ELCOSMOTOSHIBA COMPACT MACHINE ROOM ELEVATORS

Safety Cautions • Observance of relevant laws / regulations are required.

• Read the entire “Instruction Manual” carefully before use, for important information about safety, handling and operation.

• The data given in this catalog are subject to change without notice.

Printed in Japan

5-27, Kitashinagawa 6-chome, Shinagawa-ku,Tokyo 141-0001 JapanPHONE: +81-3-5423-3389 FAX: +81-3-5423-2746

ETOSHIB

Installation plan and power facility plan for Taiwan

TB408_[001-012]_TC.indd 1 09.9.17 10:29:42 AM

Page 2: ELCOSMO E - toshiba-elevator.co.jp · elcosmo toshiba compact machine room elevators ... p11-co96 w 1.6 800 1945×1770 4300 1400 1945×1770 7.3 32 100 w 900 2050×1770 2050×1770

Hoistway layout

1 2

Note:• Hoistway dimensions are the minimum dimension after the building work.• Hoistway dimensions are the minimum requirement.• The hoistway structure wall must be 150mm thick or more.• Piping, wiring and cables not related to elevator are prohibited inside the hoistway.• In case that more than one (simplex) elevator is required, please contact us.• If the size of the hoistway is greater than above sizes, OH will be larger, please contact us.• Example: P13W W: Wide car D: Deep car

P9-CO60W

9 600

1

1100×1400

800 1820×17704050 1300

1820×1770

2000

3.6 24 60W 900 2000×1770 2000×1770

P9-CO96W

1.6800 1820×1770

4300 14001820×1770

5.8 32 100W 900 2000×1770 2000×1770

P9-CO105W

1.75800 1820×1770

4300 14501820×1770

6.3 32 100W 900 2000×1770 2000×1770

P9-CO120W

2800 1820×1770

4350 16501820×1770

7.2 40 125W 900 2000×1770 2000×1770

P9-CO150W

2.5800 1820×1770

4350 21001820×1770

9.0 40 125W 900 2000×1770 2000×1770

P11-CO60W

11 750

1

1350×1400

800 1945×17704050 1300

1945×1770

2000

4.6 24 60W 900 2050×1770 2050×1770

P11-CO96W

1.6800 1945×1770

4300 14001945×1770

7.3 32 100W 900 2050×1770 2050×1770

P11-CO105W

1.75800 1945×1770

4300 14501945×1770

8.0 32 100W 900 2050×1770 2050×1770

P11-CO120W

2800 1945×1770

4350 16501945×1770

9.2 40 125W 900 2050×1770 2050×1770

P11-CO150W

2.5800 1945×1770

4350 21001945×1770

11.4 40 125W 900 2050×1770 2050×1770

P11-CO60D

11 750

1

1100×1700

800 1820×20704050 1300

1820×2070

2000

4.6 24 60D 900 2000×2070 2000×2070

P11-CO96D

1.6800 1820×2070

4300 14001820×2070

7.3 32 100D 900 2000×2070 2000×2070

P11-CO105D

1.75800 1820×2070

4300 14501820×2070

8.0 32 100D 900 2000×2070 2000×2070

P11-CO120D

2800 1820×2070

4350 16501820×2070

9.2 40 125D 900 2000×2070 2000×2070

P11-CO150D

2.5800 1820×2070

4350 21001820×2070

11.4 40 125D 900 2000×2070 2000×2070

P14-CO60W

14 950

1

1600×1400

900 2175×17704050 1300

2175×1770

2000

5.7 24 60W 1000 2275×1770 2275×1770

P14-C096W

1.6900 2175×1770

4300 14002175×1770

9.2 32 100W 1000 2275×1770 2275×1770

P14-CO105W

1.75900 2175×1770

4300 14502175×1770

10.0 32 100W 1000 2275×1770 2275×1770

P14-C0120W

2900 2175×1770

4350 16502175×1770

11.4 40 125W 1000 2275×1770 2275×1770

P14-CO150W

2.5900 2175×1770

4350 21002175×1770

14.3 40 125W 1000 2275×1770 2275×1770

P15-CO60D

15 1000

1

1100×2100

800 1820×24704050 1300

1820×2470

2000

5.7 24 60D 900 2000×2470 2000×2470

P15-CO96D

1.6800 1820×2470

4300 14001820×2470

9.2 32 100D 900 2000×2470 2000×2470

P15-CO105D

1.75800 1820×2470

4300 14501820×2470

10.0 32 100D 900 2000×2470 2000×2470

P15-CO120D

2800 1820×2470

4350 16501820×2470

11.4 40 125D 900 2000×2470 2000×2470

P15-CO150D

2.5800 1820×2470

4350 21001820×2470

14.3 40 125D 900 2000×2470 2000×2470

Counterweight at side

Hook (By general contractor)

Mac

hine

room

hei

ght M

.H

Dust-proofed(By general contractor)

Doo

r he

ight

Ove

rhea

d O

H

Top floor

Hoistway lighting(By general contractor)

Pit waterproof(By general contractor)

Ladder(By general contractor)

Pit inspection receptacle(By general contractor)

Bottom floor

Trav

el

Tota

l hei

ght

Pit

dep

th P

Hoistway section

Machine room plan

Machine room width M.A

Mac

hine

room

dep

th M

.B

Machine room door(With key)

(By general contractor)600Wx1800H

Vent

ilatio

n fa

n(B

y g

ener

al c

ontr

acto

r) Win

dow

(By

gen

eral

con

trac

tor)

Pow

er S

witc

h(B

y g

ener

al c

ontr

acto

r)

Lighting switchinspection receptacle

(By general contractor)

Door opening width W

Hoistway width X

Car inside width A

Hoistway plan

Hoi

stw

ay d

epth

Y

Car

insi

de

dep

th B

Hoistwaycenterline Car centerline

Control panel

Specifications

capacity(kw)

service stops (s)

Nos.ofPerson

Capacity(kg)

Speed(m/s)

Type

Internal (A x B)

Cage size(mm)

X x Y OH P

W(mm)

Door width Hoistway size (mm)

M.HM.A x M.B

Machine room dimensoins (mm) Motor Max. Max.

travel(m)

TB408_[001-012]_TC.indd 2 09.9.17 10:29:47 AM

Page 3: ELCOSMO E - toshiba-elevator.co.jp · elcosmo toshiba compact machine room elevators ... p11-co96 w 1.6 800 1945×1770 4300 1400 1945×1770 7.3 32 100 w 900 2050×1770 2050×1770

Hoistway layout

1 2

Note:• Hoistway dimensions are the minimum dimension after the building work.• Hoistway dimensions are the minimum requirement.• The hoistway structure wall must be 150mm thick or more.• Piping, wiring and cables not related to elevator are prohibited inside the hoistway.• In case that more than one (simplex) elevator is required, please contact us.• If the size of the hoistway is greater than above sizes, OH will be larger, please contact us.• Example: P13W W: Wide car D: Deep car

P9-CO60W

9 600

1

1100×1400

800 1820×17704050 1300

1820×1770

2000

3.6 24 60W 900 2000×1770 2000×1770

P9-CO96W

1.6800 1820×1770

4300 14001820×1770

5.8 32 100W 900 2000×1770 2000×1770

P9-CO105W

1.75800 1820×1770

4300 14501820×1770

6.3 32 100W 900 2000×1770 2000×1770

P9-CO120W

2800 1820×1770

4350 16501820×1770

7.2 40 125W 900 2000×1770 2000×1770

P9-CO150W

2.5800 1820×1770

4350 21001820×1770

9.0 40 125W 900 2000×1770 2000×1770

P11-CO60W

11 750

1

1350×1400

800 1945×17704050 1300

1945×1770

2000

4.6 24 60W 900 2050×1770 2050×1770

P11-CO96W

1.6800 1945×1770

4300 14001945×1770

7.3 32 100W 900 2050×1770 2050×1770

P11-CO105W

1.75800 1945×1770

4300 14501945×1770

8.0 32 100W 900 2050×1770 2050×1770

P11-CO120W

2800 1945×1770

4350 16501945×1770

9.2 40 125W 900 2050×1770 2050×1770

P11-CO150W

2.5800 1945×1770

4350 21001945×1770

11.4 40 125W 900 2050×1770 2050×1770

P11-CO60D

11 750

1

1100×1700

800 1820×20704050 1300

1820×2070

2000

4.6 24 60D 900 2000×2070 2000×2070

P11-CO96D

1.6800 1820×2070

4300 14001820×2070

7.3 32 100D 900 2000×2070 2000×2070

P11-CO105D

1.75800 1820×2070

4300 14501820×2070

8.0 32 100D 900 2000×2070 2000×2070

P11-CO120D

2800 1820×2070

4350 16501820×2070

9.2 40 125D 900 2000×2070 2000×2070

P11-CO150D

2.5800 1820×2070

4350 21001820×2070

11.4 40 125D 900 2000×2070 2000×2070

P14-CO60W

14 950

1

1600×1400

900 2175×17704050 1300

2175×1770

2000

5.7 24 60W 1000 2275×1770 2275×1770

P14-C096W

1.6900 2175×1770

4300 14002175×1770

9.2 32 100W 1000 2275×1770 2275×1770

P14-CO105W

1.75900 2175×1770

4300 14502175×1770

10.0 32 100W 1000 2275×1770 2275×1770

P14-C0120W

2900 2175×1770

4350 16502175×1770

11.4 40 125W 1000 2275×1770 2275×1770

P14-CO150W

2.5900 2175×1770

4350 21002175×1770

14.3 40 125W 1000 2275×1770 2275×1770

P15-CO60D

15 1000

1

1100×2100

800 1820×24704050 1300

1820×2470

2000

5.7 24 60D 900 2000×2470 2000×2470

P15-CO96D

1.6800 1820×2470

4300 14001820×2470

9.2 32 100D 900 2000×2470 2000×2470

P15-CO105D

1.75800 1820×2470

4300 14501820×2470

10.0 32 100D 900 2000×2470 2000×2470

P15-CO120D

2800 1820×2470

4350 16501820×2470

11.4 40 125D 900 2000×2470 2000×2470

P15-CO150D

2.5800 1820×2470

4350 21001820×2470

14.3 40 125D 900 2000×2470 2000×2470

Counterweight at side

Hook (By general contractor)

Mac

hine

room

hei

ght M

.H

Dust-proofed(By general contractor)

Doo

r he

ight

Ove

rhea

d O

H

Top floor

Hoistway lighting(By general contractor)

Pit waterproof(By general contractor)

Ladder(By general contractor)

Pit inspection receptacle(By general contractor)

Bottom floor

Trav

el

Tota

l hei

ght

Pit

dep

th P

Hoistway section

Machine room plan

Machine room width M.A

Mac

hine

room

dep

th M

.B

Machine room door(With key)

(By general contractor)600Wx1800H

Vent

ilatio

n fa

n(B

y g

ener

al c

ontr

acto

r) Win

dow

(By

gen

eral

con

trac

tor)

Pow

er S

witc

h(B

y g

ener

al c

ontr

acto

r)

Lighting switchinspection receptacle

(By general contractor)

Door opening width W

Hoistway width X

Car inside width A

Hoistway plan

Hoi

stw

ay d

epth

Y

Car

insi

de

dep

th B

Hoistwaycenterline Car centerline

Control panel

Specifications

capacity(kw)

service stops (s)

Nos.ofPerson

Capacity(kg)

Speed(m/s)

Type

Internal (A x B)

Cage size(mm)

X x Y OH P

W(mm)

Door width Hoistway size (mm)

M.HM.A x M.B

Machine room dimensoins (mm) Motor Max. Max.

travel(m)

TB408_[001-012]_TC.indd 3 09.9.17 10:29:51 AM

Page 4: ELCOSMO E - toshiba-elevator.co.jp · elcosmo toshiba compact machine room elevators ... p11-co96 w 1.6 800 1945×1770 4300 1400 1945×1770 7.3 32 100 w 900 2050×1770 2050×1770

P17-CO60W

17 1150

1

1800×1500

1000 2500×19804050 1300

2500×1980

2000

7.3 24 60W 1100 2600×1980 2600×1980

P17-CO96W

1.61000 2500×1980

4300 14002500×1980

11.6 32 100W 1100 2600×1980 2600×1980

P17-CO105W

1.751000 2500×1980

4300 14502500×1980

12.6 32 100W 1100 2600×1980 2600×1980

P17-CO120W

21000 2500×1980

4350 16502500×1980

14.4 40 125W 1100 2600×1980 2600×1980

P17-CO150W

2.51000 2500×1980

4700 21002500×1980

18.0 40 125W 1100 2600×1980 2600×1980

P19-2S60 D

19 1275

1

1200×2450 1100 2100×3000

4050 1300

2100×3000 2200

8.7 24 60

P19-2S96 D 1.6 4300 1400 14.0 32 100

P19-2S105 D 1.75 4300 1450 16.0 32 100

P19-2S120 D 2 4350 1650 18.0 40 125

P19-2S150 D 2.5 4700 2100 20.0 40 125

P24-2S60 D

24 1600

1

1400×2500 1200 2300×3050

4050 1300

2300×3050 2200

10.0 24 60

P24-2S96 D 1.6 4300 1400 16.0 32 100

P24-2S105 D 1.75 4300 1450 18.0 32 100

P24-2S120 D 2 4350 1650 20.0 40 125

P24-2S150 D 2.5 4700 2100 24.0 40 125

Note:• Hoistway dimensions are the minimum dimension after the building work.• Hoistway dimensions are the minimum requirement.• The hoistway structure wall must be 150mm thick or more.• Piping, wiring and cables not related to elevator are prohibited inside the hoistway.• In case that more than one (simplex) elevator is required, please contact us.• If the size of the hoistway is greater than above sizes, OH will be larger, please contact us.• Example: P17W W: Wide car D: Deep car

Motor capacity

(kw)

Max. service stops (s)

Max. travel

(m)X x Y OH P

Hoistway size (mm)

M.A x M.B M.H

Machine room dimensoins (mm)Door width

W(mm)

Nos.ofPerson

Capacity(kg)

Speed(m/s)

Type

Internal (A x B)

Cage size(mm)

Hoistway layout

3 4

Doo

r he

ight

Hook (By general contractor)

Ove

rhea

d O

HM

achin

e ro

om h

eight

M.H

Hoistway lighting(By general contractor)

Pit waterproof(By general contractor)

Ladder(By general contractor)

Pit inspection receptacle(By general contractor)

Bottom floor

Top floor

Center opening doorhoistway plan(Type: P15W)

Hoistwaycenterline

Dust-proofed(By general contractor)

Door opening width W

Hoistway width X

Hoi

stw

ay d

epth

Y

Car

insi

de

dep

th B

Car inside width A

Hoistwaycenterline

Carcenterline

Hoistway section

Trav

el

Tota

l hei

ght

Two panel slide door Hoistway plan

(Type: P17D, P21D)

Machine room plan

Win

dow

(By

gen

eral

con

trac

tor)

Pow

er s

witc

h(B

y g

ener

al c

ontr

acto

r)

Machine room width M.A

Machine room door(With key)

(By general contractor)600W×1800H

Lighting switchinspection receptacle

(By general contractor)

Mac

hine

room

dep

th M

.B

Vent

ilatio

n fa

n(B

y g

ener

al c

ontr

acto

r)

Hoi

stw

ay d

epth

Y

Car

insi

de

dep

th B

Door opening width W

Hoistway width X

Car inside width A

Pit

dep

th P

Control panel

Carcenterline

Specifications

Counterweight at side

TB408_[001-012]_TC.indd 4 09.9.17 10:29:55 AM

Page 5: ELCOSMO E - toshiba-elevator.co.jp · elcosmo toshiba compact machine room elevators ... p11-co96 w 1.6 800 1945×1770 4300 1400 1945×1770 7.3 32 100 w 900 2050×1770 2050×1770

P17-CO60W

17 1150

1

1800×1500

1000 2500×19804050 1300

2500×1980

2000

7.3 24 60W 1100 2600×1980 2600×1980

P17-CO96W

1.61000 2500×1980

4300 14002500×1980

11.6 32 100W 1100 2600×1980 2600×1980

P17-CO105W

1.751000 2500×1980

4300 14502500×1980

12.6 32 100W 1100 2600×1980 2600×1980

P17-CO120W

21000 2500×1980

4350 16502500×1980

14.4 40 125W 1100 2600×1980 2600×1980

P17-CO150W

2.51000 2500×1980

4700 21002500×1980

18.0 40 125W 1100 2600×1980 2600×1980

P19-2S60 D

19 1275

1

1200×2450 1100 2100×3000

4050 1300

2100×3000 2200

8.7 24 60

P19-2S96 D 1.6 4300 1400 14.0 32 100

P19-2S105 D 1.75 4300 1450 16.0 32 100

P19-2S120 D 2 4350 1650 18.0 40 125

P19-2S150 D 2.5 4700 2100 20.0 40 125

P24-2S60 D

24 1600

1

1400×2500 1200 2300×3050

4050 1300

2300×3050 2200

10.0 24 60

P24-2S96 D 1.6 4300 1400 16.0 32 100

P24-2S105 D 1.75 4300 1450 18.0 32 100

P24-2S120 D 2 4350 1650 20.0 40 125

P24-2S150 D 2.5 4700 2100 24.0 40 125

Note:• Hoistway dimensions are the minimum dimension after the building work.• Hoistway dimensions are the minimum requirement.• The hoistway structure wall must be 150mm thick or more.• Piping, wiring and cables not related to elevator are prohibited inside the hoistway.• In case that more than one (simplex) elevator is required, please contact us.• If the size of the hoistway is greater than above sizes, OH will be larger, please contact us.• Example: P17W W: Wide car D: Deep car

Motor capacity

(kw)

Max. service stops (s)

Max. travel

(m)X x Y OH P

Hoistway size (mm)

M.A x M.B M.H

Machine room dimensoins (mm)Door width

W(mm)

Nos.ofPerson

Capacity(kg)

Speed(m/s)

Type

Internal (A x B)

Cage size(mm)

Hoistway layout

3 4

Doo

r he

ight

Hook (By general contractor)

Ove

rhea

d O

HM

achin

e ro

om h

eight

M.H

Hoistway lighting(By general contractor)

Pit waterproof(By general contractor)

Ladder(By general contractor)

Pit inspection receptacle(By general contractor)

Bottom floor

Top floor

Center opening doorhoistway plan(Type: P15W)

Hoistwaycenterline

Dust-proofed(By general contractor)

Door opening width W

Hoistway width X

Hoi

stw

ay d

epth

Y

Car

insi

de

dep

th B

Car inside width A

Hoistwaycenterline

Carcenterline

Hoistway section

Trav

el

Tota

l hei

ght

Two panel slide door Hoistway plan

(Type: P17D, P21D)

Machine room plan

Win

dow

(By

gen

eral

con

trac

tor)

Pow

er s

witc

h(B

y g

ener

al c

ontr

acto

r)

Machine room width M.A

Machine room door(With key)

(By general contractor)600W×1800H

Lighting switchinspection receptacle

(By general contractor)

Mac

hine

room

dep

th M

.B

Vent

ilatio

n fa

n(B

y g

ener

al c

ontr

acto

r)

Hoi

stw

ay d

epth

Y

Car

insi

de

dep

th B

Door opening width W

Hoistway width X

Car inside width A

Pit

dep

th P

Control panel

Carcenterline

Specifications

Counterweight at side

TB408_[001-012]_TC.indd 5 09.9.17 10:29:58 AM

Page 6: ELCOSMO E - toshiba-elevator.co.jp · elcosmo toshiba compact machine room elevators ... p11-co96 w 1.6 800 1945×1770 4300 1400 1945×1770 7.3 32 100 w 900 2050×1770 2050×1770

P9-CO60W

9 600

1

1400×1100

800 1850×16804050 1300

1850×1680

2000

3.6 24 60W 900 1950×1680 1950×1680

P9-CO96W

1.6800 1850×1680

4300 14001850×1680

5.8 32 100W 900 1950×1680 1950×1680

P9-CO105W

1.75800 1850×1680

4300 14501850×1680

6.3 32 100W 900 1950×1680 1950×1680

P9-CO120W

2800 1950×1780

4350 16501950×1780

7.2 40 125W 900 2050×1780 2050×1780

P9-CO150W

2.5800 1950×1780

4350 21001950×1780

9.0 40 125W 900 2050×1780 2050×1780

P11-CO60W

11 750

1

1400×1350

800 1850×20004050 1300

1850×2000

2000

4.6 24 60W 900 1950×2000 1950×2000

P11-CO96W

1.6800 1850×2000

4300 14001850×2000

7.3 32 100W 900 1950×2000 1950×2000

P11-CO105W

1.75800 1850×2000

4300 14501850×2000

8.0 32 100W 900 1950×2000 1950×2000

P11-CO120W

2800 1950×2100

4350 16501950×2100

9.2 40 125W 900 2050×2100 2050×2100

P11-CO150W

2.5800 1950×2100

4350 21001950×2100

11.4 40 125W 900 2050×2100 2050×2100

P14-CO60W

14 950

1

1600×1400

900 2100×20504050 1300

2100×2050

2000

5.7 24 60W 1000 2200×2050 2200×2050

P14-C096W

1.6900 2100×2050

4300 14002100×2050

9.2 32 100W 1000 2200×2050 2200×2050

P14-CO105W

1.75900 2100×2050

4300 14502100×2050

10.0 32 100W 1000 2200×2050 2200×2050

P14-C0120W

2900 2200×2150

4350 16502200×2150

11.4 40 125W 1000 2300×2150 2300×2150

P14-CO150W

2.5900 2200×2150

4350 21002200×2150

14.3 40 125W 1000 2300×2150 2300×2150

Specifications

X x Y OH P M.A x M.B

Hoistway size (mm)Machine room

dimensoins (mm)

M.H

Motor capacity

(kw)

Max. service stops (s)

Max. travel

(m)

Nos.ofPerson

Capacity(kg)

Speed(m/s)

Type

Internal (A x B)

Door widthW

(mm)

Cage size(mm)

Hoistway layout

5 6

Ladder(By general contractor)

Pit inspection receptacle(By general contractor)

Bottom floor

Top floor

Trav

el

Hoistway plan

Door opening width W

Hoistway width X

Hoi

stw

ay d

epth

Y

Car

insi

de

dep

th B

Car inside width A

Con

trol p

anel

Vent

ilatio

n fa

n(B

y g

ener

al c

ontr

acto

r)

Win

dow

(By

gen

eral

con

trac

tor)

Power switch(By general contractor)

Lighting switchinspection receptacle

(By general contractor)

Machine room width M.A

Mac

hine

room

dep

th M

.B

Machine room door(With key)

(By general contractor)

600W×1800H

Machine room plan

Note:• Hoistway dimensions are the minimum dimension after the building work.• Hoistway dimensions are the minimum requirement.• The hoistway structure wall must be 150mm thick or more.• Piping, wiring and cables not related to elevator are prohibited inside the hoistway.• In case that more than one (simplex) elevator is required, please contact us.• If the size of the hoistway is greater than above sizes, OH will be larger, please contact us.• Example: P13W W: Wide car

Hook (By general contractor)

Mac

hine

room

hei

ght M

.H

Dust-proofed(By general contractor)

Doo

r he

ight

Ove

rhea

d O

H

Hoistway lighting(By general contractor)

Pit waterproof(By general contractor)

Tota

l hei

ght

Pit

dep

th P

Hoistway section

Counterweight at rear

TB408_[001-012]_TC.indd 6 09.9.17 10:30:02 AM

Page 7: ELCOSMO E - toshiba-elevator.co.jp · elcosmo toshiba compact machine room elevators ... p11-co96 w 1.6 800 1945×1770 4300 1400 1945×1770 7.3 32 100 w 900 2050×1770 2050×1770

P9-CO60W

9 600

1

1400×1100

800 1850×16804050 1300

1850×1680

2000

3.6 24 60W 900 1950×1680 1950×1680

P9-CO96W

1.6800 1850×1680

4300 14001850×1680

5.8 32 100W 900 1950×1680 1950×1680

P9-CO105W

1.75800 1850×1680

4300 14501850×1680

6.3 32 100W 900 1950×1680 1950×1680

P9-CO120W

2800 1950×1780

4350 16501950×1780

7.2 40 125W 900 2050×1780 2050×1780

P9-CO150W

2.5800 1950×1780

4350 21001950×1780

9.0 40 125W 900 2050×1780 2050×1780

P11-CO60W

11 750

1

1400×1350

800 1850×20004050 1300

1850×2000

2000

4.6 24 60W 900 1950×2000 1950×2000

P11-CO96W

1.6800 1850×2000

4300 14001850×2000

7.3 32 100W 900 1950×2000 1950×2000

P11-CO105W

1.75800 1850×2000

4300 14501850×2000

8.0 32 100W 900 1950×2000 1950×2000

P11-CO120W

2800 1950×2100

4350 16501950×2100

9.2 40 125W 900 2050×2100 2050×2100

P11-CO150W

2.5800 1950×2100

4350 21001950×2100

11.4 40 125W 900 2050×2100 2050×2100

P14-CO60W

14 950

1

1600×1400

900 2100×20504050 1300

2100×2050

2000

5.7 24 60W 1000 2200×2050 2200×2050

P14-C096W

1.6900 2100×2050

4300 14002100×2050

9.2 32 100W 1000 2200×2050 2200×2050

P14-CO105W

1.75900 2100×2050

4300 14502100×2050

10.0 32 100W 1000 2200×2050 2200×2050

P14-C0120W

2900 2200×2150

4350 16502200×2150

11.4 40 125W 1000 2300×2150 2300×2150

P14-CO150W

2.5900 2200×2150

4350 21002200×2150

14.3 40 125W 1000 2300×2150 2300×2150

Specifications

X x Y OH P M.A x M.B

Hoistway size (mm)Machine room

dimensoins (mm)

M.H

Motor capacity

(kw)

Max. service stops (s)

Max. travel

(m)

Nos.ofPerson

Capacity(kg)

Speed(m/s)

Type

Internal (A x B)

Door widthW

(mm)

Cage size(mm)

Hoistway layout

5 6

Ladder(By general contractor)

Pit inspection receptacle(By general contractor)

Bottom floor

Top floor

Trav

el

Hoistway plan

Door opening width W

Hoistway width X

Hoi

stw

ay d

epth

Y

Car

insi

de

dep

th B

Car inside width A

Con

trol p

anel

Vent

ilatio

n fa

n(B

y g

ener

al c

ontr

acto

r)

Win

dow

(By

gen

eral

con

trac

tor)

Power switch(By general contractor)

Lighting switchinspection receptacle

(By general contractor)

Machine room width M.A

Mac

hine

room

dep

th M

.B

Machine room door(With key)

(By general contractor)

600W×1800H

Machine room plan

Note:• Hoistway dimensions are the minimum dimension after the building work.• Hoistway dimensions are the minimum requirement.• The hoistway structure wall must be 150mm thick or more.• Piping, wiring and cables not related to elevator are prohibited inside the hoistway.• In case that more than one (simplex) elevator is required, please contact us.• If the size of the hoistway is greater than above sizes, OH will be larger, please contact us.• Example: P13W W: Wide car

Hook (By general contractor)

Mac

hine

room

hei

ght M

.H

Dust-proofed(By general contractor)

Doo

r he

ight

Ove

rhea

d O

H

Hoistway lighting(By general contractor)

Pit waterproof(By general contractor)

Tota

l hei

ght

Pit

dep

th P

Hoistway section

Counterweight at rear

TB408_[001-012]_TC.indd 7 09.9.17 10:30:05 AM

Page 8: ELCOSMO E - toshiba-elevator.co.jp · elcosmo toshiba compact machine room elevators ... p11-co96 w 1.6 800 1945×1770 4300 1400 1945×1770 7.3 32 100 w 900 2050×1770 2050×1770

Hoistway layout

7 8

P17-CO60W

17 1150

1

1800×1500

1000 2300×21904050 1300

2300×2190

2200

7.3 24 60W 1100 2450×2190 2450×2190

P17-CO96W

1.61000 2300×2190

4300 14002300×2190

11.6 32 100W 1100 2450×2190 2450×2190

P17-CO105W

1.751000 2300×2190

4300 14502300×2190

12.6 32 100W 1100 2450×2190 2450×2190

P17-CO120W

21000 2300×2190

4350 16502300×2190

14.4 40 125W 1100 2450×2190 2450×2190

P17-CO150W

2.51000 2300×2190

4700 21002300×2190

18.0 40 125W 1100 2450×2190 2450×2190

P19-CO60 W

19 1275

1

2000×1445 1100 2550×2145

4050 1300

2550×2145 2200

8.7 24 60

P19-CO96 W 1.6 4300 1400 14.0 32 100

P19-CO105 W 1.75 4300 1450 16.0 32 100

P19-CO120 W 2 4350 1650 18.0 40 125

P19-CO150 W 2.5 4700 2100 20.0 40 125

P20-CO60 W

20 1350

1

2000×1525 1100 2550×2250

4050 1300

2550×2250 2200

8.7 24 60

P20-CO96 W 1.6 4300 1400 14.0 32 100

P20-CO105 W 1.75 4300 1450 16.0 32 100

P20-CO120 W 2 4350 1650 18.0 40 125

P20-CO150 W 2.5 4700 2100 20.0 40 125

P24-CO60W

24 1600

1

2000×1750

1100 2550×24504050 1300

2550×2450

2200

10.0 24 60W 1200 2700×2450 2700×2450

P24-CO96W

1.61100 2550×2450

4300 14002550×2450

16.0 32 100W 1200 2700×2450 2700×2450

P24-CO105W

1.751100 2550×2450

4300 14502550×2450

18.0 32 100W 1200 2700×2450 2700×2450

P24-CO120W

21100 2550×2450

4350 16502550×2450

20.0 40 125W 1200 2700×2450 2700×2450

P24-CO150W

2.51100 2550×2450

4700 21002550×2450

24.0 40 125W 1200 2700×2450 2700×2450

P27-CO60 W

27 1800

1

2100×1800 1200 2700×2500

4050 1400

2700×2500 2200

12.0 24 60

P27-CO96 W 1.6 4300 1550 18.0 32 100

P27-CO105 W 1.75 4300 1650 20.0 32 100

P27-CO120 W 2 4350 1900 22.0 40 125

Machine room plan(P17W〜P24W)

Control panel

Vent

ilatio

n fa

n(B

y g

ener

al c

ontr

acto

r)

Win

dow

(By

gen

eral

con

trac

tor)

Power switch(By general contractor)

Lighting switchinspection receptacle

(By general contractor)

Machine room width M.A

Mac

hine

room

dep

th M

.B

Mac

hine

room

doo

r(W

ith k

ey)

(By

gen

eral

co

ntra

ctor

)60

0W×

1800

H

Doo

r he

ight

Ove

rhea

d O

H

Bottom floor

Top floor

Dust-proofed(By general contractor)

Door opening width W

Hoistway width X

Hoi

stw

ay d

epth

Y

Car

insi

de

dep

th B

Car inside width A

Con

trol p

anel

Vent

ilatio

n fa

n(B

y g

ener

al c

ontr

acto

r)

Win

dow

(By

gen

eral

con

trac

tor)

Power switch(By general contractor)

Lighting switchinspection receptacle

(By general contractor)

Mac

hine

room

dep

th M

.B

Machine room plan(P15W)

Machine room door(With key)

(By general contractor)

600W×1800H

Note:• Hoistway dimensions are the minimum dimension after the building work.• Hoistway dimensions are the minimum requirement.• The hoistway structure wall must be 150mm thick or more.• Piping, wiring and cables not related to elevator are prohibited inside the hoistway.• In case that more than one (simplex) elevator is required, please contact us.• If the size of the hoistway is greater than above sizes, OH will be larger, please contact us.• Example: P17W W: Wide car

Hook (By general contractor)

Mac

hine

room

hei

ght M

.H

Pit inspection receptacle(By general contractor)

Pit

dep

th P

Pit waterproof(By general contractor)

Hoistway lighting(By general contractor)

Trav

el

Tota

l hei

ght

Hoistway plan

Hoistway section

Ladder(By general contractor)

Specifications

M.A x M.B M.H

Machine room dimensoins (mm) Motor

capacity(kw)

Max. service stops (s)

Max. travel

(m)X x Y OH P

Door widthW

(mm)

Hoistway size (mm)Nos.ofPerson

Capacity(kg)

Speed(m/s)

Type

Internal (A x B)

Cage size(mm)

Counterweight at rear

TB408_[001-012]_TC.indd 8 09.9.17 10:30:09 AM

Page 9: ELCOSMO E - toshiba-elevator.co.jp · elcosmo toshiba compact machine room elevators ... p11-co96 w 1.6 800 1945×1770 4300 1400 1945×1770 7.3 32 100 w 900 2050×1770 2050×1770

Hoistway layout

7 8

P17-CO60W

17 1150

1

1800×1500

1000 2300×21904050 1300

2300×2190

2200

7.3 24 60W 1100 2450×2190 2450×2190

P17-CO96W

1.61000 2300×2190

4300 14002300×2190

11.6 32 100W 1100 2450×2190 2450×2190

P17-CO105W

1.751000 2300×2190

4300 14502300×2190

12.6 32 100W 1100 2450×2190 2450×2190

P17-CO120W

21000 2300×2190

4350 16502300×2190

14.4 40 125W 1100 2450×2190 2450×2190

P17-CO150W

2.51000 2300×2190

4700 21002300×2190

18.0 40 125W 1100 2450×2190 2450×2190

P19-CO60 W

19 1275

1

2000×1445 1100 2550×2145

4050 1300

2550×2145 2200

8.7 24 60

P19-CO96 W 1.6 4300 1400 14.0 32 100

P19-CO105 W 1.75 4300 1450 16.0 32 100

P19-CO120 W 2 4350 1650 18.0 40 125

P19-CO150 W 2.5 4700 2100 20.0 40 125

P20-CO60 W

20 1350

1

2000×1525 1100 2550×2250

4050 1300

2550×2250 2200

8.7 24 60

P20-CO96 W 1.6 4300 1400 14.0 32 100

P20-CO105 W 1.75 4300 1450 16.0 32 100

P20-CO120 W 2 4350 1650 18.0 40 125

P20-CO150 W 2.5 4700 2100 20.0 40 125

P24-CO60W

24 1600

1

2000×1750

1100 2550×24504050 1300

2550×2450

2200

10.0 24 60W 1200 2700×2450 2700×2450

P24-CO96W

1.61100 2550×2450

4300 14002550×2450

16.0 32 100W 1200 2700×2450 2700×2450

P24-CO105W

1.751100 2550×2450

4300 14502550×2450

18.0 32 100W 1200 2700×2450 2700×2450

P24-CO120W

21100 2550×2450

4350 16502550×2450

20.0 40 125W 1200 2700×2450 2700×2450

P24-CO150W

2.51100 2550×2450

4700 21002550×2450

24.0 40 125W 1200 2700×2450 2700×2450

P27-CO60 W

27 1800

1

2100×1800 1200 2700×2500

4050 1400

2700×2500 2200

12.0 24 60

P27-CO96 W 1.6 4300 1550 18.0 32 100

P27-CO105 W 1.75 4300 1650 20.0 32 100

P27-CO120 W 2 4350 1900 22.0 40 125

Machine room plan(P17W〜P24W)

Control panel

Vent

ilatio

n fa

n(B

y g

ener

al c

ontr

acto

r)

Win

dow

(By

gen

eral

con

trac

tor)

Power switch(By general contractor)

Lighting switchinspection receptacle

(By general contractor)

Machine room width M.A

Mac

hine

room

dep

th M

.B

Mac

hine

room

doo

r(W

ith k

ey)

(By

gen

eral

co

ntra

ctor

)60

0W×

1800

H

Doo

r he

ight

Ove

rhea

d O

H

Bottom floor

Top floor

Dust-proofed(By general contractor)

Door opening width W

Hoistway width X

Hoi

stw

ay d

epth

Y

Car

insi

de

dep

th B

Car inside width A

Con

trol p

anel

Vent

ilatio

n fa

n(B

y g

ener

al c

ontr

acto

r)

Win

dow

(By

gen

eral

con

trac

tor)

Power switch(By general contractor)

Lighting switchinspection receptacle

(By general contractor)

Mac

hine

room

dep

th M

.B

Machine room plan(P15W)

Machine room door(With key)

(By general contractor)

600W×1800H

Note:• Hoistway dimensions are the minimum dimension after the building work.• Hoistway dimensions are the minimum requirement.• The hoistway structure wall must be 150mm thick or more.• Piping, wiring and cables not related to elevator are prohibited inside the hoistway.• In case that more than one (simplex) elevator is required, please contact us.• If the size of the hoistway is greater than above sizes, OH will be larger, please contact us.• Example: P17W W: Wide car

Hook (By general contractor)

Mac

hine

room

hei

ght M

.H

Pit inspection receptacle(By general contractor)

Pit

dep

th P

Pit waterproof(By general contractor)

Hoistway lighting(By general contractor)

Trav

el

Tota

l hei

ght

Hoistway plan

Hoistway section

Ladder(By general contractor)

Specifications

M.A x M.B M.H

Machine room dimensoins (mm) Motor

capacity(kw)

Max. service stops (s)

Max. travel

(m)X x Y OH P

Door widthW

(mm)

Hoistway size (mm)Nos.ofPerson

Capacity(kg)

Speed(m/s)

Type

Internal (A x B)

Cage size(mm)

Counterweight at rear

TB408_[001-012]_TC.indd 9 09.9.17 10:30:13 AM

Page 10: ELCOSMO E - toshiba-elevator.co.jp · elcosmo toshiba compact machine room elevators ... p11-co96 w 1.6 800 1945×1770 4300 1400 1945×1770 7.3 32 100 w 900 2050×1770 2050×1770

P15-CO60 D2

15 1000

1

1100×2100 800 1820×2610

4050 1300

1820×2610 2000

5.7

P15-CO96 D2 1.6 4300 1400 9.2

P15-CO105 D2 1.75 4300 1450 10.0

P15-CO120 D2 2 4350 1650 11.4

P15-CO150 D2 2.5 4350 2100 14.3

P24-2S60 D2

24 1600

1

1400×2500 1200 2300×3170

4050 1300

2300×3170 2200

10.0

P24-2S96 D2 1.6 4300 1400 16.0

P24-2S105 D2 1.75 4300 1450 18.0

P24-2S120 D2 2 4350 1650 20.0

P24-2S150 D2 2.5 4700 2100 24.0

※1

※1

Please contact us.

Hoistway layout

9 10

Ladder(By general contractor)

Bottom floor

Top floor

Front and rear openinghoistway section

Dust-proofed(By general contractor)

Hoi

stw

ay d

epth

Y

Front and rear openinghoistway plan(Type: P21D2)

Front and rear openinghoistway plan(Type: P13D2)

Door opening width W

Hoistway width X

Car

insi

de

dep

th B

Car inside width A

Hoistwaycenterline

Carcenterline

Machine room width M.A

Mac

hine

room

dep

th M

.B

Vent

ilatio

n fa

n(B

y g

ener

al c

ontr

acto

r)

Control panel

Win

dow

(By

gen

eral

con

trac

tor)

Pow

er s

witc

h(B

y g

ener

al c

ontr

acto

r)

Lighting switchinspection receptacle

(By general contractor)

Note:• Hoistway dimensions are the minimum dimension after the building work.• Hoistway dimensions are the minimum requirement.• The hoistway structure wall must be 150mm thick or more.• Piping, wiring and cables not related to elevator are prohibited inside the hoistway.• In case that more than one (simplex) elevator is required, please contact us.• If the size of the hoistway is greater than above sizes, OH will be larger, please contact us.• The front and rear opening floor are less than 8 floor• Example: P13D2 D2:Front and rear opening door deep car

Hook (By general contractor)

Mac

hine

room

hei

ght M

.HO

verh

ead

OH

Doo

r he

ight

Trav

el

Tota

l hei

ght

Pit inspection receptacle(By general contractor)

Pit

dep

th P

Pit waterproof(By general contractor)

Hoistway lighting(By general contractor)

Hoi

stw

ay d

epth

Y

Car

insi

de

dep

th B

Door opening width W

Hoistway width X

Car inside width A

Specifications

X x Y OH P

Hoistway size (mm)

M.A x M.B M.H

Machine room dimensoins (mm) Motor

capacity(kw)

Max. service stops (s)

Max. travel

(m)

Nos.ofPerson

Capacity(kg)

Speed(m/s)

Type

Internal (A x B)

Door widthW

(mm)

Cage size(mm)

Front and rear opening door (Counterweight at side)

TB408_[001-012]_TC.indd 10 09.9.17 10:30:16 AM

Page 11: ELCOSMO E - toshiba-elevator.co.jp · elcosmo toshiba compact machine room elevators ... p11-co96 w 1.6 800 1945×1770 4300 1400 1945×1770 7.3 32 100 w 900 2050×1770 2050×1770

P15-CO60 D2

15 1000

1

1100×2100 800 1820×2610

4050 1300

1820×2610 2000

5.7

P15-CO96 D2 1.6 4300 1400 9.2

P15-CO105 D2 1.75 4300 1450 10.0

P15-CO120 D2 2 4350 1650 11.4

P15-CO150 D2 2.5 4350 2100 14.3

P24-2S60 D2

24 1600

1

1400×2500 1200 2300×3170

4050 1300

2300×3170 2200

10.0

P24-2S96 D2 1.6 4300 1400 16.0

P24-2S105 D2 1.75 4300 1450 18.0

P24-2S120 D2 2 4350 1650 20.0

P24-2S150 D2 2.5 4700 2100 24.0

※1

※1

Please contact us.

Hoistway layout

9 10

Ladder(By general contractor)

Bottom floor

Top floor

Front and rear openinghoistway section

Dust-proofed(By general contractor)

Hoi

stw

ay d

epth

Y

Front and rear openinghoistway plan(Type: P21D2)

Front and rear openinghoistway plan(Type: P13D2)

Door opening width W

Hoistway width X

Car

insi

de

dep

th B

Car inside width A

Hoistwaycenterline

Carcenterline

Machine room width M.A

Mac

hine

room

dep

th M

.B

Vent

ilatio

n fa

n(B

y g

ener

al c

ontr

acto

r)

Control panel

Win

dow

(By

gen

eral

con

trac

tor)

Pow

er s

witc

h(B

y g

ener

al c

ontr

acto

r)

Lighting switchinspection receptacle

(By general contractor)

Note:• Hoistway dimensions are the minimum dimension after the building work.• Hoistway dimensions are the minimum requirement.• The hoistway structure wall must be 150mm thick or more.• Piping, wiring and cables not related to elevator are prohibited inside the hoistway.• In case that more than one (simplex) elevator is required, please contact us.• If the size of the hoistway is greater than above sizes, OH will be larger, please contact us.• The front and rear opening floor are less than 8 floor• Example: P13D2 D2:Front and rear opening door deep car

Hook (By general contractor)

Mac

hine

room

hei

ght M

.HO

verh

ead

OH

Doo

r he

ight

Trav

el

Tota

l hei

ght

Pit inspection receptacle(By general contractor)

Pit

dep

th P

Pit waterproof(By general contractor)

Hoistway lighting(By general contractor)

Hoi

stw

ay d

epth

Y

Car

insi

de

dep

th B

Door opening width W

Hoistway width X

Car inside width A

Specifications

X x Y OH P

Hoistway size (mm)

M.A x M.B M.H

Machine room dimensoins (mm) Motor

capacity(kw)

Max. service stops (s)

Max. travel

(m)

Nos.ofPerson

Capacity(kg)

Speed(m/s)

Type

Internal (A x B)

Door widthW

(mm)

Cage size(mm)

Front and rear opening door (Counterweight at side)

TB408_[001-012]_TC.indd 11 09.9.17 10:30:19 AM

Page 12: ELCOSMO E - toshiba-elevator.co.jp · elcosmo toshiba compact machine room elevators ... p11-co96 w 1.6 800 1945×1770 4300 1400 1945×1770 7.3 32 100 w 900 2050×1770 2050×1770

ELCOSMOTOSHIBA COMPACT MACHINE ROOM ELEVATORS

Safety Cautions • Observance of relevant laws / regulations are required.

• Read the entire “Instruction Manual” carefully before use, for important information about safety, handling and operation.

• The data given in this catalog are subject to change without notice.

Printed in Japan

5-27, Kitashinagawa 6-chome, Shinagawa-ku,Tokyo 141-0001 JapanPHONE: +81-3-5423-3389 FAX: +81-3-5423-2746

GK-F1362(0)-09.09 300-09.09(XW)

TB408_[001-012]_TC.indd 12 09.9.17 10:30:27 AM