Alarm Raised Stands for Means
PPI-LOS PDH Port InterfaceLoss of Signal
A configured PDH trib has a loss of signal
PPI-AIS
PDH Port InterfaceAlarm IndicationSignal
A configured PDH trib is receiving AIS
PPI-EXC
PDH Port InterfaceExcessive Errors
A configured PDH trib is receiving excessive errors
PPI-TF PDH Port InterfaceTransmit Failure
A configured PDH trib output signal has fallen bellow apredefined threshold
PPI-Unexp_Signal PDH Port InterfaceUnexpected Signal
An unconfigured PDH port is receiving a PDH signal
RS-LOS
Regenerator SectionLoss of Signal
STM-n port has loss of signal
RS_Laser_Shutdown
Regenerator SectionLaser Shutdown
As a result of an RS-LOS alarm, the STM-n port hasshut down its transmitting laser.
MS-AIS
Multiplexer SectionAlarm IndicatorSignal
STM-n port is receiving an AIS signal.
LP-PLM
Low Path PayloadMismatch
There’s a hole in the VC12 – or something other thanpayload ‘2’ is being received.
LP-UNEQ Low PathUnequipped
There’s a hole in the VC12 – or something other thanpayload ‘2’ is being received.
TU-AIS
Tributary Unit Alarm
Indication Signal
AIS detected on the VC4.
PPI-Loop back PDH Port InterfaceLoop back
Loop has been applied to the specified PDH port.
RS-Loop back
Regenerator SectionLoop back
Loop has been applied to the specified STM-n port.