental Temperature : -5 / +40 °C- Relative humidity : 50% at 40°C (without forming of condense)- Standards: EN 60730 - EN 60439

Optional accessories- CE040030 - Wall mount fixing fins- UZA00200 - Optical, acoustic alarm- Float switches (see accessories table)

ADRD10- Electronic signalling, control and command card- For the control of one electric pump

ADRD20- Electronic signalling, control and command card equipped with cyclic startings converter- For the control of two electric pumps

ADRD10

ADRD20

Page 268: Electric Pumps Catalogue

THREE PHASE STARTERS FOR THE CONTROL OF ONE OR TWO DRAINING ANDSEWAGE ELECTRIC PUMPS, STAR-TRIANGLE START

ADRY

Type of functioning- Manual through general switch.- Automatic through float switch.

Main components- IP 54 metallic case- General switch- Fuse block with fuses for the electric pump- Contactor with thermal relay- Transformer for auxiliary circuit- Fuse block with fuses on the auxiliary circuit- Electronic signalling, control and command- card equipped with:- Function light- Power led- Thermal block light- Electronic keyboard with leds VOLT/AMPERE- Terminal board with level control devices- Cable gland

ADRY10- Electronic signalling, control and command card- For the control of one electric pump- Weight : Kg 12-60

Connection planTechnical features- Protection level : IP54- Power supply voltage : 400V 3F 50 Hz- External dimensions : 500 x 750 x 250 mm

ADRY20- Electronic signalling, control and command card equipped with cyclic startings converter- For the control of two electric pumps- Weight : Kg 15-85

274

Limits in use- Environmental temperature: -5 / +40 °C- Relative humidity : 50% at 40°C (without forming of condense)- Standards : EN 60730 - EN 60439

Optional accessories- CE040020 - Wall mount fixing fins- UZA00200 - Optical, acoustic alarm- Float switches (see accessories table)

ADRY10

ADRY20

Suitable PumpsMODELCODE

Supply Voltage50Hz

V Kw HpA

min

Nominalpower

Field

400 3F400 3F400 3F

91115

121520

12,917,222,4

1924,132,8

FGC-FGV

UZQ07900UZQ08100UZQ08200UZQ08300UZQ08400

Q.E. ADRY10/900Q.E. ADRY10/1100Q.E. ADRY10/1500Q.E. ADRY10/2200Q.E. ADRY10/2500

400 3F 22 30 29,3 44,8400 3F 25 33,5 37,9 55,2400 3F400 3F400 3F

2x92x112x15

2x122x152x20

12,917,222,4

1924,132,8

UZQ10000UZQ10200UZQ10300UZQ10400UZQ10500

Q.E. ADRY20/900Q.E. ADRY20/1100Q.E. ADRY20/1500Q.E. ADRY20/2200Q.E. ADRY20/2500

400 3F 2x22 2x30 29,3 44,8400 3F 2x25 2x33,5 37,9 55,2

max

Page 269: Electric Pumps Catalogue

275

ACCESSORIES FOR CONTROL PANELS

Accessories

CE040010 AD10

Fixing fin kit for “wall” assembly of the panel

CE040020

CE040030

Fixing finsFixing fins

Fixing finsAY10 - AR10 - ADRY10 - ADRY20

ADRM10 - ADRM20 - ADRD10 - ADRD20

UZA00200 ADRM10 - ADRM20 - ADRD10 - ADRD20ADRY10 - ADRY20

Alarm kit for draining panels, composed by a 12V cc siren and red signalling led installed in anIP54 plastic box with cable gland.

A0A12C alarm 12 V

ZA008120 ADRM10 – ADRM20 – ADRD10 – ADRD20DRY10 – ADRY20

“MERCURY” MC type 15 m float switch, watertight up to a depth of 100 m, insensible tocondense, fit for waste water.

Mercury float switch MC.15m

UZA00100 QEC+S – QEM+S – QET+S – AD10 –AY10AR10

Level electrodes particularly fit for conductible liquids up to a maximum temperature of40°C. For the connection between electrode and panel you can use an isolated cable withmaximum 4 mm2 connection and max. length of 100m.

ECL electrodes for level control ofconductible liquids

ZA000590 QES PLUS – QEC+S – QEM+S – QET+SAD10 – AY10 – AR10

Key type level regulator for emptying and refilling applications equipped with 3 m or 10 mcable, fit for uses with clean water and residues of agglomerate.

ZA000330

ZA000650

MICROSTART 3-3Emptying/f i l l ingMICROSTART 10-2 Emptying

MICROSTART 5-2 EmptyingAll the panels that use an external remote control

ZA000750

ZA008510 MICROSTART 10-3Empty i ng / f i l l i ng

QES PLUS – QEC+S – QEM+S – QET+SAD10 – AY10 – AR10

MICROSTART 10-2 (PVC) EmptyingAll the panels that use an external remote control

All the panels that use an external remote control

CODE TYPE CONTROL PANELS

ZA003110 QES PLUS – QEC+S – QEM+S – QET+SAD10 – AY10 – AR10

ZA006400

ZA000630

PM 5 ITL (6 Atm. Max)

PM 12 ITL (12 Atm. Max)

PM 6 TEL (6 Atm. Max)

ZA000640 PM 12 TEL (12 Atm. Max)

QES PLUS – QEC+S – QEM+S – QET+SAD10 – AY10 – AR10

QES PLUS – QEC+S – QEM+S – QET+SAD10 – AY10 – AR10

QES PLUS – QEC+S – QEM+S – QET+SAD10 – AY10 – AR10

PANEL SUPPORT CHUCK KIT

OPTICAL AND ACOUSTIC ALARM

SUBMERGED LEVEL REGULATORS

COUNTERWEIGHT LEVEL REGULATORS

ELECTRODES FOR LEVEL CONTROL OF CONDUCTIBLE LIQUIDS

PRESSURE SWITCH

CODE TYPE CONTROL PANELS

CODE TYPE CONTROL PANELS

CODE TYPE CONTROL PANELS

CODE TYPE CONTROL PANELS

CODE TYPE CONTROL PANELS

AC

CE

SSO

RIE

S

Page 270: Electric Pumps Catalogue

Accessories

276

ZB401770

ZB41780

B 1

B 2

CODE MODEL DESCRIPTION

ZA003110

ZA006400

ZA009550

ZA000630

ZA000640

PM 5 ITAL

PM 12 ITAL

PTI LP3 ITAL

PT 6 TEL

PT 12 TEL

PRESSURE SWITCH - 6 ATM - ITALTECNICA

PRESSURE SWITCH - 12 ATM - ITALTECNICA

PRESSURE SWITCH - 6 ATM - TELEMECANIQUE

PRESSURE SWITCH - 12 ATM - TELEMECANIQUE

PRESSURE SWITCH - LP3 INVERSED - 1/4” F ITALTECNICA

ZA004520

ZA007110

ZA004080

KA4

KA7

NIPPLEX 1” M-M

SUCTION KIT 4 m

SUCTION KIT 7 m

1” MALE THREADED NIPPLE FOR SUCTION KIT

ZA000270

ZA003060

ZA003160

ZA003070

ZA007430

ZA007440

ZA007450

ZA007460

TF 500

TF 600

TF 700

TF 800

GA 1” 1/4

GA 2”

GA 2” 1/2

GA 3”

1” x mm 500 M-F FLEXIBLE PIPE

1” x mm 600 M-F FLEXIBLE PIPE

1” x mm 700 M-F FLEXIBLE PIPE

1” x mm 800 M-F FLEXIBLE PIPE

1” 1/4 x mm 400 M-F FLEXIBLE PIPE

2” x mm 500 M-F FLEXIBLE PIPE

2” 1/2 x mm 500 M-F FLEXIBLE PIPE

3” x mm 500 M-F FLEXIBLE PIPE

ZA002030

ZB902150

ZA000680

ZA000780

MAR 6

MAP 6

MAR 10

MAP 10

6 BAR RADIAL MOUNTING PRESSURE GAUGE

6 BAR REAR MOUNTING PRESSURE GAUGE

10 BAR RADIAL MOUNTING PRESSURE GAUGE

10 BAR REAR MOUNTING PRESSURE GAUGE

ZA000240

ZA000260

R 3 V

R 5 V

3 WAY BRASS FITTING 1”

5 WAY BRASS FITTING 1”

PRESSED STEEL BASE KIT WITH SCREWS FOR

MCX 80-120 E JETINOX 45-60-70

MAX 80-120

PRESSED STEEL BASE KIT WITH SCREWS FOR

MCX 200 E JETINOX 90

D6024KKK

ZA006380

ZA003050

ZA010200

ZA009190

ZA009200

ZA009210

ZA009220

ZA009230

MBF

MBB

MGS 2

MGS 24

MB 60

MB 100

MB 200

MB 300

MB 500

BROMOBUTYL DIAPHRAGM FOR FLEXINOX 20 LITER TANKS

BROMOBUTYL DIAPHRAGM FOR INOX TANKS

FOOD-QUALITY RUBBER DIAPHRAGM FOR 2 LITER TANK

FOOD-QUALITY RUBBER DIAPHRAGM FOR 24 LITER TANK

FOOD-QUALITY RUBBER DIAPHRAGM FOR 60 LITER TANK

FOOD-QUALITY RUBBER DIAPHRAGM FOR 100 LITER TANK

FOOD-QUALITY RUBBER DIAPHRAGM FOR 200 LITER TANK

FOOD-QUALITY RUBBER DIAPHRAGM FOR 300 LITER TANK

FOOD-QUALITY RUBBER DIAPHRAGM FOR 500 LITER TANK

Page 271: Electric Pumps Catalogue

Accessories

277

ZA000420

ZA000430

ZA000440

ZA000450

ZA000460

ZA000470

CABLE 4 x 1

CABLE 4 x 1,5

CABLE 4 x 2,5

CABLE 4 x 4

CABLE 4 x 6

CABLE 4 x 10

CODE MODEL DESCRIPTION

ZA000020

ZA003000

ZA003190

ZA003200

ZA003210

ZA002020

ZA003220

ZA003230

ZA003240

ZA008430

ZA009720

VF 1”

VFF 1”

VFF 1” 1/4

VFF 1” 1/2

VFF 2”

VAR 1”

VAR 1” 1/4

VAR 1” 1/2

VAR 2”

RVFF 2

PDA 2”

ZA000900

ZA000910

ZA000920

RCF 30

RCF 40

RCF 50

ZA003370

ZA003390

ZA003380

ZA009410

ZA009430

ZA009450

JOINT KIT 2,5

JOINT KIT 6

JOINT KIT 10

JOINT 2,5

JOINT 6

JOINT 10

1” PLASTIC FOOT VALVE

1” BRASS FOOT VALVE WITH STAINLESS STEEL FILTER

1” 1/4 BRASS FOOT VALVE WITH STAINLESS STEEL FILTER

1” 1/2 BRASS FOOT VALVE WITH STAINLESS STEEL FILTER

2” BRASS FOOT VALVE WITH STAINLESS STEEL FILTER

1” BRASS NON RETURN VALVE

1” 1/4 BRASS NON RETURN VALVE

1” 1/2 BRASS NON RETURN VALVE

2” BRASS NON RETURN VALVE

2” BALL VALVE WITH FULL BORE

COUPLING FOOT 2”

3 M FLOAT 3 WIRES FOR EMPTYING/FILLING

10 m FLOAT 2 WIRES FOR EMPTYING/FILLING H07-RNF

5 m FLOAT 2 WIRES FOR EMPTYING H05-RNF

10 m PVC FLOAT 2 WIRES FOR EMPTYING

5 m FLOAT 2 WIRES WITH PLUG AND SOCKET H05 - RNF

10 m PVC FLOAT 2 WIRES WITH PLUG AND SOCKET

15 m FLOAT SWITCH MERCURY MC

10 m FLOAT 3 WIRES FOR EMPTYING/FILLING

COUNTERWEIGHT FOR FLOAT

NEOPRENE HO7 RNF 4 WIRE CABLE 1 MM2 WIRES

NEOPRENE HO7 RNF 4 WIRE CABLE 1,5 MM2 WIRES

NEOPRENE HO7 RNF 4 WIRE CABLE 2,5 MM2 WIRES

NEOPRENE HO7 RNF 4 WIRE CABLE 4 MM2 WIRES

NEOPRENE HO7 RNF 4 WIRE CABLE 6 MM2 WIRES

NEOPRENE HO7 RNF 4 WIRE CABLE 10 MM2 WIRES

HEAT-SHRINK SPLICING KIT FOR CABLES UP TO 4 X 2,5 MM2

HEAT-SHRINK SPLICING KIT FOR CABLES UP TO 4 X 6 MM2

RESIN FILLED SPLICING KIT FOR CABLES UP TO 4 X 10 MM2

HEAT-SHRINK SPLICING JOINT FOR CABLES UP TO 4 X 2,5

HEAT-SHRINK SPLICING JOINT FOR CABLES UP TO 4 X 6

RESIN FILLED SPLICING JOINT FOR CABLES UP TO 4 X 10

1” 1/4 FEMALE ELBOW HOSE HOLDER ø 30 mm

1” 1/2 FEMALE ELBOW HOSE HOLDER ø 40 mm

2” FEMALE ELBOW HOSE HOLDER ø 50 mm

ZA009330

ZA009320

ZA009310

VRP 1” 1/4

VRP 1” 1/2

VRP 2”

MICROSTART 3-3

MICROSTART 10-2

MICROSTART 5-2

MICROSTART 10 -2

MICROSTART S 5-2

MICROSTART S10-2

MERCURY 15 M

MICROSTART 10-3

CP

ZA000590

ZA000330

ZA000650

ZA000750

ZA000350

ZA010070

ZA008120

ZA008510

ZA000820

STAINLESS STEEL BALL CHECK VALVE 1” 1/4 F

STAINLESS STEEL BALL CHECK VALVE 1” 1/2 F

STAINLESS STEEL BALL CHECK VALVE 2” F

AC

CE

SSO

RIE

S

ZA009720 PDA 2” 2” COUPLING FOOT

Page 272: Electric Pumps Catalogue

Accessories

278

FILTERS AND FILTERING CARTRIDGES

CARTRIDGES BOWL

ZB401390

ZB900010

ZB900060

ZB900030

ZB900070

CODE DESCRIPTIONMin.

quantity

ANTI-SCALE FILTER COMPLETE ( FOR WASHING MACHINE )

5” FILTER 1” CONNECTION

CF 7” 1” CONNECTION

CF 10” 1” CONNECTION

CF 10” 1” 1/4 CONNECTION

1

1

1

1

1

ZB401350

ZB401370

ZB401410

ZB401550

ZB401360

ZB401570

ZB401380

ZB401580

ZB401420

ZB401620

20

60

20

60

20

20

60

60

60

-

20

20

20

20

20

20

20

20

20

1

CODE DESCRIPTION Min.quantity

Nom.filtr. µm

FILTERING CARTRIDGES

5” CARTRIDGE FA (WOUND WIRE)

5” CARTRIDGE NY (NYLON MESH)

7” CARTRIDGE FA (WOUND WIRE) FOR FILTER 1” CONNECTION

7” CARTRIDGE NY (NYLON MESH) FOR FILTER 1” CONNECTION

10” CARTRIDGE FA (WOUND WIRE) FOR FILTER 1” CONNECTION

10” CARTRIDGE FA (WOUND WIRE) FOR FILTER 1 1/4” CONNECTION

10” CARTRIDGE NY (NYLON MESH) FOR FILTER 1” CONNECTION

10” CARTRIDGE NY (NYLON MESH) FOR FILTER 1 1/4” CONNECTION

10” CARTRIDGE CA (NYLON MESH + ACTIVE CARBON)

10” CARTRIDGE PL (CRYSTALLINE POLYPHOSPHATE)

Page 273: Electric Pumps Catalogue

Technical data subject to change without notice.PENTAIR WATER ITALY S.r.l. reserves the right to carry out modifications to its products at any time without having to provide prior notice.

Page 274: Electric Pumps Catalogue

ww

w.f

ranc

ofer

rucc

i.com

GB

- 3°

ED

. 052

008

- CO

D. N

V26

0P36

0

RUSSIAPentair Pumps4 Luchevoy ProsekExhibition Centre “Sokolniki”Pav. 5, Off. 23 - MoscowTel.+7-495-913 90 22, 956 55 61Fax +7-495-980 12 97www.nocchi.ru

REPUBLIC OF SOUTH AFRICAPentair WaterP.O. Box 11325, Selcourt 1567,15 Miller Road,Nuffield, Springs - GautengTel. +27.11.818.5818Fax +27.11.818.3710

Pentair WaterVia Brughiera 1 - 20010PREGNANA MILANESE (MI)Tel. +39.02.93.27.111Fax. +39.02.93.27.1154www.pentairwater.com

ITALYPentair Water Italy S.r.l.Via Masaccio, 1356010 Lugnano (Pisa)Tel. +39.050.71.61.11Fax. +39.050.70.31.37www.nocchi.it

Pentair Water

GERMANYPentair WaterWiesenstraße 6Industriegebiet NordD-64347 GriesheimTel. +49.61.55.84.170Fax +49.61.55.84.17.99

140, avenue Roland Garros78532 BUC CEDEXTel. +33.(0)1.39.24.15.00Fax. +33.(0)1.39.56.03.90www.pentairwater.com

FRANCEPentair PumpsBP 92 Vedéne - 84965LE PONTET Cedex - AVIGNONTel. 04.90.480.880Fax 04.90.480.888www.nocchi.it

BELGIUMPentair WaterIndustriepark Wolfstee,Toekomstlaan 30B-2200 HERENTALSTel. +32.14.25.99.11Fax. +32.14.25.99.75www.pentairwater.com

UNITED KINGDOMPentair Water FiltrationDaimler Drive, Cowpen LaneIndustrial EstateBillingham - Cleveland, TS23 4DJTel. +44 (0)1 642 370 616Fax +44 (0)1.642.564.708

UNITED ARAB EMIRATESPentair Water Middle EastApt. # 404, Al Buhaira Building-Corniche StreetAl Buhaira - Al MajazP.O. Box 32789Sharjah, U.A.E.Tel. +971.65.72.05.52Fax. +971.65.72.05.53www.pentairwater.com

SPAINPentair WaterMI I Fontanals 28, 08205Sabadell - BarcelonaTel +34 937 10 28 39Fax +34 937 10 47 67