Dr.ZX Operation Manual
Hitachi Construction Machinery Co. Ltd.
© 2004 Hitachi Construction Machinery Co., Ltd. All rights reserved
EPVC_LargeDiagnostic / Monitoring / Adjusting tools for following excavators.
Hitachi EX-1 (550), EX-3 (400 to 600), EX-5 (400 to 800), ZAXIS (450 to 850) Fiat Hitachi FH450-3, EX455, EX456
EPVC_MidDiagnostic / Monitoring / Adjusting tools for following excavators.
Hitachi EX-1 (USE series), EX-2 (60 to 300), EX-3 (60 to 310) EX-5 (60 to 370), ZAXIS (70 to 380) Fiat Hitachi FH-2 series, FH-3 series, EX series (less than 40 tons)
EPVC_MiniDiagnostic / Monitoring / Adjusting tools for following excavators.
Hitachi EX33Mu & EX58Mu
HMS_LargeMidMonitoring data download / Data logger setting following excavators.
Hitachi ZAXIS (70 to 850) John Deere C series (80C to 800C)
MIC_MiningMonitoring data download / Data logger setting / Monitoring / Diagnostic following excavators.
Hitachi EX1200-5/5C, EX1900-5, EX2500-1/5, EX3500-1/2/3, EX3600-5, EX5500-5
EPVC_LARGE Operation Manual
Hitachi Construction Machinery Co. Ltd.
NOTE This manual is based on Hitachi ZX series. Screen / Function /Procedure are vary by model.
1. Necessary Tools & Cable Connection2. MODEOPERATION MODE
3. Operation Mode – How to Start Dr.ZX with Operation Mode4. Operation Mode – Self-Diagnostic5. Operation Mode – Monitoring6. Operation Mode – Special Function (WU Deactivation)7. Operation Mode – Special Function (ECO Deactivation)8. Operation Mode – Special Function (Pump Adjustment)
SERVICE MODE 9. Service Mode – How to Start Dr.ZX with Service Mode10. Service Mode – Learning Data Display11. Service Mode – Monitor Panel LCD Control12. Service Mode – Parameter Change13. Service Mode – Act/Deact of Parameters
STAND ALONE MODE 14. Stand Alone Mode - How to Start Dr.ZX with Stand Alone Mode15. Stand Alone Mode – Change Password16. Stand Alone Mode – View Manuals17. Stand Alone Mode – Play Recorded Data
1. Necessary Tools & Cable Connection
Cable connection
(a) Palm OS PDA (b) Serial cable (c) Dr.ZX communication cable
Dr.ZX must be installed. Hitachi recommends following models. SONY Clie PEG-TJ25 PalmOne Inc.
m125 / 130 / 500 / 505 / 515 Tungsten T2 / T3 / C
For SONY Clie PEG-TJ25 Purchase from CPD. P/no. is4629330 (Hitachi uniqueparts).
For PalmOne PDAs Purchase from local market.
HotSync serial
This is Hitachi unique part. Make anorder to your parts ordering channel.Hitachi part no. is 4476512.
Dr.Z Palm OS PDA Palm
Serial cable
Dr.ZX cable
Equipment
Connect toDr.ZX connector.
Necessary tools
Product name is
X cable Serial cable
2. Mode
Start Dr.ZX with Operation Mode
Self-Diagnostic Monitoring / Recording Sensor out-put signal WU (Warming-up function) Deactivation ECO (Economy function) Deactivation Pump (Angle sensor) Adjustment
Start Dr.ZX with Service Mode.
Check Engine Learning Data Monitor Engine Speed & Hydraulic Oil TemperatureChange Parameter(s), such as follows
Engine RPM Auto-Lub. Interval Pump Max. Displacement Pump Max. Torque Pump Cut-off Pressure
Activate or Deactivate Changed Parameters
Change Password Replay Recorded Monitoring Data Refer Instant Operation Manual
EPVC_Large
NOTE For non-current models (suchas EX-2/-3/-5), operation &stand-alone mode will apply
Stand-alone Mode (No need to hock up with equipment)
3. Operation Mode – How to Start Dr.ZX with Operation Mode (1/4)
Turn key switch “OFF”.
Check enginelearning switch isOFF.
Connect Dr.ZX to equipment.
Turn key switch “ON”.
Start Dr.ZX. Select “EPVC_Large”.
Start operation mode.
Special Function
Monitoring View / Recording
Self - Diagnostic Operation mode menu.
Switch on Palm.
3. Operation Mode – How to Start Dr.ZX with Operation Mode (2/4)
(b) Check Engine learning switch is OFF
OFF
Stamp
(a) Turn key switch “OFF”
Fuse box
(c) Connect Dr.ZX to equipment.
3. Operation Mode – How to Start Dr.ZX with Operation Mode (3/4)
(d) Turn key switch “ON”
Main switch is vary by Palm model.Above shows Palm m500 / 505 / 515.
(f) Start Dr.ZX (e) Switch “ON” Palm
Tap “Dr.ZX” icon on Palm.
Check model. If model is correct, tap“correct”, if not tap “ESC” and contactto your dealer.
Tap “START”. Tap “ ” of EPVC_Large.
(h) Start operation mode (i) Model / Version information (g) Select “EPVC_Large”.
3. Operation Mode – How to Start Dr.ZX with Operation Mode (4/4)
(j) Operation mode main menu
4. Operation Mode – Self-Diagnostic (1/3)
Select “Self-diagnostic”.
No error detected.
Message will display.
Start Dr.ZX with Operation mode.
Error(s) are detected.
Tap “Details” for check detail of each error code.
Error code(s) will display.
Tap “ESC”. Carry out “Retry”.
Still error(s) are detected
No errordetected.
Message will display.
Error code(s) will display.
4. Operation Mode – Self-Diagnostic (2/3)
If Dr.ZX could not detect any error(s),above message will display. Tap“ESC”.
Tap “Retry B” for retrying. Error code(s) that detected willdisplay to Palm. Tap “ESC” for retry.
If Dr.ZX could not detect any error(s),above message will display. Tap“ESC”.
Tap “ ” of Self-Diagnostic.
(a) Start self-diagnostic
(d) Retry (c) Error(s) detected (e) No error detected
(b) No error detected
4. Operation Mode – Self-Diagnostic (3/3)
Tap “ESC” fir quit self-diagnostic. Message will show meanings of eachcode, and corrective action. Tap“Next” for view additional informationor other code.
If Dr.ZX still detect any error(s) , errorcode(s) will display. Tap “Details” forcheck error(s).
(f) Still error(s) detected (g) Explanation of each code
NOTE
(h) Explanation of each code
Refer service manuals fortroubleshooting.
5. Operation Mode – Monitoring (1/5)
Select Monitor display.
Enter model code & serial no.
Select item. (Max. four items)
Start monitoring.
Write recorded data to data bank.
Start recording. If data bank isn’tempty, Dr.ZX will ask overwrite.
Enter comment if you want.
Select data bankthat store recorded data.
Operation mode menu.
NOTE If you did not enter model code & equipmentserial no., you can’t record monitoring data toPalm.
5. Operation Mode – Monitoring (2/5)
(a) Start Monitoring
Tap “ ” of Monitor Display
(b) Enter model code & s/no.
Tap columns and enter model code &serial no. If you did not enter modelcode & serial no., you can’t recordmonitoring data.
TIP You can use keyboard to entermodel code & serial no. by tap“abc” or “123” on GRAFFITI area.
Selected item
Number of selected item(s).
Clear selected item(s).
Item changeover button
(c) Tap “OK”
After enter model & serial no., tap“OK”. If you don’t need to recordmonitoring data, no need to entermodel code & serial no. Just tap “OK”.
Tap “ ” of item you want monitor. Youcan monitor four items in once.
(d) Select monitoring item(s)
5. Operation Mode – Monitoring (3/5)
(h) Recording
(e) Start display data
After selecting item(s), tap “Start” fordisplay monitoring data.
Item(s) will display. Screen will varyby selected items. Tap “Hold” forpause data. If you want quit, tap“ESC”.
(g) Start Recording
Tap “Record” for record monitoringdata. Dr.ZX will record data for three(3) seconds.
During recording, above screen willdisplay.
NOTE If you did not entermodel code & serial no.,“Record” button shallnot appear.
(f) Start display monitoring data
5. Operation Mode – Monitoring (4/5)
(k) Data bank is empty
If selected data bank is empty, abovescreen will display. Tap “Write” forstore recorded monitoring data.
(l) Confirmation
After data stored, confirmation screenwill display. Tap “ESC” to quit, or ifyou want enter comment, tap“Comment”.
(l) Enter comment
Tap comment column, and comment. After entering, tap “OK
(i) Select data bank
Tap data bank (figure) that you wantto store recorded data.
If selected data bank alreadydata, above screen will appear“OverWrite” for store recorded tap “ESC” for back to previous m
(j) Data bank is not empty
has. Tapdata,enu.
enter”.
TIP You can use keyboard to entercomment. Tap “abc” on GRAFFITIare.
NOTE Click here for how to repalyrecorded data.
5. Operation Mode – Monitoring (5/5)
Items can be monitored (vary by model)
6. Operation Mode – Special Function (WU Deactivation –1/2)
Select Special Function.
Select WU Deactivation
WU has deactivated.
Execute Special functionmenu
WU Function. WU stands for Warming-Up. This function is, when start engine while hydraulic oil
temperature is less than elsius, computer will increase low idle rpm for warmhydraulic oil quickly.
zero (0) C
6. Operation Mode – Special Function (WU Deactivation –2/2)
(a) Select special function
Tap “ ” of Special Function.
(b) Select WU deactivation
Tap “ ” of WU Deactivation.. Tap “Execute for Deactivation. If youwant back to previous menu, tap“ESC”.
(d) Confirmation
After deactivation, above messagewill display. Tap ”ESC” for quit.
NOTE WU (Warming-up function) wilre-activate when key switch isturned “OFF”.
(c) Select WU deactivation
l
7. Operation Mode – Special Function (ECO Deactivation –1/2)
Select Special Function.
Select ECO Deactivation
ECO has deactivated.
Execute Special functionmenu
ECO Function ECO stands for ECOnomy. This function is, when all levers are in neutral position,
computer will reduce eng 1600min-1 gradually. If any lever(s) are operated, enginerpm will back.
ine rpm to
7. Operation Mode – Special Function (ECO Deactivation –2/2)
(a) Select special function
Tap “ ” of Special Function.
(b) Select ECO deactivation
Tap “ ” of ECO Deactivation.. Tap “Execute for Deactivation. If youwant back to previous menu, tap“ESC”.
(d) Confirmation
After deactivation, above messagewill display. Tap ”ESC” for quit.
NOTE ECO (Economy function) wilre-activate when key switch isturned “OFF”.
(c) Select WU deactivation
l
8. Operation Mode – Special Function (Pump Adjustment –1/9)
Turn key switch“OFF”.
Check engine learning switch is OFF.
Connect Dr.ZX to equipment.
Start engine. Switch on Palm. Start Dr.ZX. Confirm engine is running with low idle.
Start operationmode.
Operation mode menu.
Switch OFF Palm.
Remove both angle sensorsfrom pump.
Start “EPVC_Large”.
Confirm sensors are connecting to harness.
Continue to next page.
8. Operation Mode – Special Function (Pump Adjustment –2/9)
Select “Max. Disp. Holding”.
Tighten bolts & washers.
Adjust sensor shaft.
Wait more than five (5) seconds.
Adjust angle sensors.
Install angle sensors to pump.
Select “Special Function”.
Apply a film ofgrease.
From previous
8. Operation Mode – Special Function (Pump Adjustment –3/9)
(a) Switch off Palm (b) Turn key switch off
Main switch is vary by Palm model.Above shows Palm m500 / 505 / 515.
Pump-2 sensor
Pump-1 sensor
Pump-2 sensor
Loose Bolts
(c) Remove A (angle) sensors from pump
Remove two (2) angle sensors frompump. When removing, take care notto lose internal spacer & fastenerspring.
Engine
Pump-1 sensor
ZX450 & ZX500 ZX600 & ZX800
8. Operation Mode – Special Function (Pump Adjustment –4/9)
Confirm sensors are connecting toharness.
(d) Confirm connection
OFF
Fuse box(e) Check Engine learning switch is OFF
Connect toharness
Stamp
(f) Confirm Dr.ZX is connecting to equipment.
8. Operation Mode – Special Function (Pump Adjustment –5/9)
(g) Start engine (h) Run engine at low idle
Confirm engine control dial positionlowest engine speed.
Main switch is vary by Palm model.Above shows Palm m500 / 505 / 515.
(i) Switch on Palm
Tap “ ” of EPVC_Large. Tap “Dr.ZX” icon on Palm.
(j) Start Dr.ZX (k) Select “EPVC_Large”. (l) Start operation mode
Tap “START”.
8. Operation Mode – Special Function (Pump Adjustment –6/9)
Check model. If model is correct, tap“correct”, if not tap “ESC” and contactto Hitachi.
(m) Model / Version information
Tap “ ” of Special Function.
(n) Select special function
Tap “ ” of pump adjustment.
(o) Select pump adjustment
Tap “ ” of pump adjustment.
(p) Select Max. Disp. Holding
n signals (voltage) from anglers will display.
(q) Sensor signal displayed
NOTE After tap “Max. Holding”, wait morefive (5) seconds. Comwill operate main pumaximum displacposition.
Retursenso
Disp. thanputer
mp toement
8. Operation Mode – Special Function (Pump Adjustment –7/9)
With the punch mark on the angel sensor shaft, towards theopposites side of the harness, and adjust (turn) shaft thatsignal voltage is as following specification.
ZX450 & ZX500 Pump-1 angle sensor; 1.60V Pump-2 angle sensor; 3.40V
ZX600 & ZX800 Pump-1 angle sensor: 1.60V Pump-2 angle sensor; 1.60V
A Sensor
Punch Mark
Main pump
Feedback Shaft
(s) Apply grease
Apply a film of grease to the surface of fastenerspring, and install It into the cavity on the feedbackshaft.
FastenerSpring
(r) Adjust sensor shaft
8. Operation Mode – Special Function (Pump Adjustment –8/9)
Install sensors to main pump. Set signal voltage as following specifications,by adjusting the holes of A (angle) sensor.
ZX450 & ZX500 Pump-1 angle sensor; 1.60V +0.02/-0.02 Pump-2 angle sensor; 3.40V +0.02/-0.02
ZX600 & 800
Pump-1 angle sensor; 1.60V +0.02/-0.02 Pump-2 angle sensor; 1.60V +0.02/-0.02
(s) Adjust sensors
Pump-2 sensor
Pump-1 sensor
Harness Side
ZX450 & ZX500 Angle Sensors Location
Harness Side
Pump-2 sensor
Pump-1 sensor
Harness Side
Engine
ZX450 & ZX500 Angle Sensors Location
Harness Side
8. Operation Mode – Special Function (Pump Adjustment –9/9)
Tap “ESC” for quit pump adjustment.
(u) Quit pump adjustment
Tighten bolts &washers.
(t) Tighten bolts
Tighten bolts & washers to 9.8Nm (1.0kgf-m, 7.2 lbf-ft).
9. Service Mode – How to Start Dr.ZX with Service Mode (1/4)
Turn key switch “OFF”.
Switch on the engine-learning switch.
Connect Dr.ZX to equipment.
Turn key switch“ON”.
Switch on Palm. Start Dr.ZX. Select “EPVC_Large”.
Start service mode.
Wait more thanten(10) seconds.
Confirm currentDr.ZX mode.
Confirm model.
Check Engine Learning Data
Monitor Panel LCD (Liquid Crystal Display) Control
Change Parameter.
Service mode menu.
Select Specialfunction.
Activate or Deactivate Changed Parameters
9. Service Mode – How to Start Dr.ZX with Service Mode (2/4)
(b) Switch on Engine-learning switch
ON
Fuse box
NOTE Wait more than ten (10)seconds, after keyswitch is turned off.
Stamp
(a) Turn key switch “OFF”
(c) Connect Dr.ZX to equipment.
9. Service Mode – How to Start Dr.ZX with Service Mode (3/4)
(d) Turn key switch “ON”
Main switch is vary by Palm model.Above shows Palm m500 / 505 / 515.
(f) Start Dr.ZX (e) Switch “ON” Palm
Tap “Dr.ZX” icon on Palm. NOTE Shall not start engine.
(g) Select “EPVC_Large”
Tap “ ” of EPVC_Large. Check model. If model is correct, tap“correct”, if not tap “ESC” and contactto Hitachi.
Tap “START”.
(i) Model / Version information (h) Start service mode
9. Service Mode – How to Start Dr.ZX with Service Mode (4/4)
Tap “Rechecked”.
(j) Service mode confirmation (k) Select “Special Function” (l) Service mode menu
Tap “ ” of “Special Function”.
10. Service Mode – Learning Data Display (1/2)
Data shows EC motor position when engine stop or engine running on maximum speed.
Service mode menu.
Select “Learning Data Display”.
Select “Engine Stop Position”.
Position will display.
Select “Engine Stop Position”.
Position will display/.
10. Service Mode – Learning Data Display (2/2)
(a) Select “Learning Data Display”.
Tap “ ” of “Learning Data Display” inservice mode menu.
(b) Select item
Tap “ ” of item you want to view.
(c) Engine max. speed position
EC Motor position will display. Tap“ESC” for quit.
EC Motor position will display. Tap“ESC” for quit.
(c) Engine stop position
11. Service Mode – Monitor Panel LCD Control (1/2)
This function is able or disable to display actual engine speed and/or hydraulic oil temperature on monitor panel LCD( Liquid Crystal Display).
Display SelectSwitch
This switch will changeover
LCD (Liquid Crystal Display)
Monitor Panel
Service menu.
Select “Monitor Display”.
Select “Engine Actual Speed”.
Select “display”or “not to
Select “Execute”.
mode
display”.
Select “Hydraulic Oil Temp.”.
Select “display”or “not to display”.
Select “Execute”.
11. Service Mode – Monitor Panel LCD Control (2/2)
(a) Select “Monitor Display”.
Tap “ ” of “Monitor Display” inservice mode menu.
(b) Select item
Tap “ ” of item you want to view onmonitor panel.
Tap “Disp” for allow to displayinformation, and tap “NoDisp” for notallow to display information.
(c) Select control
(c) Execute
If execution is completed, abovemessage will display. Tap “ESC” forquit.
(c) Quit
Tap “Execute” for activate control.
12. Service Mode – Parameter Change (1/4)
Please click here for view items can be changed parameters.
Service mode menu.
Select “Parameter Change”.
Select item. Enter parameter.
Confirmation screen.
Tap “Execute”. End message. Tap “ESC”.
Select “Execute”.
NOTE You have to carry out “Act/Deact of Parameters”function after changing parameters. Otherwisechanged parameter(s) shall not transfer toequipment main computer.
12. Service Mode – Parameter Change (2/4)
(a) Select “Parameter Change”
Tap “ ” of “Parameter Change” inservice mode menu.
Tap “ ” of item you want to view.
(c) Enter figures
Tap entering column, and enterfigures to be adjusted.
TIP You can use keyboard to enterfigures. Tap “123” on GRAFFITIare.
Tap “ ” or “ ” tochangeover items.
(c) Tap “Execution”
(b) Select item
12. Service Mode – Parameter Change (3/4)
(c) Confirmation screen
Confirmation screen will display. Iffigures are correct, tap “Execute”.
Tap “ESC” to quit.
(c) Quit
12. Service Mode – Parameter Change (4/4)
Items can be changed parameters (vary by model)
13. Service Mode – Act/Deact of Parameters (1/2)
Service mode menu.
Tap “Act”. Changed parameter(s) will reflect to computer.
Will deact changed parameter(s) in computer
Tap “Deact”.
Select “Act/Deact of Parameters“.
13. Service Mode – Act/Deact of Parameters (2/2)
(a) Select “Parameter Change”
Tap “ ” of “Parameter Change” inservice mode menu.
(b) Select “Act” or “Deact”.
Select activation ordeactivation.
Tap “Execute”, and tap “ESC” to quit.
(c-1) Activation
Tap “Execute”, and tap “ESC” to quit.
(c-1) Deactivation
14. Stand Alone Mode - How to Start Dr.ZX with Stand Alone Mode (1/2)
Play recordedmonitoring data.
View manuals.
Main screen. Change passwordStart “EPVC_Large”.
Start Dr.ZX. Switch on Palm.
14. Stand Alone Mode - How to Start Dr.ZX with Stand Alone Mode (2/2)
Tap “Dr.ZX” icon on Palm.
(b) Start Dr.ZX
Main switch is vary by Palm model.Above shows Palm m500 / 505 / 515.
(a) Switch “ON” Palm
NOTE No need to hook upwith equipment.
(c) Select “EPVC_Large”
Tap “ ” of EPVC_Large.
(d) Main screen
15. Stand Alone Mode – Change Password (1/3)
Main screen. Tap “Password”. Enter current password.
New password will apply.
Re-enter new password.
NOTE New password will apply toall Dr.ZX function.
Enter new password.
15. Stand Alone Mode – Change Password (2/3)
Tap “Password”.
(a) Main screen
Enter current password. Defaultpassword is zx2000.
(b) Enter current password
TIP You can use keyboard to enterpassword. Tap “abc” on GRAFFITIare.
(c) Tap “Execute” (d) Enter new password (e) Tap “Execute”
15. Stand Alone Mode – Change Password (3/3)
(f) Re-enter new password (g) Tap “Execute” (h) Tap “ESC”
Password has been changed.
16. Stand Alone Mode – View Manuals (1/2)
View service mode manual.
View operationmode manual.
View engine learning mode manual.
Select Manual. Tap “Op Manual”.Main screen.
16. Stand Alone Mode – View Manuals (2/2)
Tap “ ” of mode that you want toview manual.
(a) Main screen
Tap ”Op. Manual”.
(b) Select Manual
(c) Operation mode manual
Tap “ESC” to quit.
(d) Service mode manual (e) Engine learning mode manual
17. Stand Alone Mode – Play Recorded Data (1/2)
Tap “Record Disp”.
Play recorded data.
Select data bank.Main screen.
NOTE To play recoded data, you have to record monitoringdata before.
17. Stand Alone Mode – Play Recorded Data (2/2)
Tap number of data bank that youwant to play, and tap “Play Back”.
(a) Main screen
Tap ”Record Disp”.
(b) Select data bank
Recorded monitoring data will display.Tap “ESC” to quit.
(c) Recoded data
EPVC_MID Operation Manual
Hitachi Construction Machinery Co. Ltd.
NOTE This manual is based on Hitachi ZX series. Screen / Function /Procedure are vary by model.
1. Necessary Tools & Cable Connection2. MODEOPERATION MODE
3. Operation Mode – How to Start Dr.ZX with Operation Mode4. Operation Mode – Self-Diagnostic5. Operation Mode – Monitoring6. Operation Mode – Special Function (WU Deactivation)7. Operation Mode – Special Function (ECO Deactivation)
SERVICE MODE 8. Service Mode – How to Start Dr.ZX with Service Mode9. Service Mode – Learning Data Display10. Service Mode – Monitor Panel LCD Control11. Service Mode – Parameter Change
STAND ALONE MODE 12. Stand Alone Mode - How to Start Dr.ZX with Stand Alone Mode13. Stand Alone Mode – Change Password14. Stand Alone Mode – View Manuals15. Stand Alone Mode – Play Recorded Data
1. Necessary Tools & Cable Connection
Cable connection
(a) Palm OS PDA (b) Serial cable (c) Dr.ZX communication cable
Dr.ZX must be installed. Hitachi recommends following models. SONY Clie PEG-TJ25 PalmOne Inc.
m125 / 130 / 500 / 505 / 515 Tungsten T2 / T3 / C
For SONY Clie PEG-TJ25 Purchase from CPD. P/no. is4629330 (Hitachi uniqueparts).
For PalmOne PDAs Purchase from local market.
HotSync serial
This is Hitachi unique part. Make anorder to your parts ordering channel.Hitachi part no. is 4476512.
Dr.Z Palm OS PDA Palm
Serial cable
Dr.ZX cable
Equipment
Connect toDr.ZX connector.
Necessary tools
Product name is
X cable Serial cable
2. MODE
Start Dr.ZX with Operation Mode
Self-Diagnostic Monitoring / Recording Sensor out-put signal WU (Warming-up function) Deactivation ECO (Economy function) Deactivation
Start Dr.ZX with Service Mode.
Check Engine Learning Data Monitor Engine Speed & Hydraulic Oil TemperatureChange Parameter(s), such as follows
Engine RPM Auto-Lub. Interval Pump Max. Displacement Pump Max. Torque Pump Cut-off Pressure
Change Password Replay Recorded Monitoring Data Refer Instant Operation Manual
Dr.ZX
NOTE For non-current models (suchas EX-2/-3/-5), operation &stand-alone mode will apply
Stand-alone Mode (No need to hock up with equipment)
3. Operation Mode – How to Start Dr.ZX with Operation Mode (1/5)
Turn key switch “OFF”.
Check enginelearning switch isOFF.
Connect Dr.ZX to equipment.
Turn key switch “ON”.
Start Dr.ZX. Select “EPVC_Mid”.
Start operation mode.
Special Function
Monitoring View / Recording
Self - Diagnostic Operation mode menu.
Switch on Palm.
3. Operation Mode – How to Start Dr.ZX with Operation (2/5)
(b) Check Engine learning switch is OFF (a) Turn key switch “OFF”
Stamp
Hitachi ZAXIS110 & up
Hitachi ZAXIS70, 80, 75US,75UR, 135US, 225US
3. Operation Mode – How to Start Dr.ZX with Operation (3/5)
Hitachi ZAXIS70, 80, 75US,75UR, 135US, 225US
Hitachi ZAXIS110 & up
(c) Connect Dr.ZX to equipment.
3. Operation Mode – How to Start Dr.ZX with Operation Mode (4/5)
(d) Turn key switch “ON”
Main switch is vary by Palm model.Above shows Palm m500 / 505 / 515.
(f) Start Dr.ZX (e) Switch “ON” Palm
Tap “Dr.ZX” icon on Palm.
(g) Select “EPVC_Mid”
Tap “ ” of EPVC_Mid. Check model. If model is correct, tap“correct”, if not tap “ESC” and contactto your dealer.
(i) Model / Version information (h) Start operation mode
Tap “START”.
3. Operation Mode – How to Start Dr.ZX with Operation Mode (5/5)
(j) Operation mode main menu
4. Operation Mode – Self-Diagnostic (1/3)
Select “Self-diagnostic”.
No error detected.
Message will display.
Start Dr.ZX with Operation mode.
Error(s) are detected.
Tap “Details” for check detail of each error code.
Error code(s) will display.
Tap “ESC”. Carry out “Retry”.
Still error(s) are detected
No errordetected.
Message will display.
Error code(s) will display.
4. Operation Mode – Self-Diagnostic (2/3)
(b) No error detected
If Dr.ZX could not detect any error(s),above message will display. Tap“ESC”.
(a) Start self-diagnostic
Tap “ ” of Self-Diagnostic.
If Dr.ZX could not detect any error(s),above message will display. Tap“ESC”.
Tap “Retry B” for retrying.
(e) No error detected (c) Error(s) detected (d) Retry
Error code(s) that detected willdisplay to Palm. Tap “ESC” for retry.
4. Operation Mode – Self-Diagnostic (3/3)
(f) Still error(s) detected
If Dr.ZX still detect any error(s) , errorcode(s) will display. Tap “Details” forcheck error(s).
(g) Explanation of each code
Message will show meanings of eachcode, and corrective action. Tap“Next” for view additional informationor other code.
(h) Explanation of each code
Tap “ESC” fir quit self-diagnostic.
NOTE
Refer service manuals fortroubleshooting.
5. Operation Mode – Monitoring (1/5)
Select Monitordisplay.
Enter model code & serial no.
Select item. (Max. four items)
Start monitoring.
Write recorded data to data bank.
Start recording. If data bank isn’tempty, Dr.ZX will ask overwrite.
Enter comment if you want.
Select data bankthat storerecorded data.
Operation mode menu.
NOTE If you did not enter model code & equipmentserial no., you can’t record monitoring data toPalm.
5. Operation Mode – Monitoring (2/5)
Tap columns and enter model code &serial no. If you did not enter modelcode & serial no., you can’t recordmonitoring data.
(b) Enter model code & s/no. (a) Start Monitoring
Tap “ ” of Monitor Display
TIP You can use keyboard to entermodel code & serial no. by tap“abc” or “123” on GRAFFITI area.
Selected item
Number of selected item(s).
Clear selected item(s).
Item changeover button
After enter model & serial no., tap“OK”. If you don’t need to recordmonitoring data, no need to entermodel code & serial no. Just tap “OK”.
Tap “ ” of item you want monitor. Youcan monitor four items in once.
(d) Select monitoring item(s) (c) Tap “OK”
5. Operation Mode – Monitoring (3/5)
After selecting item(s), tap “Start” fordisplay monitoring data.
(e) Start display data
Item(s) will display. Screen will varyby selected items. Tap “Hold” forpause data. If you want quit, tap“ESC”.
(f) Start display monitoring data
(h) Recording (g) Start Recording
Tap “Record” for record monitoringdata. Dr.ZX will record data for three(3) seconds.
During recording, above screen willdisplay.
NOTE If you did not entermodel code & serial no.,“Record” button shallnot appear.
5. Operation Mode – Monitoring (4/5)
(k) Data bank is empty
If selected data bank is empty, abovescreen will display. Tap “Write” forstore recorded monitoring data.
(l) Confirmation
After data stored, confirmation screenwill display. Tap “ESC” for quit, or ifyou want enter comment, tap“Comment”.
(l) Enter comment
(i) Select data bank
Tap data bank (figure) that you wantto store recorded data.
If selected data bank alreadydata, above screen will appear“OverWrite” for store recorded tap “ESC” for back to previous m
(j) Data bank is not empty
Tap comment column, and comment. After entering, tap “OK
has. Tapdata,enu.
TIP You can use keyboard to entercomment. Tap “abc” on GRAFFITIare.
enter”. NOTE
Click here for how to replayrecorded data.
5. Operation Mode – Monitoring (5/5)
Items can be monitored (vary by model)
6. Operation Mode – Special Function (WU Deactivation –1/2)
Select Special Function.
Select WU Deactivation
WU has deactivated.
Execute Special functionmenu
WU Function. WU stands for Warming-Up. This function is, when start engine while hydraulic oil
temperature is less than elsius, computer will increase low idle rpm for warmhydraulic oil quickly.
zero (0) C
6. Operation Mode – Special Function (WU Deactivation –2/2)
(a) Select special function (b) Select WU deactivation
Tap “Execute for Deactivation. If youwant back to previous menu, tap“ESC”.
(c) Select WU deactivation
Tap “ ” of WU Deactivation.. Tap “ ” of Special Function.
After deactivation, above messagewill display. Tap ”ESC” for quit.
(d) Confirmation
NOTE WU (Warming-up function) wilre-activate when key switch isturned “OFF”.
l
7. Operation Mode – Special Function (ECO Deactivation –1/2)
Select Special Function.
Select ECO Deactivation
ECO has deactivated.
Execute Special functionmenu
ECO Function ECO stands for ECOnomy. This function is, when all levers are in neutral position,
computer will reduce eng 1600min-1 gradually. If any lever(s) are operated, enginerpm will back.
ine rpm to
7. Operation Mode – Special Function (ECO Deactivation –2/2)
(a) Select special function (b) Select ECO deactivation (c) Select WU deactivation
Tap “ ” of ECO Deactivation.. Tap “ ” of Special Function. Tap “Execute for Deactivation. If youwant back to previous menu, tap“ESC”.
After deactivation, above messagewill display. Tap ”ESC” for quit.
(d) Confirmation
NOTE ECO (Economy function) wilre-activate when key switch isturned “OFF”.
l
8. Service Mode – How to Start Dr.ZX with Service Mode (1/5)
Turn key switch “OFF”.
Switch on the engine-learning switch.
Connect Dr.ZX to equipment.
Turn key switch “ON”.
Switch on Palm. Start Dr.ZX. Select “EPVC_Mid”.
Start service mode.
Wait more thanten(10) seconds.
Confirm currentDr.ZX mode.
Confirm model.
Check Engine Learning Data
Monitor Panel LCD (Liquid Crystal Display) Control
Change Parameter.
Service mode menu.
Select Specialfunction.
Activate or Deactivate Changed Parameters
8. Service Mode – H
(a) Turn key switch “OFF”
NOTE Wait more than ten (10)seconds, after keyswitch is turned off.
ow to Start Dr.ZX with Service Mode (2/5)
ZX110 & up, 120C & up
(b) Switch on the Engine-learning switch
Stamp
ZX70/80/75US/75UR & 80C
8. Service Mode – How to Start Dr.ZX with Service Mode (3/5)
Hitachi ZAXIS70, 80, 75US,75UR, 135US, 225US
Hitachi ZAXIS110 & up
(c) Connect Dr.ZX to equipment.
8. Service Mode – How to Start Dr.ZX with Service Mode (4/5)
(d) Turn key switch “ON”
Main switch is vary by Palm model.Above shows Palm m500 / 505 / 515.
(f) Start Dr.ZX (e) Switch “ON” Palm
Tap “Dr.ZX” icon on Palm. NOTE Shall not start engine.
(g) Select “EPVC_Large”
Tap “ ” of EPVC_Mid. Check model. If model is correct, tap“correct”, if not tap “ESC” and contactto Hitachi.
(i) Model / Version information (h) Start service mode
Tap “START”.
8. Service Mode – How to Start Dr.ZX with Service Mode (5/5)
Tap “Rechecked”.
(j) Service mode confirmation (k) Select “Special Function” (l) Service mode menu
Tap “ ” of “Special Function”.
9. Service Mode – Learning Data Display (1/2)
Data shows EC motor position when engine stop or engine running on maximum speed.
Service mode menu.
Select “Learning Data Display”.
Select “Engine Stop Position”.
Position will display.
Select “Engine Stop Position”.
Position will display/.
9. Service Mode – Learning Data Display (2/2)
(a) Select “Learning Data Display”.
Tap “ ” of “Learning Data Display” inservice mode menu.
(b) Select item
Tap “ ” of item you want to view.
(c) Engine max. speed position
EC Motor position will display. Tap“ESC” for quit.
NOTE “Boom Angle Sensor CorrectionValue” & “Arm Angle SensorCorrection Value” are used forequipment which has lifting loadmonitor (option item).
EC Motor position will display. Tap“ESC” for quit.
(c) Engine stop position
10. Service Mode – Monitor Panel LCD Control (1/2)
This function is able or disable to display actual engine speed and/or hydraulic oil temperature on monitor panel LCD( Liquid Crystal Display).
Display SelectSwitch
This switch will changeover
LCD (Liquid Crystal Display)
Monitor Panel
Service menu.
Select “Monitor Display”.
Select “Engine Actual Speed”.
Select “display”or “not to
Select “Execute”.
mode
display”.
Select “Hydraulic Oil Temp.”.
Select “display”or “not to display”.
Select “Execute”.
10. Service Mode – Monitor Panel LCD Control (2/2)
(a) Select “Monitor Display”.
Tap “service
Tap “ ” of item you want to view onmonitor panel.
(b) Select item NOTE “Over Load Alarm” only apply toequipment which has lifting loadmonitor (option). “Hyd. Oil Filter LED” only applies toequipment which has highspecification full-flow filter (option)
Tap “Dinformaallow to
” of “Monitor Display” in mode menu.
(c) Select control (c) Execute
isp” for allow to displaytion, and tap “NoDisp” for not display information.
If execution is completed, abovemessage will display. Tap “ESC” forquit.
(c) Quit
Tap “Execute” for activate control.
11. Service Mode – Parameter Change (1/4)
Please click here for view items can be changed parameters.
Service mode menu.
Select “Parameter Change”.
Select item. Enter parameter.
Confirmation screen.
Tap “Execute”. End message. Tap “ESC”.
Select “Execute”.
11. Service Mode – Parameter Change (2/4)
(a) Select “Parameter Change”
Tap “ ” of “Parameter Change” inservice mode menu.
Tap “ ” of item you want to view.
Tap “ ” or “ ” tochangeover items.
(b) Select item
(c) Enter figures (d) Tap “Execution”
Tap entering column, and enterfigures to be adjusted.
TIP You can use keyboard to enterfigures. Tap “123” on GRAFFITIare.
11. Service Mode – Parameter Change (3/4)
(e) Confirmation screen
Confirmation screen will display. Iffigures are correct, tap “Execute”.
Tap “ESC” for quit.
(f) Quit
NOTE Changed parameter will reflect tocomputer immediately after quit.
11. Service Mode – Parameter Change (4/4)
Items can be changed parameters (vary by model)
12. Stand Alone Mode - How to Start Dr.ZX with Stand Alone Mode (1/2)
Play recordedmonitoring data.
View manuals.
Main screen. Change passwordStart “EPVC_Large”.
Start Dr.ZX. Switch on Palm.
12. Stand Alone Mode - How to Start Dr.ZX with Stand Alone Mode (2/2)
Tap “Dr.ZX” icon on Palm.
(b) Start Dr.ZX
Main switch is vary by Palm model.Above shows Palm m500 / 505 / 515.
(a) Switch “ON” Palm
No need to hook upwith equipment.
NOTE
(c) Select “EPVC_Mid”
” of EPVC_Large.Tap “
(d) Main screen
13. Stand Alone Mode – Change Password (1/3)
Main screen. Tap “Password”. Enter current password.
New password will apply.
Re-enter new password.
New password will apply toall Dr.ZX function.
NOTE
Enter new password.
13. Stand Alone Mode – Change Password (2/3)
Tap “Password”.
(a) Main screen
Enter current password. Defaultpassword is zx2000.
(b) Enter current password
TIP You can use keyboard to enterpassword. Tap “abc” on GRAFFITIare.
(c) Tap “Execute” (d) Enter new password (e) Tap “Execute”
13. Stand Alone Mode – Change Password (3/3)
(f) Re-enter new passwrod (g) Tap “Execute” (h) Tap “ESC”
Password has been changed.
14. Stand Alone Mode – View Manuals (1/2)
View service mode manual.
View operationmode manual.
View engine learning mode manual.
Select Manual. Tap “Op Manual”.Main screen.
14. Stand Alone Mode – View Manuals (2/2)
Tap “ ” of mode that you want toview manual.
(a) Main screen
Tap ”Op. Manual”.
(b) Select Manual
(c) Operation mode manual
Tap “ESC” to quit.
(d) Service mode manual (e) Engine learning mode manual
15. Stand Alone Mode – Play Recorded Data (1/2)
Tap “Record Disp”.
Play recorded data.
Select data bank.Main screen.
To play recoded data, you have to record monitoringdata before.
NOTE
15. Stand Alone Mode – Play Recorded Data (2/2)
Tap number of data bank that youwant to play, and tap “Play Back”.
(a) Main screen
Tap ”Record Disp”.
(b) Select data bank
Recorded monitoring data will display.Tap “ESC” to quit.
(c) Recoded data
EPVC_Mini Operation Manual
Hitachi Construction Machinery Co. Ltd.
This manual is based on Hitachi ZX series. Screen / Function /Procedure are vary by model.
NOTE
1. Necessary Tools & Cable Connection2. Function3. How to Start EPVC_Mini4. Displaying & Deleting Fault Code History5. Troubleshooting6. Fault Codes List7. Zone check8. Monitoring9. Current Correction
1. Necessary Tools & Cable Connection
Cable connection
(a) Palm OS PDA (b) Serial cable (c) Dr.ZX communication cable
Dr.ZX must be installed. Hitachi recommends following models. SONY Clie PEG-TJ25 PalmOne Inc.
m125 / 130 / 500 / 505 / 515 Tungsten T2 / T3 / C
For SONY Clie PEG-TJ25 Purchase from CPD. P/no. is4629330 (Hitachi uniqueparts).
For PalmOne PDAs Purchase from local market.
HotSync serial
This is Hitachi unique part. Make anorder to your parts ordering channel.Hitachi part no. is 4476512.
Dr.Z Palm OS PDA Palm
Serial cable
Dr.ZX cable
Equipment
Connect toDr.ZX connector.
Necessary tools
Product name is
X cable Serial cable
2. Function
Fault Code Disp & Del This function will show or delete fault code & operation history that memorized in
controller. Controller can keep 59 records. If more than 59 fault code and/or operationoccurred, controller would overwrite latest information to oldest record. Computer will
Troubleshooting This function will display fault code that controller is sensing. If any trouble is
occurring, PDA will shoe fault code. If PDA could not detect any fault, PDA will display “00” on each items.
E
Use this function when you feel boom stop position it too close or far. (b) Boom stop position (adjusting range is +/- 20 degree)
Use this function when you feel deceleration speed is too slow. (a) Boom & swing deceleration currency (adjusting range is +/- 100 mA)
This function allows to correct following items Current Correction
This function allows monitoring item. You can check four items in once. Monitor Display
ZONE Check This function will display current boom & swing position.
PVC_Mini
3. How to Start EPVC_Mini -1/3
Turn key switch “OFF”.
Connect Dr.ZX toequipment.
Turn key switch “ON”.
Switch on PDA
Kind menu will display. Select “EPVC_Mini”.
Main menu willdisplay. Select“Mu” type.
Main menu will display.
Software version will display. Select “Start”.
Equipment information will display. Select “OK”.
Start Dr.ZX.
3. How to Start EPVC_Mini -2/3
Tap “ ” of “EPVC_Mini”. Tap “Dr.ZX” icon. Above shows PalmOne m500. Switchlocation is vary by model.
(c) Turn key switch “ON” (a) Turn key switch “OFF” (b) Connect cable to equipment
(d) Switch on PDA (e) Start Dr.ZX (f) Kind menu
Remove small oval-shape plastic caplocate on right side of cab. Pullconnector from hole, and connectPDA.
3. How to Start EPVC_Mini -3/3
Equipment information will display.Tap “OK” to continue. Tap “ModelMenu” to back to software versiondisplay screen.
Software version will display. Tap“Start” to continue. Tap “Exit” to backto main menu.
Tap “ ” of “Mu Type”. TapMenu” to back to kind menu.
(g) Main menu
Item menu will displ
(i) Equipment information (h) Software version
(j) Item menu
“Kind
ay.
4. Displaying & Deleting Fault Code History -1/3
No fault code aredetected.
Message will display.
Fault (s) are detected.
Will Back to item menu.
Tap “Exit”
Tap “Info”. Content of fault will display.
.Select “Fault Code Disp & Del”in item menu.
Fault code(s) willdisplay.
All Fault history will delete.
Tap “Delete”
4. Displaying & Deleting Fault Code History -2/3
Tap “ ” of “Fault Code Disp & Del”. If there aren’t any fault recorded incontroller, above message willdisplay. Tap “Exit” to
Meaning of each code will display.Tap ““ ” or “ ” to check other code.Tap “Exit” to back to fault code list.
Tap “Info.” Fault codes will display (max. 59faults). Tap ““ ” or “ ” tochangeover screen.
(a) Item menu (b) No faults detected
(c) Faults detected (e) Check meaning of code (f) Meanings
4. Displaying & Deleting Fault Code History -3/3
Tap “Delete”. This will clear all faultcode history recording in controller.
Tap “Yes” to delete code. Tap “NO” toback to code list.
When clearing is finished, endmessage will display. Tap “OK” toback to item menu.
(c) End message (g) Delete codes (h) Confirmation screen
5. Troubleshooting
Tap “ ” of “Troubleshooting” in itemmenu.
If any faults are occurring, fault codewill display. If no faults are occurring,code will display as “00”. Tap “HOLD”to check content of fault.
Tap “Info.” to show meaning of eachcode. Tap “Exit” to back to item menu.
Meaning will display. Tap “Exit” toback to list of fault code.
(c) Check meaning of fault code (a) Item menu (b)List of fault codes
(d) Meaning of fault code
6. Fault Codes List
List of Codes Code Description Code
10 Abnormal CPU condition code register 75 Excessive swing sensor output signal (5V side) 11 Abnormal CPU General Register 80 Abnormal boom angle sensor (0V side) 12 Abnormal CPU mode diagnosis 81 Abnormal swing angle sensor (0V side) 18 Abnormal Interruption test 84 Abnormal boom angle sensor (5V side) 19 Abnormal 16 bit timer (CH1) 85 Abnormal swing angle sensor (5V side) 1A Abnormal 16 bit timer (CH2) A0 Abnormal 12V power voltage (Less than 10V) 1B Abnormal 16 bit timer (CH3) A1 Abnormal 12V power voltage (More than 16V) 1C Abnormal 8 bit timer F0 Initial setting has been done properly 1D Abnormal internal watch dog F1 Deactivate auto boom stop 20 Abnormal RAM read / write F2 Activate auto boom stop 40 Abnormal boom-up solenoid F3 Boom entered to critical zone with deactivating auto boom stop 41 Abnormal swing-right solenoid F4 Boom entered to critical zone with activating auto boom stop 43 Abnormal pilot shut-off relay F5 Boom moved out from critical zone 50 Abnormal boon sensor (0V side) F6 Boom moved doper in the critical zone. 51 Abnormal swing sensor (0V side) 54 Abnormal boon sensor (5V side) 55 Abnormal swing sensor (5V side) 60 Faulty boom sensor initial set value (Lower limit) 62 Faulty swing sensor initial set value (Lower limit) 64 Faulty boom sensor initial set value (Upper limit) 66 Faulty swing sensor initial set value (Upper limit) 70 Excessive boom sensor output signal (0V side) 71 Excessive swing sensor output signal (0V side) 74 Excessive boom sensor output signal (5V side)
7. Zone check -1/3
Tap “ ” of “Zone Check”.
(a) Item menu
Current boom & swing position willdisplay. Tap “Exit” to back to itemmenu.
(a) Item menu
7. Zone check -2/3
Boom Deceleration / Stop Zone
BJL2
BJL4
BJL6
B6B5
B4
B3
B2
B1
B7
BJL1
Max. swing(Right side)
Center swingPosition
Max. swing(Left side)
Right swing
Left swing
BJL3
Max boom up Boom lower Code Description Code DescriptionBJL Zone judging line by boom angle. B5 Boom up deceleration zone B1 Boom up critical zone B6 Boom up normal zone B2 Boom up stop zone B7 Boom up deceleration zone (Height limit) B3 Boom up deceleration zone B4 Boom up deceleration zone (front of operator)
7. Zone check -3/3
Swing Deceleration / Stop Zone
Max boom up Boom lower
SJL4
S6
S2
S1
SJL5
ter swing
Max. swing(Right side)
Right swing
Left swing Code DescriptionBJL Zone judging line by bSJL Zone judging line by sS1 Right swing critical zoS2 Right swing stop zone
Cen
SJL2S4
S3
SJL3
Max. swing(Left side)
Position
Code Descriptionoom angle. S3 Right swing deceleration zone wing angle. S4 Right swing deceleration zone ne S5 Right swing normal zone S6 Right swing deceleration zone (End of right swing)
8. Monitoring Selected item Item
changeover button
Number of elected item(s). s
Clear selected item(s).
Tap “Start” to start monitoring.
Tap “ ” of “Monitoring Display”.
(a) Item menu
Tap “ ” of item you want monitor. Youcan monitor four items in once.
(b) Item menu
(c) Start monitoring
Item(s) that you selected will display(information will vary by item). Tap“Hold” to pause data, and tap “Exit” toquit monitoring.
(d) Monitoring
9. Current Correction –1/2
Tap “ ” of “Current Correction”.
(a) Item menu
Tap “ ” of item you want changecurrent.
(b) Item menu
Confirm figures you changed, and tap“OK”. If you want to correct, tap “Exit”.
(d) Confirmation screen
To send figures to computer inequipment, you have to enterpassword. Tap password area, andenter “FF”.
(e) Enter password
Tap figures you want to change, andtap “OK”. To find figures tap “ ” or “ ”.If you selected “boom stop position”unit will be degree.
(c) Changing value
TIP You can use keyboard to enterpassword. Tap “abc” on GRAFFITIarea.
9. Current Correction –2/2
After entering password, tap “OK”.
(f) Enter password
End message will display. Tap “Exit”to quit.
(g) End message
HMS_LargeMid Operation Manual
Hitachi Construc ry Co. Ltd.
NOTE This manual is based on reen / Function /Procedure are vary by mod Downloaded data will belon ot disclose data tothird parties, or to even int aren’t authorized.
tion Machine
Hitachi ZX series. Scel.
g to customer. Shall nernal personnel, if they
1. Necessary Tools & Cable Connection2. FunctionICX INITIALIZING
3. ICX Initializing – How to start Dr.ZX4. ICX Initializing – General Flow5. ICX Initializing – Set Time Difference from GMT6. ICX Initializing – Set Local Time7. ICX Initializing – Synchronize Service-meter8. ICX Initializing – Model Code & Serial No. Setting
DOWNLOADING 9. Data Downloading – How to Start Dr.ZX10. Data Downloading – Download11. Data Downloading – Check Downloaded Data
ICX DIAGNOSIS 12. ICX Self Diagnoses – Flow13. ICX Self Diagnoses – Operation
CHANGE PASSWORD 14. Change Password – Flow15. Change Password – Operation
1. Necessary Tools & Cable Connection
Cable connection
(a) Palm OS PDA (b) Serial cable (c) Dr.ZX communication cable
Dr.ZX must be installed. Hitachi recommends following models. SONY Clie PEG-TJ25 PalmOne Inc.
m125 / 130 / 500 / 505 / 515 Tungsten T2 / T3 / C
For SONY Clie PEG-TJ25 Purchase from CPD. P/no. is4629330 (Hitachi uniqueparts).
For PalmOne PDAs Purchase from local market.
HotSync serial
This is Hitachi unique part. Make anorder to your parts ordering channel.Hitachi part no. is 4476512.
Dr.Z Palm OS PDA Palm
Serial cable
Dr.ZX cable
Equipment
Connect toDr.ZX connector.
Necessary tools
Product name is
X cable Serial cable
2. Function
Data Downloading Data Download Save Data Check
HMS_LargeMid
NOTE HMS_LargeMid only apply toZX & C series excavators.
ICX Initializing Set Time Difference from GMT Set Local Time Synchronize Service-Meter Reading Set Model Code & Serial No. Clear ICX Internal Memory
Change Password
ICX Self Diagnosis
Perform this function whenfollowing cases occur. (a) Deliver new equipment to
customer. (b) Replace ICX. (c) Error on downloaded data.
Perform this function when youwant to download data fromequipment.
Perform this function whenerror(s) on downloaded data.
Perform this function when youwant to change password.
3. ICX Initializing - How to start Dr.ZX -1/5
Turn key switch “OFF”.
Confirm theengine-learning switch is OFF.
Connect Dr.ZX to equipment.
Turn key switch “ON”.
Start Dr.ZX. Select “HMS_LargeMid”.
Select “Communication Start”.
Enter password.
Select “Communication Start”.
Select “ICX Initial Setting”.
Tap “Start”.
Select “Set-ICX”.
Switch on Palm.
3. ICX Initializing - How to start Dr.ZX -2/5
(b) Check Engine learning switch is OFF (a) Turn key switch “OFF”
Stamp
Hitachi ZAXIS110 & up John Deere 120C & up
Hitachi ZAXIS70, 80, 75US,75UR, 135US, 225US John Deere 80C, 135CRTS,225CCL RTS
3. ICX Initializing - How to start Dr.ZX -3/5
Hitachi ZAXIS70, 80, 75US,75UR, 135US, 225US John Deere 80C, 135CRTS,225CCL RTS
Hitachi ZAXIS110 & up John Deere 120C & up
Connect
Connect
(c) Connect Dr.ZX to equipment.
3. ICX Initializing - How to start Dr.ZX -4/5
(d) Turn key switch “ON”
Main switch is vary by Palm model.Above shows Palm m500 / 505 / 515.
(f) Start Dr.ZX (e) Switch “ON” Palm
Tap “Dr.ZX” icon on Palm. NOTE Shall not start engine.
Tap “ ” of “Set-ICX”. Tap “ ” of “Communication Start”.
(g) Select “HMS_LargeMid” (h) Select “Communication Start” (i) Select “Set-ICX”.
Tap “ ” of “HMS_LargeMid”.
3. ICX Initializing - How to start Dr.ZX -5/5
Tap entering column, and enterpassword. Default password iszx2000.
(f) Enter password.
After enter password, tap “OK”.
(g) Tap “OK”
TIP You can use keyboard to enterpassword. by tap “abc” or “123” onGRAFFITI area.
(i) Tap “Start” (j) Select “ICX Initial Setting”
Tap “ ” of “ICX Initial Setting”. If “ICXInitial Setting “ is not in menu, tap “ ”or “ ” to changeover menus.
(j) ICX initializing menu
4. ICX Initializing – General Flow
NOTE Perform ICX initialization on following cases.
(a) When delivered new equipment to customer. (b) When replaced ICX. (c) When error(s) on downloaded data.
Synchronize service meter reading.
Set model code & serial no.
Set local time. Set time-difference from GMT.
5. ICX Initializing – Set Time Difference from GMT -1/2
(a) Select enter Time Diff. from UTC
Tap “ ” of “Enter Time Diff. fromUTC”. If item is not in menu, tap “ ”or “ ” to changeover menus.
Check current time difference. If it iscorrect tap “ESC”, if you want tocorrect, tap “Correct”. Time differencetable is on next page.
(b) Check current time difference (c) Select time difference
Tap up-arrow or down-arrow to findcorrect time difference.
If you find correct time difference, tap“OK”.
(d) Set time difference
Tap “OK”
(e) Confirmation screen
5. ICX Initializing – Set Time Difference from GMT –2/2
6. ICX Initializing – Set Local Time -1/2
Tap “ ” of “Enter Date and Time”. . Ifitem is not in menu, tap “ ” or “ ” tochangeover menus.
(a) Select Enter Date and Time
Check local time. If it is wrong, tap“Correct” for correction.
(b) Check local time
NOTE Please carry out this setting, afterset time difference from GMT.
(c) Correct local time
Tap entering column and entercurrent local time.
TIP You can use keyboard to enterpassword. by tap “abc” or “123” onGRAFFITI area.
6. ICX Initializing – Set Local Time -2/2
After entering local time, tap “OK”.
(d) Tap “OK”
If local time is correct, tap “OK” forset. If not correct, tap “NG” tore-enter.
(e) Check local time (f) Confirmation screen
Tap “OK”
7. ICX Initializing – Synchronize Service-meter
Tap “ ” of “Initial Hour MeterSetting”. . If item is not in menu, tap“ ” or “ ” to changeover menus.
(b) Select Hour Meter Setting
If figures are difference, tap “Set” forsynchronizing. ICX will set it hourmeter as external hour meter.
(c) Check current service meter (d) Confirmation screen
Tap “OK”.
8. ICX Initializing – Model Code & Serial No. Setting -1/2
Tap “ ” of “Enter Model and SerialNo.”. If item is not in menu, tap “ ” or“ ” to changeover menus.
Even if model code & Serial no. arecorrect, tap “Correct”.
(b) Select Enter Model & Serial no. (c) Tap “OK” (d) Tap “Correct”
E-1 If “HCM 56”
el codeS 123456
TIP You can use keyboard to enterpassword. by tap “abc” or “123” onGRAFFITI area.
(e) Enter model code
If model code and/or serial no. are incorrect,tap column, and enter correct model codeand/or serial no. Equipment model code &serial no. are stamp on name plate.
E-2 W g mod e toad o) in f de.Foha
NOTPIN code is
Moderial no. is
NOThen enterind “0” (zer
r example, if move to enter 01G6.1G600 L 001234 is 1G6. .
el code, you havront of model co
del code is 1G6, you8. ICX Initializing – Model Code & Serial No. Setting -2/2
After correcting, tap “OK”. When initialize ICX, you have to clearICX internal memory. Otherwise youcan’t view data in some cases.
(h) Internal memory clear (g) Confirmation screen (f) Tap “OK”
(i) Memory clearing (j
Tap “OK”
) Tap “OK”
NOTE Shall not download immediately aftermemory clear, because data is empty(Dataviewer could not recognize emptydata as downloaded data. Operateequipment at least an hour, anddownload data.
9. Data Downloading – How to Start Dr.ZX -1/5
Turn key switch “OFF”.
Confirm theengine-learning switch is OFF.
Connect Dr.ZX to equipment.
Turn key switch “ON”.
Start Dr.ZX. Select “HMS_LargeMid”.
Select “Communication Start”.
Select “Data Download”.
Download Menu
Select “Data Download”.
Switch on Palm.
9. Data Downloading – How to Start Dr.ZX -2/5
(b) Check Engine learning switch is OFF (a) Turn key switch “OFF”
Stamp
ZX110 & up, 120C & up
ZX70/80/75US/75UR & 80C
9. Data Downloading – How to Start Dr.ZX -3/5
ZX110 & up, 120C & up
Connect
Connect
ZX70/80/75US/75UR & 80C
(c) Connect Dr.ZX to equipment.
9. Data Downloading – How to Start Dr.ZX -4/5
(d) Turn key switch “ON”
Main switch is vary by Palm model.Above shows Palm m500 / 505 / 515.
(f) Start Dr.ZX (e) Switch “ON” Palm
Tap “Dr.ZX” icon on Palm. NOTE Shall not start engine.
Tap “ ” of “Data Download” Tap “ ” of “Communication Start”.
(g) Select “HMS_LargeMid” (h) Select “Communication Start” (i) Select “Set-ICX”.
Tap “ ” of “HMS_LargeMid”.
9. Data Downloading – How to Start Dr.ZX -5/5
(d) Download menu
10. Data Downloading – Download
Select “Data Download”
Flow
Select “Data Download”
Quit downloading.
Downloading.
Download will start automatically afterselecting data download. If you wantto cancel download, tap “Cancel”.
(a) Select “Data Download” (b) Downloading
Tap “ ” of “Data Download”.
Palm Operation
Download will start automatically afterselecting data download. If you wantto cancel download, tap “Cancel”.
(c) Quit download
11. Data Downloading – Check Downloaded Data
Select “Save Data Check”.
Flow
View data.
Download data have not uploaded toPC will display. Tap “OK” to quit.
(a) Select “SaveDataCheck” (b) View data
Tap “ ” of “SaveDataCheck”.
Palm Operation
12. ICX Self Diagnoses – Flow
Turn key switch “OFF”.
Confirm theengine-learning switch is OFF.
Connect Dr.ZX to equipment.
Turn key switch “ON”.
Start Dr.ZX. Select “HMS_LargeMid”.
Select “Communication Start”.
Enter password.
Select “ICX Diagnosis”.
If errors are shown, tap “Retry”.
Tap “Start”.
Select “Set-ICX”.
Switch on Palm.
13. ICX Self Diagnoses – Operation -1/5
(b) Check Engine learning switch is OFF (a) Turn key switch “OFF”
Stamp
ZX110 & up, 120C & up
ZX70/80/75US/75UR & 80C
13. ICX Self Diagnoses – Operation -2/5
ZX110 & up, 120C & up
Connect
Connect
ZX70/80/75US/75UR & 80C
(c) Connect Dr.ZX to equipment.
13. ICX Self Diagnoses – Operation -3/5
(d) Turn key switch “ON”
Main switch is vary by Palm model.Above shows Palm m500 / 505 / 515.
(f) Start Dr.ZX (e) Switch “ON” Palm
Tap “Dr.ZX” icon on Palm. NOTE Shall not start engine.
Tap “ ” of “Set-ICX”. Tap “ ” of “Communication Start”.
(g) Select “HMS_LargeMid” (h) Select “Communication Start” (i) Select “Set-ICX”.
Tap “ ” of “HMS_LargeMid”.
13. ICX Self Diagnoses – Operation -4/5
Tap entering column, and enterpassword. Default password iszx2000.
(f) Enter password.
After enter password, tap “OK”.
(g) Tap “OK”
TIP You can use keyboard to enterpassword. by tap “abc” or “123” onGRAFFITI area.
(i) Tap “Start” (j) Select “ICX Diagnosis”
Tap “ ” of “ICX Initial Setting”. If “ICXInitial Setting “ is not in menu, tap “ ”or “ ” to changeover menus.
13. ICX Self Diagnoses – Operation -5/5
If errors have not detected, abovemessage will display. Tap “ESC” toquit.
(f) No error(s) detected
Content of error will display. Tap “ ”or “ ” to changeover error.Tap ”ESC” to quit.
(g) Error(s) detected
If any errors have detected, errorcode will display. Tap “Retry” forconfirmation.
(h) Still error has detected (h) Still error has detected
If still errors have detected, errorcode will display. Tap “Detail” to checkcontent of each error.
14. Change Password – Flow
Turn key switch “OFF”.
Confirm theengine-learning switch is OFF.
Connect Dr.ZX to equipment.
Turn key switch “ON”.
Start Dr.ZX. Select “HMS_LargeMid”.
Select “Communication Start”.
Enter password.
NOTE New password will apply toall Dr.ZX function.
Change password.
Tap “Password”.
Select “Set-ICX”.
Switch on Palm.
15. Change Password – Operation -1/5
(b) Check Engine learning switch is OFF (a) Turn key switch “OFF”
Stamp
ZX110 & up, 120C & up
ZX70/80/75US/75UR & 80C
15. Change Password – Operation -2/5
ZX110 & up, 120C & up
Connect
Connect
ZX70/80/75US/75UR & 80C
(c) Connect Dr.ZX to equipment.
15. Change Password – Operation -3/5
(d) Turn key switch “ON”
Main switch is vary by Palm model.Above shows Palm m500 / 505 / 515.
(f) Start Dr.ZX (e) Switch “ON” Palm
Tap “Dr.ZX” icon on Palm. NOTE Shall not start engine.
Tap “ ” of “Set-ICX”. Tap “ ” of “Communication Start”.
(g) Select “HMS_LargeMid” (h) Select “Communication Start” (i) Select “Set-ICX”.
Tap “ ” of “HMS_LargeMid”.
15. Change Password – Operation -4/5
Tap entering column, and enterpassword. Default password iszx2000.
(f) Enter password.
After enter password, tap “OK”.
(g) Tap “OK”
TIP You can use keyboard to enterpassword. by tap “abc” or “123” onGRAFFITI area.
(b) Enter current password (i) Tap “Password”
Enter current password. Defaultpassword is zx2000.
TIP You can use keyboard to enterpassword. Tap “abc” on GRAFFITIare.
15. Change Password – Operation -5/5
(c) Tap “Execute” (d) Enter new password (e) Tap “Execute”
(f) Re-enter new password (g) Tap “Execute” (h) Tap “ESC”
NOTE New password will apply to allDr.ZX function.
MIC Mining Super Large Excavators (EX1200-5 & up) Monitoring System
Operation Manual
Hitachi Construction Machinery Co. Ltd.
1. Necessary Tools & Cable Connection2. Connector Location on Equipment for Monitoring3. How to start MIC_Mining4. Using CODE by SituationCODE
5. Code “SAD-P”6. Code “SAI-P”7. Code “DDL-P”8. Code “MEC-P”9. Code “SEC-P”10. Code “SEC-P”
1. Necessary Tools & Cable Connection
(b) HotSync® Serial cable (c) Download cable
Dr.ZX must be installed. Hitachi recommends following models. SONY CLIe PEG-TJ25 PalmOne Inc.
m125 / 130 / 500 / 505 / 515 Tungsten T2 / T3 / C
Purchase from local market. Providecable that adapt to your Palm.
This is Hitachi unique part. Make anorder to your parts ordering channel.Hitachi part no. is 4486988.
Palm
Serial cable
Download cable
Equipment
Necessary tools
2. Connector Location on Equipment for Monitoring
(a) EX1200-5 (b) EX1200-5C (c) EX1900-5 & up
3. How to start MIC_Mining – 1/3
Connect cable to equipment.
Check lamp on download cable is off.
Check jumper connector is not connecting to cable.
Turn key switch to off position.
Turn key switch to on position.
Check lamp on download cable is blinking.
Start Dr.ZX Switch on a PDA.
Start MIC_Mining.
3. How to start MIC_Mining – 2/3
(01) Turn key switch “OFF” (02) Connect cable to equipment
Connect cable to equipment. Makesure that key switch is at of position.Otherwise there is a possibility thatfuse will burn out.
(c) Turn key switch “ON”
Make sure that nothing is connectedto jumper connector on downloadcable.
(03) Check Jumper connector
Check lamp on cable is blinking at acertain interval.
(05) Check lamp is blinking
Above shows PalmOne m500. Switchlocation is vary by model.
(06) Switch on PDA
(c) Turn key switch “ON” (04) Turn key switch “ON”
3. How to start MIC_Mining – 3/3
Tap “Dr.ZX” icon.
(07) Start Dr.ZX
Tap “ ” of “EPVC_Mini”.
(08) Kind menu (09) Main screen
Tap home icon.
(10) Quit MIC_Mining
4. Using CODE by Situation SAD-P Initialize DLU When deliver equipment to customer.
SAI-P Set equipment serial no.recorded in DLU & initializing.
When replace DLU.
Download data from equipment.
When data could not view on data viewer. MEC-P
DDL-P
Clear DLU internal memory.
SEC-P
Check communication linebetween controller & DLU.
Check communication linebetween sensor & controller.
CMC-P
Troubleshooting
5. Code “SAD-P” –1/9 When perform this code Perform this code, when you deliver equipment to customer. Otherwise DLU would not record monitoring data properly, and also you or your customer could not view monitoring data by viewer. Flow of this code
Set service meter reading.
Check equipment serial no. recorded in Data logger.
Set local date & time. Set time difference from GMT.
Clear memory in data logger.
Check information recorded in data logger.
Confirmation
5. Code “SAD-P” –2/9
Tap “SettingAdjustment” in toolsmenu.
Tap menu icon. Tap “ ” to set time differencebetween GMT. List of time differenceis at Code “SAD-P” –9/9.
(01) Set time difference (02) Date & Time adjustment (03) Date & Time adjustment
Enter name of person who will setdate & time at name column, andenter clock at work code column.
(04) Date & Time adjustment
TIP You can use keyboard to enterpassword. Tap “abc” or “123” onGRAFFITI area.
Tap “Next”.
(05) Date & Time adjustment
5. Code “SAD-P” –3/9
Date & time current recorded in DLUwill display. If you have to adjust, tap“Change”, if no need to change, tap“Set”.
(06) Date & Time adjustment
Tap “Date”.
(07) Date & Time adjustment te
Tap “Today”. Date & year will setautomatically. Before setting date,confirm date on Palm is same aslocal.
(08) Date & Time adjustment
Tap “Time”.
(09) Date & Time adjustment
Tap hour and adjust to local bytapping “ ” “ ”.
(10) Date & Time adjustment
Tap minute and adjust to local bytapping “ ” “ ”.
(11) Date & Time adjustment
5. Code “SAD-P” –4/9
Tap “SettingAdjustment” in toolsmenu.
Main screen Tap menu icon.
Tap minute and adjust to local bytapping “ ” “ ”.
(12) Date & Time adjustment
If date & time are same as local, tap“Set”.
(13) Date & Time adjustment
Message will display. Tap “Ok” to setdate & time. Tap “Back” to correctdate & time.
(14) Date & Time adjustment
(15) Service meter adjustment (16) Service meter adjustment (17) Service meter adjustment
5. Code “SAD-P” –5/9
Enter name of person who will setservice meter at name column, andenter run at work code column.
(18) Service meter adjustment
TIP You can use keyboard to enterpassword. Tap “abc” or “123” onGRAFFITI area.
Tap “Next”.
(19) Service meter adjustment
If service meter reading is not matchto equipment, tap “Change”.
(20) Service meter adjustment
Tap “ ” “ ”, and adjust servicemeter reading to actual equipment.
(21) Service meter adjustment
(22) Service meter adjustment
5. Code “SAD-P” –6/9
Tap “SettingAdjustment” in toolsmenu.
Main screen Tap menu icon. Message will display. Tap “Ok” to setservice meter reading. Tap “Back” tocorrect service meter reading.
(23) Service meter adjustment (24) Serial no. check (25) Serial no. check
(26) Serial no. check
Enter name of person who will checkserial no. at name column, and enterserial-no at work code column.
(27) Serial no. check
TIP You can use keyboard to enterpassword. Tap “abc” or “123” onGRAFFITI area.
5. Code “SAD-P” –7/9
Main screen
Tap “Next”.
(28) Serial no. check
If serial no. does not match toequipment, carry out “SAI-p”. Tap“Set”.
(29) Serial no. check.
Tap “Ok”.
(30) Serial no. check
Even serial no. is correct, pleasecarry out memory clear, when delivernew equipment to customer.Otherwise data will corrupt.
(31) Serial no. check
Tap “Ok”.
(31) Serial no. check (32) Confirmation
5. Code “SAD-P” –8/9
Tap menu icon.
(33) Confirmation
Tap “SystemCheck” in tools menu.
(34) Confirmation
Confirm every information on thisscreen are correct. If not, pleasere-adjust. If serial no. doesn’t match,perform SAI-P.
(35) Confirmation
5. Code “SAD-P” –9/9
6. Code “SAI-P” –1/9
When perform this code Perform this code, when you replaced DLU. Otherwise you can’t view monitoring data on data viewer. Flow of this code
Set equipment serial no.
Clear memory in data logger.
Set local date & time. Set time difference from GMT.
Set service meter reading.
Check equipment serial no. recorded in Data logger.
Clear memory in data logger.
6. Code “SAI-P” –2/9
Tap “SettingAdjustment” in toolsmenu.
Main screen Tap menu icon.
(01) Serial no. correcting (02) Serial no. correcting (03) Serial no. correcting
Enter name of person who will setserial no. at name column, and enterserial-no at work code column.
(04) Serial no. correcting
TIP You can use keyboard to enterpassword. Tap “abc” or “123” onGRAFFITI area.
Tap “Next”.
(05) Serial no. correcting
6. Code “SAI-P” –3/9
Serial no. currently recorded in DLUwill display. Tap “Change”.
(06) Che Serial no. correcting
Tap serial no. column, and entercorrect serial no.
(07) Serial no. correcting.
TIP You can use keyboard to enterpassword. Tap “abc” or “123” onGRAFFITI area.
After entering correct serial no., tap“Set”.
(08) Serial no. correcting
If serial no. you entered is correct, tap“Ok”. If you want to re-enter serial no.,tap “Back”.
(09) Serial no. correcting
Tap “Yes” to clear DLU internalmemory. Otherwise data will corrupt.
(10) Serial no. correcting
6. Code “SAI-P” –4/9
Tap menu icon. Tap “Ok”.
(11) Serial no. correcting
Tap “ ” to set time differencebetween GMT. List of time differenceis at Code “SAI-P” –9/9.
(12) Set time difference (13) Date & Time adjustment
Tap “SettingAdjustment” in toolsmenu.
(14) Date & Time adjustment
Enter name of person who will setdata & time at name column, andenter clock at work code column.
(15) Date & Time adjustment
TIP You can use keyboard to enterpassword. Tap “abc” or “123” onGRAFFITI area.
6. Code “SAI-P” –5/9
Tap “Next”.
(16) Date & Time adjustment
Date & time current recorded in DLUwill display. If you have to adjust, tap“Change”, if no need to change, tap“Set”.
(17) Date & Time adjustment
Tap “Date”.
(18) Date & Time adjustment te
Tap “Today”. Date & year will setautomatically. Before setting date,confirm date on Palm is same aslocal.
(19) Date & Time adjustment
Tap “Time”.
(20) Date & Time adjustment
Tap hour and adjust to local bytapping “ ” “ ”.
(21) Date & Time adjustment
6. Code “SAI-P” –6/9
Tap minute and adjust to local bytapping “ ” “ ”.
(22) Date & Time adjustment
Tap minute and adjust to local bytapping “ ” “ ”.
(23) Date & Time adjustment
If date & time are same as local, tap“Set”.
(24) Date & Time adjustment
Main screen Message will display. Tap “Ok” to setdate & time. Tap “Back” to correctdate & time.
(25) Date & Time adjustment
Tap menu icon.
(26) Service meter adjustment (27) Service meter adjustment
6. Code “SAI-P” –7/9
Tap “SettingAdjustment” in toolsmenu.
(28) Service meter adjustment
Enter name of person who will setservice meter at name column, andenter run at work code column.
(29) Service meter adjustment
TIP You can use keyboard to enterpassword. Tap “abc” or “123” onGRAFFITI area.
Tap “Next”.
(30) Service meter adjustment
If service meter reading is not matchto equipment, tap “Change”.
(31) Service meter adjustment
Tap “ ” “ ”, and adjust servicemeter reading to actual equipment.
(32) Service meter adjustment
6. Code “SAI-P” –8/9
Main screen
(33) Service meter adjustment
Message will display. Tap “Ok” to setservice meter reading. Tap “Back” tocorrect service meter reading.
(34) Service meter adjustment (35) Confirmation
Tap menu icon.
(36) Confirmation
Tap “SystemCheck” in tools menu.
(37) Confirmation
Confirm every information on thisscreen are correct. If not, pleasere-adjust.
(38) Confirmation
6. Code “SAI-P” –9/9
7. Code “DDL-P” –1/5 When perform this code Perform this code, when you attempt to download monitoring data from equipment Flow of this code
Enter name of person who will attempt to donwload.
End message will display
Start download. Set time difference from GMT.
NOTE Downloaded data will belong tocustomer. Shall not disclose data tothird parties, or to even internalpersonnel, if they aren’t authorized.
7. Code “DDL-P” –2/5
Tap name column, and enter namewho attempt to download. If youalready registered, tap “ ” to findyour name.
(01) Enter name
Tap “ ” to set time differencebetween GMT. List of time differenceis at Code “DDLP” –3/5.
(02) Set time difference
TIP You can use keyboard to enterpassword. Tap “abc” or “123” onGRAFFITI area.
Tap “Next”.
(03) Download
(04) Download
Information will display. Tap “OK” toquit.
(05) Download
7. Code “DDL-P” –3/5
7. Code “DDL-P” –4/5
Caution
Do not terminate palm applicationwhile downloading. Otherwise datawill corrupt.
Caution - 01
Do not change key switch to anyposition while downloading.Otherwise data will corrupt.
Caution - 02
Do not disconnect cables whiledownloading. Otherwise data willcorrupt.
Caution - 03
7. Code “DDL-P” –5/5
Errors If any error occurred, please take following procedure, and retry download.
Disconnect download cables.
Quit tools running on Palm.
Connect cable to equipment.
Turn key switch to off position.
Check lamp on download cable is off.
Check jumper connector is not connecting to cable.
Turn key switch to on position.
Check lamp on download cable is blinking.
Retry code DDL-P. Switch on a PDA.
8. Code “MEC-P” –1/3 When perform this code Perform this code, when you can’t view data on data viewer, other information (such as equipment serial no., data & time, engine running hour) that recorded in DLU are correct. Flow of this code
Select “SettingAdjustment” in menu.
Enter name & work code “serial-no”.
Clear memory.
8. Code “MEC-P” –2/3
Main screen Tap menu icon.
(01) Memory clear (02) Memory clear
Tap “SettingAdjustment” in toolsmenu.
(03) Memory clear
Enter name of person who will clearinternal memory at name column, andenter serial-no at work code column.
(04) Memory clear
TIP You can use keyboard to enterpassword. Tap “abc” or “123” onGRAFFITI area.
Tap “Next”.
(05) Memory clear
8. Code “MEC-P” –3/3
Tap “Set”.
(06) Memory clear
Tap “Ok”.
(07) Memory clear
Tap “Yes”
(08) Memory clear
Tap “Ok”.
(09) Memory clear
9. Code “SEC-P” –1/4 When perform this code Perform this code, when you want to check communication line between sensor to controller. Flow of this code
Select “Conditions” is System check menu.
Select “Sensor Faults”in .system check menu.
Select “SystemCheck”in tools menu.
9. Code “SEC-P” –2/4
Main screen
(01) Sensor communication check
Tap menu icon.
2) Sensor communication check
Tap “SystemCheck” in tools menu.
(03) Sensor communication check
System check main screen.
(04) Sensor communication check
Tap menu icon.
(05) Sensor communication check
Select “Condition” in system checkmenu.
(06) Sensor communication check
(0
9. Code “SEC-P” –3/4
ipment conditions will display/ck figure(s) will change whilerating. Information will vary by
equipment models.
) Sensor communication check
Tap menu icon.
(08) Sensor communication check
Select “Sensor Fault” in system checkmenu.
(09) Sensor communication check
If there is a “NG” on sensor, there willbe communication fault in sensorand/or sensor line. Tap “ ” or “ ” tochangeover sensor.
(10) Sensor communication check
EquCheope
(07
9. Code “SEC-P” –4/4
Sensors equip on each models
EX1200-5/5C EX1900-5 EX2500-5 EX3600-5 EX5500-5
Hydraulic. Oil Temperature Sensor O O O O O
Fuel Temperature Sensor NA NA O NA O
Operation Pressure Sensor O O O NA O
Travel Pressure Sensor O O O O O
[R] Engine Speed Sensor O O O O O
[L] Engine Speed Sensor NA NA NA NA O
Intake Air Temperature Sensor 1 NA NA NA O NA
Intake Air Temperature Sensor 2 NA NA NA O NA
Front Swing Temperature Sensor NA NA NA O NA
Governor Angle Sensor O O NA O NA
Coolant Temperature Sensor NA NA NA O NA
Fast-fill Pressure Sensor NA NA O O O
Exhaust Temperature Sensor 1 O O NA O NA
Exhaust Temperature Sensor 2 NA O NA O NA
O = Equip on equipment NA = Not available on equipment
10. Code “CEC-P” –1/3 When perform this code Perform this code, when you want to check communication line between controller and DLU.. Flow of this code
Select “Conditions” is System check menu.
Select “SystemCheck”in tools menu.
10. Code “CEC-P” –2/3
Main screen
(01) Communication condition
Tap menu icon.
(02) Communication condition
Tap “SystemCheck” in tools menu.
(03) Communication condition
System check main screen.
(04) Communication condition
Tap menu icon.
(05) Communication condition
Select “Condition” in system checkmenu.
(06) Communication condition
10. Code “SEC-P” –3/3
Communication condition will display.If communication condition is not“OK”, please check line betweencontroller and DLU.
(07) Communication condition