1 1 Developing an Appropriate Design Developing an Appropriate Design Space Strategy to Mitigate Variability in Space Strategy to Mitigate Variability in Downstream Processing Operations Downstream Processing Operations Justin McCue Biogen Idec Corporation September, 2010

Developing an Appropriate Design Space Strategy to ... · PDF file3 3 General Chromatography Column Scale Up Approach • Bed height constant during scale up • Scale up by increasing

  • Upload
    lamthuy

  • View
    218

  • Download
    5

Embed Size (px)

Citation preview

Page 1: Developing an Appropriate Design Space Strategy to ... · PDF file3 3 General Chromatography Column Scale Up Approach • Bed height constant during scale up • Scale up by increasing

1

1

Developing an Appropriate Design Developing an Appropriate Design Space Strategy to Mitigate Variability in Space Strategy to Mitigate Variability in

Downstream Processing OperationsDownstream Processing Operations

Justin McCue

Biogen Idec Corporation

September, 2010

Page 2: Developing an Appropriate Design Space Strategy to ... · PDF file3 3 General Chromatography Column Scale Up Approach • Bed height constant during scale up • Scale up by increasing

2

OverviewOverview

• Chromatography column scale up approach – Scale up considerations and challenges

• Chromatography Adsorbent Lot Variability– Two case studies

• HIC- Monomer/Aggregate Separation • Anion Exchange-Product-related Impurity Separation

• Design Space Approach – Ways to control adsorbent lot variability through QBD

• Conclusions and acknowledgements

Page 3: Developing an Appropriate Design Space Strategy to ... · PDF file3 3 General Chromatography Column Scale Up Approach • Bed height constant during scale up • Scale up by increasing

3

3

General Chromatography Column Scale Up ApproachGeneral Chromatography Column Scale Up Approach

• Bed height constant during scale up• Scale up by increasing column diameter and volumetric flow rate

– Development scale to cGMP scale: ~10,000x Volumetric Scale up factor

100x

Scale Up

Development Scale Pilot Scale MFG Scale

1 cm column diameter

10 cm column diameter

100 cm column diameter

100x

Scale up

Bed Height held constant

Page 4: Developing an Appropriate Design Space Strategy to ... · PDF file3 3 General Chromatography Column Scale Up Approach • Bed height constant during scale up • Scale up by increasing

4

4

Scale Up Challenges with Adsorbent Lot VariabilityScale Up Challenges with Adsorbent Lot Variability

• Different lots may need to be used across scales– Multiple lots/lot mixtures may be required to

pack a large scale column

• If adsorbent lot variability exists, risk that column performance/product quality could change during scale up

Page 5: Developing an Appropriate Design Space Strategy to ... · PDF file3 3 General Chromatography Column Scale Up Approach • Bed height constant during scale up • Scale up by increasing

5

5

Case StudiesCase Studies

• Case Study #1– HIC (Phenyl Sepharose FF) adsorbent lot variability

• Differences in yield and aggregate removal using different adsorbent lots

• Case Study #2– Anion Exchange adsorbent lot variability

• Differences in yield and removal of process-related impurity species during column wash step

Page 6: Developing an Appropriate Design Space Strategy to ... · PDF file3 3 General Chromatography Column Scale Up Approach • Bed height constant during scale up • Scale up by increasing

6

6

Case Study #1Case Study #1

HIC Adsorbent Lot variabilityHIC Adsorbent Lot variability

Page 7: Developing an Appropriate Design Space Strategy to ... · PDF file3 3 General Chromatography Column Scale Up Approach • Bed height constant during scale up • Scale up by increasing

7

Motivation for StudyMotivation for Study– HIC commonly used to separate monomer and aggregate

species for protein therapeutics (monoclonal antibodies, fusion proteins)

– HIC adsorbent (Phenyl Sepharose FF) – must reduce aggregate levels from 10−20% to < 1%

• Difficult separation – Column yields limited to <70%– Superior adsorbent for this particular separation

• Separation sensitive to column residence time (operating velocity, bed height) and column loading

Column performance sensitive to adsorbent lot (ligand density)

Page 8: Developing an Appropriate Design Space Strategy to ... · PDF file3 3 General Chromatography Column Scale Up Approach • Bed height constant during scale up • Scale up by increasing

8

• Similar elution profile for lots having lower ligand densities– Ligand density of 40 and 42 μmole/mL Similar elution peak profiles

• Smaller elution peaks when adsorbent ligand density was increased to 45−47 μmole/mL– Suggests product yield (and maybe purity) could be different when

using adsorbent lots containing higher ligand densities

Experimental Finding: Lot to lot Performance Experimental Finding: Lot to lot Performance VariabilityVariability

Development Data: Column Elution Profiles for Different adsorbent Lots

0

200

400

600

800

1000

0 2 4 6 8 10

Elution Column Volumes

UV

Abs

orba

nce

40

42

45

47

adsorbent Ligand Density (μmole/mL)

0

200

400

600

800

1000

0 2 4 6 8 10

Elution Column Volumes

UV

Abs

orba

nce

42

45

47

adsorbent Ligand Density (μmole/mL)

Isocratic Elution Condition #1 Isocratic Elution Condition #2

Page 9: Developing an Appropriate Design Space Strategy to ... · PDF file3 3 General Chromatography Column Scale Up Approach • Bed height constant during scale up • Scale up by increasing

9

30

35

40

45

50

55

60

65

70

75

39 40 41 42 43 44 45 46 47 48

Ligand Density (umole/mL resin)

Col

umn

Yiel

d (%

)

Similar Yields

• Downward trend of yield with higher ligand densities– Lot to lot variability

Use modeling insights to evaluate impact of adsorbent lot variability prior to scale up

Potential Scale Up Challenge: Lot to lot Potential Scale Up Challenge: Lot to lot Performance VariabilityPerformance Variability

Lower Yields

Development Data: Column yields for Different adsorbent Lots (Isocratic elution conditions)

Page 10: Developing an Appropriate Design Space Strategy to ... · PDF file3 3 General Chromatography Column Scale Up Approach • Bed height constant during scale up • Scale up by increasing

10

• Formulate mechanistic model to predict Monomer/Aggregate separation over range of column operating conditions– Determine governing separation performance

parameters– Predictive tool

• Understand mechanism responsible for lot-to-lot variability in performance – Apply model to evaluate acceptable operating conditions

prior to scale up– Developing a “use test” to aid in adsorbent screening

and potential design space prior to scale up

Modeling to Assist in Process ScaleModeling to Assist in Process Scale--Up Up

Page 11: Developing an Appropriate Design Space Strategy to ... · PDF file3 3 General Chromatography Column Scale Up Approach • Bed height constant during scale up • Scale up by increasing

11

Adsorption of Monomer/Aggregate SpeciesAdsorption of Monomer/Aggregate Species

• Aggregate species binds irreversibly to the HIC adsorbent– Irreversible term included in the Adsorption Isotherm Model

Phenyl Sepharose Adsorbent Surface (Solid Phase)

k1,ad

Monomer Species (C1)

k-1,de

Aggregate Species (C2)

k2,ad k-2,de

k2,irrev

Irreversibly bound

aggregate

Q1 Q2 Q2, Irr

C1 C2

Competitive Langmuir Isotherm model with irreversible binding of aggregate species1

1J.T. McCue, et al., Bioprocess and Biosystems Engineering, 31 (2008) 261.

Page 12: Developing an Appropriate Design Space Strategy to ... · PDF file3 3 General Chromatography Column Scale Up Approach • Bed height constant during scale up • Scale up by increasing

12

0

10

20

30

40

50

60

70

80

90

100

39 40 41 42 43 44 45 46 47 48Ligand Density (μmole/mL resin)

Col

umn

Yiel

d (%

)

0

1

2

3

4

5

6

7

Bin

ding

Con

stan

t (K

)

• Able to distinguish lots containing different ligand densities using an alternative test (Binding Constant from Adsorption isotherms)

Similar Yields (“Acceptable Lots”)

Similar Binding Constants

Lower Yields (“Unacceptable Lots”)

Higher Binding Constants

Correlation between Binding constant and Column Performance

K ~ 2Acceptable (K < 2) (similar yields)

Not Acceptable (K > 2) (low yields)

Page 13: Developing an Appropriate Design Space Strategy to ... · PDF file3 3 General Chromatography Column Scale Up Approach • Bed height constant during scale up • Scale up by increasing

13

• Can we use the model to determine acceptable operating conditions if the adsorbent lot or lot mixture is outside the “acceptable” range?

Further Model Applications: What happens if we are not able to “Cherry Pick” adsorbent lots?

Page 14: Developing an Appropriate Design Space Strategy to ... · PDF file3 3 General Chromatography Column Scale Up Approach • Bed height constant during scale up • Scale up by increasing

14

Effect of Higher adsorbent Ligand Density: Experimental DataEffect of Higher adsorbent Ligand Density: Experimental Data

• Using adsorbent lots with lower ligand density levels will increase aggregates above acceptable levels (e.g. 0.35 M Ammonium Sulfate, < 2.0% Aggregate)

Feed: 20 % aggregate

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

0.30 0.35 0.40 0.45 0.50Ammonium Sulfate Eluate Buffer Concentration (mM)

Agg

greg

ate

(%)

40

42

45

47

LIgand Density (μmole/mL)

Aggregates too high!

Page 15: Developing an Appropriate Design Space Strategy to ... · PDF file3 3 General Chromatography Column Scale Up Approach • Bed height constant during scale up • Scale up by increasing

15

• Change of operating conditions will be required (increase Ammonium Sulfate concentration from 0.35 to 0.45 M)

Feed: 20 % aggregate

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

0.30 0.35 0.40 0.45 0.50Ammonium Sulfate Eluate Buffer Concentration (mM)

Agg

greg

ate

(%)

40

42

45

47

LIgand Density (μmole/mL)

Effect of Higher adsorbent Ligand Density: Experimental DataEffect of Higher adsorbent Ligand Density: Experimental Data

Page 16: Developing an Appropriate Design Space Strategy to ... · PDF file3 3 General Chromatography Column Scale Up Approach • Bed height constant during scale up • Scale up by increasing

16

0.25

0.30

0.35

0.40

0.45

0.50

35 37 39 41 43 45 47 49

ligand density [umol \ mL]

amm

omiu

m s

ulfa

te [M

]aggragte [%] yield [%] 1.6 46

2.0 50

2.5 58

3.0 62 4.0 70

• Model used to predict acceptable operating conditions• For a ligand density of 47 μmole/mL, aggregate levels will be 2.0% and

product yields 50% if Ammonium sulfate concentration in the elution buffer is 0.29 M

Modeling Predictions to Guide Scale UpModeling Predictions to Guide Scale Up

Feed: 20% Aggregate

Page 17: Developing an Appropriate Design Space Strategy to ... · PDF file3 3 General Chromatography Column Scale Up Approach • Bed height constant during scale up • Scale up by increasing

17

0.25

0.30

0.35

0.40

0.45

0.50

35 37 39 41 43 45 47 49

ligand density [umol \ mL]

amm

omiu

m s

ulfa

te [M

]aggragte [%] yield [%] 1.6 46

2.0 50

2.5 58

3.0 62 4.0 70

• Similar product purity and yield achievable for lower ligand density lots (42 μmole/mL) if AS concentration increased from 0.29 M to 0.41 M AS

Modeling Predictions to Guide Scale UpModeling Predictions to Guide Scale Up

Feed: 20% Aggregate

Page 18: Developing an Appropriate Design Space Strategy to ... · PDF file3 3 General Chromatography Column Scale Up Approach • Bed height constant during scale up • Scale up by increasing

18

• Mechanistic model provides additional insight on separation performance prior to scale up – Determine most sensitive (governing) input

parameters – Useful for predicting performance of the unit

operation outside the range explored during development

– Developed a protein-specific use test to assist in screening adsorbent lots

• Model applied to predict acceptable conditions for different adsorbent ligand density levels– Useful if selection of adsorbent lots with specific

ligand densities is not possible

Mechanistic Modeling to Guide Process Scale up for Adsorbent Variability

Page 19: Developing an Appropriate Design Space Strategy to ... · PDF file3 3 General Chromatography Column Scale Up Approach • Bed height constant during scale up • Scale up by increasing

19

Model Case Study #2Model Case Study #2

Anion Exchange Adsorbent Lot variabilityAnion Exchange Adsorbent Lot variability

Page 20: Developing an Appropriate Design Space Strategy to ... · PDF file3 3 General Chromatography Column Scale Up Approach • Bed height constant during scale up • Scale up by increasing

20

Background for Case Study #2Background for Case Study #2

• Anion exchange column performed in the “bind/elute” mode• Main function of column

– Removal of a product-related impurity species in wash step (prior to product elution)

• Desirable to have 5-10% product loss in wash to ensure the product-related impurity is effectively removed

• Difficult separation due to similarities between the product-related impurities and target product – Column performance sensitive to changes in column

loading and wash buffer composition (pH, Osmolality)• Significant adsorbent lot variability

Page 21: Developing an Appropriate Design Space Strategy to ... · PDF file3 3 General Chromatography Column Scale Up Approach • Bed height constant during scale up • Scale up by increasing

21

Adsorbent Lot Variability During Wash StepAdsorbent Lot Variability During Wash Step

• Increase in protein loss during wash step for adsorbents lots containing higher Ionic Capacity – Some resin lots which did not follow the trend

Protein Loss During Wash Step for Different Adsorbent Lots1

1Cecchini, D.; Quality by Design for Biopharmaceuticals, 2009, P. 140

Page 22: Developing an Appropriate Design Space Strategy to ... · PDF file3 3 General Chromatography Column Scale Up Approach • Bed height constant during scale up • Scale up by increasing

22

Adsorbent Lot Variability During Wash StepAdsorbent Lot Variability During Wash Step

• Increase in protein loss during wash step for adsorbents lots containing higher Ionic Capacity – Some resin lots which did not follow the trend

• May require an additional correlation beyond one provided on the COA or by the Vendor

Protein Loss During Wash Step for Different Adsorbent Lots1

1Cecchini, D.; Quality by Design for Biopharmaceuticals, 2009, P. 140

Page 23: Developing an Appropriate Design Space Strategy to ... · PDF file3 3 General Chromatography Column Scale Up Approach • Bed height constant during scale up • Scale up by increasing

23

• Lot to lot variability measured during protein adsorption isotherm experiments using the wash buffer conditions

• Measure the binding constant (KL) for each of the adsorbent lots

Adsorption Isotherms for Different Adsorbent LotsAdsorption Isotherms for Different Adsorbent Lots

0

5

10

15

20

25

30

0.0 0.5 1.0 1.5 2.0CF (mg/mL)

q (m

g pr

otei

n/m

L re

sin)

99 μeq/mL

153 μeq/mL

150 μeq/mL

131 μeq/mL

Adsorbent Ionic Capacity

Liquid Phase: Column Wash Buffer

q = KL*C

Page 24: Developing an Appropriate Design Space Strategy to ... · PDF file3 3 General Chromatography Column Scale Up Approach • Bed height constant during scale up • Scale up by increasing

24

• Correlation between binding constant and column performance– Process-specific use test can be used to detect differences in adsorbent

lot performance

ProcessProcess--Specific Adsorbent Use TestSpecific Adsorbent Use Test

y = -2.0007x + 39.525R2 = 0.9376

0

2

4

6

8

10

12

14

16

10 12 14 16 18 20

Binding Constant (KL)

Prot

ein

Loss

dur

ing

Was

h (%

)

Correlation between Protein Loss (in Wash step) and Binding Constant for different Adsorbent Lots

Page 25: Developing an Appropriate Design Space Strategy to ... · PDF file3 3 General Chromatography Column Scale Up Approach • Bed height constant during scale up • Scale up by increasing

25

• How do we control differences in lot variability during GMP MFG?– Potential impacts on both process consistency and product quality

• Several Approaches Exist– Conventional Approach

• Select operating conditions/range in which all adsorbent lots will have acceptable performance

• May result in sub-optimal process performance – “Cherry pick” Approach

• Use only certain adsorbent lots in MFG processing • May or may not be possible• Not desirable

– Design Space/QBD Approach • Design space filing which includes ranges in column operating

conditions • Can control adsorbent lot variability through changes in the

column operating conditions

Manufacturing Process Control ConsiderationsManufacturing Process Control Considerations

Page 26: Developing an Appropriate Design Space Strategy to ... · PDF file3 3 General Chromatography Column Scale Up Approach • Bed height constant during scale up • Scale up by increasing

26

• Change the wash buffer composition to achieve the appropriate level of product removal during the wash step

• Provides flexibility in managing different adsorbent lots– Potential impacts on both process consistency and product quality

Design Space Approach for Anion ExchangeDesign Space Approach for Anion ExchangeEffect of Wash Buffer pH and NaCl

Concentration on Product Loss in Wash

x

x

Adsorbent Lot “A”

Page 27: Developing an Appropriate Design Space Strategy to ... · PDF file3 3 General Chromatography Column Scale Up Approach • Bed height constant during scale up • Scale up by increasing

27

0.25

0.30

0.35

0.40

0.45

0.50

35 37 39 41 43 45 47 49

ligand density [umol \ mL]

amm

omiu

m s

ulfa

te [M

]aggragte [%] yield [%] 1.6 46

2.0 50

2.5 58

3.0 62 4.0 70

• Change the Elution Buffer Ammonium Sulfate concentration to achieve consistent product quality and yield for different adsorbent lots

Feed: 20% Aggregate

Design Space Approach for HICDesign Space Approach for HIC

Page 28: Developing an Appropriate Design Space Strategy to ... · PDF file3 3 General Chromatography Column Scale Up Approach • Bed height constant during scale up • Scale up by increasing

28

0.25

0.30

0.35

0.40

0.45

0.50

35 37 39 41 43 45 47 49

ligand density [umol \ mL]

amm

omiu

m s

ulfa

te [M

]aggragte [%] yield [%] 1.6 46

2.0 50

2.5 58

3.0 62 4.0 70

Feed: 20% Aggregate

• QBD filing can include ranges for elution buffer composition – Selection of the elution buffer composition can be based upon the

adsorbent lot binding constant• Provides additional process control to ensure consistent and optimal

process performance

Design Space Approach for HICDesign Space Approach for HIC

Page 29: Developing an Appropriate Design Space Strategy to ... · PDF file3 3 General Chromatography Column Scale Up Approach • Bed height constant during scale up • Scale up by increasing

29

ConclusionsConclusions• Adsorbent lot variability should be evaluated, especially when

performing difficult separations – Illustrated with two case studies: HIC and Anion Exchange

columns– Formulated a mechanistic model useful as a predictive tool

• Adsorbent CoA information can be helpful, but a process/product specific use test may be required to correlate adsorbent lot variability with process performance– Measurement of adsorption isotherm binding constants-useful

to detect difference among adsorbent lots

• Flexibility in selecting elution or wash buffer composition to provide optimal process performance– Design Space/QBD Filing strategy could be used to implement

this approach in drug substance manufacturing

Page 30: Developing an Appropriate Design Space Strategy to ... · PDF file3 3 General Chromatography Column Scale Up Approach • Bed height constant during scale up • Scale up by increasing

30

30

AcknowledgementsAcknowledgements

• Philip Engel• Austen Ng• Rich Macniven• Jason Dube

Page 31: Developing an Appropriate Design Space Strategy to ... · PDF file3 3 General Chromatography Column Scale Up Approach • Bed height constant during scale up • Scale up by increasing

31

31

ReferencesReferences

• Phenyl Sepharose Modeling and Adsorbent Lot variability across scales– J.T. McCue, P. Engel, A. Ng, R. Macniven, J. Thömmes,

“Modeling of Protein Monomer/Aggregate Purification and Separation Using Hydrophobic Interaction Chromatography,”Bioprocess and Biosystems Engineering, 31 (2008) 261.

– J.T. McCue, P. Engel, J. Thömmes, “Effect of Phenyl Sepharose Ligand Density on Protein Monomer/Aggregate Purification and Separation Using Hydrophobic Interaction Chromatography,”Journal of Chromatography A, 1216 (2009) 902.

– J.T. McCue, P. Engel, J. Thömmes, “Modeling the Effects of Column Packing Quality and Residence Time Changes on Protein Monomer/Aggregate Separation,” Journal of Chromatography A, 1216 (2009) 4895.