Saniflux Hybrid Diag Nitro Hermetic

PATENTED PATENT PENDING PATENTED PATENTED

Our services

The first A/C system and passenger compartment air purification system combined with a charging station. 2 services in a single station!

Ecotechnics’ patented single-station solution for charging standard, hybrid and electric vehicles, with electric compressors.

Integrated system for diagnosis of electro-mechanical problems on A/C systems, featuring printout of diagnosis and problem solutions.

A/C system leak testing by charging with nitrogen from an external tank (not included) and monitoring pressure drops, with leak alarm.

Collapsible, hermetic cartridges offer full protection against ambient humidity for oil and dye, to guarantee full product efficiency.

Page 4: ECOKLIMA CATALOGUE ON LINE

4

Page 5: ECOKLIMA CATALOGUE ON LINE

5

SanifluxPATENTED

The first air purification system combined with an A/C charging station

The Saniflux system applies ultrasound technology (the same used in aerosols) to passenger compartment air purification and evaporator sanitising, to eliminate annoying odours and infuse a pleasant scent. With the certified Saniflux Liquid in the tank, select the service time from the station menu according to vehicle type (small, medium, large) and start treatment, which may be carried out simultaneously with A/C system charging in full automation.It is possible to directing the flow of nebulised product toward the evaporator, where

bacteria, moulds, and other irritants and allergens may hide.The concentrated, continuous flow guarantees highly-effective and long-lasting bactericide treatment. It works also on stand alone mode.

Page 6: ECOKLIMA CATALOGUE ON LINE

6

HybridPATENT PENDING

Suitable for all hybrid vehicles

The new A/C systems on many latest-generation vehicles, such as hybrid or electric vehicles, are equipped with compressors operated by high-voltage electric

motors containing a specific high-performance electrical insulating oil. Use of other oils may prove dangerous for the operator during system testing if high

voltages are present.Preliminary flushing of the station and the service hoses is recommended before servicing a system of this type. Flushing eliminates the

risk that residues of different (non-insulating) oils may be injected into the A/C system, jeopardising its safety and good operation.The patented Ecotechnics

system permits running this flushing cycle automatically, thanks to the specific lateral couplings, integrated with the station, for connecting the service hoses.

Page 7: ECOKLIMA CATALOGUE ON LINE

7

Diag

1 2

PATENTED

The importance of patented diagnosis in recycling stations

Dynamic DiagnosisWith the pressure and temperature sensors A/C connected to the system, the station conducts analysis with no further need of operator intervention. The station prints a report for each type of diagnosis.

Static DiagnosisThe station uses the pressure and temperature values entered by the operator to perform automatic diagnosis.

ALL THE ADVANTAGES• Easy to use • Fast, accurate diagnosis • Printout of diagnosis and list

of remedial actions • Reliability • Perfect integration with the stations

Diagnosis is an increasingly critical tool for anyone - climate-control specialists and not - wanting to expand their business to include A/C system repair. Ecotechnics offers the following patented solutions:

Page 8: ECOKLIMA CATALOGUE ON LINE

8

NitroNitrogen leak testing

The nitrogen leak testing system is an alternative to traditional leak detection methods (testing during the vacuum phase or dye injection). The advantage offered by nitrogen is that leak

testing may be conducted under pressure with an inert gas. It is useful above all in those cases in which use of a dye is not permissible (for example, in automobile manufacturing).

This system is fully integrated with the Ecotechnics recharging stations to eliminate the need for operator intervention during service. The system prints a leak test report at the end of testing.

Page 9: ECOKLIMA CATALOGUE ON LINE

9

HermeticPATENTED

Hermetic oil and dye cartridges

An A/C station equipped with hermetic cartridges offers the advantage of eliminating contact between the humidity naturally present in ambient air and the oil or dye, which are hygroscopic substances

(that is, substances that easily absorb humidity).The collapsible, accordion-type hermetic cartridges guarantee the high quality of the product charged and protect the internal components of

the station from possible damage from oils and/or dyes of uncertain provenance. Moreover, many vehicle manufacturers recommend use of hermetic cartridges in their authorised repair shops.

STARTINg KIT

Page 10: ECOKLIMA CATALOGUE ON LINE

10

Eck 1800Eck 1800-hfo

Eck 1890Eck 1890-hfo

Type of refrigerant R134a or HFO1234yfService procedure Fully automatic or manualVoltage 220-240V 50/60 HzScale resolution 10 gOil scale resolution 5 gWorking temperature range 11/49°CFilter system 1 filter for humidityVacuum pump 72 litre/min capacity, 0.1 mbar vacuum level (100 L/min for HFO)Compressor 1/3 HPRecovery speed 300 g/min in liquid phaseRefrigerant tank 12 litres, refillableHoses 3 metresOverall size 55 x 60 x 105 cmWeight 80 kgPressure gauges Class 1Bottle pressure gauge Class 2.5Bottle heater Standard equipment

Fully automatic station for recovering, recycling, and recharging R134a or HFO1234yf refrigerant

R134a HFO1234yf

ECK1800 ECK1800-HFO

ECK1890 ECK1890-HFO

Page 11: ECOKLIMA CATALOGUE ON LINE

11

PATENTED

PATENTED

FLuSHiNG kiT

For cleaning A/C systems by flushing with refrigerant.

Automatic Dye Injection With refillable containers and electronic scale.

Thermal PrinterFor a complete, detailed report.

Refrigerant Management Each service is saved in station memory, offering the option of creating a customised archive of all refrigerant transactions.

Automatic Leak Testing The station checks for leaks during the vacuum phase. If leaks are found, it interrupts operation and gives an alarm.

OPTiONSSTANDARD FEATURES

Page 12: ECOKLIMA CATALOGUE ON LINE

12

Eck 3500-upEck 3500-hfo

Eck 3900-upEck 3900-hfo

Fully automatic station for recovering, recycling, and recharging R134a or HFO1234yf refrigerant

Type of refrigerant R134a or HFO1234yfService procedure Fully automatic or manualVoltage 220-240V 50/60 HzScale resolution 10 gOil scale resolution 5 gWorking temperature range 11/49°CFilter system 1 filter for humidity (112 g)Vacuum pump 100 litre/min capacity, 0.1 mbar vacuum levelCompressor 1/3 HPRecovery speed 300 g/min in liquid phaseRefrigerant tank 22 litres, refillable (12 litres for HFO)Hoses 3 metresOverall size 55 x 60 x 105 cmWeight 80 kgThermal printer Standard equipmentPressure gauges Class 1Bottle heater Standard equipment

R134a HFO1234yf

ECK3500-up ECK3500-HFO

ECK3900-up ECK3900-HFO

Page 13: ECOKLIMA CATALOGUE ON LINE

13

PATENTED PATENTEDPATENTED

5” Color Display with icon messaging for easy use.

Automatic HP-LP taps with possibility to select from which port of the a/c system to recover /charge

Nitro Integrated Nitrogen and Nitrogen+Hydrogen leak detection with a connection for external tank

Hybrid (patent pending) Integrated function for service hoses flushing for use with vehicles equipped with electric compressors

Hermetic containers, for new oil and dye.

FLuSHiNG kiT

For cleaning A/C systems by flushing with refrigerant.

GAS iDENTiFiER

controlled by the machine.

SANiFLux

Passenger compartment air purification system.

HERmETiC & REFiLLAbLE

containers, for new oils, and for dye (programmable).

DiAG (only for R134a)

Dynamic diagnosis module.

OPTiONSSTANDARD FEATuRES

Page 14: ECOKLIMA CATALOGUE ON LINE

Black line

Page 15: ECOKLIMA CATALOGUE ON LINE

1 2 3 4

2

4

1

3

Page 16: ECOKLIMA CATALOGUE ON LINE

16

Eck 4000-rEck 4000-me

Eck 4000-hfo

CE

RTIFIED BY

®

TÜVRheinland

Fully automatic station for recovering, recycling, and recharging R134a or HFO1234yf refrigerant

Type of refrigerant R134a or HFO1234yfService procedure Fully automatic or manualVoltage 220-240V 50/60 HzScale resolution 10 gOil scale resolution 5 gWorking temperature range 11/49°CFilter system 1 filter for humidity (112gr)Vacuum pump 100 litre/min capacity, 0.1 mbar vacuvum levelSealed compressor 1/3 HP (SPECIAL COMPRESSOR FOR 4000-ME)Recovery speed 300 g/min in liquid phaseRefrigerant tank 22 litres, refillable (12 litres for HFO)Hoses 3 metresOverall size 55 x 60 x 110 cmWeight 90 kgThermal printer StandardPressure gauges Class 1Display graphic color touch screenBottle temperature sensor IntegratedBottle heater Automatic

R134a HFO1234yf

ECK4000-r ECK4000-HFO

ECK4000-mE specifically designed to work with high temperatures

Page 17: ECOKLIMA CATALOGUE ON LINE

17

PATENTEDPATENTED PATENTED

OPTiONSSTANDARD FEATuRES

Large 7” Color Display with touch-screen icon messaging for easy use.

3 Hermetic & refillable containers for new oils (PAg,POE) and for dye.

uSb port for software update and Wi-Fi/LAN ready

Nitro Integrated Nitrogen and Nitrogen+Hydrogen leak detection with a connection for external tank

Hybrid (patent pending) Flushing of station and service hoses for use with vehicles equipped with electric compressors.

FLuSHiNG kiT

For cleaning A/C systems by flushing with refrigerant.

GAS iDENTiFiER

controlled by the machine.

SANiFLux

Passenger compartment air purification system.

DiAG (only for R134a)

Dynamic diagnosis module.

Page 18: ECOKLIMA CATALOGUE ON LINE

18

Eck twin

Eck twin-proPATENT PENDING

PATENTED

Fully automatic Dual-Gas station for recovering, recycling, and recharging R134a and HFO1234yf refrigerants.

Type of refrigerant R134a and HFO1234yf Service procedure Fully automatic or manualVoltage 220-240V - 50/60 HzScale resolution 10 gOil scale resolution 5 gWorking temperature range 11/49°CFilter system 2 filters for humidity (112 g)Vacuum pump 100 litre/min capacity, 0.1 mbar vacuum levelCompressor Hermetically sealed, 2x12 cc, high pressureRecovery speed 300 g/min in liquid phaseRefrigerant tank 2x12 litres, refillableHoses 2 pairs, each 3 metresOverall size 67 x 62 x 107 cmWeight 110 kgThermal printer Standard equipmentPressure gauges Class 1Display Colour graphic, touch screenBottle temperature sensor IntegratedBottle heater Automatic

R134a and HFO1234yf

ECKtwin

ECKtwin-prO

Page 19: ECOKLIMA CATALOGUE ON LINE

19

PATENTED PATENTED

PATENTED

Nitro Integrated Nitrogen and Nitrogen+Hydrogen leak detection with a connection for external tank (only TWIN-PRO)

Hybrid function, with service hoses flushing, for use with vehicles equipped with electric compressors

4 separate lines for oil and dye with hermetic containers

“Puff free” couplers to save refrigerant with every disconnection (only TWIN-PRO)

FLuSHiNG kiT

For cleaning A/C systems by flushing with refrigerant.

GAS iDENTiFiER

controlled by the machine

SANiFLux

Passenger compartment air purification system.

4 SEPARATE LiNES

for oil and dye with hermetic and refillable containers (programmable)

OPTiONSSTANDARD FEATuRES

Page 20: ECOKLIMA CATALOGUE ON LINE

20

420 mm

510 mmEck land

PRiNTER bOTTLE HEATER FLuSHiNG kiT

OPTiONSSTANDARD FEATuRES

Type of refrigerant R134aService procedure Fully automatic or manualVoltage 220-240 V- 50/60 HzScale resolution 10 g.Oil scale resolution 5 g.Working temperature range 11/49 °CFilter system 1 filter for humidityVacuum Pump 72 l/min, 0,1 mbar vacuum levelCompressor 1/3 HPRecovery speed 300 g./min. in liquid phaseRefrigerant tank 7 l. rechargeableHoses 6 m.Dimensions 510x420x445 mm.Dimensions packaging 600x500x600 mm.Weight 45 kg.Gross weight 50 kg.Thermal printer OptionalManometers Class1Display LCDBottle temperature sensor integratedBottle heater optional

• Strong steel coated casing• Automatic new oil charging• Compact size and easy to

transport• Large manometers

easy to read• Manual discharge of non-

condensable gases• Automatic service alarm

• Integrated database allowing the user to enter new vehicle models

• Flushing software• Automatic internal tank refilling• Refrigerant management• guided leak test• Scale protection with

an easy lock

Fully automatic station for recovering, recycling, and recharging R134a refrigerant for agricultural and earth moving vehicles

TROLLEy (OPTiON) 540x440x500 mm, 11 kg

Page 21: ECOKLIMA CATALOGUE ON LINE

21

Eck bus

Eck bus-proPATENTED

Fully automatic station for recovering, recycling, and recharging R134a refrigerant, for use with buses and industrial vehicles.

Automatic Leak Testing The station checks for leaks during the vacuum phase. If leaks are found, it interrupts operation and gives an alarm.

Automatic Discharge (PATENT PENDING) of non-condensable gases via solenoid valves, with tank temperature and pressure sensors.

Gear Pump for refrigerant charging.

FLuSHiNG kiT

For cleaning A/C systems by flushing with refrigerant.

Features identical to ECK BUS-PRO but:

➜ without gear pump

➜ with automatic tank heater

Type of refrigerant R134aService procedure Fully automatic or manualVoltage 220-240V - 50/60 HzScale resolution 10 gOil scale resolution 5 gWorking temperature range 11/49°CFilter system 2 filters for humidityVacuum pump 170 litre/min capacity, 0.1 mbar vacuum levelCompressor Hermetically sealed, 21 cc, high pressureGear pump 1 kg/min capacityRefrigerant tank 40 litres, refillableHoses 6 metresOverall size 80 x 120 x 115 cmWeight 140 kgThermal printer Standard equipmentDisplay LCDPressure gauges Class 1

OPTiONSSTANDARD FEATuRES

Page 22: ECOKLIMA CATALOGUE ON LINE

22

AEK177

4x 2x

Leak Detection Products & ConsumablesAEK203 - Cobra kit HDLeak detector kit for A/C circuitsincluding: goggles,UV lamp, hermeticdye cartridge(55 ml), injector

AEK107-3 - Electronic LEAK DETECTOR: one instrument for identifying all halogen gases, including CFC, HCFC, HFC.

AEK177 - Electronic LEAK DETECTOR: one instrument for identifying R134a, HFO1234yf and Hydrogen.

AEK145 Cobra lamp + goggles

AEK207- A Manual oil injector kit for R134a

AEK207-B Manual oil injector kit for HFO1234YF

AEK203-C-5 Box of 5 hermetic cartridges of dye (55 ml)AEK203-H-C Box of 5 hermetic cartridges of dye for electric compressors (55 ml)AEK204-H-5 Box of 5 hermetic cartridges of oil for electric compressors (55 ml)

AEK222-1 - SANIFLUX LIQUID1000-ml bottle

OiL

STAR

TiN

G k

iTD

yE

Refrigerant Code Bottle Type Viscosity Q.ty Conf. Compressor Type

R134a

AEK251-N-6 Hermetic Non Refillable PAg46 125 ml. 6 PCS Mechanical

AEK250-6 Hermetic Non Refillable PAg46 270 ml. 6 PCS Mechanical

AEK255-6 Hermetic Non Refillable PAg100 270 ml. 6 PCS Mechanical

AEK250-N-6 Hermetic Non Refillable PAg46 270 ml. 6 PCS Mechanical

AEK255-N-6 Hermetic Non Refillable PAg100 270 ml. 6 PCS Mechanical

AEK280-6 Plastic Bottle PAg46 250 ml. 6 PCS Mechanical

AEK281-6 Plastic Bottle PAg100 250 ml. 6 PCS Mechanical

AEK283-6 Plastic Bottle POE100 250 ml. 6 PCS Electrical

HFO1234yf

AEK265-6 Hermetic Non Refillable PAg100 270 ml. 6 PCS Mechanical

AEK266-N-6 Hermetic Non Refillable PAg100 125 ml. 6 PCS Mechanical

Universal R134a & HFO1234yf

AEK276-6 Plastic Bottle PAg46 250 ml. 6 PCS Mechanical + Electrical

AEK275-6 Plastic Bottle PAg100 250 ml. 6 PCS Mechanical + Electrical

R134a AEK126-3-6 Hermetic Non Refillable 125 ml. 6 PCS Mechanical

HFO1234yf AEK270-6 Hermetic Non Refillable 125 ml. 6 PCS Mechanical

R134a AEK126-N-6 Hermetic Non Refillable 125 ml. 6 PCS Mechanical

HFO1234yf AEK270-N-6 Hermetic Non Refillable 125 ml. 6 PCS Mechanical

Universal R134a & HFO1234yf

AEK290-6 Plastic Bottle 250 ml. 6 PCS Mechanical + Electrical

R134a AEK310 4 x AEK251-N (PAg46 oil - 125 ml) + 2 x AEK 126-N (Dye - 125 ml)

HFO1234yf AEK311 4 x AEK 266-N (PAg100 oil - 125 ml) + 2 x AEK 270-N (Dye - 125 ml)

R134a AEK312 4 x AEK 280 (PAg46 oil - 250 ml) + 2 x AEK 290 (Dye - 250 ml)

HFO1234yf AEK313 4 x AEK 276 (PAg46 oil - 250 ml) + 2 x AEK 290 (Dye - 250 ml)

Page 23: ECOKLIMA CATALOGUE ON LINE

23

+

A/C Accessories

AEK302 - ELECTRONIC SCALE- LCD display - Max capacity: 100 kg- Resolution: 10 g- Charging accuracy: ± 10 g- Working temperature: -10°C / +50°C

XK184.000000 - EASYRECRefrigerant recovery machine- For use with all refrigerants- Compressor type: oilless- Air cooled- For use with gas and liquid refrigerant- Recovery rate (vapour): 17 kg/h- Recovery rate (liquid): 50 kg/h- Recovery rate (push-pull): 240 kg/h

AEK304 - Universal nitrogen leak detection kit with nitrogen-hydrogen bottle (950ml)

AEK305 - Nitrogen + H2 bottle (950ml)

XK184.000039 EASYREC PLUSIdentical to EASYREC with carry case for R12/R134a hoses and couplings

AEK102-N7-R5 Set of bypass adapters for AEK 102-N12 flushing kit

TUB1149 Low-pressure service hose, 6 m

TUB1148 High-pressure service hose, 6 m

CNT4012 40 - litre tank for R134a, R22, R404a, R507, R407C

AEK102-N7-R6 Pair of universal bus adapter disks for AEK 102-N12 flushing kit

AEK120-E Digital thermometer

AEK211 Special quick-connect coupling

AEK102-N7-R3 Set of 5 filters for AEK 102-N12 flushing kit

Refillable and hermetic containers 260ml

GRCNT 16

GRCNT 17

GRCNT 18

GRCNT 19

AEK318 fitting for Dupont bottleAEK319 fitting for Honeywell bottle

AEK221 Laser thermometer

AEK109A High-pressure terminal valve

AEK109B Low-pressure terminal valve

AEK116-1 ACME hose reducer fitting for tank

AEK220 Digital thermometer with probe

KITDB003.14 2014 Data Base updateAEK303

Digital vacuum meter: 0-12000 micron range

SCH8182 USB-RS232 adapter for downloading station data to a USB memory key

AEK224-A HP “puff free” coupler for R134aAEK224-B LP “puff free” coupler for R134a

AEK218-A HP “puff free” coupler for HFOAEK218-B LP “puff free” coupler for HFO

SCH8183 2014 Data Base update

AEK317 double valve-extractor screwdriver

Page 24: ECOKLIMA CATALOGUE ON LINE

Ecotechnics S.p.AVia L. Longo, 21/23

50019 Sesto F.no (FI)Tel. +39 055 4207372Fax +39 055 4217972

www.ecotechnics.comemail: [email protected] 02

/201

4S

TU

DIO

Mir

anna

lti

● ● ● – – ● ● ● ●

● ● ● ● – ● ● ● ●

● ● ● ● ● ● ● ● ●

● ● ● ● ● ● ● ● ●

LCD a CoLor De 5” táCtiL 7’’ LCD LCD LCD a CoLor De 5” táCtiL 7’’ táCtiL 7’’

– ● – – – – ● ● –

● – – ● ● ● – – –

– ❍ ● – – – ❍ ❍ ●

1+1 1+1 2+1 1+1 1+1 1+1 1+1 2+2 2+1

– – ● – – – – – ●

– – – / ● – – – – – –

– ● ● – – – ● ● ●

– ● ● ● – – ● ● ●

– – – – / ● – – – – –

● ● ● / – ● ● ● ● ● ●

● ● ● ● ● ● ● ● ●

– ❍ ❍ – – – ❍ ❍ ❍

– ❍ ❍ – – – ❍ ❍ ❍

– ● ● – – – ● ● ●

– ● ● – – – ● – / ● ●

– ❍ ❍ – – – – – –

● ● ● ● ❍ ● ● ● ●

● ● ● ● / – ❍ ● ● ● ●

● ● ● ● ❍ ● ● ● ●

❍ ❍ ❍/ – ❍ ❍ ❍ ❍ ❍ ❍

ECK

1890

EC

K 18

00

ECK

3900

-UP

ECK

3500

-UP

ECK

4000

-R

ECK

4000

-ME

ECK

BU

S

ECK

BU

S-PR

O

ECK

LAN

D

ECK

1890

-HFO

EC

K 18

00-H

FO

ECK

3900

-HFO

EC

K 35

00-H

FO

ECK

TWIN

EC

K TW

IN-P

RO

ECK4

000-

HFO

R134a HFO1234yf

MaDe in iTaly

INFORMATION REgARDINg DIMENSIONS, DATA, MODELS, AND COLORS IS NOT BINDINg. ECOTECHNICS RESERVES THE RIgHT TO MAKE ANY MODIFICATIONS DEEMED NECESSARY. THE PRODUCTS ARE NOT COVERED BY ANY OTHER EXPRESS OR IMPLICIT WARRANTIES.

images shown may include higher specification accessories.

● STANDARD EQUIPMENT – NoT AvAIlAblE ❍ oPTIoNAl

HIgH PRECISION

AUTOMATIC LEAK CHECK

REFRIgERANT MANAgEMENT

DATA BASE

DISPLAY

HERMETIC CONTAINERS

REFILLABLE CONTAINERS

HERMETIC & REFILLABLE CONTAINERS

OIL/DYE CONTAINERS

STATUS LIgHT

HIgH AMBIENT TEMPERATURES FEATURES

AUTOMATIC TAPS

AUTOMATIC AIR PURgE

gEAR PUMP

FLUSHINg SW

USB PORT

gAS IDENTIFIER

SANIFLUX

HYBRID

NITRO

DIAg

PRINTER

BOTTLE HEATER

AUTOMATIC DYE

FLUSHINg KIT