DEM RANGECommercial Kitchen Exhaust System
Technical introduction
Experience and high technology at your service
GENERAL DESCRIPTION
Maico Ventilation Pvt. Ltd is ISO 9001: 2015 company certi�ed.
DYNAIR® is the industrial division of Maico Italia S.p.A. and is a well known brand name at global level in the industrial ventilation and plant engineer-ing sector. Technological expertise, high production capacities, strong research and investment policies together with a personalized back-up service focused on customer needs have, for over 30 years, been the qualities that distinguish our company: Italian excellence renowned throughout the world and an industrial concern forti�ed by belonging to Maico Holding GmbH, the German group that leads the way in the ventila-tion industry.
Living in a market in continuous evolution, DYNAIR® bases its force on a step by step project follow-up in close collaboration with the customer to create tailored and highly reliable solutions.
With the new and wide range of kitchen exhaust units(DEM), Dynair has diversi�ed its current range of products to meet customers requirement in HVAC �eld. DYNAIR’s products follow stringent policy of research and development. With safety as a priority during production, all products use top quality components that meet (*ETL relevant as per UL 710 standards.)*Applicable only for DYNAIR model DEV.
Our Total Quality policy is ensured by standard working procedures, with tests and inspections during all production phases.
An e�cient & economical solution to exhaust contaminated air from kitchen hood.They are suitable for conveying kitchen exhaust air, upto a maximum temperature of 80°C.The removal of grease from the exhaust air �ow is a very important part of commercial kitchen operation. If there is no proper grease trap at kitchen hood it could:
1. Increase �re hazard at exhaust duct.2. Increase the frequency of expensive duct cleaning.3. Create bad odor in or near the restaurant surroundings.4. Increase the collection of grease on the roof top which could cause deterioration of roof material (Filter Bank), These problems can be greatly reduced through the use of proper grease trap device at kitchen hood itself.
With our production capability, wide range of �nished products and compo-nents warehouse, we ensure quick delivery to all our customers. Our sta� is trained and dedicated to provide before and after technical plus sales services.
DEM RangeCommercial Kitchen Exhaust System Pre & Bag
Filter Module
Hepa/BioFilter Module
(Optional)
Activated Carbon Filter
ModuleFan Module
(DIDW as standard)
From KitchenHood
Bag Filter Access
Door
Hepa Filter Access
Door
ESPAccessDoor
Carbon FilterAccess Door Fan Access
Door
3
Nomenclature
To Atmosphere
Pre Filter Access
Door
4
Nomenclature
PANE
L TH
K
1. P
anel
Thi
ckne
ss 2
5 m
m.
2. P
anel
Thi
ckne
ss 5
0 m
m.
RODU
CT L
INE
DEM
- Dy
nair
ecol
ogy
Ven�
lato
r
MO
DEL
AIRF
LOW
RAT
E
DEM
RAN
GE01
= DE
M 0
102
= DE
M 0
203
= DE
M 0
304
= DE
M 0
405
= DE
M 0
5CF
M X
100
0
STAG
E-3
FILT
ER T
YPE
X =
No F
ilter
b =
Bag
Filte
r
FAN
MO
DEL
280
to 1
000
POW
ER S
UPPL
YE=
380
V/3P
H/60
HzF=
220
- 240
V/1P
H/50
HzG=
380
- 420
V/3P
H/50
HzK=
460V
/3PH
/60H
zS=
220
- 230
V/1P
H/60
Hz06
= DE
M 0
607
= DE
M 0
708
= DE
M 0
809
= DE
M 0
910
= DE
M 1
011
= DE
M 1
112
= DE
M 1
2
14=
DEM
14
13=
DEM
13
15=
DEM
15
16=
DEM
16
17=
DEM
17
18=
DEM
18
STAG
E -2
FILT
ER T
YPE
X =
No F
ilter
P =
Pre
Filte
r
STAG
E -4
FILT
ER T
YPE
X =
No A
lter
Bi =
Bio
Filt
erH
= He
pa F
ilter
STAG
E -5
FILT
ER T
YPE
X =
No F
ilter
C= C
arbo
n Fi
lter
ACCE
SSO
RIES
00 =
No
Addi
�ona
l Fea
ture
s01
= C
ontr
ol P
anel
02 =
Fire
Dam
per
03 =
UV
Light
04
= O
dour
Neu
tral
iser
STAG
E -1
ESP
X =
No E
SPE
= ES
P
MO
TOR,
W3k
w =
030
00
042
005
ESP
PB
BiC
1000
00G
0300
DEM
5
Filtration System AndConstruction
Dirty Air Clean Air
FILTRATION SYSTEM:
A. First stage of �ltration Three stage �ltration systems, which includes:
Stage 3 : Synthetic Bag Filter:1. EN 779 : F92. Arrestance (ASHRAE 52.1) : 99%3. MERV Rating (ASHRAE 52.2) : MERV154. Eurovent : EU9
Stage 2 : Poly�bre Pleated Filter:1. EN 779 : G42. Arrestance (ASHRAE 52.1) : 90-94%3. MERV Rating (ASHRAE 52.2) : MERV84. Eurovent : EU4
Stage 1 : Electrostatic PrecipitatorAir is drawn by the motor/blower through a �lter bank which traps large dust particles. The remaining particles, some as small as 0.01 microns, pass into a strong electrical �eld (ionizing section) where the particulate receives an electrical charge. The charged particles then pass into a collector plate section made up of a series of equally spaced parallel plates. Each alternate plate is charged with the same polarity as the particles, which repel, while the interleaving plates are grounded, which attract and collect.
Stage 4 : Bio-Hepa Filter (Optional) 1. EN 779 : H142. Arrestance (ASHRAE 52.1) : 99.995%3. MERV Rating (ASHRAE 52.2) : NA4. Eurovent : EU14
B. Second stage of �ltration S4: Carbon Filter:Durable non-woven polyester base media, impregnated with activated carbon.The unique combination of high quality activated carbon and polyester a�ords odour and particulate trapping e�ciency while maintaining excellent air�ow properties.
FAN SECTION:• DEM series are with DIDW,fan which allows obtaining two
orientations (0° & b 90°) with the same fan.• The key features associated with DEM:
• AMCA certified fan for air and sound • PPGI casing, suitable for outdoor installation • Backward curved impellers are made of cold-rolled sheet steel • Statically & dynamically balanced • Fan & motor assembly mounted on a common base frame and isolated from the main structure by anti vibration mounts and �exible joint on inlet and outlet (optional) • DIDW backward curved type fan (SISW Optional) • Standard accessories with inspection door & drain plug for periodic maintenance • Powder coated impeller, (non-sticky)
CONSTRUCTION:• Filter section: Pentapost design & have strong three way angle
joints of reinforced nylon corners to form a rigid frame structure. Rigid frame work comprises an assembly of externally chamfered extruded aluminium pro�le & nylon corner joints. Inner & outer skin: Standard pre-coated GI sheet, the double skin is to retain the insulation surface clean & to have a smooth surface.
• Asynchronous three-phase motors according to international standards IEC 60034,IEC 60072,EMC2004/108/CE, LVD2006/95/CE, CE marked, IP55, class F, suitable to S1 service (continuous working at constant load).
OPTIONAL FEATURES:• Spray system works by producing a fine atomized mist that is
delivered through strategically placed nozzles in the stack, which actively reduces odour , neutralizing it before it leaves the stack.
• UV filtration - UVC in DEM are another option in odour & grease control, the most e�ective method common today for eliminating unpleasant odours, grease & oil mist from kitchen hood.
• Electrostatic precipitator with wash module
Features & bene�ts Of UV �ltration -
1. Quick and easy snap in installation.2. No noise.3. No pressure drop.4. Easy maintenance.5. High output green lamps contain < 8 mg. of mercury.6. Water tight connections for lamp and wiring.7. Produce no Ozone or other contaminants.
ACCESSORIES:• Control panel (motor starter, status panel for filter bank)• Fire damper• Inlet/outlet flexible connectors• Anti vibration supports• Outlet flange• Inverter speed controllers• Weatherproof canopy• Belt protection
6
Selection Software
Ecology Unit Selection Software:
DYNAIR's Ecology Unit selection software provides the complete details of design and submittal generated for the Ecology Units. The system is integrated so as to eliminate wherever possible the re-entry of information and thereby minimize data entry errors. The program is user-friendly and maintained wherever practical for the customers.The software intelligently selects the optimum requirement of Ecology Units from our standard database and selects the optimum selection as per the customers' speci�cations.The software will carry out the calculations and generate su�cient information to have options available within the program.
7
Technical Output Of DEM(Technical Specification)
Date: 8/14/2016
Technical Specification Project name :Salwa Beach Resort Doha WinTADS Lite - 1.10.00042.0 Quotation no : 0194-15-00 / 001
Page 1 of 3
CUSTOMER DETAILS Customer Name Customer Number Address Town Postcode Country GENERAL DATA Product Ecology Unit Customer reference ECU PS-401 Number off 1 Unit configuration Inline Location Internal Total weight (each) kg 582.09 Roof type None Outdoor design temperature
°C 0.0
Frequency 125Hz 250Hz 500Hz 1kHz 2kHz 4kHz 8kHz dB(A) Radiated casework SWL, dB
52 48 74 66 63 55 33 73
PANEL DATA Panel internal finish Standard Panel external finish Standard CASING DATA Base frame material Galvanised 1.5mm C-
channel Base frame height mm 80
SUPPLY DATA Type DEM-02 Air volume m³/s 1.00 External static Pa 623 Unit velocity m/s 1.02 Internal skin material GI 0.5mm External skin material Pre Painted GI 0.5mm Panel type 25 mm SFPe kW/m³/s 2.00 SFPv kW/m³/s 1.82 Operating sound power level
Frequency 125Hz 250Hz 500Hz 1kHz 2kHz 4kHz 8kHz dB(A) Inlet dB 90 83 87 84 80 78 70 89 Outlet dB 90 83 87 84 80 78 70 89
8
Standard Control PanelSchematic (Control)
9
Standard Control PanelSchematic (Power)
10
General Assembly Layout
UN
IT L
ENG
TH
UN
IT L
ENG
TH
AS
PER
MO
DEL
A
AS
PER
MO
DEL
C
UNIT WIDTHUNIT HEIGHT
A
Proj
ect n
ame:
STD
. DR
G. M
AIC
OQ
uota
tion
No:
Dat
e:29
/03/
15
Scal
e: n
ot d
raw
to s
cale
Com
men
ts:
A,B
& C
dim
ensi
ons
as p
er E
SPUn
it No
:Un
it D
esc:
DEM
STD
. DRG
WIT
H ES
P
FO
R AL
L M
OD
ELQ
ty U
nits
:1 N
o./U
NIT
Wei
ght:
Proj
ect N
ame:
STD
. DRG
. MAI
COEx
h ai
r:Su
p ai
r :
DAT
E:-2
9/03
/16
Engi
neer
:- K
S.
UN
IT W
IDTH
PRE-
FILT
ER
BAG
-FIL
TER H
EPA
-FIL
TER
CARB
ON
-FIL
TER
FAN
ESP
ESP
PRE-
FILT
ER BAG
-FIL
TER
HEP
A-F
ILTE
R(O
PTIO
NA
L)
(OPT
ION
AL)
CARB
ON
-FIL
TER
FAN
DU
CT
940
700
700
AS
PER
MO
DEL
940
700
700
AS
PER
MO
DEL
DU
CT
11
Ecology Unit Dimensional Details
Hei
ght
Wid
th
ESP
DU
CTPr
e-�l
ter
Pre+
Bag
Filte
r H
epa
�lte
r Ca
rbon
�lte
rBl
ower
& M
otor
(DID
W)
Blow
er &
Mot
or (D
IDW
with
UV
light
)
CFM
CMH
AB
MO
DEL
L x
W x
HL2
L3L4
L5L6
L7L8
DEM
-115
0025
4980
085
0Y2
500
x 1
635x
680x
534
500
360
940
700
700
950
1250
DEM
-220
0033
9890
012
00Y5
000
x 1
635x
1230
x534
500
360
940
700
700
950
1250
DEM
-325
0042
4895
012
00Y5
000
x 1
635x
1230
x534
500
360
940
700
700
1100
1400
DEM
-430
0050
9795
016
50Y5
000
x 1
635x
1230
x534
500
360
940
700
700
110 0
1400
DEM
-535
0059
4795
016
75Y7
500A
x 1
635x
1664
x534
500
360
940
700
700
1100
1400
DEM
-640
0067
9610
0017
00Y7
500A
x 1
635x
1664
x534
500
360
940
700
700
1265
1565
DEM
-750
0084
9510
5021
50Y5
000
x 2
635x
1230
x106
880
036
094
070
070
012
6515
65
DEM
-860
0010
194
1650
1700
Y500
0 x
263
5x12
30x1
068
800
360
940
700
700
1400
1700
DEM
-975
0012
743
1650
1725
Y750
0A x
263
5x16
64x1
068
800
360
940
700
700
1650
1950
DEM
-10
1000
016
990
1800
2150
Y750
0A x
363
5x16
64x1
602
800
360
940
700
700
1760
2060
DEM
-11
1200
020
388
1800
2600
Y750
0A x
363
5x16
64x1
602
800
360
940
700
700
1760
2060
DEM
-12
1500
025
485
1800
2625
Y750
0A x
463
5x33
28x1
068
800
360
940
700
700
2000
2300
DEM
-13
1800
030
582
1800
2650
Y750
0A x
463
5x33
28x1
068
800
360
940
700
700
2100
2400
DEM
-14
2000
033
980
2300
2600
Y750
0A x
663
5x33
28x1
602
800
360
940
700
700
2100
2400
DEM
-15
2400
040
776
2300
2600
Y750
0A x
663
5x33
28x1
602
800
360
940
700
700
2250
2550
DEM
-16
3000
050
970
2450
2600
Y750
0A x
863
5x33
28x2
136
800
360
940
700
700
240 0
2700
DEM
-17
3500
059
465
3350
2600
Y750
0A x
863
5x33
28x2
136
800
360
940
700
700
2400
2700
DEM
-18
4000
067
960
3350
2600
Y750
0A x
10
635x
3328
x267
080
036
094
070
070
027
0030
00
DEM
Mod
el
Air�
ow R
ate
ESP
Not
e :- 1)
All
Dim
ensi
ons
are
in m
m.
2) L
engt
hs S
how
n ar
e of
Indi
vidu
al M
odul
e.3)
Ple
ase
cons
ider
thes
e di
men
sion
s fo
r 25m
m p
anel
.4)
Add
100
mm
in th
e Ec
olog
y un
it he
ight
for b
ase
chan
nel.
5) D
ynai
r res
erve
the
right
, whi
le le
avin
g th
e es
sent
ial c
hara
cter
istic
s th
e sa
me,
to m
odify
the
data
, pho
togr
aph
and
enyt
hing
els
e sh
ows
in th
e ab
ove
with
out p
rior w
arni
ng.
Code
: DEM
/01/
17
Maico Ventilation Pvt. LTDPlot I-02, Part-1, Khed City, Rajgurunagar, Pune – 410505, Maharashtra, India
INDIA
Maico Factories