DAF System. Air Supply Pressurizing Pump Retention Tank Flotation Chamber. SKEMATIK PROSES DAF. DAF Configuration. Full Flow Pressurization Partial Flow Pressurization Recycle Flow Pressurization. Full Flow Pressurization. - PowerPoint PPT Presentation

Citation preview

Page 1: DAF System

DAF System Air Supply Pressurizing Pump Retention Tank Flotation Chamber

Page 2: DAF System

SKEMATIK PROSES DAF

Page 3: DAF System
Page 4: DAF System

DAF Configuration

Full Flow Pressurization Partial Flow Pressurization Recycle Flow

Pressurization

Page 5: DAF System

Full Flow Pressurization

The entire influent feed stream is pressurized by a pressurizing pump and held in the retention tank

The system is usually applicable to the feed stream with suspended solids exceeding 800 mg/L in concentration

It is not susceptible to the shearing effects caused by the pressurizing pump and the high pressure drop at the pressure release valve

Suspended solids will flocculate rapidly with the addition of chemical coagulants in the inlet compartment in the presence of the released air

Page 6: DAF System

Partial Flow Pressurization

Only about 30–50% of the influent feed stream is pressurized by a high-pressure pump and held in the retention tank.

Materials with low specific gravity can be removed with the partial flow pressurization system.

The increased hydraulic flow on the flotation chamber due to the flow recirculation must be taken into account in the flotation chamber design.

Page 7: DAF System

Recycle Flow Pressurization

A portion (15–50%) of the clarified effluent from the flotation chamber is recycled, pressurized, and semisaturated with air in the retention tank.

The system is usually employed in applications where preliminary chemical addition and flocculation are necessary ahead of flotation.

This system is not recommended for use when the suspended solids are susceptible to the shearing effects of the pressurizing pump and the high-pressure drop at the pressure release valve.

The suspended solids concentrations are low.

Page 8: DAF System

Faktor-Faktor Yang Mempengaruhi Kinerja DAF

Sifat Partikel Ukuran Partikel Dispersing Agents Komposisi dan sifat Influent Arus Cairan Rasio A/S Float Removal

Page 9: DAF System

Sifat Partikel

The specific gravity is a characteristic of the particle or liquid to be abated or separated.

It can easily be accepted that sand, for example, cannot be floated while voluminous material, such as activated sludge, or a water immiscible liquid such as oil, can be floated.

Page 10: DAF System

Ukuran Partikel

Generally, floatability increases with the size of the particle.

In many cases,the size of particles can be increased by flocculation with various chemical coagulants.

Page 11: DAF System

Dispersing Agents

Certain wastewaters and liquids contain unusual concentrations of various chemicals, resulting in specific flotation problems or advantages.

Surfactants, such as detergents, tend to alter the physical properties of the sludge particle surface to be floated.

Page 12: DAF System

Komposisi dan sifat Influent

The composition and nature of the influent is most important.

Equalization of composition and flow improves the performance of the flotation unit.

Page 13: DAF System

Arus Cairan

The liquid currents are governed by the physical design and hydraulics of the flotation unit.

This becomes a consideration in the design of the tank and hydraulic loadings of the flotation unit.

Page 14: DAF System

Rasio A/S

The amount of air and the method of mixing the air with the material to be floated are functions of the design of a particular flotation unit.

For a specific application, a definite amount of air is necessary for flotation.

In thickening applications it has been shown that increased performance is obtained at higher A/S ratios.

Page 15: DAF System

Air to Solids Ratio

Page 16: DAF System

Float Removal

A float-removal mechanism must be designed to have adequate capacity to remove water carryover.

Various items to be considered in this design are the depth of submergence of the scooping mechanism and the speed of scoop operation.

Page 17: DAF System

Gas to Solids Ratio : Full Flow Pressurized System

QCr

QCe

G

QCfX

G

Gin Gout

Henry’s law

Correction factor, F or f, because complete gas saturation of liquid is often not achieved in a pressurized retention tank

f = 0,167 – 1,0

F = 0,5 – 1,0P ≥ 2 atmP < 2 atm

Page 18: DAF System

Gas to Solids Ratio : Partial Flow Pressurized System

QpCr

QCe

G

QCfX

G

Gin Gout

f = 0,167 – 1,0

F = 0,5 – 1,0P ≥ 2 atmP < 2 atm

QnCf

The Qp/Q ratio ranges between 0.3 and 0.5

Page 19: DAF System

Gas to Solids Ratio : Recycle Flow Pressurized System

f = 0,167 – 1,0

F = 0,5 – 1,0P ≥ 2 atmP < 2 atm

QrCr

QCe

G

QCfX

G

GinGout

R = Qr/Q

Page 20: DAF System

Air Solubility in Water at 1 Atm (a)

0 5 10 15 20 25 30 35 400

5

10

15

20

25

30

35

Temperature, oC

Air S

olub

ility

, ml/L

Temp. oC Air Sol. (mL/L)0 28,810 23,520 20,130 17,9

Page 21: DAF System

Air Characteristics and Solubilities

Page 22: DAF System

Pressure Calculations

Page 23: DAF System

Design Parameters

Hydraulic loading rate Solids loading rate Air to Solids ratio Retention Tank Pressure

Page 24: DAF System

Basic Design Concept

VH = horizontal velocity (m/s), Q = influent flow rate (m3/s), Ac = cross-sectional area of a flotation chamber (m2)VT = vertical rise rate of suspended solids (m/s), D = effective depth of the flotation chamber (m), T = detention time (s), Q = influent flow rate (m3/s), AS = surface area of flotation chamber (m2)

The ratio of Q/Asis also defined as the hydraulic loading rate

Page 25: DAF System

Basic Design Concept

The D/W ratio is usually between 0.3 and 0.5 F′= factor for short circuiting and turbulence, assumed

as 1.4.

D = effective depth (m)W = effective width (m)L = effective length (m)

Page 26: DAF System

The influence of Loading Rate

Page 27: DAF System

DAF Operation and Performance

Page 28: DAF System