136
General Specifications <<Contents>> <<Index>> EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, EJXC40A Diaphragm Seal System Yokogawa Electric Corporation 2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 Japan Tel.: 81-422-52-5690 Fax.: 81-422-52-2018 GS 01C25W01-01EN GS 01C25W01-01EN © Copylight May 2016 5th Edition Nov. 2019 [Diaphragm Seal System] Diaphragm Seal System can be used to measure liquid, gas, or steam flow as well as liquid level, density, and pressure. Diaphragm seals are used to prevent process medium form entering directly into the pressure-sensing assembly of the differential or Gauge pressure transmitter. Application which is suitable for diaphragm seal system For measuring the flow of ; • high/low temperature fluids • highly corrosive/high viscosity fluids • the fluids which may cause clogging of impulse piping in the low temperature • toxic fluids • the fluids containing suspended solids which are deposited in the impulse piping and may cause clogging. Venting/draining can be operated by installing the flushing connection ring, Refer to GS as of the table below for Fieldbus communication type and PROFIBUS PA communication type for the items marked with “◊.” Communication Type GS No. EJX FOUNDATION Fieldbus GS 01C25T02-01EN PROFIBUS PA GS 01C25T04-01EN EJA FOUNDATION Fieldbus GS 01C31T02-01EN PROFIBUS PA GS 01C31T04-01EN The codes of diaphragm seal system represent a seal system type. CE and other standard certification are acquired for each transmitter section. Diaphragm Seal System Applicable Transmitter EJXC80A EJAC80E EJX110A, EJX430A EJA110E, EJA430E EJXC81A EJAC81E EJX310A, EJA310E EJXC50A EJAC50E EJX530A, EJA530E EJXC40A EJX530A Diaphragm Seal System Diaphragm Seal System (Inner Diaphragm type) Direct Mounted Diaphragm Seal System Digital Remote Sensor Diaphragm Seal System Hygienic Diaphragm Seal System Adapter connection type Flange connection type Absolute Pressure Diaphragm Seal System

EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

GeneralSpecifications

<<Contents>> <<Index>>

EJXC80A, EJAC80EEJXC81A, EJAC81EEJXC50A, EJAC50E, EJXC40ADiaphragm Seal System

Yokogawa Electric Corporation2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 JapanTel.: 81-422-52-5690 Fax.: 81-422-52-2018

GS01C25W01-01EN

GS 01C25W01-01EN© Copylight May 20165th Edition Nov. 2019

[DiaphragmSealSystem]Diaphragm Seal System can be used to measure liquid, gas, or steam fl ow as well as liquid level, density, and pressure. Diaphragm seals are used to prevent process medium form entering directly into the pressure-sensing assembly of the differential or Gauge pressure transmitter. Application which is suitable for diaphragm seal system

Formeasuringtheflowof;•high/lowtemperaturefluids•highlycorrosive/highviscosityfluids•thefluidswhichmaycausecloggingofimpulsepiping

in the low temperature•toxicfluids•thefluidscontainingsuspendedsolidswhichare

deposited in the impulse piping and may cause clogging.

Venting/drainingcanbeoperatedbyinstallingtheflushingconnectionring,

RefertoGSasofthetablebelowforFieldbuscommunication type and PROFIBUS PA communicationtypefortheitemsmarkedwith“◊.”

CommunicationType GSNo.EJX FOUNDATIONFieldbus GS 01C25T02-01EN

PROFIBUS PA GS 01C25T04-01EN

EJA FOUNDATIONFieldbus GS 01C31T02-01EN

PROFIBUS PA GS 01C31T04-01EN

Thecodesofdiaphragmsealsystemrepresentasealsystem type.CEandotherstandardcertificationareacquiredforeach transmitter section.

DiaphragmSealSystem ApplicableTransmitterEJXC80AEJAC80E

EJX110A, EJX430AEJA110E, EJA430E

EJXC81AEJAC81E

EJX310A, EJA310E

EJXC50AEJAC50E

EJX530A, EJA530E

EJXC40A EJX530A

Diaphragm Seal System

Diaphragm Seal System (Inner Diaphragm type)

Direct Mounted Diaphragm Seal System

Digital Remote Sensor Diaphragm Seal System

Hygienic Diaphragm Seal System

Adapter connection type Flange connection type

AbsolutePressureDiaphragm Seal System

Page 2: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

2

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Sep. 27, 2018-00

DiaphragmSealSystemDiaphragmSealSystemconsistsofgaugepressureordifferentialpressuretransmitterwithoneortwodiaphragmseal.Suitableforvariouskindsofpressuremeasurement.

Transmitter DiaphragmSeal

SealSystemLocationHighPressure

SideLowPressure

Side

DifferentialPressure Transmitter

Flanged/HygienicDiaphragmSeal

Remote Seal Remote SealRemote Seal -

- Remote SealDirect Mount Remote Seal

Gauge Pressure Transmitter Remote Seal -

DifferentialPressure Transmitter

CompensatingCapillaryType*2

Direct Mount

Remote Seal with compensation capillary

-:Notapplicable

ApplicableProducts(Transmitter)*1

•DifferentialPressureTransmitter EJX110A: GS01C25B01-01EN EJA110E: GS01C31B01-01EN•GaugePressureTransmitter EJX430A: GS01C25E01-01EN EJA430E: GS01C31E01-01EN

Processconnectionsize•FlushFlangedSeal 11/2-inch(40mm),2-inch(50mm),3-inch(80mm)•ExtendedFlangedSeal 3-inch (80 mm), 4-inch (100 mm)•InnerDiaphragmSeal,AdapterConnectionType 1/2-inch(15mm),3/4-inch(20mm),1-inch(25mm)•InnerDiaphragmSeal,FlangeConnectionType 1/2-inch(15mm),3/4-inch(20mm),1-inch(25mm)•FlushHygienicSeal(ISOClampSeal) ISO51, ISO76.1, ISO101.6•ExtendedHygienicSeal ISO76.1, ISO101.6

Features•Highperformance,highaccuracyandhighreliability.•Hightemperatureandhighvacuumuse(0.013kPaabs~)

•Fastresponse:200ms•Segmentsignalcharacterizer

CompensatingCapillaryDesignCompensation capillary type has a compensating capillarytohelpbalancethevolumeandtemperatureofthefillfluidsbetweenhighandlowpressuresidecapillaries.Thissolutionreducestheinfluenceofambienttemperaturedriftwhetheritiscausedbyswingsday-to-night, season-to-season, or shady-to-sunny.

*1: Forthedetailsofeachproduct,pleaserefertotheGeneralSpecificationsofeachmodel.

*2: ApplicableforFlangedDiaphragmSeal.

Diaphragm Seal SystemGauge Pressure Transmitter

DifferentialPressureTransmitter

Diaphragm Seal System (Inner Diaphragm type)Flange connection type

Diaphragm Seal System (Hygienic type)

Page 3: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

3<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Sep. 27, 2018-00

AbsolutePressureDiaphragmSealSystem

DiaphragmSealSystemconsistsofabsolutepressuretransmitterwithasinglediaphragmseal.Suitableforvariouskindsofpressuremeasurement.

Transmitter DiaphragmSeal

SealSystemLocationHighPressure

SideLowPressure

SideAbsolutePressure Transmitter

Flanged Diaphragm Seal

-

:Applicable,-:Notapplicable

ApplicableProducts(Transmitter)*1

•AbsolutePressureTransmitter EJX310A: GS01C25D01-01EN EJA310E: GS01C31D01-01EN

Processconnectionsize•FlushFlangedSeal 11/2-inch(40mm),2-inch(50mm),3-inch(80mm)•ExtendedFlangedSeal 3-inch (80 mm), 4-inch (100 mm)•InnerDiaphragmSeal,AdapterConnectionType 1/2-inch(15mm),3/4-inch(20mm),1-inch(25mm)•InnerDiaphragmSeal,FlangeConnectionType 1/2-inch(15mm),3/4-inch(20mm),1-inch(25mm)

Features•Highperformance,highaccuracyandhighreliability.•Hightemperatureandhighvacuumuse(0.013kPaabs~)

•Fastresponse:200ms•Segmentsignalcharacterizer

AbsolutePressureDiaphragmSealSystem

Adapter connection type

AbsolutePressureDiaphragmSealSystem(Inner Diaphragm type)

*1: Forthedetailsofeachproduct,pleaserefertotheGeneralSpecificationsofeachmodel.

Page 4: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

4

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Sep. 27, 2018-00

DirectMountedDiaphragmSealSystem

DirectMountedDiaphragmSealSystemconsistsofgaugepressureordifferentialpressuretransmitterwitha single direct mount diaphragm seal. Suitableforvariouskindsofpressuremeasurement.

Transmitter DiaphragmSeal

SealSystemLocationHighPressure

SideLowPressure

SideDifferentialPressure Transmitter

Direct Mount Flanged Hygienic Diaphragm Seal

-

Gauge Pressure Transmitter -

:Applicable,-:Notapplicable

ApplicableProducts(Transmitter)*1

•DifferentialPressureTransmitter EJX110A: GS01C25B01-01EN EJA110E: GS01C31B01-01EN•GaugePressureTransmitter EJX530A: GS01C25F01-01EN EJA530E: GS01C31F01-01EN

Processconnectionsize•FlushFlangedSeal 11/2-inch(40mm),2-inch(50mm),3-inch(80mm)•ExtendedFlangedSeal 3-inch (80 mm), 4-inch (100 mm)•FlushHygienicSeal(ISOClampSeal)*2 ISO76.1, ISO101.6•ExtendedHygienicSeal*2 ISO76.1, ISO101.6•FlushHygienicSeal(ISOClampSeal) ISO51*2, ISO76.1, ISO101.6•ExtendedHygienicSeal ISO51*2, ISO76.1, ISO101.6

Features•Highperformance,highaccuracyandhighreliability.•Fastresponse:120ms

Direct Mount Hygienic Diaphragm Seal System

Direct Mount Flanged Diaphragm Seal System

*1: Forthedetailsofeachproduct,pleaserefertotheGeneralSpecificationsofeachmodel.

*2: ApplicableforEJX110AandEJA110E.

Page 5: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

5<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Nov. 7, 2016-00

*1: Forthedetailsofeachproduct,pleaserefertotheGeneralSpecificationsofeachmodel.

DigitalRemoteSensoredDiaphragmSealSystem

Digital Remote Sensor (DRS) Transmitter connects two pressure sensors, high pressure side (master) and low pressure side (slave) in a remote location, with DRS dedicatedcommunicationcabletomeasuredifferentialpressure.

Transmitter DiaphragmSeal

SealSystemLocationMaster(High

PressureSide)

Slave(LowPressure

Side)

Digital Remote Sensor

Direct MountFlanged/HygienicDiaphragm Seal

S

S

:Applicable,S:ScrewMount

ApplicableProducts(Transmitter)*1

•DigitalRemoteSensorTransmitter EJXC40A: GS 01C25W05-01EN

Processconnectionsize•FlushFlangedSeal 11/2-inch(40mm),2-inch(50mm),3-inch(80mm)•ExtendedFlangedSeal 3-inch (80 mm), 4-inch (100 mm)•FlushHygienicSeal(ISOClampSeal) ISO76.1, ISO101.6•ExtendedHygienicSeal ISO76.1, ISO101.6

Features•Highperformance,highaccuracyandhighreliability•Suitableforlevelmeasurementofatalltank. DRScablelength(maximum):45m•Fastresponse:250ms•Segmentsignalcharacterizer

Digital Remote Sensor Hygienic Mounted Diaphragm Seal System

Digital Remote SensorFlange Mounted Diaphragm Seal System

Page 6: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

6

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Nov. 7, 2016-00

DiaphragmSealSystem

RemoteMountFlangedDiaphragmSeal

Model ProcessconnectionStyle Usage Processconnectionsize

(Processflangesize)Capillary

ConnectionStyle

F01E.ai

C80FW Raisedface(RF)Flush type

general use 3-inch (80 mm)2-inch (50 mm)

Sideofdiaphragmseal unit

F02E.ai

C80FW Ring joint (RJ)Flush type

general use 3-inch (80 mm)2-inch (50 mm)

Sideofdiaphragmseal unit

F03E.ai

C80FW Raisedface(RF)Flush type

general use 3-inch (80 mm)2-inch (50 mm)

Backofdiaphragmseal unit

F04E.ai

C80FW Raisedface(RF)Flush type

high vacuum use 3-inch (80 mm)2-inch (50 mm)

Sideofdiaphragmseal unit

F05E.ai

C80FW Raisedface(RF)Flush type

general use 11/2-inch(40mm) Sideofdiaphragmseal unit

F06E.ai

C80FW Raisedface(RF)Flush type

high vacuum use 11/2-inch(40mm) Sideofdiaphragmseal unit

F07E.ai

C80FE Raisedface(RF)Extended type

general use 4-inch (100 mm)3-inch (80 mm)

Backofdiaphragmseal unit

F08E.ai

C80FE Raisedface(RF)Extended type

high vacuum use 4-inch (100 mm)3-inch (80 mm)

Backofdiaphragmseal unit

Page 7: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

7<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Nov. 7, 2016-00

RemoteMountFlangedDiaphragmSeal(InnerDiaphragmtype)*1

Model ProcessconnectionStyle Usage Processconnectionsize

(Processflangesize)Capillary

ConnectionStyle

F09E.ai

C81FA C82FA

Raisedface(RF) Adapter connection type

general use 1/2-inch(15mm) 3/4-inch(20mm) 1-inch (25 mm)

Backofdiaphragmseal unit

F10E.ai

C81FA C82FA

Ring joint (RJ) Adapter connection type

general use 1/2-inch(15mm) 3/4-inch(20mm) 1-inch (25 mm)

Backofdiaphragmseal unit

F11E.ai

C81FD C82FD

Raisedface(RF) Flange connection type

general use 1/2-inch(15mm) 3/4-inch(20mm) 1-inch (25 mm)

Backofdiaphragmseal unit

F12E.ai

C81FD C82FD

Ring joint (RJ) Flange connection type

general use 1/2-inch(15mm) 3/4-inch(20mm) 1-inch (25 mm)

Backofdiaphragmseal unit

F13E.ai

C81FA C82FA

Raisedface(RF) Adapter connection type

high vacuum use 1/2-inch(15mm) 3/4-inch(20mm) 1-inch (25 mm)

Backofdiaphragmseal unit

F14E.ai

C81FA C82FA

Ring joint (RJ) Adapter connection type

high vacuum use 1/2-inch(15mm) 3/4-inch(20mm) 1-inch (25 mm)

Backofdiaphragmseal unit

F15E.ai

C81FD C82FD

Raisedface(RF) Flange connection type

high vacuum use 1/2-inch(15mm) 3/4-inch(20mm) 1-inch (25 mm)

Backofdiaphragmseal unit

F16E.ai

C81FD C82FD

Ring joint (RJ) Flange connection type

high vacuum use 1/2-inch(15mm) 3/4-inch(20mm) 1-inch (25 mm)

Backofdiaphragmseal unit

*1: C81FA, C81FD: Bundled capillary type (1 m separated)

Page 8: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

8

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Sep. 27, 2018-00

DirectMountFlangedDiaphragmSeal

Model Processconnectionstyle

Processconnectionsize(Processflangesize)

F17E.ai

C20FW Raisedface(RF) Flush type

3-inch (80 mm) 2-inch (50 mm)

F18E.ai

C20FW Raisedface(RF) Flush type

11/2-inch(40mm)

F19E.ai

C20FE Raisedface(RF) Extended type

4-inch (100 mm) 3-inch (80 mm)

RemoteMountHygienicDiaphragmSeal

Model Processconnectionstyle Processconnectionsize Capillary

ConnectionStyle

F20E.ai

C70SW ISO clamp Flush type

ISO51 ISO76.1 ISO101.6

Backofdiaphragmseal unit

F21E.ai

C70SE ISO clamp Extended type

ISO76.1 ISO101.6

Backofdiaphragmseal unit

DirectMountHygienicDiaphragmSeal

Model Processconnectionstyle Processconnectionsize

F22E.ai

C30SW ISO clamp Flush type

ISO51 ISO76.1 ISO101.6

F23E.ai

C30SE ISO clamp Extended type

ISO51 ISO76.1 ISO101.6

Page 9: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

9<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Sep. 27, 2018-00

SPANANDRANGELIMITS

FlangeMountedDiaphragmSealSystem RemoteMountedSeal,DirectMountedSealwithRemoteSeal(Combinationtype),orCompensationCapillarytype

•EJXC80ADifferentialpressurediaphragmsealsystem

MeasurementSpan/Range kPa inH2O

(/D1)mbar(/D3)

mmH2O(/D4)

MSpan 2 to 100 8 to 400 20 to 1000 200 to 10000Range −100to100 −400to400 −1000to1000 −10000to10000

HSpan 10 to 500 40 to 2000 100 to 5000 0.1to5kgf/cm2

Range −500to500 −2000to2000 −5000to5000 −5to5kgf/cm2

VFlush type

Span 0.28 to 14 MPa 41 to 2000 psi 2.8to140bar 2.8to140kgf/cm2

Range −0.5to14MPa −71to2000psi −5to140bar −5to140kgf/cm2

Extended typeSpan 0.28 to 7 MPa 41 to 1000 psi 2.8to70bar 2.8to70kgf/cm2

Range −0.5to7MPa −71to1000psi −5to70bar −5to70kgf/cm2

•EJAC80EDifferentialpressurediaphragmsealsystem

MeasurementSpan/Range kPa inH2O

(/D1)mbar(/D3)

mmH2O(/D4)

MSpan 2.5 to 100 10 to 400 25 to 1000 250 to 10000Range −100to100 −400to400 −1000to1000 −10000to10000

HSpan 25 to 500 100 to 2000 250 to 5000 0.25to5kgf/cm2

Range −500to500 −2000to2000 −5000to5000 −5to5kgf/cm2

VFlush type

Span 0.28 to 14 MPa 41 to 2000 psi 2.8to140bar 2.8to140kgf/cm2

Range −0.5to14MPa −71to2000psi −5to140bar −5to140kgf/cm2

Extended typeSpan 0.28 to 7 MPa 41 to 1000 psi 2.8to70bar 2.8to70kgf/cm2

Range −0.5to7MPa −71to1000psi −5to70bar −5to70kgf/cm2

•EJXC80AGaugepressurediaphragmsealsystem

MeasurementSpan/Range MPa psi

(/D1)bar(/D3)

kg/cm2(/D4)

ASpan 0.035 to 3.5 5 to 500 0.35 to 35 0.35 to 35Range −0.1to3.5 −14.5to500 −1to35 −1to35

BFlush type

Span 0.16 to 16 23 to 2300 1.6 to 160 1.6 to 160Range −0.1to16 −14.5to2300 −1to160 −1to160

Extended typeSpan 0.16 to 7 23 to 1000 1.6 to 70 1.6 to 70Range −0.1to7 −14.5to1000 −1to70 −1to70

•EJAC80EGaugepressurediaphragmsealsystem

MeasurementSpan/Range MPa psi

(/D1)bar(/D3)

kg/cm2(/D4)

ASpan 0.06 to 3.5 8.6 to 500 0.6 to 35 0.6 to 35Range −0.1to3.5 −14.5to500 −1to35 −1to35

BFlush type

Span 0.46 to 16 67 to 2300 4.6 to 160 4.6 to 160Range −0.1to16 −14.5to2300 −1to160 −1to160

Extended typeSpan 0.46 to 7 67 to 1000 4.6 to 70 4.6 to 70Range −0.1to7 −14.5to1000 −1to70 −1to70

Page 10: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

10

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Sep. 27, 2018-00

•EJXC81AAbsolutepressurediaphragmsealsystem

MeasurementSpan/Range kPaabs psiabs

(/D1)mbarabs(/D3)

mmHgabs(/D4)

MSpan 2.7 to 130 0.8to38inHgabs 27 to 1300 20 to 970Range 0 to 130 0to38inHgabs 0 to 1300 0 to 970

ASpan 0.035to3.5MPaabs 5 to 500 0.35to35barabs 0.35to35kgf/cm2absRange 0to3.5MPaabs 0 to 500 0to35barabs 0to35kgf/cm2abs

BFlush type

Span 0.16to16MPaabs 23 to 2300 1.6to160barabs 1.6to160kgf/cm2absRange 0to16MPaabs 0 to 2300 0to160barabs 0to160kgf/cm2abs

Extended typeSpan 0.16to7MPaabs 23 to 1000 1.6to70barabs 1.6to70kgf/cm2absRange 0to7MPaabs 0 to 1000 0to70barabs 0to70kgf/cm2abs

•EJAC81EAbsolutepressurediaphragmsealsystem

MeasurementSpan/Range kPaabs psiabs

(/D1)mbarabs(/D3)

mmHgabs(/D4)

MSpan 3.4 to 130 1to38inHgabs 34 to 1300 26 to 970Range 0 to 130 0to38inHgabs 0 to 1300 0 to 970

ASpan 0.06to3.5MPaabs 8.7 to 500 0.6to35barabs 0.6to35kgf/cm2absRange 0to3.5MPaabs 0 to 500 0to35barabs 0to35kgf/cm2abs

BFlush type

Span 0.46to16MPaabs 67 to 2300 4.6to160barabs 4.6to160kgf/cm2absRange 0to16MPaabs 0 to 2300 0to160barabs 0to160kgf/cm2abs

Extended typeSpan 0.46to7MPaabs 67 to 1000 4.6to70barabs 4.6to70kgf/cm2absRange 0to7MPaabs 0 to 1000 0to70barabs 0to70kgf/cm2abs

Page 11: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

11<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Sep. 27, 2018-00

DirectMountedSeal•EJXC80ADifferentialpressurediaphragmsealsystem

MeasurementSpan/Range kPa inH2O

(/D1)mbar(/D3)

mmH2O(/D4)

MSpan 1 to 100 4 to 400 10 to 1000 100 to 10000Range −100to100 −400to400 −1000to1000 −10000to10000

HSpan 5 to 500 20 to 2000 50 to 5000 0.05to5kgf/cm2

Range −500to500 −2000to2000 −5000to5000 −5to5kgf/cm2

VFlush type

Span 0.14 to 14 MPa 20 to 2000 psi 1.4to140bar 1.4to140kgf/cm2

Range −0.5to14MPa −71to2000psi −5to140bar −5to140kgf/cm2

Extended typeSpan 0.14 to 7 MPa 20 to 1000 psi 1.4to70bar 1.4to70kgf/cm2

Range −0.5to7MPa −71to1000psi −5to70bar −5to70kgf/cm2

•EJAC80EDifferentialpressurediaphragmsealsystem

MeasurementSpan/Range kPa inH2O

(/D1)mbar(/D3)

mmH2O(/D4)

MSpan 1 to 100 4 to 400 10 to 1000 100 to 10000Range −100to100 −400to400 −1000to1000 −10000to10000

HSpan 5 to 500 20 to 2000 50 to 5000 0.05to5kgf/cm2

Range −500to500 −2000to2000 −5000to5000 −5to5kgf/cm2

VFlush type

Span 0.14 to 14 MPa 20 to 2000 psi 1.4to140bar 1.4to140kgf/cm2

Range −0.5to14MPa −71to2000psi −5to140bar −5to140kgf/cm2

Extended typeSpan 0.14 to 7 MPa 20 to 1000 psi 1.4to70bar 1.4to70kgf/cm2

Range −0.5to7MPa −71to1000psi −5to70bar −5to70kgf/cm2

•EJXC50AGaugepressurediaphragmsealsystem

MeasurementSpan/Range MPa psi

(/D1)bar(/D3)

kg/cm2(/D4)

ASpan 8 to 200 kPa 1.16 to 29 0.08 to 2 0.08 to 2Range −100to200kPa −14.5to29 −1to2 −1to2

BSpan 0.04 to 2 5.8 to 290 0.4 to 20 0.4 to 20Range −0.1to2 −14.5to290 −1to20 −1to20

CFlush type

Span 0.2 to 10 29 to 1450 2 to 100 2 to 100Range −0.1to10 −14.5to1450 −1to100 −1to100

Extended typeSpan 0.2 to 7 29 to 1000 2 to 70 2 to 70Range −0.1to7 −14.5to1000 −1to70 −1to70

•EJAC50EGaugepressurediaphragmsealsystem

MeasurementSpan/Range MPa psi

(/D1)bar(/D3)

kg/cm2(/D4)

ASpan 10 to 200 kPa 1.45 to 29 0.1 to 2 0.1 to 2Range −100to200kPa −14.5to29 −1to2 −1to2

BSpan 0.1 to 2 14.5 to 290 1 to 20 1 to 20Range −0.1to2 −14.5to290 −1to20 −1to20

CFlush type

Span 0.5 to 10 72.5 to 1450 5 to 100 5 to 100Range −0.1to10 −14.5to1450 −1to100 −1to100

Extended typeSpan 0.5 to 7 72.5 to 1000 5 to 70 5 to 70Range −0.1to7 −14.5to1000 −1to70 −1to70

Page 12: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

12

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Sep. 27, 2018-00

HygienicDiaphragmSealSystem RemoteMountedSeal,orDirectMountedSealwithRemoteSeal(Combinationtype)•EJXC80ADifferentialpressurediaphragmsealsystem

MeasurementSpan/Range kPa inH2O

(/D1)mbar(/D3)

mmH2O(/D4)

MSpan 2 to 100 8 to 400 20 to 1000 200 to 10000Range −100to100 −400to400 -1000 to 1000 -10000 to 10000

HSpan 10 to 500 40 to 2000 100 to 5000 0.1to5kg/cm2

Range −500to500 −2000to2000 -5000 to 5000 −5to5kg/cm2

VSpan 0.28 to 1 MPa 41 to 145 psi 2.8to10bar 2.8to10kg/cm2

Range −0.5to1MPa −71to145psi −5to10bar −5to10kg/cm2

•EJAC80EDifferentialpressurediaphragmsealsystem

MeasurementSpan/Range kPa inH2O

(/D1)mbar(/D3)

mmH2O(/D4)

MSpan 2.5 to 100 10 to 400 25 to 1000 250 to 10000Range −100to100 −400to400 -1000 to 1000 -10000 to 10000

HSpan 25 to 500 100 to 2000 250 to 5000 0.25to5kg/cm2

Range −500to500 −2000to2000 -5000 to 5000 −5to5kg/cm2

VSpan 0.28 to 1 MPa 41 to 145 psi 2.8to10bar 2.8to10kg/cm2

Range −0.5to1MPa −71to145psi −5to10bar −5to10kg/cm2

•EJXC80AGaugepressurediaphragmsealsystem

MeasurementSpan/Range MPa psi

(/D1)bar(/D3)

kg/cm2(/D4)

ASpan 0.035 to 1 5 to 145 0.35 to 10 0.35 to 10Range −0.1to1 −14.5to145 −1to10 −1to10

•EJAC80EGaugepressurediaphragmsealsystem

MeasurementSpan/Range MPa psi

(/D1)bar(/D3)

kg/cm2(/D4)

ASpan 0.06 to 1 8.6 to 145 0.6 to 10 0.6 to 10Range −0.1to1 −14.5to145 −1to10 −1to10

DirectMountedSeal•EJXC80ADifferentialpressurediaphragmsealsystem

MeasurementSpan/Range kPa inH2O

(/D1)mbar(/D3)

mmH2O(/D4)

MSpan 1 to 100 4 to 400 10 to 1000 100 to 10000Range −100to100 −400to400 -1000 to 1000 -10000 to 10000

HSpan 5 to 500 20 to 2000 50 to 5000 0.05to5kg/cm2

Range −500to500 −2000to2000 -5000 to 5000 −5to5kg/cm2

VSpan 0.14 to 1 MPa 20 to 145 psi 1.4to10bar 1.4to10kg/cm2

Range −0.5to1MPa −71to145psi −5to10bar −5to10kg/cm2

•EJAC80EDifferentialpressurediaphragmsealsystem

MeasurementSpan/Range kPa inH2O

(/D1)mbar(/D3)

mmH2O(/D4)

MSpan 1 to 100 4 to 400 10 to 1000 100 to 10000Range −100to100 −400to400 -1000 to 1000 -10000 to 10000

HSpan 5 to 500 20 to 2000 50 to 5000 0.05to5kg/cm2

Range −500to500 −2000to2000 -5000 to 5000 −5to5kg/cm2

VSpan 0.14 to 1 MPa 20 to 145 psi 1.4to10bar 1.4to10kg/cm2

Range −0.5to1MPa −71to145psi −5to10bar −5to10kg/cm2

Page 13: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

13<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Sep. 27, 2018-00

•EJXC50AGaugepressurediaphragmsealsystem

MeasurementSpan/Range MPa psi

(/D1)bar(/D3)

kg/cm2(/D4)

ASpan 8 to 200 kPa 1.16 to 29 0.08 to 2 0.08 to 2Range −100to200kPa −14.5to29 −1to2 −1to2

BSpan 0.04 to 1 5.8 to 145 0.4 to 10 0.4 to 10Range −0.1to1 −14.5to145 −1to10 −1to10

•EJAC50EGaugepressurediaphragmsealsystem

MeasurementSpan/Range MPa psi

(/D1)bar(/D3)

kg/cm2(/D4)

ASpan 10 to 200 kPa 1.45 to 29 0.1 to 2 0.1 to 2Range −100to200kPa −14.5to29 −1to2 −1to2

BSpan 0.1 to 1 14.5 to 145 1 to 10 1 to 10Range −0.1to1 −14.5to145 −1to10 −1to10

DigitalRemoteSensorDiaphragmSealSystem FlangeMounted•EJXC40ADigitalremotesensordiaphragmsealsystem

MeasurementSpan/Range MPa psi

(/D1)bar(/D3)

kg/cm2(/D4)

ASpan 2 to 200 kPa 0.3 to 29 0.02 to 2 0.02 to 2Range −200to200kPa −29to29 −2to2 −2to2

BSpan 0.01 to 2 1.5 to 290 0.1 to 20 0.1 to 20Range −2to2 −290to290 −20to20 −20to20

CFlush type

Span 0.05 to 10 7.3 to 1450 0.5 to 100 0.5 to 100Range −10to10 −1450to1450 −100to100 −100to100

Extended typeSpan 0.05 to 7 7.3 to 1000 0.5 to 70 0.5 to 70Range −7to7 −1000to1000 −70to70 −70to70

Hygienic•EJXC40ADigitalremotesensordiaphragmsealsystem

MeasurementSpan/Range MPa psi

(/D1)bar(/D3)

kg/cm2(/D4)

ASpan 2 to 200 kPa 0.3 to 29 0.02 to 2 0.02 to 2Range −200to200kPa −29to29 −2to2 −2to2

BSpan 0.01 to 1 1.5 to 145 0.1 to 10 0.1 to 10Range −1to1 −145to145 −10to10 −10to10

Page 14: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

14

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Nov. 20, 2019-00

Processtemperature,Ambienttemperature,andWorkingpressure

EJXC80A,EJAC80ERemoteMountedSeal,DirectMountedSealwithRemoteSeal(Combinationtype),orCompensationCapillarytypeDiaphragmSealSystem

Table1-1a. FlangeMounted

Code Processtemperature*1

Ambienttemperature*2 Workingpressure Specificgravity*3

Silicone oil (general use) A −10to315°C*4

(14to599°F)−10to60°C (14to140°F) 2.7kPaabs(0.38psiabs)

toflangeratingpressure*91.07

Silicone oil (general use) B −40to210°C*4

(−40to410°F)−30to60°C

(−22to140°F) 0.94

Silicone oil (low temperature use) F −70to100°C

(−94to212°F)−30to60°C

(−22to140°F)100kPaabs(atmosphericpressure)

toflangepressurerating 0.88

Fluorinated oil (oil-prohibiteduse) D −20to120°C

(−4to248°F)−10to60°C (14to140°F)

51kPaabs(7.4psiabs) toflangeratingpressure 1.90 to 1.92

Ethylene glycol (low temperature use) E −50to100°C

(−58to212°F)−40to60°C

(−40to140°F) 100kPaabs(atmosphericpressure) toflangepressurerating

1.09

Propylene glycol P −10to120°C (14to248°F)

−10to60°C (14to140°F) 1.04

Silicone oil*8 (high temp. and high vacuum use)

1 −10to250°C*4 (14to482°F)

−10to60°C*5 (14to140°F)

0.013kPaabs (0.0019psiabs)

toflangeratingpressure

1.07

Silicone oil*8 (high temp. and high vacuum use)

2 10to315°C*4 (50to599°F)

10to60°C*5 (50to140°F) 1.09

Silicone oil*8 (high vacuum use) 4 −10to100°C

(14to212°F)−10to60°C*5 (14to140°F) 1.07

Table1-1b. HygienicMounted

Code Processtemperature*1

Ambienttemperature*2 Workingpressure Specificgravity*3

Silicone oil (general use) B −10to120°C*6

(14to248°F)−10to60°C (14to140°F) 2.7kPaabs(0.38psiabs)to1MPaG 0.94

Silicone oil (general use) P −10to120°C*7

(14to248°F)−10to60°C (14to140°F)

100kPaabs(atmosphericpressure)to 1MPaG 1.04

Note: Thedifferentialpressuretransmittershouldbeinstalledatleast600mmbelowthehighpressure(HP)processconnection. However,thisvalue(600mm)maybeaffectedbyambienttemperature,operatingpressure,fillfluidormaterialofthe

wetted diaphragm. ContactYOKOGAWAwhenthetransmittercannotbeinstalledatleast600mmbelowtheHPprocessconnection

*1: Seefigure1a,1b,1cand1d‘WorkingPressureandProcessTemperature.’*2: Thisambienttemperatureisthetransmitterambienttemperature.*3: Approximatevaluesatatemperatureof25°C(77°F)*4: IncaseofdiaphragmmaterialcodeT(Tantalum),processtemperaturelimitisupto200°C(392°F).*5: Theupperambienttemperaturelimitis50°(122°F)inthefollowingcombinations.

Model ProcessconnectionsizecodeC80FW Flush type 2(2-inch)or8(11/2-inch)C80FE Extension type 3 (3-inch)

*6: Temperaturelimitofcleansingprocessisupto150°C(302°F)/max.60minutes*7: Temperaturelimitofcleansingprocessisupto150°C(302°F)/max.30minutes*8: Applicableforbothsideremotemountflangeddifferentialdiaphragmsealorgaugepressurediaphragmsealsystem.*9: Incaseofcompensationcapillarytype,seefigure1j‘Workingpressureandcapillarylength’.

Page 15: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

15<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Sep. 27, 2018-00

EJXC80A,EJAC80EDirectMountedDiaphragmSealSystem

Table1-2a. FlangeMounted

Code Processtemperature*1*2

Ambienttemperature*3*7 Workingpressure Specificgravity*4

Silicone oil (general use) A −10to315°C*5

(14to599°F)−10to85°C (14to185°F) 2.7kPaabs(0.38psiabs)

toflangeratingpressure

1.07

Silicone oil (general use) B −40to210°C*5

(−40to410°F)−40to85°C

(−40to185°F) 0.94

Silicone oil (low temperature use) F −70to100°C

(−94to212°F)−40to85°C

(−40to185°F)100kPaabs(atmosphericpressure)

toflangepressurerating 0.88

Fluorinated oil (oil-prohibiteduse) D −20to120°C*6

(−4to248°F)−20to80°C (−4to176°F)

51kPaabs(7.4psiabs) toflangeratingpressure 1.90 to 1.92

Ethylene glycol (low temperature use) E −50to100°C

(−58to212°F)−40to85°C

(−40to185°F) 100kPaabs(atmosphericpressure) toflangepressurerating

1.09

Propylene glycol P −10to120°C (14to248°F)

−10to85°C (14to185°F) 1.04

Table1-2b. HygienicMounted

Code Processtemperature*1

Ambienttemperature*2 Workingpressure Specificgravity*4

Silicone oil (general use) B −10to120°C*8

(14to248°F)−10to60°C (14to140°F)

2.7kPaabs(0.38psiabs) to 1MPaG 0.94

Propylene glycol P −10to120°C*9 (14to248°F)

−10to60°C (14to140°F)

100kPaabs(atmospheric pressure) to 1MPaG 1.04

*1: Seefigure1eand1f‘WorkingPressureandProcessTemperature.’*2: Indicateshighpressuresidevalue.Theprocesstemperaturelimitforlowpressuresideis–40to120°C(–40to248°F).*3: Thisambienttemperatureisthetransmitterambienttemperature.*4: Approximatevaluesatatemperatureof25°C(77°F)*5: IncaseofdiaphragmmaterialcodeT(Tantalum),processtemperaturelimitisupto200°C(392°F).*6: Theprocesstemperaturelimitforlowerpressuresideis–20to80°C(–4to176°F.)*7: Seefigure1gand1h‘AmbientTemperatureandProcessTemperature.’*8: Temperaturelimitofcleansingprocessisupto150°C(302°F)/max.60minutes*9: Temperaturelimitofcleansingprocessisupto150°C(302°F)/max.30minutes

Page 16: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

16

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Sep. 27, 2018-00

EJXC81A,EJAC81EAbsolutePressureDiaphragmSealSystem

Table2. FlangeMounted

Code Processtemperature*1

Ambienttemperature*2 Workingpressure Specificgravity*3

Silicone oil (general use) A −10to315°C*4

(14to599°F)−10to60°C (14to140°F) 2.7kPaabs(0.38psiabs)

toflangeratingpressure

1.07

Silicone oil (general use) B −40to210°C*4

(−40to410°F)−30to60°C (−22to140°F) 0.94

Silicone oil (high temp. and high vacuum use)

1 −10to250°C*4 (14to482°F)

−10to60°C*5 (14to140°F)

0.013kPaabs (0.0019psiabs)

toflangeratingpressure

1.07

Silicone oil (high temp. and high vacuum use)

2 10to315°C*4 (50to599°F)

10to60°C*5 (50to140°F) 1.09

Silicone oil (high vacuum use) 4 −10to100°C

(14to212°F)−10to60°C*5 (14to140°F) 1.07

Note: Thedifferentialpressuretransmittershouldbeinstalledatleast600mmbelowthehighpressure(HP)processconnection. However,thisvalue(600mm)maybeaffectedbyambienttemperature,operatingpressure,fillfluidormaterialofthe

wetted diaphragm. ContactYOKOGAWAwhenthetransmittercannotbeinstalledatleast600mmbelowtheHPprocessconnection

*1: Seefigure1a,1cand1d‘WorkingPressureandProcessTemperature.’*2: Thisambienttemperatureisthetransmitterambienttemperature.*3: Approximatevaluesatatemperatureof25°C(77°F)*4: IncaseofdiaphragmmaterialcodeT(Tantalum),processtemperaturelimitisupto200°C(392°F).*5: Theupperambienttemperaturelimitis50°(122°F)inthefollowingcombinations.

Model ProcessconnectionsizecodeC80FW Flush type 2(2-inch)or8(11/2-inch)C80FE Extension type 3 (3-inch)

EJXC50A,EJAC50EDirectMountedDiaphragmSealSystemEJXC40ADigitalRemoteSensorDiaphragmSealSystem

Table3-1a. FlangeMounted

Code Processtemperature*1

Ambienttemperature*2*5 Workingpressure Specificgravity*3

Silicone oil (general use) A −10to315°C*4

(14to599°F)−10to85°C (14to185°F) 2.7kPaabs(0.38psiabs)

toflangeratingpressure

1.07

Silicone oil (general use) B −40to210°C*4

(−40to410°F)−40to85°C

(−40to185°F) 0.94

Silicone oil (low temperature use) F −70to100°C

(−94to212°F)−40to85°C

(−40to185°F)100kPaabs(atmosphericpressure)

toflangepressurerating 0.88

Fluorinated oil (oil-prohibiteduse) D −20to120°C

(−4to248°F)−20to80°C (−4to176°F)

51kPaabs(7.4psiabs) toflangeratingpressure 1.90 to 1.92

Ethylene glycol (low temperature use) E −50to100°C

(−58to212°F)−40to85°C

(−40to185°F) 100kPaabs(atmosphericpressure) toflangepressurerating

1.09

Propylene glycol P −10to120°C (14to248°F)

−10to85°C (14to185°F) 1.04

Table3-2a. HygienicMounted

Code Processtemperature*1

Ambienttemperature*2 Workingpressure Specificgravity*3

Silicone oil (general use) B −10to120°C*6

(14to248°F)−10to60°C (14to140°F) 2.7kPaabs(0.38psiabs)to1MPaG 0.94

Propylene glycol P −10to120°C*7 (14to248°F)

−10to60°C (14to140°F)

100kPaabs(atmosphericpressure)to 1MPaG 1.04

*1: Seefigure1eand1f‘WorkingPressureandProcessTemperature.’*2: Thisambienttemperatureisthetransmitterambienttemperature.*3: Approximatevaluesatatemperatureof25°C(77°F)*4: IncaseofdiaphragmmaterialcodeT(Tantalum),processtemperaturelimitisupto200°C(392°F).*5: Seefigure1gand1h‘AmbientTemperatureandProcessTemperature.’*6: Temperaturelimitofcleansingprocessisupto150°C(302°F)/max.60minutes*7: Temperaturelimitofcleansingprocessisupto150°C(302°F)/max.30minutes

Page 17: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

17<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Sep. 27, 2018-00

*1: Forfillfluidcode2,thelowerambienttemperaturelimitis+10°Cforfillfluidcode2.*2: ForC80FWwhoseprocessconnectionsizeis2-inchor11/2-inch)orC80FEwhoseprocessconnectionsizeis3-inch,the

upperambienttemperaturelimitis+50°C.*3: ForC80FWwithprocessconnectionsize2-inchor11/2-inchorC80FEwithprocessconnectionsize3-inch,whenthediaphragmmaterial

codeis“S”andcapillarylengthis11morlonger,thelowerambienttemperaturelimitis-10°Candupperambienttemperaturelimitis+50°C.*4: ForC80FWwithprocessconnectionsize2-inchor11/2-inchorC80FEwithprocessconnectionsize3-inch,andthediaphragm

materialcodeotherthan“S”,thelowerambienttemperaturelimitis-15°Candupperambienttemperaturelimitis+60°C.

forEJXC80A,EJAC80E,EJXC81A,EJAC81ERemoteMountFlangedDiaphragmSealSystem

Process temperature for fill fluid code B

Process temperature for fill fluid code F

Process temperature for fill fluid code A

Flange max. working pressure

Atmospheric pressure

Transmitter ambient temperature range*3*4

Working pressurekPa abs

2.7

Temperature °C

100

0.1

1

10

-50-100 0 50 100 150 200 250 300 350

F24E.ai

Figure1a.WorkingPressureandProcessTemperature(Fillfluid:siliconeoilforgeneralandlowtemperatureuse)

Process temperature for fill fluid code E Process temperature

for fill fluid code DFlange max. working pressure

Transmitter ambient temperature range

Working pressurekPa abs

2.7

Temperature °C

100

0.1

1

10

51

-50-100 0 50 100 150 200 250 300 350

F25E.ai

Process temperature for fill fluid code P

Atmospheric pressure

Figure1b.WorkingPressureandProcessTemperature(Fillfluid:fluorinatedoilforoil-prohibiteduse,ethyleneglycolandpropyleneglycol)

Process temperature for fill fluid code 1

Process temperature for fill fluid code 2

Flange max. working pressure

Atmospheric pressure

Transmitter ambient temperature range*1*2

F26E.aiTemperature °C-50 0 50 100 150 200 250 300 350

Working pressurekPa abs

2.7

100

0.1

0.013

0.01

1

10

Figure1c.WorkingPressureandProcessTemperature(Fillfluid:siliconeoilforhightemp.andhighvacuumuse)

Process temperature for fill fluid code 4

Flange max. working pressure

Atmospheric pressure

F27E.aiTemperature °C-50 0 50 100 150 200 250 300 350

Working pressurekPa abs

2.7

100

0.1

0.013

0.01

1

10

Transmitter ambient temperature range*2

Figure1d.WorkingPressureandProcessTemperature(Fillfluid:siliconeoilforhighvacuumuse)

Page 18: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

18

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN June 1, 2017-00

forEJXC80A,EJAC80EDirectMountFlangedDiaphragmSealSystemEJXC50A,EJAC50EDirectMountFlangedDiaphragmSealSystemEJXC40ADigitalRemoteSensorFlangeMountedDiaphragmSealSystem

Process temperature for fill fluid code F

Process temperature for fill fluid code B Process temperature

for fill fluid code A

Working pressure kPa abs

2.7

100

0.1

1

10

-50 0 50 100 150 200 250 300 350-100Temperature °C

Flange max. working pressure

Transmitter ambient temperature range

F28E.ai

Figure1e.WorkingPressureandProcessTemperature(Fillfluid:siliconeoilforgeneralandlowtemperatureuse)

Process temperature for fill fluid code E

Process temperature for fill fluid code P

Process temperature for fill fluid code D

Flange max. working pressure

Transmitter ambient temperature range

Working pressure kPa abs

2.7

Temperature °C

100

0.1

1

10

-50 0 50 100 150 200 250 300 350

F29E.ai

-100

51

Figure1f.WorkingPressureandProcessTemperature(Fillfluid:siliconeoilforoil-prohibiteduse,ethyleneglycolandpropyleneglycol)

0 340-100 100 200 300

0

-20

-40

-60

-80

-100

100

80

60

40

20

Fill fluid code A

Fill fluid code FA

mbi

ent t

empe

ratu

re °

C

Process temperature °C

Fill fluid code B

F30E.ai

Figure1g.AmbientTemperatureandProcessTemperature(Fillfluid:siliconeoilforgeneralandlowtemperatureuse)

0 340-100 100 200 300

0

-20

-40

-60

-80

-100

100

80

60

40

20

Fill fluid code E

Fill fluid code P

F31E.aiProcess temperature °C

Am

bien

t tem

pera

ture

°C

Fill fluid code D

Figure1h.AmbientTemperatureandProcessTemperature(Fillfluid:siliconeoilforoil-prohibiteduse,ethyleneglycolandpropyleneglycol)

Page 19: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

19<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Nov. 20, 2019-00

ForEJXC80A,EJAC80ERemoteMountHygienicDiaphragmSealSystemEJXC80A,EJAC80EDirectMountHygienicDiaphragmSealSystemEJXC50A,EJAC50EDirectMountHygienicDiaphragmSealSystemEJXC40ADigitalRemoteSensorHygienicDiaphragmSealSystem

F32E.ai

Process temperature for fill fluid code B

Clamp max working pressure

Atmospheric pressure

Transmitter ambient temperature range

Working pressure kPa abs

Temperature °C

Process temperature for fill fluid code P

2.7

100

1

10

-50 0 50 100 150

Figure1i. WorkingPressureandProcessTemperature(Fillfluid:siliconeoil)

50

Difference in height of diaphragm seal between high pressure side and low pressure side (m)

13.31 2 3 4 5 6 7 8

F33E.ai

Flange max.working pressure

kPa abs

100 Atmosphericpressure

Applicable range

Workingpressure

Figure1j. WorkingpressureandcapillarylengthNote: Approximate value at normal temperature when

using silicone oil (Code A or B).

ResponseTime(): RemoteMountedDiaphragmSealSystem*1

Capsule

Differentialpressuretransmitter

Gaugepressuretransmitter

Absolutepressuretransmitter

M,H,V A,B M,A,B

Response time *1 200 ms(approximate value at normal temperature)

DirectMountedDiaphragmSealSystem

Capsule

Differentialpressuretransmitter

Gaugepressuretransmitter

M,H,V A,B,C

Response time *2 120 ms(approximate value at normal temperature)

DigitalRemoteSensoredDiaphragmSealSystem

CapsuleGaugepressuretransmitter

A,B,C

Response time *3 250 ms(approximate value at normal temperature)

*1: WhenfillfluidcodeB,andcapillarylengthof10m.*2: Whensoftwaredampingissettozeroand

includingdeadtimeof45ms(nominal)*3: Whensoftwaredampingissettozeroand

includingdeadtimeof90ms(nominal) Providedthattheamplifiersoftwaredampingandthe

staticpressuredampingofbothmasterandslavesensors are set to 0.00s. Dead time is included.

FUNCTIONALSPECIFICATIONSDampingTimeConstant(1storder)Amplifierdampingtimeconstantisadjustablefrom0.00to100.00sbysoftwareandaddedtoresponsetime.Note: ForBRAINprotocoltypefordirectmounted

diaphragmsealsystem,whenamplifiersoftwaredamping is set to less than 0.5 s, communication mayoccasionallybeunavailableduringtheoperation, especially while output changes dynamically.Thedefaultsettingofdampingensuresstablecommunication.

CapillaryFillFluidDensityCompensation(forRemotemonteddiaphragmsealsystem,andOutputsignalcodeD,EandJ)Compensationofthezeroshiftbytheambienttemperatureeffectonthecapillarytube.

EURoHSDirectiveEN 50581

Page 20: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

20

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Sep. 27, 2018-00

NORMALOPERATINGCONDITION(Optionalfeaturesorapprovalcodesmayaffectlimits.)

AmbientandProcessTemperatureLimitsSeetable1,2,3andfollowingtable

Model AmbienttemperaturelimitswithLCDDisplaytype

Remote mount −30to60°C(−22to140°F)Direct mount −30to80°C(−22to176°F)

WorkingPressureLimitsSeetable1,2,3Foratmosphericpressureorbelow,seefigure1ato1g

PHYSICALSPECIFICATIONSForthedetailsoftransmitterpart,pleaserefertoeachtransmitter’sGeneralSpecificationssheet.Wetted Parts Materials

WettedPartsMaterialsDiaphragm and other wetted parts;Referto“MODELANDSUFFIXCODES.”

EJXC80A,EJAC80E,EJXC81A,EJAC81ERemoteMountDiaphragmSealSystem

Transmitter section

F34E.ai

Pressure detector section

•Transmitter:2.8kg(6.2lb) Add1.5kg(3.3lb)forAmplifierhousingcode2. (EJX110A, EJX430A, EJA110E, EJA430E without integralindicatorandmountingbracket.)

•Flushtype(C80FW):6.7kg(14.8lb) (3-inchANSIClass150flange,capillarylength5m)

•Extendedtype(C80FE):9.5kg(21lb) (4-inchANSIClass150flange,extensionlength(X2)=100 mm, capillary length 5 m)

•Hygienicmountedflushtype(C70SW):2.2kg(4.9lb)(ISO101.6 Clamp, capillary length 5 m)

•Hygienicmountedextendedtype(C70SE):4.3kg(9.5lb)(SO101.6Clamp,extensionlength(X2)=52mm,

capillary length 5 m)

Note) aboveindicatedweightisforahighpressuresideor a low pressure side

EJXC80A,EJAC80EDirectMountDiaphragmSealSystem

Transmitter section

Pressure detector section

F35E.ai

•Transmitter:2.8kg(6.2lb) Add1.5kg(3.3lb)forAmplifierhousingcode2. (EJX110A, EJX430A, EJA110E, EJA430E without integralindicatorandmountingbracket.)

•Flushtype(C20FW):.5.5kg(12.2lb) (3-inchANSIClass150flange)

•Extendedtype(C80FE):10kg(22.1lb) (4-inchANSIClass150flange,extensionlength(X2)=100 mm)

•Hygienicflushtype(C30SW):1.3kg(2.9lb)(ISO101.6 Clamp)

•Hygienicextendedtype(C30SE):4.4kg(9.7lb)(ISO101.6 Clamp, extension length (X2)=52 mm)

EJXC50A,EJAC50EDirectMountDiaphragmSealSystemEJXC40ADigitalRemoteSensorDiaphragmSealSystem

Pressure detector section

Transmitter section

F36E.ai

•Transmitter:1.3kg(2.9lb) (EJX530A, EJA530E without integral indicator and mountingbracket.)

•Flangemountedflushtype(C20FW):5.5kg(12.2lb) (3-inchANSIClass150flange)

•Flangemountedextensiontype(C20FE):10kg(22.1lb) (4-inchANSIClass150flange,extensionlength(X2)=100 mm

•Hygienicflushtype(C30SW):1.3kg(2.9lb) (ISO101.6 Clamp)

•Hygienicextendedtype(C30SE):4.4kg(9.7lb) (ISO101.6 Clamp, extension length (X2)=52 mm)Note) IncaseofDRS,aboveindicatedweightisfora

high pressure side (master) or a low pressure side (slave) transmitter

Page 21: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

21<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Sep. 27, 2018-00

MODELANDSUFFIXCODESThemodelcodesofDiaphragmSealSystemconsistofadiaphragmsealsystem,atransmitterpartandadiaphragmseal(s)part.Variouskindsofproductscanberealizedbycombiningatransmitterwithdiaphragmseal(s)Thissheetdescribesthecodesofthediaphragmsealsystemandthediaphragmsealpart.Forthecodesofthetransmitterpart,pleaserefertotheGeneralSpecificationsofeachapplicabletransmitter.

Pressure detector section

F37E.ai

Transmitter section

with flushing connection ring

Transmitter section

Pressure detector section

Differential Pressure Diaphragm Seal System (High and low pressure remote seals)Diaphragm Seal System

Differential pressure transmitterRemote Mounted Diaphragm Seal (High pressure side)Remote Mounted Diaphragm Seal (Low pressure side)Flushing connection ring (High pressure side)*1

Flushing connection ring (Low pressure side)*1

Differential Pressure Diaphragm Seal System (Single pressure remote seals)Diaphragm Seal System

Differential pressure transmitterRemote Mounted Diaphragm Seal (High pressure side)Flushing connection ring (High pressure side)*1

Gauge/Absolute Diaphragm Seal SystemDiaphragm Seal System

Gauge/Absolute pressure transmitterRemote Mounted Diaphragm Seal (High pressure side)Flushing connection ring (High pressure side)*1

Direct Mounted Diaphragm Seal SystemDiaphragm Seal System

Gauge pressure transmitterDirect Mounted Diaphragm SealFlushing connection ring*1

Digital Remote Sensored Diaphragm Seal SystemDiaphragm Seal System

Gauge pressure transmitter (High pressure side (Master))Gauge pressure transmitter (Low pressure side (Slave))Direct Mounted Diaphragm Seal (High pressure side)Direct Mounted Diaphragm Seal (Low pressure side)Flushing connection ring (High pressure side)*1

Flushing connection ring (Low pressure side)*1

*1: Specify when a flushing connection ring is required.

Pressure detector section

Transmitter section

Page 22: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

22

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Sep. 27, 2018-00

Transmitter Model GSNo.Differentialpressuretransmitter EJX110A GS 01C25B01-01EN

EJA110E GS 01C31B01-01EN

Gauge pressure transmitter EJX430A GS 01C25E01-01EN

EJA430E GS 01C31E01-01EN

EJX530A GS 01C25F01-01EN

EJA530E GS 01C31F01-01EN

Absolutepressuretransmitter EJX310A GS 01C25D01-01EN

EJA310E GS 01C31D01-01EN

Digital remote sensor EJXC40A GS 01C25W05-01EN

Page 23: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

23<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Sep. 27, 2018-00

INDEX

1. DiaphragmSealSystem.................................................................................................... 251.1 DiaphragmSealSystem............................................................................................................................25

1.2 AbsolutePressureDiaphragmSealSystem...........................................................................................26

1.3 DirectMountedDiaphragmSealSystem................................................................................................26

1.4 DigitalRemoteSensoredDiaphragmSealSystem................................................................................27

2. RemoteMountFlangedDiaphragmSeal........................................................................ 282.1 3-inch(80mm)/2-inch(50mm)/Raisedface(RF),FlushtypeForgeneraluse,Capillary

ConnectionStyle:Sideofdiaphragmsealunit......................................................................................28

2.2 3-inch(80mm)/2-inch(50mm)Raisedface(RF),Flushtypeforgeneraluse,CapillaryConnectionStyle:Backofdiaphragmsealunit.....................................................................................31

2.3 3-inch(80mm)/2-inch(50mm)Ringtypejoint(RJ),Flushtypeforgeneraluse,CapillaryConnectionStyle:Sideofdiaphragmsealunit.......................................................................................33

2.4 3-inch(80mm)/2-inch(50mm)Raisedface(RF),FlushtypeHighvacuum/Hightemp.andhighvacuumuseCapillaryConnectionStyle:Sideofdiaphragmsealunit......................................35

2.5 11/2-inch(40mm)Raisedface(RF),Flushtypeforgeneraluse,CapillaryConnectionStyle:Sideofdiaphragmsealunit......................................................................................................................37

2.6 11/2-inch(40mm)Raisedface(RF),FlushtypeHighvacuum/Hightemp.andhighvacuumuseCapillaryConnectionStyle:Sideofdiaphragmsealunit..............................................................39

3. RemoteMountFlangedDiaphragmSeal(Extendedtype)............................................ 413.1 4-inch(100mm)/3-inch(80mm)Raisedface(RF),Extendedtypeforgeneraluse,Capillary

ConnectionStyle:Backofdiaphragmsealunit.....................................................................................41

3.2 4-inch(100mm)/3-inch(80mm)Raisedface(RF)ExtendedtypeHighvacuum/Hightemp.andhighvacuumuseCapillaryConnectionStyle:Backofdiaphragmsealunit..............................44

4. RemoteMountFlangedDiaphragmSeal(InnerDiaphragmtype)................................................474.1 1/2-inch(15mm)/3/4-inch(20mm)1-inch(25mm)Adapterconnectiontype,Raisedface(RF)

forgeneraluse,CapillaryConnectionStyle:Backofdiaphragmsealunit........................................47

4.2 1/2-inch(15mm)/3/4-inch(20mm)/1-inch(25mm)Adapterconnectiontype,Ringtypejoint(RJ)forgeneraluse,CapillaryConnectionStyle:Backofdiaphragmsealunit.......................................50

4.3 1/2-inch(15mm)/3/4-inch(20mm)/1-inch(25mm)Flangeconnectiontype,Raisedface(RF)forgeneraluse,CapillaryConnectionStyle:Backofdiaphragmsealunit...............................................52

4.4 1/2-inch(15mm)/3/4-inch(20mm)/1-inch(25mm)Flangeconnectiontype,Ringtypejoint(RJ)forgeneraluse,CapillaryConnectionStyle:Backofdiaphragmsealunit........................................54

4.5 1/2-inch(15mm)/3/4-inch(20mm)/1-inch(25mm)Adapterconnectiontype,Raisedface(RF)Highvacuum/Hightemp.andhighvacuumuseCapillaryConnectionStyle:Backofdiaphragmsealunit.......................................................................................................................................................56

4.6 1/2-inch(15mm)/3/4-inch(20mm)/1-inch(25mm)Adapterconnectiontype,Ringtypejoint(RJ)Highvacuum/Hightemp.andhighvacuumuseCapillaryConnectionStyle:Backofdiaphragmsealunit.......................................................................................................................................................58

4.7 1/2-inch(15mm)/3/4-inch(20mm)/1-inch(25mm)Flangeconnectiontype,Raisedface(RF)Highvacuum/Hightemp.andhighvacuumuseCapillaryConnectionStyle:Backofdiaphragmsealunit.......................................................................................................................................................60

Page 24: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

24

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Sep. 27, 2018-00

4.8 1/2-inch(15mm)/3/4-inch(20mm)/1-inch(25mm)Flangeconnectiontype,Ringtypejoint(RJ)Highvacuum/Hightemp.andhighvacuumuseCapillaryConnectionStyle:Backofdiaphragmsealunit.......................................................................................................................................................62

5. DirectMountFlangedDiaphragmSeal(Flushtype)...................................................... 645.1 3-inch(80mm)/2-inch(50mm)Raisedface(RF).................................................................................64

5.2 11/2-inch(40mm)Raisedface(RF)........................................................................................................66

6. DirectMountFlangedDiaphragmSeal(Extendedtype)............................................... 686.1 4-inch(100mm)/3-inch(80mm)Raisedface(RF)...............................................................................68

7. RemotemountHygienicDiaphragmSeal...................................................................... 717.1 ISO101.6/ISO76.1ClampFlushtype......................................................................................................71

7.2 ISO51ClampFlushtype.............................................................................................................................73

7.3 ISO101.6/ISO76.1Clamptype.................................................................................................................75

8. DirectMountHygienicDiaphragmSeal.......................................................................... 778.1 ISO101.6/ISO76.1ClampFlushtype......................................................................................................77

8.2 ISO51ClampFlushtype............................................................................................................................79

8.3 ISO101.6/ISO76.1ClampExtendedtype...............................................................................................81

8.4 ISO51ClampExtendedtype.....................................................................................................................83

9. FlushingConnectionRing................................................................................................ 85

10. TankSpud........................................................................................................................... 87

11. OPTIONALSPECIFICATIONS........................................................................................... 88

12. PERFORMANCESPECIFICATIONS.................................................................................. 9312.1 EJXC80ADiaphragmSealSystem...........................................................................................................93

12.2 EJXC80ADirectMountedDiaphragmSealSystem...............................................................................94

12.3 EJXC50APerformancespecifications.....................................................................................................94

12.4 EJXC40A Performancespecifications.....................................................................................................94

12.5 EJAC80EDiaphragmSealSystemPerformancespecifications..........................................................95

12.6 EJAC80EDirectMountedDiaphragmSealSystemPerformancespecifications...............................96

12.7 EJAC50EPerformancespecifications.....................................................................................................96

13. Capillarylengthlimitation................................................................................................. 97

ApplicableProducts................................................................................................................ 128

Page 25: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

25<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Sep. 27, 2018-00

1. DiaphragmSealSystem1.1 DiaphragmSealSystem

F38E.ai

Model SuffixCodes DescriptionEJXC80AEJAC80E

.................................................................... Diaphragm Seal System*2

Measurement type -D........................................................... DifferentialPressure-G.......................................................... Gauge Pressure

High Pressure Side Style 8........................................................ Remotemountflangeddiaphragmseal7........................................................ Remote mount hygienic diaphragm seal2........................................................ Directmountflangeddiaphragmseal3........................................................ Direct mount hygienic diaphragm seal0........................................................ None

LowPressureSideStyle 8................................................... Remotemountflangeddiaphragmseal7................................................... Remote mount hygienic diaphragm seal0................................................... None

Measurement Span (capsule) .............................................. Selectfrommeasurementspan(capsule)codesofthetransmitter.

(Differentialpressure:M,H,orVGaugepressure:AorB)Process Connection High-side 1.......................................... WithRc1/4femaleprocessconnector

2.......................................... WithRc1/2femaleprocessconnector3.......................................... With1/4NPTfemaleprocessconnector4.......................................... With1/2NPTfemaleprocessconnectorW......................................... With Flush type sealE.......................................... With Extended type sealA.......................................... With inner diaphragm seal (adapter connection)D.......................................... Withinnerdiaphragmseal(flangeconnection)N.......................................... None

Wetted parts High-sideHigh-side Process connector

C..................................... Process connector material (ASTM CF-8M*1)

High-side Diaphragm seal ..................................... Selectfromdiaphragmmaterialcodesofdiaphragmseal.

(Diaphragm material codes: S, V, H, J, T, U, M, or K)without process connector, and Diaphragm seal

N..................................... None

ProcessConnectionLow-side 1................................ WithRc1/4femaleprocessconnector2................................ WithRc1/2femaleprocessconnector3................................ With1/4NPTfemaleprocessconnector4................................ With1/2NPTfemaleprocessconnectorW............................... With Flush type sealE................................ With Extended type sealA................................ With inner diaphragm seal (adapter connection)D................................ Withinnerdiaphragmseal(flangeconnection)N................................ None

WettedpartsLow-sideLow-side Process connector

C........................... Process connector material (ASTM CF-8M*1)

Low-side Diaphragm seal ........................... Selectfromdiaphragmmaterialcodesofdiaphragmseal.

(Diaphragm material codes: S, V, H, J, T, U, M, or K)without process connector, and Diaphragm seal

N........................... None *IncaseofGaugepressuretransmitter,Itmustbeselected (Low-side:opentoatmosphere)

Fillfluid ....................... Refertotable1Accessory High-side -J................. Bolts:ASTM-B7carbonsteelforProcessconnector

-G................ Bolts:316LSSTforProcessconnector-C................. Bolts:ASTMgrade660SSTforProcessconnector-1................. With C10FR Flushing Connection Ring-N................. None

AccessoryLow-side J............. Bolts:ASTM-B7carbonsteelforProcessconnectorG............. Bolts:316LSSTforProcessconnectorC............. Bolts:ASTMgrade660SSTforProcessconnector1............. With C10FR Flushing Connection RingN............. None

*1: Castversionof316SST.EquivalenttoSCS14A.*2: Seesubsection“ApplicableProducts”.

Page 26: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

26

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Sep. 27, 2018-00

1.2 AbsolutePressureDiaphragmSealSystem

F39E.ai

Model SuffixCodes DescriptionEJXC81AEJAC81E

............................................................. Absolutepressurediaphragmsealsystem*1

Measurement type -A..................................................... AbsolutePressureStyle 8.................................................. Remotesealflangeddiaphragmseal-------- 0.............................................. NoneMeasurement Span (capsule) .......................................... Selectfrommeasurementspan(capsule)codesofthetransmitter.

(M, A or B)Process Connection W..................................... With Flush type seal

E...................................... With Extended type sealA...................................... With inner diaphragm seal (adapter connection)D...................................... Withinnerdiaphragmseal(flangeconnection)

Wetted parts .................................. Selectfromdiaphragmmaterialcodesofdiaphragmseal.(Diaphragm material codes: S, H, or T)

-------- N.............................. None-------- N.......................... NoneFillfluid ...................... RefertoTable2Accessory -1................. WithC10FRflushingconnectionring

-N................. None-------- N.............. None

*1: Seesubsection“ApplicableProducts”.

1.3 DirectMountedDiaphragmSealSystem

F40E.ai

Model SuffixCodes DescriptionEJXC50AEJAC50E

............................................................. Direct mounted diaphragm seal system*1

Measurement type -G.................................................... Gauge PressureStyle 5.................................................. Directmountflangeddiaphragmseal

6.................................................. Direct mount hygienic diaphragm seal-------- 0.............................................. NoneMeasurement Span (capsule) .......................................... Selectfrommeasurementspan(capsule)codesofthetransmitter.

(A, B or C)Process Connection W..................................... With Flush type seal

E...................................... With Extended type sealWetted parts .................................. Selectfromdiaphragmmaterialcodesofdiaphragmseal.

(Diaphragm material codes: S, V, H, J, T, U, M, or K)-------- N.............................. None-------- N.......................... NoneFillfluid ...................... RefertoTable3Accessory -1................. WithC10FRflushingconnectionring

-N................. None-------- N.............. None

*1: Seesubsection“ApplicableProducts”.

Page 27: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

27<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Sep. 27, 2018-00

1.4 DigitalRemoteSensoredDiaphragmSealSystem

F41E.ai

Model SuffixCodes DescriptionEJXC40A ............................................................. Digital remote sensored diaphragm seal system*4

Measurement type -D..................................................... DifferentialPressureMaster Style (High pressure side)

5.................................................. Directmountflangeddiaphragmseal6.................................................. Direct mount Hygienic diaphragm sealS.................................................. Screw mount*1

Slave Style (Lowpressureside)

5.............................................. Directmountflangeddiaphragmseal6.............................................. Direct mount Hygienic diaphragm sealS.............................................. Screw mount*1

Digital Remote Sensor R.......................................... Digital Remote SensorProcess Connection forMaster

W..................................... WithFlushtypeflangedsealE...................................... WithExtendedtypeflangedsealT...................................... With Screw monted

WettedpartsforMasterMaster (High-side) Diaphragm seal .................................. Selectfromdiaphragmmaterialcodesofdiaphragmseal.

(Diaphragm material codes: S, V, H, J, T, U, M, or K)Master (High-side) Screw mounted .................................. SelectfromGS01C25W05-01EN(EJXC40A)

(Wettedpartsmaterialcodes:L,orA)ProcessConnectionforSlave W............................. WithFlushtypeflangedseal

E.............................. WithExtendedtypeflangedsealT.............................. With Screw monted

WettedpartsforSlaveSlave(Low-side) Diaphragm seal .......................... Selectfromdiaphragmmaterialcodesofdiaphragmseal.

(Diaphragm material codes: S, V, H, J, T, U, M, or K)Slave(Low-side) Screw mounted .......................... SelectfromGS01C25W05-01EN(EJXC40A)

(Wettedpartsmaterialcodes:L,orA)Fill Fluid*2 ...................... Refertotable3AccessoryforMaster -1................. WithC10FRflushingconnectionring

-N................. NoneAccessoryforSlave 1.............. WithC10FRflushingconnectionring

N.............. None

*1: Applicablewhenscrewmountisspecifiedwitheithermasterorslave.*2: Itmustbeselectedfillfluidfromdiaphragmseal.Whenselectingscrewmountedeithermasterorslave,limitsof

temperatureisfollowingtable.andrefertoGS01C25W05-01EN(EJXC40A)fordetailspecifications.

Processtemperature AmbienttemperatureSilicone −40to120°C(−40to248°F) −40to85°C(−40to185°F)*3

Fluorinated oil (optional) −40to120°C(−40to248°F) −20to80°C(−4to176°F)

*3: −30to80°C(−22to176°F)withLCDdisplay*4: Seesubsection“ApplicableProducts”.

Optioncode/EC(DRScable)alwaysmustbespecified.

Page 28: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

28

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Sep. 27, 2018-00

2. RemoteMountFlangedDiaphragmSeal2.1 3-inch(80mm)/2-inch(50mm)/Raisedface(RF),Flushtype

Forgeneraluse,CapillaryConnectionStyle:Sideofdiaphragmsealunit

F42E.ai

Model SuffixCodes DescriptionC80FW ............................................................................... Remote Mount Flanged Diaphragm Seal (Flush type)Seal system location

-H........................................................................... forhighpressureside-L........................................................................... forlowpressureside

Sealfillfluid ......................................................................... Refertotable2b.Transmitter connection type

-S.....................................................................-C.....................................................................

forgeneraluseforcompensatingcapillarytype*11

Capillary length*2

1.................................................................... 1 m 6......................... 6 m B......................... 11 m2.................................................................... 2 m 7......................... 7 m C......................... 12 m3.................................................................... 3 m 8......................... 8 m D......................... 13 m4.................................................................... 4 m 9......................... 9 m E......................... 14 m5.................................................................... 5 m A......................... 10 m F......................... 15 m

Capillary inside diameter

2................................................................. Capillary I.D. 2.03 mm1................................................................. Capillary I.D. 1.3 mm*12

Capillary Style [Usage] [Sheath style]S.............................................................. forgeneraluse with PVC sheathV.............................................................. without PVC sheathW............................................................. with PVC sheath red-colorR.............................................................. forprocessoperating

temperature correction*3with PVC sheath

T.............................................................. with PVC sheath red-colorCapillaryTubeConnection

S............................................................ forgeneraluseT............................................................ With corrosion protection

Process Connection size*4

-3........................................................ 3-inch (80 mm)-2........................................................ 2-inch (50 mm)

Sealing Face F...................................................... Raisedface(RF)Gasketcontactsurface

1....................................................Serration (ANSI B16.5)(forANSIflangewithsealingfacematerialSonly)

2.................................................... Flat (no serration)Diaphragm material S................................................. 316LSST M............ Monel

H................................................. Hastelloy C-276*8 K............. NickelT................................................. Tantalum*11 V............. 316LSSTU................................................. Titanium (Thickness: 0.0055 inch (0.14 mm))

J............. Hastelloy C-276*8*9

(Thickness: 0.006 inch (0.15 mm))Sealingfacematerial S.............................................. 316LSST M............ Monel

H.............................................. Hastelloy C-276*8 K............. NickelT.............................................. TantalumU.............................................. Titanium

Diaphragm diameter 9............................................ Diaphragm O.D: 3.54-inch (90 mm)*9

6............................................ Diaphragm O.D: 2.4-inch (61 mm)Diaphragm option A......................................... Gold-plated diaphragm*6

P......................................... With platinum plate*7

N......................................... None-------- N...................................... Always NCapillary connection A................................... SideofdiaphragmsealunitFlangesize*4 -3................................ 3-inch (80 mm)

-2................................ 2-inch (50 mm)Flange standards J.............................. JIS

A.............................. ANSIP.............................. JPID.............................. DIN

Page 29: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

29<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Sep. 27, 2018-00

Flange pressure rating 1........................... class150 A.............. 10K H.............. PN10/162........................... class300 B.............. 20K K.............. PN25/404........................... class600 C.............. 30K L.............. PN645........................... class900 *9 D.............. 40K6........................... class1500 *9 E.............. 63K

Flange type S......................... forgeneraluseFlange material A...................... JIS S25C C................... 316 SST*5

B...................... 304 SST*10 S................... 316LSST*5

Extended outside diameter -0.................. NoneExtended length 0................. None-------- N.............. Always N

Table2a. DiaphragmmaterialandSealingfacematerial

Wettedpartsmaterial*1 [Diaphragm material] [Sealingfacematerial]SS........................ [S]316LSST [S]316LSSTHH....................... [H] Hastelloy C-276*8# [H] Hastelloy C-276*8#TT........................ [T] Tantalum [T] TantalumUU....................... [U] Titanium [U] TitaniumMM...................... [M] Monel [M] MonelKK....................... [K] Nickel [K] NickelVS........................ [V]316L

(Thickness: 0.0055 inch (0.14 mm))[S]316LSST

JH........................ [J] Hastelloy C-276*8# (Thickness: 0.006 inch (0.15 mm))

[H] Hastelloy C-276*8#

*1: Usersmustconsiderthecharacteristicsofselectedwettedpartsmaterialandtheinfluenceofprocessfluids.Theuseofinappropriatematerialscanresultintheleakageofcorrosiveprocessfluidsandcauseinjurytopersonneland/ordamagetoplantfacilities.Itisalsopossiblethatthediaphragmitselfcanbedamagedandthatmaterialfromthebrokendiaphragmandthefillfluidcancontaminatetheuser’sprocessfluids.

Beverycarefulwithhighlycorrosiveprocessfluidssuchashydrochloricacid,sulfuricacid,hydrogensulfide,sodiumhypochlorite,andhightemperaturesteam(150°C[302°F]orabove).ContactYokogawafordetailedinformationofthewetted parts material.

*2: Refertosection12forlimitationofcapillarylength.*3: Applicableforoptioncode/R(Operatingtemperaturecorrection).Incaseof“withoutPVCsheath”,mustbeselectcodeV.*4: NotapplicabletodifferentsizebetweenProcessconnectionsizeandFlangesize.*5: Forgedversionofthematerialmaybeused.*6: ApplicableforDiaphragmmaterialcodeSandH. Insideofisolatingdiaphragms(fillfluidside)aregoldplated,effectiveforhydrogenpermeation.*7: ApplicableforDiaphragmmaterialcodeT.*8: Hastelloy C-276 or N10276.*9: Notapplicableforprocessconnectionsizecode2.*10: NotapplicableforflangestandardscodeD.*11: Incaseofcompensationcapillarytype,mustbeselectcode“-C”onsealsystemlocationcode“-L”.*12: Applicableforprocessconnectionsizecode“2”withcapillarylengthmorethan6m.

The‘#’marksindicatetheconstructionmaterialsconformtoNACEmaterialrecommendationsperMR0175(2003).Pleaserefertolateststandardsfordetails.

Page 30: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

30

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Sep. 27, 2018-00

Table2b. ProcesstemperatureandAmbienttemperature

Code Processtemperature*13

Ambienttemperature*16 Workingpressure Specific

gravity*17

Silicone oil*14 (general use) A −10to315°C

(14to599°F)−10to60°C (14to140°F) 2.7kPaabs(0.38psiabs)

toflangeratingpressure

1.07

Silicone oil*14 (general use) B −30to210°C

(−22to410°F)−30to60°C

(−22to140°F) 0.94

Silicone oil (low temperature use) F −70to100°C

(−94to212°F)−30to60°C

(−22to140°F)100kPaabs(atmosphericpressure)

toflangepressurerating 0.88

Fluorinated oil*15 (oil-prohibiteduse) D −20to120°C

(−4to248°F)−10to60°C (14to140°F)

51kPaabs(7.4psiabs) toflangeratingpressure 1.90 to 1.92

Ethylene glycol (low temperature use) E −50to100°C

(−58to212°F)−40to60°C

(−40to140°F) 100kPaabs(atmosphericpressure) toflangepressurerating

1.09

Propylene glycol P −10to120°C (14to248°F)

−10to60°C (14to140°F) 1.04

Note: Thedifferentialpressuretransmittershouldbeinstalledatleast600mmbelowthehighpressure(HP)processconnection. However,thisvalue(600mm)maybeaffectedbyambienttemperature,operatingpressure,fillfluidormaterialofthe

wetted diaphragm. ContactYOKOGAWAwhenthetransmittercannotbeinstalledatleast600mmbelowtheHPprocessconnection.

*13: Seefigure1a,1b‘WorkingPressureandProcessTemperature.’*14: IncaseofdiaphragmmaterialcodeT(Tantalum),processtemperaturelimitisupto200°C(392°F).*15: EvenincasewherefillfluidcodeD(fluorinatedoil)isselected,ifdegreasecleansingtreatmentorbothdegreasecleansing

anddehydratingtreatmentforthewettedpartsisrequired,specifyoptioncodeK31orK35.*16: Thisambienttemperatureisthetransmitterambienttemperature.*17: Approximatevaluesatatemperatureof25°C(77°F)

Page 31: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

31<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Sep. 27, 2018-00

2.2 3-inch(80mm)/2-inch(50mm)Raisedface(RF),Flushtypeforgeneraluse,CapillaryConnectionStyle:Backofdiaphragmsealunit

F43E.ai

Model SuffixCodes DescriptionC80FW ............................................................................... Remote Mount Flanged Diaphragm Seal (Flush type)Seal system location

-H........................................................................... forhighpressureside-L........................................................................... forlowpressureside

Sealfillfluid ......................................................................... Refertotable2d.Transmitter connection type -S..................................................................... forgeneraluse

forcompensatingcapillarytype*12

Capillary length*2

1.................................................................... 1 m 6..................... 6 m B........................ 11 m2.................................................................... 2 m 7..................... 7 m C........................ 12 m3.................................................................... 3 m 8..................... 8 m D........................ 13 m4.................................................................... 4 m 9..................... 9 m E........................ 14 m5.................................................................... 5 m A..................... 10 m F........................ 15 m

Capillary inside diameter

2.................................................................1.................................................................

Capillary I.D. 2.03 mmCapillary I.D. 1.3 mm*13

Capillary Style [Usage] [Sheath style]S.............................................................. forgeneraluse with PVC sheathV.............................................................. without PVC sheathW............................................................. with PVC sheath red-colorR.............................................................. forprocessoperating

temperature correction*3with PVC sheath

T.............................................................. with PVC sheath red-colorCapillaryTubeConnection

S............................................................ forgeneraluse(Length:200mm)C............................................................ Shorttype(Length:100mm)

Process Connection size*4

-3........................................................ 3-inch (80 mm)-2........................................................ 2-inch (50 mm)

Sealing Face F...................................................... Raisedface(RF)Gasketcontactsurface 1.................................................... Serration (ANSI B16.5)

(forANSIflangewithsealingfacematerialSonly)2.................................................... Flat (no serration)

Diaphragm material S................................................. 316LSSTSealingfacematerial S.............................................. 316LSST*6

Diaphragm diameter 9............................................ Diaphragm O.D: 3.54-inch (90 mm)*11

6............................................ Diaphragm O.D: 2.4-inch (61 mm)Diaphragm option A......................................... Gold-plated diaphragm*6

N......................................... None-------- N...................................... Always NCapillary connection B................................... BackofdiaphragmsealunitFlangesize*4 -3................................ 3-inch (80 mm)

-2................................ 2-inch (50 mm)Flange standards J.............................. JIS

A.............................. ANSIP.............................. JPI

Flange pressure rating 1........................... class150 A............ 10K E............ 63K2........................... class300 B............ 20K4........................... class600 D............ 40K

Flange type S......................... forgeneraluseFlange material B...................... 304 SST*5

C...................... 316 SST*5

Extended outside diameter -0.................. NoneExtended length 0................. None-------- N.............. Always N

Page 32: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

32

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Sep. 27, 2018-00

Table2c. DiaphragmmaterialandSealingfacematerial

Wettedpartsmaterial*1 [Diaphragm material] [Sealingfacematerial]

SS........................ [S]316LSST [S]316LSST

*1: Usersmustconsiderthecharacteristicsofselectedwettedpartsmaterialandtheinfluenceofprocessfluids.Theuseofinappropriatematerialscanresultintheleakageofcorrosiveprocessfluidsandcauseinjurytopersonneland/ordamagetoplantfacilities.Itisalsopossiblethatthediaphragmitselfcanbedamagedandthatmaterialfromthebrokendiaphragmandthefillfluidcancontaminatetheuser’sprocessfluids.

Beverycarefulwithhighlycorrosiveprocessfluidssuchashydrochloricacid,sulfuricacid,hydrogensulfide,sodiumhypochlorite,andhightemperaturesteam(150°C[302°F]orabove).ContactYokogawafordetailedinformationofthewetted parts material.

*2: Refertosection12forlimitationofcapillarylength.*3: Applicableforoptionalcode/R(Operatingtemperaturecorrection).Incaseof“withoutPVCsheath”,mustbeselectcodeV.*4: NotapplicabletodifferentsizebetweenProcessconnectionsizeandFlangesize.*5: Forgedversionofthematerialmaybeused.*6: Insideofisolatingdiaphragms(fillfluidside)aregoldplated,effectiveforhydrogenpermeation.

Table2d. ProcesstemperatureandAmbienttemperature

Code Processtemperature*7

Ambienttemperature*9 Workingpressure Specific

gravity*10

Silicone oil (general use) A −10to315°C

(14to599°F)−10to60°C (14to140°F) 2.7kPaabs(0.38psiabs)

toflangeratingpressure

1.07

Silicone oil (general use) B −30to210°C

(−22to410°F)−30to60°C

(−22to140°F) 0.94

Silicone oil (low temperature use) F −70to100°C

(−94to212°F)−30to60°C

(−22to140°F)100kPaabs(atmosphericpressure)

toflangepressurerating 0.88

Fluorinated oil*8 (oil-prohibiteduse) D −20to120°C

(−4to248°F)−10to60°C (14to140°F)

51kPaabs(7.4psiabs) toflangeratingpressure 1.90 to 1.92

Ethylene glycol (low temperature use) E −50to100°C

(−58to212°F)−40to60°C

(−40to140°F) 100kPaabs(atmosphericpressure) toflangepressurerating

1.09

Propylene glycol P −10to120°C (14to248°F)

−10to60°C (14to140°F) 1.04

Note: Thedifferentialpressuretransmittershouldbeinstalledatleast600mmbelowthehighpressure(HP)processconnection. However,thisvalue(600mm)maybeaffectedbyambienttemperature,operatingpressure,fillfluidormaterialofthe

wetted diaphragm. ContactYOKOGAWAwhenthetransmittercannotbeinstalledatleast600mmbelowtheHPprocessconnection.

*7: Seefigure1a,1b‘WorkingPressureandProcessTemperature.’*8: EvenincasewherefillfluidcodeD(fluorinatedoil)isselected,ifdegreasecleansingtreatmentorbothdegreasecleansing

anddehydratingtreatmentforthewettedpartsisrequired,specifyoptioncodeK31orK35.*9: Thisambienttemperatureisthetransmitterambienttemperature.*10: Approximatevaluesatatemperatureof25°C(77°F)*11: Notapplicableforprocessconnectionsizecode2*12: Incaseofcompensationcapillarytype,mustbeselectcode“-C”onsealsystemlocationcode“-L”.*13: Applicableforprocessconnectionsizecode“2”withcapillarylengthmorethan6m.

Page 33: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

33<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Sep. 27, 2018-00

2.3 3-inch(80mm)/2-inch(50mm)Ringtypejoint(RJ),Flushtypeforgeneraluse,CapillaryConnectionStyle:Sideofdiaphragmsealunit

F44E.ai

Model SuffixCodes DescriptionC80FW ............................................................................... Remote Mount Flanged Diaphragm Seal (Flush type)Seal system location

-H........................................................................... forhighpressureside-L........................................................................... forlowpressureside

Sealfillfluid ......................................................................... Refertotable2f.Transmitter connection type -S..................................................................... forgeneraluse

Capillary length*2

1.................................................................... 1 m 6..................... 6 m B..................... 11 m2.................................................................... 2 m 7..................... 7 m C..................... 12 m3.................................................................... 3 m 8..................... 8 m D..................... 13 m4.................................................................... 4 m 9..................... 9 m E..................... 14 m5.................................................................... 5 m A..................... 10 m F..................... 15 m

Capillary inside diameter

2.................................................................1.................................................................

Capillary I.D. 2.03 mmCapillary I.D. 1.3 mm*13

Capillary Style [Usage] [Sheath style]S.............................................................. forgeneraluse with PVC sheathV.............................................................. without PVC sheathW............................................................. with PVC sheath red-colorR.............................................................. forprocessoperating

temperature correction*3with PVC sheath

T.............................................................. with PVC sheath red-colorCapillaryTubeConnection S............................................................ forgeneraluse

Process Connection size*4

-3........................................................ 3-inch (80 mm)-2........................................................ 2-inch (50 mm)

Sealing Face J...................................................... Ring type joint (RJ)Gasketcontactsurface 2.................................................... Flat (no serration)Diaphragm material S................................................. 316LSST

H................................................. Hastelloy C-276*7

Sealingfacematerial S.............................................. 316LSSTDiaphragm diameter 9............................................ Diaphragm O.D: 3.54-inch (90 mm)*12

6............................................ Diaphragm O.D: 2.4-inch (61 mm)Diaphragm option A......................................... Gold-plated diaphragm*6

N......................................... None-------- N...................................... Always NCapillary connection A................................... SideofdiaphragmsealunitFlangesize*4 -3................................ 3-inch (80 mm)

-2................................ 2-inch (50 mm)Flange standards A.............................. ANSI

P.............................. JPIFlange pressure rating 2........................... class300

4........................... class6005........................... class9006........................... class1500

Flange type J......................... forRingtypejoint(RJ)Flange material A...................... JIS S25C

B...................... 304 SST*5

C...................... 316 SST*5

S...................... 316LSST*5

Extended outside diameter -0.................. NoneExtended length 0................. None-------- N.............. Always N

Page 34: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

34

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Sep. 27, 2018-00

Table2e. DiaphragmmaterialandSealingfacematerial

Wettedpartsmaterial*1 [Diaphragm material] [Sealingfacematerial]SS........................ [S]316LSST [S]316LSSTHS....................... [H] Hastelloy C-276*7# [S]316LSST

*1: Usersmustconsiderthecharacteristicsofselectedwettedpartsmaterialandtheinfluenceofprocessfluids.Theuseofinappropriatematerialscanresultintheleakageofcorrosiveprocessfluidsandcauseinjurytopersonneland/ordamagetoplantfacilities.Itisalsopossiblethatthediaphragmitselfcanbedamagedandthatmaterialfromthebrokendiaphragmandthefillfluidcancontaminatetheuser’sprocessfluids.

Beverycarefulwithhighlycorrosiveprocessfluidssuchashydrochloricacid,sulfuricacid,hydrogensulfide,sodiumhypochlorite,andhightemperaturesteam(150°C[302°F]orabove).ContactYokogawafordetailedinformationofthewetted parts material.

*2: Refertosection12forlimitationofcapillarylength.*3: Applicableforoptioncode/R(Operatingtemperaturecorrection).Incaseof“withoutPVCsheath”,mustbeselectcodeV.*4: NotapplicabletodifferentsizebetweenProcessconnectionsizeandFlangesize.*5: Forgedversionofthematerialmaybeused.*6: Insideofisolatingdiaphragms(fillfluidside)aregoldplated,effectiveforhydrogenpermeation.*7: Hastelloy C-276 or N10276.The‘#’marksindicatetheconstructionmaterialsconformtoNACEmaterialrecommendationsperMR0175(2003).Pleaserefertolateststandardsfordetails.

Table2f. ProcesstemperatureandAmbienttemperature

Code Processtemperature*8

Ambienttemperature*10 Workingpressure Specific

gravity*11

Silicone oil (general use) A −10to315°C

(14to599°F)−10to60°C (14to140°F) 2.7kPaabs(0.38psiabs)

toflangeratingpressure

1.07

Silicone oil (general use) B −30to210°C

(−22to410°F)−30to60°C

(−22to140°F) 0.94

Silicone oil (low temperature use) F −70to100°C

(−94to212°F)−30to60°C

(−22to140°F)100kPaabs(atmosphericpressure)

toflangepressurerating 0.88

Fluorinated oil*9 (oil-prohibiteduse) D −20to120°C

(−4to248°F)−10to60°C (14to140°F)

51kPaabs(7.4psiabs) toflangeratingpressure 1.90 to 1.92

Ethylene glycol (low temperature use) E −50to100°C

(−58to212°F)−40to60°C

(−40to140°F) 100kPaabs(atmosphericpressure) toflangepressurerating

1.09

Propylene glycol P −10to120°C (14to248°F)

−10to60°C (14to140°F) 1.04

Note: Thedifferentialpressuretransmittershouldbeinstalledatleast600mmbelowthehighpressure(HP)processconnection. However,thisvalue(600mm)maybeaffectedbyambienttemperature,operatingpressure,fillfluidormaterialofthe

wetted diaphragm. ContactYOKOGAWAwhenthetransmittercannotbeinstalledatleast600mmbelowtheHPprocessconnection.

*8: Seefigure1a,1b‘WorkingPressureandProcessTemperature.’*9: EvenincasewherefillfluidcodeD(fluorinatedoil)isselected,ifdegreasecleansingtreatmentorbothdegreasecleansing

anddehydratingtreatmentforthewettedpartsisrequired,specifyoptioncodeK31orK35.*10: Thisambienttemperatureisthetransmitterambienttemperature.*11: Approximatevaluesatatemperatureof25°C(77°F)*12: Notapplicableforprocessconnectionsizecode2*13: Applicableforprocessconnectionsizecode“2”withcapillarylengthmorethan6m

Page 35: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

35<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Sep. 27, 2018-00

2.4 3-inch(80mm)/2-inch(50mm)Raisedface(RF),FlushtypeHighvacuum/Hightemp.andhighvacuumuseCapillaryConnectionStyle:Sideofdiaphragmsealunit

F45E.ai

Model SuffixCodes DescriptionC80FW ............................................................................... Remote Mount Flanged Diaphragm Seal (Flush type)Seal system location

-H........................................................................... forhighpressureside-L........................................................................... forlowpressureside

Sealfillfluid ......................................................................... Refertotable2h.Transmitter connection type -S..................................................................... forgeneraluse

Capillary length*2

1.................................................................... 1 m 6..................... 6 m2.................................................................... 2 m 7..................... 7 m3.................................................................... 3 m 8..................... 8 m4.................................................................... 4 m 9..................... 9 m5.................................................................... 5 m A..................... 10 m

Capillary inside diameter 2................................................................. Capillary I.D. 2.03 mm

Capillary Style [Usage] [Sheath style]1.............................................................. High temp. and

high vacuum usewith PVC sheath

2.............................................................. without PVC sheath3.............................................................. with PVC sheath red-color5.............................................................. High vacuum use with PVC sheath6.............................................................. without PVC sheath7.............................................................. with PVC sheath red-color

CapillaryTubeConnection

S............................................................ forgeneraluseT............................................................ With corrosion protection

Process Connection size*3

-3........................................................ 3-inch (80 mm)-2........................................................ 2-inch (50 mm)

Sealing Face F...................................................... Raisedface(RF)Gasketcontactsurface 1.................................................... Serration (ANSI B16.5)

(forANSIflangewithsealingfacematerialSonly)2.................................................... Flat (no serration)

Diaphragm material S................................................. 316LSSTH................................................. Hastelloy C-276*7

T................................................. Tantalum*6

Sealingfacematerial S.............................................. 316LSSTH.............................................. Hastelloy C-276*7

T.............................................. TantalumDiaphragm diameter 9............................................ Diaphragm O.D: 3.54-inch (90 mm)*14

6............................................ Diaphragm O.D: 2.4-inch (61 mm)Diaphragm option A......................................... Gold-plated diaphragm*5

N......................................... None-------- N...................................... Always NCapillary connection A................................... SideofdiaphragmsealunitFlangesize*3 -3................................ 3-inch (80 mm)

-2................................ 2-inch (50 mm)Flange standards J.............................. JIS

A.............................. ANSIP.............................. JPID.............................. DIN

Page 36: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

36

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Sep. 27, 2018-00

Flange pressure rating 1........................... class150 A........ 10K H........ PN10/162........................... class300 B........ 20K K........ PN25/404........................... class600 C........ 30K L........ PN645........................... class900 *8 D........ 40K6........................... class1500 *8 E........ 63K

Flange type S......................... forgeneraluseFlange material A...................... JIS S25C

B...................... 304 SST*4

C...................... 316 SST*4

S...................... 316LSST*4*15

Extended outside diameter -0.................. NoneExtended length 0................. None-------- N.............. Always N

Table2g. DiaphragmmaterialandSealingfacematerial

Wettedpartsmaterial*1 [Diaphragm material] [Sealingfacematerial]SS........................ [S]316LSST [S]316LSSTHH....................... [H] Hastelloy C-276*7# [H] Hastelloy C-276*7#TT........................ [T] Tantalum [T] Tantalum

*1: Usersmustconsiderthecharacteristicsofselectedwettedpartsmaterialandtheinfluenceofprocessfluids.Theuseofinappropriatematerialscanresultintheleakageofcorrosiveprocessfluidsandcauseinjurytopersonneland/ordamagetoplantfacilities.Itisalsopossiblethatthediaphragmitselfcanbedamagedandthatmaterialfromthebrokendiaphragmandthefillfluidcancontaminatetheuser’sprocessfluids.

Beverycarefulwithhighlycorrosiveprocessfluidssuchashydrochloricacid,sulfuricacid,hydrogensulfide,sodiumhypochlorite,andhightemperaturesteam(150°C[302°F]orabove).ContactYokogawafordetailedinformationofthewetted parts material.

*2: Refertosection12forlimitationofcapillarylength.*3: NotapplicabletodifferentsizebetweenProcessconnectionsizeandFlangesize.*4: Forgedversionofthematerialmaybeused.*5: ApplicableforDiaphragmmaterialcodeSandH. Insideofisolatingdiaphragms(fillfluidside)aregoldplated,effectiveforhydrogenpermeation.*6: Notapplicableforsealfillfluidcode2.*7: Hastelloy C-276 or N10276.*8: Notapplicableforprocessconnectionsizecode2.The‘#’marksindicatetheconstructionmaterialsconformtoNACEmaterialrecommendationsperMR0175(2003).Pleaserefertolateststandardsfordetails.

Table2h. ProcesstemperatureandAmbienttemperature

Code Processtemperature*9

Ambienttemperature*11 Workingpressure Specific

gravity*13

Silicone oil*10 (high temp. and high vacuum use)

1 −10to250°C (14to482°F)

−10to60°C*12 (14to140°F)

0.013kPaabs (0.0019psiabs)

toflangeratingpressure

1.07

Silicone oil (high temp. and high vacuum use)

2 10to315°C (50to599°F)

10to60°C*12 (50to140°F) 1.09

Silicone oil (high vacuum use) 4 −10to100°C

(14to212°F)−10to60°C*12 (14to140°F) 1.07

Note: Thedifferentialpressuretransmittershouldbeinstalledatleast600mmbelowthehighpressure(HP)processconnection. However,thisvalue(600mm)maybeaffectedbyambienttemperature,operatingpressure,fillfluidormaterialofthe

wetted diaphragm. ContactYOKOGAWAwhenthetransmittercannotbeinstalledatleast600mmbelowtheHPprocessconnection.

*9: Seefigure1a,1b‘WorkingPressureandProcessTemperature.’*10: IncaseofdiaphragmmaterialcodeT(Tantalum),processtemperaturelimitisupto200°C(392°F).*11: Thisambienttemperatureisthetransmitterambienttemperature.*12: Incaseofprocessconnectionsizecode2,ambienttemperaturelimitisupto50°C(122°F).*13: Approximatevaluesatatemperatureof25°C(77°F)*14: Notapplicableforprocessconnectionsizecode2.*15: NotapplicableforflangestandardscodeD.

Page 37: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

37<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Sep. 27, 2018-00

2.5 11/2-inch(40mm)Raisedface(RF),Flushtypeforgeneraluse,CapillaryConnectionStyle:Sideofdiaphragmsealunit

F46E.ai

Model SuffixCodes DescriptionC80FW ............................................................................... Remote Mount Flanged Diaphragm Seal (Flush type)Seal system location

-H........................................................................... forhighpressureside-L........................................................................... forlowpressureside

Sealfillfluid ......................................................................... Refertotable2j.Transmitter connection type

-S.....................................................................-C.....................................................................

forgeneraluseforcompensatingcapillarytype*12

Capillary length*2

1.................................................................... 1 m 6..................... 6 m B........................ 11 m2.................................................................... 2 m 7..................... 7 m C........................ 12 m3.................................................................... 3 m 8..................... 8 m D........................ 13 m4.................................................................... 4 m 9..................... 9 m E........................ 14 m5.................................................................... 5 m A..................... 10 m F........................ 15 m

Capillary inside diameter

2.................................................................1.................................................................

Capillary I.D. 2.03 mmCapillary I.D. 1.3 mm*13

Capillary Style [Usage] [Sheath style]S.............................................................. forgeneraluse with PVC sheathV.............................................................. without PVC sheathW............................................................. with PVC sheath red-colorR.............................................................. forprocessoperating

temperature correction*3with PVC sheath

T.............................................................. with PVC sheath red-colorCapillaryTubeConnection S............................................................ forgeneraluse

ProcessConnectionsize -8........................................................ 40A(11/2B)Sealing Face F...................................................... Raisedface(RF)Gasketcontactsurface 2.................................................... Flat (no serration)Diaphragm material S................................................. 316LSST

H................................................. Hastelloy C-276*6

Sealingfacematerial S.............................................. 316LSSTH.............................................. Hastelloy C-276*6

Diaphragm diameter 6............................................ Diaphragm O.D: 2.4-inch (61 mm)Diaphragm option A......................................... Gold-plated diaphragm*5

N......................................... None-------- N...................................... Always NCapillary connection A................................... SideofdiaphragmsealunitFlangesize -8................................ 40A(11/2B)Flange standards J.............................. JIS

A.............................. ANSIP.............................. JPI

Flange pressure rating 1........................... class150 A............ 10K D............ 40K2........................... class300 B............ 20K E............ 63K4........................... class600 C............ 30K

Flange type S......................... forgeneraluseFlange material A...................... JIS S25C

B...................... 304 SST*4

C...................... 316 SST*4

S...................... 316LSST*4

Extended outside diameter -0.................. NoneExtended length 0................. None-------- N.............. Always N

Note) 40A(11/2B)isareducertype.C10FR(Flushingconnectionring)isalwaysnecessarytobespecifiedwiththissize.

Page 38: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

38

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Sep. 27, 2018-00

Table2i. DiaphragmmaterialandSealingfacematerial

Wettedpartsmaterial*1 [Diaphragm material] [Sealingfacematerial]SS........................ [S]316LSST [S]316LSSTHH....................... [H] Hastelloy C-276*6# [H] Hastelloy C-276*6#

*1: Usersmustconsiderthecharacteristicsofselectedwettedpartsmaterialandtheinfluenceofprocessfluids.Theuseofinappropriatematerialscanresultintheleakageofcorrosiveprocessfluidsandcauseinjurytopersonneland/ordamagetoplantfacilities.Itisalsopossiblethatthediaphragmitselfcanbedamagedandthatmaterialfromthebrokendiaphragmandthefillfluidcancontaminatetheuser’sprocessfluids.

Beverycarefulwithhighlycorrosiveprocessfluidssuchashydrochloricacid,sulfuricacid,hydrogensulfide,sodiumhypochlorite,andhightemperaturesteam(150°C[302°F]orabove).ContactYokogawafordetailedinformationofthewetted parts material.

*2: Refertosection12forlimitationofcapillarylength.*3: Applicableforoptioncode/R(Operatingtemperaturecorrection).Incaseof“withoutPVCsheath”,mustbeselectcodeV.*4: Forgedversionofthematerialmaybeused.*5: Insideofisolatingdiaphragms(fillfluidside)aregoldplated,effectiveforhydrogenpermeation.*6: Hastelloy C-276 or N10276.The‘#’marksindicatetheconstructionmaterialsconformtoNACEmaterialrecommendationsperMR0175(2003).Pleaserefertolateststandardsfordetails.

Table2j. ProcesstemperatureandAmbienttemperature

Code Processtemperature*7

Ambienttemperature*9 Workingpressure Specific

gravity*10

Silicone oil*11 (general use) A −10to315°C

(14to599°F)−10to60°C (14to140°F) 2.7kPaabs(0.38psiabs)

toflangeratingpressure

1.07

Silicone oil (general use) B −30to210°C

(−22to410°F)−30to60°C

(−22to140°F) 0.94

Silicone oil (low temperature use) F −70to100°C

(−94to212°F)−30to60°C

(−22to140°F)100kPaabs(atmosphericpressure)

toflangepressurerating 0.88

Fluorinated oil*8 (oil-prohibiteduse) D −20to120°C

(−4to248°F)−10to60°C (14to140°F)

51kPaabs(7.4psiabs) toflangeratingpressure 1.90 to 1.92

Ethylene glycol (low temperature use) E −50to100°C

(−58to212°F)−40to60°C

(−40to140°F) 100kPaabs(atmosphericpressure) toflangepressurerating

1.09

Propylene glycol P −10to120°C (14to248°F)

−10to60°C (14to140°F) 1.04

Note: Thedifferentialpressuretransmittershouldbeinstalledatleast600mmbelowthehighpressure(HP)processconnection. However,thisvalue(600mm)maybeaffectedbyambienttemperature,operatingpressure,fillfluidormaterialofthe

wetted diaphragm. ContactYOKOGAWAwhenthetransmittercannotbeinstalledatleast600mmbelowtheHPprocessconnection.

*7: Seefigure1a,1b‘WorkingPressureandProcessTemperature.’*8: EvenincasewherefillfluidcodeD(fluorinatedoil)isselected,ifdegreasecleansingtreatmentorbothdegreasecleansing

anddehydratingtreatmentforthewettedpartsisrequired,specifyoptioncodeK31orK35.*9: Thisambienttemperatureisthetransmitterambienttemperature.*10: Approximatevaluesatatemperatureof25°C(77°F)*11: Fortheprocesswheretheprocesstemperatureexceeds250°C,specifygasketusagecode–HofC10FRflushing

connection ring.*12: Incaseofcompensationcapillarytype,mustbeselectcode“-C”onsealsystemlocationcode“-L”.*13: Applicableforcapillarylengthmorethan6m.

Page 39: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

39<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Nov. 7, 2016-00

2.6 11/2-inch(40mm)Raisedface(RF),FlushtypeHighvacuum/Hightemp.andhighvacuumuseCapillaryConnectionStyle:Sideofdiaphragmsealunit

F47E.ai

Model SuffixCodes DescriptionC80FW ............................................................................... Remote Mount Flanged Diaphragm Seal (Flush type)Seal system location

-H........................................................................... forhighpressureside-L........................................................................... forlowpressureside

Sealfillfluid ......................................................................... Refertotable2l.Transmitter connection type -S..................................................................... forgeneraluse

Capillary length*2

1.................................................................... 1 m 6..................... 6 m2.................................................................... 2 m 7..................... 7 m3.................................................................... 3 m 8..................... 8 m4.................................................................... 4 m 9..................... 9 m5.................................................................... 5 m A..................... 10 m

Capillary inside diameter 2................................................................. Capillary I.D. 2.03 mm

Capillary Style [Usage] [Sheath style]1.............................................................. High temp. and

high vacuum usewith PVC sheath

2.............................................................. without PVC sheath3.............................................................. with PVC sheath red-color5.............................................................. High vacuum use with PVC sheath6.............................................................. without PVC sheath7.............................................................. with PVC sheath red-color

CapillaryTubeConnection S............................................................ forgeneraluse

ProcessConnectionsize -8........................................................ 40A(11/2B)Sealing Face F...................................................... Raisedface(RF)Gasketcontactsurface 2.................................................... Flat (no serration)Diaphragm material S................................................. 316LSST

H................................................. Hastelloy C-276*5

Sealingfacematerial S.............................................. 316LSSTH.............................................. Hastelloy C-276*5

Diaphragm diameter 6............................................ Diaphragm O.D: 2.4-inch (61 mm)Diaphragm option A......................................... Gold-plated diaphragm*4

N......................................... None-------- N...................................... Always NCapillary connection A................................... SideofdiaphragmsealunitFlangesize -8................................ 40A(11/2B)Flange standards J.............................. JIS

A.............................. ANSIP.............................. JPI

Flange pressure rating 1........................... class150 A............ 10K D............ 40K2........................... class300 B............ 20K E............ 63K4........................... class600 C............ 30K

Flange type S......................... forgeneraluseFlange material A...................... JIS S25C

B...................... 304 SST*3

C...................... 316 SST*3

S...................... 316LSST*3

Extended outside diameter -0.................. NoneExtended length 0................. None-------- N.............. Always N

Note) 40A(11/2B)isareducertype.C10FR(Flushingconnectionring)isalwaysnecessarytobespecifiedwiththissize.

Page 40: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

40

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Sep. 27, 2018-00

Table2k. DiaphragmmaterialandSealingfacematerial

Wettedpartsmaterial*1 [Diaphragm material] [Sealingfacematerial]SS........................ [S]316LSST [S]316LSSTHH....................... [H] Hastelloy C-276*5# [H] Hastelloy C-276*5#

*1: Usersmustconsiderthecharacteristicsofselectedwettedpartsmaterialandtheinfluenceofprocessfluids.Theuseofinappropriatematerialscanresultintheleakageofcorrosiveprocessfluidsandcauseinjurytopersonneland/ordamagetoplantfacilities.Itisalsopossiblethatthediaphragmitselfcanbedamagedandthatmaterialfromthebrokendiaphragmandthefillfluidcancontaminatetheuser’sprocessfluids.

Beverycarefulwithhighlycorrosiveprocessfluidssuchashydrochloricacid,sulfuricacid,hydrogensulfide,sodiumhypochlorite,andhightemperaturesteam(150°C[302°F]orabove).ContactYokogawafordetailedinformationofthewetted parts material.

*2: Refertosection12forlimitationofcapillarylength.*3: Forgedversionofthematerialmaybeused.*4: Insideofisolatingdiaphragms(fillfluidside)aregoldplated,effectiveforhydrogenpermeation.*5: Hastelloy C-276 or N10276.The‘#’marksindicatetheconstructionmaterialsconformtoNACEmaterialrecommendationsperMR0175(2003).Pleaserefertolateststandardsfordetails.

Table2l. ProcesstemperatureandAmbienttemperature

Code Processtemperature*6

Ambienttemperature*7 Workingpressure Specific

gravity*8

Silicone oil (high temp. and high vacuum use)

1 −10to250°C (14to482°F)

−10to50°C (14to122°F) 0.013kPaabs

(0.0019psiabs) toflangeratingpressure

1.07

Silicone oil (high vacuum use) 4 −10to100°C

(14to212°F)−10to50°C (14to122°F) 1.07

Note: Thedifferentialpressuretransmittershouldbeinstalledatleast600mmbelowthehighpressure(HP)processconnection. However,thisvalue(600mm)maybeaffectedbyambienttemperature,operatingpressure,fillfluidormaterialofthe

wetted diaphragm. ContactYOKOGAWAwhenthetransmittercannotbeinstalledatleast600mmbelowtheHPprocessconnection.

*6: Seefigure1c,1d‘WorkingPressureandProcessTemperature.’*7: Thisambienttemperatureisthetransmitterambienttemperature.*8: Approximatevaluesatatemperatureof25°C(77°F)

Page 41: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

41<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Sep. 27, 2018-00

3. RemoteMountFlangedDiaphragmSeal(Extendedtype)3.1 4-inch(100mm)/3-inch(80mm)Raisedface(RF),Extendedtype

forgeneraluse,CapillaryConnectionStyle:Backofdiaphragmsealunit

F48E.ai

Model SuffixCodes DescriptionC80FE ............................................................................... Remote Mount Flanged Diaphragm Seal (Extended type)Seal system location

-H........................................................................... forhighpressureside-L........................................................................... forlowpressureside

Sealfillfluid ......................................................................... Refertotable3b.Transmitter connection type

-S.....................................................................-C.....................................................................

forgeneraluseforcompensatingcapillarytype*12

Capillary length*2*10

1.................................................................... 1 m 6..................... 6 m B..................... 11 m2.................................................................... 2 m 7..................... 7 m C..................... 12 m3.................................................................... 3 m 8..................... 8 m D..................... 13 m4.................................................................... 4 m 9..................... 9 m E..................... 14 m5.................................................................... 5 m A..................... 10 m F..................... 15 m

Capillary inside diameter

2.................................................................1.................................................................

Capillary I.D. 2.03 mmCapillary I.D. 1.3 mm*13

Capillary Style [Usage] [Sheath style]S.............................................................. forgeneraluse with PVC sheathV.............................................................. without PVC sheathW............................................................. with PVC sheath red-colorR.............................................................. forprocessoperating

temperature correction*3with PVC sheath

T.............................................................. with PVC sheath red-colorCapillaryTubeConnection S............................................................ forgeneraluse

Process Connection size*4

-4........................................................ 4-inch (100 mm)-3........................................................ 3-inch (80 mm)

Sealing Face F...................................................... Raisedface(RF)Gasketcontactsurface 1.................................................... Serration (ANSI B16.5)

(forANSIflangewithsealingfacematerialCandS)2.................................................... Flat (no serration)

Diaphragm material S................................................. 316LSST V........ 316LSSTH................................................. Hastelloy C-276*8 (Thickness: 0.0055 inch (0.14 mm))T................................................. Tantalum*10 J........ Hastelloy C-276*8*9

(Thickness: 0.006 inch (0.15 mm))Sealingfacematerial (Pipeandbase)

C.............................................. 316 SSTS.............................................. 316LSSTH.............................................. Hastelloy C-276*8

Diaphragm diameter 9............................................ Diaphragm O.D: 3.54-inch (90 mm)*9

6............................................ Diaphragm O.D: 2.4-inch (61 mm)Diaphragm option A......................................... Gold-plated diaphragm*6

P......................................... With platinum plate*7

N......................................... None-------- N...................................... Always NCapillary connection B................................... BackofdiaphragmsealunitFlangesize*4 -4................................ 4-inch (100 mm)

-3................................ 3-inch (80 mm)Flange standards J.............................. JIS

A.............................. ANSIP.............................. JPID.............................. DIN

Page 42: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

42

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Sep. 27, 2018-00

Flange pressure rating 1........................... class150 A........ 10K H........ PN10/162........................... class300 B........ 20K K........ PN25/404........................... class600 C........ 30K5........................... class900 D........ 40K6........................... class1500

Flange type S......................... forgeneraluseFlange material A...................... JIS S25C

B...................... 304 SST*5

C...................... 316 SST*5

S...................... 316LSST*5*11

Extended outside diameter -4.................. 3.78±0.02 inch (96±0.5 mm)-3.................. 2.8±0.02 inch (71±0.5 mm)

Extended length 2................. Length(X2)=1.97±0.02inch(50±0.5mm)4................. Length(X2)=3.94±0.02inch(100±0.5mm)6................. Length(X2)=5.91±0.02inch(150±0.5mm)8................. Length(X2)=7.87±0.03inch(200±0.8mm)

-------- N.............. Always N

Table3a. DiaphragmmaterialandSealingfacematerial

Wettedpartsmaterial*1 [Diaphragm material] [Sealingfacematerial]SC....................... [S]316LSST [C] 316 SSTSS........................ [S]316LSST [S]316LSSTHC....................... [H] Hastelloy C-276*8# [C] 316 SSTHS....................... [H] Hastelloy C-276*8# [S]316LSSTHH....................... [H] Hastelloy C-276*8# [H] Hastelloy C-276*8

TS........................ [T] Tantalum [S]316LSSTVC....................... [V]316LSST [C] 316 SST

(Thickness: 0.0055 inch (0.14 mm))VS........................ [V]316LSST [S]316LSST

(Thickness: 0.005 inch (0.14 mm))JC........................ [J] Hastelloy C-276*8*9# [C] 316 SST

(Thickness: 0.006 inch (0.15 mm))JS........................ [J] Hastelloy C-276*8*9# [S]316LSST

(Thickness: 0.006 inch (0.15 mm))JH........................ [J] Hastelloy C-276*8*9# [H] Hastelloy C-276*8

(Thickness: 0.006 inch (0.15 mm))

*1: Usersmustconsiderthecharacteristicsofselectedwettedpartsmaterialandtheinfluenceofprocessfluids.Theuseofinappropriatematerialscanresultintheleakageofcorrosiveprocessfluidsandcauseinjurytopersonneland/ordamagetoplantfacilities.Itisalsopossiblethatthediaphragmitselfcanbedamagedandthatmaterialfromthebrokendiaphragmandthefillfluidcancontaminatetheuser’sprocessfluids.

Beverycarefulwithhighlycorrosiveprocessfluidssuchashydrochloricacid,sulfuricacid,hydrogensulfide,sodiumhypochlorite,andhightemperaturesteam(150°C[302°F]orabove).ContactYokogawafordetailedinformationofthewetted parts material.

*2: Refertosection12forlimitationofcapillarylength.*3: Applicableforoptioncode/R(Operatingtemperaturecorrection).Incaseof“withoutPVCsheath”,mustbeselectcodeV.*4: NotapplicabletodifferentsizebetweenProcessconnectionsizeandFlangesize.*5: Forgedversionofthematerialmaybeused.*6: ApplicableforDiaphragmmaterialcodeSandH. Insideofisolatingdiaphragms(fillfluidside)aregoldplated,effectiveforhydrogenpermeation.*7: ApplicableforDiaphragmmaterialcodeT.*8: Hastelloy C-276 or N10276.*9: Notapplicableforprocessconnectionsizecode3.*10: Thespecifiedcapillarylengthincludestheextensionlength(X2)andtheflangethickness(t).*11: NotapplicableforflangestandardscodeD.*12: Incaseofcompensationcapillarytype,mustbeselectcode“-C”onsealsystemlocationcode“-L”.*13: Applicableforprocessconnectionsizecode“3”withcapillarylengthmorethan6m.

Page 43: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

43<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Sep. 27, 2018-00

Table3b. ProcesstemperatureandAmbienttemperature

Code Processtemperature*14

Ambienttemperature*17 Workingpressure Specific

gravity*18

Silicone oil*15 (general use) A −10to315°C

(14to599°F)−10to60°C (14to140°F) 2.7kPaabs(0.38psiabs)

toflangeratingpressure

1.07

Silicone oil*15 (general use) B −30to210°C

(−22to410°F)−30to60°C

(−22to140°F) 0.94

Silicone oil (low temperature use) F −70to100°C

(−94to212°F)−30to60°C

(−22to140°F)100kPaabs(atmosphericpressure)

toflangepressurerating 0.88

Fluorinated oil*16 (oil-prohibiteduse) D −20to120°C

(−4to248°F)−10to60°C (14to140°F)

51kPaabs(7.4psiabs) toflangeratingpressure 1.90 to 1.92

Ethylene glycol (low temperature use) E −50to100°C

(−58to212°F)−40to60°C

(−40to140°F) 100kPaabs(atmosphericpressure) toflangepressurerating

1.09

Propylene glycol P −10to120°C (14to248°F)

−10to60°C (14to140°F) 1.04

Note: Thedifferentialpressuretransmittershouldbeinstalledatleast600mmbelowthehighpressure(HP)processconnection. However,thisvalue(600mm)maybeaffectedbyambienttemperature,operatingpressure,fillfluidormaterialofthe

wetted diaphragm. ContactYOKOGAWAwhenthetransmittercannotbeinstalledatleast600mmbelowtheHPprocessconnection.

*14: Seefigure1a,1b‘WorkingPressureandProcessTemperature.’*15: IncaseofdiaphragmmaterialcodeT(Tantalum),processtemperaturelimitisupto200°C(392°F).*16: EvenincasewherefillfluidcodeD(fluorinatedoil)isselected,ifdegreasecleansingtreatmentorbothdegreasecleansing

anddehydratingtreatmentforthewettedpartsisrequired,specifyoptioncodeK31orK35.*17: Thisambienttemperatureisthetransmitterambienttemperature.*18: Approximatevaluesatatemperatureof25°C(77°F)

Page 44: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

44

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Sep. 27, 2018-00

3.2 4-inch(100mm)/3-inch(80mm)Raisedface(RF)ExtendedtypeHighvacuum/Hightemp.andhighvacuumuseCapillaryConnectionStyle:Backofdiaphragmsealunit

F49E.ai

Model SuffixCodes DescriptionC80FE ............................................................................... Remote Mount Flanged Diaphragm Seal (Extended type)Seal system location

-H........................................................................... forhighpressureside-L........................................................................... forlowpressureside

Sealfillfluid ......................................................................... Refertotable3d.Transmitter connection type -S..................................................................... forgeneraluse

Capillary length*2*8

1.................................................................... 1 m 6..................... 6 m2.................................................................... 2 m 7..................... 7 m3.................................................................... 3 m 8..................... 8 m4.................................................................... 4 m 9..................... 9 m5.................................................................... 5 m A..................... 10 m

Capillary inside diameter 2................................................................. Capillary I.D. 2.03 mm

Capillary Style [Usage] [Sheath style]1.............................................................. High temp. and

high vacuum usewith PVC sheath

2.............................................................. without PVC sheath3.............................................................. with PVC sheath red-color5.............................................................. High vacuum use with PVC sheath6.............................................................. without PVC sheath7.............................................................. with PVC sheath red-color

CapillaryTubeConnection S............................................................ forgeneraluse

Process Connection size*3

-4........................................................ 4-inch (100 mm)-3........................................................ 3-inch (80 mm)

Sealing Face F...................................................... Raisedface(RF)Gasketcontactsurface 1.................................................... Serration (ANSI B16.5)

(forANSIflangewithsealingfacematerialCandS)2.................................................... Flat (no serration)

Diaphragm material S................................................. 316LSSTH................................................. Hastelloy C-276*7

T................................................. Tantalum*6

Sealingfacematerial (Pipe and Base)

C.............................................. 316 SSTS.............................................. 316LSST

Diaphragm diameter 9............................................ Diaphragm O.D: 3.54-inch (90 mm)*9

6............................................ Diaphragm O.D: 2.4-inch (61 mm)Diaphragm option A......................................... Gold-plated diaphragm*5

N......................................... None-------- N...................................... Always NCapillary connection B................................... BackofdiaphragmsealunitFlangesize*3 -4................................ 4-inch (100 mm)

-3................................ 3-inch (80 mm)Flange standards J.............................. JIS

A.............................. ANSIP.............................. JPID.............................. DIN

Page 45: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

45<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Sep. 27, 2018-00

Flange pressure rating 1........................... class150 A........ 10K H........ PN10/162........................... class300 B........ 20K K........ PN25/404........................... class600 C........ 30K5........................... class900 D........ 40K6........................... class1500

Flange type S......................... forgeneraluseFlange material A...................... JIS S25C

B...................... 304 SST*4

C...................... 316 SST*4

S...................... 316LSST*4*9*10

Extended outside diameter -4.................. 3.78±0.02 inch (96±0.5 mm)-3.................. 2.8±0.02 inch (71±0.5 mm)

Extended length 2................. Length(X2)=1.97±0.02inch(50±0.5mm)4................. Length(X2)=3.94±0.02inch(100±0.5mm)6................. Length(X2)=5.91±0.02inch(150±0.5mm)8................. Length(X2)=7.87±0.03inch(200±0.8mm)

-------- N.............. Always N

Table3c. DiaphragmmaterialandSealingfacematerial

Wettedpartsmaterial*1 [Diaphragm material] [Sealingfacematerial]SC....................... [S]316LSST [C] 316 SSTSS........................ [S]316LSST [S]316LSSTHC....................... [H] Hastelloy C-276*7# [C] 316 SSTHS....................... [H] Hastelloy C-276*7# [S]316LSSTTS........................ [T] Tantalum*6 [S]316LSST

*1: Usersmustconsiderthecharacteristicsofselectedwettedpartsmaterialandtheinfluenceofprocessfluids.Theuseofinappropriatematerialscanresultintheleakageofcorrosiveprocessfluidsandcauseinjurytopersonneland/ordamagetoplantfacilities.Itisalsopossiblethatthediaphragmitselfcanbedamagedandthatmaterialfromthebrokendiaphragmandthefillfluidcancontaminatetheuser’sprocessfluids.

Beverycarefulwithhighlycorrosiveprocessfluidssuchashydrochloricacid,sulfuricacid,hydrogensulfide,sodiumhypochlorite,andhightemperaturesteam(150°C[302°F]orabove).ContactYokogawafordetailedinformationofthewetted parts material.

*2: Refertosection12forlimitationofcapillarylength.*3: NotapplicabletodifferentsizebetweenProcessconnectionsizeandFlangesize.*4: Forgedversionofthematerialmaybeused.*5: ApplicableforDiaphragmmaterialcodeSandH. Insideofisolatingdiaphragms(fillfluidside)aregoldplated,effectiveforhydrogenpermeation.*6: Notapplicableforsealfillfluidcode2.*7: Hastelloy C-276 or N10276.*8: Thespecifiedcapillarylengthincludestheextensionlength(X2)andtheflangethickness(t).*9: Notapplicableforprocessconnectionsizecode3.*10: NotapplicableforflangestandardscodeD.

The‘#’marksindicatetheconstructionmaterialsconformtoNACEmaterialrecommendationsperMR0175(2003).Pleaserefertolateststandardsfordetails.

Page 46: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

46

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Sep. 27, 2018-00

Table3d. ProcesstemperatureandAmbienttemperature

Code Processtemperature*11

Ambienttemperature*13 Workingpressure Specific

gravity*15

Silicone oil*12 (high temp. and high vacuum use)

1 −10to250°C (14to482°F)

−10to60°C*14 (14to140°F)

0.013kPaabs (0.0019psiabs)

toflangeratingpressure

1.07

Silicone oil (high temp. and high vacuum use)

2 10to315°C (50to599°F)

10to60°C*14 (50to140°F) 1.09

Silicone oil (high vacuum use) 4 −10to100°C

(14to212°F)−10to60°C*14 (14to140°F) 1.07

Note: Thedifferentialpressuretransmittershouldbeinstalledatleast600mmbelowthehighpressure(HP)processconnection. However,thisvalue(600mm)maybeaffectedbyambienttemperature,operatingpressure,fillfluidormaterialofthe

wetted diaphragm. ContactYOKOGAWAwhenthetransmittercannotbeinstalledatleast600mmbelowtheHPprocessconnection.

*11: Seefigure1e,1f‘WorkingPressureandProcessTemperature.’*12: IncaseofdiaphragmmaterialcodeT(Tantalum),processtemperaturelimitisupto200°C(392°F).*13: Thisambienttemperatureisthetransmitterambienttemperature.*14: Incaseofprocessconnectionsizecode3,ambienttemperaturelimitisupto50°C(122°F).*15: Approximatevaluesatatemperatureof25°C(77°F)

Page 47: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

47<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Sep. 27, 2018-00

4. RemoteMountFlangedDiaphragmSeal(InnerDiaphragmtype)4.1 1/2-inch(15mm)/3/4-inch(20mm)1-inch(25mm)

Adapterconnectiontype,Raisedface(RF)forgeneraluse,CapillaryConnectionStyle:Backofdiaphragmsealunit

F50E.ai

Model SuffixCodes DescriptionC81FA ............................................................................... Inner Diaphragm, Adapter connection seal (Bundled capillary type)*2

C82FA ............................................................................... Inner Diaphragm, Adapter connection seal (Standard type)Seal system location

-H........................................................................... Standardtypeforhighpressureside-L........................................................................... Standardtypeforlowpressureside-B........................................................................... Bundled capillary type (1 m separated)*4

Sealfillfluid ......................................................................... Refertotable4b.Transmitter connection type -S..................................................................... forgeneraluse

Capillary length*5

1.................................................................... 1 m*3 6..................... 6 m B........................ 11 m2.................................................................... 2 m 7..................... 7 m C........................ 12 m3.................................................................... 3 m 8..................... 8 m D........................ 13 m4.................................................................... 4 m 9..................... 9 m E........................ 14 m5.................................................................... 5 m A..................... 10 m F........................ 15 m

Capillary inside diameter

2.................................................................1.................................................................

Capillary I.D. 2.03 mmCapillary I.D. 1.3 mm*15

Capillary Style [Usage] [Sheath style]S.............................................................. forgeneraluse with PVC sheathV.............................................................. without PVC sheathW............................................................. with PVC sheath red-color

CapillaryTubeConnection S............................................................ forgeneraluse

Inner Diaphragm Type -9........................................................ Inner Diaphragm Type-------- S...................................................... Always S-------- 2.................................................... Always 2Diaphragm material S................................................. 316LSST

H................................................. Hastelloy C-276*8

T................................................. Tantalum*16

Wetted Parts Material (ExceptforFlange)

S.............................................. 316LSSTH.............................................. Hastelloy C-276*8

T.............................................. TantalumDiaphragm diameter 6............................................ Diaphragm O.D: 2.4-inch (61 mm)Diaphragm option A......................................... Gold-plated diaphragm*7

N......................................... None-------- N...................................... Always NCapillary connection B................................... BackofdiaphragmsealunitFlangesize -6................................ 1/2-inch(15mm)

-7................................ 3/4-inch(20mm)-1................................ 1-inch (25 mm)

Flange standards J.............................. JISA.............................. ANSIP.............................. JPI

Flange pressure rating 1........................... class150 A............ 10K D............ 40K2........................... class300 B............ 20K4........................... class600 C............ 30K

Sealing Face F......................... Raisedface(RF)Flat(noserration)G......................... Raisedface(RF)WithSerration(ANSIB16.5)

(forANSIflangeonly)Flange material (Adapter, Vent plug, Vent screw)

C...................... 316 SST*6

S...................... 316LSST*6

Page 48: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

48

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Sep. 27, 2018-00

Flange Usage -S.................. forgeneraluse*9

-P.................. forgeneraluse(Gasketmaterial:PTFETeflon)*10

-H.................. forhightemperatureuse(Processtemperature:250to315°C)*11*12

Vent Plug Style S................. forgeneraluse(withtwoventplugs)*13

L................. With two long vent plugs*14

N................. Without vent plug-------- N.............. Always N

Note: Studboltsandnutsareattachedfortheadapter(Material:Studbolt….B7,NUT….304SST) Incaseofdifferentialtransmitterwithbothsidediaphragmseal:2pcs Incaseofdifferentialtransmitterwithsinglediaphragmsealorgaugetransmitterwithdiaphragmseal:1pc

Table4a. DiaphragmmaterialandSealingfacematerial

Wettedpartsmaterial*1 [Diaphragm material] [Sealingfacematerial]SS........................ [S]316LSST [S]316LSSTHH....................... [H] Hastelloy C-276*8# [H] Hastelloy C-276*8#TT........................ [T] Tantalum [T] Tantalum

*1: Usersmustconsiderthecharacteristicsofselectedwettedpartsmaterialandtheinfluenceofprocessfluids.Theuseofinappropriatematerialscanresultintheleakageofcorrosiveprocessfluidsandcauseinjurytopersonneland/ordamagetoplantfacilities.Itisalsopossiblethatthediaphragmitselfcanbedamagedandthatmaterialfromthebrokendiaphragmandthefillfluidcancontaminatetheuser’sprocessfluids. Beverycarefulwithhighlycorrosiveprocessfluidssuchashydrochloricacid,sulfuricacid,hydrogensulfide,sodiumhypochlorite,andhightemperaturesteam(150°C[302°F]orabove).ContactYokogawafordetailedinformationofthewetted parts material.

*2: Notapplicableforgaugetransmitteranddifferentialtransmitterwithsinglesealtype.*3: Incasewherecapillarylengthcode1(1m),themodelcodemustbeselectedforC82FA.NotapplicableforC81FA.*4: IncasewhereModelcodeF81FAisselected,ItmustbeSelectedsealsystemlocationcodeB.*5: Refertosection12forlimitationofcapillarylength.*6: Forgedversionofthematerialmaybeused.*7: ApplicableforDiaphragmmaterialcodeSandH. Insideofisolatingdiaphragms(fillfluidside)aregoldplated,effectiveforhydrogenpermeation.*8: Hastelloy C-276 or N10276.*9: Gasketmaterialfortransmittersideis316LSSTwithPTFETefloncoating.*10: ApplicableforDiaphragmmaterialcodeT.*11: WhenselectingFlangeusagecodeH(forHightemperatureuse),Drain/ventareweldedtotheflange.*12: NotapplicableforDiaphragmmaterialcodeT.*13: NotapplicableforFlangeusagecodeH.*14: Totallength:119mm(standard:34mm);TotallengthwhencombiningwithoptioncodeK31andK35:130mm.*15: Applicableforcapillarylengthmorethan6m.The‘#’marksindicatetheconstructionmaterialsconformtoNACEmaterialrecommendationsperMR0175(2003).Pleaserefertolateststandardsfordetails.

Page 49: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

49<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Sep. 27, 2018-00

Table4b. ProcesstemperatureandAmbienttemperature

Code Processtemperature*16

Ambienttemperature*19 Workingpressure Specific

gravity*20

Silicone oil*17*21 (general use) A −10to315°C

(14to599°F)−10to60°C (14to140°F) 2.7kPaabs(0.38psiabs)

toflangeratingpressure

1.07

Silicone oil*17 (general use) B −30to210°C

(−22to410°F)−30to60°C

(−22to140°F) 0.94

Silicone oil (low temperature use) F −70to100°C

(−94to212°F)−30to60°C

(−22to140°F)100kPaabs(atmosphericpressure)

toflangepressurerating 0.88

Fluorinated oil*18 (oil-prohibiteduse) D −20to120°C

(−4to248°F)−10to60°C (14to140°F)

51kPaabs(7.4psiabs) toflangeratingpressure 1.90 to 1.92

Ethylene glycol (low temperature use) E −50to100°C

(−58to212°F)−40to60°C

(−40to140°F) 100kPaabs(atmosphericpressure) toflangepressurerating

1.09

Propylene glycol P −10to120°C (14to248°F)

−10to60°C (14to140°F) 1.04

Note: Thedifferentialpressuretransmittershouldbeinstalledatleast600mmbelowthehighpressure(HP)processconnection. However,thisvalue(600mm)maybeaffectedbyambienttemperature,operatingpressure,fillfluidormaterialofthewetted diaphragm. ContactYOKOGAWAwhenthetransmittercannotbeinstalledatleast600mmbelowtheHPprocessconnection.

*16: Seefigure1a,1b‘WorkingPressureandProcessTemperature.’*17: IncaseofdiaphragmmaterialcodeT(Tantalum),processtemperaturelimitisupto200°C(392°F).*18: EvenincasewherefillfluidcodeD(fluorinatedoil)isselected,ifdegreasecleansingtreatmentorbothdegreasecleansing

anddehydratingtreatmentforthewettedpartsisrequired,specifyoptioncodeK31orK35.*19: Thisambienttemperatureisthetransmitterambienttemperature.*20: Approximatevaluesatatemperatureof25°C(77°F)*21: Fortheprocesswheretheprocesstemperatureexceeds250°C,specifyFlangeusagecode–H.

Page 50: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

50

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Sep. 27, 2018-00

4.2 1/2-inch(15mm)/3/4-inch(20mm)/1-inch(25mm)Adapterconnectiontype,Ringtypejoint(RJ)forgeneraluse,CapillaryConnectionStyle:Backofdiaphragmsealunit

F51E.ai

Model SuffixCodes DescriptionC81FA ............................................................................... Inner Diaphragm, Adapter connection seal (Bundled capillary type)*2

C82FA Inner Diaphragm, Adapter connection seal (Standard type)Seal system location

-H........................................................................... Standardtypeforhighpressureside-L........................................................................... Standardtypeforlowpressureside-B........................................................................... Bundled capillary type (1 m separated)*4

Sealfillfluid ......................................................................... Refertotable4d.Transmitter connection type -S..................................................................... forgeneraluse

Capillary length*5

1.................................................................... 1 m*3 6..................... 6 m B..................... 11 m2.................................................................... 2 m 7..................... 7 m C..................... 12 m3.................................................................... 3 m 8..................... 8 m D..................... 13 m4.................................................................... 4 m 9..................... 9 m E..................... 14 m5.................................................................... 5 m A..................... 10 m F..................... 15 m

Capillary inside diameter

2.................................................................1.................................................................

Capillary I.D. 2.03 mmCapillary I.D. 1.3 mm*15

Capillary Style [Usage] [Sheath style]S.............................................................. forgeneraluse with PVC sheathV.............................................................. without PVC sheathW............................................................. with PVC sheath red-color

CapillaryTubeConnection S............................................................ forgeneraluse

Inner Diaphragm Type -9........................................................ Inner Diaphragm Type-------- S...................................................... Always S-------- 2.................................................... Always 2Diaphragm material S................................................. 316LSST

H................................................. Hastelloy C-276*8

T................................................. Tantalum*16

Wetted Parts Material (ExceptforFlange)

S.............................................. 316LSSTH.............................................. Hastelloy C-276*8

T.............................................. TantalumDiaphragm diameter 6............................................ Diaphragm O.D: 2.4-inch (61 mm)Diaphragm option A......................................... Gold-plated diaphragm*7

N......................................... None-------- N...................................... Always NCapillary connection B................................... BackofdiaphragmsealunitFlangesize -6................................ 1/2-inch(15mm)

-7................................ 3/4-inch(20mm)-1................................ 1-inch (25 mm)

Flange standards A.............................. ANSIP.............................. JPI

Flange pressure rating 2........................... class3004........................... class600

Sealing Face J......................... Ring type joint (RJ)Flange material (Adapter, Vent plug, Vent screw)

C...................... 316 SST*6

S...................... 316LSST*6

Flange Usage -S.................. forgeneraluse*9

-P.................. forgeneraluse(Gasketmaterial:PTFETeflon)*10

-H.................. forhightemperatureuse(Processtemperature:250to315°C)*11*12

Page 51: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

51<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Sep. 27, 2018-00

Vent Plug Style S................. forgeneraluse(withtwoventplugs)*13

L................. With two long vent plugs*14

N................. Without vent plug-------- N.............. Always N

Note: Studboltsandnutsareattachedfortheadapter(Material:Studbolt….B7,NUT….304SST) Incaseofdifferentialtransmitterwithbothsidediaphragmseal:2pcs Incaseofdifferentialtransmitterwithsinglediaphragmsealorgaugetransmitterwithdiaphragmseal:1pc

Table4c. DiaphragmmaterialandSealingfacematerial

Wettedpartsmaterial*1 [Diaphragm material] [Sealingfacematerial]SS........................ [S]316LSST [S]316LSSTHH....................... [H] Hastelloy C-276*8# [H] Hastelloy C-276*8#TT........................ [T] Tantalum [T] Tantalum

*1: Usersmustconsiderthecharacteristicsofselectedwettedpartsmaterialandtheinfluenceofprocessfluids.Theuseofinappropriatematerialscanresultintheleakageofcorrosiveprocessfluidsandcauseinjurytopersonneland/ordamagetoplantfacilities.Itisalsopossiblethatthediaphragmitselfcanbedamagedandthatmaterialfromthebrokendiaphragmandthefillfluidcancontaminatetheuser’sprocessfluids. Beverycarefulwithhighlycorrosiveprocessfluidssuchashydrochloricacid,sulfuricacid,hydrogensulfide,sodiumhypochlorite,andhightemperaturesteam(150°C[302°F]orabove).ContactYokogawafordetailedinformationofthewetted parts material.

*2: Notapplicableforgaugetransmitteranddifferentialtransmitterwithsinglesealtype.*3: Incasewherecapillarylengthcode1(1m),themodelcodemustbeselectedforC82FA.NotapplicableforC81FA.*4: IncasewhereModelcodeF81FAisselected,ItmustbeSelectedsealsystemlocationcodeB.*5: Refertosection12forlimitationofcapillarylength.*6: Forgedversionofthematerialmaybeused.*7: ApplicableforDiaphragmmaterialcodeSandH.

Insideofisolatingdiaphragms(fillfluidside)aregoldplated,effectiveforhydrogenpermeation.*8: Hastelloy C-276 or N10276.*9: Gasketmaterialfortransmittersideis316LSSTwithPTFETefloncoating.*10: ApplicableforDiaphragmmaterialcodeT.*11: WhenselectingFlangeusagecodeH(forHightemperatureuse),Drain/ventareweldedtotheflange.*12: NotapplicableforDiaphragmmaterialcodeT.*13: NotapplicableforFlangeusagecodeH.*14: Totallength:119mm(standard:34mm);TotallengthwhencombiningwithoptioncodeK31andK35:130mm.*15: Applicableforcapillarylengthmorethan6m.The‘#’marksindicatetheconstructionmaterialsconformtoNACEmaterialrecommendationsperMR0175(2003).Pleaserefertolateststandardsfordetails.

Table4d. ProcesstemperatureandAmbienttemperature

Code Processtemperature*16

Ambienttemperature*19 Workingpressure Specific

gravity*20

Silicone oil*17*21 (general use) A −10to315°C

(14to599°F)−10to60°C (14to140°F) 2.7kPaabs(0.38psiabs)

toflangeratingpressure

1.07

Silicone oil*17 (general use) B −30to210°C

(−22to410°F)−30to60°C

(−22to140°F) 0.94

Silicone oil (low temperature use) F −70to100°C

(−94to212°F)−30to60°C

(−22to140°F)100kPaabs(atmosphericpressure)

toflangepressurerating 0.88

Fluorinated oil*18 (oil-prohibiteduse) D −20to120°C

(−4to248°F)−10to60°C (14to140°F)

51kPaabs(7.4psiabs) toflangeratingpressure 1.90 to 1.92

Ethylene glycol (low temperature use) E −50to100°C

(−58to212°F)−40to60°C

(−40to140°F) 100kPaabs(atmosphericpressure) toflangepressurerating

1.09

Propylene glycol P −10to120°C (14to248°F)

−10to60°C (14to140°F) 1.04

Note: Thedifferentialpressuretransmittershouldbeinstalledatleast600mmbelowthehighpressure(HP)processconnection. However,thisvalue(600mm)maybeaffectedbyambienttemperature,operatingpressure,fillfluidormaterialofthewetted diaphragm. ContactYOKOGAWAwhenthetransmittercannotbeinstalledatleast600mmbelowtheHPprocessconnection.

*16: Seefigure1a,1b‘WorkingPressureandProcessTemperature.’*17: IncaseofdiaphragmmaterialcodeT(Tantalum),processtemperaturelimitisupto200°C(392°F).*18: EvenincasewherefillfluidcodeD(fluorinatedoil)isselected,ifdegreasecleansingtreatmentorbothdegreasecleansing

anddehydratingtreatmentforthewettedpartsisrequired,specifyoptioncodeK31orK35.*19: Thisambienttemperatureisthetransmitterambienttemperature.*20: Approximatevaluesatatemperatureof25°C(77°F)*21: Fortheprocesswheretheprocesstemperatureexceeds250°C,specifyFlangeusagecode–H.

Page 52: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

52

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Sep. 27, 2018-00

4.3 1/2-inch(15mm)/3/4-inch(20mm)/1-inch(25mm)Flangeconnectiontype,Raisedface(RF)forgeneraluse,CapillaryConnectionStyle:Backofdiaphragmsealunit

F52E.ai

Model SuffixCodes DescriptionC81FD ............................................................................... Inner Diaphragm, Flange connection seal (Bundled capillary type)*2

C82FD ............................................................................... Inner Diaphragm, Flange connection seal (Standard type)Seal system location

-H........................................................................... Standardtypeforhighpressureside-L........................................................................... Standardtypeforlowpressureside-B........................................................................... Bundled capillary type (1 m separated)*4

Sealfillfluid ......................................................................... Refertotable4f.Transmitter connection type -S..................................................................... forgeneraluse

Capillary length*5

1.................................................................... 1 m*3 6..................... 6 m B........................ 11 m2.................................................................... 2 m 7..................... 7 m C........................ 12 m3.................................................................... 3 m 8..................... 8 m D........................ 13 m4.................................................................... 4 m 9..................... 9 m E........................ 14 m5.................................................................... 5 m A..................... 10 m F........................ 15 m

Capillary inside diameter

2.................................................................1.................................................................

Capillary I.D. 2.03 mmCapillary I.D. 1.3 mm*15

Capillary Style [Usage] [Sheath style]S.............................................................. forgeneraluse with PVC sheathV.............................................................. without PVC sheathW............................................................. with PVC sheath red-color

CapillaryTubeConnection S............................................................ forgeneraluse

Inner Diaphragm Type -9........................................................ Inner Diaphragm Type-------- S...................................................... Always S-------- 2.................................................... Always 2Diaphragm material S................................................. 316LSST

H................................................. Hastelloy C-276*8

T................................................. Tantalum*16

Wetted Parts Material (ExceptforFlange)

S.............................................. 316LSSTH.............................................. Hastelloy C-276*8

T.............................................. TantalumDiaphragm diameter 6............................................ Diaphragm O.D: 2.4-inch (61 mm)Diaphragm option A......................................... Gold-plated diaphragm*7

N......................................... None-------- N...................................... Always NCapillary connection B................................... BackofdiaphragmsealunitFlangesize -6................................ 1/2-inch(15mm)

-7................................ 3/4-inch(20mm)-1................................ 1-inch (25 mm)

Flange standards J.............................. JISA.............................. ANSIP.............................. JPI

Flange pressure rating 1........................... class150 A............ 10K D............ 40K2........................... class300 B............ 20K4........................... class600 C............ 30K

Sealing Face F......................... Raisedface(RF)Flat(noserration)G......................... Raisedface(RF)WithSerration(ANSIB16.5)

(forANSIflangeonly)Flange material (Flange, Pipe, Base, Vent plug, Vent screw)

C...................... 316 SST*6

S...................... 316LSST*6

Page 53: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

53<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Sep. 27, 2018-00

Flange Usage -S.................. forgeneraluse*9

-P.................. forgeneraluse(Gasketmaterial:PTFETeflon)*10

-H.................. forhightemperatureuse(Processtemperature:250to315°C)*11*12

Vent Plug Style S................. forgeneraluse(withtwoventplugs)*13

L................. With two long vent plugs*14

N................. Without vent plug-------- N.............. Always N

Table4e. DiaphragmmaterialandSealingfacematerial

Wettedpartsmaterial*1 [Diaphragm material] [Sealingfacematerial]SS........................ [S]316LSST [S]316LSSTHH....................... [H] Hastelloy C-276*8# [H] Hastelloy C-276*8#TT........................ [T] Tantalum [T] Tantalum

*1: Usersmustconsiderthecharacteristicsofselectedwettedpartsmaterialandtheinfluenceofprocessfluids.Theuseofinappropriatematerialscanresultintheleakageofcorrosiveprocessfluidsandcauseinjurytopersonneland/ordamagetoplantfacilities.Itisalsopossiblethatthediaphragmitselfcanbedamagedandthatmaterialfromthebrokendiaphragmandthefillfluidcancontaminatetheuser’sprocessfluids. Beverycarefulwithhighlycorrosiveprocessfluidssuchashydrochloricacid,sulfuricacid,hydrogensulfide,sodiumhypochlorite,andhightemperaturesteam(150°C[302°F]orabove).ContactYokogawafordetailedinformationofthewetted parts material.

*2: Notapplicableforgaugetransmitteranddifferentialtransmitterwithsinglesealtype.*3: Incasewherecapillarylengthcode1(1m),themodelcodemustbeselectedforC82FD.NotapplicableforC81FD.*4: IncasewhereModelcodeF81FDisselected,ItmustbeSelectedsealsystemlocationcodeB.*5: Refertosection12forlimitationofcapillarylength.*6: Forgedversionofthematerialmaybeused.*7: ApplicableforDiaphragmmaterialcodeSandH.

Insideofisolatingdiaphragms(fillfluidside)aregoldplated,effectiveforhydrogenpermeation.*8: Hastelloy C-276 or N10276.*9: Gasketmaterialfortransmittersideis316LSSTwithPTFETefloncoating.*10: ApplicableforDiaphragmmaterialcodeT.*11: WhenselectingFlangeusagecodeH(forHightemperatureuse),Drain/ventareweldedtotheflange.*12: NotapplicableforDiaphragmmaterialcodeT.*13: NotapplicableforFlangeusagecodeH.*14: Totallength:119mm(standard:34mm);TotallengthwhencombiningwithoptioncodeK31andK35:130mm.*15: Applicableforcapillarylengthmorethan6m.The‘#’marksindicatetheconstructionmaterialsconformtoNACEmaterialrecommendationsperMR0175(2003).Pleaserefertolateststandardsfordetails.

Table4f. ProcesstemperatureandAmbienttemperature

Code Processtemperature*16

Ambienttemperature*19 Workingpressure Specific

gravity*20

Silicone oil*17*21 (general use) A −10to315°C

(14to599°F)−10to60°C (14to140°F) 2.7kPaabs(0.38psiabs)

toflangeratingpressure

1.07

Silicone oil*17 (general use) B −30to210°C

(−22to410°F)−30to60°C

(−22to140°F) 0.94

Silicone oil (low temperature use) F −70to100°C

(−94to212°F)−30to60°C

(−22to140°F)100kPaabs(atmosphericpressure)

toflangepressurerating 0.88

Fluorinated oil*18 (oil-prohibiteduse) D −20to120°C

(−4to248°F)−10to60°C (14to140°F)

51kPaabs(7.4psiabs) toflangeratingpressure 1.90 to 1.92

Ethylene glycol (low temperature use) E −50to100°C

(−58to212°F)−40to60°C

(−40to140°F) 100kPaabs(atmosphericpressure) toflangepressurerating

1.09

Propylene glycol P −10to120°C (14to248°F)

−10to60°C (14to140°F) 1.04

Note: Thedifferentialpressuretransmittershouldbeinstalledatleast600mmbelowthehighpressure(HP)processconnection. However,thisvalue(600mm)maybeaffectedbyambienttemperature,operatingpressure,fillfluidormaterialofthewetted diaphragm. ContactYOKOGAWAwhenthetransmittercannotbeinstalledatleast600mmbelowtheHPprocessconnection.

*16: Seefigure1a,1b‘WorkingPressureandProcessTemperature.’*17: IncaseofdiaphragmmaterialcodeT(Tantalum),processtemperaturelimitisupto200°C(392°F).*18: EvenincasewherefillfluidcodeD(fluorinatedoil)isselected,ifdegreasecleansingtreatmentorbothdegreasecleansing

anddehydratingtreatmentforthewettedpartsisrequired,specifyoptioncodeK31orK35.*19: Thisambienttemperatureisthetransmitterambienttemperature.*20: Approximatevaluesatatemperatureof25°C(77°F)*21: Fortheprocesswheretheprocesstemperatureexceeds250°C,specifyFlangeusagecode–H.

Page 54: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

54

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Sep. 27, 2018-00

4.4 1/2-inch(15mm)/3/4-inch(20mm)/1-inch(25mm)Flangeconnectiontype,Ringtypejoint(RJ)forgeneraluse,CapillaryConnectionStyle:Backofdiaphragmsealunit

F53E.ai

Model SuffixCodes DescriptionC81FD ............................................................................... Inner Diaphragm, Flange connection seal (Bundled capillary type)*2

C82FD ............................................................................... Inner Diaphragm, Flange connection seal (Standard type)Seal system location

-H........................................................................... Standardtypeforhighpressureside-L........................................................................... Standardtypeforlowpressureside-B........................................................................... Bundled capillary type (1 m separated)*4

Sealfillfluid ......................................................................... Refertotable4h.Transmitter connection type -S..................................................................... forgeneraluse

Capillary length*5

1.................................................................... 1 m*3 6..................... 6 m B..................... 11 m2.................................................................... 2 m 7..................... 7 m C..................... 12 m3.................................................................... 3 m 8..................... 8 m D..................... 13 m4.................................................................... 4 m 9..................... 9 m E..................... 14 m5.................................................................... 5 m A..................... 10 m F..................... 15 m

Capillary inside diameter

2.................................................................1.................................................................

Capillary I.D. 2.03 mmCapillary I.D. 1.3 mm*15

Capillary Style [Usage] [Sheath style]S.............................................................. forgeneraluse with PVC sheathV.............................................................. without PVC sheathW............................................................. with PVC sheath red-color

CapillaryTubeConnection S............................................................ forgeneraluse

Inner Diaphragm Type -9........................................................ Inner Diaphragm Type-------- S...................................................... Always S-------- 2.................................................... Always 2Diaphragm material S................................................. 316LSST

H................................................. Hastelloy C-276*8

T................................................. Tantalum*16

Wetted Parts Material (ExceptforFlange)

S.............................................. 316LSSTH.............................................. Hastelloy C-276*8

T.............................................. TantalumDiaphragm diameter 6............................................ Diaphragm O.D: 2.4-inch (61 mm)Diaphragm option A......................................... Gold-plated diaphragm*7

N......................................... None-------- N...................................... Always NCapillary connection B................................... BackofdiaphragmsealunitFlangesize*3 -6................................ 1/2-inch(15mm)

-7................................ 3/4-inch(20mm)-1................................ 1-inch (25 mm)

Flange standards A.............................. ANSIP.............................. JPI

Flange pressure rating 2........................... class3004........................... class600

Sealing Face J......................... Ring type joint (RJ)Flange material (Flange, Pipe, Base, Vent plug, Vent screw)

C...................... 316 SST*6

S...................... 316LSST*6

Flange Usage -S.................. forgeneraluse*9

-P.................. forgeneraluse(Gasketmaterial:PTFETeflon)*10

-H.................. forhightemperatureuse(Processtemperature:250to315°C)*11*12

Vent Plug Style S................. forgeneraluse(withtwoventplugs)*13

L................. With two long vent plugs*14

N................. Without vent plug-------- N.............. Always N

Page 55: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

55<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Sep. 27, 2018-00

Table4g. DiaphragmmaterialandSealingfacematerial

Wettedpartsmaterial*1 [Diaphragm material] [Sealingfacematerial]

SS........................ [S]316LSST [S]316LSST

HH....................... [H] Hastelloy C-276*8# [H] Hastelloy C-276*8#

TT........................ [T] Tantalum [T] Tantalum

*1: Usersmustconsiderthecharacteristicsofselectedwettedpartsmaterialandtheinfluenceofprocessfluids.Theuseofinappropriatematerialscanresultintheleakageofcorrosiveprocessfluidsandcauseinjurytopersonneland/ordamagetoplantfacilities.Itisalsopossiblethatthediaphragmitselfcanbedamagedandthatmaterialfromthebrokendiaphragmandthefillfluidcancontaminatetheuser’sprocessfluids. Beverycarefulwithhighlycorrosiveprocessfluidssuchashydrochloricacid,sulfuricacid,hydrogensulfide,sodiumhypochlorite,andhightemperaturesteam(150°C[302°F]orabove).ContactYokogawafordetailedinformationofthewetted parts material.

*2: Notapplicableforgaugetransmitteranddifferentialtransmitterwithsinglesealtype.*3: Incasewherecapillarylengthcode1(1m),themodelcodemustbeselectedforC82FD.NotapplicableforC81FD.*4: IncasewhereModelcodeF81FDisselected,ItmustbeSelectedsealsystemlocationcodeB.*5: Refertosection12forlimitationofcapillarylength.*6: Forgedversionofthematerialmaybeused.*7: ApplicableforDiaphragmmaterialcodeSandH.

Insideofisolatingdiaphragms(fillfluidside)aregoldplated,effectiveforhydrogenpermeation.*8: Hastelloy C-276 or N10276.*9: Gasketmaterialfortransmittersideis316LSSTwithPTFETefloncoating.*10: ApplicableforDiaphragmmaterialcodeT.*11: WhenselectingFlangeusagecodeH(forHightemperatureuse),Drain/ventareweldedtotheflange.*12: NotapplicableforDiaphragmmaterialcodeT.*13: NotapplicableforFlangeusagecodeH.*14: Totallength:119mm(standard:34mm);TotallengthwhencombiningwithoptioncodeK31andK35:130mm.*15: Applicableforcapillarylengthmorethan6m.The‘#’marksindicatetheconstructionmaterialsconformtoNACEmaterialrecommendationsperMR0175(2003).Pleaserefertolateststandardsfordetails.

Table4h. ProcesstemperatureandAmbienttemperature

Code Processtemperature*16

Ambienttemperature*19 Workingpressure Specific

gravity*20

Silicone oil*17*21 (general use) A −10to315°C

(14to599°F)−10to60°C (14to140°F) 2.7kPaabs(0.38psiabs)

toflangeratingpressure

1.07

Silicone oil*17 (general use) B −30to210°C

(−22to410°F)−30to60°C

(−22to140°F) 0.94

Silicone oil (low temperature use) F −70to100°C

(−94to212°F)−30to60°C

(−22to140°F)100kPaabs(atmosphericpressure)

toflangepressurerating 0.88

Fluorinated oil*18 (oil-prohibiteduse) D −20to120°C

(−4to248°F)−10to60°C (14to140°F)

51kPaabs(7.4psiabs) toflangeratingpressure 1.90 to 1.92

Ethylene glycol (low temperature use) E −50to100°C

(−58to212°F)−40to60°C

(−40to140°F) 100kPaabs(atmosphericpressure) toflangepressurerating

1.09

Propylene glycol P −10to120°C (14to248°F)

−10to60°C (14to140°F) 1.04

Note: Thedifferentialpressuretransmittershouldbeinstalledatleast600mmbelowthehighpressure(HP)processconnection. However,thisvalue(600mm)maybeaffectedbyambienttemperature,operatingpressure,fillfluidormaterialofthewetted diaphragm. ContactYOKOGAWAwhenthetransmittercannotbeinstalledatleast600mmbelowtheHPprocessconnection.

*16: Seefigure1a,1b‘WorkingPressureandProcessTemperature.’*17: IncaseofdiaphragmmaterialcodeT(Tantalum),processtemperaturelimitisupto200°C(392°F).*18: EvenincasewherefillfluidcodeD(fluorinatedoil)isselected,ifdegreasecleansingtreatmentorbothdegreasecleansing

anddehydratingtreatmentforthewettedpartsisrequired,specifyoptioncodeK31orK35.*19: Thisambienttemperatureisthetransmitterambienttemperature.*20: Approximatevaluesatatemperatureof25°C(77°F)*21: Fortheprocesswheretheprocesstemperatureexceeds250°C,specifyFlangeusagecode–H.

Page 56: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

56

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Nov. 7, 2016-00

4.5 1/2-inch(15mm)/3/4-inch(20mm)/1-inch(25mm)Adapterconnectiontype,Raisedface(RF)Highvacuum/Hightemp.andhighvacuumuseCapillaryConnectionStyle:Backofdiaphragmsealunit F54E.ai

Model SuffixCodes DescriptionC81FA ............................................................................... Inner Diaphragm, Adapter connection seal (Bundled capillary type)*2

C82FA ............................................................................... Inner Diaphragm, Adapter connection seal (Standard type)Seal system location

-H........................................................................... Standardtypeforhighpressureside-L........................................................................... Standardtypeforlowpressureside-B........................................................................... Bundled capillary type (1 m separated)*4

Sealfillfluid ......................................................................... Refertotable4j.Transmitter connection type -S..................................................................... forgeneraluse

Capillary length*5

1.................................................................... 1 m*3 6..................... 6 m2.................................................................... 2 m 7..................... 7 m3.................................................................... 3 m 8..................... 8 m4.................................................................... 4 m 9..................... 9 m5.................................................................... 5 m A..................... 10 m

Capillary inside diameter 2................................................................. Capillary I.D. 2.03 mm

Capillary Style [Usage] [Sheath style]S.............................................................. forgeneraluse with PVC sheathV.............................................................. without PVC sheathW............................................................. with PVC sheath red-color

CapillaryTubeConnection S............................................................ forgeneraluse

Inner Diaphragm Type -9........................................................ Inner Diaphragm Type-------- S...................................................... Always S-------- 2.................................................... Always 2Diaphragm material S................................................. 316LSST

H................................................. Hastelloy C-276*8

T................................................. Tantalum*16

Wetted Parts Material (ExceptforFlange)

S.............................................. 316LSSTH.............................................. Hastelloy C-276*8

T.............................................. TantalumDiaphragm diameter 6............................................ Diaphragm O.D: 2.4-inch (61 mm)Diaphragm option A......................................... Gold-plated diaphragm*7

N......................................... None-------- N...................................... Always NCapillary connection B................................... BackofdiaphragmsealunitFlangesize -6................................ 1/2-inch(15mm)

-7................................ 3/4-inch(20mm)-1................................ 1-inch (25 mm)

Flange standards J.............................. JISA.............................. ANSIP.............................. JPI

Flange pressure rating 1........................... class150 A............ 10K2........................... class300 B............ 20K4........................... class600 C............ 30K

D............ 40KSealing Face F......................... Raisedface(RF)Flat(noserration)

G......................... Raisedface(RF)WithSerration(ANSIB16.5)(forANSIflangeonly)

Page 57: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

57<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Sep. 27, 2018-00

Flange material (Adapter, Vent plug, Vent screw)

C...................... 316 SST*6

S...................... 316LSST*6

Flange Usage -S.................. forgeneraluse*9

-P.................. forgeneraluse(Gasketmaterial:PTFETeflon)*10

-H.................. forhightemperatureuse(Processtemperature:250to315°C)*11*12

Vent Plug Style S................. forgeneraluse(withtwoventplugs)*13

L................. With two long vent plugs*14

N................. Without vent plug-------- N.............. Always N

Note: Studboltsandnutsareattachedfortheadapter(Material:Studbolt….B7,NUT….304SST) Incaseofdifferentialtransmitterwithbothsidediaphragmseal:2pcs Incaseofdifferentialtransmitterwithsinglediaphragmsealorgaugetransmitterwithdiaphragmseal:1pc

Table4i. DiaphragmmaterialandSealingfacematerial

Wettedpartsmaterial*1 [Diaphragm material] [Sealingfacematerial]SS........................ [S]316LSST [S]316LSSTHH....................... [H] Hastelloy C-276*8# [H] Hastelloy C-276*8#TT........................ [T] Tantalum [T] Tantalum

*1: Usersmustconsiderthecharacteristicsofselectedwettedpartsmaterialandtheinfluenceofprocessfluids.Theuseofinappropriatematerialscanresultintheleakageofcorrosiveprocessfluidsandcauseinjurytopersonneland/ordamagetoplantfacilities.Itisalsopossiblethatthediaphragmitselfcanbedamagedandthatmaterialfromthebrokendiaphragmandthefillfluidcancontaminatetheuser’sprocessfluids. Beverycarefulwithhighlycorrosiveprocessfluidssuchashydrochloricacid,sulfuricacid,hydrogensulfide,sodiumhypochlorite,andhightemperaturesteam(150°C[302°F]orabove).ContactYokogawafordetailedinformationofthewetted parts material.

*2: Notapplicableforgaugetransmitteranddifferentialtransmitterwithsinglesealtype.*3: Incasewherecapillarylengthcode1(1m),themodelcodemustbeselectedforC82FA.NotapplicableforC81FA.*4: IncasewhereModelcodeF81FAisselected,ItmustbeSelectedsealsystemlocationcodeB.*5: Refertosection12forlimitationofcapillarylength.*6: Forgedversionofthematerialmaybeused.*7: ApplicableforDiaphragmmaterialcodeSandH.

Insideofisolatingdiaphragms(fillfluidside)aregoldplated,effectiveforhydrogenpermeation.*8: Hastelloy C-276 or N10276.*9: Gasketmaterialfortransmittersideis316LSSTwithPTFETefloncoating.*10: ApplicableforDiaphragmmaterialcodeT.*11: WhenselectingFlangeusagecodeH(forHightemperatureuse),Drain/ventareweldedtotheflange.*12: NotapplicableforDiaphragmmaterialcodeT.*13: NotapplicableforFlangeusagecodeH.*14: Totallength:119mm(standard:34mm);TotallengthwhencombiningwithoptioncodeK31andK35:130mm.The‘#’marksindicatetheconstructionmaterialsconformtoNACEmaterialrecommendationsperMR0175(2003).Pleaserefertolateststandardsfordetails.

Table4j. ProcesstemperatureandAmbienttemperature

Code Processtemperature*15

Ambienttemperature*17 Workingpressure Specific

gravity*18

Silicone oil*16 (high temp. and high vacuum use)

1 −10to250°C (14to482°F)

−10to50°C (14to122°F)

0.013kPaabs (0.0019psiabs)

toflangeratingpressure

1.07

Silicone oil*19*20 (high temp. and high vacuum use)

2 10to315°C (50to599°F)

10to50°C (50to122°F) 1.09

Silicone oil (high vacuum use) 4 −10to100°C

(14to212°F)−10to50°C (14to122°F) 1.07

Note: Thedifferentialpressuretransmittershouldbeinstalledatleast600mmbelowthehighpressure(HP)processconnection. However,thisvalue(600mm)maybeaffectedbyambienttemperature,operatingpressure,fillfluidormaterialofthewetted diaphragm. ContactYOKOGAWAwhenthetransmittercannotbeinstalledatleast600mmbelowtheHPprocessconnection.

*15: Seefigure1c,1d‘WorkingPressureandProcessTemperature.’*16: IncaseofdiaphragmmaterialcodeT(Tantalum),processtemperaturelimitisupto200°C(392°F).*17: Thisambienttemperatureisthetransmitterambienttemperature.*18: Approximatevaluesatatemperatureof25°C(77°F)*19: Fortheprocesswheretheprocesstemperatureexceeds250°C,specifyFlangeusagecode–H.*20: NotapplicableforDiaphragmmaterialcodeT.

Page 58: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

58

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Nov. 7, 2016-00

4.6 1/2-inch(15mm)/3/4-inch(20mm)/1-inch(25mm)Adapterconnectiontype,Ringtypejoint(RJ)Highvacuum/Hightemp.andhighvacuumuseCapillaryConnectionStyle:Backofdiaphragmsealunit F55E.ai

Model SuffixCodes DescriptionC81FA ............................................................................... Inner Diaphragm, Adapter connection seal (Bundled capillary type)*2

C82FA ............................................................................... Inner Diaphragm, Adapter connection seal (Standard type)Seal system location

-H........................................................................... Standardtypeforhighpressureside-L........................................................................... Standardtypeforlowpressureside-B........................................................................... Bundled capillary type (1 m separated)*4

Sealfillfluid ......................................................................... Refertotable4l.Transmitter connection type -S..................................................................... forgeneraluse

Capillary length*5

1.................................................................... 1 m*3 6..................... 6 m2.................................................................... 2 m 7..................... 7 m3.................................................................... 3 m 8..................... 8 m4.................................................................... 4 m 9..................... 9 m5.................................................................... 5 m A..................... 10 m

Capillary inside diameter 2................................................................. Capillary I.D. 2.03 mm

Capillary Style [Usage] [Sheath style]S.............................................................. forgeneraluse with PVC sheathV.............................................................. without PVC sheathW............................................................. with PVC sheath red-color

CapillaryTubeConnection S............................................................ forgeneraluse

Inner Diaphragm Type -9........................................................ Inner Diaphragm Type-------- S...................................................... Always S-------- 2.................................................... Always 2Diaphragm material S................................................. 316LSST

H................................................. Hastelloy C-276*8

T................................................. Tantalum*16

Wetted Parts Material (ExceptforFlange)

S.............................................. 316LSSTH.............................................. Hastelloy C-276*8

T.............................................. TantalumDiaphragm diameter 6............................................ Diaphragm O.D: 2.4-inch (61 mm)Diaphragm option A......................................... Gold-plated diaphragm*7

N......................................... None-------- N...................................... Always NCapillary connection B................................... BackofdiaphragmsealunitFlangesize -6................................ 1/2-inch(15mm)

-7................................ 3/4-inch(20mm)-1................................ 1-inch (25 mm)

Flange standards A.............................. ANSIP.............................. JPI

Flange pressure rating 2........................... class3004........................... class600

Sealing Face J......................... Ring type joint (RJ)Flange material (Adapter, Vent plug, Vent screw)

C...................... 316 SST*6

S...................... 316LSST*6

Flange Usage -S.................. forgeneraluse*9

-P.................. forgeneraluse(Gasketmaterial:PTFETeflon)*10

-H.................. forhightemperatureuse*11*12

Page 59: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

59<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Sep. 27, 2018-00

Vent Plug Style S................. forgeneraluse(withtwoventplugs)*13

L................. With two long vent plugs*14

N................. Without vent plug-------- N.............. Always N

Note: Studboltsandnutsareattachedfortheadapter(Material:Studbolt….B7,NUT….304SST) Incaseofdifferentialtransmitterwithbothsidediaphragmseal:2pcs Incaseofdifferentialtransmitterwithsinglediaphragmsealorgaugetransmitterwithdiaphragmseal:1pc

Table4k. DiaphragmmaterialandSealingfacematerial

Wettedpartsmaterial*1 [Diaphragm material] [Sealingfacematerial]SS........................ [S]316LSST [S]316LSSTHH....................... [H] Hastelloy C-276*8# [H] Hastelloy C-276*8#TT........................ [T] Tantalum [T] Tantalum

*1: Usersmustconsiderthecharacteristicsofselectedwettedpartsmaterialandtheinfluenceofprocessfluids.Theuseofinappropriatematerialscanresultintheleakageofcorrosiveprocessfluidsandcauseinjurytopersonneland/ordamagetoplantfacilities.Itisalsopossiblethatthediaphragmitselfcanbedamagedandthatmaterialfromthebrokendiaphragmandthefillfluidcancontaminatetheuser’sprocessfluids. Beverycarefulwithhighlycorrosiveprocessfluidssuchashydrochloricacid,sulfuricacid,hydrogensulfide,sodiumhypochlorite,andhightemperaturesteam(150°C[302°F]orabove).ContactYokogawafordetailedinformationofthewetted parts material.

*2: Notapplicableforgaugetransmitteranddifferentialtransmitterwithsinglesealtype.*3: Incasewherecapillarylengthcode1(1m),themodelcodemustbeselectedforC82FA.NotapplicableforC81FA.*4: IncasewhereModelcodeF81FAisselected,ItmustbeSelectedsealsystemlocationcodeB.*5: Refertosection12forlimitationofcapillarylength.*6: Forgedversionofthematerialmaybeused.*7: ApplicableforDiaphragmmaterialcodeSandH.

Insideofisolatingdiaphragms(fillfluidside)aregoldplated,effectiveforhydrogenpermeation.*8: Hastelloy C-276 or N10276.*9: Gasketmaterialfortransmittersideis316LSSTwithPTFETefloncoating.*10: ApplicableforDiaphragmmaterialcodeT.*11: WhenselectingFlangeusagecodeH(forHightemperatureuse),Drain/ventareweldedtotheflange.*12: NotapplicableforDiaphragmmaterialcodeT.*13: NotapplicableforFlangeusagecodeH.*14: Totallength:119mm(standard:34mm);TotallengthwhencombiningwithoptioncodeK31andK35:130mm.The‘#’marksindicatetheconstructionmaterialsconformtoNACEmaterialrecommendationsperMR0175(2003).Pleaserefertolateststandardsfordetails.

Table4l. ProcesstemperatureandAmbienttemperature

Code Processtemperature*15

Ambienttemperature*17 Workingpressure Specific

gravity*18

Silicone oil*16 (high temp. and high vacuum use)

1 −10to250°C (14to482°F)

−10to50°C (14to122°F)

0.013kPaabs (0.0019psiabs)

toflangeratingpressure

1.07

Silicone oil*19*20 (high temp. and high vacuum use)

2 10to315°C (50to599°F)

10to50°C (50to122°F) 1.09

Silicone oil (high vacuum use) 4 −10to100°C

(14to212°F)−10to50°C (14to122°F) 1.07

Note: Thedifferentialpressuretransmittershouldbeinstalledatleast600mmbelowthehighpressure(HP)processconnection. However,thisvalue(600mm)maybeaffectedbyambienttemperature,operatingpressure,fillfluidormaterialofthewetted diaphragm. ContactYOKOGAWAwhenthetransmittercannotbeinstalledatleast600mmbelowtheHPprocessconnection.

*15: Seefigure1c,1d‘WorkingPressureandProcessTemperature.’*16: IncaseofdiaphragmmaterialcodeT(Tantalum),processtemperaturelimitisupto200°C(392°F).*17: Thisambienttemperatureisthetransmitterambienttemperature.*18: Approximatevaluesatatemperatureof25°C(77°F)*19: Fortheprocesswheretheprocesstemperatureexceeds250°C,specifyFlangeusagecode–H.*20: NotapplicableforDiaphragmmaterialcodeT.

Page 60: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

60

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Nov. 7, 2016-00

4.7 1/2-inch(15mm)/3/4-inch(20mm)/1-inch(25mm)Flangeconnectiontype,Raisedface(RF)Highvacuum/Hightemp.andhighvacuumuseCapillaryConnectionStyle:Backofdiaphragmsealunit F56E.ai

Model SuffixCodes DescriptionC81FD ............................................................................... Inner Diaphragm, Flange connection seal (Bundled capillary type)*2

C82FD ............................................................................... Inner Diaphragm, Flange connection seal (Standard type)Seal system location

-H........................................................................... Standardtypeforhighpressureside-L........................................................................... Standardtypeforlowpressureside-B........................................................................... Bundled capillary type (1 m separated)*4

Sealfillfluid ......................................................................... Refertotable4n.Transmitter connection type -S..................................................................... forgeneraluse

Capillary length*5

1.................................................................... 1 m*3 6..................... 6 m2.................................................................... 2 m 7..................... 7 m3.................................................................... 3 m 8..................... 8 m4.................................................................... 4 m 9..................... 9 m5.................................................................... 5 m A..................... 10 m

Capillary inside diameter 2................................................................. Capillary I.D. 2.03 mm

Capillary Style [Usage] [Sheath style]S.............................................................. forgeneraluse with PVC sheathV.............................................................. without PVC sheath*3

W............................................................. with PVC sheath red-colorCapillaryTubeConnection S............................................................ forgeneraluse

Inner Diaphragm Type -9........................................................ Inner Diaphragm Type-------- S...................................................... Always S-------- 2.................................................... Always 2Diaphragm material S................................................. 316LSST

H................................................. Hastelloy C-276*8

T................................................. Tantalum*16

Wetted Parts Material (ExceptforFlange)

S.............................................. 316LSSTH.............................................. Hastelloy C-276*8

T.............................................. TantalumDiaphragm diameter 6............................................ Diaphragm O.D: 2.4-inch (61 mm)Diaphragm option A......................................... Gold-plated diaphragm*7

N......................................... None-------- N...................................... Always NCapillary connection B................................... BackofdiaphragmsealunitFlangesize -6................................ 1/2-inch(15mm)

-7................................ 3/4-inch(20mm)-1................................ 1-inch (25 mm)

Flange standards J.............................. JISA.............................. ANSIP.............................. JPI

Flange pressure rating 1........................... class150 A............ 10K2........................... class300 B............ 20K4........................... class600 C............ 30K

D............ 40KSealing Face F......................... Raisedface(RF)Flat(noserration)

G......................... Raisedface(RF)WithSerration(ANSIB16.5)(forANSIflangeonly)

Page 61: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

61<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Sep. 27, 2018-00

Flange material (Flange, Pipe, Base, Vent plug, Vent screw)

C...................... 316 SST*6

S...................... 316LSST*6

Flange Usage -S.................. forgeneraluse*9

-P.................. forgeneraluse(Gasketmaterial:PTFETeflon)*10

-H.................. forhightemperatureuse*11*12

Vent Plug Style S................. forgeneraluse(withtwoventplugs)*13

L................. With two long vent plugs*14

N................. Without vent plug-------- N.............. Always N

Table4m.DiaphragmmaterialandSealingfacematerial

Wettedpartsmaterial*1 [Diaphragm material] [Sealingfacematerial]SS........................ [S]316LSST [S]316LSSTHH....................... [H] Hastelloy C-276*8# [H] Hastelloy C-276*8#TT........................ [T] Tantalum [T] Tantalum

*1: Usersmustconsiderthecharacteristicsofselectedwettedpartsmaterialandtheinfluenceofprocessfluids.Theuseofinappropriatematerialscanresultintheleakageofcorrosiveprocessfluidsandcauseinjurytopersonneland/ordamagetoplantfacilities.Itisalsopossiblethatthediaphragmitselfcanbedamagedandthatmaterialfromthebrokendiaphragmandthefillfluidcancontaminatetheuser’sprocessfluids. Beverycarefulwithhighlycorrosiveprocessfluidssuchashydrochloricacid,sulfuricacid,hydrogensulfide,sodiumhypochlorite,andhightemperaturesteam(150°C[302°F]orabove).ContactYokogawafordetailedinformationofthewetted parts material.

*2: Notapplicableforgaugetransmitteranddifferentialtransmitterwithsinglesealtype.*3: Incasewherecapillarylengthcode1(1m),themodelcodemustbeselectedforC82FD.NotapplicableforC81FD.*4: IncasewhereModelcodeF81FDisselected,ItmustbeSelectedsealsystemlocationcodeB.*5: Refertosection12forlimitationofcapillarylength.*6: Forgedversionofthematerialmaybeused.*7: ApplicableforDiaphragmmaterialcodeSandH.

Insideofisolatingdiaphragms(fillfluidside)aregoldplated,effectiveforhydrogenpermeation.*8: Hastelloy C-276 or N10276.*9: Gasketmaterialfortransmittersideis316LSSTwithPTFETefloncoating.*10: ApplicableforDiaphragmmaterialcodeT.*11: WhenselectingFlangeusagecodeH(forHightemperatureuse),Drain/ventareweldedtotheflange.*12: NotapplicableforDiaphragmmaterialcodeT.*13: NotapplicableforFlangeusagecodeH.*14: Totallength:119mm(standard:34mm);TotallengthwhencombiningwithoptioncodeK31andK35:130mm.The‘#’marksindicatetheconstructionmaterialsconformtoNACEmaterialrecommendationsperMR0175(2003).Pleaserefertolateststandardsfordetails.

Table4n. ProcesstemperatureandAmbienttemperature

Code Processtemperature*15

Ambienttemperature*17 Workingpressure Specific

gravity*18

Silicone oil*16 (high temp. and high vacuum use)

1 −10to250°C (14to482°F)

−10to50°C (14to122°F)

0.013kPaabs (0.0019psiabs)

toflangeratingpressure

1.07

Silicone oil*19*20 (high temp. and high vacuum use)

2 10to315°C (50to599°F)

10to50°C (50to122°F) 1.09

Silicone oil (high vacuum use) 4 −10to100°C

(14to212°F)−10to50°C (14to122°F) 1.07

Note: Thedifferentialpressuretransmittershouldbeinstalledatleast600mmbelowthehighpressure(HP)processconnection. However,thisvalue(600mm)maybeaffectedbyambienttemperature,operatingpressure,fillfluidormaterialofthewetted diaphragm. ContactYOKOGAWAwhenthetransmittercannotbeinstalledatleast600mmbelowtheHPprocessconnection.

*15: Seefigure1c,1d‘WorkingPressureandProcessTemperature.’*16: IncaseofdiaphragmmaterialcodeT(Tantalum),processtemperaturelimitisupto200°C(392°F).*17: Thisambienttemperatureisthetransmitterambienttemperature.*18: Approximatevaluesatatemperatureof25°C(77°F)*19: Fortheprocesswheretheprocesstemperatureexceeds250°C,specifyFlangeusagecode–H.*20: NotapplicableforDiaphragmmaterialcodeT.

Page 62: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

62

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Nov. 7, 2016-00

4.8 1/2-inch(15mm)/3/4-inch(20mm)/1-inch(25mm)Flangeconnectiontype,Ringtypejoint(RJ)Highvacuum/Hightemp.andhighvacuumuseCapillaryConnectionStyle:Backofdiaphragmsealunit F57E.ai

Model SuffixCodes DescriptionC81FD ............................................................................... Inner Diaphragm, Flange connection seal (Bundled capillary type)*2

C82FD ............................................................................... Inner Diaphragm, Flange connection seal (Standard type)Seal system location

-H........................................................................... Standardtypeforhighpressureside-L........................................................................... Standardtypeforlowpressureside-B........................................................................... Bundled capillary type (1 m separated)*4

Sealfillfluid ......................................................................... Refertotable4p.Transmitter connection type -S..................................................................... forgeneraluse

Capillary length*5

1.................................................................... 1 m*3 6..................... 6 m2.................................................................... 2 m 7..................... 7 m3.................................................................... 3 m 8..................... 8 m4.................................................................... 4 m 9..................... 9 m5.................................................................... 5 m A..................... 10 m

Capillary inside diameter 2................................................................. Capillary I.D. 2.03 mm

Capillary Style [Usage] [Sheath style]S.............................................................. forgeneraluse with PVC sheathV.............................................................. without PVC sheathW............................................................. with PVC sheath red-color

CapillaryTubeConnection S............................................................ forgeneraluse

Inner Diaphragm Type -9........................................................ Inner Diaphragm Type-------- S...................................................... Always S-------- 2.................................................... Always 2Diaphragm material S................................................. 316LSST

H................................................. Hastelloy C-276*8

T................................................. Tantalum*16

Wetted Parts Material (ExceptforFlange)

S.............................................. 316LSSTH.............................................. Hastelloy C-276*8

T.............................................. TantalumDiaphragm diameter 6............................................ Diaphragm O.D: 2.4-inch (61 mm)Diaphragm option A......................................... Gold-plated diaphragm*7

N......................................... None-------- N...................................... Always NCapillary connection B................................... BackofdiaphragmsealunitFlangesize -6................................ 1/2-inch(15mm)

-7................................ 3/4-inch(20mm)-1................................ 1-inch (25 mm)

Flange standards A.............................. ANSIP.............................. JPI

Flange pressure rating 2........................... class3004........................... class600

Sealing Face J......................... Ring type joint (RJ)Flange material (Flange, Pipe, Base, Vent plug, Vent screw)

C...................... 316 SST*6

S...................... 316LSST*6

Flange Usage -S.................. forgeneraluse*9

-P.................. forgeneraluse(Gasketmaterial:PTFETeflon)*10

-H.................. forhightemperatureuse*11*12

Vent Plug Style S................. forgeneraluse(withtwoventplugs)*13

L................. With two long vent plugs*14

N................. Without vent plug-------- N.............. Always N

Page 63: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

63<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Sep. 27, 2018-00

Table4o. DiaphragmmaterialandSealingfacematerial

Wettedpartsmaterial*1 [Diaphragm material] [Sealingfacematerial]SS........................ [S]316LSST [S]316LSSTHH....................... [H] Hastelloy C-276*8# [H] Hastelloy C-276*8#TT........................ [T] Tantalum [T] Tantalum

*1: Usersmustconsiderthecharacteristicsofselectedwettedpartsmaterialandtheinfluenceofprocessfluids.Theuseofinappropriatematerialscanresultintheleakageofcorrosiveprocessfluidsandcauseinjurytopersonneland/ordamagetoplantfacilities.Itisalsopossiblethatthediaphragmitselfcanbedamagedandthatmaterialfromthebrokendiaphragmandthefillfluidcancontaminatetheuser’sprocessfluids. Beverycarefulwithhighlycorrosiveprocessfluidssuchashydrochloricacid,sulfuricacid,hydrogensulfide,sodiumhypochlorite,andhightemperaturesteam(150°C[302°F]orabove).ContactYokogawafordetailedinformationofthewetted parts material.

*2: Notapplicableforgaugetransmitteranddifferentialtransmitterwithsinglesealtype.*3: Incasewherecapillarylengthcode1(1m),themodelcodemustbeselectedforC82FD.NotapplicableforC81FD.*4: IncasewhereModelcodeF81FDisselected,ItmustbeSelectedsealsystemlocationcodeB.*5: Refertosection12forlimitationofcapillarylength.*6: Forgedversionofthematerialmaybeused.*7: ApplicableforDiaphragmmaterialcodeSandH.

Insideofisolatingdiaphragms(fillfluidside)aregoldplated,effectiveforhydrogenpermeation.*8: Hastelloy C-276 or N10276.*9: Gasketmaterialfortransmittersideis316LSSTwithPTFETefloncoating.*10: ApplicableforDiaphragmmaterialcodeT.*11: WhenselectingFlangeusagecodeH(forHightemperatureuse),Drain/ventareweldedtotheflange.*12: NotapplicableforDiaphragmmaterialcodeT.*13: NotapplicableforFlangeusagecodeH.*14: Totallength:119mm(standard:34mm);TotallengthwhencombiningwithoptioncodeK31andK35:130mm.The‘#’marksindicatetheconstructionmaterialsconformtoNACEmaterialrecommendationsperMR0175(2003).Pleaserefertolateststandardsfordetails.

Table4p. ProcesstemperatureandAmbienttemperature

Code Processtemperature*15

Ambienttemperature*17 Workingpressure Specific

gravity*18

Silicone oil*16 (high temp. and high vacuum use)

1 −10to250°C (14to482°F)

−10to50°C (14to122°F)

0.013kPaabs (0.0019psiabs)

toflangeratingpressure

1.07

Silicone oil*19*20 (high temp. and high vacuum use)

2 10to315°C (50to599°F)

10to50°C (50to122°F) 1.09

Silicone oil (high vacuum use) 4 −10to100°C

(14to212°F)−10to50°C (14to122°F) 1.07

Note: Thedifferentialpressuretransmittershouldbeinstalledatleast600mmbelowthehighpressure(HP)processconnection. However,thisvalue(600mm)maybeaffectedbyambienttemperature,operatingpressure,fillfluidormaterialofthewetted diaphragm. ContactYOKOGAWAwhenthetransmittercannotbeinstalledatleast600mmbelowtheHPprocessconnection.

*15: Seefigure1c,1d‘WorkingPressureandProcessTemperature.’*16: IncaseofdiaphragmmaterialcodeT(Tantalum),processtemperaturelimitisupto200°C(392°F).*17: Thisambienttemperatureisthetransmitterambienttemperature.*18: Approximatevaluesatatemperatureof25°C(77°F)*19: Fortheprocesswheretheprocesstemperatureexceeds250°C,specifyFlangeusagecode–H.*20: NotapplicableforDiaphragmmaterialcodeT.

Page 64: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

64

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Sep. 27, 2018-00

5. DirectMountFlangedDiaphragmSeal(Flushtype)5.1 3-inch(80mm)/2-inch(50mm)Raisedface(RF)

F58E.ai

Model SuffixCodes DescriptionC20FW ............................................................................... Directmountflangeddiaphragmseal(Flushtype)Seal system location

-H........................................................................... forhighpressureside*2

-P........................................................................... forMasterside(Highpressureside)*3

-S........................................................................... forSlaveside(Lowpressureside)*3

Sealfillfluid ......................................................................... Refertotable5b.Transmitter connection type -S..................................................................... forgeneraluse

-------- N.................................................................... Always NCapillary inside diameter 2................................................................. Capillary I.D. 2.03 mm

-------- N.............................................................. Always NStay style S............................................................ forgeneraluse

L............................................................ forhightemperatureuse(longtype)*4

Process connection size*5

-3........................................................ 3-inch (80 mm)-2........................................................ 2-inch (50 mm)

Sealingface F...................................................... Raisedface(RF)Gasketcontactsurface 1.................................................... Serration (ANSI B16.5)

(forANSIflangewithsealingfacematerialCandS)2.................................................... Flat (no serration)

Diaphragm material*1 S................................................. 316LSST M....... MonelH................................................. Hastelloy C-276*9 K........ NickelT................................................. Tantalum*11 V........ 316LSSTU................................................. Titanium (Thickness: 0.0055 inch (0.14 mm))

J........ Hastelloy C-276*9

(Thickness: 0.006 inch (0.15 mm))Sealingfacematerial*1 S.............................................. 316LSST M....... Monel

H.............................................. Hastelloy C-276*9 K........ NickelT.............................................. Tantalum

Diaphragm diameter 9............................................ Diaphragm O.D: 3.54-inch (90 mm)6............................................ Diaphragm O.D: 2.4-inch (61 mm)

Diaphragm option A......................................... Gold-plated diaphragm*7

P......................................... With platinum plate*8

N......................................... None-------- N...................................... Always NCapillary connection B................................... Always BFlangesize*5 -3................................ 3-inch (80 mm)

-2................................ 2-inch (50 mm)Flange standards J.............................. JIS

A.............................. ANSIP.............................. JPID.............................. DIN

Flange pressure rating 1........................... class150 A............ 10K H........ PN10/162........................... class300 B............ 20K K........ PN25/404........................... class600 D............ 40K

Flange type S......................... forgeneraluseFlange material A...................... JIS S25C

B...................... 304 SST*6

C...................... 316 SST*6

S...................... 316LSST*6

Extended outside diameter -0.................. NoneExtended length 0................. None-------- N.............. Always N

Page 65: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

65<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Sep. 27, 2018-00

Table5a. DiaphragmmaterialandSealingfacematerial

Wettedpartsmaterial*1 [Diaphragm material] [Sealingfacematerial]Processconnectionsize 3-inch (80 mm)

SS........................ [S]316LSST [S]316LSSTHH....................... [H] Hastelloy C-276*9# [H] Hastelloy C-276*9#TT........................ [T] Tantalum [T] TantalumUU....................... [U] Titanium [U] TitaniumMM...................... [M] Monel [M] MonelKK....................... [K] Nickel [K] NickelVS........................ [V]316L [S]316LSST

(Thickness: 0.0055 inch (0.14 mm))JH........................ [J] Hastelloy C-276*9# [H] Hastelloy C-276*9#

(Thickness: 0.006 inch (0.15 mm))Processconnectionsize 2-inch (50 mm)

SS........................ [S]316LSST [S]316LSSTHS....................... [H] Hastelloy C-276*9# [S]316LSSTHC....................... [H] Hastelloy C-276*9# [C] 316 SSTHH....................... [H] Hastelloy C-276*9# [H] Hastelloy C-276*9#TT........................ [T] Tantalum [T] TantalumUU....................... [U] Titanium [U] TitaniumMM...................... [M] Monel [M] MonelKK....................... [K] Nickel [K] Nickel

*1: Usersmustconsiderthecharacteristicsofselectedwettedpartsmaterialandtheinfluenceofprocessfluids.Theuseofinappropriatematerialscanresultintheleakageofcorrosiveprocessfluidsandcauseinjurytopersonneland/ordamagetoplantfacilities.Itisalsopossiblethatthediaphragmitselfcanbedamagedandthatmaterialfromthebrokendiaphragmandthefillfluidcancontaminatetheuser’sprocessfluids. Beverycarefulwithhighlycorrosiveprocessfluidssuchashydrochloricacid,sulfuricacid,hydrogensulfide,sodiumhypochlorite,andhightemperaturesteam(150°C[302°F]orabove).ContactYokogawafordetailedinformationofthewetted parts material.

*2: ApplicableforEJXC50A,EJAC50E,EJXC80AandEJAC80E.*3: ApplicableforEJXC40A.*4: ApplicableforEJXC80AandEJAC80EwithSealfillfluidcodeA.*5: NotapplicabletodifferentsizebetweenProcessconnectionsizeandFlangesize.*6: Forgedversionofthematerialmaybeused.*7: ApplicableforDiaphragmmaterialcodeSandH.

Insideofisolatingdiaphragms(fillfluidside)aregoldplated,effectiveforhydrogenpermeation.*8: ApplicableforDiaphragmmaterialcodeT.*9: Hastelloy C-276 or N10276.The‘#’marksindicatetheconstructionmaterialsconformtoNACEmaterialrecommendationsperMR0175(2003).Pleaserefertolateststandardsfordetails.

Table5b. ProcesstemperatureandAmbienttemperature

Code Processtemperature*10

Ambienttemperature*13 Workingpressure Specific

gravity*14

Silicone oil*11 (general use) A −10to315°C

(14to599°F)−10to85°C (14to185°F) 2.7kPaabs(0.38psiabs)

toflangeratingpressure

1.07

Silicone oil*11*13 (general use) B −40to210°C

(−40to410°F)−40to85°C

(−40to185°F) 0.94

Silicone oil (low temperature use) F −70to100°C

(−94to212°F)−40to85°C

(−40to185°F)100kPaabs(atmosphericpressure)

toflangepressurerating 0.88

Fluorinated oil*12 (oil-prohibiteduse) D −20to120°C

(−4to248°F)−20to80°C (−4to176°F)

51kPaabs(7.4psiabs) toflangeratingpressure 1.90 to 1.92

Ethylene glycol (low temperature use) E −50to100°C

(−58to212°F)−40to85°C

(−40to185°F) 100kPaabs(atmosphericpressure) toflangepressurerating

1.09

Propylene glycol P −10to120°C (14to248°F)

−10to85°C (14to185°F) 1.04

*10: Seefigure1e,1f‘WorkingPressureandProcessTemperature.’*11: IncaseofdiaphragmmaterialcodeT(Tantalum),processtemperaturelimitisupto200°C(392°F).*12: EvenincasewherefillfluidcodeD(fluorinatedoil)isselected,ifdegreasecleansingtreatmentorbothdegreasecleansing

anddehydratingtreatmentforthewettedpartsisrequired,specifyoptioncodeK31orK35.*13: Thisambienttemperatureisthetransmitterambienttemperature.Seefigure1gand1h.*14: Approximatevaluesatatemperatureof25°C(77°F)

Page 66: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

66

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Sep. 27, 2018-00

5.2 11/2-inch(40mm)Raisedface(RF)

F59E.ai

Model SuffixCodes DescriptionC20FW ............................................................................... Directmountflangeddiaphragmseal(Flushtype)Seal system location

-H........................................................................... forhighpressureside*2

-P........................................................................... forMasterside(Highpressureside)*3

-S........................................................................... forSlaveside(Lowpressureside)*3

Sealfillfluid ......................................................................... Refertotable5d.Transmitter connection type -S..................................................................... forgeneraluse

-------- N.................................................................... Always NCapillary inside diameter 2................................................................. Capillary I.D. 2.03 mm

-------- N.............................................................. Always NStay style S............................................................ forgeneraluse

L............................................................ forhightemperatureuse(longtype)*4

Processconnectionsize -8........................................................ 11/2-inch(40mm)Sealingface F...................................................... Raisedface(RF)Gasketcontactsurface 2.................................................... Flat (no serration)Diaphragm material*1 S................................................. 316LSST

H................................................. Hastelloy C-276*7#Sealingfacematerial*1 S.............................................. 316LSST

H.............................................. Hastelloy C-276*7#Diaphragm diameter 6............................................ Diaphragm O.D: 2.4-inch (61 mm)Diaphragm option A......................................... Gold-plated diaphragm*6

N......................................... None-------- N...................................... Always NCapillary connection B................................... Always BFlangesize -8................................ 11/2-inch(40mm)Flange standards J.............................. JIS

A.............................. ANSIP.............................. JPI

Flange pressure rating 1........................... class150 A............ 10K2........................... class300 B............ 20K4........................... class600 D............ 40K

Flange type S......................... forgeneraluseFlange material A...................... JIS S25C

B...................... 304 SST*5

C...................... 316 SST*5

S...................... 316LSST*5

Extended outside diameter -0.................. NoneExtended length 0................. None-------- N.............. Always N

Note) 40A(11/2B)isareducertype.C10FR(Flushingconnectionring)isalwaysnecessarytobespecifiedwiththissize.

Page 67: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

67<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Sep. 27, 2018-00

Table5c. DiaphragmmaterialandSealingfacematerial

Wettedpartsmaterial*1 [Diaphragm material] [Sealingfacematerial]HS....................... [H] Hastelloy C-276*7# [S]316LSSTSS........................ [S]316LSST [S]316LSSTHH....................... [H] Hastelloy C-276*7# [H] Hastelloy C-276*7#

*1: Usersmustconsiderthecharacteristicsofselectedwettedpartsmaterialandtheinfluenceofprocessfluids.Theuseofinappropriatematerialscanresultintheleakageofcorrosiveprocessfluidsandcauseinjurytopersonneland/ordamagetoplantfacilities.Itisalsopossiblethatthediaphragmitselfcanbedamagedandthatmaterialfromthebrokendiaphragmandthefillfluidcancontaminatetheuser’sprocessfluids. Beverycarefulwithhighlycorrosiveprocessfluidssuchashydrochloricacid,sulfuricacid,hydrogensulfide,sodiumhypochlorite,andhightemperaturesteam(150°C[302°F]orabove).ContactYokogawafordetailedinformationofthewetted parts material.

*2: ApplicableforEJXC50A,EJAC50E,EJXC80AandEJAC80E.*3: ApplicableforEJXC40A.*4: ApplicableforEJXC80AandEJAC80EwithSealfillfluidcodeA.*5: Forgedversionofthematerialmaybeused.*6: Insideofisolatingdiaphragms(fillfluidside)aregoldplated,effectiveforhydrogenpermeation.*7: Hastelloy C-276 or N10276.The‘#’marksindicatetheconstructionmaterialsconformtoNACEmaterialrecommendationsperMR0175(2003).Pleaserefertolateststandardsfordetails.

Table5d. ProcesstemperatureandAmbienttemperature

Code Processtemperature*8

Ambienttemperature*10 Workingpressure Specific

gravity*11

Silicone oil*12 (general use) A −10to315°C

(14to599°F)−10to85°C (14to185°F) 2.7kPaabs(0.38psiabs)

toflangeratingpressure

1.07

Silicone oil*12 (general use) B −40to210°C

(−40to410°F)−40to85°C

(−40to185°F) 0.94

Silicone oil (low temperature use) F −70to100°C

(−94to212°F)−40to85°C

(−40to185°F)100kPaabs(atmosphericpressure)

toflangepressurerating 0.88

Fluorinated oil*9 (oil-prohibiteduse) D −20to120°C

(−4to248°F)−20to80°C (−4to176°F)

51kPaabs(7.4psiabs) toflangeratingpressure 1.90 to 1.92

Ethylene glycol (low temperature use) E −50to100°C

(−58to212°F)−40to85°C

(−40to185°F) 100kPaabs(atmosphericpressure) toflangepressurerating

1.09

Propylene glycol P −10to120°C (14to248°F)

−10to85°C (14to185°F) 1.04

*8: Seefigure1e,1f‘WorkingPressureandProcessTemperature.’*9: EvenincasewherefillfluidcodeD(fluorinatedoil)isselected,ifdegreasecleansingtreatmentorbothdegreasecleansing

anddehydratingtreatmentforthewettedpartsisrequired,specifyoptioncodeK31orK35.*10: Thisambienttemperatureisthetransmitterambienttemperature.Seefigure1gand1h.*11: Approximatevaluesatatemperatureof25°C(77°F)*12: Fortheprocesswheretheprocesstemperatureexceeds250°C,specifygasketusagecode–HofC10FRflushing

connection ring.

Page 68: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

68

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Nov. 7, 2016-00

6. DirectMountFlangedDiaphragmSeal(Extendedtype)6.1 4-inch(100mm)/3-inch(80mm)Raisedface(RF)

F60E.ai

Model SuffixCodes DescriptionC20FE ............................................................................... Directmountflangeddiaphragmseal(Extendedtype)Seal system location

-H........................................................................... forhighpressureside*2

-P........................................................................... forMasterside(Highpressureside)*3

-S........................................................................... forSlaveside(Lowpressureside)*3

Sealfillfluid ......................................................................... Refertotable6b.Transmitter connection type -S..................................................................... forgeneraluse

-------- N.................................................................... Always NCapillary inside diameter 2................................................................. Capillary I.D. 2.03 mm

-------- N.............................................................. Always NStay style S............................................................ forgeneraluse

L............................................................ forhightemperatureuse(longtype)*4

Process connection size*5

-4........................................................ 4-inch (100 mm)-3........................................................ 3-inch (80 mm)

Sealingface F...................................................... Raisedface(RF)Gasketcontactsurface 1.................................................... Serration (ANSI B16.5)

(forANSIflangewithsealingfacematerialCandS)2.................................................... Flat (no serration)

Diaphragm material*1 S................................................. 316LSST V........ 316LSSTH................................................. Hastelloy C-276*9 (Thickness: 0.0055 inch (0.14 mm))T................................................. Tantalum*11 J........ Hastelloy C-276*9

(Thickness: 0.006 inch (0.15 mm))Sealingfacematerial*1 (PIPE, BASE)

C.............................................. 316 SSTS.............................................. 316LSSTH.............................................. Hastelloy C-276*9

Diaphragm diameter 9............................................ Diaphragm O.D: 3.54-inch (90 mm)6............................................ Diaphragm O.D: 2.4-inch (61 mm)

Diaphragm option A......................................... Gold-plated diaphragm*7

P......................................... With platinum plate*8

N......................................... None-------- N...................................... Always NCapillary connection B................................... Always BFlangesize*5 -4................................ 4-inch (100 mm)

-3................................ 3-inch (80 mm)Flange standards J.............................. JIS

A.............................. ANSIP.............................. JPID.............................. DIN

Flange pressure rating 1........................... class150 A............ 10K H........ PN10/162........................... class300 B............ 20K K........ PN25/404........................... class600 D............ 40K

Flange type S......................... forgeneraluseFlange material A...................... JIS S25C

B...................... 304 SST*6

C...................... 316 SST*6

S...................... 316LSST*6

Extended outside diameter -4.................. 3.78±0.02 inch (96±0.5 mm)-3.................. 2.8±0.02 inch (71±0.5 mm)

Page 69: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

69<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Sep. 27, 2018-00

Extended length 2................. Length(X2)=1.97±0.02inch(50±0.5mm)4................. Length(X2)=3.94±0.02inch(100±0.5mm)6................. Length(X2)=5.91±0.02inch(150±0.5mm)8................. Length(X2)=7.87±0.03inch(200±0.8mm)

-------- N.............. Always N

Table6a. DiaphragmmaterialandSealingfacematerial

Wettedpartsmaterial*1 [Diaphragm material] [Sealingfacematerial]Processconnectionsize 4-inch (100 mm)

SC....................... [S]316LSST [C] 316 SST*10

SS........................ [S]316LSST [S]316LSSTHS....................... [H] Hastelloy C-276*9# [S]316LSSTHH....................... [H] Hastelloy C-276*9# [H] Hastelloy C-276*9#TS........................ [T] Tantalum [S]316LSSTVC....................... [V]316L [C] 316 SST*10

(Thickness: 0.0055 inch (0.14 mm))VS........................ [V]316L [S]316LSST

(Thickness: 0.0055 inch (0.14 mm))JC........................ [J] Hastelloy C-276*9# [C] 316 SST

(Thickness: 0.006 inch (0.15 mm))JS........................ [J] Hastelloy C-276*9# [S]316LSST

(Thickness: 0.006 inch (0.15 mm))JH........................ [J] Hastelloy C-276*9# [H] Hastelloy C-276*9#

(Thickness: 0.006 inch (0.15 mm))Processconnectionsize 3-inch (80 mm)

HC....................... [H] Hastelloy C-276*9# [C] 316 SST*10

SS........................ [S]316LSST [S]316LSSTHS....................... [H] Hastelloy C-276*9# [S]316LSSTHH....................... [H] Hastelloy C-276*9# [H] Hastelloy C-276*9#TS........................ [T] Tantalum [S]316LSST

*1: Usersmustconsiderthecharacteristicsofselectedwettedpartsmaterialandtheinfluenceofprocessfluids.Theuseofinappropriatematerialscanresultintheleakageofcorrosiveprocessfluidsandcauseinjurytopersonneland/ordamagetoplantfacilities.Itisalsopossiblethatthediaphragmitselfcanbedamagedandthatmaterialfromthebrokendiaphragmandthefillfluidcancontaminatetheuser’sprocessfluids. Beverycarefulwithhighlycorrosiveprocessfluidssuchashydrochloricacid,sulfuricacid,hydrogensulfide,sodiumhypochlorite,andhightemperaturesteam(150°C[302°F]orabove).ContactYokogawafordetailedinformationofthewetted parts material.

*2: ApplicableforEJXC50A,EJAC50E,EJXC80AandEJAC80E.*3: ApplicableforEJXC40A.*4: ApplicableforEJXC80AandEJAC80EwithSealfillfluidcodeA.*5: NotapplicabletodifferentsizebetweenProcessconnectionsizeandFlangesize.*6: Forgedversionofthematerialmaybeused.*7: ApplicableforDiaphragmmaterialcodeSandH.

Insideofisolatingdiaphragms(fillfluidside)aregoldplated,effectiveforhydrogenpermeation.*8: ApplicableforDiaphragmmaterialcodeT.*9: Hastelloy C-276 or N10276.*10: Pipeandbasematerialare316SST,Blockmaterialis316LSST.The‘#’marksindicatetheconstructionmaterialsconformtoNACEmaterialrecommendationsperMR0175(2003).Pleaserefertolateststandardsfordetails.

Page 70: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

70

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Sep. 27, 2018-00

Table6b. ProcesstemperatureandAmbienttemperature

Code Processtemperature*10

Ambienttemperature*13 Workingpressure Specific

gravity*14

Silicone oil*11 (general use) A −10to315°C

(14to599°F)−10to85°C (14to185°F) 2.7kPaabs(0.38psiabs)

toflangeratingpressure

1.07

Silicone oil*11*13 (general use) B −40to210°C

(−40to410°F)−40to85°C

(−40to185°F) 0.94

Silicone oil (low temperature use) F −70to100°C

(−94to212°F)−40to85°C

(−40to185°F)100kPaabs(atmosphericpressure)

toflangepressurerating 0.88

Fluorinated oil*12 (oil-prohibiteduse) D −20to120°C

(−4to248°F)−20to80°C (−4to176°F)

51kPaabs(7.4psiabs) toflangeratingpressure 1.90 to 1.92

Ethylene glycol (low temperature use) E −50to100°C

(−58to212°F)−40to85°C

(−40to185°F) 100kPaabs(atmosphericpressure) toflangepressurerating

1.09

Propylene glycol P −10to120°C (14to248°F)

−10to85°C (14to185°F) 1.04

*10: Seefigure1e,1f‘WorkingPressureandProcessTemperature.’*11: IncaseofdiaphragmmaterialcodeT(Tantalum),processtemperaturelimitisupto200°C(392°F).*12: EvenincasewherefillfluidcodeD(fluorinatedoil)isselected,ifdegreasecleansingtreatmentorbothdegreasecleansing

anddehydratingtreatmentforthewettedpartsisrequired,specifyoptioncodeK31orK35.*13: Thisambienttemperatureisthetransmitterambienttemperature.Seefigure1gand1h.*14: Approximatevaluesatatemperatureof25°C(77°F)

Page 71: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

71<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Sep. 27, 2018-00

7. RemotemountHygienicDiaphragmSeal7.1 ISO101.6/ISO76.1ClampFlushtype

F61.ai

Model SuffixCodes DescriptionC70SW ............................................................................... Remote Mount Hygienic Diaphragm Seal (Flush type)Seal system location

-H........................................................................... forhighpressureside-L........................................................................... forlowpressureside

Sealfillfluid ......................................................................... Refertotable7b.Transmitter connection type -S..................................................................... forgeneraluse

Capillary length*2 1................................................................ 1 m 6..................... 6 m2................................................................ 2 m 7..................... 7 m3................................................................ 3 m 8..................... 8 m4................................................................ 4 m 9..................... 9 m5................................................................ 5 m A..................... 10 m

Capillary inside diameter

2.............................................................. Capillary I.D. 2.03 mm1.............................................................. Capillary I.D. 1.3 mm*10

Capillary Style [Usage] [Sheath style]S........................................................ forgeneraluse with PVC sheathV........................................................ without PVC sheathW....................................................... with PVC sheath red-color

CapillaryTubeConnection S...................................................... forgeneraluse(Length:200mm)C...................................................... Shorttype(Length:100mm)

Process connection size

-3.................................................. ISO76.1-4.................................................. ISO101.6

Process Connection Style C................................................ Clamp connection-------- 2............................................. Always 2Diaphragm material S........................................... 316LSST

H........................................... Hastelloy C-276*3

Sealingfacematerial S........................................ 316LSSTDiaphragm diameter 9..................................... Diaphragm O.D: 3.54-inch (90 mm)

6..................................... Diaphragm O.D: 2.4-inch (61 mm)-------- N................................... Always NSealing Face Option E................................ Electro polishing*4

B................................ Buffing*5

C................................ Buffingandelectropolishing*4*5

N................................ NoneCapillary connection B............................. Always BAccessories*6

Clamp and GasketClampsize -3.......................... ISO76.1

-4.......................... ISO101.6-N.......................... None

Standards and Connection Style

C........................ ISOClampforFlushtype(Clamp Maximum Working Pressure: 1 MPa (145 psi))

N........................ None-------- N..................... Always NGasket material E................... EPDM(EthylenePropyleneRubber)

N................... None-------- N................ Always N

Extended Outside Diameter -0............ NoneExtendedLength 0........... None-------- N........ Always N

Page 72: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

72

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Sep. 27, 2018-00

Table7a. DiaphragmmaterialandSealingfacematerial

Wettedpartsmaterial*1 [Diaphragm material] [Sealingfacematerial]SS........................ [S]316LSST [S]316LSSTHS....................... [H] Hastelloy C-276*3# [S]316LSST

*1: Usersmustconsiderthecharacteristicsofselectedwettedpartsmaterialandtheinfluenceofprocessfluids.Theuseofinappropriatematerialscanresultintheleakageofcorrosiveprocessfluidsandcauseinjurytopersonneland/ordamagetoplantfacilities.Itisalsopossiblethatthediaphragmitselfcanbedamagedandthatmaterialfromthebrokendiaphragmandthefillfluidcancontaminatetheuser’sprocessfluids. Beverycarefulwithhighlycorrosiveprocessfluidssuchashydrochloricacid,sulfuricacid,hydrogensulfide,sodiumhypochlorite,andhightemperaturesteam(150°C[302°F]orabove).ContactYokogawafordetailedinformationofthewetted parts material.

*2: Refertosection12forlimitationofcapillarylength.*3: Hastelloy C-276 or N10276.*4: Electropolishingforallwettedparts(DiaphragmandBlock).*5: BuffingforBlockofwettedpartexceptdiaphragm.(JIS-standard:#400)*6: Clampandgasketarenotrequired,allofthecodeareselected“N”.The‘#’marksindicatetheconstructionmaterialsconformtoNACEmaterialrecommendationsperMR0175(2003).Pleaserefertolateststandardsfordetails.

Table7b. ProcesstemperatureandAmbienttemperature

Code Processtemperature*7

Ambienttemperature*8 Workingpressure Specific

gravity*9

Silicone oil (general use) B −10to120°C

(14to248°F)−10to60°C(14to140°F) 2.7kPaabs(0.38psiabs)to1MPaG 0.94

Propylene glycol P −10to120°C(14to248°F)

−10to60°C(14to140°F)

100kPaabs(atmosphericpressure)to1MPaG 1.04

*7: Seefigure1i‘WorkingPressureandProcessTemperature.’*8: Thisambienttemperatureisthetransmitterambienttemperature.*9: Approximatevaluesatatemperatureof25°C(77°F)*10: Applicableforprocessconnectionsizecode“3”withcapillarylengthmorethan6m.

Page 73: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

73<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Sep. 27, 2018-00

7.2 ISO51ClampFlushtype

F62.ai

Model SuffixCodes DescriptionC70SW ............................................................................... Remote Mount Hygienic Diaphragm Seal (Flush type)Seal system location

-H........................................................................... forhighpressureside-L........................................................................... forlowpressureside

Sealfillfluid ......................................................................... Refertotable7dTransmitter connection type -S..................................................................... forgeneraluse

Capillary length*2 1................................................................ 1 m2................................................................ 2 m3................................................................ 3 m4................................................................ 4 m5................................................................ 5 m

Capillary inside diameter 1.............................................................. Capillary I.D. 1.3 mm

Capillary Style [Usage] [Sheath style]S........................................................ forgeneraluse with PVC sheath V........................................................ without PVC sheathW....................................................... with PVC sheath red-color

CapillaryTubeConnection S...................................................... forgeneraluse(Length:200mm)C...................................................... Shorttype(Length:100mm)

Processconnectionsize -22................................................ ISO51Process Connection Style C................................................ Clamp connection-------- 2............................................. Always 2Diaphragm material S........................................... 316LSST

H........................................... Hastelloy C-276*3

Sealingfacematerial S........................................ 316LSSTDiaphragm diameter 4..................................... Diaphragm O.D: 1.57-inch (40 mm)-------- N................................... Always NSealing Face Option E................................ Electro polishing*4

B................................ Buffing*5

C................................ Buffingandelectropolishing*4*5

N................................ NoneCapillary connection B............................. Always BAccessories*6 Clamp and Gasket

Clampsize -2.......................... ISO51-N.......................... None

Standards and Connection Style

C........................ ISOClampforFlushtype(Clamp Maximum Working Pressure: 1 MPa (145 psi))

N........................ None-------- N..................... Always NGasket material E................... EPDM(EthylenePropyleneRubber)

N................... None-------- N................ Always N

Extended Outside Diameter -0............ NoneExtendedLength 0........... None-------- N........ Always N

Page 74: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

74

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Sep. 27, 2018-00

Table7c. DiaphragmmaterialandSealingfacematerial

Wettedpartsmaterial*1 [Diaphragm material] [Sealingfacematerial]SS........................ [S]316LSST [S]316LSSTHS....................... [H] Hastelloy C-276*3# [S]316LSST

*1: Usersmustconsiderthecharacteristicsofselectedwettedpartsmaterialandtheinfluenceofprocessfluids.Theuseofinappropriatematerialscanresultintheleakageofcorrosiveprocessfluidsandcauseinjurytopersonneland/ordamagetoplantfacilities.Itisalsopossiblethatthediaphragmitselfcanbedamagedandthatmaterialfromthebrokendiaphragmandthefillfluidcancontaminatetheuser’sprocessfluids. Beverycarefulwithhighlycorrosiveprocessfluidssuchashydrochloricacid,sulfuricacid,hydrogensulfide,sodiumhypochlorite,andhightemperaturesteam(150°C[302°F]orabove).ContactYokogawafordetailedinformationofthewetted parts material.

*2: Refertosection12forlimitationofcapillarylength.*3: Hastelloy C-276 or N10276.*4: Electropolishingforallwettedparts(DiaphragmandBlock).*5: BuffingforBlockofwettedpartexceptdiaphragm.(JIS-standard:#400)*6: Clampandgasketarenotrequired,allofthecodeareselected“N”.The‘#’marksindicatetheconstructionmaterialsconformtoNACEmaterialrecommendationsperMR0175(2003).Pleaserefertolateststandardsfordetails.

Table7d. ProcesstemperatureandAmbienttemperature

Code Processtemperature*7

Ambienttemperature*8 Workingpressure Specific

gravity*9

Silicone oil (general use) B −10to120°C

(14to248°F)−10to60°C (14to140°F) 2.7kPaabs(0.38psiabs)to1MPaG 0.94

Propylene glycol P −10to120°C (14to248°F)

−10to60°C (14to140°F)

100kPaabs(atmosphericpressure) to 1MPaG 1.04

*7: Seefigure1i‘WorkingPressureandProcessTemperature.’*8: Thisambienttemperatureisthetransmitterambienttemperature.*9: Approximatevaluesatatemperatureof25°C(77°F)

Page 75: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

75<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Sep. 27, 2018-00

7.3 ISO101.6/ISO76.1Clamptype

F63.ai

Model SuffixCodes DescriptionC70SE ............................................................................... Remote Mount Hygienic Diaphragm Seal (Extended type)Seal system location

-H........................................................................... forhighpressureside-L........................................................................... forlowpressureside

Sealfillfluid ......................................................................... Refertotable7f.Transmitter connection type -S...................................................................... forgeneraluse

Capillary length*2 1................................................................. 1 m 6...................... 6 m2................................................................. 2 m 7...................... 7 m3................................................................. 3 m 8...................... 8 m4................................................................. 4 m 9...................... 9 m5................................................................. 5 m A...................... 10 m

Capillary inside diameter

2.............................................................. Capillary I.D. 2.03 mm1.............................................................. Capillary I.D. 1.3 mm*10

Capillary Style [Usage] [Sheath style]S......................................................... forgeneraluse with PVC sheath V......................................................... without PVC sheathW........................................................ with PVC sheath red-color

CapillaryTubeConnection S...................................................... forgeneraluse(Length:200mm)C...................................................... Shorttype(Length:100mm)

Processconnectionsize -3.................................................. ISO76.1-4.................................................. ISO101.6

Process Connection Style C................................................ Clamp connection-------- 2.............................................. Always 2Process Connection Style S........................................... 316LSST

H........................................... Hastelloy C-276*3

Sealingfacematerial*11 S........................................ 316LSSTDiaphragm diameter 9...................................... Diaphragm O.D: 3.54-inch (90 mm)

6...................................... Diaphragm O.D: 2.4-inch (61 mm)-------- N................................... Always NSealing Face Option E................................ Electro polishing*4

B................................ Buffing*5

C................................ Buffingandelectropolishing*4*5

N................................ NoneCapillary connection B.............................. Always BAccessories*6

Clamp and GasketClampsize -3.......................... ISO76.1

-4.......................... ISO101.6-N.......................... None

Standards and Connection Style

D........................ ISOClampforExtendedtype(Clamp Maximum Working Pressure: 1 MPa (145 psi))

N........................ None-------- N...................... Always NGasket material E................... EPDM(EthylenePropyleneRubber)

N................... None-------- N................ Always N

Extended Outside Diameter -3............. 3.00 inch (76.1 mm)-4............. 4.00 inch (101.6 mm)

ExtendedLength 2........... Length(X2)=2.05inch(52mm)4........... Length(X2)=4.02inch(102mm)

-------- N........ Always N

Page 76: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

76

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Sep. 27, 2018-00

Table7e. DiaphragmmaterialandSealingfacematerial

Wettedpartsmaterial*1 [Diaphragm material] [Sealingfacematerial]*11

SS........................ [S]316LSST [S]316LSSTHS....................... [H] Hastelloy C-276*3# [S]316LSST

*1: Usersmustconsiderthecharacteristicsofselectedwettedpartsmaterialandtheinfluenceofprocessfluids.Theuseofinappropriatematerialscanresultintheleakageofcorrosiveprocessfluidsandcauseinjurytopersonneland/ordamagetoplantfacilities.Itisalsopossiblethatthediaphragmitselfcanbedamagedandthatmaterialfromthebrokendiaphragmandthefillfluidcancontaminatetheuser’sprocessfluids. Beverycarefulwithhighlycorrosiveprocessfluidssuchashydrochloricacid,sulfuricacid,hydrogensulfide,sodiumhypochlorite,andhightemperaturesteam(150°C[302°F]orabove).ContactYokogawafordetailedinformationofthewetted parts material.

*2: Refertosection12forlimitationofcapillarylength.*3: Hastelloy C-276 or N10276.*4: Electropolishingforallwettedparts(DiaphragmandBlock).*5: BuffingforBlockofwettedpartexceptdiaphragm.(JIS-standard:#400)*6: Clampandgasketarenotrequired,allofthecodeareselected“N”.The‘#’marksindicatetheconstructionmaterialsconformtoNACEmaterialrecommendationsperMR0175(2003).Pleaserefertolateststandardsfordetails.

Table7f. ProcesstemperatureandAmbienttemperature

Code Processtemperature*7

Ambienttemperature*8 Workingpressure Specific

gravity*9

Silicone oil (general use) B −10to120°C

(14to248°F)−10to60°C (14to140°F) 2.7kPaabs(0.38psiabs)to1MPaG 0.94

Propylene glycol P −10to120°C (14to248°F)

−10to60°C (14to140°F)

100kPaabs(atmosphericpressure) to 1MPaG 1.04

*7: Seefigure1i‘WorkingPressureandProcessTemperature.’*8: Thisambienttemperatureisthetransmitterambienttemperature.*9: Approximatevaluesatatemperatureof25°C(77°F)*10: Applicableforprocessconnectionsizecode“3”withcapillarylengthmorethan6m.*11: Pipe material (non-wetted parts): 316 SST

Page 77: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

77<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Sep. 27, 2018-00

8. DirectMountHygienicDiaphragmSeal8.1 ISO101.6/ISO76.1ClampFlushtype

Model SuffixCodes DescriptionC30SW ............................................................................... Direct Mount Hygienic Diaphragm Seal (Flush type)Seal system location

-H........................................................................... forhighpressureside*2

-P........................................................................... forMasterside(Highpressureside)*3

-S........................................................................... forSlaveside(Lowpressureside)*3

Sealfillfluid ......................................................................... Refertotable8b.Transmitter connection type -S..................................................................... forgeneraluse

-------- N.................................................................... Always NCapillary inside diameter 2................................................................. Capillary I.D. 2.03 mm

-------- N.............................................................. Always NStay style S............................................................ forgeneraluseProcess connection size

-3........................................................ ISO76.1-4........................................................ ISO101.6

Process Connection Style C...................................................... Clamp connection-------- 2.................................................... Always 2Diaphragm material S................................................. 316LSST

H................................................. Hastelloy C-276*4

Sealingfacematerial S.............................................. 316LSSTDiaphragm diameter 9............................................ Diaphragm O.D: 3.54-inch (90 mm)

6............................................ Diaphragm O.D: 2.4-inch (61 mm)-------- N......................................... Always NSealing Face Option E...................................... Electro polishing*5

B...................................... Buffing*6

C...................................... Buffingandelectropolishing*5*6

N...................................... NoneCapillary connection B................................... Always BAccessories*7 Clamp and Gasket

Clampsize -3................................ ISO76.1-4................................ ISO101.6-N................................ None

Standards and Connection Style

C.............................. ISOClampforFlushtype(Clamp Maximum Working Pressure: 1 MPa (145 psi))

N.............................. None-------- N........................... Always NGasket material E......................... EPDM(EthylenePropyleneRubber)

N......................... None-------- N...................... Always N

Extended Outside Diameter -0.................. NoneExtendedLength 0................. None-------- N.............. Always N

F64E.ai

Page 78: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

78

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Sep. 27, 2018-00

Table8a. DiaphragmmaterialandSealingfacematerial

Wettedpartsmaterial*1 [Diaphragm material] [Sealingfacematerial]SS........................ [S]316LSST [S]316LSSTHS....................... [H] Hastelloy C-276*4# [S]316LSST

*1: Usersmustconsiderthecharacteristicsofselectedwettedpartsmaterialandtheinfluenceofprocessfluids.Theuseofinappropriatematerialscanresultintheleakageofcorrosiveprocessfluidsandcauseinjurytopersonneland/ordamagetoplantfacilities.Itisalsopossiblethatthediaphragmitselfcanbedamagedandthatmaterialfromthebrokendiaphragmandthefillfluidcancontaminatetheuser’sprocessfluids. Beverycarefulwithhighlycorrosiveprocessfluidssuchashydrochloricacid,sulfuricacid,hydrogensulfide,sodiumhypochlorite,andhightemperaturesteam(150°C[302°F]orabove).ContactYokogawafordetailedinformationofthewetted parts material.

*2: ApplicableforEJXC80A,EJAC80E,EJXC50AandEJAC50E.*3: ApplicableforEJXC40A.*4: Hastelloy C-276 or N10276.*5: Electropolishingforallwettedparts(DiaphragmandBlock).*6: BuffingforBlockofwettedpartexceptdiaphragm.(JIS-standard:#400)*7: Clampandgasketarenotrequired,allofthecodeareselected“N”.The‘#’marksindicatetheconstructionmaterialsconformtoNACEmaterialrecommendationsperMR0175(2003).Pleaserefertolateststandardsfordetails.

Table8b. ProcesstemperatureandAmbienttemperature

Code Processtemperature*8

Ambienttemperature*9 Workingpressure Specific

gravity*10

Silicone oil (general use) B −10to120°C

(14to248°F)−10to60°C (14to140°F) 2.7kPaabs(0.38psiabs)to1MPaG 0.94

Propylene glycol P −10to120°C (14to248°F)

−10to60°C (14to140°F)

100kPaabs(atmosphericpressure) to 1MPaG 1.04

*8: Seefigure1i‘WorkingPressureandProcessTemperature.’*9: Thisambienttemperatureisthetransmitterambienttemperature.*10: Approximatevaluesatatemperatureof25°C(77°F)

Page 79: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

79<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Sep. 27, 2018-00

8.2 ISO51ClampFlushtype

Model SuffixCodes DescriptionC30SW ............................................................................... Direct Mount Hygienic Diaphragm Seal (Flush type)Seal system location -H........................................................................... forhighpressureside

Sealfillfluid ......................................................................... Refertotable8d.Transmitter connection type -S..................................................................... forgeneraluse

-------- N................................................................ Always NCapillary inside diameter 2.............................................................. Capillary I.D. 2.03 mm

-------- N........................................................ Always NStay style S...................................................... forgeneraluseProcessconnectionsize -2.................................................. ISO51Process Connection Style C................................................ Clamp connection-------- 2............................................. Always 2Diaphragm material S...........................................

H...........................................316LSSTHastelloy C-276*2

Sealingfacematerial S........................................ 316LSSTDiaphragm diameter 4..................................... Diaphragm O.D: 1.57-inch (40 mm)-------- N................................... Always NSealing Face Option E................................ Electro polishing*3

B................................ Buffing*4

C................................ Buffingandelectropolishing*3*4

N................................ NoneCapillary connection B............................. Always BAccessories*5

Clamp and GasketClampsize -2.......................... ISO51

-N.......................... NoneStandards and Connection Style

C........................ ISOClampforFlushtype(Clamp Maximum Working Pressure: 1 MPa (145 psi)) None

N........................ None-------- N..................... Always NGasket material E................... EPDM(EthylenePropyleneRubber)

N................... None-------- N................ Always N

Extended Outside Diameter -0............ NoneExtendedLength 0........... None-------- N........ Always N

F65.ai

Page 80: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

80

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Sep. 27, 2018-00

Table8c. DiaphragmmaterialandSealingfacematerial

Wettedpartsmaterial*1 [Diaphragm material] [Sealingfacematerial]SS........................ [S]316LSST [S]316LSSTHS....................... [H] Hastelloy C-276*2# [S]316LSST

*1: Usersmustconsiderthecharacteristicsofselectedwettedpartsmaterialandtheinfluenceofprocessfluids.Theuseofinappropriatematerialscanresultintheleakageofcorrosiveprocessfluidsandcauseinjurytopersonneland/ordamagetoplantfacilities.Itisalsopossiblethatthediaphragmitselfcanbedamagedandthatmaterialfromthebrokendiaphragmandthefillfluidcancontaminatetheuser’sprocessfluids. Beverycarefulwithhighlycorrosiveprocessfluidssuchashydrochloricacid,sulfuricacid,hydrogensulfide,sodiumhypochlorite,andhightemperaturesteam(150°C[302°F]orabove).ContactYokogawafordetailedinformationofthewetted parts material.

*2: Hastelloy C-276 or N10276.*3: Electropolishingforallwettedparts(DiaphragmandBlock).*4: BuffingforBlockofwettedpartexceptdiaphragm.(JIS-standard:#400)*5: Clampandgasketarenotrequired,allofthecodeareselected“N”.The‘#’marksindicatetheconstructionmaterialsconformtoNACEmaterialrecommendationsperMR0175(2003).Pleaserefertolateststandardsfordetails.

Table8d. ProcesstemperatureandAmbienttemperature

Code Processtemperature*6

Ambienttemperature*7 Workingpressure Specific

gravity*8

Silicone oil (general use) B −10to120°C

(14to248°F)−10to60°C (14to140°F) 2.7kPaabs(0.38psiabs)to1MPaG 0.94

Propylene glycol P −10to120°C (14to248°F)

−10to60°C (14to140°F)

100kPaabs(atmosphericpressure) to 1MPaG 1.04

*6: Seefigure1i‘WorkingPressureandProcessTemperature.’*7: Thisambienttemperatureisthetransmitterambienttemperature.*8: Approximatevaluesatatemperatureof25°C(77°F)

Page 81: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

81<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Sep. 27, 2018-00

8.3 ISO101.6/ISO76.1ClampExtendedtype

F66E.ai

Model SuffixCodes DescriptionC30SE ............................................................................... Direct Mount Hygienic Diaphragm Seal (Extended type)Seal system location

-H........................................................................... forhighpressureside*2

-P........................................................................... forMasterside(Highpressureside)*3

-S........................................................................... forSlaveside(Lowpressureside)*3

Sealfillfluid ......................................................................... Refertotable8f.Transmitter connection type -S..................................................................... forgeneraluse

-------- N.................................................................... Always NCapillary inside diameter 2................................................................. Capillary I.D. 2.03 mm

-------- N.............................................................. Always NStay style S............................................................ forgeneraluseProcess connection size

-3........................................................ ISO76.1-4........................................................ ISO101.6

Process Connection Style C...................................................... Clamp connection-------- 2.................................................... Always 2Diaphragm material S................................................. 316LSST

H................................................. Hastelloy C-276*4

Sealingfacematerial*8 S.............................................. 316LSSTDiaphragm diameter 9............................................ Diaphragm O.D: 3.54-inch (90 mm)

6............................................ Diaphragm O.D: 2.4-inch (61 mm)-------- N......................................... Always NSealing Face Option E...................................... Electro polishing*5

B...................................... Buffing*6

C...................................... Buffingandelectropolishing*5*6

N...................................... NoneCapillary connection B................................... Always BAccessories*7 Clamp and Gasket

Clampsize -3................................ ISO76.1-4................................ ISO101.6-N................................ None

Standards and Connection Style

D.............................. ISOClampforExtendedtype(Clamp Maximum Working Pressure: 1 MPa (145 psi))

N.............................. None-------- N........................... Always NGasket material E......................... EPDM(EthylenePropyleneRubber)

N......................... None-------- N...................... Always N

Extended Outside Diameter -3.................. 3.00 inch (76.1 mm)-4.................. 4.00 inch (101.6 mm)

ExtendedLength 2................. Length(X2)=2.05inch(52mm)4................. Length(X2)=4.02inch(102mm)

-------- N.............. Always N

Page 82: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

82

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Sep. 27, 2018-00

Table8e. DiaphragmmaterialandSealingfacematerial

Wettedpartsmaterial*1 [Diaphragm material] [Sealingfacematerial]*8

SS........................ [S]316LSST [S]316LSSTHS....................... [H] Hastelloy C-276*4# [S]316LSST

*1: Usersmustconsiderthecharacteristicsofselectedwettedpartsmaterialandtheinfluenceofprocessfluids.Theuseofinappropriatematerialscanresultintheleakageofcorrosiveprocessfluidsandcauseinjurytopersonneland/ordamagetoplantfacilities.Itisalsopossiblethatthediaphragmitselfcanbedamagedandthatmaterialfromthebrokendiaphragmandthefillfluidcancontaminatetheuser’sprocessfluids. Beverycarefulwithhighlycorrosiveprocessfluidssuchashydrochloricacid,sulfuricacid,hydrogensulfide,sodiumhypochlorite,andhightemperaturesteam(150°C[302°F]orabove).ContactYokogawafordetailedinformationofthewetted parts material.

*2: ApplicableforEJXC80A,EJAC80E,EJXC50AandEJAC50E.*3: ApplicableforEJXC40A.*4: Hastelloy C-276 or N10276.*5: Electropolishingforallwettedparts(DiaphragmandBlock).*6: BuffingforBlockofwettedpartexceptdiaphragm.(JIS-standard:#400)*7: Clampandgasketarenotrequired,allofthecodeareselected“N”.*8: Pipe material (non-wetted parts): 316 SST.The‘#’marksindicatetheconstructionmaterialsconformtoNACEmaterialrecommendationsperMR0175(2003).Pleaserefertolateststandardsfordetails.

Table8f. ProcesstemperatureandAmbienttemperature

Code Processtemperature*9

Ambienttemperature*10 Workingpressure Specific

gravity*11

Silicone oil (general use) B −10to120°C

(14to248°F)−10to60°C (14to140°F) 2.7kPaabs(0.38psiabs)to1MPaG 0.94

Propylene glycol P −10to120°C (14to248°F)

−10to60°C (14to140°F)

100kPaabs(atmosphericpressure) to 1MPaG 1.04

*9: Seefigure1i‘WorkingPressureandProcessTemperature.’*10: Thisambienttemperatureisthetransmitterambienttemperature.*11: Approximatevaluesatatemperatureof25°C(77°F)

Page 83: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

83<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Sep. 27, 2018-00

8.4 ISO51ClampExtendedtype

Model SuffixCodes DescriptionC30SE ............................................................................... Direct Mount Hygienic Diaphragm Seal (Extended type)Seal system location -H........................................................................... forhighpressureside

Sealfillfluid ......................................................................... Refertotable8h.Transmitter connection type -S..................................................................... forgeneraluse

-------- N................................................................ Always NCapillary inside diameter 2.............................................................. Capillary I.D. 2.03 mm

-------- N........................................................ Always NStay style S...................................................... forgeneraluseProcessconnectionsize -2.................................................. ISO51Process Connection Style C................................................ Clamp connection-------- 2............................................. Always 2Diaphragm material S........................................... 316LSST

H........................................... Hastelloy C-276*2

Sealingfacematerial*6 S........................................ 316LSSTDiaphragm diameter 2..................................... Diaphragm O.D: 1.57-inch (40 mm)-------- N................................... Always NSealing Face Option E................................ Electro polishing*3

B................................ Buffing*4

C................................ Buffingandelectropolishing*3*4

N................................ NoneCapillary connection B............................. Always BAccessories*5 Clamp and Gasket

Clampsize -2.......................... ISO51-N.......................... None

Standards and Connection Style

D........................ ISOClampforExtendedtype(Clamp Maximum Working Pressure: 1 MPa (145 psi))

N........................ None-------- N..................... Always NGasket material E................... EPDM(EthylenePropyleneRubber)

N................... None-------- N................ Always N

Extended Outside Diameter -2............ 2.00 inch (51 mm)ExtendedLength 2........... Length(X2)=2.05inch(52mm)

4........... Length(X2)=4.02inch(102mm)-------- N........ Always N

F67.ai

Page 84: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

84

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Sep. 27, 2018-00

Table8g. DiaphragmmaterialandSealingfacematerial

Wettedpartsmaterial*1 [Diaphragm material] [Sealingfacematerial]*6

SS........................ [S]316LSST [S]316LSSTHS....................... [H] Hastelloy C-276*2# [S]316LSST

*1: Usersmustconsiderthecharacteristicsofselectedwettedpartsmaterialandtheinfluenceofprocessfluids.Theuseofinappropriatematerialscanresultintheleakageofcorrosiveprocessfluidsandcauseinjurytopersonneland/ordamagetoplantfacilities.Itisalsopossiblethatthediaphragmitselfcanbedamagedandthatmaterialfromthebrokendiaphragmandthefillfluidcancontaminatetheuser’sprocessfluids. Beverycarefulwithhighlycorrosiveprocessfluidssuchashydrochloricacid,sulfuricacid,hydrogensulfide,sodiumhypochlorite,andhightemperaturesteam(150°C[302°F]orabove).ContactYokogawafordetailedinformationofthewetted parts material.

*2: Hastelloy C-276 or N10276.*3: Electropolishingforallwettedparts(DiaphragmandBlock).*4: BuffingforBlockofwettedpartexceptdiaphragm.(JIS-standard:#400)*5: Clampandgasketarenotrequired,allofthecodeareselected“N”.*6: Pipe material (non-wetted parts): 316 SST.The‘#’marksindicatetheconstructionmaterialsconformtoNACEmaterialrecommendationsperMR0175(2003).Pleaserefertolateststandardsfordetails.

Table8h. ProcesstemperatureandAmbienttemperature

Code Processtemperature*7

Ambienttemperature*8 Workingpressure Specific

gravity*9

Silicone oil (general use) B −10to120°C

(14to248°F)−10to60°C (14to140°F) 2.7kPaabs(0.38psiabs)to1MPaG 0.94

Propylene glycol P −10to120°C (14to248°F)

−10to60°C (14to140°F)

100kPaabs(atmosphericpressure) to 1MPaG 1.04

*7: Seefigure1i‘WorkingPressureandProcessTemperature.’*8: Thisambienttemperatureisthetransmitterambienttemperature.*9: Approximatevaluesatatemperatureof25°C(77°F)

Page 85: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

85<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Sep. 27, 2018-00

9. FlushingConnectionRing

F68E.ai

Model SuffixCodes DescriptionC10FR .............................................................................. Flushing connection ringSystem location

-H.......................................................................... forhighpressureside*3*4

-L.......................................................................... forLowpressureside*4

-P.......................................................................... forMasterside(Highpressureside)*5

-S.......................................................................... forSlaveside(Lowpressureside)*5

Structure S....................................................................... forflushtypeUsage -S................................................................. forgeneraluse

-H................................................................. forHightemperatureuse*1

(Processtemperature:250to315°C)-1................................................................. forHightemperatureandHighvacuumuse

(Processtemperature:-10to250°C)-2................................................................. forHightemperatureandHighvacuumuse*2*10

(Processtemperature:+10to315°C)-4................................................................. forHighvacuumuse

(Processtemperature:-10to100°C)Process connection size*6

3.............................................................. 3-inch (80 mm)2.............................................................. 2-inch (50 mm)8.............................................................. 11/2-inch(40mm)*9

Wetted parts material

C.......................................................... 316 SSTS.......................................................... 316LSSTH.......................................................... Hastelloy C-276*11

Flange standard J...................................................... JISA...................................................... ANSIP...................................................... JPID...................................................... DIN

Flange pressure rating 1.................................................. class150 A........ 10K H........ PN10/162.................................................. class300 B........ 20K K........ PN25/404.................................................. class600 C........ 30K L........ PN645.................................................. class 900 D........ 40K6.................................................. class 1500 E........ 63K

Sealingface F.............................................. Raisedface(RF)J.............................................. Ring type joint (RJ)*6*8

Gasketcontactsurface 1.......................................... Serration (ANSI B16.5)(forANSIflangewithwettedpartsmaterialCandS)

2.......................................... Flat (no serration)NumberofVentPlug(s) 2...................................... Twovent/drainPlugsVent Plug Screw Type 1.................................. WithR1/4VentPlug*13

3.................................. With1/4NPTVentPlugVent Plug Style L.............................. Longventplug-------- N.......................... Always NAccessories*7 Gasket

Gasket Usage -S..................... forgeneraluse-H..................... forHightemperatureuse*1*14

(Processtemperature:250to315°C)-N..................... None

GasketSize*6 3.................. 3-inch (80 mm)2.................. 2-inch (50 mm)8.................. 11/2-inch(40mm)N.................. None

Page 86: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

86

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Sep. 27, 2018-00

Accessories*7 Gasket

Gasket Material(Spiral Gasket)

[Hoop] [Filler]*12

C.............. 316 SST PTFETeflonS.............. 316LSST PTFETeflonH.............. Hastelloy C-276*11 PTFETeflonN.............. None

-------- N........... Always N

Table9a. CombinationforC10FRandC0FWdiaphragmmaterialcode

C10FRWettedpartsmaterialcode“C” “S” “H”

Diaphragmmaterialcode 316SST 316LSST HastelloyC-276S 316LSST H Hastelloy C-276*11# T Tantalum - - -U Titanium - - -M Monel - - -K Nickel - - -

V 316LSST (Thickness: 0.0055 inch (0.14 mm))

J Hastelloy C-276*11# (Thickness: 0.006 inch (0.15 mm))

:Applicable,-:Notapplicable

*1: WhenselectingGasketusagecodeH(forhightemperatureuse),drain/ventareweldedtothering.*2: WhenselectingGasketusagecode2(forhightemperatureandhighvacuumuse),drain/ventareweldedtothering.*3: ApplicableforEJXC81A,EJAC81E,EJXC50AandEJAC50E.*4: ApplicableforEJXC80AandEJAC80E.*5: ApplicableforEJXC40A.*6: NotapplicabletodifferentprocessconnectionsizebetweenC10FRandC0FW.*7: NotattachedGasket.Gasketcodeisalways“N”*8: IncasewheresealingfacecodeJ(Ringtypejoint),thegasketcontactsurfacecodemustbeselected2.*9: NotapplicableforsealingfacecodeJ(Ringtypejoint).*10: NotapplicableforWettedpartsmaterialcodeH.*11: Hastelloy C-276 or ASTM N10276*12: WhenspecifiedusagecodeH,fillermaterialisInorganictype.*13: Notapplicableforgasketcontactsurfacecode1.*14: Notapplicableforoptionalcode/K31and/K35.

Page 87: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

87<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Sep. 27, 2018-00

10.TankSpudModel SuffixCodes Description

TS ............................................................................. Tank SpudExtended Length(L)

-E......................................................................... 2inch(50mm)forISO101.6Clamp-F......................................................................... 4inch(100mm)forISO101.6Clamp-J......................................................................... 2inch(50mm)forISO76.1Clamp-K......................................................................... 4inch(100mm)forISO76.1Clamp-G........................................................................ 2inch(50mm)forISO51Clamp-H......................................................................... 4inch(100mm)forISO51Clamp

Material U...................................................................... 304 SSTV...................................................................... 316 SSTW..................................................................... 316LSST

Plate thickness A.................................................................. 0.63 inch (16 mm) forISO101.6ClamporISO76.1 ClampB.................................................................. 0.47 inch (12 mm)

C.................................................................. 0.32 inch (8 mm)D.................................................................. 0.63 inch (16 mm) forISO51ClampE.................................................................. 0.47 inch (12 mm)F.................................................................. 0.32 inch (8 mm)

Unit: mm (approx. inch)

F69E.ai

Detail of X• With a groove to avoid welding distortion Welding Part Plate Thickness Code: A, B or C

• No groove to avoid welding distortion Welding Part Plate Thickness Code: D, E or F

L*1

30° 30°

30° 30°

18°

X

ø5(ø0.2)

øD ød

A B C

D E F

18°

18° 35°

*1: L is 50 mm (2 inch) or 100 mm (4 inch).

5(0.2)16

(0.63)12

(0.47)

5(0.2)

16(0.63)

16(0.63)

8(0.31)

5(0.2)16

(0.63)12

(0.47)

5(0.2)

16(0.63)

16(0.63)

8(0.31)

16(0.63)

øD ød

ISO101.6 Clamp 7.87 inch (200 mm)

4.69 inch (119 mm)

ISO76.1 Clamp 5.91 inch (150 mm)

3.58 inch (91 mm)

ISO51 Clamp 4.33 inch (110 mm)

2.52 inch (64 mm)

Page 88: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

88

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Nov. 20, 2019-00

11.OPTIONALSPECIFICATIONS EJXC80A,EJAC80EDiaphragmSealSystem

EJXC81A,EJAC81EAbsolutePressureDiaphragmSealSystem

Item Description CodeOperating temperature correction*6 Adjustingrange:80°CtoMaximumtemperatureofspecifiedfillfluid R

Oil-prohibiteduse Degrease cleansing treatment K21Oil-prohibitedusewith dehydrating treatment Degrease cleansing and dehydrating treatment K25

Materialcertificate [Lowpressureside]Processconnector M1C[High pressure side] Process connector M2C

Pressuretest/ Leaktest certificate*1

[Flange rating] [Test pressure]For Differential pressure transmitter

JIS 10K 2 MPa (290 psi) T51JIS 20K 5 MPa (720 psi) T54JIS 30K 8 MPa (1160 psi) T56JIS 40K 10 MPa (1450 psi) T57JIS 63K 16 MPa (2300 psi) T58

Nitrogen (N2) Gas*2 Retention time: one minute

JIS 30K, 40K 7 MPa (1000 psi)*4 T55ANSI/JPIclass150 3 MPa (430 psi) T52ANSI/JPIclass300 8 MPa (1160 psi) T56ANSI/JPIclass600,900,1500 16 MPa (2300 psi) T58ANSI/JPIclass300,600,900,1500 7 MPa (1000 psi)*4 T55DINPN10/16 3 MPa (430 psi) T52DINPN25/40 7 MPa (1000 psi) T55DIN PN64 10 MPa (1450 psi) T57

For Gauge/absolute pressure transmitter

For A-Capsule

JIS 10K 2 MPa (290 psi) T51JIS 20K, 30K, 40K, 63K 3.5 MPa (720 psi) T53ANSI/JPIclass150 3 MPa (430 psi) T52ANSI/JPIclass300,600,900,1500 3.5 MPa (720 psi) T53DINPN10/16 3 MPa (430 psi) T52DINPN25/40,PN64 3.5 MPa (720 psi) T53

For B-Capsule

JIS 10K 2 MPa (290 psi) T51JIS 20K 5 MPa (720 psi) T54JIS 30K 8 MPa (1160 psi) T56JIS 40K 10 MPa (1450 psi) T57JIS 63K 16 MPa (2300 psi) T58JIS 30K, 40K 7 MPa (1000 psi)*4 T55ANSI/JPIclass150 3 MPa (430 psi) T52ANSI/JPIclass300 8 MPa (1160 psi) T56ANSI/JPIclass600,900,1500 16 MPa (2300 psi) T58ANSI/JPIclass300,600,900,1500 7 MPa (1000 psi)*4 T55DINPN10/16 3 MPa (430 psi) T52DINPN25/40 7 MPa (1000 psi) T55DIN PN64 10 MPa (1450 psi) T57

AbsolutepressuretransmitterForM-Capsule 50 kPa (200 inH2O) T04

Page 89: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

89<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Nov. 7, 2016-00

EJXC40ADigitalRemoteSensoredDiaphragmSealSystem

Item Description CodeDRSCable Cablelength15m EC1

Cablelength30m EC3Cablelength45m EC5

Oil-prohibiteduse Degrease cleansing treatment K21Oil-prohibitedusewith dehydrating treatment Degrease cleansing and dehydrating treatment K25

Pressuretest/ Leaktest certificate*1*7

[Flange rating] [Test pressure]For A-Capsule

JIS 10K, 20K, 40K200 kPa (29 psi) T72ANSI/JPIClass150,300,600

DINPN10/16,PN25/40For B-Capsule

JIS 10K, 20K, 40K2 MPa (290 psi) T51Nitrogen (N2) Gas*2

Retention time: one minute

ANSI/JPIClass150,300,600DINPN10/16,PN25/40

For C-Capsule

JIS 10K 2 MPa (290 psi) T51JIS 20K 5 MPa (720 psi) T54JIS 40K 10 MPa (1450 psi) T57JIS 40K 7 MPa (1000 psi)*5 T55ANSI/JPIClass150 3 MPa (430 psi) T52ANSI/JPIClass300 8 MPa (1160 psi) T56ANSI/JPIClass600 10 MPa (1450 psi) T57ANSI/JPIClass300,600 7 MPa (1000 psi)*5 T55DINPN10/16 3MPa(430 psi) T52DINPN25/40 7MPa(1000 psi) T55

EJXC50A,EJAC50EDirectMountedDiaphragmSealSystem

Item Description CodeOil-prohibiteduse Degrease cleansing treatment K21Oil-prohibitedusewith dehydrating treatment Degrease cleansing and dehydrating treatment K25

Pressuretest/ Leaktest certificate*1

[Flange rating] [Test pressure]For A-Capsule

JIS 10K, 20K, 40K200 kPa (29 psi) T72ANSI/JPIClass150,300,600

DINPN10/16,PN25/40For B-Capsule

JIS 10K, 20K, 40K2 MPa (290 psi) T51Nitrogen (N2) Gas*2

Retention time: one minute

ANSI/JPIClass150,300,600DINPN10/16,PN25/40

For C-Capsule

JIS 10K 2 MPa (290 psi) T51JIS 20K 5 MPa (720 psi) T54JIS 40K 10 MPa (1450 psi) T57JIS 40K 7 MPa (1000 psi)*3 T55ANSI/JPIClass150 3 MPa (430 psi) T52ANSI/JPIClass300 8 MPa (1160 psi) T56ANSI/JPIClass600 10 MPa (1450 psi) T57ANSI/JPIClass300,600 7 MPa (1000 psi)*3 T55DINPN10/16 3MPa(430 psi) T52DINPN25/40 7MPa(1000 psi) T55

Page 90: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

90

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Nov. 20, 2019-00

*1: TheunitonthecertificateisalwaysParegardlessofselectionofoptioncodeD1,D3,orD4.*2: Drynitrogengasisusedforoil-prohibiteduse(optioncodeK21andK25).*3: Applicableforextendedtype(ModelcodeC20FE).*4: ApplicablewhenC80FEorC20FE(extendedtypediaphragmseal)isspecifiedwitheither/bothhighandlowpressureside

on transmitters.*5: ApplicablewhenC20FE(extendedtypediaphragmseal)isspecifiedwitheither/bothmaster(highpressureside)andslave

(low pressure side) on transmitters.*6: Specifytheprocessoperatingtemperatureforzerocorrection.Example:Zerocorrectionbyprocesstemperature90°C.*7: Whencombinationtype(ScrewandFlange)isselected,applyflangesidepressurevaluetotestcertificate.

C80FW,C80FEFlangedDiaphragmSeal

Item Description CodeOil-prohibiteduse Degrease cleansing treatment K31Oil-prohibitedusewith dehydrating treatment Degrease cleansing and dehydrating treatment K35

Materialcertificate For Flush type (C80FW)

Processflange,Block MCWProcessflange,Block,Diaphragm MDWFlange, Block, Diaphragm, Seal ring*11, Capillary MHW

For Extended type (C80FE)

Processflange,Block,Pipe,Base MCEProcessflange,Block,Pipe,Base,Diaphragm MDEFlange, Block, Pipe, Base, Diaphragm, Seal ring*11, Capillary MHE

Teflonfilm*8*9*10 (ApplicableforC80FW)

DiaphragmprotectionfromstickyprocessfluidbyFEPTeflonfilmattachedwithfluorinatedoil.Operationrange:20to150°C,0to2MPa(Notapplicableforvacuumservice). TF1

C81FA,C81FDInnerDiaphragmtypeFlangedDiaphragmSeal(Bundledcapillarytype)

Item Description CodeOil-prohibiteduse Degrease cleansing treatment K31Oil-prohibitedusewith dehydrating treatment Degrease cleansing and dehydrating treatment K35

Materialcertificate For C81FA Adapter connection type

Adapter (Flange), Block MCBAdapter (Flange), Block, Diaphragm MDBAdapter(Flange),Block,BoltforBlock, Studboltandnut MLB

Adapter(Flange),Block,BoltforBlock, Studboltandnut,Diaphragm MMB

Adaptor,Block,Boltforblock,Studboltandnut,Diaphragm,Capillary,Seal ring, Vent and Draing plug, Vent screw*12 MSB

For C81FD Flange connection type

Flange, Base, Block, Pipe MCFFlange, Base, Block, Pipe, Diaphragm MDFFlange,Base,Block,Pipe,Boltforblock MLFFlange,Base,Block,Pipe,Boltforblock,Diaphragm MMFFlange,Base,Block,Pipe,Boltforblock,Diaphragm,Capillary,Sealring, Vent and Drain plug, Vent screw*12 MSF

Page 91: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

91<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Nov. 20, 2019-00

C82FA,C82FDInnerDiaphragmtypeFlangedDiaphragmSeal(Standardtype)

Item Description CodeOil-prohibiteduse Degrease cleansing treatment K31Oil-prohibitedusewith dehydrating treatment Degrease cleansing and dehydrating treatment K35

Materialcertificate For C82FA Adapter connection type

Adapter (Flange), Block MCAAdapter (Flange), Block, Diaphragm MDAAdapter(Flange),Block,BoltforBlock, Studboltandnut MLA

Adapter(Flange),Block,BoltforBlock, Studboltandnut,Diaphragm MMA

Adaptor,Block,Boltforblock,Studboltandnut,Diaphragm,Capillary,Seal ring, Vent and Draing plug, Vent screw*12 MSA

For C82FD Flange connection type

Flange, Base, Block, Pipe MCDFlange, Base, Block, Pipe, Diaphragm MDDFlange,Base,Block,Pipe,Boltforblock MLDFlange,Base,Block,Pipe,Boltforblock,Diaphragm MMDFlange,Base,Block,Pipe,Boltforblock,Diaphragm,Capillary,Sealring, Vent and Drain plug, Vent screw*12 MSD

C20FW,C20FEDirectMountFlangedDiaphragmSeal

Item Description CodeOil-prohibiteduse Degrease cleansing treatment K31Oil-prohibitedusewith dehydrating treatment Degrease cleansing and dehydrating treatment K35

Materialcertificate For Flush type (C20FW)

Processflange,Block MCWProcessflange,Block,Diaphragm MDWFlange, Block, Diaphragm, Seal ring*11, Capillary MHW

For Extended type (C20FE)

Processflange,Block,Pipe,Base MCEProcessflange,Block,Pipe,Base,Diaphragm MDEFlange, Block, Pipe, Base, Diaphragm, Seal ring*11, Capillary MHE

Teflonfilm*8 (ApplicableforC20FW)

DiaphragmprotectionfromstickyprocessfluidbyFEPTeflonfilmattachedwithfluorinatedoil.Operationrange:20to150°C,0to2MPa(Notapplicableforvacuumservice). TF1

C30SW,C30SEDirectMountHygienicDiaphragmSeal

Item Description CodeOil-prohibiteduse Degrease cleansing treatment K31

Degreasecleansingtreatmentandcertificate K81Materialcertificate For

Flush type (C30SW)Block MPWBlock, Diaphragm MQW

For Extended type (C30SE)

Block MPEBlock, Diaphragm MQE

Certificate Electro polishing Y1Buffing Y2BuffingandElectropolishing Y4

Page 92: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

92

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Nov. 20, 2019-00

C10FRFlushingconnectionring

Item Description CodeOil-prohibiteduse Degrease cleansing treatment K31Oil-prohibitedusewith dehydrating treatment Degrease cleansing and dehydrating treatment K35

MaterialcertificateRing M0RRing, Vent and drain plug, Vent screw M1R

*8: NotapplicableforcombinationwithC10FR(Flushingconnectionring).*9: NotapplicableforHighvacuumuse(fillfluidcode:1,2,4)*10: NotapplicableforAbsolutepressurediaphragmsealsystem(Modecode:EJXC81AandEJAC81E)*11: NotapplicablefordiaphragmmaterialcodeT.*12: DrainandventplugisnotapplicableforventplugstylecodeN.

Page 93: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

93<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Nov. 20, 2019-00

12.PERFORMANCESPECIFICATIONSSpecificationConformanceEJXandEJA-Eseriesensuresspecificationconformancetoatleast±3σ.

12.1 EJXC80ADiaphragmSealSystemZero-basedcalibratedspan,linearoutput,diaphragmmaterialcodeSfordiaphragmdiametercode9,fillfluidcodeB.andcapillarylengthof5m.ForFieldbusandPROFIBUSPAcommunicationtypes,usecalibratedrangeinsteadofspaninthefollowingspecifications.

ApplicableProducts(Transmitter):EJX110A(Differentialpressuretransmitter)withbothsidediaphragmsealEJX110A(Differentialpressuretransmitter)withCompensatingcapillarytype

Measurementspan M H V

Reference accuracy

X≤span ±0.15%ofSpan ±0.15%ofSpan

X > span ±(0.02+0.013URL/span)% ofSpan

±(0.085+0.013URL/span)% ofSpan

±(0.085+0.0065URL/span)% ofSpan

AmbientTemperatureEffectsper28°C (50°F)Change ±(0.25%Span+0.06%URL)

StaticPressureEffectsper0.69MPa (100 psi) Change

SpanEffects:±0.02%ofspanEffectonZero:±0.014%ofURL

ApplicableProducts(Transmitter):EJX110A(Differentialpressuretransmitter)withone-sidediaphragmsealEJX110A(Differentialpressuretransmitter)withcombinationsealtypeDirectmountwithremotesealtype

Measurementspan M H V

Reference accuracy

X≤span ±0.15%ofSpan ±0.15%ofSpan

X > span ±(0.02+0.013URL/span)%ofSpan

±(0.085+0.013URL/span)%ofSpan

±(0.085+0.0065URL/span)%ofSpan

AmbientTemperatureEffectsper28°C(50°F)Change ±(0.5%Span+0.12%URL)

StaticPressureEffectsper 0.69 MPa (100 psi) Change

SpanEffects:±0.04%ofspanEffectonZero:±0.028%ofURL

SquareRootOutputAccuracyThesquarerootaccuracyisapercentofflowspan Measurementspan M H V

Output AccuracyX 10 kPa

(40 inH2O)100 kPa

(400 inH2O)1.4 MPa (200 psi)50% or Greater Sameasreferenceaccuracy

50% to Dropout pointReferenceaccuracy×50 URL

(upper range limit)100 kPa

(400 inH2O)500 kPa

(2000 inH2O)14 MPa

(2000 psi)Squarerootoutput(%)

ApplicableProducts(Transmitter):EJX430A(gaugepressuretransmitter)withRemotediaphragmseal

Measurementspan A,B Measurementspan A BReference accuracy

X≤span ±0.15%ofSpanX 0.35 MPa

(50 psi)1.6 MPa (230 psi)X > span ±(0.1+0.005URL/span)%ofSpan

AmbientTemperatureEffectsper28°C(50°F)Change ±(0.5%Span+0.025%URL) URL

(upper range limit)3.5 MPa (500 psi)

16 MPa (2300 psi)

ApplicableProducts(Transmitter):EJX310A(Absolutepressuretransmitter)withC80FDiaphragmseal

Measurementspan M A,BReference accuracy

X≤span ±0.15%ofSpan ±0.15%ofSpanX > span ±(0.02+0.0214URL/span)%ofSpan ±(0.1+0.005URL/span)%ofSpan

AmbientTemperatureEffectsper28°C(50°F)Change ±(0.5%Span+0.025%URL) ±(0.5%Span+0.025%URL)

Measurementspan M A B

X 21.4kPaabs(6.3inHgabs)

0.35kPaabs(50 psia)

1.6MPaabs(230 psia)

URL (upper range limit)

130kPaabs(38.4inHgabs)

3.5MPaabs(500 psia)

16MPaabs(2300 psia)

Page 94: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

94

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Nov. 20, 2019-00

12.2 EJXC80ADirectMountedDiaphragmSealSystemZero-basedcalibratedspan,linearoutput,diaphragmmaterialcodeSfordiaphragmdiametercode9,fillfluidcodeB.and C20F on High side Seal.ForFieldbusandPROFIBUSPAcommunicationtypes,usecalibratedrangeinsteadofspaninthefollowingspecifications.

ApplicableProducts(Transmitter):EJX110A(Differentialpressuretransmitter)withC20FDirectmountseal

Measurementspan M H V

Reference accuracy

X≤span ±0.075%ofSpan ±0.075%ofSpan

X > span ±(0.025+0.005URL/span)%ofSpan

±(0.025+0.01URL/span)%ofSpan

±(0.025+0.005URL/span)%ofSpan

AmbientTemperatureEffectsper28°C(50°F)Change

±(0.224%Span+0.056%URL) ±(0.14%Span+0.028%URL)

StaticPressureEffectsper 0.69 MPa (100 psi) Change

SpanEffects:±0.028%ofspanEffectonZero:±0.007%ofURL

SquareRootOutputAccuracyThesquarerootaccuracyisapercentofflowspan. Measurementspan M H V

Output AccuracyX 10 kPa

(40 inH2O)100 kPa

(400 inH2O)1.4 MPa (200 psi)50% or Greater Sameasreferenceaccuracy

50% to Dropout pointReferenceaccuracy×50 URL

(upper range limit)100 kPa

(400 inH2O)500 kPa

(2000 inH2O)14 MPa

(2000 psi)Squarerootoutput(%

12.3 EJXC50APerformancespecificationsZero-basedcalibratedspan,linearoutput,diaphragmmaterialcodeSfordiaphragmdiametercode9,fillfluidcodeB.ForFieldbusandPROFIBUSPAcommunicationtypes,usecalibratedrangeinsteadofspaninthefollowingspecifications.

Measurementspan A,B,C Measurementspan A B CReference accuracy

X≤span ±0.055%ofSpanX 20 kPa

(2.9 psi)0.2 MPa (29 psi)

1 MPa (145 psi)X > span ±(0.01+0.0045URL/span)%ofSpan

AmbientTemperatureEffectsper28°C(50°F)Change ±(0.14%Span+0.028%URL) URL

(upper range limit)200 kPa (29 psi)

2 MPa (290 psi)

10 MPa (1450 psi)

12.4 EJXC40A PerformancespecificationsZero-basedcalibratedspan,linearoutput,diaphragmmaterialcodeSfordiaphragmdiametercode9,fillfluidcodeB.DifferentialpressureaccuracyofDRSsystem

Measurementspan A,B,C

Referenceaccuracy ± Accuracyofmaster2+Accuracyofslave2

Example: ± 0.0552+0.0552=±0.078%(Incaseof“X≤span”)*Masterandslaveaccuracy:RefertoEJXC50A

Page 95: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

95<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Nov. 20, 2019-00

12.5 EJAC80EDiaphragmSealSystemPerformancespecificationsZero-basedcalibratedspan,linearoutput,diaphragmmaterialcodeSfordiaphragmdiametercode9,fillfluidcodeB.andcapillarylengthof5m.ForFieldbusandPROFIBUSPAcommunicationtypes,usecalibratedrangeinsteadofspaninthefollowingspecifications.

ApplicableProducts(Transmitter):EJA110E(Differentialpressuretransmitter)withbothsideC80Fdiaphragmseal

Measurementspan M,H VReference accuracy

X≤span ±0.2%ofSpan ±0.2%ofSpanX > span ±(0.15+0.01URL/span)%ofSpan ±(0.15+0.005URL/span)%ofSpan

AmbientTemperatureEffectsper28°C(50°F)Change ±(0.48%Span+0.06%URL)

StaticPressureEffectsper 0.69 MPa (100 psi) Change

SpanEffects:±0.02%ofspanEffectonZero:±0.014%ofURL

ApplicableProducts(Transmitter):EJA110E(Differentialpressuretransmitter)withboth-sidediaphragmsealEJA110E(Differentialpressuretransmitter)withcombinationdiaphragmsealDirectmountwithremotesealtype

Measurementspan M,H VReference accuracy

X≤span ±0.2%ofSpan ±0.2%ofSpanX > span ±(0.15+0.01URL/span)%ofSpan ±(0.15+0.005URL/span)%ofSpan

AmbientTemperatureEffectsper28°C(50°F)Change ±(0.96%Span+0.12%URL)

StaticPressureEffectsper 0.69 MPa (100 psi) Change

SpanEffects:±0.04%ofspanEffectonZero:±0.028%ofURL

SquareRootOutputAccuracyThesquarerootaccuracyisapercentofflowspan. Measurementspan M H V

Output AccuracyX 20 kPa

(80 inH2O)100 kPa

(400 inH2O)1.4 MPa (200 psi)50% or Greater Sameasreferenceaccuracy

50% to Dropout pointReferenceaccuracy×50 URL

(upper range limit)100 kPa

(400 inH2O)500 kPa

(2000 inH2O)14 MPa

(2000 psi)Squarerootoutput(%

ApplicableProducts(Transmitter):EJA430E(Gaugepressuretransmitter)withRemotediaphragmseal

Measurementspan A,B Measurementspan A BReference accuracy

X≤span ±0.2%ofSpanX 0.35 MPa

(50 psi)1.6 MPa (230 psi)X > span ±(0.16+0.004URL/span)%ofSpan

AmbientTemperatureEffectsper28°C(50°F)Change ±(0.53%Span+0.025%URL) URL

(upper range limit)3.5 MPa (500 psi)

16 MPa (2300 psi)

ApplicableProducts(Transmitter):EJA310E(Absolutepressuretransmitter)withC80FDiaphragmseal

Measurementspan M A,BReference accuracy

X≤span ±0.2%ofSpan ±0.2%ofSpanX > span ±(0.15+0.0083URL/span)%ofSpan ±(0.16+0.004URL/span)%ofSpan

AmbientTemperatureEffectsper28°C(50°F)Change ±(0.96%Span+0.12%URL) ±(0.53%Span+0.025%URL)

Measurementspan M A B

X 21.4kPaabs(6.3inHgabs)

0.35kPaabs(50 psia)

1.6MPaabs(230 psia)

URL (upper range limit)

130kPaabs(38.4inHgabs)

3.5MPaabs(500 psia)

16MPaabs(2300 psia)

Page 96: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

96

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Nov. 20, 2019-00

12.6 EJAC80EDirectMountedDiaphragmSealSystemPerformancespecificationsZero-basedcalibratedspan,linearoutput,diaphragmmaterialcodeSfordiaphragmdiametercode9,fillfluidcodeB.and C20F on High side Seal.ForFieldbusandPROFIBUSPAcommunicationtypes,usecalibratedrangeinsteadofspaninthefollowingspecifications.

ApplicableProducts(Transmitter):EJA110E(Differentialpressuretransmitter)withC20FDirectmountseal

Measurementspan M H V

Reference accuracy

X≤span ±0.075%ofSpan ±0.075%ofSpan

X > span ±(0.025+0.005URL/span)%ofSpan

±(0.025+0.01URL/span)%ofSpan

±(0.025+0.005URL/span)%ofSpan

AmbientTemperatureEffectsper28°C(50°F)Change

±(0.224%Span+0.056%URL) ±(0.14%Span+0.028%URL)

StaticPressureEffectsper 0.69 MPa (100 psi) Change

SpanEffects:±0.028%ofspanEffectonZero:±0.007%ofURL

SquareRootOutputAccuracyThesquarerootaccuracyisapercentofflowspan. Measurementspan M H V

Output AccuracyX 10 kPa

(40 inH2O)100 kPa

(400 inH2O)1.4 MPa (200 psi)50% or Greater Sameasreferenceaccuracy

50% to Dropout pointReferenceaccuracy×50 URL

(upper range limit)100 kPa

(400 inH2O)500 kPa

(2000 inH2O)14 MPa

(2000 psi)Squarerootoutput(%

12.7 EJAC50EPerformancespecificationsZero-basedcalibratedspan,linearoutput,diaphragmmaterialcodeSfordiaphragmdiametercode9,fillfluidcodeB.ForFieldbusandPROFIBUSPAcommunicationtypes,usecalibratedrangeinsteadofspaninthefollowingspecifications.

Measurementspan A,B,C Measurementspan A B C

Reference accuracy

X≤span ±0.075%ofSpanX 20 kPa

(2.9 psi)0.2 MPa (29 psi)

1 MPa (145 psi)X > span ±(0.0075URL/span)%ofSpan

AmbientTemperatureEffectsper28°C(50°F)Change ±(0.14%Span+0.028%URL) URL

(upper range limit)200 kPa (29 psi)

2 MPa (290 psi)

10 MPa (1450 psi)

Page 97: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

97<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Nov. 20, 2019-00

13.CapillarylengthlimitationDiaphragmsealsystem Diaphragm

diameterCode

DiaphragmmaterialCode

CapillaryLengthHigh-side Low-side 1to5m 6to10m 11to13m 14to15m

DifferentialPressure Transmitter

Both side (HighandLow) Diaphragm seal

C80F C80F 9

S

6

C81F 6 C82F C82F C80F C80F 9

H, T, U, M, K

C81F 6 ---- ----

C82F C82F ---- ----

C80F C80F 9 V ---- ----6 ---- ---- ----

C80F C80F 9 J ---- ----

C70S C70S9

S,H ---- ----

6 ---- ----4 ---- ---- ----

High side Direct mount seal Lowside Diaphragm seal

C20F C80F9 S

H, T, U, M, K

---- ----

6 ---- ----

C30S C70S 9 S,H ---- ----6 ---- ----

Compensating capillary type C20F C80F

9S

H, T, U, M, K

---- ----

6S

H, T, U, M, K

---- ----

Gauge Pressure Transmitter

High side Diaphragm seal

C80F ---- 9S

---- ----6 ---- ----

C82F ---- 6 ---- ----

C80F ---- 9H, T, U,

M, K

---- ----6 ---- ----

C82F ---- 6 ---- ----

C70S ----9

S,H ---- ----

6 ---- ----4 ---- ---- ----

LowsideDiaphragmseal

---- C80F 9S

---- ----6 ---- ----

---- C82F 6 ---- ----

---- C80F 9H, T, U,

M, K

---- ----6 ---- ----

---- C82F 6 ---- ----

---- C70S9

S,H ---- ----

6 ---- ----4 ---- ---- ----

High side Diaphragm seal

(LowsideOpentoatmosphere)

C80F ---- 9S

6 ----

C82F ---- 6 ----

C80F ---- 9H, T, U,

M, K

6 ---- ----

C82F ---- 6 ---- ----

C80F ---- 9 V ---- ----6 ---- ---- ----

C80F ---- 9 J ---- ----

C70S ----9

S,H ---- ----

6 ---- ----4 ---- ---- ----

AbsolutePressure Transmitter

High side Diaphragm seal

C80F ---- 9S

6 ----

C82F ---- 6 ----

C80F ---- 9H,T

6 ---- ----

C82F ---- 6 ---- ----:applicable----:notapplicable

Page 98: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

98

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Nov. 20, 2019-00

DIMENSIONS(DifferentialPressure,TransmitterPart) RemoteMountedDiaphragmSealSystem,RemoteSealforHighandLowPressureSide[TransmitterPart:EJX110A,EJA110EDifferentialPressureTransmitter] Unit: mm (approx. inch)

F70E.ai

Integral indicator(optional)

Conduit connection

Zero adjustment

Mounting bracket(flat-type, optional)

Ground terminal

Low pressure sideHigh pressure side

54(2.13)

6(0.24)

Electrical connectionfor code 5, 9, A, and D.

315(

12.4

0)

175(

6.89

)

137(5.39)

95(3.74)

47(1

.85)

124(

4.88

)

83(3.27)

89(3.50)

ø70

(2.7

6)

129(

5.08

)

39(1.54)

ø78(

3.07

)

12(0.47)

110(4.33)External indicatorconduit connection(optional)

2-inch pipe(O.D. 60.5 mm)

Terminal side

*1:Whenelectricalconnectioncode7orCisselected,ablindplugisprotrudedupto8mmfromtheconduitconnection.

RemoteMountedDiaphragmSealSystem,RemoteSealforHighorLowPressureSide(ThefigurebelowshowstheEJC80-D80.IncaseoftheEJC80-D08,processconnectionofhighandlowpressure sides are reversed.)

[TransmitterPart:EJX110A,EJA110EDifferentialPressureTransmitter] Unit: mm (approx. inch)

F71E.ai

315(

12.4

0)

175(

6.89

)

67(2.64)

95(3.74)

47(1

.85)

124(

4.88

)

115(4.53)

89(3.50)

ø70

(2.7

6)

129(

5.08

)39

(1.54)

ø78(

3.07

)

12(0.47)

110(4.33)

41(1.61)

Integral indicator(optional)Conduit connection

Zero adjustment

Mounting bracket(flat-type, optional)

Ground terminal

Low pressure sideHigh pressure side

Electrical connectionfor code 5, 9, A, and D.

External indicatorconduit connection(optional)

2-inch pipe(O.D. 60.5 mm)

Terminal side

27(1.06)

65*1

(2.56)

Vent plug

Drain plug

54(2.13)

6(0.24)

Process connector(optional)

Process connection

*1:Whenelectricalconnectioncode7orCisselected,ablindplugisprotrudedupto8mmfromtheconduitconnection.

Page 99: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

99<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Nov. 20, 2019-00

DirectMountedDiaphragmSealSystem Unit: mm (approx. inch)

54(2.13)

6(0.24)

Electrical connectionfor code 5, 9, A, and D.

*1: When Option code K11, K12, K15, or K16 is selected, add 15 mm(0.59 inch) to the value in the flange.*2: When electrical connection code 7 or C is selected, a blind plug is protruded upto 8 mm from the conduit connection.

38*1

(1.50)54

(2.13)

129

(5.0

8)

ø70

(2.7

6)

ø78(

3.07

)

110(4.33)

39(1.54)

12(0.47)

95(3.74)

41(1.61)

67(2.64)

175(

6.89

)14

5(5.

71)

Ground terminal

Zero adjustmentConduit connection

Integral indicator(optional)

External indicatorconduit connection(optional)

Vent plug

Low pressure sideprocess connection

Drain plugProcess connection

Process connector(optional)

F72E.ai

DiaphragmSealSystem,CombinationofDirectMountandRemoteMountFlangedDiaphragmSeal

[TransmitterPart:EJX110A,EJA110EDifferentialPressureTransmitter] Unit: mm (approx. inch)

F73E.ai

54(2.13)6

(0.24)

Integral indicator(optional)Conduit connection Zero adjustment Ground terminal

Electrical connectionfor code 5, 9, A, and D.

175(

6.89

)

95(3.74)

145(

5.71

) ø70

(2.7

6)

129(

5.08

)

39(1.54)

ø78(

3.07

)

12(0.47)

110(4.33)

External indicatorconduit connection(optional)

41(1.61)

Diaphragm seal capilary

*1: When electrical connection code 7 or C is selected, a blind plug is protruded up to 8 mm from the conduit connection.

Page 100: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

100

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Nov. 20, 2019-00

DiaphragmSealSystem,CombinationofDirectMountandRemoteMountFlangedDiaphragmSeal,withcompensatingcapillaryforHighPressureSide

[TransmitterPart:EJX110A,EJA110EDifferentialPressureTransmitter] Unit: mm (approx. inch)

F74E.ai

Integral indicator(optional)

Conduit connectionZero adjustment Ground terminal

Electrical connectionfor code 5, 9, A, and D.

175(

6.89

)

95(3.74)14

5(5.

71) ø70

(2.7

6)

129(

5.08

)

39(1.54)

ø78(

3.07

)

12(0.47)

110(4.33)External indicatorconduit connection(optional)

41(1.61)

Diaphragm seal capilary

*1: When electrical connection code 7 or C is selected, a blind plug is protruded up to 8 mm from the conduit connection.

Correction capilary

54(2.13)6

(0.24)

Approx. 465(18.31)

Page 101: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

101<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Nov. 20, 2019-00

DIMENSIONS(GaugePressure,TransmitterPart) RemoteMountedDiaphragmSealSystem[TransmitterPart:EJX430A,EJA430EGaugePressureTransmitter] Unit: mm (approx. inch)

F75E.ai

54(2.13)

6(0.24)

Electrical connectionfor code 5, 9, A, and D.

315(

12.4

0)

175(

6.89

)

137(5.39)

95(3.74)

47(1

.85)

124(

4.88

)

83(3.27)

89(3.50)

ø70

(2.7

6)

129(

5.08

)

39(1.54)

ø78(

3.07

)

12(0.47)

110(4.33)External indicatorconduit connection(optional)

Integral indicator(optional)

Conduit connection

Zero adjustment

Mounting bracket(flat-type, optional) 2-inch pipe

(O.D. 60.5 mm)

Ground terminal

Low pressure side

High pressure side

ø5(0.2)

Open to atmosphere

Terminal side

*2:Whenelectricalconnectioncode7orCisselected,ablindplugisprotrudedupto8mmfromtheconduitconnection.

Page 102: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

102

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Nov. 20, 2019-00

DIMENSIONS(AbsolutePressure,TransmitterPart) RemoteMountedAbsolutePressureDiaphragmSealSystem[TransmitterPart:EJX310A,EJA310EAbsolutePressureTransmitter] Unit: mm (approx. inch)

F76E.ai

54

6

315(

12.4

0) 175(

6.89

)

137(5.39)

95(3.74)

47(1

.85)

124(

4.88

)

83(3.27)

89(3.50)

ø70

(2.7

6)12

9(5.

08)

39(1.54)

ø78(

3.07

)

12(0.47)

110(4.33)External indicatorconduit connection(optional)

54(2.13)

6(0.24)

Electrical connectionfor code 5, 9, A, and D.

Mounting bracket(flat-type, optional)

Integral indicator(optional)

Conduit connection

2-inch pipe(O.D. 60.5 mm)

Zero adjustment Ground terminal

*1: When electrical connection code 7 or C is selected, a blind plug is protruded up to 8 mm from the conduit connection.

Page 103: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

103<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Nov. 20, 2019-00

DirectMountedDiaphragmSealSystem[TransmitterPart:EJX530A,EJA530EProcessConnectionCodeP]Forthetransmitterpartofdigitalremotesensoreddiaphragmsealsystem,refertoGS01C25W05-01EN.

Unit: mm (approx. inch)

F77E.ai

95(3.74)

(optional)

Extenal indicatorConduit connection

Integral indicator(optional)

12(0.47)

110(4.33)

39(1.54)

ø70

(2.7

6)

ø78(

3.07

)

Conduit connection

Zeroadjustment

Ground terminal

Open toatmosphere

169(

6.65

)

Electrical connectioncode 5, 9, A, and D.

54(2.13)6

(0.24)

SUPPLY

CHECKor

ALARM

+–+–

Power supply and output terminals

External indicator (ammeter) terminals*1*2

orStatus contact output terminals*2

(when /AL is specified)

Terminal Wiring

*1: When using an external indicator or check meter, the internal resistance must be 10 Ω or less. A check meter or indicator cannot be connected when /AL option is specified. *2: Not available for FOUNDATION Fieldbus and PROFIBUS PA communication types.

+–

Terminal Configuration

Ground terminal

1Terminal

12

23

23

2Terminal 3Terminal

TERMINALS

*1: When electrical connection code 7 or C is selected, a blind plug is protruded upto 8 mm from the conduit connection.

Page 104: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

104

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Nov. 20, 2019-00

DIMENSIONS(DiaphragmSealPartandAccessories) C80FWRemoteMountFlangedDiaphragmSeal(FlashType)[RaisedFace(RF),CapillaryConnectedtotheSideofDiaphragmSealUnit]

Unit: mm (approx. inch)

F78E.aiøgøCøD

n-øh

ød*1

Capillarylength

*1: Indicates inside diameter of gasket contact surface.

n-øhøgøCøD

t T

f

t T

f

High pressure side: compensating capillary

Low pressure side: diaphragm seal capillary

With compensating capillary

Processflangesize:3-inch(80mm)FlangeStandardCode

FlangeRatingCode FlangeRating øD øC

Boltholest f*2 T*4 øg ødNo.(n) Dia.(øh)

J A JIS 10K 185(7.28) 150(5.91) 8 19(0.75) 18(0.71) 0 25(0.98) 130(5.12) 90(3.54)J B JIS 20K 200(7.87) 160(6.30) 8 23(0.91) 22(0.87) 0 25(0.98) 130(5.12) 90(3.54)J C JIS 30K 210(8.27) 170(6.69) 8 23(0.91) 28(1.10) 0 25(0.98) 130(5.12) 90(3.54)J D JIS 40K 210(8.27) 170(6.69) 8 23(0.91) 32(1.26) 0 25(0.98) 130(5.12) 90(3.54)J E JIS 63K 230(9.06) 185(7.28) 8 25(0.98) 40(1.57) 0 25(0.98) 130(5.12) 90(3.54)A 1 ANSI Class 150 190.5(7.50) 152.4(6.00) 4 19.1(0.75) 23.9(0.94) 1.6(0.06) 25(0.98) 130(5.12) 90(3.54)A 2 ANSI Class 300 209.6(8.25) 168.1(6.62) 8 22.4(0.88) 28.5(1.12) 1.6(0.06) 25(0.98) 130(5.12) 90(3.54)A 4 ANSI Class 600 209.6(8.25) 168.1(6.62) 8 22.4(0.88) 38.2(1.50) 6.4(0.25) 25(0.98) 130(5.12) 90(3.54)A 5 ANSI Class 900 241.3(9.50) 190.5(7.50) 8 25.4(1.00) 38.1(1.50) 0 25(0.98) 130(5.12) 90(3.54)A 6 ANSI Class 1500 266.7(10.50) 203.2(8.00) 8 31.8(1.25) 47.8(1.88) 0 25(0.98) 130(5.12) 90(3.54)P 1 JPI Class 150 190(7.48) 152.4(6.00) 4 19(0.75) 24(0.94) 1.6(0.06) 25(0.98) 130(5.12) 90(3.54)P 2 JPI Class 300 210(8.27) 168.1(6.62) 8 22(0.87) 28.5(1.12) 1.6(0.06) 25(0.98) 130(5.12) 90(3.54)P 4 JPI Class 600 210(8.27) 168.1(6.62) 8 22(0.87) 38.4(1.51) 6.4(0.25) 25(0.98) 130(5.12) 90(3.54)P 5 JPI Class 900 241(9.49) 190.5(7.50) 8 26(1.02) 38.5(1.52) 0 25(0.98) 130(5.12) 90(3.54)P 6 JPI Class 1500 267(10.51) 203.2(8.00) 8 32(1.26) 48(1.89) 0 25(0.98) 130(5.12) 90(3.54)D H DINPN10/16 200(7.87) 160(6.30) 8 18(0.71) 20(0.79) 0 25(0.98) 130(5.12) 90(3.54)D K DINPN25/40 200(7.87) 160(6.30) 8 18(0.71) 24(0.94) 0 25(0.98) 130(5.12) 90(3.54)D L DIN PN 64 215(8.46) 170(6.69) 8 22(0.87) 28(1.10) 0 25(0.98) 130(5.12) 90(3.54)

Page 105: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

105<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Nov. 20, 2019-00

Unit: mm (approx. inch)

Processflangesize:2-inch(50mm)FlangeStandardCode

FlangeRatingCode FlangeRating øD øC

Boltholest f*2 T*4 øg ødNo.(n) Dia.(øh)

J A JIS 10K 155(6.10) 120(4.72) 4 19(0.75) 16(0.63) 0 25(0.98) 100(3.94) 61(2.40)J B JIS 20K 155(6.10) 120(4.72) 8 19(0.75) 18(0.71) 0 25(0.98) 100(3.94) 61(2.40)J C JIS 30K 165(6.50) 130(5.12) 8 19(0.75) 22(0.87) 0 25(0.98) 100(3.94) 61(2.40)J D JIS 40K 165(6.50) 130(5.12) 8 19(0.75) 26(1.02) 0 25(0.98) 100(3.94) 61(2.40)J E JIS 63K 185(7.28) 145(5.71) 8 23(0.91) 34(1.34) 0 25(0.98) 100(3.94) 61(2.40)A 1 ANSI Class 150 152.4(6.00) 120.7(4.75) 4 19.1(0.75) 19.1(0.75) 1.6(0.06) 25(0.98) 100(3.94) 61(2.40)A 2 ANSI Class 300 165.1(6.50) 127(5.00) 8 19.1(0.75) 22.4(0.88) 1.6(0.06) 25(0.98) 100(3.94) 61(2.40)A 4 ANSI Class 600 165.1(6.50) 127(5.00) 8 19.1(0.75) 31.8(1.25) 6.4(0.25) 25(0.98) 100(3.94) 61(2.40)P 1 JPI Class 150 152(5.98) 120.6(4.75) 4 19(0.75) 19.5(0.77) 1.6(0.06) 25(0.98) 100(3.94) 61(2.40)P 2 JPI Class 300 165(6.50) 127(5.00) 8 19(0.75) 22.5(0.89) 1.6(0.06) 25(0.98) 100(3.94) 61(2.40)P 4 JPI Class 600 165(6.50) 127(5.00) 8 19(0.75) 31.9(1.26) 6.4(0.25) 25(0.98) 100(3.94) 61(2.40)D H DINPN10/16 165(6.50) 125(4.92) 4 18(0.71) 18(0.71) 0 25(0.98) 100(3.94) 61(2.40)D K DINPN25/40 165(6.50) 125(4.92) 4 18(0.71) 20(0.79) 0 25(0.98) 100(3.94) 61(2.40)D L DIN PN 64 180(7.09) 135(5.31) 4 22(0.87) 26(1.02) 0 25(0.98) 100(3.94) 61(2.40)

Processflangesize:1.5-inch(40mm)FlangeStandardCode

FlangeRatingCode FlangeRating øD øC

Boltholest f*2 T øg ødNo.(n) Dia.(øh)

J A JIS 10K 140(5.51) 105(4.13) 4 19(0.75) 16(0.63) 0 27(1.06) 86(3.39) *3J B JIS 20K 140(5.51) 105(4.13) 4 19(0.75) 18(0.71) 0 27(1.06) 86(3.39) *3J C JIS 30K 160(6.30) 120(4.72) 4 23(0.91) 22(0.87) 0 27(1.06) 86(3.39) *3J D JIS 40K 160(6.30) 120(4.72) 4 23(0.91) 24(0.94) 0 27(1.06) 86(3.39) *3J E JIS 63K 175(6.89) 130(5.12) 4 25(0.98) 32(1.26) 0 27(1.06) 86(3.39) *3A 1 ANSI Class 150 127(5.00) 98.6(3.88) 4 15.7(0.62) 17.5(0.69) 1.6(0.06) 27(1.06) 86(3.39) *3A 2 ANSI Class 300 155.4(6.12) 114.3(4.50) 4 22.4(0.88) 20.6(0.81) 1.6(0.06) 27(1.06) 86(3.39) *3A 4 ANSI Class 600 155.4(6.12) 114.3(4.50) 4 22.4(0.88) 28.8(1.13) 6.4(0.25) 27(1.06) 86(3.39) *3P 1 JPI Class 150 127(5.00) 98.6(3.88) 4 16(0.63) 18(0.71) 1.6(0.06) 27(1.06) 86(3.39) *3P 2 JPI Class 300 155(6.10) 114.3(4.50) 4 22(0.87) 21(0.83) 1.6(0.06) 27(1.06) 86(3.39) *3P 4 JPI Class 600 155(6.10) 114.3(4.50) 4 22(0.87) 29(1.14) 6.4(0.25) 27(1.06) 86(3.39) *3

*2: ForflangematerialcodeA(S25C),valueoffis0mm.*3: AlwaysuseincombinationwithC10FR.(ød=44mm)*4: ForsealingfacematerialcodeU(titanium),valueofTis34mm.

Page 106: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

106

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Nov. 20, 2019-00

[RingJoint(RJ),CapillaryConnectedtotheSideofDiaphragmSealUnit]Unit: mm (approx. inch)

F79E.ai

t

øgøC

T

øD

f

n-øh

ød

Capillarylength

Groove number

Processflangesize:3-inch(80mm)FlangeStandardCode

FlangeRatingCode

FlangeRating øD øCBoltholes

ød t f*1 T øg GrooveNo.No.(n) Dia.(øh)

A 2 ANSI Class 300 209.6(8.25) 168.1(6.62) 8 22.4(0.88) 90(3.54) 28.4(1.12) 1.6(0.06) 25(0.98) 147(5.79) R31A 4 ANSI Class 600 209.6(8.25) 168.1(6.62) 8 22.4(0.88) 90(3.54) 38.4(1.51) 6.4(0.25) 25(0.98) 147(5.79) R31A 5 ANSI Class 900 241.3(9.50) 190.5(7.50) 8 25.4(1.00) 90(3.54) 38.1(1.50) 0 25(0.98) 156(6.14) R31A 6 ANSI Class 1500 266.7(10.50) 203.5(8.01) 8 31.8(1.25) 90(3.54) 47.8(1.88) 0 25(0.98) 169(6.65) R35P 2 JPI Class 300 210(8.27) 168.1(6.62) 8 22(0.87) 90(3.54) 28.5(1.12) 1.6(0.06) 25(0.98) 147(5.79) R31P 4 JPI Class 600 210(8.27) 168.1(6.62) 8 22(0.87) 90(3.54) 38.4(1.51) 6.4(0.25) 25(0.98) 147(5.79) R31P 5 JPI Class 900 241(9.49) 190.5(7.50) 8 26(1.02) 90(3.54) 38.5(1.52) 0 25(0.98) 156(6.14) R31P 6 JPI Class 1500 267(10.51) 203.2(8.00) 8 32(1.26) 90(3.54) 48(1.89) 0 25(0.98) 169(6.65) R35

Processflangesize:2-inch(50mm)FlangeStandardCode

FlangeRatingCode

FlangeRating øD øCBoltholes

ød t f*1 T øg GrooveNo.No.(n) Dia.(øh)

A 2 ANSI Class 300 165.1(6.50) 127(5.00) 8 19.1(0.75) 61(2.40) 22.4(0.88) 1.6(0.06) 30(1.18) 110(4.33) R23A 4 ANSI Class 600 165.1(6.50) 127(5.00) 8 19.1(0.75) 61(2.40) 31.8(1.25) 6.4(0.25) 30(1.18) 110(4.33) R23A 5 ANSI Class 900 215.9(8.50) 165.1(6.50) 8 25.4(1.00) 61(2.40) 38.1(1.50) 0 25(0.98) 125(4.92) R24A 6 ANSI Class 1500 215.9(8.50) 165.1(6.50) 8 25.4(1.00) 61(2.40) 38.1(1.50) 0 25(0.98) 125(4.92) R24P 2 JPI Class 300 165(6.50) 127(5.00) 8 19(0.75) 61(2.40) 22.5(0.89) 1.6(0.06) 30(1.18) 110(4.33) R23P 4 JPI Class 600 165(6.50) 127(5.00) 8 19(0.75) 61(2.40) 31.9(1.26) 6.4(0.25) 30(1.18) 110(4.33) R23P 5 JPI Class 900 216(8.50) 165.1(6.50) 8 26(1.02) 61(2.40) 38.5(1.52) 0 25(0.98) 125(4.92) R24P 6 JPI Class 1500 216(8.50) 165.1(6.50) 8 26(1.02) 61(2.40) 38.5(1.52) 0 25(0.98) 125(4.92) R24

*1: ForflangematerialcodeA(S25C),valueoffis0mm.

Page 107: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

107<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Nov. 20, 2019-00

[RaisedFace(RF),CapillaryConnectedtotheBackofDiaphragmSealUnit]Unit: mm (approx. inch)

F80E.ai

*1: Indicates inside diameter of gasket contact surface.

n-øhCapillarylength

øgøCøD

f

25(0

.98)

t

ød*1

n-øh

øgøCøD

f25

(0.9

8)t

High pressure side: compensating capillary

Low pressure side: diaphragm seal capillary

With compensating capillary

P

PP

200(7.87)100(3.94)

Transmitter Connection TypeSC

Processflangesize:3-inch(80mm)FlangeStandardCode

FlangeRatingCode FlangeRating øD øC

Boltholesøg t f ødNo.(n) Dia.(øh)

J A JIS 10K 185(7.28) 150(5.91) 8 19(0.75) 130(5.12) 18(0.71) 0

90 (3.54)

J B JIS 20K 200(7.87) 160(6.30) 8 23(0.91) 130(5.12) 22(0.87) 0J C JIS 30K 210(8.27) 170(6.69) 8 23(0.91) 130(5.12) 28(1.10) 0J D JIS 40K 210(8.27) 170(6.69) 8 23(0.91) 130(5.12) 32(1.26) 0J E JIS 63K 230(9.06) 185(7.28) 8 25(0.98) 130(5.12) 40(1.57) 0A 1 ANSI Class 150 190.5(7.50) 152.4(6.00) 4 19.1(0.75) 130(5.12) 23.9(0.94) 1.6(0.06)A 2 ANSI Class 300 209.6(8.25) 168.1(6.62) 8 22.4(0.88) 130(5.12) 28.4(1.12) 1.6(0.06)A 4 ANSI Class 600 209.6(8.25) 168.1(6.62) 8 22.4(0.88) 130(5.12) 38.4(1.51) 6.4(0.25)P 1 JPI Class 150 190(7.48) 152.4(6.00) 4 19(0.75) 130(5.12) 24(0.94) 1.6(0.06)P 2 JPI Class 300 210(8.27) 168.1(6.62) 8 22(0.87) 130(5.12) 28.5(1.12) 1.6(0.06)P 4 JPI Class 600 210(8.27) 168.1(6.62) 8 22(0.87) 130(5.12) 38.4(1.51) 6.4(0.25)

Processflangesize:2-inch(50mm)FlangeStandardCode

FlangeRatingCode FlangeRating øD øC

Boltholesøg t f ødNo.(n) Dia.(øh)

J A JIS 10K 155(6.10) 120(4.72) 4 19(0.75) 100(3.94) 16(0.63) 0

61 (2.40)

J B JIS 20K 155(6.10) 120(4.72) 8 19(0.75) 100(3.94) 18(0.71) 0J C JIS 30K 165(6.50) 130(5.12) 8 19(0.75) 100(3.94) 22(0.87) 0J D JIS 40K 165(6.50) 130(5.12) 8 19(0.75) 100(3.94) 26(1.02) 0J E JIS 63K 185(7.28) 145(5.71) 8 23(0.91) 100(3.94) 34(1.34) 0A 1 ANSI Class 150 152.4(6.00) 120.7(4.75) 4 19.1(0.75) 100(3.94) 19.1(0.75) 1.6(0.06)A 2 ANSI Class 300 165.1(6.50) 127(5.00) 8 19.1(0.75) 100(3.94) 22.4(0.88) 1.6(0.06)A 4 ANSI Class 600 165.1(6.50) 127(5.00) 8 19.1(0.75) 100(3.94) 31.8(1.25) 6.4(0.25)P 1 JPI Class 150 152(5.98) 120.6(4.75) 4 19(0.75) 100(3.94) 19.5(0.77) 1.6(0.06)P 2 JPI Class 300 165(6.50) 127(5.00) 8 19(0.75) 100(3.94) 22.5(0.89) 1.6(0.06)P 4 JPI Class 600 165(6.50) 127(5.00) 8 19(0.75) 100(3.94) 31.9(1.26) 6.4(0.25)

Page 108: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

108

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Nov. 20, 2019-00

C80FERemoteMountFlangedDiaphragmSeal(ExtendedType)Unit: mm (approx. inch)

F81E.ai

High pressure side: compensating capillary

Low pressure side: diaphragm seal capillary

With compensating capillary

n-øhCapillarylength*1

f 14(0

.55)

øAøgøCøD

X2

t

120

(4.7

2)

ø30(ø1.18)

*1: The specified capillary length includes the extension length (X2) and the flange thickness (t).

øAøgøCøD

f

14(0

.55)

X2

t

n-øh

120

(4.7

2)

ø30(ø1.18)

Extendedlength(X2)Extendedlength X2

2 50±0.5(1.97±0.02)4 100±0.5(3.94±0.02)6 150±0.5(5.91±0.02)8 200±0.8(7.87±0.03)

Page 109: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

109<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Nov. 20, 2019-00

Unit: mm (approx. inch)

Processflangesize:4-inch(100mm)FlangeStandardCode

FlangeRatingCode FlangeRating øD øC

Boltholesøg øA t f*2No.(n) Dia.(øh)

J A JIS 10K 210(8.27) 175(6.89) 8 19(0.75) 155(6.10) 96±0.5(3.78±0.02) 18(0.71) 0J B JIS 20K 225(8.86) 185(7.28) 8 23(0.91) 155(6.10) 96±0.5(3.78±0.02) 24(0.94) 0J C JIS 30K 240(9.45) 195(7.68) 8 25(0.98) 155(6.10) 96±0.5(3.78±0.02) 32(1.26) 0J D JIS 40K 250(9.84) 205(8.07) 8 25(0.98) 155(6.10) 96±0.5(3.78±0.02) 36(1.42) 0A 1 ANSI Class 150 228.6(9.00) 190.5(7.50) 8 19.1(0.75) 155(6.10) 96±0.5(3.78±0.02) 23.9(0.94) 1.6(0.06)A 2 ANSI Class 300 254(10.00) 200.2(7.88) 8 22.4(0.88) 155(6.10) 96±0.5(3.78±0.02) 31.8(1.25) 1.6(0.06)A 4 ANSI Class 600 273(10.75) 215.9(8.50) 8 26(1.02) 155(6.10) 96±0.5(3.78±0.02) 44.5(1.75)*3 6.4(0.25)A 5 ANSI Class 900 292.1(11.50) 235(9.25) 8 31.8(1.25) 155(6.10) 96±0.5(3.78±0.02) 44.5(1.75) 0A 6 ANSI Class 1500 311.2(12.25) 241.3(9.50) 8 35.1(1.38) 155(6.10) 96±0.5(3.78±0.02) 53.8(2.12) 0P 1 JPI Class 150 229(9.02) 190.5(7.50) 8 19(0.75) 155(6.10) 96±0.5(3.78±0.02) 24(0.94) 1.6(0.06)P 2 JPI Class 300 254(10.00) 200.2(7.88) 8 22(0.87) 155(6.10) 96±0.5(3.78±0.02) 32(1.26) 1.6(0.06)P 4 JPI Class 600 273(10.75) 215.9(8.50) 8 26(1.02) 155(6.10) 96±0.5(3.78±0.02) 44.9(1.77) 6.4(0.25)P 5 JPI Class 900 292(11.50) 235(9.25) 8 32(1.26) 155(6.10) 96±0.5(3.78±0.02) 44.5(1.75) 0P 6 JPI Class 1500 311(12.24) 241.3(9.50) 8 35(1.38) 155(6.10) 96±0.5(3.78±0.02) 54(2.13) 0D H DINPN10/16 220(8.66) 180(7.09) 8 18(0.71) 155(6.10) 96±0.5(3.78±0.02) 20(0.79) 0D K DINPN25/40 235(9.25) 190(7.48) 8 22(0.87) 155(6.10) 96±0.5(3.78±0.02) 24(0.94) 0

Processflangesize:3-inch(80mm)FlangeStandardCode

FlangeRatingCode FlangeRating øD øC

Boltholesøg øA t fNo.(n) Dia.(øh)

J A JIS 10K 185(7.28) 150(5.91) 8 19(0.75) 130(5.12) 71±0.5(2.80±0.02) 18(0.71) 0J B JIS 20K 200(7.87) 160(6.30) 8 23(0.91) 130(5.12) 71±0.5(2.80±0.02) 22(0.87) 0J C JIS 30K 210(8.27) 170(6.69) 8 23(0.91) 130(5.12) 71±0.5(2.80±0.02) 28(1.10) 0J D JIS 40K 210(8.27) 170(6.69) 8 23(0.91) 130(5.12) 71±0.5(2.80±0.02) 32(1.26) 0A 1 ANSI Class 150 190.5(7.50) 152.4(6.00) 4 19.1(0.75) 130(5.12) 71±0.5(2.80±0.02) 23.9(0.94) 1.6(0.06)*4A 2 ANSI Class 300 209.6(8.25) 168.1(6.62) 8 22.4(0.88) 130(5.12) 71±0.5(2.80±0.02) 28.4(1.12) 1.6(0.06)*4A 4 ANSI Class 600 209.6(8.25) 168.1(6.62) 8 22.4(0.88) 130(5.12) 71±0.5(2.80±0.02) 38.4(1.51)*8 6.4(0.25)*2A 5 ANSI Class 900 241.3(9.50) 190.5(7.50) 8 25.4(1.00) 130(5.12) 71±0.5(2.80±0.02) 38.1(1.50) 0A 6 ANSI Class 1500 266.7(10.50) 203.2(8.00) 8 31.8(1.25) 130(5.12) 71±0.5(2.80±0.02) 47.8(1.88) 0P 1 JPI Class 150 190(7.48) 152.4(6.00) 4 19(0.75) 130(5.12) 71±0.5(2.80±0.02) 24(0.94) 1.6(0.06)P 2 JPI Class 300 210(8.27) 168.1(6.62) 8 22(0.87) 130(5.12) 71±0.5(2.80±0.02) 28.5(1.12) 1.6(0.06)P 4 JPI Class 600 210(8.27) 168.1(6.62) 8 22(0.87) 130(5.12) 71±0.5(2.80±0.02) 38.4(1.51)*5 6.4(0.25)*2P 5 JPI Class 900 241(9.49) 190.5(7.50) 8 26(1.02) 130(5.12) 71±0.5(2.80±0.02) 38.5(1.52)*6 0*7

P 6 JPI Class 1500 267(10.51) 203.2(8.00) 8 32(1.26) 130(5.12) 71±0.5(2.80±0.02) 48(1.89) 0D H DINPN10/16 200(7.87) 160(6.30) 8 18(0.71) 130(5.12) 71±0.5(2.80±0.02) 20(0.79) 0D K DINPN25/40 200(7.87) 160(6.30) 8 18(0.71) 130(5.12) 71±0.5(2.80±0.02) 24(0.94) 0

*2: ForflangematerialcodeA(S25C),valueoffis0mm*3: ForflangematerialcodeA(S25C),valueoftis38.5mm.*4: ForflangematerialcodeS(SUS316L),valueoffis0mm.*5: ForflangematerialcodeA(S25C),valueoftis32mm.*6: ForflangematerialcodeC(SUS316),valueoftis44.5mm.*7: ForflangematerialcodeC(SUS316),valueoftis6.4mm.*8: ForflangematerialcodeA(S25C),valueoftis31.8mm.

Page 110: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

110

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Nov. 20, 2019-00

C81FA,C82FARemoteMountInnerDiaphragmAdapterConnectionSeal[RaisedFace(RF)]

Unit: mm (approx. inch)

F82E.ai

øg

øC

øD With long vent

m+24.5(0.96)*2

n-S

L

T

f

øg

øC

øD Process

Stud bolt*1

(Nut included)

n-S

L

T

f

ø106(4.17)

High pressure side Low pressure side

A*4

Vent/Drain plugs

C82FA

Capillary length

Vent/Drain plugs

Vent/Drain plugs

Process

Stud bolt*1

(Nut included)

C81FA

*1: Stud bolts and nuts are attached for n pcs. (2×n pcs for C81FA)*2: In the case of oil-prohibited use or oil-prohibited use with dehydrating treatment, +15 mm(0.59 inch).*3: In the case of oil-prohibited use or oil-prohibited use with dehydrating treatment, +11 mm(0.43 inch).*4: In the case of C81FA, the capillaries are bundled at “A”, having 1 m(39.37 inch) left unbundled towards the remote seal part.

Capillary length

m+109.5(4.31)*3

ø106(4.17)

Without plugsm

m+24.5(0.96)*2

Page 111: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

111<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Nov. 20, 2019-00

Unit: mm (approx. inch)

[Forgeneraluse(Flangeusagecode-S,-P)]

Processflangesize:15A(1/2B)FlangeStandardCode

FlangeRatingCode FlangeRating øD øC*1 øg T*2 f m n S L

(Reference)

J A JIS 10K 95(3.74) 70(2.76) 51(2.01) 52(2.05) 1(0.04) 50(1.97) 4 M12×1.75 43(1.69)J B JIS 20K 95(3.74) 70(2.76) 51(2.01) 52(2.05) 1(0.04) 50(1.97) 4 M12×1.75 43(1.69)J C JIS 30K 115(4.53) 80(3.15) 55(2.17) 52(2.05) 1(0.04) 57.5(2.26) 4 M16×2.0 57(2.24)J D JIS 40K 115(4.53) 80(3.15) 55(2.17) 52(2.05) 1(0.04) 57.5(2.26) 4 M16×2.0 57(2.24)A 1 ANSI class 150 88.9(3.50) 60.5(2.38) 35.1(1.38) 52(2.05) 1.6(0.06) 50(1.97) 4 1/2-13UNC 44(1.73)A 2 ANSI class 300 95.3(3.75) 66.5(2.62) 35.1(1.38) 52(2.05) 1.6(0.06) 50(1.97) 4 1/2-13UNC 44(1.73)A 4 ANSI class 600 95.3(3.75) 66.5(2.62) 35.1(1.38) 62(2.44) 6.4(0.25) 53(2.09) 4 1/2-13UNC 59(2.32)P 1 JPI class 150 89(3.50) 60.5(2.38) 35.1(1.38) 52(2.05) 1.6(0.06) 50(1.97) 4 1/2-13UNC 44(1.73)P 2 JPI class 300 95(3.74) 66.5(2.62) 35.1(1.38) 52(2.05) 1.6(0.06) 50(1.97) 4 1/2-13UNC 44(1.73)P 4 JPI class 600 95(3.74) 66.5(2.62) 35.1(1.38) 62(2.44) 6.4(0.25) 53(2.09) 4 1/2-13UNC 59(2.32)

Processflangesize:20A(3/4B)FlangeStandardCode

FlangeRatingCode FlangeRating øD øC*1 øg T*2 f m n S L

(Reference)

J A JIS 10K 100(3.94) 75(2.95) 56(2.20) 52(2.05) 1(0.04) 50(1.97) 4 M12×1.75 43(1.69)J B JIS 20K 100(3.94) 75(2.95) 56(2.20) 52(2.05) 1(0.04) 50(1.97) 4 M12×1.75 43(1.69)J C JIS 30K 120(4.72) 85(3.35) 60(2.36) 52(2.05) 1(0.04) 60(2.36) 4 M16×2.0 57(2.24)J D JIS 40K 120(4.72) 85(3.35) 60(2.36) 52(2.05) 1(0.04) 60(2.36) 4 M16×2.0 57(2.24)A 1 ANSI class 150 98.6(3.75) 69.9(2.75) 42.9(1.69) 52(2.05) 1.6(0.06) 50(1.97) 4 1/2-13UNC 44(1.73)A 2 ANSI class 300 117.3(4.62) 82.6(3.25) 42.9(1.69) 52(2.05) 1.6(0.06) 58.7(2.31) 4 5/8-11UNC 51(2.01)A 4 ANSI class 600 117.3(4.62) 82.6(3.25) 42.9(1.69) 62(2.44) 6.4(0.25) 58.7(2.31) 4 5/8-11UNC 67(2.64)P 1 JPI class 150 99(3.90) 69.8(2.75) 42.9(1.69) 52(2.05) 1.6(0.06) 50(1.97) 4 1/2-13UNC 44(1.73)P 2 JPI class 300 117(4.61) 82.6(3.25) 42.9(1.69) 52(2.05) 1.6(0.06) 58.7(2.31) 4 5/8-11UNC 51(2.01)P 4 JPI class 600 117(4.61) 82.6(3.25) 42.9(1.69) 62(2.44) 6.4(0.25) 58.7(2.31) 4 5/8-11UNC 67(2.64)

Processflangesize:25A(1B)FlangeStandardCode

FlangeRatingCode FlangeRating øD øC*1 øg T*2 f m n S L

(Reference)

J A JIS 10K 125(4.92) 90(3.54) 67(2.64) 52(2.05) 1(0.04) 62.5(2.46) 4 M16×2.0 57(2.24)J B JIS 20K 125(4.92) 90(3.54) 67(2.64) 52(2.05) 1(0.04) 62.5(2.46) 4 M16×2.0 57(2.24)J C JIS 30K 130(5.12) 95(3.74) 70(2.76) 52(2.05) 1(0.04) 65(2.56) 4 M16×2.0 57(2.24)J D JIS 40K 130(5.12) 95(3.74) 70(2.76) 52(2.05) 1(0.04) 65(2.56) 4 M16×2.0 57(2.24)A 1 ANSI class 150 108(4.25) 79.2(3.12) 50.8(2.00) 52(2.05) 1.6(0.06) 54(2.13) 4 1/2-13UNC 44(1.73)A 2 ANSI class 300 124(4.88) 88.9(3.50) 50.8(2.00) 52(2.05) 1.6(0.06) 62(2.44) 4 5/8-11UNC 51(2.01)A 4 ANSI class 600 124(4.88) 88.9(3.50) 50.8(2.00) 62(2.44) 6.4(0.25) 62(2.44) 4 5/8-11UNC 67(2.64)P 1 JPI class 150 108(4.25) 79.2(3.12) 50.8(2.00) 52(2.05) 1.6(0.06) 54(2.13) 4 1/2-13UNC 44(1.73)P 2 JPI class 300 124(4.88) 88.9(3.50) 50.8(2.00) 52(2.05) 1.6(0.06) 62(2.44) 4 5/8-11UNC 51(2.01)P 4 JPI class 600 124(4.88) 88.9(3.50) 50.8(2.00) 62(2.44) 6.4(0.25) 62(2.44) 4 5/8-11UNC 67(2.64)

*1: Thisvalueisthesameasflangestandards.Actualvaluemightbeadded1mm(0.04inch)becausethecommercialgasketscanbeused.

*2: UsethefollowingvalueforsizeTwhentantalum(code:T)isspecifiedfordiaphragmmaterial; 58mm(2.28inch)forJISflange 59mm(2.32inch)forANSIandJPIflange.

Page 112: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

112

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Nov. 20, 2019-00

Unit: mm (approx. inch)

[Forhightemperatureuse(Flangeusagecode-H)]

Processflangesize:15A(1/2B)FlangeStandardCode

FlangeRatingCode FlangeRating øD øC*1 øg T f m n S L

(Reference)

J A JIS 10K 120(4.72) 70(2.76) 51(2.01) 54.5(2.15) 1(0.04) 60(2.36) 4 M12×1.75 43(1.69)J B JIS 20K 120(4.72) 70(2.76) 51(2.01) 54.5(2.15) 1(0.04) 60(2.36) 4 M12×1.75 43(1.69)J C JIS 30K 120(4.72) 80(3.15) 55(2.17) 54.5(2.15) 1(0.04) 60(2.36) 4 M16×2.0 57(2.24)J D JIS 40K 120(4.72) 80(3.15) 55(2.17) 54.5(2.15) 1(0.04) 60(2.36) 4 M16×2.0 57(2.24)A 1 ANSI class 150 120(4.72) 60.5(2.38) 35.1(1.38) 54.5(2.15) 1.6(0.06) 60(2.36) 4 1/2-13UNC 44(1.73)A 2 ANSI class 300 120(4.72) 66.5(2.62) 35.1(1.38) 54.5(2.15) 1.6(0.06) 60(2.36) 4 1/2-13UNC 44(1.73)A 4 ANSI class 600 120(4.72) 66.5(2.62) 35.1(1.38) 65.1(2.56) 6.4(0.25) 60(2.36) 4 1/2-13UNC 59(2.32)P 1 JPI class 150 120(4.72) 60.5(2.38) 35.1(1.38) 54.5(2.15) 1.6(0.06) 60(2.36) 4 1/2-13UNC 44(1.73)P 2 JPI class 300 120(4.72) 66.5(2.62) 35.1(1.38) 54.5(2.15) 1.6(0.06) 60(2.36) 4 1/2-13UNC 44(1.73)P 4 JPI class 600 120(4.72) 66.5(2.62) 35.1(1.38) 65.1(2.56) 6.4(0.25) 60(2.36) 4 1/2-13UNC 59(2.32)

Processflangesize:20A(3/4B)FlangeStandardCode

FlangeRatingCode FlangeRating øD øC*1 øg T f m n S L

(Reference)

J A JIS 10K 120(4.72) 75(2.95) 56(2.20) 54.5(2.15) 1(0.04) 60(2.36) 4 M12×1.75 43(1.69)J B JIS 20K 120(4.72) 75(2.95) 56(2.20) 54.5(2.15) 1(0.04) 60(2.36) 4 M12×1.75 43(1.69)J C JIS 30K 120(4.72) 85(3.35) 60(2.36) 54.5(2.15) 1(0.04) 60(2.36) 4 M16×2.0 57(2.24)J D JIS 40K 120(4.72) 85(3.35) 60(2.36) 54.5(2.15) 1(0.04) 60(2.36) 4 M16×2.0 57(2.24)A 1 ANSI class 150 120(4.72) 69.9(2.75) 42.9(1.69) 54.5(2.15) 1.6(0.06) 60(2.36) 4 1/2-13UNC 44(1.73)A 2 ANSI class 300 120(4.72) 82.6(3.25) 42.9(1.69) 54.5(2.15) 1.6(0.06) 60(2.36) 4 5/8-11UNC 51(2.01)A 4 ANSI class 600 120(4.72) 82.6(3.25) 42.9(1.69) 65.1(2.56) 6.4(0.25) 60(2.36) 4 5/8-11UNC 67(2.64)P 1 JPI class 150 120(4.72) 69.8(2.75) 42.9(1.69) 54.5(2.15) 1.6(0.06) 60(2.36) 4 1/2-13UNC 44(1.73)P 2 JPI class 300 120(4.72) 82.6(3.25) 42.9(1.69) 54.5(2.15) 1.6(0.06) 60(2.36) 4 5/8-11UNC 51(2.01)P 4 JPI class 600 120(4.72) 82.6(3.25) 42.9(1.69) 65.1(2.56) 6.4(0.25) 60(2.36) 4 5/8-11UNC 67(2.64)

Processflangesize:25A(1B)FlangeStandardCode

FlangeRatingCode FlangeRating øD øC*1 øg T f m n S L

(Reference)

J A JIS 10K 125(4.92) 90(3.54) 67(2.64) 54.5(2.15) 1(0.04) 62.5(2.46) 4 M16×2.0 57(2.24)J B JIS 20K 125(4.92) 90(3.54) 67(2.64) 54.5(2.15) 1(0.04) 62.5(2.46) 4 M16×2.0 57(2.24)J C JIS 30K 130(5.12) 95(3.74) 70(2.76) 54.5(2.15) 1(0.04) 65(2.56) 4 M16×2.0 57(2.24)J D JIS 40K 130(5.12) 95(3.74) 70(2.76) 54.5(2.15) 1(0.04) 65(2.56) 4 M16×2.0 57(2.24)A 1 ANSI class 150 120(4.72) 79.2(3.12) 50.8(2.00) 54.5(2.15) 1.6(0.06) 60(2.36) 4 1/2-13UNC 44(1.73)A 2 ANSI class 300 124(4.88) 88.9(3.50) 50.8(2.00) 54.5(2.15) 1.6(0.06) 62(2.44) 4 5/8-11UNC 51(2.01)A 4 ANSI class 600 124(4.88) 88.9(3.50) 50.8(2.00) 65.1(2.56) 6.4(0.25) 62(2.44) 4 5/8-11UNC 67(2.64)P 1 JPI class 150 120(4.72) 79.2(3.12) 50.8(2.00) 54.5(2.15) 1.6(0.06) 60(2.36) 4 1/2-13UNC 44(1.73)P 2 JPI class 300 124(4.88) 88.9(3.50) 50.8(2.00) 54.5(2.15) 1.6(0.06) 62(2.44) 4 5/8-11UNC 51(2.01)P 4 JPI class 600 124(4.88) 88.9(3.50) 50.8(2.00) 65.1(2.56) 6.4(0.25) 62(2.44) 4 5/8-11UNC 67(2.64)

*1: Thisvalueisthesameasflangestandards.Actualvaluemightbeadded1mm(0.04inch)becausethecommercialgasketscanbeused.

Page 113: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

113<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Nov. 20, 2019-00

[RingJoint(RJ)]Unit: mm (approx. inch)

F83E.ai

m

øg

øC

øD

m+2.45(0.96)*2

n-S

L f

øg

øC

øD

n-S

L

Tf

A*4

m+109.5(4.31)*3

Process

Stud bolt*1

(Nut included)

High pressure side Low pressure side

Vent/Drain plugs

C82FA

Capillary length

Groove Number

Vent/Drain plugs

ProcessStud bolt*1

(Nut included)

C81FA

Capillary length

With long vent

Vent/Drain plugs

Groove Number

*1: Stud bolts and nuts are attached for n pcs. (2×n pcs for C81FA)*2: In the case of oil-prohibited use or oil-prohibited use with dehydrating treatment, +15 mm(0.59 inch).*3: In the case of oil-prohibited use or oil-prohibited use with dehydrating treatment, +11 mm(0.43 inch).*4: In the case of C81FA, the capillaries are bundled at “A”, having 1 m(39.37 inch) left unbundled towards the remote seal part.

ø106(4.17)

ø106(4.17)

m+2.45(0.96)*2

TWithout plugs

Page 114: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

114

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Nov. 20, 2019-00

Unit: mm (approx. inch)

[Forgeneraluse(Flangeusagecode-S,-P)]

Processflangesize:15A(1/2B)FlangeStandardCode

FlangeRatingCode

FlangeRating øD øC øg T*1 f m n S L(Reference)

Groovenumber

A 2 ANSI class 300 95.3(3.75) 66.5(2.62) 50.8(2.00) 56.4(2.22) 5.56(0.22) 50(1.97) 4 1/2-13UNC 44(1.73) R11A 4 ANSI class 600 95.3(3.75) 66.5(2.62) 50.8(2.00) 61.5(2.42) 5.56(0.22) 53(2.09) 4 1/2-13UNC 59(2.32) R11P 2 JPI class 300 95(3.74) 66.5(2.62) 51(2.01) 56.4(2.22) 5.56(0.22) 50(1.97) 4 1/2-13UNC 44(1.73) R11P 4 JPI class 600 95(3.74) 66.5(2.62) 51(2.01) 61.5(2.42) 5.56(0.22) 53(2.09) 4 1/2-13UNC 59(2.32) R11

Processflangesize:20A(3/4B)FlangeStandardCode

FlangeRatingCode

FlangeRating øD øC øg T*2 f m n S L(Reference)

Groovenumber

A 2 ANSI class 300 117.3(4.62) 82.6(3.25) 63.5(2.50) 56.9(2.24) 6.35(0.25) 58.7(2.31) 4 5/8-11UNC 51(2.01) R13A 4 ANSI class 600 117.3(4.62) 82.6(3.25) 63.5(2.50) 62(2.44) 6.35(0.25) 58.7(2.31) 4 5/8-11UNC 67(2.64) R13P 2 JPI class 300 117(4.61) 82.6(3.25) 63.5(2.50) 56.9(2.24) 6.35(0.25) 58.5(2.30) 4 5/8-11UNC 51(2.01) R13P 4 JPI class 600 117(4.61) 82.6(3.25) 63.5(2.50) 62(2.44) 6.35(0.25) 58.5(2.30) 4 5/8-11UNC 67(2.64) R13

Processflangesize:25A(1B)FlangeStandardCode

FlangeRatingCode

FlangeRating øD øC øg T*2 f m n S L(Reference)

Groovenumber

A 2 ANSI class 300 124(4.88) 88.9(3.50) 69.9(2.75) 56.9(2.24) 6.35(0.25) 62(2.44) 4 5/8-11UNC 51(2.01) R16A 4 ANSI class 600 124(4.88) 88.9(3.50) 69.9(2.75) 62(2.44) 6.35(0.25) 62(2.44) 4 5/8-11UNC 67(2.64) R16P 2 JPI class 300 124(4.88) 88.9(3.50) 70(2.76) 56.9(2.24) 6.35(0.25) 62(2.44) 4 5/8-11UNC 51(2.01) R16P 4 JPI class 600 124(4.88) 88.9(3.50) 70(2.76) 62(2.44) 6.35(0.25) 62(2.44) 4 5/8-11UNC 67(2.64) R16

*1: SizeTis63mm(2.48inch)whentantalum(code:T)isspecifiedfordiaphragmmaterial.*2: SizeTis64mm(2.52inch)whentantalum(code:T)isspecifiedfordiaphragmmaterial.

[Forhightemperatureuse(Flangeusagecode-H)]

Processflangesize:15A(1/2B)FlangeStandardCode

FlangeRatingCode

FlangeRating øD øC øg T f m n S L(Reference)

Groovenumber

A 2 ANSI class 300 120(4.72) 66.5(2.62) 50.8(2.00) 60(2.36) 5.56(0.22) 60(2.36) 4 1/2-13UNC 44(1.73) R11A 4 ANSI class 600 120(4.72) 66.5(2.62) 50.8(2.00) 65.1(2.56) 5.56(0.22) 60(2.36) 4 1/2-13UNC 59(2.32) R11P 2 JPI class 300 120(4.72) 66.5(2.62) 51(2.01) 60(2.36) 5.56(0.22) 60(2.36) 4 1/2-13UNC 44(1.73) R11P 4 JPI class 600 120(4.72) 66.5(2.62) 51(2.01) 65.1(2.56) 5.56(0.22) 60(2.36) 4 1/2-13UNC 59(2.32) R11

Processflangesize:20A(3/4B)FlangeStandardCode

FlangeRatingCode

FlangeRating øD øC øg T f m n S L(Reference)

Groovenumber

A 2 ANSI class 300 120(4.72) 82.6(3.25) 63.5(2.50) 60(2.36) 6.35(0.25) 60(2.36) 4 5/8-11UNC 51(2.01) R13A 4 ANSI class 600 120(4.72) 82.6(3.25) 63.5(2.50) 65.1(2.56) 6.35(0.25) 60(2.36) 4 5/8-11UNC 67(2.64) R13P 2 JPI class 300 120(4.72) 82.6(3.25) 63.5(2.50) 60(2.36) 6.35(0.25) 60(2.36) 4 5/8-11UNC 51(2.01) R13P 4 JPI class 600 120(4.72) 82.6(3.25) 63.5(2.50) 65.1(2.56) 6.35(0.25) 60(2.36) 4 5/8-11UNC 67(2.64) R13

Processflangesize:25A(1B)FlangeStandardCode

FlangeRatingCode

FlangeRating øD øC øg T f m n S L(Reference)

Groovenumber

A 2 ANSI class 300 124(4.88) 88.9(3.50) 69.9(2.75) 60(2.36) 6.35(0.25) 62(2.44) 4 5/8-11UNC 51(2.01) R16A 4 ANSI class 600 124(4.88) 88.9(3.50) 69.9(2.75) 65.1(2.56) 6.35(0.25) 62(2.44) 4 5/8-11UNC 67(2.64) R16P 2 JPI class 300 124(4.88) 88.9(3.50) 70(2.76) 60(2.36) 6.35(0.25) 62(2.44) 4 5/8-11UNC 51(2.01) R16P 4 JPI class 600 124(4.88) 88.9(3.50) 70(2.76) 65.1(2.56) 6.35(0.25) 62(2.44) 4 5/8-11UNC 67(2.64) R16

Page 115: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

115<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Nov. 20, 2019-00

C81FD,C82FDRemoteMountInnerDiaphragmFlangedSeal[RaisedFace(RF)]

Unit: mm (approx. inch)

F84E.ai

m

m+24.5(0.96)*1

øgøD

With long vent

øg

øDProcess

T

ø106(4.17)

High pressure side Low pressure side

Vent/Drain plugs

C82FD

Capillary length

Vent/Drain plugs

Vent/Drain plugs

Process

C81FD

*1: In the case of oil-prohibited use or oil-prohibited use with dehydrating treatment, +15 mm(0.59 inch).*2: In the case of oil-prohibited use or oil-prohibited use with dehydrating treatment, +11 mm(0.43 inch).*3: In the case of C81FD, the capillaries are bundled at “A”, having 1 m(39.37 inch) left unbundled towards the remote seal part.

Capillary length

m+109.5(4.31)*2T

ø106(4.17)

øC

n-øh

Ltf

øC

n-øh

Ltf

A*3

Without plugs

m+24.5(0.96)*1

Page 116: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

116

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Nov. 20, 2019-00

Unit: mm (approx. inch)

[Forgeneraluse(Flangeusagecode-S,-P)]

Processflangesize:15A(1/2B)FlangeStandardCode

FlangeRatingCode

FlangeRating øD øC øg L T*1 t f m n øh

J A JIS 10K 95(3.74) 70(2.76) 51(2.01) 108(4.25) 42(1.65) 12(0.47) 1(0.04) 53(2.09) 4 15(0.59)J B JIS 20K 95(3.74) 70(2.76) 51(2.01) 108(4.25) 42(1.65) 14(0.55) 1(0.04) 53(2.09) 4 15(0.59)J C JIS 30K 115(4.53) 80(3.15) 55(2.17) 108(4.25) 42(1.65) 18(0.71) 1(0.04) 53(2.09) 4 19(0.75)J D JIS 40K 115(4.53) 80(3.15) 55(2.17) 108(4.25) 42(1.65) 20(0.79) 1(0.04) 53(2.09) 4 19(0.75)A 1 ANSI class 150 88.9(3.50) 60.5(2.38) 35.1(1.38) 108(4.25) 42(1.65) 11.2(0.44) 1.6(0.06) 53(2.09) 4 15.7(0.62)A 2 ANSI class 300 95.3(3.75) 66.5(2.62) 35.1(1.38) 108(4.25) 42(1.65) 14.3(0.56) 1.6(0.06) 53(2.09) 4 15.7(0.62)A 4 ANSI class 600 95.3(3.75) 66.5(2.62) 35.1(1.38) 108(4.25) 57(2.24) 20.7(0.81) 6.4(0.25) 53(2.09) 4 15.7(0.62)P 1 JPI class 150 89(3.50) 60.5(2.38) 35.1(1.38) 108(4.25) 42(1.65) 11.2(0.44) 1.6(0.06) 53(2.09) 4 16(0.63)P 2 JPI class 300 95(3.74) 66.5(2.62) 35.1(1.38) 108(4.25) 42(1.65) 14.3(0.56) 1.6(0.06) 53(2.09) 4 16(0.63)P 4 JPI class 600 95(3.74) 66.5(2.62) 35.1(1.38) 108(4.25) 57(2.24) 20.7(0.81) 6.4(0.25) 53(2.09) 4 16(0.63)

Processflangesize:20A(3/4B)FlangeStandardCode

FlangeRatingCode

FlangeRating øD øC øg L T*1 t f m n øh

J A JIS 10K 100(3.94) 75(2.95) 56(2.20) 108(4.25) 42(1.65) 14(0.55) 1(0.04) 53(2.09) 4 15(0.59)J B JIS 20K 100(3.94) 75(2.95) 56(2.20) 108(4.25) 42(1.65) 16(0.63) 1(0.04) 53(2.09) 4 15(0.59)J C JIS 30K 120(4.53) 85(3.35) 60(2.36) 108(4.25) 42(1.65) 18(0.71) 1(0.04) 53(2.09) 4 19(0.75)J D JIS 40K 120(4.53) 85(3.35) 60(2.36) 108(4.25) 42(1.65) 20(0.79) 1(0.04) 53(2.09) 4 19(0.75)A 1 ANSI class 150 98.6(3.88) 69.9(2.75) 42.9(1.69) 108(4.25) 42(1.65) 12.7(0.50) 1.6(0.06) 53(2.09) 4 15.7(0.62)A 2 ANSI class 300 117.3(4.62) 82.6(3.25) 42.9(1.69) 108(4.25) 42(1.65) 15.8(0.62) 1.6(0.06) 53(2.09) 4 19.1(0.75)A 4 ANSI class 600 117.3(4.62) 82.6(3.25) 42.9(1.69) 108(4.25) 57(2.24) 22.2(0.87) 6.4(0.25) 53(2.09) 4 19.1(0.75)P 1 JPI class 150 99(3.90) 69.8(2.75) 42.9(1.69) 108(4.25) 42(1.65) 12.7(0.50) 1.6(0.06) 53(2.09) 4 16(0.63)P 2 JPI class 300 117(4.61) 82.6(3.25) 42.9(1.69) 108(4.25) 42(1.65) 15.8(0.62) 1.6(0.06) 53(2.09) 4 19(0.75)P 4 JPI class 600 117(4.61) 82.6(3.25) 42.9(1.69) 108(4.25) 57(2.24) 22.2(0.87) 6.4(0.25) 53(2.09) 4 19(0.75)

Processflangesize:25A(1B)FlangeStandardCode

FlangeRatingCode

FlangeRating øD øC øg L T*1 t f m n øh

J A JIS 10K 125(4.92) 90(3.54) 67(2.64) 108(4.25) 42(1.65) 14(0.55) 1(0.04) 53(2.09) 4 19(0.75)J B JIS 20K 125(4.92) 90(3.54) 67(2.64) 108(4.25) 42(1.65) 16(0.63) 1(0.04) 53(2.09) 4 19(0.75)J C JIS 30K 130(5.12) 95(3.74) 70(2.76) 108(4.25) 42(1.65) 20(0.79) 1(0.04) 53(2.09) 4 19(0.75)J D JIS 40K 130(5.12) 95(3.74) 70(2.76) 108(4.25) 42(1.65) 22(0.87) 1(0.04) 53(2.09) 4 19(0.75)A 1 ANSI class 150 108(4.25) 79.2(3.12) 50.8(2.00) 108(4.25) 42(1.65) 14.3(0.56) 1.6(0.06) 53(2.09) 4 15.7(0.62)A 2 ANSI class 300 124(4.88) 88.9(3.50) 50.8(2.00) 108(4.25) 42(1.65) 17.6(0.69) 1.6(0.06) 53(2.09) 4 19.1(0.75)A 4 ANSI class 600 124(4.88) 88.9(3.50) 50.8(2.00) 108(4.25) 57(2.24) 24(0.95) 6.4(0.25) 53(2.09) 4 19.1(0.75)P 1 JPI class 150 108(4.25) 79.2(3.12) 50.8(2.00) 108(4.25) 42(1.65) 14.3(0.56) 1.6(0.06) 53(2.09) 4 16(0.63)P 2 JPI class 300 124(4.88) 88.9(3.50) 50.8(2.00) 108(4.25) 42(1.65) 17.6(0.69) 1.6(0.06) 53(2.09) 4 19(0.75)P 4 JPI class 600 124(4.88) 88.9(3.50) 50.8(2.00) 108(4.25) 57(2.24) 24(0.95) 6.4(0.25) 53(2.09) 4 19(0.75)

*1: SizeTis47mm(1.85inch)whentantalum(code:T)isspecifiedfordiaphragmmaterial.

Page 117: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

117<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Nov. 20, 2019-00

Unit: mm (approx. inch)

[Forhightemperatureuse(Flangeusagecode-H)]

Processflangesize:15A(1/2B)FlangeStandardCode

FlangeRatingCode

FlangeRating øD øC øg L T t f m n øh

J A JIS 10K 95(3.74) 70(2.76) 51(2.01) 108(4.25) 51(2.01) 12(0.47) 1(0.04) 60(2.36) 4 15(0.59)J B JIS 20K 95(3.74) 70(2.76) 51(2.01) 108(4.25) 51(2.01) 14(0.55) 1(0.04) 60(2.36) 4 15(0.59)J C JIS 30K 115(4.53) 80(3.15) 55(2.17) 108(4.25) 51(2.01) 18(0.71) 1(0.04) 60(2.36) 4 19(0.75)J D JIS 40K 115(4.53) 80(3.15) 55(2.17) 108(4.25) 51(2.01) 20(0.79) 1(0.04) 60(2.36) 4 19(0.75)A 1 ANSI class 150 88.9(3.50) 60.5(2.38) 35.1(1.38) 108(4.25) 51(2.01) 11.2(0.44) 1.6(0.06) 60(2.36) 4 15.7(0.62)A 2 ANSI class 300 95.3(3.75) 66.5(2.62) 35.1(1.38) 108(4.25) 51(2.01) 14.3(0.56) 1.6(0.06) 60(2.36) 4 15.7(0.62)A 4 ANSI class 600 95.3(3.75) 66.5(2.62) 35.1(1.38) 108(4.25) 57(2.24) 20.7(0.81) 6.4(0.25) 60(2.36) 4 15.7(0.62)P 1 JPI class 150 89(3.50) 60.5(2.38) 35.1(1.38) 108(4.25) 51(2.01) 11.2(0.44) 1.6(0.06) 60(2.36) 4 16(0.63)P 2 JPI class 300 95(3.74) 66.5(2.62) 35.1(1.38) 108(4.25) 51(2.01) 14.3(0.56) 1.6(0.06) 60(2.36) 4 16(0.63)P 4 JPI class 600 95(3.74) 66.5(2.62) 35.1(1.38) 108(4.25) 57(2.24) 20.7(0.81) 6.4(0.25) 60(2.36) 4 16(0.63)

Processflangesize:20A(3/4B)FlangeStandardCode

FlangeRatingCode

FlangeRating øD øC øg L T t f m n øh

J A JIS 10K 100(3.94) 75(2.95) 56(2.20) 108(4.25) 51(2.01) 14(0.55) 1(0.04) 60(2.36) 4 15(0.59)J B JIS 20K 100(3.94) 75(2.95) 56(2.20) 108(4.25) 51(2.01) 16(0.63) 1(0.04) 60(2.36) 4 15(0.59)J C JIS 30K 120(4.53) 85(3.35) 60(2.36) 108(4.25) 51(2.01) 18(0.71) 1(0.04) 60(2.36) 4 19(0.75)J D JIS 40K 120(4.53) 85(3.35) 60(2.36) 108(4.25) 51(2.01) 20(0.79) 1(0.04) 60(2.36) 4 19(0.75)A 1 ANSI class 150 98.6(3.88) 69.9(2.75) 42.9(1.69) 108(4.25) 51(2.01) 12.7(0.50) 1.6(0.06) 60(2.36) 4 15.7(0.62)A 2 ANSI class 300 117.3(4.62) 82.6(3.25) 42.9(1.69) 108(4.25) 51(2.01) 15.8(0.62) 1.6(0.06) 60(2.36) 4 19.1(0.75)A 4 ANSI class 600 117.3(4.62) 82.6(3.25) 42.9(1.69) 108(4.25) 57(2.24) 22.2(0.87) 6.4(0.25) 60(2.36) 4 19.1(0.75)P 1 JPI class 150 99(3.90) 69.8(2.75) 42.9(1.69) 108(4.25) 51(2.01) 12.7(0.50) 1.6(0.06) 60(2.36) 4 16(0.63)P 2 JPI class 300 117(4.61) 82.6(3.25) 42.9(1.69) 108(4.25) 51(2.01) 15.8(0.62) 1.6(0.06) 60(2.36) 4 19(0.75)P 4 JPI class 600 117(4.61) 82.6(3.25) 42.9(1.69) 108(4.25) 57(2.24) 22.2(0.87) 6.4(0.25) 60(2.36) 4 19(0.75)

Processflangesize:25A(1B)FlangeStandardCode

FlangeRatingCode

FlangeRating øD øC øg L T t f m n øh

J A JIS 10K 125(4.92) 90(3.54) 67(2.64) 108(4.25) 51(2.01) 14(0.55) 1(0.04) 60(2.36) 4 19(0.75)J B JIS 20K 125(4.92) 90(3.54) 67(2.64) 108(4.25) 51(2.01) 16(0.63) 1(0.04) 60(2.36) 4 19(0.75)J C JIS 30K 130(5.12) 95(3.74) 70(2.76) 108(4.25) 51(2.01) 20(0.79) 1(0.04) 60(2.36) 4 19(0.75)J D JIS 40K 130(5.12) 95(3.74) 70(2.76) 108(4.25) 51(2.01) 22(0.87) 1(0.04) 60(2.36) 4 19(0.75)A 1 ANSI class 150 108(4.25) 79.2(3.12) 50.8(2.00) 108(4.25) 51(2.01) 14.3(0.56) 1.6(0.06) 60(2.36) 4 15.7(0.62)A 2 ANSI class 300 124(4.88) 88.9(3.50) 50.8(2.00) 108(4.25) 51(2.01) 17.6(0.69) 1.6(0.06) 60(2.36) 4 19.1(0.75)A 4 ANSI class 600 124(4.88) 88.9(3.50) 50.8(2.00) 108(4.25) 57(2.24) 24(0.95) 6.4(0.25) 60(2.36) 4 19.1(0.75)P 1 JPI class 150 108(4.25) 79.2(3.12) 50.8(2.00) 108(4.25) 51(2.01) 14.3(0.56) 1.6(0.06) 60(2.36) 4 16(0.63)P 2 JPI class 300 124(4.88) 88.9(3.50) 50.8(2.00) 108(4.25) 51(2.01) 17.6(0.69) 1.6(0.06) 60(2.36) 4 19(0.75)P 4 JPI class 600 124(4.88) 88.9(3.50) 50.8(2.00) 108(4.25) 57(2.24) 24(0.95) 6.4(0.25) 60(2.36) 4 19(0.75)

Page 118: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

118

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Nov. 20, 2019-00

[RingJoint(RJ)]Unit: mm (approx. inch)

F85E.ai

m

øg

øC

øD

n-øh

L

tf

øg

øC

øDn-øh

Ltf

A*3

Groove Number

Groove Number

With long vent

Process

T

High pressure side Low pressure side

Vent/Drain plugs

C82FD

Capillary length

Vent/Drain plugs

Vent/Drain plugs

Process

C81FD

*1: In the case of oil-prohibited use or oil-prohibited use with dehydrating treatment, +15 mm(0.59 inch).*2: In the case of oil-prohibited use or oil-prohibited use with dehydrating treatment, +11 mm(0.43 inch).*3: In the case of C81FD, the capillaries are bundled at “A”, having 1 m(39.37 inch) left unbundled towards the remote seal part.

Capillary length

Tø106(4.17)

ø106(4.17)

m+109.5(4.31)*2

Without plugs

m+24.5(0.96)*1

m+24.5(0.96)*1

Page 119: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

119<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Nov. 20, 2019-00

Unit: mm (approx. inch)

[Forgeneraluse(Flangeusagecode-S,-P)]

Processflangesize:15A(1/2B)FlangeStandardCode

FlangeRatingCode

FlangeRating øD øC øg L T*1 t f m n øh Groovenumber

A 2 ANSI class 300 95.3(3.75) 66.5(2.62) 50.8(2.00) 124(4.88) 42(1.65) 14.3(0.56) 5.56(0.22) 53(2.09) 4 16(0.63) R11A 4 ANSI class 600 95.3(3.75) 66.5(2.62) 50.8(2.00) 124(4.88) 57(2.24) 14.3(0.56) 5.56(0.22) 53(2.09) 4 16(0.63) R11P 2 JPI class 300 95(3.74) 66.5(2.62) 51(2.01) 124(4.88) 42(1.65) 14.3(0.56) 5.56(0.22) 53(2.09) 4 16(0.63) R11P 4 JPI class 600 95(3.74) 66.5(2.62) 51(2.01) 124(4.88) 57(2.24) 14.3(0.56) 5.56(0.22) 53(2.09) 4 16(0.63) R11

Processflangesize:20A(3/4B)FlangeStandardCode

FlangeRatingCode

FlangeRating øD øC øg L T*1 t f m n øh Groovenumber

A 2 ANSI class 300 117.3(4.62) 82.6(3.25) 63.5(2.50) 128(5.04) 42(1.65) 15.8(0.62) 6.35(0.25) 53(2.09) 4 19(0.75) R13A 4 ANSI class 600 117.3(4.62) 82.6(3.25) 63.5(2.50) 128(5.04) 57(2.24) 15.8(0.62) 6.35(0.25) 53(2.09) 4 19(0.75) R13P 2 JPI class 300 117(4.61) 82.6(3.25) 63.5(2.50) 127(5.00) 42(1.65) 15.8(0.62) 6.35(0.25) 53(2.09) 4 19(0.75) R13P 4 JPI class 600 117(4.61) 82.6(3.25) 63.5(2.50) 127(5.00) 57(2.24) 15.8(0.62) 6.35(0.25) 53(2.09) 4 19(0.75) R13

Processflangesize:25A(1B)FlangeStandardCode

FlangeRatingCode

FlangeRating øD øC øg L T*1 t f m n øh Groovenumber

A 2 ANSI class 300 124(4.88) 88.9(3.50) 69.9(2.75) 129(5.08) 42(1.65) 17.6(0.69) 6.35(0.25) 53(2.09) 4 19(0.75) R16A 4 ANSI class 600 124(4.88) 88.9(3.50) 69.9(2.75) 129(5.08) 57(2.24) 17.6(0.69) 6.35(0.25) 53(2.09) 4 19(0.75) R16P 2 JPI class 300 124(4.88) 88.9(3.50) 70(2.76) 129(5.08) 42(1.65) 17.6(0.69) 6.35(0.25) 53(2.09) 4 19(0.75) R16P 4 JPI class 600 124(4.88) 88.9(3.50) 70(2.76) 129(5.08) 57(2.24) 17.6(0.69) 6.35(0.25) 53(2.09) 4 19(0.75) R16

*1: SizeTis47mm(1.85inch)whentantalum(code:T)isspecifiedfordiaphragmmaterial.

[Forhightemperatureuse(Flangeusagecode-H)]

Processflangesize:15A(1/2B)FlangeStandardCode

FlangeRatingCode

FlangeRating øD øC øg L T t f m n øh Groovenumber

A 2 ANSI class 300 95.3(3.75) 66.5(2.62) 50.8(2.00) 124(4.88) 51(2.01) 14.3(0.56) 5.56(0.22) 60(2.36) 4 16(0.63) R11A 4 ANSI class 600 95.3(3.75) 66.5(2.62) 50.8(2.00) 124(4.88) 57(2.24) 14.3(0.56) 5.56(0.22) 60(2.36) 4 16(0.63) R11P 2 JPI class 300 95(3.74) 66.5(2.62) 51(2.01) 124(4.88) 51(2.01) 14.3(0.56) 5.56(0.22) 60(2.36) 4 16(0.63) R11P 4 JPI class 600 95(3.74) 66.5(2.62) 51(2.01) 124(4.88) 57(2.24) 14.3(0.56) 5.56(0.22) 60(2.36) 4 16(0.63) R11

Processflangesize:20A(3/4B)FlangeStandardCode

FlangeRatingCode

FlangeRating øD øC øg L T t f m n øh Groovenumber

A 2 ANSI class 300 117.3(4.62) 82.6(3.25) 63.5(2.50) 128(5.04) 51(2.01) 15.8(0.62) 6.35(0.25) 60(2.36) 4 19(0.75) R13A 4 ANSI class 600 117.3(4.62) 82.6(3.25) 63.5(2.50) 128(5.04) 57(2.24) 15.8(0.62) 6.35(0.25) 60(2.36) 4 19(0.75) R13P 2 JPI class 300 117(4.61) 82.6(3.25) 63.5(2.50) 127(5.00) 51(2.01) 15.8(0.62) 6.35(0.25) 60(2.36) 4 19(0.75) R13P 4 JPI class 600 117(4.61) 82.6(3.25) 63.5(2.50) 127(5.00) 57(2.24) 15.8(0.62) 6.35(0.25) 60(2.36) 4 19(0.75) R13

Processflangesize:25A(1B)FlangeStandardCode

FlangeRatingCode

FlangeRating øD øC øg L T t f m n øh Groovenumber

A 2 ANSI class 300 124(4.88) 88.9(3.50) 69.9(2.75) 129(5.08) 51(2.01) 17.6(0.69) 6.35(0.25) 60(2.36) 4 19(0.75) R16A 4 ANSI class 600 124(4.88) 88.9(3.50) 69.9(2.75) 129(5.08) 57(2.24) 17.6(0.69) 6.35(0.25) 60(2.36) 4 19(0.75) R16P 2 JPI class 300 124(4.88) 88.9(3.50) 70(2.76) 129(5.08) 51(2.01) 17.6(0.69) 6.35(0.25) 60(2.36) 4 19(0.75) R16P 4 JPI class 600 124(4.88) 88.9(3.50) 70(2.76) 129(5.08) 57(2.24) 17.6(0.69) 6.35(0.25) 60(2.36) 4 19(0.75) R16

Page 120: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

120

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Nov. 20, 2019-00

C70SWRemoteMountHygienicDiaphragmSeal(Flushtype)Unit: mm (approx. inch)

F86E.ai

t

Capillarylength

øg

øD

C70SERemoteMountHygienicDiaphragmSeal(ExtendedType)Unit: mm (approx. inch)

F87E.ai

X2

Capillarylength

øg

ødøD

Page 121: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

121<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Nov. 20, 2019-00

C20FWDirectMountFlangedDiaphragmSeal(Flushtype)Unit: mm (approx. inch)

F88E.ai

154(6.06)180(7.09)

184(7.24)210(8.27)

n-øh

øD øC ød*1

øg

72(2.83)

t

øDøC

ød*1

øg

t

Process flange

[For EJXC50A, EJAC50E, and EJXC40A]

25*2

(0.98)

25*2

(0.9

8)

241(

9.49

)

225(

8.86

)[For general use (Stay style code: S)] [For high temperature use (Stay style code: L)]

[For EJXC80A or EJAC80E][For general use] [For high temperature use]

øD øC ød*1

øg

102(4.02)

t

25*2

(0.98)

*1: Indicates inside diameter of gasket surface.*2: 33 mm(1.3 inch) for Diaphragm material code

and Sealing face material code U.

øD øC ødøg

t25*2

(0.98)

øD øC ødøg

t25*2

(0.98)

Page 122: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

122

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Nov. 20, 2019-00

Unit: mm (approx. inch)

Processflangesize:80A(3B)

Flangestandards

code

Flangeratingcode

Flangerating øD øC øg ød tBoltholes

No.(n) Dia.(øh)J A JIS 10K 185(7.28) 150(5.91) 130(5.12) 90(3.54) 18(0.71) 8 19(0.75)J B JIS 20K 200(7.87) 160(6.30) 130(5.12) 90(3.54) 22(0.87) 8 23(0.91)J D JIS 40K 210 (8.27) 170(6.69) 130(5.12) 90(3.54) 32(1.26) 8 23(0.91)A 1 ANSI class 150 190.5(7.50) 152.4(6.00) 130(5.12) 90(3.54) 23.9(0.94) 4 19.1(0.75)A 2 ANSI class 300 209.6(8.25) 168.1(6.62) 130(5.12) 90(3.54) 28.5(1.12) 8 22.4(0.88)A 4 ANSI class 600 209.6(8.25) 168.1(6.62) 130(5.12) 90(3.54) 31.8(1.25) 8 22.4(0.88)P 1 JPI class 150 190(7.48) 152.4(6.00) 130(5.12) 90(3.54) 24(0.94) 4 19(0.75)P 2 JPI class 300 210(8.27) 168.1(6.62) 130(5.12) 90(3.54) 28.5(1.12) 8 22(0.87)P 4 JPI class 600 210(8.27) 168.1(6.62) 130(5.12) 90(3.54) 32.0(1.26) 8 22(0.87)D H DINPN10/16 200(7.87) 160(6.30) 130(5.12) 90(3.54) 20(0.79) 8 18(0.71)D K DINPN25/40 200(7.87) 160(6.30) 130(5.12) 90(3.54) 24(0.94) 8 18(0.71)

Processflangesize:50A(2B)

Flangestandards

code

Flangeratingcode

Flangerating øD øC øg ød tBoltholes

No.(n) Dia.(øh)J A JIS 10K 155(6.10) 120(4.72) 100(3.94) 61(2.40) 16(0.63) 4 19(0.75)J B JIS 20K 155(6.10) 120(4.72) 100(3.94) 61(2.40) 18(0.71) 8 19(0.75)J D JIS 40K 165(6.50) 130(5.12) 100(3.94) 61(2.40) 26(1.02) 8 19(0.75)A 1 ANSI class 150 152.4(6.00) 120.7(4.75) 100(3.94) 61(2.40) 19.1(0.75) 4 19.1(0.75)A 2 ANSI class 300 165.1(6.50) 127.0(5.00) 100(3.94) 61(2.40) 22.4(0.88) 8 19.1(0.75)A 4 ANSI class 600 165.1(6.50) 127.0(5.00) 100(3.94) 61(2.40) 25.4(1.00) 8 19.1(0.75)P 1 JPI class 150 152(5.98) 120.6(4.75) 100(3.94) 61(2.40) 19.5(0.77) 4 19(0.75)P 2 JPI class 300 165(6.50) 127.0(5.00) 100(3.94) 61(2.40) 22.5(0.89) 8 19(0.75)P 4 JPI class 600 165(6.50) 127.0(5.00) 100(3.94) 61(2.40) 25.4(1.00) 8 19(0.75)D H DINPN10/16 165(6.50) 125(4.92) 100(3.94) 61(2.40) 18(0.71) 4 18(0.71)D K DINPN25/40 165(6.50) 125(4.92) 100(3.94) 61(2.40) 20(0.79) 4 18(0.71)

Processflangesize:40A(1.5B)

Flangestandards

code

Flangeratingcode

Flangerating øD øC øg ød tBoltholes

No.(n) Dia.(øh)J A JIS 10K 140(5.51) 105(4.13) 86(3.39) *1 16(0.63) 4 19(0.75)J B JIS 20K 140(5.51) 105(4.13) 86(3.39) *1 18(0.71) 4 19(0.75)J D JIS 40K 160(6.30) 120(4.72) 86(3.39) *1 24(0.94) 4 23(0.91)A 1 ANSI class 150 127(5.00) 98.4(3.87) 86(3.39) *1 17.5(0.69) 4 15.9(0.63)A 2 ANSI class 300 155.4(6.12) 114.3(4.50) 86(3.39) *1 20.6(0.81) 4 22.4(0.88)A 4 ANSI class 600 155.4(6.12) 114.3(4.50) 86(3.39) *1 22.4(0.88) 4 22.4(0.88)P 1 JPI class 150 127(5.00) 98.6(3.88) 86(3.39) *1 17.6(0.69) 4 16(0.63)P 2 JPI class 300 155(6.10) 114.3(4.50) 86(3.39) *1 20.6(0.81) 4 22(0.87)P 4 JPI class 600 155(6.10) 114.3(4.5) 86(3.39) *1 22.5(0.89) 4 22(0.87)

*1: AlwaysuseincombinationwithC10FR(ød=44mm)

Page 123: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

123<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Nov. 20, 2019-00

C20FEDirectMountFlangedDiaphragmSeal(Extendedtype)Unit: mm (approx. inch)

F89E.ai

n-øh

øD øC øAøg

25(0.98) 72(2.83)

t

øDøC

øAøg

25(0

.98)

241(

9.49

)

225(

8.86

)

tX

2

Process flange

[For EJXC50A, EJAC50E, or EJXC40A]

[For general use (Stay style code: S)] [For high temperature use (Stay style code: L)]

[For EJXC80A or EJAC80E][For general use]

[For high temperature use]

øD øC øAøg

øD øC øAøg øD øC øAøg

X2

25(0.98) 102(4.02)tX2

25(0.98)

t

X225(0.98)

154(6.06)

tX2

180(7.09)184(7.24)210(8.27)

Page 124: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

124

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Nov. 20, 2019-00

Unit: mm (approx. inch)

Processflangesize:100A(4B)

Flangestandards

code

Flangeratingcode

Flangerating øD øC øg tBoltholes

øANo.(n) Dia.(øh)

J A JIS 10K 210(8.27) 175(6.89) 155(6.10) 18(0.71) 8 19(0.75) 96±0.5(3.78±0.02)J B JIS 20K 225(8.86) 185(7.28) 155(6.10) 24(0.94) 8 23(0.91) 96±0.5(3.78±0.02)J D JIS 40K 250(9.84) 205(8.07) 155(6.10) 36(1.42) 8 25(0.98) 96±0.5(3.78±0.02)A 1 ANSI class 150 228.6(9.00) 190.5(7.50) 155(6.10) 23.9(0.94) 8 19.1(0.75) 96±0.5(3.78±0.02)A 2 ANSI class 300 254.0(10.00) 200.2(7.88) 155(6.10) 31.8(1.25) 8 22.4(0.88) 96±0.5(3.78±0.02)A 4 ANSI class 600 273(10.75) 215.9(8.50) 155(6.10) 38.1(1.50) 8 25.4(1.00) 96±0.5(3.78±0.02)P 1 JPI class 150 229(9.02) 190.5(7.50) 155(6.10) 24(0.94) 8 19(0.75) 96±0.5(3.78±0.02)P 2 JPI class 300 254(10.0) 200.2(7.88) 155(6.10) 32(1.26) 8 22(0.87) 96±0.5(3.78±0.02)P 4 JPI class 600 273(10.75) 215.9(8.50) 155(6.10) 38.5(1.52) 8 26(1.02) 96±0.5(3.78±0.02)D H DINPN10/16 220(8.66) 180(7.09) 155(6.10) 20(0.79) 8 18(0.71) 96±0.5(3.78±0.02)D K DINPN25/40 235(9.23) 190(7.48) 155(6.10) 24(0.94) 8 22(0.87) 96±0.5(3.78±0.02)

Processflangesize:80A(3B)

Flangestandards

code

Flangeratingcode

Flangerating øD øC øg tBoltholes

øANo.(n) Dia.(øh)

J A JIS 10K 185(7.28) 150(5.91) 130(5.12) 18(0.71) 8 19(0.75) 71±0.5(2.8±0.02)J B JIS 20K 200(7.87) 160(6.30) 130(5.12) 22(0.87) 8 23(0.91) 71±0.5(2.8±0.02)J D JIS 40K 210(8.27) 170(6.69) 130(5.12) 32(1.26) 8 23(0.91) 71±0.5(2.8±0.02)A 1 ANSI class 150 190.5(7.50) 152.4(6.00) 130(5.12) 23.9(0.94) 4 19.1(0.75) 71±0.5(2.8±0.02)A 2 ANSI class 300 209.6(8.25) 168.1(6.62) 130(5.12) 28.5(1.12) 8 22.4(0.88) 71±0.5(2.8±0.02)A 4 ANSI class 600 209.6(8.25) 168.1(6.62) 130(5.12) 31.8(1.25) 8 22.4(0.88) 71±0.5(2.8±0.02)P 1 JPI class 150 190(7.48) 152.4(6.00) 130(5.12) 24(0.94) 4 19(0.75) 71±0.5(2.8±0.02)P 2 JPI class 300 210(8.27) 168.1(6.62) 130(5.12) 28.5(1.12) 8 22(0.87) 71±0.5(2.8±0.02)P 4 JPI class 600 210(8.27) 168.1(6.62) 130(5.12) 32.0(1.26) 8 22(0.87) 71±0.5(2.8±0.02)D H DINPN10/16 200(7.87) 160(6.30) 130(6.30) 20(0.79) 8 18(0.71) 71±0.5(2.8±0.02)D K DINPN25/40 200(7.87) 160(6.30) 130(6.30) 24(0.94) 8 18(0.71) 71±0.5(2.8±0.02)

Extendedlength(X2)

Extendedlengthcode X22 50±0.5(1.97±0.02)4 100±0.5(3.94±0.02)6 150±0.5(5.91±0.02)8 200±0.8(7.87±0.03)

Page 125: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

125<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Nov. 20, 2019-00

C30SWDirectMountHygienicDiaphragmSeal(FlushType)Unit: mm (approx. inch)

F90E.ai

tS

øD

øg

t

øg

CF

øD

[For EJXC50A, EJAC50E, and EJXC40A]

S

Processconnectionstandardscode

Industrystandard/size øD øg S t C F

3 ISO76.1 91(3.58) 76.7(3.02) 97(3.82) 25(0.98) 250(9.84) 266(10.5)4 ISO101.6 119(4.69) 102.5(4.04) 97(3.82) 25(0.98) 250(9.84) 266(10.5)

[ForEJXC80AandEJAC80E]S

t

øD

øg

F91E.ai

ProcessConnectionStandardsCode

IndustryStandard/Size øD øg S t

2 ISO51 64(2.52) 51.6(2.03) 174(6.85) 20(0.79)3 ISO76.1 91(3.58) 76.7(3.02) 179(7.05) 25(0.98)4 ISO101.6 119(4.69) 102.5(4.04) 179(7.05) 25(0.98)

Page 126: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

126

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Nov. 20, 2019-00

C30SEDirectMountHygienicDiaphragmSeal(ExtendedType)Unit: mm (approx. inch)

F92E.ai

18 (0.7

1)

øD

øg

90(3.54)

X2

øDød

øg

259(

10.2

)

243(

9.57

)

X2

18(0.71)

ød

[For EJXC50A, EJAC50E, and EJXC40A]

[ForEJXC80AandEJAC80E]172(6.77)

X2

øD

øg

18(0.71)

ød

F93E.ai

ProcessConnectionStandardsCode

IndustryStandard/Size øD ød øg

2 ISO51 64(2.52) 50.8(2.00) 51.6(2.03)3 ISO76.1 91(3.58) 72(2.83) 77.4(3.05)4 ISO101.6 119(4.69) 101.6(4.00) 102.5(4.04)

ExtendedLength(X2)ExtendedLength

Code X2

2 52(2.05)4 102(4.02)

Processconnectionstandardscode

Industrystandard/size øD ød øg

3 ISO76.1 91(3.58) 72(2.83) 77.4(3.05)4 ISO101.6 119(4.69) 101.6(4.00) 102.5(4.04)

Extendedlengthcode X22 52 (2.05)4 102 (4.02)

Page 127: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

127<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Nov. 20, 2019-00

C10FRFlushingConnectionRingUnit: mm (approx. inch)

*1: Indicates inside diameter of gasket contact surface.*2: Flushing connection ring.

112(

4.41

)øg

112(

4.41

)øg

MK

*2

Straight type (raised face)Reducer type (raised face)

Straight type (ring type joint)

K

For flange size 80A (3B) and 50A (2B)

For flange size 40A (1 1/2B)

For flange size 80A (3B) and 50A (2B)

Straight type(raised face)

Reducer type(raised face)

Straight type(ring type joint)

ød*1

ød*1

ød*1

Spiral gasket Groove number

*2

Spiral gasket

F94E.ai

Spiralgasketsize80A (3B) ø100×ø120×t4.5(ø3.94×ø4.72×t0.18)50A (2B) ø70×ø90×t4.5(ø2.75×ø3.54×t0.18)

40A(11/2B) ø60×ø75×t4.5(ø2.36×ø2.95×t0.18)

Code SizeGroovenumberSealingface

ProcessConnection

sizeFlange

pressurerating øg ød K M

F3 130 (5.12) 90 (3.54) 27 (1.06) 53 (2.09) 2 100 (3.94) 61 (2.40) 27 (1.06) 53 (2.09) 8 86 (3.39) 44 (1.73) 30 (1.18) 47 (1.85)

J3

2,4 156 (6.14) 90 (3.54) 40 (1.57) R315 147 (5.79) 90 (3.54) 40 (1.57) R316 169 (6.65) 90 (3.54) 40 (1.57) R35

22,4 110 (4.33) 61 (2.40) 40 (1.57) R235,6 125 (4.92) 61 (2.40) 40 (1.57) R24

Page 128: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

128

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Nov. 20, 2019-00

ApplicableProductsTable13-1.ListofApplicableProduct,BothsideDiaphragmSealType(DifferentialPressureTransmitterEJXC80A,

EJAC80E)UppercaseshowsProductmodel,andlowercaseshowsflangesizeorclampsize.

DiaphragmSealSystem Transmitter Diaphragmseal*1 Flushingconnectionring*1*4

High-side Low-side High-side Low-side

Differential Pressure

Transmitter

Both side (High and Low) Diaphragm seal*2

Flanged Seal

Flush Type

EJX110A EJA110E

Measurement span (capsule)

M, H, V

C80FW C80FW C10FR C10FR3-inch (80 mm) 3-inch (80 mm) 3-inch (80 mm) 3-inch (80 mm)

C80FW C80FW C10FR C10FR2-inch (50 mm) 2-inch (50 mm) 2-inch (50 mm) 2-inch (50 mm)

C80FW C80FW C10FR*3 C10FR*3

11/2-inch(40mm) 11/2-inch(40mm) 11/2-inch(40mm) 11/2-inch(40mm)

Inner Diaphragm

Type

(Bundled capillary

type)

C81FA ---- ----1/2-inch(15mm)C81FA ---- ----3/4-inch(20mm)C81FA ---- ----1-inch (25 mm)C81FD ---- ----1/2-inch(15mm)C81FD ---- ----3/4-inch(20mm)C81FD ---- ----1-inch (25 mm)

Inner Diaphragm

Type

(Standard type)

C82FA C82FA ---- ----1/2-inch(15mm) 1/2-inch(15mm)C82FA C82FA ---- ----3/4-inch(20mm) 3/4-inch(20mm)C82FA C82FA ---- ----1-inch (25 mm) 1-inch (25 mm)C82FD C82FD ---- ----1/2-inch(15mm) 1/2-inch(15mm)C82FD C82FD ---- ----3/4-inch(20mm) 3/4-inch(20mm)C82FD C82FD ---- ----1-inch (25 mm) 1-inch (25 mm)

Extended Type

C80FE C80FE ---- ----4-inch (100 mm) 4-inch (100 mm)C80FE C80FE ---- ----3-inch (80 mm) 3-inch (80 mm)

Combination Type

C80FE C80FW ---- C10FR4-inch (100 mm) 3-inch (80 mm) 3-inch (80 mm)

C80FE C80FW ---- C10FR3-inch (80 mm) 2-inch (50 mm) 2-inch (50 mm)

HygienicSeal

FlushType

EJX110A EJA110E

Measurement span (capsule)

M, H, V

C70SW C70SW ---- ----ISO101.6 ISO101.6C70SW C70SW ---- ----ISO76.1 ISO76.1C70SW C70SW ---- ----ISO51 ISO51

ExtendedType

C70SW C70SW ---- ----ISO101.6 ISO101.6C70SW C70SW ---- ----ISO76.1 ISO76.1

CombinationType

C70SW C70SW ---- ----ISO101.6 ISO101.6C70SW C70SW ---- ----ISO76.1 ISO76.1

Page 129: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

129<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Nov. 20, 2019-00

Table13-2.ListofApplicableProduct,Combination(High-side:DirectmountedandLow-side:Remoteseal)DiaphragmSealType(DifferentialPressureTransmitterEJXC80A,EJAC80E)

UppercaseshowsProductmodel,andlowercaseshowsflangesizeorclampsize

DiaphragmSealSystem Transmitter Diaphragmseal*1 Flushingconnectionring*1*4

High-side Low-side High-side Low-side

DifferentialPressure

Transmitter

High-side Direct mounted Diaphragm seal

Low-side Remote Diaphragm seal*2

Flanged Seal

Flush Type

EJX110A EJA110E

Measurement span (capsule)

M, H, V

C20FW C80FW C10FR C10FR3-inch (80 mm) 3-inch (80 mm) 3-inch (80 mm) 3-inch (80 mm)

C20FW C80FW C10FR C10FR2-inch (50 mm) 2-inch (50 mm) 2-inch (50 mm) 2-inch (50 mm)

C20FW C80FW C10FR*3 C10FR*3

11/2-inch(40mm) 11/2-inch(40mm) 11/2-inch(40mm) 11/2-inch(40mm)

Extended Type

C20FE C80FE ---- ----4-inch (100 mm) 4-inch (100 mm)C20FE C80FE ---- ----3-inch (80 mm) 3-inch (80 mm)

CombinationType

C20FE C80FW ---- C10FR4-inch (100 mm) 3-inch (80 mm) 3-inch (80 mm)

C20FE C80FW ---- C10FR3-inch (80 mm) 2-inch (50 mm) 2-inch (50 mm)

Hygienic Seal

Flush Type

EJX110A EJA110E

Measurement span (capsule)

M, H, V

C30SW C70SW ---- ----ISO101.6 ISO101.6C30SW C70SW ---- ----ISO76.1 ISO76.1

Extended Type

C30SE C70SE ---- ----ISO101.6 ISO101.6C30SE C70SE ---- ----ISO76.1 ISO76.1

CombinationType

C30SE C70SW ---- ----ISO101.6 ISO101.6C30SE C70SW ---- ----ISO76.1 ISO76.1

Table13-3.ListofApplicableProduct,CompensationcapillarytypeDiaphragmSealType(DifferentialPressureTransmitterEJXC80A,EJAC80E)

UppercaseshowsProductmodel,andlowercaseshowsflangesize

DiaphragmSealSystem Transmitter Diaphragmseal*1 Flushingconnectionring*1*4

High-side Low-side High-side Low-side

DifferentialPressure

Transmitter

High-side Direct mounted Diaphragm seal

Low-side Remote Diaphragm seal*2

Flanged Seal

Flush Type

EJX110A EJA110E

Measurement span (capsule)

M, H, V

C20FW C80FW C10FR C10FR3-inch (80 mm) 3-inch (80 mm) 3-inch (80 mm) 3-inch (80 mm)

C20FW C80FW C10FR C10FR2-inch (50 mm) 2-inch (50 mm) 2-inch (50 mm) 2-inch (50 mm)

C20FW C80FW C10FR*3 C10FR*3

11/2-inch(40mm) 11/2-inch(40mm) 11/2-inch(40mm) 11/2-inch(40mm)

Extended Type

C20FE C80FE ---- ----4-inch (100 mm) 4-inch (100 mm)C20FE C80FE ---- ----3-inch (80 mm) 3-inch (80 mm)

CombinationType

C20FE C80FW ---- C10FR4-inch (100 mm) 3-inch (80 mm) 3-inch (80 mm)

C20FE C80FW ---- C10FR3-inch (80 mm) 2-inch (50 mm) 2-inch (50 mm)

Page 130: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

130

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Nov. 20, 2019-00

Table13-4a.ListofApplicableProduct,Single(High-sideorLow-side)DiaphragmSealType(DifferentialPressureTransmitterEJXC80A,EJAC80E)

UppercaseshowsProductmodel,andlowercaseshowsflangesize

DiaphragmSealSystem Transmitter Diaphragmseal*1 Flushingconnectionring*1*4

High-side Low-side High-side Low-side

Differential Pressure

Transmitter

High-side Diaphragm seal

Flanged Seal

Flush Type

EJX110A EJA110E

Measurement span (capsule)

M, H, V

C80FW C10FR ----3-inch (80 mm) 3-inch (80 mm)C80FW C10FR ----2-inch (50 mm) 2-inch (50 mm)C80FW C10FR*3

----1.5-inch (40 mm) 1.5-inch (40 mm)

Inner Diaphragm

Type

(Standard Type)

C82FA ---- ----1/2-inch(15mm)C82FA ---- ----3/4-inch(20mm)C82FA ---- ----1-inch (25 mm)C82FD ---- ----1/2-inch(15mm)C82FD ---- ----3/4-inch(20mm)C82FD ---- ----1-inch (25 mm)

Extended Type

C80FE ---- ----4-inch (100 mm)C80FE ---- ----3-inch (80 mm)

Low-side Diaphragm seal

Flanged Seal

Flush Type

C80FW ---- C10FR3-inch (80 mm) 3-inch (80 mm)

C80FW ---- C10FR2-inch (50 mm) 2-inch (50 mm)

C80FW ---- C10FR*3

1.5-inch (40 mm) 1.5-inch (40 mm)

Inner Diaphragm

Type

(Standard Type)

C82FA ---- ----1/2-inch(15mm)

C82FA ---- ----3/4-inch(20mm)

C82FA ---- ----1-inch (25 mm)

C82FD ---- ----1/2-inch(15mm)

C82FD ---- ----3/4-inch(20mm)

C82FD ---- ----1-inch (25 mm)

Extended Type

C80FE ---- ----4-inch (100 mm)

C80FE ---- ----3-inch (80 mm):withprocessconnector(RefertoDiaphragmSealSystemModelCode)

Page 131: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

131<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Nov. 20, 2019-00

Table13-4b.ListofApplicableProduct,Single(High-sideorLow-side)DiaphragmSealType(DifferentialPressureTransmitterEJXC80A,EJAC80E)

UppercaseshowsProductmodel,andlowercaseshowsflangesizeorclampsize

DiaphragmSealSystem TransmitterDiaphragmseal*1 Flushingconnectionring*1*4

High-side Low-side High-side Low-side

DifferentialPressure

Transmitter

High-side Diaphragm seal

Hygienic Seal

Flush Type

EJX110A EJA110E

Measurement span (capsule)

M, H, V

C70SW ---- ----

ISO101.6C70SW

---- ----ISO76.1C70SW

---- ----ISO51

Extended Type

C70SE ---- ----

ISO101.6C70SE

---- ----ISO76.1

Low-side Diaphragm seal

Hygienic Seal

Flush Type

C70SW

---- ----ISO101.6

C70SW

---- ----ISO76.1

C70SW

---- ----ISO51

Extended Type

C70SE

---- ----ISO101.6

C70SE

---- ----ISO76.1

:withprocessconnector(RefertoDiaphragmSealSystemModelCode)

Table13-5.ListofApplicableProduct,DirectmontedDiaphragmSealType(DifferentialPressureTransmitterEJXC80A,EJAC80E)

UppercaseshowsProductmodel,andlowercaseshowsflangesizeorclampsize

DiaphragmSealSystem TransmitterDiaphragmseal*1 Flushingconnectionring*1*4

High-side Low-side High-side Low-side

DifferentialPressure

Transmitter

High-side Direct mounted Diaphragm seal

Hygienic Seal

Flush Type EJX110A

EJA110E

Measurement span (capsule)

M, H, V

C20FW

C10FR----

3-inch (80 mm) 3-inch (80 mm)C20FW

C10FR

----2-inch (50 mm) 2-inch (50 mm)

C20FW

C10FR*3----

11/2-inch(40mm) 11/2-inch(40mm)

Extended Type

C20FE ---- ----

4-inch (100 mm)C20FE

---- ----3-inch (80 mm)

Hygienic Seal

Flush Type

EJX110A EJA110E

Measurement span (capsule)

M, H, V

C30SW ---- ----

ISO101.6C30SW

---- ----ISO76.1C30SW

---- ----ISO51

Extended Type

C30SE ---- ----

ISO101.6C30SE

---- ----ISO76.1C30SE

---- ----ISO51

Page 132: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

132

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Nov. 20, 2019-00

Table13-6.ListofApplicableProduct,DiaphragmSealType(GaugePressureTransmitterEJXC80A,EJAC80E)UppercaseshowsProductmodel,andlowercaseshowsflangesize

DiaphragmSealSystem TransmitterDiaphragmseal*1 Flushingconnectionring*1*4

High-side Low-side High-side Low-side

Gauge Pressure

Transmitter

High-side Diaphragm seal (Low-side Open to atmosphere)

Flanged Seal

Flush Type

EJX430A EJA430E

Measurement span (capsule)

A, B

C80FW----

C10FR----

3-inch (80 mm) 3-inch (80 mm)C80FW

----C10FR

----2-inch (50 mm) 2-inch (50 mm)

C80FW----

C10FR*3----

1.5-inch (40 mm) 1.5-inch (40 mm)

Inner Diaphragm

Type

(Standard Type)

C82FA---- ---- ----

1/2-inch(15mm)C82FA

---- ---- ----3/4-inch(20mm)

C82FA---- ---- ----

1-inch (25 mm)C82FD

---- ---- ----1/2-inch(15mm)

C82FD---- ---- ----

3/4-inch(20mm)C82FD

---- ---- ----1-inch (25 mm)

Extended Type

C80FE---- ---- ----

4-inch (100 mm)C80FE

---- ---- ----3-inch (80 mm)

Hygienic Seal

Flush Type

EJX430A EJA430E

Measurement

span (capsule)

A

C70SW---- ---- ----

ISO101.6C70SW

---- ---- ----ISO76.1C70SW

---- ---- ----ISO51

Extended Type

C70SE---- ---- ----

ISO101.6C70SE

---- ---- ----ISO76.1

Page 133: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

133<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Nov. 20, 2019-00

Table13-7.ListofApplicableProduct,DiaphragmSealType(GaugePressureTransmitterEJXC81A,EJAC81E)UppercaseshowsProductmodel,andlowercaseshowsflangesize

DiaphragmSealSystem TransmitterDiaphragmseal*1 Flushingconnectionring*1*4

High-side Low-side High-side Low-side

AbsolutePressure

Transmitter

High-side Diaphragm seal (Low-side Open to atmosphere)

Flanged Seal

Flush Type

EJX310A EJA310E

Measurement span (capsule)

M, A, B

C80FW----

C10FR----

3-inch (80 mm) 3-inch (80 mm)C80FW

----C10FR

----2-inch (50 mm) 2-inch (50 mm)

C80FW----

C10FR*3----

1.5-inch (40 mm) 1.5-inch (40 mm)

Inner Diaphragm

Type

(Standard Type)

C82FA---- ---- ----

1/2-inch(15mm)C82FA

---- ---- ----3/4-inch(20mm)

C82FA---- ---- ----

1-inch (25 mm)C82FD

---- ---- ----1/2-inch(15mm)

C82FD---- ---- ----

3/4-inch(20mm)C82FD

---- ---- ----1-inch (25 mm)

Extended Type

C80FE---- ---- ----

4-inch (100 mm)C80FE

---- ---- ----3-inch (80 mm)

Table13-8.ListofApplicableProduct,DirectMountDiaphragmSealType(GaugePressureTransmitterEJXC50A,EJAC50E)

UppercaseshowsProductmodel,andlowercaseshowsflangesize.

DiaphragmSealSystem TransmitterDiaphragmseal*1 Flushingconnectionring*1*4

High-side Low-side High-side Low-side

Direct mounted Diaphragm seal

Flanged Seal

Flush Type

EJX530A EJA530E

Measurement

span (capsule) A, B, C

C20FW----

C10FR----

3-inch (80 mm) 3-inch (80 mm)C20FW

----C10FR

----2-inch (50 mm) 2-inch (50 mm)

C20FW----

C10FR*3

----11/2-inch (40 mm)

11/2-inch (40 mm)

Extended Type

C20FE---- ---- ----

4-inch (100 mm)C20FE

---- ---- ----3-inch (80 mm)

Hygienic Seal

Flush Type

EJX530A EJA530E

Measurement

span (capsule)

A, B

C30SW---- ---- ----

ISO101.6C30SW

---- ---- ----ISO76.1

Extended Type

C30SE---- ---- ----

ISO101.6C30SE

---- ---- ----ISO76.1

Page 134: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

134

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01EN Nov. 20, 2019-00

Table13-9.ListofApplicableProduct,DirectMountDiaphragmSealType(DigitalRemoteSensorEJXC40A)UppercaseshowsProductmodel,andlowercaseshowsflangesize.Forothercombinations,askusforavailability.

DiaphragmSealSystem Transmitter Diaphragmseal*1 Flushingconnectionring*1*4

High-side Low-side High-side Low-sideBoth side (Master and

Slave) Direct mount seal *2

Flanged Seal

Flush Type

EJXC40A

C20FW C20FW C10FR C10FR80A (3B) 80A (3B) 80A (3B) 80A (3B)C20FW C20FW C10FR C10FR50A (2B) 50A (2B) 50A (2B) 50A (2B)C20FW C20FW C10FR*3 C10FR*3

40A (1.5B) 40A (1.5B) 40A (1.5B) 40A (1.5B)

Extended Type

C20FE C20FE ---- ----100A (4B) 100A (4B)C20FE C20FE ---- ----80A (3B) 80A (3B)

Combination Type

C20FE C20FW ---- C10FR100A (4B) 80A (3B) 80A (3B)

C20FE C20FW ---- C10FR80A (3B) 50A (2B) 50A (2B)C20FW Screw Mount C10FR ----80A (3B) 80A (3B)C20FW Screw Mount C10FR ----50A (2B) 50A (2B)C20FW Screw Mount C10FR*3

----40A (1.5B) 40A (1.5B)C20FE Screw Mount ---- ----100A (4B)C20FE Screw Mount ---- ----80A (3B)

Screw Mount C20FW ---- C10FR80A (3B) 80A (3B)

Screw Mount C20FW ---- C10FR50A (2B) 50A (2B)

Screw Mount C20FW ---- C10FR*3

40A (1.5B) 40A (1.5B)

Screw Mount C20FE ---- ----100A (4B)

Screw Mount C20FE ---- ----80A (3B)

Hygienic Seal

Flush Type

C30SW C30SW ---- ----ISO101.6 ISO101.6C30SW C30SW ---- ----ISO76.1 ISO76.1

Extended Type

C30SE C30SE ---- ----ISO101.6 ISO101.6C30SE C30SE ---- ----ISO76.1 ISO76.1

Combination Type

C30SE C30SE ---- ----ISO101.6 ISO101.6C30SE C30SE ---- ----ISO76.1 ISO76.1C30SW Screw Mount ---- ----ISO101.6C30SW Screw Mount ---- ----ISO76.1C30SE Screw Mount ---- ----ISO101.6C30SE Screw Mount ---- ----ISO76.1

Screw Mount C30SW ---- ----ISO101.6

Screw Mount C30SW ---- ----ISO76.1

Screw Mount C30SE ---- ----ISO101.6

Screw Mount C30SE ---- ----ISO76.1

Page 135: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

135<<Contents>> <<Index>>

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation GS 01C25W01-01EN Nov. 20, 2019-00

NotesforCombination*1 Thesuffixcodeswhichislistedintable13-10shouldbeidenticalbetweenFlushType(C80FW,C20FW)and

Flushing Connection Ring (C10FR).

Table13-10.NotesforCombinationofC80FW,C20FWandC10FR

ItemswhichshouldbeidenticalbetweenC80FW,C20FWandC10FR

ProcessconnectionsizeFlange standardsFlange pressure ratingSealingfaceGasketcontactsurface

*2 Thesuffixandoptionalcodeswhichislistedintable13-11through13-17shouldbeidenticalbetweenmasterandslave transmitter.

Table13-11.Remotemountflangeddiaphragmseal

Flush type (C80FW) Innner Diaphragm Type (C82FA, C82FD) Extended type (C80FE) Combinationtype (C80FE+C80FW)

SealfillfluidTransmitter connection typeCapillary lengthCapillary inside diameterDiaphragm materialDiaphragm diameterFlange standardsFlange pressure rating

Table13-12.Directmountflangeddiaphragmseal

Flush type (C20FW) Extended type (C20FE) Combinationtype (C20FE+C20FW)

SealfillfluidTransmitter connection typeCapillary inside diameterDiaphragm materialDiaphragm diameterFlange standardsFlange pressure rating

Table13-13.DirectmountHygienicdiaphragmseal

Flush type (C30SW) Extended type (C30SE) Combinationtype (C30SE+C30SW)

SealfillfluidTransmitter connection typeCapillary inside diameterDiaphragm materialDiaphragm diameterProcessconnectionsizeSealing Face Option

Table13-14.Directmount(highside)andremotemount(lowside)combination,orwithcompensationcapillary

Flange mounted type (C80FW, C80FE, C20FW, C20FE)

SealfillfluidProcessConnectionsizeSealing FaceGasketContactSurfaceDiaphragm MaterialDiaphragm OptionFlange standardsFlange pressure ratingFlange Material

Table13-15.Directmount(highside)andremotemount(lowside)combination,hygienictype

Hygienic type (C70SW, C70SE, C30SW, C30SE)

SealfillfluidProcess Connection StandardsDiaphragm MaterialSealing Face Option

Table13-16.Optionalcode

Flange mounted type (C80FW, C80FE, C20FW, C20FE) Inner Diaphragm Type (C81FA, C81FD, C82FA, C82FD)

Oil-prohibiteduseOil-prohibitedusewith dehydrating treatmentMaterialcertificateTeflonfilm(C80FW,C20FW)

Hygienic type (C30SW, C30SE)

Oil-prohibiteduseMaterialcertificateCertificate:ElectropolishingCertificate:BuffungCertificate:BuffungandElectropolishing

Table13-17.Flushingconnectionring

C10FR

UsageProcessconnectionsizeWetted materialGasket usageGasketsizeGasket material

*3:Whenspecifyingflangesize40A(1.5B),alsospecifytheflushingconnectionringsize40A(1.5B).Structureisreducer type.

*4:Specifyonlywhenaflushingconnectionringisspecified

Page 136: EJXC80A, EJAC80E EJXC81A, EJAC81E EJXC50A, EJAC50E, … · 2020-04-11 · GS 01C25W01-01ENSep. 27, 2018-00 Diaphragm Seal System Diaphragm Seal System consists of gauge pressure or

136

All Rights Reserved. Copyright © 2016, Yokogawa Electric Corporation

<<Contents>> <<Index>>

GS 01C25W01-01ENSubject to change without notice.

Nov. 20, 2019-00

<OrderingInformation>1. Model,suffixcodes,andoptioncodes2. Calibrationrangeandunits:

1) Calibrationrangecanbespecifiedwithrangevaluespecificationsupto5digits(excludinganydecimalpoint)forloworhighrangelimitswithintherangeof-32000to32000.Whenreverserangeisdesignated,specifyLRVasgreaterthanURV.Whensquarerootoutputmodeisspecified,LRVmustbe“0(zero)”.

2) Specifyonlyoneunitfromthetable,‘Factorysetting.’

3. Selectlinearorsquarerootforoutputmodeanddisplay mode.Note:Ifnotspecified,theinstrumentisshippedsetfor

linear mode.4. Displayscaleandunits(fortransmittersequipped

with the integral indicator only) Specifyeither0to100%or‘RangeandUnit’forengineering units scale: Scalerangecanbespecifiedwithrangelimitspecificationsupto5digits(excludinganydecimalpoint)forloworhighrangelimitswithintherangeof-32000to32000.Unitdisplayconsistsof6-digit,therefore,ifthespecifiedscalingunitexcluding‘/’islongerthan6-characters,thefirst6characterswillbedisplayedontheunitdisplay.

5. TagNumber(ifrequired) Specifiedcharacters(upto22characters)areengravedonthestainlesssteeltagplatefixedonthe housing.

6. SOFTWARE TAG Specifiedcharacters(upto32characters)aresetas“Tag”(thefirst8characters)and“Longtag”(32characters)intheamplifiermemory.Usealphanumeric capital letters. Whenthe“SOFTWARETAG”isnotspecified,specified“TAGNO”issetas“Tag”(thefirst8characters)and“Longtag”*1 (22 characters) in the amplifiermemory.

7. Otherfactoryconfigurations(ifrequired) SpecifyingoptioncodeCAwillallowfurtherconfigurationatfactory.Followingareconfigurableitems and setting range. [/CA]1) Descriptor (up to 16 characters)2) Message (up to 30 characters)3)Softwaredamping(0.00to100.00sec)

<FactorySetting>

Tagnumber AsspecifiedinorderSoftwaredamping *1 ‘2.00s’orasspecifiedinorder

Calibrationrangelower range value Asspecifiedinorder

Calibrationrangeupper range value Asspecifiedinorder

Calibrationrangeunits

SelectedfrommmH2O, mmH2O(68°F),mmAq*2, mmWG*2, mmHg, Pa, hPa*2, kPa,MPa,mbar,bar,gf/cm2,kgf/cm2, inH2O, inH2O(68°F),inHg,ftH2O,ftH2O (68°F)orpsi.(Onlyoneunitcanbespecified.)

Display setting Designateddifferentialpressurevaluespecifiedinorder.(%oruserscaledvalue.)

*1: Tospecifytheseitemsatfactory,optioncode/CAisrequired.

*2: NotavailableforHARTprotocoltype.

<MaterialCrossReference>

ASTM JISgrade 316 SUS316grade316L SUS316Lgrade 304 SUS304