12
www.flowcreteaustralia.com.au DECKSHIELD Car Park Decking Systems for: 9 Exposed Decks 9 Internal Decks 9 Ramps 9 Walkways/Stairwells 9 Demarcation 9 Service Corridors

DECKSHIELD - Flowcrete Australia · Deckshield Range Technical Profile Application Suitability Product Selector Multi-storey car parks have always been many customers’ first point

Embed Size (px)

Citation preview

Page 1: DECKSHIELD - Flowcrete Australia · Deckshield Range Technical Profile Application Suitability Product Selector Multi-storey car parks have always been many customers’ first point

www.flowcreteaustralia.com.au

DECKSHIELD Car Park Decking Systems for:

9 Exposed Decks 9 Internal Decks 9 Ramps

9 Walkways/Stairwells 9 Demarcation 9 Service Corridors

Page 2: DECKSHIELD - Flowcrete Australia · Deckshield Range Technical Profile Application Suitability Product Selector Multi-storey car parks have always been many customers’ first point

Deckshield Range Technical Profile

Application Suitability

Product Selector

Multi-storey car parks have always been many customers’ first point of contact with commercial destinations, but it is only recently that developers have made efforts to improve the quality of the car park experience.

Although often underestimated, the correct specification of waterproofing and surfacing materials is critical, within the car park environment, to delivering a long-term, structurally protected and safe facility for car park operators and vehicle owners.

Flowcrete Australia’s Deckshield range offers a number of colourful deck coating solutions geared up to provide slip-resistance, durability and an excellent service life as well as stand-up to common car park problems. What’s more, Flowcrete’s deck coating systems are Singapore Green Label certified.

Each parking facility consists of a range of zones or areas and requires a number of surface applications as a result. Flowcrete offers a wide range of flooring products to meet the surface requirements of the entire car park as well as neighbouring zones.

Exposed Decks Internal Decks Ramps

Instructional Signage Demarcation Kerbs/Islands

Line Marking

Multi-storey Top Deck

RampsMulti-storey

Internal Deck

StairwaysTurning Circles

Stair Landings

Entrance to Shopping Malls

Page 3: DECKSHIELD - Flowcrete Australia · Deckshield Range Technical Profile Application Suitability Product Selector Multi-storey car parks have always been many customers’ first point

Deckshield ID(1.5mm)

Deckshield UV (WB)

Deckshield Finish

Deckshield Oxide/Quartz

Deckshield Finish

Prepared Substrate

** C

ure

times

at t

empe

ratu

res

betw

een

0–30

˚C c

an b

e ac

hiev

ed b

y al

terin

g th

e qu

antit

y of

cat

alys

t use

d.

For

appl

icat

ions

falli

ng o

utsi

de o

f thi

s te

mpe

ratu

re r

ange

, ple

ase

cont

act y

our

loca

l Flo

wcr

ete

Tech

nica

l Dep

artm

ent.

A low VOC, flexible polyurethane deck coating, system that transforms intermediate decks of multi-storey parking structures.

Typically used to cosmetically enhance, reduce noise, protect and brighten internal car parks.

Technical Profile

FIRE RESISTANCE

EN13501–1 B – s1

SLIP RESISTANCE

Method described inAS4586–2013

Dry & Wet Rating isdependant on specification(in accordance with AS4586–2013)

The slipperiness of flooring materials can change significantly, due to the installation process, after short periods of use, due to inappropriatemaintenance, longer-term wear and/or surface contaminants (wet or dry).

Textured systems are recommended to meet slip resistance value requirements for wet conditions and/or surface contaminants (wet or dry) — please contact our Technical Advisors for further details.

TEMPERATURE RESISTANCE

Softens of 70°C Hardens on cooling

WATER PERMEABILITY

Karsten Test Nil (Impermeable)

RESISTANCE TO CHLORIDE IONS

DOT BD47/94: Appendix BMethod B4, 2 (d)

No chloride ion penetration after 28 days

BOND STRENGTH

ASTM D4541 (Pull-Off Test) >1.5MPa*

ABRASION RESISTANCE

Taber Abrader ASTM D4060

0.1mg loss per 1000 cycles 1kg Load using CS17 wheels

CHEMICAL RESISTANCE

Contact Technical Department

VOC CONTENT

ISO11890-2 Very low < 20 g/L

ENVIRONMENTALLY FRIENDLY

Green Label certified — 032–089 EnvironmentallyPreferred Coating

UV LIGHT RESISTANCE

Excellent (Non Yellowing)

SPEED OF CURE** 10˚C 20˚C 30˚C

Light Traffic 30 hrs 18 hrs 12 hrs

Full Traffic 36 hrs 48 hrs 24 hrs

Full Chemical Cure 12 days 7 days 6 days

Attractive: Brightens up dull, dark and musty car parks and suspended floors.

Reduces Noise: Minimises unwanted noise from tyre squeal.

Resistant: Resistance to chemicals, fire and has a low slip potential.

*Assumes concrete compressive strength is greater than 25 N/mm2

032-089 Environmentally Preferred

Coating

Environmentally Friendly: Low in Votaile Organic Compounds (VOCs) and solvent free

Chemical Resistance

Petrol 9

Diesel 9

Antifreeze 9

Hydraulic Fluid 9

Chlorides 9

Battery Acids 9

These figures are typically properties achieved in laboratory tests at 20°C and at 50% Relative Humidity.

Page 4: DECKSHIELD - Flowcrete Australia · Deckshield Range Technical Profile Application Suitability Product Selector Multi-storey car parks have always been many customers’ first point

** C

ure

times

at t

empe

ratu

res

betw

een

0–30

˚C c

an b

e ac

hiev

ed b

y al

terin

g th

e qu

antit

y of

cat

alys

t use

d.

For

appl

icat

ions

falli

ng o

utsi

de o

f thi

s te

mpe

ratu

re r

ange

, ple

ase

cont

act y

our

loca

l Flo

wcr

ete

Tech

nica

l Dep

artm

ent.

A car park deck coating system providing a colourful, watertight surface for intermediate decks of multi-storey structures.

Typically used to cosmetically enhance, reduce noise and brighten internal car parks.

Deckcoat EP Topcoat

Natural Quartz Scatter

DeckcoatEP Primer

Prepared Substrate

Technical Profile

FIRE RESISTANCE

EN 13505–1 B – s1

SLIP RESISTANCE

Method described inAS4586–2013

Dry & Wet Rating isdependant on specification(in accordance with AS4586–2013)

The slipperiness of flooring materials can change significantly, due to the installation process, after short periods of use, due to inappropriatemaintenance, longer-term wear and/or surface contaminants (wet or dry).

Textured systems are recommended to meet slip resistance value requirements for wet conditions and/or surface contaminants (wet or dry) — please contact our Technical Advisors for further details.

TEMPERATURE RESISTANCE

Tolerant up to 60°C

WATER PERMEABILTY

Karsten Test Nil (Impermeable)

SURFACE HARDNESS

Koenig Hardness Test 180 secs

BOND STRENGTH

ASTM D4541 (Pull-Off Test) >1.5MPa*

ABRASION RESISTANCE

Taber Abrader BS8204–2 80mg loss per 1000 cycles 1kg Load using CS10 wheelsGrade AR2

CHEMICAL RESISTANCE

Contact Technical Department

ENVIRONMENTALLY FRIENDLY

TGreen Label certified — 032–089 EnvironmentallyPreferred Coating option available.

SPEED OF CURE** 10˚C 20˚C 30˚C

Light Traffic 48 hrs 24 hrs 18 hrs

Full Traffic 72 hrs 48 hrs 36 hrs

Full Chemical Cure 12 days 7 days 6 days

032-089 Environmentally Preferred

Coating

Attractive: Brightens up dull, dark and musty car park environments.

Resistant: Resistance to chemicals, fire and has a low slip potential.

Environmentally Friendly: Low in Volatile Organic Compounds(VOCs) and solvent free.

Chemical Resistance

Petrol 9

Diesel 9

Antifreeze 9

Hydraulic Fluid 9

Chlorides 9

Durable: Hard wearing, durable and abrasion resistant.

Deckcoat EP(0.4–1mm)

*Assumes concrete compressive strength is greater than 25 N/mm2

These figures are typically properties achieved in laboratory tests at 20°C and at 50% Relative Humidity.

Page 5: DECKSHIELD - Flowcrete Australia · Deckshield Range Technical Profile Application Suitability Product Selector Multi-storey car parks have always been many customers’ first point
Page 6: DECKSHIELD - Flowcrete Australia · Deckshield Range Technical Profile Application Suitability Product Selector Multi-storey car parks have always been many customers’ first point

** C

ure

times

at t

empe

ratu

res

betw

een

0–30

˚C c

an b

e ac

hiev

ed b

y al

terin

g th

e qu

antit

y of

cat

alys

t use

d.

For

appl

icat

ions

falli

ng o

utsi

de o

f thi

s te

mpe

ratu

re r

ange

, ple

ase

cont

act y

our

loca

l Flo

wcr

ete

Tech

nica

l Dep

artm

ent.

Deckshield ED is a low VOC, solvent free, flexible, crack-bridging, waterproof polyurethane car park deck coating.

Typically used to cosmetically enhance and protect external and multi-storey car parks.

Deckshield UV (WB)

Deckshield Oxide0.8–1.2mm ScatterDeckshield

Finish

Deckshield ED Membrane

DeckshieldED Primer

Prepared Substrate

Technical Profile

FIRE RESISTANCE

EN 13501–1 B – s1

SLIP RESISTANCE

Method described in AS4586–2013

Dry & Wet Rating isdependant on specification(in accordance with AS4586–2013)

The slipperiness of flooring materials can change significantly, due to the installation process, after short periods of use, due to inappropriatemaintenance, longer-term wear and/or surface contaminants (wet or dry).

Textured systems are recommended to meet slip resistance value requirements for wet conditions and/or surface contaminants (wet or dry) — please contact our Technical Advisors for further details.

TEMPERATURE RESISTANCE

Softens over 70°C Hardens on Cooling

WATER PERMEABILITY

Karsten Nil (Impermeable)

RESISTANCE TO CHLORIDE IONS

DOT BD47/94: Appendix BMethod B4, 2 (d)

No chloride ion penetration after 28 days.

BOND STRENGTH

ASTM D4541 (Pull-Off Test) >1.5MPa*

ABRASION RESISTANCE

Taber Abrader 300mg loss per 1000 cycles 1kg load using CS17 wheels

CRACK-BRIDGING

BS EN 1062–7 Method B1 0.5mm

UV LIGHT RESISTANT

Excellent (Non Yellowing)

SPEED OF CURE** 10˚C 20˚C 30˚C

Light Traffic 30 hrs 18 hrs 12 hrs

Full Traffic 48 hrs 36 hrs 24 hrs

Full Chemical Cure 12 days 7 days 6 days

Crack-Bridging: Conforms to UNE-EN 1062–7:2004Method B — B.3.2

Waterproof: Water resistant and waterproof trafficable deck coating system.

Chemical Resistant: Excellent resistance to engine oil, battery acid, fuel and hydraulic fluid.

UV Light Stable: 100% UV light stable and resistant, non-yellowing

Chemical Resistance

Petrol 9

Diesel 9

Antifreeze 9

Hydraulic Fluid 9

Chlorides 9

Battery Acids 9

Deckshield ED(2.5mm)

*Assumes concrete compressive strength is greater than 25 N/mm2

These figures are typically properties achieved in laboratory tests at 20°C and at 50% Relative Humidity.

Page 7: DECKSHIELD - Flowcrete Australia · Deckshield Range Technical Profile Application Suitability Product Selector Multi-storey car parks have always been many customers’ first point
Page 8: DECKSHIELD - Flowcrete Australia · Deckshield Range Technical Profile Application Suitability Product Selector Multi-storey car parks have always been many customers’ first point

Deckshield ID Rapide(2.5mm)

Technical Profile

FIRE RESISTANCE

EN 13501–1 C – s1

SLIP RESISTANCE

Method described in AS4586–2013

Dry & Wet Rating isdependant on specification(in accordance with AS4586–2013)

The slipperiness of flooring materials can change significantly, due to the installation process, after short periods of use, due to inappropriatemaintenance, longer-term wear and/or surface contaminants (wet or dry).

Textured systems are recommended to meet slip resistance value requirements for wet conditions and/or surface contaminants (wet or dry) — please contact our Technical Advisors for further details.

WATER PERMEABILITY

Karsten Test Nil (Impermeable)

RESISTANCE TO CHLORIDE IONS

DOT BD47/94: Appendix B Method B4,2 (d)

No chloride ion penetration after 28 days

BOND STRENGTH

ASTM D4541 (Pull-Off Test) >1.5 MPa*

ABRASION RESISTANCE

Taber Abrader 300mg loss per 1000 cycles 1kg load using CS17 wheels

CHEMICAL RESISTANT

Contact Technical Department. Resistant to petrol, diesel, antifreeze, hydraulic fluid, chlorides and battery acids.

SPEED OF CURE** PER COAT

Walk on 1 hr

Full Traffic & Chemical Cure 2–3 hrs**

Cur

e tim

es a

t tem

pera

ture

s be

twee

n 0–

30˚C

can

be

achi

eved

by

alte

ring

the

quan

tity

of c

atal

yst u

sed.

Fo

r ap

plic

atio

ns fa

lling

out

side

of t

his

tem

pera

ture

ran

ge, p

leas

e co

ntac

t you

r lo

cal F

low

cret

e Te

chni

cal D

epar

tmen

t.

Deckshield ID Rapide is a flexible MMA car park deck coating system providing a colourful, durable and rapid curing finish.

Typically used to enhance and protect multi-storey car parks and suspended floors.

Rapid Curing: Fast track application, dramatically reducing program time.

Noise Reduction: Higher textured finishes reduce tyre squeal.

Colourful: Aesthetically attractive to brighten dark, dull car parks.

Resistant: Provides fire, slip, abrasion and chemical resistance

Deckshield Rapide Topcoat

Deckshield Oxide / Quartz

Deckshield Rapide/Flowfast

Bodycoat

Silica Quartz Scatter

Deckshield Rapide / Flowfast Damp Primer

Prepared Substrate

Chemical Resistance

Petrol 9

Diesel 9

Antifreeze 9

Hydraulic Fluid 9

Chlorides 9

Battery Acids 9

*Assumes concrete compressive strength is greater than 25 N/mm2

These figures are typically properties achieved in laboratory tests at 20°C and at 50% Relative Humidity.

Page 9: DECKSHIELD - Flowcrete Australia · Deckshield Range Technical Profile Application Suitability Product Selector Multi-storey car parks have always been many customers’ first point
Page 10: DECKSHIELD - Flowcrete Australia · Deckshield Range Technical Profile Application Suitability Product Selector Multi-storey car parks have always been many customers’ first point
Page 11: DECKSHIELD - Flowcrete Australia · Deckshield Range Technical Profile Application Suitability Product Selector Multi-storey car parks have always been many customers’ first point

Deckshield ED Rapide(4mm)

** C

ure

times

at t

empe

ratu

res

betw

een

0–30

˚C c

an b

e ac

hiev

ed b

y al

terin

g th

e qu

antit

y of

cat

alys

t use

d.

For

appl

icat

ions

falli

ng o

utsi

de o

f thi

s te

mpe

ratu

re r

ange

, ple

ase

cont

act y

our

loca

l Flo

wcr

ete

Tech

nica

l Dep

artm

ent.

Deckshield ED Rapide is a flexible MMA car park deck coating providing a colourful, watertight, durable surface for exposed decks.

Typically used to cosmetically enhance and protect external and multi-storey car parks.

Technical Profile

FIRE RESISTANCE

EN 13501–1 C – s1

SLIP RESISTANCE

Method described in AS4586–2013

Dry & Wet isdependant on specification(in accordance with AS4586–2013)

The slipperiness of flooring materials can change significantly, due to the installation process, after short periods of use, due to inappropriatemaintenance, longer-term wear and/or surface contaminants (wet or dry).

Textured systems are recommended to meet slip resistance value requirements for wet conditions and/or surface contaminants (wet or dry) — please contact our Technical Advisors for further details.

WATER PERMEABILITY

Karsten Test Nil (Impermeable)

RESISTANCE TO CHLORIDE IONS

DOT BD47/94: Appendix B Method B4, 2 (d)

No chloride ion penetration after 28 days.

BOND STRENGTH

ASTM D4541 (Pull-Off Test) >1.5MPa*

ABRASION RESISTANCE

Taber Abrader 300mg loss per 1000 cycles 1kg load using CS17 wheels

CRACK-BRIDGING

BS EN 1062–7 Method A Table 6

Class A3 (-20°C)

CHEMICAL RESISTANT

Contact Technical Department. Resistant to petrol, diesel, antifreeze, hydraulic fluid, chlorides and battery acids.

SPEED OF CURE** PER COAT

Walk On 1 hr

Full Traffic & Chemical Cure 2–3 hrs

Rapid Curing: Fast track application, dramatically reducing program time.

Noise Reduction: Higher textured finishes reduce tyre squeal.

Resistant: Provides fire, slip, abrasion and chemical resistance.

Colourful: Aesthetically attractive to brighten dark dull car parks.

Chemical Resistance

Petrol 9

Diesel 9

Antifreeze 9

Hydraulic Fluid 9

Chlorides 9

Battery Acids 9

Deckshield Rapide TopcoatDeckshield

Oxide / QuartzDeckshield Rapide/Flowfast

Bodycoat

Deckshield Rapide

Membrane

Silica Quartz ScatterDeckshield Rapide /

Flowfast Damp PrimerPrepared Substrate

*Assumes concrete compressive strength is greater than 25 N/mm2

These figures are typically properties achieved in laboratory tests at 20°C and at 50% Relative Humidity.

Page 12: DECKSHIELD - Flowcrete Australia · Deckshield Range Technical Profile Application Suitability Product Selector Multi-storey car parks have always been many customers’ first point

Europe & Middle East

Baltic States +48 883 303 880 [email protected]

Bulgaria +359 898 61 58 31 [email protected]

Denmark +46 435 40 01 10 [email protected]

France +33 1 60 61 74 42 [email protected]

Germany +49 4187 50 29 470 [email protected]

Italy +39 339 4853258 [email protected]

Norway +47 6486 0830 [email protected]

Poland +48 22 879 8907 [email protected]

Romania +40 766 596 991 [email protected]

Russia +7 916 931 35 13 [email protected]

Spain +34 937 07 0872 [email protected]

Sweden +46 435 40 01 10 [email protected]

UAE +971 4 886 4728 [email protected]

UK +44 1270 753 000 [email protected]

Africa

East Africa +254 20 682 1011 [email protected]

South Africa +27 31 461 3411 [email protected]

Americas

Brazil +55 11 3230 1107 [email protected]

Canada +1 604 628-1782 [email protected]

Chile +56 2 2938 1962 [email protected]

Colombia +57 1 381 9254 [email protected]

Mexico +01 800 099 0468 [email protected]

USA +1 936 539 6700 [email protected]

India

India +91 44 4202 9831 [email protected]

Flowcrete

World leader in seamless resin flooring solutions and other specialist coatings.

Asia Pacific

Australia +61 7 3205 7115 [email protected]

Bangladesh +88 02 985 7222 [email protected]

China +86 10 8472 1912 [email protected]

Hong Kong +852 2795 0478 [email protected]

Indonesia +62 21 252 3201 [email protected]

Malaysia +60 3 6277 9575 [email protected]

Pakistan +92 33 731 59272 [email protected]

Philippines +63 2 834 6506 [email protected]

Singapore +65 6848 7166 [email protected]

Taiwan +886 916 954 291 [email protected]

Thailand +66 2539 3424 [email protected]

Vietnam +84 8 6287 0846 [email protected]

www.flowcreteaustralia.com.au