Upload
others
View
18
Download
1
Embed Size (px)
Citation preview
www.eae.com.tr/EN
E-LINEMK
IEC 61439-6 T Es
EAE Elektrik A.Ş.Akcaburgaz Mahallesi,
3114. Sokak, No:10 34522Esenyurt-Istanbul-TURKEY
Tel: +90 (212) 866 20 00Fax: +90 (212) 886 24 20
Busbar Systems 100-160-225 A
Catalogue 05-Eng. / Rev 10 1.000 pcs. 31/07/2019A.C.E.
EAE has full right to make any revisions or changes on this catalogue without any prior notice.
Please visit our website for the updated version of our catalogues.www.eae.com.tr/EN
9001140011800127001
ISO Mİ / AR NE AL GM EE MT
S Eİ NS T M Sİ YT SE TN EÖ MY S
E-LINEMK
Introduction
Order Code System
Technical Characteristics
Standard Components
Special Straight Length
Flexible Elbow
Expansion Module
Feeder Boxes
Tap-Off Boxes
Fixing Elements
MK Joint Installation
MK Tap-Off Box Installation
Directive
Product Overview
Certificate
Project Design Form
E-LINE MK
Please visit our website for the updated version of our catalogues.www.eae.com.tr/EN
CONTENTS
2
4
5
6
7
8
9
10
13
18
20
21
23
24
25
26
The E-Line MK prefabricated busbar trunking
system is used as a vertical and horinzontal
electrical energy distribution system in premises
where there is a need for distribution of energy
with ratings of 100A-160A-225A. The busbar
housing is manufactured from RAL 7038 epoxy
painted galvanized sheet metal.
E L E K T R İ K
E MKLINE
2 3
3000
200 600 600 600 600 400
200600600600600400
Posibility to get up to 80A energy by using tap-off
boxes. Interlock mechanizm cuts the energy before
opening the lid. Tap-off boxes can be installed
safely and easly without additional tool.
When either the tapping outlet dust cover, or the
tapping box is de-energised (Lid open) the minimum
degree of protection IP2X is maintained. This
preventing accidential contact with live contacts.
Personell SafetyThe mounting of units does not require any special
expertise. Depending on the structure and shape of
the building, all necessary accessories can be easily
mounted either to the ceilling or wall. "Fast and Easy
Mounting" means rapid commissioning of the system.
Fast and Easy Mounting
General Characteristics
Broken Nut
Special Block Joint
Thanks to the double-head nut, the need for a torque
wrench is eliminated. Since the first head of the nut
tightened with an ordinary wrench is automatically
broken. The first head of the nut will be broken at
20Nm.
Tin Plated Joint Contacts
Busbar joint contacts are tin plated. The tin plating
reduce contact resistance and eliminates
overheatings at contact points.
Tap-off Boxes are manufactured of
selfextinguishing (UL V0) and halogen-free plastic
material.
Self-Extinguishing Material for Tap-off Boxes
Tap-off points are protected by IP55 covers againts
water and dust. These covers are fixed to the busbar
housing by hinges and single point locker system.
Hinged and Locked IP55 Covers
Vertical and horizontal elbow and dilatation modules
are solved by using a single module. Horizontal or
vertical elbows at desired angle can be easily
accomplished. They are also used safety at the
passages of buildings, thanks to their flexibility in
every direction.
Copper and aluminium conductors are protected
againts corrosion by continious tin plating at entire
length. This application increase the life time of
conductors and reduce contact resistances.
Full Size Tin Plated Conductors
Special Flexible Elbows and ExpansionModules
Provision of a total of 10 Plug-in tapping points on
both sides of the busbar are provided as a standard
feature.
10 Current Feeding Windows of Every Length
E-Line MK allows application of conductor
configurations with options below.
a- 4 Conductor...........................
b- 5 Conductor...........................
c- 5 Conductor clean earth
: L1,L2,L3,N,PE(Housing)
: L1,L2,L3,N,PE,PE(Housing)
: L1,L2,L3,N,CPE,PE(Housing)
Plug-in Points
Conductor Configuration
The E-Line MK prefabricated busbar trunking
system is used as a vertical and horinzontal
electrical energy distribution system in premises
where there is a need for distribution of energy
with ratings of 100A-160A-225A. The busbar
housing is manufactured from RAL 7038 epoxy
painted galvanized sheet metal.
E L E K T R İ K
E MKLINE
2 3
3000
200 600 600 600 600 400
200600600600600400
Posibility to get up to 80A energy by using tap-off
boxes. Interlock mechanizm cuts the energy before
opening the lid. Tap-off boxes can be installed
safely and easly without additional tool.
When either the tapping outlet dust cover, or the
tapping box is de-energised (Lid open) the minimum
degree of protection IP2X is maintained. This
preventing accidential contact with live contacts.
Personell SafetyThe mounting of units does not require any special
expertise. Depending on the structure and shape of
the building, all necessary accessories can be easily
mounted either to the ceilling or wall. "Fast and Easy
Mounting" means rapid commissioning of the system.
Fast and Easy Mounting
General Characteristics
Broken Nut
Special Block Joint
Thanks to the double-head nut, the need for a torque
wrench is eliminated. Since the first head of the nut
tightened with an ordinary wrench is automatically
broken. The first head of the nut will be broken at
20Nm.
Tin Plated Joint Contacts
Busbar joint contacts are tin plated. The tin plating
reduce contact resistance and eliminates
overheatings at contact points.
Tap-off Boxes are manufactured of
selfextinguishing (UL V0) and halogen-free plastic
material.
Self-Extinguishing Material for Tap-off Boxes
Tap-off points are protected by IP55 covers againts
water and dust. These covers are fixed to the busbar
housing by hinges and single point locker system.
Hinged and Locked IP55 Covers
Vertical and horizontal elbow and dilatation modules
are solved by using a single module. Horizontal or
vertical elbows at desired angle can be easily
accomplished. They are also used safety at the
passages of buildings, thanks to their flexibility in
every direction.
Copper and aluminium conductors are protected
againts corrosion by continious tin plating at entire
length. This application increase the life time of
conductors and reduce contact resistances.
Full Size Tin Plated Conductors
Special Flexible Elbows and ExpansionModules
Provision of a total of 10 Plug-in tapping points on
both sides of the busbar are provided as a standard
feature.
10 Current Feeding Windows of Every Length
E-Line MK allows application of conductor
configurations with options below.
a- 4 Conductor...........................
b- 5 Conductor...........................
c- 5 Conductor clean earth
: L1,L2,L3,N,PE(Housing)
: L1,L2,L3,N,PE,PE(Housing)
: L1,L2,L3,N,CPE,PE(Housing)
Plug-in Points
Conductor Configuration
A 16 5 7 -
IP 55 5
MK
4
5
7
T DSS
STD
X
FD
DT
B1
B2
BO
E L E K T R İ K
E MKLINE
4
Order Code SystemBUSBAR TYPE
CONDUCTOR TYPE
PROTECTION DEGREE
COMPONENT
BUSBAR CURRENT
CONDUCTOR CONFIGURATION
Components
Busbar Type
Aluminium ACopper C
Conductor Type
Busbar Current
Protection Degree
CodeNumber of
Conductors
Conductor Configuration
Configuration
L1,L2,L3,N,PE(Housing)
L1,L2,L3,N,PE,PE(Housing)
L1,L2,L3,N,CPE,PE(Housing)
4 wire
5 wire
5 wire (Clean Earth)
Standard Length
Special Length
Flexible Elbow
Expansion Unit
Feeder Box 1
Feeder Box 2
Central Feeder Box
10
16
22
10
16
22
100
160
225
100
160
225
BusbarRated Current
Aluminium
Copper
Code
E L E K T R İ K
E MKLINE
In A
Ui
Ue
f
3
IP
V
V
Hz
55
Icw
Ipk
Icw
Ipk
Icw
Ipk
Icw
Ipk
kA(rms)
kA
kA
kA
kA
kA
kA
kA
R 20
R
X
Z
Z20
mW/m
mW/m
mW/m
mW/m
mW/m
R/ortPh
RN
RPE
RCPE
W/m
mW/m
mW/m
mW/m
mW/m
mm²
mm²
mm²
mmxmm
kg/m
kg/m
Z(0) b20phN
Z(0) b20phPE
Z(0) b20phCPE
Z(0) bphN
Z(0) bphPE
Z(0) bphCPE
mW/m
mW/m
mW/m
mW/m
mW/m
mW/m
Rb20phph
Rb20phN
Rb20phPE
Rb20phCPE
Rbphph
RbphN
RbphPE
RbphCPE
Xbphph
XbphN
XbphPE
XbphCPE
mW/m
mW/m
mW/m
mW/m
mW/m
mW/m
mW/m
mW/m
mW/m
mW/m
mW/m
mW/m
Plug-in Busbar IK07
IEC 61439-6, TS EN 61439-6, IEC 61439-1,
5
Technical Characteristics
L1,L2,L3,N
Copper Conductor (MKC)Aluminium Conductor (MKA)
Standards
Busbar Weight (4 Conductors)
Reactance (Independent from temperature)
Busbar Weight (5 Conductors)
PE (5 Conductors)
Rated Isolation Voltage
Max. Rated Operational Voltage
Rated Frequency
Pollution Degree
Protection Degree
External Mechanical Impacts (IK Code)*
Rated Short-time Withstand Current (1s)
Rated Short-time Withstand Current for Neutral Conductor (1s)
Rated Short-time Withstand Current for PE Conductor (1s)
Rated Peak Withstand Current
Rated Peak Withstand Current for Neutral Conductor
Rated Peak Withstand Current for PE Conductor
Zero-sequence Impedance
Resistance at a conductor temperature of 20 °C
Reactance (Independent from Temperature)
Rated Power Loss at 35 °C
Conductor Dimensions
DC Resistance at a conductor temperature of 20 °C for Phases
DC Resistance at a conductor temperature of 20 °C for Neutral
DC Resistance at a conductor temperature of 20 °C for PE
Zero-sequence impedance at a conductor temperature of 20 °C
Resistance at a conductor temperature of 20 °C
Resistance at a conductor temperature of 20 °C
Resistance at a conductor temperature of 20 °C
Resistance at an ambient air temperature of 35 °C
Zero-sequence impedance at a conductor temperature of 20 °C
Zero-sequence impedance at an ambient temperature of 35 °C
Zero-sequence impedance at an ambient temperature of 35 °C
Resistance at an ambient air temperature of 35 °C
Positive and negative sequence impedances at an ambient air temperature of 35 °C
Positive and negative sequence impedances at a conductor temperature of 20 °C
Busbar Code
Rated Current
SECTIONS
MEAN FAULT-LOOP CHARACTERISTICS
Resistances and Reactances
MEAN PHASE CONDUCTOR CHARACTERISTICS AT RATED CURRENT In
PE (Sheet Metal)
Rated Short-time Withstand Current for CPE Conductor (1s)
Rated Peak Withstand Current for CPE Conductor
Reactance (Independent from temperature)
Reactance (Independent from temperature)
Reactance (Independent from temperature)
DC Resistance at a conductor temperature of 20 °C for CPE
Zero-sequence impedance at a conductor temperature of 20 °C
Zero-sequence impedance at an ambient temperature of 35 °C
Resistance at a conductor temperature of 20 °C
Resistance at an ambient air temperature of 35 °C
Resistance at an ambient air temperature of 35 °C
Resistance at an ambient air temperature of 35 °C
* Joint weight is included rated 1/3 of the weight of the joint in the indicated weights per meter.
160100
10 1016 16 2222
100 160 225225
690
690
50
6
10,2
3,6
5,4
3,6
5,4
3,6
5,4
6
10,2
3,6
5,4
3,6
5,4
3,6
5,4
3,5
5,25
2,1
3,15
2,1
3,15
2,1
3,15
3,5
5,25
2,1
3,15
2,1
3,15
2,1
3,15
6
10,2
3,6
5,4
3,6
5,4
3,6
5,4
12,5
25
7,5
12,75
7,5
12,75
7,5
12,75
0,391
0,506
0,138
0,525
0,415
37,6
0,378
0,377
0,885
0,378
0,299
0,411
0,107
0,425
0,318
62,4
0,306
0,317
0,885
0,315
0,640
0,787
0,154
0,802
0,658
23,4
0,608
0,603
0,885
0,609
0,747
0,942
0,191
0,961
0,771
27,7
0,699
0,702
0,885
0,702
0,405
0,535
0,158
0,558
0,435
40,3
0,389
0,386
0,885
0,385
0,251
0,341
0,135
0,367
0,284
49,7
0,242
0,241
0,885
0,242
47,25
47,25
198
4,5x10,5
2,35
2,50
47,25
47,25
198
4,5x10,5
3,30
3,70
27
27
198
4,5x6
2,75
3,00
76,50
76,50
198
4,5x17
2,70
2,90
108,00
108,00
198
4,8X22,5
,3 23
,4 08
76,50
76,50
198
4,5x17
4,50
5,20
2,801
3,781
2,774
3,386
4,570
3,350
1,866
3,284
1,878
2,357
4,235
2,374
1,512
2,998
1,519
1,954
4,105
1,956
3,227
3,811
3,244
3,918
4,620
3,942
1,984
3,186
1,967
2,474
4,052
2,453
1,409
3,050
1,406
1,765
4,040
1,759
0,780
0,792
1,384
0,794
1,030
1,045
1,827
1,048
0,261
0,374
0,491
0,367
0,613
0,625
1,118
0,627
0,836
0,853
1,765
0,856
0,235
0,343
0,468
0,344
1,265
1,278
1,587
1,280
1,557
1,573
1,954
1,575
0,302
0,392
0,446
0,379
1,486
1,502
1,668
1,494
1,836
1,856
2,061
1,846
0,352
0,453
0,483
0,461
0,819
0,831
1,436
0,830
1,072
1,087
1,879
1,085
0,311
0,420
0,633
0,424
0,523
0,533
1,152
0,533
0,708
0,722
1,560
0,722
0,268
0,380
0,558
0,376
TS EN 61439-1
MK S T D
MKA 1654-STD
E L E K T R İ K
E MKLINE
3024744
3024740
3024692
3024742
3024738
3024690
100
160
225
4
5
5
4
5
5
4
5
5
3024743
3024739
3024691
6
Standard Straight Length Dimensions
BUSBAR TYPE
CONDUCTOR TYPE
PROTECTION DEGREE
COMPONENT
BUSBAR CURRENT
CONDUCTOR CONFIGURATION
STD-Standard Length Busbar / Codes
L1, L2, L3, N, PE(Housing)
L1, L2, L3, N, PE+Housing
L1, L2, L3, N, CPE, PE(Housing)
L1, L2, L3, N, PE(Housing)
L1, L2, L3, N, PE+Housing
L1, L2, L3, N, CPE, PE(Housing)
L1, L2, L3, N, PE(Housing)
L1, L2, L3, N, PE+Housing
L1, L2, L3, N, CPE, PE(Housing)
L1, L2, L3, N, PE(Housing)
L1, L2, L3, N, PE+Housing
L1, L2, L3, N, CPE, PE(Housing)
MKC 1054 Busbar
MKC 1055 Busbar
MKC 1057 Busbar
MKC 2254 Busbar
MKC 2255 Busbar
MKC 2257 Busbar
MKC 1654 Busbar
MKC 1655 Busbar
MKC 1657 Busbar
Sample Order:160A, Aluminium, IP55, 4 conductors
Standard Straight Length
CodeCurrent (A) Conductors Copper (Cu) Configuration
Standard length of busbar is 300cm.
Provision of a total of 10 plug-in points onboth sides of the busbar are providedas a standard feature.
3000
200 600 600 600 600 400
200600600600600400
50
115
NL1L2L3PE
3024402
3024401
3024400
160
225
100
4
5
5
4
5
5
4
5
5
3024741
3024737
3024689
3164718
3164719
3176276
L1, L2, L3, N, PE(Housing)
L1, L2, L3, N, PE+Housing
L1, L2, L3, N, CPE, PE(Housing)
L1, L2, L3, N, PE(Housing)
L1, L2, L3, N, PE+Housing
L1, L2, L3, N, CPE, PE(Housing)
MKA 1054 Busbar
MKA 1055 Busbar
MKA 1057 Busbar
MKA 1654 Busbar
MKA 1655 Busbar
MKA 1657 Busbar
CodeCurrent (A) Conductors Aluminium (Al) Configuration
MKA 2254 Busbar
MKA 2255 Busbar
MKA 2257 Busbar
(A) (A)mm
(A)mm
100
160
225
6
10,5
17
MK
50
115
A
NL1L2L3PE
Minimum Special StraightLength:without plug-in point500mmwith plug-in point1000mm
MKC 2255-100
E L E K T R İ K
E MKLINE
160
100
160
225
100
4
5
5
4
5
5
4
5
5
4
5
5
4
5
5
3024710
3024706
3024685
3024396
3024397
3024395
3024713
3024709
3024688
3024712
3024708
3024687
3024711
3024707
3024686
7
Special Straight LengthDimensions
BUSBAR TYPECONDUCTOR TYPE
PROTECTION DEGREE
COMPONENT
BUSBAR CURRENT
CONDUCTOR CONFIGURATION
Conductor Cross SectionsFor non-standard modules, please contact our company.
Current Aluminium Copper
X SpecialStraight Length
(cm)
Special straight length busbars aremanufactured as standard at 1m, 1,5m and 2m.
Sample Order:225A, Copper, IP55, 5 conductors, 100cm.
X-Special Straight Length Busbar / Codes
Current (A)
Current (A)
Conductors
Conductors
Aluminium (Al)
Copper (Cu)
Configuration
Configuration
L1, L2, L3, N, PE(Housing)
L1, L2, L3, N, PE+Housing
L1, L2, L3, N, CPE, PE(Housing)
L1, L2, L3, N, PE(Housing)
L1, L2, L3, N, PE+Housing
L1, L2, L3, N, CPE, PE(Housing)
L1, L2, L3, N, PE(Housing)
L1, L2, L3, N, PE+Housing
L1, L2, L3, N, CPE, PE(Housing)
L1, L2, L3, N, PE(Housing)
L1, L2, L3, N, PE+Housing
L1, L2, L3, N, CPE, PE(Housing)
L1, L2, L3, N, PE(Housing)
L1, L2, L3, N, PE+Housing
L1, L2, L3, N, CPE, PE(Housing)
L1, L2, L3, N, PE(Housing)
L1, L2, L3, N, PE+Housing
L1, L2, L3, N, CPE, PE(Housing)
MKA 1654-X Special straight length
MKA 1655-X Special straight length
MKA 1657-X Special straight length
MKA 1054-X Special straight length
MKA 1055-X Special straight length
MKA 1057-X Special straight length
MKC 1054-X Special straight length
MKC 1055-X Special straight length
MKC 1057-X Special straight length
MKC 1654-X Special straight length
MKC 1655-X Special straight length
MKC 1657-X Special straight length
MKC 2254-X Special straight length
MKC 2255-X Special straight length
MKC 2257-X Special straight length
Code
Code
Special StraightLength
10,5
17
22,5
X
50
115
NL1L2L3PE
225
4
5
5
MKA 2254-X Special straight length
MKA 2255-X Special straight length
MKA 2257-X Special straight length
3176277
3176278
3176279
MK
MKC 2254 - FD
50
115
NL1L2L3PE
E L E K T R İ K
E MKLINE
50
115
NL1L2L3PE
4
5
5
4
5
5
3024723
3024721
3024697
3024724
3024722
3024698
100 Al100 Cu
160 Al160 Cu225 Cu
8
290±10mm
320±10mm
290±10mm
320±10mm
Sample Order:225A, Copper IP55, 4 conductors
Flexible Elbow(Vertical)
Flexible Elbow(Horizontal)
FD Flexible Elbow (Al/Cu)
CodeCurrent(A) Conductors Copper (Cu)
MKC 1054-FD Flexible Elbow
MKC 1055-FD Flexible Elbow
MKC 1057-FD Flexible Elbow
MKC 2254-FD Flexible Elbow
MKC 2255-FD Flexible Elbow
MKC 2257-FD Flexible Elbow
BUSBAR TYPE
CONDUCTOR TYPE
PROTECTION DEGREE
COMPONENT
BUSBAR CURRENT
CONDUCTOR CONFIGURATION
Flexible ElbowsCodes
4
5
5
3176289
3176290
3176291
MKA 2254-FD Flexible Elbow
MKA 2255-FD Flexible Elbow
MKA 2257-FD Flexible Elbow
225 Al
MK
MKC 1654 - DT
50
115
NL1L2L3PE
E L E K T R İ K
E MKLINE
4
5
5
4
5
5
100 Al100 Cu
160 Al160 Cu225 Cu
3024715
3024714
3024696
3024720
3024719
3024699
9
650±10mm
Expansion UnitCodes
Sample Order:160A, Copper, IP55, 4 conductors
DT Expansion Unit(Horizontal and vertical)
BUSBAR TYPECONDUCTOR TYPE
PROTECTION DEGREE
COMPONENT
BUSBAR CURRENT
CONDUCTOR CONFIGURATION
DT Expansion Unit (Al/Cu)
CodeCurrent(A) Conductors Copper (Cu)
MKC 1054-DT Expansion
MKC 1055-DT Expansion
MKC 1057-DT Expansion
MKC 2254-DT Expansion
MKC 2255-DT Expansion
MKC 2257-DT Expansion
4
5
5
225 Al
MKA 2254-DT Expansion
MKA 2255-DT Expansion
MKA 2257-DT Expansion
3176292
3176293
3176294
111
MK
MKC 1655 - B1
50
115
NL1L2L3PE
192
140
298
E L E K T R İ K
E MKLINE
100 Al160 Al
4
5
5
4
5
5
3024735
3024729
3024704
3024736
3024730
3024705
100 Cu160 Cu225 Cu
10
Feeder BoxesCodes
B1 Feeder Box 1 (Al)
BUSBAR TYPE
CONDUCTOR TYPE
PROTECTION DEGREE
COMPONENT
BUSBAR CURRENT
CONDUCTOR CONFIGURATION
25M32
M40 32
38M50
Al
Al
Al
Cable Gland Plates
MaterialCurrent(A)
CableGlandType
InnerDiameter(mm)
*Gland plates are manufactured as per M40gland unless it is specified during order.
100
*160
225
B1 Feeder Box 1
CodeCurrent(A) Aluminium (Al)
B1 Feeder Box 1 (Cu)
CodeCurrent(A) Conductors Copper (Cu)
MKC 2254-B1 Feeder Box 1
MKC 2255-B1 Feeder Box 1
MKC 2257-B1 Feeder Box 1
MKA 1654-B1 Feeder Box 1
MKA 1655-B1 Feeder Box 1
MKA 1657-B1 Feeder Box 1
Sample Order:160A, Copper IP55, 5 conductors
225 Al
4
5
5
MKA 2254-B1 Feeder Box 1
MKA 2255-B1 Feeder Box 1
MKA 2257-B1 Feeder Box 1
3176280
3176281
3176282
MK
MKA 1654 - B2
111
140
298
192
50
115
NL1L2L3PE
E L E K T R İ K
E MKLINE
4
5
5
3024733
3024727
3024702
4
5
5
3024734
3024728
3024703
100 Al160 Al
100 Cu160 Cu225 Cu
11
Feeder BoxesCodes
BUSBAR TYPE
CONDUCTOR TYPE
PROTECTION DEGREE
COMPONENT
BUSBAR CURRENT
CONDUCTOR CONFIGURATION
Al100 25M32
M40Al 32
Al225 38M50
Sample Order:160A, Aluminium IP55, 4 conductor
B2 Feeder Box 2
*160
Cable Gland Plates
MaterialCurrent(A)
CableGlandType
InnerDiameter(mm)
*Gland plates are manufactured as per M40gland unless it is specified during order.
B2 Feeder Box 2 (Al) B2 Feeder Box 2 (Cu)
MKA 1654-B2 Feeder Box 2
MKA 1655-B2 Feeder Box 2
MKA 1657-B2 Feeder Box 2
CodeCurrent(A) Conductors Aluminium (Al)
MKC 2254-B2 Feeder Box 2
MKC 2255-B2 Feeder Box 2
MKC 2257-B2 Feeder Box 2
CodeCurrent(A) Conductors Copper (Cu)
4
5
5
MKA 2254-B2 Feeder Box 2
MKA 2255-B2 Feeder Box 2
MKA 2257-B2 Feeder Box 2
3176283
3176284
3176285
225 Al
MK
160 160
MKA 1654-BO
405
170
675
355
E L E K T R İ K
E MKLINE
50
115
NL1L2L3PE
3024731
3024725
3024700
4
5
5
4
5
5
3024732
3024726
3024701
100 Al160 Al
100 Cu160 Cu225 Cu
12
Al100
*160
25M32
M40Al 32
Al225 38M50
BUSBAR TYPE
CONDUCTOR TYPE
PROTECTION DEGREE
COMPONENT
BUSBAR CURRENT
CONDUCTOR CONFIGURATION
Sample Order:160A, Aluminium, IP55, 4 conductors
Feeder BoxesCodes
BO-Central Feeder Box
Cable Gland Plates
MaterialCurrent(A)
CableGlandType
InnerDiameter(mm)
*Gland plates are manufactured as per M40gland unless it is specified during order.
BO-Central Feeder Box (Cu)BO-Central Feeder Box (Al)
MKA 1654-BO Central F.B.
MKA 1655-BO Central F.B.
MKA 1657-BO Central F.B.
MKC 2254-BO Central F.B.
MKC 2255-BO Central F.B.
MKC 2257-BO Central F.B.
CodeCurrent(A) Conductors Copper (Cu)CodeCurrent(A) Conductors Aluminium (Al)
3176286
3176287
3176288
MKA 2254-BO Central F.B.
MKA 2255-BO Central F.B.
MKA 2257-BO Central F.B.
4
5
5
225 Al
3024677
3024668
3024676
3024667
3024675
3024666
3024695
3024694
3024693
16
16
4
5
5
4
5
5
13
0
210
98
MK P 1 6 5
E L E K T R İ K
E MKLINE
13
BUSBAR TYPE
BOX TYPE
PROTECTIONDEGREECONDUCTORS
BOX RATING
IP55 - 5- 4- 5- 7 (Clean Earth)
DEVICE TYPEEMPTY - B
MCB - M
POLE1234
CURRENT
Tap-Off BoxesCodes (16A)
CodeCurrent(A) Conductors Configuration Device
• Maximum size of outgoing cable Ø13 mm.
Description
L1, L2, L3, N, PE(Housing)
Standard Tap-Off Boxes (MCB)
L1, L2, L3, N, PE+Housing
L1, L2, L3, N, CPE, PE(Housing)
Tap-off boxes with sockets are supplied with 16A MCB as standard. For the tap-off boxes with sockets, please contact to supplier.Warning: For balancing phase loads, please calculate and select the correct tap-off box types and quantities.
• Maximum size of outgoing cable Ø13 mm. • For non-standard tap off boxes, please contact our company.
MKP 1654-B Tap-Off Box
MKP 1655-B Tap-Off Box
MKP 1657-B Tap-Off Box
Standard Tap-Off Boxes (EMPTY)
CodeCurrent(A) Conductors Configuration DeviceDescription
16 A - 16
455
6 A10 A16 A
L1, L2, L3, N, PE(Housing)
L1, L2, L3, N, PE+Housing
L1, L2, L3, N, CPE, PE(Housing)
Suitable for
MCB/Fuse holder
1x16A with MCB
3x16A with MCB
1x16A with MCB
3x16A with MCB
1x16A with MCB
3x16A with MCB
MKP 1654-M Tap-Off Box
MKP 1654-M Tap-Off Box
MKP 1655-M Tap-Off Box
MKP 1655-M Tap-Off Box
MKP 1657-M Tap-Off Box
MKP 1657-M Tap-Off Box
16
5
335
97
,5
12
0
90
3024665
3024664
3024663
3024662
3024661
3024660
40
40
4
5
5
4
5
5
MK P 4 0 5
E L E K T R İ K
E MKLINE
14
BUSBAR TYPE
BOX TYPE
PROTECTIONDEGREECONDUCTORS
BOX RATING40 A - 40
IP55 - 5455
- 4- 5- 7 (Clean Earth)
EMPTY - B
MCB - M
POLE1234
CURRENT32 A40 A
Tap-Off BoxesCodes (40A)
• • Maximum size of outgoing cable Ø22 mm.As standard with 3x40A automatic fuse is used in boxes.
Standard Tap-Off Boxes (MCB)
Tap-off boxes with sockets are supplied with 40A MCB as standard. For the tap-off boxes with sockets, please contact to supplier.Warning: For balancing phase loads, please calculate and select the correct tap-off box types and quantities.
DEVICE TYPE
Standard Tap-Off Boxes (EMPTY)
CodeCurrent(A) Conductors Configuration DeviceDescription
MKP 4054-B Tap-Off Box
MKP 4055-B Tap-Off Box
MKP 4057-B Tap-Off Box
• Maximum size of outgoing cable Ø22 mm. • For non-standard output boxes, please contact our company.
L1, L2, L3, N, PE(Housing)
L1, L2, L3, N, PE+Housing
L1, L2, L3, N, CPE, PE(Housing)
Suitable for
MCB/Fuse holder
CodeCurrent(A) Conductors Configuration DeviceDescription
MKP 4054-M Tap-Off Box
MKP 4055-M Tap-Off Box
MKP 4057-M Tap-Off Box
L1, L2, L3, N, PE(Housing)
L1, L2, L3, N, PE+Housing
L1, L2, L3, N, CPE, PE(Housing)
3 x 40A
with MCB
3024623
3024631
3024630
63
4
5
5
16
5
335
97
,5
12
0
90
MK P 5
E L E K T R İ K
E MKLINE
15
BUSBAR TYPE
BOX TYPE
PROTECTIONDEGREECONDUCTORS
BOX RATING63 A - 63
IP55 - 5455
- 4- 5- 7 (Clean Earth)
DEVICE TYPED02 - D
POLE1234
CURRENT40 A50 A63 A
Tap-Off BoxesCodes(63A - D02)
Standard Tap-Off Boxes (D02)
• Maximum size of outgoing cable Ø22 mm. • As standard with 3x63A D02 type fuse base is used in boxes. For output boxes with plug, please contact our company.
Warning: For balancing phase loads, please calculate and select the correct tap-off box types and quantities.
CodeCurrent(A) Conductors Configuration DeviceDescription
MKP 6354-D Tap-Off Box
MKP 6355-D Tap-Off Box
MKP 6357-D Tap-Off Box
L1, L2, L3, N, PE(Housing)
L1, L2, L3, N, PE+Housing
L1, L2, L3, N, CPE, PE(Housing)
3x63 A
D02 Type
Fuse Base
16
5
335
97
,5
12
0
90
MK P 5
3024718
3024717
3024716
80
4
5
5
3024659
3024658
3024657
80
4
5
5
E L E K T R İ K
E MKLINE
16
BUSBAR TYPE
BOX TYPE
PROTECTIONDEGREECONDUCTORS
BOX RATING80 A - 80
IP55 - 5455
- 4- 5- 7 (Clean Earth)
DEVICE TYPEEMPTY - BMCB - M
POLE1234
CURRENT40 A50 A63 A80 A
Tap-Off BoxesCodes (80A)
Standard Tap-Off Boxes (EMPTY)
Standard Tap-Off Boxes (MCB)
• • Maximum size of outgoing cable Ø22 mm.As standard with 3x80A MCB.
Tap-off boxes with sockets are supplied with 80A MCB as standard. For the tap-off boxes with sockets, please contact to supplier.Warning: For balancing phase loads, please calculate and select the correct tap-off box types and quantities.
CodeCurrent(A) Conductors Configuration DeviceDescription
MKP 8054-B Tap-Off Box
MKP 8055-B Tap-Off Box
MKP 8057-B Tap-Off Box
L1, L2, L3, N, PE(Housing)
L1, L2, L3, N, PE+Housing
L1, L2, L3, N, CPE, PE(Housing)
Suitable for
MCB/Fuse holder
CodeCurrent(A) Conductors Configuration DeviceDescription
3 x 80A
with MCB
MKP 8054-M Tap-Off Box
MKP 8055-M Tap-Off Box
MKP 8057-M Tap-Off Box
L1, L2, L3, N, PE(Housing)
L1, L2, L3, N, PE+Housing
L1, L2, L3, N, CPE, PE(Housing)
Standard Tap-Off Boxes (EMPTY)
3046458
3043818
3063567
80
4
5
5
Suitable for
MCB
MKP 8054-DATA-B1 Tap-off Box
MKP 8055-DATA-B1 Tap-off Box
MKP 8057-DATA-B1 Tap-off Box
L1, L2, L3, N, PE(Housing)
L1, L2, L3, N, PE+Housing
L1, L2, L3, N, CPE, PE(Housing)
Tap off Boxes (MKP-DATA)(80A) E L E K T R İ K
E MKLINE
Tap off Box Type
CURRENT RATINGS
PROTECTION DEGREE
MCB TYPE
GLANDTYPE
CONDUCTOR SIZE
MKP DATA08 B1 P3 2 D055
IP 55 5
4 Conductors5 Conductors5 Conductors (CE)
457
BM1M2M3M4M5
P1P2P3P4P5P6
1234
D0D1D2D3D4
Emptywith 1x16A MCBwith 3x16A MCBwith 1x32A MCBwith 3x32A MCBwith 3x63A MCB
Schuko(1x16A)CEE Single phase(3x16A)CEE Single phase(3x32A)CEE Three phase(5x16A)CEE Three phase(5x32A)CEE Three phase(5x63A)
1 pc2 pcs3 pcs4 pcs
DPK0DPK1DPK2DPK3DPK4
08 80 A
17
CodeCurrent(A) Conductors Configuration DeviceDescription
• Maximum size of outgoing cable Ø22 mm. • For non-standard output boxes, please contact our company.
For the tap-off boxes with sockets and MCB, please contact to supplier.Note: For balancing phase loads, please calculate and select the correct tap-off box types and quantities.
with DIN rail inside(available for 4pcs 3P MCB)May be equipped with CEE or Schuko Sockets with different configurations.( Optional )All tap off boxes with equipment fitted are manufactured with C Type ABB MCB.
Up to 80A MCBRAL 7038 Painted Aluminium HousingStandard tap-off is empty, gland plates are DPK0.
Features;
Mat.
Al
Al
M16
-----
10xM16
M25
4xM25
Al
Al
Al
DPK1
DPK0
10
---
DPK2
DPK3
DPK4
10
18
18
Cable Gland Plates
CableGland Type
OrderCode
InnerDiameter
(mm)
NUMBER OF SOCKETS
SOCKET TYPE
400332
238
16
5
34 34
11
11
47
36
43
50
5
400332
129
115
16
5
34 34
5x63ACEE
BRA9-2
BRA10
BRA11-05
BRA11-10
BRA11-15
BRA11-20
5000033
1004313
5000039
5000038
5000035
5000036
2052178
E L E K T R İ K
E MKLINEFixing Elements
Floor Installation
Fixing Elements
Roof Installation
MK-UT
Universal
Fixing
Element
Steel
Dowel (M8)
Extension Unit
Threaded Rod
Steel Dowel (M8)
Extension Unit (M8)
Threaded Rod (M8x500)
Threaded Rod (M8x1000)
Threaded Rod (M8x1500)
Threaded Rod (M8x2000)
Description
Description
Code
Code
MK-UT Universal Fixing Element
Wall Installation
Steel
Dowel (M8)
Extension Unit
Threaded Rod
18
3025370
E L E K T R İ K
E MKLINE
1004188
Vertical Shaft Installation
Fixing Elements
Fixing Elements
Code
MK "C" Type Universal Fixing Element
Description
MK
"C" Type
Universal
Fixing
Element
Steel
Dowel (M8)
Extension Unit
Threaded Rod
Wall Installation
Floor Installation
Roof Installation
Code
MK Vertical Fixing Element
Description
19
E L E K T R İ K
E MKLINE
1 2
2a
3
3a
4
4a
5
Busbar Joint Installation
Tighten the bolts of rear cover. (3a) Tighten the main bolt until the first nut is broken. (4a)
Remove the protective plastic cover.(These covers are for transportation purpose and requirednumber of covers should be used as END CLOSER unit.)
Alligne two busbars like the picture-2a and insert the busbarconductors into the block joint.
20
E L E K T R İ K
E MKLINE
1
3
2
CLICK
4
5
7
CLICK
6
•Empty tap-off boxes are produced with MCB connection cables.
When the tap-off boxes are used as single phase, the • switch will be connected to one of the phase cables.
Remaining phase cables should be insulated by using • cable terminals for your safety. In order to balance phases of busbar, connected loads to the tap off boxes should be calculated carefully.
Take cover box with lock for safety.
Tap-Off Box Installation Instructions (40-63-80A)
Attach the cable, which has a cross section suitable to theswitch current, before you install the box to the busbar.
When closing the cover of the box; insert the safety-tongue into the seat by finger touch.
When the tap-off box cover is at open position; locate thebox contacts to the busbar plug area by aligning them.
Lock the cover lock by pressing it towards the arrow direction.
Be sure that the retaining springs are attached to the busbar.
21
E MKLINE
1- Remove the cover screws. 2- Open the cover.
3- Connect a cable, which has suitable cross section,to the switch, before you install the box to the busbar.
4- Tighten the removed cover screws.
6- Be sure that, the box is fixed to the busbar properly.5- Fix the box contacts to the busbar plug area by aligning them.
E L E K T R İ K
1
3
5
2
4
3a
65a
5b
5c
7•Empty tap-off boxes are produced with MCB connection cables.
When the tap-off boxes are used as single phase, the • switch will be connected to one of the phase cables. Remaining phase cables should be insulated by using cable terminals for your safety.
In order to balance phases of busbar, connected loads to • the tap off boxes should be calculated carefully.
CLICK
Tap-Off Box Installation Instructions (16A)
22
E MKLINE
E L E K T R İ K
E-Line MK Busbar Energy Distribution System
Declarat�on
CE DECLARATION OF CONFORMITY
Product Group
Manufacturer EAE Elektrik Asansor End. Insaat San. ve Tic. A.S.
Akcaburgaz Mahallesi, 3114. Sokak,No:10 34522 Esenyurt-Istanbul
The objects of the declaration described below is in conformity with the relevant Union harmonisation
legislation. This declaration of conformity is issued under the sole responsibility of the manufacturer.
Date
20.04.2016
Standard :
EN 61439-6 Low-voltage switchgear and controlgear assemblies - Part 6: Busbar trunking systems
IEC 61439-6 Low-voltage switchgear and controlgear assemblies - Part 6: Busbar trunking systems (busways)
CE - Directive
2014/35/EU “The Low Voltage Directive”
2014/30/EU “Electromagnetic Compatibility (EMC) Directive”
2011/65/EU “Restriction of the use of certain hazardous substances (RoHS)”
Technical Document Preparation Official:
EAE Elektrik Asansor End. Insaat San. ve Tic. A.S.Akcaburgaz Mahallesi, 3114. Sokak, No:10 34522 Esenyurt-Istanbul
Emre GÜRLEYEN
Document Authorized Signatory
Elif Gamze KAYA OKDeputy General Manager
23
E L E K T R İ K
E L E K T R İ K
E MKLINE
(100...225A MK)
PRODUCT OVERVIEW
Product Overview
The busbar system shall have Al or Cu conductors for 100A, 160A and 225A.
The busbar system shall conform to the following phase configuration.
a- 4 conductors
b- 5 conductors
c- 5 conductors (with clean earth)
The insulation voltage of the busbar shall be 690V.
The busbar housing shall be of 0,50mm thick epoxy painted galvanized sheet metal. (RAL 7038)
The Al conductors shall be plated with nickel and then with tin, the Cu conductors
shall be plated only with tin. The plating shall be continuous along the conductor.
The busbar joint shall have a single bolt construction and
the nut of main joint bolt shall be a double headed nut, tightened at 20Nm.
The busbar housing shall be continuously clamped together by roll forming method.
10 plug-in windows shall be located on a standard 3m length.
Busbar and tap off boxes shall be IP55 protection class under normal operation conditions.
IP protection covers of plug-in points shall be hinged and lockable from single point.
Tap off boxes up to 16A shall be removed from the busbar before opening their lids.
The tap off boxes above 16A, shall have the following mechanical and electrical safety features.
a- The box shall only be plugged in and removed from the busbar at “OFF” position.
b- The energy on the connected load shall be automatically cut, when the box lid is open.
c- The tap off box shall comply IP2X requirements, while it is plugged into the busbar and the lid is open.
All tap off box contacts shall be silver plated.
Jawed tap off box contacts shall be reinforced by steel springs.
Busbar systems shall be tested and certified according to IEC 61439-6 by international laboratories.
Busbar system shall have flexible elbows and expansion units.
Manufacturing facility of busbar systems shall have ISO 9001 and ISO 14001 certification.
1-
2-
3-
4-
5-
6-
7-
8-
9-
10-
11-
12-
13-
14-
15-
16-
17-
L1 / L2 / L3 / N / PE(Housing)
L1 / L2 / L3 / N / PE+Housing
L1 / L2 / L3 / N / CPE / PE(Housing)
24
E L E K T R İ K
E MKLINECertificate
25
E L E K T R İ K
E MKLINE
26
Quantit
yC
om
po
nen
t
Co
mp
on
en
t Lis
t
Item
Project Design Form
Ple
ase
du
plic
ate
th
is p
ag
e fo
r yo
ur
ow
n u
se.
Nam
e
:
Date
:
Sig
natu
re :
Prepared by
Co
mp
an
y
:
Pro
ject
:
Pro
ject
No
:
E L E K T R İ K
E MKLINE
27
Quantit
yC
om
po
nen
t
Co
mp
on
en
t Lis
t
Item
Project Design Form
Ple
ase
du
plic
ate
th
is p
ag
e fo
r yo
ur
ow
n u
se.
Nam
e
:
Date
:
Sig
natu
re :
Prepared by
Co
mp
an
y
:
Pro
ject
:
Pro
ject
No
:
E L E K T R İ K
E MKLINE
28
Quantit
yC
om
po
nen
t
Co
mp
on
en
t Lis
t
Item
Project Design Form
Ple
ase
du
plic
ate
th
is p
ag
e fo
r yo
ur
ow
n u
se.
Nam
e
:
Date
:
Sig
natu
re :
Prepared by
Co
mp
an
y
:
Pro
ject
:
Pro
ject
No
:
GERMANYAUSTRIA
AZERBAIJANBAHRAIN
BANGLADESH
BELARUS
BELGIUM
BRASIL
BULGARIA
U.KINGDOM
U. A. EMIRATES
ALGERIA CHINA
CZECH REP.
DENMARK
EQ. GUINEA
ESTONIA
ETHIOPIA
MOROCCO
FRANCE
FINLAND
GHANA
SOUTH KOREA
SOUTH AFRICA
CROATIA
INDIA
NETHERLANDS IRAQIRELAND SPAIN
SWITZERLANDITALY
ICELAND
CAMEROONQATAR
KAZAKHSTAN
KENYA
CYPRUS
KONGOKUWAIT
LATVIALIBYA
LITHUANIA
LEBANON
LUXEMBOURGHUNGARY
MADAGASKAR
MACEDONIAMALTA
EGYPTMAURITIUS
MYANMAR
NIGERIA
NORWAY
PAKISTANPERU
POLAND
ROMANIA
RUSSIA
RWANDASLOVENIA
SERBIA
SINGAPORE
SRI LANKA
SAUDI ARABIA
SUDAN
SYRIA
CHILE
TANZANIA
THAILAND
TAIWAN
TUNISIA
TURKMENISTAN
UKRAINE
OMANVIETNAM
YEMEN
GREECEAZERBAIJAN
OMAN
TURKEY
PAKISTAN
BELGIUMNETHERLANDSPOLAND
NETHERLANDS
BELGIUM
NORWAYSWITZERLANDVIETNAM
NIGERIA
KENYA
OMAN
YEMENOMAN
ETHIOPIA
TURKMENISTANTURKMENISTAN
SERBIASINGAPORE
U. A. EMIRATES
SUDAN
TANZANIA
CHILE
VIETNAMTURKMENISTAN
MADAGASKARSPAIN
U. A. EMIRATES
CAMEROONTHAILAND
CHILE
TURKMENISTAN
KUWAITSYRIA
ETHIOPIA
MADAGASKARTANZANIA
FRANCE
CAMEROON
SYRIA
U. A. EMIRATES
KENYA
LUXEMBOURG
FRANCE
UZBEKISTAN
PERUCHILESUDANOMANIRAQ
MADAGASKARLATVIA
QATAR
THAILAND
TURKEY
TURKEY
TURKEYTURKEY
TURKMENISTANMACEDONIA
IRELANDVIETNAMGHANA
CZECH REP.
BELGIUMU. A. EMIRATESSINGAPOREAZERBAIJAN
GREECE
SPAIN
U.KINGDOMCROATIA
NIGERIAQATAR
AUSTRIA
YEMEN SWITZERLANDSUDAN
RUSSIA
SOUTH KOREA
SYRIA
CAMEROON
GHANA
MYANMAR
NIGERIA
PERU
EGYPT VIETNAM
YEMEN
POLAND
VIETNAM
BULGARIA
TANZANIADENMARK
GREECE
VIETNAM
PAKISTANDENMARK
TAIWAN
MACEDONIA
AZERBAIJANSWITZERLAND
QATAR
SRI LANKANIGERIA
TURKEYPERU
SYRIAUZBEKISTAN
BULGARIA
NETHERLANDS
U. A. EMIRATES
GHANA
YEMENKAZAKHSTAN
GREECE
ESTONIAQATAR
BELGIUMAZERBAIJAN
SWITZERLAND
GHANA MADAGASKAR
MACEDONIA
SUDAN
YEMENDENMARKMADAGASKARROMANIA
RUSSIA CHINA
MYANMAR
SOUTH KOREAYEMEN
KAZAKHSTAN QATARVIETNAM
VIETNAM
UZBEKISTAN FINLANDSLOVENIA
KOREA
KAZAKHSTAN CAMEROONSLOVENIA
GREECE
ALGERIA
PRODUCT TYPES
BUSBAR ENERGY DISTRIBUTION SYSTEMS
CABLE TRAYS
TROLLEY BUSBAR ENERGY DISTRIBUTION SYSTEMS
INDOOR SOLUTIONS
SUPPORT SYSTEMS
Please visit our website for the updated version of our catalogues.www.eae.com.tr/EN
www.eae.com.tr/EN
E-LINEMK
IEC 61439-6 T Es
EAE Elektrik A.Ş.Akcaburgaz Mahallesi,
3114. Sokak, No:10 34522Esenyurt-Istanbul-TURKEY
Tel: +90 (212) 866 20 00Fax: +90 (212) 886 24 20
Busbar Systems 100-160-225 A
Catalogue 05-Eng. / Rev 10 1.000 pcs. 31/07/2019A.C.E.
EAE has full right to make any revisions or changes on this catalogue without any prior notice.
Please visit our website for the updated version of our catalogues.www.eae.com.tr/EN
9001140011800127001
ISO Mİ / AR NE AL GM EE MT
S Eİ NS T M Sİ YT SE TN EÖ MY S