Cryostat and Magnet Status Report UIUC

EDM Collaboration Meeting

LANL

June 20, 2005

Page 2: Cryostat and Magnet Status Report UIUC EDM Collaboration Meeting LANL June 20, 2005

Summary

• Cryostat Goals• Progress• To Do

• Magnet Goals• Current Field

Measurements• Future Field

Measurements

Page 3: Cryostat and Magnet Status Report UIUC EDM Collaboration Meeting LANL June 20, 2005

Crysostat goals

• Ensure no cryostat materials spoil magnetic field uniformity.

• Minimize heat load.

Page 4: Cryostat and Magnet Status Report UIUC EDM Collaboration Meeting LANL June 20, 2005

Cryostat Progress

• Large 3He cell constructed, cleaned and purity-tested with a spectrometer

• Silicon-Bronze selected as replacement for inner vacuum vessel flange.

• Indium seals selected to replace conflat seals

Page 5: Cryostat and Magnet Status Report UIUC EDM Collaboration Meeting LANL June 20, 2005

Long 3He cell

Page 6: Cryostat and Magnet Status Report UIUC EDM Collaboration Meeting LANL June 20, 2005

Cryostat to Do

• Replace dewar (currently being ordered)

• Completely rework outside plumbing

• Build new inner vacuum vessel

• Pumping lines (3He and 4He) must be replaced with thinner walled steel to reduce heat load

• Test/Install large 3He cell

Page 7: Cryostat and Magnet Status Report UIUC EDM Collaboration Meeting LANL June 20, 2005

Magnet Design

• Ensure B/B <5E-5 cm-1 over VOI by optimizing coil currents and spacings.

• Coil currents determined by number of windings and shunt resistors.

• Coil diameters are identical.

Page 8: Cryostat and Magnet Status Report UIUC EDM Collaboration Meeting LANL June 20, 2005

First measurement with Gantry

•First attempted to map coils with “gantry” from G0 project

•Long term variation of order 0.1 G in the probe offsets rendered this data useless for determining gradient information

Page 9: Cryostat and Magnet Status Report UIUC EDM Collaboration Meeting LANL June 20, 2005

Current center field measurement

-0.08-0.07-0.06-0.05-0.04-0.03-0.02-0.01

00.010.02

0 50 100 150 200 250 300 350

Position (cm)

Fie

ld D

evia

tio

n (

G)

Deviation from 5 Gauss, measured with Fluxgate magnetometer

Page 10: Cryostat and Magnet Status Report UIUC EDM Collaboration Meeting LANL June 20, 2005

Current field measurement• Several gradients appear in the data, one of

order 2*10-5 cm-1 and one of order 10-4 cm-1.• Location of change in gradient value

corresponds with junction of two PVC tubes used to position fluxgate.

• Fluxgate has time dependences that could not be completely removed.

• More accurate positioning and a more precise field measurement are necessary.

Page 11: Cryostat and Magnet Status Report UIUC EDM Collaboration Meeting LANL June 20, 2005

Next field uniformity measurement

• ~0.1 mG magneto-resistive sensor purchased

• To be mounted on boom of G0 mapper