2 A-dec Sterilization and Material Management Solutions
The heart of your practice.Patient protection goes beyond processes and protocols. It’s about purpose and place to expedite materials management and streamline workflow. It considers durability to withstand wet, harsh dental environments. And it helps ensure compliance by intuitively and safely guiding the dental team through the sterilization process. That’s a big ask. But with more than five decades in the dental industry, thoughtful design based on the way dental teams practice is second nature to A-dec.
Now we’ve taken the sterilization center one step further with modular, exponentially configurable units that stop and start where needed, and adapt to any floorplan—large, small or irregular. When it comes down to it, the sterilization center may be called the heart of the practice, but people are the heart of the dental industry. And nothing is more important than protecting you and your patients.
3A-dec Sterilization and Material Management Solutions A-dec Sterilization and Material Management Solutions
4 A-dec Sterilization and Material Management Solutions
STERILIZATION FRONT AND CENTER.As infection control becomes increasingly more public, the sterilization center is no longer something to hide away in the back room. Many patients are requesting a tour as they visit prospective offices. While they may not be experts in infection control, savvy patients can tell the difference between a well-organized, hygienic process and one that may expose them to unwanted hazards.
When materials move efficiently, so do you. A-dec sterilization centers are organized into functional workspaces, with specified areas for receiving, cleaning, preparation, packaging, sterilization and storage. You can easily group together related steps and simplify the entire sterilization process. The furniture design follows recommended CDC protocol, creating a safe, consistent process and streamlining the flow of materials: Load materials and instruments directly from the sterilization center or sterilized storage, deliver them to the treatment room, and return used materials for processing. Everything is in position and ready when you are, optimizing labor—one of your highest costs.
5A-dec Sterilization and Material Management Solutions A-dec Sterilization and Material Management Solutions
Create a safer, more efficient environment.
6 A-dec Sterilization and Material Management Solutions
RECEIVE INSTRUMENTSIn this high-turnover area, an orderly design with a clearly defined entry and exit helps streamline instrument flow and increase efficiency. Designated spaces for dirty instruments eliminate clutter when you’re in a hurry.
PROTECT OPERATORSRed infill indicates contaminated. Blue indicates clean. With visual cues and separate storage spaces, dental workers decrease the chance of cross contamination or accidental exposure to microorganisms and contaminants.
MANAGE WASTEDesignated containers allow the dental team to safely separate sharps, biowaste and trash, simplifying waste management and adherence to safety guidelines.
[1]
[5]
[2]
[6][3]
[7]
[4]
[8]
7A-dec Sterilization and Material Management Solutions A-dec Sterilization and Material Management Solutions
REDUCE TOUCHPOINTSWhen you’re too busy to begin processing right away, the foot-activated upper receiving area stores the dirty materials and keeps the sterilization area clutter free.
KEEP IT HANDS FREEUse the convenient foot control to access the upper storage compartment while holding trays of soiled instruments.
REDUCE CONTAMINATIONA safe distance between the temporary receiving area and countertop gives you plently of space to work.
KEEP IT CLEAR Strategically located holders keep appropriate gloves within reach for sterilization tasks.
CHOOSE SAFETYConveniently access and store puncture- and chemical-resistant utility gloves.
DISPOSE SHARPSForget to dispose sharps in the treatment room? No worries. The out-of-sight backup container is there when you need it.
SEPARATE WASTE Strategically located waste drop containers separate sharps and biowaste from trash for proper disposal. Hands-free activation.
Scal
abili
ty &
Ca
pact
iy
ACTIVATE HANDS FREE Motion-activated soap dispenser eliminates one more touchpoint, reducing the risk of cross contamination.
RECEIVING UPPER
OPTIONS:
28” Auto (hands-free) opening
14” Manual opening
28” Manual opening
MATCHING FLEXIBILITY
If you don’t want red or blue infills, you can select one that matches your other cabinetry. The choice is yours.
[1]
[5]
[2]
[6]
[3]
[7]
[4]
[8]
8 A-dec Sterilization and Material Management Solutions
PRESOAKWhen instruments can’t be processed right away, you need a designated place to store them—and cluttering up the countertop isn’t it. Pre-soak drawers keep bioburden from drying until you can complete the cycle.
CLEANCleaning is one of the most critical steps in reprocessing instruments. Clearly designated zones keep dirty instruments and materials from contaminating other areas of the sterilization center.
RINSEThe space to adequately rinse cassettes, baskets or oversized items without splashing is key to this important step in completing the cleaning process.
[6]
[2]
[5][3] [7]
[4]
[1]
9A-dec Sterilization and Material Management Solutions A-dec Sterilization and Material Management Solutions
INHIBIT BIOBURDENSpecially designed injection molded pre-soak drawers hold contaminated instruments and prevent bioburden from drying as they wait for reprocessing.
PREVENT DAMAGESpill-resistant pre-soak drawers hold enzymatic cleaning solution to prevent instrument damage. Stainless steel transfer baskets expedite the transfer process.
BE FLEXIBLEReceiving modules accommodate various sizes and brands of automated cleaning devices, ultrasonic cleaners, instrument washers and handpiece maintenance devices.
GET COMFORTABLEAccessible, lowered tabletop modules feel just right to comfortably unload tabletop ultrasonic cleaners.
Scal
abili
ty &
Ca
pact
iy
DUAL SINKS
Two separate 594 configurations offer flexibility if you need more than one sink.
SPACE SAVING
24” or 28” module holds recessed ultrasonic cleaners.
ADDITIONAL ULTRASONICS
There is space to add additional ultrasonic cleaning modules for larger or growing dental practices and clinics, 24” or 28”.
[2]
[3]
[1]
[4]
RINSE SMARTPull-down faucet rinses instruments with stream or spray. It’s activated by the foot pedal, so your hands can remain free for cleaning and rinsing.
REMOVE EXCESS WATERAir syringe removes excess water and debris from outside and inside hollow instruments and handpieces.
CLEAN UP FASTHigh-volume evacuator (HVE) cleans up spills and removes liquids from surfaces and presoak drawers.
[5] [6] [7]
10 A-dec Sterilization and Material Management Solutions
LUBRICATE AND FLUSHAs reusable medical devices, handpieces undergo extensive reprocessing after every use. If the sterilization center isn’t well organized and sequential, the entire cycle bottlenecks… and the waiting begins.
DRYEfficiently prep and dry the next load of instruments while the sterilizer is running to keep the process moving.
PACKAGEOrganized supplies and strategically located supply drawers expedite the packaging process.
[1]
[5]
[2][6]
[3]
[7]
[8]
[4]
11A-dec Sterilization and Material Management Solutions A-dec Sterilization and Material Management Solutions
DRY INSTRUMENTSBuilt-in dryer ensures that instruments are thoroughly dry before going into the autoclave, for the longevity of both.
INCREASE WORKSPACE Space at a premium? Configure wrapping drawers below the sterilizer for an added surface (approximately four square feet).
ELIMINATE SECOND GUESSINGBuilt-in dryer includes an On/Off motion sensor above the counter. An indicator light signals when the dryer is active, so there’s no second-guessing if there’s a cycle in progress.
ADD COLOR-CODED CONFIDENCEAssign a color for each procedure and these tray inserts allow you to create a streamlined, stress-free routine from setup to sterilization.
EASE EYESTRAINAccurate LED task lighting is easy on the eyes as you inspect instruments prior to bagging or wrapping.
Scal
abili
ty &
Ca
pact
iy
SMALL SPACE SINK
Smaller, more shallow sink increases flexibility in smaller floor plans. Add a large utility glove holder and small waste container to keep it tidy.
10” INSTRUMENT DRYER
Configure the locaton where it’s most convenient within your workflow. Dryer cycle time is less than sterilizer time, which can minimize handoff inefficiencies.
FLEXIBILITY THAT FITS
Add 14” storage and trash drop modules, or up to 112” in single-height countertops.
[5]
[8][6]
[4]
[7]
PROTECT YOUR INVESTMENT
The Assistina Twin automatically and precisely lubricates internal components and removes debris, reducing friction and extending handpiece life.
DECREASE WAIT TIMETen-second cycle time and dual independent alternating chambers allow nonstop loading and fast processing: up to 360 instruments per hour.
MINIMIZE CONSUMPTIONThe Assistina Twin only takes one consumable kit (compared to 20 handheld spray cans) to maintain 2,850 instruments. It’s easy to install and easy on the environment.
[1] [2] [3]
12 A-dec Sterilization and Material Management Solutions
STERILIZEDental instruments are potential agents for pathogenic transmission from patient-to-patient, patient-to-doctor (and vice versa), placing dental health professionals on the front line of the war against infection. That means the processes you follow and equipment you use to sterilize instruments are critical tools in protecting patients and staff alike. As the most essential step in the reprocessing cycle, sterilization also takes the longest to complete. But with an efficient, systematic sterilization center, you can maintain a safe and healthy practice--and save valuable time.
[1]
[5]
[2]
[6]
[3]
[7]
[8]
[4]
13A-dec Sterilization and Material Management Solutions A-dec Sterilization and Material Management Solutions
FEEL CONFIDENTThe Lexa sterilizer uses closed-door vacuum drying coupled with steam condensing vacuum technology to produce bone-dry loads.
RELIEVE BOTTLENECKSLexa’s 11” chamber holds four large trays and up to four levels of cassettes, so you can sterilize and dry 18 lbs. of dental instruments in as little as 30 minutes.
PREVENT STEAM DAMAGEDesigned for the dental environment, a metal upper cabinet base wards off blasts of steam and prevents moisture damage.
STREAMLINE FLOWDrawer inserts come in many configurations to streamline the storage and flow of sterilized materials.
GAIN CAPACITYLexa’s universal 3-in-1 rack offers flexibility: Place pouches on four large trays and up to four levels of cassettes (including surgical and double-decker), vertically and horizontally.
CONTAIN SPILLSIntegrated, slide-out waterproof shelf is engineered to accommodate cassette-style autoclaves and protect the cabinet and floor from potential liquid spills.
IMPROVE TRACEABILITY Connect the optional label printer and automatically print and attach bar code labels to every load, in compliance with CDC package labeling requirements.
SLIDE OUT FOR CONVENIENCESlide-out shelf is engineered specifically to bear the sterilizer’s weight and protect the cabinet and floor from spills and moisture.
Scal
abili
ty &
Ca
pact
iy
LOCATION DIVIDERS
Add storage towers between sterilization areas to divide and organize.
AESTHETICS
Match your other cabinet infills, or choose blue with an aluminum frame door to visually designate clean.
MULTIPLE TOWERS
The option to add up to 15 modules per configuration lets you have a smooth and efficient sterilization process regardless of practice size.
[1]
[5]
[2]
[6]
[3]
[7] [8]
[4]
14 A-dec Sterilization and Material Management Solutions
STORE AND STAGEYour materials and instruments are properly sterilized. Now keep them safe in storage that protects instrument packages from tears, punctures, water splashes and moisture.
MANAGE MATERIALSPlanning and controlling the flow of materials and supplies is critical to the successful daily operation of a practice. Decades in the dental industry have taught us the intricate details and time-saving organizational tricks that keep everything in place and encourage adherence to process and protocol.
You’ll see them here.
[1]
[5]
[6]
[2]
[8]
[3]
[7]
[4]
15A-dec Sterilization and Material Management Solutions A-dec Sterilization and Material Management Solutions
CUSTOMIZE STORAGE Every office is different, and our modular concept allows the dental team to organize materials to reflect workflow.
REMOVE AND RESTOCKOrganize. Reorganize. Remove. Clean. Clear removable bins make it easy to manage supplies at a glance.
TILT-OUT BINSClear, tilt-out bins make it easy to see what’s inside, while keeping supplies safely enclosed.
REPOSITION ACCORDINGLY Easily moveable wire instrument storage racks accommodate large trays and cassettes.
CHANGE YOUR MIND Your materials belong in a box, not you. These completely customizable bins let you arrange--and rearrange—just the way you like.
ORGANIZE CONFIDENTLYMaximum visibility means you can find what you need quickly, and efficiently move on.
PREP TUBS AND TRAYSCustomizable bins in the make-ready station neatly hold items to prep trays and tubs for procedures. So set up and restocking is orderly and intuitive.
CUSTOMIZE DRAWERS Divided sections and flexible organizer bin arrangement let you customize a productive set up for your practice.
Scal
abili
ty &
Ca
pact
iy
START AND STOP
FLEXIBILITY
Sometimes space (or budget) requires a different sterilization configuration. A-dec’s modular design grants the flexibility to create a system that works for you.
MULTIPLE TOWERS
Regardless of practice size, the customizable make-ready option adds efficient access and imporoved inventory control over materials management.
[1]
[5]
[2]
[6]
[3]
[7] [8]
[4]
16 A-dec Sterilization and Material Management Solutions
COLOR-MATCHED TASK LIGHTING
Integrated, accurate LED task lighting softly illuminates the countertop while you work. Energy efficient and color matched to A-dec LED dental lights.
MOISTURE-RESISTANT SHELVING
Sturdy, slide-out waterproof shelves hold automated cleaning equipment and include a channel to contain spills and simplify removal of liquids.
ABUSE RESISTANT
Designed for the dental environment, the powder-coated handles won’t wear or tarnish over the life of the product.
SMARTLY ORGANIZED
Instrument storage racks are shaped to accommodate large trays and cassettes. (They’re also durable, simple to remove, and easy to clean.)
CREATED FOR DENTISTRY. MADE FOR THE DENTAL ENVIRONMENT.
17A-dec Sterilization and Material Management Solutions A-dec Sterilization and Material Management Solutions
ROBUST AND LONG LASTING
Heavy-duty cam lock fasteners, 2mm PVC edgebanding, melamine interior surfaces, and high-strength European hinges all add up to maximized cabinet life and long-term value.
RIGOROUSLY TESTED
Surface and cabinetry materials are chemically safe and scrupulously tested to withstand the inherently harsh sterilization center processes.
CORROSION-FREE FOUNDATION
The heavy-gauge steel subbase is pretreated with a polyester powder-coat finish that protects against rust and corrosion. The subbase is removable for leveling and access.
CREATED FOR DENTISTRY. MADE FOR THE DENTAL ENVIRONMENT.
18 A-dec Sterilization and Material Management Solutions
WITH FLEXIBILITY LIKE THIS, there’s no such thing as an obstacle. The modular design of the 594b series gives you the freedom to stop, start and build around whatever pole, pillar or wall you run into.
It’s a new level of flexibility.
L C 01/19
VACUUM
DRAIN
5/8" O.D. (16 mm) TubingFor Central Vacuum Only(see General Utility Notes)
Optional2" DATACONDUIT(locate as needed)
1-1/2" (38 mm) NominalPipe For Gravity Drain(when required)
WATER
AIR
Hospital-G
rade Quad Electrical
Box Supplied by Contractor
(check amperage requirem
ents)
ELECTRICAL
L C 01/19
VACUUM
DRAIN
5/8" O.D. (16 mm) TubingFor Central Vacuum Only(see General Utility Notes)
Optional2" DATACONDUIT(locate as needed)
1-1/2" (38 mm) NominalPipe For Gravity Drain(when required)
WATER
AIR
Hospital-G
rade Quad Electrical
Box Supplied by Contractor
(check amperage requirem
ents)
ELECTRICAL
Air
ElectricalOptional
Power Distribution BoxLocate as needed
QUAD ELECTRICAL BOXSupplied by A-dec(check amperagerequirements)
Locate as neededDrain
ColdWater
HotWater
Optional UtilityChase
Optional UtilityChase
03/16
Air
HotWater
ColdWater
OptionalLoopVent
Drain
Electrical
Optional Power SupplyLocate in General Area
X-RayElectrical
Power Distribution BoxLocate as needed
QUAD ELECTRICAL BOXSupplied By A-DEC(Check amperagerequirements)Locate as needed
3/4"X-Ray(lowvoltage)
Power Distribution BoxLocate as needed
Optional Utility Chase fromCabinet to Chair Utility Box
Optional Utility Chase fromCabinet to Chair Utility Box
03/16
Air
ElectricalOptional
Power Distribution BoxLocate as needed
QUAD ELECTRICAL BOXSupplied by A-dec(check amperage
requirements)Locate as needed
Drain
ColdWater
HotWater
Optional UtilityChase
Optional UtilityChase
03/16
Vacuum
ON2
O2
Air
Power Supply
(locate as needed)
Optional U
tility Chase from
12 O'C
lock to Chair U
tility Box
Power D
istribution Box(locate as needed)
Electric
al
Optional U
tility Chase for
Side or Central cabinets
Optional U
tility Chase for
Side or Central cabinets
QUAD ELECTRICAL BOX
Supplied By A-DEC
(Check amperage
requirements)
Locate as needed
3/4"
X-Ray
(low
voltage)
Optional
Utility C
hase
03/16
Vacuum
ON2
O2
Air
Power Supply
(locate as needed)
Optional U
tility Chase from
12 O'C
lock to Chair U
tility Box
Power D
istribution Box(locate as needed)
Electric
al
Optional U
tility Chase for
Side or Central cabinets
Optional U
tility Chase for
Side or Central cabinets
QUAD ELECTRICAL BOX
Supplied By A-DEC
(Check amperage
requirements)
Locate as needed
3/4"
X-Ray
(low
voltage)
Optional
Utility C
hase
03/16
14"
2218"
14"
14"
03/16
03/16
09/05
09/05
09/05
09/05
LC
01/19
VACU
UM
DR
AIN
5/8" O.D
. (16 mm
) TubingFor C
entral Vacuum O
nly(see G
eneral Utility N
otes)
Optional
2" DATA
CO
ND
UIT
(locate as needed)
1-1/2" (38 mm
) Nom
inalPipe For G
ravity Drain
(when required)
WATER
AIR
Hospital-Grade Quad ElectricalBox Supplied by Contractor(check amperage requirements)
ELECTR
ICAL
LC
01/19
VACU
UM
DR
AIN
5/8" O.D
. (16 mm
) TubingFor C
entral Vacuum O
nly(see G
eneral Utility N
otes)
Optional
2" DATA
CO
ND
UIT
(locate as needed)
1-1/2" (38 mm
) Nom
inalPipe For G
ravity Drain
(when required)
WATER
AIR
Hospital-Grade Quad ElectricalBox Supplied by Contractor(check amperage requirements)
ELECTR
ICAL
Air
Electrical
Optional
Power Distribution Box
Locate as needed
QUAD ELECTRICAL BOX
Supplied by A-dec
(check amperage
requirements)
Locate as needed
Drain
Cold
Water
Hot
Water
Optional Utility
Chase
Optional Utility
Chase
03/16
Air
Hot
Water
Cold
Water
Optional
Loop
Vent
Drain
Electric
al
Optional Pow
er SupplyLocate in G
eneral Area
X-Ray
Electric
al
Power D
istribution BoxLocate as needed
QUAD ELECTRICAL BOX
Supplied By A-DEC
(Check amperage
requirements)
Locate as needed
3/4"
X-Ray
(low
voltage)
Power D
istribution BoxLocate as needed
Optional U
tility Chase from
Cabinet to C
hair Utility Box
Optional U
tility Chase from
Cabinet to C
hair Utility Box
03/16
Air
Electrical
Optional
Pow
er D
istri
butio
n Bo
xLo
cate
as
need
ed
QUAD ELECTRICAL BOX
Supplied by A-dec
(check amperage
requirements)
Locate as needed
Drain
Cold
Water
Hot
Water
Opt
iona
l Util
ityC
hase
Opt
iona
l Util
ityC
hase
03/1
6
VacuumON2O2
Air
Power Supply(locate as needed)
Optional Utility Chase from12 O'Clock to Chair Utility Box
Power Distribution Box(locate as needed)
Electrical
Optional Utility Chase forSide or Central cabinets
Optional Utility Chase forSide or Central cabinets
QUAD ELECTRICAL BOXSupplied By A-DEC(Check amperagerequirements)
Locate as needed
3/4"X-Ray(lowvoltage)
OptionalUtility Chase
03/16
VacuumON2O2
Air
Power Supply(locate as needed)
Optional Utility Chase from12 O'Clock to Chair Utility Box
Power Distribution Box(locate as needed)
Electrical
Optional Utility Chase forSide or Central cabinets
Optional Utility Chase forSide or Central cabinets
QUAD ELECTRICAL BOXSupplied By A-DEC(Check amperagerequirements)
Locate as needed
3/4"X-Ray(lowvoltage)
OptionalUtility Chase
03/16
9"171 8"
9"
03/16
09/05
09/05
09/05
09/05
60"
L C 01/19
VACUUM
DRAIN
5/8" O.D. (16 mm) TubingFor Central Vacuum Only(see General Utility Notes)
Optional2" DATACONDUIT(locate as needed)
1-1/2" (38 mm) NominalPipe For Gravity Drain(when required)
WATER
AIR
Hospital-G
rade Quad Electrical
Box Supplied by Contractor
(check amperage requirem
ents)
ELECTRICAL
L C 01/19
VACUUM
DRAIN
5/8" O.D. (16 mm) TubingFor Central Vacuum Only(see General Utility Notes)
Optional2" DATACONDUIT(locate as needed)
1-1/2" (38 mm) NominalPipe For Gravity Drain(when required)
WATER
AIR
Hospital-G
rade Quad Electrical
Box Supplied by Contractor
(check amperage requirem
ents)
ELECTRICAL
Air
ElectricalOptional
Power Distribution BoxLocate as needed
QUAD ELECTRICAL BOXSupplied by A-dec(check amperagerequirements)
Locate as neededDrain
ColdWater
HotWater
Optional UtilityChase
Optional UtilityChase
03/16
Air
HotWater
ColdWater
OptionalLoopVent
Drain
Electrical
Optional Power SupplyLocate in General Area
X-RayElectrical
Power Distribution BoxLocate as needed
QUAD ELECTRICAL BOXSupplied By A-DEC(Check amperagerequirements)Locate as needed
3/4"X-Ray(lowvoltage)
Power Distribution BoxLocate as needed
Optional Utility Chase fromCabinet to Chair Utility Box
Optional Utility Chase fromCabinet to Chair Utility Box
03/16
Air
ElectricalOptional
Power Distribution BoxLocate as needed
QUAD ELECTRICAL BOXSupplied by A-dec(check amperagerequirements)
Locate as neededDrain
ColdWater
HotWater
Optional UtilityChase
Optional UtilityChase
03/16
Vacuum
ON2
O2
Air
Power Supply
(locate as needed)
Optional U
tility Chase from
12 O'C
lock to Chair U
tility Box
Power D
istribution Box(locate as needed)
Electric
al
Optional U
tility Chase for
Side or Central cabinets
Optional U
tility Chase for
Side or Central cabinets
QUAD ELECTRICAL BOX
Supplied By A-DEC
(Check amperage
requirements)
Locate as needed
3/4"
X-Ray
(low
voltage)
Optional
Utility C
hase
03/16
Vacuum
ON2
O2
Air
Power Supply
(locate as needed)
Optional U
tility Chase from
12 O'C
lock to Chair U
tility Box
Power D
istribution Box(locate as needed)
Electric
al
Optional U
tility Chase for
Side or Central cabinets
Optional U
tility Chase for
Side or Central cabinets
QUAD ELECTRICAL BOX
Supplied By A-DEC
(Check amperage
requirements)
Locate as needed
3/4"
X-Ray
(low
voltage)
Optional
Utility C
hase
03/16
14"
2218"
14"
14"
03/16
03/16
09/05
09/05
09/05
09/05
WORKROOM
217 8"
28"
601 8"
34"
4/02
4/02
4/02
4/02
4/02
4/02
5214"34"
4/02
5214" 577
8" 34"
651 8"
LC
01/19
VACU
UM
DR
AIN
5/8" O.D
. (16 mm
) TubingFor C
entral Vacuum O
nly(see G
eneral Utility N
otes)
Optional
2" DATA
CO
ND
UIT
(locate as needed)
1-1/2" (38 mm
) Nom
inalPipe For G
ravity Drain
(when required)
WATER
AIR
Hospital-Grade Quad ElectricalBox Supplied by Contractor(check amperage requirements)
ELECTR
ICAL
Air
Electrical
Optional
Power Distribution Box
Locate as needed
QUAD ELECTRICAL BOX
Supplied by A-dec
(check amperage
requirements)
Locate as needed
Drain
Cold
Water
Hot
Water
Optional Utility
Chase
Optional Utility
Chase
03/16
VacuumON2O2
Air
Power Supply(locate as needed)
Optional Utility Chase from12 O'Clock to Chair Utility Box
Power Distribution Box(locate as needed)
Electrical
Optional Utility Chase forSide or Central cabinets
Optional Utility Chase forSide or Central cabinets
QUAD ELECTRICAL BOXSupplied By A-DEC(Check amperagerequirements)
Locate as needed
3/4"X-Ray(lowvoltage)
OptionalUtility Chase
03/16
03/16
09/05
09/05
LC
01/19
VACU
UM
DR
AIN
5/8" O.D
. (16 mm
) TubingFor C
entral Vacuum O
nly(see G
eneral Utility N
otes)
Optional
2" DATA
CO
ND
UIT
(locate as needed)
1-1/2" (38 mm
) Nom
inalPipe For G
ravity Drain
(when required)
WATER
AIR
Hospital-Grade Quad ElectricalBox Supplied by Contractor(check amperage requirements)
ELECTR
ICAL
LC
01/19
VACU
UM
DR
AIN
5/8" O.D
. (16 mm
) TubingFor C
entral Vacuum O
nly(see G
eneral Utility N
otes)
Optional
2" DATA
CO
ND
UIT
(locate as needed)
1-1/2" (38 mm
) Nom
inalPipe For G
ravity Drain
(when required)
WATER
AIR
Hospital-Grade Quad ElectricalBox Supplied by Contractor(check amperage requirements)
ELECTR
ICAL
Air
Electrical
Optional
Power Distribution Box
Locate as needed
QUAD ELECTRICAL BOX
Supplied by A-dec
(check amperage
requirements)
Locate as needed
Drain
Cold
Water
Hot
Water
Optional Utility
Chase
Optional Utility
Chase
03/16
Air
Hot
Water
Cold
Water
Optional
Loop
Vent
Drain
Electric
al
Optional Pow
er SupplyLocate in G
eneral Area
X-Ray
Electric
al
Power D
istribution BoxLocate as needed
QUAD ELECTRICAL BOX
Supplied By A-DEC
(Check amperage
requirements)
Locate as needed
3/4"
X-Ray
(low
voltage)
Power D
istribution BoxLocate as needed
Optional U
tility Chase from
Cabinet to C
hair Utility Box
Optional U
tility Chase from
Cabinet to C
hair Utility Box
03/16
Air
Electrical
Optional
Pow
er D
istri
butio
n Bo
xLo
cate
as
need
ed
QUAD ELECTRICAL BOX
Supplied by A-dec
(check amperage
requirements)
Locate as needed
Drain
Cold
Water
Hot
Water
Opt
iona
l Util
ityC
hase
Opt
iona
l Util
ityC
hase
03/1
6
VacuumON2O2
Air
Power Supply(locate as needed)
Optional Utility Chase from12 O'Clock to Chair Utility Box
Power Distribution Box(locate as needed)
Electrical
Optional Utility Chase forSide or Central cabinets
Optional Utility Chase forSide or Central cabinets
QUAD ELECTRICAL BOXSupplied By A-DEC(Check amperagerequirements)
Locate as needed
3/4"X-Ray(lowvoltage)
OptionalUtility Chase
03/16
VacuumON2O2
Air
Power Supply(locate as needed)
Optional Utility Chase from12 O'Clock to Chair Utility Box
Power Distribution Box(locate as needed)
Electrical
Optional Utility Chase forSide or Central cabinets
Optional Utility Chase forSide or Central cabinets
QUAD ELECTRICAL BOXSupplied By A-DEC(Check amperagerequirements)
Locate as needed
3/4"X-Ray(lowvoltage)
OptionalUtility Chase
03/16
9"171 8"
9"
03/16
03/1
6
09/05
09/05
09/05
09/05
4/02
4/02
Air
Electrical
Optional
Pow
er D
istri
butio
n Bo
xLo
cate
as
need
ed
QUAD ELECTRICAL BOX
Supplied by A-dec
(check amperage
requirements)
Locate as needed
Drain
Cold
Water
Hot
Water
Opt
iona
l Util
ityC
hase
Opt
iona
l Util
ityC
hase
03/1
603
/16
01/19
Power Distribution BoxLocate as needed
QUAD ELECTRICAL BOXSupplied by A-dec(check amperage
requirements)Locate as needed
Vacuum
ON2
O2
Air
Pow
er S
uppl
y(lo
cate
as
need
ed)
Opt
iona
l Util
ity C
hase
from
12 O
'Clo
ck to
Cha
ir U
tility
Box
Pow
er D
istri
butio
n Bo
x(lo
cate
as
need
ed)
Electrical
Opt
iona
l Util
ity C
hase
for
Side
or C
entra
l cab
inet
sO
ptio
nal U
tility
Cha
se fo
rSi
de o
r Cen
tral c
abin
ets
QUAD ELECTRICAL BOX
Supplied By A-DEC
(Check amperage
requirements)
Locate as needed
3/4"
X-Ray
(low
voltage)
Opt
iona
lU
tility
Cha
se
03/1
6
09/05
Power Distribution BoxLocate as needed
QUAD ELECTRICAL BOXSupplied by A-dec(check amperagerequirements)
Locate as needed
LC
01/1
9
VAC
UU
M
DR
AIN
5/8"
O.D
. (16
mm
) Tub
ing
For C
entra
l Va
cuum
Onl
y(s
ee G
ener
al U
tility
Not
es)
Opt
iona
l2"
DAT
AC
ON
DU
IT(lo
cate
as
need
ed)
1-1/
2" (3
8 m
m) N
omin
alPi
pe F
or G
ravi
ty D
rain
(whe
n re
quire
d)
WAT
ER
AIR
Hospital-Grade Quad ElectricalBox Supplied by Contractor(check amperage requirements)
ELEC
TRIC
AL
Air
Electrical
Optional
Power Distribution Box
Locate as needed
QUAD ELECTRICAL BOX
Supplied by A-dec
(check amperage
requirements)
Locate as needed
Drain
Cold
Water
HotWater
Optional Utility
Chase
Optional Utility
Chase
03/16
Vacuum O N2 O2
Air
Power Supply(locate as needed)
Optional Utility Chase from12 O'Clock to Chair Utility Box
Power Distribution Box(locate as needed)
Electrical
Optional Utility Chase forSide or Central cabinets
Optional Utility Chase forSide or Central cabinets
QUAD ELECTRICAL BOXSupplied By A-DEC(Check amperagerequirements)
Locate as needed
3/4"X-Ray(lowvoltage)
OptionalUtility Chase
03/16
03/16
09/05
09/05
Air
Electric
al
Optional
Power D
istribution BoxLocate as needed
QUAD ELECTRICAL BOX
Supplied by A-dec
(check amperage
requirements)
Locate as needed
Drain
Cold
Water
Hot
Water
Optional U
tilityC
hase
Optional U
tilityC
hase
03/1603/16
PEDO
DTR
GENERAL
ORAL SURGERY
11638"
567 8"
497 8"
497 8"
567 8"
567 8"
497 8"
497 8"
567 8"
55
LC
01/19
VACU
UM
DR
AIN
5/8" O.D
. (16 mm
) TubingFor C
entral Vacuum O
nly(see G
eneral Utility N
otes)
Optional
2" DATA
CO
ND
UIT
(locate as needed)
1-1/2" (38 mm
) Nom
inalPipe For G
ravity Drain
(when required)
WATER
AIR
Hospital-Grade Quad ElectricalBox Supplied by Contractor(check amperage requirements)
ELECTR
ICAL
VacuumON2O2
Air
Power Supply(locate as needed)
Optional Utility Chase from12 O'Clock to Chair Utility Box
Power Distribution Box(locate as needed)
Electrical
Optional Utility Chase forSide or Central cabinets
Optional Utility Chase forSide or Central cabinets
QUAD ELECTRICAL BOXSupplied By A-DEC(Check amperagerequirements)
Locate as needed
3/4"X-Ray(lowvoltage)
OptionalUtility Chase
03/16
09/05
09/05
Air
Electrical
Optional
Pow
er D
istri
butio
n Bo
xLo
cate
as
need
ed
QUAD ELECTRICAL BOX
Supplied by A-dec
(check amperage
requirements)
Locate as needed
Drain
Cold
Water
Hot
Water
Opt
iona
l Util
ityC
hase
Opt
iona
l Util
ityC
hase
03/1
603
/16
Air
Electrical
Optional
Power Distribution Box
Locate as needed
QUAD ELECTRICAL BOX
Supplied by A-dec
(check amperage
requirements)
Locate as needed
Drain
Cold
Water
Hot
Water
Optional Utility
Chase
Optional Utility
Chase
03/16
ENDO
PERIO
217 8"
27"
605 8"
5738" 753
8"
40"
DTR DTR
LC
01/1
9
VAC
UU
M
DR
AIN
5/8"
O.D
. (16
mm
) Tub
ing
For C
entra
l Va
cuum
Onl
y(s
ee G
ener
al U
tility
Not
es)
Opt
iona
l2"
DAT
AC
ON
DU
IT(lo
cate
as
need
ed)
1-1/
2" (3
8 m
m) N
omin
alPi
pe F
or G
ravi
ty D
rain
(whe
n re
quire
d)
WAT
ER
AIR
Hospital-Grade Quad ElectricalBox Supplied by Contractor(check amperage requirements)
ELEC
TRIC
AL
LC
01/1
9
VAC
UU
M
DR
AIN
5/8"
O.D
. (16
mm
) Tub
ing
For C
entra
l Va
cuum
Onl
y(s
ee G
ener
al U
tility
Not
es)
Opt
iona
l2"
DAT
AC
ON
DU
IT(lo
cate
as
need
ed)
1-1/
2" (3
8 m
m) N
omin
alPi
pe F
or G
ravi
ty D
rain
(whe
n re
quire
d)
WAT
ER
AIR
Hospital-Grade Quad ElectricalBox Supplied by Contractor(check amperage requirements)
ELEC
TRIC
AL
Air
Electrical
Optional
Power Distribution Box
Locate as needed
QUAD ELECTRICAL BOX
Supplied by A-dec
(check amperage
requirements)
Locate as needed
Drain
Cold
Water
HotWater
Optional Utility
Chase
Optional Utility
Chase
03/16
Air
Hot
Water
Cold
Water
Optional
Loop
Vent
Drain
Electrical
Opt
iona
l Pow
er S
uppl
yLo
cate
in G
ener
al A
rea
X-Ray
Electrical
Pow
er D
istri
butio
n Bo
xLo
cate
as
need
ed
QUAD ELECTRICAL BOX
Supplied By A-DEC
(Check amperage
requirements)
Locate as needed
3/4"
X-Ray
(low
voltage)
Pow
er D
istri
butio
n Bo
xLo
cate
as
need
ed
Opt
iona
l Util
ity C
hase
from
Cab
inet
to C
hair
Util
ity B
ox
Opt
iona
l Util
ity C
hase
from
Cab
inet
to C
hair
Util
ity B
ox
03/1
6
Air
Electric
al
Optional
Power D
istribution BoxLocate as needed
QUAD ELECTRICAL BOX
Supplied by A-dec
(check amperage
requirements)
Locate as needed
Drain
Cold
Water
Hot
Water
Optional U
tilityC
hase
Optional U
tilityC
hase
03/16
Vacuum O N2 O2
Air
Power Supply(locate as needed)
Optional Utility Chase from12 O'Clock to Chair Utility Box
Power Distribution Box(locate as needed)
Electrical
Optional Utility Chase forSide or Central cabinets
Optional Utility Chase forSide or Central cabinets
QUAD ELECTRICAL BOXSupplied By A-DEC(Check amperagerequirements)
Locate as needed
3/4"X-Ray(lowvoltage)
OptionalUtility Chase
03/16
Vacuum O N2 O2
Air
Power Supply(locate as needed)
Optional Utility Chase from12 O'Clock to Chair Utility Box
Power Distribution Box(locate as needed)
Electrical
Optional Utility Chase forSide or Central cabinets
Optional Utility Chase forSide or Central cabinets
QUAD ELECTRICAL BOXSupplied By A-DEC(Check amperagerequirements)
Locate as needed
3/4"X-Ray(lowvoltage)
OptionalUtility Chase
03/16
14"
221 8" 14
"
151 4"
03/16
03/16
09/05
09/05
09/05
09/05
LC
01/1
9
VAC
UU
M
DR
AIN
5/8"
O.D
. (16
mm
) Tub
ing
For C
entra
l Va
cuum
Onl
y(s
ee G
ener
al U
tility
Not
es)
Opt
iona
l2"
DAT
AC
ON
DU
IT(lo
cate
as
need
ed)
1-1/
2" (3
8 m
m) N
omin
alPi
pe F
or G
ravi
ty D
rain
(whe
n re
quire
d)
WAT
ER
AIR
Hospital-Grade Quad ElectricalBox Supplied by Contractor(check amperage requirements)
ELEC
TRIC
AL
LC
01/1
9
VAC
UU
M
DR
AIN
5/8"
O.D
. (16
mm
) Tub
ing
For C
entra
l Va
cuum
Onl
y(s
ee G
ener
al U
tility
Not
es)
Opt
iona
l2"
DAT
AC
ON
DU
IT(lo
cate
as
need
ed)
1-1/
2" (3
8 m
m) N
omin
alPi
pe F
or G
ravi
ty D
rain
(whe
n re
quire
d)
WAT
ER
AIR
Hospital-Grade Quad ElectricalBox Supplied by Contractor(check amperage requirements)
ELEC
TRIC
AL
Air
Electrical
Optional
Power Distribution Box
Locate as needed
QUAD ELECTRICAL BOX
Supplied by A-dec
(check amperage
requirements)
Locate as needed
Drain
Cold
Water
HotWater
Optional Utility
Chase
Optional Utility
Chase
03/16
Air
Hot
Water
Cold
Water
Optional
Loop
Vent
Drain
Electrical
Opt
iona
l Pow
er S
uppl
yLo
cate
in G
ener
al A
rea
X-Ray
Electrical
Pow
er D
istri
butio
n Bo
xLo
cate
as
need
ed
QUAD ELECTRICAL BOX
Supplied By A-DEC
(Check amperage
requirements)
Locate as needed
3/4"
X-Ray
(low
voltage)
Pow
er D
istri
butio
n Bo
xLo
cate
as
need
ed
Opt
iona
l Util
ity C
hase
from
Cab
inet
to C
hair
Util
ity B
ox
Opt
iona
l Util
ity C
hase
from
Cab
inet
to C
hair
Util
ity B
ox
03/1
6
Air
Electric
al
Optional
Power D
istribution BoxLocate as needed
QUAD ELECTRICAL BOX
Supplied by A-dec
(check amperage
requirements)
Locate as needed
Drain
Cold
Water
Hot
Water
Optional U
tilityC
hase
Optional U
tilityC
hase
03/16
Vacuum O N2 O2
Air
Power Supply(locate as needed)
Optional Utility Chase from12 O'Clock to Chair Utility Box
Power Distribution Box(locate as needed)
Electrical
Optional Utility Chase forSide or Central cabinets
Optional Utility Chase forSide or Central cabinets
QUAD ELECTRICAL BOXSupplied By A-DEC(Check amperagerequirements)
Locate as needed
3/4"X-Ray(lowvoltage)
OptionalUtility Chase
03/16
Vacuum O N2 O2
Air
Power Supply(locate as needed)
Optional Utility Chase from12 O'Clock to Chair Utility Box
Power Distribution Box(locate as needed)
Electrical
Optional Utility Chase forSide or Central cabinets
Optional Utility Chase forSide or Central cabinets
QUAD ELECTRICAL BOXSupplied By A-DEC(Check amperagerequirements)
Locate as needed
3/4"X-Ray(lowvoltage)
OptionalUtility Chase
03/1614
"
221 8" 14
"
14"
03/16
03/16
09/05
09/05
09/05
09/05
4/02
4/02
4/02
4/02
DTR
5678" 497
8" 4978" 567
8" 5678" 497
8" 4978" 567
8" 5518"
DTR DTR
DTR
ICC
LC
01/19
VACU
UM
DR
AIN
5/8" O.D
. (16 mm
) TubingFor C
entral Vacuum O
nly(see G
eneral Utility N
otes)
Optional
2" DATA
CO
ND
UIT
(locate as needed)
1-1/2" (38 mm
) Nom
inalPipe For G
ravity Drain
(when required)
WATER
AIR
Hospital-Grade Quad ElectricalBox Supplied by Contractor(check amperage requirements)
ELECTR
ICAL
Air
Electrical
Optional
Power Distribution Box
Locate as needed
QUAD ELECTRICAL BOX
Supplied by A-dec
(check amperage
requirements)
Locate as needed
Drain
Cold
Water
Hot
Water
Optional Utility
Chase
Optional Utility
Chase
03/16
VacuumON2O2
Air
Power Supply(locate as needed)
Optional Utility Chase from12 O'Clock to Chair Utility Box
Power Distribution Box(locate as needed)
Electrical
Optional Utility Chase forSide or Central cabinets
Optional Utility Chase forSide or Central cabinets
QUAD ELECTRICAL BOXSupplied By A-DEC(Check amperagerequirements)
Locate as needed
3/4"X-Ray(lowvoltage)
OptionalUtility Chase
03/16
03/16
09/05
09/05
Air
Electrical
Optional
Pow
er D
istri
butio
n Bo
xLo
cate
as
need
ed
QUAD ELECTRICAL BOX
Supplied by A-dec
(check amperage
requirements)
Locate as needed
Drain
Cold
Water
Hot
Water
Opt
iona
l Util
ityC
hase
Opt
iona
l Util
ityC
hase
03/1
603
/16
217 8"
27"
605 8"
5738"753
8"
40"
ORAL SURGERY
60"
03/16
03/1
6
7734"
11614" 1323
4"
6938"
11638"1323
4"
XRAY
19A-dec Sterilization and Material Management Solutions A-dec Sterilization and Material Management Solutions
Transitional endcaps allow you to connect multiple configurations.
A transitional endcap paired with a divider provides a physical barrier between the Receiving and Cleaning, and Preparation and Packaging areas.
U-SHAPEDSterilization Center
L-SHAPEDSterilization Center
GALLEYSterilization Center
STRAIGHTSterilization CenterCOMPACT FOR SMALL PRACTICES
Flexible modules allow small-space practices to fit a compact, efficient sterilization center into the plan. This one offers room to reprocess, plus eight feet of additional storage.
HIGH CAPACITY FOR HIGH VOLUME
Large clinics, DSOs and schools, need to process a high volume of instruments, in a space that can handle multiple team members. This example is 22 feet.
SCALABLE CAPACITYLets you maximize practice space—no matter the size.
20 A-dec Sterilization and Material Management Solutions
85.0882.00/PP/2.5M/3-20/Rev A
©2020 A-dec Inc. All rights reserved. The colors and products shown may vary from the actual materials and are subject to change without notice. Please see your authorized A-dec dealer for accurate color samples and the most current product information. All trademarks in this document are subject to the trademark rights of A-dec, its affiliates, and their collective suppliers in the United States and foreign countries.For a full list of trademarks visit: a-dec.com/legal/trademarks.
A-dec Headquarters2601 Crestview Drive
Newberg, Oregon 97132 USAT: 1.800.547.1883 within USA/CAN
T: +1.503.538.7478 outside USA/CANF: +1.503.538.0276
a-dec.com
A-dec AustraliaT: 1.800.225.010 within AUS
T: +61.(0)2.8332.4000 outside AUS
A-dec ChinaT: 400.600.5434 within CN
T: +86.571.89026088 outside CN
A-dec United KingdomT: 0800.233285 within UK
T: +44.(0).24.7635.0901 outside UK