25
Development of an Aerogel Cherenkov Counter for the J-PARC E16 Upgrade F.Sakuma (RIKEN), M.Nakamura (TITECH), H.Kawai (Chiba-U), H.Ohnishi (RIKEN), M.Tabata (JAXA), M.Tokuda (TITECH) Motivation Aerogel Cherenkov Counter Present Status Summary 新新新新新 新新新新新新新新新新新新新新新新新新新新新新新新新新新新新 新新新新新 「」 @ 新新 2011/02/28-03/01 課課課課22105516 課課 22 課課23 課課課課課課課 課課課 課課 課課課課課課課 ()

Development of an Aerogel Cherenkov Counter for the J-PARC E16 Upgrade

  • Upload
    felton

  • View
    114

  • Download
    1

Embed Size (px)

DESCRIPTION

課題番号: 22105516 (平成 22 年度~ 23 年度) 研究代表者:佐久間 史典(理化学研究所). Development of an Aerogel Cherenkov Counter for the J-PARC E16 Upgrade . F.Sakuma (RIKEN), M.Nakamura (TITECH), H.Kawai (Chiba-U), H.Ohnishi (RIKEN), M.Tabata (JAXA), M.Tokuda (TITECH). Motivation Aerogel Cherenkov Counter - PowerPoint PPT Presentation

Citation preview

Page 1: Development of an  Aerogel  Cherenkov Counter for the J-PARC E16 Upgrade

Development of an Aerogel Cherenkov Counter for the J-PARC E16 Upgrade

F.Sakuma (RIKEN), M.Nakamura (TITECH), H.Kawai (Chiba-U), H.Ohnishi (RIKEN), M.Tabata (JAXA), M.Tokuda (TITECH)

Motivation Aerogel Cherenkov Counter Present Status Summary

新学術領域「多彩なフレーバーで探る新しいハドロン存在形態の包括的研究」 領域研究会 @ 理研 2011/02/28-03/01

課題番号: 22105516(平成 22年度~ 23年度)研究代表者:佐久間 史典(理化学研究所)

Page 2: Development of an  Aerogel  Cherenkov Counter for the J-PARC E16 Upgrade

2

MotivationJ-PARC E16 experiment measures in-medium f-meson modification in di-electron spectrum

K+K- measurement in the E16 experiment is very important

topics of the f-meson di-lepton spectrum Gll vs GKK (f-puzzle)

installation of Kaon detectors in the E16

spectrometer is desired

NA60

NPA830,753c(2009).

PLB262,485(1991).

Br*(fll)/Br0(fll)

density (rCR/r0)

Do decay widths offll / KK change in

nuclear matter caused byf / K spectral modification?

Theory

Page 3: Development of an  Aerogel  Cherenkov Counter for the J-PARC E16 Upgrade

3

Forward Kaon Spectrometersegmented STC

AC(n=1.034) + TOF counter

+15

-15

+15

-15+45 -45

e+e- acceptanceK+K- acceptance

--- Requirements ---1. threshold type AC for kaon trigger

(veto counter)2. work in magnetic field3. small & compact

Page 4: Development of an  Aerogel  Cherenkov Counter for the J-PARC E16 Upgrade

4

fe+e-/K+K- acceptance

y(CM)

pT

(LAB)

bg(LAB)

pt vs. y

− e-accepted (double-arm)− e-accepted (single-arm)− k-accepted (opposite-module pair)− k-accepted (same-module pair)− k-accepted (neighbor-module

pair)

fe+e-

double-armfK+K-

neighbor-side

y(LAB)

pT

(LAB)

bg(LAB)

pt vs. y

E325 acceptance

Improvement of the acceptance overlap between e+e- and K+K-

Page 5: Development of an  Aerogel  Cherenkov Counter for the J-PARC E16 Upgrade

5

index=1.034integration range :

300-800nm

index=1.034

use n=1.034, as same as KEK-PS E325

60x60cm2 divided by 6 (or 10) sectors10cm

60cm

readoutWLS + fiber + (FM)PMT

AC design

Goal : construct a prototype of ¼ size module

X 4 modules

Page 6: Development of an  Aerogel  Cherenkov Counter for the J-PARC E16 Upgrade

6

Some Hints in detector development in Russia?

arXiv:hep-ex/0106016

endcapbarrel

Aerogel : t74mm, n=1.05WLS : BBQ

~8 p.e.

p momentum

candidate for PEP-N detector @ SLAC

Page 7: Development of an  Aerogel  Cherenkov Counter for the J-PARC E16 Upgrade

7

Minimum Goal : KEK-PS E325 ACAC

• n=1.034• 12.5cm Aerogel• 5 inch PMT (H6527)

1.1 p.e.

proton

pion8 p.e.

M.Ishino et al., NIM A457, 581

p Rejection : 1x10-2

@ 1.4GeV/c

Page 8: Development of an  Aerogel  Cherenkov Counter for the J-PARC E16 Upgrade

8

0

1

2

3

4

5

6

0 2 4 6 8 10

mea

n #

of p

hoto

elec

tron

thickness of Aerogel [cm]

PanasonicE325Chiba-U

Aerogel

H6410 (2”)

Cosmic Ray

Aerogel

Mirror

We have checked 3-types of the aerogel (n~1.034):Panasonic-denkoKEK-PS E325Chiba-U

10cm10cm

Page 9: Development of an  Aerogel  Cherenkov Counter for the J-PARC E16 Upgrade

9

WLS

10cm

30cm

H6410(2”)

fiber x100

WLS

PMT

Cosmic Ray WLS (ELJEN EJ-299-27, t1mm)

Aerogel (t2cm)

clear fiber x100(f1mm, single clad)

expected # of photon@ 1GeV/c p & n=1.034

transmission lengthn=1.034 (KEK)

10cm

xWLS(blue)

PMT

Page 10: Development of an  Aerogel  Cherenkov Counter for the J-PARC E16 Upgrade

10

WLS (Cont’d)

fitting is failed…

w/ Aerogel

w/o Aerogelw/o Aerogel

w/ Aerogel

2cm2cm

1mm

1mm1mm

Page 11: Development of an  Aerogel  Cherenkov Counter for the J-PARC E16 Upgrade

11

WLS (Cont’d)

--- What we have learned ---WLS (blue, t1mm) emits several photons with charged

particles We cannot install a large amount of WLS in detector acceptancepresent method of WLS+fiber readout cannot

collect Cherenkov light from the Aerogel

--- What we have to do ---reconsider the configuration of the Aerogel and WLSincrease the fibers?usage of blue and green WLS?

Page 12: Development of an  Aerogel  Cherenkov Counter for the J-PARC E16 Upgrade

12

Other Ways …

R5543 x 52 @ RIKEN(from KEK-PS E325 GC)

BELLE ACNIM A453,321

development of a “normal type” Aerogel Cherenkov Counter with finemesh-PMTs such as BELLE AC.

development of a “reflection type” Aerogel Cherenkov Counter with optical mirrors such as E325 AC.

E325 ACNIM A457, 581

Page 13: Development of an  Aerogel  Cherenkov Counter for the J-PARC E16 Upgrade

13

Summary

We have been developing an Aerogel Cherenkov Counter for the E16 upgrade in order to measure K+K- pair.

Development of WLS+fiber readout has been started, but we have to adjust the configuration of AC+WLS+fiber. Further study is required…

Page 14: Development of an  Aerogel  Cherenkov Counter for the J-PARC E16 Upgrade

14

Page 15: Development of an  Aerogel  Cherenkov Counter for the J-PARC E16 Upgrade

15

Expected Photon Spectra

expected # of photon@ 1GeV/c p & n=1.034

transmission lengthn=1.034 (E325)

Aerogel

Detection

xp 1GeV/c

Aerogel

Detection

l

p 1GeV/c

Page 16: Development of an  Aerogel  Cherenkov Counter for the J-PARC E16 Upgrade

16

WLS (Cont’d)

WLS1mm

Aerogel 6cm

H6410 (2”)

Aerogel 6cm

Page 17: Development of an  Aerogel  Cherenkov Counter for the J-PARC E16 Upgrade

17

WLS (Cont’d)

PMT300~600nm

WLS300~400nm

Aerogel

Detection

l

p 1GeV/cWLS(blue)

PMT

Page 18: Development of an  Aerogel  Cherenkov Counter for the J-PARC E16 Upgrade

18

WLS (Cont’d)

H6410 (2”)

Aerogel 9.4cm

trigger

trigger

Aerogel 9.4cm

WLS1mm

trigger

trigger

Page 19: Development of an  Aerogel  Cherenkov Counter for the J-PARC E16 Upgrade

19

Photon Fitting

20 1211

exp 1 exp! 22

n

n

x p npf x C

n nn

p

Poisson Gaussian

C : normalized factor : mean value of photoelectronp0 : pedestal peakp1 : distance of pedestal to single-photon 1 : PMT resolution for single-photon

parameter parameter constant

constant

constant

Page 20: Development of an  Aerogel  Cherenkov Counter for the J-PARC E16 Upgrade

20

SiAPD

S8664-1010S8664-55

H4083

We purchased and tested SiAPDs.

But we CANNOT see the signal of a few photons on SiAPD, because of read-out electronics noise!

~7500 photons(gain : x50)

what we have learned is …“using low-gain devices for

Cherenkov detection is awful difficult!”

Page 21: Development of an  Aerogel  Cherenkov Counter for the J-PARC E16 Upgrade

21

MPPCS10362

-11-100C

S10362-33-100C

S10362-33-050CS10362

-33-025C

We purchased and tested MPPCs.

The dark count signals of ~Mcps were confirmed as written in the product specification.

It seems that usage of the MPPCs for a single-photon detector

is too hard!Several tens of photons are

required.

Page 22: Development of an  Aerogel  Cherenkov Counter for the J-PARC E16 Upgrade

22

Page 23: Development of an  Aerogel  Cherenkov Counter for the J-PARC E16 Upgrade

23

Vector Meson, fJ.D.Jackson, Nuovo Cimento 34, 1644 (1964).

3* *0 0 0

*2 2

2 20 0

/

4

4

K

K

q q m m

q m m

q m m

G G

mf が変化

3*0 0

2 * 20

2 20 0

/

4

4

K

K

q q

q m m

q m m

G G

mK が変化

f mass

K mass

G*/G

0G

*/G0

Page 24: Development of an  Aerogel  Cherenkov Counter for the J-PARC E16 Upgrade

24

f Puzzle

theoretical predictions− D.Lissauer and V.Shuryak, PLB253,15(1991).

− P.-Z. Bi and J.Rafelski, PLB262,485(1991).

− J.P.Blaziot and R.M.Galain, PLB271,32(1991).

− etc.

G*(fKK)/G*(fll) の増加

G*(fKK)/G*(fll) の減少

G*(fKK)/G*(fll) の増加

PLB262,485(1991).

G*(fll)/G0(fll)

density (rCR/r0)

核物質中での f または K のスペクトラル関数の変化によって、 fll/KK の崩壊幅が変化するのではないか ?

J.Phys.G27,355(2001).

mt-m0 (GeV)

dN/m

tDyd

mt

fK+K-

fm+m-

NA49/NA50@CERN-SPS– PLB491,59(2000).; PLB555,147(2003).;

J.Phys,G27,355(2001).– fK+K-/m+m-, 158AGeV Pb+Pb– production CS’s are inconsistent

NA49/NA50

Page 25: Development of an  Aerogel  Cherenkov Counter for the J-PARC E16 Upgrade

25

f Meson MeasurementsCERES(NA45)@CERN-SPS– PRL96,152301(2006).– fe+e-/K+K-, 158AGeV Pb+Au– production CS’s are consistentPHENIX@BNL-RHIC– EPJ,A31,836(2007).– fe+e-/K+K-, sqrt(sNN)=200GeV Au+Au– production CS’s are consistentNA60@CERN-SPS– NPA830,753c(2009).– fm+m-/K+K-, 158AGeV In+In– production CS’s are consistent

Hot Matter

Cold Matter

CERES

E325@KEK-PS– PRL98, 152302(2007).– f e+e-/K+K-, 12GeV p+C/Cu

NA60

PRL96,152301(2006).

NPA830,753c(2009).