DISCOVERY™ MI
Discovery is a trademark of General Electric Company.
Meaningful insights. From your patient to every patient.
TRUE DISCOVERY DISCOVERY MI LIGHTBURST DIGITAL QUANTITATION DIGITAL INDUSTRIAL SHAPING THE FUTURECLINICAL IMAGES DISCLAIMERSREVOLUTION EVOSCALABILITY
2 5 Y E A R S O F I N N O V A T I O N
Discovery LS
Discovery STDiscovery STE
Discovery VCT
Discovery 690Discovery 600
Discovery 710
Discovery 610
SIGNA PET/MR
Discovery IQ
Discovery MI/DR
Advance
TRUE DISCOVERY DISCOVERY MI LIGHTBURST DIGITAL QUANTITATION DIGITAL INDUSTRIAL SHAPING THE FUTURECLINICAL IMAGES DISCLAIMERSREVOLUTION EVOSCALABILITY
Continue your efforts to diagnose and stage disease earlier with technology that detects smaller lesions1
CLINICAL WORK THAT EXCELS BEYOND WHAT YOU THOUGHT WAS POSSIBLE
Expand your diagnostic service offerings
1Improved detectability as demonstrated in phantom testing
TRUE DISCOVERY DISCOVERY MI LIGHTBURST DIGITAL QUANTITATION DIGITAL INDUSTRIAL SHAPING THE FUTURECLINICAL IMAGES DISCLAIMERSREVOLUTION EVOSCALABILITY
I N T R O D U C I N G D I S C O V E R Y M I
Q . C L E A R
• Up to 2x improvement in quantitative accuracy (SUVmean)
• Up to 2x improvement in image quality (SNR)
• Q.CorePower+ Dual reconstruction for advanced needs
D I G I T A L M O T I O N F R E E
• Q.Static – MotionFree for all patients
• Q.Freeze – 100% counts, 100% motion correction
• Q.Flow – Patient centric workflow
L I G H T B U R S T D I G I T A L D E T E C T O R
• Up to 2x improvement in volumetric resolution1
• Highest NEMA sensitivity of any TOF PET/CT system2
• Highest NECR of any TOF PET/CT system3
R E V O L U T I O N T M E V O
• HiLight Clarity Detector – 0.28 mm resolution
• Up to 82% reduction in CT dose with ASIR-VTM 4,5
• Smart MAR – One stop shop PET/CT
3 Comparing Discovery MI to other TOF PET/CT scanners reported in ITN online comparison charts (May 2016), Up to 20 kBq/ml
4 In clinical practice, the use of ASiR-V may reduce CT patient dose depending on the clinical task, patient size, anatomical location, and clinical practice. A consultation with a radiologist and a physicist should be made to
determine the appropriate dose to obtain diagnostic image quality for the particular clinical task. Low Contrast Detectability (LCD), Image Noise, Spatial Resolution and Artifact were assessed using reference factory protocols
comparing ASiR-V and FBP. The LCD measured in 0.625 mm slices and tested for both head and body modes using the MITA CT IQ Phantom (CCT183, The Phantom Laboratory), using model observer method.
5 Image quality as defined by low contrast detectability.
TRUE DISCOVERY DISCOVERY MI LIGHTBURST DIGITAL QUANTITATION DIGITAL INDUSTRIAL SHAPING THE FUTURECLINICAL IMAGES DISCLAIMERSREVOLUTION EVOSCALABILITY
LightBurst Digital Detector
ENGINEERED FOR PRECISION
TRUE DISCOVERY DISCOVERY MI LIGHTBURST DIGITAL QUANTITATION DIGITAL INDUSTRIAL SHAPING THE FUTURECLINICAL IMAGES DISCLAIMERSREVOLUTION EVOSCALABILITY
L I G H T B U R S T D I G I T A L
E N G I N E E R E D F O R P R E C I S I O N
TRUE DISCOVERY DISCOVERY MI LIGHTBURST DIGITAL QUANTITATION DIGITAL INDUSTRIAL SHAPING THE FUTURECLINICAL IMAGES DISCLAIMERSREVOLUTION EVOSCALABILITY
Large to medium scintillator crystal array share a common light guide
Photomultiplier (QUAD-PMT) without electronics
LightBurst Digital DetectorConventional PET
L I G H T B U R S T D I G I T A L D E T E C T O R
E N G I N E E R E D F O R P R E C I S I O N
Silicon Photomultiplier (SiPM) with ASIC
Excellent timing and energy resolutions
Digital Compton scatter recovery with no resolution trade off
High thermal conductive pad
Extracts heat from detector improving stability
Small Scintillator crystal and Enhanced Spectral Reflectors
Excellent count-rate performance and system resolution
TRUE DISCOVERY DISCOVERY MI LIGHTBURST DIGITAL QUANTITATION DIGITAL INDUSTRIAL SHAPING THE FUTURECLINICAL IMAGES DISCLAIMERSREVOLUTION EVOSCALABILITY
15
.6cm
20
.0 c
m
Conventional PET
Sensitivity
7.5 cps/kBq
30 kcps @ 2.3 kBq/ml (FDG)
Coverage
15.6 cm axial FOV
7-8 bed per whole-body
Technology
Analog TOF – 1024x PMT
549 ps TOF resolution
Crystal - LBS
4.2 x 6.3 x 25 mm3
LightBurst Digital Detector
Sensitivity
13.5 cps/kBq NEMA
46,6 cps/kBq Effective
53 kcps @ 2.4 kBq/mL (FDG)
Technology
Digital TOF – 9792x SiPM
385 ps TOF resolution
Coverage
20.0 cm axial FOV
5-6 bed per wholebody
Crystal – LBS
3.95 x 5.3 x 25 mm3
L I G H T B U R S T D I G I T A L D E T E C T O RE N G I N E E R E D F O R P R E C I S I O N
TRUE DISCOVERY DISCOVERY MI LIGHTBURST DIGITAL QUANTITATION DIGITAL INDUSTRIAL SHAPING THE FUTURECLINICAL IMAGES DISCLAIMERSREVOLUTION EVOSCALABILITY
LightBurst Digital Detector Conventional PET
3.95 x 5.3 x 25 mm3
4.2 mm typical resolution
385 ps timing resolution
up
to
5c
m
16
mm
L o w e r R e s o l u t i o n H i g h e r R e s o l u t i o n
S M A L L E R B L O C K D E S I G NR E S O L U T I O N & S E N S I T I V I T Y
TRUE DISCOVERY DISCOVERY MI LIGHTBURST DIGITAL QUANTITATION DIGITAL INDUSTRIAL SHAPING THE FUTURECLINICAL IMAGES DISCLAIMERSREVOLUTION EVOSCALABILITY
Conventional PET
S1 S2 S1 + S2
✗ ✗ ✓
L o w R e s o l u t i o n
H i g h S e n s i t i v i t y
• U P T O 7 5 % O F T H E 5 1 1 K E V P H O T O N C O M P T O N S C AT T E R W I T H I N T H E B L O C K D E T E C T O R
• L O S S O F S E N S I T I V I T Y O N T H E
D E T E C T O R E D G E
• L O S S O F R E S O L U T I O N
C O M P T O N R E C O V E R YR E S O L U T I O N & S E N S I T I V I T Y
TRUE DISCOVERY DISCOVERY MI LIGHTBURST DIGITAL QUANTITATION DIGITAL INDUSTRIAL SHAPING THE FUTURECLINICAL IMAGES DISCLAIMERSREVOLUTION EVOSCALABILITY
LightBurst Digital Detector
S1 = E1 ; T1 ; X1Y1
E1: 211keV
S2 = E2 ; T2 ; X2Y2
E2: 300keV
E1 + E2 ; T1 ; X1Y1✗E1 + E2 = 511keV
H i g h e r R e s o l u t i o n
H i g h e r S e n s i t i v i t y
✗
✓
C o n v e n t i o n a l C o m p t o n R e c o v e r y
Conventional PET
S1 S2 S1 + S2
✗ ✗ ✓
L o w R e s o l u t i o n
H i g h S e n s i t i v i t y
C O M P T O N R E C O V E R YR E S O L U T I O N & S E N S I T I V I T Y
TRUE DISCOVERY DISCOVERY MI LIGHTBURST DIGITAL QUANTITATION DIGITAL INDUSTRIAL SHAPING THE FUTURECLINICAL IMAGES DISCLAIMERSREVOLUTION EVOSCALABILITY
Analog Compton recovery within
the block
Digital Compton recovery from adjacent block
Without Compton
scatter recovery
✓ 20% Sensitivity boost
✓ 20% Peak NECR recovery
✓ 385 ps TOF resolution
✓ ~9.6% energy resolution
L I G H T B U R S T D I G I T A L
C O M P T O N R E C O V E R YR E S O L U T I O N & S E N S I T I V I T Y
TRUE DISCOVERY DISCOVERY MI LIGHTBURST DIGITAL QUANTITATION DIGITAL INDUSTRIAL SHAPING THE FUTURECLINICAL IMAGES DISCLAIMERSREVOLUTION EVOSCALABILITY
18°C PET detector liquid cooling
Temp. sensor & gain control
LightBurst Digital Detector
Q . T E M PA C C U R A C Y & S T A B I L I T Y
TRUE DISCOVERY DISCOVERY MI LIGHTBURST DIGITAL QUANTITATION DIGITAL INDUSTRIAL SHAPING THE FUTURECLINICAL IMAGES DISCLAIMERSREVOLUTION EVOSCALABILITY
A B R I L L I A N T I N T R O D U C T I O N T O A L L D I S C O V E R Y M I C A N D O
White is the primary copy color
Tertiary color
Light gray can be used as a secondary color on dark backgrounds
Dark gray can be used as a secondary color on lighter backgrounds
S i g n i f i c a n t l y b e t t e r s m a l l l e s i o n d e t e c t a b i l i t y 1
U p t o 2 x i m p r o v e m e n t i n v o l u m e t r i c r e s o l u t i o n 1
H i g h e s t N E M A s e n s i t i v i t y o f a n y T O F P E T / C T s y s t e m 2
H i g h e s t N E C R o f a n y T O F P E T / C T s y s t e m 3
TRUE DISCOVERY DISCOVERY MI LIGHTBURST DIGITAL QUANTITATION DIGITAL INDUSTRIAL SHAPING THE FUTURECLINICAL IMAGES DISCLAIMERSREVOLUTION EVOSCALABILITY
2 X I M P R O V E M E N T I N V O L U M E T R I C R E S O L U T I O N 1
Anthropomorphic (Torso) Phantom with 5, 6 and 8 mm spheres in various regions
Reconstruction: VPFXS
D I S C O V E R Y M I
8mm Ø objects clearly visible5 mm Ø clearly visible
65 mm3 volumetric resolution
5 mm
8 mm
6 mm
5 mm
LightBurst Digital Detector
D I S C O V E R Y P E T / C T 7 1 0
8mm Ø objects clearly visible5 mm Ø not visible
268 mm3 volumetric resolution
5 mm
8 mm
6 mm
5 mm
Conventional PET
TRUE DISCOVERY DISCOVERY MI LIGHTBURST DIGITAL QUANTITATION DIGITAL INDUSTRIAL SHAPING THE FUTURECLINICAL IMAGES DISCLAIMERSREVOLUTION EVOSCALABILITY
S M A L L L E S I O N
D E T E C T A B I L I T YConventional PETLightBurst Digital Detector
SUVmax: 4.5Lesion Size: 1cm
SUVmax: 2.1
DISCOVERY MI sensitivity and LightBurst Digital detector simultaneously provides excellent image quality and resolution. Discovery MI provides more confidence when looking for small metastatic disease in difficult areas such as the liver.
1 5 m i n u t e s
2 9 8 M B q / 8 m C i F D G
9 6 m i n u t e u p t a k e
A c q u i s i t i o n
P a t i e n t w i t h h i s t o r y o f
M e l a n o m a r e f e r r e d t o
P E T / C T f o r r e s t a g i n g
a n d m e t a s t a t i c
e v a l u a t i o n
P a t i e n t H i s t o r y
2 2 . 6
P a t i e n t B M I
Follow-up CT
Courtesy Stanford University, A. Iagaru, MD
TRUE DISCOVERY DISCOVERY MI LIGHTBURST DIGITAL QUANTITATION DIGITAL INDUSTRIAL SHAPING THE FUTURECLINICAL IMAGES DISCLAIMERSREVOLUTION EVOSCALABILITY
S M A L L L E S I O N
D E T E C T A B I L I T Y
Courtesy University of Zurich
2 m i n u t e s / F O V
3 2 9 M B q / 8 . 9 m C i F D G
6 5 m i n u t e u p t a k e
A c q u i s i t i o n
P a t i e n t w i t h h i s t o r y o f
H e a d a n d N e c k C a n c e r
r e f e r r e d t o P E T f o r
e v a l u a t i o n o f l y m p h
n o d e i n v o l v e m e n t .
P a t i e n t H i s t o r y
2 5 . 6
P a t i e n t B M I
OSEM 70CM DFOV Hi Res Q.Clear
SUVmax: 5.71 g/ml SUVmax: 10.16 g/ml
TRUE DISCOVERY DISCOVERY MI LIGHTBURST DIGITAL QUANTITATION DIGITAL INDUSTRIAL SHAPING THE FUTURECLINICAL IMAGES DISCLAIMERSREVOLUTION EVOSCALABILITY
U L T R A F A S T A C Q U I S I T I O N
Courtesy University of Zurich
TRUE DISCOVERY DISCOVERY MI LIGHTBURST DIGITAL QUANTITATION DIGITAL INDUSTRIAL SHAPING THE FUTURECLINICAL IMAGES DISCLAIMERSREVOLUTION EVOSCALABILITY
32
GE 2 min / bed14 min Scan
GE 30 sec / bed210 sec Scan
GE 15 sec / bed105 sec Scan
Discovery MI
Size & weight of patient 1.75 m / 80 kg
Injected activity 3.08 MBq/kg
# bed positions / scan length 7 / 1.12 m
A C C E L E R AT E R E S E A R C H
NEMA Sensitivity13.5 cps/kBqNEMA Peak NECR180 kcps @ 20 kBq/mL
NEMA Sensitivity7.5 cps/kBqNEMA Peak NECR130 kcps @ 30 kBq/ml
▪ I N C R E A S E L O W - Y I E L D T R A C E R
C A P A B I L I T Y W I T H O U T
I M P A C T I N G I M A G E Q U A L I T Y
A N D S M A L L L E S I O N
D E T E C TA B I L I T Y 1
▪ P U R S U E G R O U N D B R E A K I N G
R E S E A R C H W I T H F A S T E R
D E C A Y I N G T R A C E R S
TRUE DISCOVERY DISCOVERY MI LIGHTBURST DIGITAL QUANTITATION DIGITAL INDUSTRIAL SHAPING THE FUTURECLINICAL IMAGES DISCLAIMERSREVOLUTION EVOSCALABILITY
R E V O L U T I O N E V O
Dual Energy
Performix 40 Plus tube
HighlightClarity detector
P e r f o r m i x 4 0 P l u s t u b e
A S i R - V
D u a l E n e r g y
S m a r t M A R
H i L i g h t C l a r i t y D e t e c t o r
D e s i g n e d f o r t h e m o s t d e m a n d i n g e x a m s – 0 . 3 5 s i n r o u t i n e
U p t o 8 2 % r e d u c t i o n i n C T d o s e a t s a m e i m a g e q u a l i t y 4 , 5
T i s s u e c h a r a c t e r i z a t i o n u s i n g C T D u a l E n e r g y t e c h n i q u e w i t h A W
M e t a l A r t i f a c t R e d u c t i o n f o r e v e r y P E T / C T e x a m
4 4 % l o w e r e l e c t r o n i c n o i s e t h a n p r e v i o u s g e n e r a t i o n
TRUE DISCOVERY DISCOVERY MI LIGHTBURST DIGITAL QUANTITATION DIGITAL INDUSTRIAL SHAPING THE FUTURECLINICAL IMAGES DISCLAIMERSREVOLUTION EVOSCALABILITY
0 . 3 5 s e cI N R O U T I N E E X A M S
Gated acquisition
• 0.35 sec/rot
• Cardiac pitch
• 63-68 BPM
Helical acquisition:• 0.35 sec/rot• 1.531 pitch• 2.5 sec scan
Total acquisition• 4.43 mGy CTDIvol• 942 mGy-cm DLP• Iodine: 80 cc @ 4.0 cc/s • Saline: 40 cc @ 3.0 cc/s
Gated
Non-gated
TAVI planning in 14 sec with single contrast injection
TRUE DISCOVERY DISCOVERY MI LIGHTBURST DIGITAL QUANTITATION DIGITAL INDUSTRIAL SHAPING THE FUTURECLINICAL IMAGES DISCLAIMERSREVOLUTION EVOSCALABILITY
Ultra-low-dose chest (0.08 mSv) reconstruction with filtered back-projection
Same study reconstructed using ASiR-V
Up to 82% reduced dose 4,5
In routine imaging, ASiR-V has been shown to reduce dose by up to 82% compared to standard FBP reconstruction at the same image quality.
82%Lower dose
Obtained using a chest factor of 0.014*DLP
A S I R - VI N R O U T I N E E X A M S
TRUE DISCOVERY DISCOVERY MI LIGHTBURST DIGITAL QUANTITATION DIGITAL INDUSTRIAL SHAPING THE FUTURECLINICAL IMAGES DISCLAIMERSREVOLUTION EVOSCALABILITY
Acquisition09/09/14
100 kV
BMI 24
Helical
Standard kernel
ASiR-V 40%
5.0 mGy-cm DLP
Acquisition 09/02/14
120 kV
BMI 24
Helical
Standard kernel
ASiR 50%
12.2 mGy-cm DLP
ASiR-V – Revolution EVOASiR - Optima CT 660)
A S I R - VI N R O U T I N E E X A M S
TRUE DISCOVERY DISCOVERY MI LIGHTBURST DIGITAL QUANTITATION DIGITAL INDUSTRIAL SHAPING THE FUTURECLINICAL IMAGES DISCLAIMERSREVOLUTION EVOSCALABILITY
Smart MARConventional CT
A V A I L A B L E F O R A L L E X A M S
• O N L Y O N E S C A N , R E A L T I M E R E C O N T R U C T I O N
• P R O J E C T I O N B A S E D T E C H N I Q U E F O R B E S T
A C C U R A C Y
• F U L L V E R S AT I L I T Y : H I P I M P L A N T S , D E N TA L F I L L I N G S , S C R E W S O R O T H E R M E TA L I N T H E B O D Y
S M A R T M A RM E T A L A R T I F A C T R E D U C T I O N
TRUE DISCOVERY DISCOVERY MI LIGHTBURST DIGITAL QUANTITATION DIGITAL INDUSTRIAL SHAPING THE FUTURECLINICAL IMAGES DISCLAIMERSREVOLUTION EVOSCALABILITY
S M A L L L E S I O N
D E T E C T A B I L I T YConventional PETLightBurst Digital Detector
SUVmax: 4.5Lesion Size: 1cm
SUVmax: 2.1
DISCOVERY MI sensitivity and LightBurst Digital detector simultaneously provides excellent image quality and resolution. Discovery MI provides more confidence when looking for small metastatic disease in difficult areas such as the liver.
1 5 m i n u t e s
2 9 8 M B q / 8 m C i F D G
9 6 m i n u t e u p t a k e
A c q u i s i t i o n
P a t i e n t w i t h h i s t o r y o f
M e l a n o m a r e f e r r e d t o
P E T / C T f o r r e s t a g i n g
a n d m e t a s t a t i c
e v a l u a t i o n
P a t i e n t H i s t o r y
2 2 . 6
P a t i e n t B M I
Follow-up CT
Courtesy Stanford University, A. Iagaru, MD
TRUE DISCOVERY DISCOVERY MI LIGHTBURST DIGITAL QUANTITATION DIGITAL INDUSTRIAL SHAPING THE FUTURECLINICAL IMAGES DISCLAIMERSREVOLUTION EVOSCALABILITY
S M A L L L E S I O N
D E T E C T A B I L I T Y
Courtesy University of Zurich
1 5 m i n u t e s
2 9 8 M B q / 8 m C i F D G
9 6 m i n u t e u p t a k e
A c q u i s i t i o n
P a t i e n t w i t h h i s t o r y o f
M e l a n o m a r e f e r r e d t o
P E T / C T f o r r e s t a g i n g
a n d m e t a s t a t i c
e v a l u a t i o n
P a t i e n t H i s t o r y
2 2 . 6
P a t i e n t B M I
OSEM 70CM DFOV Hi Res Q.Clear
TRUE DISCOVERY DISCOVERY MI LIGHTBURST DIGITAL QUANTITATION DIGITAL INDUSTRIAL SHAPING THE FUTURECLINICAL IMAGES DISCLAIMERSREVOLUTION EVOSCALABILITY
C L I N I C A L E X C E L L E N C E
A N D E X P A N S I O N
Courtesy Stanford University, A. Iagaru, MD
Conventional CTSmart MAR
(metal Artefact Reduction)
Seamlessly apply SmartMAR on every patient to improve CT image quality and confidence in localizing disease in the pelvis.
TRUE DISCOVERY DISCOVERY MI LIGHTBURST DIGITAL QUANTITATION DIGITAL INDUSTRIAL SHAPING THE FUTURECLINICAL IMAGES DISCLAIMERSREVOLUTION EVOSCALABILITY
C O N T R A S T A N D R E S O L U T I O N
F O R A L L P E T T R A C E R S
Courtesy Stanford University, A. Iagaru, MD
Low noise imaging demonstrate excellent image Quality
Excellent image quality and small lesions detectability
Ga-68 DOTATATE
Left- 6 mCi / 222 MBq Injection- 78 min uptake- 2.6mCi / 96 MBq at Scan Time
Right- 6.7 mCi / 248 MBq Injection- 104 min uptake- 2.2 mCi / 81 MBq at scan time
PET Radiopharmaceutical may not be approved by ministers of health in all regions
TRUE DISCOVERY DISCOVERY MI LIGHTBURST DIGITAL QUANTITATION DIGITAL INDUSTRIAL SHAPING THE FUTURECLINICAL IMAGES DISCLAIMERSREVOLUTION EVOSCALABILITY
½ T I M E , N O C O M P R O M I S E
Courtesy Stanford University, A. Iagaru, MD
½ acquisition time6 min
Full acquisition time12 min
SUVmax: 7.45 Liver SUVmean: 2.07 SUVmax: 7.53 Liver SUVmean: 2.01
½ acquisition time6 min
Full acquisition time12 min
DISCOVERY MI sensitivity and LightBurst Digital detector provide reliable and consistent image quality, resolution and quantitative accuracy. With Discovery MI, research center will be able to free up scanner time for their research study without impact their daily clinical workload.
TRUE DISCOVERY DISCOVERY MI LIGHTBURST DIGITAL QUANTITATION DIGITAL INDUSTRIAL SHAPING THE FUTURECLINICAL IMAGES DISCLAIMERSREVOLUTION EVOSCALABILITY
S M A L L L E S I O N D E T E C T A B I L I T Y
Courtesy Stanford University, A. Iagaru, MD
SUVmax: 3.7SUVmax: 7.4
LightBurst Digital Conventional PETLightBurst Digital Conventional PET
DISCOVERY MI sensitivity and LightBurst Digital detector provide improvement in small lesion detectability giving you increased confidence in your communications to referring physicians.
TRUE DISCOVERY DISCOVERY MI LIGHTBURST DIGITAL QUANTITATION DIGITAL INDUSTRIAL SHAPING THE FUTURECLINICAL IMAGES DISCLAIMERSREVOLUTION EVOSCALABILITY
E X C E L L E N T I M A G E Q U A L I T Y
A N D C L I N I C A L R E S O L U T I O N
Courtesy Stanford University, A. Iagaru, MD
Liver SUVmean: 2.22 g/ml
Liver Noise (STD): 0.17 g/ml
DISCOVERY MI sensitivity and 20cm Axial Field of View LightBurst Digital detector provide the ability to perform fast 2 meter scans without sacrificing image quality or resolution and improve patient comfort with shorter scan times.
2 0 m i n u t e s
3 8 3 M B q / 1 0 . 3 5 m C i F D G
9 6 m i n u t e u p t a k e
A c q u i s i t i o n
P a t i e n t r e f e r r e d t o P E T / C T f o r
R e s t a g i n g o f M a n t l e C e l l N o n -
H o d g k i n ’ s L y m p h o m a
P a t i e n t H i s t o r y
2 8 . 4
P a t i e n t B M I
TRUE DISCOVERY DISCOVERY MI LIGHTBURST DIGITAL QUANTITATION DIGITAL INDUSTRIAL SHAPING THE FUTURECLINICAL IMAGES DISCLAIMERSREVOLUTION EVOSCALABILITY
E X C E L L E N T I M A G E Q U A L I T Y
A N D C L I N I C A L R E S O L U T I O N
Courtesy Stanford University, A. Iagaru, MD
1 0 m i n u t e s
3 8 8 M B q / 1 0 . 5 m C i F D G
7 7 m i n u t e u p t a k e
A c q u i s i t i o n
P a t i e n t r e f e r r e d t o P E T / C T f o r
e v a l u a t i o n a n d l o c a l i z a t i o n o f
e p i l e p s y f o c i
P a t i e n t H i s t o r y
3 0 . 1
P a t i e n t B M I DISCOVERY MI sensitivity and 20cm Axial Field of View LightBurst Digital detector provide the excellent image quality and clinical resolution necessary for complex neurology cases where the slightest changes in uptake can be the guide for Neurosurgeons.
TRUE DISCOVERY DISCOVERY MI LIGHTBURST DIGITAL QUANTITATION DIGITAL INDUSTRIAL SHAPING THE FUTURECLINICAL IMAGES DISCLAIMERSREVOLUTION EVOSCALABILITY
C O N T R A S T A N D R E S O L U T I O N
F O R A L L P E T T R A C E R S
Low noise imaging demonstrate excellent image qualityCourtesy PET Center Uppsala
A c q u i s i t i o n
P a t i e n t H i s t o r y
Patient referred to PET/CT for evaluation of Alzheimer’sdiseases
1 9 6 M B q / 5 . 3 m C i F D G
6 7 m i n u t e u p t a k e
TRUE DISCOVERY DISCOVERY MI LIGHTBURST DIGITAL QUANTITATION DIGITAL INDUSTRIAL SHAPING THE FUTURECLINICAL IMAGES DISCLAIMERSREVOLUTION EVOSCALABILITY
E X C E L L E N T I M A G E Q U A L I T Y
A N D C L I N I C A L R E S O L U T I O N
Courtesy Stanford University, A. Iagaru, MD
2 0 m i n u t e s
2 7 0 M B q / 7 . 3 m C i 1 8 F - N a F
1 1 3 m i n u t e u p t a k e
A c q u i s i t i o n
P a t i e n t w i t h h i s t o r y o f P r o s t a t e
c a n c e r r e f e r r e d t o P E T / C T f o r
H i s t o r y o f p r o s t a t e c a n c e r w i t h
n e w b o n e p a i n . E v a l u a t i o n o f
m e t a s t a t i c d i s e a s e .
P a t i e n t H i s t o r y
2 7 . 4
P a t i e n t B M I
DISCOVERY MI sensitivity and clinical resolution provide small lesion detectability for small bone lesions.
PET Radiopharmaceutical may not be approved by ministers of health in all regions
TRUE DISCOVERY DISCOVERY MI LIGHTBURST DIGITAL QUANTITATION DIGITAL INDUSTRIAL SHAPING THE FUTURECLINICAL IMAGES DISCLAIMERSREVOLUTION EVOSCALABILITY
S M A L L L E S I O N D E T E C T A B I L I T Y
Courtesy PET Center Uppsala
A c q u i s i t i o n
P a t i e n t H i s t o r y
P a t i e n t r e f e r r e d t o P E T / C T f o r e v a l u a t i o n o f m e t a s t a t i c p r o s t a t e c a n c e r .
2 6 . 7
P a t i e n t B M I
1 2 m i n u t e s
2 7 0 M B q / 7 . 3 m C i 1 8 F - N a F
1 1 3 m i n u t e u p t a k e
PET Radiopharmaceutical may not be approved by ministers of health in all regions
TRUE DISCOVERY DISCOVERY MI LIGHTBURST DIGITAL QUANTITATION DIGITAL INDUSTRIAL SHAPING THE FUTURECLINICAL IMAGES DISCLAIMERSREVOLUTION EVOSCALABILITY
Grow patient volumes as referring physicians value the accurate, reproducible results and diagnostic confidence you deliver
QUANTITATIVE SUV YOU AND YOUR PATIENTS CAN TRUST
Improve communication with improved quantitation
More accurately assess treatment response to guide your treatment planning decisions with more accurate SUVs
TRUE DISCOVERY DISCOVERY MI LIGHTBURST DIGITAL QUANTITATION DIGITAL INDUSTRIAL SHAPING THE FUTURECLINICAL IMAGES DISCLAIMERSREVOLUTION EVOSCALABILITY
Instrumentation
Physiology~15%
~35%
SUV
Calibration/QC
PVE
Motion
Reconstruction
Segmentation
Q.SUV
Q U A N T I T A T I V E P E T C H A L L E N G E S
TRUE DISCOVERY DISCOVERY MI LIGHTBURST DIGITAL QUANTITATION DIGITAL INDUSTRIAL SHAPING THE FUTURECLINICAL IMAGES DISCLAIMERSREVOLUTION EVOSCALABILITY
FBP
2D/3D
VUE POINT
OSEM - HD OSEM - TOF OSEM - TOF + PSF
Q.CLEAR
BSREM
I M A G E Q U A L I T YI M A G E Q U A L I T Y
& Q U A N T I T A T I O N
I T E R A T I V E R E C O N S T R U C T I O N
TRUE DISCOVERY DISCOVERY MI LIGHTBURST DIGITAL QUANTITATION DIGITAL INDUSTRIAL SHAPING THE FUTURECLINICAL IMAGES DISCLAIMERSREVOLUTION EVOSCALABILITY
IMAGE QUALITY DETERIORATES WITH MORE THAN A FEW ITERATIONS
1 Iteration 2 Iterations 15 terations 25 Iterations
BMI: 52.5 | ROI: 15mm | OSEM
SNR: 14.0 SNR: 8.0 SNR: 7.1
SUV 4.2 SUV 8.2 SUV 12.8
SNR : 16.4
SUV 13.5
I T E R A T I V E R E C O N S T R U C T I O N C H A L L E N G E S
TRUE DISCOVERY DISCOVERY MI LIGHTBURST DIGITAL QUANTITATION DIGITAL INDUSTRIAL SHAPING THE FUTURECLINICAL IMAGES DISCLAIMERSREVOLUTION EVOSCALABILITY
FULL CONVERGENCE PET RECONSTRUCTION
2 Iterations 25 Iterations 25 Iterations
SUV 8.2 SUV 13.5 Q.SUV 14.0
BMI: 52.5 | ROI: 15mm | OSEM
SNR: 16.4 SNR: 35.0SNR : 7.1
Q . C L E A R A N D Q . S U V
TRUE DISCOVERY DISCOVERY MI LIGHTBURST DIGITAL QUANTITATION DIGITAL INDUSTRIAL SHAPING THE FUTURECLINICAL IMAGES DISCLAIMERSREVOLUTION EVOSCALABILITY
MORE ACCURATE AND CONSISTENT QUANTITATION WITHINTELLIGENT NOISE CONTROL. EVERY VOXEL. EVERY STEP.
No noise control
One-size-fits-all noise control
Scanner Modeling
Object Modeling Filter
Partially converged SUVs
Recon LoopRecon Loop-3x 25x
Compromised image quality
Conventional Iterative Reconstruction Q.Clear
C O N S I S T E N T Q U A N T I T A T I O N
Noise Modeling
Scanner Modeling
Object Modeling
TRUE DISCOVERY DISCOVERY MI LIGHTBURST DIGITAL QUANTITATION DIGITAL INDUSTRIAL SHAPING THE FUTURECLINICAL IMAGES DISCLAIMERSREVOLUTION EVOSCALABILITY
UP TO 2X IMPROVEMENT IN IMAGE QUALITY (SNR)
Standard
Q.Clear
Q.Clear
18F-FDG 3D MIP PET View
Images acquired on Discovery IQ equivalent system
• I N C R E A S E C L I N I C A L S E N S I T I V I T Y
• C O N F I D E N T L Y D E T E C T S M A L L M E TA S TAT I C D I S E A S E
• I M P R O V E D Q U A N T I TAT I V E A C C U R A C Y
C O N S I S T E N T Q U A N T I T A T I O N
TRUE DISCOVERY DISCOVERY MI LIGHTBURST DIGITAL QUANTITATION DIGITAL INDUSTRIAL SHAPING THE FUTURECLINICAL IMAGES DISCLAIMERSREVOLUTION EVOSCALABILITY
SUV difference between Q.Clear and OSEM (TOF+PSF)
Partial volume error reduction
-2.0 g/mL 2.0 g/mL
F U L L C O N V E R G E N C E
N O C O M P R O M I S E
TRUE DISCOVERY DISCOVERY MI LIGHTBURST DIGITAL QUANTITATION DIGITAL INDUSTRIAL SHAPING THE FUTURECLINICAL IMAGES DISCLAIMERSREVOLUTION EVOSCALABILITY
Q . S T A T I C
One-click PET protocolwith prospective reconstruction
Based on static WB workflowfor a static image series output
Reduces motion blurringfor quantitative consistency
TRUE DISCOVERY DISCOVERY MI LIGHTBURST DIGITAL QUANTITATION DIGITAL INDUSTRIAL SHAPING THE FUTURECLINICAL IMAGES DISCLAIMERSREVOLUTION EVOSCALABILITY
Static PET 4D-PET Q.Freeze
SPHERES MOTIONSPHERES SUV RECOVERY SPHERES VOLUME RECOVERY
Q . F R E E Z EO N E I M A G E . A L L T H E C O U N T S . M O T I O N E L I M I N A T E D .
TRUE DISCOVERY DISCOVERY MI LIGHTBURST DIGITAL QUANTITATION DIGITAL INDUSTRIAL SHAPING THE FUTURECLINICAL IMAGES DISCLAIMERSREVOLUTION EVOSCALABILITY
Q.FreezeWhole-body PET/CT Integrated 4D PET/CT
SUV = 4.2 g/mL SUV = 12 g/mL
10 min 24 min 12 min
Axial FOV: 15.6 cm Overlap: 23%TotalFOV: 28 cm
Q . F R E E Z EF U L L T H O R A X C O V E R A G E F O R E V E R Y P A T I E N T
TRUE DISCOVERY DISCOVERY MI LIGHTBURST DIGITAL QUANTITATION DIGITAL INDUSTRIAL SHAPING THE FUTURECLINICAL IMAGES DISCLAIMERSREVOLUTION EVOSCALABILITY
SUV 3.8 g/mL SUV 3.7 g/mL
Best 4D bin
Whole-body PET/CT Integrated 4D PET/CT Q.Freeze
Q . F R E E Z EF U L L T H O R A X C O V E R A G E F O R E V E R Y P A T I E N T
TRUE DISCOVERY DISCOVERY MI LIGHTBURST DIGITAL QUANTITATION DIGITAL INDUSTRIAL SHAPING THE FUTURECLINICAL IMAGES DISCLAIMERSREVOLUTION EVOSCALABILITY