38
4 5 6 7 ENERGY METERS POWER MONITORS ANALOGUE PANEL METERS DIGITAL PANEL METERS TRANSDUCERS AND RECORDERS TRANSFORMERS SHUNTS CONTROLLING AND RELAYS APPENDIX 3 2 1 ANALOGUE PANEL METERS Overview of product range 060 General overview Product selection guide 063 By functions by applications Info & advice 064 "Keeping up with current changes" NORMEUROPE range 066 Round barrel - for high-level operating restrictions LOGIC range 080 Square barrel - for standard applications COHO/LK range 094 Hour meters CVAi range 096 Switches 58 59

DIGITAL PANEL METERS 3 ANALOGUE · PDF fileANALOGUE PANEL METERS ... Wattmeter Varmeter Product selection guide 63 92 DC Ammeter 90 Synchronization ... of static electricity on the

Embed Size (px)

Citation preview

Page 1: DIGITAL PANEL METERS 3 ANALOGUE · PDF fileANALOGUE PANEL METERS ... Wattmeter Varmeter Product selection guide 63 92 DC Ammeter 90 Synchronization ... of static electricity on the

4

5

6

7

ENER

GY M

ETER

SPO

WER

MONITO

RSAN

ALOG

UEPA

NEL

METE

RSDIGITA

LPA

NEL

METE

RSTR

ANSD

UCER

SAN

D RE

CORD

ERS

TRAN

SFOR

MERS

SHUN

TSCO

NTRO

LLING

AND

RELA

YSAP

PEND

IX

3

2

1

ANALOGUEPANEL METERS

Overview of product range060 General overview

Product selection guide063 By functions by applications

Info & advice064 "Keeping up with current changes"

NORMEUROPE range066 Round barrel - for high-level operating restrictions

LOGIC range080 Square barrel - for standard applications

COHO/LK range094 Hour meters

CVAi range096 Switches

5859

Page 2: DIGITAL PANEL METERS 3 ANALOGUE · PDF fileANALOGUE PANEL METERS ... Wattmeter Varmeter Product selection guide 63 92 DC Ammeter 90 Synchronization ... of static electricity on the

Gene

ral o

vervi

ewAn

alogu

e pa

nel m

eters ANALOGUE PANEL METERS

66

The Normeuroperange

72

Maximum demandammeter

74

Phasemeter

75

Synchronizing meter

70

AC voltmeter

71

Frequency meters

76

DC ammeter

77

DC voltmeter

78

Command functionmeter

73

Wattmeter Varmeter

68

AC ammeter

NORMEUROPE range

Page 3: DIGITAL PANEL METERS 3 ANALOGUE · PDF fileANALOGUE PANEL METERS ... Wattmeter Varmeter Product selection guide 63 92 DC Ammeter 90 Synchronization ... of static electricity on the

6364

SELECTION GUIDE

INFO & ADVICE

6061

4

5

6

7

ENER

GY M

ETER

SPO

WER

MONITO

RSAN

ALOG

UEPA

NEL

METE

RSDIGITA

LPA

NEL

METE

RSTR

ANSD

UCER

SAN

D RE

CORD

ERS

TRAN

SFOR

MERS

SHUN

TSCO

NTRO

LLING

AND

RELA

YSAP

PEND

IX

3

2

1

86

Maximum demandammeter

CVAI rangeCOHO/LK range

LOGIC range

80

LOGIC range

84

AC Voltmeter

85

Frequency meter

94

COHO Hour meters

95

LK hour meters

96

Switches

(consult us)

Customized products

82

AC Ammeter

93

DC Voltmeter

87

WattmeterVarmeter

Product selectionguide

63

92

DC Ammeter

90

Synchronizationinstruments

88

Phasemeter

Page 4: DIGITAL PANEL METERS 3 ANALOGUE · PDF fileANALOGUE PANEL METERS ... Wattmeter Varmeter Product selection guide 63 92 DC Ammeter 90 Synchronization ... of static electricity on the

Prod

uct selec

tion

guide

Analo

gue

pane

l mete

rs

Page 5: DIGITAL PANEL METERS 3 ANALOGUE · PDF fileANALOGUE PANEL METERS ... Wattmeter Varmeter Product selection guide 63 92 DC Ammeter 90 Synchronization ... of static electricity on the

6064

GENERAL OVERVIEW

INFO & ADVICE

6263

4

5

6

7

ENER

GY M

ETER

SPO

WER

MONITO

RSAN

ALOG

UEPA

NEL

METE

RSDIGITA

LPA

NEL

METE

RSTR

ANSD

UCER

SAN

D RE

CORD

ERS

TRAN

SFOR

MERS

SHUN

TSCO

NTRO

LLING

AND

RELA

YSAP

PEND

IX

3

2

1

CHOOSING AN ANALOGUE PANEL METER

66

NORMEUROPE

94

COHO LK

80

LOGIC

LOGIC, the most extended rangeto meet all specific needs.

COHO, the industryreference for highlimit operating environments

and LK for standardapplications.

LK

COHO LK

1 x 9 blades

2 x 9 blades

1 x 9 blades

Front panel drilling

Round barrel

Square barrel

Rectangular barrel

Front panel

Format 48x48 72x72 96x96 144x144 48x48 48x48 48x48 72x72 96x96 144x144

Standard functions

AC Ammeter

AC Voltmeter

Pointer dial frequency meter

Vibrating reed frequency meter

Maximum demand ammeter

Wattmeter / Varmeter

Phasemeter

DC Ammeter

DC Voltmeter

Hour meter

Synchronisation apparatus

Synchronoscope

Double voltmeter

Differential voltmeter

Zero voltmeter

Phase rotation panel meter

Command functions meter

AC Current / AC Voltage

Frequency

DC Current / DC Voltage

Temperature

Advantages

Double vibrating reed frequency meter

NORMEUROPE, the industry reference for the production,transportation and distribution

of electrical energy for high-leveloperating constraints

2 x 13 blades

Page 6: DIGITAL PANEL METERS 3 ANALOGUE · PDF fileANALOGUE PANEL METERS ... Wattmeter Varmeter Product selection guide 63 92 DC Ammeter 90 Synchronization ... of static electricity on the

Info

& ad

viceAn

alogu

e pa

nel m

eters KEEPING UP WITH CURR

SELECTING A PANEL METER

The essential function of the analoguepanel meter is to display instantaneous and variable values.It shows the pointer's position and movement, both required for monitoring industrial processes.

Panel meters, though robust by nature, are nevertheless sensitive to degraded environments. It is therefore recommended to choosecustomized solutions for military applications, for on board railapplications or for explosive atmospheres.

Choose the instrument size depending on the distance between theoperator and the mounting panel.Choose the pointer deflection: a deflection of 240° may be preferredto the usual 90° deflection, to facilitate the reading of extended ranges.

As a panel meter is a low-cost item, it is easily installed at the various command and monitoring points: the switchboard panels of LV distribution networks, motor drive control units or automation device panels.

Choose the value to be displayed in order to monitor and control aknown risk. For an electrical line, for example, the voltage value isselected, important for ensuring user safety.

Functions

Ergonomics Options and accessories

It is important to take into account mechanical specifications, environ-mental restrictions, standards in force, consumption and compatibilitywith sensors, in order to choose the appropriate dial ranges and cali-bration scales.

Environmental and standardsrestrictions

MOVING IRON OR MOVING COIL?The electric current is read directly by a sensor guiding the pointer movement. The two most usual types are:

The moving iron panel meter is composed of afixed magnet and a mobile magnet, mutuallyrepellent and placed in the field of a coil poweredby the current to be measured. The moving ironpanel meter carries out measurements in true RMS.

Calibrated for alternating current, it can also measure values in directcurrent but with a diminished accuracy rating of about 3. The scalecan be normal, motor or expanded.

Moving ironThe moving coil panel meter is composed of a coiltraversed by the current to be measured whichpivots around a permanently fixed magnet. Due toits low consumption, the moving coil panel meter

is the ideal instrument for the measurement of low direct currentvalues. Its scale is linear.

Moving coil

For other values, electronic circuits are combined with measurement components to adapt them (for example to a frequency) or to calculate therequired value (for example a phase shift value). The usual accuracy rating is class 1.5, with an error margin of ± 1.5 % for the nominalcalibre graduations shown on the dial.

Page 7: DIGITAL PANEL METERS 3 ANALOGUE · PDF fileANALOGUE PANEL METERS ... Wattmeter Varmeter Product selection guide 63 92 DC Ammeter 90 Synchronization ... of static electricity on the

6063

GENERAL OVERVIEW

SELECTION GUIDE

6465

How to connect a panel meterThe analogue panel meter is easy tomount and connect. The dial containsan array of pictograms and terminalsindicating polarity markers. A user guideis supplied only for complex functions. The precautions to be taken concern:• the cross-section of connecting wires

and their lugs;• the mounting or replacement of dials

when they are interchangeable;• heat loss, if the panel meters are

enclosed in very small volumes.

Maintenance of your panel meterCheck regularly that the connection ter-minals of the panel meter are tightenedcorrectly when a strong current is passedthrough it.Clean regularly to avoid the accumulationof static electricity on the plastic trans-parent surface of the dial (cleaning withsoapy water is sufficient).

QUIZ3 questions to test your knowledge

FOCUS

The life cycle of a panel meter is:

less than five years

10 to 20 years

50 years

What is the format of panel meter mostsuitable for mounting on a consolepanel?

144 x 144 mm

36 x 36 mm

60 x 45 mm

What is the measuring component mostsuitable for a motor scale ammeter?

Moving iron 90°

Thermal 90°

Rectified moving coil 240°

Consult the answers on:www.enerdis.fr.

4

5

6

7

ENER

GY M

ETER

SPO

WER

MONITO

RSAN

ALOG

UEPA

NEL

METE

RSDIGITA

LPA

NEL

METE

RSTR

ANSD

UCER

SAN

D RE

CORD

ERS

TRAN

SFOR

MERS

SHUN

TSCO

NTRO

LLING

AND

RELA

YSAP

PEND

IX

3

2

1

ENT CHANGES

ROUND BARREL OR SQUARE BARREL?

The external dimensions, mounting included, do not exceed a strictly standard format. The panel meters are therefore easily interchangeable and may be joined

together (for square grid format: see photo opposite).

Square barrel

Round barrel

SPECIAL FUNCTIONS

The maximum demand ammeter or thermal ammeter indicates the current RMS for a given period. It is designed to control slow overloads on transformers, cables, etc.

Necessary for the paralleling of generators or network-network or network-alternator coupling. The usercan thus ensure that the voltage to be synchronized and the reference voltage are of the same frequencyand amplitude and are in phase before carrying out the coupling.

The synchronoscope, used to synchronize 2 different sources, indicates the moment when their phaseshifting and frequencies are identical. The pointer indicates the central position and remains stationary.

The vibrating-reed dual frequency meter enables you to synchronize the frequency of asource with a reference source.

The double voltmeter, composed of two independent moving iron measuring elements, is used tosynchronize the voltages of two different sources, and indicates the voltage present on each.

The differential or zero voltmeter is powered by the voltages of two different sources andindicates the percentage of difference existing between the source to be synchronized and the nominalvoltage.

The phase rotation sequence indicator enables you to verify that thephase rotation sequence of a three-phase system is respected.

Synchronizing instruments

Maximum demand ammeters

Synchronoscope in theNORMEUROPE range

Maximum demandammeter in the

LOGIC range

Because they are easier to manufacture, round barrel panel meters have a lowerunit cost. However, there is no standard width for barrels.

Page 8: DIGITAL PANEL METERS 3 ANALOGUE · PDF fileANALOGUE PANEL METERS ... Wattmeter Varmeter Product selection guide 63 92 DC Ammeter 90 Synchronization ... of static electricity on the

NORM

EURO

PE ran

geAn

alogu

e pa

nel m

eters NORMEUROPE RANGE

Round barrel analogue panel meters for high-level operating constraints

Accurate

Slim-line, smallbarrel diameter,multiple connec-tion possibilities.

Attractive designand easy to read.

68

AC ammeter

70

AC voltmeter

PRODUCT ADVANTAGES WIDE CLIENT REFERENCE BASE: main utilities, marine applications, ener-

gy producers and distributors.

WIDE CHOICE of functions, formats, ratings and options.

LONG PRODUCT LIFE CYCLE

71

Frequency meter

Standard: IEC 60051-1Accuracy: class 1.5 (± 1.5% error margin at full scale)Front panel protection: IEC 60529(see presentation table)Dielectric test voltage:IEC 144-2 kV - 50 Hz - 1 mmMaximum service voltage: 650 VacResistance to shock:IEC 68-2-27Resistance to vibration:IEC 60068-2-6Environment: IEC 68-1Reference temperature: 23 °C ± 2 °COperating temperature: -25 °C to +50 °CStorage temperature: -25 °C to +70 °CRelative humidity: < 90 % to 40 %Mounting:• Front panel mounting• Panel thickness: 8 mm max.

Casing materials:Barrel: self-extinguishing polycarbonateFront panel: polymethyl methacrylate(glass option NEL)Additional terminal: socket in Bakelite,cover in ABSDial: light alloy, black markers on whitebackgroundBlack knife-edge arrow pointerOperating position:calibrated for vertical position (± 10 %)Overloads:Voltmeter and frequency meter- 1.2 Un permanent- 2 Un during 5 secsAmmeter- 1.3 In permanent- 10 In during 5 secsExtreme values:Safety recommendation IEC 60 051-11-1.2 - 1.5 - 2 - 2.5 - 3 - 4 - 5 - 6 - 7.5 - 8- 9 and their multiples and decimal sub-multiples

General specifications:

74

Phasemeter

72

Maximum demand ammeter

73

Wattmeter Varmeter

75

Synchronizing meter

76

DC ammeter

78

Command function meter

77

DC voltmeter

Page 9: DIGITAL PANEL METERS 3 ANALOGUE · PDF fileANALOGUE PANEL METERS ... Wattmeter Varmeter Product selection guide 63 92 DC Ammeter 90 Synchronization ... of static electricity on the

4

5

6

7

ENER

GY M

ETER

SPO

WER

MONITO

RSAN

ALOG

UEPA

NEL

METE

RSDIGITA

LPA

NEL

METE

RSTR

ANSD

UCER

SAN

D RE

CORD

ERS

TRAN

SFOR

MERS

SHUN

TSCO

NTRO

LLING

AND

RELA

YSAP

PEND

IX

3

2

1

Dimensions and panel drilling specifications

Mechanical specifications

Accessories

DeflectionFormat 48x48 72x72 96x96 144x144 48x48 72x72 96x96 144x144Front panel sealed gasket 2465 001 2314 375 2314 376 2465 004 2465 001 2314 375 2314 376 2465 004Fitting clip (without seal) 2328 558 2302 348 2307 086 2328 558 2302 348 2307 086Standard dial

Customized dial

Antistatic liquid 9030 00676Insulation sleeve for terminals ACCQ 1001

6667

DeflectionFormat 48x48 72x72 96x96 144x144 48x48 72x72 96x96 144x144Panel mounting and tightnessProtection: front panel IP 40; unit IP 20 2 studs M2.5 2 studs M4 2 studs M4 2 studs M5 2 studs M2,5 2 studs M4 2 studs M4 2 studs M5360° panel meters all with 4 studsOption Ring fastener IP 40 front panel 48 mm drill 58 mm drill 88 mm drill 48 mm drill 58 mm drill 88 mm drillOption Sealed gasket IP 52 front panel 2 studs M2.5 2 studs M4 2 studs M4 2 studs M5 2 studs M2.5 2 studs M4 2 studs M4 2 studs M5Option Reinforced mounting+ gasket IP 52 front panel 4 studs M2.5 4 studs M4 4 studs M4 4 studs M5 4 studs M2.5 4 studs M4 4 studs M4 4 studs M5Option Watertight (except Imax) IP 54 front panel 4 studs M4 4 studs M4 4 studs M5 4 studs M2.5 4 studs M4 4 studs M4 4 studs M5Option Marine (except Imax) IP 55 full unit 4 studs M4 4 studs M4 4 studs M5 4 studs M2.5 4 studs M4 4 studs M4 4 studs M5Front cover (non standard)NEL (in glass with black surround)

NEL non-reflecting glass (matt surface with black surround)

Dial non-standard optionsCreation of dial markings (where feasible)

Colour marking

Colour zone

Black background, white markings

Markings not in standard documentation

Double scale

29 if 20 A max, 39 if 25 A max or more

A x A Panel meter Additional unitFormat 48x48 72x72 96x96 144x144 A BB (mm) 8 13 14 20C (mm) diam. 44 diam. 55 diam. 80 diam. 80D 90° deflection (mm) 46 24.5D 250° deflection or blades (mm) 58 71 71 66

D 360° deflection (mm) 128 phasem. 131 phasem.108 synchro 104 synchro

D command unit (mm) 93Ø (mm) 45 58 88 138l (mm) 20.25 26.5 34 55e or p (mm) 3.5 4.5 4.5 5.5 48 122weight (kg) 0.20 0.25 0.30 0.45 0.30 0.70terminal M4 and Faston up to 20 A, M6 for higher values cage for 4 mm2 wire

SELECTION GUIDEINFO & ADVICE

RANGE INFORANGE CONTD.

63646668

Page 10: DIGITAL PANEL METERS 3 ANALOGUE · PDF fileANALOGUE PANEL METERS ... Wattmeter Varmeter Product selection guide 63 92 DC Ammeter 90 Synchronization ... of static electricity on the

Instruments Deflection/Motor Format Scale Rating Frequencyscale CT ratio

Complete Ind 90° ferro 72x72 0-15/90 A direct 15 A 50 Hz250° magneto 144x144 0-1.25/2.5 kA CT 1250/5 A 60 Hz

NORM

EURO

PE ran

geAn

alogu

e pa

nel m

eters NORMEUROPE RANGE

DeflectionStandard scale modelAccuracy class: 1.5Measuring component: moving iron50-60-400 Hz and rectified moving coil50-10,000 HzPseudo linear scale (moving iron)Interchangeable dial, except 144x144 Consumption: 1 VAMotor scale modelAccuracy class: 1.5Measuring component: moving iron 50-60-400 HzPseudo linear scaleCalibrated 0-In up to 2/3 of deflection, beyond overload zone Interchangeable 90° dial, except144x144 formatConsumption: 1 VA

DeflectionStandard scale modelAccuracy class: 1.5Measuring component: rectified moving coil 50-10,000 HzLinear scale With additional unit "A" in48x48 format Consumption: 0.5 VAMotor scale modelAccuracy class: 1.5Measuring component: rectified moving coil 50-10,000 HzLinear scale Calibrated 0-In up to 2/3 of deflection, beyond overload zone With additional unit "A" in48x48 format

Consumption: 0.5 VA

ACAmmeter

T O O R D E R

Direct connection

Feasibility limits DeflectionFormat 48x48 72x72 96x96 144x144 48x48 72x72 96x96 144x144Direct connection

Standard moving iron 0.5 to 15 A 0.5 to 50 Ascale moving coil 1 mA to 25 A 1 mA to 25 A

Motor moving iron 2 to 6 In 0.5 to 12 A 0.5 to 40 Ascale moving coil 2/3/5 In 0.5 to 20 A

Connection on CT

Standard moving iron 1 to 6.6 Ascale moving coil 1.3 to 6.6 A 1.2 to 6.6 A

Motor moving iron 2 to 6 In 1 A and 5 Ascale moving coil 2/3/5 In 1 A and 5 A

Deflection Moving iron. 50 Hz Format 48x48 72x72 96x96 144x144 48x48 72x72 96x96 144x144Rating Scale In5 A 0-5 A A90A 0302 A90A 0502

10 A 0-10 A A90A 0303 A90A 0503

20 A 0-20 A A90A 0304 A90A 0504

30 A 0-30 A A90A 0305 A90A 0505

50 A 0-50 A A90A 0307 A90A 0507

Rating Scale 3 In5 A 0-5/15 A A90A 0533

10 A 0-10/30 A A90A 0534

20 A 0-20/60 A A90A 0535

30 A 0-30/90 A A90A 0536

40 A 0-40/120 A A90A 0537

Rating Scale 5 In5 A 0-5/25 A

E.g.

Customized products

Page 11: DIGITAL PANEL METERS 3 ANALOGUE · PDF fileANALOGUE PANEL METERS ... Wattmeter Varmeter Product selection guide 63 92 DC Ammeter 90 Synchronization ... of static electricity on the

4

5

6

7

ENER

GY M

ETER

SPO

WER

MONITO

RSAN

ALOG

UEPA

NEL

METE

RSDIGITA

LPA

NEL

METE

RSTR

ANSD

UCER

SAN

D RE

CORD

ERS

TRAN

SFOR

MERS

SHUN

TSCO

NTRO

LLING

AND

RELA

YSAP

PEND

IX

3

2

1

6869

96

Ammeter switch

67

Accessories

177

CT Current transformers Associated products

Format 48x48 72x72 96x96 48x48 72x72 96x96 144x144 48x48 72x72 96x96 144x144Deflection Moving iron 50 Hz Moving iron 50 Hz

Panel meter and dial separate Complete panel meter Complete panel meterRatio Scale Complete panel meter

A90A 0487 A90A 0486 A90A 0485CT 1.3 In Dial only5/5 A 0-6.5 A CADR 0136 CADR 0702 CADR 0492 10/5 A 0-13 A CADR 0137 CADR 0703 CADR 0493 15/5 A 0-20 A CADR 0138 CADR 0704 CADR 0494 20/5 A 0-26 A CADR 0111 CADR 0461 CADR 0441 A90A 0211 A90A 0311 A90A 0511 A250 A0611 25/5 A 0-32.5 A CADR 0110 CADR 0701 CADR 0486 30/5 A 0-40 A CADR 0112 CADR 0462 CADR 0442 A90A 0212 A90A 0312 A90A 0512 A250 A0612 40/5 A 0-52 A CADR 0113 CADR 0463 CADR 0443 A90A 0213 A90A 0313 A90A 0513 A250 A0613 50/5 A 0-65 A CADR 0114 CADR 0464 CADR 0444 A90A 0214 A90A 0314 A90A 0514 A250 A0614 60/5 A 0-80 A CADR 0115 CADR 0465 CADR 0445 A90A 0215 A90A 0315 A90A 0515 A250 A0615 75/5 A 0-100 A CADR 0116 CADR 0466 CADR 0446 A90A 0216 A90A 0316 A90A 0516 A250 A0616 100/5 A 0-130 A CADR 0117 CADR 0467 CADR 0447 A90A 0217 A90A 0317 A90A 0517 A250 A0617 125/5 A 0-165 A CADR 0118 CADR 0468 CADR 0448 A90A 0218 A90A 0318 A90A 0518 A250 A0618 150/5 A 0-200 A CADR 0119 CADR 0469 CADR 0449 A90A 0219 A90A 0319 A90A 0519 A250 A0619 200/5 A 0-260 A CADR 0120 CADR 0470 CADR 0450 A90A 0220 A90A 0320 A90A 0520 A250 A0620 250/5 A 0-325 A CADR 0121 CADR 0471 CADR 0451 A90A 0221 A90A 0321 A90A 0521 A250 A0621 300/5 A 0-400 A CADR 0122 CADR 0472 CADR 0452 A90A 0222 A90A 0322 A90A 0522 A250 A0622 400/5 A 0-520 A CADR 0123 CADR 0473 CADR 0453 A90A 0223 A90A 0323 A90A 0523 A250 A0623 500/5 A 0-650 A CADR 0124 CADR 0474 CADR 0454 A90A 0224 A90A 0324 A90A 0524 A250 A0624 600/5 A 0-800 A CADR 0125 CADR 0475 CADR 0455 A90A 0225 A90A 0325 A90A 0525 A250 A0625 750/5 A 0-1 kA CADR 0126 CADR 0476 CADR 0456 A90A 0226 A90A 0326 A90A 0526 A250 A0626 800/5 A 0-1.04 kA CADR 0135 CADR 0481 CADR 0487 1000/5 A 0-1.3 kA CADR 0127 CADR 0477 CADR 0457 A90A 0227 A90A 0327 A90A 0527 A250 A0627 1250/5 A 0-1.65 kA CADR 0128 CADR 0478 CADR 0458 A90A 0228 A90A 0328 A90A 0528 A250 A0628 1500/5 A 0-2 kA CADR 0129 CADR 0479 CADR 0459 A90A 0229 A90A 0329 A90A 0529 A250 A0629 2000/5 A 0-2.6 kA CADR 0130 CADR 0480 CADR 0460 A90A 0230 A90A 0330 A90A 0530 A250 A0630 2500/5 A 0-3.25 kA CADR 0131 CADR 0482 CADR 0488 A90A 0331 A90A 0531 3000/5 A 0-4 kA CADR 0132 CADR 0483 CADR 0489 A90A 0332 A90A 0532 4000/5 A 0-5.2 kA CADR 0133 CADR 0484 CADR 0490 5000/5 A 0-6.5 kA CADR 0134 CADR 0485 CADR 0491 Ratio Scale Meter only

A90A 0107 A90A 0106 A90A 0105CT 3 In Dial only5/5 A 0-5/15 A CADR 0139 CADR 0169 CADR 0059 A90A 0239 A90A 0339 A90A 0539 A250 A0639 10/5 A 0-10/30 A CADR 0140 CADR 0170 CADR 0060 A90A 0240 A90A 0340 A90A 0540 A250 A0640 15/5 A 0-15/45 A CADR 0141 CADR 0171 CADR 0061 A90A 0241 A90A 0341 A90A 0541 A250 A0641 20/5 A 0-20/60 A CADR 0142 CADR 0172 CADR 0062 A90A 0242 A90A 0342 A90A 0542 A250 A0642 25/5 A 0-25/75 A CADR 0167 CADR 0168 CADR 0087 30/5 A 0-30/90 A CADR 0143 CADR 0173 CADR 0063 A90A 0243 A90A 0343 A90A 0543 A250 A0643 40/5 A 0-40/120 A CADR 0144 CADR 0174 CADR 0064 A90A 0244 A90A 0344 A90A 0544 A250 A0644 50/5 A 0-50/150 A CADR 0145 CADR 0175 CADR 0065 A90A 0245 A90A 0345 A90A 0545 A250 A0645 60/5 A 0-60/180 A CADR 0146 CADR 0176 CADR 0066 A90A 0246 A90A 0346 A90A 0546 A250 A0646 75/5 A 0-75/225 A CADR 0147 CADR 0177 CADR 0067 A90A 0247 A90A 0347 A90A 0547 A250 A0647 100/5 A 0-100/300 A CADR 0148 CADR 0178 CADR 0068 A90A 0248 A90A 0348 A90A 0548 A250 A0648 125/5 A 0-125/375 A CADR 0149 CADR 0179 CADR 0069 A90A 0249 A90A 0349 A90A 0549 A250 A0649 150/5 A 0-150/450 A CADR 0150 CADR 0180 CADR 0070 A90A 0250 A90A 0350 A90A 0550 A250 A0650 200/5 A 0-200/600 A CADR 0151 CADR 0181 CADR 0071 A90A 0251 A90A 0351 A90A 0551 A250 A0651 250/5 A 0-250/750 A CADR 0152 CADR 0182 CADR 0072 A90A 0252 A90A 0352 A90A 0552 A250 A0652 300/5 A 0-300/900 A CADR 0153 CADR 0183 CADR 0073 A90A 0253 A90A 0353 A90A 0553 A250 A0653 400/5 A 0-0.4/1.2 kA CADR 0154 CADR 0184 CADR 0074 A90A 0254 A90A 0354 A90A 0554 A250 A0654 500/5 A 0-0.5/1.5 kA CADR 0155 CADR 0185 CADR 0075 A90A 0255 A90A 0355 A90A 0555 A250 A0655 600/5 A 0-0.6/1.8 kA CADR 0156 CADR 0186 CADR 0076 A90A 0356 A90A 0556 750/5 A 0-0.75/2.25 kA CADR 0157 CADR 0187 CADR 0077 A90A 0357 A90A 0557 800/5 A 0-0.80/2.4 kA CADR 0158 CADR 0188 CADR 0078 1000/5 A 0-1/3 kA CADR 0159 CADR 0189 CADR 0079 1200/5 A 0-1.2/3.6 kA CADR 0160 CADR 0190 CADR 0080 1500/5 A 0-1.5/4.5 kA CADR 0161 CADR 0191 CADR 0081 2000/5 A 0-2/6 kA CADR 0162 CADR 0192 CADR 0082 2500/5 A 0-2.5/7.5 kA CADR 0163 CADR 0193 CADR 0083 3000/5 A 0-3/9 kA CADR 0164 CADR 0194 CADR 0084 4000/5 A 0-4/12 kA CADR 0165 CADR 0195 CADR 0085 5000/5 A 0-5/15 kA CADR 0166 CADR 0196 CADR 0086

Connection on CT 5 A

SELECTION GUIDEINFO & ADVICE

RANGE INFORANGE CONTD.

63646670

Page 12: DIGITAL PANEL METERS 3 ANALOGUE · PDF fileANALOGUE PANEL METERS ... Wattmeter Varmeter Product selection guide 63 92 DC Ammeter 90 Synchronization ... of static electricity on the

Customized productsConnection Deflection / Measure Format Scale Rating/ VT ratio Frequency

E.g. direct 90° moving iron 72x72 Vn 15 V 50 Hzon VT 250° moving coil 96x96 1.2 Vn 20 / 0.11 kV 60 Hz

NORM

EURO

PE ran

geAn

alogu

e pa

nel m

eters NORMEUROPE RANGE

DeflectionStandard scale modelAccuracy class: 1.5Measuring component: moving iron50-60-400 Hz and rectified moving coil50-10,000 HzPseudo linear scale (ferro)Interchangeable dial, except 144x144 Consumption: 4.5 VA maxExtended scale modelAccuracy class: 1.5Measuring component: moving iron 50-60-400 HzPseudo linear scaleConsumption: 2.5 VAWith additional "A" unit for 48x48 format in 250° and 90° if value < 100 V

DeflectionStandard scale modelAccuracy class: 1.5Measuring component: rectified moving coil 50-10,000 HzLinear scale Impedance 1 kΩ / VExtended scale modelAccuracy class: 1.5Measuring component: rectified moving coil 50-10,000 HzLinear scale Impedance 2 kΩ / VWith additional "A" unit in 48x48 format in 250° and 90° if value < 100 V

Deflection Ferro. 50 Hz Format 48x48 72x72 96x96 144x144 48x48 72x72 96x96 144x144Rating Scale Vn15 V 0-15 V

30 V 0-30 V

60 V 0-60 V

150 V 0-150 V

250 V 0-250 V A90V 0266 A90V 0366 A90V 0566 A250 0666

300 V 0-300 V A90V 0268 A90V 0368 A90V 0568 A250 0668

500 V 0-500 V A90V 0267 A90V 0367 A90V 0567 A250 0667

Rating Extended scale230 V 150-260 A90V 0588

400 V 300-450 A90V 0589

Deflection Ferro. 50 Hz Format 48x48 72x72 96x96 144x144 48x48 72x72 96x96 144x144VT ratio ScaleVT/100 V 0-1.2 Vn

VT/100/√3 V 0-1.2 Vn

96

Voltmeter switch

67

Accessories Associated products

T O O R D E R

Direct connection

Connection on VT

Feasibility limits

AC Voltmeter

DeflectionFormat 48x48 72x72 96x96 144x144 48x48 72x72 96x96 144x144Direct connectionScale Moving iron 15 to 600 VVn : 1.2 Vn Moving coil 1.5 to 600 V 3 to 600 V

Extended scale 10-15, 20-30, 40-70, 75-120, 80-120, 40-70, 80-120, 96-144,90-130, 90-140, 100-150, 200-300, 400-600 V 100-150, 400-600 V

Connection on VT Scale according to client specifications from Un/ 100/√3 V from Un/ 100/√3 V

Page 13: DIGITAL PANEL METERS 3 ANALOGUE · PDF fileANALOGUE PANEL METERS ... Wattmeter Varmeter Product selection guide 63 92 DC Ammeter 90 Synchronization ... of static electricity on the

4

5

6

7

ENER

GY M

ETER

SPO

WER

MONITO

RSAN

ALOG

UEPA

NEL

METE

RSDIGITA

LPA

NEL

METE

RSTR

ANSD

UCER

SAN

D RE

CORD

ERS

TRAN

SFOR

MERS

SHUN

TSCO

NTRO

LLING

AND

RELA

YSAP

PEND

IX

3

2

1

Format Voltage Measurement range

E.g. 72x72 100 V 58-62 Hz96x96 440 V 48-52 Hz

Pointer frequency meter DeflectionAccuracy class: 0.5 de FnMeasuring component: moving coil and frequency converterLinear scaleDomain of use: 0.80 Un to 1.15 UnWith additional "A" unit for 48x48 format in 250° and 90° if value < 100 VConsumption: 3 VA

Feasibility constraintsVoltage 57.7 V to 440 V and frequency 50 to 400 Hz

Vibrating-reed frequency meter Accuracy class: 0.5Measuring component: vibrating reed in field of coilAmplitude of vibration proportional to V2

Domain of use: 0.80 Un to 1.15 UnConsumption: 1.5 VA

Feasibility constraintsVoltage 57.7 V to 440 V

Deflection Format Voltage Measurement range

E.g. 90° 72x72 100 V 45-55 Hz250° 144x144 110 V 45-65 Hz

67

Accessories Associated products

Format 72x72 96x96 144x144Nominal Measurementvoltage range

100 V 45-55 Hz

55-65 Hz

230 V 45-55 Hz FA90 0681

55-65 Hz

400 V 45-55 Hz FA90 0682

55-.65 Hz

Format 72x72 96x96 144x144Nominal Measurementvoltage range 9 reed segments

100 V 48-52 Hz FL12 0373 FL12 0580

58-62 Hz

230 V 48-52 Hz FL12 0375 FL12 0582

58-62 Hz

400 V 48-52 Hz FL12 0376 FL12 0583

58-62 Hz

T O O R D E R

Format 72x72 96x96 144x144Nominal Measurementvoltage range

100 V 45-55 Hz

55-65 Hz

230 V 45-55 Hz

55-65 Hz

400 V 45-55 Hz

55-65 Hz

Deflection

Deflection

Frequency meter

7071

Customized products Customized products

SELECTION GUIDEINFO & ADVICE

RANGE INFORANGE CONTD.

63646672

Page 14: DIGITAL PANEL METERS 3 ANALOGUE · PDF fileANALOGUE PANEL METERS ... Wattmeter Varmeter Product selection guide 63 92 DC Ammeter 90 Synchronization ... of static electricity on the

Format Model Integration time Primary CT Hour meter supply

E.g. 72 x 72 101 B 15’ 100 / 5A96 X 96 161 B 8’ 600 / 5A 100V - 60 Hz

NORM

EURO

PE ran

geAn

alogu

e pa

nel m

eters

177

CT Current transformers

67

Accessories

Connection on CT

T O O R D E R

Deflection Accuracy class: 3Measuring component: spiralled double reed (I rms avg.) Frequency: 0-400 HzOverload capacity:1.5 In permanent10 In for 1 sConsumption: 3 VAPointer guided by measurement component and adjustable by button on front panel

Feasibility limitsHour meter power supply from 24 V to 440 V in 50 or 60 Hz for model 161B.

NORMEUROPE RANGE Maximum demandammeter

Associated products

Customized products

Integration DeflectionModel (I max)time

Calibre Graduation72x72 96x96

101B 8 min

15 min

131B With relay, breaking capacity 8 min

10 VA resistive, 250 Vac max or 0.5 A 15 min

161B With hour meter 8 min

230 V - 50 Hz, 99,999.99 h 15 min

7.5 Aaccording to primary CT / 5 A

Parameters to be indicated when ordering

Page 15: DIGITAL PANEL METERS 3 ANALOGUE · PDF fileANALOGUE PANEL METERS ... Wattmeter Varmeter Product selection guide 63 92 DC Ammeter 90 Synchronization ... of static electricity on the

4

5

6

7

ENER

GY M

ETER

SPO

WER

MONITO

RSAN

ALOG

UEPA

NEL

METE

RSDIGITA

LPA

NEL

METE

RSTR

ANSD

UCER

SAN

D RE

CORD

ERS

TRAN

SFOR

MERS

SHUN

TSCO

NTRO

LLING

AND

RELA

YSAP

PEND

IX

3

2

1

DeflectionLinear scale, measurement range according to client specifications (absorbed or generated power)Measuring component:moving coil 2 mA and electrical circuitin additional "B" unit.Accuracy class: 1.5Consumption:Circuit current 0.3 VA at InCircuit voltage 2.5 VA at Un

Overload capacity:Circuit current1.5 In permanent10 In for 5 s30 In for 3 sCircuit voltage1.3 permanent2 Un for 10 sDomain of use:between 0.8 and 1.3 SnVoltage 0.8 to 1.15 UnCurrent 0 to 1.2 InFrequency ± 5 Hz

Voltage or Scale Scalenetwork deflection Format Frequency CT ratio Direct / VT VT ratio beginning ending

E.g. Active single 90° 72 x 72 50 Hz 1000 / 5 A Direct 230 V 0 kW 250 kWReactive balanced 250° 96 x 96 60 Hz 400 / 5 A VT 20 Kv / 115 V - 12 Mvar + 12 Mvarthree-phase 3 wires

Network Frequency Current Voltage Deflection Deflection72x72 96x96 144x144 72x72 96x96 144x144

Single phase activeBalanced three- active direct 230 Vphase 3 wires reactive or 400 VBalanced three- active 50 Hz or on CT 1A

phase 4 wires reactive 60 Hz or or CT 5A on VTUnbalanced three active 400 Hz 100/√3-phase 3 wires reactive 110/√3 100Unbalanced three active 110 - 230 or-phase 4 wires reactive 400 V

T O O R D E R

177

CT Current transformers

67

Accessories

Associated products

WattmeterVarmeter

7273

Feasibility limitsVoltage 57.7 to 440 V

Customized products

Parameters to be indicated when ordering

SELECTION GUIDEINFO & ADVICE

RANGE INFORANGE CONTD.

63646674

Connection

Page 16: DIGITAL PANEL METERS 3 ANALOGUE · PDF fileANALOGUE PANEL METERS ... Wattmeter Varmeter Product selection guide 63 92 DC Ammeter 90 Synchronization ... of static electricity on the

Customized products

NORM

EURO

PE ran

geAn

alogu

e pa

nel m

eters

177

CT Current transformers

MeasurementNetwork Deviation Format Frequency Secondary CT Voltage range

E.g. SINGLE 250° 72 x 72 50 Hz 5 A 230 V 0.5 lead /1/0.5 lagUnbalanced 360° 144 x 144 60 Hz 1 A 440 V -1 / 0 / +1three-phase

Deflection Scale in cos ϕMeasuring component:Moving coil and electronic circuit inadditional "B" unit.Accuracy class: 2.5Consumption:Circuit current 0.3 VA Circuit voltage 0.2 VA Overload capacity:Circuit current 2 In permanent

10 In for 5 sCircuit voltage 1.3 Un permanent

2 Un for 10 sOperating range:Voltage 0.8 to 1.2 UnCurrent 0.2 to 1.2 InFrequency ± 5 Hz

DeflectionScale 4 quadrants in cos ϕAdditional "B" unitAccuracy class: 1.5Consumption:Circuit current 0.5 VACircuit voltage 10 VAOverload capacity:Circuit current 1.2 In permanent

10 In for 5 sCircuit voltage 1.2 Un permanent

2 Un for 5 sOperating range:Voltage 0.8 to 1.2 UnCurrent 0.2 to 1.2 InFrequency ± 5 Hz

NORMEUROPE RANGE Phasemeter

67

Accessories

Associated products

T O O R D E R

Block diagram

Frequency Secondary CT Voltage Measurement Deflection Deflection Deflectionrange 72x72 96x96 144x144 72x72 96x96 144x144 96x96 144x144

100 V 110 V 230 V 400 V

0.5 lead/1/0.2 lag0.5 lead/1/0.5 lag

-1 / 0 / +1

50 Hzor 60 Hz

Network

Unbalanced3-phase 3/4 wire

Single orbalanced3-phase 3/4 wires 1 A or 5 A

Parameters to indicate when ordering

Feasibility limitsVoltage 57.7 to 440 V, other measurement ranges

Page 17: DIGITAL PANEL METERS 3 ANALOGUE · PDF fileANALOGUE PANEL METERS ... Wattmeter Varmeter Product selection guide 63 92 DC Ammeter 90 Synchronization ... of static electricity on the

4

5

6

7

ENER

GY M

ETER

SPO

WER

MONITO

RSAN

ALOG

UEPA

NEL

METE

RSDIGITA

LPA

NEL

METE

RSTR

ANSD

UCER

SAN

D RE

CORD

ERS

TRAN

SFOR

MERS

SHUN

TSCO

NTRO

LLING

AND

RELA

YSAP

PEND

IX

3

2

1

DeflectionFormat 72x72 96x96 144x144Voltage Un100/√3 V 100 V BASS 0591 230 V BASS 0592 400 V BASS 0593

DeflectionFormat 96x96 144x144Frequency Voltage

50 Hz

100/√3 V 100 V SYNC 0686 230 V SYNC 0687 400 V

60 Hz

100/√3 V 100 V 230 V 400 V

Phase lamp 2318635001 2318635001

67

Accessories

Associated products

DeflectionAccuracy class: 1.5Three-phase network:2-wire connectionConsumption:Circuit reference 1.5 VA Circuit generator 5 VA Operating range: 0.8 to 1.2 VnOverload capacity:1.2 Vn permanent 2 Vn for 5 sAdditional unit "B"

Accuracy class: 0.5Consumption: 3 VAOperating range:0.8 to 1.15 UnMeasuring component: vibratingreed in field of coilAmplitude of vibration:proportional to V2

DeflectionAccuracy class: 2.5Consumption: 0.5 VA per circuitFrequency: 50-60 HzMeasurement range0.75 to 1.25 UnAdditional unit "B"

Synchronoscope Vibrating-reed double frequency

meter

DifferentialVoltmeter

DeflectionFormat 72x72 96x96 144x144Voltage Un100/√3 V 100 V C250 0691 230 V 400 V

Phase Format Frequency Voltage lamp

E.g. 144 x 144 50 Hz 100 V With96 x 96 60 Hz 440 Without

Format Frequency Voltage

E.g. 96 x 96 48-52 Hz 100/ √3V72 x 72 58-62 Hz 415V

T O O R D E R

Synchronizers

7475

2 rows of 9 segmentsFormat 72x72 96x96 144x144Frequency Voltage

48-52 Hz

100/√3 V 100 V FL12 0677 230 V FL12 0678 400 V FL12 0679

58-62 Hz

100/√3 V 100 V 230 V 400 V

Feasibility limitsVoltage 57.7 V to 440 V

Feasibility limitsVoltage 57.7 V to 440 V

Feasibility limitsMeasurement range, other...Voltage 57.7 V to 440 V

SELECTION GUIDEINFO & ADVICE

RANGE INFORANGE CONTD.

63646676

Customized products Customized products Customized products

MeasurementDeflection Format Voltage range

E.g. 90° 144 x 144 100 V ± 25 %250° 96 x 96 100/ √3V ± 50 %

Page 18: DIGITAL PANEL METERS 3 ANALOGUE · PDF fileANALOGUE PANEL METERS ... Wattmeter Varmeter Product selection guide 63 92 DC Ammeter 90 Synchronization ... of static electricity on the

NORM

EURO

PE ran

geAn

alogu

e pa

nel m

eters

DeflectionFormat 48x48 72x72 96x96 144x144 48x48 72x72 96x96 144x144Shunt Scale 1.2 In5 A 0-6 A

10 A 0-12 A C90S 1400 C90S 1500

15 A 0-18 A

20 A 0-24 A

25 A 0-30 A C90S 1403 C90S 1503

30 A 0-36 A

40 A 0-48 A

50 A 0-60 A C90S 1406 C90S 1506

60 A 0-72 A

75 A 0-90 A C90S 1408 C90S 1508

100 A 0-120 A C90S 1409 C90S 1509

125 A 0-150 A

150 A 0-180 A C90S 1411 C90S 1511

200 A 0-240 A

250 A 0-300 A C90S 1413 C90S 1513

300 A 0-360 A

400 A 0-480 A

500 A 0-600 A C90S 1416 C90S 1516

600 A 0-720 A

1000 A 0-1200 A

Connection Deflection Format Zero position Rating Beginning/end of scale

E.g. direct 90° 72x72 left 60 A 0-60 Aprocess signal 250° 96x96 set 4-20 mA 0-1500 rpm

DeflectionAccuracy class: 1.5 (option class 1 except 48x48)Measuring component:Moving coilLinear scaleInterchangeable dial, except 144x144 Voltage drop:60 mV for 50 mA rating variable for rating < 50 mA

DeflectionAccuracy class: 1.5Measuring component:Moving coilLinear scaleVoltage drop:100 mV for 10 mA rating variable for rating < 10 mA

DeflectionFormat 48x48 72x72 96x96 144x144 48x48 72x72 96x96 144x144

Direct connection Zero position, left 50 mAor central to 20 A 50 µA to 75 A 500 µA to 12 A

Process signal connection Zero position set 4-20 mA 10-50 mA 2-10 mA 4-20 mA 10-50 mA 2-10 mA 4-23.2 mA

Shunt connection Zero position, 50 mV 60 mV 100 mV 120 mV 50 mV 60 mV 100 mV 120 mV left or central 150 mV 300 mV 360 mV 150 mV 300 mV

Feasibility limits

Direct connection

Connection on 100 mV shunt

DeflectionFormat 48x48 72x72 96x96 144x144 48x48 72x72 96x96 144x144Rating Scale5 A 0-5 A

10 A 0-10 A

15 A 0-15 A

25 A 0-25 A

178

Shunts Associated products

67

Accessories

T O O R D E R

NORMEUROPE RANGE DC Ammeter

Customized products

Page 19: DIGITAL PANEL METERS 3 ANALOGUE · PDF fileANALOGUE PANEL METERS ... Wattmeter Varmeter Product selection guide 63 92 DC Ammeter 90 Synchronization ... of static electricity on the

4

5

6

7

ENER

GY M

ETER

SPO

WER

MONITO

RSAN

ALOG

UEPA

NEL

METE

RSDIGITA

LPA

NEL

METE

RSTR

ANSD

UCER

SAN

D RE

CORD

ERS

TRAN

SFOR

MERS

SHUN

TSCO

NTRO

LLING

AND

RELA

YSAP

PEND

IX

3

2

1

DeflectionFormat 48x48 72x72 96x96 144x144 48x48 72x72 96x96 144x144Direct connection Zero position, left or central 50 mV to 600 V 50 mV to 600 V

Process signal connection Zero position, left from 50 mV from 50 mVSet zero position 1-5 V 2-10 V

DeflectionFormat 48x48 72x72 96x96 144x144 48x48 72x72 96x96 144x144Rating Scale15 V 0-15 V

30 V 0-30 V C90S 1425 C90S 1525

60 V 0-60 V C90S 1426 C90S 1526

75 V 0-75 V

150 V 0-150 V C90S 1428 C90S 1528 C250 1928

300 V 0-300 V

Deflection Format Zero position Rating Beginning / end of scale

E.g. 90° 72x72 left 75 V 0-75 V250° 48x48 central 400 V 400 V - 0 - 400 V

67

Accessories

Associated products

T O O R D E R

DeflectionAccuracy class: 1.5(option class 1 except 48x48)Measuring component:Moving coilLinear scaleConsumption:1 mA for Un ≥ 500 mV5 mA for Un < 500 mV

DeflectionAccuracy class: 1.5Measuring component:Moving coilLinear scaleConsumption:1 mA for Un ≥ 1 V 2 mA for Un ≥ 1 V (central zero) 5 mA for Un < 1 V

Feasibility limits

Direct connection

DC Voltmeter

7677

Customized products

SELECTION GUIDEINFO & ADVICE

RANGE INFORANGE CONTD.

63646678

Page 20: DIGITAL PANEL METERS 3 ANALOGUE · PDF fileANALOGUE PANEL METERS ... Wattmeter Varmeter Product selection guide 63 92 DC Ammeter 90 Synchronization ... of static electricity on the

NORM

EURO

PE ran

geAn

alogu

e pa

nel m

eters

177

CT Current transformers

Auxiliary Number Function Frequency Rating Graduation supply of relays Mode

178

Shunts

Associated products

T O O R D E R

DeflectionFormat : 96 x 96Accuracy class: 1.5Threshold index (with or without indicator)Consumption:I input: 1 VA (if AC); 100 mV (if DC)V input: 1 mA (if AC); 1 mA (if DC > 0.5 V and 5 mA if below) Relay: adjustable from 0 to 100 % of scale (accuracy threshold ± 1 %)Response time < 500 ms; Hysteresis: 1 % ± 0.5 %,Breaking capacity 5A / 230 V - 50 Hz - resistiveTriple insulationmeasurement / power / relay contacts: 2 kV - 50 Hz - 1mnAuxiliary power supplyTolerance: +10 %, -15 %; Frequency: 50 - 400 HzConsumption: 2.6 VA max

Direct or on CT 1 mA to 7.5 ADirect or on VTfrom 4 to 600Direct 1mA to 1Ashunt 50 to 300 mV Direct from 0.1to 400 VPt100 2/3 wireJKNST thermocouple

according to client

specifications

100 Vac to 400 Vac

24 Vdc to 125 Vdc

1 or 2 changeovercontact

A1 A2 B1 B2

Operating relay status

67

Accessories

TemperatureE.g. Pt100 3 wire / 0-120 °Cwith indicator

125 Vdc 1Rchangeover

contact

A2

NORMEUROPE RANGE Command functionmeter

Customized products

Feasibility limits

Frequency50 or 60 Hz

Left or centralzero position

Function Zero position Rating Graduation Auxiliary supply Number Modefrequency of relays

AC ammeter

AC voltmeter

DC ammeter

DC voltmeter

Temperature

Parameters to be specified when ordering

Page 21: DIGITAL PANEL METERS 3 ANALOGUE · PDF fileANALOGUE PANEL METERS ... Wattmeter Varmeter Product selection guide 63 92 DC Ammeter 90 Synchronization ... of static electricity on the

4

5

6

7

ENER

GY M

ETER

SPO

WER

MONITO

RSAN

ALOG

UEPA

NEL

METE

RSDIGITA

LPA

NEL

METE

RSTR

ANSD

UCER

SAN

D RE

CORD

ERS

TRAN

SFOR

MERS

SHUN

TSCO

NTRO

LLING

AND

RELA

YSAP

PEND

IX

3

2

1

636466

SELECTION GUIDEINFO & ADVICE

RANGE INFO

SYNCHRONIZATION COLUMN

7879

Synchronoscope

Vibrating-reed double frequency

meter

Differential voltmeter

Phasemeter

Synchro Couplerp124

Page 22: DIGITAL PANEL METERS 3 ANALOGUE · PDF fileANALOGUE PANEL METERS ... Wattmeter Varmeter Product selection guide 63 92 DC Ammeter 90 Synchronization ... of static electricity on the

LOGIC

rang

eAn

alogu

e pa

nel m

eters LOGIC RANGE

Square barrel analogue panel meters for all standard and special applications

Reference standards: IEC 60051-1,DIN 43700 (dimensions) DIN 43802 (scales)Accuracy class: 1.5 (± 1.5 % error margin at full scale)Front panel protection:IP 52 reference IEC 60529Dielectric test voltage:2 kV / 50 Hz / 1 mm, reference IEC 144Maximum operating voltage: 650 VacResistance to shocks: IEC 68-2-27Resistance to vibrations: IEC 60068-2-6Environment: IEC 68-1Reference temperature: 23 °C ± 2 °COperating temperature: -25 °C to +50 °CStorage temperature: -25 °C to +70 °CRelative humidity: < 90 % at 40 °CMounting:Panel thickness: 8 mm max.

Materials:Barrel: black ABS (metal on 144x144)Front: transparent PMM (glass on144x144 model)Flange: black ABSDial: light alloy, black markings on whitebackgroundBlack knife-blade pointer (aluminium) Operating position:Calibrated for vertical use (± 10°)Overloads:Voltmeter and frequency meter

- 1.2 Un permanent- 2 Un for 0.5 sAmmeters- 1.2 In permanent- 10 In for 1 sRemote end values:Safety recommendations EN 60 051-11 - 1.5 - 2 - 2.5 - 3 - 4 - 5 - 6 - 7.5 - 8and their decimal multiples and sub-multiples

General specifications:

86

Maximum demand ammeter

PRODUCT ADVANTAGES

WIDE RANGE OF FUNCTIONS and customized possibilities

NUMEROUS CLIENT REFERENCES from industrial sector in France and abroad

Accurate: more accurate readingsthanks to maximumlength pointer

Ergonomic.A simple mountingsystem for all typesof switchboards

IP65 kit for greaterfront-panel ingressprotection

82

AC ammeter

87

WattmeterVarmeter

88

Phasemeter

90

Synchronization instruments

92

DC ammeter

93

DC voltmeter

84

AC Voltmeter

85

Frequency meter

Page 23: DIGITAL PANEL METERS 3 ANALOGUE · PDF fileANALOGUE PANEL METERS ... Wattmeter Varmeter Product selection guide 63 92 DC Ammeter 90 Synchronization ... of static electricity on the

4

5

6

7

ENER

GY M

ETER

SPO

WER

MONITO

RSAN

ALOG

UEPA

NEL

METE

RSDIGITA

LPA

NEL

METE

RSTR

ANSD

UCER

SAN

D RE

CORD

ERS

TRAN

SFOR

MERS

SHUN

TSCO

NTRO

LLING

AND

RELA

YSAP

PEND

IX

3

2

1

Dimensions and drilling specifications

Mechanical specifications

Panel meter Additional unitFormat A x A 48x48 72x72 96x96 144x144 A B TransducerB (mm) 5.5 5.5 5.5 8C (mm) 43 x 43 66 x 66 90 x 90 136 x 136D (mm) 53 53 53 53D complete meter (mm) 108FxF (mm) 45 x 45 68 x 68 92 x 92 138 x 138FxF IP65 gasket (mm) 47 x 47 70 x 70 94 x 94G (mm) 63 105 105H (mm) 119 163 90P (mm) 88 92 58K (mm) 95 132M (mm) 55 95fitting points (4.5 mm) n2-n3 n1-n2-n4 DIN

Weight (approximate)90° and housing (kg) 0.10 0.20 0.25 0.35 0.25 1.10 0.30240° and 360° (kg) 0.21 0.30 0.35 0.45

Terminal Bare wire / Round or spade terminal Cage for 4mm2 wire

8081

SELECTION GUIDEINFO & ADVICE

RANGE INFORANGE CONTD.

63648082

Accessories

DeflectionFormat 48 x 48 72 x 72 96 x 96 144 x 144 72 x 72 96 x 96Panel tightnessPanel meter standard: front panel: IP52; housing: IP 20

Option sealed gasket IP65 front panel

DeflectionFormat 48 x 48 72 x 72 96 x 96 144 x 144 72 x 72 96 x 96Sealed gasket IP65 P01 311 001 P01 311 002 P01 311 003 P01 311 002 P01 311 003Adapter 72 x 72 and 48 x 48 P01 311 004 P01 311 004Adapter 96 x 96 and 72 x 72 P01 311 005 P01 311 005Adapter 96 x 96 and 48 x 48 P01 311 006 P01 311 006Antistatic liquid 9030 00676

Page 24: DIGITAL PANEL METERS 3 ANALOGUE · PDF fileANALOGUE PANEL METERS ... Wattmeter Varmeter Product selection guide 63 92 DC Ammeter 90 Synchronization ... of static electricity on the

Direct connection

LOGIC

rang

eAn

alogu

e pa

nel m

eters

T O O R D E R

DeflectionStandard scale modelAccuracy class: 1.5(option class 1, except 48x48)Measuring component: moving iron 40-60 HzPseudo linear scale (moving iron)Interchangeable dial

Motor scale modelAccuracy class: 1.5Measuring component: moving iron 40-60 HzPseudo linear scaleCalibrated 0-In up to 4/5 of deflection, beyond overload zone

DeflectionStandard scale modelAccuracy class: 1.5Measuring component: rectified moving coil 25-10,000 HzLinear scale Interchangeable dial

Motor scale modelAccuracy class: 1.5Measuring component: rectified moving coil 25-10,000 HzLinear scale Calibrated 0-In up to 4/5 of deflection, beyond overload zone

Feasibility limits

LOGIC RANGE AC Ammeter

DeflectionFormat 48x48 72x72 96x96 144x144 48x48 72x72 96x96 144x144Direct connectionStandard moving iron 0.5 to 30 Ascale moving coilMotor iron 5 In 0.5 to 30 Ascale coil 5 InConnection on CTStandard moving iron 1 A and 5 Ascale moving coil 1 A and 5 AMotor iron 5 In 1 A and 5 Ascale coil 5 In 1 A and 5 A

Consumption48 x 48: 0.3 to 0.8 VA72 x 72 / 96 x 96 / 144 x 144: 0.3 to 1.2 VA

Deflection Moving iron 50 Hz Format 48 x 48 72 x 72 96 x 96 144 x 144Rating scale In5 A 0-5 A LF4G 507X LF7G 507X LF9G 507X LF1G 507X10 A 0-10 A LF4G 511X LF7G 511X LF9G 511X LF1G 511X20 A 0-20 A LF4G 514X LF7G 514X LF9G 514X LF1G 514X30 A 0-30 A LF4G 516X LF7G 516X LF9G 516X LF1G 516XRating scale 5 In5 A 0-5/25 A LF4G 540X LF7G 540X LF9G 540X LF1G 540X10 A 0-10/50 A LF4G 542X LF7G 542X LF9G 542X LF1G 542X15 A 0-15/75 A LF4G 543X LF7G 543X LF9G 543X LF1G 543X20 A 0-20/100 A LF4G 544X LF7G 544X LF9G 544X LF1G 544X

Page 25: DIGITAL PANEL METERS 3 ANALOGUE · PDF fileANALOGUE PANEL METERS ... Wattmeter Varmeter Product selection guide 63 92 DC Ammeter 90 Synchronization ... of static electricity on the

4

5

6

7

ENER

GY M

ETER

SPO

WER

MONITO

RSAN

ALOG

UEPA

NEL

METE

RSDIGITA

LPA

NEL

METE

RSTR

ANSD

UCER

SAN

D RE

CORD

ERS

TRAN

SFOR

MERS

SHUN

TSCO

NTRO

LLING

AND

RELA

YSAP

PEND

IX

3

2

1

Connection on CT (complete panel meter)

Associated products

177

CT Current transformers

96

Ammeter switch

81

Accessories

8283

SELECTION GUIDEINFO & ADVICE

RANGE INFORANGE CONTD.

63648084

Deflection Moving ironFormat 48 x 48 72 x 72 96 x 96 144 x 144 72 x 72 96 x 96

Rating scale Always precise the CT ratio before ordering

CT / 5A In LF4G 507C LF7G 507C LF9G 507C LF1G 507C LM7L 401C LM9L 401C5 In LF4G 540C LF7G 540C LF9G 540C LF1G 540C LM7L 421C LM9L 421C

CT / 1A In LF4G 499C LF7G 499C LF9G 499C LF1G 499C LM7L 400C LM9L 400C5 In LF4G 541C LF7G 541C LF9G 541C LF1G 541C LM7L 420C LM9L 420C

Page 26: DIGITAL PANEL METERS 3 ANALOGUE · PDF fileANALOGUE PANEL METERS ... Wattmeter Varmeter Product selection guide 63 92 DC Ammeter 90 Synchronization ... of static electricity on the

LOGIC

rang

eAn

alogu

e pa

nel m

eters LOGIC RANGE AC Voltmeter

DeflectionFormat 48 x 48 72 x 72 96 x 96 144 x 144 48 x 48 72 x 72 96 x 96 144 x 144Direct connectionScale moving iron 15 to 500 VVn ; 1.2 Vn moving coil 15 to 500 V

Deflection Moving iron 50 Hz Format 48 x 48 72 x 72 96 x 96 144 x 144 72 x 72 96 x 96Rating Scale Vn15 V 0-15 V LF4G 550X LF7G 550X LF9G 550X LF1G 550X LM7L 430X LM9L 430X30 V 0-30 V LF4G 553X LF7G 553X LF9G 553X LF1G 553X LM7L 431X LM9L 431X60 V 0-60 V LF4G 556X LF7G 556X LF9G 556X LF1G 556X LM7L 432X LM9L 432X150 V 0-150 V LF4G 562X LF7G 562X LF9G 562X LF1G 562X LM7L 433X LM9L 433X250 V 0-250 V LF4G 564X LF7G 564X LF9G 564X LF1G 564X LM7L 434X LM9L 434X300 V 0-300 V LF4G 565X LF7G 565X LF9G 565X LF1G 565X LM7L 435X LM9L 435X500 V 0-500 V LF4G 567X LF7G 567X LF9G 567X LF1G 567X LM7L 436X LM9L 436X

Associated products

DeflectionStandard scale modelAccuracy class: 1.5Measuring component: moving iron40-60 HzPseudo linear scaleInterchangeable dial

DeflectionStandard scale modelAccuracy class: 1.5Measuring component:rectified moving coil 25-10,000 HzLinear scale Interchangeable dial

Consumption48 x 48: 1.2 to 2 VA72 x 72 / 96 x 96 / 144 x 144: 1.5 to 4 VA

Feasibility limits

Direct connection

96

Voltmeter switch

81

Accessories

T O O R D E R

Page 27: DIGITAL PANEL METERS 3 ANALOGUE · PDF fileANALOGUE PANEL METERS ... Wattmeter Varmeter Product selection guide 63 92 DC Ammeter 90 Synchronization ... of static electricity on the

4

5

6

7

ENER

GY M

ETER

SPO

WER

MONITO

RSAN

ALOG

UEPA

NEL

METE

RSDIGITA

LPA

NEL

METE

RSTR

ANSD

UCER

SAN

D RE

CORD

ERS

TRAN

SFOR

MERS

SHUN

TSCO

NTRO

LLING

AND

RELA

YSAP

PEND

IX

3

2

1

81

Accessories Associated products

Feasibility limitsVoltage 100 V to 400 V

Pointer frequency meter

Deflection

Accuracy class: 0.5 of nominal frequencyLinear scaleMeasuring component: moving coil and frequency converterOperating range: 0.80 to 1.2 UnConsumption: 1.5 VA

T O O R D E R

Feasibility limitsVoltage 100 V to 400 V

Vibrating reed frequency meter Accuracy class: 0.5Measuring component: vibrating reed in field of coilAmplitude of vibration proportional to V2

Operating range: 0.90 Un to 1.1 UnConsumption:100 V: 1.5 VA230 V: 3 VA400 V: 4 VA

Frequency meter

8485

SELECTION GUIDEINFO & ADVICE

RANGE INFORANGE CONTD.

63648086

DeflectionFormat 48x48 72x72 96x96 144x144Nominal Measurementvoltage range100 V 45-65 Hz LA4G 012X LA7G 012X LA9G 012X LA1G 012X230 V 45-65 Hz LA4G 013X LA7G 013X LA9G 013X LA1G 013X400 V 45-65 Hz LA4G 014X LA7G 014X LA9G 014X LA1G 014X

9 blades segmentsFormat 72x72 96x96Nominal Measurementvoltage range

100 V 47-53 Hz LL7N 600X LL9N 600X57-63 Hz LL7N 601X LL9N 601X

230 V 47-53 Hz LL7N 602X LL9N 602X57-63 Hz LL7N 603X LL9N 603X

400 V 47-53 Hz LL7N 604X LL9N 604X57-63 Hz LL7N 605X LL9N 605X

Page 28: DIGITAL PANEL METERS 3 ANALOGUE · PDF fileANALOGUE PANEL METERS ... Wattmeter Varmeter Product selection guide 63 92 DC Ammeter 90 Synchronization ... of static electricity on the

LOGIC

rang

eAn

alogu

e pa

nel m

eters

177

CT Current transformers

81

Accessories

Connection on CT

T O O R D E R

Deflection

Accuracy class: 3

Measurement component: spiralled double reed (I rms avg.)

Frequency : 45-65 Hz

Interchangeable dial

Overload capacity: 1.2 In permanent10 In for 0.5 s

Consumption: 2.5 VA

Pointer guided by measuring component and adjustable using front panel button.

Maximum demandammeter

Associated products

Primary CT Code

400 A LI9G 011C

Customized productsE.g.

Parameters to be specified when ordering

LOGIC RANGE

Integration Deflectiontime

Rating Graduation72x72 96x96

8 mn 6 A LI7G 011C LI9G 011C15 mn 6 A LI7G 012C LI9G 012C

according to primary CT / 5 A

Page 29: DIGITAL PANEL METERS 3 ANALOGUE · PDF fileANALOGUE PANEL METERS ... Wattmeter Varmeter Product selection guide 63 92 DC Ammeter 90 Synchronization ... of static electricity on the

4

5

6

7

ENER

GY M

ETER

SPO

WER

MONITO

RSAN

ALOG

UEPA

NEL

METE

RSDIGITA

LPA

NEL

METE

RSTR

ANSD

UCER

SAN

D RE

CORD

ERS

TRAN

SFOR

MERS

SHUN

TSCO

NTRO

LLING

AND

RELA

YSAP

PEND

IX

3

2

1

8687

SELECTION GUIDEINFO & ADVICE

RANGE INFORANGE CONTD.

63648088

ConverterAccuracy: : 1 % upwards of 5 % of SnOperating range: between 0.5 and 1.35 SnFrequency : 45 to 65 HzOverload capacity:Circuit current: 2 In permanent

5 In for 3 sCircuit voltage: 1.2 Un permanent

1.5 Un for 3 sConsumption: Current input 0.5 VA

Voltage input 1 VAAuxiliary power supply:Vac = 4 VA max - Vdc = 3 W

Panel meterAccuracy class: 1.5Measuring component:Moving coilLinear scaleInterchangeable dial

T O O R D E R

Measurement Analogue Auxiliary Power Network Model Current Voltage range output supply

Single phase MW MBalanced three-phase 3 wires MW 33EUnbalanced three-phase 3 wires MW 33NEBalanced three-phase 4 wires MW 34EUnbalanced three-phase 4 wires MW 34NESingle phase MVAR MBalanced three-phase 3 wires MVAR 33EUnbalanced three-phase 3 wires MVAR 33NEBalanced three-phase 4 wires MVAR 34EUnbalanced three-phase 4 wires MVAR 34NE

Panel meter

Converter

active

on CT1 or 5 A

direct 230 Vor 400 V

on TT :100/√3 V110/√3 V - 100 V 110 V - 230 V or400 V

Beginning/end of scale

Absorbed orgenerated

0 - 20 mAor

4 - 20 mA

24 Vac48 Vac110 Vac230 Vac24 Vdc48 Vdcreactive

Parameters to be specified when ordering

81

Accessories

Associated products

177

CT Current transformers

168

Power converters

Connection diagramConsult us

Customized products

E.g.

Transducer Voltage or Beginning/end Aux.Panel meter model CT ratio Direct / VT VT ratio of scale supply

LM9L 501C MW34NE 500/5A VT 20 kV / 110 V -20…+20 MW 110 Vac

DeflectionFormat 72 x 72 96 x 96 72x72 96x96Rating 0 -20 mA 0 left LM7G 134C LM9G 134C LM7L 501C LM9L 501C4 -20 mA 4 mA offset mode LM7G 157C LM9G 157C LM7L 500C LM9L 500C

WattmeterVarmeter

Page 30: DIGITAL PANEL METERS 3 ANALOGUE · PDF fileANALOGUE PANEL METERS ... Wattmeter Varmeter Product selection guide 63 92 DC Ammeter 90 Synchronization ... of static electricity on the

LOGIC

rang

eAn

alogu

e pa

nel m

eters LOGIC RANGE

Panel meterAccuracy class: 1.5Measuring component:Moving coilLinear scale1.5 (single phase)2.5 (three-phase)Interchangeable dial Complete instrumentsAccuracy class: 1.5

ConverterAccuracy: 1 % upwards of 10 % of In and VnOperating range: from 0.1 Un to 1.2 UnIntensity: 0.1 In to 1.2 InFrequency: 45 to 65 HzOverload capacity:Input current: 2 In permanent

5 In for 3 sInput voltage: 1.2 Un permanent

1.5 Un for 3 sConsumption:Input current: 0.5 VA Input voltage: 1 VA

Auxiliary supply:Vac = 4 VA max - Vdc = 3 W

DeflectionFormat 72 x 72 96 x 96 72x72 96x96Rating 0 -20 mA 0 left LM7G 134C LM9G 134C LM7L 501C LM9L 501C4 -20 mA 4 mA offset mode LM7G 157C LM9G 157C LM7L 500C LM9L 500C

Panel meter

Measurement Analogue AuxiliaryNetwork Model Current Voltage range output supplySingle phase MPHI MBalanced three-phase 3 wires MPHI 33E

Unbalanced three-phase 3 wires MPHI 34E

Transducer

1 or 5 A

Highest100 V 150 V250 V 440 V

0.5 cap/1/0.5 ind0.8 cap/1/0.3 ind

0 - 20 mAor4 - 20 mA

Parameters to be specified when ordering

81

Accessories

Associated products

Phasemeter

T O O R D E R

Connection diagramConsult us

Customized products

Transducer Highest Begging/end AuxiliaryPanel meter Model Current Voltage of scale supply

E.g. LM7G 134C MPHI33E 1 A 440 V 0.5 lead/1/0.5 lag 230 Vac

24 Vac 48 Vac110 Vac 230 Vac24 Vdc 48 Vdc

Page 31: DIGITAL PANEL METERS 3 ANALOGUE · PDF fileANALOGUE PANEL METERS ... Wattmeter Varmeter Product selection guide 63 92 DC Ammeter 90 Synchronization ... of static electricity on the

4

5

6

7

ENER

GY M

ETER

SPO

WER

MONITO

RSAN

ALOG

UEPA

NEL

METE

RSDIGITA

LPA

NEL

METE

RSTR

ANSD

UCER

SAN

D RE

CORD

ERS

TRAN

SFOR

MERS

SHUN

TSCO

NTRO

LLING

AND

RELA

YSAP

PEND

IX

3

2

1

8889

SELECTION GUIDEINFO & ADVICE

RANGE INFORANGE CONTD.

63648090

Network Measurement range Current Voltage 96x96100 V LP9N 300X LP9N 303X

Single phase 0.5 cap / 1 / 0.5 ind 5 A 230 V LP9N 301X LP9N 304X400 V LP9N 302X LP9N 305X100 V LP9N 306X LP9N 309X

Balanced three- 0.5 cap / 1 / 0.5 ind 5 A 230 V LP9N 307X LP9N 310Xphase 3 wires 400 V LP9N 308X LP9N 311X

Phasemeter

Complete instrument (integrated converter)

Connection diagramSingle phase network

Direct connection Connection via CT / 5A Connection via CT / 5A and VT (…/100 V)

S1 S2

P1 P2L1N

S1

P1

S2

P2

2 311 1

S1 S2

P1 P2L1N

2 311 1

Direct connection Connection via CT / 5A Connection via CT / 5A and VT (…/100 V)

Three-phase network

Associated products

177

CT Current transformers

168

Power converters

Page 32: DIGITAL PANEL METERS 3 ANALOGUE · PDF fileANALOGUE PANEL METERS ... Wattmeter Varmeter Product selection guide 63 92 DC Ammeter 90 Synchronization ... of static electricity on the

LOGIC

rang

eAn

alogu

e pa

nel m

eters

81

Accessories Associated products

LOGIC RANGE

Accuracy class: 3° (∆ϕ = 0)with 20° between LEDs for 360° displayand 5° between LEDs for display ± 15°around synchronizationThree phase network:2-wire connectionConsumption:Circuit reference 4 mAOperating range: 0.8 Vn to 1.2 VnOverload capacity:1.2 Vn permanent 2 Vn for 3 sSynchronization relay:NO: 250 V/50 Hz-6 A Make time: 120 ms

Accuracy class: 0.5Consumption: 4 VA max.Operating range:0.9 Un to 1.1 UnMeasurement component:vibrating reed in field of coil

Accuracy class: 1.5Consumption: 1.5 VAFrequency : 45-65 HzMeasurement range: moving ironPseudo linear scale

LED synchronoscope Vibrating-reed doublefrequency

meter

Double Voltmeter

Feasibility limitsVoltage 100/√3 to 400 V

Feasibility limitsVoltage 100/√3 to 400 V Frequency 47/53 Hz and 57/63 Hz

Feasibility limitsVoltage 2x500V max.

DeflectionFormat 96 x 96Frequency Voltage

100/√3 V LS9N 401X2-wire 100 V LS9N 402X45-65 Hz 230 V LS9N 403X

400 V LS9N 404X

DeflectionFormat 96 x 96Voltageend scale2 x 250 V LH9N 101X2 x 500 V LH9N 102X

2 rows of 13 segmentsFormat 96 x 96Frequency Voltage

100/√3 V LQ9N 311X

47-53 Hz 100 V LQ9N 312X230 V LQ9N 313X400 V LQ9N 314X100/√3 V LQ9N 411X

57-63 Hz 100 V LQ9N 412X230 V LQ9N 413X400 V LQ9N 414X

T O O R D E R

Page 33: DIGITAL PANEL METERS 3 ANALOGUE · PDF fileANALOGUE PANEL METERS ... Wattmeter Varmeter Product selection guide 63 92 DC Ammeter 90 Synchronization ... of static electricity on the

4

5

6

7

ENER

GY M

ETER

SPO

WER

MONITO

RSAN

ALOG

UEPA

NEL

METE

RSDIGITA

LPA

NEL

METE

RSTR

ANSD

UCER

SAN

D RE

CORD

ERS

TRAN

SFOR

MERS

SHUN

TSCO

NTRO

LLING

AND

RELA

YSAP

PEND

IX

3

2

1

Consumption: 1 mAFrequency: 50-60 HzMeasuring component:rectified moving coilEnd of scale corresponds to double the nominal voltage

Panel meterAccuracy class: 1.5Measuring component: moving coilLinear scale ConverterAccuracy: 2 % of VnFrequency: 45 to 65 HzOverload: 1.2 Vn permanent

2 Vn for 3 secConsumption: measurement: 0.5 VAauxiliary supply - Vac: 4 Vac max,Vdc: 3 W

Accury class: 0.5Detection by electronic circuit connected on three phasesDisplay: green lamp lit if order correct, red lamp lit order incorrectFrequency: 50-60 HzConsumption: 1.5 VA

Zero voltmeter

Differential voltmeter

Phase rotationsequence

panel meter

T O O R D E R

Synchronization instruments

Measurement Aux.Panel meter Voltage range supply

E.g. LM9G 134C 250 V ±15 % 24 Vdc

Connection diagramConsult us

DeflectionFormat 72x72 96x96Voltage3x100 V to 600V LO7N 101X LO9N 101X

DeflectionFormat 96x96Voltage2x800 V LZ9G 005X

Format 96x96 96x96Rating Zero0-20mA left LM9G 134C LM9L 501C

Panel meter

TransducerModel voltage measurement analogue auxiliary

range output supplythe 24 Vac

highest 48 Vac

MDIF 100 V ±25 % 0-20mA 110 Vac150 V 230 Vac250 V 24 Vdc400 V 48 VdcParameters to be specified when ordering

Feasibility limitsVoltage 800 V

Feasibility limitsPanel meter: other formats and deflection, other measurement ranges.

Feasibility limitsVoltage 150 to 600 V

9091

SELECTION GUIDEINFO & ADVICE

RANGE INFORANGE CONTD.

63648092

Customized products

81

Accessories Associated products

Page 34: DIGITAL PANEL METERS 3 ANALOGUE · PDF fileANALOGUE PANEL METERS ... Wattmeter Varmeter Product selection guide 63 92 DC Ammeter 90 Synchronization ... of static electricity on the

LOGIC

rang

eAn

alogu

e pa

nel m

eters

T O O R D E R

DeflectionAccuracy class: 1.5 Measuring component: moving coilLinear scaleInterchangeable dialVoltage drop:60 mV

DeflectionAccuracy class: 1.5Measuring component: moving coil Linear scaleInterchangeable dialVoltage drop:60 mV

Feasibility limitsDeflectionFormat 48x48 72x72 96x96 144x144 48x48 72x72 96x96 144x144Direct connection Zero position, left 5 to 25 A 5 to 25 AProcess signal connection Zero position, left / offset 0-20 mA / 4-20 mA 0-20 mA and 4-20 mAShunt connection Zero position, left 50 to 100 mV 50 to 100 mV

LOGIC RANGE DC Ammeter

Connection Deflection Format Rating Beginning/end of scale

E.g. Process signal 90° 72x72 5 mA 0-100 km/h

Customized products

Direct connection

Connection on shunt

Complete panel meter Deflection DeflectionFormat 48 x 48 72 x 72 96 x 96 144 x 144 72 x 72 96 x 96Rating Scale5 A 0-5 A LM4G 180X LM7G 180X LM9G 180X LM1G 180X LM7L 502X LM9L 502X10 A 0-10 A LM4G 184X LM7G 184X LM9G 184X LM1G 184X LM7L 503X LM9L 503X15 A 0-15 A LM4G 187X LM7G 187X LM9G 187X LM1G 187X LM7L 504X LM9L 504X25 A 0-25 A LM4G 188X LM7G 188X LM9G 188X LM1G 188X LM7L 505X LM9L 505X

Always specify nominal current of shunt when ordering0-20 mA Process LM4G 134C LM7G 134C LM9G 134C LM1G 134C LM7L 501C LM9L 501C4-20 mA Process LM4G 157C LM7G 157C LM9G 157C LM1G 157C LM7L 500C LM9L 500C

Complete panel meter Deflection DeflectionFormat 48 x 48 72 x 72 96 x 96 144 x 144 72 x 72 96 x 96Rating Zero Always specify nominal current of shunt when ordering50 mV Left LM4G 310C LM7G 310C LM9G 310C LM1G 310C LM7L 510C LM9L 510C60 mV Left LM4G 311C LM7G 311C LM9G 311C LM1G 311C LM7L 511C LM9L 511C100 mV Left LM4G 314C LM7G 314C LM9G 314C LM1G 314C LM7L 512C LM9L 512C

Page 35: DIGITAL PANEL METERS 3 ANALOGUE · PDF fileANALOGUE PANEL METERS ... Wattmeter Varmeter Product selection guide 63 92 DC Ammeter 90 Synchronization ... of static electricity on the

4

5

6

7

ENER

GY M

ETER

SPO

WER

MONITO

RSAN

ALOG

UEPA

NEL

METE

RSDIGITA

LPA

NEL

METE

RSTR

ANSD

UCER

SAN

D RE

CORD

ERS

TRAN

SFOR

MERS

SHUN

TSCO

NTRO

LLING

AND

RELA

YSAP

PEND

IX

3

2

1

81

Accessories

Associated products

DeflectionAccuracy class: 1.5Measurement component: moving coilLinear scaleInterchangeable dialConsumption: 100 Ω / V

DeflectionAccuracy class: 1.5Measurement component: moving coilLinear scaleInterchangeable dialConsumption: 100 Ω / V

Feasibility limitsDeflectionFormat 48x48 72x72 96x96 144x144 72x72 96x96Direct connection Left zero position 15 to 300 V 15 to 300 VProcess signal connection Left zero position 1 to 10 V 1 to 10 V

T O O R D E R

DC Voltmeter

9293

SELECTION GUIDEINFO & ADVICE

RANGE INFO

636480

Customized productsConnection Deflection Format Rating Beginning/end of scale

E.g. Process signal 240° 72x72 1-5 V 0-100 N.m

Direct connection

Process signal connectionDeflectionFormat 48 x 48 72 x 72 96 x 96 144 x 144 72 x 72 96 x 96Rating Scale Always specify nominal current of shunt when ordering0-1 V Process LM4G 340C LM7G 340C LM9G 340C LM1G 340C LM7L 513C LM9L 513C0-10 V Process LM4G 354C LM7G 354C LM9G 354C LM1G 354C LM7L 514C LM9L 514C

DeflectionFormat 48 x 48 72 x 72 96 x 96 144 x 144 72 x 72 96 x 96Rating Scale15 V 0-15 V LM4G 357X LM7G 357X LM9G 357X LM1G 357X LM7L 515X LM9L 515X30 V 0-30 V LM4G 362X LM7G 362X LM9G 362X LM1G 362X LM7L 516X LM9L 516X60 V 0-60 V LM4G 365X LM7G 365X LM9G 365X LM1G 365X LM7L 517X LM9L 517X75 V 0-75 V LM4G 366X LM7G 366X LM9G 366X LM1G 366X LM7L 518X LM9L 518X150 V 0-150 V LM4G 371X LM7G 371X LM9G 371X LM1G 371X LM7L 519X LM9L 519X300 V 0-300 V LM4G 375X LM7G 375X LM9G 375X LM1G 375X LM7L 520X LM9L 520X

Page 36: DIGITAL PANEL METERS 3 ANALOGUE · PDF fileANALOGUE PANEL METERS ... Wattmeter Varmeter Product selection guide 63 92 DC Ammeter 90 Synchronization ... of static electricity on the

TO ORDER

HOUR

MET

ERSAn

alogu

e pa

nel m

eters COHO RANGE

Hour meters for totalling the operating time of machines or equipment for control and maintenance

Reference standard: NFC 42310Display: without reset function, whiteon black background, decimals in redHeight of digits: 4 mmAC and DC capacity: 99,999.99 hOperating indicator: scrolling 1/100hevery 36 sMotor in Vac/Vdc: pulse + electroniccounterConsumption:0.5 VA in 24 Vac/dc, 1.5 VA in 48 Vac/dc,2 VA in 110/230 Vac, 6 VA in 400 VacOperating range:Voltage Vac: -15 % +10 %Frequency: ± 5 HzVoltage Vdc: ± 20 %

Insulation: doubleDielectric test voltage:5.5 kV - 50 Hz - 1 minEnvironment:Operating temperature: -10 °C to +60 °CRelative humidity: < 95 % to +45 °CProtection rating on front panel:standard: IP50, option: IP55Electromagnetic compatibility(transmission and immunity): EN 61326-1Fitting:Standard version: elastic jointIP55 version: joint + strapWeight: 180 gConnection: 6.35 Faston clips + terminal covers included

General specifications

Hour meter

PRODUCT ADVANTAGES

FOR SEVERE ENVIRONMENTS

ENHANCED RELIABILITY RANGE

Format 48x48 (IP50) 48x48 (IP55)Frequency Voltage

24 V COHO 0606 COHO 1606

50 Hz 48 V COHO 0607 COHO 1607110 V COHO 0608 COHO 1608230/400 V COHO 0610 COHO 161024 V COHO 0627 COHO 1627

60 Hz 48 V COHO 0628 COHO 1628110 V COHO 0629 COHO 1629230/400 V COHO 0631 COHO 1631

direct 24 V COHO 0604 COHO 160448 V COHO 0605 COHO 1605

Page 37: DIGITAL PANEL METERS 3 ANALOGUE · PDF fileANALOGUE PANEL METERS ... Wattmeter Varmeter Product selection guide 63 92 DC Ammeter 90 Synchronization ... of static electricity on the

4

5

6

7

ENER

GY M

ETER

SPO

WER

MONITO

RSAN

ALOG

UEPA

NEL

METE

RSDIGITA

LPA

NEL

METE

RSTR

ANSD

UCER

SAN

D RE

CORD

ERS

TRAN

SFOR

MERS

SHUN

TSCO

NTRO

LLING

AND

RELA

YSAP

PEND

IX

3

2

1

9495

6364

SELECTION GUIDEINFO & ADVICE

TO ORDER

LK RANGEHour meters (7 or 8 digits) for totalling the operating time of machines or equipment for control and maintenance

General specifications

Hour meter

PRODUCT ADVANTAGES

EASY TO INSTALL

ECONOMICAL

Format 48x48 55x55 72x72Frequency Voltage50 Hz 24 V LK4N 001N LK5N 001N LK7N 001N

48 V LK4N 003N LK5N 003N LK7N 003N115 V LK4N 005N LK5N 005N LK7N 005N230 V LK4N 007N LK5N 007N LK7N 007N400 V LK4N 009N LK5N 009N LK7N 009N

60 Hz 24 V LK4N 002N LK5N 002N LK7N 002N48 V LK4N 004N LK5N 004N LK7N 004N115 V LK4N 006N LK5N 006N LK7N 006N230 V LK4N 008N LK5N 008N LK7N 008N400 V LK4N 010N LK5N 010N LK7N 010N

Direct 12-24 V LK4N 011N LK5N 011N LK7N 011N36-60 V LK4N 012N LK5N 012N LK7N 012N110 V LK4N 013N LK5N 013N LK7N 013N

front panel only LK5N 0000 LK7N 0000Ø 50.5

(except 48x48) (48x48)

Panel drilling

Reference standard: NFC 42310Display: without reset function, white on black background, decimals in redHeight of digits: 4 mmAC capacity: 99,999.99 hDC capacity: 999,999.99 hOperating indicator in Vac: ridged rollOperating indicator in Vdc: continuous scrolling 1/100h every 36 sMotor in Vac: synchronousMotor in Vdc: step-by-stepConsumption: Vdc: ≤ 750 mWVac:≤ 1.65 VA

Insulation: singleDielectric test voltage: 2 kV - 50 Hz - 1 mnOperating range:Voltage Vac: ± 10 %Frequency: ± 10 %Voltage Vdc: ± 10 %Environment:Operating temperature: -15 °C to +50 °CRelative humidity: < 95 % at +45 °CProtection rating on front panel: IP52Fitting: auto-block flangeWeight: 50 gConnection: 6.35 lugs or Faston clips

Page 38: DIGITAL PANEL METERS 3 ANALOGUE · PDF fileANALOGUE PANEL METERS ... Wattmeter Varmeter Product selection guide 63 92 DC Ammeter 90 Synchronization ... of static electricity on the

Associa

ted p

rodu

ctsAn

alogu

e pa

nel m

eters SWITCHES

TO ORDER

Format 48x48ModelCurrent 1990 1300Voltage ph-ph 1990 1100Voltage ph-n 1990 1101Voltage ph-ph/ph-n 1990 1200

This instruments successively switches the voltage or current froman LV network or current transformer to an analogue or digitalpanel meter without a power outage or short-circuit.

Reference standard: IEC 60947-3Angle shift between two positions ofswitching device: 90° (45° if 7 positions)Maximum current: 16 AMaximum voltage: 660 VTest voltage between contacts

and ground connections:2.5 kV - 50 Hz - 1 mmProtection: IP 40 Fitting: by screws providedWeight: 125gConnection: by lug for 2.5 mm2 wire

General specifications

Dimensions

Connection diagram

The CVAI range

PRODUCT ADVANTAGES EASY TO INSTALL

FRONT PANEL ADAPTED TO PANEL METER DESIGN

ERGONOMIC