| Confidential/Property of Danfoss Power Electronics| Thursday, 09 September 2010 | 1Presenting Power Electronics
Danfoss Power Electronics
Low cost of ownership using VLTs in Air compressors
One Companyfocused onClimate & Energy
| C onfidential/Property of Danfoss Drives A/S | Thursday, 09 September 2010 | 2
Today‘s discussions
qCost of Compressed Air
qWhy VFD in Air compressors?
qWhat is VFD & its functions?
qVFDs role in Low cost of ownership of compressors
| C onfidential/Property of Danfoss Drives A/S | Thursday, 09 September 2010 | 3
Energy consumptions & CO2 Emissions
Electricity
Gas/Oil
Water
Raw Mat.
Production
Emission
Waste
36% of carbon dioxide (CO2) emissions
•Electricity is 1/3rd contributor to the CO2 emissions…
•Compressor is the back bone of Indian industry & one of the large segment
•Industry focus shifting towards-Energy Efficiency, process etc.,
•However…. Investment decision & Low cost of ownership needs more focus !
| C onfidential/Property of Danfoss Drives A/S | Thursday, 09 September 2010 | 4
•Compressed air is 8 times the cost of electricity
•Scope for Energy saving – However less focus on Cost of ownership.
•Focus is often on lowest “first cost”
Some known facts…
| C onfidential/Property of Danfoss Drives A/S | Thursday, 09 September 2010 | 5
Air compressor Annual Energy Cost
HP
Annual Energy cost in $
Annual Energy cost in INR
Annual Energy cost in INR
50 37,500 1,800,000 18Lacs100 75,000 3,600,000 36 Lacs150 112,500 5,400,000 54 Lacs200 150,000 7,200,000 72 Lacs250 187,500 9,000,000 90 Lacs300 225,000 10,800,000 108 Lacs
| C onfidential/Property of Danfoss Drives A/S | Thursday, 09 September 2010 | 6
n Air compressors-( Screw) are Normal constant torque loads
n Energy saving of 10-25% in a screw compressors with typical Load-Unload cycle.
n In recip. compressors the Energy saving will be ~10%
VFD energy saving possibility
| C onfidential/Property of Danfoss Drives A/S | Thursday, 09 September 2010 | 7
Many options to start Motors- but see the Starting current!
How VFD can be better…
Smooth start & Stop-ensuring minimum
stress on mechanical components-
Minimize maintenance cost
| C onfidential/Property of Danfoss Drives A/S | Thursday, 09 September 2010 | 8
Fixed AC Input
(3ph,415v/50hz)
Variable AC Output
( 0-415v,0-x Hz)
What is AC Drive( VFD)? Soft starter?
Fixed AC Input
(3ph,415v,50hz)
Variable AC Output
| C onfidential/Property of Danfoss Drives A/S | Thursday, 09 September 2010 | 9
Conventional With VFD
How VFD controls the Air compressors?
| C onfidential/Property of Danfoss Drives A/S | Thursday, 09 September 2010 | 10
Drive is a Drive- Save energy…
What is Low cost of Ownership?
| C onfidential/Property of Danfoss Drives A/S | Thursday, 09 September 2010 | 11
Drive is a Drive- Save energy…What is Low cost of Ownership?
nRole of Design/technology of Drive
ØEfficiency/Heat loss, ØHarmonics filter, ØEMC ComplianceØWorking at 50 Deg. & Harsh environment like India
nDrive sizing
ØVFD to be sized based on Motor FLC ( not on kw)ØSF to be considered while selecting the VFD ratingØIf VFD selection is based on kw, there could be an impact on life of VFD and cost of ownership
| C onfidential/Property of Danfoss Drives A/S | Thursday, 09 September 2010 | 12
Drive is a Drive- Save energy…What is Low cost of Ownership?
n Cost of service/ spares/ life timen Service and spares availability
Ø Availability of service within warranty period/outside warranty period
Ø VFD manufacturers back up to End customers Ø Design life of VFDØ Spares availability and spares cost incase the VFD model
become obsolete
nUse of relevant features of drives for efficient operationnIntegrations/interface with compressors
ØImportant to understand the compressor operations, configure VFD to deliver optimized performanceØOptimal fine tuning of PID is essentialØSpeed windows, minimal speed optimization etc., to be tunedØConfigure VFD display as compressor monitor tool- Set pressure, Line pressure, Energy consumed in Kwh, Hours of operations, Temperature ( all the display in single screen simultaneously)
| C onfidential/Property of Danfoss Drives A/S | Thursday, 09 September 2010 | 13
Drive construction-configurations
| C onfidential/Property of Danfoss Drives A/S | Thursday, 09 September 2010 | 14
Choose the right productfor harsh environment
The drive should performfor decades…
| C onfidential/Property of Danfoss Drives A/S | Thursday, 09 September 2010 | 15
Protection class IP 55 / IP 66
n Can be installed directly at site without need of additional panel.
n All cast aluminium parts are powder coated with a strong epoxy coating.
n The corrosion resistance are tested with detergents commonly used in the industry.
IP66
| C onfidential/Property of Danfoss Drives A/S | Thursday, 09 September 2010 | 16
No need of large panels to house the drive with separate SFU & wires….
The modular technology platform
n Easy component accessibility from the frontn Side by side mountingn Simple replacement of modular sub-assemblies
n Shared features and user interface
Cost saving( for 110kw)Panel :~Rs.15000/-Space :~ 1sq.mtrAccessories :~ Rs.6000/-
| C onfidential/Property of Danfoss Drives A/S | Thursday, 09 September 2010 | 17
Environment
| C onfidential/Property of Danfoss Drives A/S | Thursday, 09 September 2010 | 18
Need to address Indian aggressive environment
Special coated PCBs as standard
•To increase the lifetime the PCB’s can be conformal coated according to IEC61721-3-3.
•There are several levels of conformal coating described in the IEC norm.
•Most of the drives offered are without any coating and some time it is offered as 3C2 Coating.
9,03,01,00,50,1mg/m3Nitrogen Oxides
0,30,10,10,050,01mg/m3Ozone
35103,01,00,3mg/m3Ammonia
2,00,10,030,010,003mg/m3Hydrogen Fluoride
5,01,00,50,10,01mg/m3Hydrogen Chloride
1,00,30,30,10,01mg/m3Chlorine
103,00,50,10,01mg/m3Hydrogen Sulphide
105,01,00,30,1mg/m3Sulphur dioxide
Salt mistSalt mistNomg/m3Sea salt
Max
value
Mean
value
Max
value
Mean
value
3C33C23C1
ClassUnitEnvironment Parameter in aggressive environment•No premature
failure of Drives due to the harsh environment.
| C onfidential/Property of Danfoss Drives A/S | Thursday, 09 September 2010 | 19
Harmonic performance
| C onfidential/Property of Danfoss Drives A/S | Thursday, 09 September 2010 | 20
Multiples, mainly the 5th & 7th harmonics of the fundamental sine wave (50Hz),caused bythe switching current flow through theVFD’s input rectifiers, causes interference inthe incoming power.
Fundamental -sine wave
Summation of all harmonic
frequencies
Harmonic Distortion
n Harmonic Current Distortion increases the RMS current and can result in overheating of the supply transformer and cables.
n Harmonic Voltage Distortion can interfere with other equipment attached to the same line.
n Total Harmonic Distortion (THD) at the point of common coupling is discussed in IEEE 5-19.
Both DC reactors and AC reactors give similar reduction in harmonics but AC reactor has 3% voltage dropVoltage – harmonic filter solutions
HARMONIC CURRENT ANALYSIS------------------------------------------------Fund. Current 36.22 ATHD 42.51%RMS current 39.47 A
5’th Harmonic 12.91 A7’th Harmonic 7.03 A11’th Harmonic 3.06 A13’th Harmonic 2.10 A------------------------------------------------
HARMONIC CURRENT ANALYSIS------------------------------------------------Fund. Current 36.22 ATHD 42.51%RMS current 39.47 A
5’th Harmonic 12.91 A7’th Harmonic 7.03 A11’th Harmonic 3.06 A13’th Harmonic 2.10 A------------------------------------------------
DC reactors
HARMONIC CURRENT ANALYSIS------------------------------------------------Fund. Current 36.84 ATHD 43.84%RMS current 40.22 A
5’th Harmonic 14.71 A7’th Harmonic 5.74 A11’th Harmonic 2.66 A13’th Harmonic 1.34 A------------------------------------------------
HARMONIC CURRENT ANALYSIS------------------------------------------------Fund. Current 36.84 ATHD 43.84%RMS current 40.22 A
5’th Harmonic 14.71 A7’th Harmonic 5.74 A11’th Harmonic 2.66 A13’th Harmonic 1.34 A------------------------------------------------
AC reactors
ac-coilsInverter Inverter
dc-coils
Most times, AC line chokes are not supplied
| C onfidential/Property of Danfoss Drives A/S | Thursday, 09 September 2010 | 23
Harmonic performance
n DC-coils are built-in standard
n Reduced installation cost
n Smaller transformer and cables
n VLT® complies with IEC 61000, generating less than 44% THiD (Below 40%)
Actual comparison on Harmonics control-Both drives have harmonic filters- Result?
x make= THDI 45.15% (full load)x make = THDI 76.34% (50% load)
Tested with EMC test software V2.32b / PAS15000 by Spi tzenberger + Spies GmbH & Co. KG, Schmidstr 32-34, D-94234 Viechtach, 14.06.2006
DC 2 4 6 8 10 12 14 16 18
I/A
0
0.5
1
1.5
2
2.5
3
3.5HARMONIC ANALYSIS: Test FAIL in Timewindow 1 of 469
Y make = THDI 43.33% (full load)Y make = THDI 70.92% (50% load)
Power F
actor=
0.91
Power Facto
r=0.9
1
| C onfidential/Property of Danfoss Drives A/S | Thursday, 09 September 2010 | 25
EMC/ RFI performance
| C onfidential/Property of Danfoss Drives A/S | Thursday, 09 September 2010 | 26
Best built-in EMC performance
n 3 levels filtering available, complies IEC 61800-3
n Screened Cable length up to 150m and 300m unscreened
n Flexibility to meet different requirements
n Eliminates interference with other installed equipment
| C onfidential/Property of Danfoss Drives A/S | Thursday, 09 September 2010 | 27
Energy efficiency
| C onfidential/Property of Danfoss Drives A/S | Thursday, 09 September 2010 | 28
Energy optimization
nAutomatic Energy Optimization (AEO)
n Better system efficiency
n Additional energy savings 3-5%
n Optimised o/p wrt Load
Lowest cost of ownership
Graph Lowest cost of ownership
Voltage
Speed
Annual cost difference on heatloss
Example: Drive at the size of 30kW
Difference = 504W (46%)
Working :24 hours x 360days Energy cost :Rs.5/kWh
Annual cost of excess Heat loss :Rs.21,772/-
Plus the extra costs for cooling……..
You could save Rs.21,000
for 30kw drive/yr
•Reputed make VFD Heat Loss = 1074W
•Make-2 Heat Loss = 570W
| C onfidential/Property of Danfoss Drives A/S | Thursday, 09 September 2010 | 30
Example:Drive at the size of 75kW
Reputed make2 -75kw VFD Heat Loss = 1974W Danfoss VLT Automation Drive FC302 75kw Heat Loss = 1384W
Difference = 590W (~30%)In terms of cost/ yearWorking :24 hours x 360days Energy cost :Rs.5/kWh Annual cost of excess Heat loss :Rs.25,488/-
Plus the extra costs for cooling……..
You could save Rs.25488/-
for 75kw drive/yr
Annual cost difference on heatloss
Heat loss difference in 315kw drive cost you 1.15L/year
VFD make- XX• Heat loss: 8,650 W• + 44 % more heat loss
or 2,659 W
VFD make- YY• Heat loss: 5,991
WCosts……..• Energy costs: 1,000 W • Rs.5/-• Operational hours: 24hrs/365 days• ~Rs.100,000 per year
Additional Costs……..• Air Conditioning requirement for control room.
§ Every kW of losses requires another 0.5 kW of energy to remove the heat
You could save Rs.100,000 +
Rs.15,000per drive/yr
Heat dissipation- Drain your money indirectly
Hea
t lo
ss in W
atts
3 x 400V
Different make VFD kw
0
2000
4000
6000
8000
10000
Loss in watts
37 45 55 75 90 110 132 160 200 250 315 355
KW
HEAT LOSS COMPARISIONDanfoss ABB
61,714 74,022 91,761 110,595 117,822 38,325 28,689 7,402 47,216 40,208 24,046 Annual loss /rating in Rs
| C onfidential/Property of Danfoss Drives A/S | Thursday, 09 September 2010 | 34
No AC requirement and lowest cooling cost
Save-85%
| C onfidential/Property of Danfoss Drives A/S | Thursday, 09 September 2010 | 35
Save: 15.3lacs AC energy bill + 3.6lacs of AC unit cost
80% heat is taken out of Panel Room
Example:No.of drives :10 noTotal Kw : 6300kwHeat loss : 126kwHeat taken out of Panel Room : 107kwHeatloss in Panel Room : 19kw
Cost saving :AC cost saving :Floor space saving:
| C onfidential/Property of Danfoss Drives A/S | Thursday, 09 September 2010 | 36
Motor friendly
| C onfidential/Property of Danfoss Drives A/S | Thursday, 09 September 2010 | 37
Effective motor protection
nElectronic overload protection to ensure Motor protection
nThermistor input for Motor over heat protection
nMotor pre-heat for winter season start up
nIncreased motor life
| C onfidential/Property of Danfoss Drives A/S | Thursday, 09 September 2010 | 38
Some Motor friendly VFDs can work reliable with any standard motor
•The operation of the control and regulation section produces a very clean waveform going to the motor.
•The more sinusoidal the wave form going to the motor the easier it is on the motor and the less heat resulting in longer motor life.
Unique Motor friendly algorithm
| C onfidential/Property of Danfoss Drives A/S | Thursday, 09 September 2010 | 39
User friendly display to saves add on meter cost
| C onfidential/Property of Danfoss Drives A/S | Thursday, 09 September 2010 | 40
Energy monitoring•Built-in energy measurement tool
• Helps user to track record of the energy
• Identifies energy improvement possibilities
• Maintenance & operation instructions support through LCP
•2 Stage password to protect sensitive data
| C onfidential/Property of Danfoss Drives A/S | Thursday, 09 September 2010 | 41
Real time clock- Built in Intelligence
| C onfidential/Property of Danfoss Drives A/S | Thursday, 09 September 2010 | 42
Real Time Clock for compressor maintenance by VFD
n20 actions can be triggered
n Eliminates need for external timers
n Increased flexibility
n Ideal for retrofit applications
nHelps planned system maintenance
Clock example
| Confidential/Property of Danfoss Power Electronics| Thursday, 09 September 2010 | 43Presenting Danfoss Power Electronics
•Established in 1998 as 100% subsidiary
•Indian operation focus in
üManufacturing,üProject Engineering,üMarketing,üSales & MarketingüTraining
•10 sales & service offices across India
•25 sales/service network to support customers
•Dedicated sales network focusing on
üIndustry –Mining, Chemical etc.,üTextile üF&B, üHVAC, üWater
Danfoss India
| Confidential/Property of Danfoss Power Electronics| Thursday, 09 September 2010 | 44Presenting Danfoss Power Electronics
Solutions Ready:VLT® Drives Electronic motor control
n A frequency converter controls electric motors so they only run at the speed necessary to obtain the desired effect
n Electronic motor control can typically save half the energy in pump and fan applications
n Today, only 8% of all electric motors globally are frequency controlled
n Products
n Frequency converters
n Soft starters
n Accessories
26milliontons is the annual CO2reduction
made by the 2.4 million Danfoss frequency converters installed worldwide
| Confidential/Property of Danfoss Power Electronics| Thursday, 09 September 2010 | 45Presenting Danfoss Power Electronics
Production in Europe, USA and China
Denmark
Graasten
Germany
Schleswig
USA
Loves Park, IL
Milwaukee, WI
China
Haiyan, Zhejiang Province
| Confidential/Property of Danfoss Power Electronics| Thursday, 09 September 2010 | 46Presenting Danfoss Power Electronics
Solution example:Danfoss Turbocor compressors
n Danfoss Turbocor is the first high-efficiency, oil-free, variable speed, centrifugal compressor that can provide extremely high energy savings for HVAC systems
n It can reduce up to 35%-50% the energy consumption of a commercial HVAC system
n Today, less than 1% of buildings globally have HVAC systems with high-efficiency, oil-free, variable speed compressors!
400,000Cars removed from the road
is the CO2 equivalent emission savings of the current installedbase of Danfoss Turbocorcompressors worldwide
Thank you