16
Contents 4 Precautions for Safe Use ………………………………… The characteristic of Hydrogen Water Generator 2 …… 5 Name of each part unit ………………………………… 6 Product configuration ………………………………… 8 How to unstall before use ………………………………… 10 Installation Overview ………………………………… 11 How to operate the system ………………………………… 12 How to replace filter ………………………………… 13 How to remove remained electrolytic water ………… 14 Trouble Shooting Chart ………………………………… 15 • Specifications ………………………………………………… 16 Certificate of Warranty ………………………………… EGT - 400 User’s Manual Precautions for Safe Use • For the safer use of a product, please make sure to read the following notes carefully

EGT - 400 User’s Manualegtplus.com/wp-content/uploads/2020/03/EGT400.pdf · 2020. 3. 13. · EGT - 400 User’s Manual Precautions for Safe Use • For the safer use of a product,

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: EGT - 400 User’s Manualegtplus.com/wp-content/uploads/2020/03/EGT400.pdf · 2020. 3. 13. · EGT - 400 User’s Manual Precautions for Safe Use • For the safer use of a product,

Contents

4• Precautions for Safe Use

…………………………………

• The characteristic of Hydrogen Water Generator

2……

5• Name of each part unit …………………………………

6Product configuration• …………………………………

8• How to unstall before use …………………………………

10• Installation Overview …………………………………

11• How to operate the system …………………………………

12• How to replace filter …………………………………

13• How to remove remained electrolytic water…………

14• Trouble Shooting Chart …………………………………

15• Specifications …………………………………………………

16Certificate of Warranty• …………………………………

EGT - 400 User’s Manual

Precautions for Safe Use• For the safer use of a product, please make sure to read

the following notes carefully

Page 2: EGT - 400 User’s Manualegtplus.com/wp-content/uploads/2020/03/EGT400.pdf · 2020. 3. 13. · EGT - 400 User’s Manual Precautions for Safe Use • For the safer use of a product,

2

The characteristic of EGT Hydrogen Water Purifier

Generation of High-Concentrated Hydrogen-Rich Water

Slim and Compact Design with LED Lightning

Easy Filter Replacement

NSF/ANSI 42 Recognized Filter Material

Adoption DC 12V for Safety

With system control from automatic control program,hydrogen water with more thana certain concentrationis always provided by controlling generationof hydrogen, dissolution timing,concentration control of hydrogen water etc.(At present, regular concentration of hydrogen(DH) based on sample device: DH 1,000~1,300 ppb)(Unit to product Hydrogen-reduced water with the function of controlling concentration of dissolved hydrogen: Invention patent).

Page 3: EGT - 400 User’s Manualegtplus.com/wp-content/uploads/2020/03/EGT400.pdf · 2020. 3. 13. · EGT - 400 User’s Manual Precautions for Safe Use • For the safer use of a product,

Before using a product, please make sure to read "Precautions for Safe Use" carefully and use it appropriately. • After reading, please keep it in a place where anyone can see at any time. • Appearance may be subject to change without notice in order to improve the quality of a product.

In the event that serious injury or death may occur in violation of instructions given.

In the event that minor injury or product damage in violation of instructions given.

These graphical figures are symbols for calling a user’s attention to anything and operation whichmight cause a hazard.

For the part with these symbols, please read it carefully and follow the instructions to avoid a hazard that may occur.

When using your appliance, always follow basic precautions, including the following.

WARNING

CAUTION

WARNING

Do not attempt to dissemble or operate the device on your own.• It may cause product damage.

Do not grasp dispensing valve, when moving machine.

Do not place anything on the top of machine.

Connect only to a cold water supply.

Make sure not exceed 3 meter water tubing hose from cold water supply anddo not pull down tubing line when

Do not damage product.• Doing so may causes injury or product damage.

Check with your state and local public works department for plumbing andsanitation code.

Do not install where the temperature and humidity are high.

For residential and light commercial use only. Do not use this appliance for other than the intended use.

3

Precautions for Safe Use.

Page 4: EGT - 400 User’s Manualegtplus.com/wp-content/uploads/2020/03/EGT400.pdf · 2020. 3. 13. · EGT - 400 User’s Manual Precautions for Safe Use • For the safer use of a product,

4

Precautions for Safe Use.

CAUTION

Do not wipe with thinners, benzene, alcohol etc.

Please use it in a safe place with no slope.

Do not connect to hot water pipe, only cold water tap line.

Connect only to a cold water supply.

Do not move machine when operating.

Make sure the system is plugged into a live 110 -220 V AC outlet.

Avoid installing the unit where it could be explosed to water or moisture,

other heating system.

If the main body falls in the water or water leak from inside of cabinet, immediately.

If the main body falls in the water or water leak from inside of cabinet, immediately

disconnect the plug and then take it out of water.

When the unit is not in use for a long period of of time. please unplug the unit from

the outlet and shut o� supply valve.

If machine has not been used for long time, run water through it for 5 minutes or

10 liters over.

Filters should be replaced on schedule and do not change filter set position arbitrarily.

Use only factory authorized filters.

Make sure filter replacement time.

Page 5: EGT - 400 User’s Manualegtplus.com/wp-content/uploads/2020/03/EGT400.pdf · 2020. 3. 13. · EGT - 400 User’s Manual Precautions for Safe Use • For the safer use of a product,

5

6

6

7

7

8

8

9

9

Side Panel Fixing Screw

Power Supply

1

5

1

2

3

4

5

Water Spigot

Button Spigot

Side Panel

Drip Tray Grill

Drip Tray

2

3

4

Name of each part of unit

Water Supply Valve

Feed Water Supply

Page 6: EGT - 400 User’s Manualegtplus.com/wp-content/uploads/2020/03/EGT400.pdf · 2020. 3. 13. · EGT - 400 User’s Manual Precautions for Safe Use • For the safer use of a product,

6

• Product configuration

Inside Structure

1

2

3

4

5

6

7

8

9

10

Hydrogen Generator ModuleDevice

Hydrogen Generator ModuleDrain Cap

LED Light

Drip Tray

Water Spigot

Carbon Filter

UF Membrane Filter

PCB Cover

Pressure Regulator(Reducer)Filter Head

5

8

2

1 6 7

4

9 10

3

Page 7: EGT - 400 User’s Manualegtplus.com/wp-content/uploads/2020/03/EGT400.pdf · 2020. 3. 13. · EGT - 400 User’s Manual Precautions for Safe Use • For the safer use of a product,

7

Package content

Filtration

• How to install before use

Please check feed water sources.

Do not use the system on microbiologically unsafe drinking water.

• Pleas set length of tube between the product and RO water tank or water bottle within 1m.

More than 1 meter may result in poor pump performance or reduce water flow.

• When connecting to water bottle, fix it so that the water supply tube is immersed in the bottled

Notice : After finishing installation, please run about 5 liters of the water to flush the system.

water bottle.

Please check the components received against your packing

slip to make sure you have all the parts

Diverter ( Optional )

Tubing (1/4 Inch)

Electric adapter and plug

(AC 100~240V,DC 12V )

User’s manual

Adapter valve

Tube outlet deco ( Optional )

Diverter adapters ( Optional )

Housing material

Filter component

Capacity( Liter/ Gallon)

Dimension

Weight

polypropylene

1,800L/475 gallon 3,600L/951 gallon

67( )×203(H)

Pre Carbon Filter

Filtration

Carbon Block

270g/6lb

UF Membrane Filter

Polysulfone

240g/5lb

1 2

Page 8: EGT - 400 User’s Manualegtplus.com/wp-content/uploads/2020/03/EGT400.pdf · 2020. 3. 13. · EGT - 400 User’s Manual Precautions for Safe Use • For the safer use of a product,

• How to install before use

1. Do not use warm or hot water, as may this damage the machine.

2. Please be sure to turn o� adater valve when connecting water supply.

3. Check for any sign of leakage all tubing connections.

4. Check the tubing line is all straight position.

5. Do not let power cord hanover the edge of table or counter, or touch hot surfaces.

6. Do not operate machine before finishing installation work.

7. Do not install it where the temperature and humidity are high. Keep it in a place it may not

be adversely a�ected by temperature, sunlight, dust, salt, sulfur content, etc.

• Installation Overview

※ For the first time use, please press and hold dispenser and flush 5 liters water over.

Hot

Sink

Cold

Inlet water tubing

Tap water valve

Tap water valve

Adapter valve Adapter valve

8

A typical connection using the included adapter valve is shown in the illustration below.Connect diverter for water supply to cold water pipe and inhale water up to 1/4inch ● Caution - Please be sure to turn o� adapter valve. - Please be sure to connector to a cold water pipe. Firmly push the inlet water tubing onto water inlet collar. Respectively not escape. Screw nut onto the diverter.● Caution. Install a tubing in a correct position. Turn on the adapter valve.Check any sign of leakage all tubing connections.

Hot Cold

Cold water pipe

Adapter valve

Tap water valve(cold pipe)

Inlet water tubing

Sink

Page 9: EGT - 400 User’s Manualegtplus.com/wp-content/uploads/2020/03/EGT400.pdf · 2020. 3. 13. · EGT - 400 User’s Manual Precautions for Safe Use • For the safer use of a product,

9

Connect Water Lines

① Insert the inlet water tubing to water inlet collar located on the rear of the unit.

② Connect another end of tubing to water filter inlet of the adaptor value.

③ Turn on the middle valve for inlet water.

④ Turn on the water supply valve.

• You are now ready to turn the water main back on. As the system fills, check for leaks and make sure that everything is connected properly.• Run the water to flush the system for about 5 minutes. You any notice some carbon dust in the water initally. This is normal and harmless. After flushing the system you should be able to check for clarity of the water in a clear glass.

Feed water supply tube

Close Open

Water supply valve

Adapter valve

• Installation Overview

5 Washer ( Φ37 )

4 Rubber washer ( Φ41.5 )

1 Fixing nut ( Φ 43.5 )

2 Lock clip ( Φ21.5 )

3 Block locating washer ( Φ42 )

7 Tube outlet deco ( Φ11 )

6 Escutcheon plate ( Φ45 )

Tube Outlet Deco Mounting Installation ( Optional )

① Insert base cover and gasket onto mounting bolt on tube outlet de

Insert mounting bolt through the drilled hole in the fixture.

Place washer and lock washer and fixing nut onto the mounting bolt. Position tube outlet decoon fixture, then tighten nut securely.

④ Insert standard tube.

Mounting surface

1

2

3

4

5

6

7

Cold Hot

Sink

Page 10: EGT - 400 User’s Manualegtplus.com/wp-content/uploads/2020/03/EGT400.pdf · 2020. 3. 13. · EGT - 400 User’s Manual Precautions for Safe Use • For the safer use of a product,

10

• Installation Overview

① Measure 3/4” from the ends of tubing ( inlet end) and mark with a pencil. ( Check for roundness, smoothness, cut, nicks, flat spots, and sharp edges.)

② Fitting collar. (If the tubing is removed, re-cut the end, measure, mark and re-insert).③ Tubing must be fully inserted to avoid leaks (To remove tubing, depress and hold white

Push the tubing firmly into each fitting on the manifold until the line is flush with the

collet; pull tubing out to remove).

④ Pull out slightly on tubing to ensure a good seal. Do no pull too hard or it may damage related parts.

⑤ install the other end of the tubing from the inlet side of the manifold to the feed water

Insert plastic tab to ensure quick- connect fitting cannot come undone.

adapter.

② the collet is pushed evenly on all sides. If only one side is pushed, the tubing will not be

Remove plastic tab from fitting.

Push the collet inward and hold with a finger while pulling the tubing out. Make sure

removable.

Making Tubing Connections(Tubing is not performance - tested or certified by NSF)

To Disconnect Tubing :

Tubing correctly cut and connected

end of tubing round and smooth.with no cuts, nicks or flat spots

Incorrect partial engagement

CORRECT INCORRECT

correct full 3/4”

collet (depress to remove tubing)

tubing

Page 11: EGT - 400 User’s Manualegtplus.com/wp-content/uploads/2020/03/EGT400.pdf · 2020. 3. 13. · EGT - 400 User’s Manual Precautions for Safe Use • For the safer use of a product,

11

Push

• How to operate the system

Press button on the top of the product. The button area flashes green

When button is pressed, about 1 cup of hydrogen It will automatically stop after you head out.

※ If you press the button for more than 0.5 seconds. Press as many times as you like and press again Heading stops.

PURE

• How to use (when water is used)

Press button on the top of the product. The button area flashes blue

When button is pressed, about 1 cup of hydrogen It will automatically stop after you head out.

• How to use (when hydrogen water is used)

H2

H2

Push

PURE

Page 12: EGT - 400 User’s Manualegtplus.com/wp-content/uploads/2020/03/EGT400.pdf · 2020. 3. 13. · EGT - 400 User’s Manual Precautions for Safe Use • For the safer use of a product,

12

Shut o� the adapter valve and the Water supply valve.

Make sure the water has been completely drained from system.

Remove screw at the rear of unit and slide the right-hand panel to open cover.

Turn the cartridge to the left (counterclockwise) and pull cartridge straight down to remove it.

Insert new cartridge and turn right.

then fix it with the fixing screw.

Open the water supply valve on the back of the product.

CLOSE

OPEN

CLOSE

OPEN

CLOSE

OPEN

• How to replace filter

Page 13: EGT - 400 User’s Manualegtplus.com/wp-content/uploads/2020/03/EGT400.pdf · 2020. 3. 13. · EGT - 400 User’s Manual Precautions for Safe Use • For the safer use of a product,

13

Remove screw at the rear of unit and slide the right-hand panel to open cover.

Remove the plug from the end of the drain hose on the right side of the electrolyzer. Rotate the hose low enough to allow the water inside the electrolyzer to come out.

※ Storing electrolyzer for a long period without removing water may contaminate the inside of the electrolyzer.

Drain hose

Drain hose

End plug

End plug

Shut o� the adapter valve and the Water supply valve.

Make sure the water has been completely drained from system.

Align the cover with the groove of the body and slide it forward, then fix it with the fixing screw.

End plug

Remove the plug of the T-fitting on the top of the electrolyzer so that the electrolyte is well drained.

If the electrolyte is completely drained, insert the pluginto the drain hose and return it to its original position.Fit the plug that have been removed back to the T- fitting on the top of the electrolyzer.

CLOSE

OPEN

• How to remove remained electrolytic water

Page 14: EGT - 400 User’s Manualegtplus.com/wp-content/uploads/2020/03/EGT400.pdf · 2020. 3. 13. · EGT - 400 User’s Manual Precautions for Safe Use • For the safer use of a product,

※ Check out before requesting help and reporting product failure.※ Before calling customer’s support, check the following and if you still need help, please contact customer support.

・Trouble Shooting Chart

Symptoms Causes Measures to Be Taken

Significantly less watercomes out

Cold water shut o� valve not fully open

Power adapter not fullyinstalled

Power adapter not fullyinstalled

Damaged Blue LED

Fitting and parts are not firmly connected

Filter life is ended or filter is clogged

No lights in the display

Significantly lessHydrogen Rich watercomes out

Water leaks from machine

Bubble in the water

Strange working sound

Water tastes and smell strange

• Make sure all shut o� valves are fully opened

• Replace the filter

• Replace filter

• Shut o� adapter valve and unplugged. Contact your dealer or customer support

Filter life is ended or filter is clogged

Filter life is ended or filter is clogged

Long term unused

If water pressure is low • Is not crimped or bent

• Make sure power adapter is fully installed in back of electronic module and plug is completely installed in outlet

• It is broken. Contact your dealer or customer support. Without led light, water still comes out from spigot

• Make sure power adapter is fully installed in back of electronic module and plug is completely installed in outlet

• Shut o� adapter valve and unplugged. Refer to replace filter and open side panel, Check the leakage point

• Shut o� adapter valve and contact your dealer or customer support

Filter is not sealed properly

Hydrogen Bubble

• Check where the filter is installed and contact your dealer or customer support

• Will disappear soon

Less drain water when Firsttime use

Operating sound, Hydrogengenerating sound

• Drain 10 liters out from machine

• This is normal

• Replace the filter or drain 10 liters out from machine

If water comes out from O outlet hole2

14

Page 15: EGT - 400 User’s Manualegtplus.com/wp-content/uploads/2020/03/EGT400.pdf · 2020. 3. 13. · EGT - 400 User’s Manual Precautions for Safe Use • For the safer use of a product,

15

EGT - 400

100 ~ 240 V, DC 12 V ( 50/60 Hz )

65 W

Quick-Changing Filtration

Pressure Limit 0.2 MPa ~ 0.4 MPa (29 psi ~ 58 psi )

Temperature Limit

119 mm (W) x 363 mm (D) x 340 mm (H)(4.7 inch (W) x 14.3 inch (D) x 13.5 inch(H))

4.5 Kg / 9lbs

5 ℃ ~ 40 ℃ (41 ˚F ~ 104 ˚F )

Hydrogen Rich Water Purifier

Model

119 mm 363 mm

34

0 m

m

Power Requirement(Volt)

Power Consumption

Water Intake

Filtration System

Condition of Feed Water

Product Dimension(W x D x H )

Product Weight

• Specifications

Electronic touch mode

Page 16: EGT - 400 User’s Manualegtplus.com/wp-content/uploads/2020/03/EGT400.pdf · 2020. 3. 13. · EGT - 400 User’s Manual Precautions for Safe Use • For the safer use of a product,

16

1. This product has been passed the comprehensive inspection through the strict quality control at the factory.2. Any defect occurring within the warranty period (one year from the date of purchase) will be free of charge from the dealer or customer service center. However, even if it is within the warranty period, if it is covered by the charged warranty service within this warranty, it will be repaired at a cost.3. If the product malfunctions, please contact the dealer or customer service center.4. When requesting the repair service, the warranty should be presented.5. After purchasing the product, please fill out the form of the warranty and keep it.

Warranty details1. This product will be repaired free of charge in case of any defect in manufacturing or normal operation within the warranty period.2. Even during the warranty period, the following cases will be repaired at a cost. Poor performance and failure occurred after the warranty period has expired Failure due to incorrect or careless handling of consumer Damage caused by intention or negligence of the consumer Failure caused by repair or alteration at a place other than our service center or retail store Failure due to abnormal power supply or faulty of connected equipment In case of the part reaches its end-of-life Failure or defect in the product due to natural disasters If there is no product warranty, or if there is no item on the date of purchase or dealer3. Failure occurs after the expiration of the warranty period will be repaired at a cost.

Serial number

Date of purchase

Dealer

Product name Hydrogen Rich Water Purifier

Certificate of Warranty

Model name EGT-4000

Contact number of dealer

ContactCustomer's

name

Address

TEL : +82-70-4814-4901

FAX : +82-31-8059-2803

Email : [email protected]

1F, 317-59, Seja-ro, Jeongnam-myeon, Hwaseong-si, Gyeonggi-do, Korea, Postal code : 18516

EG Tec