Posted at the Institutional Resources for Unique Collection and Academic Archives at Tokyo Dental College, Available from http://ir.tdc.ac.jp/ Title Discoloration of Ti-20Cr alloy in oral environment and its surface characterization Author(s) Alternative Takemoto, S; Tasaka, A; Hattori, M; Sakurai, K; Oda, Y Journal Dental materials journal, 31(6): 1060-1067 URL http://hdl.handle.net/10130/2994 Right

Discoloration of Ti-20Cr alloy in oral environment Takemoto, S; …ir.tdc.ac.jp/irucaa/bitstream/10130/2994/1/31_2012-195.pdf · 2013-03-12 · Discoloration of Ti-20Cr alloy in oral

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Discoloration of Ti-20Cr alloy in oral environment Takemoto, S; …ir.tdc.ac.jp/irucaa/bitstream/10130/2994/1/31_2012-195.pdf · 2013-03-12 · Discoloration of Ti-20Cr alloy in oral

Posted at the Institutional Resources for Unique Collection and Academic Archives at Tokyo Dental College,

Available from http://ir.tdc.ac.jp/

TitleDiscoloration of Ti-20Cr alloy in oral environment

and its surface characterization

Author(s)

Alternative

Takemoto, S; Tasaka, A; Hattori, M; Sakurai, K;

Oda, Y

Journal Dental materials journal, 31(6): 1060-1067

URL http://hdl.handle.net/10130/2994

Right

Page 2: Discoloration of Ti-20Cr alloy in oral environment Takemoto, S; …ir.tdc.ac.jp/irucaa/bitstream/10130/2994/1/31_2012-195.pdf · 2013-03-12 · Discoloration of Ti-20Cr alloy in oral

INTRODUCTION

Dental alloys are exposed to an extremely corrosive environment in which humidity is high, pH varies widely due to consumption of food and drink and there are frequent changes in temperature. In some cases, corrosion causes not only allergic reaction due to release of metal ions into the saliva, but also a decrease in mechanical strength and esthetic quality1-4).

Surface analysis has shown evidence of corrosion products on discolored prosthetic devices5-10). Gold and silver-palladium-copper-gold alloys have been reported to show evidence of corrosion due to production of sulfide and hydrogen sulfate by bacteria and the formation of an oxide layer has been observed on silver-based alloys5,6,9,10). It is possible that the composition of alloys and surface characteristics of restorations, configuration of the attached prosthetic device, and particular oral environment play a role in such corrosion. However, the relationship between discoloration and corrosion of dental alloys remains to be clarified.

Titanium (Ti) and its alloys are widely used in the orthopedic and dental fields due to their superior biocompatibility. A number of studies, however, have reported problems associated with discoloration5,7,8,11-19). Titanium implants showed fracture due to corrosive products, and crowns and denture bases made of Ti alloys showed discoloration7,8,17). Discoloration and corrosion of Ti alloys occurs with exposure to fluoride in prophylactic agents11-13,18-20) or peroxides generated by macrophages or peroxide-containing denture cleansers8,14-16). On the other hand, some Ti alloys have shown good resistance to corrosion by fluoride or peroxide21-24). In earlier studies by our group, binary Ti-20mass% chromium (Ti-20Cr) alloys showed superior resistance to corrosion by fluoride or peroxide in vitro22-24). However, the corrosion behavior of Ti-20Cr alloys in an oral environment remains to be clarified.

The objective of this study was to investigate resistance to discoloration by Ti-20Cr alloys in an oral environment by determining degree of change in color in Ti or cobalt-chromium alloys in situ. Resistance to corrosion was also compared among discolored Ti alloys in terms of chemical change. The influence of the oral environment is also discussed.

MATERIALS AND METHODS

Alloy specimensFour types of alloy were prepared (Table 1): Commercially pure Ti (TI: T-alloy M, GC, Tokyo, Japan), Ti-6Al-7Nb (TNB: T-alloy tough, GC, Japan), Co-29.5Cr-5Mo alloys (COCR: Wironium, BEGO, Germany), and experimental Ti-20Cr made of sponge Ti (99.8% or above, OSAKA Titanium technologies, Hyogo, Japan) and pure chromium (99.99%, JMC New Materials Inc., Tokyo, Japan) in an argon-arc melting furnace (ACM-01, Diavac, Chiba, Japan).

All specimens (8 mm in diameter and 1 mm in thickness) were arc-melted and cast using an argon-arc melting/pressure casting machine (Cyclarc II, J. Morita, Kyoto, Japan), as described in the literature22). Each specimen was polished with abrasive paper according to the standard metallurgical procedure. Polishing was completed with 0.02-µm colloidal silica particles and ultrasonic washing in acetone and distilled water for 10 min.

Preparation of palatal plate Ten healthy dentulous volunteers (5 men and 5 women, range 25–35 years, mean age 28.8±2.7 years) were enrolled in the study. Informed consent was obtained from each volunteer in accordance with the guidelines of the Ethics Committee of Tokyo Dental College (#212). Individual palatal plates were made of commercial heat-curing acrylic resin (Acron, GC) for dentures. Four hollows, 10 mm in diameter and 1 mm in thickness,

Discoloration of Ti-20Cr alloy in oral environment and its surface characterizationShinji TAKEMOTO1, Akinori TASAKA2, Masayuki HATTORI1, Kaoru SAKURAI2 and Yutaka ODA1

1 Department of Dental Materials Science, Tokyo Dental College, 1-2-2 Masago, Mihama-ku, Chiba 261-8502, Japan2 Department of Removable Prosthodontics and Gerodontology, Tokyo Dental College, 1-2-2 Masago, Mihama-ku, Chiba 261-8502, JapanCorresponding author, Shinji TAKEMOTO; E-mail: [email protected]

The objective of this study was to evaluate change in color in experimental titanium-20mass% chromium (Ti-20Cr) alloy in an oral environment. Pure Ti and Ti-6Al-7Nb and Co-29Cr-5Mo alloys, as references to compare change in color, were prepared by casting. The cast specimen was mirror-polished. Each specimen was affixed to a palatal plate and the plate then worn by a volunteer for up to 300 h. A few specimens showed a change in color. These changes and the median values among the tested alloys were not significant. Larger amounts of carbon, nitrogen, and oxygen were observed in the discolored alloys than in the slightly-discolored alloys. The spectra of the constituent elements of the alloys revealed no corrosion. In conclusion, the experimental Ti-20Cr alloys showed a level of resistance to change in color and corrosion similar to that in commercially available Ti and Co-29Cr-5Mo alloys.

Keywords: Titanium alloy, Surface characterization, Corrosion, Surface oxide film, Oral environment

Received Jul 23, 2012: Accepted Sep 12, 2012doi:10.4012/dmj.2012-195 JOI JST.JSTAGE/dmj/2012-195

Dental Materials Journal 2012; 31(6): 1060–1067

Page 3: Discoloration of Ti-20Cr alloy in oral environment Takemoto, S; …ir.tdc.ac.jp/irucaa/bitstream/10130/2994/1/31_2012-195.pdf · 2013-03-12 · Discoloration of Ti-20Cr alloy in oral

were made between the first and second premolars and between the first and second molars on each palatal plate to allow attachment of alloy specimens with acrylic resin (Unifast II, GC). Figure 1(a) shows the four alloy specimens. Figure 1(b) shows the palatal plate within the oral environment.

Exposure to oral environmentEach volunteer wore one of the prepared palatal plates with attached alloy specimens. During the experimental period, 1) no denture cleansers were used to wash the palatal plate, 2) no fluoride-containing toothpaste or gargle solution was used, 3) food and drink were consumed with the plate in place, and 4) the plate was corrected after 100, 200, and 300 h of wear.

EvaluationSaliva was evaluated by semi-quantitative evaluation of microorganisms and for buffering effect and pH. The Rezazurin Disc test (RD test: Showa Yakuhin, Tokyo, Japan), MSB broth (Mucount: Showa Yakuhin), and microbial culture in specific agar medium (Dentrocult LB: Oral Care Inc., Tokyo and CHROMagarTM Candida, Kanto Reagents Ltd., Tokyo, Japan) were used to detect Lactobacillus, Streptococcus mutans, and Candida species. Buffering capacity and pH of saliva were investigated using reagent (Dentobuff StripTM, Oral Care Inc., Tokyo, Japan) and a pH meter (Twin, Horiba, Kyoto, Japan). Measurements were performed according

to the manufacturer’s instructions.The color value of the specimens was determined

with a color meter (MCR-A, Luck Office, Tokyo, Japan) at before and after exposure to the oral environment according to the CIE L*a*b* color coordinator system. Specimens were removed from the palatal plate after 100, 200, or 300 h exposure and ultrasonically washed in water. Specimens were re-mounted on the palatal plate with resin after each measurement. An area 6 mm in diameter was used for measurements. The color value of each specimen was then measured again to determine change in color. Color difference, ΔE*ab, was calculated using the following equation:

ΔE*ab=[(Lx*−L0*)2+ (ax*−a0*)2 + (bx*−b0*)2]1/2

where L0*, a0* and b0* are values at before exposure to the oral environment and Lx*, ax* and bx* are values at after exposure, and x indicates exposure time.

After 300 h, some specimens were analyzed using scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS). Surface morphology was determined by observation under a field emission SEM (FE-SEM; ERA-8900FE, Elionix, Tokyo, Japan). Accelerating voltage was 15 kV. The XPS analysis was performed using a photoelectron spectroscope (Axis-Ultra, Kratos-Shimadzu, Kyoto, Japan). The X-ray resource was monochronized Al Kα (filament voltage: 15 kV, emission current: 10 mA), the area of measurement

Fig. 1 Mirror-polished specimens and palatal plate with attached specimens in oral environment.

Table 1 Code and nominal composition of alloys

Alloy Composition (mass%) Brand Manufacturer Code

Ti-20Cr Ti-20Cr Experimental TCR

Grade2-Ti Ti>99.5 T-ALLOY M GC TI

Ti-6Al-7Nb 86.5Ti-7Nb-6Al-0.5Bal T-ALLOY TOUGH GC TNB

Co-Cr-Mo 63Co-29.53Cr-5Mo<2% other WIRONIUM BEGO COCR

1061Dent Mater J 2012; 31(6): 1060–1067

Page 4: Discoloration of Ti-20Cr alloy in oral environment Takemoto, S; …ir.tdc.ac.jp/irucaa/bitstream/10130/2994/1/31_2012-195.pdf · 2013-03-12 · Discoloration of Ti-20Cr alloy in oral

was 200×600 µm, and take-off angle of photoelectrons was 90°.

Statistical analysisStatistical analysis of ΔE*ab was performed by a two-way analysis of variance (α=0.05) to determine the effects of exposure time and type of alloy. Comparisons were then made with the Bonferroni test. Statistical significance was set at α=0.05.

RESULTS

Saliva condition in volunteersVolume of saliva ranged from 0.6 to 2.4 mL/min (average 1.48 mL/min). Salivary bacteria count revealed large numbers of S. mutans, but low activity for Candida and Lactobacilli species. The average pH of the saliva was 8.0, a little on the high side. Saliva showed a high buffering capacity, indicating that the acid generated by bacterial metabolism was being diluted due to salivary buffering capacity.

Change in colorFigure 2 shows the ΔE*ab of each alloy by period of exposure. The ΔE*ab of the TCR specimens ranged from 0.2 to 10.5, and the median value after exposure for 100, 200, and 300 h was 1.7, 1.0, and 1.4, respectively. The ΔE*ab of TI ranged from 0.5 to 9.9. The median value for the TI specimens after exposure for 100, 200, and 300 h was 2.2, 1.5, and 3.5, respectively. The ΔE*ab of the TNB specimen ranged from 0.4 to 12.0, and the median value after exposure for 100, 200, and 300 h was 1.5, 1.3, and 1.0, respectively. The ΔE*ab of the COCR specimens ranged from 0.1 to 8.1, and the median value after exposure for 100, 200, and 300 h was 0.8, 0.6, and 0.8, respectively. No significant difference was observed in the ΔE*ab value for each alloy among exposure periods (p>0.05).

SEM observationFigure 3 shows typical SEM images of the discolored TCR, TI, TNB, and COCR specimens after exposure to the oral environment for 300 h. No corrosion was observed in any specimen. As shown in Figs. 3(a)–(c), a thin adhesive film appears to have formed on some areas of the titanium alloys. The film had peeled from the alloy surface in some areas. On the other hand, a thinner film was observed in the COCR specimens than in the others, as shown in Fig. 3(d).

Surface composition and chemical stateAs shown in Fig. 2, although the median ΔE*ab was less than 3 except for TI for 300 h, some specimens showed discoloration (ΔE*ab>6). Table 2 lists detected elements in those specimens showing little or large amounts of discoloration in comparison with polished alloys as a reference. Elements detected on the polished alloys included elements of those alloys, including carbon, oxygen, and traces of nitrogen. Nitrogen and carbon were strongly detected, as were calcium and phosphorus as trace elements after exposure to the oral environment. Figure 4 shows the Ti2p, Cr2p, C1s, O1s, N1s XPS spectra of the TCR specimens, which were mirror-polished, after exposure for 300 h. The Ti2p peak was decomposed to four doublets of Ti0, Ti2+, Ti3+, and Ti4+, originating from metal and surface oxide (passive film). These four components were confirmed on the mirror-polished, slightly-discolored and discolored TCR specimens. Similarly, the Cr2p peak of the discolored TCR specimen was also decomposed to metal and oxide peaks, as were those of the mirror-polished and slightly-discolored specimens, as shown in Fig. 4(b). These Ti2p and Cr2p spectra suggested that the surface of the TCR was covered with passive film consisting of

Fig. 2 Change in color in alloys after exposure to oral environment for 100, 200, or 300 h.

Fig. 3 SEM images of discolored specimens after exposure to oral environment for 300 h.

(a) TCR, (b) TI, (c) TNB, (d) COCR

1062 Dent Mater J 2012; 31(6): 1060–1067

Page 5: Discoloration of Ti-20Cr alloy in oral environment Takemoto, S; …ir.tdc.ac.jp/irucaa/bitstream/10130/2994/1/31_2012-195.pdf · 2013-03-12 · Discoloration of Ti-20Cr alloy in oral

titanium and chromium oxides, regardless of degree of discoloration. Judging from the metal states detected in the Ti2p and Cr2p spectra, the passive film was thin. Decomposition of hydrocarbon (C-C, C-H) was mainly observed, along with hydroxyl and carbonyl carbons (C-OH, C=O) to a lesser degree in the C1s peak shown in Fig. 4(c). In comparison with in mirror-polished TCR, hydroxyl and carbonyl carbons in the slightly-discolored or discolored TCR specimens yielded a large shoulder or

peak. A comparison of O1s peaks is shown in Fig. 4(d). The profile of the discolored TCR specimens was quite different from those of the mirror-polished or slightly-discolored specimens. The O1s peaks consist of at least three peaks originating from oxide (O2−) hydroxide or hydroxyl (OH−) or hydrate and/or adsorbed water (H2O). Therefore, the discolored TCR specimens had a much higher fraction of OH− and H2O groups than the others. As shown in Fig. 4(e), the N1s spectra showed that the

Table 2 Detected elements on mirror-polished, slightly- discolored, and much discolored specimens at before and after exposure to oral environment for 300 h

TCR TI TNB COCR

Mirror polishedTi, Cr

O, C, NT

TiO, C, NT

Ti, Al, NbO, C, NT

Co, Cr, MoO, C, NT

Slight discoloredTi, Cr

O, C, N, Ca, PTi

O, C, N, Ca, PTi, Al, Nb

O, C, N, Ca, PCo, Cr, Mo

O, C, N, Ca, P

Much discoloredTi, CrT

O, C, N, CaT, PT

TiO, C, N, CaT, PT

Ti, NbT

O, C, NCoT, CrT, MoT

O, C, N

T: Trace detection

Fig. 4 Typical XPS spectra of mirror-polished, slightly-discolored, and much discolored TCR specimens at before and after exposure to oral environment for 300 h.

(a) Ti2p, (b) Cr2p, (c) C1s, (d) O1s, (e) N1s

1063Dent Mater J 2012; 31(6): 1060–1067

Page 6: Discoloration of Ti-20Cr alloy in oral environment Takemoto, S; …ir.tdc.ac.jp/irucaa/bitstream/10130/2994/1/31_2012-195.pdf · 2013-03-12 · Discoloration of Ti-20Cr alloy in oral

Fig. 5 Typical XPS spectra of mirror-polished, slightly-discolored, and much discolored TNB specimens at before and after exposure to oral environment for 300 h.

(a) Ti2p, (b) Nb3d, (c) Al2p

Fig. 6 Typical XPS spectra of mirror-polished, slightly-discolored, and much discolored COCR specimens at before and after exposure to oral environment for 300 h.

(a) Co2p, (b) Cr2p, (c) Mo3d

slightly-discolored and discolored TCR specimens had larger peaks than the mirror-polished ones. These peaks originated in amino and amide groups in proteins or amino acids.

Analysis of the constituent elements is important in determining the level of corrosion in an alloy. Figures 5 and 6 show the XPS spectra of the component elements of the TNB and COCR specimens, respectively, which were mirror-polished and exposed for 300 h. The Ti2p, Nb3d, Al2p, Co2p, Cr2p, Mo3d XPS spectra for mirror-polished specimens showed the largest peak assigned to metal oxides, respectively, and a small peak at low binding energy assigned to metals, respectively, indicating that passive film on the mirror-polished specimen was thin. On the other hand, the discolored specimens showed markedly smaller metal peaks in comparison with noise signals. The Ti2p spectra for TNB were similar to those for TCR and TI (data not shown), confirming the formation of a thin passive film on the discolored

specimens. Although the metal state in Al2p and Nb3d in the discolored TNB specimen could hardly be detected, that in the Co2p, Cr2p, and Mo3d spectra for the COCR specimen was clear. Therefore, the small signal of this metal peak may have been caused by protein adsorption and formation of a thick passive film.

DISCUSSION

Color differences were classified into six ranks: ΔE*ab=0–0.5, trace; ΔE*ab=0.5–1.5, slight; ΔE*ab=1.5–3.0, noticeable; ΔE*ab=3.0–6.0, appreciable; ΔE*ab=6.0–12.0, much; and ΔE*ab=12.0–, very much25). Difference in the degree of discoloration of specimens after exposure to the oral environment was large between individuals and between the exposure periods. The box plot of change in color is shown in Fig. 2. The median value of ΔE*ab in TI in this study was 3.5 after 300 h exposure to the oral environment, indicating appreciable

1064 Dent Mater J 2012; 31(6): 1060–1067

Page 7: Discoloration of Ti-20Cr alloy in oral environment Takemoto, S; …ir.tdc.ac.jp/irucaa/bitstream/10130/2994/1/31_2012-195.pdf · 2013-03-12 · Discoloration of Ti-20Cr alloy in oral

discoloration. The median value of ΔE*ab in TCR, TNB, and COCR was less than 1.5, indicating slight discoloration. No significant difference was observed in ΔE*ab value with length of exposure. Thus, change in color in TCR was equivalent to that in commercially available Ti or cobalt-chromium-molybdenum alloys. However, a few specimens of each type of alloy showed ΔE*ab value of over 6. The cause for this change, however, remains to be determined.

To evaluate the influence of the oral environment, including saliva, food, and drink, on corrosion resistance in Ti or Ti alloys, use of fluoride-contained toothpaste and peroxide-contained denture cleanser was excluded as much as possible in this study. Moreover, the specimens were mirror-polished and the volunteers all less than 35 years old. Maximum exposure was kept to 300 h. This meant that the saliva had high buffering capacity and that there was only a low risk of caries in the volunteers. Furthermore, the discoloration test was performed over a short period of time. If the patients, however, had worn the palatal plate for 10 h per day, this would correspond to one month of exposure. In spite of the test period, few of the Ti alloys showed discoloration.

Several studies have reported that discoloration of dental gold- or silver-based alloys in the oral environment was caused by corrosion products such as sulfide and oxide5,6,9,10). Endo et al. reported that corrosion products differed depending on the composition of the alloy: Au-based alloys had metal sulfide and silver-based alloy restorations had oxides of non-precious elements such as In2O3, ZnO, and SnO2

5,26). Komoriyama et al. investigated commercially pure Ti and silver-palladium-copper-gold alloy in dentures in the elderly over 6 months, and found that the surface of the alloys showed evidence of corrosion products such as sulfide10). Although silver-palladium-copper-gold alloy showed discoloration with exposure to vapor sulfur compounds, Ti or cobalt-chromium alloys did not9). Denture plates made from Ti-6Al-4V alloy showed discoloration after use for three years17). These studies indicate that discoloration of alloys in the oral environment differs depending on type of alloy, age of patient, and periods of use.

Generally, Ti and its alloys have good corrosion resistance and biocompatibility, with formation of thin passive films composed of calcium phosphate on the alloys. However, corrosion of these alloys has been observed with exposure to fluoride-containing prophylactic agents11,12,20), macrophage-generated peroxides14,16), or sulfide under specific conditions27). On soaking in denture cleanser, Ti alloy denture bases blacken, suggesting that alkaline and peroxides contained in these cleansers induce a change in color in Ti alloys15). Noguchi et al. suggested that Ti-20Cr alloy shows greater resistance to corrosion in fluoride- or peroxide-containing solutions among seven kinds of Ti alloy24). Takemoto et al. suggested that resistance to fluoride-induced corrosion is correlated with chromium-rich oxide film on titanium alloys22,23). One cause of discoloration of Ti alloys is the development of an oxide film28). Increase in the thickness of this film causes change in interaction with

light, resulting in change in color. This indicates that an increase in the thickness of the oxide film results in the generation of corrosion products and subsequent discoloration.

In this study, observation of the adhered thin film on the Ti alloys after exposure to the oral environment revealed no bacteria. The XPS analysis revealed that the outermost surface of the alloys consisted of carbon, oxygen, and nitrogen. Change in color (ΔE*ab) increased or decreased, regardless of length of exposure. Equilibrium of serum proteins such as albumin and fibrinogen in the human body is achieved by repeated cycles of adsorption and desorption29-31). A 0.2–0.5-µm layer of adhesive substances was observed on Ti surfaces after exposure to the oral environment10). In the present study, the volunteers consumed food and drink with the palatal plate in position during the experimental period. Consequently, residue from the food may have remained on the alloys. Therefore, biomolecules such as protein originating from saliva or food were adsorbed and desorbed on the Ti alloys, and aggregation of this material may have contributed to the formation of a thin film.

Koike and Fujii reported marked discoloration of Ti in formulaic acid solution and the formation of an oxide film32). Burstein et al. observed slight nucleation of pits on Ti exposed to saline solution containing serum proteins33). Our previous study suggested that adsorbed albumin film on Ti delayed fluoride-induced corrosion34,35). Thus, in rare cases, proteins or organic acid may either corrode or protect titanium alloys. In the present study, even where biomolecules had adsorbed to the Ti alloys, small metal peaks were observed, as shown in Fig. 4. In other words, exposure to the oral environment did not result in corrosion due to the production of corrosion products by bacteria or oxidation.

In an in vivo discoloration test, differences in change in color of three Ti alloys or cobalt-chromium-molybdenum alloys were not significant. Moreover, Ti-Cr alloys were shown to possess the mechanical properties required for use in prosthetic devices such as denture bases and fixed bridges36,37). This indicates that Ti-20Cr alloy could be applied to prosthetic devices such as denture bases, crowns, bridges, and dental implants.

CONCLUSIONS

To compare commercially available Ti and cobalt-chromium-molybdenum alloys, the resistance of Ti-20Cr alloy to discoloration and corrosion was investigated in an oral environment over a short period. The results revealed the following:

1. No significant difference was observed in change in color in Ti-20Cr, commercially pure Ti, Ti-6Al-7Nb, or Co-29Cr-5Mo alloy with exposure to an oral environment for 300 h.

2. The XPS analysis revealed carbon, oxygen, and nitrogen originating from saliva, food, and drink, regardless of type of alloy, in specimens showing discoloration. Although a thin film was

1065Dent Mater J 2012; 31(6): 1060–1067

Page 8: Discoloration of Ti-20Cr alloy in oral environment Takemoto, S; …ir.tdc.ac.jp/irucaa/bitstream/10130/2994/1/31_2012-195.pdf · 2013-03-12 · Discoloration of Ti-20Cr alloy in oral

observed on the specimens, there appeared to be no adhesive bacteria or corrosion.

3. The degree of discoloration in experimental Ti-20Cr alloy may be similar to that of other commercially available Ti and Co-29Cr-5Mo alloys.

ACKNOWLEDGMENTS

This study was supported by the following: a Research Promotion Grant from the Dean of Tokyo Dental College, a grant from the Science Research Promotion Fund from the Promotion and Mutual Aid Corporation for Private Schools of Japan, and a Grant-in Aid for Scientific Research from the Ministry of Education, Culture, Sports, Science and Technology, Japan. The authors would like to thank Mrs. Iwanuma E. of the Department of Removable Prosthodontics and Gerodontology at Tokyo Dental College, Mr. Tadokoro K. and Mrs. Watanabe E. of the Oral Health Science Center at Tokyo Dental College for their invaluable support. Finally, we would like to thank Associate Prof. Williams J. of Tokyo Dental College, for assistance with the English of this manuscript.

REFERENCES

1) Davis RR, Lockwood PE, Hobbs DT, Messer RLW, Price RJ, Lewis JB, Wataha JC. In vitro biological effects of sodium titanate materials. J Biomed Mater Res B: Appl Biomater 2007; 83: 505-511.

2) Wataha JC, Hobbs DT, Lockwood PE, Davis RR, Elvington MC, Lewis JB, Messer RLW. Peroxotitanates for biodelivery of metals. J Biomed Mater Res B: Appl Biomater 2009; 91: 489-496.

3) Yamamoto A, Honma R, Sumita M. Cytotoxicity evaluation of 43 metal salts using murine fibroblasts and osteoblastic cells. J Biomed Mater Res 1998; 39: 331-340.

4) Wataha JC. Biocompatibility of dental casting alloys: A review. J Prosthet Dent 2000; 83: 223-234.

5) Matsuda K, Endo K, Yamada K, Ohno H. In vivo corrosionand tarnish of dental Au-based and Ag-based alloy restorations. J Esthet Dent 1998; 11: 58-66.

6) Takayama Y, Miura E, Hosoi Y, Maeda N, Shibuya K, Ishikawa M. A clinical study on discoloration of 12 wt% Au-Ag-Pd alloy -Oral microbial flora and volatile sulfur compounds (VSC). J J Prosthodont Res 2000; 44: 208-220.

7) Sutton AJ, Rogers PM. Discoloration of a titanium alloy removable partial denture: A clinical report. J Prosthodont 2001; 10: 102-104.

8) Soma H, Imamura Y. The ciurcumstances of cast titanium prosthesis. Quintessence Dent Technol 2001; 26: 462-473.

9) Takayama Y, Miura E, Hosoi Y, Ishikawa M, Shibuya K. A study on discoloration of Au-Ag-Pd alloy -Part 1. Influence of oral microorganism. J J Prosthodont Soc 2002; 46: 223-232.

10) Komoriyama M, Takayama Y, Nomoto R, Miura E, Hosoi Y, Ishikawa M. Surface analysis of discolored dental alloys in the oral environment. J J Dental Mater Dev 2004; 23: 193-199.

11) Probster L, Lin W, Huttemann H. Effect of fluoride prophylactic agents on titanium surfaces. Int J Oral Maxilofac Implants 1992; 7: 390-394.

12) Toumelin-Chemla F, Rouelle F, Burdairon G. Corrosive properties of fluoride-containing odontologic gels against titanium. J Dent 1996; 24: 109-115.

13) Reclaru L, Meyer JM. Effects of fluorides on titanium and other dental alloys in dentistry. Biomaterials 1998; 19: 85-92.

14) Mu Y, Kobayashi T, Sumita M, Yamamoto A, Hanawa T. Metal ion release from titanium with active oxygen species generated by rat macrophages in vitro. J Biomed Mater Res 2000; 49: 238-243.

15) Abe T, Matsumoto M, Hattori M, Hasegawa K, Yoshinari M, Kawada E, Oda Y. Discoloration of titanium induced by denture cleaner. J J Dent Mater Dev 2001; 20: 366-371.

16) Mu Y, Kobayashi T, Tsuji K, Sumita M, Hanawa T. Causes of titanium release from plate and screws implanted in rabbits. J Mater Sci: Mater Med 2002; 13: 583-588.

17) Takayama Y, Takishin N, Tsuchida F, Hosoi T. Survey on use of titanium dentures in Tsurumi University Dental Hospital for 11 years. J Prosthod Res 2009; 53: 53-59.

18) Nakagawa M, Matsuya S, Shiraishi T, Ohta M. Effect of fluoride concentration and pH on corrosion behavior of titanium for dental use. J Dent Res 1999; 78: 1568-1572.

19) Nakagawa M, Matsuya S, Udoh K. Corrosion behavior of pure titanium and titanium alloys in fluoride-containing solutions. Dent Mater J 2001; 20: 305-314.

20) Schiff N, Grosgogeat B, Lissac M, Dalard F. Influence of fluoridated mouthwashes on corrosion resistance of orthodontics wires. Biomaterials 2004; 25: 4535-4542.

21) Nakagawa M, Matono Y, Matsuya S, Udoh K, Ishikawa K. The effect of Pt and Pd alloying additions on the corrosion behavior of titanium in fluoride-containing environments. Biomaterials 2005; 26: 2239-2246.

22) Takemoto S, Hattori M, Yoshinari M, Kawada E, Asami K, Oda Y. Corrosion behavior and surface characterization of Ti-20Cr alloy in a solution containing fluoride. Dent Mater J 2004; 23: 379-386.

23) Takemoto S, Hattori M, Yoshinari M, Kawada E, Asami K, Oda Y. Corrosion mechanism of Ti-Cr alloys in solution containing fluoride. Dent Mater 2009; 25: 467-472.

24) Noguchi T, Takemoto S, Hattori M, Yoshinari M, Kawada E, Oda Y. Discoloration and dissolution of titanium and titanium alloys with immersion in peroxide- or fluoride-containing solutions. Dent Mater J 2008; 27: 117-123.

25) Johnston WM, Kao EC. Assessment of appearance match by visual observation and clinical colorimetry. J Dent Res 1989; 68: 819-822.

26) Endo K, Ohno H, Matsuda K, Asakura S. Electrochemical and surface studies on the passivity of a dental Pd-based casting alloy in alkaline sulphide solution. Corro Sci 2003; 45: 1491-1504.

27) Yoshida T, Aoki H, Yoshida K, Irie N, Murayama D. Color and Weight changes of titanium and titanium alloys immersed in various solutions containing sodium sulfide. J J Dent Products 2009; 23: 10-19.

28) Sul YT, Johansson CB, Jeong Y, Albrektsson T. The electrochemical oxide growth behaviour on titanium in acid and alkaline electrolytes. Med Eng Phy 2001; 23: 329-346.

29) Williams DF, Askill IN, Smith R. Protein absorption and desorption phenomena on clean metal surfaces. J Biomed Mater Res 1985; 19: 313-320.

30) Williams RL, Williams DF. Albumin adsorption on metal surfaces. Biomaterials 1988; 9: 206-212.

31) Fukuzaki S, Urano H, Nagata K. Adsorption of bovine serum albumin onto metal oxide surfaces. J Ferment Bioeng 1996; 81: 163-167.

32) Koike M, Fujii H. The corrosion resistance of pure titanium in organic acids. Biomaterials 2001; 22: 2931-2936.

33) Burstein GT, Liu C. Nucleation of corrosion pits in Ringer’s solution containing bovine serum. Corros Sci 2007; 49: 4296-4306.

34) Takemoto S, Hattori M, Yoshinari M, Kawada E, Oda Y. Corrosion behavior and surface characterization of titanium

1066 Dent Mater J 2012; 31(6): 1060–1067

Page 9: Discoloration of Ti-20Cr alloy in oral environment Takemoto, S; …ir.tdc.ac.jp/irucaa/bitstream/10130/2994/1/31_2012-195.pdf · 2013-03-12 · Discoloration of Ti-20Cr alloy in oral

in solution containing fluoride and albumin. Biomaterials 2005; 26: 829-837.

35) Takemoto S, Hattori M, Yoshinari M, Kawada E, Oda Y. Suppression of fluoride-induced corrosion of titanium by albumin in oral modified environment. J Biomed Mater Res B Appl Biomater 2008; 87: 475-481.

36) Koike M, Itoh M, Okuno O, Kimura K, Takeda O, Okabe TH, Okabe T. Evaluation of Ti-Cr-Cu alloys for dental applications. J Mater Eng Perform 2005; 14: 778-783.

37) Hattori M, Takemoto S, Yoshinari M, Kawada E, Oda Y. Effect of chromium content on mechanical properties of casting Ti-Cr alloys. Dent Mater J 2010; 29: 570-578.

1067Dent Mater J 2012; 31(6): 1060–1067