Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
Davco K10 GRS 2000
Chua Boon HweeApril 2012
2
Green Roof/ Roof Garden
Traditional Flat Roof
• An building element that is forgotten• Can be a multi-function element that is environmentally friendly and
aestheically appealling• Green Roof/ Roof Garden
Green Roof System
3
Green Roof SystemThe strong urbanisation and increasing shortage of green places in cities push more and more designers to choose architectural solutions that create more green zones to recover areas otherwise lost, thus bettering the aesthetic and living qualities of many building areas.
Advantages
4
Advantages of Green Roof System
High Water Retention
Air Quality Improvement Extends life of the Roof
Reduction of NoiseThermal Insulation
Davco K10 GRS 2000
5
Davco K10 GRS 2000 (Green Roof Membrane)
• Davco GRS 2000 is a specially formulated liquid applied root resistance waterproofing membrane, which contains ‘PREVENTOL B2’, a special additive by BAYER which acts as a chemical barrier to prevent the membrane being perforated by vegetation.
Preventol B2
6
PEVENTOL B2 BY BAYER• Preventol B2 offers long term protection to vegetated
roof because it prevents plant roots from growing into the waterproof membrane and causing leakage.
• Based on its Biological effect, Preventol® B2 redirects roots as they approach the membrane, without damaging/ harming or killing them.
Preventol B2
7
PEVENTOL B2: Properties• Protects building materials from root
penetration.• Has a long-term effect since it is virtually
insoluble in water, non-volatile and non-leachable.
• Remains effective even under extreme weather conditions.
• Has a root-resistant effect even at a very low concentration and is therefore particularly cost-effective.
Root Resistance Testing
• Lupine Test Din 4062 (Germany)– Test-plant: Lupines (lupinus albus), approx.
30-40/ flower-pot– 6 months test
• FLL (2008) Test– 2 years test– 8 tests against perforations caused by roots
and rhizomes
8
Lupines Test
9
Root Resistance DIN 4062 (Lupine test)
Root penetration Well protected
FLL Testing
10
• FLL (2008) Test– 2 years test carried out in
accordance with the “Method of testing resistance to root damage to flexible sheets and coating of roof planting.
– In order to prevent damage, protection sheet and coatings are required to perform permanent resistance against penetration or perforation by plant roots and plant rhizomes (subterranean sprouts).
Davco K10 GRS 2000
11
Davco Green Roof System Comprises of:
•Davco Green Roof System(GRS) 2000•A specially formulated root inhibitor, liquid applied waterproofing membrane
•Separation/ Protection Felt•Provides mechanical protection to anti-root waterproofing membrane.
12
•Davco Drainage Cell•Retain water in the profiled cells, even on sloping roof. Excess water are drains away through the channel between the cell.
•Separation Felt / Filter Membrane•To prevent fine particles being washed out of the substrate soil and therefore maintaining the efficiency of the drainage layer.
Davco Green Roof System Comprises of:
13
•Growing Medium•The selection of medium, depth, type of soil and plants should be carefully chosen based upon local varieties of plant and climatic conditions.
•Davco Insulated Panel•Provides protection to waterproofing membrane and insulation to the concrete roof.
Davco Green Roof System Comprises of:
LIQUID APPLIED MEMBRANE- GRS 2000
Davco K10 GRS 2000•Bitumen Polyurethane
•>80% Solid Content
•Black
•Concealed
•Moisture-cured
•Root Resistance Properties (with Preventol B2)
Polyurethane System
14ParexDavco Waterproofing Products
15
Davco GRS 2000: Features
•High Longer Lasting Performance•Less Wastages•Seamless•Easy to apply•Fully bonded membrane•Flexibility in design considerations
16
Davco GRS 2000: Technical Specifications
•High Solid Content•High Performance
•Elongation •Tensile•Tensile with reinforcement
•Root Resistance testing has been on going > 5 Years
•Meet Hydrostatic Test Requirements•Chemical Resistance•Algae and Fungus Resistance
TechnicalComparision
17
Technical Comparison against Preformed Membrane
Properties PVC Torch On GRS 2000Solid Content 100% 100% >85%Bitumen Resistance Yes Yes YesRoot resistance FFL FFL FFLElongation >300% >40% >500%Tensile Strength >15N >4N >5N
LIQUID APPLIED MEMBRANE- GRS 2000
Davco K10 GRS 2000Properties•Passed Root Resistance- Lupine Test
•Without Netting
•Tensile Strength, 2.08 MPa
•Elongation, 510%
•With Netting
•Tensile Strength, 5.58 MPa
•Elongation, 250%
Polyurethane System
18ParexDavco Waterproofing Products
Application
Area Of Application
•Extra over Davco K10 *
•Roof Garden
•Planter Box
•Coverage 1.25 kg/sq.m
19ParexDavco Waterproofing Products
LIQUID APPLIED MEMBRANE- GRS 2000
Panel Plus Roof Garden
Separation Felt
Davco GRS 2000Waterproofing membrane
Growing Medium
Davco Insulated Panel
Drainage Cell
Davco K10 GRS 2000
Polyurethane System
20ParexDavco Waterproofing Products
LIQUID APPLIED MEMBRANE- GRS 2000
Davco K10 GRS 2000
Polyurethane System
21ParexDavco Waterproofing Products
Completed Projects
22
23
THE END