2
Options for series D2.xxx Ordering note: The ordering number for the gauge has four digit ordering codes added to it: e.g. DRD 160/211.811/…/0013 (0013: connection M20 x 1,5). Numbers above 9000 are explained in clear. Component Special designs Ordering Bourdon tube Diaphragm Code Nominal size Nominal size 100 160 100 160 Ring Polished 0106 X A A Case Air- and watertight IP 67 0114 X X X Splash watertight IP 54 0115 X X X Movement Gauge lower than measuring point 9206 X X X X Gauge higher than measuring point 9206 X X X X Gauge Gauge higher than measuring point 9207 X X X X Meas. element overpressure protection plus-side 0201 X X underpressure protection minus-side 0203 X X Connection Connection G 1 /2 0004 X X for flat sealing M20 u 1,5 0013 X Connection tapered, 1 /2–14 NPT 0024 X X X self-sealing Custom-made connections 9020 A A A A Dial Red sector 9695 X X X X Green sector 9696 X X X X Red markings at … 9700 X X X X Green markings at … 9701 X X X X Indication range (measuring range) 9704 X X X X identical/similar to catalog sheet however, different measuring units (for ex. kp/cm2 instead of bar) Indication range (measuring range) 9705 X X X X identical to catalog sheet however, different graduation (for ex. 0 … 7.3 t instead of 0 … 10 bar) Indication range (measuring range) 9709 X X X X identical to catalog sheet dial design as per specification Measuring range (indication range) 9210 X X X X not according to catalog (for ex. 0 … 20 bar, –1 … 20 bar) Company logo 9710 X X X X Technical print 9711 X X X X Window Laminated safety glass 0751 X X X Polycarbonate (macrolon) 0753 X www.baumerprocess.com Data Sheet A 25 D2.901 Design and specifications subject to change without notice Page 1

D2 901 Option UK

Embed Size (px)

Citation preview

Page 1: D2 901 Option UK

Options for series D2.xxx

Ordering note:The ordering number for the gauge has four digit ordering codes added to it:

e.g. DRD 160/211.811/…/0013 (0013: connection M20 x 1,5). Numbers above 9000 are explained in clear.

Component Special designs Ordering Bourdon tube Diaphragm Code Nominal size Nominal size 100 160 100 160

Ring Polished 0106 – X A A Case

Air- and watertight IP 67 0114 – X X X Splash watertight IP 54 0115 – X X X Movement

Gauge lower than measuring point 9206 X X X X Gauge higher than measuring point 9206 X X X XGauge

Gauge higher than measuring point 9207 X X X X Meas. element

overpressure protection plus-side 0201 – – X X underpressure protection minus-side 0203 – – X X Connection

Connection G1/2 0004 – – X X for flat sealing M20 u 1,5 0013 – X – –

Connection tapered, 1/2–14 NPT 0024 – X X X

self-sealing Custom-made connections 9020 A A A A

Dial Red sector 9695 X X X X Green sector 9696 X X X X Red markings at … 9700 X X X X Green markings at … 9701 X X X X

Indication range (measuring range) 9704 X X X X identical/similar to catalog sheet however, different measuring units (for ex. kp/cm2 instead of bar)

Indication range (measuring range) 9705 X X X X identical to catalog sheet however, different graduation (for ex. 0 … 7.3 t instead of 0 … 10 bar)

Indication range (measuring range) 9709 X X X X identical to catalog sheet dial design as per specification Measuring range (indication range) 9210 X X X X not according to catalog (for ex. 0 … 20 bar, –1 … 20 bar)

Company logo 9710 X X X X Technical print 9711 X X X X Window

Laminated safety glass 0751 X X X Polycarbonate (macrolon) 0753 X – – –

www.baumerprocess.com Data Sheet A 25 D2.901

Design and specifications subject to change without notice Page 1

Page 2: D2 901 Option UK

UK

/200

7-08

-16

Thi

s da

ta s

heet

may

onl

y be

rep

rodu

ced

in fu

ll.

Component Special designs Ordering Bourdon tube Diaphragm Code Nominal size Nominal size 100 160 100 160

Safety precautions Explosion hole(s) with cover 0760 – X X X Measuring element oil- and grease-free 0765 – X X X Helium leak test 0792 – X X X (leaking rate < 10–6 mbar • I • s–1) Screws secured with «Lock-Tite» 0799 – X X X Throttle screw drilling ø 0.5 (brass) 0771 X X – –

Case prepared for liquid filling 0773 – X X X

Case with dampening liquid 86% 0774 – X X X glycerine ( 25 … 60 °C)

Case with dampening liquid 99.5% 0775 – X X X glycerine (5 … 60 °C)

Case with dampening liquid AK 100 0776 – X X X silicone oil (–35 … 60 °C)

Case with dampening liquid 0777 – X X X paraffin oil ( –10 … 60 °C)

Certificates Factory Certificate 2.1 • X X X X Faktory test report 2.2 • X X X X

Calibration Certificate (not official) • X X X X

Notes:

• order as text

A on request

www.baumerprocess.com Data Sheet A 25 D2.901

Design and specifications subject to change without notice Page 2